Frasure, Jamey
2008-01-01
This paper is a report of a systematic review describing instruments used to measure nurses' attitudes towards research utilization. Researchers need to have the tools to measure nurses' attitudes. However, limited literature critically analyses instruments and the concepts that comprise nurses' attitudes towards research utilization. A search of the literature from 1982 to 2007 was performed using the Cumulative Index to Nursing and Allied Health Literature, Health and Psychosocial Instruments, PubMed and MEDLINE data bases. The search terms were nursing research, research utilization, instruments, and nurses' attitudes. A total of 186 sources were identified, of which 25 were reviewed. Fourteen instruments met the criteria for in-depth critical analysis of psychometric properties and concepts, and were included in the final review. Each instrument item was judged to be relevant to direct, indirect, persuasive and overall research utilization as defined by Estabrooks. Instruments were arranged from the strongest to the weakest reliability of the subscales to determine the instrument with the strongest psychometric properties. Indirect and overall research utilization was measured by all of the instruments. Ten instruments measured direct research utilization and nine instruments measured persuasive research utilization. The Research Utilization in Nursing Survey by Estabrooks, as adapted by Kenny, was an instrument with strong psychometric properties measuring all four concepts of nurses' attitudes towards using and participating in research and was clinically feasible. Many published instruments are available for use by nurse researchers to measure nurses' attitude towards research utilization, but only one has been subjected to rigorous testing: the Research Utilization in Nursing Survey by Estabrooks.
14 CFR 23.1303 - Flight and navigation instruments.
Code of Federal Regulations, 2013 CFR
2013-01-01
... navigation instruments: (a) An airspeed indicator. (b) An altimeter. (c) A magnetic direction indicator. (d... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flight and navigation instruments. 23.1303... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment...
The 1981 direct strike lightning data. [utilizing the F-106 aircraft
NASA Technical Reports Server (NTRS)
Pitts, F. L.; Thomas, M. E.
1982-01-01
Data waveforms obtained during the 1981 direct strike lightning tests, utilizing the NASA F-106B aircraft specially instrumented for lightning electromagnetic measurements are presented. The aircraft was operated in a thunderstorm environment to elicit strikes. Electromagnetic field data were recorded for both attached lightning and free field excitation of the aircraft.
Insurance and the utilization of medical services.
Meer, Jonathan; Rosen, Harvey S
2004-05-01
Most data sets indicate a positive correlation between having health insurance and utilizing health care services. Yet the direction of causality is not at all clear. If we observe a positive correlation between the utilization of health care services and insurance status, we do not know if this is because people who anticipate poor health buy more insurance (or take jobs with generous medical coverage), or because insurance lowers the cost of health care, increasing the quantity demanded. While a few attempts have been made to implement an instrumental variables (IV) strategy to deal with endogeneity, the instruments chosen have not been entirely convincing. In this paper we revisit the IV estimation of the reduced form relationships between insurance and health care utilization taking advantage of what we argue is a good instrument-the individual's self-employment status. Our main finding is that a positive and statistically significant effect of insurance continues to obtain even after instrumenting. Indeed, instrumental variables estimates of the impact of insurance on utilization of a variety of health care services are larger than their non-instrumented counterparts. The validity of this exercise depends on the extent to which self-employment status is a suitable instrument. To argue this case, we analyze panel data on transitions from wage-earning into self-employment and show that individuals who select into self-employment do not differ systematically from those who remain wage-earners with respect to either the utilization of health care or health status. While this finding does not prove that self-employment status is an appropriate instrument, it is encouraging that there appear to be no underlying differences that might lead to self-employment per se affecting health services utilization.
Anthro-Centric Multisensory Interfaces for Sensory Augmentation of Telesurgery
2011-06-01
compares favorably to standing astride an operating table using laparoscopic instruments, the most favorable ergonomics would facilitate free movement...either through direct contact with the tissues or indirect contact via rigid laparoscopic instruments), opportunities now exist to utilize other...tele-surgical methods. Laparoscopic instruments were initially developed as extended versions of their counterparts used in open procedures (e.g
Robotic right middle lobectomy with a subxiphoid utility port.
Jayakumar, Shruti; Nardini, Marco; Papoulidis, Pavlos; Dunning, Joel
2018-06-01
We present the case of a 74-year-old man with Stage IIa pulmonary adenocarcinoma, for which he underwent a robotic right middle lobectomy. A 4-armed, 5-port approach was used. Four intercostal ports were created above the ninth rib using the Cerfolio's technique. The subxiphoid port was created in the midline, 5 cm down from the xiphisternum. The robot offers higher image quality, depth perception and improved articulation of the instruments, allowing for more accurate dissection and stitching. The usage of a subxiphoid utility port reduces the clashing between instruments, offers a good angle for stapling and provides a direct view of the instruments entering into the chest. Specimen removal through the subxiphoid port may reduce postoperative pain and enhance patient recovery. The use of the subxiphoid approach as a utility port for robotic surgery is promising and may be a suitable replacement for the traditional utility port.
The three principles of action: a Pavlovian-instrumental transfer hypothesis
Cartoni, Emilio; Puglisi-Allegra, Stefano; Baldassarre, Gianluca
2013-01-01
Pavlovian conditioned stimuli can influence instrumental responding, an effect called Pavlovian-instrumental transfer (PIT). During the last decade, PIT has been subdivided into two types: specific PIT and general PIT, each having its own neural substrates. Specific PIT happens when a conditioned stimulus (CS) associated with a reward enhances an instrumental response directed to the same reward. Under general PIT, instead, the CS enhances a response directed to a different reward. While important progress has been made into identifying the neural substrates, the function of specific and general PIT and how they interact with instrumental responses are still not clear. In the experimental paradigm that distinguishes specific and general PIT an effect of PIT inhibition has also been observed and is waiting for an explanation. Here we propose an hypothesis that links these three PIT effects (specific PIT, general PIT and PIT inhibition) to three aspects of action evaluation. These three aspects, which we call “principles of action”, are: context, efficacy, and utility. In goal-directed behavior, an agent has to evaluate if the context is suitable to accomplish the goal, the efficacy of his action in getting the goal, and the utility of the goal itself: we suggest that each of the three PIT effects is related to one of these aspects of action evaluation. In particular, we link specific PIT with the estimation of efficacy, general PIT with the evaluation of utility, and PIT inhibition with the adequacy of context. We also provide a latent cause Bayesian computational model that exemplifies this hypothesis. This hypothesis and the model provide a new framework and new predictions to advance knowledge about PIT functioning and its role in animal adaptation. PMID:24312025
ERIC Educational Resources Information Center
Young, John Q.; Lieu, Sandra; O'Sullivan, Patricia; Tong, Lowell
2011-01-01
Objective: The authors developed and tested the feasibility and utility of a new direct-observation instrument to assess trainee performance of a medication management session. Methods: The Psychopharmacotherapy-Structured Clinical Observation (P-SCO) instrument was developed based on multiple sources of expertise and then implemented in 4…
Data acquisition instruments: Psychopharmacology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartley, D.S. III
This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended.more » In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.« less
Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers
NASA Technical Reports Server (NTRS)
Piepmeier, Jeffrey R.; Shah, Rashmi; Deshpande, Manohar; Johnson, Carey
2014-01-01
Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.
An overview of instrumentation for the Large Binocular Telescope
NASA Astrophysics Data System (ADS)
Wagner, R. Mark
2012-09-01
An overview of instrumentation for the Large Binocular Telescope (LBT) is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' x 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the left and right direct F/15 Gregorian foci incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 2000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCI), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at the left and right front bent F/15 Gregorian foci and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multiobject spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 × 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development that can utilize the full 23-m baseline of the LBT include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). LBTI is currently undergoing commissioning on the LBT and utilizing the installed adaptive secondary mirrors in both single- sided and two-sided beam combination modes. In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. Over the past four years the LBC pair, LUCI1, and MODS1 have been commissioned and are now scheduled for routine partner science observations. The delivery of both LUCI2 and MODS2 is anticipated before the end of 2012. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.
Collado-Mateo, Daniel; Chen, Gang; Garcia-Gordillo, Miguel A; Iezzi, Angelo; Adsuar, José C; Olivares, Pedro R; Gusi, Narcis
2017-05-30
The revised version of the Fibromyalgia Impact Questionnaire (FIQR) is one of the most widely used specific questionnaires in FM studies. However, this questionnaire does not allow calculation of QALYs as it is not a preference-based measure. The aim of this study was to develop mapping algorithm which enable FIQR scores to be transformed into utility scores that can be used in the cost utility analyses. A cross-sectional survey was conducted. One hundred and 92 Spanish women with Fibromyalgia were asked to complete four general quality of life questionnaires, i.e. EQ-5D-5 L, 15D, AQoL-8D and SF-12, and one specific disease instrument, the FIQR. A direct mapping approach was adopted to derive mapping algorithms between the FIQR and each of the four multi-attribute utility (MAU) instruments. Health state utility was treated as the dependent variable in the regression analysis, whilst the FIQR score and age were predictors. The mean utility scores ranged from 0.47 (AQoL-8D) to 0.69 (15D). All correlations between the FIQR total score and MAU instruments utility scores were highly significant (p < 0.0001) with magnitudes larger than 0.5. Although very slight differences in the mean absolute error were found between ordinary least squares (OLS) estimator and generalized linear model (GLM), models based on GLM were better for EQ-5D-5 L, AQoL-8D and 15D. Mapping algorithms developed in this study enable the estimation of utility values from scores in a fibromyalgia specific questionnaire.
