Sample records for direct detection rate

  1. Adding Endoscopist-Directed Flexible Endoscopic Evaluation of Swallowing to the Videofluoroscopic Swallowing Study Increased the Detection Rates of Penetration, Aspiration, and Pharyngeal Residue.

    PubMed

    Park, Won Young; Lee, Tae Hee; Ham, Nam Seok; Park, Ji Woong; Lee, Yang Gyun; Cho, Sang Jin; Lee, Joon Seong; Hong, Su Jin; Jeon, Seong Ran; Kim, Hyun Gun; Cho, Joo Young; Kim, Jin Oh; Cho, Jun Hyung; Lee, Ji Sung

    2015-09-23

    Currently, the videofluoroscopic swallowing study (VFSS) is the standard tool for evaluating dysphagia. We evaluated whether the addition of endoscopist-directed flexible endoscopic evaluation of swallowing (FEES) to VFSS could improve the detection rates of penetration, aspiration, and pharyngeal residue, compared the diagnostic efficacy between VFSS and endoscopist-directed FEES and assessed the adverse events of the FEES. In single tertiary referral center, a retrospective analysis of prospectively collected data was conducted. Fifty consecutive patients suspected of oropharyngeal dysphagia were enrolled in this study between January 2012 and July 2012. The agreement in the detection of penetration and aspiration between VFSS and FEES of viscous food (κ=0.34; 95% confidence interval [CI], 0.15 to 0.53) and liquid food (κ=0.22; 95% CI, 0.02 to 0.42) was "fair." The agreement in the detection of pharyngeal residue between the two tests was "substantial" with viscous food (κ=0.63; 95% CI, 0.41 to 0.94) and "fair" with liquid food (κ=0.37; 95% CI, 0.10 to 0.63). Adding FEES to VFSS significantly increased the detection rates of penetration, aspiration, and pharyngeal residue. No severe adverse events were noted during FEES, except for two cases of epistaxis, which stopped spontaneously without requiring any packing. This study demonstrated that the addition of endoscopist-directed FEES to VFSS increased the detection rates of penetration, aspiration, and pharyngeal residue.

  2. Utilisation of a direct access echocardiography service by general practitioners in a remote and rural area--distance and rurality are not barriers to referral.

    PubMed

    Choo, Wai K; McGeary, Katie; Farman, Colin; Greyling, Andre; Cross, Stephen J; Leslie, Stephen J

    2014-01-01

    This study aimed to examine whether general practitioner (GP) practice locations in remote and rural areas affected the pattern of direct access echocardiography referral and to assess any variations in echocardiographic findings. All referrals made by all GP practices in the Scottish Highlands over a 36-month period were analysed. Referral patterns were examined according to distance and rurality based on the Scottish Government's Urban-Rural Classification. Reasons for referral and cardiac abnormality detection rates were also examined. In total, 1188 referrals were made from 49 different GP practices; range of referral rates was 0.3-20.1 per 1000 population with a mean of 6.5 referrals per 1000 population. Referral rates were not significantly different between urban and rural practices after correction for population size. There was no correlation between the referral rates and the distance from the centre (r2=0.004, p=0.65). The most common reason for referral was the presence of new murmur (46%). The most common presenting symptom was breathlessness (44%). Overall, 28% of studies had significant abnormal findings requiring direct input from a cardiologist. There was no clear relationship between referral rates and cardiac abnormality detection rates (r2=0.07, p=0.37). The average cardiac abnormality detection rate was 56%, (range 52-60%), with no variation based on rurality (p=0.891). In this cohort, rurality and distance were not barriers to an equitable direct access echocardiography service. Cardiac abnormality detection rates are consistent with that of other studies.

  3. A comparison of directed search target detection versus in-scene target detection in Worldview-2 datasets

    NASA Astrophysics Data System (ADS)

    Grossman, S.

    2015-05-01

    Since the events of September 11, 2001, the intelligence focus has moved from large order-of-battle targets to small targets of opportunity. Additionally, the business community has discovered the use of remotely sensed data to anticipate demand and derive data on their competition. This requires the finer spectral and spatial fidelity now available to recognize those targets. This work hypothesizes that directed searches using calibrated data perform at least as well as inscene manually intensive target detection searches. It uses calibrated Worldview-2 multispectral images with NEF generated signatures and standard detection algorithms to compare bespoke directed search capabilities against ENVI™ in-scene search capabilities. Multiple execution runs are performed at increasing thresholds to generate detection rates. These rates are plotted and statistically analyzed. While individual head-to-head comparison results vary, 88% of the directed searches performed at least as well as in-scene searches with 50% clearly outperforming in-scene methods. The results strongly support the premise that directed searches perform at least as well as comparable in-scene searches.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozorgnia, Nassim; Gelmini, Graciela B.; Gondolo, Paolo, E-mail: n.bozorgnia@uva.nl, E-mail: gelmini@physics.ucla.edu, E-mail: paolo@physics.utah.edu

    Directional dark matter detection attempts to measure the direction of motion of nuclei recoiling after having interacted with dark matter particles in the halo of our Galaxy. Due to Earth's motion with respect to the Galaxy, the dark matter flux is concentrated around a preferential direction. An anisotropy in the recoil direction rate is expected as an unmistakable signature of dark matter. The average nuclear recoil direction is expected to coincide with the average direction of dark matter particles arriving to Earth. Here we point out that for a particular type of dark matter, inelastic exothermic dark matter, the meanmore » recoil direction as well as a secondary feature, a ring of maximum recoil rate around the mean recoil direction, could instead be opposite to the average dark matter arrival direction. Thus, the detection of an average nuclear recoil direction opposite to the usually expected direction would constitute a spectacular experimental confirmation of this type of dark matter.« less

  5. Effect of hydrodynamical-simulation–inspired dark matter velocity profile on directional detection of dark matter

    DOE PAGES

    Laha, Ranjan

    2018-02-01

    Directional detection is an important way to detect dark matter. An input for these experiments is the dark matter velocity distribution. Recent hydrodynamical simulations have shown that the dark matter velocity distribution differs substantially from the Standard Halo Model. We study the impact of some of these updated velocity distributions in dark matter directional detection experiments. Here, we calculate the ratio of events required to confirm the forward-backward asymmetry and the existence of the ring of maximum recoil rate using different dark matter velocity distributions for 19F and Xe targets. We show that with the use of updated dark mattermore » velocity profiles, the forward-backward asymmetry and the ring of maximum recoil rate can be confirmed using a factor of ~ 2– 3 less events when compared to that using the Standard Halo Model.« less

  6. Effect of hydrodynamical-simulation–inspired dark matter velocity profile on directional detection of dark matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laha, Ranjan

    Directional detection is an important way to detect dark matter. An input for these experiments is the dark matter velocity distribution. Recent hydrodynamical simulations have shown that the dark matter velocity distribution differs substantially from the Standard Halo Model. We study the impact of some of these updated velocity distributions in dark matter directional detection experiments. Here, we calculate the ratio of events required to confirm the forward-backward asymmetry and the existence of the ring of maximum recoil rate using different dark matter velocity distributions for 19F and Xe targets. We show that with the use of updated dark mattermore » velocity profiles, the forward-backward asymmetry and the ring of maximum recoil rate can be confirmed using a factor of ~ 2– 3 less events when compared to that using the Standard Halo Model.« less

  7. Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

    PubMed

    Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L

    2017-08-15

    In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.

  8. AntiparticleDM: Discriminating between Majorana and Dirac Dark Matter

    NASA Astrophysics Data System (ADS)

    Kavanagh, Bradley J.; Queiroz, Farinaldo S.; Rodejohann, Werner; Yaguna, Carlos E.

    2018-02-01

    AntiparticleDM calculates the prospects of future direct detection experiments to discriminate between Majorana and Dirac Dark Matter (i.e., to determine whether Dark Matter is its own antiparticle). Direct detection event rates and mock data generation are dealt with by a variation of the WIMpy code.

  9. Cost and detection rate of glaucoma screening with imaging devices in a primary care center

    PubMed Central

    Anton, Alfonso; Fallon, Monica; Cots, Francesc; Sebastian, María A; Morilla-Grasa, Antonio; Mojal, Sergi; Castells, Xavier

    2017-01-01

    Purpose To analyze the cost and detection rate of a screening program for detecting glaucoma with imaging devices. Materials and methods In this cross-sectional study, a glaucoma screening program was applied in a population-based sample randomly selected from a population of 23,527. Screening targeted the population at risk of glaucoma. Examinations included optic disk tomography (Heidelberg retina tomograph [HRT]), nerve fiber analysis, and tonometry. Subjects who met at least 2 of 3 endpoints (HRT outside normal limits, nerve fiber index ≥30, or tonometry ≥21 mmHg) were referred for glaucoma consultation. The currently established (“conventional”) detection method was evaluated by recording data from primary care and ophthalmic consultations in the same population. The direct costs of screening and conventional detection were calculated by adding the unit costs generated during the diagnostic process. The detection rate of new glaucoma cases was assessed. Results The screening program evaluated 414 subjects; 32 cases were referred for glaucoma consultation, 7 had glaucoma, and 10 had probable glaucoma. The current detection method assessed 677 glaucoma suspects in the population, of whom 29 were diagnosed with glaucoma or probable glaucoma. Glaucoma screening and the conventional detection method had detection rates of 4.1% and 3.1%, respectively, and the cost per case detected was 1,410 and 1,435€, respectively. The cost of screening 1 million inhabitants would be 5.1 million euros and would allow the detection of 4,715 new cases. Conclusion The proposed screening method directed at population at risk allows a detection rate of 4.1% and a cost of 1,410 per case detected. PMID:28243057

  10. Direct detection of light dark matter and solar neutrinos via color center production in crystals

    NASA Astrophysics Data System (ADS)

    Budnik, Ranny; Cheshnovsky, Ori; Slone, Oren; Volansky, Tomer

    2018-07-01

    We propose a new low-threshold direct-detection concept for dark matter and for coherent nuclear scattering of solar neutrinos, based on the dissociation of atoms and subsequent creation of color center type defects within a lattice. The novelty in our approach lies in its ability to detect single defects in a macroscopic bulk of material. This class of experiments features ultra-low energy thresholds which allows for the probing of dark matter as light as O (10) MeV through nuclear scattering. Another feature of defect creation in crystals is directional information, which presents as a spectacular signal and a handle on background reduction in the form of daily modulation of the interaction rate. We discuss the envisioned setup and detection technique, as well as background reduction. We further calculate the expected rates for dark matter and solar neutrinos in two example crystals for which available data exists, demonstrating the prospective sensitivity of such experiments.

  11. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    PubMed

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary analysis showed similar results. Based on these findings, a paired cohort study enrolling at least 257 men would verify whether this difference is statistically significant. The diagnostic ability of software-based targeted biopsy and visually directed targeted biopsy seems almost comparable, although utility and efficiency both seem to be slightly in favor of the software-based strategy. Ongoing trials are sufficiently powered to prove or disprove these findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Tactile functions after cerebral hemispherectomy.

    PubMed

    Backlund, H; Morin, C; Ptito, A; Bushnell, M C; Olausson, H

    2005-01-01

    Patients that were hemispherectomized due to brain lesions early in life sometimes have remarkably well-preserved tactile functions on their paretic body half. This has been attributed to developmental neuroplasticity. However, the tactile examinations generally have been fairly crude, and subtle deficits may not have been revealed. We investigated monofilament detection and three types of tactile directional sensibility in four hemispherectomized patients and six healthy controls. Patients were examined bilaterally on the face, forearm and lower leg. Normal subjects were examined unilaterally. Following each test of directional sensibility, subjects were asked to rate the intensity of the stimulation. On the nonparetic side, results were almost always in the normal range. On the paretic side, the patients' capacity for monofilament detection was less impaired than their directional sensibility. Despite the disturbed directional sensibility on their paretic side the patients rated tactile sensations evoked by the stimuli, on both their paretic and nonparetic body halves, as more intense than normals. Thus, mechanisms of plasticity seem adequate for tactile detection and intensity coding but not for more complex tactile functions such as directional sensibility. The reason for the high vulnerability of tactile directional sensibility may be that it depends on spatially and temporally precise afferent information processed in a distributed cortical network.

  13. Optical spectral sweep comb liquid flow rate sensor.

    PubMed

    Shen, Changyu; Lian, Xiaokang; Kavungal, Vishnu; Zhong, Chuan; Liu, Dejun; Semenova, Yuliya; Farrell, Gerald; Albert, Jacques; Donegan, John F

    2018-02-15

    In microfluidic chip applications, the flow rate plays an important role. Here we propose a simple liquid flow rate sensor by using a tilted fiber Bragg grating (TFBG) as the sensing element. As the water flows in the vicinity of the TFBG along the fiber axis direction, the TFBG's spectrum changes due to its contact with water. By comparing the time-swept spectra of the TFBG in water to that of the TFBG with water flowing over it, a spectral sweep comb was formed, and the flow rate can be detected by selecting a suitable sweeping frequency. The proposed sensor has a high Q-value of over 17,000 for the lower rate and a large detectable range from 0.0058 mm/s to 3.2 mm/s. And the calculated corresponding lower detectable flow rate of 0.03 nL/s is 3 orders magnitude better than that of the current fiber flowmeter. Meanwhile, the proposed sensor has the temperature self-compensation function for the variation of the external temperature. We believe that this simple configuration will open a research direction of the TFBG-deriving theory and configuration for lower flow rate measurements for microfluidic chip applications.

  14. Direct-detected rapid-scan EPR at 250 MHz

    NASA Astrophysics Data System (ADS)

    Stoner, James W.; Szymanski, Dennis; Eaton, Sandra S.; Quine, Richard W.; Rinard, George A.; Eaton, Gareth R.

    2004-09-01

    EPR spectra at 250 MHz for a single crystal of lithium phthalocyanine (LiPc) in the absence of oxygen and for a deoxygenated aqueous solution of a Nycomed triarylmethyl (trityl-CD 3) radical were obtained at scan rates between 1.3 × 10 3 and 3.4 × 10 5 G/s. These scan rates are rapid relative to the reciprocals of the electron spin relaxation times (LiPc: T1=3.5 μs and T2=2.5 μs; trityl: T1=12 μs and T2=11.5 μs) and cause characteristic oscillations in the direct-detected absorption spectra. For a given scan rate, shorter values of T2 and increased inhomogeneous broadening cause less deep oscillations that damp out more quickly than for longer T2. There is excellent agreement between experimental and calculated lineshapes and signal amplitudes as a function of radiofrequency magnetic field ( B1) and scan rate. When B1 is adjusted for maximum signal amplitude as a function of scan rate, signal intensity for constant number of scans is enhanced by up to a factor of three relative to slow scans. The number of scans that can be averaged in a defined period of time is proportional to the scan rate, which further enhances signal amplitude per unit time. Longer relaxation times cause the maximum signal intensity to occur at slower scan rates. These experiments provide the first systematic characterization of direct-detected rapid-scan EPR signals.

  15. [Detection of Clonorchis sinensis eggs in the ground gallbladder stones by microscopy].

    PubMed

    Ma, Rui-Hong; Qiao, Tie; Luo, Xiao-Bing

    2012-08-30

    Sera, feces, bile and gallbladder stones were collected from 179 patients who accepted gallbladder-preserving cholelithotomy during the period of January to June 2010 at the general surgery department in the Second People's Hospital of Panyu District in Guangzhou. Rapid colloidal gold immunochromatography was used to detect IgG against Clonorchis sinensis. C. sinensis eggs were examined by fecal direct smear, and in bile sediments and ground gallbladder stones. The results showed that the positive rate of rapid colloidal gold immunochromatographic assay for IgG was 51.4%, and the egg positive rate in feces, bile sediments and gallbladder stones was 30.7%, 44.7% and 69.8%, respectively. The detection rate of fecal direct smear was the lowest, while that of the gallbladder stone examination was the highest (P < 0.05). Those patients with egg-positive feces and/or bile sediments were all with egg-positive gallbladder stones.

  16. Signatures of Earth-scattering in the direct detection of Dark Matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kavanagh, Bradley J.; Catena, Riccardo; Kouvaris, Chris, E-mail: bkavanagh@lpthe.jussieu.fr, E-mail: catena@chalmers.se, E-mail: kouvaris@cp3.sdu.dk

    Direct detection experiments search for the interactions of Dark Matter (DM) particles with nuclei in terrestrial detectors. But if these interactions are sufficiently strong, DM particles may scatter in the Earth, affecting their distribution in the lab. We present a new analytic calculation of this 'Earth-scattering' effect in the regime where DM particles scatter at most once before reaching the detector. We perform the calculation self-consistently, taking into account not only those particles which are scattered away from the detector, but also those particles which are deflected towards the detector. Taking into account a realistic model of the Earth andmore » allowing for a range of DM-nucleon interactions, we present the EARTHSHADOW code, which we make publicly available, for calculating the DM velocity distribution after Earth-scattering. Focusing on low-mass DM, we find that Earth-scattering reduces the direct detection rate at certain detector locations while increasing the rate in others. The Earth's rotation induces a daily modulation in the rate, which we find to be highly sensitive to the detector latitude and to the form of the DM-nucleon interaction. These distinctive signatures would allow us to unambiguously detect DM and perhaps even identify its interactions in regions of the parameter space within the reach of current and future experiments.« less

  17. Optimized velocity distributions for direct dark matter detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ibarra, Alejandro; Rappelt, Andreas, E-mail: ibarra@tum.de, E-mail: andreas.rappelt@tum.de

    We present a method to calculate, without making assumptions about the local dark matter velocity distribution, the maximal and minimal number of signal events in a direct detection experiment given a set of constraints from other direct detection experiments and/or neutrino telescopes. The method also allows to determine the velocity distribution that optimizes the signal rates. We illustrate our method with three concrete applications: i) to derive a halo-independent upper limit on the cross section from a set of null results, ii) to confront in a halo-independent way a detection claim to a set of null results and iii) tomore » assess, in a halo-independent manner, the prospects for detection in a future experiment given a set of current null results.« less

  18. Dark matter direct detection of a fermionic singlet at one loop

    NASA Astrophysics Data System (ADS)

    Herrero-García, Juan; Molinaro, Emiliano; Schmidt, Michael A.

    2018-06-01

    The strong direct detection limits could be pointing to dark matter - nucleus scattering at loop level. We study in detail the prototype example of an electroweak singlet (Dirac or Majorana) dark matter fermion coupled to an extended dark sector, which is composed of a new fermion and a new scalar. Given the strong limits on colored particles from direct and indirect searches we assume that the fields of the new dark sector are color singlets. We outline the possible simplified models, including the well-motivated cases in which the extra scalar or fermion is a Standard Model particle, as well as the possible connection to neutrino masses. We compute the contributions to direct detection from the photon, the Z and the Higgs penguins for arbitrary quantum numbers of the dark sector. Furthermore, we derive compact expressions in certain limits, i.e., when all new particles are heavier than the dark matter mass and when the fermion running in the loop is light, like a Standard Model lepton. We study in detail the predicted direct detection rate and how current and future direct detection limits constrain the model parameters. In case dark matter couples directly to Standard Model leptons we find an interesting interplay between lepton flavor violation, direct detection and the observed relic abundance.

  19. PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites.

    PubMed

    Gerwin, Philip M; Ricart Arbona, Rodolfo J; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S

    2017-11-01

    We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite-infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method.

  20. PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites

    PubMed Central

    Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S

    2017-01-01

    We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite- infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method. PMID:29256370

  1. Auditory integration training for children with autism: no behavioral benefits detected.

    PubMed

    Mudford, O C; Cross, B A; Breen, S; Cullen, C; Reeves, D; Gould, J; Douglas, J

    2000-03-01

    Auditory integration training and a control treatment were provided for 16 children with autism in a crossover experimental design. Measures, blind to treatment order, included parent and teacher ratings of behavior, direct observational recordings, IQ, language, and social/adaptive tests. Significant differences tended to show that the control condition was superior on parent-rated measures of hyperactivity and on direct observational measures of ear-occlusion. No differences were detected on teacher-rated measures. Children's IQs and language comprehension did not increase, but adaptive/social behavior scores and expressive language quotients decreased. The majority of parents (56%) were unable to report in retrospect when their child had received auditory integration training. No individual child was identified as benefiting clinically or educationally from the treatment.

  2. Infrared small target detection based on directional zero-crossing measure

    NASA Astrophysics Data System (ADS)

    Zhang, Xiangyue; Ding, Qinghai; Luo, Haibo; Hui, Bin; Chang, Zheng; Zhang, Junchao

    2017-12-01

    Infrared small target detection under complex background and low signal-to-clutter ratio (SCR) condition is of great significance to the development on precision guidance and infrared surveillance. In order to detect targets precisely and extract targets from intricate clutters effectively, a detection method based on zero-crossing saliency (ZCS) map is proposed. The original map is first decomposed into different first-order directional derivative (FODD) maps by using FODD filters. Then the ZCS map is obtained by fusing all directional zero-crossing points. At last, an adaptive threshold is adopted to segment targets from the ZCS map. Experimental results on a series of images show that our method is effective and robust for detection under complex backgrounds. Moreover, compared with other five state-of-the-art methods, our method achieves better performance in terms of detection rate, SCR gain and background suppression factor.

  3. The artful dodger: answering the wrong question the right way.

    PubMed

    Rogers, Todd; Norton, Michael I

    2011-06-01

    What happens when speakers try to "dodge" a question they would rather not answer by answering a different question? In 4 studies, we show that listeners can fail to detect dodges when speakers answer similar-but objectively incorrect-questions (the "artful dodge"), a detection failure that goes hand-in-hand with a failure to rate dodgers more negatively. We propose that dodges go undetected because listeners' attention is not usually directed toward a goal of dodge detection (i.e., Is this person answering the question?) but rather toward a goal of social evaluation (i.e., Do I like this person?). Listeners were not blind to all dodge attempts, however. Dodge detection increased when listeners' attention was diverted from social goals toward determining the relevance of the speaker's answers (Study 1), when speakers answered a question egregiously dissimilar to the one asked (Study 2), and when listeners' attention was directed to the question asked by keeping it visible during speakers' answers (Study 4). We also examined the interpersonal consequences of dodge attempts: When listeners were guided to detect dodges, they rated speakers more negatively (Study 2), and listeners rated speakers who answered a similar question in a fluent manner more positively than speakers who answered the actual question but disfluently (Study 3). These results add to the literatures on both Gricean conversational norms and goal-directed attention. We discuss the practical implications of our findings in the contexts of interpersonal communication and public debates.

  4. Pinning down inelastic dark matter in the Sun and in direct detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blennow, Mattias; Clementz, Stefan; Herrero-Garcia, Juan, E-mail: emb@kth.se, E-mail: scl@kth.se, E-mail: juhg@kth.se

    2016-04-01

    We study the solar capture rate of inelastic dark matter with endothermic and/or exothermic interactions. By assuming that an inelastic dark matter signal will be observed in next generation direct detection experiments we can set a lower bound on the capture rate that is independent of the local dark matter density, the velocity distribution, the galactic escape velocity as well as the scattering cross section. In combination with upper limits from neutrino observatories we can place upper bounds on the annihilation channels leading to neutrinos. We find that, while endothermic scattering limits are weak in the isospin-conserving case, strong boundsmore » may be set for exothermic interactions, in particular in the spin-dependent case. Furthermore, we study the implications of observing two direct detection signals, in which case one can halo-independently obtain the dark matter mass and the mass splitting, and disentangle the endothermic/exothermic nature of the scattering. Finally we discuss isospin violation.« less

  5. Direct detection of sub-GeV dark matter with semiconductor targets

    DOE PAGES

    Essig, Rouven; Fernández-Serra, Marivi; Mardon, Jeremy; ...

    2016-05-09

    Dark matter in the sub-GeV mass range is a theoretically motivated but largely unexplored paradigm. Such light masses are out of reach for conventional nuclear recoil direct detection experiments, but may be detected through the small ionization signals caused by dark matter-electron scattering. Semiconductors are well-studied and are particularly promising target materials because their O(1 eV) band gaps allow for ionization signals from dark matter particles as light as a few hundred keV. Current direct detection technologies are being adapted for dark matter-electron scattering. In this paper, we provide the theoretical calculations for dark matter-electron scattering rate in semiconductors, overcomingmore » several complications that stem from the many-body nature of the problem. We use density functional theory to numerically calculate the rates for dark matter-electron scattering in silicon and germanium, and estimate the sensitivity for upcoming experiments such as DAMIC and SuperCDMS. We find that the reach for these upcoming experiments has the potential to be orders of magnitude beyond current direct detection constraints and that sub-GeV dark matter has a sizable modulation signal. We also give the first direct detection limits on sub-GeV dark matter from its scattering off electrons in a semiconductor target (silicon) based on published results from DAMIC. We make available publicly our code, QEdark, with which we calculate our results. Our results can be used by experimental collaborations to calculate their own sensitivities based on their specific setup. In conclusion, the searches we propose will probe vast new regions of unexplored dark matter model and parameter space.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blennow, Mattias; Herrero-Garcia, Juan; Schwetz, Thomas, E-mail: emb@kth.se, E-mail: juhg@kth.se, E-mail: schwetz@fysik.su.se

    We show that a positive signal in a dark matter (DM) direct detection experiment can be used to place a lower bound on the DM capture rate in the Sun, independent of the DM halo. For a given particle physics model and DM mass we obtain a lower bound on the capture rate independent of the local DM density, velocity distribution, galactic escape velocity, as well as the scattering cross section. We illustrate this lower bound on the capture rate by assuming that upcoming direct detection experiments will soon obtain a significant signal. When comparing the lower bound on themore » capture rate with limits on the high-energy neutrino flux from the Sun from neutrino telescopes, we can place upper limits on the branching fraction of DM annihilation channels leading to neutrinos. With current data from IceCube and Super-Kamiokande non-trivial limits can be obtained for spin-dependent interactions and direct annihilations into neutrinos. In some cases also annihilations into ττ or b b start getting constrained. For spin-independent interactions current constraints are weak, but they may become interesting for data from future neutrino telescopes.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blennow, Mattias; Herrero-Garcia, Juan; Schwetz, Thomas

    We show that a positive signal in a dark matter (DM) direct detection experiment can be used to place a lower bound on the DM capture rate in the Sun, independent of the DM halo. For a given particle physics model and DM mass we obtain a lower bound on the capture rate independent of the local DM density, velocity distribution, galactic escape velocity, as well as the scattering cross section. We illustrate this lower bound on the capture rate by assuming that upcoming direct detection experiments will soon obtain a significant signal. When comparing the lower bound on themore » capture rate with limits on the high-energy neutrino flux from the Sun from neutrino telescopes, we can place upper limits on the branching fraction of DM annihilation channels leading to neutrinos. With current data from IceCube and Super-Kamiokande non-trivial limits can be obtained for spin-dependent interactions and direct annihilations into neutrinos. In some cases also annihilations into ττ or bb start getting constrained. For spin-independent interactions current constraints are weak, but they may become interesting for data from future neutrino telescopes.« less

  8. High-rate x-ray spectroscopy in mammography with a CdTe detector: a digital pulse processing approach.

    PubMed

    Abbene, L; Gerardi, G; Principato, F; Del Sordo, S; Ienzi, R; Raso, G

    2010-12-01

    Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

  9. Manipulation Detection and Preference Alterations in a Choice Blindness Paradigm

    PubMed Central

    Taya, Fumihiko; Gupta, Swati; Farber, Ilya; Mullette-Gillman, O'Dhaniel A.

    2014-01-01

    Objectives It is commonly believed that individuals make choices based upon their preferences and have access to the reasons for their choices. Recent studies in several areas suggest that this is not always the case. In choice blindness paradigms, two-alternative forced-choice in which chosen-options are later replaced by the unselected option, individuals often fail to notice replacement of their chosen option, confabulate explanations for why they chose the unselected option, and even show increased preferences for the unselected-but-replaced options immediately after choice (seconds). Although choice blindness has been replicated across a variety of domains, there are numerous outstanding questions. Firstly, we sought to investigate how individual- or trial-factors modulated detection of the manipulations. Secondly, we examined the nature and temporal duration (minutes vs. days) of the preference alterations induced by these manipulations. Methods Participants performed a computerized choice blindness task, selecting the more attractive face between presented pairs of female faces, and providing a typewritten explanation for their choice on half of the trials. Chosen-face cue manipulations were produced on a subset of trials by presenting the unselected face during the choice explanation as if it had been selected. Following all choice trials, participants rated the attractiveness of each face individually, and rated the similarity of each face pair. After approximately two weeks, participants re-rated the attractiveness of each individual face online. Results Participants detected manipulations on only a small proportion of trials, with detections by fewer than half of participants. Detection rates increased with the number of prior detections, and detection rates subsequent to first detection were modulated by the choice certainty. We show clear short-term modulation of preferences in both manipulated and non-manipulated explanation trials compared to choice-only trials (with opposite directions of effect). Preferences were altered in the direction that subjects were led to believe they selected. PMID:25247886

  10. Towards Accurate Node-Based Detection of P2P Botnets

    PubMed Central

    2014-01-01

    Botnets are a serious security threat to the current Internet infrastructure. In this paper, we propose a novel direction for P2P botnet detection called node-based detection. This approach focuses on the network characteristics of individual nodes. Based on our model, we examine node's flows and extract the useful features over a given time period. We have tested our approach on real-life data sets and achieved detection rates of 99-100% and low false positives rates of 0–2%. Comparison with other similar approaches on the same data sets shows that our approach outperforms the existing approaches. PMID:25089287

  11. Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate

    PubMed Central

    Schuck, Carsten; Pernice, Wolfram H. P.; Tang, Hong X.

    2013-01-01

    Superconducting nanowire single-photon detectors are an ideal match for integrated quantum photonic circuits due to their high detection efficiency for telecom wavelength photons. Quantum optical technology also requires single-photon detection with low dark count rate and high timing accuracy. Here we present very low noise superconducting nanowire single-photon detectors based on NbTiN thin films patterned directly on top of Si3N4 waveguides. We systematically investigate a large variety of detector designs and characterize their detection noise performance. Milli-Hz dark count rates are demonstrated over the entire operating range of the nanowire detectors which also feature low timing jitter. The ultra-low dark count rate, in combination with the high detection efficiency inherent to our travelling wave detector geometry, gives rise to a measured noise equivalent power at the 10−20 W/Hz1/2 level. PMID:23714696

  12. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS

    PubMed Central

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS. PMID:26554930

  13. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS.

    PubMed

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.

  14. In vivo detection of brain Krebs cycle intermediate by hyperpolarized magnetic resonance.

    PubMed

    Mishkovsky, Mor; Comment, Arnaud; Gruetter, Rolf

    2012-12-01

    The Krebs (or tricarboxylic acid (TCA)) cycle has a central role in the regulation of brain energy regulation and metabolism, yet brain TCA cycle intermediates have never been directly detected in vivo. This study reports the first direct in vivo observation of a TCA cycle intermediate in intact brain, namely, 2-oxoglutarate, a key biomolecule connecting metabolism to neuronal activity. Our observation reveals important information about in vivo biochemical processes hitherto considered undetectable. In particular, it provides direct evidence that transport across the inner mitochondria membrane is rate limiting in the brain. The hyperpolarized magnetic resonance protocol designed for this study opens the way to direct and real-time studies of TCA cycle kinetics.

  15. What are incident reports telling us? A comparative study at two Australian hospitals of medication errors identified at audit, detected by staff and reported to an incident system

    PubMed Central

    Westbrook, Johanna I.; Li, Ling; Lehnbom, Elin C.; Baysari, Melissa T.; Braithwaite, Jeffrey; Burke, Rosemary; Conn, Chris; Day, Richard O.

    2015-01-01

    Objectives To (i) compare medication errors identified at audit and observation with medication incident reports; (ii) identify differences between two hospitals in incident report frequency and medication error rates; (iii) identify prescribing error detection rates by staff. Design Audit of 3291patient records at two hospitals to identify prescribing errors and evidence of their detection by staff. Medication administration errors were identified from a direct observational study of 180 nurses administering 7451 medications. Severity of errors was classified. Those likely to lead to patient harm were categorized as ‘clinically important’. Setting Two major academic teaching hospitals in Sydney, Australia. Main Outcome Measures Rates of medication errors identified from audit and from direct observation were compared with reported medication incident reports. Results A total of 12 567 prescribing errors were identified at audit. Of these 1.2/1000 errors (95% CI: 0.6–1.8) had incident reports. Clinically important prescribing errors (n = 539) were detected by staff at a rate of 218.9/1000 (95% CI: 184.0–253.8), but only 13.0/1000 (95% CI: 3.4–22.5) were reported. 78.1% (n = 421) of clinically important prescribing errors were not detected. A total of 2043 drug administrations (27.4%; 95% CI: 26.4–28.4%) contained ≥1 errors; none had an incident report. Hospital A had a higher frequency of incident reports than Hospital B, but a lower rate of errors at audit. Conclusions Prescribing errors with the potential to cause harm frequently go undetected. Reported incidents do not reflect the profile of medication errors which occur in hospitals or the underlying rates. This demonstrates the inaccuracy of using incident frequency to compare patient risk or quality performance within or across hospitals. New approaches including data mining of electronic clinical information systems are required to support more effective medication error detection and mitigation. PMID:25583702

  16. Unexpected Direction of Differential Item Functioning

    ERIC Educational Resources Information Center

    Park, Sangwook

    2011-01-01

    Many studies have been conducted to evaluate the performance of DIF detection methods, when two groups have different ability distributions. Such studies typically have demonstrated factors that are associated with inflation of Type I error rates in DIF detection, such as mean ability differences. However, no study has examined how the direction…

  17. Using Dandelion Flower Stalks for Gravitropic Studies.

    ERIC Educational Resources Information Center

    Clifford, Paul E.; Oxlade, Edwin L.

    1991-01-01

    Activities that use dandelions to show the phenomena of geotropism and autotropism are described. Directions for collecting the stalks and observing the gravitropic response are included. The topics of lag time and bending rates, autotropism, growth rate changes, presentation time, and gravity detection are discussed. (KR)

  18. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    NASA Astrophysics Data System (ADS)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  19. Capacity, cutoff rate, and coding for a direct-detection optical channel

    NASA Technical Reports Server (NTRS)

    Massey, J. L.

    1980-01-01

    It is shown that Pierce's pulse position modulation scheme with 2 to the L pulse positions used on a self-noise-limited direct detection optical communication channel results in a 2 to the L-ary erasure channel that is equivalent to the parallel combination of L completely correlated binary erasure channels. The capacity of the full channel is the sum of the capacities of the component channels, but the cutoff rate of the full channel is shown to be much smaller than the sum of the cutoff rates. An interpretation of the cutoff rate is given that suggests a complexity advantage in coding separately on the component channels. It is shown that if short-constraint-length convolutional codes with Viterbi decoders are used on the component channels, then the performance and complexity compare favorably with the Reed-Solomon coding system proposed by McEliece for the full channel. The reasons for this unexpectedly fine performance by the convolutional code system are explored in detail, as are various facets of the channel structure.

  20. Generation and transmission of DPSK signals using a directly modulated passive feedback laser.

    PubMed

    Karar, Abdullah S; Gao, Ying; Zhong, Kang Ping; Ke, Jian Hong; Cartledge, John C

    2012-12-10

    The generation of differential-phase-shift keying (DPSK) signals is demonstrated using a directly modulated passive feedback laser at 10.709-Gb/s, 14-Gb/s and 16-Gb/s. The quality of the DPSK signals is assessed using both noncoherent detection for a bit rate of 10.709-Gb/s and coherent detection with digital signal processing involving a look-up table pattern-dependent distortion compensator. Transmission over a passive link consisting of 100 km of single mode fiber at a bit rate of 10.709-Gb/s is achieved with a received optical power of -45 dBm at a bit-error-ratio of 3.8 × 10(-3) and a 49 dB loss margin.

  1. CAN IBEX DETECT INTERSTELLAR NEUTRAL HELIUM OR OXYGEN FROM ANTI-RAM DIRECTIONS?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galli, A.; Wurz, P.; Park, J.

    To better constrain the parameters of the interstellar neutral flow, we searched the Interstellar Boundary EXplorer (IBEX)-Lo database for helium and oxygen from the interstellar medium in the anti-ram direction in the three years (2009–2011) with the lowest background rates. We found that IBEX-Lo cannot observe interstellar helium from the anti-ram direction because the helium energy is too low for indirect detection by sputtering off the IBEX-Lo conversion surface. Our results show that this sputtering process has a low energy threshold between 25 and 30 eV, whereas the energy of the incident helium is only 10 eV for these observations.more » Interstellar oxygen, on the other hand, could in principle be detected in the anti-ram hemisphere, but the expected magnitude of the signal is close to the detection limit imposed by counting statistics and by the magnetospheric foreground.« less

  2. Sensitivity of direct immunofluorescence in oral diseases. Study of 125 cases.

    PubMed

    Sano, Susana Mariela; Quarracino, María Cecilia; Aguas, Silvia Cristina; González, Ernestina Jesús; Harada, Laura; Krupitzki, Hugo; Mordoh, Ana

    2008-05-01

    Direct immunofluorescence (DIF) is widely used for the diagnosis of bullous diseases and other autoimmune pathologies such as oral lichen planus. There is no evidence in the literature on how the following variants influence the detection rate of DIF: intraoral site chosen for the biopsy, perilesional locus or distant site from the clinical lesion, number of biopsies and instrument used. to determine if the following variants influenced the sensitivity (detection rate): intraoral site chosen for the biopsy, perilesional or distant site from the clinical lesion, number of biopsies and instrument used (punch or scalpel). A retrospective study was done at the Cátedra de Patología y Clínica Bucodental II at the Facultad de Odontología, Universidad de Buenos Aires; 136 clinical medical histories were revised for the period March 2000 - March 2005 corresponding to patients with clinical diagnosis of OLP and bullous diseases (vulgar pemphigus, bullous pemphigoid and cicatricial pemphigoid). DIF detection rate was 65.8% in patients with OLP, 66.7% in cicatricial pemphigoid patients, in bullous pemphigoid 55.6%, in pemphigus vulgaris 100%, and in those cases in which certain diagnosis could not be obtained, the DIF positivity rate was 45.5% (Pearson chi(2) (4)= 21.5398 Pr= 0.000). There was no statistically significant difference between the different sites of biopsy (Fisher exact test: 0.825). DIF detection rate in perilesional biopsies was 66.1% and in those distant from the site of clinical lesion was 64.7% (Pearson chi(2) v1)= 0.0073 Pr= 0.932. When the number of biopsies were incremented, DIF detection rate also incremented (Pearson chi(2) = 8.7247 Pr= 0.003). The biopsies taken with punch had a higher detection rate than those taken with scalpel (39.1% versus 71.7%) (Pearson chi(2) = 49.0522 Pr= 0.000). While not statistically significant, the tendency outlined in this study indicates there are intraoral regions in which the detection rate of the DIF technique is higher than others: mouth floor, hard palate, superior labial mucosa, ventral face of tongue. This finding could allow a choice of accessible locations and easy operator manipulation, even in distant places from the clinical lesion. Perilesional biopsies have a detection rate similar to those taken distant from the clinical lesion, and those taken with punch have a higher sensitivity rate than those taken with scalpel (both differences were statistically significant).

  3. Direct questioning is more effective than patient-initiated report for the detection of sexually transmitted infections in a primary care HIV clinic in Western Kenya.

    PubMed

    Woo, Victoria Gah Hay; Cohen, Craig R; Bukusi, Elizabeth A; Huchko, Megan J

    2013-02-01

    In resource-limited settings, detection of sexually transmitted infections (STIs) often relies on self-reported symptoms to initiate management. We found self-report demonstrated poor sensitivity for STI detection. Adding clinician-initiated questions about symptoms improved detection rates. Vaginal examination further increased sensitivity. Including clinician-initiated screening in resource-limited settings would improve management of treatable STIs.

  4. Evaluation of Traditional and Contemporary Methods for Detecting Syphacia obvelata and Aspiculuris tetraptera in Laboratory Mice

    PubMed Central

    Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Lepherd, Michelle L; Henderson, Ken S; Lipman, Neil S

    2017-01-01

    There is no consensus regarding the best practice for detecting murine pinworm infections. Initially, we evaluated 7 fecal concentration methods by using feces containing Aspiculuris tetraptera (AT) eggs (n = 20 samples per method). Sodium nitrate flotation, sodium nitrate centrifugation, Sheather sugar centrifugation, and zinc sulfate centrifugation detected eggs in 100% of samples; zinc sulfate flotation and water sedimentation detected eggs in 90%. All had better detection rates than Sheather sugar flotation (50%). To determine optimal detection methods, Swiss Webster mice were exposed to Syphacia obvelata (SO; n = 60) or AT (n = 60). We compared the following methods at days 0, 30, and 90, beginning 21 or 28 d after SO and AT exposure, respectively: fecal concentration (AT only), anal tape test (SO only), direct examination of intestinal contents (cecum and colon), Swiss roll histology (cecum and colon), and PCR analysis (pooled fur swab and feces). Detection rates for SO-exposed mice were: PCR analysis, 45%; Swiss roll histology, 30%; intestinal content exam, 27%; and tape test, 27%. The SO detection rate for PCR analysis was significantly greater than that for the tape test. Detection rates for AT-exposed mice were: intestinal content exam, 53%; PCR analysis, 33%; fecal flotation, 22%; and Swiss roll histology, 17%. The AT detection rate of PCR analysis combined with intestinal content examination was greater than for PCR analysis only and the AT detection rate of intestinal content examination was greater than for Swiss roll histology. Combining PCR analysis with intestinal content examination detected 100% of infected animals. No single test detected all positive animals. We recommend combining PCR analysis with intestinal content examination for optimal pinworm detection. PMID:28905712

  5. Reconstructing WIMP properties through an interplay of signal measurements in direct detection, Fermi-LAT, and CTA searches for dark matter

    NASA Astrophysics Data System (ADS)

    Roszkowski, Leszek; Sessolo, Enrico Maria; Trojanowski, Sebastian; Williams, Andrew J.

    2016-08-01

    We examine the projected ability to reconstruct the mass, scattering, and annihilation cross section of dark matter in the new generation of large underground detectors, XENON-1T, SuperCDMS, and DarkSide-G2, in combination with diffuse gamma radiation from expected 15 years of data from Fermi-LAT observation of 46 local spiral dwarf galaxies and projected CTA sensitivity to a signal from the Galactic Center. To this end we consider several benchmark points spanning a wide range of WIMP mass, different annihilation final states, and large enough event rates to warrant detection in one or more experiments. As previously shown, below some 100 GeV only direct detection experiments will in principle be able to reconstruct WIMP mass well. This may, in case a signal at Fermi-LAT is also detected, additionally help restricting σv and the allowed decay branching rates. In the intermediate range between some 100 GeV and up a few hundred GeV, direct and indirect detection experiments can be used in complementarity to ameliorate the respective determinations, which in individual experiments can at best be rather poor, thus making the WIMP reconstruction in this mass range very challenging. At large WIMP mass, ~ 1 TeV, CTA will have the ability to reconstruct mass, annihilation cross section, and the allowed decay branching rates to very good precision for the τ+τ- or purely leptonic final state, good for the W+W- case, and rather poor for bbar b. A substantial improvement can potentially be achieved by reducing the systematic uncertainties, increasing exposure, or by an additional measurement at Fermi-LAT that would help reconstruct the annihilation cross section and the allowed branching fractions to different final states.

  6. Screen-detected versus interval cancers: Effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme.

    PubMed

    Timmermans, Lore; Bleyen, Luc; Bacher, Klaus; Van Herck, Koen; Lemmens, Kim; Van Ongeval, Chantal; Van Steen, Andre; Martens, Patrick; De Brabander, Isabel; Goossens, Mathieu; Thierens, Hubert

    2017-09-01

    To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration. • Interval cancer rate increases gradually with breast density, regardless of modality. • Cancer detection rate in high-density breasts is superior in DR. • IC rate exceeds CDR for SF and CR in high-density breasts. • DR performs better in high-density breasts for third readings and false-positives.

  7. Multiview road sign detection via self-adaptive color model and shape context matching

    NASA Astrophysics Data System (ADS)

    Liu, Chunsheng; Chang, Faliang; Liu, Chengyun

    2016-09-01

    The multiview appearance of road signs in uncontrolled environments has made the detection of road signs a challenging problem in computer vision. We propose a road sign detection method to detect multiview road signs. This method is based on several algorithms, including the classical cascaded detector, the self-adaptive weighted Gaussian color model (SW-Gaussian model), and a shape context matching method. The classical cascaded detector is used to detect the frontal road signs in video sequences and obtain the parameters for the SW-Gaussian model. The proposed SW-Gaussian model combines the two-dimensional Gaussian model and the normalized red channel together, which can largely enhance the contrast between the red signs and background. The proposed shape context matching method can match shapes with big noise, which is utilized to detect road signs in different directions. The experimental results show that compared with previous detection methods, the proposed multiview detection method can reach higher detection rate in detecting signs with different directions.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, K.; Itow, Y.; Rott, C., E-mail: koun@stelab.nagoya-u.ac.jp, E-mail: rott@skku.edu, E-mail: itow@stelab.nagoya-u.ac.jp

    Dark matter could be captured in the Sun and self-annihilate, giving rise to an observable neutrino flux. Indirect searches for dark matter looking for this signal with neutrino telescopes have resulted in tight constraints on the interaction cross-section of dark matter with ordinary matter. We investigate how robust limits are against astro-physical uncertainties. We study the effect of the velocity distribution of dark matter in our Galaxy on capture rates in the Sun. We investigate four sources of uncertainties: orbital speed of the Sun, escape velocity of dark matter from the halo, dark matter velocity distribution functions and existence ofmore » a dark disc. We find that even extreme cases currently discussed do not decrease the sensitivity of indirect detection significantly because the capture is achieved over a broad range of the velocity distribution by integration over the velocity distribution. The effect of the uncertainty in the high-velocity tail of dark matter halo is very marginal as the capture process is rather inefficient at this region. The difference in capture rate in the Sun for various scenarios is compared to the expected change in event rates for direct detection. The possibility of co-rotating structure with the Sun can largely boost the signal and hence makes the interpretation of indirect detection conservative compared to direct detection.« less

  9. Direct measurement of mammographic X-ray spectra with a digital CdTe detection system.

    PubMed

    Abbene, Leonardo; Gerardi, Gaetano; Principato, Fabio; Del Sordo, Stefano; Raso, Giuseppe

    2012-01-01

    In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1-30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole collimator and a custom alignment device. A comparison with the attenuation curves and the half value layer values, obtained from the measured and simulated spectra, from an ionization chamber and from a solid state dosimeter, also shows the accuracy of the measurements. These results make the proposed detection system a very attractive tool for both laboratory research, calibration of dosimeters and advanced quality controls in mammography.

  10. A Dual-Process Account of Auditory Change Detection

    ERIC Educational Resources Information Center

    McAnally, Ken I.; Martin, Russell L.; Eramudugolla, Ranmalee; Stuart, Geoffrey W.; Irvine, Dexter R. F.; Mattingley, Jason B.

    2010-01-01

    Listeners can be "deaf" to a substantial change in a scene comprising multiple auditory objects unless their attention has been directed to the changed object. It is unclear whether auditory change detection relies on identification of the objects in pre- and post-change scenes. We compared the rates at which listeners correctly identify changed…

  11. In vivo detection of brain Krebs cycle intermediate by hyperpolarized magnetic resonance

    PubMed Central

    Mishkovsky, Mor; Comment, Arnaud; Gruetter, Rolf

    2012-01-01

    The Krebs (or tricarboxylic acid (TCA)) cycle has a central role in the regulation of brain energy regulation and metabolism, yet brain TCA cycle intermediates have never been directly detected in vivo. This study reports the first direct in vivo observation of a TCA cycle intermediate in intact brain, namely, 2-oxoglutarate, a key biomolecule connecting metabolism to neuronal activity. Our observation reveals important information about in vivo biochemical processes hitherto considered undetectable. In particular, it provides direct evidence that transport across the inner mitochondria membrane is rate limiting in the brain. The hyperpolarized magnetic resonance protocol designed for this study opens the way to direct and real-time studies of TCA cycle kinetics. PMID:22990416

  12. A posture recognition based fall detection system for monitoring an elderly person in a smart home environment.

    PubMed

    Yu, Miao; Rhuma, Adel; Naqvi, Syed Mohsen; Wang, Liang; Chambers, Jonathon

    2012-11-01

    We propose a novel computer vision based fall detection system for monitoring an elderly person in a home care application. Background subtraction is applied to extract the foreground human body and the result is improved by using certain post-processing. Information from ellipse fitting and a projection histogram along the axes of the ellipse are used as the features for distinguishing different postures of the human. These features are then fed into a directed acyclic graph support vector machine (DAGSVM) for posture classification, the result of which is then combined with derived floor information to detect a fall. From a dataset of 15 people, we show that our fall detection system can achieve a high fall detection rate (97.08%) and a very low false detection rate (0.8%) in a simulated home environment.

  13. Reaction rates of graphite with ozone measured by etch decoration

    NASA Technical Reports Server (NTRS)

    Hennig, G. R.; Montet, G. L.

    1968-01-01

    Etch-decoration technique of detecting vacancies in graphite has been used to determine the reaction rates of graphite with ozone in the directions parallel and perpendicular to the layer planes. It consists essentially of peeling single atom layers off graphite crystals without affecting the remainder of the crystal.

  14. Second primary cancers after cancer of unknown primary in Sweden and Germany: efficacy of the modern work-up.

    PubMed

    Liu, Hao; Hemminki, Kari; Sundquist, Jan; Holleczek, Bernd; Katalinic, Alexander; Emrich, Katharina; Brenner, Hermann

    2013-05-01

    In unsparing efforts to find the hidden primaries, second primary cancers (SPCs) unrelated to cancer of unknown primary (CUP) are found. The detection rates of SPCs after CUP can be considered as measures for the effectiveness of modern diagnostic techniques in finding tumors. We aimed to compare the rates of specific SPCs found after the work-up of CUP and the more sign/symptom-directed diagnostic approaches applied after any other cancer. The number of CUP patients identified in the nationwide Swedish database and nine German cancer registries was 24 641 from 1997 through 2006, and rate ratios (RRs) for SPCs were recorded in two follow-up periods. The detection rate of SPCs immediately after any other cancer was about two times higher in Germany than in Sweden, but the rate immediately after CUP was almost the same for the two datasets. In the joint analyses after CUP, the RRs of liver, lung, breast, and kidney cancers were higher than after any other cancer, whereas the RRs of prostate, urinary bladder, and connective tissue cancers as well as non-Hodgkin's lymphoma were not significantly different; the RR of cancers of upper aerodigestive tract was lower after CUP than after any other cancer. The joint data indicate that the work-up is efficient in detecting tumors in the thoracoabdominal organs that are screened by computed tomography. For some other organ sites, the more sign/symptom-directed diagnostic approaches may be equally efficient. However, none of the applied techniques could detect all tumors immediately after the first diagnosis.

  15. Standoff detection of turbulent chemical mixture plumes using a swept external cavity quantum cascade laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, Mark C.; Brumfield, Brian E.

    We demonstrate standoff detection of turbulent mixed-chemical plumes using a broadly-tunable external cavity quantum cascade laser (ECQCL). The ECQCL was directed through plumes of mixed methanol/ethanol vapor to a partially-reflective surface located 10 m away. The reflected power was measured as the ECQCL was swept over its tuning range of 930-1065 cm-1 (9.4-10.8 µm) at rates up to 200 Hz. Analysis of the transmission spectra though the plume was performed to determine chemical concentrations with time resolution of 0.005 s. Comparison of multiple spectral sweep rates of 2 Hz, 20 Hz, and 200 Hz shows that higher sweep rates reducemore » effects of atmospheric and source turbulence, resulting in lower detection noise and more accurate measurement of the rapidly-changing chemical concentrations. Detection sensitivities of 0.13 ppm*m for MeOH and 1.2 ppm*m for EtOH are demonstrated for a 200 Hz spectral sweep rate, normalized to 1 s detection time.« less

  16. Effect of gravitational focusing on annual modulation in dark-matter direct-detection experiments.

    PubMed

    Lee, Samuel K; Lisanti, Mariangela; Peter, Annika H G; Safdi, Benjamin R

    2014-01-10

    The scattering rate in dark-matter direct-detection experiments should modulate annually due to Earth's orbit around the Sun. The rate is typically thought to be extremized around June 1, when the relative velocity of Earth with respect to the dark-matter wind is maximal. We point out that gravitational focusing can alter this modulation phase. Unbound dark-matter particles are focused by the Sun's gravitational potential, affecting their phase-space density in the lab frame. Gravitational focusing can result in a significant overall shift in the annual-modulation phase, which is most relevant for dark matter with low scattering speeds. The induced phase shift for light O(10)  GeV dark matter may also be significant, depending on the threshold energy of the experiment.

  17. Impact of changing from staining to culture techniques on detection rates of Campylobacter spp. in routine stool samples in Chile.

    PubMed

    Porte, Lorena; Varela, Carmen; Haecker, Thomas; Morales, Sara; Weitzel, Thomas

    2016-05-13

    Campylobacter is a leading cause of bacterial gastroenteritis, but sensitive diagnostic methods such as culture are expensive and often not available in resource limited settings. Therefore, direct staining techniques have been developed as a practical and economical alternative. We analyzed the impact of replacing Campylobacter staining with culture for routine stool examinations in a private hospital in Chile. From January to April 2014, a total of 750 consecutive stool samples were examined in parallel by Hucker stain and Campylobacter culture. Isolation rates of Campylobacter were determined and the performance of staining was evaluated against culture as the gold standard. Besides, isolation rates of Campylobacter and other enteric pathogens were compared to those of past years. Campylobacter was isolated by culture in 46 of 750 (6.1 %) stool samples. Direct staining only identified three samples as Campylobacter positive and reached sensitivity and specificity values of 6.5 and 100 %, respectively. In comparison to staining-based detection rates of previous years, we observed a significant increase of Campylobacter cases in our patients. Direct staining technique for Campylobacter had a very low sensitivity compared to culture. Staining methods might lead to a high rate of false negative results and an underestimation of the importance of campylobacteriosis. With the inclusion of Campylobacter culture, this pathogen became a leading cause of intestinal infection in our patient population.

  18. NASA direct detection laser diode driver

    NASA Technical Reports Server (NTRS)

    Seery, B. D.; Hornbuckle, C. A.

    1989-01-01

    TRW has developed a prototype driver circuit for GaAs laser diodes as part of the NASA/Goddard Space Flight Center's Direct Detection Laser Transceiver (DDLT) program. The circuit is designed to drive the laser diode over a range of user-selectable data rates from 1.7 to 220 Mbps, Manchester-encoded, while ensuring compatibility with 8-bit and quaternary pulse position modulation (QPPM) formats for simulating deep space communications. The resulting hybrid circuit has demonstrated 10 to 90 percent rise and fall times of less than 300 ps at peak currents exceeding 100 mA.

  19. Development of a 2-micron Pulsed Direct Detection IPDA Lidar for CO2 Measurement

    NASA Astrophysics Data System (ADS)

    Yu, J.; Petros, M.; Singh, U. N.

    2013-12-01

    NASA Langley is developing a 2-micron pulsed Integrated Path Differential Absorption (IPDA) lidar for atmospheric CO2 measurements. The high pulse energy, direct detection lidar operating at CO2 2-micron absorption band provides an alternate approach to measure CO2 concentrations with significant advantages. The objective of this development is to integrate an existing high energy double-pulsed 2-micron laser transmitter with a direct detection receiver and telescope to enable a first proof of principle demonstration of airborne direct detection CO2 measurements at 2-micron wavelength. It is expected to provide high-precision measurement capability by unambiguously eliminating contamination from aerosols and clouds that can bias the IPDA measurement. The system is scheduled to fly on NASA UC12 or B200 research aircrafts before the end of 2013. This paper will describe the design of the airborne 2-micron pulsed IPDA lidar system; the lidar operation parameters; the wavelength pair selection; laser transmitter energy, pulse rate, beam divergence, double pulse generation and accurate frequency control; detector characterization; telescope design; lidar structure design; and lidar signal to noise ratio estimation.

  20. Effects of shifts in the rate of repetitive stimulation on sustained attention

    NASA Technical Reports Server (NTRS)

    Krulewitz, J. E.; Warm, J. S.; Wohl, T. H.

    1975-01-01

    The effects of shifts in the rate of presentation of repetitive neutral events (background event rate) were studied in a visual vigilance task. Four groups of subjects experienced either a high (21 events/min) or a low (6 events/min) event rate for 20 min and then experienced either the same or the alternate event rate for an additional 40 min. The temporal occurrence of critical target signals was identical for all groups, irrespective of event rate. The density of critical signals was 12 signals/20 min. By the end of the session, shifts in event rate were associated with changes in performance which resembled contrast effects found in other experimental situations in which shift paradigms were used. Relative to constant event rate control conditions, a shift from a low to a high event rate depressed the probability of signal detections, while a shift in the opposite direction enhanced the probability of signal detections.

  1. 50 Mbps free space direct detection laser diode optical communication system with Q = 4 PPM signaling

    NASA Technical Reports Server (NTRS)

    Sun, Xiaoli; Davidson, Frederic; Field, Christopher

    1990-01-01

    A 50 Mbps direct detection optical communication system for use in an intersatellite link was constructed with an AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector. The system used a Q = 4 PPM format. The receiver consisted of a maximum likelihood PPM detector and a timing recovery subsystem. The PPM slot clock was recovered at the receiver by using a transition detector followed by a PLL. The PPM word clock was recovered by using a second PLL whose input was derived from the presence of back-to-back PPM pulses contained in the received random PPM pulse sequences. The system achieved a bit error rate of 0.000001 at less than 50 detected signal photons/information bit. The receiver was capable of acquiring and maintaining slot and word synchronization for received signal levels greater than 20 photons/information bit, at which the receiver bit error rate was about 0.01.

  2. TESAT laser communication terminal performance results on 5.6Gbit coherent inter satellite and satellite to ground links

    NASA Astrophysics Data System (ADS)

    Gregory, M.; Heine, F.; Kämpfner, H.; Meyer, R.; Fields, R.; Lunde, C.

    2017-11-01

    The increasing demand on high speed communication networks has stimulated the development of optical free space data transmission during the last years. TESAT has developed a laser communication terminal (LCT) that fulfills the need of a power efficient system whose capability has been successfully demonstrated at bidirectional space-to-space links and bidirectional space-to-ground links (SGLs) at a data rate of 5.625 GBit/s with a homodyne detection scheme and a BPSK modulation format. In comparison to a direct detection system, the homodyne detection scheme works as a bandpass filter. The transmission is immune to false light and even data transmission with the sun in the receiver field of view (FOV) is possible. Compared to common RF transmission which is implemented on spacecrafts for data transmission, optical transmission provides not only higher transmission rates (factor 10) but also shows excellent security features since the laser beams directivity making it immune to interception.

  3. Simulated Milky Way analogues: implications for dark matter direct searches

    NASA Astrophysics Data System (ADS)

    Bozorgnia, Nassim; Calore, Francesca; Schaller, Matthieu; Lovell, Mark; Bertone, Gianfranco; Frenk, Carlos S.; Crain, Robert A.; Navarro, Julio F.; Schaye, Joop; Theuns, Tom

    2016-05-01

    We study the implications of galaxy formation on dark matter direct detection using high resolution hydrodynamic simulations of Milky Way-like galaxies simulated within the EAGLE and APOSTLE projects. We identify Milky Way analogues that satisfy observational constraints on the Milky Way rotation curve and total stellar mass. We then extract the dark matter density and velocity distribution in the Solar neighbourhood for this set of Milky Way analogues, and use them to analyse the results of current direct detection experiments. For most Milky Way analogues, the event rates in direct detection experiments obtained from the best fit Maxwellian distribution (with peak speed of 223-289 km/s) are similar to those obtained directly from the simulations. As a consequence, the allowed regions and exclusion limits set by direct detection experiments in the dark matter mass and spin-independent cross section plane shift by a few GeV compared to the Standard Halo Model, at low dark matter masses. For each dark matter mass, the halo-to-halo variation of the local dark matter density results in an overall shift of the allowed regions and exclusion limits for the cross section. However, the compatibility of the possible hints for a dark matter signal from DAMA and CDMS-Si and null results from LUX and SuperCDMS is not improved.

  4. PSA-stratified detection rates for [68Ga]THP-PSMA, a novel probe for rapid kit-based 68Ga-labeling and PET imaging, in patients with biochemical recurrence after primary therapy for prostate cancer.

    PubMed

    Derlin, Thorsten; Schmuck, Sebastian; Juhl, Cathleen; Zörgiebel, Johanna; Schneefeld, Sophie M; Walte, Almut C A; Hueper, Katja; von Klot, Christoph A; Henkenberens, Christoph; Christiansen, Hans; Thackeray, James T; Ross, Tobias L; Bengel, Frank M

    2018-06-01

    [ 68 Ga]Tris(hydroxypyridinone)(THP)-PSMA is a novel radiopharmaceutical for one-step kit-based radiolabelling, based on direct chelation of 68 Ga 3+ at low concentration, room temperature and over a wide pH range, using direct elution from a 68 Ge/ 68 Ga-generator. We evaluated the clinical detection rates of [ 68 Ga]THP-PSMA PET/CT in patients with biochemically recurrent prostate cancer after prostatectomy. Consecutive patients (n=99) referred for evaluation of biochemical relapse of prostate cancer by [ 68 Ga]THP-PSMA PET/CT were analyzed retrospectively. Patients underwent a standard whole-body PET/CT (1 h p.i.), followed by delayed (3 h p.i.) imaging of the abdomen. PSA-stratified cohorts of positive PET/CT results, standardized uptake values (SUVs) and target-to-background ratios (TBRs) were analyzed, and compared between standard and delayed imaging. At least one lesion suggestive of recurrent or metastatic prostate cancer was identified on PET images in 52 patients (52.5%). Detection rates of [ 68 Ga]THP-PSMA PET/CT increased with increasing PSA level: 94.1% for a PSA value of ≥10 ng/mL, 77.3% for a PSA value of 2 to <10 ng/mL, 54.5% for a PSA value of 1 to <2 ng/mL, 14.3% for a PSA value of 0.5 to <1 ng/mL, 20.0% for a PSA value of >0.2 to <0.5, and 22.2% for a PSA value of 0.01 to 0.2 ng/mL. [ 68 Ga]THP-PSMA uptake (SUVs) in metastases decreased over time, whereas TBRs improved. Delayed imaging at 3 h p.i. exclusively identified pathologic findings in 2% of [ 68 Ga]THP-PSMA PET/CT scans. Detection rate was higher in patients with a Gleason score ≥8 (P=0.02) and in patients receiving androgen deprivation therapy (P=0.003). In this study, [ 68 Ga]THP-PSMA PET/CT showed suitable detection rates in patients with biochemical recurrence of prostate cancer and PSA levels ≥ 2 ng /mL. Detections rates were lower than in previous studies evaluating other PSMA ligands, though prospective direct radiotracer comparison studies are mandatory particularly in patients with low PSA levels to evaluate the relative performance of different PSMA ligands.

  5. Combining inferences from models of capture efficiency, detectability, and suitable habitat to classify landscapes for conservation of threatened bull trout

    USGS Publications Warehouse

    Peterson, J.; Dunham, J.B.

    2003-01-01

    Effective conservation efforts for at-risk species require knowledge of the locations of existing populations. Species presence can be estimated directly by conducting field-sampling surveys or alternatively by developing predictive models. Direct surveys can be expensive and inefficient, particularly for rare and difficult-to-sample species, and models of species presence may produce biased predictions. We present a Bayesian approach that combines sampling and model-based inferences for estimating species presence. The accuracy and cost-effectiveness of this approach were compared to those of sampling surveys and predictive models for estimating the presence of the threatened bull trout ( Salvelinus confluentus ) via simulation with existing models and empirical sampling data. Simulations indicated that a sampling-only approach would be the most effective and would result in the lowest presence and absence misclassification error rates for three thresholds of detection probability. When sampling effort was considered, however, the combined approach resulted in the lowest error rates per unit of sampling effort. Hence, lower probability-of-detection thresholds can be specified with the combined approach, resulting in lower misclassification error rates and improved cost-effectiveness.

  6. Screening for prostate cancer: estimating the magnitude of overdetection

    PubMed Central

    McGregor, M; Hanley, J A; Boivin, J F; McLean, R G

    1998-01-01

    BACKGROUND: No randomized controlled trial of prostate cancer screening has been reported and none is likely to be completed in the near future. In the absence of direct evidence, the decision to screen must therefore be based on estimates of benefits and risks. The main risk of screening is overdetection--the detection of cancer that, if left untreated, would not cause death. In this study the authors estimate the level of overdetection that might result from annual screening of men aged 50-70. METHODS: The annual rate of lethal screen-detectable cancer (detectable cancer that would prove fatal before age 85 if left untreated) was calculated from the observed prostate cancer mortality rate in Quebec; the annual rate of all cases of screen-detectable prostate cancer was calculated from 2 recent screening studies. RESULTS: The annual rate of lethal screen-detectable prostate cancer was estimated to be 1.3 per 1000 men. The annual rate of all cases of screen-detectable prostate cancer was estimated to be 8.0 per 1000 men. The estimated case-fatality rate among men up to 85 years of age was 16% (1.3/8.0) (sensitivity analysis 13% to 22%). INTERPRETATION: Of every 100 men with screen-detected prostate cancer, only 16 on average (13 to 22) could have their lives extended by surgery, since the prostate cancer would not cause death before age 85 in the remaining 84 (78 to 87). PMID:9861205

  7. Detection of oppositely directed reconnection jets in a solar wind current sheet

    NASA Astrophysics Data System (ADS)

    Davis, M. S.; Phan, T. D.; Gosling, J. T.; Skoug, R. M.

    2006-10-01

    We report the first two-spacecraft (Wind and ACE) detection of oppositely directed plasma jets within a bifurcated current sheet in the solar wind. The event occurred on January 3, 2003 and provides further direct evidence that such jets result from reconnection. The magnetic shear across the bifurcated current sheet at both Wind and ACE was ~150°, indicating that the magnetic shear must have been the same at the reconnection site located between the two spacecraft. These observations thus provide strong evidence for component merging with a guide field ~ 30% of the antiparallel field. The dimensionless reconnection rate based on the measured inflow was 0.03, implying fast reconnection.

  8. Detection of oppositely directed reconnection jets in a solar wind current sheet

    NASA Astrophysics Data System (ADS)

    Davis, M. S.; Phan, T. D.; Gosling, J. T.; Skoug, R. M.

    2006-12-01

    We report the first two-spacecraft (Wind and ACE) detection of oppositely directed plasma jets within a bifurcated current sheet in the solar wind. The event occurred on January 3, 2003 and provides further direct evidence that such jets result from reconnection. The magnetic shear across the bifurcated current sheet at both Wind and ACE was approximately 150 degrees, indicating that the magnetic shear must have been the same at the reconnection site located between the two spacecraft. These observations thus provide strong evidence for component merging with a guide field approximately 30% of the antiparallel field. The dimensionless reconnection rate based on the measured inflow was 0.03, implying fast reconnection.

  9. Measurement of soil creep by inclinometer

    Treesearch

    Robert R. Ziemer

    1977-01-01

    Abstract - Continued inclinometer measurements at borehole sites installed in 1964 in northern California suggest that previously reported rates of soil creep are excessively high. Upon analysis of 35 access casings located in forested and grassland sites, no consistent direction of soil movement could be detected. In addition, no significant rate of soil creep could...

  10. Local extinction and turnover rates at the edge and interior of species' ranges

    USGS Publications Warehouse

    Doherty, P.F.; Boulinier, T.; James., D.

    2003-01-01

    One hypothesis for the maintenance of the edge of a species' range suggests that more central (and abundant) populations are relatively stable and edge populations are less stable with increased local extinction and turnover rates. To date, estimates of such metrics are equivocal due to design and analysis flaws. Apparent increased estimates of extinction and turnover rates at the edge of range, versus the interior, could be a function of decreased detection probabilities alone, and not of a biological process. We estimated extinction and turnover rates for species at the interiors and edges of their ranges using an approach which incorporates potential heterogeneity in species detection probabilities. Extinction rates were higher at the edges (0.17 ?? 0.03 []) than in the interiors (0.04 ?? 0.01), as was turnover. Without taking the probability of detection into account these differences would be artificially magnified. Knowledge of extinction and turnover rates is essential in furthering our understanding of range dynamics, and in directing conservation efforts. This study further illustrates the practical application of methods proposed recently for estimating extinction rates and other community dynamic parameters.

  11. Local extinction and turnover rates at the edge and interior of species' ranges

    USGS Publications Warehouse

    Doherty, P.F.; Boulinier, T.; Nichols, J.D.

    2003-01-01

    One hypothesis for the maintenance of the edge of a species' range suggests that more central (and abundant) populations are relatively stable and edge populations are less stable with increased local extinction and turnover rates. To date, estimates of such metrics are equivocal due to design and analysis flaws. Apparent increased estimates of extinction and turnover rates at the edge of range, versus the interior, could be a function of decreased detection probabilities alone, and not of a biological process. We estimated extinction and turnover rates for species at the interiors and edges of their ranges using an approach which incorporates potential heterogeneity in species detection probabilities. Extinction rates were higher at the edges (0.17 ' 0.03 [SE]) than in the interiors (0.04 ' 0.01), as was turnover. Without taking the probability of detection into account these differences would be artificially magnified. Knowledge of extinction and turnover rates is essential in furthering our understanding of range dynamics, and in directing conservation efforts. This study further illustrates the practical application of methods proposed recently for estimating extinction rates and other community dynamic parameters.

  12. Nanopores and nucleic acids: prospects for ultrarapid sequencing

    NASA Technical Reports Server (NTRS)

    Deamer, D. W.; Akeson, M.

    2000-01-01

    DNA and RNA molecules can be detected as they are driven through a nanopore by an applied electric field at rates ranging from several hundred microseconds to a few milliseconds per molecule. The nanopore can rapidly discriminate between pyrimidine and purine segments along a single-stranded nucleic acid molecule. Nanopore detection and characterization of single molecules represents a new method for directly reading information encoded in linear polymers. If single-nucleotide resolution can be achieved, it is possible that nucleic acid sequences can be determined at rates exceeding a thousand bases per second.

  13. What are incident reports telling us? A comparative study at two Australian hospitals of medication errors identified at audit, detected by staff and reported to an incident system.

    PubMed

    Westbrook, Johanna I; Li, Ling; Lehnbom, Elin C; Baysari, Melissa T; Braithwaite, Jeffrey; Burke, Rosemary; Conn, Chris; Day, Richard O

    2015-02-01

    To (i) compare medication errors identified at audit and observation with medication incident reports; (ii) identify differences between two hospitals in incident report frequency and medication error rates; (iii) identify prescribing error detection rates by staff. Audit of 3291 patient records at two hospitals to identify prescribing errors and evidence of their detection by staff. Medication administration errors were identified from a direct observational study of 180 nurses administering 7451 medications. Severity of errors was classified. Those likely to lead to patient harm were categorized as 'clinically important'. Two major academic teaching hospitals in Sydney, Australia. Rates of medication errors identified from audit and from direct observation were compared with reported medication incident reports. A total of 12 567 prescribing errors were identified at audit. Of these 1.2/1000 errors (95% CI: 0.6-1.8) had incident reports. Clinically important prescribing errors (n = 539) were detected by staff at a rate of 218.9/1000 (95% CI: 184.0-253.8), but only 13.0/1000 (95% CI: 3.4-22.5) were reported. 78.1% (n = 421) of clinically important prescribing errors were not detected. A total of 2043 drug administrations (27.4%; 95% CI: 26.4-28.4%) contained ≥ 1 errors; none had an incident report. Hospital A had a higher frequency of incident reports than Hospital B, but a lower rate of errors at audit. Prescribing errors with the potential to cause harm frequently go undetected. Reported incidents do not reflect the profile of medication errors which occur in hospitals or the underlying rates. This demonstrates the inaccuracy of using incident frequency to compare patient risk or quality performance within or across hospitals. New approaches including data mining of electronic clinical information systems are required to support more effective medication error detection and mitigation. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care.

  14. Left atrial thrombus and dense spontaneous echocardiographic contrast in patients on continuous direct oral anticoagulant therapy undergoing catheter ablation of atrial fibrillation: Comparison of dabigatran, rivaroxaban, and apixaban.

    PubMed

    Wu, Michael; Gabriels, James; Khan, Mohammad; Shaban, Nada; D'Amato, Salvatore; Liu, Christopher F; Markowitz, Steven M; Ip, James E; Thomas, George; Singh, Parmanand; Lerman, Bruce; Patel, Apoor; Cheung, Jim W

    2018-04-01

    Left atrial thrombus (LAT) and dense spontaneous echocardiographic contrast (SEC) detected by transesophageal echocardiography (TEE) in patients on continuous direct oral anticoagulants (DOAC) therapy before catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL) have been described. We sought to compare rates of TEE-detected LAT and dense SEC among patients taking different DOACs. We evaluated 609 consecutive patients from 3 tertiary hospitals (median age 65 years; interquartile range 58-71 years; 436 (72%) men) who were on ≥4 weeks of continuous DOAC therapy (dabigatran, n = 166 [27%]; rivaroxaban, n = 257 [42%]; or apixaban, n = 186 [31%]) undergoing TEE before catheter ablation of AF/AFL. Demographic, clinical, and TEE data were collected for each patient. Despite ≥4 weeks of continuous DOAC therapy, 17 patients (2.8%) had LAT and 15 patients (2.5%) had dense SEC detected by TEE. The rates of LAT were 3.0%, 3.5%, and 1.6% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .482). The rates of dense SEC were 1.2%, 3.5%, and 2.2% for patients on dabigatran, rivaroxaban, and apixaban, respectively (P = .299). Congestive heart failure (odds ratio 4.4; 95% confidence interval 1.6-12; P = .003) and moderate/severe left atrial enlargement (odds ratio 3.1; 95% confidence interval 1.1-8.6; P = .026) were independent predictors of LAT. In this study, ∼3% of patients on continuous DOAC therapy had LAT detected before catheter ablation of AF/AFL. Specific DOAC therapy did not significantly affect the rates of LAT detection. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Model-independent comparison of annual modulation and total rate with direct detection experiments

    NASA Astrophysics Data System (ADS)

    Kahlhoefer, Felix; Reindl, Florian; Schäffner, Karoline; Schmidt-Hoberg, Kai; Wild, Sebastian

    2018-05-01

    The relative sensitivity of different direct detection experiments depends sensitively on the astrophysical distribution and particle physics nature of dark matter, prohibiting a model-independent comparison. The situation changes fundamentally if two experiments employ the same target material. We show that in this case one can compare measurements of an annual modulation and exclusion bounds on the total rate while making no assumptions on astrophysics and no (or only very general) assumptions on particle physics. In particular, we show that the dark matter interpretation of the DAMA/LIBRA signal can be conclusively tested with COSINUS, a future experiment employing the same target material. We find that if COSINUS excludes a dark matter scattering rate of about 0.01 kg‑1 days‑1 with an energy threshold of 1.8 keV and resolution of 0.2 keV, it will rule out all explanations of DAMA/LIBRA in terms of dark matter scattering off sodium and/or iodine.

  16. Development of a direct PCR assay to detect Taenia multiceps eggs isolated from dog feces.

    PubMed

    Wang, Ning; Wang, Yu; Ye, Qinghua; Yang, Yingdong; Wan, Jie; Guo, Cheng; Zhan, Jiafei; Gu, Xiaobin; Lai, Weimin; Xie, Yue; Peng, Xuerong; Yang, Guangyou

    2018-02-15

    Taenia multiceps is a tapeworm that leads to the death of livestock, resulting in major economic losses worldwide. The adult stage of this parasite invades the small intestine of dogs and other canids. In the present study, we developed a direct PCR assay to detect T. multiceps eggs isolated from dog feces to help curb further outbreaks. The genomic DNA was rapidly released using a lysis buffer and the PCR reaction was developed to amplify a 433-bp fragment of the T. multiceps mitochondrial gene encoding NADH dehydrogenase subunit 5 (nad5) from eggs isolated from dog feces. The procedure could be completed within 3 h, including flotation. The sensitivity of the assay was determined by detecting DNA from defined numbers of eggs, and the specificity was determined by detecting DNA from other intestinal tapeworm and roundworm species that commonly infect dogs. In addition, 14 taeniid-positive fecal samples determined by the flotation technique were collected and further evaluated by the regular PCR and our direct PCR. The results showed that the direct PCR developed herein was sensitive enough to detect the DNA from as few as 10 T. multiceps eggs and that no cross-reactions with other tapeworm and roundworm were observed, suggesting its high sensitivity and specificity for T. multiceps detection. Moreover, 14 taeniid-positive samples were screened by the regular PCR and direct PCR, with detection rates of 78.6% and 85.7%, respectively. In conclusion, the direct PCR assay developed in the present study has high sensitivity and specificity to identify T. multiceps eggs isolated from dog feces and therefore could represent an invaluable tool to identify T. multiceps outbreaks and would contribute to future clinical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Ultrafast electron microscopy integrated with a direct electron detection camera.

    PubMed

    Lee, Young Min; Kim, Young Jae; Kim, Ye-Jin; Kwon, Oh-Hoon

    2017-07-01

    In the past decade, we have witnessed the rapid growth of the field of ultrafast electron microscopy (UEM), which provides intuitive means to watch atomic and molecular motions of matter. Yet, because of the limited current of the pulsed electron beam resulting from space-charge effects, observations have been mainly made to periodic motions of the crystalline structure of hundreds of nanometers or higher by stroboscopic imaging at high repetition rates. Here, we develop an advanced UEM with robust capabilities for circumventing the present limitations by integrating a direct electron detection camera for the first time which allows for imaging at low repetition rates. This approach is expected to promote UEM to a more powerful platform to visualize molecular and collective motions and dissect fundamental physical, chemical, and materials phenomena in space and time.

  18. The fraternal WIMP miracle

    DOE PAGES

    Craig, Nathaniel; Katz, Andrey

    2015-10-27

    We identify and analyze thermal dark matter candidates in the fraternal twin Higgs model and its generalizations. The relic abundance of fraternal twin dark matter is set by twin weak interactions, with a scale tightly tied to the weak scale of the Standard Model by naturalness considerations. As such, the dark matter candidates benefit from a "fraternal WIMP miracle'', reproducing the observed dark matter abundance for dark matter masses between 50 and 150 GeV . However, the couplings dominantly responsible for dark matter annihilation do not lead to interactions with the visible sector. The direct detection rate is instead setmore » via fermionic Higgs portal interactions, which are likewise constrained by naturalness considerations but parametrically weaker than those leading to dark matter annihilation. Finally, the predicted direct detection cross section is close to current LUX bounds and presents an opportunity for the next generation of direct detection experiments.« less

  19. Comparison of automated processing of flocked swabs with manual processing of fiber swabs for detection of nasal carriage of Staphylococcus aureus.

    PubMed

    Jones, Gillian; Matthews, Roger; Cunningham, Richard; Jenks, Peter

    2011-07-01

    The sensitivity of automated culture of Staphylococcus aureus from flocked swabs versus that of manual culture of fiber swabs was prospectively compared using nasal swabs from 867 patients. Automated culture from flocked swabs significantly increased the detection rate, by 13.1% for direct culture and 10.2% for enrichment culture.

  20. Resolution enhancement of pump-probe microscope with an inverse-annular filter

    NASA Astrophysics Data System (ADS)

    Kobayashi, Takayoshi; Kawasumi, Koshi; Miyazaki, Jun; Nakata, Kazuaki

    2018-04-01

    Optical pump-probe microscopy can provide images by detecting changes in probe light intensity induced by stimulated emission, photoinduced absorbance change, or photothermal-induced refractive index change in either transmission or reflection mode. Photothermal microscopy, which is one type of optical pump-probe microscopy, has intrinsically super resolution capability due to the bilinear dependence of signal intensity of pump and probe. We introduce new techniques for further resolution enhancement and fast imaging in photothermal microscope. First, we introduce a new pupil filter, an inverse-annular pupil filter in a pump-probe photothermal microscope, which provides resolution enhancement in three dimensions. The resolutions are proved to be improved in lateral and axial directions by imaging experiment using 20-nm gold nanoparticles. The improvement in X (perpendicular to the common pump and probe polarization direction), Y (parallel to the polarization direction), and Z (axial direction) are by 15 ± 6, 8 ± 8, and 21 ± 2% from the resolution without a pupil filter. The resolution enhancement is even better than the calculation using vector field, which predicts the corresponding enhancement of 11, 8, and 6%. The discussion is made to explain the unexpected results. We also demonstrate the photothermal imaging of thick biological samples (cells from rabbit intestine and kidney) stained with hematoxylin and eosin dye with the inverse-annular filter. Second, a fast, high-sensitivity photothermal microscope is developed by implementing a spatially segmented balanced detection scheme into a laser scanning microscope using a Galvano mirror. We confirm a 4.9 times improvement in signal-to-noise ratio in the spatially segmented balanced detection compared with that of conventional detection. The system demonstrates simultaneous bi-modal photothermal and confocal fluorescence imaging of transgenic mouse brain tissue with a pixel dwell time of 20 µs. The fluorescence image visualizes neurons expressing yellow fluorescence proteins, while the photothermal signal detected endogenous chromophores in the mouse brain, allowing 3D visualization of the distribution of various features such as blood cells and fine structures most probably due to lipids. This imaging modality was constructed using compact and cost-effective laser diodes, and will thus be widely useful in the life and medical sciences. Third, we have made further resolution improvement of high-sensitivity laser scanning photothermal microscopy by applying non-linear detection. By this, the new method has super resolution with 61 and 42% enhancement from the diffraction limit values of the probe and pump wavelengths, respectively, by a second-order non-linear scheme and a high-frame rate in a laser scanning microscope. The maximum resolution is determined to be 160 nm in the second-order non-linear detection mode and 270 nm in the linear detection mode by the PT signal of GNPs. The pixel rate and frame rate for 300 × 300 pixel image are 50 µs and 4.5 s, respectively. The pixel and frame rate are shorter than the rates, those are 1 ms and 100 s, using the piezo-driven stage system.

  1. Digital filtering implementations for the detection of broad spectral features by direct analysis of passive Fourier transform infrared interferograms.

    PubMed

    Tarumi, Toshiyasu; Small, Gary W; Combs, Roger J; Kroutil, Robert T

    2004-04-01

    Finite impulse response (FIR) filters and finite impulse response matrix (FIRM) filters are evaluated for use in the detection of volatile organic compounds with wide spectral bands by direct analysis of interferogram data obtained from passive Fourier transform infrared (FT-IR) measurements. Short segments of filtered interferogram points are classified by support vector machines (SVMs) to implement the automated detection of heated plumes of the target analyte, ethanol. The interferograms employed in this study were acquired with a downward-looking passive FT-IR spectrometer mounted on a fixed-wing aircraft. Classifiers are trained with data collected on the ground and subsequently used for the airborne detection. The success of the automated detection depends on the effective removal of background contributions from the interferogram segments. Removing the background signature is complicated when the analyte spectral bands are broad because there is significant overlap between the interferogram representations of the analyte and background. Methods to implement the FIR and FIRM filters while excluding background contributions are explored in this work. When properly optimized, both filtering procedures provide satisfactory classification results for the airborne data. Missed detection rates of 8% or smaller for ethanol and false positive rates of at most 0.8% are realized. The optimization of filter design parameters, the starting interferogram point for filtering, and the length of the interferogram segments used in the pattern recognition is discussed.

  2. Optical communications and a comparison of optical technologies for a high data rate return link from Mars

    NASA Technical Reports Server (NTRS)

    Spence, Rodney L.

    1993-01-01

    The important principles of direct- and heterodyne-detection optical free-space communications are reviewed. Signal-to-noise-ratio (SNR) and bit-error-rate (BER) expressions are derived for both the direct-detection and heterodyne-detection optical receivers. For the heterodyne system, performance degradation resulting from received-signal and local oscillator-beam misalignment and laser phase noise is analyzed. Determination of interfering background power from local and extended background sources is discussed. The BER performance of direct- and heterodyne-detection optical links in the presence of Rayleigh-distributed random pointing and tracking errors is described. Finally, several optical systems employing Nd:YAG, GaAs, and CO2 laser sources are evaluated and compared to assess their feasibility in providing high-data-rate (10- to 1000-Mbps) Mars-to-Earth communications. It is shown that the root mean square (rms) pointing and tracking accuracy is a critical factor in defining the system transmitting laser-power requirements and telescope size and that, for a given rms error, there is an optimum telescope aperture size that minimizes the required power. The results of the analysis conducted indicate that, barring the achievement of extremely small rms pointing and tracking errors (less than 0.2 microrad), the two most promising types of optical systems are those that use an Nd:YAG laser (lambda = 1.064 microns) and high-order pulse position modulator (PPM) and direct detection, and those that use a CO2 laser (lambda = 10.6 microns) and phase shifting keying homodyne modulation and coherent detection. For example, for a PPM order of M = 64 and an rms pointing accuracy of 0.4 microrad, an Nd:YAG system can be used to implement a 100-Mbps Mars link with a 40-cm transmitting telescope, a 20-W laser, and a 10-m receiving photon bucket. Under the same conditions, a CO2 system would require 3-m transmitting and receiving telescopes and a 32-W laser to implement such a link. Other types of optical systems, such as a semiconductor laser systems, are impractical in the presence of large rms pointing errors because of the high power requirements of the 100-Mbps Mars link, even when optimal-size telescopes are used.

  3. Reconstructing WIMP properties through an interplay of signal measurements in direct detection, Fermi-LAT, and CTA searches for dark matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roszkowski, Leszek; Sessolo, Enrico Maria; Trojanowski, Sebastian

    2016-08-01

    We examine the projected ability to reconstruct the mass, scattering, and annihilation cross section of dark matter in the new generation of large underground detectors, XENON-1T, SuperCDMS, and DarkSide-G2, in combination with diffuse gamma radiation from expected 15 years of data from Fermi-LAT observation of 46 local spiral dwarf galaxies and projected CTA sensitivity to a signal from the Galactic Center. To this end we consider several benchmark points spanning a wide range of WIMP mass, different annihilation final states, and large enough event rates to warrant detection in one or more experiments. As previously shown, below some 100 GeVmore » only direct detection experiments will in principle be able to reconstruct WIMP mass well. This may, in case a signal at Fermi-LAT is also detected, additionally help restricting σ v and the allowed decay branching rates. In the intermediate range between some 100 GeV and up a few hundred GeV, direct and indirect detection experiments can be used in complementarity to ameliorate the respective determinations, which in individual experiments can at best be rather poor, thus making the WIMP reconstruction in this mass range very challenging. At large WIMP mass, ∼ 1 TeV, CTA will have the ability to reconstruct mass, annihilation cross section, and the allowed decay branching rates to very good precision for the τ{sup +}τ{sup -} or purely leptonic final state, good for the W {sup +} W {sup -} case, and rather poor for b b-bar . A substantial improvement can potentially be achieved by reducing the systematic uncertainties, increasing exposure, or by an additional measurement at Fermi-LAT that would help reconstruct the annihilation cross section and the allowed branching fractions to different final states.« less

  4. Methicillin-Resistant Staphylococcus aureus (MRSA) Detection: Comparison of Two Molecular Methods (IDI-MRSA PCR Assay and GenoType MRSA Direct PCR Assay) with Three Selective MRSA Agars (MRSA ID, MRSASelect, and CHROMagar MRSA) for Use with Infection-Control Swabs▿

    PubMed Central

    van Hal, S. J.; Stark, D.; Lockwood, B.; Marriott, D.; Harkness, J.

    2007-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an increasing problem. Rapid detection of MRSA-colonized patients has the potential to limit spread of the organism. We evaluated the sensitivities and specificities of MRSA detection by two molecular methods (IDI-MRSA PCR assay and GenoType MRSA Direct PCR assay) and three selective MRSA agars (MRSA ID, MRSASelect, and CHROMagar MRSA), using 205 (101 nasal, 52 groin, and 52 axillary samples) samples from consecutive known MRSA-infected and/or -colonized patients. All detection methods had higher MRSA detection rates for nasal swabs than for axillary and groin swabs. Detection of MRSA by IDI-MRSA was the most sensitive method, independent of the site (94% for nasal samples, 80% for nonnasal samples, and 90% overall). The sensitivities of the GenoType MRSA Direct assay and the MRSA ID, MRSASelect, and CHROMagar MRSA agars with nasal swabs were 70%, 72%, 68%, and 75%, respectively. All detection methods had high specificities (95 to 99%), independent of the swab site. Extended incubation for a further 24 h with selective MRSA agars increased the detection of MRSA, with a corresponding decline in specificity secondary to a significant increase in false-positive results. There was a noticeable difference in test performance of the GenoType MRSA Direct assay in detection of MRSA (28/38 samples [74%]) compared with detection of nonmultiresistant MRSA (17/31 samples [55%]) (susceptible to two or more non-β-lactam antibiotics). This was not observed with selective MRSA agar plates or IDI-MRSA. Although it is more expensive, in addition to rapid turnaround times of 2 to 4 h, IDI-MRSA offers greater detection of MRSA colonization, independent of the swab site, than do conventional selective agars and GenoType MRSA Direct. PMID:17537949

  5. Simulated Milky Way analogues: implications for dark matter direct searches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozorgnia, Nassim; Calore, Francesca; Lovell, Mark

    2016-05-01

    We study the implications of galaxy formation on dark matter direct detection using high resolution hydrodynamic simulations of Milky Way-like galaxies simulated within the EAGLE and APOSTLE projects. We identify Milky Way analogues that satisfy observational constraints on the Milky Way rotation curve and total stellar mass. We then extract the dark matter density and velocity distribution in the Solar neighbourhood for this set of Milky Way analogues, and use them to analyse the results of current direct detection experiments. For most Milky Way analogues, the event rates in direct detection experiments obtained from the best fit Maxwellian distribution (withmore » peak speed of 223–289 km/s) are similar to those obtained directly from the simulations. As a consequence, the allowed regions and exclusion limits set by direct detection experiments in the dark matter mass and spin-independent cross section plane shift by a few GeV compared to the Standard Halo Model, at low dark matter masses. For each dark matter mass, the halo-to-halo variation of the local dark matter density results in an overall shift of the allowed regions and exclusion limits for the cross section. However, the compatibility of the possible hints for a dark matter signal from DAMA and CDMS-Si and null results from LUX and SuperCDMS is not improved.« less

  6. Supernova Relic Neutrinos and the Supernova Rate Problem: Analysis of Uncertainties and Detectability of ONeMg and Failed Supernovae

    NASA Astrophysics Data System (ADS)

    Mathews, Grant J.; Hidaka, Jun; Kajino, Toshitaka; Suzuki, Jyutaro

    2014-08-01

    Direct measurements of the core collapse supernova rate (R SN) in the redshift range 0 <= z <= 1 appear to be about a factor of two smaller than the rate inferred from the measured cosmic massive star formation rate (SFR). This discrepancy would imply that about one-half of the massive stars that have been born in the local observed comoving volume did not explode as luminous supernovae. In this work, we explore the possibility that one could clarify the source of this "supernova rate problem" by detecting the energy spectrum of supernova relic neutrinos with a next generation 106 ton water Čerenkov detector like Hyper-Kamiokande. First, we re-examine the supernova rate problem. We make a conservative alternative compilation of the measured SFR data over the redshift range 0 <=z <= 7. We show that by only including published SFR data for which the dust obscuration has been directly determined, the ratio of the observed massive SFR to the observed supernova rate R SN has large uncertainties {\\sim }1.8^{+1.6}_{-0.6} and is statistically consistent with no supernova rate problem. If we further consider that a significant fraction of massive stars will end their lives as faint ONeMg SNe or as failed SNe leading to a black hole remnant, then the ratio reduces to {\\sim }1.1^{+1.0}_{-0.4} and the rate problem is essentially solved. We next examine the prospects for detecting this solution to the supernova rate problem. We first study the sources of uncertainty involved in the theoretical estimates of the neutrino detection rate and analyze whether the spectrum of relic neutrinos can be used to independently identify the existence of a supernova rate problem and its source. We consider an ensemble of published and unpublished core collapse supernova simulation models to estimate the uncertainties in the anticipated neutrino luminosities and temperatures. We illustrate how the spectrum of detector events might be used to establish the average neutrino temperature and constrain SN models. We also consider supernova ν-process nucleosynthesis to deduce constraints on the temperature of the various neutrino flavors. We study the effects of neutrino oscillations on the detected neutrino energy spectrum and also show that one might distinguish the equation of state (EoS) as well as the cause of the possible missing luminous supernovae from the detection of supernova relic neutrinos. We also analyze a possible enhanced contribution from failed supernovae leading to a black hole remnant as a solution to the supernova rate problem. We conclude that indeed it might be possible (though difficult) to measure the neutrino temperature, neutrino oscillations, and the EoS and confirm this source of missing luminous supernovae by the detection of the spectrum of relic neutrinos.

  7. Supernova relic neutrinos and the supernova rate problem: Analysis of uncertainties and detectability of ONeMg and failed supernovae

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathews, Grant J.; Hidaka, Jun; Kajino, Toshitaka

    2014-08-01

    Direct measurements of the core collapse supernova rate (R{sub SN}) in the redshift range 0 ≤ z ≤ 1 appear to be about a factor of two smaller than the rate inferred from the measured cosmic massive star formation rate (SFR). This discrepancy would imply that about one-half of the massive stars that have been born in the local observed comoving volume did not explode as luminous supernovae. In this work, we explore the possibility that one could clarify the source of this 'supernova rate problem' by detecting the energy spectrum of supernova relic neutrinos with a next generation 10{supmore » 6} ton water Čerenkov detector like Hyper-Kamiokande. First, we re-examine the supernova rate problem. We make a conservative alternative compilation of the measured SFR data over the redshift range 0 ≤z ≤ 7. We show that by only including published SFR data for which the dust obscuration has been directly determined, the ratio of the observed massive SFR to the observed supernova rate R{sub SN} has large uncertainties ∼1.8{sub −0.6}{sup +1.6} and is statistically consistent with no supernova rate problem. If we further consider that a significant fraction of massive stars will end their lives as faint ONeMg SNe or as failed SNe leading to a black hole remnant, then the ratio reduces to ∼1.1{sub −0.4}{sup +1.0} and the rate problem is essentially solved. We next examine the prospects for detecting this solution to the supernova rate problem. We first study the sources of uncertainty involved in the theoretical estimates of the neutrino detection rate and analyze whether the spectrum of relic neutrinos can be used to independently identify the existence of a supernova rate problem and its source. We consider an ensemble of published and unpublished core collapse supernova simulation models to estimate the uncertainties in the anticipated neutrino luminosities and temperatures. We illustrate how the spectrum of detector events might be used to establish the average neutrino temperature and constrain SN models. We also consider supernova ν-process nucleosynthesis to deduce constraints on the temperature of the various neutrino flavors. We study the effects of neutrino oscillations on the detected neutrino energy spectrum and also show that one might distinguish the equation of state (EoS) as well as the cause of the possible missing luminous supernovae from the detection of supernova relic neutrinos. We also analyze a possible enhanced contribution from failed supernovae leading to a black hole remnant as a solution to the supernova rate problem. We conclude that indeed it might be possible (though difficult) to measure the neutrino temperature, neutrino oscillations, and the EoS and confirm this source of missing luminous supernovae by the detection of the spectrum of relic neutrinos.« less

  8. Direct Observation of Parallel Folding Pathways Revealed Using a Symmetric Repeat Protein System

    PubMed Central

    Aksel, Tural; Barrick, Doug

    2014-01-01

    Although progress has been made to determine the native fold of a polypeptide from its primary structure, the diversity of pathways that connect the unfolded and folded states has not been adequately explored. Theoretical and computational studies predict that proteins fold through parallel pathways on funneled energy landscapes, although experimental detection of pathway diversity has been challenging. Here, we exploit the high translational symmetry and the direct length variation afforded by linear repeat proteins to directly detect folding through parallel pathways. By comparing folding rates of consensus ankyrin repeat proteins (CARPs), we find a clear increase in folding rates with increasing size and repeat number, although the size of the transition states (estimated from denaturant sensitivity) remains unchanged. The increase in folding rate with chain length, as opposed to a decrease expected from typical models for globular proteins, is a clear demonstration of parallel pathways. This conclusion is not dependent on extensive curve-fitting or structural perturbation of protein structure. By globally fitting a simple parallel-Ising pathway model, we have directly measured nucleation and propagation rates in protein folding, and have quantified the fluxes along each path, providing a detailed energy landscape for folding. This finding of parallel pathways differs from results from kinetic studies of repeat-proteins composed of sequence-variable repeats, where modest repeat-to-repeat energy variation coalesces folding into a single, dominant channel. Thus, for globular proteins, which have much higher variation in local structure and topology, parallel pathways are expected to be the exception rather than the rule. PMID:24988356

  9. [Clinical significance of drug resistance-associated mutations in treatment of hepatitis C with direct-acting antiviral agents].

    PubMed

    Li, Z; Chen, Z W; Ren, H; Hu, P

    2017-03-20

    Direct-acting antiviral agents (DAAs) achieve a high sustained virologic response rate in the treatment of chronic hepatitis C virus infection. However, drug resistance-associated mutations play an important role in treatment failure and have attracted more and more attention. This article elaborates on the clinical significance of drug resistance-associated mutations from the aspects of their definition, association with genotype, known drug resistance-associated mutations and their prevalence rates, the impact of drug resistance-associated mutations on treatment naive and treatment-experienced patients, and the role of clinical detection, in order to provide a reference for clinical regimens with DAAs and help to achieve higher sustained virologic response rates.

  10. Comparison of Automated Processing of Flocked Swabs with Manual Processing of Fiber Swabs for Detection of Nasal Carriage of Staphylococcus aureus▿‡

    PubMed Central

    Jones, Gillian; Matthews, Roger; Cunningham, Richard; Jenks, Peter

    2011-01-01

    The sensitivity of automated culture of Staphylococcus aureus from flocked swabs versus that of manual culture of fiber swabs was prospectively compared using nasal swabs from 867 patients. Automated culture from flocked swabs significantly increased the detection rate, by 13.1% for direct culture and 10.2% for enrichment culture. PMID:21525218

  11. Seasonal distribution of Legionella spp. and L. pneumophila in a river in Taiwan evaluated with culture-confirmed and direct DNA extraction methods

    NASA Astrophysics Data System (ADS)

    Tung, Min-Che; Chang, Tien-Yu; Hsu, Bing-Mu; Shen, Shu-Min; Huang, Jen-Te; Kao, Po-Min; Chiu, Yi-Chou; Fan, Cheng-Wei; Huang, Yu-Li

    2013-07-01

    In this study, we evaluated the presence and amount of Legionella in along a river in Taiwan, and the relations between seasonal distribution of Legionella spp. and geographic characteristics in the watershed were also evaluated. Water samples were pre-treated and analyzed with culture-confirmed and direct DNA extraction methods. For culture-confirmed method, water samples were cultivated through a series of selective media, and candidate colonies were confirmed by PCR. For direct DNA extraction method, direct DNA extraction was performed from pre-treated water samples. The DNA extracts were analyzed with PCR and DNA sequence analysis for species determination, quantitative PCR (qPCR) was performed to quantify Legionella concentration in the water sample. In all, 150 water samples were included in this study, with 73 (48.6%) water samples detected with Legionella spp., and 17 with L. pneumophila. Over 80% Legionella spp. detections were through direct DNA extraction method, but more than 80% L. pneumophila detections were through culture-confirmed method. While detection of Legionella spp. was done with two methods, positive results were found through only one method. Legionella spp. was detected in all seasons with detection rate ranging between 34.3-58.8% and seasonal average concentration from 1.9 × 102 to 7.1 × 103 CFU/L. Most of the L. pneumophila detections were from samples collected in fall (38.2%) and summer (6.0%), which also coincided with increased cases of Legionellosis reported through Center of Disease Control in Taiwan. The high prevalence and concentration of Legionella spp. and L. pneumophila in the surface waters should be further evaluated for potential health risks.

  12. Exploiting semantics for sensor re-calibration in event detection systems

    NASA Astrophysics Data System (ADS)

    Vaisenberg, Ronen; Ji, Shengyue; Hore, Bijit; Mehrotra, Sharad; Venkatasubramanian, Nalini

    2008-01-01

    Event detection from a video stream is becoming an important and challenging task in surveillance and sentient systems. While computer vision has been extensively studied to solve different kinds of detection problems over time, it is still a hard problem and even in a controlled environment only simple events can be detected with a high degree of accuracy. Instead of struggling to improve event detection using image processing only, we bring in semantics to direct traditional image processing. Semantics are the underlying facts that hide beneath video frames, which can not be "seen" directly by image processing. In this work we demonstrate that time sequence semantics can be exploited to guide unsupervised re-calibration of the event detection system. We present an instantiation of our ideas by using an appliance as an example--Coffee Pot level detection based on video data--to show that semantics can guide the re-calibration of the detection model. This work exploits time sequence semantics to detect when re-calibration is required to automatically relearn a new detection model for the newly evolved system state and to resume monitoring with a higher rate of accuracy.

  13. Subliminal smells can guide social preferences.

    PubMed

    Li, Wen; Moallem, Isabel; Paller, Ken A; Gottfried, Jay A

    2007-12-01

    It is widely accepted that unconscious processes can modulate judgments and behavior, but do such influences affect one's daily interactions with other people? Given that olfactory information has relatively direct access to cortical and subcortical emotional circuits, we tested whether the affective content of subliminal odors alters social preferences. Participants rated the likeability of neutral faces after smelling pleasant, neutral, or unpleasant odors delivered below detection thresholds. Odor affect significantly shifted likeability ratings only for those participants lacking conscious awareness of the smells, as verified by chance-level trial-by-trial performance on an odor-detection task. Across participants, the magnitude of this priming effect decreased as sensitivity for odor detection increased. In contrast, heart rate responses tracked odor valence independently of odor awareness. These results indicate that social preferences are subject to influences from odors that escape awareness, whereas the availability of conscious odor information may disrupt such effects.

  14. Repeated Induction of Inattentional Blindness in a Simulated Aviation Environment

    NASA Technical Reports Server (NTRS)

    Kennedy, Kellie D.; Stephens, Chad L.; Williams, Ralph A.; Schutte, Paul C.

    2017-01-01

    The study reported herein is a subset of a larger investigation on the role of automation in the context of the flight deck and used a fixed-based, human-in-the-loop simulator. This paper explored the relationship between automation and inattentional blindness (IB) occurrences in a repeated induction paradigm using two types of runway incursions. The critical stimuli for both runway incursions were directly relevant to primary task performance. Sixty non-pilot participants performed the final five minutes of a landing scenario twice in one of three automation conditions: full automation (FA), partial automation (PA), and no automation (NA). The first induction resulted in a 70 percent (42 of 60) detection failure rate with those in the PA condition significantly more likely to detect the incursion compared to the FA condition or the NA condition. The second induction yielded a 50 percent detection failure rate. Although detection improved (detection failure rates declined) in all conditions, those in the FA condition demonstrated the greatest improvement with doubled detection rates. The detection behavior in the first trial did not preclude a failed detection in the second induction. Group membership (IB vs. Detection) in the FA condition showed a greater improvement than those in the NA condition and rated the Mental Demand and Effort subscales of the NASA-TLX (NASA Task Load Index) significantly higher for Time 2 compared Time 1. Participants in the FA condition used the experience of IB exposure to improve task performance whereas those in the NA condition did not, indicating the availability and reallocation of attentional resources in the FA condition. These findings support the role of engagement in operational attention detriment and the consideration of attentional failure causation to determine appropriate mitigation strategies.

  15. Comparison of the Simplexa HSV1 & 2 Direct kit and laboratory-developed real-time PCR assays for herpes simplex virus detection.

    PubMed

    Kuypers, Jane; Boughton, Gregory; Chung, Jina; Hussey, Lindsay; Huang, Meei-Li; Cook, Linda; Jerome, Keith R

    2015-01-01

    Rapid detection and differentiation of herpes simplex viruses (HSV) is important for patient management and treatment, especially in HSV meningoencephalitis. Results of Simplexa HSV1 & 2 Direct kit (Focus Diagnostics), an FDA-cleared sample-to-result method providing results in ∼ 75 min, were compared to those of laboratory-developed real-time PCR assays (LDT) for detection of HSV1 and HSV2. Samples tested included 168 cerebral spinal fluid (CSF) collected prospectively and 150 tested retrospectively: 81 from clinical testing and 69 from subjects in a neonatal herpes study; and 53 plasma and sera. Each sample was tested by both methods on the same day. Three of 318 CSF had invalid Simplexa Direct results and negative LDT results. Three neonatal samples with low HSV viral loads by LDT could not be typed; two were HSV2 positive and one was negative by Simplexa Direct. Of 312 CSF with valid, type-specific results, HSV1 was detected in 16 by LDT and in 17 by Simplexa Direct; HSV2 was detected in 48 by LDT and in 49 by Simplexa Direct. Concordance rates were 98.4% (κ 0.84) and 97.1% (κ 0.89) for HSV1 and HSV2, respectively. Positive percent agreements were 87.5% for HSV1 and 91.7% for HSV2. Two and four CSF were positive only by LDT and three and five were positive only by Simplexa Direct for HSV1 and HSV2, respectively. Simplexa HSV1 & 2 assay performed well compared to an established LDT. The faster turn-around-time compared to LDT will allow for more rapid antiviral treatment and better patient management. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. [Analysis of EML4-ALK gene fusion mutation in patients 
with non-small cell lung cancer].

    PubMed

    Wang, Xuzhou; Chen, Weisheng; Yu, Yinghao

    2015-02-01

    Non-small cell lung cancer (NSCLC) is the main type of lung cancer, and the related locus mutation detection research has become a hot direction of molecular targeted therapy, studying on gene mutation status of echinodem microtubule associated protein like 4-Anaplastic lymphoma kinase (EML4-ALK) and epidermal growth factor receptor (EGFR), detecting the sensitivity of EML4-ALK gene fusion and gene mutation of EGFR. EML4-ALK gene fusion in 85 cases of paraffin embedded tumor tissue and adjacent lung tissue was detected with the application of immunohistochemistry (IHC), Scorpions amplification refractory mutation system (Scorpions ARMS) fluorescence quantitative PCR and fluorescence in situ hybridization (FISH) technology, and EGFR gene in 18, 19, 20 and 21 exon mutation status was detected with the application of ARMS method. In 115 cases of NSCLC, IHC showed 32 cases with ALK (D5F3) expression, the expression rate was 27.8%; ARMS showed 27 cases with EML4-ALK fusion gene mutation, the mutation detection rate was 23.5%; 53 cases were detected with EGFR mutation, the mutation rate was 46%. While FISH showed 23 cases with EML4-ALK fusion gene mutation, the detection rate was 20%, slightly lower than the ARMS detection results, suggesting that ARMS more sensitive. The application of IHC, ARMS fluorescence quantitative PCR and FISH technology can make a rapid and accurate evaluation of EML4-ALK gene fusion.

  17. Monthly modulation in dark matter direct-detection experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Britto, Vivian; Meyers, Joel, E-mail: vivian.britto@mail.utoronto.ca, E-mail: jmeyers@cita.utoronto.ca

    2015-11-01

    The signals in dark matter direct-detection experiments should exhibit modulation signatures due to the Earth's motion with respect to the Galactic dark matter halo. The annual and daily modulations, due to the Earth's revolution about the Sun and rotation about its own axis, have been explored previously. Monthly modulation is another such feature present in direct detection signals, and provides a nearly model-independent method of distinguishing dark matter signal events from background. We study here monthly modulations in detail for both WIMP and WISP dark matter searches, examining both the effect of the motion of the Earth about the Earth-Moonmore » barycenter and the gravitational focusing due to the Moon. For WIMP searches, we calculate the monthly modulation of the count rate and show the effects are too small to be observed in the foreseeable future. For WISP dark matter experiments, we show that the photons generated by WISP to photon conversion have frequencies which undergo a monthly modulating shift which is detectable with current technology and which cannot in general be neglected in high resolution WISP searches.« less

  18. Ultrafast web inspection with hybrid dispersion laser scanner.

    PubMed

    Chen, Hongwei; Wang, Chao; Yazaki, Akio; Kim, Chanju; Goda, Keisuke; Jalali, Bahram

    2013-06-10

    We report an ultrafast web inspector that operates at a 1000 times higher scan rate than conventional methods. This system is based on a hybrid dispersion laser scanner that performs line scans at nearly 100 MHz. Specifically, we demonstrate web inspection with detectable resolution of 48.6 μm/pixel (scan direction) × 23 μm (web flow direction) within a width of view of 6 mm at a record high scan rate of 90.9 MHz. We demonstrate the identification and evaluation of particles on silicon wafers. This method holds great promise for speeding up quality control and hence reducing manufacturing costs.

  19. A dual-process account of auditory change detection.

    PubMed

    McAnally, Ken I; Martin, Russell L; Eramudugolla, Ranmalee; Stuart, Geoffrey W; Irvine, Dexter R F; Mattingley, Jason B

    2010-08-01

    Listeners can be "deaf" to a substantial change in a scene comprising multiple auditory objects unless their attention has been directed to the changed object. It is unclear whether auditory change detection relies on identification of the objects in pre- and post-change scenes. We compared the rates at which listeners correctly identify changed objects with those predicted by change-detection models based on signal detection theory (SDT) and high-threshold theory (HTT). Detected changes were not identified as accurately as predicted by models based on either theory, suggesting that some changes are detected by a process that does not support change identification. Undetected changes were identified as accurately as predicted by the HTT model but much less accurately than predicted by the SDT models. The process underlying change detection was investigated further by determining receiver-operating characteristics (ROCs). ROCs did not conform to those predicted by either a SDT or a HTT model but were well modeled by a dual-process that incorporated HTT and SDT components. The dual-process model also accurately predicted the rates at which detected and undetected changes were correctly identified.

  20. 6.4 Tb/s (32 × 200 Gb/s) WDM direct-detection transmission with twin-SSB modulation and Kramers-Kronig receiver

    NASA Astrophysics Data System (ADS)

    Zhu, Yixiao; Jiang, Mingxuan; Ruan, Xiaoke; Chen, Zeyu; Li, Chenjia; Zhang, Fan

    2018-05-01

    We experimentally demonstrate 6.4 Tb/s wavelength division multiplexed (WDM) direct-detection transmission based on Nyquist twin-SSB modulation over 25 km SSMF with bit error rates (BERs) below the 20% hard-decision forward error correction (HD-FEC) threshold of 1.5 × 10-2. The two sidebands of each channel are separately detected using Kramers-Kronig receiver without MIMO equalization. We also carry out numerical simulations to evaluate the system robustness against I/Q amplitude imbalance, I/Q phase deviation and the extinction ratio of modulator, respectively. Furthermore, we show in simulation that the requirement of steep edge optical filter can be relaxed if multi-input-multi-output (MIMO) equalization between the two sidebands is used.

  1. Capacity of a direct detection optical communication channel

    NASA Technical Reports Server (NTRS)

    Tan, H. H.

    1980-01-01

    The capacity of a free space optical channel using a direct detection receiver is derived under both peak and average signal power constraints and without a signal bandwidth constraint. The addition of instantaneous noiseless feedback from the receiver to the transmitter does not increase the channel capacity. In the absence of received background noise, an optimally coded PPM system is shown to achieve capacity in the limit as signal bandwidth approaches infinity. In the case of large peak to average signal power ratios, an interleaved coding scheme with PPM modulation is shown to have a computational cutoff rate far greater than ordinary coding schemes.

  2. Fluorescent in situ hybridization: an effective and less costly technique for genetic evaluation of products of conception in pregnancy losses.

    PubMed

    Fejgin, Moshe D; Pomeranz, Meir; Liberman, Meytal; Fishman, Ami; Amiel, Aliza

    2005-09-01

    In this study, we applied the fluorescent in situ hybridization (FISH) technique and compared the common numerical abnormalities with chromosomes 13, 16, 18, 21, X, and Y in spontaneous to artificial abortion. This would cover about 75% of the common aneuploidy in spontaneous abortion. Placentas were taken from 59 patients with a first trimester spontaneous abortion and 61 patients who underwent an elective first trimester pregnancy termination. The range of growth was from 5 to 12 gestational weeks. Placentas were processed according to direct chorionic villi preparation. Direct dual color FISH was performed according to Vysis protocol with the probes for the following chromosomes: 13, 16, 18, 21, X, and Y. The aneuploidy rate in spontaneous abortion was 55.9% and in artificial abortion 8.2%. There was a significant difference between the two groups in the aneuploidy rate (P = 6 x 10(-9)). FISH is a rapid, efficient, and relatively inexpensive tool in detecting aneuploidy in placentas from cases of spontaneous abortions. Our rate of detected aneuploidy is compatible with other reports in which conventional cytogenetics was utilized.

  3. Experimental demonstration of 608Gbit/s short reach transmission employing half-cycle 16QAM Nyquist-SCM signal and direct detection with 25Gbps EML.

    PubMed

    Zhong, Kangping; Zhou, Xian; Wang, Yiguang; Wang, Liang; Yuan, Jinhui; Yu, Changyuan; Lau, Alan Pak Tao; Lu, Chao

    2016-10-31

    In this paper, we experimentally demonstrated an IM/DD short reach transmission system with a total capacity of 608Gbit/s (net capacity of 565.4Gbit/s exclude 7% FEC overhead) employing half-cycle 16QAM Nyquist-SCM signal and 25Gbps EML at O band. Direct detection-faster than Nyquist (DD-FTN) technique was employed to compensate channel impairments. Number of taps of DD-LMS and tap coefficient of post filter in DD-FTN were experimentally studied for different baud rates. Single-lane 152Gbit/s transmission over 10km of SSMF was experimentally demonstrated. Employing a 4-lanes LAN-WDM architecture, a total capacity of 608Gbit/s transmission over 2km was successfully achieved with a receiver sensitivity lower than -4dBm. To the best of authors' knowledge, this is the highest reported baud rate of half-cycle 16QAM Nyquist-SCM signal and the highest bit rate employing IM/DD and 25Gbps EML in a four lanes LAN-WDM architecture for short reach systems in the O band.

  4. Methodology to assess water presence on speleothems during periods of low precipitation, with implications for recharge sources - Kartchner Caverns, Arizona

    USGS Publications Warehouse

    Blasch, Kyle W.

    2011-01-01

    Beginning in January 2005, recharge processes and the presence of water on speleothems were monitored in Kartchner Caverns during a 44-month period when annual rainfall rates were 6 to 18 percent below the long-term mean. Electrical-resistance sensors designed to detect the presence of water were used to identify ephemeral streamflow in the channels overlying the cave as well as the movement of water within the cave system. Direct infiltration of precipitation through overhead rocks provided consistent inflow to the cave, but precipitation rates and subsequent infiltration rates were reduced during the comparatively dry years. Ephemeral stream-channel recharge through autogenic and allogenic processes, the predominant recharge mechanism during wetter periods, was limited to two low-volume events. From visual observations, it appeared that recharge from channel infiltration was equal to or less than recharge from overhead infiltration. Electrical-resistance sensors were able to detect thin films of water on speleothems, including stalactites, ribbons, and stalagmites. These films of water were directly attributed to overhead infiltration of precipitation. Periods of low precipitation resulted in decreased speleothem wetness.

  5. Cost-benefit analysis: newborn screening for inborn errors of metabolism in Lebanon.

    PubMed

    Khneisser, I; Adib, S; Assaad, S; Megarbane, A; Karam, P

    2015-12-01

    Few countries in the Middle East-North Africa region have adopted national newborn screening for inborn errors of metabolism by tandem mass spectrometry (MS/MS). We aimed to evaluate the cost-benefit of newborn screening for such disorders in Lebanon, as a model for other developing countries in the region. Average costs of expected care for inborn errors of metabolism cases as a group, between ages 0 and 18, early and late diagnosed, were calculated from 2007 to 2013. The monetary value of early detection using MS/MS was compared with that of clinical "late detection", including cost of diagnosis and hospitalizations. During this period, 126000 newborns were screened. Incidence of detected cases was 1/1482, which can be explained by high consanguinity rates in Lebanon. A reduction by half of direct cost of care, reaching on average 31,631 USD per detected case was shown. This difference more than covers the expense of starting a newborn screening programme. Although this model does not take into consideration the indirect benefits of the better quality of life of those screened early, it can be argued that direct and indirect costs saved through early detection of these disorders are important enough to justify universal publicly-funded screening, especially in developing countries with high consanguinity rates, as shown through this data from Lebanon. © The Author(s) 2015.

  6. Automated Detection of Atrial Fibrillation Based on Time-Frequency Analysis of Seismocardiograms.

    PubMed

    Hurnanen, Tero; Lehtonen, Eero; Tadi, Mojtaba Jafari; Kuusela, Tom; Kiviniemi, Tuomas; Saraste, Antti; Vasankari, Tuija; Airaksinen, Juhani; Koivisto, Tero; Pankaala, Mikko

    2017-09-01

    In this paper, a novel method to detect atrial fibrillation (AFib) from a seismocardiogram (SCG) is presented. The proposed method is based on linear classification of the spectral entropy and a heart rate variability index computed from the SCG. The performance of the developed algorithm is demonstrated on data gathered from 13 patients in clinical setting. After motion artifact removal, in total 119 min of AFib data and 126 min of sinus rhythm data were considered for automated AFib detection. No other arrhythmias were considered in this study. The proposed algorithm requires no direct heartbeat peak detection from the SCG data, which makes it tolerant against interpersonal variations in the SCG morphology, and noise. Furthermore, the proposed method relies solely on the SCG and needs no complementary electrocardiography to be functional. For the considered data, the detection method performs well even on relatively low quality SCG signals. Using a majority voting scheme that takes five randomly selected segments from a signal and classifies these segments using the proposed algorithm, we obtained an average true positive rate of [Formula: see text] and an average true negative rate of [Formula: see text] for detecting AFib in leave-one-out cross-validation. This paper facilitates adoption of microelectromechanical sensor based heart monitoring devices for arrhythmia detection.

  7. Clearance of chlamydial elementary bodies from the conjunctival sac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, H.R.; Velez, V.L.

    1987-07-01

    The rate of disappearance of inactivated Chlamydia trachomatis elementary body (EB) preparations from the conjunctival sac was studied in monkeys. Direct fluorescent antibody (DFA) cytology showed that the majority of EB had been cleared from the eye within 24 hr of the inoculation of 1 X 10(6) inactivated EB, although small numbers of EB could be detected for up to 144 hr. The rate of clearance in normal and ocular immune animals did not differ, and formalin-killed and UV-inactivated EBs disappeared at a comparable rate. These studies suggest that chlamydial EB are cleared relatively quickly from the eye and supportmore » the notion that EBs detected by DFA cytology indicate the presence of current infection.« less

  8. Astrophysical uncertainties on the local dark matter distribution and direct detection experiments

    NASA Astrophysics Data System (ADS)

    Green, Anne M.

    2017-08-01

    The differential event rate in weakly interacting massive particle (WIMP) direct detection experiments depends on the local dark matter density and velocity distribution. Accurate modelling of the local dark matter distribution is therefore required to obtain reliable constraints on the WIMP particle physics properties. Data analyses typically use a simple standard halo model which might not be a good approximation to the real Milky Way (MW) halo. We review observational determinations of the local dark matter density, circular speed and escape speed and also studies of the local dark matter distribution in simulated MW-like galaxies. We discuss the effects of the uncertainties in these quantities on the energy spectrum and its time and direction dependence. Finally, we conclude with an overview of various methods for handling these astrophysical uncertainties.

  9. Direct connections assist neurons to detect correlation in small amplitude noises

    PubMed Central

    Bolhasani, E.; Azizi, Y.; Valizadeh, A.

    2013-01-01

    We address a question on the effect of common stochastic inputs on the correlation of the spike trains of two neurons when they are coupled through direct connections. We show that the change in the correlation of small amplitude stochastic inputs can be better detected when the neurons are connected by direct excitatory couplings. Depending on whether intrinsic firing rate of the neurons is identical or slightly different, symmetric or asymmetric connections can increase the sensitivity of the system to the input correlation by changing the mean slope of the correlation transfer function over a given range of input correlation. In either case, there is also an optimum value for synaptic strength which maximizes the sensitivity of the system to the changes in input correlation. PMID:23966940

  10. Doppler endoscopic probe as a guide to risk stratification and definitive hemostasis of peptic ulcer bleeding.

    PubMed

    Jensen, Dennis M; Ohning, Gordon V; Kovacs, Thomas O G; Ghassemi, Kevin A; Jutabha, Rome; Dulai, Gareth S; Machicado, Gustavo A

    2016-01-01

    For more than 4 decades endoscopists have relied on ulcer stigmata for risk stratification and as a guide to hemostasis. None used arterial blood flow underneath stigmata to predict outcomes. For patients with severe peptic ulcer bleeding (PUB), we used a Doppler endoscopic probe (DEP) for (1) detection of blood flow underlying stigmata of recent hemorrhage (SRH), (2) quantitating rates of residual arterial blood flow under SRH after visually directed standard endoscopic treatment, and (3) comparing risks of rebleeding and actual 30-day rebleed rates for spurting arterial bleeding (Forrest [F] IA) and oozing bleeding (F IB). Prospective cohort study of 163 consecutive patients with severe PUB and different SRH. All blood flow detected by the DEP was arterial. Detection rates were 87.4% in major SRH-spurting arterial bleeding (F IA), non-bleeding visible vessel (F IIA), clot (F IIB)-and were significantly lower at 42.3% (P < .0001) for an intermediate group of oozing bleeding (F IB) or flat spot (F IIC). For spurting bleeding (F IA) versus oozing (F IB), baseline DEP arterial flow was 100% versus 46.7%, residual blood flow detected after endoscopic hemostasis was 35.7% versus 0%, and 30-day rebleed rates were 28.6% versus 0% (all P < .05). (1) For major SRH versus oozing or spot, the arterial blood flow detection rate by the DEP was significantly higher, indicating a higher rebleed risk. (2) Before and after endoscopic treatment, spurting (F IA) PUB had significantly higher rates of blood flow detection than oozing (F IB) PUB and a significantly higher 30-day rebleed rate. (3) The DEP is recommended as a new endoscopic guide with SRH to improve risk stratification and potentially definitive hemostasis for PUB. Published by Elsevier Inc.

  11. Doppler Endoscopic Probe as a Guide to Risk Stratification and Definitive Hemostasis of Peptic Ulcer Bleeding

    PubMed Central

    Jensen, Dennis M.; Ohning, Gordon V.; Kovacs, Thomas OG; Ghassemi, Kevin A.; Jutabha, Rome; Dulai, Gareth S.; Machicado, Gustavo A.

    2015-01-01

    Background and Aims For more than 4 decades endoscopists have relied on ulcer stigmata for risk stratification and as a guide to hemostasis. None used arterial blood flow underneath stigmata to predict outcomes. For patients with severe peptic ulcer bleeding (PUBs), we used Doppler endoscopic probe (DEP) for: 1. detection of blood flow underlying stigmata of recent hemorrhage (SRH), 2. quantitating rates of residual arterial blood flow under SRH after visually directed standard endoscopic treatment, and 3. comparing risks of rebleeding and actual 30 day rebleed rates for spurting arterial bleeding (Forrest – FIA) and oozing bleeding (FIB). Methods Prospective cohort study of 163 consecutive patients with severe PUBs and different SRH. Results All blood flow detected by DEP was arterial. Detection rates were 87.4% in major SRH - spurting arterial bleeding (FIA), non bleeding visible vessel (FIIA), clot (FIIB) - and significantly lower at 42.3% (p<0.0001) for intermediate group of oozing bleeding (FIB) or flat spot (FIIC). For spurting bleeding (FIA) vs. oozing (FIB), baseline DEP arterial flow was 100% vs. 46.7%; residual blood flow detected after endoscopic hemostasis was 35.7% vs. 0%; and 30 day rebleed rates were 28.6% vs. 0% (all p<0.05). Conclusions 1. For major SRH vs. oozing or spot, the arterial blood flow detection rates by DEP was significantly higher, indicating a higher rebleed risk. 2. Before and after endoscopic treatment, spurting FIA PUB’s had significantly higher rates of blood flow detection than oozing FIB PUB’s and a significantly higher 30 rebleed rate. 3. DEP is recommended as a new endoscopic guide with SRH to improve risk stratification and potentially definitive hemostasis for PUBs. PMID:26318834

  12. A history of radiation detection instrumentation.

    PubMed

    Frame, Paul W

    2004-08-01

    A review is presented of the history of radiation detection instrumentation. Specific radiation detection systems that are discussed include the human senses, photography, calorimetry, color dosimetry, ion chambers, electrometers, electroscopes, proportional counters, Geiger Mueller counters, scalers and rate meters, barium platinocyanide, scintillation counters, semiconductor detectors, radiophotoluminescent dosimeters, thermoluminescent dosimeters, optically stimulated luminescent dosimeters, direct ion storage, electrets, cloud chambers, bubble chambers, and bubble dosimeters. Given the broad scope of this review, the coverage is limited to a few key events in the development of a given detection system and some relevant operating principles. The occasional anecdote is included for interest.

  13. A history of radiation detection instrumentation.

    PubMed

    Frame, Paul W

    2005-06-01

    A review is presented of the history of radiation detection instrumentation. Specific radiation detection systems that are discussed include the human senses, photography, calorimetry, color dosimetry, ion chambers, electrometers, electroscopes, proportional counters, Geiger Mueller counters, scalers and rate meters, barium platinocyanide, scintillation counters, semiconductor detectors, radiophotoluminescent dosimeters, thermoluminescent dosimeters, optically stimulated luminescent dosimeters, direct ion storage, electrets, cloud chambers, bubble chambers, and bubble dosimeters. Given the broad scope of this review, the coverage is limited to a few key events in the development of a given detection system and some relevant operating principles. The occasional anecdote is included for interest.

  14. A statistical model of false negative and false positive detection of phase singularities.

    PubMed

    Jacquemet, Vincent

    2017-10-01

    The complexity of cardiac fibrillation dynamics can be assessed by analyzing the distribution of phase singularities (PSs) observed using mapping systems. Interelectrode distance, however, limits the accuracy of PS detection. To investigate in a theoretical framework the PS false negative and false positive rates in relation to the characteristics of the mapping system and fibrillation dynamics, we propose a statistical model of phase maps with controllable number and locations of PSs. In this model, phase maps are generated from randomly distributed PSs with physiologically-plausible directions of rotation. Noise and distortion of the phase are added. PSs are detected using topological charge contour integrals on regular grids of varying resolutions. Over 100 × 10 6 realizations of the random field process are used to estimate average false negative and false positive rates using a Monte-Carlo approach. The false detection rates are shown to depend on the average distance between neighboring PSs expressed in units of interelectrode distance, following approximately a power law with exponents in the range of 1.14 to 2 for false negatives and around 2.8 for false positives. In the presence of noise or distortion of phase, false detection rates at high resolution tend to a non-zero noise-dependent lower bound. This model provides an easy-to-implement tool for benchmarking PS detection algorithms over a broad range of configurations with multiple PSs.

  15. Radar mechanocardiography: a novel analysis of the mechanical behavior of the heart.

    PubMed

    Tavakolian, Kouhyar; Zadeh, Faranak M; Chuo, Yindar; Siu, Tiffany; Vaseghi, Ali; Kaminska, Bozena

    2008-01-01

    In this paper a novel system for detection of the mechanical movement of heart, mechanocardiography (MCG), with no connection to the subject's body is presented. This signal is based on radar technology. The acquired signal is highly correlated to the acceleration-based ballistocardiograph signal (BCG) recorded directly from the sternum. It is shown that the heart and breathing rates can be reliably detected using this system.

  16. Fishing in the Water: Effect of Sampled Water Volume on Environmental DNA-Based Detection of Macroinvertebrates.

    PubMed

    Mächler, Elvira; Deiner, Kristy; Spahn, Fabienne; Altermatt, Florian

    2016-01-05

    Accurate detection of organisms is crucial for the effective management of threatened and invasive species because false detections directly affect the implementation of management actions. The use of environmental DNA (eDNA) as a species detection tool is in a rapid development stage; however, concerns about accurate detections using eDNA have been raised. We evaluated the effect of sampled water volume (0.25 to 2 L) on the detection rate for three macroinvertebrate species. Additionally, we tested (depending on the sampled water volume) what amount of total extracted DNA should be screened to reduce uncertainty in detections. We found that all three species were detected in all volumes of water. Surprisingly, however, only one species had a positive relationship between an increased sample volume and an increase in the detection rate. We conclude that the optimal sample volume might depend on the species-habitat combination and should be tested for the system where management actions are warranted. Nevertheless, we minimally recommend sampling water volumes of 1 L and screening at least 14 μL of extracted eDNA for each sample to reduce uncertainty in detections when studying macroinvertebrates in rivers and using our molecular workflow.

  17. Effect of directional speech warnings on road hazard detection.

    PubMed

    Serrano, Jesús; Di Stasi, Leandro L; Megías, Alberto; Catena, Andrés

    2011-12-01

    In the last 2 decades, cognitive science and the transportation psychology field have dedicated a lot of effort to designing advanced driver support systems. Verbal warning systems are increasingly being implemented in modern automobiles in an effort to increase road safety. The study presented here investigated the impact of directional speech alert messages on the participants' speed to judge whether or not naturalistic road scenes depicted a situation of impending danger. Thirty-eight volunteers performed a computer-based key-press reaction time task. Findings indicated that semantic content of verbal warning signals can be used for increasing driving safety and improving hazard detection. Furthermore, the classical result regarding signal accuracy is confirmed: directional informative speech messages lead to faster hazard detection compared to drivers who received a high rate of false alarms. Notwithstanding some study limitations (lack of driver experience and low ecological validity), this evidence could provide important information for the specification of future Human-Machine-interaction (HMI) design guidelines.

  18. Hunting for Dark Matter particles with new detectors.

    PubMed

    Angloher, Godehard; Jochum, Josef

    2005-03-01

    Although first hints of the existence of Dark Matter were observed by the Swiss astronomer Zwicky already in the 1930s, only in recent years has it become known that the universe, in fact, is dominated by particles whose nature is almost unknown and which have never been directly observed. Meanwhile, as the existence of these particles is postulated not only by astronomy, but also cosmology and theoretical particle physics, there is significant effort to detect them in a laboratory experiment and determine their physical properties. However, as the interaction rate between Dark Matter particles and ordinary matter is extremely low, detectors have to be extremely sensitive. Low temperature detectors have been available for more than a decade and have now reached the highest sensitivity for direct Dark Matter detection. In this article, we give a short overview of observational results that suggest the existence of Dark Matter particles and what physicists have learned so far about their properties. The main focus is on the experimental challenges and effort for their direct detection.

  19. Direct bit detection receiver noise performance analysis for 32-PSK and 64-PSK modulated signals

    NASA Astrophysics Data System (ADS)

    Ahmed, Iftikhar

    1987-12-01

    Simple two channel receivers for 32-PSK and 64-PSK modulated signals have been proposed which allow digital data (namely bits), to be recovered directly instead of the traditional approach of symbol detection followed by symbol to bit mappings. This allows for binary rather than M-ary receiver decisions, reduces the amount of signal processing operations and permits parallel recovery of the bits. The noise performance of these receivers quantified by the Bit Error Rate (BER) assuming an Additive White Gaussian Noise interference model is evaluated as a function of Eb/No, the signal to noise ratio, and transmitted phase angles of the signals. The performance results of the direct bit detection receivers (DBDR) when compared to that of convectional phase measurement receivers demonstrate that DBDR's are optimum in BER sense. The simplicity of the receiver implementations and the BER of the delivered data make DBDR's attractive for high speed, spectrally efficient digital communication systems.

  20. GMR-based eddy current probe for weld seam inspection and its non-scanning detection study

    NASA Astrophysics Data System (ADS)

    Gao, Peng; Wang, Chao; Li, Yang; Wang, Libin; Cong, Zheng; Zhi, Ya

    2017-04-01

    Eddy current testing is one of the most important non-destructive testing methods for welding defects detection. This paper presents the use of a probe consisting of 4 giant magneto-resistive (GMR) sensors to detect weld defects. Information from four measuring points above and on both sides of the weld seam is collected at the same time. By setting the GMR sensors' sensing axes perpendicular to the direction of the excitation magnetic field, the information collected mainly reflects the change in the eddy current which is caused by defects. Digital demodulation technology is applied to extract the real part and imaginary part of the GMR sensors' output signals. The variables containing directional information of the magnetic field are introduced. Based on the data from the four GMR (4-GMR) sensors' output signals, four values, Ran, Mean, Var and k are selected as the feature quantities for defect recognition. Experiments are carried out on weld seams with and without defects, and the detection outputs are given in this paper. The 4-GMR probe is also employed to investigate non-scanning weld defect detection and the four feature quantities (Ran, Mean, Var and k) are studied to evaluate weld quality. The non-scanning weld defect detection is presented. A support vector machine is used to classify and discriminate welds with and without defects. Experiments carried out show that through the method in this paper, the recognition rate is 92% for welds without defects and 90% for welds with defects, with an overall recognition rate of 90.9%, indicating that this method could effectively detect weld defects.

  1. Cross Sections, relic abundance, and detection rates for neutralino dark matter

    NASA Technical Reports Server (NTRS)

    Griest, Kim

    1988-01-01

    Neutralino annihilation and elastic scattering cross sections are derived which differ in important ways from previous work. These are applied to relic abundance calculations and to direct detection of neutralino dark matter from the galactic halo. Assuming the neutralino to be the lightest supersymmetric particle and that it is less massive than the Z sup 0, we find relic densities of neutralinos greater than 4 percent of critical density for almost all values of the supersymmetric parameters. We constrain the parameter space by using results from PETRA (chargino mass less than 23 GeV) and ASP, and then assuming a critical density of neutralinos, display event rates in a cryogenic detector for a variety of models. A new term implies spin independent elastic scattering even for those majorana particles and inclusion of propagator momenta increases detection rates by 10 to 300 percent for pure photinos. Z sup 0-squark interference leads to very low detection rates for some values of the parameters. The new term in the elastic cross section dominates for heavy, mostly spinless materials and mitigates the negative interference cancellations in light materials; except for the pure photino or pure higgsinos cases where it does not contribute. In general, the rates can be substantially different from the pure photino and pure higgsino special cases usually considered.

  2. Spatio-temporal variation in click production rates of beaked whales: Implications for passive acoustic density estimation.

    PubMed

    Warren, Victoria E; Marques, Tiago A; Harris, Danielle; Thomas, Len; Tyack, Peter L; Aguilar de Soto, Natacha; Hickmott, Leigh S; Johnson, Mark P

    2017-03-01

    Passive acoustic monitoring has become an increasingly prevalent tool for estimating density of marine mammals, such as beaked whales, which vocalize often but are difficult to survey visually. Counts of acoustic cues (e.g., vocalizations), when corrected for detection probability, can be translated into animal density estimates by applying an individual cue production rate multiplier. It is essential to understand variation in these rates to avoid biased estimates. The most direct way to measure cue production rate is with animal-mounted acoustic recorders. This study utilized data from sound recording tags deployed on Blainville's (Mesoplodon densirostris, 19 deployments) and Cuvier's (Ziphius cavirostris, 16 deployments) beaked whales, in two locations per species, to explore spatial and temporal variation in click production rates. No spatial or temporal variation was detected within the average click production rate of Blainville's beaked whales when calculated over dive cycles (including silent periods between dives); however, spatial variation was detected when averaged only over vocal periods. Cuvier's beaked whales exhibited significant spatial and temporal variation in click production rates within vocal periods and when silent periods were included. This evidence of variation emphasizes the need to utilize appropriate cue production rates when estimating density from passive acoustic data.

  3. A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring.

    PubMed

    Brueck, Andrew; Iftekhar, Tashfin; Stannard, Alicja B; Yelamarthi, Kumar; Kaya, Tolga

    2018-02-10

    There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 µL/min/cm², with an average error in accuracy of 18% compared to manual sweat rate readings.

  4. Review: Prevalence and dynamics of Helicobacter pylori infection during childhood.

    PubMed

    Zabala Torrres, Beatriz; Lucero, Yalda; Lagomarcino, Anne J; Orellana-Manzano, Andrea; George, Sergio; Torres, Juan P; O'Ryan, Miguel

    2017-10-01

    Long-term persistent Helicobacter pylori infection has been associated with ulceropeptic disease and gastric cancer. Although H. pylori is predominantly acquired early in life, a clear understanding of infection dynamics during childhood has been obfuscated by the diversity of populations evaluated, study designs, and methods used. Update understanding of true prevalence of H. pylori infection during childhood, based on a critical analysis of the literature published in the past 5 years. Comprehensive review and meta-analysis of original studies published from 2011 to 2016. A MEDLINE ® /PubMed ® search on May 1, 2016, using the terms pylori and children, and subsequent exclusion, based on abstract review using predefined criteria, resulted in 261 citations. An Embase ® search with the same criteria added an additional 8 citations. In healthy children, meta-analysis estimated an overall seroprevalence rate of 33% (95% CI: 27%-38%). Seven healthy cohort studies using noninvasive direct detection methods showed infection prevalence estimates ranging from 20% to 50% in children ≤5 and 38% to 79% in children >5 years. The probability of infection persistence after a first positive sample ranged from 49% to 95%. Model estimates of cross-sectional direct detection studies in asymptomatic children indicated a prevalence of 37% (95% CI: 30%-44%). Seroprevalence, but not direct detection rates increased with age; both decreased with increasing income. The model estimate based on cross-sectional studies in symptomatic children was 39% (95% CI: 35%-43%). The prevalence of H. pylori infection varied widely in the studies included here; nevertheless, model estimates by detection type were similar, suggesting that overall, one-third of children worldwide are or have been infected. The few cohort and longitudinal studies available show variability, but most studies, show infection rates over 30%. Rather surprisingly, overall infection prevalence in symptomatic children was only slightly higher, around 40%. Studies including only one positive stool sample should be interpreted with caution as spontaneous clearance can occur. © 2017 John Wiley & Sons Ltd.

  5. Aseismic fold growth in southwestern Taiwan detected by InSAR and GNSS

    NASA Astrophysics Data System (ADS)

    Tsukahara, Kotaro; Takada, Youichiro

    2018-03-01

    We report very rapid and aseismic fold growth detected by L-band InSAR images and GNSS data in southwestern Taiwan where is characterized by high convergence rate and low seismicity. Six independent interferograms acquired from ascending orbit during 2007-2011 commonly indicate large line-of-sight (LOS) shortening. For descending orbit, one interferogram spanning 21 months also indicates the LOS shortening at the same location. After removing long-wavelength noise and height-dependent phase component from these interferograms using GNSS velocity field and DEM, we obtained the quasi-vertical and the quasi-east velocity fields. We found very rapid uplift (quasi-vertical movement) in the fold and thrust belt to the east of the Tainan city. The uplifted area stretches about 25 km in the N-S direction and about 5 km in the E-W direction. At the southern part of the uplifted area, the uplift rate obtained by InSAR is consistent with that measured by the leveling survey, which takes 18 mm/year at a maximum. On the other hand, at the northern part, the maximum uplift rate detected by InSAR reaches up to 37 mm/year, more than twice as large as the rate along the levelling route. Judging from very low seismicity in this region, the severe crustal deformation we detected with InSAR is aseismic. At the eastern flank of the uplifted area, we found a sharp discontinuity in the uplift rate from the ALOS/PALSAR interferometry, and a sharp discontinuity in the amount of uplift in response to the 2016 Meinong earthquake (M6.4) from ALOS-2/PALSAR2 interferometry, which implies the existence of a shallow active fault. The stable slip of this active fault would be due to the high pore fluid pressure reported in this region. The aseismic uplift before the Meinong earthquake would be mainly due to the mud diapirs at the depth, which is perturbed by the aseismic movement of the shallow active fault.

  6. Solar neutrino detection in a large volume double-phase liquid argon experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franco, D.; Agnes, P.; Giganti, C.

    2016-08-01

    Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne-yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all threemore » cartesian directions. While enabling Dark Matter searches with sensitivity extending to the ''neutrino floor'' (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ∼15% precision, and significantly improve the precision of the {sup 7}Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.« less

  7. Stop co-annihilation in the minimal supersymmetric standard model revisited

    NASA Astrophysics Data System (ADS)

    Pierce, Aaron; Shah, Nausheen R.; Vogl, Stefan

    2018-01-01

    We reexamine the stop co-annihilation scenario of the minimal supersymmetric standard model, wherein a binolike lightest supersymmetric particle has a thermal relic density set by co-annihilations with a scalar partner of the top quark in the early universe. We concentrate on the case where only the top partner sector is relevant for the cosmology, and other particles are heavy. We discuss the cosmology with focus on low energy parameters and an emphasis on the implications of the measured Higgs boson mass and its properties. We find that the irreducible direct detection signal correlated with this cosmology is generically well below projected experimental sensitivity, and in most cases lies below the neutrino background. A larger, detectable, direct detection rate is possible, but is unrelated to the co-annihilation cosmology. LHC searches for compressed spectra are crucial for probing this scenario.

  8. Comparative performance analysis for computer aided lung nodule detection and segmentation on ultra-low-dose vs. standard-dose CT

    NASA Astrophysics Data System (ADS)

    Wiemker, Rafael; Rogalla, Patrik; Opfer, Roland; Ekin, Ahmet; Romano, Valentina; Bülow, Thomas

    2006-03-01

    The performance of computer aided lung nodule detection (CAD) and computer aided nodule volumetry is compared between standard-dose (70-100 mAs) and ultra-low-dose CT images (5-10 mAs). A direct quantitative performance comparison was possible, since for each patient both an ultra-low-dose and a standard-dose CT scan were acquired within the same examination session. The data sets were recorded with a multi-slice CT scanner at the Charite university hospital Berlin with 1 mm slice thickness. Our computer aided nodule detection and segmentation algorithms were deployed on both ultra-low-dose and standard-dose CT data without any dose-specific fine-tuning or preprocessing. As a reference standard 292 nodules from 20 patients were visually identified, each nodule both in ultra-low-dose and standard-dose data sets. The CAD performance was analyzed by virtue of multiple FROC curves for different lower thresholds of the nodule diameter. For nodules with a volume-equivalent diameter equal or larger than 4 mm (149 nodules pairs), we observed a detection rate of 88% at a median false positive rate of 2 per patient in standard-dose images, and 86% detection rate in ultra-low-dose images, also at 2 FPs per patient. Including even smaller nodules equal or larger than 2 mm (272 nodules pairs), we observed a detection rate of 86% in standard-dose images, and 84% detection rate in ultra-low-dose images, both at a rate of 5 FPs per patient. Moreover, we observed a correlation of 94% between the volume-equivalent nodule diameter as automatically measured on ultra-low-dose versus on standard-dose images, indicating that ultra-low-dose CT is also feasible for growth-rate assessment in follow-up examinations. The comparable performance of lung nodule CAD in ultra-low-dose and standard-dose images is of particular interest with respect to lung cancer screening of asymptomatic patients.

  9. Strategies for halting the rise of multidrug resistant TB epidemics: assessing the effect of early case detection and isolation.

    PubMed

    Espindola, Aquino L; Varughese, Marie; Laskowski, Marek; Shoukat, Affan; Heffernan, Jane M; Moghadas, Seyed M

    2017-03-01

    The increasing rates of multidrug resistant TB (MDR-TB) have posed the question of whether control programs under enhanced directly observed treatment, short-course (DOTS-Plus) are sufficient or implemented optimally. Despite enhanced efforts on early case detection and improved treatment regimens, direct transmission of MDR-TB remains a major hurdle for global TB control. We developed an agent-based simulation model of TB dynamics to evaluate the effect of transmission reduction measures on the incidence of MDR-TB. We implemented a 15-day isolation period following the start of treatment in active TB cases. The model was parameterized with the latest estimates derived from the published literature. We found that if high rates (over 90%) of TB case identification are achieved within 4 weeks of developing active TB, then a 15-day patient isolation strategy with 50% effectiveness in interrupting disease transmission leads to 10% reduction in the incidence of MDR-TB over 10 years. If transmission is fully prevented, the rise of MDR-TB can be halted within 10 years, but the temporal reduction of MDR-TB incidence remains below 20% in this period. The impact of transmission reduction measures on the TB incidence depends critically on the rates and timelines of case identification. The high costs and adverse effects associated with MDR-TB treatment warrant increased efforts and investments on measures that can interrupt direct transmission through early case detection. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Effectiveness of medicines authentication technology to detect counterfeit, recalled and expired medicines: a two-stage quantitative secondary care study

    PubMed Central

    Naughton, Bernard; Roberts, Lindsey; Dopson, Sue; Chapman, Stephen; Brindley, David

    2016-01-01

    Objectives To identify the authentication and detection rate of serialised medicines using medicines authentication technology. Design and intervention 4192 serialised medicines were entered into a hospital dispensary over two separate 8-week stages in 2015. Medicines were authenticated using secure external database cross-checking, triggered by the scanning of a two-dimensional data matrix with a unit specific 12-digit serial code. 4% of medicines included were preprogrammed with a message to identify the product as either expired, pack recalled, product recalled or counterfeit. Setting A site within a large UK National Health Service teaching hospital trust. Participants Accredited checking staff, pharmacists and dispensers in a pharmacy department. Primary outcome measures Authentication and detection rate of counterfeit expired and recalled medicines. Results The operational detection rate of counterfeit, recalled and expired medicines scanned as a combined group was 81.4% (stage 1 (S1)) and 87% (stage 2 (S2)). The technology's technical detection rate (TDR) was 100%; however, not all medicines were scanned and of those that were scanned not all that generated a warning message were quarantined. Owing to an operational authentication rate (OAR) of 66.3% (over both stages), only 31.8% of counterfeit medicines, 58% of recalled drugs and 64% of expired medicines were detected as a proportion of those entered into the study. Response times (RTs) of 152 ms (S1) and 165 ms (S2) were recorded, meeting the falsified medicines directive-mandated 300 ms limit. Conclusions TDRs and RTs were not a limiting factor in this study. The suboptimal OAR poses significant quality and safety issues with this detection approach. Authentication at the checking stage, however, demonstrated higher OARs. There is a need for further qualitative research to establish the reasons for less than absolute authentication and detection rates in the hospital environment to improve this technology in preparation for the incumbent European Union regulative deadline. PMID:27940634

  11. Direct detection of time-resolved Rabi oscillations in a single quantum dot via resonance fluorescence

    NASA Astrophysics Data System (ADS)

    Schaibley, J. R.; Burgers, A. P.; McCracken, G. A.; Steel, D. G.; Bracker, A. S.; Gammon, D.; Sham, L. J.

    2013-03-01

    Optical Rabi oscillations are coherent population oscillations of a two-level system coupled by an electric dipole transition when driven by a strong nearly resonant optical field. In quantum dot structures, these measurements have typically been performed as a function of the total pulse area ∫Ω0(t)dt where the pulse area varies as a function of Rabi frequency. Here, we report direct detection of the time-resolved coherent transient response of the resonance fluorescence to measure the time evolution of the optical Rabi oscillations in a single charged InAs quantum dot. We extract a decoherence rate consistent with the limit from the excited state lifetime.

  12. Directly and indirectly detected through-bond heteronuclear correlation solid-state NMR spectroscopy under fast MAS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, Kanmi; Pruski, Marek

    Two-dimensional through-bond {sup 1}H({sup 13}C) solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse {sup 1}H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of {sup 1}H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N-formyl-l-methionyl-l-leucyl-l-phenylalanine (f-MLF-OH) and brown coal.

  13. Directly and indirectly detected through-bond heteronuclear correlation solid-state NMR spectroscopy under fast MAS

    NASA Astrophysics Data System (ADS)

    Mao, Kanmi; Pruski, Marek

    2009-12-01

    Two-dimensional through-bond 1H{ 13C} solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse 1H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of 1H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N- formyl- L-methionyl- L-leucyl- L-phenylalanine (f-MLF-OH) and brown coal.

  14. Track Detection in Railway Sidings Based on MEMS Gyroscope Sensors

    PubMed Central

    Broquetas, Antoni; Comerón, Adolf; Gelonch, Antoni; Fuertes, Josep M.; Castro, J. Antonio; Felip, Damià; López, Miguel A.; Pulido, José A.

    2012-01-01

    The paper presents a two-step technique for real-time track detection in single-track railway sidings using low-cost MEMS gyroscopes. The objective is to reliably know the path the train has taken in a switch, diverted or main road, immediately after the train head leaves the switch. The signal delivered by the gyroscope is first processed by an adaptive low-pass filter that rejects noise and converts the temporal turn rate data in degree/second units into spatial turn rate data in degree/meter. The conversion is based on the travelled distance taken from odometer data. The filter is implemented to achieve a speed-dependent cut-off frequency to maximize the signal-to-noise ratio. Although direct comparison of the filtered turn rate signal with a predetermined threshold is possible, the paper shows that better detection performance can be achieved by processing the turn rate signal with a filter matched to the rail switch curvature parameters. Implementation aspects of the track detector have been optimized for real-time operation. The detector has been tested with both simulated data and real data acquired in railway campaigns. PMID:23443376

  15. Comparison of Detection Rate and Mutational Pattern of Drug-Resistant Mutations Between a Large Cohort of Genotype B and Genotype C Hepatitis B Virus-Infected Patients in North China.

    PubMed

    Li, Xiaodong; Liu, Yan; Xin, Shaojie; Ji, Dong; You, Shaoli; Hu, Jinhua; Zhao, Jun; Wu, Jingjing; Liao, Hao; Zhang, Xin-Xin; Xu, Dongping

    2017-06-01

    The study aimed to investigate the association of prevalent genotypes in China (HBV/C and HBV/B) with HBV drug-resistant mutations. A total of 13,847 nucleos(t)ide analogue (NA)-treated patients with chronic HBV infection from North China were enrolled. HBV genotypes and resistant mutations were determined by direct sequencing and confirmed by clonal sequencing if necessary. HBV/B, HBV/C, and HBV/D occupied 14.3%, 84.9%, and 0.8% across the study population, respectively. NA usage had no significant difference between HBV/B- and HBV/C-infected patients. Lamivudine-resistant mutations were more frequently detected in HBV/C-infected patients, compared with HBV/B-infected patients (31.67% vs. 25.26%, p < 0.01). Adefovir- and entecavir-resistant mutation detection rates were similar, but the mutational pattern was different between the two genotypes. For adefovir-resistant mutations, HBV/C-infected patients had a higher detection rate of rtA181 V (HBV/C 5.29% vs. HBV/B 1.36%, p < 0.01) and a lower detection rate of rtN236T (2.70% vs. 6.54%, p < 0.01). For entecavir-resistant mutations, HBV/C-infected patients had a higher detection rate of rtM204 V/I+T184 substitution or S202G/C (3.66% vs. 2.16%, p < 0.01) and a lower detection rate of rtM204 V/I+M250 V/I/L substitution (0.67% vs. 1.46%, p < 0.01). Multidrug-resistant mutations (defined as coexistence of mutation to nucleoside and nucleotide analogues) were detected in 104 patients. HBV/C-infected patients had a higher detection rate of multidrug-resistant mutation than HBV/B-infected patients (0.83% vs. 0.35%, p < 0.05). The study for the first time clarified that HBV/C-infected patients had a higher risk to develop multidrug-resistant mutations, compared with HBV/B-infected patients; and HBV/C- and HBV/B-infected patients had different inclinations in the ETV-resistant mutational pattern.

  16. Detection of influenza-like illness aberrations by directly monitoring Pearson residuals of fitted negative binomial regression models.

    PubMed

    Chan, Ta-Chien; Teng, Yung-Chu; Hwang, Jing-Shiang

    2015-02-21

    Emerging novel influenza outbreaks have increasingly been a threat to the public and a major concern of public health departments. Real-time data in seamless surveillance systems such as health insurance claims data for influenza-like illnesses (ILI) are ready for analysis, making it highly desirable to develop practical techniques to analyze such readymade data for outbreak detection so that the public can receive timely influenza epidemic warnings. This study proposes a simple and effective approach to analyze area-based health insurance claims data including outpatient and emergency department (ED) visits for early detection of any aberrations of ILI. The health insurance claims data during 2004-2009 from a national health insurance research database were used for developing early detection methods. The proposed approach fitted the daily new ILI visits and monitored the Pearson residuals directly for aberration detection. First, negative binomial regression was used for both outpatient and ED visits to adjust for potentially influential factors such as holidays, weekends, seasons, temporal dependence and temperature. Second, if the Pearson residuals exceeded 1.96, aberration signals were issued. The empirical validation of the model was done in 2008 and 2009. In addition, we designed a simulation study to compare the time of outbreak detection, non-detection probability and false alarm rate between the proposed method and modified CUSUM. The model successfully detected the aberrations of 2009 pandemic (H1N1) influenza virus in northern, central and southern Taiwan. The proposed approach was more sensitive in identifying aberrations in ED visits than those in outpatient visits. Simulation studies demonstrated that the proposed approach could detect the aberrations earlier, and with lower non-detection probability and mean false alarm rate in detecting aberrations compared to modified CUSUM methods. The proposed simple approach was able to filter out temporal trends, adjust for temperature, and issue warning signals for the first wave of the influenza epidemic in a timely and accurate manner.