Momentum rate probe for use with two-phase flows
NASA Astrophysics Data System (ADS)
Bush, S. G.; Bennett, J. B.; Sojka, P. E.; Panchagnula, M. V.; Plesniak, M. W.
1996-05-01
An instrument for measuring the momentum rate of two-phase flows is described, and design and construction details are provided. The device utilizes a conelike body to turn the flow from the axial to the radial direction. The force resulting from the change in momentum rate of the turning flow is measured using a strain-gage-instrumented cantilevered beam. The instrument is applicable to a wide range of flows including nuclear reactor coolant streams, refrigerants in heating-ventilating air-conditioning equipment, impingement cooling of small scale electronic hardware (computer chips are one example), supercritical fuel injection (in Diesel engines, for instance), and consumer product sprays (such as hair-care product sprays produced using effervescent atomizers). The latter application is discussed here. Features of the instrument include sensitivity to a wide range of forces and the ability to damp oscillations of the deflection cone. Instrument sensitivity allows measurement of momentum rates considerably lower (below 0.01 N) than those that could be obtained using previous devices. This feature is a direct result of our use of precision strain gages, capable of sensing strains below 20 μm/m, and the damping of oscillations which can overwhelm the force measurements. Oscillation damping results from a viscous fluid damper whose resistance is easily varied by changing fluids. Data used to calibrate the instrument are presented to demonstrate the effectiveness of the technique. As an example of the instrument's utility, momentum rate data obtained using it will be valuable in efforts to explain entrainment of surrounding air into effervescent atomizer-produced sprays and also to model the effervescent atomization process.
Direct Behavior Rating Instrumentation: Evaluating the Impact of Scale Formats
ERIC Educational Resources Information Center
Miller, Faith G.; Riley-Tillman, T. Chris; Chafouleas, Sandra M.; Schardt, Alyssa A.
2017-01-01
The purpose of this study was to investigate the impact of two different Direct Behavior Rating--Single Item Scale (DBR-SIS) formats on rating accuracy. A total of 119 undergraduate students participated in one of two study conditions, each utilizing a different DBR-SIS scale format: one that included percentage of time anchors on the DBR-SIS…
Converting Parkinson-Specific Scores into Health State Utilities to Assess Cost-Utility Analysis.
Chen, Gang; Garcia-Gordillo, Miguel A; Collado-Mateo, Daniel; Del Pozo-Cruz, Borja; Adsuar, José C; Cordero-Ferrera, José Manuel; Abellán-Perpiñán, José María; Sánchez-Martínez, Fernando Ignacio
2018-06-07
The aim of this study was to compare the Parkinson's Disease Questionnaire-8 (PDQ-8) with three multi-attribute utility (MAU) instruments (EQ-5D-3L, EQ-5D-5L, and 15D) and to develop mapping algorithms that could be used to transform PDQ-8 scores into MAU scores. A cross-sectional study was conducted. A final sample of 228 evaluable patients was included in the analyses. Sociodemographic and clinical data were also collected. Two EQ-5D questionnaires were scored using Spanish tariffs. Two models and three statistical techniques were used to estimate each model in the direct mapping framework for all three MAU instruments, including the most widely used ordinary least squares (OLS), the robust MM-estimator, and the generalized linear model (GLM). For both EQ-5D-3L and EQ-5D-5L, indirect response mapping based on an ordered logit model was also conducted. Three goodness-of-fit tests were employed to compare the models: the mean absolute error (MAE), the root-mean-square error (RMSE), and the intra-class correlation coefficient (ICC) between the predicted and observed utilities. Health state utility scores ranged from 0.61 (EQ-5D-3L) to 0.74 (15D). The mean PDQ-8 score was 27.51. The correlation between overall PDQ-8 score and each MAU instrument ranged from - 0.729 (EQ-5D-5L) to - 0.752 (EQ-5D-3L). A mapping algorithm based on PDQ-8 items had better performance than using the overall score. For the two EQ-5D questionnaires, in general, the indirect mapping approach had comparable or even better performance than direct mapping based on MAE. Mapping algorithms developed in this study enable the estimation of utility values from the PDQ-8. The indirect mapping equations reported for two EQ-5D questionnaires will further facilitate the calculation of EQ-5D utility scores using other country-specific tariffs.
Validation of Reverse-Engineered and Additive-Manufactured Microsurgical Instrument Prototype.
Singh, Ramandeep; Suri, Ashish; Anand, Sneh; Baby, Britty
2016-12-01
With advancements in imaging techniques, neurosurgical procedures are becoming highly precise and minimally invasive, thus demanding development of new ergonomically aesthetic instruments. Conventionally, neurosurgical instruments are manufactured using subtractive manufacturing methods. Such a process is complex, time-consuming, and impractical for prototype development and validation of new designs. Therefore, an alternative design process has been used utilizing blue light scanning, computer-aided designing, and additive manufacturing direct metal laser sintering (DMLS) for microsurgical instrument prototype development. Deviations of DMLS-fabricated instrument were studied by superimposing scan data of fabricated instrument with the computer-aided designing model. Content and concurrent validity of the fabricated prototypes was done by a group of 15 neurosurgeons by performing sciatic nerve anastomosis in small laboratory animals. Comparative scoring was obtained for the control and study instrument. T test was applied to the individual parameters and P values for force (P < .0001) and surface roughness (P < .01) were found to be statistically significant. These 2 parameters were further analyzed using objective measures. Results depicts that additive manufacturing by DMLS provides an effective method for prototype development. However, direct application of these additive-manufactured instruments in the operating room requires further validation. © The Author(s) 2016.
Education-related inequity in healthcare with heterogeneous reporting of health
d’Uva, Teresa Bago; Lindeboom, Maarten; O’Donnell, Owen; van Doorslaer, Eddy
2011-01-01
Summary Reliance on self-rated health to proxy medical need can bias estimation of education-related inequity in healthcare utilization. We correct this bias both by instrumenting self-rated health with objective health indicators and by purging self-rated health of reporting heterogeneity that is identified from health vignettes. Using data on elderly Europeans, we find that instrumenting self-rated health shifts the distribution of visits to a doctor in the direction of inequality favouring the better educated. There is a further, and typically larger, shift in the same direction when correction is made for the tendency of the better educated to rate their health more negatively. PMID:21938140
Estimating QALY gains in applied studies: a review of cost-utility analyses published in 2010.
Wisløff, Torbjørn; Hagen, Gunhild; Hamidi, Vida; Movik, Espen; Klemp, Marianne; Olsen, Jan Abel
2014-04-01
Reimbursement agencies in several countries now require health outcomes to be measured in terms of quality-adjusted life-years (QALYs), leading to an immense increase in publications reporting QALY gains. However, there is a growing concern that the various 'multi-attribute utility' (MAU) instruments designed to measure the Q in the QALY yield disparate values, implying that results from different instruments are incommensurable. By reviewing cost-utility analyses published in 2010, we aim to contribute to improved knowledge on how QALYs are currently calculated in applied analyses; how transparently QALY measurement is presented; and how large the expected incremental QALY gains are. We searched Embase, MEDLINE and NHS EED for all cost-utility analyses published in 2010. All analyses that had estimated QALYs gained from health interventions were included. Of the 370 studies included in this review, 48% were pharmacoeconomic evaluations. Active comparators were used in 71% of studies. The median incremental QALY gain was 0.06, which translates to 3 weeks in best imaginable health. The EQ-5D-3L is the dominant instrument used. However, reporting of how QALY gains are estimated is generally inadequate. In 55% of the studies there was no reference to which MAU instrument or direct valuation method QALY data came from. The methods used for estimating expected QALY gains are not transparently reported in published papers. Given the wide variation in utility scores that different methodologies may assign to an identical health state, it is important for journal editors to require a more transparent way of reporting the estimation of incremental QALY gains.
Child temperament, parent affect, and feeding in normal and overweight preschool children
USDA-ARS?s Scientific Manuscript database
Despite overwhelming evidence showing that parent emotional affect impacts parenting directives and child outcomes, little research has focused on the influence of parent affect on feeding as a mechanism in shaping children's eating patterns. Utilizing an instrument characterizing parent strategies ...
Effectiveness of Miles-Per-Gallon Meters as a Means to Conserve Gasoline in Automobiles
DOT National Transportation Integrated Search
1976-10-01
This report is an assessment of fuel flow instruments reading directly in miles per gallon (mpg). It describes currently available mpg meters, their installation, utility, and safety and presents an analysis of potential cost savings. It discusses me...
Burden of disease of reoperations in instrumental spinal surgeries in Germany.
Jacob, Christian; Annoni, Elena; Haas, Jennifer Scarlet; Braun, Sebastian; Winking, Michael; Franke, Jörg
2016-03-01
To estimate the incidence of instrumental spinal surgeries (ISS) and consecutive reoperations and to calculate the related resource utilization and costs. ISS and subsequent reoperations were identified retrospectively using surgery codes in claims data. The study period included January 01, 2009 to December 31, 2011. The reoperation rate was calculated for 1 year after the primary ISS. Resource utilization and costs were analyzed by group comparison. A total of 3316 incident ISS patients were identified in 2010 with an annual reoperation rate of 9.98% (95% CI 8.98-11.02%). Mean costs per patient were €11,331 per ISS and €11,370 per reoperation, with €8432 directly attributed to the reoperation and €2938 to additional resources. Costs of ISS and subsequent reoperations have a significant impact on health insurances budgets. The annual cost of reoperations exceeds the direct cost of the primary surgery driven by the need for further inpatient and outpatient care.