  17. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST)

    NASA Astrophysics Data System (ADS)

    Friedman, Joshua I.; Xia, Ding; Regatte, Ravinder R.; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates ⩾ 30 s-1) while simultaneously eliminating signals originating from slower (∼5 s-1) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast.

  18. In quantum direct communication an undetectable eavesdropper can always tell Ψ from Φ Bell states in the message mode

    NASA Astrophysics Data System (ADS)

    Pavičić, Mladen

    2013-04-01

    We show that in any quantum direct communication protocol that is based on Ψ and Φ Bell states, an eavesdropper can always tell Ψ from Φ states without altering the transmission in any way in the message mode. This renders all protocols that make use of only one Ψ state and one Φ state completely insecure in the message mode. All four-Bell-state protocols require a revision and this might be of importance for new implementations of entanglement-based cryptographic protocols. The detection rate of an eavesdropper is 25% per control transmission, i.e., a half of the rate in the two-state (ping-pong) protocol. An eavesdropper can detect control probes with certainty in the standard control transmission without a photon in the Alice-to-Bob's travel mode and with near certainty in a transmission with a fake photon in the travel mode. Resending of measured control photons via the travel mode would make an eavesdropper completely invisible.

  19. Improving signal-to-noise in the direct imaging of exoplanets and circumstellar disks with MLOCI

    NASA Astrophysics Data System (ADS)

    Wahhaj, Zahed; Cieza, Lucas A.; Mawet, Dimitri; Yang, Bin; Canovas, Hector; de Boer, Jozua; Casassus, Simon; Ménard, François; Schreiber, Matthias R.; Liu, Michael C.; Biller, Beth A.; Nielsen, Eric L.; Hayward, Thomas L.

    2015-09-01

    We present a new algorithm designed to improve the signal-to-noise ratio (S/N) of point and extended source detections around bright stars in direct imaging data.One of our innovations is that we insert simulated point sources into the science images, which we then try to recover with maximum S/N. This improves the S/N of real point sources elsewhere in the field. The algorithm, based on the locally optimized combination of images (LOCI) method, is called Matched LOCI or MLOCI. We show with Gemini Planet Imager (GPI) data on HD 135344 B and Near-Infrared Coronagraphic Imager (NICI) data on several stars that the new algorithm can improve the S/N of point source detections by 30-400% over past methods. We also find no increase in false detections rates. No prior knowledge of candidate companion locations is required to use MLOCI. On the other hand, while non-blind applications may yield linear combinations of science images that seem to increase the S/N of true sources by a factor >2, they can also yield false detections at high rates. This is a potential pitfall when trying to confirm marginal detections or to redetect point sources found in previous epochs. These findings are relevant to any method where the coefficients of the linear combination are considered tunable, e.g., LOCI and principal component analysis (PCA). Thus we recommend that false detection rates be analyzed when using these techniques. Based on observations obtained at the Gemini Observatory, which is operated by the Association of Universities for Research in Astronomy, Inc., under a cooperative agreement with the NSF on behalf of the Gemini partnership: the National Science Foundation (USA), the Science and Technology Facilities Council (UK), the National Research Council (Canada), CONICYT (Chile), the Australian Research Council (Australia), Ministério da Ciência e Tecnologia (Brazil) and Ministerio de Ciencia, Tecnología e Innovación Productiva (Argentina).

  20. High mutation detection rate in TCOF1 among Treacher Collins syndrome patients reveals clustering of mutations and 16 novel pathogenic changes.

    PubMed

    Splendore, A; Silva, E O; Alonso, L G; Richieri-Costa, A; Alonso, N; Rosa, A; Carakushanky, G; Cavalcanti, D P; Brunoni, D; Passos-Bueno, M R

    2000-10-01

    Twenty-eight families with a clinical diagnosis of Treacher Collins syndrome were screened for mutations in the 25 coding exons of TCOF1 and their adjacent splice junctions through SSCP and direct sequencing. Pathogenic mutations were detected in 26 patients, yielding the highest detection rate reported so far for this disease (93%) and bringing the number of known disease-causing mutations from 35 to 51. This is the first report to describe clustering of pathogenic mutations. Thirteen novel polymorphic alterations were characterized, confirming previous reports that TCOF1 has an unusually high rate of single-nucleotide polymorphisms (SNPs) within its coding region. We suggest a possible different mechanism leading to TCS or genetic heterogeneity for this condition, as we identified two families with no apparent pathogenic mutation in the gene. Furthermore, our data confirm the absence of genotype-phenotype correlation and reinforce that the apparent anticipation often observed in TCS families is due to ascertainment bias. Copyright 2000 Wiley-Liss, Inc.

  1. Sensitive detection and estimation of cell-derived peroxynitrite fluxes using fluorescein-boronate.

    PubMed

    Rios, Natalia; Piacenza, Lucía; Trujillo, Madia; Martínez, Alejandra; Demicheli, Verónica; Prolo, Carolina; Álvarez, María Noel; López, Gloria V; Radi, Rafael

    2016-12-01

    The specific and sensitive detection of peroxynitrite (ONOO - /ONOOH) in biological systems is a great challenge due to its high reactivity towards several biomolecules. Herein, we validated the advantages of using fluorescein-boronate (Fl-B) as a highly sensitive fluorescent probe for the direct detection of peroxynitrite under biologically-relevant conditions in two different cell models. The synthesis of Fl-B was achieved by a very simply two-step conversion synthetic route with high purity (>99%) and overall yield (∼42%). Reactivity analysis of Fl-B with relevant biological oxidants including hydrogen peroxide (H 2 O 2 ), hypochlorous acid (HOCl) and peroxynitrite were performed. The rate constant for the reaction of peroxynitrite with Fl-B was 1.7×10 6 M -1 s -1 , a million times faster than the rate constant measured for H 2 O 2 (k=1.7M -1 s -1 ) and 2,700 faster than HOCl (6.2×10 2 M -1 s -1 ) at 37°C and pH 7.4. The reaction of Fl-B with peroxynitrite was significant even in the presence of physiological concentrations of CO 2 , a well-known peroxynitrite reactant. Experimental and simulated kinetic analyses confirm that the main oxidation process of Fl-B takes place with peroxynitrite itself via a direct bimolecular reaction and not with peroxynitrite-derived radicals. Fl-B was successfully applied for the detection of endogenously-generated peroxynitrite by endothelial cells and in macrophage-phagocyted parasites. Moreover, the generated data allowed estimating the actual intracellular flux of peroxynitrite. For instance, ionomycin-stimulated endothelial cells generated peroxynitrite at a rate of ∼ 0.1μMs -1 , while immunostimulated macrophages do so in the order of ∼1μMs -1 inside T. cruzi-infected phagosomes. Fl-B revealed not to be toxic in concentrations up to 1mM for 24h. Cellular peroxynitrite detection was achieved by conventional laboratory fluorescence-based methods including flow cytometry and epi-fluorescence microscopy. Fl-B was shown to be more sensitive than the coumarin boronate due to a higher molar absorption coefficient and quantum yield. Overall, our results show that Fl-B is a kinetically selective and highly sensitive probe for the direct detection of cell-derived peroxynitrite. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    PubMed

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level.

  3. Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings

    PubMed Central

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level. PMID:23516627

  4. A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring

    PubMed Central

    Brueck, Andrew; Iftekhar, Tashfin; Stannard, Alicja B.; Kaya, Tolga

    2018-01-01

    There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 µL/min/cm2, with an average error in accuracy of 18% compared to manual sweat rate readings. PMID:29439398

  5. Unveiling the hidden supernova population in local LIRGs with NIR/Radio observations

    NASA Astrophysics Data System (ADS)

    Herrero-Illana, R.; Pérez-Torres, M. A.; Alberdi, A.

    2013-05-01

    The dust enshrouded environments of Luminous Infrared Galaxies (LIRGs), and especially of their nuclear regions, prevents the direct detection of supernovae in the optical. Radio observations are unaffected by dust extinction, allowing for the detection of most of these supernovae, thus probing their massive star formation rate. In addition, complementary observations in the near IR can help us to understand the nature of these phenomena and derive properties of the regions where they occur.

  6. Improved Detection of Supernovae with the IceCube Observatory

    NASA Astrophysics Data System (ADS)

    Köpke, Lutz; "IceCube Collaboration1, Detection of soil erosion within pinyon-juniper woodlands using Thematic Mapper (TM) data

    NASA Technical Reports Server (NTRS)

    Price, Kevin P.

    1993-01-01

    Multispectral measurements collected by Landsat Thematic Mapper (TM) were correlated with field measurements, direct soil loss estimates, and Universal Soil Loss Equation (USLE) estimates to determine the sensitivity of TM data to varying degrees of soil erosion in pinyon-juniper woodland in central Utah. TM data were also evaluated as a predictor of the USLE Crop Management C factor for pinyon-juniper woodlands. TM spectral data were consistently better predictors of soil erosion factors than any combination of field factors. TM data were more sensitive to vegetation variations than the USLE C factor. USLE estimates showed low annual rates of erosion which varied little among the study sites. Direct measurements of rate of soil loss using the SEDIMENT (Soil Erosion DIrect measureMENT) technique, indicated high and varying rates of soil loss among the sites since tree establishment. Erosion estimates from the USLE and SEDIMENT methods suggest that erosion rates have been severe in the past, but because significant amounts of soil have already been eroded, and the surface is now armored by rock debris, present erosion rates are lower. Indicators of accelerated erosion were still present on all sites, however, suggesting that the USLE underestimated erosion within the study area.

  7. Evaluation of Xpert C. difficile, BD MAX Cdiff, IMDx C. difficile for Abbott m2000, and Illumigene C. difficile Assays for Direct Detection of Toxigenic Clostridium difficile in Stool Specimens.

    PubMed

    Shin, Bo-Moon; Yoo, Sun Mee; Shin, Won Chang

    2016-03-01

    We evaluated the performance of four commercial nucleic acid amplification tests (NAATs: Xpert C. difficile, BD MAX Cdiff, IMDx C. difficile for Abbott m2000, and Illumigene C. difficile) for direct and rapid detection of Clostridium difficile toxin genes. We compared four NAATs on the same set of 339 stool specimens (303 prospective and 36 retrospective specimens) with toxigenic culture (TC). Concordance rate among four NAATs was 90.3% (306/339). Based on TC results, the sensitivity and specificity were 90.0% and 92.9% for Xpert; 86.3% and 89.3% for Max; 84.3% and 94.4% for IMDx; and 82.4% and 93.7% for Illumigene, respectively. For 306 concordant cases, there were 11 TC-negative/NAATs co-positive cases and 6 TC-positive/NAATs co-negative cases. Among 33 discordant cases, 18 were only single positive in each NAAT (Xpert, 1; Max, 12; IMDx, 1; Illumigene, 4). Positivity rates of the four NAATs were associated with those of semi-quantitative cultures, which were maximized in grade 3 (>100 colony-forming unit [CFU]) compared with grade 1 (<10 CFU). Commercial NAATs may be rapid and reliable methods for direct detection of tcdA and/or tcdB in stool specimens compared with TC. Some differences in the sensitivity of the NAATs may partly depend on the number of toxigenic C. difficile in stool specimens.

  8. Changes in ecosystem resilience detected in automated measures of ecosystem metabolism during a whole-lake manipulation

    PubMed Central

    Batt, Ryan D.; Carpenter, Stephen R.; Cole, Jonathan J.; Pace, Michael L.; Johnson, Robert A.

    2013-01-01

    Environmental sensor networks are developing rapidly to assess changes in ecosystems and their services. Some ecosystem changes involve thresholds, and theory suggests that statistical indicators of changing resilience can be detected near thresholds. We examined the capacity of environmental sensors to assess resilience during an experimentally induced transition in a whole-lake manipulation. A trophic cascade was induced in a planktivore-dominated lake by slowly adding piscivorous bass, whereas a nearby bass-dominated lake remained unmanipulated and served as a reference ecosystem during the 4-y experiment. In both the manipulated and reference lakes, automated sensors were used to measure variables related to ecosystem metabolism (dissolved oxygen, pH, and chlorophyll-a concentration) and to estimate gross primary production, respiration, and net ecosystem production. Thresholds were detected in some automated measurements more than a year before the completion of the transition to piscivore dominance. Directly measured variables (dissolved oxygen, pH, and chlorophyll-a concentration) related to ecosystem metabolism were better indicators of the approaching threshold than were the estimates of rates (gross primary production, respiration, and net ecosystem production); this difference was likely a result of the larger uncertainties in the derived rate estimates. Thus, relatively simple characteristics of ecosystems that were observed directly by the sensors were superior indicators of changing resilience. Models linked to thresholds in variables that are directly observed by sensor networks may provide unique opportunities for evaluating resilience in complex ecosystems. PMID:24101479

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chien-Yi; Hill, Richard J.; Solon, Mikhail P.

    WIMP-nucleon scattering is analyzed at ordermore » $1/M$ in Heavy WIMP Effective Theory. The $1/M$ power corrections, where $$M\\gg m_W$$ is the WIMP mass, distinguish between different underlying UV models with the same universal limit and their impact on direct detection rates can be enhanced relative to naive expectations due to generic amplitude-level cancellations at leading order. The necessary one- and two-loop matching calculations onto the low-energy effective theory for WIMP interactions with Standard Model quarks and gluons are performed for the case of an electroweak SU(2) triplet WIMP, considering both the cases of elementary fermions and composite scalars. The low-velocity WIMP-nucleon scattering cross section is evaluated and compared with current experimental limits and projected future sensitivities. Our results provide the most robust prediction for electroweak triplet Majorana fermion dark matter direct detection rates; for this case, a cancellation between two sources of power corrections yields a small total $1/M$ correction, and a total cross section close to the universal limit for $$M \\gtrsim {\\rm few} \\times 100\\,{\\rm GeV}$$. For the SU(2) composite scalar, the $1/M$ corrections introduce dependence on underlying strong dynamics. Using a leading chiral logarithm evaluation, the total $1/M$ correction has a larger magnitude and uncertainty than in the fermionic case, with a sign that further suppresses the total cross section. These examples provide definite targets for future direct detection experiments and motivate large scale detectors capable of probing to the neutrino floor in the TeV mass regime.« less

  10. Changes in ecosystem resilience detected in automated measures of ecosystem metabolism during a whole-lake manipulation.

    PubMed

    Batt, Ryan D; Carpenter, Stephen R; Cole, Jonathan J; Pace, Michael L; Johnson, Robert A

    2013-10-22

    Environmental sensor networks are developing rapidly to assess changes in ecosystems and their services. Some ecosystem changes involve thresholds, and theory suggests that statistical indicators of changing resilience can be detected near thresholds. We examined the capacity of environmental sensors to assess resilience during an experimentally induced transition in a whole-lake manipulation. A trophic cascade was induced in a planktivore-dominated lake by slowly adding piscivorous bass, whereas a nearby bass-dominated lake remained unmanipulated and served as a reference ecosystem during the 4-y experiment. In both the manipulated and reference lakes, automated sensors were used to measure variables related to ecosystem metabolism (dissolved oxygen, pH, and chlorophyll-a concentration) and to estimate gross primary production, respiration, and net ecosystem production. Thresholds were detected in some automated measurements more than a year before the completion of the transition to piscivore dominance. Directly measured variables (dissolved oxygen, pH, and chlorophyll-a concentration) related to ecosystem metabolism were better indicators of the approaching threshold than were the estimates of rates (gross primary production, respiration, and net ecosystem production); this difference was likely a result of the larger uncertainties in the derived rate estimates. Thus, relatively simple characteristics of ecosystems that were observed directly by the sensors were superior indicators of changing resilience. Models linked to thresholds in variables that are directly observed by sensor networks may provide unique opportunities for evaluating resilience in complex ecosystems.

  11. Comparison of Zika virus (ZIKV) RNA detection in plasma, whole blood and urine - Case series of travel-associated ZIKV infection imported to Italy, 2016.

    PubMed

    Rossini, Giada; Gaibani, Paolo; Vocale, Caterina; Cagarelli, Roberto; Landini, Maria Paola

    2017-09-01

    The capability to detect ZIKV RNA is of crucial importance for cases confirmation. However, due to the short-lived viremia, the detection of ZIKV RNA in plasma/serum is challenging for samples collected more than one week after onset of clinical illness. We compared the window time and detection rate of ZIKV RNA in different specimen types (plasma, whole blood and urine) collected simultaneously at several times post-symptom onset. We examined the presence of ZIKV RNA in matched specimens of whole blood, plasma and urine collected in the same date (3-28 days after symptom onset) from 10 ZIKV infected patients. ZIKV RNA was found in plasma as late as 10 days after symptoms onset and tested positive in all 5 (100%) and in 2 of 6 (33,3%) plasma samples collected 1-5 and 6-10 days after symptoms onset, respectively. ZIKV RNA was positive in urine through the 21st day after symptom onset; the detection rate of ZIKV RNA in urine samples was 100% (11/11) for samples collected 1-10 days from symptoms onset, decreasing at later times of sampling. The detection rate of ZIKV RNA in whole blood was comparable to that in urine samples but extended the window of detection of ZIKV RNA up to 26 days after symptom onset. Our results highlight the usefulness of simultaneously testing multiple specimen types in order to extend the rate and the time frame of ZIKV RNA detection, increasing the possibility of cases confirmation through direct diagnosis in convalescence-phase of infection, supplementing serological data which are often difficult to interpret. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  12. Effects of platooning on signal-detection performance, workload, and stress: A driving simulator study.

    PubMed

    Heikoop, Daniël D; de Winter, Joost C F; van Arem, Bart; Stanton, Neville A

    2017-04-01

    Platooning, whereby automated vehicles travel closely together in a group, is attractive in terms of safety and efficiency. However, concerns exist about the psychological state of the platooning driver, who is exempted from direct control, yet remains responsible for monitoring the outside environment to detect potential threats. By means of a driving simulator experiment, we investigated the effects on recorded and self-reported measures of workload and stress for three task-instruction conditions: (1) No Task, in which participants had to monitor the road, (2) Voluntary Task, in which participants could do whatever they wanted, and (3) Detection Task, in which participants had to detect red cars. Twenty-two participants performed three 40-min runs in a constant-speed platoon, one condition per run in counterbalanced order. Contrary to some classic literature suggesting that humans are poor monitors, in the Detection Task condition participants attained a high mean detection rate (94.7%) and a low mean false alarm rate (0.8%). Results of the Dundee Stress State Questionnaire indicated that automated platooning was less distressing in the Voluntary Task than in the Detection Task and No Task conditions. In terms of heart rate variability, the Voluntary Task condition yielded a lower power in the low-frequency range relative to the high-frequency range (LF/HF ratio) than the Detection Task condition. Moreover, a strong time-on-task effect was found, whereby the mean heart rate dropped from the first to the third run. In conclusion, participants are able to remain attentive for a prolonged platooning drive, and the type of monitoring task has effects on the driver's psychological state. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. [Trend survey of ocular infections with bacteria at Toyama University Hospital over the past six years--from the standpoint of laboratory examination].

    PubMed

    Kubota, Tomomi; Hayashi, Shirou; Niimi, Hideki; Kitajima, Isao

    2012-07-01

    Specimens of bacterial ocular infections are frequently received in the clinical laboratory. However, a comprehensive trend survey of ocular infections with bacteria is very rare. Our objective is to understand the current tendency of ocular infections with bacteria in patients at Toyama University Hospital from the standpoint of laboratory examination. We studied 263 cases of ocular infection with bacteria diagnosed at Toyama University Hospital from January 2006 to December 2011. 123 were male and 140 were female, with a mean age of 61.2(0-98) years. Specimens were subjected to direct microscopy and culture. Cultures were positive in 174(66.2%) patients. The most common bacterial isolate was Staphylococcus (28.1%), followed by Corynebacterium (19.3%), Streptococcus (9.3%), and Propionibacterium (8.6%). MRSA accounted for 18.8% of all S. aureus isolates, and has increased in recent years. The number of bacteria detected was larger in March, June, July, August, and October. Age distribution indicated that around 70% of bacterial isolates were detected from patients over 60 years old. The most common specimen of ocular infections with bacteria was eye discharge (detection rate; 87.8%), followed by corneal scraping(41%), aqueous humor (19%), and vitreous body (27%). Nearly 80% of bacterial isolates were detected from patients with keratitis, endophthalmitis, dacryocystitis, and conjunctivitis. As for the disease specific detection rate, endophthalmitis was very low (38.3%). The detection rate by years indicated that the way doctors pick up the specimens greatly affects the detection rate. Based on this survey, we need close cooperation with medical doctors concerning laboratory examination in ocular infection with bacteria, and we must improve the detection sensitivity of specimens from patients with endophthalmitis.

  14. ESARR: enhanced situational awareness via road sign recognition

    NASA Astrophysics Data System (ADS)

    Perlin, V. E.; Johnson, D. B.; Rohde, M. M.; Lupa, R. M.; Fiorani, G.; Mohammad, S.

    2010-04-01

    The enhanced situational awareness via road sign recognition (ESARR) system provides vehicle position estimates in the absence of GPS signal via automated processing of roadway fiducials (primarily directional road signs). Sign images are detected and extracted from vehicle-mounted camera system, and preprocessed and read via a custom optical character recognition (OCR) system specifically designed to cope with low quality input imagery. Vehicle motion and 3D scene geometry estimation enables efficient and robust sign detection with low false alarm rates. Multi-level text processing coupled with GIS database validation enables effective interpretation even of extremely low resolution low contrast sign images. In this paper, ESARR development progress will be reported on, including the design and architecture, image processing framework, localization methodologies, and results to date. Highlights of the real-time vehicle-based directional road-sign detection and interpretation system will be described along with the challenges and progress in overcoming them.

  15. Antigen-Dissociation from Antibody-Modified Nanotransistor Sensor Arrays as a Direct Biomarker Detection Method in Unprocessed Biosamples.

    PubMed

    Krivitsky, Vadim; Zverzhinetsky, Marina; Patolsky, Fernando

    2016-10-12

    The detection of biomolecules is critical for a wide spectrum of applications in life sciences and medical diagnosis. Nonetheless, biosamples are highly complex solutions, which contain an enormous variety of biomolecules, cells, and chemical species. Consequently, the intrinsic chemical complexity of biosamples results in a significant analytical background noise and poses an immense challenge to any analytical measurement, especially when applied without prior efficient separation and purification steps. Here, we demonstrate the application of antigen-dissociation regime, from antibody-modified Si-nanowire sensors, as a simple and effective direct sensing mechanism of biomarkers of interest in complex biosamples, such as serum and untreated blood, which does not require ex situ time-consuming biosample manipulation steps, such as centrifugation, filtering, preconcentration, and desalting, thus overcoming the detrimental Debye screening limitation of nanowire-based biosensors. We found that two key parameters control the capability to perform quantitative biomarkers analysis in biosamples: (i) the affinity strength (k off rate) of the antibody-antigen recognition pair, which dictates the time length of the high-affinity slow dissociation subregime, and (ii) the "flow rate" applied during the solution exchange dissociation step, which controls the time width of the low-affinity fast-dissociation subregime. Undoubtedly, this is the simplest and most convenient approach for the SiNW FET-based detection of antigens in complex untreated biosamples. The lack of ex situ biosample manipulation time-consuming processes enhances the portability of the sensing platform and reduces to minimum the required volume of tested sample, as it allows the direct detection of untreated biosamples (5-10 μL blood or serum), while readily reducing the detection cycle duration to less than 5 min, factors of great importance in near-future point-of-care medical applications. We believe this is the first ever reported demonstration on the real-time, direct label-free sensing of biomarkers from untreated blood samples, using SiNW-based FET devices, while not compromising the ultrasensitive sensing capabilities inherent to these devices.

  16. DS/LPI autocorrelation detection in noise plus random-tone interference. [Direct Sequence Low-Probabilty of Intercept

    NASA Technical Reports Server (NTRS)

    Hinedi, S.; Polydoros, A.

    1988-01-01

    The authors present and analyze a frequency-noncoherent two-lag autocorrelation statistic for the wideband detection of random BPSK signals in noise-plus-random-multitone interference. It is shown that this detector is quite robust to the presence or absence of interference and its specific parameter values, contrary to the case of an energy detector. The rule assumes knowledge of the data rate and the active scenario under H0. It is concluded that the real-time autocorrelation domain and its samples (lags) are a viable approach for detecting random signals in dense environments.

  17. Event Detection for Hydrothermal Plumes: A case study at Grotto Vent

    NASA Astrophysics Data System (ADS)

    Bemis, K. G.; Ozer, S.; Xu, G.; Rona, P. A.; Silver, D.

    2012-12-01

    Evidence is mounting that geologic events such as volcanic eruptions (and intrusions) and earthquakes (near and far) influence the flow rates and temperatures of hydrothermal systems. Connecting such suppositions to observations of hydrothermal output is challenging, but new ongoing time series have the potential to capture such events. This study explores using activity detection, a technique modified from computer vision, to identify pre-defined events within an extended time series recorded by COVIS (Cabled Observatory Vent Imaging Sonar) and applies it to a time series, with gaps, from Sept 2010 to the present; available measurements include plume orientation, plume rise rate, and diffuse flow area at the NEPTUNE Canada Observatory at Grotto Vent, Main Endeavour Field, Juan de Fuca Ridge. Activity detection is the process of finding a pattern (activity) in a data set containing many different types of patterns. Among many approaches proposed to model and detect activities, we have chosen a graph-based technique, Petri Nets, as they do not require training data to model the activity. They use the domain expert's knowledge to build the activity as a combination of feature states and their transitions (actions). Starting from a conceptual model of how hydrothermal plumes respond to daily tides, we have developed a Petri Net based detection algorithm that identifies deviations from the specified response. Initially we assumed that the orientation of the plume would change smoothly and symmetrically in a consistent daily pattern. However, results indicate that the rate of directional changes varies. The present Petri Net detects unusually large and rapid changes in direction or amount of bending; however inspection of Figure 1 suggests that many of the events detected may be artifacts resulting from gaps in the data or from the large temporal spacing. Still, considerable complexity overlies the "normal" tidal response pattern (the data has a dominant frequency of ~12.9 hours). We are in the process of defining several events of particular scientific interest: 1) transient behavioral changes associated with atmospheric storms, earthquakes or volcanic intrusions or eruptions, 2) mutual interaction of neighboring plumes on each other's behavior, and 3) rapid shifts in plume direction that indicate the presence of unusual currents or changes in currents. We will query the existing data to see if these relationships are ever observed as well as testing our understanding of the "normal" pattern of response to tidal currents.Figure 1. Arrows indicate plume orientation at a given time (time axis in days after 9/29/10) and stars indicate times when orientation changes rapidly.

  18. Provocative radio transients and base rate bias: A Bayesian argument for conservatism

    NASA Astrophysics Data System (ADS)

    Hair, Thomas W.

    2013-10-01

    Most searches for alien radio transmissions have focused on finding omni-directional or purposefully earth-directed beams of enduring duration. However, most of the interesting signals so far detected have been transient and non-repeatable in nature. These signals could very well be the first data points in an ever-growing data base of such signals used to construct a probabilistic argument for the existence of extraterrestrial intelligence. This paper looks at the effect base rate bias could have on deciding which signals to include in such an archive based upon the likely assumption that our ability to discern natural from artificial signals will be less than perfect.

  19. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) for antigen detection of foot-and-mouth disease virus using clinical samples.

    PubMed

    Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru

    2014-01-01

    A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  1. Self-balanced real-time photonic scheme for ultrafast random number generation

    NASA Astrophysics Data System (ADS)

    Li, Pu; Guo, Ya; Guo, Yanqiang; Fan, Yuanlong; Guo, Xiaomin; Liu, Xianglian; Shore, K. Alan; Dubrova, Elena; Xu, Bingjie; Wang, Yuncai; Wang, Anbang

    2018-06-01

    We propose a real-time self-balanced photonic method for extracting ultrafast random numbers from broadband randomness sources. In place of electronic analog-to-digital converters (ADCs), the balanced photo-detection technology is used to directly quantize optically sampled chaotic pulses into a continuous random number stream. Benefitting from ultrafast photo-detection, our method can efficiently eliminate the generation rate bottleneck from electronic ADCs which are required in nearly all the available fast physical random number generators. A proof-of-principle experiment demonstrates that using our approach 10 Gb/s real-time and statistically unbiased random numbers are successfully extracted from a bandwidth-enhanced chaotic source. The generation rate achieved experimentally here is being limited by the bandwidth of the chaotic source. The method described has the potential to attain a real-time rate of 100 Gb/s.

  2. Applications of Elpasolites as a Multimode Radiation Sensor

    NASA Astrophysics Data System (ADS)

    Guckes, Amber

    This study consists of both computational and experimental investigations. The computational results enabled detector design selections and confirmed experimental results. The experimental results determined that the CLYC scintillation detector can be applied as a functional and field-deployable multimode radiation sensor. The computational study utilized MCNP6 code to investigate the response of CLYC to various incident radiations and to determine the feasibility of its application as a handheld multimode sensor and as a single-scintillator collimated directional detection system. These simulations include: • Characterization of the response of the CLYC scintillator to gamma-rays and neutrons; • Study of the isotopic enrichment of 7Li versus 6Li in the CLYC for optimal detection of both thermal neutrons and fast neutrons; • Analysis of collimator designs to determine the optimal collimator for the single CLYC sensor directional detection system to assay gamma rays and neutrons; Simulations of a handheld CLYC multimode sensor and a single CLYC scintillator collimated directional detection system with the optimized collimator to determine the feasibility of detecting nuclear materials that could be encountered during field operations. These nuclear materials include depleted uranium, natural uranium, low-enriched uranium, highly-enriched uranium, reactor-grade plutonium, and weapons-grade plutonium. The experimental study includes the design, construction, and testing of both a handheld CLYC multimode sensor and a single CLYC scintillator collimated directional detection system. Both were designed in the Inventor CAD software and based on results of the computational study to optimize its performance. The handheld CLYC multimode sensor is modular, scalable, low?power, and optimized for high count rates. Commercial?off?the?shelf components were used where possible in order to optimize size, increase robustness, and minimize cost. The handheld CLYC multimode sensor was successfully tested to confirm its ability for gamma-ray and neutron detection, and gamma?ray and neutron spectroscopy. The sensor utilizes wireless data transfer for possible radiation mapping and network?centric deployment. The handheld multimode sensor was tested by performing laboratory measurements with various gamma-ray sources and neutron sources. The single CLYC scintillator collimated directional detection system is portable, robust, and capable of source localization and identification. The collimator was designed based on the results of the computational study and is constructed with high density polyethylene (HDPE) and lead (Pb). The collimator design and construction allows for the directional detection of gamma rays and fast neutrons utilizing only one scintillator which is interchangeable. For this study, a CLYC-7 scintillator was used. The collimated directional detection system was tested by performing laboratory directional measurements with various gamma-ray sources, 252Cf and a 239PuBe source.

  3. Design of oil pipeline leak detection and communication system based on optical fiber technology

    NASA Astrophysics Data System (ADS)

    Tu, Yaqing; Chen, Huabo

    1999-08-01

    The integrity of oil pipeline is always a major concern of operators. Pipeline leak not only leads to loss of oil, but pollutes environment. A new pipeline leak detection and communication system based on optical fiber technology to ensure the pipeline reliability is presented. Combined direct leak detection method with an indirect one, the system will greatly reduce the rate of false alarm. According, to the practical features of oil pipeline,the pipeline communication system is designed employing the state-of-the-art optic fiber communication technology. The system has such feature as high location accuracy of leak detection, good real-time characteristic, etc. which overcomes the disadvantages of traditional leak detection methods and communication system effectively.

  4. STUDIES ON X-AGENT. III. EFFECT ON THE GROWTH OF SEEDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moriyama, H.

    1960-01-01

    The growth rate of seeds (grass and rape) was used to detect diurnal, seasonal, and directional variations in the intensity of this postulated cosmic radiation factor. As found earlier with bacteria, proximity to various materials changed the effect of the agent (cf. preceding abstract). (BBB)

  5. Europa's small impactor flux and seismic detection predictions

    NASA Astrophysics Data System (ADS)

    Tsuji, Daisuke; Teanby, Nicholas A.

    2016-10-01

    Europa is an attractive target for future lander missions due to its dynamic surface and potentially habitable sub-surface environment. Seismology has the potential to provide powerful new constraints on the internal structure using natural sources such as faults or meteorite impacts. Here we predict how many meteorite impacts are likely to be detected using a single seismic station on Europa to inform future mission planning efforts. To this end, we derive: (1) the current small impactor flux on Europa from Jupiter impact rate observations and models; (2) a crater diameter versus impactor energy scaling relation for icy moons by merging previous experiments and simulations; and (3) scaling relations for seismic signal amplitudes as a function of distance from the impact site for a given crater size, based on analogue explosive data obtained on Earth's ice sheets. Finally, seismic amplitudes are compared to predicted noise levels and seismometer performance to determine detection rates. We predict detection of 0.002-20 small local impacts per year based on P-waves travelling directly through the ice crust. Larger regional and global-scale impact events, detected through mantle-refracted waves, are predicted to be extremely rare (10-8-1 detections per year), so are unlikely to be detected by a short duration mission. Estimated ranges include uncertainties from internal seismic attenuation, impactor flux, and seismic amplitude scaling. Internal attenuation is the most significant unknown and produces extreme uncertainties in the mantle-refracted P-wave amplitudes. Our nominal best-guess attenuation model predicts 0.002-5 local direct P detections and 6 × 10-6-0.2 mantle-refracted detections per year. Given that a plausible Europa landed mission will only last around 30 days, we conclude that impacts should not be relied upon for a seismic exploration of Europa. For future seismic exploration, faulting due to stresses in the rigid outer ice shell is likely to be a much more viable mechanism for probing Europa's interior.

  6. Automatic streak endpoint localization from the cornerness metric

    NASA Astrophysics Data System (ADS)

    Sease, Brad; Flewelling, Brien; Black, Jonathan

    2017-05-01

    Streaked point sources are a common occurrence when imaging unresolved space objects from both ground- and space-based platforms. Effective localization of streak endpoints is a key component of traditional techniques in space situational awareness related to orbit estimation and attitude determination. To further that goal, this paper derives a general detection and localization method for streak endpoints based on the cornerness metric. Corners detection involves searching an image for strong bi-directional gradients. These locations typically correspond to robust structural features in an image. In the case of unresolved imagery, regions with a high cornerness score correspond directly to the endpoints of streaks. This paper explores three approaches for global extraction of streak endpoints and applies them to an attitude and rate estimation routine.

  7. Leak testing in parenteral packaging: establishment of direct correlation between helium leak rate measurements and microbial ingress for two different leak types.

    PubMed

    Morrical, Bradley D; Goverde, Marcel; Grausse, Jean; Gerwig, Tanja; Vorgrimler, Lothar; Morgen, Rachel; Büttiker, Jean-Pierre

    2007-01-01

    A direct test method using helium leak detection was developed to determine microbial ingress in parenteral vial/rubber closure systems. The purpose of this study was to establish a direct correlation between the helium leak rate and the presence of ingress when vials were submersed under pressure in a broth of bacteria. Results were obtained for two different types of leaks: microholes that have been laser-drilled into thin metal plates, and thin copper wire that was placed between the rubber closure and the glass vial's sealing surface. The results from the microholes showed that the helium leak rate was a function of the square of the hole diameter and fit well with theoretical calculations. The relationship with the wire gave a far more complex dependence and was not modeled theoretically. Comparison with the microbial challenge showed that for microholes a lower size limit was found to be 2 microm with a corresponding leak rate of 1.4 x 10(-3) mbarl/s. For the fine wire experiment the lower limit was 15-microm wire and a corresponding leak rate of 1.3 x 10(-5) mbarl/s. From these tests a safe, lower limit, leak rate was established.

  8. Methods for measuring exchangeable protons in glycosaminoglycans.

    PubMed

    Beecher, Consuelo N; Larive, Cynthia K

    2015-01-01

    Recent NMR studies of the exchangeable protons of GAGs in aqueous solution, including those of the amide, sulfamate, and hydroxyl moieties, have demonstrated potential for the detection of intramolecular hydrogen bonds, providing insights into secondary structure preferences. GAG amide protons are observable by NMR over wide pH and temperature ranges; however, specific solution conditions are required to reduce the exchange rate of the sulfamate and hydroxyl protons and allow their detection by NMR. Building on the vast body of knowledge on detection of hydrogen bonds in peptides and proteins, a variety of methods can be used to identify hydrogen bonds in GAGs including temperature coefficient measurements, evaluation of chemical shift differences between oligo- and monosaccharides, and relative exchange rates measured through line shape analysis and EXSY spectra. Emerging strategies to allow direct detection of hydrogen bonds through heteronuclear couplings offer promise for the future. Molecular dynamic simulations are important in this effort both to predict and confirm hydrogen bond donors and acceptors.

  9. Minimum viewing angle for visually guided ground speed control in bumblebees.

    PubMed

    Baird, Emily; Kornfeldt, Torill; Dacke, Marie

    2010-05-01

    To control flight, flying insects extract information from the pattern of visual motion generated during flight, known as optic flow. To regulate their ground speed, insects such as honeybees and Drosophila hold the rate of optic flow in the axial direction (front-to-back) constant. A consequence of this strategy is that its performance varies with the minimum viewing angle (the deviation from the frontal direction of the longitudinal axis of the insect) at which changes in axial optic flow are detected. The greater this angle, the later changes in the rate of optic flow, caused by changes in the density of the environment, will be detected. The aim of the present study is to examine the mechanisms of ground speed control in bumblebees and to identify the extent of the visual range over which optic flow for ground speed control is measured. Bumblebees were trained to fly through an experimental tunnel consisting of parallel vertical walls. Flights were recorded when (1) the distance between the tunnel walls was either 15 or 30 cm, (2) the visual texture on the tunnel walls provided either strong or weak optic flow cues and (3) the distance between the walls changed abruptly halfway along the tunnel's length. The results reveal that bumblebees regulate ground speed using optic flow cues and that changes in the rate of optic flow are detected at a minimum viewing angle of 23-30 deg., with a visual field that extends to approximately 155 deg. By measuring optic flow over a visual field that has a low minimum viewing angle, bumblebees are able to detect and respond to changes in the proximity of the environment well before they are encountered.

  10. Impact of three task demand factors on simulated unmanned system intelligence, surveillance, and reconnaissance operations.

    PubMed

    Abich, Julian; Reinerman-Jones, Lauren; Matthews, Gerald

    2017-06-01

    The present study investigated how three task demand factors influenced performance, subjective workload and stress of novice intelligence, surveillance, and reconnaissance operators within a simulation of an unmanned ground vehicle. Manipulations were task type, dual-tasking and event rate. Participants were required to discriminate human targets within a street scene from a direct video feed (threat detection [TD] task) and detect changes in symbols presented in a map display (change detection [CD] task). Dual-tasking elevated workload and distress, and impaired performance for both tasks. However, with increasing event rate, CD task deteriorated, but TD improved. Thus, standard workload models provide a better guide to evaluating the demands of abstract symbols than to processing realistic human characters. Assessment of stress and workload may be especially important in the design and evaluation of systems in which human character critical signals must be detected in video images. Practitioner Summary: This experiment assessed subjective workload and stress during threat and CD tasks performed alone and in combination. Results indicated an increase in event rate led to significant improvements in performance during TD, but decrements during CD, yet both had associated increases in workload and engagement.

  11. Swift and RXTE follow up observations of the transient currently active in the globular cluster Terzan 5

    NASA Astrophysics Data System (ADS)

    Altamirano, D.; Degenaar, N.; Heinke, C. O.; Homan, J.; Pooley, D.; Sivakoff, G. R.; Wijnands, R.

    2011-10-01

    Following the detection of an X-ray outburst in the direction of Terzan 5 (ATEL #3714), we obtained a Swift observation and additional RXTE observations. The XRT aboard Swift observed Terzan 5 on Oct. 26, 2011 in imaging mode for a total exposure time of 967 s. The source was detected at high count rates causing significant pile-up (the core is saturated), and a bad column intersects the point-spread function.

  12. Comparison of intraductal ultrasonography-directed and cholangiography-directed endoscopic retrograde biliary drainage in patients with a biliary obstruction.

    PubMed

    Rew, Soo-Jung; Lee, Du-Hyeon; Park, Chang-Hwan; Jeon, Jin; Kim, Hyun-Soo; Choi, Sung-Kyu; Rew, Jong-Sun

    2016-09-01

    Endoscopic retrograde biliary drainage (ERBD) has become a standard procedure in patients with a biliary obstruction. Intraductal ultrasonography (IDUS) has emerged as a new tool for managing extrahepatic biliary diseases. IDUS-directed ERBD can be performed without conventional cholangiography (CC). The goal of this study was to assess the effectiveness and safety of IDUS-directed ERBD compared to CC-directed ERBD in patients with an extrahepatic biliary obstruction. A total of 210 patients who had undergone IDUS-directed ERBD (IDUS-ERBD, n = 105) and CC-directed ERBD (CC-ERBD, n = 105) between October 2013 and April 2014 were analyzed retrospectively. The primary outcome measure was the procedural success rate. Secondary outcome measures included clinical outcomes, total procedure time, radiation exposure time, and overall complication rates. The total technical success rate of ERBD was 100% (105/105) in the IDUS-ERBD and CC-ERBD groups. Mean procedure time was slightly prolonged in the IDUS-ERBD group than that in the CC-ERBD group (32.1 ± 9.9 minutes vs. 28.4 ± 11.6 minutes, p = 0.023). Mean radiation exposure time was one-third less in the IDUS-ERBD group than that in the CC-ERBD group (28.0 ± 49.3 seconds vs. 94.2 ± 57.3 seconds, p < 0.001). No significant differences in complication rates were detected between the groups. IDUS-ERBD was equally effective and safe as CC-ERBD in patients with an extrahepatic biliary obstruction. Although IDUS-ERBD increased total procedure time, it significantly decreased radiation exposure.

  13. AGN-driven perturbations in the intracluster medium of the cool-core cluster ZwCl 2701

    NASA Astrophysics Data System (ADS)

    Vagshette, Nilkanth D.; Sonkamble, Satish S.; Naik, Sachindra; Patil, Madhav K.

    2016-09-01

    We present the results obtained from a total of 123 ks X-ray (Chandra) and 8 h of 1.4 GHz radio (Giant Metrewave Radio Telescope - GMRT) observations of the cool-core cluster ZwCl 2701 (z = 0.214). These observations of ZwCl 2701 showed the presence of an extensive pair of ellipsoidal cavities along the east and west directions within the central region < 20 kpc. Detection of bright rims around the cavities suggested that the radio lobes displaced X-ray-emitting hot gas forming shell-like structures. The total cavity power (mechanical power) that directly heated the surrounding gas and cooling luminosity of the cluster were estimated to be ˜2.27 × 1045 erg s-1 and 3.5 × 1044 erg s-1 , respectively. Comparable values of cavity power and cooling luminosity of ZwCl 2701 suggested that the mechanical power of the active galactic nuclei (AGN) outburst is large enough to balance the radiative cooling in the system. The star formation rate derived from the Hα luminosity was found to be ˜0.60 M⊙ yr-1, which is about three orders of magnitude lower than the cooling rate of ˜196 M⊙ yr-1. Detection of the floor in entropy profile of ZwCl 2701 suggested the presence of an alternative heating mechanism at the centre of the cluster. Lower value of the ratio (˜10-2) between black hole mass accretion rate and Eddington mass accretion rate suggested that launching of jet from the super massive black hole is efficient in ZwCl 2701. However, higher value of ratio (˜103) between black hole mass accretion rate and Bondi accretion rate indicated that the accretion rate required to create cavities is well above the Bondi accretion rate.

  14. Detection of Bordetella pertussis by rapid-cycle PCR and colorimetric microwell hybridization.

    PubMed Central

    Buck, G E

    1996-01-01

    The use of rapid-cycle PCR combined with colorimetric microwell hybridization for detecting Bordetella pertussis was investigated. Rapid cycling was performed with an air thermocycler (model 1605; Idaho Technology, Idaho Falls, Idaho). Although the instrument was originally designed to be used with capillary tubes, an adapter that allows this instrument to be used with PCR tubes has recently been introduced. Because of the low heat capacity of air, the thermocycler has rapid transition rates between temperatures. The combination of a rapid temperature transition rate, small sample volume (10 microliters), and overshooting or undershooting of the temperature set points allowed the cycles to be reduced to 5 s for denaturation and 10 s for extension and annealing. Thus, the amplification could be completed in a total of approximately 35 min. Amplified DNA was detected with biotin-labeled primers and by hybridization to a capture probe immobilized in microwell plates. When simulated clinical specimens consisting of pooled nasopharyngeal washes with known numbers of B. pertussis organisms were examined by this procedure, as little as one organism per 5 microliters of sample could be detected. Six nasopharyngeal aspirates or washes from culture-positive patients were positive by PCR, as were two of seven specimens obtained from patients that were negative by culture and direct fluorescent-antibody assay. The two patients who were PCR positive but culture and direct fluorescent-antibody assay negative had clinical disease compatible with pertussis. This method appears to be a sensitive, convenient means of detecting B. pertussis in clinical specimens. The total time required for specimen processing, amplification, and detection is about 2.5 h. PMID:8735080

  15. Risk assessment of false-positive quantitative real-time PCR results in food, due to detection of DNA originating from dead cells.

    PubMed

    Wolffs, Petra; Norling, Börje; Rådström, Peter

    2005-03-01

    Real-time PCR technology is increasingly used for detection and quantification of pathogens in food samples. A main disadvantage of nucleic acid detection is the inability to distinguish between signals originating from viable cells and DNA released from dead cells. In order to gain knowledge concerning risks of false-positive results due to detection of DNA originating from dead cells, quantitative PCR (qPCR) was used to investigate the degradation kinetics of free DNA in four types of meat samples. Results showed that the fastest degradation rate was observed (1 log unit per 0.5 h) in chicken homogenate, whereas the slowest rate was observed in pork rinse (1 log unit per 120.5 h). Overall results indicated that degradation occurred faster in chicken samples than in pork samples and faster at higher temperatures. Based on these results, it was concluded that, especially in pork samples, there is a risk of false-positive PCR results. This was confirmed in a quantitative study on cell death and signal persistence over a period of 28 days, employing three different methods, i.e. viable counts, direct qPCR, and finally floatation, a recently developed discontinuous density centrifugation method, followed by qPCR. Results showed that direct qPCR resulted in an overestimation of up to 10 times of the amount of cells in the samples compared to viable counts, due to detection of DNA from dead cells. However, after using floatation prior to qPCR, results resembled the viable count data. This indicates that by using of floatation as a sample treatment step prior to qPCR, the risk of false-positive PCR results due to detection of dead cells, can be minimized.

  16. Scaling single-wavelength optical interconnects to 180 Gb/s with PAM-M and pulse shaping

    NASA Astrophysics Data System (ADS)

    Dris, Stefanos; Bakopoulos, Paraskevas; Argyris, Nikolaos; Spatharakis, Christos; Avramopoulos, Hercules

    2016-03-01

    Faced with surging datacenter traffic demand, system designers are turning to multi-level optical modulation with direct detection as the means of reaching 100 Gb/s in a single optical lane; a further upgrade to 400 Gb/s is envisaged through wavelength-multiplexing of multiple 100 Gb/s strands. In terms of modulation formats, PAM-4 and PAM-8 are considered the front-runners, striking a good balance between bandwidth-efficiency and implementation complexity. In addition, the emergence of energy-efficient, high-speed CMOS digital-to-analog converters (DACs) opens up new possibilities: Spectral shaping through digital filtering will allow squeezing even more data through low-cost, low-bandwidth electro-optic components. In this work we demonstrate an optical interconnect based on an EAM that is driven directly with sub-volt electrical swing by a 65 GSa/s arbitrary waveform generator (AWG). Low-voltage drive is particularly attractive since it allows direct interfacing with the switch/server ASIC, eliminating the need for dedicated, power-hungry and expensive electrical drivers. Single-wavelength throughputs of 180 and 120 Gb/s are experimentally demonstrated with 60 Gbaud optical PAM-8 and PAM-4 respectively. Successful transmission over 1250 m SMF is achieved with direct-detection, using linear equalization via offline digital signal processing in order to overcome the strong bandwidth limitation of the overall link (~20 GHz). The suitability of Nyquist pulse shaping for optical interconnects is also investigated experimentally with PAM-4 and PAM-8, at a lower symbol rate of 40 Gbaud (limited by the sampling rate of the AWG). To the best of our knowledge, the rates achieved are the highest ever using optical PAM-M formats.

  17. High-speed and high-efficiency travelling wave single-photon detectors embedded in nanophotonic circuits

    PubMed Central

    Pernice, W.H.P.; Schuck, C.; Minaeva, O.; Li, M.; Goltsman, G.N.; Sergienko, A.V.; Tang, H.X.

    2012-01-01

    Ultrafast, high-efficiency single-photon detectors are among the most sought-after elements in modern quantum optics and quantum communication. However, imperfect modal matching and finite photon absorption rates have usually limited their maximum attainable detection efficiency. Here we demonstrate superconducting nanowire detectors atop nanophotonic waveguides, which enable a drastic increase of the absorption length for incoming photons. This allows us to achieve high on-chip single-photon detection efficiency up to 91% at telecom wavelengths, repeatable across several fabricated chips. We also observe remarkably low dark count rates without significant compromise of the on-chip detection efficiency. The detectors are fully embedded in scalable silicon photonic circuits and provide ultrashort timing jitter of 18 ps. Exploiting this high temporal resolution, we demonstrate ballistic photon transport in silicon ring resonators. Our direct implementation of a high-performance single-photon detector on chip overcomes a major barrier in integrated quantum photonics. PMID:23271658

  18. Time encoded radiation imaging

    DOEpatents

    Marleau, Peter; Brubaker, Erik; Kiff, Scott

    2014-10-21

    The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

  19. Multi-GNSS high-rate RTK, PPP and novel direct phase observation processing method: application to precise dynamic displacement detection

    NASA Astrophysics Data System (ADS)

    Paziewski, Jacek; Sieradzki, Rafal; Baryla, Radoslaw

    2018-03-01

    This paper provides the methodology and performance assessment of multi-GNSS signal processing for the detection of small-scale high-rate dynamic displacements. For this purpose, we used methods of relative (RTK) and absolute positioning (PPP), and a novel direct signal processing approach. The first two methods are recognized as providing accurate information on position in many navigation and surveying applications. The latter is an innovative method for dynamic displacement determination with the use of GNSS phase signal processing. This method is based on the developed functional model with parametrized epoch-wise topocentric relative coordinates derived from filtered GNSS observations. Current regular kinematic PPP positioning, as well as medium/long range RTK, may not offer coordinate estimates with subcentimeter precision. Thus, extended processing strategies of absolute and relative GNSS positioning have been developed and applied for displacement detection. The study also aimed to comparatively analyze the developed methods as well as to analyze the impact of combined GPS and BDS processing and the dependence of the results of the relative methods on the baseline length. All the methods were implemented with in-house developed software allowing for high-rate precise GNSS positioning and signal processing. The phase and pseudorange observations collected with a rate of 50 Hz during the field test served as the experiment’s data set. The displacements at the rover station were triggered in the horizontal plane using a device which was designed and constructed to ensure a periodic motion of GNSS antenna with an amplitude of ~3 cm and a frequency of ~4.5 Hz. Finally, a medium range RTK, PPP, and direct phase observation processing method demonstrated the capability of providing reliable and consistent results with the precision of the determined dynamic displacements at the millimeter level. Specifically, the research shows that the standard deviation of the displacement residuals obtained as the difference between a benchmark-ultra-short baseline RTK solution and selected scenarios ranged between 1.1 and 3.4 mm. At the same time, the differences in the mean amplitude of the oscillations derived from the established scenarios did not exceed 1.3 mm, whereas the frequency of the motion detected with the use of Fourier transformation was the same.

  20. Fermi Sees the Gamma Ray Sky

    NASA Image and Video Library

    2009-10-30

    This view of the gamma-ray sky constructed from one year of Fermi LAT observations is the best view of the extreme universe to date. The map shows the rate at which the LAT detects gamma rays with energies above 300 million electron volts -- about 120 million times the energy of visible light -- from different sky directions. Brighter colors equal higher rates. Credit: NASA/DOE/Fermi LAT Collaboration Full story: www.nasa.gov/mission_pages/GLAST/news/first_year.html

  1. [Rapid determination of trace iodate using monolithic column ion-pair chromatography coupled with direct conductivity detection].

    PubMed

    Liu, Yuzhen; Yu, Hong; Li, Siwen

    2011-10-01

    A method was developed on a monolithic column for the fast determination of trace iodate (IO(3)- ) by ion-pair chromatography with direct conductivity detection. The analytes were separated using a mobile phase of tetrabutylammonium hydroxide (TBA)-phthalic acid-acetonitrile on a reversed-phase silica-based monolithic column. The effects of eluent, flow rate and column temperature on the retention of iodate were investigated. The optimized chromatographic conditions for the determination of the anion were as follows: 0. 25 mmol/L TBA-0. 18 mmol/L phthalic acid-3% acetonitrile (pH 5.5) as mobile phase, a flow rate of 4.0 mL/min and a column temperature of 30 degrees C. Under the optimal conditions, retention time of iodate was less than 0. 5 min and the baseline separation of iodate was achieved without any interference by other anions (Cl-, NO , SO4(2)-, I- ). The detection limit (S/N= 3) was 0.36 mg/L for IO(3)- . Relative standard deviation (RSD, n = 5) of chromatographic peak area and retention time were 0. 35% and 0. 28%, respectively. The proposed method was applied to the determination of trace iodate in iodized medicine. The spiked recovery of iodate was 96. 4%. The method is rapid, simple, accurate, reliable, and practical.

  2. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST).

    PubMed

    Friedman, Joshua I; Xia, Ding; Regatte, Ravinder R; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates⩾30s(-1)) while simultaneously eliminating signals originating from slower (∼5s(-1)) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Sensitivity of new detection method for ultra-low frequency gravitational waves with pulsar spin-down rate statistics

    NASA Astrophysics Data System (ADS)

    Yonemaru, Naoyuki; Kumamoto, Hiroki; Takahashi, Keitaro; Kuroyanagi, Sachiko

    2018-04-01

    A new detection method for ultra-low frequency gravitational waves (GWs) with a frequency much lower than the observational range of pulsar timing arrays (PTAs) was suggested in Yonemaru et al. (2016). In the PTA analysis, ultra-low frequency GWs (≲ 10-10 Hz) which evolve just linearly during the observation time span are absorbed by the pulsar spin-down rates since both have the same effect on the pulse arrival time. Therefore, such GWs cannot be detected by the conventional method of PTAs. However, the bias on the observed spin-down rates depends on relative direction of a pulsar and GW source and shows a quadrupole pattern in the sky. Thus, if we divide the pulsars according to the position in the sky and see the difference in the statistics of the spin-down rates, ultra-low frequency GWs from a single source can be detected. In this paper, we evaluate the potential of this method by Monte-Carlo simulations and estimate the sensitivity, considering only the "Earth term" while the "pulsar term" acts like random noise for GW frequencies 10-13 - 10-10 Hz. We find that with 3,000 milli-second pulsars, which are expected to be discovered by a future survey with the Square Kilometre Array, GWs with the derivative of amplitude of about 3 × 10^{-19} {s}^{-1} can in principle be detected. Implications for possible supermassive binary black holes in Sgr* and M87 are also given.

  4. Determination of acrylamide in drinking water by large-volume direct injection and ion-exclusion chromatography-mass spectrometry.

    PubMed

    Cavalli, S; Polesello, S; Saccani, G

    2004-06-11

    Acrylamide, a known neurotoxin and putative human carcinogen, has been included among the substances to be monitored in drinking water according to the European Union Directive 98/83 on potable water. This paper reports a new method based on the combination of ion-exclusion chromatographic separation and MS detection. Samples of drinking water have been directly injected in the microbore ICE-AS1 column and detected in the selected-ion monitoring mode by a single quadrupole system with electrospray ionization. Chromatographic conditions, such as eluent composition and flow rate, have been optimized by a central composite design experiment. Statistical analysis of data showed that the amount of acetonitrile fraction in the eluent mixture, composed by acetonitrile and formic acid solution, is the variable that most influences retention of the acrylamide peak. After optimization of MS detection parameters, this method has been validated for spiked drinking water samples. The effect of large-volume injection (up to 500 microl) has been also explored. Linearity was evaluated from 0.5 to 5 microg l(-1). Repeatability, expressed as R.S.D., was 16 and 12% at 0.5 and 1 microg l(-1) respectively. The limit of detection was 0.20 ppb with 500 microl injection volume.

  5. Fast detection of atrazine in corn using thermometric biosensors.

    PubMed

    Qie, Zhiwei; Ning, Baoan; Liu, Ming; Bai, Jialei; Peng, Yuan; Song, Nan; Lv, Zhiqiang; Wang, Ying; Sun, Siming; Su, Xuan; Zhang, Yihong; Gao, Zhixian

    2013-09-07

    Fast detection is important in screening large-scale samples. This study establishes a direct competitive ELISA method (dcTELISA) based on an enzyme thermistor for fast atrazine (ATZ) detection. ATZ competes with β-lactamase-labeled ATZ (ATZ-E) for the binding sites on anti-ATZ monoclonal antibody (mAb). The mAb are covalently bound to Controlled Pore Glass (CPG) in an immunoreactor to form immunocomplexes with ATZ and ATZ-E. Several parameters of biosensor performance were optimized, such as the ATZ-E concentration, concentration and nature of the substrate, flow rate, and effect of temperature on the sensor response. After optimization, the assay time for a single sample was 12 min. The work process and result were compared with those of high-performance liquid chromatography (HPLC). The detection results exhibited a recovery rate of 88% to 107% in ATZ-spiked fresh cut corn stalks and silage samples. The results obtained via dcTELISA had good correlation with that of HPLC, and the biosensor response was reproducible and stable even when used continuously for over 4 months. All these properties suggested that the fast detection method, dcTELISA, may be used to detect pesticide residue in large-scale samples.

  6. Effectiveness of medicines authentication technology to detect counterfeit, recalled and expired medicines: a two-stage quantitative secondary care study.

    PubMed

    Naughton, Bernard; Roberts, Lindsey; Dopson, Sue; Chapman, Stephen; Brindley, David

    2016-12-09

    To identify the authentication and detection rate of serialised medicines using medicines authentication technology. 4192 serialised medicines were entered into a hospital dispensary over two separate 8-week stages in 2015. Medicines were authenticated using secure external database cross-checking, triggered by the scanning of a two-dimensional data matrix with a unit specific 12-digit serial code. 4% of medicines included were preprogrammed with a message to identify the product as either expired, pack recalled, product recalled or counterfeit. A site within a large UK National Health Service teaching hospital trust. Accredited checking staff, pharmacists and dispensers in a pharmacy department. Authentication and detection rate of counterfeit expired and recalled medicines. The operational detection rate of counterfeit, recalled and expired medicines scanned as a combined group was 81.4% (stage 1 (S1)) and 87% (stage 2 (S2)). The technology's technical detection rate (TDR) was 100%; however, not all medicines were scanned and of those that were scanned not all that generated a warning message were quarantined. Owing to an operational authentication rate (OAR) of 66.3% (over both stages), only 31.8% of counterfeit medicines, 58% of recalled drugs and 64% of expired medicines were detected as a proportion of those entered into the study. Response times (RTs) of 152 ms (S1) and 165 ms (S2) were recorded, meeting the falsified medicines directive-mandated 300 ms limit. TDRs and RTs were not a limiting factor in this study. The suboptimal OAR poses significant quality and safety issues with this detection approach. Authentication at the checking stage, however, demonstrated higher OARs. There is a need for further qualitative research to establish the reasons for less than absolute authentication and detection rates in the hospital environment to improve this technology in preparation for the incumbent European Union regulative deadline. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Fundus fluorescence Angiography in diagnosing diabetic retinopathy.

    PubMed

    Wang, Shuhui; Zuo, Yuqin; Wang, Ning; Tong, Bin

    2017-01-01

    To investigate the manifestation characteristics of fundus fluorescence angiography (FFA) and its values in diagnosing diabetic retinopathy through comparing direct ophthalmoscopy. Two hundred fifty patients (500 eyes) who were suspected as diabetic retinopathy and admitted to the hospital between February 2015 and December 2016 were selected. They underwent direct ophthalmoscopy and FFA. The manifestation characteristics of FFA in the diagnosis of diabetic retinopathy were summarized. The two examination methods were compared. In the diagnosis with direct ophthalmoscopy, 375 eyes out of 500 eyes were diagnosed as diabetic retinopathy (75%); there were 74 eyes at stage I, 88 eyes at stage II, 92 eyes at stage III, 83 eyes of stage IV, 28 eyes of stage V and 10 eyes of stage VI. In the diagnosis with FFA, 465 eyes out of 500 eyes were diagnosed as diabetic retinopathy (93%); there were 94 eyes at stage I, 110 eyes at stage II, 112 at stage III, 92 eyes at stage IV, 41 eyes at stage V and 16 eyes at stage VI. The detection rate of diabetic retinopathy using FFA was significantly higher than that using direct ophthalmoscopy (P<0.05). FFA found that 316 eyes had non-proliferative retinopathy (67.96%), 75 eyes had pre-proliferative lesions (16.13%), 149 eyes had proliferative lesions (32.04%), 135 eyes had diabetic maculopathy (29.03%) and 31 eyes had diabetic optic disc lesions (6.67%). The detection rate of diabetic retinopathy using FFA is higher than that using direct ophthalmoscopy. FFA could accurately determine clinical stage. Therefore, it is an important approach in treatment efficacy evaluation and treatment guidance, suggesting a significant application value.

  8. Statistical study of muons counts rates in differents directions, observed at the Brazilian Southern Space Observatory

    NASA Astrophysics Data System (ADS)

    Grams, Guilherme; Schuch, Nelson Jorge; Braga, Carlos Roberto; Purushottam Kane, Rajaram; Echer, Ezequiel; Ronan Coelho Stekel, Tardelli

    Cosmic ray are charged particles, at the most time protons, that reach the earth's magne-tosphere from interplanetary space with velocities greater than the solar wind. When these impinge the atmosphere, they interact with atmosphere constituents and decay into sub-particles forming an atmospheric shower. The muons are the sub-particles which normally maintain the originated direction of the primary cosmic ray. A multi-directional muon detec-tor (MMD) was installed in 2001 and upgraded in 2005, through an international cooperation between Brazil, Japan and USA, and operated since then at the Southern Space Observatory -SSO/CRS/CCR/INPE -MCT, (29,4° S, 53,8° W, 480m a.s.l.), São Martinho da Serra, RS, a Brazil. The main objetive of this work is to present a statistical analysis of the intensity of muons, with energy between 50 and 170 GeV, in differents directions, measured by the SSO's multi-directional muon detector. The analysis was performed with data from 2006 and 2007 collected by the SSO's MMD. The MMD consists of two layers of 4x7 detectors with a total observation area of 28 m2 . The counting of muons in each directional channel is made by a coincidence of pulses pair, one from a detector in the upper layer and the other from a detector in the lower layer. The SSO's MMD is equipped with 119 directional channels for muon count rate measurement and is capable of detecting muons incident with zenithal angle between 0° and 75,53° . A statistical analysis was made with the MMD muon count rate for all the di-rectional channels. The average and the standard deviation of the muon count rate in each directional component were calculated. The results show lower cont rate for the channels with larger zenith, and higher cont rate with smaller zenith, as expected from the production and propagation of muons in the atmosphere. It is also possible to identify the Stormer cone. The SSO's MMD is also a detector component of the Global Muon Detector Network (GMDN), which has been developed in an international collaboration lead by Shinshu University, Japan.

  9. Real-Time Detection of Sporadic Meteors in the Intensified TV Imaging Systems.

    PubMed

    Vítek, Stanislav; Nasyrova, Maria

    2017-12-29

    The automatic observation of the night sky through wide-angle video systems with the aim of detecting meteor and fireballs is currently among routine astronomical observations. The observation is usually done in multi-station or network mode, so it is possible to estimate the direction and the speed of the body flight. The high velocity of the meteorite flying through the atmosphere determines the important features of the camera systems, namely the high frame rate. Thanks to high frame rates, such imaging systems produce a large amount of data, of which only a small fragment has scientific potential. This paper focuses on methods for the real-time detection of fast moving objects in the video sequences recorded by intensified TV systems with frame rates of about 60 frames per second. The goal of our effort is to remove all unnecessary data during the daytime and make free hard-drive capacity for the next observation. The processing of data from the MAIA (Meteor Automatic Imager and Analyzer) system is demonstrated in the paper.

  10. Real-Time Detection of Sporadic Meteors in the Intensified TV Imaging Systems

    PubMed Central

    2017-01-01

    The automatic observation of the night sky through wide-angle video systems with the aim of detecting meteor and fireballs is currently among routine astronomical observations. The observation is usually done in multi-station or network mode, so it is possible to estimate the direction and the speed of the body flight. The high velocity of the meteorite flying through the atmosphere determines the important features of the camera systems, namely the high frame rate. Thanks to high frame rates, such imaging systems produce a large amount of data, of which only a small fragment has scientific potential. This paper focuses on methods for the real-time detection of fast moving objects in the video sequences recorded by intensified TV systems with frame rates of about 60 frames per second. The goal of our effort is to remove all unnecessary data during the daytime and make free hard-drive capacity for the next observation. The processing of data from the MAIA (Meteor Automatic Imager and Analyzer) system is demonstrated in the paper. PMID:29286294

  11. Concomitant ALK translocation and EGFR mutation in lung cancer: a comparison of direct sequencing and sensitive assays and the impact on responsiveness to tyrosine kinase inhibitor.

    PubMed

    Won, J K; Keam, B; Koh, J; Cho, H J; Jeon, Y K; Kim, T M; Lee, S H; Lee, D S; Kim, D W; Chung, D H

    2015-02-01

    Epidermal growth factor receptor (EGFR) mutation and anaplastic lymphoma kinase (ALK) translocation are considered mutually exclusive in nonsmall-cell lung cancer (NSCLC). However, sporadic cases having concomitant EGFR and ALK alterations have been reported. The present study aimed to assess the prevalence of NSCLCs with concomitant EGFR and ALK alterations using mutation detection methods with different sensitivity and to propose an effective diagnostic and therapeutic strategy. A total of 1458 cases of lung cancer were screened for EGFR and ALK alterations by direct sequencing and flourescence in situ hybridization (FISH), respectively. For the 91 patients identified as having an ALK translocation, peptide nucleic acid (PNA)-clamping real-time PCR, targeted next-generation sequencing (NGS), and mutant-enriched NGS assays were carried out to detect EGFR mutation. EGFR mutations and ALK translocations were observed in 42.4% (612/1445) and 6.3% (91/1445) of NSCLCs by direct sequencing and FISH, respectively. Concomitant EGFR and ALK alterations were detected in four cases, which accounted for 4.4% (4/91) of ALK-translocated NSCLCs. Additional analyses for EGFR using PNA real-time PCR and ultra-deep sequencing by NGS, mutant-enriched NGS increased the detection rate of concomitant EGFR and ALK alterations to 8.8% (8/91), 12.1% (11/91), and 15.4% (14/91) of ALK-translocated NSCLCs, respectively. Of the 14 patients, 3 who were treated with gefitinib showed poor response to gefitinib with stable disease in one and progressive disease in two patients. However, eight patients who received ALK inhibitor (crizotinib or ceritinib) showed good response, with response rate of 87.5% (7/8 with partial response) and durable progression-free survival. A portion of NSCLC patients have concomitant EGFR and ALK alterations and the frequency of co-alteration detection increases when sensitive detection methods for EGFR mutation are applied. ALK inhibitors appear to be effective for patients with co-alterations. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  12. Chaos-on-a-chip secures data transmission in optical fiber links.

    PubMed

    Argyris, Apostolos; Grivas, Evangellos; Hamacher, Michael; Bogris, Adonis; Syvridis, Dimitris

    2010-03-01

    Security in information exchange plays a central role in the deployment of modern communication systems. Besides algorithms, chaos is exploited as a real-time high-speed data encryption technique which enhances the security at the hardware level of optical networks. In this work, compact, fully controllable and stably operating monolithic photonic integrated circuits (PICs) that generate broadband chaotic optical signals are incorporated in chaos-encoded optical transmission systems. Data sequences with rates up to 2.5 Gb/s with small amplitudes are completely encrypted within these chaotic carriers. Only authorized counterparts, supplied with identical chaos generating PICs that are able to synchronize and reproduce the same carriers, can benefit from data exchange with bit-rates up to 2.5Gb/s with error rates below 10(-12). Eavesdroppers with access to the communication link experience a 0.5 probability to detect correctly each bit by direct signal detection, while eavesdroppers supplied with even slightly unmatched hardware receivers are restricted to data extraction error rates well above 10(-3).

  13. Multisensor fusion for the detection of mines and minelike targets

    NASA Astrophysics Data System (ADS)

    Hanshaw, Terilee

    1995-06-01

    The US Army's Communications and Electronics Command through the auspices of its Night Vision and Electronics Sensors Directorate (CECOM-NVESD) is actively applying multisensor techniques to the detection of mine targets. This multisensor research results from the 'detection activity' with its broad range of operational conditions and targets. Multisensor operation justifies significant attention by yielding high target detection and low false alarm statistics. Furthermore, recent advances in sensor and computing technologies make its practical application realistic and affordable. The mine detection field-of-endeavor has since its WWI baptismal investigated the known spectra for applicable mine observation phenomena. Countless sensors, algorithms, processors, networks, and other techniques have been investigated to determine candidacy for mine detection. CECOM-NVESD efforts have addressed a wide range of sensors spanning the spectrum from gravity field perturbations, magentic field disturbances, seismic sounding, electromagnetic fields, earth penetrating radar imagery, and infrared/visible/ultraviolet surface imaging technologies. Supplementary analysis has considered sensor candidate applicability by testing under field conditions (versus laboratory), in determination of fieldability. As these field conditions directly effect the probability of detection and false alarms, sensor employment and design must be considered. Consequently, as a given sensor's performance is influenced directly by the operational conditions, tradeoffs are necessary. At present, mass produced and fielded mine detection techniques are limited to those incorporating a single sensor/processor methodology such as, pulse induction and megnetometry, as found in hand held detectors. The most sensitive fielded systems can detect minute metal components in small mine targets but result in very high false alarm rates reducing velocity in operation environments. Furthermore, the actual speed of advance for the entire mission (convoy, movement to engagement, etc.) is determined by the level of difficulty presented in clearance or avoidance activities required in response to the potential 'targets' marked throughout a detection activity. Therefore the application of fielded hand held systems to convoy operations in clearly impractical. CECOM-NVESD efforts are presently seeking to overcome these operational limitations by substantially increasing speed of detection while reducing the false alarm rate through the application of multisensor techniques. The CECOM-NVESD application of multisensor techniques through integration/fusion methods will be defined in this paper.

  14. Multipath interference test method for distributed amplifiers

    NASA Astrophysics Data System (ADS)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  15. Aircraft Detection in High-Resolution SAR Images Based on a Gradient Textural Saliency Map.

    PubMed

    Tan, Yihua; Li, Qingyun; Li, Yansheng; Tian, Jinwen

    2015-09-11

    This paper proposes a new automatic and adaptive aircraft target detection algorithm in high-resolution synthetic aperture radar (SAR) images of airport. The proposed method is based on gradient textural saliency map under the contextual cues of apron area. Firstly, the candidate regions with the possible existence of airport are detected from the apron area. Secondly, directional local gradient distribution detector is used to obtain a gradient textural saliency map in the favor of the candidate regions. In addition, the final targets will be detected by segmenting the saliency map using CFAR-type algorithm. The real high-resolution airborne SAR image data is used to verify the proposed algorithm. The results demonstrate that this algorithm can detect aircraft targets quickly and accurately, and decrease the false alarm rate.

  16. Noise considerations for remote detection of life signs with microwave Doppler radar.

    PubMed

    Nguyen, Dung; Yamada, Shuhei; Park, Byung-Kwon; Lubecke, Victor; Boric-Lubecke, Olga; Host-Madsen, Anders

    2007-01-01

    This paper describes and quantifies three main sources of baseband noise affecting physiological signals in a direct conversion microwave Doppler radar for life signs detection. They are thermal noise, residual phase noise, and Flicker noise. In order to increase the SNR of physiological signals at baseband, the noise floor, in which the Flicker noise is the most dominant factor, needs to be minimized. This paper shows that with the consideration of the noise factor in our Doppler radar, Flicker noise canceling techniques may drastically reduce the power requirement for heart rate signal detection by as much as a factor of 100.

  17. Effects of the Sagittarius dwarf tidal stream on dark matter detectors.

    PubMed

    Freese, Katherine; Gondolo, Paolo; Newberg, Heidi Jo; Lewis, Matthew

    2004-03-19

    The Sagittarius dwarf tidal stream may be showering dark matter onto the solar neighborhood, which can change the results and interpretation of direct detection searches for weakly interacting massive particles (WIMPs). Stars in the stream may already have been detected in the solar neighborhood, and the dark matter in the stream is (0.3-25)% of the local density. Experiments should see an annually modulated steplike feature in the energy recoil spectrum that would be a smoking gun for WIMP detection. The total count rate in detectors is not a cosine curve in time and peaks at a different time of year than the standard case.

  18. Power corrections to the universal heavy WIMP-nucleon cross section

    NASA Astrophysics Data System (ADS)

    Chen, Chien-Yi; Hill, Richard J.; Solon, Mikhail P.; Wijangco, Alexander M.

    2018-06-01

    WIMP-nucleon scattering is analyzed at order 1 / M in Heavy WIMP Effective Theory. The 1 / M power corrections, where M ≫mW is the WIMP mass, distinguish between different underlying UV models with the same universal limit and their impact on direct detection rates can be enhanced relative to naive expectations due to generic amplitude-level cancellations at leading order. The necessary one- and two-loop matching calculations onto the low-energy effective theory for WIMP interactions with Standard Model quarks and gluons are performed for the case of an electroweak SU(2) triplet WIMP, considering both the cases of elementary fermions and composite scalars. The low-velocity WIMP-nucleon scattering cross section is evaluated and compared with current experimental limits and projected future sensitivities. Our results provide the most robust prediction for electroweak triplet Majorana fermion dark matter direct detection rates; for this case, a cancellation between two sources of power corrections yields a small total 1 / M correction, and a total cross section close to the universal limit for M ≳ few × 100GeV. For the SU(2) composite scalar, the 1 / M corrections introduce dependence on underlying strong dynamics. Using a leading chiral logarithm evaluation, the total 1 / M correction has a larger magnitude and uncertainty than in the fermionic case, with a sign that further suppresses the total cross section. These examples provide definite targets for future direct detection experiments and motivate large scale detectors capable of probing to the neutrino floor in the TeV mass regime.

  19. Behavioral analyses of wind-evoked escape of the cricket, Gryllodes sigillatus.

    PubMed

    Kanou, Masamichi; Konishi, Atsuko; Suenaga, Rie

    2006-04-01

    The wind-evoked escape behavior of the cricket Gryllodes sigillatus was investigated using an air puff stimulus. A high velocity air puff elicited the escape behavior in many crickets. The crickets tended to escape away from the stimulus source, but the direction was not accurately oriented 180 degrees from the stimulus. After bilateral cercal ablation, only a few crickets showed wind-evoked escape behavior, and their response rates did not increase even 19 days after ablation. Therefore, information on air motion detected by cercal filiform hairs is essential for triggering wind-evoked behavior. After unilateral cercal ablation, the 81.3% response rate of intact crickets decreased to 16.5%, that is, it decreased to almost 20% that of intact crickets. One week after unilateral cercal ablation, the response rate recovered to more than 60% that of intact crickets. However, the accuracy rate of the escape direction of G. sigillatus showed no change even immediately after the unilateral cercal ablation. Therefore, both cerci are not necessarily required to determine the escape direction. The behavioral characteristics of wind-evoked escape of G. sigillatus are compared with those of another species of cricket, Gryllus bimaculatus. The two species of cricket employ different strategies for wind-evoked escape.

  20. Toward structural dynamics: protein motions viewed by chemical shift modulations and direct detection of C'N multiple-quantum relaxation.

    PubMed

    Mori, Mirko; Kateb, Fatiha; Bodenhausen, Geoffrey; Piccioli, Mario; Abergel, Daniel

    2010-03-17

    Multiple quantum relaxation in proteins reveals unexpected relationships between correlated or anti-correlated conformational backbone dynamics in alpha-helices or beta-sheets. The contributions of conformational exchange to the relaxation rates of C'N coherences (i.e., double- and zero-quantum coherences involving backbone carbonyl (13)C' and neighboring amide (15)N nuclei) depend on the kinetics of slow exchange processes, as well as on the populations of the conformations and chemical shift differences of (13)C' and (15)N nuclei. The relaxation rates of C'N coherences, which reflect concerted fluctuations due to slow chemical shift modulations (CSMs), were determined by direct (13)C detection in diamagnetic and paramagnetic proteins. In well-folded proteins such as lanthanide-substituted calbindin (CaLnCb), copper,zinc superoxide dismutase (Cu,Zn SOD), and matrix metalloproteinase (MMP12), slow conformational exchange occurs along the entire backbone. Our observations demonstrate that relaxation rates of C'N coherences arising from slow backbone dynamics have positive signs (characteristic of correlated fluctuations) in beta-sheets and negative signs (characteristic of anti-correlated fluctuations) in alpha-helices. This extends the prospects of structure-dynamics relationships to slow time scales that are relevant for protein function and enzymatic activity.

  1. An Evaluation of Psychophysical Models of Auditory Change Perception

    PubMed Central

    Micheyl, Christophe; Kaernbach, Christian; Demany, Laurent

    2009-01-01

    In many psychophysical experiments, the participant's task is to detect small changes along a given stimulus dimension, or to identify the direction (e.g., upward vs. downward) of such changes. The results of these experiments are traditionally analyzed using a constant-variance Gaussian (CVG) model or a high-threshold (HT) model. Here, the authors demonstrate that for changes along three basic sound dimensions (frequency, intensity, and amplitude-modulation rate), such models cannot account for the observed relationship between detection thresholds and direction-identification thresholds. It is shown that two alternative models can account for this relationship. One of them is based on the idea of sensory “quanta”; the other assumes that small changes are detected on the basis of Poisson processes with low means. The predictions of these two models are then compared against receiver operating characteristics (ROCs) for the detection of changes in sound intensity. It is concluded that human listeners' perception of small and unidimensional acoustic changes is better described by a discrete-state Poisson model than by the more commonly used CVG model or by the less favored HT and quantum models. PMID:18954215

  2. Word timing recovery in direct detection optical PPM communication systems with avalanche photodiodes using a phase lock loop

    NASA Technical Reports Server (NTRS)

    Sun, Xiaoli; Davidson, Frederic M.

    1990-01-01

    A technique for word timing recovery in a direct-detection optical PPM communication system is described. It tracks on back-to-back pulse pairs in the received random PPM data sequences with the use of a phase locked loop. The experimental system consisted of an 833-nm AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector, and it used Q = 4 PPM signaling at source data rate 25 Mb/s. The mathematical model developed to describe system performance is shown to be in good agreement with the experimental measurements. Use of this recovered PPM word clock with a slot clock recovery system caused no measurable penalty in receiver sensitivity. The completely self-synchronized receiver was capable of acquiring and maintaining both slot and word synchronizations for input optical signal levels as low as 20 average detected photons per information bit. The receiver achieved a bit error probability of 10 to the -6th at less than 60 average detected photons per information bit.

  3. Modulation and coding for throughput-efficient optical free-space links

    NASA Technical Reports Server (NTRS)

    Georghiades, Costas N.

    1993-01-01

    Optical direct-detection systems are currently being considered for some high-speed inter-satellite links, where data-rates of a few hundred megabits per second are evisioned under power and pulsewidth constraints. In this paper we investigate the capacity, cutoff-rate and error-probability performance of uncoded and trellis-coded systems for various modulation schemes and under various throughput and power constraints. Modulation schemes considered are on-off keying (OOK), pulse-position modulation (PPM), overlapping PPM (OPPM) and multi-pulse (combinatorial) PPM (MPPM).

  4. Real-time association rate constant measurement using combination tapered fiber-optic biosensor (CTFOB) dip-probes

    NASA Astrophysics Data System (ADS)

    Simmonds, Boris; Wang, Chun-Wei; Kapoor, Rakesh

    2010-02-01

    This document reports a novel method of measuring association rate constant (ka) for antibody-antigen interaction using evanescent wave-based combination tapered fiber-optic biosensor (CTFOB) dip-probes. The method was demonstrated by measuring association rate constant for bovine serum albumin (BSA) and anti-BSA antibody interaction. "Direct method" was used for detection; goat anti-BSA "capture" antibodies were immobilized on the probe surfaces while the antigen (BSA) was directly labeled with Alexa 488 dye. The probes were subsequently submerged in 3nM Labeled BSA in egg albumin (1 mg/ml). The fluorescence signal recorded was proportional to BSA anti-BSA conjugates and continuous signal was acquired suing a fiber optic spectrometer (Ocean Optics, Inc.). A 476 nm diode laser was use as an excitation source. Association constant was estimated from a plot of signal as a function of time. Measured association rate constant ka for the binding of BSA with anti-BSA at room temperature is (8.33 +/- 0.01) x 104 M-1s-1.

  5. [Investigation of gastric cancers detected at a medical check-up center].

    PubMed

    Kura, T; Kumaki, T; Matsuhisa, T; Tanaka, S

    1996-06-01

    Most of the gastric cancers investigated in this study were detected during mass screening at a Medical Check-up Center. The research period was 5 years, from 1990 to 1994. The total number of patients undergoing initial gastric examinations was 300,658. Four point eight percent of these needed detailed examinations, and 77.2% actually underwent detailed examinations. Over the 5 years, the number of gastric cancers detected was 253. The rate of detection of these cancers was almost unchanged every year, with the average rate of change being 0.11%. The rate of detected gastric cancers was investigated according to age and sex. No cancers were found below age 29, and the rate gradually rose over age 30. Over age 50, the rate in males was twice that in females. The rate of early gastric cancers was 66.4% of all reported cancers. As regards location of 253 cases, 16.5% were in the C-area, 45.8% in the M-area, 36.2% in the A-area; 19.2% were in the greater curvature, 33.9% were in the lesser curvature, 17.3% in the anterior wall, and 26.1% in the posterior wall. The sizes of the lesions were as follows: 11.5% were below 1.0 cm, 29.6% were from 1.1 cm to 2.0 cm, 46.6% were from 2.1 cm to 5.0 cm, and 12.3% were over 5.1 cm. It was considered that indirect X-rays were slightly inferior to direct X-rays in detecting early gastric cancer. The X-ray positionings in which cancers were detected were: 75.7% by supine double contrast and 48.6% by compression in 144 cases of early cancer. On the other hand, the rate were 75.6% by supine double contrast, and 51.2% by compression in 82 cases of advanced cancer. A similar tendency was found in one-shot X-ray positioning which revealed cancers. The rate of gastric cancer notdetected by X-ray pictures was 5.9% of the 253 cases. The size of the cancers notdetected by X-ray was within 2.0 cm in all cases. 58.7% of the 155 early cancer patients and 48.2% of the 83 advanced cancer patients had examinations the previous year. Therefore, it is clear that some cases of advanced cancer were not detected in the mass gastric screenings. Endoscopically, 7 cases of gastric cancer were diagnosed correctly by means of repeated biopsies which were needed 3 or 4 times over 3 to 18 months owing to pseudonegative findings on the first bioptic examination. Consequently, it is necessary to make naked eye diagnosis by endoscopic examination. Six cases of death from gastric cancer were certified within one year after normal diagnosis during the mass screening. Three cases were Borr. 4, 2 cases Borr. 3, and 1 case was Borr 2. A retrospective investigation of X-ray pictures showed that it would have been difficult to identify the lesions in these cases. The above results show that the accuracy of examinations and diagnosis must be raised in mass gastric screenings, but it is doubtful whether relying on the present methods of screening will lead to a marked improvement. For the purpose of increasing the effectiveness of mass gastric screening, we would emphasize the necessity of the following new tests; serum pepsinogen measurement, reinvestigation of patient's ages, shortening the intervals between examinations in high risk groups, using direct X-rays rather than indirect X-rays, and intermitted endoscopic examinations.

  6. The effects of flow on schooling Devario aequipinnatus: school structure, startle response and information transmission

    PubMed Central

    Chicoli, A.; Butail, S.; Lun, Y.; Bak-Coleman, J.; Coombs, S.; Paley, D.A.

    2014-01-01

    To assess how flow affects school structure and threat detection, startle response rates of solitary and small groups of giant danio Devario aequipinnatus were compared to visual looming stimuli in flow and no-flow conditions. The instantaneous position and heading of each D. aequipinnatus were extracted from high-speed videos. Behavioural results indicate that (1) school structure is altered in flow such that D. aequipinnatus orient upstream while spanning out in a crosswise direction, (2) the probability of at least one D. aequipinnatus detecting the visual looming stimulus is higher in flow than no flow for both solitary D. aequipinnatus and groups of eight D. aequipinnatus, however, (3) the probability of three or more individuals responding is higher in no flow than flow. Taken together, these results indicate a higher probability of stimulus detection in flow but a higher probability of internal transmission of information in no flow. Finally, results were well predicted by a computational model of collective fright response that included the probability of direct detection (based on signal detection theory) and indirect detection (i.e. via interactions between group members) of threatening stimuli. This model provides a new theoretical framework for analysing the collective transfer of information among groups of fishes and other organisms. PMID:24773538

  7. A Simulation Study of Acoustic-Assisted Tracking of Whales for Mark-Recapture Surveys

    PubMed Central

    Peel, David; Miller, Brian S.; Kelly, Natalie; Dawson, Steve; Slooten, Elisabeth; Double, Michael C.

    2014-01-01

    Collecting enough data to obtain reasonable abundance estimates of whales is often difficult, particularly when studying rare species. Passive acoustics can be used to detect whale sounds and are increasingly used to estimate whale abundance. Much of the existing effort centres on the use of acoustics to estimate abundance directly, e.g. analysing detections in a distance sampling framework. Here, we focus on acoustics as a tool incorporated within mark-recapture surveys. In this context, acoustic tools are used to detect and track whales, which are then photographed or biopsied to provide data for mark-recapture analyses. The purpose of incorporating acoustics is to increase the encounter rate beyond using visual searching only. While this general approach is not new, its utility is rarely quantified. This paper predicts the “acoustically-assisted” encounter rate using a discrete-time individual-based simulation of whales and survey vessel. We validate the simulation framework using existing data from studies of sperm whales. We then use the framework to predict potential encounter rates in a study of Antarctic blue whales. We also investigate the effects of a number of the key parameters on encounter rate. Mean encounter rates from the simulation of sperm whales matched well with empirical data. Variance of encounter rate, however, was underestimated. The simulation of Antarctic blue whales found that passive acoustics should provide a 1.7–3.0 fold increase in encounter rate over visual-only methods. Encounter rate was most sensitive to acoustic detection range, followed by vocalisation rate. During survey planning and design, some indication of the relationship between expected sample size and effort is paramount; this simulation framework can be used to predict encounter rates and establish this relationship. For a case in point, the simulation framework indicates unequivocally that real-time acoustic tracking should be considered for quantifying the abundance of Antarctic blue whales via mark-recapture methods. PMID:24827919

  8. A simulation study of acoustic-assisted tracking of whales for mark-recapture surveys.

    PubMed

    Peel, David; Miller, Brian S; Kelly, Natalie; Dawson, Steve; Slooten, Elisabeth; Double, Michael C

    2014-01-01

    Collecting enough data to obtain reasonable abundance estimates of whales is often difficult, particularly when studying rare species. Passive acoustics can be used to detect whale sounds and are increasingly used to estimate whale abundance. Much of the existing effort centres on the use of acoustics to estimate abundance directly, e.g. analysing detections in a distance sampling framework. Here, we focus on acoustics as a tool incorporated within mark-recapture surveys. In this context, acoustic tools are used to detect and track whales, which are then photographed or biopsied to provide data for mark-recapture analyses. The purpose of incorporating acoustics is to increase the encounter rate beyond using visual searching only. While this general approach is not new, its utility is rarely quantified. This paper predicts the "acoustically-assisted" encounter rate using a discrete-time individual-based simulation of whales and survey vessel. We validate the simulation framework using existing data from studies of sperm whales. We then use the framework to predict potential encounter rates in a study of Antarctic blue whales. We also investigate the effects of a number of the key parameters on encounter rate. Mean encounter rates from the simulation of sperm whales matched well with empirical data. Variance of encounter rate, however, was underestimated. The simulation of Antarctic blue whales found that passive acoustics should provide a 1.7-3.0 fold increase in encounter rate over visual-only methods. Encounter rate was most sensitive to acoustic detection range, followed by vocalisation rate. During survey planning and design, some indication of the relationship between expected sample size and effort is paramount; this simulation framework can be used to predict encounter rates and establish this relationship. For a case in point, the simulation framework indicates unequivocally that real-time acoustic tracking should be considered for quantifying the abundance of Antarctic blue whales via mark-recapture methods.

  9. An Automated Directed Spectral Search Methodology for Small Target Detection

    NASA Astrophysics Data System (ADS)

    Grossman, Stanley I.

    Much of the current efforts in remote sensing tackle macro-level problems such as determining the extent of wheat in a field, the general health of vegetation or the extent of mineral deposits in an area. However, for many of the remaining remote sensing challenges being studied currently, such as border protection, drug smuggling, treaty verification, and the war on terror, most targets are very small in nature - a vehicle or even a person. While in typical macro-level problems the objective vegetation is in the scene, for small target detection problems it is not usually known if the desired small target even exists in the scene, never mind finding it in abundance. The ability to find specific small targets, such as vehicles, typifies this problem. Complicating the analyst's life, the growing number of available sensors is generating mountains of imagery outstripping the analysts' ability to visually peruse them. This work presents the important factors influencing spectral exploitation using multispectral data and suggests a different approach to small target detection. The methodology of directed search is presented, including the use of scene-modeled spectral libraries, various search algorithms, and traditional statistical and ROC curve analysis. The work suggests a new metric to calibrate analysis labeled the analytic sweet spot as well as an estimation method for identifying the sweet spot threshold for an image. It also suggests a new visualization aid for highlighting the target in its entirety called nearest neighbor inflation (NNI). It brings these all together to propose that these additions to the target detection arena allow for the construction of a fully automated target detection scheme. This dissertation next details experiments to support the hypothesis that the optimum detection threshold is the analytic sweet spot and that the estimation method adequately predicts it. Experimental results and analysis are presented for the proposed directed search techniques of spectral image based small target detection. It offers evidence of the functionality of the NNI visualization and also provides evidence that the increased spectral dimensionality of the 8-band Worldview-2 datasets provides noteworthy improvement in results over traditional 4-band multispectral datasets. The final experiment presents the results from a prototype fully automated target detection scheme in support of the overarching premise. This work establishes the analytic sweet spot as the optimum threshold defined as the point where error detection rate curves -- false detections vs. missing detections -- cross. At this point the errors are minimized while the detection rate is maximized. It then demonstrates that taking the first moment statistic of the histogram of calculated target detection values from a detection search with test threshold set arbitrarily high will estimate the analytic sweet spot for that image. It also demonstrates that directed search techniques -- when utilized with appropriate scene-specific modeled signatures and atmospheric compensations -- perform at least as well as in-scene search techniques 88% of the time and grossly under-performing only 11% of the time; the in-scene only performs as well or better 50% of the time. It further demonstrates the clear advantage increased multispectral dimensionality brings to detection searches improving performance in 50% of the cases while performing at least as well 72% of the time. Lastly, it presents evidence that a fully automated prototype performs as anticipated laying the groundwork for further research into fully automated processes for small target detection.

  10. Flowing water affects fish fast-starts: escape performance of the Hawaiian stream goby, Sicyopterus stimpsoni.

    PubMed

    Diamond, Kelly M; Schoenfuss, Heiko L; Walker, Jeffrey A; Blob, Richard W

    2016-10-01

    Experimental measurements of escape performance in fishes have typically been conducted in still water; however, many fishes inhabit environments with flow that could impact escape behavior. We examined the influences of flow and predator attack direction on the escape behavior of fish, using juveniles of the amphidromous Hawaiian goby Sicyopterus stimpsoni In nature, these fish must escape ambush predation while moving through streams with high-velocity flow. We measured the escape performance of juvenile gobies while exposing them to a range of water velocities encountered in natural streams and stimulating fish from three different directions. Frequency of response across treatments indicated strong effects of flow conditions and attack direction. Juvenile S. stimpsoni had uniformly high response rates for attacks from a caudal direction (opposite flow); however, response rates for attacks from a cranial direction (matching flow) decreased dramatically as flow speed increased. Mechanical stimuli produced by predators attacking in the same direction as flow might be masked by the flow environment, impairing the ability of prey to detect attacks. Thus, the likelihood of successful escape performance in fishes can depend critically on environmental context. © 2016. Published by The Company of Biologists Ltd.

  11. Incidence and Mortality of Breast Cancer and their Relationship with the Human Development Index (HDI) in the World in 2012.

    PubMed

    Ghoncheh, Mahshid; Mirzaei, Maryam; Salehiniya, Hamid

    2015-01-01

    Breast cancer is the most common malignancy in women worldwide and its incidence is generally increasing. In 2012, it was the second most common cancer in the world. It is necessary to obtain information on incidence and mortality for health planning. This study aimed to investigate the relationship between the human development index (HDI), and the incidence and mortality rates of breast cancer in the world in 2012. This ecologic study concerns incidence rate and standardized mortality rates of the cancer from GLOBOCAN in 2012, and HDI and its components extracted from the global bank site. Data were analyzed using correlation tests and regression with SPSS software (version 15). Among the six regions of WHO, the highest breast cancer incidence rate (67.6) was observed in the PAHO, and the lowest incidence rate was 27.8 for SEARO. There was a direct, strong, and meaningful correlation between the standardized incidence rate and HDI (r=0.725, p≤0.001). Pearson correlation test showed that there was a significant correlation between age-specific incidence rate (ASIR) and components of the HDI (life expectancy at birth, mean years of schooling, and GNP). On the other, a non-significant relationship was observed between ASIR and HDI overall (r=0.091, p=0.241). In total, a significant relationship was not found between age-specific mortality rate (ASMR) and components of HDI. Significant positive correlations exist between ASIR and components of the HDI. Socioeconomic status is directly related to the stage of the cancer and patient's survival. With increasing the incidence rate of the cancer, mortality rate from the cancer does not necessariloy increase. This may be due to more early detection and treatment in developed that developing countries. It is necessary to increase awareness of risk factors and early detection in the latter.

  12. Assessing alternatives for directional detection of a halo of weakly interacting massive particles

    NASA Astrophysics Data System (ADS)

    Copi, Craig J.; Krauss, Lawrence M.; Simmons-Duffin, David; Stroiney, Steven R.

    2007-01-01

    The future of direct terrestrial WIMP detection lies on two fronts: new, much larger low background detectors sensitive to energy deposition, and detectors with directional sensitivity. The former can explore a large range of WIMP parameter space using well-tested technology while the latter may be necessary if one is to disentangle particle physics parameters from astrophysical halo parameters. Because directional detectors will be quite difficult to construct it is worthwhile exploring in advance generally which experimental features will yield the greatest benefits at the lowest costs. We examine the sensitivity of directional detectors with varying angular tracking resolution with and without the ability to distinguish forward versus backward recoils, and compare these to the sensitivity of a detector where the track is projected onto a two-dimensional plane. The latter detector regardless of where it is placed on the Earth, can be oriented to produce a significantly better discrimination signal than a 3D detector without this capability, and with sensitivity within a factor of 2 of a full 3D tracking detector. Required event rates to distinguish signals from backgrounds for a simple isothermal halo range from the low teens in the best case to many thousands in the worst.

  13. Performance evaluation of the HepB Typer-Entecavir kit for detection of entecavir resistance mutations in chronic hepatitis B.

    PubMed

    Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Kim, Soo-Ok; Han, Kwang-Hyub

    2013-12-01

    Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B.

  14. Camera trap placement and the potential for bias due to trails and other features

    PubMed Central

    Forrester, Tavis D.

    2017-01-01

    Camera trapping has become an increasingly widespread tool for wildlife ecologists, with large numbers of studies relying on photo capture rates or presence/absence information. It is increasingly clear that camera placement can directly impact this kind of data, yet these biases are poorly understood. We used a paired camera design to investigate the effect of small-scale habitat features on species richness estimates, and capture rate and detection probability of several mammal species in the Shenandoah Valley of Virginia, USA. Cameras were deployed at either log features or on game trails with a paired camera at a nearby random location. Overall capture rates were significantly higher at trail and log cameras compared to their paired random cameras, and some species showed capture rates as much as 9.7 times greater at feature-based cameras. We recorded more species at both log (17) and trail features (15) than at their paired control cameras (13 and 12 species, respectively), yet richness estimates were indistinguishable after 659 and 385 camera nights of survey effort, respectively. We detected significant increases (ranging from 11–33%) in detection probability for five species resulting from the presence of game trails. For six species detection probability was also influenced by the presence of a log feature. This bias was most pronounced for the three rodents investigated, where in all cases detection probability was substantially higher (24.9–38.2%) at log cameras. Our results indicate that small-scale factors, including the presence of game trails and other features, can have significant impacts on species detection when camera traps are employed. Significant biases may result if the presence and quality of these features are not documented and either incorporated into analytical procedures, or controlled for in study design. PMID:29045478

  15. Camera trap placement and the potential for bias due to trails and other features.

    PubMed

    Kolowski, Joseph M; Forrester, Tavis D

    2017-01-01

    Camera trapping has become an increasingly widespread tool for wildlife ecologists, with large numbers of studies relying on photo capture rates or presence/absence information. It is increasingly clear that camera placement can directly impact this kind of data, yet these biases are poorly understood. We used a paired camera design to investigate the effect of small-scale habitat features on species richness estimates, and capture rate and detection probability of several mammal species in the Shenandoah Valley of Virginia, USA. Cameras were deployed at either log features or on game trails with a paired camera at a nearby random location. Overall capture rates were significantly higher at trail and log cameras compared to their paired random cameras, and some species showed capture rates as much as 9.7 times greater at feature-based cameras. We recorded more species at both log (17) and trail features (15) than at their paired control cameras (13 and 12 species, respectively), yet richness estimates were indistinguishable after 659 and 385 camera nights of survey effort, respectively. We detected significant increases (ranging from 11-33%) in detection probability for five species resulting from the presence of game trails. For six species detection probability was also influenced by the presence of a log feature. This bias was most pronounced for the three rodents investigated, where in all cases detection probability was substantially higher (24.9-38.2%) at log cameras. Our results indicate that small-scale factors, including the presence of game trails and other features, can have significant impacts on species detection when camera traps are employed. Significant biases may result if the presence and quality of these features are not documented and either incorporated into analytical procedures, or controlled for in study design.

  16. The association of colonoscopy quality indicators with the detection of screen-relevant lesions, adverse events, and postcolonoscopy cancers in an asymptomatic Canadian colorectal cancer screening population.

    PubMed

    Hilsden, Robert J; Dube, Catherine; Heitman, Steven J; Bridges, Ronald; McGregor, S Elizabeth; Rostom, Alaa

    2015-11-01

    Although several quality indicators of colonoscopy have been defined, quality assurance activities should be directed at the measurement of quality indicators that are predictive of key screening colonoscopy outcomes. The goal of this study was to examine the association among established quality indicators and the detection of screen-relevant lesions (SRLs), adverse events, and postcolonoscopy cancers. Historical cohort study. Canadian colorectal cancer screening center. A total of 18,456 asymptomatic men and women ages 40 to 74, at either average risk or increased risk for colorectal cancer because of a family history, who underwent a screening colonoscopy from 2008 to 2010. Using univariate and multivariate analyses, we explored the association among procedural quality indicators and 3 colonoscopy outcomes: detection of SRLs, adverse events, and postcolonoscopy cancers. The crude rates of SRLs, adverse events, and postcolonoscopy cancers were 240, 6.44, and .54 per 1000 colonoscopies, respectively. Several indicators, including endoscopist withdrawal time (OR, 1.3; 95% CI, 1.2-1.4) and cecal intubation rate (OR, 13.9; 95% CI, 1.9-96.9), were associated with the detection of SRLs. No quality indicator was associated with the risk of adverse events. Endoscopist average withdrawal time over 6 minutes (OR, .12; 95% CI, .002-.85) and SRL detection rate over 20% (OR, .17; 95% CI, .03-.74) were associated with a reduced risk of postcolonoscopy cancers. Single-center study. Quality assurance programs should prioritize the measurement of endoscopist average withdrawal time and adenoma (SRL) detection rate. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  17. DECIPHER, a Search-Based Approach to Chimera Identification for 16S rRNA Sequences

    PubMed Central

    Wright, Erik S.; Yilmaz, L. Safak

    2012-01-01

    DECIPHER is a new method for finding 16S rRNA chimeric sequences by the use of a search-based approach. The method is based upon detecting short fragments that are uncommon in the phylogenetic group where a query sequence is classified but frequently found in another phylogenetic group. The algorithm was calibrated for full sequences (fs_DECIPHER) and short sequences (ss_DECIPHER) and benchmarked against WigeoN (Pintail), ChimeraSlayer, and Uchime using artificially generated chimeras. Overall, ss_DECIPHER and Uchime provided the highest chimera detection for sequences 100 to 600 nucleotides long (79% and 81%, respectively), but Uchime's performance deteriorated for longer sequences, while ss_DECIPHER maintained a high detection rate (89%). Both methods had low false-positive rates (1.3% and 1.6%). The more conservative fs_DECIPHER, benchmarked only for sequences longer than 600 nucleotides, had an overall detection rate lower than that of ss_DECIPHER (75%) but higher than those of the other programs. In addition, fs_DECIPHER had the lowest false-positive rate among all the benchmarked programs (<0.20%). DECIPHER was outperformed only by ChimeraSlayer and Uchime when chimeras were formed from closely related parents (less than 10% divergence). Given the differences in the programs, it was possible to detect over 89% of all chimeras with just the combination of ss_DECIPHER and Uchime. Using fs_DECIPHER, we detected between 1% and 2% additional chimeras in the RDP, SILVA, and Greengenes databases from which chimeras had already been removed with Pintail or Bellerophon. DECIPHER was implemented in the R programming language and is directly accessible through a webpage or by downloading the program as an R package (http://DECIPHER.cee.wisc.edu). PMID:22101057

  18. Magnetoelectric Transverse Gradient Sensor with High Detection Sensitivity and Low Gradient Noise

    PubMed Central

    2017-01-01

    We report, theoretically and experimentally, the realization of a high detection performance in a novel magnetoelectric (ME) transverse gradient sensor based on the large ME effect and the magnetic field gradient (MFG) technique in a pair of magnetically-biased, electrically-shielded, and mechanically-enclosed ME composites having a transverse orientation and an axial separation. The output voltage of the gradient sensor is directly obtained from the transverse MFG-induced difference in ME voltage between the two ME composites and is calibrated against transverse MFGs to give a high detection sensitivity of 0.4–30.6 V/(T/m), a strong common-mode magnetic field noise rejection rate of <−14.5 dB, a small input-output nonlinearity of <10 ppm, and a low gradient noise of 0.16–620 nT/m/Hz in a broad frequency range of 1 Hz–170 kHz under a small baseline of 35 mm. An analysis of experimental gradient noise spectra obtained in a magnetically-unshielded laboratory environment reveals the domination of the pink (1/f) noise, dielectric loss noise, and power-frequency noise below 3 kHz, in addition to the circuit noise above 3 kHz, in the gradient sensor. The high detection performance, together with the added merit of passive and direct ME conversion by the large ME effect in the ME composites, makes the gradient sensor suitable for the passive, direct, and broadband detection of transverse MFGs. PMID:29068428

  19. Magnetoelectric Transverse Gradient Sensor with High Detection Sensitivity and Low Gradient Noise.

    PubMed

    Zhang, Mingji; Or, Siu Wing

    2017-10-25

    We report, theoretically and experimentally, the realization of a high detection performance in a novel magnetoelectric (ME) transverse gradient sensor based on the large ME effect and the magnetic field gradient (MFG) technique in a pair of magnetically-biased, electrically-shielded, and mechanically-enclosed ME composites having a transverse orientation and an axial separation. The output voltage of the gradient sensor is directly obtained from the transverse MFG-induced difference in ME voltage between the two ME composites and is calibrated against transverse MFGs to give a high detection sensitivity of 0.4-30.6 V/(T/m), a strong common-mode magnetic field noise rejection rate of <-14.5 dB, a small input-output nonlinearity of <10 ppm, and a low gradient noise of 0.16-620 nT/m/ Hz in a broad frequency range of 1 Hz-170 kHz under a small baseline of 35 mm. An analysis of experimental gradient noise spectra obtained in a magnetically-unshielded laboratory environment reveals the domination of the pink (1/ f ) noise, dielectric loss noise, and power-frequency noise below 3 kHz, in addition to the circuit noise above 3 kHz, in the gradient sensor. The high detection performance, together with the added merit of passive and direct ME conversion by the large ME effect in the ME composites, makes the gradient sensor suitable for the passive, direct, and broadband detection of transverse MFGs.

  20. A novel five-wire micro anemometer with 3D directionality for low speed air flow detection and acoustic particle velocity detecting capability

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Chang, Wenhan; Gao, Chengchen; Hao, Yilong

    2018-04-01

    In this paper, a novel five-wire micro-fabricated anemometer with 3D directionality based on calorimetric principle is proposed, which is capable of measuring low speed airflow. This structure is realized by vertically bonding two different dies, which can be fabricated on the same wafer resulting in a simple fabrication process. Experiments on speed lower than 200 mm s-1 are conducted, showing good repeatability and directionality. The speed of airflow is controlled by the volumetric flow rate. The measured velocity sensitivity is 9.4 mV · s m-1, with relative direction sensitivity of 37.1 dB. The deviation between the expected and the measured directivity is analyzed by both theories and simulations. A correction procedure is proposed and turns out to be useful to eliminate this deviation. To further explore the potential of our device, we expose it to acoustic plane waves in a standing wave tube, showing consistent planar directivity of figure of eight. The measured velocity sensitivity at 1 kHz and 120 dBC is 4.4 mV · s m-1, with relative direction sensitivity of 27.0 dB. By using the correction method proposed above, the maximum angle error is about  ±2°, showing its good directionality accuracy.

  1. Directing driver attention with augmented reality cues

    PubMed Central

    Rusch, Michelle L.; Schall, Mark C.; Gavin, Patrick; Lee, John D.; Dawson, Jeffrey D.; Vecera, Shaun; Rizzo, Matthew

    2013-01-01

    This simulator study evaluated the effects of augmented reality (AR) cues designed to direct the attention of experienced drivers to roadside hazards. Twenty-seven healthy middle-aged licensed drivers with a range of attention capacity participated in a 54 mile (1.5 hour) drive in an interactive fixed-base driving simulator. Each participant received AR cues to potential roadside hazards in six simulated straight (9 mile long) rural roadway segments. Drivers were evaluated on response time for detecting a potentially hazardous event, detection accuracy for target (hazard) and non-target objects, and headway with respect to the hazards. Results showed no negative outcomes associated with interference. AR cues did not impair perception of non-target objects, including for drivers with lower attentional capacity. Results showed near significant response time benefits for AR cued hazards. AR cueing increased response rate for detecting pedestrians and warning signs but not vehicles. AR system false alarms and misses did not impair driver responses to potential hazards. PMID:24436635

  2. Detection and genotyping of enteroviruses in cerebrospinal fluid in patients in Victoria, Australia, 2007-2013.

    PubMed

    Papadakis, Georgina; Chibo, Doris; Druce, Julian; Catton, Michael; Birch, Chris

    2014-09-01

    Genotyping by VP1 fragment polymerase chain reaction (PCR) and nucleic acid sequencing to detect enterovirus (EV) genotypes was performed directly on 729 EV PCR positive cerebrospinal fluid (CSF) samples collected between 2007 and 2012 from Victorian hospital inpatients. The overall genotype identification rate from CSF-positive material was 43%. The four most common genotypes identified were Echovirus 6 (24%), Echovirus 30 (17%), Echovirus 25 (10%), and Coxsackievirus A9 (10%), together comprising 61% of all EVs typed. The seasonal distribution of all EVs identified followed the recognized pattern of mainly summer epidemics. Three of the four predominant genotypes were present in each of the 6 years in which the study was conducted, with 20 other EV genotypes also detected, often in only a single year. Genotyping of EVs directly in CSF is faster, simpler and more sensitive than traditional virus neutralization assays performed on EV positive samples. © 2014 Wiley Periodicals, Inc.

  3. TRENTOOL: A Matlab open source toolbox to analyse information flow in time series data with transfer entropy

    PubMed Central

    2011-01-01

    Background Transfer entropy (TE) is a measure for the detection of directed interactions. Transfer entropy is an information theoretic implementation of Wiener's principle of observational causality. It offers an approach to the detection of neuronal interactions that is free of an explicit model of the interactions. Hence, it offers the power to analyze linear and nonlinear interactions alike. This allows for example the comprehensive analysis of directed interactions in neural networks at various levels of description. Here we present the open-source MATLAB toolbox TRENTOOL that allows the user to handle the considerable complexity of this measure and to validate the obtained results using non-parametrical statistical testing. We demonstrate the use of the toolbox and the performance of the algorithm on simulated data with nonlinear (quadratic) coupling and on local field potentials (LFP) recorded from the retina and the optic tectum of the turtle (Pseudemys scripta elegans) where a neuronal one-way connection is likely present. Results In simulated data TE detected information flow in the simulated direction reliably with false positives not exceeding the rates expected under the null hypothesis. In the LFP data we found directed interactions from the retina to the tectum, despite the complicated signal transformations between these stages. No false positive interactions in the reverse directions were detected. Conclusions TRENTOOL is an implementation of transfer entropy and mutual information analysis that aims to support the user in the application of this information theoretic measure. TRENTOOL is implemented as a MATLAB toolbox and available under an open source license (GPL v3). For the use with neural data TRENTOOL seamlessly integrates with the popular FieldTrip toolbox. PMID:22098775

  4. TRENTOOL: a Matlab open source toolbox to analyse information flow in time series data with transfer entropy.

    PubMed

    Lindner, Michael; Vicente, Raul; Priesemann, Viola; Wibral, Michael

    2011-11-18

    Transfer entropy (TE) is a measure for the detection of directed interactions. Transfer entropy is an information theoretic implementation of Wiener's principle of observational causality. It offers an approach to the detection of neuronal interactions that is free of an explicit model of the interactions. Hence, it offers the power to analyze linear and nonlinear interactions alike. This allows for example the comprehensive analysis of directed interactions in neural networks at various levels of description. Here we present the open-source MATLAB toolbox TRENTOOL that allows the user to handle the considerable complexity of this measure and to validate the obtained results using non-parametrical statistical testing. We demonstrate the use of the toolbox and the performance of the algorithm on simulated data with nonlinear (quadratic) coupling and on local field potentials (LFP) recorded from the retina and the optic tectum of the turtle (Pseudemys scripta elegans) where a neuronal one-way connection is likely present. In simulated data TE detected information flow in the simulated direction reliably with false positives not exceeding the rates expected under the null hypothesis. In the LFP data we found directed interactions from the retina to the tectum, despite the complicated signal transformations between these stages. No false positive interactions in the reverse directions were detected. TRENTOOL is an implementation of transfer entropy and mutual information analysis that aims to support the user in the application of this information theoretic measure. TRENTOOL is implemented as a MATLAB toolbox and available under an open source license (GPL v3). For the use with neural data TRENTOOL seamlessly integrates with the popular FieldTrip toolbox.

  5. Fission meter and neutron detection using poisson distribution comparison

    DOEpatents

    Rowland, Mark S; Snyderman, Neal J

    2014-11-18

    A neutron detector system and method for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. Comparison of the observed neutron count distribution with a Poisson distribution is performed to distinguish fissile material from non-fissile material.

  6. 2 Tbit/s free-space data transmission on two orthogonal orbital-angular-momentum beams each carrying 25 WDM channels.

    PubMed

    Fazal, Irfan M; Ahmed, Nisar; Wang, Jian; Yang, Jeng-Yuan; Yan, Yan; Shamee, Bishara; Huang, Hao; Yue, Yang; Dolinar, Sam; Tur, Moshe; Willner, Alan E

    2012-11-15

    We demonstrate a 2 Tbit/s free-space data link using two orthogonal orbital angular momentum beams each carrying 25 different wavelength-division-multiplexing channels. We measure the performance for different modulation formats, including directly detected 40 Gbit/s nonreturn-to-zero (NRZ) differential phase-shift keying, 40 Gbit/s NRZ on-off keying, and coherently-detected 10 Gbaud NRZ quadrature phase-shift keying, and achieve low bit error rates with penalties less than 5 dB.

  7. An Analysis of the Malassezia Species Distribution in the Skin of Patients with Pityriasis Versicolor in Chengdu, China

    PubMed Central

    Xie, Zhen; Ran, Yuping; Zhang, Hao; Zhang, Min; Wan, Huiying; Li, Conghui

    2014-01-01

    Pityriasis versicolor (PV) is a common clinical problem associated with Malassezia species (Malassezia spp.). Controversies remain regarding the specific species involved in the development of PV. This study analyzed the difference in Malassezia spp. distribution in lesional and nonlesional skin in Chinese PV patients. A paired design was applied. Lesional and nonlesional scales from 24 cases were collected; real-time fluorescence quantitative PCR was used to detect 10 different Malassezia spp. In lesional skin, the highest detection rates were for M. globosa (95.8%), M. restricta (91.7%), and M. sympodialis (50.0%). In nonlesional skin, the highest detection rates were for M. globosa (87.5%), M. restricta (79.2%), and M. dermatis (33.3%). A significant difference in the detection rate was only found for M. sympodialis (50.8% versus 20.8%, P = 0.04). Compared with nonlesional skin, the amount of M. globosa, M. restricta, and M. sympodialis in lesional skin was significantly higher (3.8 ± 1.3,  2.5 ± 1.1, and 3.2 ± 1.6 times higher, resp.). The results of this study do not indicate that M. globosa and M. restricta are directly correlated with PV development; however, M. sympodialis is more likely related to PV development in Chinese individuals. PMID:25177714

  8. An analysis of the Malassezia species distribution in the skin of patients with pityriasis versicolor in Chengdu, China.

    PubMed

    Xie, Zhen; Ran, Yuping; Zhang, Hao; Zhang, Min; Wan, Huiying; Li, Conghui

    2014-01-01

    Pityriasis versicolor (PV) is a common clinical problem associated with Malassezia species (Malassezia spp.). Controversies remain regarding the specific species involved in the development of PV. This study analyzed the difference in Malassezia spp. distribution in lesional and nonlesional skin in Chinese PV patients. A paired design was applied. Lesional and nonlesional scales from 24 cases were collected; real-time fluorescence quantitative PCR was used to detect 10 different Malassezia spp. In lesional skin, the highest detection rates were for M. globosa (95.8%), M. restricta (91.7%), and M. sympodialis (50.0%). In nonlesional skin, the highest detection rates were for M. globosa (87.5%), M. restricta (79.2%), and M. dermatis (33.3%). A significant difference in the detection rate was only found for M. sympodialis (50.8% versus 20.8%, P = 0.04). Compared with nonlesional skin, the amount of M. globosa, M. restricta, and M. sympodialis in lesional skin was significantly higher (3.8 ± 1.3,  2.5 ± 1.1, and 3.2 ± 1.6 times higher, resp.). The results of this study do not indicate that M. globosa and M. restricta are directly correlated with PV development; however, M. sympodialis is more likely related to PV development in Chinese individuals.

  9. Distribution and seasonal differences in Pacific Lamprey and Lampetra spp eDNA across 18 Puget Sound watersheds

    USGS Publications Warehouse

    Ostberg, Carl O.; Chase, Dorothy M.; Hayes, Michael C.; Duda, Jeffrey J.

    2018-01-01

    Lampreys have a worldwide distribution, are functionally important to ecological communities and serve significant roles in many cultures. In Pacific coast drainages of North America, lamprey populations have suffered large declines. However, lamprey population status and trends within many areas of this region are unknown and such information is needed for advancing conservation goals. We developed two quantitative PCR-based, aquatic environmental DNA (eDNA) assays for detection of Pacific Lamprey (Entosphenus tridentatus) and Lampetra spp, using locked nucleic acids (LNAs) in the probe design. We used these assays to characterize the spatial distribution of lamprey in 18 watersheds of Puget Sound, Washington, by collecting water samples in spring and fall. Pacific Lamprey and Lampetraspp were each detected in 14 watersheds and co-occurred in 10 watersheds. Lamprey eDNA detection rates were much higher in spring compared to fall. Specifically, the Pacific Lamprey eDNA detection rate was 3.5 times higher in spring and the Lampetra spp eDNA detection rate was 1.5 times higher in spring even though larval lamprey are present in streams year-round. This significant finding highlights the importance of seasonality on eDNA detection. Higher stream discharge in the fall likely contributed to reduced eDNA detection rates, although seasonal life history events may have also contributed. These eDNA assays differentiate Pacific Lamprey and Lampetra spp across much of their range along the west coast of North America. Sequence analysis indicates the Pacific Lamprey assay also targets other Entosphenus spp and indicates the Lampetra spp assay may have limited or no capability of detecting Lampetra in some locations south of the Columbia River Basin. Nevertheless, these assays will serve as a valuable tool for resource managers and have direct application to lamprey conservation efforts, such as mapping species distributions, occupancy modeling, and monitoring translocations and reintroductions.

  10. Distribution and seasonal differences in Pacific Lamprey and Lampetra spp eDNA across 18 Puget Sound watersheds

    PubMed Central

    Hayes, Michael C.; Duda, Jeffrey J.

    2018-01-01

    Lampreys have a worldwide distribution, are functionally important to ecological communities and serve significant roles in many cultures. In Pacific coast drainages of North America, lamprey populations have suffered large declines. However, lamprey population status and trends within many areas of this region are unknown and such information is needed for advancing conservation goals. We developed two quantitative PCR-based, aquatic environmental DNA (eDNA) assays for detection of Pacific Lamprey (Entosphenus tridentatus) and Lampetra spp, using locked nucleic acids (LNAs) in the probe design. We used these assays to characterize the spatial distribution of lamprey in 18 watersheds of Puget Sound, Washington, by collecting water samples in spring and fall. Pacific Lamprey and Lampetra spp were each detected in 14 watersheds and co-occurred in 10 watersheds. Lamprey eDNA detection rates were much higher in spring compared to fall. Specifically, the Pacific Lamprey eDNA detection rate was 3.5 times higher in spring and the Lampetra spp eDNA detection rate was 1.5 times higher in spring even though larval lamprey are present in streams year-round. This significant finding highlights the importance of seasonality on eDNA detection. Higher stream discharge in the fall likely contributed to reduced eDNA detection rates, although seasonal life history events may have also contributed. These eDNA assays differentiate Pacific Lamprey and Lampetra spp across much of their range along the west coast of North America. Sequence analysis indicates the Pacific Lamprey assay also targets other Entosphenus spp and indicates the Lampetra spp assay may have limited or no capability of detecting Lampetra in some locations south of the Columbia River Basin. Nevertheless, these assays will serve as a valuable tool for resource managers and have direct application to lamprey conservation efforts, such as mapping species distributions, occupancy modeling, and monitoring translocations and reintroductions. PMID:29576966

  11. Earth's magnetic field as a radiator to detect cosmic ray electrons of energy greater than 10 to the 12th eV

    NASA Technical Reports Server (NTRS)

    Balasubrahmanyan, V. K.; Stephens, S. A.

    1983-01-01

    Synchrotron emission by a high-energy electron in the geomagnetic field and its dependence upon different arrival directions over Palestine, Texas, where major balloon-borne experiments are being conducted, is studied. The dependence of detector response on the arrival direction of electron, the different criteria which are adopted to identify an electron event, the area of the detector, and the energy of the electron are discussed. An omnidirectional circular detector is used to examine whether it is possible to determine the energy of an electron without knowing its arrival direction. The collecting power of a detector is estimated as a function of the energy of electrons for different detector areas with different selection criteria, and this information is used to calculate the event rates expected by folding in the energy spectrum of cosmic ray electrons to show the viability of detecting cosmic ray electrons at energies greater than a few TeV.

  12. Long-term follow up of gallbladder polyps.

    PubMed

    Park, Jeong Youp; Hong, Sung Pil; Kim, Yoon Jae; Kim, Hong Jeoung; Kim, Hee Man; Cho, Jae Hee; Park, Seung Woo; Song, Si Young; Chung, Jae Bock; Bang, Seungmin

    2009-02-01

    The management of gallbladder polyps (GBP) is directly linked to the early diagnosis of gallbladder cancer (GBC). This study aimed to evaluate the malignant risk of GBP. In total, 1558 patients diagnosed with GBP were followed. Neoplastic polyps were defined as GBC and its premalignant lesions. The risk for malignancy was estimated with the cumulative detection rate of neoplastic polyps. Thirty-three cases (2.1%) were diagnosed with neoplastic polyps. The cumulative detection rates of neoplastic polyps were 1.7% at 1 year, 2.8% at 5 years, and 4% at 8 years after diagnosis. The size of GBP and the presence of gallstones were risk factors for neoplastic polyps. Polyps > or = 10 mm had a 24.2 times greater risk of malignancy than polyps < 10 mm. However, 15 of 33 neoplastic polyps (45.5%) were < 10 mm at the time of diagnosis of GBP. During follow up in 36 (3.5%) of 1027 cases, an increase in size was detected; of these, nine (25%) had neoplastic polyps. Even small polyps have a risk of malignancy, and careful long-term follow up of GBP will help detect and treat early GBC.

  13. Processing Images of Craters for Spacecraft Navigation

    NASA Technical Reports Server (NTRS)

    Cheng, Yang; Johnson, Andrew E.; Matthies, Larry H.

    2009-01-01

    A crater-detection algorithm has been conceived to enable automation of what, heretofore, have been manual processes for utilizing images of craters on a celestial body as landmarks for navigating a spacecraft flying near or landing on that body. The images are acquired by an electronic camera aboard the spacecraft, then digitized, then processed by the algorithm, which consists mainly of the following steps: 1. Edges in an image detected and placed in a database. 2. Crater rim edges are selected from the edge database. 3. Edges that belong to the same crater are grouped together. 4. An ellipse is fitted to each group of crater edges. 5. Ellipses are refined directly in the image domain to reduce errors introduced in the detection of edges and fitting of ellipses. 6. The quality of each detected crater is evaluated. It is planned to utilize this algorithm as the basis of a computer program for automated, real-time, onboard processing of crater-image data. Experimental studies have led to the conclusion that this algorithm is capable of a detection rate >93 percent, a false-alarm rate <5 percent, a geometric error <0.5 pixel, and a position error <0.3 pixel.

  14. NANOGrav Constraints on Gravitational Wave Bursts with Memory

    NASA Astrophysics Data System (ADS)

    Arzoumanian, Z.; Brazier, A.; Burke-Spolaor, S.; Chamberlin, S. J.; Chatterjee, S.; Christy, B.; Cordes, J. M.; Cornish, N. J.; Demorest, P. B.; Deng, X.; Dolch, T.; Ellis, J. A.; Ferdman, R. D.; Fonseca, E.; Garver-Daniels, N.; Jenet, F.; Jones, G.; Kaspi, V. M.; Koop, M.; Lam, M. T.; Lazio, T. J. W.; Levin, L.; Lommen, A. N.; Lorimer, D. R.; Luo, J.; Lynch, R. S.; Madison, D. R.; McLaughlin, M. A.; McWilliams, S. T.; Nice, D. J.; Palliyaguru, N.; Pennucci, T. T.; Ransom, S. M.; Siemens, X.; Stairs, I. H.; Stinebring, D. R.; Stovall, K.; Swiggum, J.; Vallisneri, M.; van Haasteren, R.; Wang, Y.; Zhu, W. W.; NANOGrav Collaboration

    2015-09-01

    Among efforts to detect gravitational radiation, pulsar timing arrays are uniquely poised to detect “memory” signatures, permanent perturbations in spacetime from highly energetic astrophysical events such as mergers of supermassive black hole binaries. The North American Nanohertz Observatory for Gravitational Waves (NANOGrav) observes dozens of the most stable millisecond pulsars using the Arecibo and Green Bank radio telescopes in an effort to study, among other things, gravitational wave memory. We herein present the results of a search for gravitational wave bursts with memory (BWMs) using the first five years of NANOGrav observations. We develop original methods for dramatically speeding up searches for BWM signals. In the directions of the sky where our sensitivity to BWMs is best, we would detect mergers of binaries with reduced masses of {10}9 {M}⊙ out to distances of 30 Mpc; such massive mergers in the Virgo cluster would be marginally detectable. We find no evidence for BWMs. However, with our non-detection, we set upper limits on the rate at which BWMs of various amplitudes could have occurred during the time spanned by our data—e.g., BWMs with amplitudes greater than 10-13 must encounter the Earth at a rate less than 1.5 yr-1.

  15. Length polymorphism scanning is an efficient approach for revealing chloroplast DNA variation.

    Treesearch

    Matthew E. Horning; Richard C. Cronn

    2006-01-01

    Phylogeographic and population genetic screens of chloroplast DNA (cpDNA) provide insights into seedbased gene flow in angiosperms, yet studies are frequently hampered by the low mutation rate of this genome. Detection methods for intraspecific variation can be either direct (DNA sequencing) or indirect (PCR-RFLP), although no single method incorporates the best...

  16. Fission meter

    DOEpatents

    Rowland, Mark S [Alamo, CA; Snyderman, Neal J [Berkeley, CA

    2012-04-10

    A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source.

  17. Rapid method for measuring rotenone in water at piscicidal concentrations

    USGS Publications Warehouse

    Dawson, V.K.; Harman, P.D.; Schultz, D.P.; Allen, J.L.

    1983-01-01

    A high-performance liquid chromatography (HPLC) procedure that is rapid, specific, and sensitive (limit of detection <0.005 mg/liter) was developed for monitoring application and degradation rates of rotenone. For analysis, a water sample is buffered to pH 5 and injected through a Sep Pak(R) C18 disposable cartridge. The cartridge adsorbs and retains the rotenone which then can be eluted quantitatively from the cartridge with a small volume of methanol. This step effectively concentrates the sample and provides sample cleanup. The methanol extract is analyzed directly by HPLC on an MCH 10 reverse-phase column; methanol: water (75:25, volume : volume) is the mobile phase and flow rate is 1.5 ml/minute. The rotenone is detected by ultraviolet spectrophotometry at a wavelength of 295 nm.

  18. Modeling of a latent fault detector in a digital system

    NASA Technical Reports Server (NTRS)

    Nagel, P. M.

    1978-01-01

    Methods of modeling the detection time or latency period of a hardware fault in a digital system are proposed that explain how a computer detects faults in a computational mode. The objectives were to study how software reacts to a fault, to account for as many variables as possible affecting detection and to forecast a given program's detecting ability prior to computation. A series of experiments were conducted on a small emulated microprocessor with fault injection capability. Results indicate that the detecting capability of a program largely depends on the instruction subset used during computation and the frequency of its use and has little direct dependence on such variables as fault mode, number set, degree of branching and program length. A model is discussed which employs an analog with balls in an urn to explain the rate of which subsequent repetitions of an instruction or instruction set detect a given fault.

  19. Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; Francucci, M.; Gaudio, P.; Gelfusa, M.; Martellucci, S.; Richetta, M.; Lo Feudo, T.

    2007-04-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.

  20. 2-micron Pulsed Direct Detection IPDA Lidar for Atmospheric CO2 Measurements

    NASA Astrophysics Data System (ADS)

    Yu, J.; Singh, U.; Petros, M.

    2012-12-01

    A 2-micron high energy, pulsed Integrated Path Differential Absorption (IPDA) lidar is being developed for atmospheric CO2 measurements. Development of this lidar heavily leverages the 2-micron laser technologies developed in LaRC over the last decade. The high pulse energy, direct detection lidar operating at CO2 2-micron absorption band provides an alternate approach to measure CO2 concentrations with significant advantages. It is expected to provide high-precision measurement capability by unambiguously eliminating contamination from aerosols and clouds that can bias the IPDA measurement. Our objective is to integrate an existing high energy double-pulsed 2-micron laser transmitter with a direct detection receiver and telescope to enable an airborne capability to perform a first proof of principle demonstration of airborne direct detection CO2 measurements. The 2-micron transmitter provides 100mJ at 10Hz with double pulse format specifically designed for DIAL/IPDA instrument. The compact, rugged, highly reliable transceiver is based on unique Ho:Tm:YLF high-energy 2-micron pulsed laser technology. All the optical mounts are custom designed and have space heritage. A 16-inch diameter telescope has been designed and being manufactured for the direct detection lidar. The detector is an InGaAs Positive-Intrinsic-Negative (PIN) photodiode manufactured by Hamamatsu Corporation. The performance of the detector is characterized at various operating temperatures and bias voltages for spectral response, NEP, response time, dynamic range, and linearity. A collinear lidar structure is designed to be integrated to NASA UC12 or B200 research aircrafts. This paper will describe the design of the airborne 2-micron pulsed IPDA lidar system; the lidar operation parameters; the wavelength pair selection; laser transmitter energy, pulse rate, beam divergence, double pulse generation and accurate frequency control; detector characterization; telescope design; lidar structure design; and lidar signal to noise ratio estimation. The first engineering flight is scheduled at the end of next year.

  1. Effects of Airgun Sounds on Bowhead Whale Calling Rates: Evidence for Two Behavioral Thresholds

    PubMed Central

    Blackwell, Susanna B.; Nations, Christopher S.; McDonald, Trent L.; Thode, Aaron M.; Mathias, Delphine; Kim, Katherine H.; Greene, Charles R.; Macrander, A. Michael

    2015-01-01

    In proximity to seismic operations, bowhead whales (Balaena mysticetus) decrease their calling rates. Here, we investigate the transition from normal calling behavior to decreased calling and identify two threshold levels of received sound from airgun pulses at which calling behavior changes. Data were collected in August–October 2007–2010, during the westward autumn migration in the Alaskan Beaufort Sea. Up to 40 directional acoustic recorders (DASARs) were deployed at five sites offshore of the Alaskan North Slope. Using triangulation, whale calls localized within 2 km of each DASAR were identified and tallied every 10 minutes each season, so that the detected call rate could be interpreted as the actual call production rate. Moreover, airgun pulses were identified on each DASAR, analyzed, and a cumulative sound exposure level was computed for each 10-min period each season (CSEL10-min). A Poisson regression model was used to examine the relationship between the received CSEL10-min from airguns and the number of detected bowhead calls. Calling rates increased as soon as airgun pulses were detectable, compared to calling rates in the absence of airgun pulses. After the initial increase, calling rates leveled off at a received CSEL10-min of ~94 dB re 1 μPa2-s (the lower threshold). In contrast, once CSEL10-min exceeded ~127 dB re 1 μPa2-s (the upper threshold), whale calling rates began decreasing, and when CSEL10-min values were above ~160 dB re 1 μPa2-s, the whales were virtually silent. PMID:26039218

  2. Effects of airgun sounds on bowhead whale calling rates: evidence for two behavioral thresholds.

    PubMed

    Blackwell, Susanna B; Nations, Christopher S; McDonald, Trent L; Thode, Aaron M; Mathias, Delphine; Kim, Katherine H; Greene, Charles R; Macrander, A Michael

    2015-01-01

    In proximity to seismic operations, bowhead whales (Balaena mysticetus) decrease their calling rates. Here, we investigate the transition from normal calling behavior to decreased calling and identify two threshold levels of received sound from airgun pulses at which calling behavior changes. Data were collected in August-October 2007-2010, during the westward autumn migration in the Alaskan Beaufort Sea. Up to 40 directional acoustic recorders (DASARs) were deployed at five sites offshore of the Alaskan North Slope. Using triangulation, whale calls localized within 2 km of each DASAR were identified and tallied every 10 minutes each season, so that the detected call rate could be interpreted as the actual call production rate. Moreover, airgun pulses were identified on each DASAR, analyzed, and a cumulative sound exposure level was computed for each 10-min period each season (CSEL10-min). A Poisson regression model was used to examine the relationship between the received CSEL10-min from airguns and the number of detected bowhead calls. Calling rates increased as soon as airgun pulses were detectable, compared to calling rates in the absence of airgun pulses. After the initial increase, calling rates leveled off at a received CSEL10-min of ~94 dB re 1 μPa2-s (the lower threshold). In contrast, once CSEL10-min exceeded ~127 dB re 1 μPa2-s (the upper threshold), whale calling rates began decreasing, and when CSEL10-min values were above ~160 dB re 1 μPa2-s, the whales were virtually silent.

  3. Tracer injection sites and combinations for sentinel lymph node detection in patients with endometrial cancer.

    PubMed

    Niikura, Hitoshi; Kaiho-Sakuma, Michiko; Tokunaga, Hideki; Toyoshima, Masafumi; Utsunomiya, Hiroki; Nagase, Satoru; Takano, Tadao; Watanabe, Mika; Ito, Kiyoshi; Yaegashi, Nobuo

    2013-11-01

    The aim of the present study was to clarify the most effective combination of injected tracer types and injection sites in order to detect sentinel lymph nodes (SLNs) in early endometrial cancer. The study included 100 consecutive patients with endometrial cancer treated at Tohoku University Hospital between June 2001 and December 2012. The procedure for SLN identification entailed either radioisotope (RI) injection into the endometrium during hysteroscopy (55 cases) or direct RI injection into the uterine cervix (45 cases). A combination of blue dye injected into the uterine cervix or uterine body intraoperatively in addition to preoperative RI injection occurred in 69 of 100 cases. All detected SLNs were recorded according to the individual tracer and the resultant staging from this method was compared to the final pathology of lymph node metastases including para-aortic nodes. SLN detection rate was highest (96%) by cervical RI injection; however, no SLNs were detected in para-aortic area. Para-aortic SLNs were detected only by hysteroscopic RI injection (56%). All cases with pelvic lymph node metastases were detected by pelvic SLN biopsy. Isolated positive para-aortic lymph nodes were detected in 3 patients. Bilateral SLN detection rate was high (96%; 26 of 27 cases) by cervical RI injection combined with dye. RI injection into the uterine cervix is highly sensitive in detection of SLN metastasis in early stage endometrial cancer. It is a useful and safe modality when combined with blue dye injection into the uterine body. © 2013.

  4. Association between Helicobacter pylori and intestinal parasites in an Añu indigenous community of Venezuela.

    PubMed

    Fuenmayor-Boscán, Alisbeth D; Hernández, Ileana M; Valero, Kutchynskaya J; Paz, América M; Sandrea, Lisette B; Rivero, Zulbey

    2016-03-01

    Helicobacter pylori (Hp) and enteroparasite infections are highly prevalent in populations with poor living conditions, like the Amerindian communities. Identifying associations between both types of infectious agents could help to detect shared risk factors or transmission routes in these minority ethnic groups. Therefore, the prevalence and association between Hp and enteroparasites were investigated in an indigenous community whose living conditions favor such infectious diseases. Seropositivity (anti-Hp-specific IgG) and active infection (stool antigen test), intestinal parasitosis (direct and concentrated coproparasitological test, methylene blue, and Kinyoun stains), and risk factors for fecal-oral transmission were determined in 167 children and 151 adults of the Añu indigenous community living at the Sinamaica Lagoon, in Venezuela. A high rate of Hp infection (seropositivity and active infection) and enteroparasitosis was evidenced, as expected. Some significant associations were detected: direct associations between Hp and polyparasitic infection, helminths, and protozoan (particularly in children); inverse association between Hp and Giardia lamblia. No shared epidemiological factors were identified for Hp and the detected intestinal parasites, probably due to overlapping factors. Direct associations detected support the participation of the fecal-oral route in the transmission of the involved infectious agents. Inverse relationship (Hp) and G. lamblia may suggest the existence of antagonistic interactions between them. Further research is required to elucidate the mechanisms underlying these associations.

  5. Aircraft Detection in High-Resolution SAR Images Based on a Gradient Textural Saliency Map

    PubMed Central

    Tan, Yihua; Li, Qingyun; Li, Yansheng; Tian, Jinwen

    2015-01-01

    This paper proposes a new automatic and adaptive aircraft target detection algorithm in high-resolution synthetic aperture radar (SAR) images of airport. The proposed method is based on gradient textural saliency map under the contextual cues of apron area. Firstly, the candidate regions with the possible existence of airport are detected from the apron area. Secondly, directional local gradient distribution detector is used to obtain a gradient textural saliency map in the favor of the candidate regions. In addition, the final targets will be detected by segmenting the saliency map using CFAR-type algorithm. The real high-resolution airborne SAR image data is used to verify the proposed algorithm. The results demonstrate that this algorithm can detect aircraft targets quickly and accurately, and decrease the false alarm rate. PMID:26378543

  6. Asm-Triggered too Observations of Z Sources at Low Accretion Rate

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    We propose to perform a pointed observation if the ASM shows that a Z source has entered a state of low accretion rate. This would provide a unique opportunity to detect millisecond pulsations. In Sco X-1 we would expect to discover beat-frequency QPO, and could perform a unique high count rate study of them. At sufficiently low accretion rate it would be possible to study the accretion flow when the magnetospheric radius approaches the corotation radius. The frequency of the horizontal branch QPO should go to zero here, and centrifugal inhibition of the accretion should set in, providing direct tests of the magnetospheric model of Z sources.

  7. Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.

    PubMed

    Marchon, Niyan; Naik, Gourish; Pai, K R

    2018-01-01

    Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal's well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F 1 ) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.

  8. [Prevalence of respiratory syncytial virus infection in hospitalized children at a children's hospital and effects of climate change on the prevalence in Suzhou, China].

    PubMed

    Geng, Jia; Guo, Wan-Liang; Zhang, Xue-Lan

    2015-05-01

    To investigate the prevalence of respiratory syncytial virus (RSV) infection in hospitalized children and the relationship between the prevalence and the climate change in Suzhou, China. A total of 42 664 nasopharyngeal secretions from hospitalized children with acute respiratory infection at the Suzhou Children's Hospital were screened for RSV antigens using direct immunofluorescence. Monthly meteorological data (mean monthly air temperature, monthly relative humidity, monthly rainfall, total monthly sunshine duration, and mean monthly wind velocity) in Suzhou between 2001 and 2011 were collected. The correlations between RSV detection rate and climatic factors were evaluated using correlation and stepwise regression analysis. The annual RSV infection rate in hospitalized children with respiratory infection in the Suzhou Children's Hospital varied between 11.85% and 27.30% from 2001 to 2011. In the 9 epidemic seasons, each spanning from November to April of the next year, from 2001 to 2010, the RSV detection rates were 40.75%, 22.72%, 39.93%, 27.37%, 42.71%, 21.28%, 38.57%, 19.86%, and 29.73%, respectively; there were significant differences in the detection rate between the epidemic seasons. The monthly RSV detection rate was negatively correlated with mean monthly air temperature, total monthly sunshine duration, monthly rainfall, monthly relative humidity, and mean monthly wind velocity (P<0.05). Stepwise regression analysis showed that mean monthly air temperature fitted into a linear model (R(2)=0.64, P<0.01). From 2001 to 2011, RSV infection in Suzhou was predominantly prevalent between November and April of the next year. As a whole, the infection rate of RSV reached a peak every other year. Air temperature played an important role in the epidemics of RSV infection in Suzhou.

  9. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique.

    PubMed

    Battista, L; Sciuto, S A; Scorza, A

    2013-03-01

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 × 10(-4) m(3)∕s (18.0 l∕min) for the mono-directional sensor and a measurement range of ±3.00 × 10(-4) m(3)∕s (±18.0 l∕min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r(2) is equal to 0.997; for the bi-directional configuration, the coefficient of determination r(2) is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty δQ of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l∕min to a maximum of about 9% at -12.0 l∕min.

  10. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

    NASA Astrophysics Data System (ADS)

    Battista, L.; Sciuto, S. A.; Scorza, A.

    2013-03-01

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 × 10-4 m3/s (18.0 l/min) for the mono-directional sensor and a measurement range of ±3.00 × 10-4 m3/s (±18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r2 is equal to 0.997; for the bi-directional configuration, the coefficient of determination r2 is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty δQ of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

  11. Public private mix model in enhancing tuberculosis case detection in District Thatta, Sindh, Pakistan.

    PubMed

    Ahmed, Jameel; Ahmed, Mubashir; Laghari, A; Lohana, Wasdev; Ali, Sajid; Fatmi, Zafar

    2009-02-01

    To enhance the TB case detection through Public Private Mix (PPM) model by involving private practitioners in collaboration with National TB Control Program, (NTP) in district Thatta. Private practitioners (PPs) of district Thatta involved in treatment of TB cases were requested to participate in the study. All consenting physicians were provided with training on Directly Observed Treatment Short course (DOTS) module. In addition to routine cases, TB cases diagnosed by private practitioners through sputum microscopy were also registered with the district TB control program and medicines were provided by NTP. After intervention of PPM-DOTS change in Case Detection Rate (CDR) were estimated. An increased number of sputum smear positive cases were found in the intervention period--the third quarter of 2007, from 188 to 211 and CDR from 69% to 77%. The improvement in case detection rate was significant as this moderately added to the total number of cases detected from the whole of the district Thatta during the study period. Public private mix (PPM) model was effective in increasing the CDR of TB cases in district Thatta. It is recommended that the public private partnership model in Tuberculosis case detection needs to be taken on a larger scale so as to reduce the heavy TB burden in the country.

  12. Change-based threat detection in urban environments with a forward-looking camera

    NASA Astrophysics Data System (ADS)

    Morton, Kenneth, Jr.; Ratto, Christopher; Malof, Jordan; Gunter, Michael; Collins, Leslie; Torrione, Peter

    2012-06-01

    Roadside explosive threats continue to pose a significant risk to soldiers and civilians in conflict areas around the world. These objects are easy to manufacture and procure, but due to their ad hoc nature, they are difficult to reliably detect using standard sensing technologies. Although large roadside explosive hazards may be difficult to conceal in rural environments, urban settings provide a much more complicated background where seemingly innocuous objects (e.g., piles of trash, roadside debris) may be used to obscure threats. Since direct detection of all innocuous objects would flag too many objects to be of use, techniques must be employed to reduce the number of alarms generated and highlight only a limited subset of possibly threatening regions for the user. In this work, change detection techniques are used to reduce false alarm rates and increase detection capabilities for possible threat identification in urban environments. The proposed model leverages data from multiple video streams collected over the same regions by first applying video aligning and then using various distance metrics to detect changes based on image keypoints in the video streams. Data collected at an urban warfare simulation range at an Eastern US test site was used to evaluate the proposed approach, and significant reductions in false alarm rates compared to simpler techniques are illustrated.

  13. Detection of self-paced reaching movement intention from EEG signals.

    PubMed

    Lew, Eileen; Chavarriaga, Ricardo; Silvoni, Stefano; Millán, José Del R

    2012-01-01

    Future neuroprosthetic devices, in particular upper limb, will require decoding and executing not only the user's intended movement type, but also when the user intends to execute the movement. This work investigates the potential use of brain signals recorded non-invasively for detecting the time before a self-paced reaching movement is initiated which could contribute to the design of practical upper limb neuroprosthetics. In particular, we show the detection of self-paced reaching movement intention in single trials using the readiness potential, an electroencephalography (EEG) slow cortical potential (SCP) computed in a narrow frequency range (0.1-1 Hz). Our experiments with 12 human volunteers, two of them stroke subjects, yield high detection rates prior to the movement onset and low detection rates during the non-movement intention period. With the proposed approach, movement intention was detected around 500 ms before actual onset, which clearly matches previous literature on readiness potentials. Interestingly, the result obtained with one of the stroke subjects is coherent with those achieved in healthy subjects, with single-trial performance of up to 92% for the paretic arm. These results suggest that, apart from contributing to our understanding of voluntary motor control for designing more advanced neuroprostheses, our work could also have a direct impact on advancing robot-assisted neurorehabilitation.

  14. Capacity of optical communications over a lossy bosonic channel with a receiver employing the most general coherent electro-optic feedback control

    NASA Astrophysics Data System (ADS)

    Chung, Hye Won; Guha, Saikat; Zheng, Lizhong

    2017-07-01

    We study the problem of designing optical receivers to discriminate between multiple coherent states using coherent processing receivers—i.e., one that uses arbitrary coherent feedback control and quantum-noise-limited direct detection—which was shown by Dolinar to achieve the minimum error probability in discriminating any two coherent states. We first derive and reinterpret Dolinar's binary-hypothesis minimum-probability-of-error receiver as the one that optimizes the information efficiency at each time instant, based on recursive Bayesian updates within the receiver. Using this viewpoint, we propose a natural generalization of Dolinar's receiver design to discriminate M coherent states, each of which could now be a codeword, i.e., a sequence of N coherent states, each drawn from a modulation alphabet. We analyze the channel capacity of the pure-loss optical channel with a general coherent-processing receiver in the low-photon number regime and compare it with the capacity achievable with direct detection and the Holevo limit (achieving the latter would require a quantum joint-detection receiver). We show compelling evidence that despite the optimal performance of Dolinar's receiver for the binary coherent-state hypothesis test (either in error probability or mutual information), the asymptotic communication rate achievable by such a coherent-processing receiver is only as good as direct detection. This suggests that in the infinitely long codeword limit, all potential benefits of coherent processing at the receiver can be obtained by designing a good code and direct detection, with no feedback within the receiver.

  15. Survey of Anomaly Detection Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, B

    This survey defines the problem of anomaly detection and provides an overview of existing methods. The methods are categorized into two general classes: generative and discriminative. A generative approach involves building a model that represents the joint distribution of the input features and the output labels of system behavior (e.g., normal or anomalous) then applies the model to formulate a decision rule for detecting anomalies. On the other hand, a discriminative approach aims directly to find the decision rule, with the smallest error rate, that distinguishes between normal and anomalous behavior. For each approach, we will give an overview ofmore » popular techniques and provide references to state-of-the-art applications.« less

  16. Fault-tolerant quantum error detection.

    PubMed

    Linke, Norbert M; Gutierrez, Mauricio; Landsman, Kevin A; Figgatt, Caroline; Debnath, Shantanu; Brown, Kenneth R; Monroe, Christopher

    2017-10-01

    Quantum computers will eventually reach a size at which quantum error correction becomes imperative. Quantum information can be protected from qubit imperfections and flawed control operations by encoding a single logical qubit in multiple physical qubits. This redundancy allows the extraction of error syndromes and the subsequent detection or correction of errors without destroying the logical state itself through direct measurement. We show the encoding and syndrome measurement of a fault-tolerantly prepared logical qubit via an error detection protocol on four physical qubits, represented by trapped atomic ions. This demonstrates the robustness of a logical qubit to imperfections in the very operations used to encode it. The advantage persists in the face of large added error rates and experimental calibration errors.

  17. Evaluation of genotype MTBDRplus VER 2.0 line probe assay for the detection of MDR-TB in smear positive and negative sputum samples.

    PubMed

    Meaza, Abyot; Kebede, Abebaw; Yaregal, Zelalem; Dagne, Zekarias; Moga, Shewki; Yenew, Bazezew; Diriba, Getu; Molalign, Helina; Tadesse, Mengistu; Adisse, Desalegn; Getahun, Muluwork; Desta, Kassu

    2017-04-17

    Multi drug resistant tuberculosis (MDR-TB) poses formidable challenges to TB control due to its complex diagnostic and treatment challenges and often associated with a high rate of mortality. Accurate and rapid detection of MDR-TB is critical for timely initiation of treatment. Line Probe Assay (LPA) is a qualitative in vitro diagnostic test based on DNA-STRIP technology for the identification of the M. tuberculosis complex and its resistance to rifampicin (RMP) and/or isoniazid (INH). Hain Lifescience, GmbH, Germany has improved the sensitivity of Genotype MTBDRplus VER 2.0 LPA for the detection of MDR-TB; with the possibility of applying the tool in smear negative sputum samples. A cross sectional study was conducted on 274 presumptive MDR-TB patients referred to the National TB Reference Laboratory (NTRL), Ethiopian Public Health Institute (EPHI) who submitted sputum samples for laboratory diagnosis of drug resistant-TB testing. Seventy-two smear and culture positive samples processed in smear positive direct LPA category and 197 smear negative sputum samples were processed for direct LPA. Among the smear negative samples 145 (73.6%) were culture negative and 26 (13.2%) were culture positive. All specimens were processed using NALC-NaOH method and ZN smear microscopy done from sediments. Genotype MTBDRplus VER 2.0 done from processed sputum sediments and the result was compared against the reference, BACTEC MGIT 960 culture and DST. Sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 assay was determined and P-value <0.05 was considered as statistically significant. The sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 LPA were 96.4, 100, 100 and 96.9%, respectively for the detection of MDR-TB from direct smear positive sputum samples. The sensitivity, specificity, PPV and NPV of Genotype MTBDR plus VER 2.0 LPA were 77.8, 97.2, 82.4 and 97.2%, respectively, for the detection of M. tuberculosis from direct smear negative sputum samples. Fourteen (53.8%) samples had valid results with LPA among the 26 smear negative culture positive samples. The remaining 8 (30.8%) and 4 (15.4%) were invalid and negative with LPA, respectively. The sensitivity and specificity of Genotype MTBDRplus VER 2.0 LPA were 100% for the detection of MDR-TB among 14 direct smear negative and culture positive sputum samples. The most common mutations associated with RMP and INH resistance were S531L and S315TL, respectively. A single rare mutation (C15T/A16G) was detected for INH resistance. The diagnostic performance of Genotype MTBDRplus VER 2.0 LPA in direct smear positive sputum sample was highly sensitive and specific for early detection of MDR-TB. However, the diagnostic performance of this molecular assay in direct smear negative sputum sample was low and showed a high level of invalid results for detection of M. tuberculosis and its resistance to RMP and/or INH so it is unlikely to implement Genotype MTBDRplus VER 2.0 for the detection of MDR-TB in direct smear negative sample in our routine settings. The sensitivity of the assay should be improved for detection of MDR-TB in direct smear negative sputum specimens.

  18. Blind I/Q imbalance and nonlinear ISI mitigation in Nyquist-SCM direct detection system with cascaded widely linear and Volterra equalizer

    NASA Astrophysics Data System (ADS)

    Liu, Na; Ju, Cheng

    2018-02-01

    Nyquist-SCM signal after fiber transmission, direct detection (DD), and analog down-conversion suffers from linear ISI, nonlinear ISI, and I/Q imbalance, simultaneously. Theoretical analysis based on widely linear (WL) and Volterra series is given to explain the relationship and interaction of these three interferences. A blind equalization algorithm, cascaded WL and Volterra equalizer, is designed to mitigate these three interferences. Furthermore, the feasibility of the proposed cascaded algorithm is experimentally demonstrated based on a 40-Gbps data rate 16-quadrature amplitude modulation (QAM) virtual single sideband (VSSB) Nyquist-SCM DD system over 100-km standard single mode fiber (SSMF) transmission. In addition, the performances of conventional strictly linear equalizer, WL equalizer, Volterra equalizer, and cascaded WL and Volterra equalizer are experimentally evaluated, respectively.

  19. Integration of FTTH and GI-POF in-house networks based on injection locking and direct-detection techniques.

    PubMed

    Peng, Hsiao-Chun; Lu, Hai-Han; Li, Chung-Yi; Su, Heng-Sheng; Hsu, Chin-Tai

    2011-03-28

    An integration of fiber-to-the-home (FTTH) and graded-index plastic optical fiber (GI-POF) in-house networks based on injection-locked vertical cavity surface emitting lasers (VCSELs) and direct-detection technique is proposed and experimentally demonstrated. Sufficient low bit error rate (BER) values were obtained over a combination of 20-km single-mode fiber (SMF) and 50-m GI-POF links. Signal qualities satisfy the worldwide interoperability for microwave access (WiMAX) requirement with data signals of 20 Mbps/5.8 GHz and 70 Mbps/10 GHz, respectively. Since our proposed network does not use sophisticated and expensive RF devices in premises, it reveals a prominent one with simpler and more economic advantages. Our proposed architecture is suitable for the SMF-based primary and GI-POF-based in-house networks.