Gamst-Klaussen, Thor; Chen, Gang; Lamu, Admassu N; Olsen, Jan Abel
2016-07-01
Different health state utility (HSU) instruments produce different utilities for the same individuals, thereby compromising the intended comparability of economic evaluations of health care interventions. When developing crosswalks, previous studies have indicated nonlinear relationships. This paper inquires into the degree of nonlinearity across the four most widely used HSU-instruments and proposes exchange rates that differ depending on the severity levels of the health state utility scale. Overall, 7933 respondents from six countries, 1760 in a non-diagnosed healthy group and 6173 in seven disease groups, reported their health states using four different instruments: EQ-5D-5L, SF-6D, HUI-3 and 15D. Quantile regressions investigate the degree of nonlinear relationships between these instruments. To compare the instruments across different disease severities, we split the health state utility scale into utility intervals with 0.2 successive decrements in utility starting from perfect health at 1.00. Exchange rates (ERs) are calculated as the mean utility difference between two utility intervals on one HSU-instrument divided by the difference in mean utility on another HSU-instrument. Quantile regressions reveal significant nonlinear relationships across all four HSU-instruments. The degrees of nonlinearities differ, with a maximum degree of difference in the coefficients along the health state utility scale of 3.34 when SF-6D is regressed on EQ-5D. At the lower end of the health state utility scale, the exchange rate from SF-6D to EQ-5D is 2.11, whilst at the upper end it is 0.38. Comparisons at different utility levels illustrate the fallacy of using linear functions as crosswalks between HSU-instruments. The existence of nonlinear relationships between different HSU-instruments suggests that level-specific exchange rates should be used when converting a change in utility on the instrument used, onto a corresponding utility change had another instrument been used. Accounting for nonlinearities will increase the validity of the comparison for decision makers when faced with a choice between interventions whose calculations of QALY gains have been based on different HSU-instruments.
Evaluation, Instruction and Policy Making. IIEP Seminar Paper: 9.
ERIC Educational Resources Information Center
Bloom, Benjamin S.
Recently, educational evaluation has attempted to use the precision, objectivity, and mathematical rigor of the psychological measurement field as well as to find ways in which instrumentation and data utilization could more directly be related to educational institutions, educational processes, and educational purposes. The linkages between…
Utilization of Marketing Techniques in California Community Colleges.
ERIC Educational Resources Information Center
Gregory, Judi A.
A survey of the 107 California community colleges was conducted during Spring 1980 to assess the extent to which college administrators had adopted marketing techniques. The survey instrument listed 31 such techniques under six general categories: marketing surveys, direct advertising, public information, high school recruiting, community…
NASA Technical Reports Server (NTRS)
Johnson, Jerome B.; Boynton, William V.; Davis, Keil; Elphic, Richard; Glass, Brian; Haldemann, Albert F. C.; Adams, Frederick W.
2005-01-01
The Construction Resource Utilization Explorer (CRUX) is a technology maturation project for the U.S. National Aeronautics and Space Administration to provide enabling technology for lunar and planetary surface operations (LPSO). The CRUX will have 10 instruments, a data handling function (Mapper - with features of data subscription, fusion, interpretation, and publication through geographical information system [GIs] displays), and a decision support system DSS) to provide information needed to plan and conduct LPSO. Six CRUX instruments are associated with an instrumented drill to directly measure regolith properties (thermal, electrical, mechanical, and textural) and to determine the presence of water and other hydrogen sources to a depth of about 2 m (Prospector). CRUX surface and geophysical instruments (Surveyor) are designed to determine the presence of hydrogen, delineate near subsurface properties, stratigraphy, and buried objects over a broad area through the use of neutron and seismic probes, and ground penetrating radar. Techniques to receive data from existing space qualified stereo pair cameras to determine surface topography will also be part of the CRUX. The Mapper will ingest information from CRUX instruments and other lunar and planetary data sources, and provide data handling and display features for DSS output. CRUX operation will be semi-autonomous and near real-time to allow its use for either planning or operations purposes.
Richardson, Jeff; Iezzi, Angelo; Khan, Munir A
2015-08-01
Health state utilities measured by the major multi-attribute utility instruments differ. Understanding the reasons for this is important for the choice of instrument and for research designed to reconcile these differences. This paper investigates these reasons by explaining pairwise differences between utilities derived from six multi-attribute utility instruments in terms of (1) their implicit measurement scales; (2) the structure of their descriptive systems; and (3) 'micro-utility effects', scale-adjusted differences attributable to their utility formula. The EQ-5D-5L, SF-6D, HUI 3, 15D and AQoL-8D were administered to 8,019 individuals. Utilities and unweighted values were calculated using each instrument. Scale effects were determined by the linear relationship between utilities, the effect of the descriptive system by comparison of scale-adjusted values and 'micro-utility effects' by the unexplained difference between utilities and values. Overall, 66 % of the differences between utilities was attributable to the descriptive systems, 30.3 % to scale effects and 3.7 % to micro-utility effects. Results imply that the revision of utility algorithms will not reconcile differences between instruments. The dominating importance of the descriptive system highlights the need for researchers to select the instrument most capable of describing the health states relevant for a study. Reconciliation of inconsistent utilities produced by different instruments must focus primarily upon the content of the descriptive system. Utility weights primarily determine the measurement scale. Other differences, attributable to utility formula, are comparatively unimportant.
Gao, Lan; Xia, Li; Pan, Song-Qing; Xiong, Tao; Li, Shu-Chuen
2015-02-01
We aimed to gauge the burden of epilepsy in China from a societal perspective by estimating the direct, indirect and intangible costs. Patients with epilepsy and controls were enrolled from two tertiary hospitals in China. Patients were asked to complete a Cost-of-Illness (COI), Willingness-to-Pay (WTP) questionnaires, two utility elicitation instruments and Mini Mental State Examination (MMSE). Healthy controls only completed WTP questionnaire, and utility instruments. Univariate analyses were performed to investigate the differences in cost on the basis of different variables, while multivariate analysis was undertaken to explore the predictors of cost/cost component. In total, 141 epilepsy patients and 323 healthy controls were recruited. The median total cost, direct cost and indirect cost due to epilepsy were US$949.29, 501.34 and 276.72, respectively. Particularly, cost of anti-epileptic drugs (AEDs) (US$394.53) followed by cost of investigations (US$59.34), cost of inpatient and outpatient care (US$9.62) accounted for the majority of the direct medical costs. While patients' (US$103.77) and caregivers' productivity costs (US$103.77) constituted the major component of indirect cost. The intangible costs in terms of WTP value (US$266.07 vs. 88.22) and utility (EQ-5D, 0.828 vs. 0.923; QWB-SA, 0.657 vs. 0.802) were both substantially higher compared to the healthy subjects. Epilepsy is a cost intensive disease in China. According to the prognostic groups, drug-resistant epilepsy generated the highest total cost whereas patients in seizure remission had the lowest cost. AED is the most costly component of direct medical cost probably due to 83% of patients being treated by new generation of AEDs. Copyright © 2014 Elsevier B.V. All rights reserved.
Factorial and Structural Validity of Holland's Hexagonal Model for an Asian Student Population.
ERIC Educational Resources Information Center
Tay, Kenneth Kim; Hill, Joseph A.; Ward, Connie M.
A study examined the utility of Holland's hexagonal model as a culturally appropriate theoretical framework for U.S. career psychologists working with Asian international students. Chinese-descent international students enrolled in three Southeastern universities (n=170) completed three instruments: Holland's Self-Directed Search (SDS), an…
Richardson, Jeff; Khan, Munir A; Iezzi, Angelo; Maxwell, Aimee
2015-04-01
Cost utility analysis permits the comparison of disparate health services by measuring outcomes in comparable units, namely, quality-adjusted life-years, which equal life-years times the utility of the health state. However, comparability is compromised when different utility instruments predict different utilities for the same health state. The present paper measures the extent of, and reason for, differences between the utilities predicted by the EQ-5D-5L, SF-6D, HUI 3, 15D, QWB, and AQoL-8D. Data were obtained from patients in seven disease areas and members of the healthy public in six countries. Differences between public and patient utilities were estimated using each of the instruments. To explain discrepancies between the estimates, the measurement scales and content of the instruments were compared. The sensitivity of instruments to independently measured health dimensions was measured in pairwise comparisons of all combinations of the instruments. The difference between public and patient utilities varied with the choice of instrument by more than 50% for every disease group and in four of the seven groups by more than 100%. Discrepancies were associated with differences in both the instrument content and their measurement scales. Pairwise comparisons of instruments found that variation in the sensitivity to physical and psychosocial dimensions of health closely reflected the items in the instrument's descriptive systems. Results indicate that instruments measure related but different constructs. They imply that commonly used instruments systematically discriminate against some classes of services, most notably mental health services. Differences in the instrument scales imply the need for transformations between the instruments to increase the comparability of measurement. © The Author(s) 2014.
The 1983 direct strike lightning data, part 1
NASA Technical Reports Server (NTRS)
Thomas, Mitchel E.
1985-01-01
Data waveforms are presented which were obtained during the 1983 direct strike lightning tests utilizing the NASA F106-B aircraft specially instrumented for lightning electromagnetic measurements. The aircraft was operated in the vicinity of the NASA Langley Research Center, Hampton, Virginia, in a thunderstorm environment to elicit strikes. Electromagnetic field data and conduction currents on the aircraft were recorded for attached lightning. Part 1 contains 435 pages of lightning strike data in chart form.
The 1984 direct strike lightning data, part 3
NASA Technical Reports Server (NTRS)
Thomas, Mitchel E.; Carney, Harold K.
1986-01-01
Data waveforms are presented which were obtained during the 1984 direct-strike lightning tests utilizing the NASA F106-B aircraft specially instrumented for lightning electromagnetic measurements. The aircraft was operated in the vicinity of the NASA Langley Research Center, Hampton, Virginia, in a thunderstorm environment to elicit strikes. Electromagnetic field data and conduction currents on the aircraft were recorded for attached lightning. This is part 3, consisting entirely of charts and graphs.