  20. Using Muons to Image the Subsurface.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonal, Nedra; Cashion, Avery Ted; Cieslewski, Grzegorz

    Muons are subatomic particles that can penetrate the earth 's crust several kilometers and may be useful for subsurface characterization . The absorption rate of muons depends on the density of the materials through which they pass. Muons are more sensitive to density variation than other phenomena, including gravity, making them beneficial for subsurface investigation . Measurements of muon flux rate at differing directions provide density variations of the materials between the muon source (cosmic rays and neutrino interactions) and the detector, much like a CAT scan. Currently, muon tomography can resolve features to the sub-meter scale. This work consistsmore » of three parts to address the use of muons for subsurface characterization : 1) assess the use of muon scattering for estimating density differences of common rock types, 2 ) using muon flux to detect a void in rock, 3) measure muon direction by designing a new detector. Results from this project lay the groundwork for future directions in this field. Low-density objects can be detected by muons even when enclosed in high-density material like lead, and even small changes in density (e.g. changes due to fracturing of material) can be detected. Rock density has a linear relationship with muon scattering density per rock volume when this ratio is greater than 0.10 . Limitations on using muon scattering to assess density changes among common rock types have been identified. However, other analysis methods may show improved results for these relatively low density materials. Simulations show that muons can be used to image void space (e.g. tunnels) within rock but experimental results have been ambiguous. Improvements are suggested to improve imaging voids such as tunnels through rocks. Finally, a muon detector has been designed and tested to measure muon direction, which will improve signal-to-noise ratio and help address fundamental questions about the source of upgoing muons .« less

  1. Position and volume estimation of atmospheric nuclear detonations from video reconstruction

    NASA Astrophysics Data System (ADS)

    Schmitt, Daniel T.

    Recent work in digitizing films of foundational atmospheric nuclear detonations from the 1950s provides an opportunity to perform deeper analysis on these historical tests. This work leverages multi-view geometry and computer vision techniques to provide an automated means to perform three-dimensional analysis of the blasts for several points in time. The accomplishment of this requires careful alignment of the films in time, detection of features in the images, matching of features, and multi-view reconstruction. Sub-explosion features can be detected with a 67% hit rate and 22% false alarm rate. Hotspot features can be detected with a 71.95% hit rate, 86.03% precision and a 0.015% false positive rate. Detected hotspots are matched across 57-109 degree viewpoints with 76.63% average correct matching by defining their location relative to the center of the explosion, rotating them to the alternative viewpoint, and matching them collectively. When 3D reconstruction is applied to the hotspot matching it completes an automated process that has been used to create 168 3D point clouds with 31.6 points per reconstruction with each point having an accuracy of 0.62 meters with 0.35, 0.24, and 0.34 meters of accuracy in the x-, y- and z-direction respectively. As a demonstration of using the point clouds for analysis, volumes are estimated and shown to be consistent with radius-based models and in some cases improve on the level of uncertainty in the yield calculation.

  2. Long-Term Storage at -80°C: Effect on Rate of Recovery of Mycobacterium tuberculosis From Direct Acid-Fast Bacilli Smear-Positive Sputum Samples.

    PubMed

    Shinu, Pottathil; AshokKumar Singh, Varsha; Nair, Anroop; Farooq, Rumana; Ishaq, Sheikh

    2016-09-01

    The aim of this study was to evaluate the difference in the rate of recovery of Mycobacterium tuberculosis (MTB) from routinely cultured sputum and long-term stored sputum specimens (at -80°C) using Löwenstein-Jensen (LJ) media, Mycobacterium Growth Indicator Tube (BBL MGIT(TM) ), and Middlebrook 7H11 (MB 7H11) agar. Direct acid-fast bacilli smear-positive sputum specimens (both before and after storage [n = 136]) were studied (after culturing on LJ media, BBL MGIT(TM) , and MB 7H11 agar) and the performances were compared. For the detection of MTB, BBL MGIT(TM) and MB 7H11 agar (before storage) demonstrated a sensitivity, specificity, positive predictive value (PPV) of 98.28%, 30.77%, 92.68%, 66.67%, and negative predictive value (NPV) of 97.41%, 30.77%, 92.62%, 57.14%, respectively, when compared to LJ media (before storage). Similarly, BBL MGIT(TM) and MB 7H11 agar (after storage) demonstrated a sensitivity, specificity, PPV, and NPV of 95.5%, 38.89%, 90.6%, 58.33%, and 95.5%, 66.67 %, 94.64%, 70.59%, respectively, when compared to LJ media (after storage) for the detection of MTB. None of the culture techniques independently (both before and after storage) detected growth of MTB from all the sputum specimens studied. However, BBL MGIT(TM) system and LJ media combination (both before and after storage) effectively detected the growth of MTB from sputum specimens when compared to other culture technique combinations. © 2015 Wiley Periodicals, Inc.

  3. Broad spectrum infrared thermal desorption of wipe-based explosive and narcotic samples for trace mass spectrometric detection.

    PubMed

    Forbes, Thomas P; Staymates, Matthew; Sisco, Edward

    2017-08-07

    Wipe collected analytes were thermally desorbed using broad spectrum near infrared heating for mass spectrometric detection. Employing a twin tube filament-based infrared emitter, rapid and efficiently powered thermal desorption and detection of nanogram levels of explosives and narcotics was demonstrated. The infrared thermal desorption (IRTD) platform developed here used multi-mode heating (direct radiation and secondary conduction from substrate and subsequent convection from air) and a temperature ramp to efficiently desorb analytes with vapor pressures across eight orders of magnitude. The wipe substrate experienced heating rates up to (85 ± 2) °C s -1 with a time constant of (3.9 ± 0.2) s for 100% power emission. The detection of trace analytes was also demonstrated from complex mixtures, including plastic-bonded explosives and exogenous narcotics, explosives, and metabolites from collected artificial latent fingerprints. Manipulation of the emission power and duration directly controlled the heating rate and maximum temperature, enabling differential thermal desorption and a level of upstream separation for enhanced specificity. Transitioning from 100% power and 5 s emission duration to 25% power and 30 s emission enabled an order of magnitude increase in the temporal separation (single seconds to tens of seconds) of the desorption of volatile and semi-volatile species within a collected fingerprint. This mode of operation reduced local gas-phase concentrations, reducing matrix effects experienced with high concentration mixtures. IRTD provides a unique platform for the desorption of trace analytes from wipe collections, an area of importance to the security sector, transportation agencies, and customs and border protection.

  4. Direct detection of sub-GeV dark matter with scintillating targets

    DOE PAGES

    Derenzo, Stephen; Essig, Rouven; Massari, Andrea; ...

    2017-07-28

    We suggest a novel experimental concept for detecting MeV-to-GeV-mass dark matter, in which the dark matter scatters off electrons in a scintillating target and produces a signal of one or a few photons. New large-area photodetectors are needed to measure the photon signal with negligible dark counts, which could be constructed from transition edge sensor (TES) or microwave kinetic inductance detector (MKID) technology. Alternatively, detecting two photons in coincidence may allow the use of conventional photodetectors like photomultiplier tubes. Here we describe why scintillators may have distinct advantages over other experiments searching for a low ionization signal from sub-GeV darkmore » matter, as there are fewer potential sources of spurious backgrounds. We discuss various target choices, but focus on calculating the expected dark matter-electron scattering rates in three scintillating crystals: sodium iodide (NaI), cesium iodide (CsI), and gallium arsenide (GaAs). Among these, GaAs has the lowest band gap (1.52 eV) compared to NaI (5.9 eV) or CsI (6.4 eV), which in principle allows it to probe dark matter masses as low as ~0.5 MeV, compared to ~1.5 MeV with NaI or CsI. We compare these scattering rates with those expected in silicon (Si) and germanium (Ge). The proposed experimental concept presents an important complementary path to existing efforts, and its potential advantages may make it the most sensitive direct-detection probe of dark matter down to MeV masses.« less

  5. Direct detection of sub-GeV dark matter with scintillating targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Derenzo, Stephen; Essig, Rouven; Massari, Andrea

    We suggest a novel experimental concept for detecting MeV-to-GeV-mass dark matter, in which the dark matter scatters off electrons in a scintillating target and produces a signal of one or a few photons. New large-area photodetectors are needed to measure the photon signal with negligible dark counts, which could be constructed from transition edge sensor (TES) or microwave kinetic inductance detector (MKID) technology. Alternatively, detecting two photons in coincidence may allow the use of conventional photodetectors like photomultiplier tubes. Here we describe why scintillators may have distinct advantages over other experiments searching for a low ionization signal from sub-GeV darkmore » matter, as there are fewer potential sources of spurious backgrounds. We discuss various target choices, but focus on calculating the expected dark matter-electron scattering rates in three scintillating crystals: sodium iodide (NaI), cesium iodide (CsI), and gallium arsenide (GaAs). Among these, GaAs has the lowest band gap (1.52 eV) compared to NaI (5.9 eV) or CsI (6.4 eV), which in principle allows it to probe dark matter masses as low as ~0.5 MeV, compared to ~1.5 MeV with NaI or CsI. We compare these scattering rates with those expected in silicon (Si) and germanium (Ge). The proposed experimental concept presents an important complementary path to existing efforts, and its potential advantages may make it the most sensitive direct-detection probe of dark matter down to MeV masses.« less

  6. Decadal trends in marine reserves reveal differential rates of change in direct and indirect effects

    USGS Publications Warehouse

    Babcock, R.C.; Shears, N.T.; Alcala, A.C.; Barrett, N.S.; Edgar, G.J.; Lafferty, K.D.; McClanahan, T.R.; Russ, G.R.

    2010-01-01

    Decadal-scale observations of marine reserves suggest that indirect effects on taxa that occur through cascading trophic interactions take longer to develop than direct effects on target species. Combining and analyzing a unique set of long-term time series of ecologic data in and out of fisheries closures from disparate regions, we found that the time to initial detection of direct effects on target species (+ or -SE) was 5.13 + or - 1.9 years, whereas initial detection of indirect effects on other taxa, which were often trait mediated, took significantly longer (13.1 + or - 2.0 years). Most target species showed initial direct effects, but their trajectories over time were highly variable. Many target species continued to increase, some leveled off, and others decreased. Decreases were due to natural fluctuations, fishing impacts from outside reserves, or indirect effects from target species at higher trophic levels. The average duration of stable periods for direct effects was 6.2 + or - 1.2 years, even in studies of more than 15 years. For indirect effects, stable periods averaged 9.1 + or - 1.6 years, although this was not significantly different from direct effects. Populations of directly targeted species were more stable in reserves than in fished areas, suggesting increased ecologic resilience. This is an important benefit of marine reserves with respect to their function as a tool for conservation and restoration.

  7. Decadal trends in marine reserves reveal differential rates of change in direct and indirect effects.

    PubMed

    Babcock, R C; Shears, N T; Alcala, A C; Barrett, N S; Edgar, G J; Lafferty, K D; McClanahan, T R; Russ, G R

    2010-10-26

    Decadal-scale observations of marine reserves suggest that indirect effects on taxa that occur through cascading trophic interactions take longer to develop than direct effects on target species. Combining and analyzing a unique set of long-term time series of ecologic data in and out of fisheries closures from disparate regions, we found that the time to initial detection of direct effects on target species (±SE) was 5.13 ± 1.9 years, whereas initial detection of indirect effects on other taxa, which were often trait mediated, took significantly longer (13.1 ± 2.0 years). Most target species showed initial direct effects, but their trajectories over time were highly variable. Many target species continued to increase, some leveled off, and others decreased. Decreases were due to natural fluctuations, fishing impacts from outside reserves, or indirect effects from target species at higher trophic levels. The average duration of stable periods for direct effects was 6.2 ± 1.2 years, even in studies of more than 15 years. For indirect effects, stable periods averaged 9.1 ± 1.6 years, although this was not significantly different from direct effects. Populations of directly targeted species were more stable in reserves than in fished areas, suggesting increased ecologic resilience. This is an important benefit of marine reserves with respect to their function as a tool for conservation and restoration.

  8. Juvenile salmonid migratory behavior at the mouth of the Columbia River and within the plume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMichael, Geoffrey A.; O'Toole, Amanda C.; Harnish, Ryan A.

    A total of 8,159 acoustic-tagged salmonid smolts were detected at the mouth of the Columbia River. Of the fish detected at the mouth, 14% of yearling Chinook salmon, 9% of steelhead, and 22% of subyearling Chinook salmon were detected on a sparse array deployed in the Columbia River plume. Chinook salmon smolts decreased travel rate as they left the river and entered the plume, while steelhead increased travel rate. Chinook salmon also spent more time in the transitional area between the river mouth and plume as compared to steelhead. In early spring, yearling Chinook salmon and steelhead predominately migrated pastmore » the plume array towards the edge of the shelf and to the south. Later in the season, yearling Chinook salmon and steelhead smolts tended to migrate out of the river mouth in a northerly direction. Subyearling Chinook salmon migrated predominately past the portion of the plume array to the north of the river mouth.« less

  9. Host galaxy identification for binary black hole mergers with long baseline gravitational wave detectors

    NASA Astrophysics Data System (ADS)

    Howell, E. J.; Chan, M. L.; Chu, Q.; Jones, D. H.; Heng, I. S.; Lee, H.-M.; Blair, D.; Degallaix, J.; Regimbau, T.; Miao, H.; Zhao, C.; Hendry, M.; Coward, D.; Messenger, C.; Ju, L.; Zhu, Z.-H.

    2018-03-01

    The detection of black hole binary coalescence events by Advanced LIGO allows the science benefits of future detectors to be evaluated. In this paper, we report the science benefits of one or two 8 km arm length detectors based on the doubling of key parameters in an Advanced LIGO-type detector, combined with realizable enhancements. It is shown that the total detection rate for sources similar to those already detected would increase to ˜ 103-105 per year. Within 0.4 Gpc, we find that around 10 of these events would be localizable to within ˜10-1 deg2. This is sufficient to make unique associations or to rule out a direct association with the brightest galaxies in optical surveys (at r-band magnitudes of 17 or above) or for deeper limits (down to r-band magnitudes of 20) yield statistically significant associations. The combination of angular resolution and event rate would benefit precision testing of formation models, cosmic evolution, and cosmological studies.

  10. Detection of Rooftop Cooling Unit Faults Based on Electrical Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armstrong, Peter R.; Laughman, C R.; Leeb, S B.

    Non-intrusive load monitoring (NILM) is accomplished by sampling voltage and current at high rates and reducing the resulting start transients or harmonic contents to concise ''signatures''. Changes in these signatures can be used to detect, and in many cases directly diagnose, equipment and component faults associated with roof-top cooling units. Use of the NILM for fault detection and diagnosis (FDD) is important because (1) it complements other FDD schemes that are based on thermo-fluid sensors and analyses and (2) it is minimally intrusive (one measuring point in the relatively protected confines of the control panel) and therefore inherently reliable. Thismore » paper describes changes in the power signatures of fans and compressors that were found, experimentally and theoretically, to be useful for fault detection.« less

  11. Seismic detection and analysis of icequakes at Columbia Glacier, Alaska

    USGS Publications Warehouse

    O'Neel, Shad; Marshall, Hans P.; McNamara, Daniel E.; Pfeffer, William Tad

    2007-01-01

    Contributions to sea level rise from rapidly retreating marine-terminating glaciers are large and increasing. Strong increases in iceberg calving occur during retreat, which allows mass transfer to the ocean at a much higher rate than possible through surface melt alone. To study this process, we deployed an 11-sensor passive seismic network at Columbia Glacier, Alaska, during 2004–2005. We show that calving events generate narrow-band seismic signals, allowing frequency domain detections. Detection parameters were determined using direct observations of calving and validated using three statistical methods and hypocenter locations. The 1–3 Hz detections provide a good measure of the temporal distribution and size of calving events. Possible source mechanisms for the unique waveforms are discussed, and we analyze potential forcings for the observed seismicity.

  12. Estimation of Locomotion States of a Rat by Neural Signals from the Motor Cortices Based on a Linear Correlation Model

    NASA Astrophysics Data System (ADS)

    Fukayama, Osamu; Taniguchi, Noriyuki; Suzuki, Takafumi; Mabuchi, Kunihiko

    We are developing a brain-machine interface (BMI) called “RatCar," a small vehicle controlled by the neural signals of a rat's brain. An unconfined adult rat with a set of bundled neural electrodes in the brain rides on the vehicle. Each bundle consists of four tungsten wires isolated with parylene polymer. These bundles were implanted in the primary motor and premotor cortices in both hemispheres of the brain. In this paper, methods and results for estimating locomotion speed and directional changes are described. Neural signals were recorded as the rat moved in a straight line and as it changed direction in a curve. Spike-like waveforms were then detected and classified into several clusters to calculate a firing rate for each neuron. The actual locomotion velocity and directional changes of the rat were recorded concurrently. Finally, the locomotion states were correlated with the neural firing rates using a simple linear model. As a result, the abstract estimation of the locomotion velocity and directional changes were achieved.

  13. Network models of frequency modulated sweep detection.

    PubMed

    Skorheim, Steven; Razak, Khaleel; Bazhenov, Maxim

    2014-01-01

    Frequency modulated (FM) sweeps are common in species-specific vocalizations, including human speech. Auditory neurons selective for the direction and rate of frequency change in FM sweeps are present across species, but the synaptic mechanisms underlying such selectivity are only beginning to be understood. Even less is known about mechanisms of experience-dependent changes in FM sweep selectivity. We present three network models of synaptic mechanisms of FM sweep direction and rate selectivity that explains experimental data: (1) The 'facilitation' model contains frequency selective cells operating as coincidence detectors, summing up multiple excitatory inputs with different time delays. (2) The 'duration tuned' model depends on interactions between delayed excitation and early inhibition. The strength of delayed excitation determines the preferred duration. Inhibitory rebound can reinforce the delayed excitation. (3) The 'inhibitory sideband' model uses frequency selective inputs to a network of excitatory and inhibitory cells. The strength and asymmetry of these connections results in neurons responsive to sweeps in a single direction of sufficient sweep rate. Variations of these properties, can explain the diversity of rate-dependent direction selectivity seen across species. We show that the inhibitory sideband model can be trained using spike timing dependent plasticity (STDP) to develop direction selectivity from a non-selective network. These models provide a means to compare the proposed synaptic and spectrotemporal mechanisms of FM sweep processing and can be utilized to explore cellular mechanisms underlying experience- or training-dependent changes in spectrotemporal processing across animal models. Given the analogy between FM sweeps and visual motion, these models can serve a broader function in studying stimulus movement across sensory epithelia.

  14. The direct assignment option as a modular design component: an example for the setting of two predefined subgroups.

    PubMed

    An, Ming-Wen; Lu, Xin; Sargent, Daniel J; Mandrekar, Sumithra J

    2015-01-01

    A phase II design with an option for direct assignment (stop randomization and assign all patients to experimental treatment based on interim analysis, IA) for a predefined subgroup was previously proposed. Here, we illustrate the modularity of the direct assignment option by applying it to the setting of two predefined subgroups and testing for separate subgroup main effects. We power the 2-subgroup direct assignment option design with 1 IA (DAD-1) to test for separate subgroup main effects, with assessment of power to detect an interaction in a post-hoc test. Simulations assessed the statistical properties of this design compared to the 2-subgroup balanced randomized design with 1 IA, BRD-1. Different response rates for treatment/control in subgroup 1 (0.4/0.2) and in subgroup 2 (0.1/0.2, 0.4/0.2) were considered. The 2-subgroup DAD-1 preserves power and type I error rate compared to the 2-subgroup BRD-1, while exhibiting reasonable power in a post-hoc test for interaction. The direct assignment option is a flexible design component that can be incorporated into broader design frameworks, while maintaining desirable statistical properties, clinical appeal, and logistical simplicity.

  15. First measurement of pp neutrinos in real time in the Borexino detector

    NASA Astrophysics Data System (ADS)

    Mosteiro, Pablo

    2014-09-01

    The Sun is fueled by a series of nuclear reactions that produce the energy that makes it shine. Neutrinos (nu) produced by these nuclear reactions exit the Sun and reach Earth within minutes, providing us with key information about what goes on at the core of our star. For over twenty years since the first detection of solar neutrinos in the late 1960's, an apparent deficit in their detection rate was known as the Solar Neutrino Problem. Today, the Mikheyev-Smirnov-Wolfenstein (MSW) effect is the accepted mechanism by which neutrinos oscillate inside the Sun, arriving at Earth as a mixture of nue, numu and nutau, the latter two of which were invisible to early detectors. Several experiments have now confirmed the observation of neutrino oscillations. These experiments, when their results are combined together, have demonstrated that neutrino oscillations are well described by the Large Mixing Angle (LMA) solution of the MSW effect. This thesis presents the first measurement of pp neutrinos in the Borexino detector, which is another validation of the LMA-MSW model of neutrino oscillations. In addition, it is one more step towards the completion of the spectroscopy of pp chain neutrinos in Borexino, leaving only the extremely faint hep neutrinos undetected. This advance validates the experiment itself and its previous results. This is, furthermore, the first direct real-time measurement of pp neutrinos. We find a pp neutrino detection rate of 143+/-16 (stat)+/-10 (syst) cpd/100 t in the Borexino experiment, which translates, according to the LMA-MSW model, to (6.42+/-0.85)x1010 cm -2 s-1. We also report on a measurement of neutrons in a dedicated system within the Borexino detector, which resulted in an improved understanding of neutron rates in liquid scintillator detectors at Gran Sasso depths. This result is crucial to the development of novel direct dark matter detection experiments.

  16. Sensitivity to change and concurrent validity of direct behavior ratings for academic anxiety.

    PubMed

    von der Embse, Nathaniel P; Scott, Emma-Catherine; Kilgus, Stephen P

    2015-06-01

    Multitiered frameworks of service delivery have traditionally underserved students with mental health needs. Whereas research has supported the assessment and intervention of social and academic behavior across tiers, evidence is limited with regard to mental health concerns including internalizing behaviors (e.g., anxiety and depression). In particular, there is a notable shortage of brief anxiety assessment tools to be used for progress monitoring purposes. Moreover, traditional omnibus rating scale approaches may fail to capture contextually dependent anxiety. The purpose of the present investigation is to examine the sensitivity to change and concurrent validity of Direct Behavior Ratings (DBR; Chafouleas, Riley-Tillman, & Christ, 2009; Chafouleas, Riley-Tillman, & Sugai, 2007) of anxiety and traditional rating scales in measuring academic anxiety directly before, during, and after a potentially anxiety provoking stimulus. Research was conducted with 115 undergraduate students in a Southeastern university. Results indicated significant relationships between DBRs and pre- and postmeasures of anxiety. Change metrics suggested an overall lack of correspondence between DBR and the criterion measure, with DBR scales detecting greater change both across the testing situation and participants. The use of DBR for anxiety is considered within a multitiered, problem-solving framework. Feasibility and limitations associated with implementation are discussed. (c) 2015 APA, all rights reserved).

  17. Optical communication for space missions

    NASA Technical Reports Server (NTRS)

    Firtmaurice, M.

    1991-01-01

    Activities performed at NASA/GSFC (Goddard Space Flight Center) related to direct detection optical communications for space applications are discussed. The following subject areas are covered: (1) requirements for optical communication systems (data rates and channel quality; spatial acquisition; fine tracking and pointing; and transmit point-ahead correction); (2) component testing and development (laser diodes performance characterization and life testing; and laser diode power combining); (3) system development and simulations (The GSFC pointing, acquisition and tracking system; hardware description; preliminary performance analysis; and high data rate transmitter/receiver systems); and (4) proposed flight demonstration of optical communications.

  18. Effect of disordered hemes and dimerization in isolated a-subunits of hemoglobin detected by time-resolved fluorescence spectroscopy in the picosecond range

    NASA Astrophysics Data System (ADS)

    Gryczynski, Zygmunt; Fronticelli, Clara; Gratton, Enrico; Lubkowski, Jacek; Bucci, Enrico

    1994-08-01

    Our recent linear dichroism study of transition moment directions for protoporphyrin derivatives [1,2] demonstrate that heme cannot be considered a planar oscillator when it acts as an acceptor of radiationless excitation energy transfer from tryptophan. The linear nature of the heme absorption transition moment implies a strong dependence of the transfer rate factors on the relative angular position of the heme and tryptophan, i.e. on the k2 orientation parameter of the Forster equation. Using the atomic coordinates of human hemoglobin and taking into account the direction of the transition moment of the near UV (300-380 nm) heme absorption band we have estimated the rate of energy transfer from tryptophan to heme in the isolated a chains, which are a single tryptophan protein. It appears that the rate of energy transfer is very sensitive to the orientation of the transition moment of the heme and similarly to myoglobin [3] natural heme disorder significantly reduces the transfer efficiency in isolated a subunits. On this basis we were able to predict very accurately the two lifetimes detectable in the systems, of 32 and 1050 ps respectively, where the amplitude of the longer lifetime is very consistent with the amount of disordered hemes found by La Mar [4,5] for the a subunits of hemoglobin.

  19. Characterizing the roles of changing population size and selection on the evolution of flux control in metabolic pathways.

    PubMed

    Orlenko, Alena; Chi, Peter B; Liberles, David A

    2017-05-25

    Understanding the genotype-phenotype map is fundamental to our understanding of genomes. Genes do not function independently, but rather as part of networks or pathways. In the case of metabolic pathways, flux through the pathway is an important next layer of biological organization up from the individual gene or protein. Flux control in metabolic pathways, reflecting the importance of mutation to individual enzyme genes, may be evolutionarily variable due to the role of mutation-selection-drift balance. The evolutionary stability of rate limiting steps and the patterns of inter-molecular co-evolution were evaluated in a simulated pathway with a system out of equilibrium due to fluctuating selection, population size, or positive directional selection, to contrast with those under stabilizing selection. Depending upon the underlying population genetic regime, fluctuating population size was found to increase the evolutionary stability of rate limiting steps in some scenarios. This result was linked to patterns of local adaptation of the population. Further, during positive directional selection, as with more complex mutational scenarios, an increase in the observation of inter-molecular co-evolution was observed. Differences in patterns of evolution when systems are in and out of equilibrium, including during positive directional selection may lead to predictable differences in observed patterns for divergent evolutionary scenarios. In particular, this result might be harnessed to detect differences between compensatory processes and directional processes at the pathway level based upon evolutionary observations in individual proteins. Detecting functional shifts in pathways reflects an important milestone in predicting when changes in genotypes result in changes in phenotypes.

  20. Yersinia enterocolitica in slaughter pig tonsils: enumeration and detection by enrichment versus direct plating culture.

    PubMed

    Van Damme, Inge; Habib, Ihab; De Zutter, Lieven

    2010-02-01

    Tonsil samples from 139 slaughter pigs were examined for the presence of pathogenic Yersinia enterocolitica by enrichment procedures based on the standard method ISO 10273:2003. In addition, samples were tested by direct plating method to evaluate its efficiency compared to the enrichment culture methods and to quantify the level of contamination in porcine tonsils. In total, 52 samples (37.4%) were positive for pathogenic Y. enterocolitica, all belonging to bioserotype 4/O:3. Fifty out of the 52 positive samples (96.2%) were detected by direct plating. Enumeration showed an average concentration of 4.5 log(10) CFU g(-1) and 4.4 log(10) CFU g(-1) tonsil on Salmonella-Shigella-desoxycholate-calcium chloride (SSDC) and cefsulodin-irgasan-novobiocin (CIN) agar plates, respectively. The enrichment procedures recommended by the ISO 10273:2003 method were not optimal for the isolation of pathogenic Y. enterocolitica from pig tonsils: two days enrichment in irgasan-ticarcillin-potassium chlorate (ITC) broth resulted in an isolation rate of 84.6%, while 5 days enrichment in peptone-sorbitol-bile (PSB) broth recovered only 59.6% of positive samples. Reducing the enrichment time in PSB from 5 to 2 days resulted in a significantly higher recovery rate (94.2%) and might serve as an appropriate enrichment protocol for the isolation of pathogenic Y. enterocolitica from pig tonsils. Compared to enrichment culture methods, results based on direct plating can be obtained in a shorter time course and provide quantitative data that might be needed for further risk assessment studies.

  1. Performance evaluation of the HepB Typer-Entecavir kit for detection of entecavir resistance mutations in chronic hepatitis B

    PubMed Central

    Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Han, Kwang-Hyub

    2013-01-01

    Background/Aims Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. Methods The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Results Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. Conclusions The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B. PMID:24459645

  2. Rate constant for OH with selected large alkanes : shock-tube measurements and an improved group scheme.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivaramakrishnan, R.; Michael, J. V.; Chemical Sciences and Engineering Division

    High-temperature rate constant experiments on OH with the five large (C{sub 5}-C{sub 8}) saturated hydrocarbons n-heptane, 2,2,3,3-tetramethylbutane (2,2,3,3-TMB), n-pentane, n-hexane, and 2,3-dimethylbutane (2,3-DMB) were performed with the reflected-shock-tube technique using multipass absorption spectrometric detection of OH radicals at 308 nm. Single-point determinations at {approx}1200 K on n-heptane, 2,2,3,3-TMB, n-hexane, and 2,3-DMB were previously reported by Cohen and co-workers; however, the present work substantially extends the database to both lower and higher temperature. The present experiments span a wide temperature range, 789-1308 K, and represent the first direct measurements of rate constants at T > 800 K for n-pentane. The presentmore » work utilized 48 optical passes corresponding to a total path length of {approx}4.2 m. As a result of this increased path length, the high OH concentration detection sensitivity permitted pseudo-first-order analyses for unambiguously measuring rate constants.« less

  3. Colluvial legacies of millennial landscape change on individual hillsides, place-based investigation in the western Pyrenees Mountains

    Treesearch

    D.S. Leigh; T.L. Gragson; M.R. Coughlan

    2015-01-01

    We detect transition to agropastoral land use in a mountain landscape by radiocarbon dating physical signatures (sedimentation rates, charcoal concentrations, magnetic susceptibility) of conversion from native forest to pasture contained within colluvial stratigraphic sections. Focus is on two study sites located on toeslopes directly beneath zero-order hollows...

  4. Survey of pickup ion signatures in the vicinity of Titan using CAPS/IMS

    NASA Astrophysics Data System (ADS)

    Regoli, L. H.; Coates, A. J.; Thomsen, M. F.; Jones, G. H.; Roussos, E.; Waite, J. H.; Krupp, N.; Cox, G.

    2016-09-01

    Pickup ion detection at Titan is challenging because ion cyclotron waves are rarely detected in the vicinity of the moon. In this work, signatures left by freshly produced pickup heavy ions (m/q ˜ 16 to m/q ˜ 28) as detected in the plasma data by the Cassini Plasma Spectrometer/Ion Mass Spectrometer (CAPS/IMS) instrument on board Cassini are analyzed. In order to discern whether these correspond to ions of exospheric origin, one of the flybys during which the reported signatures were observed is investigated in detail. For this purpose, ion composition data from time-of-flight measurements and test particle simulations to constrain the ions' origin are used. After being validated, the detection method is applied to all the flybys for which the CAPS/IMS instrument gathered valid data, constraining the region around the moon where the signatures are observed. The results reveal an escape region located in the anti-Saturn direction as expected from the nominal corotation electric field direction. These findings provide new constraints for the area of freshly produced pickup ion escape, giving an approximate escape rate of 3.3-2+3×1023 ions· s-1.

  5. Airport testing an explosives detection portal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhykerd, C.; Linker, K.; Hannum, D.

    1998-08-01

    At the direction of the US Congress, following the Pan Am 103 and TWA 800 crashes, the Federal Aviation Administration funded development of non-invasive techniques to screen airline passengers for explosives. Such an explosives detection portal, developed at Sandia National Laboratories, was field tested at the Albuquerque International airport in September 1997. During the 2-week field trial, 2,400 passengers were screened and 500 surveyed. Throughput, reliability, maintenance and sensitivity were studied. Follow-up testing at Sandia and at Idaho National Engineering and Environmental Laboratory was conducted. A passenger stands in the portal for five seconds while overhead fans blow air overmore » his body. Any explosive vapors or dislodged particles are collected in vents at the feet. Explosives are removed from the air in a preconcentrator and subsequently directed into an ion mobility spectrometer for detection. Throughput measured 300 passengers per hour. The non-invasive portal can detect subfingerprint levels of explosives residue on clothing. A survey of 500 passengers showed a 97% approval rating, with 99% stating that such portals, if effective, should be installed in airports to improve security. Results of the airport test, as well as operational issues, are discussed.« less

  6. WGM-Based Photonic Local Oscillators and Modulators

    NASA Technical Reports Server (NTRS)

    Matsko, Andrey; Maleki, Lute; Iltchenko, Vladimir; Savchenkov, Anatoliy

    2007-01-01

    Photonic local oscillators and modulators that include whispering-gallery mode (WGM) optical resonators have been proposed as power-efficient devices for generating and detecting radiation at frequencies of the order of a terahertz. These devices are intended especially to satisfy anticipated needs for receivers capable of detecting lowpower, narrow-band terahertz signals to be used for sensing substances of interest in scientific and military applications. At present, available terahertz-signal detectors are power-inefficient and do not afford the spectral and amplitude resolution needed for detecting such signals. The proposed devices would not be designed according to the conventional approach of direct detection of terahertz radiation. Instead, terahertz radiation would first be up-converted into the optical domain, wherein signals could be processed efficiently by photonic means and detected by optical photodetectors, which are more efficient than are photodetectors used in conventional direct detection of terahertz radiation. The photonic devices used to effect the up-conversion would include a tunable optical local oscillator and a novel electro-optical modulator. A local oscillator according to the proposal would be a WGM-based modelocked laser operating at a desired pulserepetition rate of the order of a terahertz. The oscillator would include a terahertz optical filter based on a WGM microresonator, a fiber-optic delay line, an optical amplifier (which could be either a semiconductor optical amplifier or an erbium-doped optical fiberamplifier), and a WGM Ka-band modulator. The terahertz repetition rate would be obtained through harmonic mode locking: for example, by modulating the light at a frequency of 33 GHz and locking each 33d optical mode, one would create a 1.089-THz pulse train. The high resonance quality factors (Q values) of WGM optical resonators should make it possible to decrease signal-generation threshold power levels significantly below those of other optical-signal-generation devices.

  7. Linear feature detection algorithm for astronomical surveys - I. Algorithm description

    NASA Astrophysics Data System (ADS)

    Bektešević, Dino; Vinković, Dejan

    2017-11-01

    Computer vision algorithms are powerful tools in astronomical image analyses, especially when automation of object detection and extraction is required. Modern object detection algorithms in astronomy are oriented towards detection of stars and galaxies, ignoring completely the detection of existing linear features. With the emergence of wide-field sky surveys, linear features attract scientific interest as possible trails of fast flybys of near-Earth asteroids and meteors. In this work, we describe a new linear feature detection algorithm designed specifically for implementation in big data astronomy. The algorithm combines a series of algorithmic steps that first remove other objects (stars and galaxies) from the image and then enhance the line to enable more efficient line detection with the Hough algorithm. The rate of false positives is greatly reduced thanks to a step that replaces possible line segments with rectangles and then compares lines fitted to the rectangles with the lines obtained directly from the image. The speed of the algorithm and its applicability in astronomical surveys are also discussed.

  8. Detection of maize kernels breakage rate based on K-means clustering

    NASA Astrophysics Data System (ADS)

    Yang, Liang; Wang, Zhuo; Gao, Lei; Bai, Xiaoping

    2017-04-01

    In order to optimize the recognition accuracy of maize kernels breakage detection and improve the detection efficiency of maize kernels breakage, this paper using computer vision technology and detecting of the maize kernels breakage based on K-means clustering algorithm. First, the collected RGB images are converted into Lab images, then the original images clarity evaluation are evaluated by the energy function of Sobel 8 gradient. Finally, the detection of maize kernels breakage using different pixel acquisition equipments and different shooting angles. In this paper, the broken maize kernels are identified by the color difference between integrity kernels and broken kernels. The original images clarity evaluation and different shooting angles are taken to verify that the clarity and shooting angles of the images have a direct influence on the feature extraction. The results show that K-means clustering algorithm can distinguish the broken maize kernels effectively.

  9. Of Detection Limits and Effective Mitigation: The Use of Infrared Cameras for Methane Leak Detection

    NASA Astrophysics Data System (ADS)

    Ravikumar, A. P.; Wang, J.; McGuire, M.; Bell, C.; Brandt, A. R.

    2017-12-01

    Mitigating methane emissions, a short-lived and potent greenhouse gas, is critical to limiting global temperature rise to two degree Celsius as outlined in the Paris Agreement. A major source of anthropogenic methane emissions in the United States is the oil and gas sector. To this effect, state and federal governments have recommended the use of optical gas imaging systems in periodic leak detection and repair (LDAR) surveys to detect for fugitive emissions or leaks. The most commonly used optical gas imaging systems (OGI) are infrared cameras. In this work, we systematically evaluate the limits of infrared (IR) camera based OGI system for use in methane leak detection programs. We analyze the effect of various parameters that influence the minimum detectable leak rates of infrared cameras. Blind leak detection tests were carried out at the Department of Energy's MONITOR natural gas test-facility in Fort Collins, CO. Leak sources included natural gas wellheads, separators, and tanks. With an EPA mandated 60 g/hr leak detection threshold for IR cameras, we test leak rates ranging from 4 g/hr to over 350 g/hr at imaging distances between 5 ft and 70 ft from the leak source. We perform these experiments over the course of a week, encompassing a wide range of wind and weather conditions. Using repeated measurements at a given leak rate and imaging distance, we generate detection probability curves as a function of leak-size for various imaging distances, and measurement conditions. In addition, we estimate the median detection threshold - leak-size at which the probability of detection is 50% - under various scenarios to reduce uncertainty in mitigation effectiveness. Preliminary analysis shows that the median detection threshold varies from 3 g/hr at an imaging distance of 5 ft to over 150 g/hr at 50 ft (ambient temperature: 80 F, winds < 4 m/s). Results from this study can be directly used to improve OGI based LDAR protocols and reduce uncertainty in estimated mitigation effectiveness. Furthermore, detection limits determined in this study can be used as standards to compare new detection technologies.

  10. Assessing alternatives for directional detection of a halo of weakly interacting massive particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Copi, Craig J.; Krauss, Lawrence M.; Department of Astronomy, Case Western Reserve University, 10900 Euclid Ave., Cleveland, Ohio 44106-7079

    2007-01-15

    The future of direct terrestrial WIMP detection lies on two fronts: new, much larger low background detectors sensitive to energy deposition, and detectors with directional sensitivity. The former can explore a large range of WIMP parameter space using well-tested technology while the latter may be necessary if one is to disentangle particle physics parameters from astrophysical halo parameters. Because directional detectors will be quite difficult to construct it is worthwhile exploring in advance generally which experimental features will yield the greatest benefits at the lowest costs. We examine the sensitivity of directional detectors with varying angular tracking resolution with andmore » without the ability to distinguish forward versus backward recoils, and compare these to the sensitivity of a detector where the track is projected onto a two-dimensional plane. The latter detector regardless of where it is placed on the Earth, can be oriented to produce a significantly better discrimination signal than a 3D detector without this capability, and with sensitivity within a factor of 2 of a full 3D tracking detector. Required event rates to distinguish signals from backgrounds for a simple isothermal halo range from the low teens in the best case to many thousands in the worst.« less

  11. Principal Components Analysis of Triaxial Vibration Data From Helicopter Transmissions

    NASA Technical Reports Server (NTRS)

    Tumer, Irem Y.; Huff, Edward M.

    2001-01-01

    Research on the nature of the vibration data collected from helicopter transmissions during flight experiments has led to several crucial observations believed to be responsible for the high rates of false alarms and missed detections in aircraft vibration monitoring systems. This work focuses on one such finding, namely, the need to consider additional sources of information about system vibrations. In this light, helicopter transmission vibration data, collected using triaxial accelerometers, were explored in three different directions, analyzed for content, and then combined using Principal Components Analysis (PCA) to analyze changes in directionality. In this paper, the PCA transformation is applied to 176 test conditions/data sets collected from an OH58C helicopter to derive the overall experiment-wide covariance matrix and its principal eigenvectors. The experiment-wide eigenvectors. are then projected onto the individual test conditions to evaluate changes and similarities in their directionality based on the various experimental factors. The paper will present the foundations of the proposed approach, addressing the question of whether experiment-wide eigenvectors accurately model the vibration modes in individual test conditions. The results will further determine the value of using directionality and triaxial accelerometers for vibration monitoring and anomaly detection.

  12. Genetics of Genome-Wide Recombination Rate Evolution in Mice from an Isolated Island.

    PubMed

    Wang, Richard J; Payseur, Bret A

    2017-08-01

    Recombination rate is a heritable quantitative trait that evolves despite the fundamentally conserved role that recombination plays in meiosis. Differences in recombination rate can alter the landscape of the genome and the genetic diversity of populations. Yet our understanding of the genetic basis of recombination rate evolution in nature remains limited. We used wild house mice ( Mus musculus domesticus ) from Gough Island (GI), which diverged recently from their mainland counterparts, to characterize the genetics of recombination rate evolution. We quantified genome-wide autosomal recombination rates by immunofluorescence cytology in spermatocytes from 240 F 2 males generated from intercrosses between GI-derived mice and the wild-derived inbred strain WSB/EiJ. We identified four quantitative trait loci (QTL) responsible for inter-F 2 variation in this trait, the strongest of which had effects that opposed the direction of the parental trait differences. Candidate genes and mutations for these QTL were identified by overlapping the detected intervals with whole-genome sequencing data and publicly available transcriptomic profiles from spermatocytes. Combined with existing studies, our findings suggest that genome-wide recombination rate divergence is not directional and its evolution within and between subspecies proceeds from distinct genetic loci. Copyright © 2017 by the Genetics Society of America.

  13. Supervised machine learning on a network scale: application to seismic event classification and detection

    NASA Astrophysics Data System (ADS)

    Reynen, Andrew; Audet, Pascal

    2017-09-01

    A new method using a machine learning technique is applied to event classification and detection at seismic networks. This method is applicable to a variety of network sizes and settings. The algorithm makes use of a small catalogue of known observations across the entire network. Two attributes, the polarization and frequency content, are used as input to regression. These attributes are extracted at predicted arrival times for P and S waves using only an approximate velocity model, as attributes are calculated over large time spans. This method of waveform characterization is shown to be able to distinguish between blasts and earthquakes with 99 per cent accuracy using a network of 13 stations located in Southern California. The combination of machine learning with generalized waveform features is further applied to event detection in Oklahoma, United States. The event detection algorithm makes use of a pair of unique seismic phases to locate events, with a precision directly related to the sampling rate of the generalized waveform features. Over a week of data from 30 stations in Oklahoma, United States are used to automatically detect 25 times more events than the catalogue of the local geological survey, with a false detection rate of less than 2 per cent. This method provides a highly confident way of detecting and locating events. Furthermore, a large number of seismic events can be automatically detected with low false alarm, allowing for a larger automatic event catalogue with a high degree of trust.

  14. A chest-shape target automatic detection method based on Deformable Part Models

    NASA Astrophysics Data System (ADS)

    Zhang, Mo; Jin, Weiqi; Li, Li

    2016-10-01

    Automatic weapon platform is one of the important research directions at domestic and overseas, it needs to accomplish fast searching for the object to be shot under complex background. Therefore, fast detection for given target is the foundation of further task. Considering that chest-shape target is common target of shoot practice, this paper treats chestshape target as the target and studies target automatic detection method based on Deformable Part Models. The algorithm computes Histograms of Oriented Gradient(HOG) features of the target and trains a model using Latent variable Support Vector Machine(SVM); In this model, target image is divided into several parts then we can obtain foot filter and part filters; Finally, the algorithm detects the target at the HOG features pyramid with method of sliding window. The running time of extracting HOG pyramid with lookup table can be shorten by 36%. The result indicates that this algorithm can detect the chest-shape target in natural environments indoors or outdoors. The true positive rate of detection reaches 76% with many hard samples, and the false positive rate approaches 0. Running on a PC (Intel(R)Core(TM) i5-4200H CPU) with C++ language, the detection time of images with the resolution of 640 × 480 is 2.093s. According to TI company run library about image pyramid and convolution for DM642 and other hardware, our detection algorithm is expected to be implemented on hardware platform, and it has application prospect in actual system.

  15. Hawk Eyes II: Diurnal Raptors Differ in Head Movement Strategies When Scanning from Perches

    PubMed Central

    O'Rourke, Colleen T.; Pitlik, Todd; Hoover, Melissa; Fernández-Juricic, Esteban

    2010-01-01

    Background Relatively little is known about the degree of inter-specific variability in visual scanning strategies in species with laterally placed eyes (e.g., birds). This is relevant because many species detect prey while perching; therefore, head movement behavior may be an indicator of prey detection rate, a central parameter in foraging models. We studied head movement strategies in three diurnal raptors belonging to the Accipitridae and Falconidae families. Methodology/Principal Findings We used behavioral recording of individuals under field and captive conditions to calculate the rate of two types of head movements and the interval between consecutive head movements. Cooper's Hawks had the highest rate of regular head movements, which can facilitate tracking prey items in the visually cluttered environment they inhabit (e.g., forested habitats). On the other hand, Red-tailed Hawks showed long intervals between consecutive head movements, which is consistent with prey searching in less visually obstructed environments (e.g., open habitats) and with detecting prey movement from a distance with their central foveae. Finally, American Kestrels have the highest rates of translational head movements (vertical or frontal displacements of the head keeping the bill in the same direction), which have been associated with depth perception through motion parallax. Higher translational head movement rates may be a strategy to compensate for the reduced degree of eye movement of this species. Conclusions Cooper's Hawks, Red-tailed Hawks, and American Kestrels use both regular and translational head movements, but to different extents. We conclude that these diurnal raptors have species-specific strategies to gather visual information while perching. These strategies may optimize prey search and detection with different visual systems in habitat types with different degrees of visual obstruction. PMID:20877650

  16. Hawk eyes II: diurnal raptors differ in head movement strategies when scanning from perches.

    PubMed

    O'Rourke, Colleen T; Pitlik, Todd; Hoover, Melissa; Fernández-Juricic, Esteban

    2010-09-22

    Relatively little is known about the degree of inter-specific variability in visual scanning strategies in species with laterally placed eyes (e.g., birds). This is relevant because many species detect prey while perching; therefore, head movement behavior may be an indicator of prey detection rate, a central parameter in foraging models. We studied head movement strategies in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used behavioral recording of individuals under field and captive conditions to calculate the rate of two types of head movements and the interval between consecutive head movements. Cooper's Hawks had the highest rate of regular head movements, which can facilitate tracking prey items in the visually cluttered environment they inhabit (e.g., forested habitats). On the other hand, Red-tailed Hawks showed long intervals between consecutive head movements, which is consistent with prey searching in less visually obstructed environments (e.g., open habitats) and with detecting prey movement from a distance with their central foveae. Finally, American Kestrels have the highest rates of translational head movements (vertical or frontal displacements of the head keeping the bill in the same direction), which have been associated with depth perception through motion parallax. Higher translational head movement rates may be a strategy to compensate for the reduced degree of eye movement of this species. Cooper's Hawks, Red-tailed Hawks, and American Kestrels use both regular and translational head movements, but to different extents. We conclude that these diurnal raptors have species-specific strategies to gather visual information while perching. These strategies may optimize prey search and detection with different visual systems in habitat types with different degrees of visual obstruction.

  17. Periprosthetic Infection following Primary Hip and Knee Arthroplasty: The Impact of Limiting the Postoperative Surveillance Period.

    PubMed

    Roth, Virginia R; Mitchell, Robyn; Vachon, Julie; Alexandre, Stéphanie; Amaratunga, Kanchana; Smith, Stephanie; Vearncombe, Mary; Davis, Ian; Mertz, Dominik; Henderson, Elizabeth; John, Michael; Johnston, Lynn; Lemieux, Camille; Pelude, Linda; Gravel, Denise

    2017-02-01

    BACKGROUND Hip and knee arthroplasty infections are associated with considerable healthcare costs. The merits of reducing the postoperative surveillance period from 1 year to 90 days have been debated. OBJECTIVES To report the first pan-Canadian hip and knee periprosthetic joint infection (PJI) rates and to describe the implications of a shorter (90-day) postoperative surveillance period. METHODS Prospective surveillance for infection following hip and knee arthroplasty was conducted by hospitals participating in the Canadian Nosocomial Infection Surveillance Program (CNISP) using standard surveillance definitions. RESULTS Overall hip and knee PJI rates were 1.64 and 1.52 per 100 procedures, respectively. Deep incisional and organ-space hip and knee PJI rates were 0.96 and 0.71, respectively. In total, 93% of hip PJIs and 92% of knee PJIs were identified within 90 days, with a median time to detection of 21 days. However, 11%-16% of deep incisional and organ-space infections were not detected within 90 days. This rate was reduced to 3%-4% at 180 days post procedure. Anaerobic and polymicrobial infections had the shortest median time from procedure to detection (17 and 18 days, respectively) compared with infections due to other microorganisms, including Staphylococcus aureus. CONCLUSIONS PJI rates were similar to those reported elsewhere, although differences in national surveillance systems limit direct comparisons. Our results suggest that a postoperative surveillance period of 90 days will detect the majority of PJIs; however, up to 16% of deep incisional and organ-space infections may be missed. Extending the surveillance period to 180 days could allow for a better estimate of disease burden. Infect Control Hosp Epidemiol 2017;38:147-153.

  18. Layer-by-Layer Assembly of Glucose Oxidase on Carbon Nanotube Modified Electrodes.

    PubMed

    Suroviec, Alice H

    2017-01-01

    The use of enzymatically modified electrodes for the detection of glucose or other non-electrochemically active analytes is becoming increasingly common. Direct heterogeneous electron transfer to glucose oxidase has been shown to be kinetically difficult, which is why electron transfer mediators or indirect detection is usually used for monitoring glucose with electrochemical sensors. It has been found, however, that electrodes modified with single or multi-walled carbon nanotubes (CNTs) demonstrate fast heterogeneous electron transfer kinetics as compared to that found for traditional electrodes. Incorporating CNTs into the assembly of electrochemical glucose sensors, therefore, affords the possibility of facile electron transfer to glucose oxidase, and a more direct determination of glucose. This chapter describes the methods used to use CNTs in a layer-by-layer structure along with glucose oxidase to produce an enzymatically modified electrode with high turnover rates, increased stability and shelf-life.

  19. Phytochrome-Mediated Detection of Changes in Reflected Light

    PubMed Central

    Mancinelli, Alberto L.

    1991-01-01

    Measurements of phytochrome photoequilibria and photoconversion rates in vivo, in seedlings of Cucurbita pepo L. exposed to light in growth chambers, indicate that significant changes in the state of phytochrome can be brought about by changes in the quality and quantity of the light reflected from the walls of the growth chambers. The changes in reflected light, although large, were small in terms of the total radiation (direct light from the lamps plus wall-reflected light) to which the seedlings were exposed. The conditions used were approximate simulations of direct and reflected sunlight conditions in the natural environment. Keeping in mind the limitations imposed by the approximation of the simulations, the results from this study are consistent with the hypothesis that, in the natural environment, a plant might be capable of detecting the presence of nearby plants, before being shaded by them, through the phytochrome-mediated perception of changes in reflected light. PMID:16667942

  20. Filter Bank Multicarrier (FBMC) for long-reach intensity modulated optical access networks

    NASA Astrophysics Data System (ADS)

    Saljoghei, Arsalan; Gutiérrez, Fernando A.; Perry, Philip; Barry, Liam P.

    2017-04-01

    Filter Bank Multi Carrier (FBMC) is a modulation scheme which has recently attracted significant interest in both wireless and optical communications. The interest in optical communications arises due to FBMC's capability to operate without a Cyclic Prefix (CP) and its high resilience to synchronisation errors. However, the operation of FBMC in optical access networks has not been extensively studied either in downstream or upstream. In this work we use experimental work to investigate the operation of FBMC in intensity modulated Passive Optical Networks (PONs) employing direct detection in conjunction with both direct and external modulation schemes. The data rates and propagation lengths employed here vary from 8.4 to 14.8 Gb/s and 0-75 km. The results suggest that by using FBMC it is possible to accomplish CP-Less transmission up to 75 km of SSMF in passive links using cost effective intensity modulation and detection schemes.

  1. Detailed noise statistics for an optically preamplified direct detection receiver

    NASA Astrophysics Data System (ADS)

    Danielsen, Soeren Lykke; Mikkelsen, Benny; Durhuus, Terji; Joergensen, Carsten; Stubkjaer, Kristian E.

    We describe the exact statistics of an optically preamplified direct detection receiver by means of the moment generating function. The theory allows an arbitrary shaped electrical filter in the receiver circuit. The moment generating function (MGF) allows for a precise calculation of the error rate by using the inverse Fast Fourier transform (FFT). The exact results are compared with the usual Gaussian approximation (GA), the saddlepoint approximation (SAP) and the modified Chernoff bound (MCB). This comparison shows that the noise is not Gaussian distributed for all values of the optical amplifier gain. In the region from 20-30 dB gain, calculations shows that the GA underestimates the receiver sensitivity while the SAP is very close to the results of our exact model. Using the MGF derived in the article we then find the optimal bandwidth of the electrical filter in the receiver circuit and calculate the sensitivity degradation due to inter symbol interference (ISI).

  2. Hypercharged dark matter and direct detection as a probe of reheating.

    PubMed

    Feldstein, Brian; Ibe, Masahiro; Yanagida, Tsutomu T

    2014-03-14

    The lack of new physics at the LHC so far weakens the argument for TeV scale thermal dark matter. On the other hand, heavier, nonthermal dark matter is generally difficult to test experimentally. Here we consider the interesting and generic case of hypercharged dark matter, which can allow for heavy dark matter masses without spoiling testability. Planned direct detection experiments will be able to see a signal for masses up to an incredible 1010  GeV, and this can further serve to probe the reheating temperature up to about 109  GeV, as determined by the nonthermal dark matter relic abundance. The Z-mediated nature of the dark matter scattering may be determined in principle by comparing scattering rates on different detector nuclei, which in turn can reveal the dark matter mass. We will discuss the extent to which future experiments may be able to make such a determination.

  3. Multiple-Frame Detection of Subpixel Targets in Thermal Image Sequences

    NASA Technical Reports Server (NTRS)

    Thompson, David R.; Kremens, Robert

    2013-01-01

    The new technology in this approach combines the subpixel detection information from multiple frames of a sequence to achieve a more sensitive detection result, using only the information found in the images themselves. It is taken as a constraint that the method is automated, robust, and computationally feasible for field networks with constrained computation and data rates. This precludes simply downloading a video stream for pixel-wise co-registration on the ground. It is also important that this method not require precise knowledge of sensor position or direction, because such information is often not available. It is also assumed that the scene in question is approximately planar, which is appropriate for a high-altitude airborne or orbital view.

  4. Pulmonary-impedance power spectral analysis: A facile means of detecting radiation-induced gastrointestinal distress and performance decrement in man

    NASA Technical Reports Server (NTRS)

    Rick, R. C.; Lushbaugh, C. C.; Mcdow, E.; Frome, E.

    1972-01-01

    Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.

  5. Time-resolved broadband cavity-enhanced absorption spectroscopy for chemical kinetics.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheps, Leonid; Chandler, David W.

    Experimental measurements of elementary reaction rate coefficients and product branching ratios are essential to our understanding of many fundamentally important processes in Combustion Chemistry. However, such measurements are often impossible because of a lack of adequate detection techniques. Some of the largest gaps in our knowledge concern some of the most important radical species, because their short lifetimes and low steady-state concentrations make them particularly difficult to detect. To address this challenge, we propose a novel general detection method for gas-phase chemical kinetics: time-resolved broadband cavity-enhanced absorption spectroscopy (TR-BB-CEAS). This all-optical, non-intrusive, multiplexed method enables sensitive direct probing of transientmore » reaction intermediates in a simple, inexpensive, and robust experimental package.« less

  6. Fault-tolerant quantum error detection

    PubMed Central

    Linke, Norbert M.; Gutierrez, Mauricio; Landsman, Kevin A.; Figgatt, Caroline; Debnath, Shantanu; Brown, Kenneth R.; Monroe, Christopher

    2017-01-01

    Quantum computers will eventually reach a size at which quantum error correction becomes imperative. Quantum information can be protected from qubit imperfections and flawed control operations by encoding a single logical qubit in multiple physical qubits. This redundancy allows the extraction of error syndromes and the subsequent detection or correction of errors without destroying the logical state itself through direct measurement. We show the encoding and syndrome measurement of a fault-tolerantly prepared logical qubit via an error detection protocol on four physical qubits, represented by trapped atomic ions. This demonstrates the robustness of a logical qubit to imperfections in the very operations used to encode it. The advantage persists in the face of large added error rates and experimental calibration errors. PMID:29062889

  7. High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence

    PubMed Central

    Podkowa, Anthony S.; Oelze, Michael L.; Ketterling, Jeffrey A.

    2018-01-01

    The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of ±300 mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow. PMID:29910966

  8. Time-gated luminescence microscopy allowing direct visual inspection of lanthanide-stained microorganisms in background-free condition.

    PubMed

    Jin, Dayong; Piper, James A

    2011-03-15

    Application of standard immuno-fluorescence microscopy techniques for detection of rare-event microorganisms in dirty samples is severely limited by autofluorescence of nontarget organisms or other debris. Time-gated detection using gateable array detectors in combination with microsecond-lifetime luminescent bioprobes (usually lanthanide-based) is highly effective in suppression of (nanosecond-lifetime) autofluorescence background; however, the complexity and cost of the instrumentation is a major barrier to application of these techniques to routine diagnostics. We report a practical, low-cost implementation of time-gated luminescence detection in a standard epifluorescence microscope which has been modified to include a high-power pulsed UV light-emitting diode (LED) illumination source and a standard fast chopper inserted in the focal plane behind a microscope eyepiece. Synchronization of the pulsed illumination/gated detection cycle is driven from the clock signal from the chopper. To achieve time-gated luminescence intensities sufficient for direct visual observation, we use high cycle rates, up to 2.5 kHz, taking advantage of the fast switching capabilities of the LED source. We have demonstrated real-time direct-visual inspection of europium-labeled Giardia lamblia cysts in dirty samples and Cryptosporidium parvum oocysts in fruit juice concentrate. The signal-to-background ratio has been enhanced by a factor of 18 in time-gated mode. The availability of low-cost, robust time-gated microscopes will aid development of long-lifetime luminescence bioprobes and accelerate their application in routine laboratory diagnostics.

  9. Direct-detection Free-space Laser Transceiver Test-bed

    NASA Technical Reports Server (NTRS)

    Krainak, Michael A.; Chen, Jeffrey R.; Dabney, Philip W.; Ferrara, Jeffrey F.; Fong, Wai H.; Martino, Anthony J.; McGarry Jan. F.; Merkowitz, Stephen M.; Principe, Caleb M.; Sun, Siaoli; hide

    2008-01-01

    NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.

  10. Direct Spectroscopic Detection of ATP Turnover Reveals Mechanistic Divergence of ABC Exporters.

    PubMed

    Collauto, Alberto; Mishra, Smriti; Litvinov, Aleksei; Mchaourab, Hassane S; Goldfarb, Daniella

    2017-08-01

    We have applied high-field (W-band) pulse electron-nuclear double resonance (ENDOR) and electron-electron double resonance (ELDOR)-detected nuclear magnetic resonance (EDNMR) to characterize the coordination sphere of the Mn 2+ co-factor in the nucleotide binding sites (NBSs) of ABC transporters. MsbA and BmrCD are two efflux transporters hypothesized to represent divergent catalytic mechanisms. Our results reveal distinct coordination of Mn 2+ to ATP and transporter residues in the consensus and degenerate NBSs of BmrCD. In contrast, the coordination of Mn 2+ at the two NBSs of MsbA is similar, which provides a mechanistic rationale for its higher rate constant of ATP hydrolysis relative to BmrCD. Direct detection of vanadate ion, trapped in a high-energy post-hydrolysis intermediate, further supports the notion of asymmetric hydrolysis by the two NBSs of BmrCD. The integrated spectroscopic approach presented here, which link energy input to conformational dynamics, can be applied to a variety of systems powered by ATP turnover. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. A Robust Semi-Parametric Test for Detecting Trait-Dependent Diversification.

    PubMed

    Rabosky, Daniel L; Huang, Huateng

    2016-03-01

    Rates of species diversification vary widely across the tree of life and there is considerable interest in identifying organismal traits that correlate with rates of speciation and extinction. However, it has been challenging to develop methodological frameworks for testing hypotheses about trait-dependent diversification that are robust to phylogenetic pseudoreplication and to directionally biased rates of character change. We describe a semi-parametric test for trait-dependent diversification that explicitly requires replicated associations between character states and diversification rates to detect effects. To use the method, diversification rates are reconstructed across a phylogenetic tree with no consideration of character states. A test statistic is then computed to measure the association between species-level traits and the corresponding diversification rate estimates at the tips of the tree. The empirical value of the test statistic is compared to a null distribution that is generated by structured permutations of evolutionary rates across the phylogeny. The test is applicable to binary discrete characters as well as continuous-valued traits and can accommodate extremely sparse sampling of character states at the tips of the tree. We apply the test to several empirical data sets and demonstrate that the method has acceptable Type I error rates. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Antineutrino monitoring of thorium reactors

    DOE PAGES

    Akindele, Oluwatomi A.; Bernstein, Adam; Norman, Eric B.

    2016-09-30

    Various groups have demonstrated that antineutrino monitoring can be successful in assessing the plutonium content in water-cooled nuclear reactors for nonproliferation applications. New reactor designs and concepts incorporate nontraditional fuel types and chemistry. Understanding how these properties affect the antineutrino emission from a reactor can extend the applicability of antineutrino monitoring. Thorium molten salt reactors breed 233U, that if diverted constitute a direct use material as defined by the International Atomic Energy Agency (IAEA). The antineutrino spectrum from the fission of 233U has been estimated for the first time, and the feasibility of detecting the diversion of 8 kg ofmore » 233U, within a 30 day timeliness goal has been evaluated. The antineutrino emission from a thorium reactor operating under normal conditions is compared to a diversion scenario by evaluating the daily antineutrino count rate and the energy spectrum of the detected antineutrinos at a 25 m standoff. It was found that the diversion of a significant quantity of 233U could not be detected within the current IAEA timeliness detection goal using either tests. In conclusion, a rate-time based analysis exceeded the timeliness goal by 23 days, while a spectral based analysis exceeds this goal by 31 days.« less

  13. Antineutrino monitoring of thorium reactors

    NASA Astrophysics Data System (ADS)

    Akindele, Oluwatomi A.; Bernstein, Adam; Norman, Eric B.

    2016-09-01

    Various groups have demonstrated that antineutrino monitoring can be successful in assessing the plutonium content in water-cooled nuclear reactors for nonproliferation applications. New reactor designs and concepts incorporate nontraditional fuel types and chemistry. Understanding how these properties affect the antineutrino emission from a reactor can extend the applicability of antineutrino monitoring. Thorium molten salt reactors breed 233U, that if diverted constitute a direct use material as defined by the International Atomic Energy Agency (IAEA). The antineutrino spectrum from the fission of 233U has been estimated for the first time, and the feasibility of detecting the diversion of 8 kg of 233U, within a 30 day timeliness goal has been evaluated. The antineutrino emission from a thorium reactor operating under normal conditions is compared to a diversion scenario by evaluating the daily antineutrino count rate and the energy spectrum of the detected antineutrinos at a 25 m standoff. It was found that the diversion of a significant quantity of 233U could not be detected within the current IAEA timeliness detection goal using either tests. A rate-time based analysis exceeded the timeliness goal by 23 days, while a spectral based analysis exceeds this goal by 31 days.

  14. Nitrite oxidation in the Namibian oxygen minimum zone.

    PubMed

    Füssel, Jessika; Lam, Phyllis; Lavik, Gaute; Jensen, Marlene M; Holtappels, Moritz; Günter, Marcel; Kuypers, Marcel M M

    2012-06-01

    Nitrite oxidation is the second step of nitrification. It is the primary source of oceanic nitrate, the predominant form of bioavailable nitrogen in the ocean. Despite its obvious importance, nitrite oxidation has rarely been investigated in marine settings. We determined nitrite oxidation rates directly in (15)N-incubation experiments and compared the rates with those of nitrate reduction to nitrite, ammonia oxidation, anammox, denitrification, as well as dissimilatory nitrate/nitrite reduction to ammonium in the Namibian oxygen minimum zone (OMZ). Nitrite oxidation (≤372 nM NO(2)(-) d(-1)) was detected throughout the OMZ even when in situ oxygen concentrations were low to non-detectable. Nitrite oxidation rates often exceeded ammonia oxidation rates, whereas nitrate reduction served as an alternative and significant source of nitrite. Nitrite oxidation and anammox co-occurred in these oxygen-deficient waters, suggesting that nitrite-oxidizing bacteria (NOB) likely compete with anammox bacteria for nitrite when substrate availability became low. Among all of the known NOB genera targeted via catalyzed reporter deposition fluorescence in situ hybridization, only Nitrospina and Nitrococcus were detectable in the Namibian OMZ samples investigated. These NOB were abundant throughout the OMZ and contributed up to ~9% of total microbial community. Our combined results reveal that a considerable fraction of the recently recycled nitrogen or reduced NO(3)(-) was re-oxidized back to NO(3)(-) via nitrite oxidation, instead of being lost from the system through the anammox or denitrification pathways.

  15. Development of factors to convert frequency to rate for β-cell replication and apoptosis quantified by time-lapse video microscopy and immunohistochemistry

    PubMed Central

    Saisho, Yoshifumi; Manesso, Erica; Gurlo, Tatyana; Huang, Chang-jiang; Toffolo, Gianna M.; Cobelli, Claudio; Butler, Peter C.

    2009-01-01

    An obstacle to development of methods to quantify β-cell turnover from pancreas tissue is the lack of conversion factors for the frequency of β-cell replication or apoptosis detected by immunohistochemistry to rates of replication or apoptosis. We addressed this obstacle in islets from 1-mo-old rats by quantifying the relationship between the rate of β-cell replication observed directly by time-lapse video microscopy (TLVM) and the frequency of β-cell replication in the same islets detected by immunohistochemistry using antibodies against Ki67 and insulin in the same islets fixed immediately after TLVM. Similarly, we quantified the rate of β-cell apoptosis by TLVM and then the frequency of apoptosis in the same islets using TdT-mediated dUTP nick-end labeling and insulin. Conversion factors were developed by regression analysis. The conversion factor from Ki67 labeling frequency (%) to actual replication rate (%events/h) is 0.025 ± 0.003 h−1. The conversion factor from TdT-mediated dUTP nick-end labeling frequency (%) to actual apoptosis rate (%events/h) is 0.41 ± 0.05 h−1. These conversion factors will permit development of models to evaluate β-cell turnover in fixed pancreas tissue. PMID:18940937

  16. The effect of presentation level and stimulation rate on speech perception and modulation detection for cochlear implant users.

    PubMed

    Brochier, Tim; McDermott, Hugh J; McKay, Colette M

    2017-06-01

    In order to improve speech understanding for cochlear implant users, it is important to maximize the transmission of temporal information. The combined effects of stimulation rate and presentation level on temporal information transfer and speech understanding remain unclear. The present study systematically varied presentation level (60, 50, and 40 dBA) and stimulation rate [500 and 2400 pulses per second per electrode (pps)] in order to observe how the effect of rate on speech understanding changes for different presentation levels. Speech recognition in quiet and noise, and acoustic amplitude modulation detection thresholds (AMDTs) were measured with acoustic stimuli presented to speech processors via direct audio input (DAI). With the 500 pps processor, results showed significantly better performance for consonant-vowel nucleus-consonant words in quiet, and a reduced effect of noise on sentence recognition. However, no rate or level effect was found for AMDTs, perhaps partly because of amplitude compression in the sound processor. AMDTs were found to be strongly correlated with the effect of noise on sentence perception at low levels. These results indicate that AMDTs, at least when measured with the CP910 Freedom speech processor via DAI, explain between-subject variance of speech understanding, but do not explain within-subject variance for different rates and levels.

  17. High resolution melting analysis for epidermal growth factor receptor mutations in formalin-fixed paraffin-embedded tissue and plasma free DNA from non-small cell lung cancer patients.

    PubMed

    Jing, Chang-Wen; Wang, Zhuo; Cao, Hai-Xia; Ma, Rong; Wu, Jian-Zhong

    2014-01-01

    The aim of the research was to explore a cost effective, fast, easy to perform, and sensitive method for epidermal growth factor receptor (EGFR) mutation testing. High resolution melting analysis (HRM) was introduced to evaluate the efficacy of the analysis for dectecting EGFR mutations in exons 18 to 21 using formalin-fixed paraffin-embedded (FFPE) tissues and plasma free DNA from 120 patients. The total EGFR mutation rate was 37.5% (45/120) detected by direct sequencing. There were 48 mutations in 120 FFPE tissues assessed by HRM. For plasma free DNA, the EGFR mutation rate was 25.8% (31/120). The sensitivity of HRM assays in FFPE samples was 100% by HRM. There was a low false-positive mutation rate but a high false-negative rate in plasma free DNA detected by HRM. Our results show that HRM analysis has the advantage of small tumor sample need. HRM applied with plasma free DNA showed a high false-negative rate but a low false-positive rate. Further research into appropriate methods and analysis needs to be performed before HRM for plasma free DNA could be accepted as an option in diagnostic or screening settings.

  18. Direct Sequence Detection of Structured H5 Influenza Viral RNA

    PubMed Central

    Kerby, Matthew B.; Freeman, Sarah; Prachanronarong, Kristina; Artenstein, Andrew W.; Opal, Steven M.; Tripathi, Anubhav

    2008-01-01

    We describe the development of sequence-specific molecular beacons (dual-labeled DNA probes) for identification of the H5 influenza subtype, cleavage motif, and receptor specificity when hybridized directly with in vitro transcribed viral RNA (vRNA). The cloned hemagglutinin segment from a highly pathogenic H5N1 strain, A/Hanoi/30408/2005(H5N1), isolated from humans was used as template for in vitro transcription of sense-strand vRNA. The hybridization behavior of vRNA and a conserved subtype probe was characterized experimentally by varying conditions of time, temperature, and Mg2+ to optimize detection. Comparison of the hybridization rates of probe to DNA and RNA targets indicates that conformational switching of influenza RNA structure is a rate-limiting step and that the secondary structure of vRNA dominates the binding kinetics. The sensitivity and specificity of probe recognition of other H5 strains was calculated from sequence matches to the National Center for Biotechnology Information influenza database. The hybridization specificity of the subtype probes was experimentally verified with point mutations within the probe loop at five locations corresponding to the other human H5 strains. The abundance frequencies of the hemagglutinin cleavage motif and sialic acid recognition sequences were experimentally tested for H5 in all host viral species. Although the detection assay must be coupled with isothermal amplification on the chip, the new probes form the basis of a portable point-of-care diagnostic device for influenza subtyping. PMID:18403607

  19. Sensitive Detection of Francisella tularensis Directly from Whole Blood by Use of the GeneXpert System.

    PubMed

    Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David

    2017-01-01

    Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.

  20. Detection of bacteria in suspension using a superconducting Quantum interference device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grossman, H.L.; Myers, W.R.; Vreeland, V.J.

    2003-06-09

    We demonstrate a technique for detecting magnetically-labeled Listeria monocytogenes and for measuring the binding rate between antibody-linked magnetic particles and bacteria. This assay, which is both sensitive and straightforward to perform, can quantify specific bacteria in a sample without the need to immobilize the bacteria or wash away unbound magnetic particles. In the measurement, we add 50 nm diameter superparamagnetic particles, coated with antibodies, to a liquid sample containing L. monocytogenes. We apply a pulsed magnetic field to align the magnetic dipole moments and use a high transition temperature Superconducting Quantum Interference Device (SQUID), an extremely sensitive detector of magneticmore » flux, to measure the magnetic relaxation signal when the field is turned off. Unbound particles randomize direction by Brownian rotation too quickly to be detected. In contrast, particles bound to L. monocytogenes are effectively immobilized and relax in about 1 s by rotation of the internal dipole moment. This Neel relaxation process is detected by the SQUID. The measurements indicate a detection limit of (5.6 {+-} 1.1) x 10{sup 6} L. monocytogenes for a 20 {micro}L sample volume. If the sample volume were reduced to 1 nL, we estimate that the detection limit could be improved to 230 {+-} 40 L. monocytogenes cells. Time-resolved measurements yield the binding rate between the particles and bacteria.« less

  1. FTIR gas analysis with improved sensitivity and selectivity for CWA and TIC detection

    NASA Astrophysics Data System (ADS)

    Phillips, Charles M.; Tan, Huwei

    2010-04-01

    This presentation describes the use of an FTIR (Fourier Transform Infrared)-based spectrometer designed to continuously monitor ambient air for the presence of chemical warfare agents (CWAs) and toxic industrial chemicals (TICs). The necessity of a reliable system capable of quickly and accurately detecting very low levels of CWAs and TICs while simultaneously retaining a negligible false alarm rate will be explored. Technological advancements in FTIR sensing have reduced noise while increasing selectivity and speed of detection. These novel analyzer design characteristics are discussed in detail and descriptions are provided which show how optical throughput, gas cell form factor, and detector response are optimized. The hardware and algorithms described here will explain why this FTIR system is very effective for the simultaneous detection and speciation of a wide variety of toxic compounds at ppb concentrations. Analytical test data will be reviewed demonstrating the system's sensitivity to and selectivity for specific CWAs and TICs; this will include recent data acquired as part of the DHS ARFCAM (Autonomous Rapid Facility Chemical Agent Monitor) project. These results include analyses of the data from live agent testing for the determination of CWA detection limits, immunity to interferences, detection times, residual noise analysis and false alarm rates. Sensing systems such as this are critical for effective chemical hazard identification which is directly relevant to the CBRNE community.

  2. Agricultural land use doubled sediment yield of western China's rivers

    NASA Astrophysics Data System (ADS)

    Schmidt, A. H.; Bierman, P. R.; Sosa-Gonzalez, V.; Neilson, T. B.; Rood, D. H.; Martin, J.; Hill, M.

    2017-12-01

    Land use changes, such as deforestation and agriculture, increase soil erosion rates on the scale of hillslopes and small drainage basins; however, the effects of these changes on the sediment load in larger rivers is poorly quantified, with a few studies scattered globally, and only 10 data points in the world's most populous nation, China. At 20 different sites in western China, we compare contemporary (1945-1987) fluvial sediment yield data collected daily over 4 to 26 years (median = 19 years) to long-term measures of erosion (sediment generation) based on new isotopic measurements of in situ 10Be in river sediments. We find that median sediment transport at these sites exceeds background sediment generation rates by a factor of two (from 0.13 to 5.79 times, median 1.85 times) and that contemporary sediment yield is statistically significantly different from long-term sediment yield (p < 0.05). Agricultural land use is directly and significantly proportional to the ratio of contemporary sediment yield to long term sediment generation rates (Spearman correlation coefficient rho = 0.52, p < 0.05). We support these findings by calculating erosion indices (following Brown et al., 1988), which compare the delivery of meteoric 10Be to each watershed with the export of meteoric 10Be bound to riverine sediment. Erosion indices are also directly and significantly proportional to agricultural land use (rho = 0.58, p < 0.05). We measured unsupported 210Pb and 137Cs in 130 detrital samples from throughout the region. We find that only 4 samples (those from high elevation, low relief watersheds) have detectable 137Cs and 31 samples have detectable unsupported 210Pb. The lack of 137Cs in most samples suggests high rates of erosion in the 1950s-1960s when 137Cs would have been delivered to the landscape. Detectable 210Pb in 25% of the watersheds suggests that in some areas erosion rates have slowed since that time allowing 210Pb to accumulate to measurable levels. Together, these data sets demonstrate that upstream agricultural land use has significantly increased sediment supply to rivers in western China, likely increasing turbidity and decreasing ecosystem services such as fisheries.

  3. Utilizing a Water-Soluble Cryptophane with Fast Xenon Exchange Rates for Picomolar Sensitivity NMR Measurements

    PubMed Central

    Bai, Yubin; Hill, P. Aru; Dmochowski, Ivan J.

    2012-01-01

    Hyperpolarized 129Xe chemical exchange saturation transfer (129Xe Hyper-CEST) NMR is a powerful technique for the ultrasensitive, indirect detection of Xe host molecules (e.g., cryptophane-A). Irradiation at the appropriate Xe-cryptophane resonant radio frequency results in relaxation of the bound hyperpolarized 129Xe and rapid accumulation of depolarized 129Xe in bulk solution. The cryptophane effectively ‘catalyzes’ this process by providing a unique molecular environment for spin depolarization to occur, while allowing xenon exchange with the bulk solution during the hyperpolarized lifetime (T1 ≈ 1 min). Following this scheme, a triacetic acid cryptophane-A derivative (TAAC) was indirectly detected at 1.4 picomolar concentration at 320 K in aqueous solution, which is the record for a single-unit xenon host. To investigate this sensitivity enhancement, the xenon binding kinetics of TAAC in water was studied by NMR exchange lifetime measurement. At 297 K, kon ≈ 1.5 × 106 M−1s−1 and koff = 45 s−1, which represent the fastest Xe association and dissociation rates measured for a high-affinity, water-soluble xenon host molecule near rt. NMR linewidth measurements provided similar exchange rates at rt, which we assign to solvent-Xe exchange in TAAC. At 320 K, koff was estimated to be 1.1 × 103 s−1. In Hyper-CEST NMR experiments, the rate of 129Xe depolarization achieved by 14 pM TAAC in the presence of RF pulses was calculated to be 0.17 µM·s−1. On a per cryptophane basis, this equates to 1.2 × 104 129Xe atoms s−1 (or 4.6 × 104 Xe atoms s−1, all Xe isotopes), which is more than an order of magnitude faster than koff, the directly measurable Xe-TAAC exchange rate. This compels us to consider multiple Xe exchange processes for cryptophane-mediated bulk 129Xe depolarization, which provide at least 107-fold sensitivity enhancements over directly detected hyperpolarized 129Xe NMR signals. PMID:23106513

  4. Oligorecurrent prostate cancer limited to lymph nodes: getting our ducks in a row

    PubMed

    Fodor, Andrei; Lancia, Andrea; Ceci, Francesco; Picchio, Maria; Hoyer, Morten; Jereczek-Fossa, Barbara Alicja; Ost, Piet; Castellucci, Paolo; Incerti, Elena; Di Muzio, Nadia; Ingrosso, Gianluca

    2018-05-11

    Oligorecurrent prostate cancer with exclusive nodal involvement represents a common state of disease, amenable to local therapy. New radio-labeled tracers have enriched the possibility of cancer detection and treatment. In this review, we aim to illustrate the main nuclear medicine diagnostic options and the role of radiotherapy in this setting of patients. We performed a PubMed search referring to the PRISMA guidelines to analyze the performance of PSMA- and choline-PET in detecting oligorecurrence limited to lymph nodes, and to review the main studies supporting either ablative stereotactic body radiotherapy or regional lymph node irradiation in this clinical setting. PSMA-PET has shown higher efficacy in the diagnosis of nodal lesions if compared with choline-PET. More specifically, for PSA ≤ 2 ng/ml, the median detection rate of choline-PET ranges from 19.5 to 44.5%, whereas PSMA ranges from 51.5 to 74%. SBRT achieves high local control rates positively affecting progression-free survival (PFS), with androgen deprivation therapy (ADT)-free survival ranging from 25 to 44 months and with low toxicity rates (0-15%). Prophylactic nodal irradiation shows 3-year PFS rates ranging from 62 to 75%, but with a potential higher risk of toxicity. However, the chosen treatment option needs to be tailored on the single patient. Newer PET/CT radio-labeled tracers have increased disease detection in oligorecurrent prostate cancer patients. Growing evidence of their impact on metastasis-directed therapy encourages the use of the most advanced radiotherapy techniques in the clinical management of such patients.

  5. Higher Education Policy Change in the European Higher Education Area: Divergence of Quality Assurance Systems in England and the Netherlands

    ERIC Educational Resources Information Center

    Hsieh, Chuo-Chun; Huisman, Jeroen

    2017-01-01

    In the context of globalising higher education (HE) policies, there is an increasing interest among scholars in detecting patterns of policy change, including the rate and magnitude of policy change and the direction of change (convergence or divergence) This paper adds to that literature by comparing the pattern of policy change and by providing…

  6. High-throughput diagnosis of potato cyst nematodes in soil samples.

    PubMed

    Reid, Alex; Evans, Fiona; Mulholland, Vincent; Cole, Yvonne; Pickup, Jon

    2015-01-01

    Potato cyst nematode (PCN) is a damaging soilborne pest of potatoes which can cause major crop losses. In 2010, a new European Union directive (2007/33/EC) on the control of PCN came into force. Under the new directive, seed potatoes can only be planted on land which has been found to be free from PCN infestation following an official soil test. A major consequence of the new directive was the introduction of a new harmonized soil sampling rate resulting in a threefold increase in the number of samples requiring testing. To manage this increase with the same staffing resources, we have replaced the traditional diagnostic methods. A system has been developed for the processing of soil samples, extraction of DNA from float material, and detection of PCN by high-throughput real-time PCR. Approximately 17,000 samples are analyzed each year using this method. This chapter describes the high-throughput processes for the production of float material from soil samples, DNA extraction from the entire float, and subsequent detection and identification of PCN within these samples.

  7. Higgs portal dark matter in non-standard cosmological histories

    NASA Astrophysics Data System (ADS)

    Hardy, Edward

    2018-06-01

    A scalar particle with a relic density set by annihilations through a Higgs portal operator is a simple and minimal possibility for dark matter. However, assuming a thermal cosmological history this model is ruled out over most of parameter space by collider and direct detection constraints. We show that in theories with a non-thermal cosmological history Higgs portal dark matter is viable for a wide range of dark matter masses and values of the portal coupling, evading existing limits. In particular, we focus on the string theory motivated scenario of a period of matter domination due to a light modulus with a decay rate that is suppressed by the Planck scale. Dark matter with a mass ≲ GeV is possible without additional hidden sector states, and this can have astrophysically relevant self-interactions. We also study the signatures of such models at future direct, indirect, and collider experiments. Searches for invisible Higgs decays at the high luminosity LHC or an e + e - collider could cover a significant proportion of the parameter space for low mass dark matter, and future direct detection experiments will play a complementary role.

  8. Automatic cardiac cycle determination directly from EEG-fMRI data by multi-scale peak detection method.

    PubMed

    Wong, Chung-Ki; Luo, Qingfei; Zotev, Vadim; Phillips, Raquel; Chan, Kam Wai Clifford; Bodurka, Jerzy

    2018-03-31

    In simultaneous EEG-fMRI, identification of the period of cardioballistic artifact (BCG) in EEG is required for the artifact removal. Recording the electrocardiogram (ECG) waveform during fMRI is difficult, often causing inaccurate period detection. Since the waveform of the BCG extracted by independent component analysis (ICA) is relatively invariable compared to the ECG waveform, we propose a multiple-scale peak-detection algorithm to determine the BCG cycle directly from the EEG data. The algorithm first extracts the high contrast BCG component from the EEG data by ICA. The BCG cycle is then estimated by band-pass filtering the component around the fundamental frequency identified from its energy spectral density, and the peak of BCG artifact occurrence is selected from each of the estimated cycle. The algorithm is shown to achieve a high accuracy on a large EEG-fMRI dataset. It is also adaptive to various heart rates without the needs of adjusting the threshold parameters. The cycle detection remains accurate with the scan duration reduced to half a minute. Additionally, the algorithm gives a figure of merit to evaluate the reliability of the detection accuracy. The algorithm is shown to give a higher detection accuracy than the commonly used cycle detection algorithm fmrib_qrsdetect implemented in EEGLAB. The achieved high cycle detection accuracy of our algorithm without using the ECG waveforms makes possible to create and automate pipelines for processing large EEG-fMRI datasets, and virtually eliminates the need for ECG recordings for BCG artifact removal. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Damage detection based on acceleration data using artificial immune system

    NASA Astrophysics Data System (ADS)

    Chartier, Sandra; Mita, Akira

    2009-03-01

    Nowadays, Structural Health Monitoring (SHM) is essential in order to prevent damages occurrence in civil structures. This is a particularly important issue as the number of aged structures is increasing. Damage detection algorithms are often based on changes in the modal properties like natural frequencies, modal shapes and modal damping. In this paper, damage detection is completed by using Artificial Immune System (AIS) theory directly on acceleration data. Inspired from the biological immune system, AIS is composed of several models like negative selection which has a great potential for this study. The negative selection process relies on the fact that T-cells, after their maturation, are sensitive to non self cells and can not detect self cells. Acceleration data were provided by using the numerical model of a 3-story frame structure. Damages were introduced, at particular times, by reduction of story's stiffness. Based on these acceleration data, undamaged data (equivalent to self data) and damaged data (equivalent to non self data) can be obtained and represented in the Hamming shape-space with a binary representation. From the undamaged encoded data, detectors (equivalent to T-cells) are derived and are able to detect damaged encoded data really efficiently by using the rcontiguous bits matching rule. Indeed, more than 95% of detection can be reached when efficient combinations of parameters are used. According to the number of detected data, the localization of damages can even be determined by using the differences between story's relative accelerations. Thus, the difference which presents the highest detection rate, generally up to 89%, is directly linked to the location of damage.

  10. Detection of schistosomiasis in an area directly affected by the São Francisco River large-scale water transposition project in the Northeast of Brazil.

    PubMed

    Silva, José Damião da; Pinheiro, Marta Cristhiany Cunha; Sousa, Mariana Silva; Gomes, Vivian da Silva; Castro, Issis Maria Nogueira de; Ramos, Alberto Novaes; Bezerra, Fernando Schemelzer de Moraes

    2017-01-01

    The development of the São Francisco River Integration Project [Projeto de Integração do Rio São Francisco (PISF)] in the State of Ceará, Brazil, has resulted in environmental and socioeconomic changes with potential risks to public health. We aimed to determine the presence of Schistosoma mansoni infections in schoolchildren (aged 7-14 years) and workers from the construction site in an area under the direct influence of the PISF in the municipality of Brejo Santo-CE, to aid in the prevention and control of schistosomiasis. We conducted a cross-sectional study using two S. mansoni-detection methods: detection of S. mansoni eggs by the Kato-Katz parasitological method in stool samples (assessed in triplicate for each sample) and S. mansoni circulating cathodic antigen by the point-of-care immunochromatographic rapid test (POC-CCA) in urine. In general, the positivity rates for S. mansoni detection were 1.9% (2/106) among schoolchildren and 2.9% (4/138) among workers. No child had evidence of S. mansoni eggs in their stools; 1.9% tested positive by the POC-CCA method. Among workers, two (1.4%) tested positive by the Kato-Katz test and three (2.2%) by the POC-CCA test. If the POC-CCA test results that were scored as traces were considered negative, then the positivity rates dropped to 0.9% and 0.7% for schoolchildren and workers, respectively. The active transmission of schistosomiasis in a region covered by the PISF was recognized, reinforcing the necessity to consolidate surveillance and control actions, as well as structural sanitation measures to reverse the social determinants of the disease.

  11. Detection of a pair of prominent X-ray cavities in Abell 3847

    NASA Astrophysics Data System (ADS)

    Vagshette, Nilkanth D.; Naik, Sachindra; Patil, Madhav. K.; Sonkamble, Satish S.

    2017-04-01

    We present the results obtained from a detailed analysis of a deep Chandra observation of the bright FRII radio galaxy 3C 444 in Abell 3847 cluster. A pair of huge X-ray cavities are detected along the north and south directions from the centre of 3C 444. X-ray and radio images of the cluster reveal peculiar positioning of the cavities and radio bubbles. The radio lobes and X-ray cavities are apparently not spatially coincident and exhibit offsets by ˜61 and 77 kpc from each other along the north and south directions, respectively. Radial temperature and density profiles reveal the presence of a cool core in the cluster. Imaging and spectral studies showed the removal of substantial amount of matter from the core of the cluster by the radio jets. A detailed analysis of the temperature and density profiles showed the presence of a rarely detected elliptical shock in the cluster. Detection of inflating cavities at an average distance of ˜55 kpc from the centre implies that the central engine feeds a remarkable amount of radio power (˜6.3 × 1044 erg s-1) into the intra-cluster medium over ˜108 yr, the estimated age of cavity. The cooling luminosity of the cluster was estimated to be ˜8.30 × 1043 erg s-1 , which confirms that the AGN power is sufficient to quench the cooling. Ratios of mass accretion rate to Eddington and Bondi rates were estimated to be ˜0.08 and 3.5 × 104, respectively. This indicates that the black hole in the core of the cluster accretes matter through chaotic cold accretion.

  12. Development of a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a highly sensitive detection of enterovirus in the stool samples of acute flaccid paralysis cases.

    PubMed

    Arita, Minetaro; Ling, Hua; Yan, Dongmei; Nishimura, Yorihiro; Yoshida, Hiromu; Wakita, Takaji; Shimizu, Hiroyuki

    2009-12-16

    In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts.

  13. Optimal search strategies of space-time coupled random walkers with finite lifetimes

    NASA Astrophysics Data System (ADS)

    Campos, D.; Abad, E.; Méndez, V.; Yuste, S. B.; Lindenberg, K.

    2015-05-01

    We present a simple paradigm for detection of an immobile target by a space-time coupled random walker with a finite lifetime. The motion of the walker is characterized by linear displacements at a fixed speed and exponentially distributed duration, interrupted by random changes in the direction of motion and resumption of motion in the new direction with the same speed. We call these walkers "mortal creepers." A mortal creeper may die at any time during its motion according to an exponential decay law characterized by a finite mean death rate ωm. While still alive, the creeper has a finite mean frequency ω of change of the direction of motion. In particular, we consider the efficiency of the target search process, characterized by the probability that the creeper will eventually detect the target. Analytic results confirmed by numerical results show that there is an ωm-dependent optimal frequency ω =ωopt that maximizes the probability of eventual target detection. We work primarily in one-dimensional (d =1 ) domains and examine the role of initial conditions and of finite domain sizes. Numerical results in d =2 domains confirm the existence of an optimal frequency of change of direction, thereby suggesting that the observed effects are robust to changes in dimensionality. In the d =1 case, explicit expressions for the probability of target detection in the long time limit are given. In the case of an infinite domain, we compute the detection probability for arbitrary times and study its early- and late-time behavior. We further consider the survival probability of the target in the presence of many independent creepers beginning their motion at the same location and at the same time. We also consider a version of the standard "target problem" in which many creepers start at random locations at the same time.

  14. Exploring relationships of calcification rate with respiration rate and predator cue presence in juvenile Crassostrea virginica

    NASA Astrophysics Data System (ADS)

    McCutcheon, M.; Hu, X.

    2016-02-01

    The eastern oyster (Crassostrea virginica) is a biologically and economically important calcifier that has been experiencing a global population decline due to multiple stressors. The process of biomineralization is essential in the growth and predator defense of oysters. Several studies investigating morphological and mechanical shell properties have noted a phenotypic plasticity in response to predator presence. We present the first study that attempts to detect an alteration in the calcification rate of juvenile C. virginica as well as measure respiration rates in the presence and absence of predator exudates. An alkalinity anomaly technique was used to quantify calcification and respiration rates of oysters exposed to blue crab or mud crab cues or a no cue control condition. No significant differences in calcification rate were detected between predator and control treatments. However, the linear relationship between calcification and respiration rates differed between treatments. This changing relationship is not fully understood and warrants further investigation. In addition, this study also revealed our experimental oysters maintained calcification rates comparable to literature values while respiration rates were an order of magnitude lower than previously reported levels. Future direction for this research involves inclusion of acidification treatments. Any environmental factors (including predator presence) that may on their own or in conjunction with estuarine acidification alter calcification (or respiration) rates will impact the local to regional carbon cycle as well as oyster fitness and consequent future population dynamics.

  15. Passive acoustic monitoring to detect spawning in large-bodied catostomids

    USGS Publications Warehouse

    Straight, Carrie A.; Freeman, Byron J.; Freeman, Mary C.

    2014-01-01

    Documenting timing, locations, and intensity of spawning can provide valuable information for conservation and management of imperiled fishes. However, deep, turbid or turbulent water, or occurrence of spawning at night, can severely limit direct observations. We have developed and tested the use of passive acoustics to detect distinctive acoustic signatures associated with spawning events of two large-bodied catostomid species (River Redhorse Moxostoma carinatum and Robust Redhorse Moxostoma robustum) in river systems in north Georgia. We deployed a hydrophone with a recording unit at four different locations on four different dates when we could both record and observe spawning activity. Recordings captured 494 spawning events that we acoustically characterized using dominant frequency, 95% frequency, relative power, and duration. We similarly characterized 46 randomly selected ambient river noises. Dominant frequency did not differ between redhorse species and ranged from 172.3 to 14,987.1 Hz. Duration of spawning events ranged from 0.65 to 11.07 s, River Redhorse having longer durations than Robust Redhorse. Observed spawning events had significantly higher dominant and 95% frequencies than ambient river noises. We additionally tested software designed to automate acoustic detection. The automated detection configurations correctly identified 80–82% of known spawning events, and falsely indentified spawns 6–7% of the time when none occurred. These rates were combined over all recordings; rates were more variable among individual recordings. Longer spawning events were more likely to be detected. Combined with sufficient visual observations to ascertain species identities and to estimate detection error rates, passive acoustic recording provides a useful tool to study spawning frequency of large-bodied fishes that displace gravel during egg deposition, including several species of imperiled catostomids.

  16. Development and evaluation of an off-the-slide genotyping technique for identifying Giardia cysts and Cryptosporidium oocysts directly from US EPA Method 1623 slides.

    PubMed

    Ware, M W; Keely, S P; Villegas, E N

    2013-07-01

    This study developed and systematically evaluated performance and limit of detection of an off-the-slide genotyping procedure for both Cryptosporidium oocysts and Giardia cysts. Slide standards containing flow-sorted (oo)cysts were used to evaluate the off-the-slide genotyping procedure by microscopy and PCR. Results show approximately 20% of cysts and oocysts are lost during staining. Although transfer efficiency from the slide to the PCR tube could not be determined by microscopy, it was observed that the transfer process aided in the physical lysis of the (oo)cysts likely releasing DNA. PCR detection rates for a single event on a slide were 44% for Giardia and 27% for Cryptosporidium, and a minimum of five cysts and 20 oocysts are required to achieve a 90% PCR detection rate. A Poisson distribution analysis estimated the relative PCR target densities and limits of detection, it showed that 18 Cryptosporidium and five Giardia replicates are required for a 95% probability of detecting a single (oo)cyst on a slide. This study successfully developed and evaluated recovery rates and limits of detection of an off-the-slide genotyping procedure for both Cryptosporidium and Giardia (oo)cysts from the same slide. This off-the-slide genotyping technique is a simple and low cost tool that expands the applications of US EPA Method 1623 results by identifying the genotypes and assemblages of the enumerated Cryptosporidium and Giardia. This additional information will be useful for microbial risk assessment models and watershed management decisions. Journal of Applied Microbiology Published [2013]. This article is a U.S. Government work and is in the public domain in the USA.

  17. The role of direct photolysis and indirect photochemistry in the environmental fate of ethylhexyl methoxy cinnamate (EHMC) in surface waters.

    PubMed

    Vione, D; Calza, P; Galli, F; Fabbri, D; Santoro, V; Medana, C

    2015-12-15

    The aquatic environmental fate of ethylhexyl methoxy cinnamate (EHMC), one of the most used UVB filters worldwide, was studied by assessing its environmental persistence and photoinduced transformations. The role of direct and indirect photolysis was evaluated. Direct photolysis was shown to play a key role, and this process is expected to be the main attenuation route of EHMC in sunlit surface waters. In contrast, the reaction with OH radicals would be negligible and that with (3)CDOM* would at most be a secondary process. The measurement of the quantum yield of direct photolysis and of the rate constants of reaction with photogenerated transient species (or, sometimes, the use of reasonable values for the latter) allowed the prediction of the EHMC half-life time in surface waters, by means of a validated photochemical model. The predicted EHMC lifetime is of the order of hours to a few days in fair-weather summertime, and the main factors controlling the EHMC phototransformation in sunlit surface waters would be the water depth and the dissolved organic carbon (DOC) content. The formation of transformation products (TPs) was followed as well via HPLC/HRMS. Three TPs were detected in the samples exposed to UVA radiation, while one additional TP was detected in the samples exposed to UVB radiation. The detected TPs comprised 4-methoxybenzaldehyde, a hydroxylated derivative and dimeric species. Through the use of heterogeneous photocatalysis with TiO2, seven additional TPs were identified, most of them resulting from the further degradation of primary TPs formed through direct photolysis and that might be detected in aquatic systems as well. The photodegradation of EHMC in the presence of TiO2 yielded more toxic TPs than the parent compound (as determined with the Vibrio fischeri Microtox assay). The increased toxicity is partially accounted for by the formation of 4-methoxybenzaldehyde. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Battista, L.; Sciuto, S. A.; Scorza, A.

    2013-03-15

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it;more » the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.« less

  19. Detection of Movement Related Cortical Potentials from EEG Using Constrained ICA for Brain-Computer Interface Applications.

    PubMed

    Karimi, Fatemeh; Kofman, Jonathan; Mrachacz-Kersting, Natalie; Farina, Dario; Jiang, Ning

    2017-01-01

    The movement related cortical potential (MRCP), a slow cortical potential from the scalp electroencephalogram (EEG), has been used in real-time brain-computer-interface (BCI) systems designed for neurorehabilitation. Detecting MPCPs in real time with high accuracy and low latency is essential in these applications. In this study, we propose a new MRCP detection method based on constrained independent component analysis (cICA). The method was tested for MRCP detection during executed and imagined ankle dorsiflexion of 24 healthy participants, and compared with four commonly used spatial filters for MRCP detection in an offline experiment. The effect of cICA and the compared spatial filters on the morphology of the extracted MRCP was evaluated by two indices quantifying the signal-to-noise ratio and variability of the extracted MRCP. The performance of the filters for detection was then directly compared for accuracy and latency. The latency obtained with cICA (-34 ± 29 ms motor execution (ME) and 28 ± 16 ms for motor imagery (MI) dataset) was significantly smaller than with all other spatial filters. Moreover, cICA resulted in greater true positive rates (87.11 ± 11.73 for ME and 86.66 ± 6.96 for MI dataset) and lower false positive rates (20.69 ± 13.68 for ME and 19.31 ± 12.60 for MI dataset) compared to the other methods. These results confirm the superiority of cICA in MRCP detection with respect to previously proposed EEG filtering approaches.

  20. The Direct Imaging Search for Earth 2.0: Quantifying Biases and Planetary False Positives

    NASA Astrophysics Data System (ADS)

    Guimond, Claire Marie; Cowan, Nicolas B.

    2018-06-01

    Direct imaging is likely the best way to characterize the atmospheres of Earth-sized exoplanets in the habitable zone of Sun-like stars. Previously, Stark et al. estimated the Earth twin yield of future direct imaging missions, such as LUVOIR and HabEx. We extend this analysis to other types of planets, which will act as false positives for Earth twins. We define an Earth twin as any exoplanet within half an e-folding of 1 au in semimajor axis and 1 {R}\\oplus in planetary radius, orbiting a G-dwarf. Using Monte Carlo analyses, we quantify the biases and planetary false-positive rates of Earth searches. That is, given a pale dot at the correct projected separation and brightness to be a candidate Earth, what are the odds that it is, in fact, an Earth twin? Our notional telescope has a diameter of 10 m, an inner working angle of 3λ/D, and an outer working angle of 10λ/D (62 mas and 206 mas at 1.0 μm). With no precursor knowledge and one visit per star, 77% of detected candidate Earths are actually un-Earths; their mean radius is 2.3 {R}\\oplus , a sub-Neptune. The odds improve if we image every planet at its optimal orbital phase, either by relying on precursor knowledge, or by performing multi-epoch direct imaging. In such a targeted search, 47% of detected Earth twin candidates are false positives, and they have a mean radius of 1.7 {R}\\oplus . The false-positive rate is insensitive to stellar spectral type and the assumption of circular orbits.

  1. Unobtrusive monitoring of heart rate using a cost-effective speckle-based SI-POF remote sensor

    NASA Astrophysics Data System (ADS)

    Pinzón, P. J.; Montero, D. S.; Tapetado, A.; Vázquez, C.

    2017-03-01

    A novel speckle-based sensing technique for cost-effective heart-rate monitoring is demonstrated. This technique detects periodical changes in the spatial distribution of energy on the speckle pattern at the output of a Step-Index Polymer Optical Fiber (SI-POF) lead by using a low-cost webcam. The scheme operates in reflective configuration thus performing a centralized interrogation unit scheme. The prototype has been integrated into a mattress and its functionality has been tested with 5 different patients lying on the mattress in different positions without direct contact with the fiber sensing lead.

  2. Diazonium-functionalized horseradish peroxidase immobilized via addressable electrodeposition: direct electron transfer and electrochemical detection.

    PubMed

    Polsky, Ronen; Harper, Jason C; Dirk, Shawn M; Arango, Dulce C; Wheeler, David R; Brozik, Susan M

    2007-01-16

    A simple one-step procedure is introduced for the preparation of diazonium-enzyme adducts. The direct electrically addressable deposition of diazonium-modified enzymes is examined for electrochemical sensor applications. The deposition of diazonium-horseradish peroxidase leads to the direct electron transfer between the enzyme and electrode exhibiting a heterogeneous rate constant, ks, of 10.3 +/- 0.7 s-1 and a DeltaEp of 8 mV (v = 150 mV/s). The large ks and low DeltaEp are attributed to the intimate contact between enzyme and electrode attached by one to three phenyl molecules. Such an electrode shows high nonmediated catalytic activity toward H2O2 reduction. Future generations of arrayed electrochemical sensors and studies of direct electron transfer of enzymes can benefit from protein electrodes prepared by this method.

  3. Decision Processes in Discrimination: Fundamental Misrepresentations of Signal Detection Theory

    NASA Technical Reports Server (NTRS)

    Balakrishnan, J. D.

    1998-01-01

    In the first part of this article, I describe a new approach to studying decision making in discrimination tasks that does not depend on the technical assumptions of signal detection theory (e.g., normality of the encoding distributions). Applying these new distribution-free tests to data from three experiments, I show that base rate and payoff manipulations had substantial effects on the participants' encoding distributions but no effect on their decision rules, which were uniformly unbiased in equal and unequal base rate conditions and in symmetric and asymmetric payoff conditions. In the second part of the article, I show that this seemingly paradoxical result is readily explained by the sequential sampling models of discrimination. I then propose a new, "model-free" test for response bias that seems to more properly identify both the nature and direction of the biases induced by the classical bias manipulations.

  4. Rapid mapping of polarization switching through complete information acquisition

    NASA Astrophysics Data System (ADS)

    Somnath, Suhas; Belianinov, Alex; Kalinin, Sergei V.; Jesse, Stephen

    2016-12-01

    Polarization switching in ferroelectric and multiferroic materials underpins a broad range of current and emergent applications, ranging from random access memories to field-effect transistors, and tunnelling devices. Switching in these materials is exquisitely sensitive to local defects and microstructure on the nanometre scale, necessitating spatially resolved high-resolution studies of these phenomena. Classical piezoresponse force microscopy and spectroscopy, although providing necessary spatial resolution, are fundamentally limited in data acquisition rates and energy resolution. This limitation stems from their two-tiered measurement protocol that combines slow (~1 s) switching and fast (~10 kHz-1 MHz) detection waveforms. Here we develop an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias. This approach, facilitated by high-sensitivity electronics and adaptive filtering, enables spectroscopic imaging at a rate 3,504 times faster the current state of the art, achieving high-veracity imaging of polarization dynamics in complex microstructures.

  5. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    NASA Technical Reports Server (NTRS)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

  6. Fast Shear Compounding Using Robust Two-dimensional Shear Wave Speed Calculation and Multi-directional Filtering

    PubMed Central

    Song, Pengfei; Manduca, Armando; Zhao, Heng; Urban, Matthew W.; Greenleaf, James F.; Chen, Shigao

    2014-01-01

    A fast shear compounding method was developed in this study using only one shear wave push-detect cycle, such that the shear wave imaging frame rate is preserved and motion artifacts are minimized. The proposed method is composed of the following steps: 1. applying a comb-push to produce multiple differently angled shear waves at different spatial locations simultaneously; 2. decomposing the complex shear wave field into individual shear wave fields with differently oriented shear waves using a multi-directional filter; 3. using a robust two-dimensional (2D) shear wave speed calculation to reconstruct 2D shear elasticity maps from each filter direction; 4. compounding these 2D maps from different directions into a final map. An inclusion phantom study showed that the fast shear compounding method could achieve comparable performance to conventional shear compounding without sacrificing the imaging frame rate. A multi-inclusion phantom experiment showed that the fast shear compounding method could provide a full field-of-view (FOV), 2D, and compounded shear elasticity map with three types of inclusions clearly resolved and stiffness measurements showing excellent agreement to the nominal values. PMID:24613636

  7. Capacitance-level/density monitor for fluidized-bed combustor

    DOEpatents

    Fasching, George E.; Utt, Carroll E.

    1982-01-01

    A multiple segment three-terminal type capacitance probe with segment selection, capacitance detection and compensation circuitry and read-out control for level/density measurements in a fluidized-bed vessel is provided. The probe is driven at a high excitation frequency of up to 50 kHz to sense quadrature (capacitive) current related to probe/vessel capacitance while being relatively insensitive to the resistance current component. Compensation circuitry is provided for generating a negative current of equal magnitude to cancel out only the resistive component current. Clock-operated control circuitry separately selects the probe segments in a predetermined order for detecting and storing this capacitance measurement. The selected segment acts as a guarded electrode and is connected to the read-out circuitry while all unselected segments are connected to the probe body, which together form the probe guard electrode. The selected probe segment capacitance component signal is directed to a corresponding segment channel sample and hold circuit dedicated to that segment to store the signal derived from that segment. This provides parallel outputs for display, computer input, etc., for the detected capacitance values. The rate of segment sampling may be varied to either monitor the dynamic density profile of the bed (high sampling rate) or monitor average bed characteristics (slower sampling rate).

  8. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion.

    PubMed

    Homa, Dereje; Haile, Ermias; Washe, Alemayehu P

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant ( P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials.

  9. Single-visit approach of cervical cancer screening: See and Treat in Indonesia

    PubMed Central

    Vet, J N I; Kooijman, J L; Henderson, F C; Aziz, F M; Purwoto, G; Susanto, H; Surya, I G D; Budiningsih, S; Cornain, S; Fleuren, G J; Trimbos, J B; Peters, A A W

    2012-01-01

    Background: We performed a cross-sectional study in Indonesia to evaluate the performance of a single-visit approach of cervical cancer screening, using visual inspection with acetic acid (VIA), histology and cryotherapy in low-resource settings. Methods: Women having limited access to health-care facilities were screened by trained doctors using VIA. If the test was positive, biopsies were taken and when eligible, women were directly treated with cryotherapy. Follow-up was performed with VIA and cytology after 6 months. When cervical cancer was suspected or diagnosed, women were referred. The positivity rate, positive predictive value (PPV) and approximate specificity of the VIA test were calculated. The detection rate for cervical lesions was given. Results: Screening results were completed in 22 040 women, of whom 92.7% had never been screened. Visual inspection with acetic acid was positive in 4.4%. The PPV of VIA to detect CIN I or greater and CIN II or greater was 58.7% and 29.7%, respectively. The approximate specificity was 98.1%, and the detection rate for CIN I or greater was 2.6%. Conclusion: The single-visit approach cervical cancer screening performed well, showing See and Treat is a promising way to reduce cervical cancer in Indonesia. PMID:22850550

  10. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion

    PubMed Central

    Homa, Dereje; Haile, Ermias

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant (P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials. PMID:28469950

  11. Probabilistic approach to lysozyme crystal nucleation kinetics.

    PubMed

    Dimitrov, Ivaylo L; Hodzhaoglu, Feyzim V; Koleva, Dobryana P

    2015-09-01

    Nucleation of lysozyme crystals in quiescent solutions at a regime of progressive nucleation is investigated under an optical microscope at conditions of constant supersaturation. A method based on the stochastic nature of crystal nucleation and using discrete time sampling of small solution volumes for the presence or absence of detectable crystals is developed. It allows probabilities for crystal detection to be experimentally estimated. One hundred single samplings were used for each probability determination for 18 time intervals and six lysozyme concentrations. Fitting of a particular probability function to experimentally obtained data made possible the direct evaluation of stationary rates for lysozyme crystal nucleation, the time for growth of supernuclei to a detectable size and probability distribution of nucleation times. Obtained stationary nucleation rates were then used for the calculation of other nucleation parameters, such as the kinetic nucleation factor, nucleus size, work for nucleus formation and effective specific surface energy of the nucleus. The experimental method itself is simple and adaptable and can be used for crystal nucleation studies of arbitrary soluble substances with known solubility at particular solution conditions.

  12. Use of nonpathogenic, green fluorescent protein-marked Escherichia coli Biotype I cultures to evaluate the self-cleansing capabilities of a commercial beef grinding system after a contamination event.

    PubMed

    Wages, Jennifer A; Williams, Jennifer; Adams, Jacquelyn; George, Bruce; Oxford, Eric; Zelenka, Dan

    2014-11-01

    Inoculated beef trim containing a cocktail of green fluorescent protein-marked Escherichia coli biotype I cultures as surrogates for E. coli O157:H7 was introduced into two large, commercial grinding facilities capable of producing 180,000 kg of ground product in 1 day. Three repetitions were performed over 3 days. Sampling occurred at three different points within the process: postprimary grind, postsecondary grind-blender, and postpackaging. Resulting data show that, as the inoculated meat passes through the system, the presence of the marked surrogate quickly diminishes. The depletion rates are directly related to the amount of product in kilograms (represented by time) that has passed through the system, but these rates vary with each step of the process. The primary grinder appears to rid itself of the contaminant the most quickly; in all repetitions, the contaminant was not detected within 5 min of introduction of the contaminated combo bin into the system, which in all cases, was prior to the introduction of a second combo bin and within 1,800 kg of product. After the blending step and subsequent secondary grinding, the contaminant was detected in product produced from both the parent combo and the combo bin added directly after the parent combo bin; however, for those days on which three combo bins (approximately 2,700 kg) were available for sampling, the contaminant was not detected from product representing the third combo bin. Similarly, at the packaging step, the contaminant was detected in the product produced by both the parent and second combo bins; however, on those days when a third combo bin was available for sampling (repetitions 2 and 3), the contaminant was not detected from product produced from the third combo bin.

  13. Transient dynamics of invasive competition: barred owls, spotted owls, habitat, and the demons of competition present.

    PubMed

    Dugger, Katie M; Anthony, Robert G; Andrews, Lawrence S

    2011-10-01

    The recent range expansion of Barred Owls (Strix varia) into the Pacific Northwest, where the species now co-occurs with the endemic Northern Spotted Owl (Strix occidentalis caurina), resulted in a unique opportunity to investigate potential competition between two congeneric, previously allopatric species. The primary criticism of early competition research was the use of current species' distribution patterns to infer past processes; however, the recent expansion of the Barred Owl and the ability to model the processes that result in site occupancy (i.e., colonization and extinction) allowed us to address the competitive process directly rather than inferring past processes through current patterns. The purpose of our study was to determine whether Barred Owls had any negative effects on occupancy dynamics of nesting territories by Northern Spotted Owls and how these effects were influenced by habitat characteristics of Spotted Owl territories. We used single-species, multi-season occupancy models and covariates quantifying Barred Owl detections and habitat characteristics to model extinction and colonization rates of Spotted Owl pairs in southern Oregon, USA. We observed a strong, negative association between Barred Owl detections and colonization rates and a strong positive effect of Barred Owl detections on extinction rates of Spotted Owls. We observed increased extinction rates in response to decreased amounts of old forest at the territory core and higher colonization rates when old-forest habitat was less fragmented. Annual site occupancy for pairs reflected the strong effects of Barred Owls on occupancy dynamics with much lower occupancy rates predicted for territories where Barred Owls were detected. The strong Barred Owl and habitat effects on occupancy dynamics of Spotted Owls provided evidence of interference competition between the species. These effects increase the importance of conserving large amounts of contiguous, old-forest habitat to maintain Northern Spotted Owls in the landscape.

  14. Multiwavelength Follow-up of a Rare Icecube Neutrino Multiplet

    NASA Technical Reports Server (NTRS)

    Kocevski, Daniel

    2017-01-01

    IceCube detected three neutrino-induced track events arriving within less than 100s from a similar direction. Expected chance occurrence rate of 1 every 14 years, so not exceptionally rare, but interesting. If astrophysical in nature, the source would have to be relatively nearby or be an exceptional bright neutrino emitter. Follow-up observations by Swift-BAT, Swift-XRT, Master, ASAS-SN, LCOG, Veritas, FACT, and HAWC. The IceCube collaboration wanted to produce a paper summarizing the non-detections and outlining the follow-up network they have assembled. We were asked by Anna Franckowiak to contribute Fermi analysis to their write-up of this event.

  15. Detecting Single-Nucleotides by Tunneling Current Measurements at Sub-MHz Temporal Resolution.

    PubMed

    Morikawa, Takanori; Yokota, Kazumichi; Tanimoto, Sachie; Tsutsui, Makusu; Taniguchi, Masateru

    2017-04-18

    Label-free detection of single-nucleotides was performed by fast tunneling current measurements in a polar solvent at 1 MHz sampling rate using SiO₂-protected Au nanoprobes. Short current spikes were observed, suggestive of trapping/detrapping of individual nucleotides between the nanoelectrodes. The fall and rise features of the electrical signatures indicated signal retardation by capacitance effects with a time constant of about 10 microseconds. The high temporal resolution revealed current fluctuations, reflecting the molecular conformation degrees of freedom in the electrode gap. The method presented in this work may enable direct characterizations of dynamic changes in single-molecule conformations in an electrode gap in liquid.

  16. Quantification of astaxanthin in shrimp waste hydrolysate by HPLC.

    PubMed

    López-Cervantes, J; Sánchez-Machado, D I; Gutiérrez-Coronado, M A; Ríos-Vázquez, N J

    2006-10-01

    In the present study, a simple and rapid reversed-phase HPLC method for the determination of astaxanthin in shrimp waste hydrolysate has been developed and validated. The analytical procedure involves the direct extraction of astaxanthin from the lipid fraction with methanol. The analytical column, SS Exil ODS, was operated at 25C. The mobile phase consisted of a mixture of water:methanol:dichloromethane:acetonitrile (4.5:28:22:45.5 v/v/v/v) at a flow rate of 1.0 mL/min. Detection and identification were performed using a photodiode array detector (lambda(detection) = 476 nm). The proposed HPLC method showed adequate linearity, repeatability and accuracy.

  17. Genetic Local Search for Optimum Multiuser Detection Problem in DS-CDMA Systems

    NASA Astrophysics Data System (ADS)

    Wang, Shaowei; Ji, Xiaoyong

    Optimum multiuser detection (OMD) in direct-sequence code-division multiple access (DS-CDMA) systems is an NP-complete problem. In this paper, we present a genetic local search algorithm, which consists of an evolution strategy framework and a local improvement procedure. The evolution strategy searches the space of feasible, locally optimal solutions only. A fast iterated local search algorithm, which employs the proprietary characteristics of the OMD problem, produces local optima with great efficiency. Computer simulations show the bit error rate (BER) performance of the GLS outperforms other multiuser detectors in all cases discussed. The computation time is polynomial complexity in the number of users.

  18. Marine Targets Classification in PolInSAR Data

    NASA Astrophysics Data System (ADS)

    Chen, Peng; Yang, Jingsong; Ren, Lin

    2014-11-01

    In this paper, marine stationary targets and moving targets are studied by Pol-In-SAR data of Radarsat-2. A new method of stationary targets detection is proposed. The method get the correlation coefficient image of the In-SAR data, and using the histogram of correlation coefficient image. Then, A Constant False Alarm Rate (CFAR) algorithm and The Probabilistic Neural Network model are imported to detect stationary targets. To find the moving targets, Azimuth Ambiguity is show as an important feature. We use the length of azimuth ambiguity to get the target's moving direction and speed. Make further efforts, Targets classification is studied by rebuild the surface elevation of marine targets.

  19. Marine Targets Classification in PolInSAR Data

    NASA Astrophysics Data System (ADS)

    Chen, Peng; Yang, Jingsong; Ren, Lin

    2014-11-01

    In this paper, marine stationary targets and moving targets are studied by Pol-In-SAR data of Radarsat-2. A new method of stationary targets detection is proposed. The method get the correlation coefficient image of the In-SAR data, and using the histogram of correlation coefficient image. Then , A Constant False Alarm Rate (CFAR) algorithm and The Probabilistic Neural Network model are imported to detect stationary targets. To find the moving targets, Azimuth Ambiguity is show as an important feature. We use the length of azimuth ambiguity to get the target's moving direction and speed. Make further efforts, Targets classification is studied by rebuild the surface elevation of marine targets.

  20. Monitoring the enzymatic conversion of urea to ammonium by conventional or microchip capillary electrophoresis with contactless conductivity detection.

    PubMed

    Schuchert-Shi, Aiping; Hauser, Peter C

    2008-05-15

    Capillary electrophoresis with contactless conductivity detection was used to directly quantify the ammonium produced in the enzymatic conversion of urea with urease. This allowed the characterization of the reaction without having to use more elaborate indirect optical methods for quantification. The maximum rate of reaction, V(max), was determined as 5.1 mmol x mL(-1) x min(-1), and the Michaelis-Menten constant, K(m), was determined as 16 mM. Furthermore, the method was successfully applied to the determination of urea in clinical samples of human blood by using a conventional capillary and a microchip device.

  1. A model of directional selection applied to the evolution of drug resistance in HIV-1.

    PubMed

    Seoighe, Cathal; Ketwaroo, Farahnaz; Pillay, Visva; Scheffler, Konrad; Wood, Natasha; Duffet, Rodger; Zvelebil, Marketa; Martinson, Neil; McIntyre, James; Morris, Lynn; Hide, Winston

    2007-04-01

    Understanding how pathogens acquire resistance to drugs is important for the design of treatment strategies, particularly for rapidly evolving viruses such as HIV-1. Drug treatment can exert strong selective pressures and sites within targeted genes that confer resistance frequently evolve far more rapidly than the neutral rate. Rapid evolution at sites that confer resistance to drugs can be used to help elucidate the mechanisms of evolution of drug resistance and to discover or corroborate novel resistance mutations. We have implemented standard maximum likelihood methods that are used to detect diversifying selection and adapted them for use with serially sampled reverse transcriptase (RT) coding sequences isolated from a group of 300 HIV-1 subtype C-infected women before and after single-dose nevirapine (sdNVP) to prevent mother-to-child transmission. We have also extended the standard models of codon evolution for application to the detection of directional selection. Through simulation, we show that the directional selection model can provide a substantial improvement in sensitivity over models of diversifying selection. Five of the sites within the RT gene that are known to harbor mutations that confer resistance to nevirapine (NVP) strongly supported the directional selection model. There was no evidence that other mutations that are known to confer NVP resistance were selected in this cohort. The directional selection model, applied to serially sampled sequences, also had more power than the diversifying selection model to detect selection resulting from factors other than drug resistance. Because inference of selection from serial samples is unlikely to be adversely affected by recombination, the methods we describe may have general applicability to the analysis of positive selection affecting recombining coding sequences when serially sampled data are available.

  2. Rapid Detection of Staphylococcus aureus and Methicillin-Resistant S. aureus in Atopic Dermatitis by Using the BD Max StaphSR Assay.

    PubMed

    Lee, Mi Kyung; Park, Kui Young; Jin, Taewon; Kim, Ju Hee; Seo, Seong Jun

    2017-07-01

    Eczematous lesions of atopic dermatitis (AD) patients are known to be a source of Staphylococcus aureus (SA) transmission and might be a reservoir for community-associated methicillin-resistant SA (MRSA). The BD Max StaphSR (BD-SR) is a fully automated, multiplex real-time PCR assay for the direct detection and differentiation of SA and MRSA from nasal swab samples. We evaluated the detection rates of SA and MRSA from skin lesions of outpatients with AD using the BD-SR assay, and determined the usefulness of the BD-SR assay. A total of 244 skin swab samples (skin lesions of 213 outpatients with AD and normal skin of 31 healthy controls) were tested directly by using the BD-SR assay. Of the 213 samples from patients with AD, 69 (32.4%) were positive for SA, 6 (8.7%) of which were positive for MRSA. Only 1 (3.2%) of 31 samples from healthy controls was positive for SA. The BD-SR assay is effective for the rapid detection of SA and MRSA from skin swab samples, which can provide important information for managing patients with AD and preventing the spread of MRSA. © The Korean Society for Laboratory Medicine.

  3. Indirect detection of radiation sources through direct detection of radiolysis products

    DOEpatents

    Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA

    2010-04-20

    A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

  4. Method and apparatus for measuring enrichment of UF6

    DOEpatents

    Hill, Thomas Roy [Santa Fe, NM; Ianakiev, Kiril Dimitrov [Los Alamos, NM

    2011-06-07

    A system and method are disclosed for determining the enrichment of .sup.235U in Uranium Hexafluoride (UF6) utilizing synthesized X-rays which are directed at a container test zone containing a sample of UF6. A detector placed behind the container test zone then detects and counts the X-rays which pass through the container and the UF6. In order to determine the portion of the attenuation due to the UF6 gas alone, this count rate may then be compared to a calibration count rate of X-rays passing through a calibration test zone which contains a vacuum, the test zone having experienced substantially similar environmental conditions as the actual test zone. Alternatively, X-rays of two differing energy levels may be alternately directed at the container, where either the container or the UF6 has a high sensitivity to the difference in the energy levels, and the other having a low sensitivity.

  5. Monitoring probe for groundwater flow

    DOEpatents

    Looney, Brian B.; Ballard, Sanford

    1994-01-01

    A monitoring probe for detecting groundwater migration. The monitor features a cylinder made of a permeable membrane carrying an array of electrical conductivity sensors on its outer surface. The cylinder is filled with a fluid that has a conductivity different than the groundwater. The probe is placed in the ground at an area of interest to be monitored. The fluid, typically saltwater, diffuses through the permeable membrane into the groundwater. The flow of groundwater passing around the permeable membrane walls of the cylinder carries the conductive fluid in the same general direction and distorts the conductivity field measured by the sensors. The degree of distortion from top to bottom and around the probe is precisely related to the vertical and horizontal flow rates, respectively. The electrical conductivities measured by the sensors about the outer surface of the probe are analyzed to determine the rate and direction of the groundwater flow.

  6. Monitoring probe for groundwater flow

    DOEpatents

    Looney, B.B.; Ballard, S.

    1994-08-23

    A monitoring probe for detecting groundwater migration is disclosed. The monitor features a cylinder made of a permeable membrane carrying an array of electrical conductivity sensors on its outer surface. The cylinder is filled with a fluid that has a conductivity different than the groundwater. The probe is placed in the ground at an area of interest to be monitored. The fluid, typically saltwater, diffuses through the permeable membrane into the groundwater. The flow of groundwater passing around the permeable membrane walls of the cylinder carries the conductive fluid in the same general direction and distorts the conductivity field measured by the sensors. The degree of distortion from top to bottom and around the probe is precisely related to the vertical and horizontal flow rates, respectively. The electrical conductivities measured by the sensors about the outer surface of the probe are analyzed to determine the rate and direction of the groundwater flow. 4 figs.

  7. Detection of disseminated peritoneal tumors by fluorescein diacrylate in mice

    NASA Astrophysics Data System (ADS)

    Harada, Yoshinori; Furuta, Hirokazu; Murayama, Yasutoshi; Dai, Ping; Fujikawa, Yuta; Urano, Yasuteru; Nagano, Tetsuo; Morishita, Koki; Hasegawa, Akira; Takamatsu, Tetsuro

    2009-02-01

    Tumor invasion to the peritoneum is a poor prognostic factor in cancer patients. Accurate diagnosis of disseminated peritoneal tumors is essential to accurate cancer staging. To date, peritoneal washing cytology during laparotomy has been used for diagnosis of peritoneal dissemination of gastrointestinal cancer, but its sensitivity has not been satisfactory. Thus, a more direct approach is indispensable to detect peritoneal dissemination in vivo. Fluorescein diacrylate (FDAcr) is an esterase-sensitive fluorescent probe derived from fluorescein. In cancer cells, fluorescent fluorescein generated by exogenous application of FDAcr selectively deposits owing to its stronger hydrolytic enzyme activity and its lower leakage rate. We examined whether FDAcr can specifically detect disseminated peritoneal tumors in athymic nude mouse models. Intraperitoneally administered FDAcr revealed disseminated peritoneal microscopic tumors not readily recognized on white-light imaging. These results suggest that FDAcr is a useful probe for detecting disseminated peritoneal tumors.

  8. Liquid biopsy on chip: a paradigm shift towards the understanding of cancer metastasis.

    PubMed

    Tadimety, Amogha; Syed, Abeer; Nie, Yuan; Long, Christina R; Kready, Kasia M; Zhang, John X J

    2017-01-23

    This comprehensive review serves as a guide for developing scalable and robust liquid biopsies on chip for capture, detection, and analysis of circulating tumor cells (CTCs). Liquid biopsy, the detection of biomarkers from body fluids, has proven challenging because of CTC rarity and the heterogeneity of CTCs shed from tumors. The review starts with the underlying biological mechanisms that make liquid biopsy a challenge before moving into an evaluation of current technological progress. Then, a framework for evaluation of the technologies is presented with special attention to throughput, capture rate, and cell viability for analysis. Technologies for CTC capture, detection, and analysis will be evaluated based on these criteria, with a focus on current approaches, limitations and future directions. The paper provides a critical review for microchip developers as well as clinical investigators to build upon the existing progress towards the goal of designing CTC capture, detection, and analysis platforms.

  9. Flexible Piezoelectric Sensor-Based Gait Recognition.

    PubMed

    Cha, Youngsu; Kim, Hojoon; Kim, Doik

    2018-02-05

    Most motion recognition research has required tight-fitting suits for precise sensing. However, tight-suit systems have difficulty adapting to real applications, because people normally wear loose clothes. In this paper, we propose a gait recognition system with flexible piezoelectric sensors in loose clothing. The gait recognition system does not directly sense lower-body angles. It does, however, detect the transition between standing and walking. Specifically, we use the signals from the flexible sensors attached to the knee and hip parts on loose pants. We detect the periodic motion component using the discrete time Fourier series from the signal during walking. We adapt the gait detection method to a real-time patient motion and posture monitoring system. In the monitoring system, the gait recognition operates well. Finally, we test the gait recognition system with 10 subjects, for which the proposed system successfully detects walking with a success rate over 93 %.

  10. Analysis of phosphorothionate pesticides using a chloroperoxidase pretreatment and acetylcholinesterase biosensor detection.

    PubMed

    Roepcke, Clarisse B S; Muench, Susanne B; Schulze, Holger; Bachmann, Till T; Bachmann, Till; Schmid, Rolf D; Hauer, Bernhard

    2010-08-11

    Acetylcholinesterase (AChE) is responsible for the hydrolysis of acetylcholine in the nervous system. It is inhibited by organophosphate and carbamate pesticides. However, this enzyme is only slightly inhibited by organophosphorothionates, which makes the detection of these pesticides analytically very difficult. A new enzymatic method for the activation and detection of phosphorothionates was developed with the capability to be used directly in food samples without the need of laborious solvent extraction steps. Chloroperoxidase (CPO) from Caldariomyces fumago was combined with tert-butyl hydroperoxide and two halides. Chlorpyrifos and triazophos were completely oxidized. Fenitrothion, methidathion and parathion methyl showed conversion rates between 54 and 61%. Furthermore, the oxidized solution was submitted to an AChE biosensor assay. Chlorpyrifos spiked in organic orange juice was oxidized, where its oxon product was detected in concentrations down to 5 microg/L (final concentration food sample: 25 microg/L). The complete duration of the method takes about 2 h.

  11. Leaf area index, biomass carbon and growth rate of radiata pine genetic types and relationships with LiDAR

    Treesearch

    Peter N. Beets; Stephen Reutebuch; Mark O. Kimberley; Graeme R. Oliver; Stephen H. Pearce; Robert J. McGaughey

    2011-01-01

    Relationships between discrete-return light detection and ranging (LiDAR) data and radiata pine leaf area index (LAI), stem volume, above ground carbon, and carbon sequestration were developed using 10 plots with directly measured biomass and leaf area data, and 36 plots with modelled carbon data. The plots included a range of genetic types established on north- and...

  12. Monitoring the emergence of community transmission of influenza A/H1N1 2009 in England: a cross sectional opportunistic survey of self sampled telephone callers to NHS Direct.

    PubMed

    Elliot, Alex J; Powers, Cassandra; Thornton, Alicia; Obi, Chinelo; Hill, Caterina; Simms, Ian; Waight, Pauline; Maguire, Helen; Foord, David; Povey, Enid; Wreghitt, Tim; Goddard, Nichola; Ellis, Joanna; Bermingham, Alison; Sebastianpillai, Praveen; Lackenby, Angie; Zambon, Maria; Brown, David; Smith, Gillian E; Gill, O Noel

    2009-08-27

    To evaluate ascertainment of the onset of community transmission of influenza A/H1N1 2009 (swine flu) in England during the earliest phase of the epidemic through comparing data from two surveillance systems. Cross sectional opportunistic survey. Results from self samples by consenting patients who had called the NHS Direct telephone health line with cold or flu symptoms, or both, and results from Health Protection Agency (HPA) regional microbiology laboratories on patients tested according to the clinical algorithm for the management of suspected cases of swine flu. Six regions of England between 24 May and 30 June 2009. Proportion of specimens with laboratory evidence of influenza A/H1N1 2009. Influenza A/H1N1 2009 infections were detected in 91 (7%) of the 1385 self sampled specimens tested. In addition, eight instances of influenza A/H3 infection and two cases of influenza B infection were detected. The weekly rate of change in the proportions of infected individuals according to self obtained samples closely matched the rate of increase in the proportions of infected people reported by HPA regional laboratories. Comparing the data from both systems showed that local community transmission was occurring in London and the West Midlands once HPA regional laboratories began detecting 100 or more influenza A/H1N1 2009 infections, or a proportion positive of over 20% of those tested, each week. Trends in the proportion of patients with influenza A/H1N1 2009 across regions detected through clinical management were mirrored by the proportion of NHS Direct callers with laboratory confirmed infection. The initial concern that information from HPA regional laboratory reports would be too limited because it was based on testing patients with either travel associated risk or who were contacts of other influenza cases was unfounded. Reports from HPA regional laboratories could be used to recognise the extent to which local community transmission was occurring.

  13. VisNAV 100: a robust, compact imaging sensor for enabling autonomous air-to-air refueling of aircraft and unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Katake, Anup; Choi, Heeyoul

    2010-01-01

    To enable autonomous air-to-refueling of manned and unmanned vehicles a robust high speed relative navigation sensor capable of proving high accuracy 3DOF information in diverse operating conditions is required. To help address this problem, StarVision Technologies Inc. has been developing a compact, high update rate (100Hz), wide field-of-view (90deg) direction and range estimation imaging sensor called VisNAV 100. The sensor is fully autonomous requiring no communication from the tanker aircraft and contains high reliability embedded avionics to provide range, azimuth, elevation (3 degrees of freedom solution 3DOF) and closing speed relative to the tanker aircraft. The sensor is capable of providing 3DOF with an error of 1% in range and 0.1deg in azimuth/elevation up to a range of 30m and 1 deg error in direction for ranges up to 200m at 100Hz update rates. In this paper we will discuss the algorithms that were developed in-house to enable robust beacon pattern detection, outlier rejection and 3DOF estimation in adverse conditions and present the results of several outdoor tests. Results from the long range single beacon detection tests will also be discussed.

  14. Welding studs detection based on line structured light

    NASA Astrophysics Data System (ADS)

    Geng, Lei; Wang, Jia; Wang, Wen; Xiao, Zhitao

    2018-01-01

    The quality of welding studs is significant for installation and localization of components of car in the process of automobile general assembly. A welding stud detection method based on line structured light is proposed. Firstly, the adaptive threshold is designed to calculate the binary images. Then, the light stripes of the image are extracted after skeleton line extraction and morphological filtering. The direction vector of the main light stripe is calculated using the length of the light stripe. Finally, the gray projections along the orientation of the main light stripe and the vertical orientation of the main light stripe are computed to obtain curves of gray projection, which are used to detect the studs. Experimental results demonstrate that the error rate of proposed method is lower than 0.1%, which is applied for automobile manufacturing.

  15. The first gravitational-wave burst GW150914, as predicted by the scenario machine

    NASA Astrophysics Data System (ADS)

    Lipunov, V. M.; Kornilov, V.; Gorbovskoy, E.; Tiurina, N.; Balanutsa, P.; Kuznetsov, A.

    2017-02-01

    The Advanced LIGO observatory recently reported (Abbott et al., 2016a) the first direct detection of gravitational waves predicted by Einstein (1916). The detection of this event was predicted in 1997 on the basis of the Scenario Machine population synthesis calculations (Lipunov et al., 1997b) Now we discuss the parameters of binary black holes and event rates predicted by different scenarios of binary evolution. We give a simple explanation of the big difference between detected black hole masses and the mean black hole masses observed in of X-ray Nova systems. The proximity of the masses of the components of GW150914 is in good agreement with the observed initial mass ratio distribution in massive binary systems, as is used in Scenario Machine calculations for massive binaries.

  16. Quantum memory receiver for superadditive communication using binary coherent states

    NASA Astrophysics Data System (ADS)

    Klimek, Aleksandra; Jachura, Michał; Wasilewski, Wojciech; Banaszek, Konrad

    2016-11-01

    We propose a simple architecture based on multimode quantum memories for collective readout of classical information keyed using a pair coherent states, exemplified by the well-known binary phase shift keying format. Such a configuration enables demonstration of the superadditivity effect in classical communication over quantum channels, where the transmission rate becomes enhanced through joint detection applied to multiple channel uses. The proposed scheme relies on the recently introduced idea to prepare Hadamard sequences of input symbols that are mapped by a linear optical transformation onto the pulse position modulation format [Guha, S. Phys. Rev. Lett. 2011, 106, 240502]. We analyze two versions of readout based on direct detection and an optional Dolinar receiver which implements the minimum-error measurement for individual detection of a binary coherent state alphabet.

  17. Quantum memory receiver for superadditive communication using binary coherent states.

    PubMed

    Klimek, Aleksandra; Jachura, Michał; Wasilewski, Wojciech; Banaszek, Konrad

    2016-11-12

    We propose a simple architecture based on multimode quantum memories for collective readout of classical information keyed using a pair coherent states, exemplified by the well-known binary phase shift keying format. Such a configuration enables demonstration of the superadditivity effect in classical communication over quantum channels, where the transmission rate becomes enhanced through joint detection applied to multiple channel uses. The proposed scheme relies on the recently introduced idea to prepare Hadamard sequences of input symbols that are mapped by a linear optical transformation onto the pulse position modulation format [Guha, S. Phys. Rev. Lett. 2011 , 106 , 240502]. We analyze two versions of readout based on direct detection and an optional Dolinar receiver which implements the minimum-error measurement for individual detection of a binary coherent state alphabet.

  18. Research on intrusion detection based on Kohonen network and support vector machine

    NASA Astrophysics Data System (ADS)

    Shuai, Chunyan; Yang, Hengcheng; Gong, Zeweiyi

    2018-05-01

    In view of the problem of low detection accuracy and the long detection time of support vector machine, which directly applied to the network intrusion detection system. Optimization of SVM parameters can greatly improve the detection accuracy, but it can not be applied to high-speed network because of the long detection time. a method based on Kohonen neural network feature selection is proposed to reduce the optimization time of support vector machine parameters. Firstly, this paper is to calculate the weights of the KDD99 network intrusion data by Kohonen network and select feature by weight. Then, after the feature selection is completed, genetic algorithm (GA) and grid search method are used for parameter optimization to find the appropriate parameters and classify them by support vector machines. By comparing experiments, it is concluded that feature selection can reduce the time of parameter optimization, which has little influence on the accuracy of classification. The experiments suggest that the support vector machine can be used in the network intrusion detection system and reduce the missing rate.

  19. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    PubMed Central

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPRfalse-positive rate, sensitivity, and CDRcancer detection rate at all annual interpretive volumes. Conclusion These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow. © RSNA, 2014 Online supplemental material is available for this article. PMID:24960110

  20. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    PubMed

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPR false-positive rate (P = .011) and CDR cancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPR false-positive rate , sensitivity, and CDR cancer detection rate at all annual interpretive volumes. These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow.

  1. Direct characterization of quantum dynamics with noisy ancilla

    DOE PAGES

    Dumitrescu, Eugene F.; Humble, Travis S.

    2015-11-23

    We present methods for the direct characterization of quantum dynamics (DCQD) in which both the principal and ancilla systems undergo noisy processes. Using a concatenated error detection code, we discriminate between located and unlocated errors on the principal system in what amounts to filtering of ancilla noise. The example of composite noise involving amplitude damping and depolarizing channels is used to demonstrate the method, while we find the rate of noise filtering is more generally dependent on code distance. Furthermore our results indicate the accuracy of quantum process characterization can be greatly improved while remaining within reach of current experimentalmore » capabilities.« less

  2. Electro-optic measurement of terahertz pulse energy distribution.

    PubMed

    Sun, J H; Gallacher, J G; Brussaard, G J H; Lemos, N; Issac, R; Huang, Z X; Dias, J M; Jaroszynski, D A

    2009-11-01

    An accurate and direct measurement of the energy distribution of a low repetition rate terahertz electromagnetic pulse is challenging because of the lack of sensitive detectors in this spectral range. In this paper, we show how the total energy and energy density distribution of a terahertz electromagnetic pulse can be determined by directly measuring the absolute electric field amplitude and beam energy density distribution using electro-optic detection. This method has potential use as a routine method of measuring the energy density of terahertz pulses that could be applied to evaluating future high power terahertz sources, terahertz imaging, and spatially and temporarily resolved pump-probe experiments.

  3. Method and apparatus for measuring frequency and phase difference

    NASA Technical Reports Server (NTRS)

    Shores, Paul (Inventor); Lichtenberg, Christopher (Inventor); Kobayashi, Herbert S. (Inventor); Cunningham, Allen R. (Inventor)

    1986-01-01

    The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.

  4. Simplified Protocol for Carba NP Test for Enhanced Detection of Carbapenemase Producers Directly from Bacterial Cultures

    PubMed Central

    Pasteran, Fernando; Tijet, Nathalie; Melano, Roberto G.

    2015-01-01

    We compared carbapenemase detection among 266 Gram-negative bacilli (161 carbapenemase producers) using the Carba NP tests issued by the CLSI (CNPt-CLSI) and a novel protocol (CNPt-direct) designed for carbapenemase detection direct from bacterial cultures (instead of bacterial extracts required by the CLSI tests). The specificities were comparable (100%), but the CNPt-direct was more sensitive (98% versus 84%). The CNPt-direct was easier to perform due to the direct use of colonies and offered a more robust detection of carbapenemase producers. PMID:26424841

  5. Detection of JAK2 V617F mutation increases the diagnosis of myeloproliferative neoplasms

    PubMed Central

    ZHANG, SHU-PENG; LI, HUI; LAI, REN-SHENG

    2015-01-01

    The Janus kinase (JAK)2 gene, which is located on chromosome 9p24, is involved in the signaling transduction pathways of the hematopoietic and immune system. Mutations in the JAK2 gene have served as disease markers for myeloproliferative neoplasms (MPNs). The aim of the present study was to investigate the occurrence of the JAK2 gene mutation in 140 clinical samples, and to evaluate its clinical significance in MPNs and other hematological diseases. Genomic DNA was extracted from the peripheral blood leukocytes or bone marrow karyocytes of 140 clinical samples, which included 130 patients with various types of hematological disease and 10 control patients. In addition, exons 12 and 14 of the JAK2 gene were analyzed by direct sequencing and the mutation rates of various MPN subtypes were evaluated. Of the 140 samples, exons 12 and 14 were tested in 74 samples, however, exon 14 only was tested in 66 samples. No mutations were identified in exon 12. The V617F mutation rate in polycythemia vera was 82.1% (23/28), and the mutation rates in essential thrombocythemia histiocytosis, primary myelofibrosis and other MPNs were 53.1% (17/32), 40.0% (4/10) and 60.0% (6/10), respectively. Therefore, the total mutation rate of the JAK2 gene in MPN was 62.5% (50/80). For non-MPN hematological diseases, four V617F mutations were detected in samples of leukocytosis of unknown origin (4/12), however, no JAK2 V617F mutations were identified in the 10 controls. Therefore, JAK2 V617F mutations may present a novel marker for diagnosis of MPNs. Furthermore, the direct sequencing method appeared to be satisfactory for the clinical gene testing of hematological samples. PMID:25624900

  6. Detecting Adaptation in Protein-Coding Genes Using a Bayesian Site-Heterogeneous Mutation-Selection Codon Substitution Model.

    PubMed

    Rodrigue, Nicolas; Lartillot, Nicolas

    2017-01-01

    Codon substitution models have traditionally attempted to uncover signatures of adaptation within protein-coding genes by contrasting the rates of synonymous and non-synonymous substitutions. Another modeling approach, known as the mutation-selection framework, attempts to explicitly account for selective patterns at the amino acid level, with some approaches allowing for heterogeneity in these patterns across codon sites. Under such a model, substitutions at a given position occur at the neutral or nearly neutral rate when they are synonymous, or when they correspond to replacements between amino acids of similar fitness; substitutions from high to low (low to high) fitness amino acids have comparatively low (high) rates. Here, we study the use of such a mutation-selection framework as a null model for the detection of adaptation. Following previous works in this direction, we include a deviation parameter that has the effect of capturing the surplus, or deficit, in non-synonymous rates, relative to what would be expected under a mutation-selection modeling framework that includes a Dirichlet process approach to account for across-codon-site variation in amino acid fitness profiles. We use simulations, along with a few real data sets, to study the behavior of the approach, and find it to have good power with a low false-positive rate. Altogether, we emphasize the potential of recent mutation-selection models in the detection of adaptation, calling for further model refinements as well as large-scale applications. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  7. Direct Measurements of 3D Structure, Chemistry and Mass Density During the Induction Period of C3S Hydration

    PubMed Central

    Hu, Qinang; Aboustait, Mohammed; Kim, Taehwan; Ley, M. Tyler; Bullard, Jeffrey W.; Scherer, George; Hanan, Jay C.; Rose, Volker; Winarski, Robert; Gelb, Jeffrey

    2017-01-01

    The reasons for the start and end of the induction period of cement hydration remain topic of controversy. One long-standing hypothesis is that a thin metastable hydrate forming on the surface of cement grains significantly reduces the particle dissolution rate; the eventual disappearance of this layer re-establishes higher dissolution rates at the beginning of the acceleration period. However, the importance, or even the existence, of this metastable layer has been questioned because it cannot be directly detected in most experiments. In this work, a combined analysis using nano-tomography and nano-X-ray fluorescence makes the direct imaging of early hydration products possible. These novel X-ray imaging techniques provide quantitative measurements of 3D structure, chemical composition, and mass density of the hydration products during the induction period. This work does not observe a low density product on the surface of the particle, but does provide insights into the formation of etch pits and the subsequent hydration products that fill them. PMID:28919638

  8. [Tuberculosis control in Shinjuku Ward, Tokyo--promoting the DOTS program and its outcome].

    PubMed

    Kaguraoka, Sumi; Ohmori, Masako; Takao, Yoshiko; Yamada, Mari; Muroi, Masako; Nagamine, Michiko; Fukazawa, Keiji; Nagai, Megumi; Wada, Masako; Hoshino, Hitoshi; Yoshiyama, Takashi; Maeda, Hideo; Ishikawa, Nobukatsu

    2008-09-01

    The objectives were to report how to promote tuberculosis (TB) control including DOTS (Directly Observed Treatment, Short-course) programs, and to evaluate the results of TB control programs in Shinjuku Ward (Shinjuku-ku). SETTING AND CHARACTERISTICS: Inhabitants and TB patients in Shinjuku Ward. Shinjuku Ward is located in the center of metropolitan Tokyo and has typical urban TB problems, such as high incidence rate and TB among foreigners and the homeless. The TB incidence rates in Shinjuku Ward decreased from 83.9 per 100,000 population in 1999 to 42.5 per 100,000 population in 2006, however, the rates were still two times higher than the national average. Therefore, one of the important TB programs in Shinjuku has been to actively detect cases among high-risk groups such as foreigners and the homeless. We observed the trend of case detection rates by health examination with chest X-ray among different high-risk groups, and compared the treatment outcomes before and after DOTS program execution. We also reviewed the changes of re-treatment rates and drug resistance rates. The case detection rates of TB by health examinations of foreign students at Japanese language schools decreased from 0.49% in 1996 to 0.13% in 2006 (p = 0.021). Although the case detection rates decreased, they were still about 26 times higher than those of Japanese students. While, the case detection rates among the homeless remained high with 4.7%, 3.3%, 4.5% and 3.6% in 1999-2002, respectively, since 2003, however, they had decreased and no TB cases were detected in 2005-2006. The DOTS program for homeless TB patients has been carried out since 2000 and that for the foreigners since 2003. The rates of defaulting during treatment before DOTS were very high among both homeless patients (21.4%) and foreigners (29.8%) in 1998-1999. However, after the introduction of DOTS program, those rates declined to 10.4% (p = 0.014) among the homeless and 7.8% (p = 0.002) among foreigners in 2002-2004. The proportion of newly notified patients with previous TB treatment and those with multi-drug resistant TB (MDR-TB) have also decreased after the introduction of DOTS programs. From 2000-2002 to 2003-2006, the re-treatment rates decreased from 19.4% to 10.0% (p < 0.001) and MDR-TB rates decreased from 1.6% to 0.2% (p = 0.042), respectively. The key points of TB control in Shinjuku Ward are to detect TB cases early especially among the high-risk groups, and to assist all TB patients to complete their treatment. In order to expand this strategy, besides promoting active case findings among high-risk groups, we have developed many types of DOTS programs, considering each patient's lifestyle and cooperating with school teachers at schools, pharmacists at pharmacies, home-care specialists at homes or facilities for the elderly, and so on. Among others, a major premise for the homeless and some other socially disadvantaged patients was to guarantee the provision of medicine and living by introducing social welfare services, before starting DOTS programs. This approach might have helped to reduce the defaulting rate, relapse rate and MDR-TB rate.

  9. Body-size perception, body-esteem, and parenting history in college women reporting a history of child abuse.

    PubMed

    Eubanks, Jessica R; Kenkel, Michaela Y; Gardner, Rick M

    2006-04-01

    This study investigated the relations among physical, emotional, and sexual abuse up to adolescence and subsequent perception of body size, detection of changes in body size, and body-esteem. The role of parenting history in abused participants was also examined. 38 college undergraduate women, half of whom had been abused, reported instances of abuse, childhood parenting history, and current body-esteem. A recently developed software program of Gardner and Boice was used to present a series of distorted frontal profiles of each participant's own body for the women to rate as being too wide or too thin. A psychophysical procedure called adaptive probit estimation was used to measure the amount of over- and underestimation of these ratings and whether these changes were statistically significant. Analysis showed abused participants had distorted perceptions of body size, although the direction of the distortion was not consistent. There was no difference in detection of changes in body size. Abused and nonabused participants differed on measures of body-esteem and on ratings of most parenting experiences, including experiences with both mothers and fathers.

  10. Biological nitrogen fixation in the oxygen-minimum region of the eastern tropical North Pacific ocean.

    PubMed

    Jayakumar, Amal; Chang, Bonnie X; Widner, Brittany; Bernhardt, Peter; Mulholland, Margaret R; Ward, Bess B

    2017-10-01

    Biological nitrogen fixation (BNF) was investigated above and within the oxygen-depleted waters of the oxygen-minimum zone of the Eastern Tropical North Pacific Ocean. BNF rates were estimated using an isotope tracer method that overcame the uncertainty of the conventional bubble method by directly measuring the tracer enrichment during the incubations. Highest rates of BNF (~4 nM day -1 ) occurred in coastal surface waters and lowest detectable rates (~0.2 nM day -1 ) were found in the anoxic region of offshore stations. BNF was not detectable in most samples from oxygen-depleted waters. The composition of the N 2 -fixing assemblage was investigated by sequencing of nifH genes. The diazotrophic assemblage in surface waters contained mainly Proteobacterial sequences (Cluster I nifH), while both Proteobacterial sequences and sequences with high identities to those of anaerobic microbes characterized as Clusters III and IV type nifH sequences were found in the anoxic waters. Our results indicate modest input of N through BNF in oxygen-depleted zones mainly due to the activity of proteobacterial diazotrophs.

  11. Extracellular Enzymes Facilitate Electron Uptake in Biocorrosion and Bioelectrosynthesis

    PubMed Central

    Deutzmann, Jörg S.; Sahin, Merve

    2015-01-01

    ABSTRACT Direct, mediator-free transfer of electrons between a microbial cell and a solid phase in its surrounding environment has been suggested to be a widespread and ecologically significant process. The high rates of microbial electron uptake observed during microbially influenced corrosion of iron [Fe(0)] and during microbial electrosynthesis have been considered support for a direct electron uptake in these microbial processes. However, the underlying molecular mechanisms of direct electron uptake are unknown. We investigated the electron uptake characteristics of the Fe(0)-corroding and electromethanogenic archaeon Methanococcus maripaludis and discovered that free, surface-associated redox enzymes, such as hydrogenases and presumably formate dehydrogenases, are sufficient to mediate an apparent direct electron uptake. In genetic and biochemical experiments, we showed that these enzymes, which are released from cells during routine culturing, catalyze the formation of H2 or formate when sorbed to an appropriate redox-active surface. These low-molecular-weight products are rapidly consumed by M. maripaludis cells when present, thereby preventing their accumulation to any appreciable or even detectable level. Rates of H2 and formate formation by cell-free spent culture medium were sufficient to explain the observed rates of methane formation from Fe(0) and cathode-derived electrons by wild-type M. maripaludis as well as by a mutant strain carrying deletions in all catabolic hydrogenases. Our data collectively show that cell-derived free enzymes can mimic direct extracellular electron transfer during Fe(0) corrosion and microbial electrosynthesis and may represent an ecologically important but so far overlooked mechanism in biological electron transfer. PMID:25900658

  12. Bedload transport rates in a gravel bedded-river derived from high-resolution monitoring using seismic impact plates

    NASA Astrophysics Data System (ADS)

    Downs, Peter; Soar, Philip

    2015-04-01

    Accurate characterisation of bedload transport rates is critical for a better understanding of geomorphological process dynamics, aquatic habitats, sediment budgets and strategies for catchment-scale initiatives in sediment management under conditions of climate change. However, rate estimation is challenging in practice: direct measurements are costly and logistically difficult to achieve with acceptable accuracy over geomorphologically-relevant time periods, and the uncertainty in transport rates predicted from empirical formulae and numerical simulation is rarely below 50 per cent. Partly reflecting these issues, passive technologies for continuous bedload monitoring are becoming increasingly popular. Sensors such as seismic impact plates offer the opportunity to characterise bedload activity at exceptionally high resolution - monitoring from the River Avon, (Devon, UK) indicated that despite significant intra-event and between-plate differences in apparent bedload transport aggregated over 5-minute periods, the magnitude-frequency product of discharge and impact frequency result in a highly plausible effective discharge, supporting the potential value of impact plates as indicators of relative sediment transport loads over annual timescales. Whereas the focus in bedload rate estimation to date has been on developing satisfactory sediment rating curves from detection signals, we instead develop a method for directly estimating bedload transport rates from impact plate data as a function of intensity of transport (count, n, per second), bed material mass (kg) and cross-stream transport variability. Bulk sediment samples are converted to a mass in transit for each instantaneous discharge according to the intensity of transport and a Monte Carlo simulation of the load in transit determined at random from the bed material particle size distribution. The lower detection threshold is determined using experimental calibration and the upper size limit is determined from incipient motion estimates thereby establishing the fraction of transported material sensed by the plates. The lateral variability in transport rates across the cross-section is estimated empirically using multiple plates or by interpolation. This procedure provides a potentially affordable and robust method of achieving uncertainty-bound indicative measures of bedload transport with the potential for wide-ranging practical applications.

  13. Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit

    NASA Astrophysics Data System (ADS)

    Pan, Weicheng; Wu, Haodi; Luo, Jiajun; Deng, Zhenzhou; Ge, Cong; Chen, Chao; Jiang, Xiaowei; Yin, Wan-Jian; Niu, Guangda; Zhu, Lujun; Yin, Lixiao; Zhou, Ying; Xie, Qingguo; Ke, Xiaoxing; Sui, Manling; Tang, Jiang

    2017-11-01

    Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs2AgBiBr6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag+/Bi3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGyair s-1, comparable to the latest record of 0.036 μGyair s-1 using CH3NH3PbBr3 single crystals. Suppressed ion migration in Cs2AgBiBr6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit.