The 1983 direct strike lightning data, part 2
NASA Technical Reports Server (NTRS)
Thomas, Mitchel E.
1985-01-01
Data waveforms are presented which were obtained during the 1983 direct strike lightning tests utilizing the NASA F106-B aircraft specially instrumented for lightning electromagnetic measurements. The aircraft was operated in the vicinity of the NASA Langley Research Center, Hampton, Virginia, in a thunderstorm environment to elicit strikes. Electromagnetic field data and conduction currents on the aircraft were recorded for attached lightning. Part 2 contains 443 pages of lightning strike data in chart form.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi; Pruski, Marek
Two-dimensional through-bond {sup 1}H({sup 13}C) solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse {sup 1}H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of {sup 1}H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N-formyl-l-methionyl-l-leucyl-l-phenylalanine (f-MLF-OH) and brown coal.
NASA Astrophysics Data System (ADS)
Mao, Kanmi; Pruski, Marek
2009-12-01
Two-dimensional through-bond 1H{ 13C} solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse 1H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of 1H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N- formyl- L-methionyl- L-leucyl- L-phenylalanine (f-MLF-OH) and brown coal.
BMSW - Fast Solar Wind Monitor - three years in orbit: Status and prospects
NASA Astrophysics Data System (ADS)
Prech, Lubomir; Zastenker, Georgy; Nemecek, Zdenek; Safrankova, Jana; Vaverka, Jakub; Cermak, Ivo; Chesalin, Lev S.; Gavrilova, Elena
Fast Solar Wind Monitor BMSW is an instrument flown as a part of the PLASMA-F complex onboard the Russian Spektr-R radioastronomical spacecraft. The spacecraft was launched on July 18, 2011. During the COSPAR-2014 Assembly meeting, the instrument is supposed to celebrate three successful years in operation. With a set of 6 Faraday’s cups, the instrument has a unique time resolution --- 0.5--1 s for a full energy spectrum (96 energy steps) and 31~ms for basic solar wind plasma parameters directing the instrument to study of fast solar wind discontinuities including interplanetary shocks, a fast variability of proton and alpha particle parameters, and to study of solar wind turbulence up to the ion kinetic scales. The measurement technique, its implementation, and ground data processing are discussed in the contribution. The performance of the instrument design and electronics are presented. We discuss heritage of this instrument utilized in design of future instruments being prepared for the further projects as Luna-Glob.
NASA Astrophysics Data System (ADS)
Parker, Tim; Devanney, Peter; Bainbridge, Geoff; Townsend, Bruce
2017-04-01
The march to make every type of seismometer, weak to strong motion, reliable and economically deployable in any terrestrial environment continues with the availability of three new sensors and seismic systems including ones with over 200dB of dynamic range. Until recently there were probably 100 pier type broadband sensors for every observatory type pier, not the types of deployments geoscientists are needing to advance science and monitoring capability. Deeper boreholes are now the recognized quieter environments for best observatory class instruments and these same instruments can now be deployed in direct burial environments which is unprecedented. The experiences of facilities in large deployments of broadband seismometers in continental scale rolling arrays proves the utility of packaging new sensors in corrosion resistant casings and designing in the robustness needed to work reliably in temporary deployments. Integrating digitizers and other sensors decreases deployment complexity, decreases acquisition and deployment costs, increases reliability and utility. We'll discuss the informed evolution of broadband pier instruments into the modern integrated field tools that enable economic densification of monitoring arrays along with supporting new ways to approach geoscience research in a field environment.
A validated methodology for determination of laboratory instrument computer interface efficacy
NASA Astrophysics Data System (ADS)
1984-12-01
This report is intended to provide a methodology for determining when, and for which instruments, direct interfacing of laboratory instrument and laboratory computers is beneficial. This methodology has been developed to assist the Tri-Service Medical Information Systems Program Office in making future decisions regarding laboratory instrument interfaces. We have calculated the time savings required to reach a break-even point for a range of instrument interface prices and corresponding average annual costs. The break-even analyses used empirical data to estimate the number of data points run per day that are required to meet the break-even point. The results indicate, for example, that at a purchase price of $3,000, an instrument interface will be cost-effective if the instrument is utilized for at least 154 data points per day if operated in the continuous mode, or 216 points per day if operated in the discrete mode. Although this model can help to ensure that instrument interfaces are cost effective, additional information should be considered in making the interface decisions. A reduction in results transcription errors may be a major benefit of instrument interfacing.
Mapping between 6 Multiattribute Utility Instruments.
Chen, Gang; Khan, Munir A; Iezzi, Angelo; Ratcliffe, Julie; Richardson, Jeff
2016-02-01
Cost-utility analyses commonly employ a multiattribute utility (MAU) instrument to estimate the health state utilities, which are needed to calculate quality-adjusted life years. Different MAU instruments predict significantly different utilities, which makes comparison of results from different evaluation studies problematical. This article presents mapping functions ("crosswalks") from 6 MAU instruments (EQ-5D-5L, SF-6D, Health Utilities Index 3 [HUI 3], 15D, Quality of Well-Being [QWB], and Assessment of Quality of Life 8D [AQoL-8D]) to each of the other 5 instruments in the study: a total of 30 mapping functions. Data were obtained from a multi-instrument comparison survey of the public and patients in 7 disease areas conducted in 6 countries (Australia, Canada, Germany, Norway, United Kingdom, and United States). The 8022 respondents were administered each of the 6 study instruments. Mapping equations between each instrument pair were estimated using 4 econometric techniques: ordinary least squares, generalized linear model, censored least absolute deviations, and, for the first time, a robust MM-estimator. Goodness-of-fit indicators for each of the results are within the range of published studies. Transformations reduced discrepancies between predicted utilities. Incremental utilities, which determine the value of quality-related health benefits, are almost perfectly aligned at the sample means. Transformations presented here align the measurement scales of MAU instruments. Their use will increase confidence in the comparability of evaluation studies, which have employed different MAU instruments. © The Author(s) 2015.
Quality of life instruments used in mental health research: properties and utilization.
Prigent, Amélie; Simon, Sandrine; Durand-Zaleski, Isabelle; Leboyer, Marion; Chevreul, Karine
2014-01-30
Quality of life (QoL) assessment is increasingly used in mental health. Multiple instruments exist, but the conditions for choosing one instrument over another for purposes of a specific study are not clear. We performed a systematic review to identify the QoL instruments used in mental health. The instruments were systematically described regarding their intrinsic properties (e.g., generic v. disease-specific) and their characteristics of utilization in studies (e.g., study objectives). Using cluster analyses, we investigated the existence of similar instruments with respect to each of these sets of characteristics and studied potential links between instruments' intrinsic properties and their characteristics of utilization. We included 149 studies in which 56 distinct instruments were used. Similarities were found among instruments in terms of their intrinsic properties as well as their characteristics of utilization, leading to the construction of four clusters of instruments in each case. However, no relevant links were identified between instruments' intrinsic properties and their characteristics of utilization, suggesting that the choice of QoL instruments did not depend on their properties. A consensus about common QoL instruments must be reached to facilitate the choice of instruments, the comparison of results and thus to have an impact on clinical and policy decision-making. © 2013 Published by Elsevier Ireland Ltd.
NASA Technical Reports Server (NTRS)
Jackson, F. C.
1984-01-01
The NASA K sub u band Radar Ocean Wave Spectrometer (ROWS) is an experimental prototype of a possible future satellite instrument for low data rate global waves measurements. The ROWS technique, which utilizes short pulse radar altimeters in a conical scan mode near vertical incidence to map the directional slope spectrum in wave number and azimuth, is briefly described. The potential of the technique is illustrated by some specific case studies of wave physical processes utilizing the aircraft ROWS data. These include: (1) an evaluation of numerical hindcast model performance in storm sea conditions, (2) a study of fetch limited wave growth, and (3) a study of the fully developed sea state. Results of these studies, which are briefly summarized, show how directional wave spectral observations from a mobile platform can contribute enormously to our understanding of wave physical processes.
Instrumental Assessment of Pediatric Dysphagia.
Arvedson, Joan C; Lefton-Greif, Maureen A
2017-04-01
Speech-language pathologists (SLPs) have fulfilled primary roles in the evaluation and management of children with feeding/swallowing disorders for more than five decades. The increased incidence and prevalence of newborns, infants, and children with feeding and swallowing disorders has resulted in increased use of instrumental swallowing evaluations. The videofluoroscopic swallow study and fiberoptic endoscopic evaluation of swallowing are the two most commonly used swallowing assessments by SLPs, with ultrasound used less frequently. This article focuses on updates over the past decade in the procedures and utility of instrumental assessments of swallowing function, and identifies future directions that may enable us to meet the needs of the children who are in our care to attain functional outcomes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Li, Li; Nguyen, Kim-Huong; Comans, Tracy; Scuffham, Paul
2018-04-01
Several utility-based instruments have been applied in cost-utility analysis to assess health state values for people with dementia. Nevertheless, concerns and uncertainty regarding their performance for people with dementia have been raised. To assess the performance of available utility-based instruments for people with dementia by comparing their psychometric properties and to explore factors that cause variations in the reported health state values generated from those instruments by conducting meta-regression analyses. A literature search was conducted and psychometric properties were synthesized to demonstrate the overall performance of each instrument. When available, health state values and variables such as the type of instrument and cognitive impairment levels were extracted from each article. A meta-regression analysis was undertaken and available covariates were included in the models. A total of 64 studies providing preference-based values were identified and included. The EuroQol five-dimension questionnaire demonstrated the best combination of feasibility, reliability, and validity. Meta-regression analyses suggested that significant differences exist between instruments, type of respondents, and mode of administration and the variations in estimated utility values had influences on incremental quality-adjusted life-year calculation. This review finds that the EuroQol five-dimension questionnaire is the most valid utility-based instrument for people with dementia, but should be replaced by others under certain circumstances. Although no utility estimates were reported in the article, the meta-regression analyses that examined variations in utility estimates produced by different instruments impact on cost-utility analysis, potentially altering the decision-making process in some circumstances. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fishbaugher, M. J.
1985-05-01
The decreasing cost of microcomputers along with improvements in power metering circuitry have changed the way in which electrical energy use is monitored. Although utilities still rely on kilowatt-hour (kWh) meters for billing purposes, a microcomputer-based monitoring system is used when greater temporal and end-use resolution is desired. Because these types of monitoring systems will be used increasingly in large-scale conservation and end-use studies, it is important that their performance be analyzed to determine their accuracy. A co-instrumentation test was devised in which two such microcomputer-based monitoring systems made simultaneous measurements of electrical end-uses in two commercial buildings. The analysismore » of the co-instrumentation data aids in the evaluation of microcomputer-based monitoring systems used for end-use measurements. Separate and independent data loggers were used to measure the same loads simultaneously. In addition to these two systems, a utility billing meter measured the total energy use in each building during the co-instrumentation test. The utility's meters provided a relatively accurate standard by which the performance of both loggers could be judged. The comparison between the SCL and PNL microcomputer-based loggers has shown that power measurement techniques directly affect system performance. The co-instrumentation test has shown that there are certain standards that a monitoring system must meet if it is to perform well. First, it is essential to calibrate a microcomputer-based logger against a known standard load before the system is installed. Second, a microcomputer-based system must have some way of accounting for power factors. Recent advances in power metering circuitry have made it relatively easy to apply these power factors automatically in real time.« less
Glassman, Steven D; Polly, David W; Dimar, John R; Carreon, Leah Y
2012-04-20
Cost effectiveness analysis for single-level instrumented fusion during a 5-year postoperative interval. To determine the cost/quality-adjusted life year (QALY) gained for single-level instrumented posterolateral lumbar fusion for degenerative lumbar spine conditions during a 5-year period. Cost/QALY has become a standard measure among healthcare economists because it is generic and can be used across medical treatments. Prior studies have reported widely variable estimates of cost/QALY for lumbar spine fusion. This variability may be related to factors including study design, sample population, baseline assumptions, and length of the observation period. To determine QALY, the Short Form 6D (SF-6D), a utility index derived from the Short Form (36) Health Survey (SF-36) was used. Cost analysis was performed based on actual reimbursements from third-party payors, including those for the index surgical procedure, treatment of complications, emergency room outpatient visits, and revision surgery. A second cost analysis using only the contemporaneous Medicare Fee schedule was also performed, in addition to a subanalysis including indirect costs from days off work. The mean SF-6D health utility value showed a gradual increase throughout the follow-up period. The mean health utility value gained in each year postoperatively was 0.12, 0.14, 0.13, 0.15, and 0.15, for a cumulative 0.69 QALY improvement during the 5-year interval. Mean direct medical costs based on actual reimbursements for 5 years after surgery, including the index and revision procedures, was $22,708. The resultant cost per QALY gained at the 5-year postoperative interval was $33,018. The analogous mean direct cost based on Medicare reimbursement for 5 years was $20,669, with a resultant cost per QALY gained of $30,053. The mean total work productivity cost for 5 years was $14,377. The resultant total cost (direct and indirect) per QALY gained ranged from $53,949 to $53,914 at 5 years postoperatively. In the future, surgeons will need to demonstrate cost-effectiveness as well as clinical efficacy in order to justify payment for medical and surgical interventions, including lumbar spine fusion. This study indicates that at 5-year follow-up, single-level instrumented posterolateral spine fusion is both effective and durable, resulting in a favorable cost/QALY gain compared to other widely accepted healthcare interventions.
Jorgensen, Chuck; Wheeler, Kevin
2002-03-01
Recent developments in neuroelectronics are applied to aviation and airplane flight control instruments. Electromyographic control has been applied to flight simulations using the autopilot interface in order to use gestures to give bank and pitch commands to the autopilot. In other demonstrations, direct rate control was used to perform repeated successful landings and the damage-adaptive capability of inner-loop neural and propulsion-based controls was utilized.
Developing an Acceptability Assessment of Preventive Dental Treatments
Hyde, Susan; Gansky, Stuart A.; Gonzalez-Vargas, Maria J.; Husting, Sheila R.; Cheng, Nancy F.; Millstein, Susan G.; Adams, Sally H.
2012-01-01
Objectives Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. Methods An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability. The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Results Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test–retest reliability, with identical time 1–time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). Conclusions The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations. PMID:18662256
Developing an acceptability assessment of preventive dental treatments.
Hyde, Susan; Gansky, Stuart A; Gonzalez-Vargas, Maria J; Husting, Sheila R; Cheng, Nancy F; Millstein, Susan G; Adams, Sally H
2009-01-01
Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test-retest reliability, with identical time 1-time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations.
NASA Technical Reports Server (NTRS)
Biddle, A. P.; Reynolds, J. M.
1986-01-01
The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.
Optical radiation measurements and instrumentation.
Andersen, F A; Landry, R J
1981-07-01
Accurate measurement of optical radiation is required when sources of optical radiation are used in biological research. Such measurement of broad-band noncoherent optical radiations usually must be performed by a highly trained specialist using sophisticated, complex, and expensive instruments. Presentation of the results of such measurement requires correct use of quantities and units with which many biological researchers are unfamiliar. The measurement process, quantities, units, measurement systems and instruments, and uncertainties associated with optical radiation measurements are reviewed in this paper. A conventional technique for evaluating the potential hazards associated with broad-band sources of optical radiation and a spectroradiometer developed to measure spectral quantities is described. A new prototype ultraviolet radiation hazard monitor which has recently been developed is also presented. This new instrument utilizes a spectrograph and a spectral weighting mechanical mask and provides a direct reading of the effective irradiance for wavelengths less than 315 nm.
Kopec, Jacek A; Sayre, Eric C; Rogers, Pamela; Davis, Aileen M; Badley, Elizabeth M; Anis, Aslam H; Abrahamowicz, Michal; Russell, Lara; Rahman, Md Mushfiqur; Esdaile, John M
2015-10-01
The CAT-5D-QOL is a previously reported item response theory (IRT)-based computerized adaptive tool to measure five domains (attributes) of health-related quality of life. The objective of this study was to develop and validate a multiattribute health utility (MAHU) scoring method for this instrument. The MAHU scoring system was developed in two stages. In phase I, we obtained standard gamble (SG) utilities for 75 hypothetical health states in which only one domain varied (15 states per domain). In phase II, we obtained SG utilities for 256 multiattribute states. We fit a multiplicative regression model to predict SG utilities from the five IRT domain scores. The prediction model was constrained using data from phase I. We validated MAHU scores by comparing them with the Health Utilities Index Mark 3 (HUI3) and directly measured utilities and by assessing between-group discrimination. MAHU scores have a theoretical range from -0.842 to 1. In the validation study, the scores were, on average, higher than HUI3 utilities and lower than directly measured SG utilities. MAHU scores correlated strongly with the HUI3 (Spearman ρ = 0.78) and discriminated well between groups expected to differ in health status. Results reported here provide initial evidence supporting the validity of the MAHU scoring system for the CAT-5D-QOL. Copyright © 2015 Elsevier Inc. All rights reserved.
Tarescavage, Anthony M; Wygant, Dustin B; Boutacoff, Lana I; Ben-Porath, Yossef S
2013-12-01
In the current study, we examined the reliability, validity, and clinical utility of Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF; Ben-Porath & Tellegen, 2011) scores in a sample of 759 bariatric surgery candidates. We provide descriptives for all scales, internal consistency and standard error of measurement estimates for all substantive scales, external correlates of substantive scales using chart review and self-report criteria, and relative risk ratios to assess the clinical utility of the instrument. Results generally support the reliability, validity, and clinical utility of MMPI-2-RF scale scores in the psychological evaluation of bariatric surgery candidates. Limitations, future directions, and practical application of these results are discussed. (c) 2013 APA, all rights reserved.
DART - LTQ ORBITRAP as an expedient tool for the identification of synthetic cannabinoids.
Habala, Ladislav; Valentová, Jindra; Pechová, Iveta; Fuknová, Mária; Devínsky, Ferdinand
2016-05-01
Synthetic cannabinoids as designer drugs constitute a major problem due to their rapid increase in number and the difficulties connected with their identification in complex mixtures. DART (Direct Analysis in Real Time) has emerged as an advantageous tool for the direct and rapid analysis of complex samples by mass spectrometry. Here we report on the identification of six synthetic cannabinoids originating from seized material in various matrices, employing the combination of ambient pressure ion source DART and hybrid ion trap - LTQ ORBITRAP mass spectrometer. This report also describes the sampling techniques for the provided herbal material containing the cannabinoids, either directly as plant parts or as an extract in methanol and their influence on the outcome of the analysis. The high resolution mass spectra supplied by the LTQ ORBITRAP instrument allowed for an unambiguous assignment of target compounds. The utilized instrumental coupling proved to be a convenient way for the identification of synthetic cannabinoids in real-world samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Thermal Modeling of the Mars Reconnaissance Orbiter's Solar Panel and Instruments during Aerobraking
NASA Technical Reports Server (NTRS)
Dec, John A.; Gasbarre, Joseph F.; Amundsen, Ruth M.