  14. Efficacy of four synchronization protocols on the estrus behavior and conception in native Korean cattle (Hanwoo).

    PubMed

    Lee, Myeung-Sik; Rahman, Md Saidur; Kwon, Woo-Sung; Chung, Hak-Jae; Yang, Boh-Suk; Pang, Myung-Geol

    2013-11-01

    Ineffective estrus detection is the foremost limiting factor in the fertility of farmed cattle worldwide. Failure to detect estrus or erroneous diagnosis of estrus results in great economic losses in Korea each year. This study was carried out in order to comprehensively describe the estrus behaviors and conception rates of different estrus synchronization protocols applied to 40 cycling native Korean cattle (Hanwoo). The cows were grouped into four (n = 10) and treated with the following protocols: (1) Day -15: controlled intravaginal drug-releasing device (CIDR) for 12 days; Day -5: prostaglandin F2α (PGF2α), (2) ovulation synchronization (OVS): Day -15: GnRH; Day -6: PGF2α; Day -4: GnRH, (3) Day -15: progesterone-releasing intravaginal device for 12 days; Day -5: PGF2α; and (4) Day -15: PGF2α; Day -4: PGF2α. Artificial insemination was performed 12 hours after the detection of estrus using frozen-thawed semen. Estrus signs were compared using a charge-coupled device camera (CCDC) and a control method (direct visual observation). The pregnancy of the cows was determined by transrectal ultrasonography at Days 25 to 30 postinsemination. The results indicated that the day of estrus return was significantly earlier using the CCDC method compared with direct visualization (P < 0.05). Mounting of other cows was the most predominant sign of estrus among the flock (P < 0.05), as analyzed using the CCDC. In the OVS group, a lower rate of mounting was observed than in the other three groups. Moreover, significantly fewer estrus behaviors were noticed in the OVS protocol group (P < 0.05). Both first service conception and overall conception rates were significantly higher (P < 0.05) in the CIDR and OVS treatment groups. In conclusion, the CIDR and OVS protocols appear to be the best practice for the synchronization of estrus for reproductive competence through the CCDC in Hanwoo cows. However, CIDR has a practical advantage over OVS with respect to estrus detection. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Reconstruction of 137Cs activity in the ocean following the Fukushima Daiichi Nuclear Power Plant Accident

    NASA Astrophysics Data System (ADS)

    Tsumune, Daisuke; Aoyama, Michio; Tsubono, Takaki; Tateda, Yutaka; Misumi, Kazuhiro; Hayami, Hiroshi; Toyoda, Yasuhiro; Maeda, Yoshiaki; Yoshida, Yoshikatsu; Uematsu, Mitsuo

    2014-05-01

    A series of accidents at the Fukushima Dai-ichi Nuclear Power Plant following the earthquake and tsunami of 11 March 2011 resulted in the release of radioactive materials to the ocean by two major pathways, direct release from the accident site and atmospheric deposition. We reconstructed spatiotemporal variability of 137Cs activity in the ocean by the comparison model simulations and observed data. We employed a regional scale and the North Pacific scale oceanic dispersion models, an atmospheric transport model, a sediment transport model, a dynamic biological compartment model for marine biota and river runoff model to investigate the oceanic contamination. Direct releases of 137Cs were estimated for more than 2 years after the accident by comparing simulated results and observed activities very close to the site. The estimated total amounts of directly released 137Cs was 3.6±0.7 PBq. Directly release rate of 137Cs decreased exponentially with time by the end of December 2012 and then, was almost constant. The daily release rate of 137Cs was estimated to be 3.0 x 1010 Bq day-1 by the end of September 2013. The activity of directly released 137Cs was detectable only in the coastal zone after December 2012. Simulated 137Cs activities attributable to direct release were in good agreement with observed activities, a result that implies the estimated direct release rate was reasonable, while simulated 137Cs activities attributable to atmospheric deposition were low compared to measured activities. The rate of atmospheric deposition onto the ocean was underestimated because of a lack of measurements of dose rate and air activity of 137Cs over the ocean when atmospheric deposition rates were being estimated. Observed 137Cs activities attributable to atmospheric deposition in the ocean helped to improve the accuracy of simulated atmospheric deposition rates. Although there is no observed data of 137Cs activity in the ocean from 11 to 21 March 2011, observed data of marine biota should reflect the history of 137Cs activity in this early period. The comparisons between simulated 137Cs activity of marine biota by a dynamic biological compartment and observed data also suggest that simulated 137Cs activity attributable to atmospheric deposition was underestimated in this early period. In addition, river runoff model simulations suggest that the river flux of 137Cs to the ocean was effective to the 137Cs activity in the ocean in this early period. The sediment transport model simulations suggests that the inventory of 137Cs in sediment was less than 10

  16. An aerial sightability model for estimating ferruginous hawk population size

    USGS Publications Warehouse

    Ayers, L.W.; Anderson, S.H.

    1999-01-01

    Most raptor aerial survey projects have focused on numeric description of visibility bias without identifying the contributing factors or developing predictive models to account for imperfect detection rates. Our goal was to develop a sightability model for nesting ferruginous hawks (Buteo regalis) that could account for nests missed during aerial surveys and provide more accurate population estimates. Eighteen observers, all unfamiliar with nest locations in a known population, searched for nests within 300 m of flight transects via a Maule fixed-wing aircraft. Flight variables tested for their influence on nest-detection rates included aircraft speed, height, direction of travel, time of day, light condition, distance to nest, and observer experience level. Nest variables included status (active vs. inactive), condition (i.e., excellent, good, fair, poor, bad), substrate type, topography, and tree density. A multiple logistic regression model identified nest substrate type, distance to nest, and observer experience level as significant predictors of detection rates (P < 0.05). The overall model was significant (??26 = 124.4, P < 0.001, n = 255 nest observations), and the correct classification rate was 78.4%. During 2 validation surveys, observers saw 23.7% (14/59) and 36.5% (23/63) of the actual population. Sightability model predictions, with 90% confidence intervals, captured the true population in both tests. Our results indicate standardized aerial surveys, when used in conjunction with the predictive sightability model, can provide unbiased population estimates for nesting ferruginous hawks.

  17. Nitrite oxidation in the Namibian oxygen minimum zone

    PubMed Central

    Füssel, Jessika; Lam, Phyllis; Lavik, Gaute; Jensen, Marlene M; Holtappels, Moritz; Günter, Marcel; Kuypers, Marcel MM

    2012-01-01

    Nitrite oxidation is the second step of nitrification. It is the primary source of oceanic nitrate, the predominant form of bioavailable nitrogen in the ocean. Despite its obvious importance, nitrite oxidation has rarely been investigated in marine settings. We determined nitrite oxidation rates directly in 15N-incubation experiments and compared the rates with those of nitrate reduction to nitrite, ammonia oxidation, anammox, denitrification, as well as dissimilatory nitrate/nitrite reduction to ammonium in the Namibian oxygen minimum zone (OMZ). Nitrite oxidation (⩽372 nM NO2− d−1) was detected throughout the OMZ even when in situ oxygen concentrations were low to non-detectable. Nitrite oxidation rates often exceeded ammonia oxidation rates, whereas nitrate reduction served as an alternative and significant source of nitrite. Nitrite oxidation and anammox co-occurred in these oxygen-deficient waters, suggesting that nitrite-oxidizing bacteria (NOB) likely compete with anammox bacteria for nitrite when substrate availability became low. Among all of the known NOB genera targeted via catalyzed reporter deposition fluorescence in situ hybridization, only Nitrospina and Nitrococcus were detectable in the Namibian OMZ samples investigated. These NOB were abundant throughout the OMZ and contributed up to ∼9% of total microbial community. Our combined results reveal that a considerable fraction of the recently recycled nitrogen or reduced NO3− was re-oxidized back to NO3− via nitrite oxidation, instead of being lost from the system through the anammox or denitrification pathways. PMID:22170426

  18. Performance analysis of an all-digital BPSK direct sequence spread-spectrum IF receiver architecture

    NASA Astrophysics Data System (ADS)

    Chung, Bong-Young; Chien, Charles; Samueli, Henry; Jain, Rajeev

    1993-09-01

    A VLSI architecture for an all-digital binary phase shift keyed (BPSK) direct-sequence (DS) spread spectrum (SS) IF receiver is presented, and an in-depth performance analysis is given. The all-digital architecture incorporates a Costar loop for carrier recovery and a delay-locked loop for clock recovery. For the PN acquisition block, a robust energy detection scheme is proposed to reduce false PN locks over a broad range of signal-to-noise ratios. The proposed architecture is intended for use in the 902-928 MHz unlicensed spread spectrum radio band. A 100 kbs information rate and a 12.7 Mchips/second PN code rate are assumed. The IF center frequency is 12.7 MHz and the IF sampling rate is 50.8 Msamples/ second, which is the Nyquist rate for the 25.4 MHz bandwidth signal. Finite wordlength effects have been simulated to optimize the architecture, thereby minimizing the chip area, and results of the finite wordlength simulations demonstrate that the chip architecture achieves a bit error rate performance within 1 dB of theory in an additive white Gaussian noise channel. The probability of PN acquisition within 5 ms is approximately 56% at -17 dB IF input SNR and 82% at -11 dB IF input SNR.

  19. Life-cycle changes and zinc shortage in cadmium-tolerant midges, Chironomus riparius (Diptera), reared in the absence of cadmium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Postma, J.F.; Mol, S.; Larsen, H.

    1995-01-01

    Adaptation to selected metals is known to modify life-cycle characteristics of some invertebrates and can modify the response to other metals. The reverse process, i.e., adaptation to nonpolluted conditions in a metal-tolerant strain, was studied here for a cadmium-tolerant population of the midge Chironomus riparius to detect whether this backward adaptation followed the same lines. It appeared that cadmium-tolerant populations, reared in the absence of cadmium, continued to suffer from high mortality rates and lowered larval growth rates and reproductive success. Also, some cadmium-tolerant populations accumulated more zinc than did nontolerant populations. Successive experiments in which both cadmium-tolerant and nontolerantmore » populations were exposed to zinc indicated that the reduced growth rate and reproduction were a direct consequence of zinc shortage in tolerant midges reared in the absence of cadmium. Mortality among cadmium-tolerant midges was, however, not lowered by zinc exposure and, judged by their high mortality rates, these midges were even more sensitive to zinc than were nontolerant chironomids. It was concluded that cadmium-tolerant chironomid populations recovering from prolonged exposure are affected by an increased need for zinc as well as by an increased mortality rate as a direct consequence of their earlier adaptation process.« less

  20. Fluorescence Excitation Models of Ammonia and Amidogen Radical (NH2) in Comets: Application to Comet C/2004 Q2 (Machholz)

    NASA Technical Reports Server (NTRS)

    Kawakita, Hideyo; Mumma, Michael J.

    2011-01-01

    Ammonia is a major reservoir of nitrogen atoms in cometary materials. However, detections of ammonia in comets are rare, with several achieved at radio wavelengths. A few more detections were obtained through near-infrared observations (around the 3 m wavelength region), but moderate relative velocity shifts are required to separate emission lines of cometary ammonia from telluric absorption lines in the 3 micron wavelength region. On the other hand, the amidogen radical (NH2 -- a photodissociation product of ammonia in the coma) also shows rovibrational emission lines in the 3 micron wavelength region. Thus, gas production rates for ammonia can be determined from the rovibrational emission lines of ammonia (directly) and amidogen radical (indirectly) simultaneously in the near-infrared. In this article, we present new fluorescence excitation models for cometary ammonia and amidogen radical in the near-infrared, and we apply these models to the near-infrared high-dispersion spectra of comet C/2004 Q2 (Machholz) to determine the mixing ratio of ammonia to water in the comet. Based on direct detection of NH3 lines, the mixing ratio of NH3/H2O is 0.46% +/- 0.03% in C/2004 Q2 (Machholz), in agreement with other results. The mixing ratio of ammonia determined from the NH2 observations (0.31% -- 0.79%) is consistent but has relatively larger error, owing to uncertainty in the photodissociation rates of ammonia. At the present level of accuracy, we confirm that NH3 could be the sole parent of NH2 in this comet.

  1. [Application of MALDI-TOF-MS in gene testing for non-syndromic hearing loss].

    PubMed

    Zeng, Yun; Jiang, Dan; Feng, Da-fei; Jin, Dong-dong; Wu, Xiao-hui; Ding, Yan-li; Zou, Jing

    2013-12-01

    To investigate the feasibility of Matrix-Assisted Laser Desorption-Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS) , according to the genetic test of non-syndromic hearing loss (NSHL), and check using the direct sequencing. Peripheral blood was collected from 454 NSHL patients. DNA samples were extracted and 20 loci of the four common disease-causing genes were analysed by MALDI-TOF-MS, including GJB2 (35delG, 167delT, 176_191del16, 235delC, 299_300delAT ), GJB3 (538C→T, 547G→A), SLC26A4 (281C→T, 589G→A, IVS7-2A→G, 1174A→T, 1226G→A, 1229C→T, IVS15+5G→A, 1975G→C, 2027T→A, 2162C→T, 2168A→G), and mitochondrial 12S rRNA (1494C→T, 1555A→G). Direct sequencing was also used to analyse the aforementioned 20 loci in order to validate the accuracy of MALDI-TOF-MS. Among the 454 patients, 166 cases (36.56%) of disease-causing mutations were detected, which included 69 cases (21.15%) of GJB2 gene mutation, four cases (0.88%) of GJB3 gene mutation, 64 cases (14.10%) of SLC26A4 gene mutation, and three cases (0.66%) of mitochondrial 12S rRNA gene mutation. Moreover, the results obtained from direct sequencing and MALDI-TOF-MS were consistent, and the results showed that the two methods were consistent. The MALDI-TOF-MS detection method was designed based on the hearing loss-related mutation hotspots seen in the Chinese population, and it has a high detection rate for NSHL related mutations. In comparison to the conventional detection methods, MALDI-TOF-MS has the following advantages: more detection sites, greater coverage, accurate, high throughput and low cost. Therefore, this method is capable of satisfying the needs of clinical detection for hearing impairment and it is suitable for large-scale implementation.

  2. [Characteristics of blood type irregular antibodies in Han population of Chinese Sichuan area].

    PubMed

    Li, Cui-Ying; Li, Yun-Ming; Huang, Fei; Xiao, Jie; Xu, Hong

    2015-04-01

    To analyze the distribution of irregular antibody of red blood cells in Han population of Chinese Sichuan area, so as to provide valuable information for the safety of transfusion and decrease of immune hemolytic transfusion reaction. Blood samples from June 2006 to May 2013 were tested for irregular antibody screening and identification, calculating the composition rate, group characteristics and the positive detection rate of irregular antibody. A total of 36287 blood samples were tested, out of them 571 samples were the irregular antibody positive, the positive rate was 1.574%(571/36 287), specific alloantibodies were found in 312 samples, the positive rate was 0.860%(312/36287). And autoantibody was found in 259 samples, the positive rate was 0.714%(259/36 287). The specific alloantibodies ratio in Rh system was the highest, reaching to 73.72%(230/312) with the positive rate of 0.634%;36 cases in Lewis system, account for 11.54%(36/312) with the positive rate of 0.099%; 34 cases in MNS system account for 10.89%(34/312) with the positive rate of 0.094%; direct coomb test showed positive result in 284 samples, the rate was 0.78%. The detected rate of positive irregular antibody in female is obviously higher than that in male patients (P<0.001), and it is also higher in people with pregnancy or transfusion than that in those without it (P<0.05). The irregular antibody screening and identification are very important in blood transfusion, especially for female and people with transfusion or pregnant history.

  3. Anaerobically Grown Escherichia coli Has an Enhanced Mutation Rate and Distinct Mutational Spectra

    PubMed Central

    Shewaramani, Sonal; Finn, Thomas J.; Kassen, Rees; Rainey, Paul B.

    2017-01-01

    Oxidative stress is a major cause of mutation but little is known about how growth in the absence of oxygen impacts the rate and spectrum of mutations. We employed long-term mutation accumulation experiments to directly measure the rates and spectra of spontaneous mutation events in Escherichia coli populations propagated under aerobic and anaerobic conditions. To detect mutations, whole genome sequencing was coupled with methods of analysis sufficient to identify a broad range of mutational classes, including structural variants (SVs) generated by movement of repetitive elements. The anaerobically grown populations displayed a mutation rate nearly twice that of the aerobic populations, showed distinct asymmetric mutational strand biases, and greater insertion element activity. Consistent with mutation rate and spectra observations, genes for transposition and recombination repair associated with SVs were up-regulated during anaerobic growth. Together, these results define differences in mutational spectra affecting the evolution of facultative anaerobes. PMID:28103245

  4. A novel alignment-free method for detection of lateral genetic transfer based on TF-IDF.

    PubMed

    Cong, Yingnan; Chan, Yao-Ban; Ragan, Mark A

    2016-07-25

    Lateral genetic transfer (LGT) plays an important role in the evolution of microbes. Existing computational methods for detecting genomic regions of putative lateral origin scale poorly to large data. Here, we propose a novel method based on TF-IDF (Term Frequency-Inverse Document Frequency) statistics to detect not only regions of lateral origin, but also their origin and direction of transfer, in sets of hierarchically structured nucleotide or protein sequences. This approach is based on the frequency distributions of k-mers in the sequences. If a set of contiguous k-mers appears sufficiently more frequently in another phyletic group than in its own, we infer that they have been transferred from the first group to the second. We performed rigorous tests of TF-IDF using simulated and empirical datasets. With the simulated data, we tested our method under different parameter settings for sequence length, substitution rate between and within groups and post-LGT, deletion rate, length of transferred region and k size, and found that we can detect LGT events with high precision and recall. Our method performs better than an established method, ALFY, which has high recall but low precision. Our method is efficient, with runtime increasing approximately linearly with sequence length.

  5. Observation of Signatures of Meteoroidal Water in the Lunar Exosphere by the LADEE NMS Instrument

    NASA Astrophysics Data System (ADS)

    Benna, M.; Elphic, R. C.; Hurley, D.; Stubbs, T. J.; Mahaffy, P. R.

    2017-12-01

    During its seven months in orbit, the Neutral Mass Spectrometer (NMS) of the Lunar Atmosphere and Dust Environment Explorer (LADEE) Mission measured the composition and variability of the tenuous lunar atmosphere. These measurements led to the detection of signatures of water group neutrals (H2O and/or OH) in the exosphere of the Moon. The signature of water has been measured as sporadic, short-lived signal increases above instrument background levels. The NMS data show that the occurrence rate of the high signal water "spikes" is correlated with periods of major annual meteoroid streams. Moreover, the daily water detection rate is in agreement with the expected evolution of the incoming meteoroidal impact flux at the Moon. Monte Carlo modeling of the evolution of vaporized water indicates that the signatures detected by the NMS instrument are commensurate in size and distribution of the energetic fraction of the vapors released by impacts that occurred near the location of the spacecraft. These measurements provide the first direct constraints on the contribution of meteoroid-delivered water to the sequestered ice in the permanently shadow regions of the lunar poles. They also provide a new technique for real-time observations of meteoroid impacts on airless bodies of the solar system through the detection of their associated volatile signatures.

  6. Comparisons of GLM and LMA Observations

    NASA Astrophysics Data System (ADS)

    Thomas, R. J.; Krehbiel, P. R.; Rison, W.; Stanley, M. A.; Attanasio, A.

    2017-12-01

    Observations from 3-dimensional VHF lightning mapping arrays (LMAs) provide a valuable basis for evaluating the spatial accuracy and detection efficiencies of observations from the recently launched, optical-based Geosynchronous Lightning Mapper (GLM). In this presentation, we describe results of comparing the LMA and GLM observations. First, the observations are compared spatially and temporally at the individual event (pixel) level for sets of individual discharges. For LMA networks in Florida, Colorado, and Oklahoma, the GLM observations are well correlated time-wise with LMA observations but are systematically offset by one- to two pixels ( 10 to 15 or 20 km) in a southwesterly direction from the actual lightning activity. The graphical comparisons show a similar location uncertainty depending on the altitude at which the scattered light is emitted from the parent cloud, due to being observed at slant ranges. Detection efficiencies (DEs) can be accurately determined graphically for intervals where individual flashes in a storm are resolved time-wise, and DEs and false alarm rates can be automated using flash sorting algorithms for overall and/or larger storms. This can be done as a function of flash size and duration, and generally shows high detection rates for larger flashes. Preliminary results during the May 1 2017 ER-2 overflight of Colorado storms indicate decreased detection efficiency if the storm is obscured by an overlying cloud layer.

  7. Gadolinium-loaded Plastic Scintillators for Thermal Neutron Detection using Compensation

    NASA Astrophysics Data System (ADS)

    Dumazert, Jonathan; Coulon, Romain; Hamel, Matthieu; Carrel, Frédérick; Sguerra, Fabien; Normand, Stéphane; Méchin, Laurence; Bertrand, Guillaume H. V.

    2016-06-01

    Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by Gd-155 and Gd-157, alternative treatment to pulse-shape discrimination has to be proposed in order to display a count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon and fast neutron radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a not-gadolinium loaded compensation scintillator solely interacts with the fast neutron and photon part of incident radiation. After the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate post-background response compensation falls into statistical fluctuations or provides a robust indication of neutron activity. Laboratory samples are tested under both photon and neutron irradiations, allowing the authors to investigate the performance of the overall detection system in terms of sensitivity and detection limits, especially with regards to a similar-active volume He-3 based commercial counter. The study reveals satisfactory figures of merit in terms of sensitivity and directs future investigation toward promising paths.

  8. Real Time Intelligent Target Detection and Analysis with Machine Vision

    NASA Technical Reports Server (NTRS)

    Howard, Ayanna; Padgett, Curtis; Brown, Kenneth

    2000-01-01

    We present an algorithm for detecting a specified set of targets for an Automatic Target Recognition (ATR) application. ATR involves processing images for detecting, classifying, and tracking targets embedded in a background scene. We address the problem of discriminating between targets and nontarget objects in a scene by evaluating 40x40 image blocks belonging to an image. Each image block is first projected onto a set of templates specifically designed to separate images of targets embedded in a typical background scene from those background images without targets. These filters are found using directed principal component analysis which maximally separates the two groups. The projected images are then clustered into one of n classes based on a minimum distance to a set of n cluster prototypes. These cluster prototypes have previously been identified using a modified clustering algorithm based on prior sensed data. Each projected image pattern is then fed into the associated cluster's trained neural network for classification. A detailed description of our algorithm will be given in this paper. We outline our methodology for designing the templates, describe our modified clustering algorithm, and provide details on the neural network classifiers. Evaluation of the overall algorithm demonstrates that our detection rates approach 96% with a false positive rate of less than 0.03%.

  9. Simplified Protocol for Carba NP Test for Enhanced Detection of Carbapenemase Producers Directly from Bacterial Cultures.

    PubMed

    Pasteran, Fernando; Tijet, Nathalie; Melano, Roberto G; Corso, Alejandra

    2015-12-01

    We compared carbapenemase detection among 266 Gram-negative bacilli (161 carbapenemase producers) using the Carba NP tests issued by the CLSI (CNPt-CLSI) and a novel protocol (CNPt-direct) designed for carbapenemase detection direct from bacterial cultures (instead of bacterial extracts required by the CLSI tests). The specificities were comparable (100%), but the CNPt-direct was more sensitive (98% versus 84%). The CNPt-direct was easier to perform due to the direct use of colonies and offered a more robust detection of carbapenemase producers. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  10. A New Type of Transient High-Energy Source in the Direction of the Galactic Centre

    NASA Technical Reports Server (NTRS)

    Kouveliotou, C.; VanParadijs, J.; Fishman, G. J.; Briggs, M. S.; Kommers, J.; Harmon, B. A.; Meegan, C. A.; Lewin, W. H. G.

    1996-01-01

    Sources of high-energy (greater than 20 keV) bursts fall into two distinct types: the non-repeating gamma-ray bursters, several thousand of which have been detected but whose origin remains unknown, and the soft gamma-ray repeaters (SGRs), of which there are only three. The SGRs are known to be associated with supernova remnants, suggesting that the burst events most probably originate from young neutron stars. Here we report the detection of a third type of transient high-energy source. On 2 December 1995, we observed the onset of a sequence of hard X-ray bursts from a direction close to that of the Galactic Center. The interval between bursts was initially several minutes, but after two days, the burst rate had dropped to about one per hour and has been largely unchanged since then. More than 1,000 bursts have now been detected, with remarkably similar light curves and intensities; this behaviour is unprecendented among transient X-ray and gamma-ray sources. We suggest that the origin of these bursts might be related to the spasmodic accretion of material onto a neutron star.

  11. OSSOS: X. How to use a Survey Simulator: Statistical Testing of Dynamical Models Against the Real Kuiper Belt

    NASA Astrophysics Data System (ADS)

    Lawler, Samantha M.; Kavelaars, J. J.; Alexandersen, Mike; Bannister, Michele T.; Gladman, Brett; Petit, Jean-Marc; Shankman, Cory

    2018-05-01

    All surveys include observational biases, which makes it impossible to directly compare properties of discovered trans-Neptunian Objects (TNOs) with dynamical models. However, by carefully keeping track of survey pointings on the sky, detection limits, tracking fractions, and rate cuts, the biases from a survey can be modelled in Survey Simulator software. A Survey Simulator takes an intrinsic orbital model (from, for example, the output of a dynamical Kuiper belt emplacement simulation) and applies the survey biases, so that the biased simulated objects can be directly compared with real discoveries. This methodology has been used with great success in the Outer Solar System Origins Survey (OSSOS) and its predecessor surveys. In this chapter, we give four examples of ways to use the OSSOS Survey Simulator to gain knowledge about the true structure of the Kuiper Belt. We demonstrate how to statistically compare different dynamical model outputs with real TNO discoveries, how to quantify detection biases within a TNO population, how to measure intrinsic population sizes, and how to use upper limits from non-detections. We hope this will provide a framework for dynamical modellers to statistically test the validity of their models.

  12. Financial Knudsen number: Breakdown of continuous price dynamics and asymmetric buy-and-sell structures confirmed by high-precision order-book information.

    PubMed

    Yura, Yoshihiro; Takayasu, Hideki; Sornette, Didier; Takayasu, Misako

    2015-10-01

    We generalize the description of the dynamics of the order book of financial markets in terms of a Brownian particle embedded in a fluid of incoming, exiting, and annihilating particles by presenting a model of the velocity on each side (buy and sell) independently. The improved model builds on the time-averaged number of particles in the inner layer and its change per unit time, where the inner layer is revealed by the correlations between price velocity and change in the number of particles (limit orders). This allows us to introduce the Knudsen number of the financial Brownian particle motion and its asymmetric version (on the buy and sell sides). Not being considered previously, the asymmetric Knudsen numbers are crucial in finance in order to detect asymmetric price changes. The Knudsen numbers allows us to characterize the conditions for the market dynamics to be correctly described by a continuous stochastic process. Not questioned until now for large liquid markets such as the USD-JPY and EUR-USD exchange rates, we show that there are regimes when the Knudsen numbers are so high that discrete particle effects dominate, such as during market stresses and crashes. We document the presence of imbalances of particles depletion rates on the buy and sell sides that are associated with high Knudsen numbers and violent directional price changes. This indicator can detect the direction of the price motion at the early stage while the usual volatility risk measure is blind to the price direction.

  13. [Laboratory diagnosis of auto-immune hemolytic anemia: characteristics of the manual direct test of Polybrene].

    PubMed

    Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A

    1998-01-01

    The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.

  14. Gamma-ray mirror technology for NDA of spent fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Descalle, M. A.; Ruz-Armendariz, J.; Decker, T.

    Direct measurements of gamma rays emitted by fissile material have been proposed as an alternative to measurements of the gamma rays from fission products. From a safeguards applications perspective, direct detection of uranium (U) and plutonium (Pu) K-shell fluorescence emission lines and specific lines from some of their isotopes could lead to improved shipper-receiver difference or input accountability at the start of Pu reprocessing. However, these measurements are difficult to implement when the spent fuel is in the line-of-sight of the detector, as the detector is exposed to high rates dominated by fission product emissions. To overcome the combination ofmore » high rates and high background, grazing incidence multilayer mirrors have been proposed as a solution to selectively reflect U and Pu hard X-ray and soft gamma rays in the 90 to 420 keV energy into a high-purity germanium (HPGe) detector shielded from the direct line-of-sight of spent fuel. Several groups demonstrated that K-shell fluorescence lines of U and Pu in spent fuel could be detected with Ge detectors. In the field of hard X-ray optics the performance of reflective multilayer coated reflective optics was demonstrated up to 645 keV at the European Synchrotron Radiation Facility. Initial measurements conducted at Oak Ridge National Laboratory with sealed sources and scoping experiments conducted at the ORNL Irradiated Fuels Examination Laboratory (IFEL) with spent nuclear fuel further demonstrated the pass-band properties of multilayer mirrors for reflecting specific emission lines into 1D and 2D HPGe detectors, respectively.« less

  15. Financial Knudsen number: Breakdown of continuous price dynamics and asymmetric buy-and-sell structures confirmed by high-precision order-book information

    NASA Astrophysics Data System (ADS)

    Yura, Yoshihiro; Takayasu, Hideki; Sornette, Didier; Takayasu, Misako

    2015-10-01

    We generalize the description of the dynamics of the order book of financial markets in terms of a Brownian particle embedded in a fluid of incoming, exiting, and annihilating particles by presenting a model of the velocity on each side (buy and sell) independently. The improved model builds on the time-averaged number of particles in the inner layer and its change per unit time, where the inner layer is revealed by the correlations between price velocity and change in the number of particles (limit orders). This allows us to introduce the Knudsen number of the financial Brownian particle motion and its asymmetric version (on the buy and sell sides). Not being considered previously, the asymmetric Knudsen numbers are crucial in finance in order to detect asymmetric price changes. The Knudsen numbers allows us to characterize the conditions for the market dynamics to be correctly described by a continuous stochastic process. Not questioned until now for large liquid markets such as the USD-JPY and EUR-USD exchange rates, we show that there are regimes when the Knudsen numbers are so high that discrete particle effects dominate, such as during market stresses and crashes. We document the presence of imbalances of particles depletion rates on the buy and sell sides that are associated with high Knudsen numbers and violent directional price changes. This indicator can detect the direction of the price motion at the early stage while the usual volatility risk measure is blind to the price direction.

  16. Networked gamma radiation detection system for tactical deployment

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald; Smith, Ethan; Guss, Paul; Mitchell, Stephen

    2015-08-01

    A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2″ × 4″ × 16″ sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

  17. Detection and decay rates of prey and prey symbionts in the gut of a predator through metagenomics.

    PubMed

    Paula, Débora P; Linard, Benjamin; Andow, David A; Sujii, Edison R; Pires, Carmen S S; Vogler, Alfried P

    2015-07-01

    DNA methods are useful to identify ingested prey items from the gut of predators, but reliable detection is hampered by low amounts of degraded DNA. PCR-based methods can retrieve minute amounts of starting material but suffer from amplification biases and cross-reactions with the predator and related species genomes. Here, we use PCR-free direct shotgun sequencing of total DNA isolated from the gut of the harlequin ladybird Harmonia axyridis at five time points after feeding on a single pea aphid Acyrthosiphon pisum. Sequence reads were matched to three reference databases: Insecta mitogenomes of 587 species, including H. axyridis sequenced here; A. pisum nuclear genome scaffolds; and scaffolds and complete genomes of 13 potential bacterial symbionts. Immediately after feeding, multicopy mtDNA of A. pisum was detected in tens of reads, while hundreds of matches to nuclear scaffolds were detected. Aphid nuclear DNA and mtDNA decayed at similar rates (0.281 and 0.11 h(-1) respectively), and the detectability periods were 32.7 and 23.1 h. Metagenomic sequencing also revealed thousands of reads of the obligate Buchnera aphidicola and facultative Regiella insecticola aphid symbionts, which showed exponential decay rates significantly faster than aphid DNA (0.694 and 0.80 h(-1) , respectively). However, the facultative aphid symbionts Hamiltonella defensa, Arsenophonus spp. and Serratia symbiotica showed an unexpected temporary increase in population size by 1-2 orders of magnitude in the predator guts before declining. Metagenomics is a powerful tool that can reveal complex relationships and the dynamics of interactions among predators, prey and their symbionts. © 2014 John Wiley & Sons Ltd.

  18. Early Science with the Large Millimeter Telescope: Detection of Dust Emission in Multiple Images of a Normal Galaxy at z > 4 Lensed by a Frontier Fields Cluster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, Alexandra; Battisti, Andrew; Wilson, Grant W.

    We directly detect dust emission in an optically detected, multiply imaged galaxy lensed by the Frontier Fields cluster MACSJ0717.5+3745. We detect two images of the same galaxy at 1.1 mm with the AzTEC camera on the Large Millimeter Telescope leaving no ambiguity in the counterpart identification. This galaxy, MACS0717-Az9, is at z > 4 and the strong lensing model ( μ = 7.5) allows us to calculate an intrinsic IR luminosity of 9.7 × 10{sup 10} L {sub ⊙} and an obscured star formation rate of 14.6 ± 4.5 M {sub ⊙} yr{sup −1}. The unobscured star formation rate frommore » the UV is only 4.1 ± 0.3 M {sub ⊙} yr{sup −1}, which means the total star formation rate (18.7 ± 4.5 M {sub ⊙} yr{sup −1}) is dominated (75%–80%) by the obscured component. With an intrinsic stellar mass of only 6.9 × 10{sup 9} M {sub ⊙}, MACS0717-Az9 is one of only a handful of z > 4 galaxies at these lower masses that is detected in dust emission. This galaxy lies close to the estimated star formation sequence at this epoch. However, it does not lie on the dust obscuration relation (IRX- β ) for local starburst galaxies and is instead consistent with the Small Magellanic Cloud attenuation law. This remarkable lower mass galaxy, showing signs of both low metallicity and high dust content, may challenge our picture of dust production in the early universe.« less

  19. Quaternary pulse position modulation electronics for free-space laser communications

    NASA Technical Reports Server (NTRS)

    Budinger, J. M.; Kerslake, S. D.; Nagy, L. A.; Shalkhauser, M. J.; Soni, N. J.; Cauley, M. A.; Mohamed, J. H.; Stover, J. B.; Romanofsky, R. R.; Lizanich, P. J.

    1991-01-01

    The development of a high data-rate communications electronic subsystem for future application in free-space, direct-detection laser communications is described. The dual channel subsystem uses quaternary pulse position modulation (GPPM) and operates at a throughput of 650 megabits per second. Transmitting functions described include source data multiplexing, channel data multiplexing, and QPPM symbol encoding. Implementation of a prototype version in discrete gallium arsenide logic, radiofrequency components, and microstrip circuitry is presented.

  20. Quaternary pulse position modulation electronics for free-space laser communications

    NASA Technical Reports Server (NTRS)

    Budinger, J. M.; Kerslake, S. D.; Nagy, L. A.; Shalkhauser, M. J.; Soni, N. J.; Cauley, M. A.; Mohamed, J. H.; Stover, J. B.; Romanofsky, R. R.; Lizanich, P. J.

    1991-01-01

    The development of a high data-rate communications electronic subsystem for future application in free-space, direct-detection laser communications is described. The dual channel subsystem uses quaternary pulse position modulation (QPPM) and operates at a throughput of 650 megabits per second. Transmitting functions described include source data multiplexing, channel data multiplexing, and QPPM symbol encoding. Implementation of a prototype version in discrete gallium arsenide logic, radiofrequency components, and microstrip circuitry is presented.

  1. Method of Menu Selection by Gaze Movement Using AC EOG Signals

    NASA Astrophysics Data System (ADS)

    Kanoh, Shin'ichiro; Futami, Ryoko; Yoshinobu, Tatsuo; Hoshimiya, Nozomu

    A method to detect the direction and the distance of voluntary eye gaze movement from EOG (electrooculogram) signals was proposed and tested. In this method, AC-amplified vertical and horizontal transient EOG signals were classified into 8-class directions and 2-class distances of voluntary eye gaze movements. A horizontal and a vertical EOGs during eye gaze movement at each sampling time were treated as a two-dimensional vector, and the center of gravity of the sample vectors whose norms were more than 80% of the maximum norm was used as a feature vector to be classified. By the classification using the k-nearest neighbor algorithm, it was shown that the averaged correct detection rates on each subject were 98.9%, 98.7%, 94.4%, respectively. This method can avoid strict EOG-based eye tracking which requires DC amplification of very small signal. It would be useful to develop robust human interfacing systems based on menu selection for severely paralyzed patients.

  2. Evaluating structural pattern recognition for handwritten math via primitive label graphs

    NASA Astrophysics Data System (ADS)

    Zanibbi, Richard; Mouchère, Harold; Viard-Gaudin, Christian

    2013-01-01

    Currently, structural pattern recognizer evaluations compare graphs of detected structure to target structures (i.e. ground truth) using recognition rates, recall and precision for object segmentation, classification and relationships. In document recognition, these target objects (e.g. symbols) are frequently comprised of multiple primitives (e.g. connected components, or strokes for online handwritten data), but current metrics do not characterize errors at the primitive level, from which object-level structure is obtained. Primitive label graphs are directed graphs defined over primitives and primitive pairs. We define new metrics obtained by Hamming distances over label graphs, which allow classification, segmentation and parsing errors to be characterized separately, or using a single measure. Recall and precision for detected objects may also be computed directly from label graphs. We illustrate the new metrics by comparing a new primitive-level evaluation to the symbol-level evaluation performed for the CROHME 2012 handwritten math recognition competition. A Python-based set of utilities for evaluating, visualizing and translating label graphs is publicly available.

  3. Augury of darkness: the low-mass dark Z' portal

    DOE PAGES

    Alves, Alexandre; Arcadi, Giorgio; Mambrini, Yann; ...

    2017-04-28

    Dirac fermion dark matter models with heavy Z' mediators are subject to stringent constraints from spin-independent direct searches and from LHC bounds, cornering them to live near the Z' resonance. Such constraints can be relaxed, however, by turning off the vector coupling to Standard Model fermions, thus weakening direct detection bounds, or by resorting to light Z' masses, below the Z pole, to escape heavy resonance searches at the LHC. In this work we investigate both cases, as well as the applicability of our findings to Majorana dark matter. We derive collider bounds for light Z' gauge bosons using themore » CL S method, spin-dependent scattering limits, as well as the spin-independent scattering rate arising from the evolution of couplings between the energy scale of the mediator mass and the nuclear energy scale, and indirect detection limits. In conclusion, we show that such scenarios are still rather constrained by data, and that near resonance they could accommodate the gamma-ray GeV excess in the Galactic center.« less

  4. Photometric and fluorometric continuous kinetic assay of acid phosphatases with new substrates possessing longwave absorption and emission maxima.

    PubMed

    Koller, E; Wolfbeis, O S

    1984-11-15

    A direct and continuous kinetic method for the photometric and fluorometric determination of various acid phosphatases is described. It is based on new coumarin-derived phosphates, which after enzymatic hydrolysis undergo dissociation to form intensely colored and strongly fluorescent phenolate anions. The latter have absorption maxima ranging from 385 to 505 nm, and fluorescence maxima between 470 and 595 nm. The new substrates were compared with respect to their rate of enzymatic hydrolysis, optimum pH, and detection limits of acid phosphatase from potato and wheat germ. Detection limits of 0.001 unit/ml were found by photometry, and as low as 0.00006 unit/ml by fluorometry. The principal advantages of the new substrates over existing ones are longwave absorptions and emissions, large Stokes shifts, and the low pKa values of the corresponding phenols, thus allowing a direct and continuous assay of acid phosphatase even in weakly acidic solutions.

  5. Non-invasive determination of glucose directly in raw fruits using a continuous flow system based on microdialysis sampling and amperometric detection at an integrated enzymatic biosensor.

    PubMed

    Vargas, E; Ruiz, M A; Campuzano, S; Reviejo, A J; Pingarrón, J M

    2016-03-31

    A non-destructive, rapid and simple to use sensing method for direct determination of glucose in non-processed fruits is described. The strategy involved on-line microdialysis sampling coupled with a continuous flow system with amperometric detection at an enzymatic biosensor. Apart from direct determination of glucose in fruit juices and blended fruits, this work describes for the first time the successful application of an enzymatic biosensor-based electrochemical approach to the non-invasive determination of glucose in raw fruits. The methodology correlates, through previous calibration set-up, the amperometric signal generated from glucose in non-processed fruits with its content in % (w/w). The comparison of the obtained results using the proposed approach in different fruits with those provided by other method involving the same commercial biosensor as amperometric detector in stirred solutions pointed out that there were no significant differences. Moreover, in comparison with other available methodologies, this microdialysis-coupled continuous flow system amperometric biosensor-based procedure features straightforward sample preparation, low cost, reduced assay time (sampling rate of 7 h(-1)) and ease of automation. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Binding Isotherms and Time Courses Readily from Magnetic Resonance.

    PubMed

    Xu, Jia; Van Doren, Steven R

    2016-08-16

    Evidence is presented that binding isotherms, simple or biphasic, can be extracted directly from noninterpreted, complex 2D NMR spectra using principal component analysis (PCA) to reveal the largest trend(s) across the series. This approach renders peak picking unnecessary for tracking population changes. In 1:1 binding, the first principal component captures the binding isotherm from NMR-detected titrations in fast, slow, and even intermediate and mixed exchange regimes, as illustrated for phospholigand associations with proteins. Although the sigmoidal shifts and line broadening of intermediate exchange distorts binding isotherms constructed conventionally, applying PCA directly to these spectra along with Pareto scaling overcomes the distortion. Applying PCA to time-domain NMR data also yields binding isotherms from titrations in fast or slow exchange. The algorithm readily extracts from magnetic resonance imaging movie time courses such as breathing and heart rate in chest imaging. Similarly, two-step binding processes detected by NMR are easily captured by principal components 1 and 2. PCA obviates the customary focus on specific peaks or regions of images. Applying it directly to a series of complex data will easily delineate binding isotherms, equilibrium shifts, and time courses of reactions or fluctuations.

  7. Automatic detection and recognition of signs from natural scenes.

    PubMed

    Chen, Xilin; Yang, Jie; Zhang, Jing; Waibel, Alex

    2004-01-01

    In this paper, we present an approach to automatic detection and recognition of signs from natural scenes, and its application to a sign translation task. The proposed approach embeds multiresolution and multiscale edge detection, adaptive searching, color analysis, and affine rectification in a hierarchical framework for sign detection, with different emphases at each phase to handle the text in different sizes, orientations, color distributions and backgrounds. We use affine rectification to recover deformation of the text regions caused by an inappropriate camera view angle. The procedure can significantly improve text detection rate and optical character recognition (OCR) accuracy. Instead of using binary information for OCR, we extract features from an intensity image directly. We propose a local intensity normalization method to effectively handle lighting variations, followed by a Gabor transform to obtain local features, and finally a linear discriminant analysis (LDA) method for feature selection. We have applied the approach in developing a Chinese sign translation system, which can automatically detect and recognize Chinese signs as input from a camera, and translate the recognized text into English.

  8. Evaluation of immunomagnetic separation for the detection of Salmonella in surface waters by polymerase chain reaction.

    PubMed

    Hsu, Chao-Yu; Hsu, Bing-Mu; Chang, Tien-Yu; Hsu, Tsui-Kang; Shen, Shu-Min; Chiu, Yi-Chou; Wang, Hung-Jen; Ji, Wen-Tsai; Fan, Cheng-Wei; Chen, Jyh-Larng

    2014-09-19

    Salmonella spp. is associated with fecal pollution and capable of surviving for long periods in aquatic environments. Instead of the traditional, time-consuming biochemical detection, polymerase chain reaction (PCR) allows rapid identification of Salmonella directly concentrated from water samples. However, prevalence of Salmonella may be underestimated because of the vulnerability of PCR to various environmental chemicals like humic acid, compounded by the fact that various DNA polymerases have different susceptibility to humic acid. Because immunomagnetic separation (IMS) theoretically could isolate Salmonella from other microbes and facilitate removal of aquatic PCR inhibitors of different sizes, this study aims to compare the efficiency of conventional PCR combined with immunomagnetic separation (IMS) for Salmonella detection within a moderately polluted watershed. In our study, the positive rate was increased from 17.6% to 47% with nearly ten-fold improvement in the detection limit. These results suggest the sensitivity of Salmonella detection could be enhanced by IMS, particularly in low quality surface waters. Due to its effects on clearance of aquatic pollutants, IMS may be suitable for most DNA polymerases for Salmonella detection.

  9. Ammonia oxidation rates and nitrification in the Arabian Sea

    NASA Astrophysics Data System (ADS)

    Newell, Silvia E.; Babbin, Andrew R.; Jayakumar, Amal; Ward, Bess B.

    2011-12-01

    Nitrification rates, as well as the relationships between rates and ammonia oxidizer abundance (both archaeal and bacterial), were investigated in the Arabian Sea. Ammonia oxidation rates were measured directly using 15N-NH4+stable isotope additions in gas-impermeable, trace metal clean trilaminate bags (500 mL) at in situ temperature. Tracer incubations were performed at three stations at depths above, below, and within the oxycline of the open-ocean oxygen minimum zone (OMZ). Ammonia oxidation rates were similar to previous open-ocean measurements, ranging from undetectable to 21.6 ± 0.1 nmol L-1 d-1. The highest rates at each station occurred at the primary nitrite maximum (above the OMZ), and rates were very low at depths greater than 900 m. The abundances of both ammonia-oxidizing archaea (AOA) and ammonia-oxidizing bacteria (AOB) were estimated using theamoA gene by quantitative polymerase chain reaction (qPCR). Both AOA and AOB amoA were detected above, within, and below the OMZ, although the AOA were always more abundant than the AOB, by a factor of 35-216. Nitrification rates were not directly correlated to AOA or AOB amoA abundance. These rates offer new insight into the role of nitrification in the mesopelagic zone. The abundance of AOA amoA genes at 1000 m suggests that ˜50% of the microbial biomass could be autotrophic. Additionally, the integrated nitrification rate at depth implies that nitrification could consume most of the ammonium produced by the flux of organic carbon in the mesopelagic zone.

  10. Disease management: remote monitoring in heart failure patients with implantable defibrillators, resynchronization devices, and haemodynamic monitors.

    PubMed

    Abraham, William T

    2013-06-01

    Heart failure represents a major public health concern, associated with high rates of morbidity and mortality. A particular focus of contemporary heart failure management is reduction of hospital admission and readmission rates. While optimal medical therapy favourably impacts the natural history of the disease, devices such as cardiac resynchronization therapy devices and implantable cardioverter defibrillators have added incremental value in improving heart failure outcomes. These devices also enable remote patient monitoring via device-based diagnostics. Device-based measurement of physiological parameters, such as intrathoracic impedance and heart rate variability, provide a means to assess risk of worsening heart failure and the possibility of future hospitalization. Beyond this capability, implantable haemodynamic monitors have the potential to direct day-to-day management of heart failure patients to significantly reduce hospitalization rates. The use of a pulmonary artery pressure measurement system has been shown to significantly reduce the risk of heart failure hospitalization in a large randomized controlled study, the CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients (CHAMPION) trial. Observations from a pilot study also support the potential use of a left atrial pressure monitoring system and physician-directed patient self-management paradigm; these observations are under further investigation in the ongoing LAPTOP-HF trial. All these devices depend upon high-intensity remote monitoring for successful detection of parameter deviations and for directing and following therapy.

  11. Field Test Evaluation of Conservation Retrofits of Low-Income, Single-Family Buildings in Wisconsin: Blower-Door-Directed Infiltration Reduction Procedure, Field Test Implementation and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gettings, M.B.

    A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of themore » recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air quality, and addition of the basic cost of determining the initial leakage rate to the recommended expenditure level. Recommendations for the field test of the procedure include increasing the number of houses in the sample, more timely examination of metered data to detect anomalies, and the monitoring of indoor air temperature. Though not appropriate in a field test of a procedure, further investigation into the effects of air leakage rate reductions on heating loads needs to be performed.« less

  12. Specific capture and detection of Staphylococcus aureus with high-affinity modified aptamers to cell surface components

    PubMed Central

    Baumstummler, A; Lehmann, D; Janjic, N; Ochsner, UA

    2014-01-01

    Slow off-rate modified aptamer (SOMAmer) reagents were generated to several Staphylococcus aureus cell surface-associated proteins via SELEX with multiple modified DNA libraries using purified recombinant or native proteins. High-affinity binding agents with sub-nanomolar Kd's were obtained for staphylococcal protein A (SpA), clumping factors (ClfA, ClfB), fibronectin-binding proteins (FnbA, FnbB) and iron-regulated surface determinants (Isd). Further screening revealed several SOMAmers that specifically bound to Staph. aureus cells from all strains that were tested, but not to other staphylococci or other bacteria. SpA and ClfA SOMAmers proved useful for the selective capture and enrichment of Staph. aureus cells, as shown by culture and PCR, leading to improved limits of detection and efficient removal of PCR inhibitors. Detection of Staph. aureus cells was enhanced by several orders of magnitude when the bacterial cell surface was coated with SOMAmers followed by qPCR of the SOMAmers. Furthermore, fluorescence-labelled SpA SOMAmers demonstrated their utility as direct detection agents in flow cytometry. Significance and Impact of the Study Monitoring for microbial contamination of food, water, nonsterile products or the environment is typically based on culture, PCR or antibodies. Aptamers that bind with high specificity and affinity to well-conserved cell surface epitopes represent a promising novel type of reagents to detect bacterial cells without the need for culture or cell lysis, including for the capture and enrichment of bacteria present at low cell densities and for the direct detection via qPCR or fluorescent staining. PMID:24935714

  13. Monitoring survival rates of landbirds at varying spatial scales: An application of the MAPS Program

    USGS Publications Warehouse

    Rosenberg, D.K.; DeSante, D.F.; Hines, J.E.; Bonney, Rick; Pashley, David N.; Cooper, Robert; Niles, Larry

    2000-01-01

    Survivorship is a primary demographic parameter affecting population dynamics, and thus trends in species abundance. The Monitoring Avian Productivity and Survivorship (MAPS) program is a cooperative effort designed to monitor landbird demographic parameters. A principle goal of MAPS is to estimate annual survivorship and identify spatial patterns and temporal trends in these rates. We evaluated hypotheses of spatial patterns in survival rates among a collection of neighboring sampling sites, such as within national forests, among biogeographic provinces, and between breeding populations that winter in either Central or South America, and compared these geographic-specific models to a model of a common survival rate among all sampling sites. We used data collected during 1992-1995 from Swainson's Thrush (Cathorus ustulatus) populations in the western region of the United States. We evaluated the ability to detect spatial and temporal patterns of survivorship with simulated data. We found weak evidence of spatial differences in survival rates at the local scale of 'location,' which typically contained 3 mist-netting stations. There was little evidence of differences in survival rates among biogeographic provinces or between populations that winter in either Central or South America. When data were pooled for a regional estimate of survivorship, the percent relative bias due to pooling 'locations' was 12 years of monitoring. Detection of spatial patterns and temporal trends in survival rates from local to regional scales will provide important information for management and future research directed toward conservation of landbirds.

  14. The problem is not just sample size: the consequences of low base rates in policing experiments in smaller cities.

    PubMed

    Hinkle, Joshua C; Weisburd, David; Famega, Christine; Ready, Justin

    2013-01-01

    Hot spots policing is one of the most influential police innovations, with a strong body of experimental research showing it to be effective in reducing crime and disorder. However, most studies have been conducted in major cities, and we thus know little about whether it is effective in smaller cities, which account for a majority of police agencies. The lack of experimental studies in smaller cities is likely in part due to challenges designing statistically powerful tests in such contexts. The current article explores the challenges of statistical power and "noise" resulting from low base rates of crime in smaller cities and provides suggestions for future evaluations to overcome these limitations. Data from a randomized experimental evaluation of broken windows policing in hot spots are used to illustrate the challenges that low base rates present for evaluating hot spots policing programs in smaller cities. Analyses show low base rates make it difficult to detect treatment effects. Very large effect sizes would be required to reach sufficient power, and random fluctuations around low base rates make detecting treatment effects difficult, irrespective of power, by masking differences between treatment and control groups. Low base rates present strong challenges to researchers attempting to evaluate hot spots policing in smaller cities. As such, base rates must be taken directly into account when designing experimental evaluations. The article offers suggestions for researchers attempting to expand the examination of hot spots policing and other microplace-based interventions to smaller jurisdictions.

  15. Does Minimally Invasive Spine Surgery Minimize Surgical Site Infections?

    PubMed

    Kulkarni, Arvind Gopalrao; Patel, Ravish Shammi; Dutta, Shumayou

    2016-12-01

    Retrospective review of prospectively collected data. To evaluate the incidence of surgical site infections (SSIs) in minimally invasive spine surgery (MISS) in a cohort of patients and compare with available historical data on SSI in open spinal surgery cohorts, and to evaluate additional direct costs incurred due to SSI. SSI can lead to prolonged antibiotic therapy, extended hospitalization, repeated operations, and implant removal. Small incisions and minimal dissection intrinsic to MISS may minimize the risk of postoperative infections. However, there is a dearth of literature on infections after MISS and their additional direct financial implications. All patients from January 2007 to January 2015 undergoing posterior spinal surgery with tubular retractor system and microscope in our institution were included. The procedures performed included tubular discectomies, tubular decompressions for spinal stenosis and minimal invasive transforaminal lumbar interbody fusion (TLIF). The incidence of postoperative SSI was calculated and compared to the range of cited SSI rates from published studies. Direct costs were calculated from medical billing for index cases and for patients with SSI. A total of 1,043 patients underwent 763 noninstrumented surgeries (discectomies, decompressions) and 280 instrumented (TLIF) procedures. The mean age was 52.2 years with male:female ratio of 1.08:1. Three infections were encountered with fusion surgeries (mean detection time, 7 days). All three required wound wash and debridement with one patient requiring unilateral implant removal. Additional direct cost due to infection was $2,678 per 100 MISS-TLIF. SSI increased hospital expenditure per patient 1.5-fold after instrumented MISS. Overall infection rate after MISS was 0.29%, with SSI rate of 0% in non-instrumented MISS and 1.07% with instrumented MISS. MISS can markedly reduce the SSI rate and can be an effective tool to minimize hospital costs.

  16. A Comparison of Grizzly Bear Demographic Parameters Estimated from Non-Spatial and Spatial Open Population Capture-Recapture Models.

    PubMed

    Whittington, Jesse; Sawaya, Michael A

    2015-01-01

    Capture-recapture studies are frequently used to monitor the status and trends of wildlife populations. Detection histories from individual animals are used to estimate probability of detection and abundance or density. The accuracy of abundance and density estimates depends on the ability to model factors affecting detection probability. Non-spatial capture-recapture models have recently evolved into spatial capture-recapture models that directly include the effect of distances between an animal's home range centre and trap locations on detection probability. Most studies comparing non-spatial and spatial capture-recapture biases focussed on single year models and no studies have compared the accuracy of demographic parameter estimates from open population models. We applied open population non-spatial and spatial capture-recapture models to three years of grizzly bear DNA-based data from Banff National Park and simulated data sets. The two models produced similar estimates of grizzly bear apparent survival, per capita recruitment, and population growth rates but the spatial capture-recapture models had better fit. Simulations showed that spatial capture-recapture models produced more accurate parameter estimates with better credible interval coverage than non-spatial capture-recapture models. Non-spatial capture-recapture models produced negatively biased estimates of apparent survival and positively biased estimates of per capita recruitment. The spatial capture-recapture grizzly bear population growth rates and 95% highest posterior density averaged across the three years were 0.925 (0.786-1.071) for females, 0.844 (0.703-0.975) for males, and 0.882 (0.779-0.981) for females and males combined. The non-spatial capture-recapture population growth rates were 0.894 (0.758-1.024) for females, 0.825 (0.700-0.948) for males, and 0.863 (0.771-0.957) for both sexes. The combination of low densities, low reproductive rates, and predominantly negative population growth rates suggest that Banff National Park's population of grizzly bears requires continued conservation-oriented management actions.

  17. Search for high-energy neutrinos from gravitational wave event GW151226 and candidate LVT151012 with ANTARES and IceCube

    NASA Astrophysics Data System (ADS)

    Albert, A.; André, M.; Anghinolfi, M.; Anton, G.; Ardid, M.; Aubert, J.-J.; Avgitas, T.; Baret, B.; Barrios-Martí, J.; Basa, S.; Bertin, V.; Biagi, S.; Bormuth, R.; Bourret, S.; Bouwhuis, M. C.; Bruijn, R.; Brunner, J.; Busto, J.; Capone, A.; Caramete, L.; Carr, J.; Celli, S.; Chiarusi, T.; Circella, M.; Coelho, J. A. B.; Coleiro, A.; Coniglione, R.; Costantini, H.; Coyle, P.; Creusot, A.; Deschamps, A.; de Bonis, G.; Distefano, C.; di Palma, I.; Donzaud, C.; Dornic, D.; Drouhin, D.; Eberl, T.; El Bojaddaini, I.; Elsässer, D.; Enzenhöfer, A.; Felis, I.; Fusco, L. A.; Galatà, S.; Gay, P.; Giordano, V.; Glotin, H.; Grégoire, T.; Gracia Ruiz, R.; Graf, K.; Hallmann, S.; van Haren, H.; Heijboer, A. J.; Hello, Y.; Hernández-Rey, J. J.; Hößl, J.; Hofestädt, J.; Hugon, C.; Illuminati, G.; James, C. W.; de Jong, M.; Jongen, M.; Kadler, M.; Kalekin, O.; Katz, U.; Kießling, D.; Kouchner, A.; Kreter, M.; Kreykenbohm, I.; Kulikovskiy, V.; Lachaud, C.; Lahmann, R.; Lefèvre, D.; Leonora, E.; Lotze, M.; Loucatos, S.; Marcelin, M.; Margiotta, A.; Marinelli, A.; Martínez-Mora, J. A.; Mathieu, A.; Mele, R.; Melis, K.; Michael, T.; Migliozzi, P.; Moussa, A.; Nezri, E.; Pǎvǎlaş, G. E.; Pellegrino, C.; Perrina, C.; Piattelli, P.; Popa, V.; Pradier, T.; Quinn, L.; Racca, C.; Riccobene, G.; Sánchez-Losa, A.; Saldaña, M.; Salvadori, I.; Samtleben, D. F. E.; Sanguineti, M.; Sapienza, P.; Schüssler, F.; Sieger, C.; Spurio, M.; Stolarczyk, Th.; Taiuti, M.; Tayalati, Y.; Trovato, A.; Turpin, D.; Tönnis, C.; Vallage, B.; Vallée, C.; van Elewyck, V.; Versari, F.; Vivolo, D.; Vizzoca, A.; Wilms, J.; Zornoza, J. D.; Zúñiga, J.; Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Al Samarai, I.; Altmann, D.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Archinger, M.; Argüelles, C.; Auffenberg, J.; Axani, S.; Bagherpour, H.; Bai, X.; Barwick, S. W.; Baum, V.; Bay, R.; Beatty, J. J.; Becker Tjus, J.; Becker, K.-H.; Benzvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Bos, F.; Bose, D.; Böser, S.; Botner, O.; Bradascio, F.; Braun, J.; Brayeur, L.; Bretz, H.-P.; Bron, S.; Burgman, A.; Carver, T.; Casier, M.; Cheung, E.; Chirkin, D.; Christov, A.; Clark, K.; Classen, L.; Coenders, S.; Collin, G. H.; Conrad, J. M.; Cowen, D. F.; Cross, R.; Day, M.; de André, J. P. A. M.; de Clercq, C.; Del Pino Rosendo, E.; Dembinski, H.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; Deyoung, T.; Díaz-Vélez, J. C.; di Lorenzo, V.; Dujmovic, H.; Dumm, J. P.; Dunkman, M.; Eberhardt, B.; Ehrhardt, T.; Eichmann, B.; Eller, P.; Euler, S.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Feintzeig, J.; Felde, J.; Filimonov, K.; Finley, C.; Flis, S.; Fösig, C.-C.; Franckowiak, A.; Friedman, E.; Fuchs, T.; Gaisser, T. K.; Gallagher, J.; Gerhardt, L.; Ghorbani, K.; Giang, W.; Gladstone, L.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Haack, C.; Hallgren, A.; Halzen, F.; Hansen, E.; Hansmann, T.; Hanson, K.; Hebecker, D.; Heereman, D.; Helbing, K.; Hellauer, R.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hoshina, K.; Huang, F.; Huber, M.; Hultqvist, K.; in, S.; Ishihara, A.; Jacobi, E.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Kang, W.; Kappes, A.; Karg, T.; Karle, A.; Katz, U.; Kauer, M.; Keivani, A.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kim, M.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Kohnen, G.; Koirala, R.; Kolanoski, H.; Konietz, R.; Köpke, L.; Kopper, C.; Kopper, S.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Kroll, M.; Krückl, G.; Krüger, C.; Kunnen, J.; Kunwar, S.; Kurahashi, N.; Kuwabara, T.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lennarz, D.; Lesiak-Bzdak, M.; Leuermann, M.; Lu, L.; Lünemann, J.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Mancina, S.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Meier, M.; Menne, T.; Merino, G.; Meures, T.; Miarecki, S.; Micallef, J.; Momenté, G.; Montaruli, T.; Moulai, M.; Nahnhauer, R.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Obertacke Pollmann, A.; Olivas, A.; O'Murchadha, A.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Peiffer, P.; Penek, Ö.; Pepper, J. A.; Pérez de Los Heros, C.; Pieloth, D.; Pinat, E.; Price, P. B.; Przybylski, G. T.; Quinnan, M.; Raab, C.; Rädel, L.; Rameez, M.; Rawlins, K.; Reimann, R.; Relethford, B.; Relich, M.; Resconi, E.; Rhode, W.; Richman, M.; Riedel, B.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Sabbatini, L.; Sanchez Herrera, S. E.; Sandrock, A.; Sandroos, J.; Sarkar, S.; Satalecka, K.; Schlunder, P.; Schmidt, T.; Schoenen, S.; Schöneberg, S.; Schumacher, L.; Seckel, D.; Seunarine, S.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stanev, T.; Stasik, A.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Ström, R.; Strotjohann, N. L.; Sullivan, G. W.; Sutherland, M.; Taavola, H.; Taboada, I.; Tatar, J.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tešić, G.; Tilav, S.; Toale, P. A.; Tobin, M. N.; Toscano, S.; Tosi, D.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Unger, E.; Usner, M.; Vandenbroucke, J.; van Eijndhoven, N.; Vanheule, S.; van Rossem, M.; van Santen, J.; Vehring, M.; Voge, M.; Vogel, E.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandkowsky, N.; Waza, A.; Weaver, Ch.; Weiss, M. J.; Wendt, C.; Westerhoff, S.; Whelan, B. J.; Wickmann, S.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, T. R.; Woolsey, E.; Woschnagg, K.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Zoll, M.; Abbott, B. P.; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Ajith, P.; Allen, B.; Allocca, A.; Altin, P. A.; Ananyeva, A.; Anderson, S. B.; Anderson, W. G.; Appert, S.; Arai, K.; Araya, M. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Avila-Alvarez, A.; Babak, S.; Bacon, P.; Bader, M. K. M.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Baune, C.; Bavigadda, V.; Bazzan, M.; Beer, C.; Bejger, M.; Belahcene, I.; Belgin, M.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Billman, C. R.; Birch, J.; Birney, R.; Birnholtz, O.; Biscans, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackman, J.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Boer, M.; Bogaert, G.; Bohe, A.; Bondu, F.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brown, N. M.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Calderón Bustillo, J.; Callister, T. A.; Calloni, E.; Camp, J. B.; Canepa, M.; Cannon, K. C.; Cao, H.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Casanueva Diaz, J.; Casentini, C.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerboni Baiardi, L.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Cheeseboro, B. D.; Chen, H. Y.; Chen, Y.; Cheng, H.-P.; Chincarini, A.; Chiummo, A.; Chmiel, T.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, A. J. K.; Chua, S.; Chung, S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Cocchieri, C.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Collette, C. G.; Cominsky, L.; Constancio, M.; Conti, L.; Cooper, S. J.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J.-P.; Countryman, S. T.; Couvares, P.; Covas, P. B.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cullen, T. J.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dasgupta, A.; da Silva Costa, C. F.; Dattilo, V.; Dave, I.; Davier, M.; Davies, G. S.; Davis, D.; Daw, E. J.; Day, B.; Day, R.; de, S.; Debra, D.; Debreczeni, G.; Degallaix, J.; de Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dergachev, V.; De Rosa, R.; Derosa, R. T.; Desalvo, R.; Devine, R. C.; Dhurandhar, S.; Díaz, M. C.; di Fiore, L.; di Giovanni, M.; di Girolamo, T.; di Lieto, A.; di Pace, S.; di Palma, I.; di Virgilio, A.; Doctor, Z.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorrington, I.; Douglas, R.; Dovale Álvarez, M.; Downes, T. P.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Eisenstein, R. A.; Essick, R. C.; Etienne, Z.; Etzel, T.; Evans, M.; Evans, T. M.; Everett, R.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.; Farinon, S.; Farr, B.; Farr, W. M.; Fauchon-Jones, E. J.; Favata, M.; Fays, M.; Fehrmann, H.; Fejer, M. M.; Fernández Galiana, A.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Fiori, I.; Fiorucci, D.; Fisher, R. P.; Flaminio, R.; Fletcher, M.; Fong, H.; Forsyth, S. S.; Fournier, J.-D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fries, E. M.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H.; Gadre, B. U.; Gaebel, S. M.; Gair, J. R.; Gammaitoni, L.; Gaonkar, S. G.; Garufi, F.; Gaur, G.; Gayathri, V.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; George, J.; Gergely, L.; Germain, V.; Ghonge, S.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glaefke, A.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gonzalez Castro, J. M.; Gopakumar, A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Groot, P.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Hacker, J. J.; Hall, B. R.; Hall, E. D.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Healy, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Henry, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Hough, J.; Houston, E. A.; Howell, E. J.; Hu, Y. M.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Ingram, D. R.; Inta, R.; Isa, H. N.; Isac, J.-M.; Isi, M.; Isogai, T.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Junker, J.; Kalaghatgi, C. V.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kaur, T.; Kawabe, K.; Kéfélian, F.; Keitel, D.; Kelley, D. B.; Kennedy, R.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chunglee; Kim, J. C.; Kim, Whansun; Kim, W.; Kim, Y.-M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kirchhoff, R.; Kissel, J. S.; Klein, B.; Kleybolte, L.; Klimenko, S.; Koch, P.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Krämer, C.; Kringel, V.; Królak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kuo, L.; Kutynia, A.; Lackey, B. D.; Landry, M.; Lang, R. N.; Lange, J.; Lantz, B.; Lanza, R. K.; Lartaux-Vollard, A.; Lasky, P. D.; Laxen, M.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lebigot, E. O.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, K.; Lehmann, J.; Lenon, A.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levin, Y.; Li, T. G. F.; Libson, A.; Littenberg, T. B.; Liu, J.; Lockerbie, N. A.; Lombardi, A. L.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lovelace, G.; Lück, H.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macfoy, S.; Machenschalk, B.; Macinnis, M.; MacLeod, D. M.; Magaña-Sandoval, F.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A. S.; Maros, E.; Martelli, F.; Martellini, L.; Martin, I. W.; Martynov, D. V.; Mason, K.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McGrath, C.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McRae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Meidam, J.; Melatos, A.; Mendell, G.; Mendoza-Gandara, D.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Mezzani, F.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, A.; Miller, B. B.; Miller, J.; Millhouse, M.; Minenkov, Y.; Ming, J.; Mirshekari, S.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moggi, A.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, B. C.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Muniz, E. A. M.; Murray, P. G.; Mytidis, A.; Napier, K.; Nardecchia, I.; Naticchioni, L.; Nelemans, G.; Nelson, T. J. N.; Neri, M.; Nery, M.; Neunzert, A.; Newport, J. M.; Newton, G.; Nguyen, T. T.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Noack, A.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Oberling, J.; Ochsner, E.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; O'Shaughnessy, R.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pace, A. E.; Page, J.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Paris, H. R.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patricelli, B.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perez, C. J.; Perreca, A.; Perri, L. M.; Pfeiffer, H. P.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Post, A.; Powell, J.; Prasad, J.; Pratt, J. W. W.; Predoi, V.; Prestegard, T.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qi, H.; Qin, J.; Qiu, S.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rakhmanov, M.; Rapagnani, P.; Raymond, V.; Razzano, M.; Re, V.; Read, J.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Rew, H.; Reyes, S. D.; Rhoades, E.; Ricci, F.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, R.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sampson, L. M.; Sanchez, E. J.; Sandberg, V.; Sanders, J. R.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Sauter, O.; Savage, R. L.; Sawadsky, A.; Schale, P.; Scheuer, J.; Schmidt, E.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schönbeck, A.; Schreiber, E.; Schuette, D.; Schutz, B. F.; Schwalbe, S. G.; Scott, J.; Scott, S. M.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Setyawati, Y.; Shaddock, D. A.; Shaffer, T. J.; Shahriar, M. S.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, A.; Singer, L. P.; Singh, A.; Singh, R.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, B.; Smith, J. R.; Smith, R. J. E.; Son, E. J.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Spencer, A. P.; Srivastava, A. K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stephens, B. C.; Stevenson, S. P.; Stone, R.; Strain, K. A.; Straniero, N.; Stratta, G.; Strigin, S. E.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Sutton, P. J.; Swinkels, B. L.; Szczepańczyk, M. J.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tápai, M.; Taracchini, A.; Taylor, R.; Theeg, T.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thrane, E.; Tippens, T.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tomlinson, C.; Tonelli, M.; Tornasi, Z.; Torrie, C. I.; Töyrä, D.; Travasso, F.; Traylor, G.; Trifirò, D.; Trinastic, J.; Tringali, M. C.; Trozzo, L.; Tse, M.; Tso, R.; Turconi, M.; Tuyenbayev, D.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; van den Broeck, C.; Vander-Hyde, D. C.; van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Varma, V.; Vass, S.; Vasúth, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Venugopalan, G.; Verkindt, D.; Vetrano, F.; Viceré, A.; Viets, A. D.; Vinciguerra, S.; Vine, D. J.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Voss, D. V.; Vousden, W. D.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, M.; Wang, Y.; Ward, R. L.; Warner, J.; Was, M.; Watchi, J.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Weßels, P.; Westphal, T.; Wette, K.; Whelan, J. T.; Whiting, B. F.; Whittle, C.; Williams, D.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Worden, J.; Wright, J. L.; Wu, D. S.; Wu, G.; Yam, W.; Yamamoto, H.; Yancey, C. C.; Yap, M. J.; Yu, Hang; Yu, Haocun; Yvert, M.; Zadrożny, A.; Zangrando, L.; Zanolin, M.; Zendri, J.-P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, T.; Zhang, Y.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, S. J.; Zhu, X. J.; Zucker, M. E.; Zweizig, J.; ANTARES Collaboration

    2017-07-01

    The Advanced LIGO observatories detected gravitational waves from two binary black hole mergers during their first observation run (O1). We present a high-energy neutrino follow-up search for the second gravitational wave event, GW151226, as well as for gravitational wave candidate LVT151012. We find two and four neutrino candidates detected by IceCube, and one and zero detected by Antares, within ±500 s around the respective gravitational wave signals, consistent with the expected background rate. None of these neutrino candidates are found to be directionally coincident with GW151226 or LVT151012. We use nondetection to constrain isotropic-equivalent high-energy neutrino emission from GW151226, adopting the GW event's 3D localization, to less than 2 ×1 051- 2 ×1 054 erg .

  18. Development of a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a highly sensitive detection of enterovirus in the stool samples of acute flaccid paralysis cases

    PubMed Central

    2009-01-01

    Background In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. Methods A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. Results We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. Conclusions RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts. PMID:20015403

  19. Comparison of concentration methods for rapid detection of hookworm ova in wastewater matrices using quantitative PCR.

    PubMed

    Gyawali, P; Ahmed, W; Jagals, P; Sidhu, J P S; Toze, S

    2015-12-01

    Hookworm infection contributes around 700 million infections worldwide especially in developing nations due to increased use of wastewater for crop production. The effective recovery of hookworm ova from wastewater matrices is difficult due to their low concentrations and heterogeneous distribution. In this study, we compared the recovery rates of (i) four rapid hookworm ova concentration methods from municipal wastewater, and (ii) two concentration methods from sludge samples. Ancylostoma caninum ova were used as surrogate for human hookworm (Ancylostoma duodenale and Necator americanus). Known concentration of A. caninum hookworm ova were seeded into wastewater (treated and raw) and sludge samples collected from two wastewater treatment plants (WWTPs) in Brisbane and Perth, Australia. The A. caninum ova were concentrated from treated and raw wastewater samples using centrifugation (Method A), hollow fiber ultrafiltration (HFUF) (Method B), filtration (Method C) and flotation (Method D) methods. For sludge samples, flotation (Method E) and direct DNA extraction (Method F) methods were used. Among the four methods tested, filtration (Method C) method was able to recover higher concentrations of A. caninum ova consistently from treated wastewater (39-50%) and raw wastewater (7.1-12%) samples collected from both WWTPs. The remaining methods (Methods A, B and D) yielded variable recovery rate ranging from 0.2 to 40% for treated and raw wastewater samples. The recovery rates for sludge samples were poor (0.02-4.7), although, Method F (direct DNA extraction) provided 1-2 orders of magnitude higher recovery rate than Method E (flotation). Based on our results it can be concluded that the recovery rates of hookworm ova from wastewater matrices, especially sludge samples, can be poor and highly variable. Therefore, choice of concentration method is vital for the sensitive detection of hookworm ova in wastewater matrices. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  20. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE PAGES

    Godfrey, B.; Anderson, T.; Breedon, E.; ...

    2018-03-26

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  1. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godfrey, B.; Anderson, T.; Breedon, E.

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  2. Impairment in Emotional Modulation of Attention and Memory in Schizophrenia

    PubMed Central

    Walsh-Messinger, Julie; Ramirez, Paul Michael; Wong, Philip; Antonius, Daniel; Aujero, Nicole; McMahon, Kevin; Opler, Lewis A.; Malaspina, Dolores

    2014-01-01

    Emotion plays a critical role in cognition and goal-directed behavior via complex interconnections between the emotional and motivational systems. It has been hypothesized that the impairment in goal-directed behavior widely noted in schizophrenia may result from defects in the interaction between the neural (ventral) emotional system and (rostral) cortical processes. The present study examined the impact of emotion on attention and memory in schizophrenia. Twenty-five individuals with schizophrenia related psychosis and 25 healthy control subjects were administered a computerized task in which they were asked to search for target images during a rapid serial visual presentation of pictures. Target stimuli were either positive, negative, or neutral images presented at either 200ms or 700ms lag. Additionally, a visual hedonics task was used to assess differences between the schizophrenia group and controls on ratings of valence and arousal from the picture stimuli. Compared to controls, individuals with schizophrenia detected fewer emotional images under both the 200ms and 700ms lag conditions. Multivariate analyses showed that the schizophrenia group also detected fewer positive images under the 700 lag condition and fewer negative images under the 200 lag condition. Individuals with schizophrenia reported higher pleasantness and unpleasantness ratings than controls in response to neutral stimuli, while controls reported higher arousal ratings for neutral and positive stimuli compared to the schizophrenia group. These results highlight dysfunction in the neural modulation of emotion, attention, and cortical processing in schizophrenia, adding to the growing but mixed body of literature on emotion processing in the disorder. PMID:24910446

  3. Impairment in emotional modulation of attention and memory in schizophrenia.

    PubMed

    Walsh-Messinger, Julie; Ramirez, Paul Michael; Wong, Philip; Antonius, Daniel; Aujero, Nicole; McMahon, Kevin; Opler, Lewis A; Malaspina, Dolores

    2014-08-01

    Emotion plays a critical role in cognition and goal-directed behavior via complex interconnections between the emotional and motivational systems. It has been hypothesized that the impairment in goal-directed behavior widely noted in schizophrenia may result from defects in the interaction between the neural (ventral) emotional system and (rostral) cortical processes. The present study examined the impact of emotion on attention and memory in schizophrenia. Twenty-five individuals with schizophrenia related psychosis and 25 healthy control subjects were administered a computerized task in which they were asked to search for target images during a Rapid Serial Visual Presentation of pictures. Target stimuli were either positive or negative, or neutral images presented at either 200ms or 700ms lag. Additionally, a visual hedonic task was used to assess differences between the schizophrenia group and controls on ratings of valence and arousal from the picture stimuli. Compared to controls, individuals with schizophrenia detected fewer emotional images under both the 200ms and 700ms lag conditions. Multivariate analyses showed that the schizophrenia group also detected fewer positive images under the 700ms lag condition and fewer negative images under the 200ms lag condition. Individuals with schizophrenia reported higher pleasantness and unpleasantness ratings than controls in response to neutral stimuli, while controls reported higher arousal ratings for neutral and positive stimuli compared to the schizophrenia group. These results highlight dysfunction in the neural modulation of emotion, attention, and cortical processing in schizophrenia, adding to the growing but mixed body of literature on emotion processing in the disorder. Published by Elsevier B.V.