2007-01-01
The Mars Reconnaissance Orbiter (MRO) launched on August 12, 2005 and started aerobraking at Mars in March 2006. During the spacecraft s design phase, thermal models of the solar panels and instruments were developed to determine which components would be the most limiting thermally during aerobraking. Having determined the most limiting components, thermal limits in terms of heat rate were established. Advanced thermal modeling techniques were developed utilizing Thermal Desktop and Patran Thermal. Heat transfer coefficients were calculated using a Direct Simulation Monte Carlo technique. Analysis established that the solar panels were the most limiting components during the aerobraking phase of the mission.
Desikan, R; Mason, H L; Rupp, M T; Skehan, M
2002-12-01
The aim of this study was to compare the SF-36 and two disease-specific instruments--St. George's Respiratory Questionnaire (SGRQ) and Chronic Respiratory Disease Questionnaire (CRDQ) among chronic obstructive pulmonary disease (COPD) patients using healthcare utilization data. The three instruments were administered twice by telephone interview to 40 COPD patients separated by a 3-month interval. Healthcare utilization data were obtained for the 3 months immediately prior to each administration. Reliabilities for sub-scales on the three instruments ranged from 0.70 to 0.90 for the SF-36, from 0.78 to 0.85 for the SGRQ, and from 0.64 to 0.91 for the CRDQ. In general, the study sample had poor physical health, and somewhat better mental health. None of the demographic variables were significantly associated with either health status or utilization. Among the three instruments, the SF-36 explained the most variance in healthcare utilization. The aggregate scores such as the summary scores of the SF-36 and the total score of the SGRQ did not perform as well as the individual sub-scales of the respective instruments in explaining the variation in utilization. The conclusion that the SF-36 provides the best association to healthcare utilization data from among the three instruments studied should be interpreted with caution given the small sample size and relatively brief duration of the study.
Comparing the performance of the SF-6D and the EQ-5D in different patient groups.
Ferreira, Lara N; Ferreira, Pedro L; Pereira, Luis N
2014-01-01
This research aims to explore the performance of the SF-6D and the EQ-5D in patients suffering from asthma, chronic obstructive pulmonary disease, cataracts, and rheumatoid arthritis. In particular, the aim of this research is twofold: 1) to study the level of agreement between the indexes and the descriptive systems of the dimensions of the SF-6D and the EQ-5D, and 2) to analyze the discriminative ability of the instruments. A sample of 643 patients completed both the SF-36v2 and the EQ-5D. The discriminative ability of the instruments was analyzed. Furthermore, the level of agreement between the indexes and the descriptive systems of the dimensions of the SF-6D and the EQ-5D were studied. The level of agreement between instruments was investigated using correlation coefficients and the Bland-Altman plots, while the influence of medical condition and other socio-demographic variables was analyzed using nonparametric tests. Paired-samples tests were used to identify differences between the scores. The results show a strong correlation and agreement between both indexes. Overall, questionnaire indexes differ by medical condition and socio-demographic groups and both instruments are able to discriminate between socio-demographic groups. This study confirmed the hypothesis that the SF-6D generates higher utility values in less healthy individuals. The SF-6D and the EQ-5D seem to perform differently in each of the diseases studied since the descriptive statistics differ between instruments and the level of correlation is not uniform. Results show that the instruments generate different utility values, but there is a strong agreement between both indexes. Thus, the two instruments are not interchangeable and their results cannot be directly comparable.
An overview and the current status of instrumentation at the Large Binocular Telescope Observatory
NASA Astrophysics Data System (ADS)
Wagner, R. Mark; Edwards, Michelle L.; Kuhn, Olga; Thompson, David; Veillet, Christian
2014-07-01
An overview of instrumentation for the Large Binocular Telescope (LBT) is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (24' × 24') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the left and right direct F/15 Gregorian foci incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 2000. Infrared instrumentation includes the LBT Near-IR Spectrometer (LUCI), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at the left and right front-bent F/15 Gregorian foci and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 x 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development that can utilize the full 23 m baseline of the LBT include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near- infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). LBTI is currently undergoing commissioning and performing science observations on the LBT utilizing the installed adaptive secondary mirrors in both single-sided and two-sided beam combination modes. In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. Installation and testing of the bench spectrograph will begin in July 2014. Over the past four years the LBC pair, LUCI1, and MODS1 have been commissioned and are now scheduled for routine partner science observations. Both LUCI2 and MODS2 passed their laboratory acceptance milestones in the summer of 2013 and have been installed on the LBT. LUCI2 is currently being commissioned and the data analysis is well underway. Diffraction-limited commissioning of its adaptive optics modes will begin in the 2014B semester. MODS2 commissioning began in May 2014 and will completed in the 2014B semester as well. Binocular testing and commissioning of both the LUCI and MODS pairs will begin in 2014B with the goal that this capability could be offered sometime in 2015. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.
Evaluation of arctic broadband surface radiation measurements
NASA Astrophysics Data System (ADS)
Matsui, N.; Long, C. N.; Augustine, J.; Halliwell, D.; Uttal, T.; Longenecker, D.; Nievergall, O.; Wendell, J.; Albee, R.
2011-08-01
The Arctic is a challenging environment for making in-situ radiation measurements. A standard suite of radiation sensors is typically designed to measure the total, direct and diffuse components of incoming and outgoing broadband shortwave (SW) and broadband thermal infrared, or longwave (LW) radiation. Enhancements can include various sensors for measuring irradiance in various narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers) that rotate sensors and shading devices that track the sun. High quality measurements require striking a balance between locating sensors in a pristine undisturbed location free of artificial blockage (such as buildings and towers) and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data include solar tracker malfunctions, rime/frost/snow deposition on the instruments and operational problems due to limited operator access in extreme weather conditions. In this study, a comparison is made between the global and component sum (direct [vertical component] + diffuse) shortwave measurements. The difference between these two quantities (that theoretically should be zero) is used to illustrate the magnitude and seasonality of radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both shortwave and longwave measurements. Solutions to these operational problems are proposed that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols.
Rosa, Carmen; Ghitza, Udi; Tai, Betty
2012-07-17
Based on recommendations from a US Institute of Medicine report, the National Institute on Drug Abuse established the National Drug Abuse Treatment Clinical Trials Network (CTN) in 1999, to accelerate the translation of science-based addiction treatment research into community-based practice, and to improve the quality of addiction treatment, using science as the vehicle. One of the CTN's primary tasks is to serve as a platform to forge bi-directional communications and collaborations between providers and scientists, to enhance the relevance of research, which generates empirical results that impact practice. Among many obstacles in moving research into real-world settings, this commentary mainly describes challenges and iterative experiences in regard to how the CTN develops its research protocols, with focus on how the CTN study teams select and utilize assessment instruments, which can reasonably balance the interests of both research scientists and practicing providers when applied in CTN trials. This commentary also discusses the process by which the CTN further selects a core set of common assessment instruments that may be applied across all trials, to allow easier cross-study analyses of comparable data.
The OCO-3 Mission: Science Objectives and Instrument Performance
NASA Astrophysics Data System (ADS)
Eldering, A.; Basilio, R. R.; Bennett, M. W.
2017-12-01
The Orbiting Carbon Observatory 3 (OCO-3) will continue global CO2 and solar-induced chlorophyll fluorescence (SIF) using the flight spare instrument from OCO-2. The instrument is currently being tested, and will be packaged for installation on the International Space Station (ISS) (launch readiness in early 2018.) This talk will focus on the science objectives, updated simulations of the science data products, and the outcome of recent instrument performance tests. The low-inclination ISS orbit lets OCO-3 sample the tropics and sub-tropics across the full range of daylight hours with dense observations at northern and southern mid-latitudes (+/- 52º). The combination of these dense CO2 and SIF measurements provides continuity of data for global flux estimates as well as a unique opportunity to address key deficiencies in our understanding of the global carbon cycle. The instrument utilizes an agile, 2-axis pointing mechanism (PMA), providing the capability to look towards the bright reflection from the ocean and validation targets. The PMA also allows for a snapshot mapping mode to collect dense datasets over 100km by 100km areas. Measurements over urban centers could aid in making estimates of fossil fuel CO2 emissions. Similarly, the snapshot mapping mode can be used to sample regions of interest for the terrestrial carbon cycle. In addition, there is potential to utilize data from ISS instruments ECOSTRESS (ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station) and GEDI (Global Ecosystem Dynamics Investigation), which measure other key variables of the control of carbon uptake by plants, to complement OCO-3 data in science analysis. In 2017, the OCO-2 instrument was transformed into the ISS-ready OCO-3 payload. The transformed instrument was thoroughly tested and characterized. Key characteristics, such as instrument ILS, spectral resolution, and radiometric performance will be described. Analysis of direct sun measurements taken during testing will also be discussed.
Measuring the Sensitivity and Construct Validity of 6 Utility Instruments in 7 Disease Areas.
Richardson, Jeff; Iezzi, Angelo; Khan, Munir A; Chen, Gang; Maxwell, Aimee
2016-02-01
Health services that affect quality of life (QoL) are increasingly evaluated using cost utility analyses (CUA). These commonly employ one of a small number of multiattribute utility instruments (MAUI) to assess the effects of the health service on utility. However, the MAUI differ significantly, and the choice of instrument may alter the outcome of an evaluation. The present article has 2 objectives: 1) to compare the results of 3 measures of the sensitivity of 6 MAUI and the results of 6 tests of construct validity in 7 disease areas and 2) to rank the MAUI by each of the test results in each disease area and by an overall composite index constructed from the tests. Patients and the general public were administered a battery of instruments, which included the 6 MAUI, disease-specific QoL instruments (DSI), and 6 other comparator instruments. In each disease area, instrument sensitivity was measured 3 ways: by the unadjusted mean difference in utility between public and patient groups, by the value of the effect size, and by the correlation between MAUI and DSI scores. Content and convergent validity were tested by comparison of MAUI utilities and scores from the 6 comparator instruments. These included 2 measures of health state preferences, measures of subjective well-being and capabilities, and generic measures of physical and mental QoL derived from the SF-36. The apparent sensitivity of instruments varied significantly with the measurement method and by disease area. Validation test results varied with the comparator instruments. Notwithstanding this variability, the 15D, AQoL-8D, and the SF-6D generally achieved better test results than the QWB and EQ-5D-5L. © The Author(s) 2015.
NASA Technical Reports Server (NTRS)
Gorenstein, P.
1985-01-01
A program for the development of high throughput instrumentation for X-ray astronomy based upon focusing optics is being carried out by the Smithsonian Astrophysical Observatory. The instrumentation is applicable to investigations requiring large area focusing optics for direct imaging or dispersive spectroscopy. The long range goals of this program are the development of telescopes and gratings for future major X-ray astronomy facilities, including additions to the LAMAR OSS-2/SHEAL experiment after the initial flights. Tests of the devices and their more immediate utilization in scientific investigations can be carried out with SPARTAN payloads deployed and retrieved by the Space Shuttle. However, the present backlog of approved SPARTAN missions is longer than the three-year duration of the program described in this program. Laboratory studies and breadboarding of instrumentation are discussed.
Quantitative Hydrocarbon Surface Analysis
NASA Technical Reports Server (NTRS)
Douglas, Vonnie M.
2000-01-01
The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.
Comparing and transforming PROMIS utility values to the EQ-5D.
Hartman, John D; Craig, Benjamin M
2018-03-01
Summarizing patient-reported outcomes (PROs) on a quality-adjusted life year (QALY) scale is an essential component to any economic evaluation comparing alternative medical treatments. While multiple studies have compared PRO items and instruments based on their psychometric properties, no study has compared the preference-based summary of the EQ-5D-3L and Patient Reported Outcomes Measurement Information System (PROMIS-29) instruments. As part of this comparison, a major aim of this manuscript is to transform PROMIS-29 utility values to an EQ-5D-3L scale. A nationally representative survey of 2623 US adults completed the 29-item PROMIS health profile instrument (PROMIS-29) and the 3-level version of the EQ-5D instrument (EQ-5D-3L). Their responses were summarized on a health utility scale using published estimates. Using regression analysis, PROMIS-29 and EQ-5D-3L utility weights were compared with each other as well as with self-reported general health. PROMIS-29 utility weights were much lower than the EQ-5D-3L weights. However, a correlation coefficient of 0.769 between the utility values of the two instruments suggests that the main discordance is simply a difference in scale between the measures. It is also possible to map PROMIS-29 utility weights onto an EQ-5D-3L scale. EQ-5D-3L losses equal .1784 × (PROMIS-29 Losses) .7286 . The published estimates of the PROMIS-29 produce lower utility values than many other health instruments. Mapping the PROMIS-29 estimates to an EQ-5D-3L scale alleviates this issue and allows for a more straightforward comparison between the PROMIS-29 and other common health instruments.
Cascadia, an ultracompact seismic instrument with over 200dB of dynamic range
NASA Astrophysics Data System (ADS)
Parker, Tim; Devanney, Peter; Bainbridge, Geoff; Townsend, Bruce
2017-04-01
Integration of geophysical instrumentation is clearly a way to lower overall station cost, make installations less complex, reduce installation time, increase station utility and value to a wider group of researchers, data miners and monitoring groups. Initiatives to expand early earthquake warning networks and observatories can use these savings for increasing station density. Integration of mature instrument systems such as broadband sensors and accelerometers used in strong motion studies has to be done with care to preserve the low noise and low frequency performance while providing over 200dB of dynamic range. Understanding the instrument complexities and deployment challenges allows the engineering teams to optimize the packaging to make installation and servicing cost effective, simple, routine and ultimately more reliable. We discuss early results from testing both in the lab and in the field of a newly released instrument called the Cascadia that integrates a broadband seismometer with a class A (USGS rating) accelerometer in a small stainless steel sonde suited for dense arrays in either ad hoc direct bury field deployments or in observatory quality shallow boreholes.
Instruments to assess patient comfort during hospitalization: A psychometric review.
Lorente, Sonia; Losilla, Josep-Maria; Vives, Jaume
2018-05-01
To analyse the psychometric properties and the utility of instruments used to measure patient comfort, physical, social, psychospiritual and/or environmental, during hospitalization. There are no systematic reviews nor psychometric reviews of instruments used to measure comfort, which is considered an indicator of quality in health care associated with quicker discharges, increased patient satisfaction and better cost-benefit ratios for the institution. Psychometric review. MEDLINE, CINAHL, PsycINFO, Web of Knowledge, ProQuest Thesis&Dissertations, Google. We limited our search to studies published between 1990-2015. The psychometric analysis was performed using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN), along with the Quality Criteria for Measurement Properties. The utility of the instruments was assessed according to their cost-efficiency, acceptability and educational impact. Protocol registration in PROSPERO, CRD42016036290. Instruments reviewed showed moderate methodological quality and their utility was poorly reported. Thus, we cannot recommend any questionnaire without reservations, but the Comfort Scale, the General Comfort Questionnaire and their adaptations in adults and older patients, the Psychosocial Comfort Scale and the Incomfort des Patients de Reanimation are the most recommendable instruments to measure comfort. The methodology of the studies should be more rigorous and authors should adequately report the utility of instruments. This review provides a strategy to select the most suitable instrument to assess patient comfort according to their psychometric properties and utility, which is crucial for nurses, clinicians, researchers and institutions. © 2017 John Wiley & Sons Ltd.
Health state utilities among contemporary prostate cancer patients on active surveillance.
Loeb, Stacy; Curnyn, Caitlin; Walter, Dawn; Fagerlin, Angela; Siebert, Uwe; Mühlberger, Nick; Braithwaite, R Scott; Schwartz, Mark D; Lepor, Herbert; Sedlander, Erica
2018-04-01
Active surveillance (AS) is the most rapidly expanding management option for favorable-risk prostate cancer (PCa). Early studies suggested substantial decrements in utility (quality of life weights) from disease-related anxiety. Our objective was to determine utilities for contemporary AS patients using different instruments. We performed a systematic review of PubMed, PMC and OVID for utility measurements in modern AS patients. We then examined utilities among 37 men on AS participating in focus groups between 2015-2016 using the generic EurQol five dimensions questionnaire (EQ-5D-3L) and Patient Oriented Prostate Utility Scale (PORPUS), a PCa-specific instrument. The systematic review found previous studies with utilities for PCa treatment and historical watchful waiting populations, but none specifically in contemporary AS. In our AS population, the mean EQ-5D-3L score was 0.90±0.16 (median, 1.00; range, 0.21-1.00) and PORPUS was 0.98±0.03 (median, 0.99; range, 0.84-1.00). The Spearman correlation between the EQ-5D-3L and PORPUS was 0.87 (P<0.0001), and 38% of patients had a difference >0.1 between instruments. Most contemporary AS patients had high utility scores suggesting that they perceive themselves in good health without a major decrement in quality of life from the disease. However, some patients had substantial differences in utility measured with generic versus disease-specific instruments. Further study is warranted into the optimal instrument for utility assessment in contemporary AS patients.
Steiner, T J; Buse, D C; Al Jumah, M; Westergaard, M L; Jensen, R H; Reed, M L; Prilipko, L; Mennini, F S; Láinez, M J A; Ravishankar, K; Sakai, F; Yu, S-Y; Fontebasso, M; Al Khathami, A; MacGregor, E A; Antonaci, F; Tassorelli, C; Lipton, R B
2018-02-14
Headache disorders are both common and burdensome but, given the many people affected, provision of health care to all is challenging. Structured headache services based in primary care are the most efficient, equitable and cost-effective solution but place responsibility for managing most patients on health-care providers with limited training in headache care. The development of practical management aids for primary care is therefore a purpose of the Global Campaign against Headache. This manuscript presents an outcome measure, the Headache Under-Response to Treatment (HURT) questionnaire, describing its purpose, development, psychometric evaluation and assessment for clinical utility. The objective was a simple-to-use instrument that would both assess outcome and provide guidance to improving outcome, having utility across the range of headache disorders, across clinical settings and across countries and cultures. After literature review, an expert consensus group drawn from all six world regions formulated HURT through item development and item reduction using item-response theory. Using the American Migraine Prevalence and Prevention Study's general-population respondent panel, two mailed surveys assessed the psychometric properties of HURT, comparing it with other instruments as external validators. Reliability was assessed in patients in two culturally-contrasting clinical settings: headache specialist centres in Europe (n = 159) and primary-care centres in Saudi Arabia (n = 40). Clinical utility was assessed in similar settings (Europe n = 201; Saudi Arabia n = 342). The final instrument, an 8-item self-administered questionnaire, addressed headache frequency, disability, medication use and effect, patients' perceptions of headache "control" and their understanding of their diagnoses. Psychometric evaluation revealed a two-factor model (headache frequency, disability and medication use; and medication efficacy and headache control), with scale properties apparently stable across disorders and correlating well and in the expected directions with external validators. The literature review found few instruments linking assessment to clinical advice or suggested actions: HURT appeared to fill this gap. In European specialist care, it showed utility as an outcome measure across headache disorders. In Saudi Arabian primary care, HURT (translated into Arabic) was reliable and responsive to clinical change. With demonstrated validity and clinical utility across disorders, cultures and settings, HURT is available for clinical and research purposes.