  4. Behaviour of oceanic 137Cs following the Fukushima Daiichi Nuclear Power Plant accident for four years simulated numerically by a regional ocean model

    NASA Astrophysics Data System (ADS)

    Tsumune, D.; Tsubono, T.; Aoyama, M.; Misumi, K.; Tateda, Y.

    2015-12-01

    A series of accidents at the Fukushima Dai-ichi Nuclear Power Plant (1F NPP) following the earthquake and tsunami of 11 March 2011 resulted in the release of radioactive materials to the ocean by two major pathways, direct release from the accident site and atmospheric deposition.We reconstructed spatiotemporal variability of 137Cs activity in the regional ocean for four years by numerical model, such as a regional scale and the North Pacific scale oceanic dispersion models, an atmospheric transport model, a sediment transport model, a dynamic biological compartment model for marine biota and river runoff model. Direct release rate of 137Cs were estimated for four years after the accident by comparing simulated results and observed activities very close to the site. The estimated total amounts of directly release was 3.6±0.7 PBq. Directly release rate of 137Cs decreased exponentially with time by the end of December 2012 and then, was almost constant. Decrease rate were quite small after 2013. The daily release rate of 137Cs was estimated to be the order of magnitude of 1010 Bq/day by the end of March 2015. The activity of directly released 137Cs was detectable only in the coastal zone after December 2012. Simulated 137Cs activities attributable to direct release were in good agreement with observed activities, a result that implies the estimated direct release rate was reasonable. There is no observed data of 137Cs activity in the ocean from 11 to 21 March 2011. Observed data of marine biota should reflect the history of 137Cs activity in this early period. We reconstructed the history of 137Cs activity in this early period by considering atmospheric deposition, river input, rain water runoff from the 1F NPP site. The comparisons between simulated 137Cs activity of marine biota by a dynamic biological compartment and observed data also suggest that simulated 137Cs activity attributable to atmospheric deposition was underestimated in this early period. The simulated river flux of 137Cs to the ocean did not effect on 137Cs activity in the ocean even if the parameters in this simulation have uncertainties because of the lack of observed data in rivers in the earlier period.

  5. Behaviour of oceanic 137Cs following the Fukushima Daiichi Nuclear Power Plant accident for four years simulated numerically by a regional ocean model

    NASA Astrophysics Data System (ADS)

    Torn, M. S.; Koven, C. D.; Riley, W. J.; Zhu, B.; Hicks Pries, C.; Phillips, C. L.

    2014-12-01

    A series of accidents at the Fukushima Dai-ichi Nuclear Power Plant (1F NPP) following the earthquake and tsunami of 11 March 2011 resulted in the release of radioactive materials to the ocean by two major pathways, direct release from the accident site and atmospheric deposition.We reconstructed spatiotemporal variability of 137Cs activity in the regional ocean for four years by numerical model, such as a regional scale and the North Pacific scale oceanic dispersion models, an atmospheric transport model, a sediment transport model, a dynamic biological compartment model for marine biota and river runoff model. Direct release rate of 137Cs were estimated for four years after the accident by comparing simulated results and observed activities very close to the site. The estimated total amounts of directly release was 3.6±0.7 PBq. Directly release rate of 137Cs decreased exponentially with time by the end of December 2012 and then, was almost constant. Decrease rate were quite small after 2013. The daily release rate of 137Cs was estimated to be the order of magnitude of 1010 Bq/day by the end of March 2015. The activity of directly released 137Cs was detectable only in the coastal zone after December 2012. Simulated 137Cs activities attributable to direct release were in good agreement with observed activities, a result that implies the estimated direct release rate was reasonable. There is no observed data of 137Cs activity in the ocean from 11 to 21 March 2011. Observed data of marine biota should reflect the history of 137Cs activity in this early period. We reconstructed the history of 137Cs activity in this early period by considering atmospheric deposition, river input, rain water runoff from the 1F NPP site. The comparisons between simulated 137Cs activity of marine biota by a dynamic biological compartment and observed data also suggest that simulated 137Cs activity attributable to atmospheric deposition was underestimated in this early period. The simulated river flux of 137Cs to the ocean did not effect on 137Cs activity in the ocean even if the parameters in this simulation have uncertainties because of the lack of observed data in rivers in the earlier period.

  6. [Detection of rifampicin concentration in cerebrospinal fluid by online enrichment and restricted-access media coupled with high-performance liquid chromatography].

    PubMed

    Yang, Xiaoping; Zhang, Xiaohui; Huang, Yanping; Wang, Rong; Xia, Hua; Li, Wenbin; Guo, YouMin

    2015-11-01

    To establish a method for detecting rifampicin in human cerebrospinal fluid (CSF) with restricted access media coupled with high-performance liquid chromatography that allows online direct sample injection and enrichment. We used the column of restricted access media as the pre-treatment column and a C18 column as the analytical column. The mobile phase of pre-treatment column was water-methanol (95:5,V/V) and the flow rate was 1 mL/min; the mobile phase of the analytical column was methanol-acetonitrile-10 mmol/L ammonuium acetate (volume ratio of 60:5:35). The detection wavelength was 254 nm and the column temperature was set at 25 degrees celsius;. For an injection volume of 100 µL, the peak area of rifampicin was 5.33 times that for an injection volume of 20 µL, and the limit of detection was effectively improved. The calibration curve showed an excellent linear relationship (r=0.9997) between rifampicin concentrations and peak areas within the concentration range of 0.25 to 8 µg/mL in CSF. The limits of detection and quantification was 0.07 µg/mL and 0.25 µg/mL, respecetively, with intra-day and inter-day assay precisions and relative standard deviation (RSD%) all below 5%. The recoveries of rifampicin at 3 blank spiked levels (low, medium, and high) ranged from 87.69% to 102.11%. In patients taking oral rifampicin at the dose of 10 mg/kg, the average rifampicin concentration was 0.29 in the CSF at 2 h after medication. The method we established is simple and fast for detecting rifampicin in CSF and allows direct online injection and enrichment with good detection precisions and accuracies.

  7. Nested PCR detection of malaria directly using blood filter paper samples from epidemiological surveys.

    PubMed

    Li, Peipei; Zhao, Zhenjun; Wang, Ying; Xing, Hua; Parker, Daniel M; Yang, Zhaoqing; Baum, Elizabeth; Li, Wenli; Sattabongkot, Jetsumon; Sirichaisinthop, Jeeraphat; Li, Shuying; Yan, Guiyun; Cui, Liwang; Fan, Qi

    2014-05-08

    Nested PCR is considered a sensitive and specific method for detecting malaria parasites and is especially useful in epidemiological surveys. However, the preparation of DNA templates for PCR is often time-consuming and costly. A simplified PCR method was developed to directly use a small blood filter paper square (2 × 2 mm) as the DNA template after treatment with saponin. This filter paper-based nested PCR method (FP-PCR) was compared to microscopy and standard nested PCR with DNA extracted by using a Qiagen DNA mini kit from filter paper blood spots of 204 febrile cases. The FP-PCR technique was further applied to evaluate malaria infections in 1,708 participants from cross-sectional epidemiological surveys conducted in Myanmar and Thailand. The FP-PCR method had a detection limit of ~0.2 parasites/μL blood, estimated using cultured Plasmodium falciparum parasites. With 204 field samples, the sensitivity of the FP-PCR method was comparable to that of the standard nested PCR method, which was significantly higher than that of microscopy. Application of the FP-PCR method in large cross-sectional studies conducted in Myanmar and Thailand detected 1.9% (12/638) and 6.2% (66/1,070) asymptomatic Plasmodium infections, respectively, as compared to the detection rates of 1.3% (8/638) and 0.04% (4/1,070) by microscopy. This FP-PCR method was much more sensitive than microscopy in detecting Plasmodium infections. It drastically increased the detection sensitivity of asymptomatic infections in cross-sectional surveys conducted in Thailand and Myanmar, suggesting that this FP-PCR method has a potential for future applications in malaria epidemiology studies.

  8. A Versatile Nanowire Platform for Highly Efficient Isolation and Direct PCR-free Colorimetric Detection of Human Papillomavirus DNA from Unprocessed Urine

    PubMed Central

    Lee, HyungJae; Choi, Mihye; Hwang, Sang-Hyun; Cho, Youngnam

    2018-01-01

    Purpose: As human papillomavirus (HPV) is primarily responsible for the development of cervical cancer, significant efforts have been devoted to develop novel strategies for detecting and identifying HPV DNA in urine. The analysis of target DNA sequences in urine offers a potential alternative to conventional methods as a non-invasive clinical screening and diagnostic assessment tool for the detection of HPV. However, the lack of efficient approaches to isolate and directly detect HPV DNA in urine has restricted its potential clinical use. In this study, we demonstrated a novel approach of using polyethylenimine-conjugated magnetic polypyrrole nanowires (PEI-mPpy NWs) for the extraction, identification, and PCR-free colorimetric detection of high-risk strains of HPV DNA sequences, particularly HPV-16 and HPV-18, in urine specimens of cervical cancer patients. Materials and Methods: We fabricated and characterized polyethylenimine-conjugated magnetic nanowires (PEI/mPpy NWs). PEI/mPpy NWs-based HPV DNA isolation and detection strategy appears to be a cost-effective and practical technology with greater sensitivity and accuracy than other urine-based methods. Results: The analytical and clinical performance of PEI-mPpy NWs was evaluated and compared with those of cervical swabs, demonstrating a superior type-specific concordance rate of 100% between urine and cervical swabs, even when using a small volume of urine (300 µL). Conclusion: We envision that PEI-mPpy NWs provide substantive evidence for clinical diagnosis and management of HPV-associated disease with their excellent performance in the recovery and detection of HPV DNA from minimal amounts of urine samples. PMID:29290816

  9. Directed area search using socio-biological vision algorithms and cognitive Bayesian reasoning

    NASA Astrophysics Data System (ADS)

    Medasani, S.; Owechko, Y.; Allen, D.; Lu, T. C.; Khosla, D.

    2010-04-01

    Volitional search systems that assist the analyst by searching for specific targets or objects such as vehicles, factories, airports, etc in wide area overhead imagery need to overcome multiple problems present in current manual and automatic approaches. These problems include finding targets hidden in terabytes of information, relatively few pixels on targets, long intervals between interesting regions, time consuming analysis requiring many analysts, no a priori representative examples or templates of interest, detecting multiple classes of objects, and the need for very high detection rates and very low false alarm rates. This paper describes a conceptual analyst-centric framework that utilizes existing technology modules to search and locate occurrences of targets of interest (e.g., buildings, mobile targets of military significance, factories, nuclear plants, etc.), from video imagery of large areas. Our framework takes simple queries from the analyst and finds the queried targets with relatively minimum interaction from the analyst. It uses a hybrid approach that combines biologically inspired bottom up attention, socio-biologically inspired object recognition for volitionally recognizing targets, and hierarchical Bayesian networks for modeling and representing the domain knowledge. This approach has the benefits of high accuracy, low false alarm rate and can handle both low-level visual information and high-level domain knowledge in a single framework. Such a system would be of immense help for search and rescue efforts, intelligence gathering, change detection systems, and other surveillance systems.

  10. Direct Zinc Determination in Brazilian Sugar Cane Spirit by Solid-Phase Extraction Using Moringa oleifera Husks in a Flow System with Detection by FAAS.

    PubMed

    Alves, Vanessa N; Borges, Simone S O; Coelho, Nivia M M

    2011-01-01

    This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extraction conditions were obtained using a sample pH of 4.0, a sample flow rate of 6.0 mL min(-1), 30.0 mg of sorbent mass, and 1.0 mol L(-1) HNO(3) as the eluent at a flow rate of 4.0 mL min(-1). The limit of detection for zinc was 1.9 μg L(-1), and the precision was below 0.82% (20.0 μg L(-1), n = 7). The analytical curve was linear from 2 to 50 μg L(-1), with a correlation coefficient of 0.9996. The method developed was successfully applied to spiked Brazilian sugar cane spirit, and accuracy was assessed through recovery tests, with results ranging from 83% to 100%.

  11. Direct Zinc Determination in Brazilian Sugar Cane Spirit by Solid-Phase Extraction Using Moringa oleifera Husks in a Flow System with Detection by FAAS

    PubMed Central

    Alves, Vanessa N.; Borges, Simone S. O.; Coelho, Nivia M. M.

    2011-01-01

    This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extraction conditions were obtained using a sample pH of 4.0, a sample flow rate of 6.0 mL min−1, 30.0 mg of sorbent mass, and 1.0 mol L−1 HNO3 as the eluent at a flow rate of 4.0 mL min−1. The limit of detection for zinc was 1.9 μg L−1, and the precision was below 0.82% (20.0 μg L−1, n = 7). The analytical curve was linear from 2 to 50 μg L−1, with a correlation coefficient of 0.9996. The method developed was successfully applied to spiked Brazilian sugar cane spirit, and accuracy was assessed through recovery tests, with results ranging from 83% to 100%. PMID:21785595

  12. Joint Denoising/Compression of Image Contours via Shape Prior and Context Tree

    NASA Astrophysics Data System (ADS)

    Zheng, Amin; Cheung, Gene; Florencio, Dinei

    2018-07-01

    With the advent of depth sensing technologies, the extraction of object contours in images---a common and important pre-processing step for later higher-level computer vision tasks like object detection and human action recognition---has become easier. However, acquisition noise in captured depth images means that detected contours suffer from unavoidable errors. In this paper, we propose to jointly denoise and compress detected contours in an image for bandwidth-constrained transmission to a client, who can then carry out aforementioned application-specific tasks using the decoded contours as input. We first prove theoretically that in general a joint denoising / compression approach can outperform a separate two-stage approach that first denoises then encodes contours lossily. Adopting a joint approach, we first propose a burst error model that models typical errors encountered in an observed string y of directional edges. We then formulate a rate-constrained maximum a posteriori (MAP) problem that trades off the posterior probability p(x'|y) of an estimated string x' given y with its code rate R(x'). We design a dynamic programming (DP) algorithm that solves the posed problem optimally, and propose a compact context representation called total suffix tree (TST) that can reduce complexity of the algorithm dramatically. Experimental results show that our joint denoising / compression scheme outperformed a competing separate scheme in rate-distortion performance noticeably.

  13. Fast shear compounding using robust 2-D shear wave speed calculation and multi-directional filtering.

    PubMed

    Song, Pengfei; Manduca, Armando; Zhao, Heng; Urban, Matthew W; Greenleaf, James F; Chen, Shigao

    2014-06-01

    A fast shear compounding method was developed in this study using only one shear wave push-detect cycle, such that the shear wave imaging frame rate is preserved and motion artifacts are minimized. The proposed method is composed of the following steps: 1. Applying a comb-push to produce multiple differently angled shear waves at different spatial locations simultaneously; 2. Decomposing the complex shear wave field into individual shear wave fields with differently oriented shear waves using a multi-directional filter; 3. Using a robust 2-D shear wave speed calculation to reconstruct 2-D shear elasticity maps from each filter direction; and 4. Compounding these 2-D maps from different directions into a final map. An inclusion phantom study showed that the fast shear compounding method could achieve comparable performance to conventional shear compounding without sacrificing the imaging frame rate. A multi-inclusion phantom experiment showed that the fast shear compounding method could provide a full field-of-view, 2-D and compounded shear elasticity map with three types of inclusions clearly resolved and stiffness measurements showing excellent agreement to the nominal values. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Fractal aspects of the flow and shear behaviour of free-flowable particle size fractions of pharmaceutical directly compressible excipient sorbitol.

    PubMed

    Hurychová, Hana; Lebedová, Václava; Šklubalová, Zdenka; Dzámová, Pavlína; Svěrák, Tomáš; Stoniš, Jan

    Flowability of powder excipients is directly influenced by their size and shape although the granulometric influence of the flow and shear behaviour of particulate matter is not studied frequently. In this work, the influence of particle size on the mass flow rate through the orifice of a conical hopper, and the cohesion and flow function was studied for four free-flowable size fractions of sorbitol for direct compression in the range of 0.080-0.400 mm. The particles were granulometricaly characterized using an optical microscopy; a boundary fractal dimension of 1.066 was estimated for regular sorbitol particles. In the particle size range studied, a non-linear relationship between the mean particle size and the mass flow rate Q10 (g/s) was detected having amaximum at the 0.245mm fraction. The best flow properties of this fraction were verified with aJenike shear tester due to the highest value of flow function and the lowest value of the cohesion. The results of this work show the importance of the right choice of the excipient particle size to achieve the best flow behaviour of particulate material.Key words: flowability size fraction sorbitol for direct compaction Jenike shear tester fractal dimension.

  15. Biosignatures in the Context of Low Energy Flux

    NASA Technical Reports Server (NTRS)

    Hoehler, T. M.

    2017-01-01

    Many of the features that are thought of as biosignatures - including the mediation of chemical and physical processes with speed, specificity, and selectivity - result directly or indirectly from life's unique capability to mediate and direct energy flux. As such, it is important to consider the impact that differences in energy flux may have on the quantity and quality of evidence for life. Earth differs from every other body in our solar system in the magnitude of biologically-usable energy flux into a liquid water environment. On a global basis, the capture of light energy into photosynthesis and the flux of chemical energy represented in the products of that photosynthesis (organic material + O2) are about six and four orders of magnitude larger, respectively, than the flux of energy represented in geochemical sources. Our conception of what an inhabited world "looks like" and our intuition about how to search for life are based in this high-energy context. Energy fluxes on worlds beyond Earth may be better approximated by the million-fold smaller flux provided to Earth's biosphere by geochemical sources. As a result, the nature, abundance, and quality of evidence for life that could be expected on an inhabited extraterrestrial world within our solar system may differ profoundly from that found on Earth. Understanding this potential difference in quantitative terms provides important context for the formulation of life detection strategies. The influence of energy flux on biosignatures can be evaluated through reference to the two basic purposes into which life partitions energy flux: (1) Life expends energy to sustain existing biomass in a metabolic steady state (metabolically functional but non-growing). The formal representation of this relationship in the traditional microbiology literature equates biomass directly with energy flux. The direct implication is that worlds having lower energy flux will have correspondingly lower potential to support biomass. Life detection strategies that directly target extant organisms should therefore be prepared to encounter average biomass densities that may be many orders of magnitude smaller than those found in most of Earth's surface environments (2) Life expends energy to synthesize new biomass. An end-member case in which new biomass is created at the energy-limited rate and the corresponding cells are immediately destroyed (so that the energy partitioned to cell maintenance is minimized) establishes an upper bound on the rate at which biological material can enter a bulk global pool. For a specified bulk concentration [i] of any particular biological compound, i, or for biologically produced matter overall, this synthesis rate, R (sub i), defines a characteristic time scale tau (sub i) equals [i] divided by R (sub i). tau (sub i) can be thought of as (a) the minimum time required for biosynthesis to yield a specific bulk concentration (e.g., a detection threshold) of i, and (b) the average residence time of i within a bulk pool when [i] is held in steady state through a balance between biosynthesis and attrition by physical, chemical, or biological consumption. tau (sub i) becomes an important quantity in considering the potential utility of enantiomeric excess (as a product of homochiral biosynthesis) as a biosignature. Spontaneous racemization of amino acids acts to "erase" the signature of homochiral synthesis over time scales that may range from hundreds to hundreds of thousands of years, depending on temperature. For environments in which low energy flux translates to low rates of biosynthesis, including the synthesis of homochiral amino acids, amino acid residence times in pools having detectable concentrations may compare to or significantly exceed the time scale for racemization. This and similar consequences of long residence times should be considered in the formulation of life detection strategies based on detection of biologically-produced species. Fluxes of biologically-useful energy on potentially habitable worlds within our solar system are, at present, not well constrained. Improving such constraint has the potential to inform priorities in the formulation and targeting of search-for-life strategies, based on the implications of energy flux for the abundance and quality of biosignatures overall, and in specific categories.

  16. Molecular detection of Toxoplasma gondii in snakes.

    PubMed

    Nasiri, Vahid; Teymurzadeh, Shohreh; Karimi, Gholamreza; Nasiri, Mehdi

    2016-10-01

    Toxoplasma gondii, an obligate intracellular protozoan parasite, is responsible for one of the most common zoonotic parasitic diseases in almost all warm-blooded vertebrates worldwide, and it is estimated that about one-third of the world human population is chronically infected with this parasite. Little is known about the circulation of T. gondii in snakes and this study for the first time aimed to evaluate the infection rates of snakes by this parasite by PCR methods. The brain of 68 Snakes, that were collected between May 2012 and September 2015 and died after the hold in captivity, under which they were kept for taking poisons, were examined for the presence of this parasite. DNA was extracted and Nested-PCR method was carried out with two of pairs of primers to detect the 344 bp fragment of T. gondii GRA6 gene. Five positive nested-PCR products were directly sequenced in the forward and reverse directions by Sequetech Company (Mountain View, CA). T. gondii GRA6 gene were detected from 55 (80.88%) of 68 snakes brains. Sequencing of the GRA6 gene revealed 98-100% of similarity with T. gondii sequences deposited in GenBank. To our knowledge, this is the first study of molecular detection of T. gondii in snakes and our findings show a higher frequency of this organism among them. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Detection of Nonvolatile Inorganic Oxidizer-Based Explosives from Wipe Collections by Infrared Thermal Desorption-Direct Analysis in Real Time Mass Spectrometry.

    PubMed

    Forbes, Thomas P; Sisco, Edward; Staymates, Matthew

    2018-05-07

    Infrared thermal desorption (IRTD) was coupled with direct analysis in real time mass spectrometry (DART-MS) for the detection of both inorganic and organic explosives from wipe collected samples. This platform generated discrete and rapid heating rates that allowed volatile and semivolatile organic explosives to thermally desorb at relatively lower temperatures, while still achieving elevated temperatures required to desorb nonvolatile inorganic oxidizer-based explosives. IRTD-DART-MS demonstrated the thermal desorption and detection of refractory potassium chlorate and potassium perchlorate oxidizers, compounds difficult to desorb with traditional moderate-temperature resistance-based thermal desorbers. Nanogram to sub-nanogram sensitivities were established for analysis of a range of organic and inorganic oxidizer-based explosive compounds, with further enhancement limited by the thermal properties of the most common commercial wipe materials. Detailed investigations and high-speed visualization revealed conduction from the heated glass-mica base plate as the dominant process for heating of the wipe and analyte materials, resulting in thermal desorption through boiling, aerosolization, and vaporization of samples. The thermal desorption and ionization characteristics of the IRTD-DART technique resulted in optimal sensitivity for the formation of nitrate adducts with both organic and inorganic species. The IRTD-DART-MS coupling and IRTD in general offer promising explosive detection capabilities to the defense, security, and law enforcement arenas.

  18. Scale and Sampling Effects on Floristic Quality

    PubMed Central

    2016-01-01

    Floristic Quality Assessment (FQA) is increasingly influential for making land management decisions, for directing conservation policy, and for research. But, the basic ecological properties and limitations of its metrics are ill defined and not well understood–especially those related to sample methods and scale. Nested plot data from a remnant tallgrass prairie sampled annually over a 12-year period, were used to investigate FQA properties associated with species detection rates, species misidentification rates, sample year, and sample grain/area. Plot size had no apparent effect on Mean C (an area’s average Floristic Quality level), nor did species detection levels above 65% detection. Simulated species misidentifications only affected Mean C values at greater than 10% in large plots, when the replaced species were randomly drawn from the broader county-wide species pool. Finally, FQA values were stable over the 12-year study, meaning that there was no evidence that the metrics exhibit year effects. The FQA metric Mean C is demonstrated to be robust to varied sample methodologies related to sample intensity (plot size, species detection rate), as well as sample year. These results will make FQA measures even more appealing for informing land-use decisions, policy, and research for two reasons: 1) The sampling effort needed to generate accurate and consistent site assessments with FQA measures is shown to be far lower than what has previously been assumed, and 2) the stable properties and consistent performance of metrics with respect to sample methods will allow for a remarkable level of comparability of FQA values from different sites and datasets compared to other commonly used ecological metrics. PMID:27489959

  19. Automatic characterization of sleep need dissipation dynamics using a single EEG signal.

    PubMed

    Garcia-Molina, Gary; Bellesi, Michele; Riedner, Brady; Pastoor, Sander; Pfundtner, Stefan; Tononi, Giulio

    2015-01-01

    In the two-process model of sleep regulation, slow-wave activity (SWA, i.e. the EEG power in the 0.5-4 Hz frequency band) is considered a direct indicator of sleep need. SWA builds up during non-rapid eye movement (NREM) sleep, declines before the onset of rapid-eye-movement (REM) sleep, remains low during REM and the level of increase in successive NREM episodes gets progressively lower. Sleep need dissipates with a speed that is proportional to SWA and can be characterized in terms of the initial sleep need, and the decay rate. The goal in this paper is to automatically characterize sleep need from a single EEG signal acquired at a frontal location. To achieve this, a highly specific and reasonably sensitive NREM detection algorithm is proposed that leverages the concept of a single-class Kernel-based classifier. Using automatic NREM detection, we propose a method to estimate the decay rate and the initial sleep need. This method was tested on experimental data from 8 subjects who recorded EEG during three nights at home. We found that on average the estimates of the decay rate and the initial sleep need have higher values when automatic NREM detection was used as compared to manual NREM annotation. However, the average variability of these estimates across multiple nights of the same subject was lower when the automatic NREM detection classifier was used. While this method slightly over estimates the sleep need parameters, the reduced variability across subjects makes it more effective for within subject statistical comparisons of a given sleep intervention.

  20. Direct identification of Streptococcus agalactiae and capsular type by real-time PCR in vaginal swabs from pregnant women.

    PubMed

    Morozumi, Miyuki; Chiba, Naoko; Igarashi, Yuko; Mitsuhashi, Naoki; Wajima, Takeaki; Iwata, Satoshi; Ubukata, Kimiko

    2015-01-01

    Most group B streptococcus (GBS) infections in newborns are with capsular type Ia, Ib, or III. To prevent these infections more effectively, we developed a real-time PCR method to simultaneously detect GBS species and identify these 3 capsular types in vaginal swab samples from women at 36-39 weeks of gestation. DNA to be detected included those of the dltS gene (encoding a histidine kinase specific to GBS) and cps genes encoding capsular types. PCR sensitivity was 10 CFU/well for a 33-35 threshold cycle. Results were obtained within 2 h. Direct PCR results were compared with results obtained from cultures. Samples numbering 1226 underwent PCR between September 2008 and August 2012. GBS positivity rates by direct PCR and after routine culture were 15.7% (n = 192) and 12.6% (n = 154), respectively. Sensitivity and specificity of direct PCR relative to culture were 96.1% and 95.9%. Of GBS positive samples identified by PCR, capsular types determined directly by real-time PCR were Ia (n = 24), Ib (n = 32), and III (n = 26). Real-time PCR using our designed cycling probe is a practical, highly sensitive method for identification of GBS in pregnant carriers, allowing use of prophylactic intrapartum antibiotics in time to cover the possibility of unexpected premature birth. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  1. A randomized, prospective cross-over trial comparing methylene blue-directed biopsy and conventional random biopsy for detecting intestinal metaplasia and dysplasia in Barrett's esophagus.

    PubMed

    Ragunath, K; Krasner, N; Raman, V S; Haqqani, M T; Cheung, W Y

    2003-12-01

    The value of methylene blue-directed biopsies (MBDB) in detecting specialized intestinal metaplasia and dysplasia in Barrett's esophagus remains unclear. The aim of this study was to compare the accuracy of MBDB with random biopsy in detecting intestinal metaplasia and dysplasia in patients with Barrett's esophagus. A prospective, randomized, cross-over trial was undertaken to compare MBDB with random biopsy in patients with Barrett's esophagus segments 3 cm or more in length without macroscopic evidence of dysplasia or cancer. Dysplasia was graded as: indefinite for dysplasia, low-grade dysplasia, high-grade dysplasia, or carcinoma, and was reported in a blinded fashion. Fifty-seven patients were recruited, 44 of whom were male. A total of 1,269 biopsies were taken (MBDB-651, random biopsie-618). Analysis of the results by per-biopsy protocol showed that the MBDB technique diagnosed significantly more specialized intestinal metaplasia (75 %) compared to the random biopsy technique (68 %; P = 0.032). The sensitivity and specificity rates of MBDB for diagnosing specialized intestinal metaplasia were 91 % (95 % CI, 88 - 93 %) and 43 % (95 % CI, 36 - 51 %), respectively. The sensitivity and specificity rates of MBDB for diagnosing dysplasia or carcinoma were 49 % (95 % CI, 38 - 61 %) and 85 % (95 % CI, 82 - 88 %), respectively. There were no significant differences in the diagnosis of dysplasia and carcinoma - MBDB 12 %, random biopsy 10 %. The methylene blue staining pattern appeared to have an influence on the detection of specialized intestinal metaplasia and dysplasia/carcinoma. Dark blue staining was associated with increased detection of specialized intestinal metaplasia (P < 0.0001), and heterogeneous staining (P = 0.137) or no staining (P = 0.005) were associated with dysplasia and/or carcinoma detection. The MBDB technique prolonged the endoscopy examination by an average of 6 min. The diagnostic accuracy of the MBDB technique was superior to that of the random biopsy technique for identifying specialized intestinal metaplasia, but not dysplasia or carcinoma. The intensity of methylene blue staining has an influence on the detection of specialized intestinal metaplasia and dysplasia or carcinoma, which may help in targeting the biopsies. Although MBDB prolongs the endoscopy procedure slightly, it is a safe and well-tolerated procedure. Further clinical studies on the MBDB technique exclusively in endoscopically normal dysplastic Barrett's esophagus are needed.

  2. Comparison of remote video and diver's direct observations to quantify reef fishes feeding on benthos in coral and rocky reefs.

    PubMed

    Longo, G O; Floeter, S R

    2012-10-01

    This study compared remote underwater video and traditional direct diver observations to assess reef fish feeding impact on benthos across multiple functional groups within different trophic categories (e.g. herbivores, zoobenthivores and omnivores) and in two distinct reef systems: a subtropical rocky reef and a tropical coral reef. The two techniques were roughly equivalent, both detecting the species with higher feeding impact and recording similar bite rates, suggesting that reef fish feeding behaviour at the study areas are not strongly affected by the diver's presence. © 2012 The Authors. Journal of Fish Biology © 2012 The Fisheries Society of the British Isles.

  3. Preliminary design study of a regenerative life support system information management and display system

    NASA Technical Reports Server (NTRS)

    Parker, C. D.; Tommerdahl, J. B.

    1972-01-01

    The instrumentation requirements for a regenerative life support systems were studied to provide the earliest possible indication of a malfunction that will permit degradation of the environment. Four categories of parameters were investigated: environmental parameters that directly and immediately influence the health and safety of the cabin crew; subsystems' inputs to the cabin that directly maintain the cabin environmental parameters; indications for maintenance or repair; and parameters useful as diagnostic indicators. A data averager concept is introduced which provides a moving average of parameter values that is not influenced by spurious changes, and is convenient for detecting parameter rates of change. A system is included to provide alarms at preselected parameter levels.

  4. A self-triggered picoinjector in microfluidics

    NASA Astrophysics Data System (ADS)

    Yang, Yiming; Liu, Songsheng; Jia, Chunping; Mao, Hongju; Jin, Qinghui; Zhao, Jianlong; Zhou, Hongbo

    2016-12-01

    Droplet-based microfluidics has recently emerged as a potential platform for studies of single-cell, directed evolution, and genetic sequencing. In droplet-based microfluidics, adding reagents into drops is one of the most important functions. In this paper, we develop a new self-triggered picoinjector to add controlled volumes of reagent into droplets at kilohertz rates. In the picoinjector, the reagent injecting is triggered by the coming droplet itself, without needing a droplet detection module. Meanwhile, the dosing volume can be precisely controlled. These features make the system more practical and reliable. We expect the new picoinjector will find important applications of droplet-based microfluidics in automated biological assay, directed evolution, enzyme assay, and so on.

  5. Direct impression on agar surface as a diagnostic sampling procedure for candida balanitis.

    PubMed

    Lisboa, Carmen; Santos, António; Azevedo, Filomena; Pina-Vaz, Cidália; Rodrigues, Acácio Gonçalves

    2010-02-01

    The diagnosis of candida balanitis should be based upon both clinical and mycological data. The procedure of material collection is a critical issue to confirm or rule out the clinical diagnosis of candida balanitis. To compare direct impression of the glans on the agar surface of solid culture media with the collection of genital exudates with cotton swab for the diagnosis of candida balanitis. A prospective cross-sectional study was carried out during a 36-month period. Sexually transmitted disease clinic attendees with balanitis and asymptomatic men were included. Specimens for yeast culture were collected from the glans penis and inner preputial layer using the direct impression on CHROMagar candida medium and by swabbing with a sterile cotton swab. Among 478 men enrolled, 189 had balanitis. The prevalence of candida balanitis was 17.8% (85/478) confirmed after culture by direct impression; the swab method detected only 54/85 (63.5%) of these men. Of the 289 asymptomatic men, 36 (12.5%) yielded Candida spp; the swab method detected only 38.9% of these men. The risk of having candida balanitis is 8.9 (IC 95% 2.48 to 32.04) whenever the number of candida colonies recovered by direct impression was greater than 10. Direct impression on CHROMagar candida medium resulted in the highest Candida spp recovery rate. More than 10 colonies yielded by impression culture were statistically associated with candida balanitis. This method shows the ideal profile for sampling the male genital area for yeasts and should be included in the management of balanitis.

  6. The Influence of HIV on the Evolution of Mycobacterium tuberculosis

    PubMed Central

    Brites, Daniela; Stucki, David; Evans, Joanna C.; Seldon, Ronnett; Heekes, Alexa; Mulder, Nicola; Nicol, Mark; Oni, Tolu; Mizrahi, Valerie; Warner, Digby F.; Parkhill, Julian; Gagneux, Sebastien; Martin, Darren P.; Wilkinson, Robert J.

    2017-01-01

    Abstract HIV significantly affects the immunological environment during tuberculosis coinfection, and therefore may influence the selective landscape upon which M. tuberculosis evolves. To test this hypothesis whole genome sequences were determined for 169 South African M. tuberculosis strains from HIV-1 coinfected and uninfected individuals and analyzed using two Bayesian codon-model based selection analysis approaches: FUBAR which was used to detect persistent positive and negative selection (selection respectively favoring and disfavoring nonsynonymous substitutions); and MEDS which was used to detect episodic directional selection specifically favoring nonsynonymous substitutions within HIV-1 infected individuals. Among the 25,251 polymorphic codon sites analyzed, FUBAR revealed that 189-fold more were detectably evolving under persistent negative selection than were evolving under persistent positive selection. Three specific codon sites within the genes celA2b, katG, and cyp138 were identified by MEDS as displaying significant evidence of evolving under directional selection influenced by HIV-1 coinfection. All three genes encode proteins that may indirectly interact with human proteins that, in turn, interact functionally with HIV proteins. Unexpectedly, epitope encoding regions were enriched for sites displaying weak evidence of directional selection influenced by HIV-1. Although the low degree of genetic diversity observed in our M. tuberculosis data set means that these results should be interpreted carefully, the effects of HIV-1 on epitope evolution in M. tuberculosis may have implications for the design of M. tuberculosis vaccines that are intended for use in populations with high HIV-1 infection rates. PMID:28369607

  7. Structure Line Detection from LIDAR Point Clouds Using Topological Elevation Analysis

    NASA Astrophysics Data System (ADS)

    Lo, C. Y.; Chen, L. C.

    2012-07-01

    Airborne LIDAR point clouds, which have considerable points on object surfaces, are essential to building modeling. In the last two decades, studies have developed different approaches to identify structure lines using two main approaches, data-driven and modeldriven. These studies have shown that automatic modeling processes depend on certain considerations, such as used thresholds, initial value, designed formulas, and predefined cues. Following the development of laser scanning systems, scanning rates have increased and can provide point clouds with higher point density. Therefore, this study proposes using topological elevation analysis (TEA) to detect structure lines instead of threshold-dependent concepts and predefined constraints. This analysis contains two parts: data pre-processing and structure line detection. To preserve the original elevation information, a pseudo-grid for generating digital surface models is produced during the first part. The highest point in each grid is set as the elevation value, and its original threedimensional position is preserved. In the second part, using TEA, the structure lines are identified based on the topology of local elevation changes in two directions. Because structure lines can contain certain geometric properties, their locations have small relieves in the radial direction and steep elevation changes in the circular direction. Following the proposed approach, TEA can be used to determine 3D line information without selecting thresholds. For validation, the TEA results are compared with those of the region growing approach. The results indicate that the proposed method can produce structure lines using dense point clouds.

  8. Familiarity breeds contempt: combining proximity loggers and GPS reveals female white-tailed deer (Odocoileus virginianus) avoiding close contact with neighbors.

    PubMed

    Tosa, Marie I; Schauber, Eric M; Nielsen, Clayton K

    2015-01-01

    Social interactions can influence infectious disease dynamics, particularly for directly transmitted pathogens. Therefore, reliable information on contact frequency within and among groups can better inform disease modeling and management. We compared three methods of assessing contact patterns: (1) space-use overlap (volume of interaction [VI]), (2) direct contact rates measured by simultaneous global positioning system (GPS) locations (<10 m apart), and (3) direct contact rates measured by proximity loggers (PLs; 1-m detection) among female white-tailed deer (Odocoileus virginianus). We calculated the PL∶GPS contact ratios to see whether both devices reveal similar contact patterns and thus predict similar pathogen transmission patterns. Contact rates measured by GPS and PLs were similarly high for two within-group dyads (pairs of deer in the same social groups). Dyads representing separate but neighboring groups (high VI) had PL∶GPS contact ratios near zero, whereas dyads further apart (intermediate VI) had higher PL∶GPS contact ratios. Social networks based on PL contacts showed the fewest connected individuals and lowest mean centrality measures; network metrics were intermediate when based on GPS contacts and greatest when based on VI. Thus, the VI network portrayed animals to be more uniformly and strongly connected than did the PL network. We conclude that simultaneous GPS locations, compared with PLs, substantially underestimate the impact of group membership on direct contact rates of female deer and make networks appear more connected. We also present evidence that deer coming within the general vicinity of each other are less likely to come in close contact if they are in neighboring social groups than deer whose home ranges overlap little if at all. Combined, these results provide evidence that direct transmission of disease agents among female and juvenile white-tailed deer is likely to be constrained both spatially and by social structure, more so than GPS data alone would suggest.

  9. Sulfenic acid chemistry, detection and cellular lifetime☆

    PubMed Central

    Gupta, Vinayak; Carroll, Kate S.

    2014-01-01

    Background Reactive oxygen species-mediated cysteine sulfenic acid modification has emerged as an important regulatory mechanism in cell signaling. The stability of sulfenic acid in proteins is dictated by the local microenvironment and ability of antioxidants to reduce this modification. Several techniques for detecting this cysteine modification have been developed, including direct and in situ methods. Scope of review This review presents a historical discussion of sulfenic acid chemistry and highlights key examples of this modification in proteins. A comprehensive survey of available detection techniques with advantages and limitations is discussed. Finally, issues pertaining to rates of sulfenic acid formation, reduction, and chemical trapping methods are also covered. Major conclusions Early chemical models of sulfenic acid yielded important insights into the unique reactivity of this species. Subsequent pioneering studies led to the characterization of sulfenic acid formation in proteins. In parallel, the discovery of oxidant-mediated cell signaling pathways and pathological oxidative stress has led to significant interest in methods to detect these modifications. Advanced methods allow for direct chemical trapping of protein sulfenic acids directly in cells and tissues. At the same time, many sulfenic acids are short-lived and the reactivity of current probes must be improved to sample these species, while at the same time, preserving their chemical selectivity. Inhibitors with binding scaffolds can be rationally designed to target sulfenic acid modifications in specific proteins. General significance Ever increasing roles for protein sulfenic acids have been uncovered in physiology and pathology. A more complete understanding of sulfenic acid-mediated regulatory mechanisms will continue to require rigorous and new chemical insights. This article is part of a Special Issue entitled Current methods to study reactive oxygen species - pros and cons and biophysics of membrane proteins. Guest Editor: Christine Winterbourn. PMID:23748139

  10. Metabolism of fatty acids and lipid hydroperoxides in human body monitoring with Fourier transform Infrared Spectroscopy.

    PubMed

    Yoshida, Satoshi; Zhang, Qin-Zeng; Sakuyama, Shu; Matsushima, Satoshi

    2009-07-24

    The metabolism of dietary fatty acids in human has been measured so far using human blood cells and stable-isotope labeled fatty acids, however, no direct data was available for human peripheral tissues and other major organs. To realize the role of dietary fatty acids in human health and diseases, it would be eager to develop convenient and suitable method to monitor fatty acid metabolism in human. We have developed the measurement system in situ for human lip surface lipids using the Fourier transform infrared spectroscopy (FTIR) - attenuated total reflection (ATR) detection system with special adaptor to monitor metabolic changes of lipids in human body. As human lip surface lipids may not be much affected by skin sebum constituents and may be affected directly by the lipid constituents of diet, we could detect changes of FTIR-ATR spectra, especially at 3005 to approximately 3015 cm(-1), of lip surface polyunsaturated fatty acids in a duration time-dependent manner after intake of the docosahexaenoic acid (DHA)-containing triglyceride diet. The ingested DHA appeared on the lip surface and was detected by FTIR-ATR directly and non-invasively. It was found that the metabolic rates of DHA for male volunteer subjects with age 60s were much lower than those with age 20s. Lipid hydroperoxides were found in lip lipids which were extracted from the lip surface using a mixture of ethanol/ethylpropionate/iso-octane solvents, and were the highest in the content just before noon. The changes of lipid hydroperoxides were detected also in situ with FTIR-ATR at 968 cm(-1). The measurements of lip surface lipids with FTIR-ATR technique may advance the investigation of human lipid metabolism in situ non-invasively.

  11. Internalization and dissemination of human norovirus and Tulane virus in fresh produce is plant dependent.

    PubMed

    Yang, Zhihong; Chambers, Heather; DiCaprio, Erin; Gao, Gary; Li, Jianrong

    2018-02-01

    Human norovirus (NoV) is a leading cause of fresh produce associated outbreaks. Previous research indicates that the roots of growing leafy greens and berries internalize human NoV. However the effect of plant type and inoculum level on internalization rates has not been directly compared. In this study we compared the internalization and dissemination rates of human NoV and its surrogate, Tulane virus (TV) in green onion, radishes, and Romaine lettuce. We also evaluated the effect inoculum level and plant growth matrix on the rate of viral internalization. In the hydroponic growth system, we detected internalization and dissemination of human NoV RNA in green onions. In hydroponically growing green onions inoculated with high titer TV, we found higher rates of internalization and dissemination compared to green onions inoculated with low titer TV. In soil growth systems, no infectious TV was detected in either green onion or radishes. However, in Romaine lettuce plants grown in soil approximately 4 log 10  PFU/g was recovered from all tissues on day 14 p.i. Overall, we found that the type of plant, growth matrix, and the inoculum level influences the internalization and dissemination of human NoV and TV. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Non-Invasive Detection of Respiration and Heart Rate with a Vehicle Seat Sensor.

    PubMed

    Wusk, Grace; Gabler, Hampton

    2018-05-08

    This study demonstrates the feasibility of using a seat sensor designed for occupant classification from a production passenger vehicle to measure an occupant’s respiration rate (RR) and heart rate (HR) in a laboratory setting. Relaying occupant vital signs after a crash could improve emergency response by adding a direct measure of the occupant state to an Advanced Automatic Collision Notification (AACN) system. Data was collected from eleven participants with body weights ranging from 42 to 91 kg using a Ford Mustang passenger seat and seat sensor. Using a ballistocardiography (BCG) approach, the data was processed by time domain filtering and frequency domain analysis using the fast Fourier transform to yield RR and HR in a 1-min sliding window. Resting rates over the 30-min data collection and continuous RR and HR signals were compared to laboratory physiological instruments using the Bland-Altman approach. Differences between the seat sensor and reference sensor were within 5 breaths per minute for resting RR and within 15 beats per minute for resting HR. The time series comparisons for RR and HR were promising with the frequency analysis technique outperforming the peak detection technique. However, future work is necessary for more accurate and reliable real-time monitoring of RR and HR outside the laboratory setting.

  13. Actinometric measurements and theoretical calculations of j/O3/, the rate of photolysis of ozone to O/1D/

    NASA Technical Reports Server (NTRS)

    Dickerson, R. R.; Stedman, D. H.; Chameides, W. L.; Crutzen, P. J.; Fishman, J.

    1979-01-01

    The paper presents an experimental technique which measures j/O3-O(1-D)/, the rate of solar photolysis of ozone to singlet oxygen atoms. It is shown that a flow actinometer carries dilute O3 in N2O into direct sunlight where the O(1D) formed reacts with N2O to form NO which chemiluminescence detects, with a time resolution of about one minute. Measurements indicate a photolysis rate of 1.2 (+ or - .2) x 10 to the -5/s for a cloudless sky, 45 deg zenith angle, 0.345 cm ozone column and zero albedo. Finally, ground level results compare with theoretical calculations based on the UV actinic flux as a function of ozone column and solar zenith angle.

  14. Rapid mapping of polarization switching through complete information acquisition

    DOE PAGES

    Somnath, Suhas; Belianinov, Alex; Kalinin, Sergei V.; ...

    2016-12-02

    Polarization switching in ferroelectric and multiferroic materials underpins a broad range of current and emergent applications, ranging from random access memories to field-effect transistors, and tunnelling devices. Switching in these materials is exquisitely sensitive to local defects and microstructure on the nanometre scale, necessitating spatially resolved high-resolution studies of these phenomena. Classical piezoresponse force microscopy and spectroscopy, although providing necessary spatial resolution, are fundamentally limited in data acquisition rates and energy resolution. This limitation stems from their two-tiered measurement protocol that combines slow (~1 s) switching and fast (~10 kHz–1 MHz) detection waveforms. Here we develop an approach for rapidmore » probing of ferroelectric switching using direct strain detection of material response to probe bias. This approach, facilitated by high-sensitivity electronics and adaptive filtering, enables spectroscopic imaging at a rate 3,504 times faster the current state of the art, achieving high-veracity imaging of polarization dynamics in complex microstructures.« less

  15. On the single-photon-counting (SPC) modes of imaging using an XFEL source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhehui

    In this study, the requirements to achieve high detection efficiency (above 50%) and gigahertz (GHz) frame rate for the proposed 42-keV X-ray free-electron laser (XFEL) at Los Alamos are summarized. Direct detection scenarios using C (diamond), Si, Ge and GaAs semiconductor sensors are analyzed. Single-photon counting (SPC) mode and weak SPC mode using Si can potentially meet the efficiency and frame rate requirements and be useful to both photoelectric absorption and Compton physics as the photon energy increases. Multilayer three-dimensional (3D) detector architecture, as a possible means to realize SPC modes, is compared with the widely used two-dimensional (2D) hybridmore » planar electrode structure and 3D deeply entrenched electrode architecture. Demonstration of thin film cameras less than 100-μm thick with onboard thin ASICs could be an initial step to realize multilayer 3D detectors and SPC modes for XFELs.« less

  16. On the single-photon-counting (SPC) modes of imaging using an XFEL source

    DOE PAGES

    Wang, Zhehui

    2015-12-14

    In this study, the requirements to achieve high detection efficiency (above 50%) and gigahertz (GHz) frame rate for the proposed 42-keV X-ray free-electron laser (XFEL) at Los Alamos are summarized. Direct detection scenarios using C (diamond), Si, Ge and GaAs semiconductor sensors are analyzed. Single-photon counting (SPC) mode and weak SPC mode using Si can potentially meet the efficiency and frame rate requirements and be useful to both photoelectric absorption and Compton physics as the photon energy increases. Multilayer three-dimensional (3D) detector architecture, as a possible means to realize SPC modes, is compared with the widely used two-dimensional (2D) hybridmore » planar electrode structure and 3D deeply entrenched electrode architecture. Demonstration of thin film cameras less than 100-μm thick with onboard thin ASICs could be an initial step to realize multilayer 3D detectors and SPC modes for XFELs.« less

  17. Mass-transport limitations in spot-based microarrays.

    PubMed

    Zhao, Ming; Wang, Xuefeng; Nolte, David

    2010-09-20

    Mass transport of analyte to surface-immobilized affinity reagents is the fundamental bottleneck for sensitive detection in solid-support microarrays and biosensors. Analyte depletion in the volume adjacent to the sensor causes deviation from ideal association, significantly slows down reaction kinetics, and causes inhomogeneous binding across the sensor surface. In this paper we use high-resolution molecular interferometric imaging (MI2), a label-free optical interferometry technique for direct detection of molecular films, to study the inhomogeneous distribution of intra-spot binding across 100 micron-diameter protein spots. By measuring intra-spot binding inhomogeneity, reaction kinetics can be determined accurately when combined with a numerical three-dimensional finite element model. To ensure homogeneous binding across a spot, a critical flow rate is identified in terms of the association rate k(a) and the spot diameter. The binding inhomogeneity across a spot can be used to distinguish high-affinity low-concentration specific reactions from low-affinity high-concentration non-specific binding of background proteins.

  18. Rapid mapping of polarization switching through complete information acquisition

    PubMed Central

    Somnath, Suhas; Belianinov, Alex; Kalinin, Sergei V.; Jesse, Stephen

    2016-01-01

    Polarization switching in ferroelectric and multiferroic materials underpins a broad range of current and emergent applications, ranging from random access memories to field-effect transistors, and tunnelling devices. Switching in these materials is exquisitely sensitive to local defects and microstructure on the nanometre scale, necessitating spatially resolved high-resolution studies of these phenomena. Classical piezoresponse force microscopy and spectroscopy, although providing necessary spatial resolution, are fundamentally limited in data acquisition rates and energy resolution. This limitation stems from their two-tiered measurement protocol that combines slow (∼1 s) switching and fast (∼10 kHz–1 MHz) detection waveforms. Here we develop an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias. This approach, facilitated by high-sensitivity electronics and adaptive filtering, enables spectroscopic imaging at a rate 3,504 times faster the current state of the art, achieving high-veracity imaging of polarization dynamics in complex microstructures. PMID:27910941

  19. Diode laser sensor to monitor HCL in a plasma etch reactor

    NASA Astrophysics Data System (ADS)

    Kim, Suhong; Klimecky, Pete; Chou, Shang-I.; Jeffries, Jay B.; Terry, Fred L., Jr.; Hanson, Ronald K.

    2002-09-01

    Absorption measurements of HCl during plasma etching of poly-silicon are made using the P(4) transition in the first vibrational overtone band near 1.79 μm. Single path absorption provides a real-time HCl monitor during etching of six-inch wafers in a commercial Lam Research 9400SE reactor at the University of Michigan. Wavelength modulation at 10.7 MHz is used to distinguish the absorption signal from the strong plasma emission. The laser center frequency is ramp-tuned at 500 Hz providing an HCl measurement every 2ms. Direct absorption measurements without the plasma are used to calibrate the wavelength modulation signal. The minimum detectable absorbance was 5x(10)-6 with 50 ms averaging, leading to an HCl detection limit of ~(10)12cm-3. For a given ratio of the feedstock HBr/Cl2, the measured HCl concentration tracks the average etch rate. These measurements demonstrate the feasibility of a real-time diode laser-based etch rate sensor.

  20. Homogeneous crystal nucleation in Ni droplets

    NASA Astrophysics Data System (ADS)

    Kožíšek, Zdeněk; Demo, Pavel

    2017-10-01

    Crystal nucleation kinetics is often represented by induction times or metastable zone widths (Kulkarni et al., 2013; Bokeloh et al., 2011). Repeating measurements of supercooling or time delay, at which phase transition is detected, are statistically processed to determine the so-called survivorship function, from which nucleation rate is computed. The size distribution of nuclei is difficult to measure near the critical size directly, and it is not clear which amount of nuclei is formed at the moment when the phase transition is detected. In the present paper, kinetic nucleation equations are solved for the crystal nucleation in Ni liquid droplet to determine the number of nuclei formed within a considered system. Analysis of supercooling experimental data, based on the classical nucleation theory CNT), computes appropriate values of the nucleation rate. However, CNT underestimates the number of nuclei F (F ≪ 1 for supercritical sizes). Taking into account the dependence of the surface energy on nucleus size to data analysis overcomes this discrepancy and leads to reasonable values of the size distribution of nuclei.

  1. Comparison of different sampling techniques and of different culture methods for detection of group B streptococcus carriage in pregnant women.

    PubMed

    El Aila, Nabil A; Tency, Inge; Claeys, Geert; Saerens, Bart; Cools, Piet; Verstraelen, Hans; Temmerman, Marleen; Verhelst, Rita; Vaneechoutte, Mario

    2010-09-29

    Streptococcus agalactiae (group B streptococcus; GBS) is a significant cause of perinatal and neonatal infections worldwide. To detect GBS colonization in pregnant women, the CDC recommends isolation of the bacterium from vaginal and anorectal swab samples by growth in a selective enrichment medium, such as Lim broth (Todd-Hewitt broth supplemented with selective antibiotics), followed by subculture on sheep blood agar. However, this procedure may require 48 h to complete. We compared different sampling and culture techniques for the detection of GBS. A total of 300 swabs was taken from 100 pregnant women at 35-37 weeks of gestation. For each subject, one rectovaginal, one vaginal and one rectal ESwab were collected. Plating onto Columbia CNA agar (CNA), group B streptococcus differential agar (GBSDA) (Granada Medium) and chromID Strepto B agar (CA), with and without Lim broth enrichment, were compared. The isolates were confirmed as S. agalactiae using the CAMP test on blood agar and by molecular identification with tDNA-PCR or by 16S rRNA gene sequence determination. The overall GBS colonization rate was 22%. GBS positivity for rectovaginal sampling (100%) was significantly higher than detection on the basis of vaginal sampling (50%), but not significantly higher than for rectal sampling (82%). Direct plating of the rectovaginal swab on CNA, GBSDA and CA resulted in detection of 59, 91 and 95% of the carriers, respectively, whereas subculturing of Lim broth yielded 77, 95 and 100% positivity, respectively. Lim broth enrichment enabled the detection of only one additional GBS positive subject. There was no significant difference between GBSDA and CA, whereas both were more sensitive than CNA. Direct culture onto GBSDA or CA (91 and 95%) detected more carriers than Lim broth enrichment and subculture onto CNA (77%). One false negative isolate was observed on GBSDA, and three false positives on CA. In conclusion, rectovaginal sampling increased the number GBS positive women detected, compared to vaginal and/or rectal sampling. Direct plating on CA and/or GBSDA provided rapid detection of GBS that was at least as sensitive and specific as the CDC recommended method of Lim broth subcultured onto non chromogenic agar.

  2. Multicenter Evaluation of the Cepheid Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Test as a Rapid Screening Method for Detection of MRSA in Nares▿

    PubMed Central

    Wolk, D. M.; Picton, E.; Johnson, D.; Davis, T.; Pancholi, P.; Ginocchio, C. C.; Finegold, S.; Welch, D. F.; de Boer, M.; Fuller, D.; Solomon, M. C.; Rogers, B.; Mehta, M. S.; Peterson, L. R.

    2009-01-01

    The first U.S. multicenter clinical trial to assess the performance of the Cepheid Xpert MRSA assay (Xpert MRSA) was conducted. The assay is a qualitative test designed for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) directly from nares swabs. This novel test combines integrated nucleic acid extraction and automated real-time PCR for the detection of a MRSA-specific signature sequence. A total of 1,077 nares specimens were collected from seven geographically distinct health care sites across the United States with prevalence rates ranging from 5.2% to 44%. Nares specimens were tested by (i) the Xpert MRSA assay, (ii) direct culture on CHROMagar MRSA medium (direct CM culture), and (iii) broth-enriched culture (Trypticase soy broth with 6.5% sodium chloride) followed by plating onto CHROMagar MRSA medium (broth-enriched CM culture). When direct CM culture was designated the reference method, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the Xpert MRSA assay were 94.3%, 93.2%, 73.0%, and 98.8%, respectively. When broth-enriched CM culture was used as the reference method, the clinical sensitivity, specificity, PPV, and NPV of the Xpert MRSA assay were 86.3%, 94.9%, 80.5%, and 96.6%, respectively. The BD GeneOhm MRSA (BDGO) assay was performed as a comparative molecular method. No statistical performance differences were observed between the Xpert MRSA and BDGO assays when they were compared to culture methods. From this large-scale, multicenter clinical comparison, we conclude that the Xpert MRSA assay is a simple, rapid, and accurate method for performing active surveillance for MRSA in a variety of health care populations. PMID:19129414

  3. Towards Routine Uncued Surveillance of Small Objects at and near Geostationary Orbit with Small Telescopes

    NASA Astrophysics Data System (ADS)

    Zimmer, P.; McGraw, J. T.; Ackermann, M. R.

    There is considerable interest in the capability to discover and monitor small objects (d 20cm) in geosynchronous (GEO) and near-GEO orbital regimes using small, ground-based optical telescopes (D < 0.5m). The threat of such objects is clear. Small telescopes have an unrivaled cost advantage and, under ideal lighting and sky conditions, have the capability of detecting faint objects. This combination of conditions, however, is relatively rare, making routine and persistent surveillance more challenging. In a truly geostationary orbit, a small object is easy to detect because its apparent rate of motion is nearly zero for a ground-based observer, and signal accumulation occurs as it would for more traditional sidereal-tracked astronomical observations. In this regime, though, small objects are not expected to be in controlled or predictable orbits, thus a range of inclinations and eccentricities is possible. This results in a range of apparent angular rates and directions that must be surveilled. This firmly establishes this task as uncued or blind surveillance. Detections in this case are subject to what is commonly called “trailing loss,” where the signal from the object does not accumulate in a fixed detection element, resulting in far lower sensitivity than for a similar object optimally tracked. We review some of the limits of detecting these objects under less than ideal observing conditions, subject further to the current limitations based on technological and operational realities. We demonstrate progress towards this goal using telescopes much smaller than normally considered viable for this task using novel detection and analysis techniques.

  4. Disease management: atrial fibrillation and home monitoring.

    PubMed

    Ricci, Renato Pietro

    2013-06-01

    Device-detected atrial fibrillation (AF) episodes predict poor clinical outcome regardless of symptoms. Potential benefits of remote monitoring are early arrhythmia detection and patient continuous monitoring. Several studies of device remote monitoring consistently demonstrated that AF represents the most common clinical alert and that detailed information on arrhythmia onset, duration, and burden as well as on the ventricular rate may be early available for clinical evaluation. Reaction time to AF alerts was very short in all series involving either pacemakers or defibrillators and action ability of AF alerts was very high. In the Home Guide Registry, in which 1650 patients were enrolled, AF was detected in 16.3% of patients and represented 36% of all cardiovascular events during the follow-up. Timely anticoagulation introduction in asymptomatic patients may impact on the stroke rate. According to the results of repeated Monte Carlo simulations based on a real population of 166 patients, daily monitoring may reduce the 2-year stroke risk by 9-18% with an absolute reduction of 0.2-0.6%, compared with conventional inter-visit intervals of 6-12 months. In the COMPAS trial, the incidence of hospitalizations for atrial arrhythmias and related stroke was significantly higher in the control group than in the remote monitoring group. Major questions will be addressed by the ongoing IMPACT trial in which a remote monitoring guided anticoagulation strategy based on AF detection will be compared with a physician-directed standard strategy. In patients with heart failure, AF early detection combined with other indexes may help prevent hospitalizations.

  5. Different deformation patterns using GPS in the volcanic process of El Hierro (Canary Island) 2011-2013

    NASA Astrophysics Data System (ADS)

    García-Cañada, Laura; José García-Arias, María; Pereda de Pablo, Jorge; Lamolda, Héctor; López, Carmen

    2014-05-01

    Ground deformation is one of the most important parameter in volcano monitoring. The detected deformations in volcanic areas can be precursors of a volcanic activity and contribute with useful information to study the evolution of an unrest, eruption or any volcanic process. GPS is the most common technique used to measure volcano deformations. It can be used to detect slow displacement rates or much larger and faster deformations associated with any volcanic process. In volcanoes the deformation is expected to be a mixed of nature; during periods of quiescence it will be slow or not present, while increased activity slow displacement rates can be detected or much larger and faster deformations can be measure due to magma intrusion, for example in the hours to days prior a eruption beginning. In response to the anomalous seismicity detected at El Hierro in July 2011, the Instituto Geográfico Nacional (IGN) improved its volcano monitoring network in the island with continuous GPS that had been used to measure the ground deformation associated with the precursory unrest since summer 2011, submarine eruption (October 2011-March 2012) and the following unrest periods (2012-2013). The continuous GPS time series, together with other techniques, had been used to evaluate the activity and to detect changes in the process. We investigate changes in the direction and module of the deformation obtained by GPS and they show different patterns in every unrest period, very close to the seismicity locations and migrations.

  6. Detectable Seismic Consequences of the Interaction of a Primordial Black Hole with Earth

    NASA Astrophysics Data System (ADS)

    Luo, Yang; Hanasoge, Shravan; Tromp, Jeroen; Pretorius, Frans

    2012-05-01

    Galaxies observed today are likely to have evolved from density perturbations in the early universe. Perturbations that exceeded some critical threshold are conjectured to have undergone gravitational collapse to form primordial black holes (PBHs) at a range of masses. Such PBHs serve as candidates for cold dark matter, and their detection would shed light on conditions in the early universe. Here, we propose a mechanism to search for transits of PBHs through/nearby Earth by studying the associated seismic waves. Using a spectral-element method, we simulate and visualize this seismic wave field in Earth's interior. We predict the emergence of two unique signatures, namely, a wave that would arrive almost simultaneously everywhere on Earth's free surface and the excitation of unusual spheroidal modes with a characteristic frequency spacing in free oscillation spectra. These qualitative characteristics are unaffected by the speed or proximity of the PBH trajectory. The seismic energy deposited by a proximal M PBH = 1015 g PBH is comparable to a magnitude M w = 4 earthquake. The non-seismic collateral damage due to the actual impact of such small PBHs with Earth would be negligible. Unfortunately, the expected collision rate is very low even if PBHs constituted all of dark matter, at ~10-7 yr-1, and since the rate scales as 1/M PBH, fortunately encounters with larger, Earth-threatening PBHs are exceedingly unlikely. However, the rate at which non-colliding close encounters of PBHs could be detected by seismic activity alone is roughly two orders of magnitude larger—that is once every hundred thousand years—than the direct collision rate.

  7. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging.

    PubMed

    Daryaei, Iman; Pagel, Mark D

    2015-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T 2 -exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T 1 and T 2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging.

  8. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging

    PubMed Central

    Daryaei, Iman; Pagel, Mark D

    2016-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a “double-agent” approach to molecular imaging. Exogenous T2-exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T1 and T2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as “secret agents” in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging. PMID:27747191

  9. Comparison of clinical performances among Roche Cobas HPV, RFMP HPV PapilloTyper and Hybrid Capture 2 assays for detection of high-risk types of human papillomavirus.

    PubMed

    Yu, Shinae; Kwon, Min-Jung; Lee, Eun Hee; Park, Hyosoon; Woo, Hee-Yeon

    2015-09-01

    The cervical cancer screening guidelines suggest that early detection of HPV16 and HPV18 is helpful for identifying women with cervical intraepithelial neoplasia (CIN) grade two or higher. We comparatively evaluated three HPV DNA assays, Roche Cobas HPV, RFMP HPV PapilloTyper, and Hybrid Capture 2 (HC2). A total of 861 cervical swab samples from women over 30 years of age were classified into two groups, that is, high grade squamous intraepithelial lesion (HSIL) and non-HSIL, according to cervical cytology results and analyzed by three assays. The results of direct sequencing or Linear array HPV genotyping test were considered true when the three assays presented discrepancies. The concordance rates between Roche Cobas HPV versus RFMP HPV PapilloTyper, RFMP HPV PapilloTyper versus HC2, and Roche Cobas versus HC2 were 94.5%, 94.3%, and 95.9%, respectively. For detection of HPV16 and HPV18, Roche Cobas HPV showed the concordance rates of 98.3% (κ = 0.73) and 99.4% (κ = 0.40) with the confirmation tests, respectively; and RFMP HPV PapilloTyper showed the concordance rates of 99.5% (κ = 0.92) and 100.0% (κ = 1.00), respectively. In conclusion, Roche Cobas HPV, RFMP HPV PapilloTyper, and HC2 showed high agreement rates. Roche Cobas HPV and RFMP HPV PapilloTyper are particularly useful, since both provide HPV specific genotypes, HPV16 and HPV18. © 2015 Wiley Periodicals, Inc.

  10. Real-time detection system for tumor localization during minimally invasive surgery for gastric and colon cancer removal: In vivo feasibility study in a swine model.

    PubMed

    Choi, Won Jung; Moon, Jin-Hee; Min, Jae Seok; Song, Yong Keun; Lee, Seung A; Ahn, Jin Woo; Lee, Sang Hun; Jung, Ha Chul

    2018-03-01

    During minimally invasive surgery (MIS), it is impossible to directly detect marked clips around tumors via palpation. Therefore, we developed a novel method and device using Radio Frequency IDentification (RFID) technology to detect the position of clips during minimally invasive gastrectomy or colectomy. The feasibility of the RFID-based detection system was evaluated in an animal experiment consisting of seven swine. The primary outcome was to successfully detect the location of RFID clips in the stomach and colon. The secondary outcome measures were to detect time (time during the intracorporeal detection of the RFID clip), and accuracy (distance between the RFID clip and the detected site). A total of 25 detection attempts (14 in the stomach and 11 in the colon) using the RFID antenna had a 100% success rate. The median detection time was 32.5 s (range, 15-119 s) for the stomach and 28.0 s (range, 8-87 s) for the colon. The median detection distance was 6.5 mm (range, 4-18 mm) for the stomach and 6.0 mm (range, 3-13 mm) for the colon. We demonstrated favorable results for a RFID system that detects the position of gastric and colon tumors in real-time during MIS. © 2017 Wiley Periodicals, Inc.

  11. Parametric Amplification For Detecting Weak Optical Signals

    NASA Technical Reports Server (NTRS)

    Hemmati, Hamid; Chen, Chien; Chakravarthi, Prakash

    1996-01-01

    Optical-communication receivers of proposed type implement high-sensitivity scheme of optical parametric amplification followed by direct detection for reception of extremely weak signals. Incorporates both optical parametric amplification and direct detection into optimized design enhancing effective signal-to-noise ratios during reception in photon-starved (photon-counting) regime. Eliminates need for complexity of heterodyne detection scheme and partly overcomes limitations imposed on older direct-detection schemes by noise generated in receivers and by limits on quantum efficiencies of photodetectors.

  12. Digital TV processing system

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Two digital video data compression systems directly applicable to the Space Shuttle TV Communication System were described: (1) For the uplink, a low rate monochrome data compressor is used. The compression is achieved by using a motion detection technique in the Hadamard domain. To transform the variable source rate into a fixed rate, an adaptive rate buffer is provided. (2) For the downlink, a color data compressor is considered. The compression is achieved first by intra-color transformation of the original signal vector, into a vector which has lower information entropy. Then two-dimensional data compression techniques are applied to the Hadamard transformed components of this last vector. Mathematical models and data reliability analyses were also provided for the above video data compression techniques transmitted over a channel encoded Gaussian channel. It was shown that substantial gains can be achieved by the combination of video source and channel coding.

  13. Estimating site occupancy, colonization, and local extinction when a species is detected imperfectly

    USGS Publications Warehouse

    MacKenzie, D.I.; Nichols, J.D.; Hines, J.E.; Knutson, M.G.; Franklin, A.B.

    2003-01-01

    Few species are likely to be so evident that they will always be detected when present. Failing to allow for the possibility that a target species was present, but undetected, at a site will lead to biased estimates of site occupancy, colonization, and local extinction probabilities. These population vital rates are often of interest in long-term monitoring programs and metapopulation studies. We present a model that enables direct estimation of these parameters when the probability of detecting the species is less than 1. The model does not require any assumptions of process stationarity, as do some previous methods, but does require detection/nondetection data to be collected in a manner similar to Pollock's robust design as used in mark?recapture studies. Via simulation, we show that the model provides good estimates of parameters for most scenarios considered. We illustrate the method with data from monitoring programs of Northern Spotted Owls (Strix occidentalis caurina) in northern California and tiger salamanders (Ambystoma tigrinum) in Minnesota, USA.

  14. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    PubMed Central

    Mochizuki, Yohei; Yoshimatsu, Hiroki; Niina, Ayaka; Teshima, Takahiro; Matsumoto, Hirotaka; Koyama, Hidekazu

    2018-01-01

    Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI). The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous. PMID:29449957

  15. Detection of M. tuberculosis using DNA chips combined with an image analysis system.

    PubMed

    Huang, T-S; Liu, Y-C; Bair, C-H; Sy, C-L; Chen, Y-S; Tu, H-Z; Chen, B-C

    2008-01-01

    To develop a packaged DNA chip assay (the DR. MTBC Screen assay) for direct detection of the Mycobacterium tuberculosis complex. We described a DNA chip assay based on the IS6110 gene that can be used for the detection of M. tuberculosis complex. Probes were spotted onto the polystyrene strips in the wells of 96-well microtitre plates and used for hybridisation with biotin-labelled amplicon to yield a pattern of visualised positive spots. The plate image was scanned, analysed and interpreted automatically. The results corresponded well with those obtained by conventional culture as well as clinical diagnosis, with sensitivity and specificity rates of respectively 83.8% and 94.2%, and 84.6% and 96.3%. We conclude that the DR. MTBC Screen assay can detect M. tuberculosis complex rapidly in respiratory specimens, readily adapts to routine work and provides a flexible choice to meet different cost-effectiveness and automation needs in TB-endemic countries. The cost for reagents is around US$10 per sample.

  16. System considerations for detection and tracking of small targets using passive sensors

    NASA Astrophysics Data System (ADS)

    DeBell, David A.

    1991-08-01

    Passive sensors provide only a few discriminants to assist in threat assessment of small targets. Tracking of the small targets provides additional discriminants. This paper discusses the system considerations for tracking small targets using passive sensors, in particular EO sensors. Tracking helps establish good versus bad detections. Discussed are the requirements to be placed on the sensor system's accuracy, with respect to knowledge of the sightline direction. The detection of weak targets sets a requirement for two levels of tracking in order to reduce processor throughput. A system characteristic is the need to track all detections. For low thresholds, this can mean a heavy track burden. Therefore, thresholds must be adaptive in order not to saturate the processors. Second-level tracks must develop a range estimate in order to assess threat. Sensor platform maneuvers are required if the targets are moving. The need for accurate pointing, good stability, and a good update rate will be shown quantitatively, relating to track accuracy and track association.

  17. Plasmonic nanosensors with inverse sensitivity by means of enzyme-guided crystal growth

    NASA Astrophysics Data System (ADS)

    Rodríguez-Lorenzo, Laura; de La Rica, Roberto; Álvarez-Puebla, Ramón A.; Liz-Marzán, Luis M.; Stevens, Molly M.

    2012-07-01

    Lowering the limit of detection is key to the design of sensors needed for food safety regulations, environmental policies and the diagnosis of severe diseases. However, because conventional transducers generate a signal that is directly proportional to the concentration of the target molecule, ultralow concentrations of the molecule result in variations in the physical properties of the sensor that are tiny, and therefore difficult to detect with confidence. Here we present a signal-generation mechanism that redefines the limit of detection of nanoparticle sensors by inducing a signal that is larger when the target molecule is less concentrated. The key step to achieve this inverse sensitivity is to use an enzyme that controls the rate of nucleation of silver nanocrystals on plasmonic transducers. We demonstrate the outstanding sensitivity and robustness of this approach by detecting the cancer biomarker prostate-specific antigen down to 10-18 g ml-1 (4 × 10-20 M) in whole serum.

  18. A Smart Spoofing Face Detector by Display Features Analysis.

    PubMed

    Lai, ChinLun; Tai, ChiuYuan

    2016-07-21

    In this paper, a smart face liveness detector is proposed to prevent the biometric system from being "deceived" by the video or picture of a valid user that the counterfeiter took with a high definition handheld device (e.g., iPad with retina display). By analyzing the characteristics of the display platform and using an expert decision-making core, we can effectively detect whether a spoofing action comes from a fake face displayed in the high definition display by verifying the chromaticity regions in the captured face. That is, a live or spoof face can be distinguished precisely by the designed optical image sensor. To sum up, by the proposed method/system, a normal optical image sensor can be upgraded to a powerful version to detect the spoofing actions. The experimental results prove that the proposed detection system can achieve very high detection rate compared to the existing methods and thus be practical to implement directly in the authentication systems.

  19. Effects of Agronomic Treatments on Structure and Function of Ammonia-Oxidizing Communities

    PubMed Central

    Phillips, Carol J.; Harris, Dave; Dollhopf, Sherry L.; Gross, Katherine L.; Prosser, James I.; Paul, Eldor A.

    2000-01-01

    The aim of this study was to determine the effects of different agricultural treatments and plant communities on the diversity of ammonia oxidizer populations in soil. Denaturing gradient gel electrophoresis (DGGE), coupled with specific oligonucleotide probing, was used to analyze 16S rRNA genes of ammonia oxidizers belonging to the β subgroup of the division Proteobacteria by use of DNA extracted from cultivated, successional, and native deciduous forest soils. Community profiles of the different soil types were compared with nitrification rates and most-probable-number (MPN) counts. Despite significant variation in measured nitrification rates among communities, there were no differences in the DGGE banding profiles of DNAs extracted from these soils. DGGE profiles of DNA extracted from samples of MPN incubations, cultivated at a range of ammonia concentrations, showed the presence of bands not amplified from directly extracted DNA. Nitrosomonas-like bands were seen in the MPN DNA but were not detected in the DNA extracted directly from soils. These bands were detected in some samples taken from MPN incubations carried out with medium containing 1,000 μg of NH4+-N ml−1, to the exclusion of bands detected in the native DNA. Cell concentrations of ammonia oxidizers determined by MPN counts were between 10- and 100-fold lower than those determined by competitive PCR (cPCR). Although no differences were seen in ammonia oxidizer MPN counts from the different soil treatments, cPCR revealed higher numbers in fertilized soils. The use of a combination of traditional and molecular methods to investigate the activities and compositions of ammonia oxidizers in soil demonstrates differences in fine-scale compositions among treatments that may be associated with changes in population size and function. PMID:11097922

  20. In vivo 13C MRS in the mouse brain at 14.1 Tesla and metabolic flux quantification under infusion of [1,6-13C2]glucose.

    PubMed

    Lai, Marta; Lanz, Bernard; Poitry-Yamate, Carole; Romero, Jackeline F; Berset, Corina M; Cudalbu, Cristina; Gruetter, Rolf

    2017-01-01

    In vivo 13 C magnetic resonance spectroscopy (MRS) enables the investigation of cerebral metabolic compartmentation while, e.g. infusing 13 C-labeled glucose. Metabolic flux analysis of 13 C turnover previously yielded quantitative information of glutamate and glutamine metabolism in humans and rats, while the application to in vivo mouse brain remains exceedingly challenging. In the present study, 13 C direct detection at 14.1 T provided highly resolved in vivo spectra of the mouse brain while infusing [1,6- 13 C 2 ]glucose for up to 5 h. 13 C incorporation to glutamate and glutamine C4, C3, and C2 and aspartate C3 were detected dynamically and fitted to a two-compartment model: flux estimation of neuron-glial metabolism included tricarboxylic acid cycle (TCA) flux in astrocytes (V g  = 0.16 ± 0.03 µmol/g/min) and neurons (V TCA n  = 0.56 ± 0.03 µmol/g/min), pyruvate carboxylase activity (V PC  = 0.041 ± 0.003 µmol/g/min) and neurotransmission rate (V NT  = 0.084 ± 0.008 µmol/g/min), resulting in a cerebral metabolic rate of glucose (CMR glc ) of 0.38 ± 0.02 µmol/g/min, in excellent agreement with that determined with concomitant 18 F-fluorodeoxyglucose positron emission tomography ( 18 FDG PET).We conclude that modeling of neuron-glial metabolism in vivo is accessible in the mouse brain from 13 C direct detection with an unprecedented spatial resolution under [1,6- 13 C 2 ]glucose infusion.

Top