Radar velocity determination using direction of arrival measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doerry, Armin W.; Bickel, Douglas L.; Naething, Richard M.
The various technologies presented herein relate to utilizing direction of arrival (DOA) data to determine various flight parameters for an aircraft A plurality of radar images (e.g., SAR images) can be analyzed to identify a plurality of pixels in the radar images relating to one or more ground targets. In an embodiment, the plurality of pixels can be selected based upon the pixels exceeding a SNR threshold. The DOA data in conjunction with a measurable Doppler frequency for each pixel can be obtained. Multi-aperture technology enables derivation of an independent measure of DOA to each pixel based on interferometric analysis.more » This independent measure of DOA enables decoupling of the aircraft velocity from the DOA in a range-Doppler map, thereby enabling determination of a radar velocity. The determined aircraft velocity can be utilized to update an onboard INS, and to keep it aligned, without the need for additional velocity-measuring instrumentation.« less
Bai, Yeon K; Dinour, Lauren M
2017-11-01
A proper assessment of multidimensional needs for breastfeeding mothers in various settings is crucial to facilitate and support breastfeeding and its exclusivity. The theory of planned behavior (TPB) has been used frequently to measure factors associated with breastfeeding. Full utility of the TPB requires accurate measurement of theory constructs. Research aim: This study aimed to develop and confirm the psychometric properties of an instrument, Milk Expression on Campus, based on the TPB and to establish the reliability and validity of the instrument. In spring 2015, 218 breastfeeding (current or in the recent past) employees and students at one university campus in northern New Jersey completed the online questionnaire containing demography and theory-based items. Internal consistency (α) and split-half reliability ( r) tests and factor analyses established and confirmed the reliability and construct validity of this instrument. Milk Expression on Campus showed strong and significant reliabilities as a full scale (α = .78, r = .74, p < .001) and theory construct subscales. Validity was confirmed as psychometric properties corresponded to the factors extracted from the scale. Four factors extracted from the direct construct subscales accounted for 79.49% of the total variability. Four distinct factors from the indirect construct subscales accounted for 73.68% of the total variability. Milk Expression on Campus can serve as a model TPB-based instrument to examine factors associated with women's milk expression behavior. The utility of this instrument extends to designing effective promotion programs to foster breastfeeding and milk expression behaviors in diverse settings.
ERIC Educational Resources Information Center
Marquardt, Lloyd D.; McCormick, Ernest J.
The study involved the use of a structured job analysis instrument called the Position Analysis Questionnaire (PAQ) as the direct basis for the establishment of the job component validity of aptitude tests (that is, a procedure for estimating the aptitude requirements for jobs strictly on the basis of job analysis data). The sample of jobs used…
Laser Scanner For Automatic Inspection Of Printed Wiring Boards
NASA Astrophysics Data System (ADS)
Geise, Philip; George, Eugene; Freese, Fritz; Brown, Robert; Ruwe, Victor
1980-11-01
An, Instrument is described which inspects unpopulated, populated (components onserted and leads clinched), and soldered printed wiring boards for correct hole location, component presence, correct lead clinch direction and solder bridges. The instrument consists of a low power heliumneon laser, an x-y moving iron galvanometer scanner and several folding mirros. A unique shadow signature is detected by silicon photodiodes located at the optium geometry to allow rapid and reliable detection of components with correctly clinched leads. A reflective glint screen is utilized to inspect for a solder bridges. The detected signal are processed and evaluated by a minocomputer which also controls the scan inspection rate of at least 25 components or 50 components holes per second. The return of investment on this instrument for high volume production of printed wirind boards is less than one yea and only slightly longer for medium run military application.
Report of the facility definition team spacelab UV-Optical Telescope Facility
NASA Technical Reports Server (NTRS)
1975-01-01
Scientific requirements for the Spacelab Ultraviolet-Optical Telescope (SUOT) facility are presented. Specific programs involving high angular resolution imagery over wide fields, far ultraviolet spectroscopy, precisely calibrated spectrophotometry and spectropolarimetry over a wide wavelength range, and planetary studies, including high resolution synoptic imagery, are recommended. Specifications for the mounting configuration, instruments for the mounting configuration, instrument mounting system, optical parameters, and the pointing and stabilization system are presented. Concepts for the focal plane instruments are defined. The functional requirements of the direct imaging camera, far ultraviolet spectrograph, and the precisely calibrated spectrophotometer are detailed, and the planetary camera concept is outlined. Operational concepts described in detail are: the makeup and functions of shuttle payload crew, extravehicular activity requirements, telescope control and data management, payload operations control room, orbital constraints, and orbital interfaces (stabilization, maneuvering requirements and attitude control, contamination, utilities, and payload weight considerations).
Huppertz-Hauss, Gert; Aas, Eline; Lie Høivik, Marte; Langholz, Ebbe; Odes, Selwyn; Småstuen, Milada; Stockbrugger, Reinhold; Hoff, Geir; Moum, Bjørn; Bernklev, Tomm
2016-01-01
Background. The treatment of chronic inflammatory bowel disease (IBD) is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D) and the Euro QoL (EQ-5D), two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36) was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.
Aas, Eline; Odes, Selwyn; Småstuen, Milada; Stockbrugger, Reinhold; Hoff, Geir; Moum, Bjørn; Bernklev, Tomm
2016-01-01
Background. The treatment of chronic inflammatory bowel disease (IBD) is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D) and the Euro QoL (EQ-5D), two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36) was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution. PMID:27630711
Smaldone, Arlene; Tsimicalis, Argerie; Stone, Patricia W
2011-01-01
In the United States, rising health care costs have led to discussion about bending the cost curve. To understand the true burden of disease and its treatment, costs of care, including those incurred by patients and their families, must be comprehensively assessed using psychometrically sound instruments. The Resource Utilization Questionnaire (RUQ) is a 21-item self-report questionnaire first developed to measure the costs incurred by families of infants who had required intensive care during the newborn period. The purpose of this article is to describe the conceptualization of resource utilization and costs and other methodological issues in conducting economic analyses, the process of adapting the RUQ for use in children and families with Type 1 diabetes mellitus (T1DM), and the psychometric evaluation to establish content and criterion validity of the instrument. The finalized modified RUQ for T1DM (mRUQ-T1DM) contained 25 items reflecting direct (5 items) and nondirect (3 items) health care, patient/family time (8 items), and patient/family productivity (9 items) costs using a 3-month recall. The mRUQ-T1DM validly measures cost incurred by children and families with T1DM and is easily completed by parents. Furthermore, the mRUQ-T1DM may be adapted for use in other populations using a similar process.
Hyperspectral Sun Photometer for Atmospheric Characterization and Vicarious Calibrations
NASA Technical Reports Server (NTRS)
Pagnutti, Mary; Ryan, Robert; Holekamp, Kara
2008-01-01
A hyperspectral sun photometer and associated methods have been developed and demonstrated. Accurate sun photometer calibration is critical to properly measure the solar irradiance and characterize the atmosphere. Traditional sun photometer calibration requires solar observations over several hours. In contrast, the procedures for operating this photometer entail less data acquisition time and embody a more direct approach to calibration. The scientific value of the measurement data produced by this instrument is not adversely affected by atmospheric instability. In addition, this instrument yields hyperspectral data covering a large spectral range (350-2,500 nm) not available from most traditional sun photometers. The hyperspectral sun photometer components include (1) a commercially available spectroradiometer that has been laboratory-calibrated and (2) a commercially available reflectance standard panel that exhibits nearly Lambertian 99% reflectance. The spectroradiometer is positioned above, and aimed downward at, the panel. The procedure for operating this instrument calls for a series of measurements: one in which the panel is fully illuminated by the sun, one in which a shade is positioned between the panel and the sun, and two in which the shade is positioned to cast a shadow to either side of the panel. The total sequence of measurements can be performed in less than a minute. From these measurements, the total radiance, the diffuse radiance, and the direct solar radiance are calculated. The direct solar irradiance is calculated from the direct solar radiance and the known reflectance factor of the panel as a function of the solar zenith angle. Atmospheric characteristics are estimated from the optical depth at various wavelengths calculated from (1) the direct solar irradiance obtained as described above, (2) the air mass along a column from the measurement position to the Sun, and (3) the top-of-atmosphere solar irradiance. The instrumentation used to implement the sun photometer is the same as that used to characterize targets used in radiometric vicarious calibrations. Utilizing this type of sun photometer thus reduces the amount of instrumentation and labor required to perform these studies.
Ferraz, C C; Gomes, N V; Gomes, B P; Zaia, A A; Teixeira, F B; Souza-Filho, F J
2001-07-01
To evaluate the weight of debris and irrigant volume extruded apically from extracted teeth in vitro after endodontic instrumentation using the balanced force technique, a hybrid hand instrumentation technique, and three engine-driven techniques utilizing nickel-titanium instruments (ProFile .04, Quantec 2000 and Pow-R). Five groups of 20 extracted human teeth with single canals were instrumented using one or other of five techniques: balanced force, hybrid, Quantec 2000, ProFile .04, or Pow-R. Debris extruded from the apical foramen during instrumentation were collected into preweighed 1.5 mL tubes. Following instrumentation, the volume of extruded irrigant fluid was determined by visual comparison to control centrifuge tubes filled with 0.25 mL increments of distilled water. The weight of dry extruded dentine debris was also established. Overall, the engine-driven techniques extruded less debris than the manual ones. However, there was no statistical difference between the balanced force technique and the engine-driven methods. The volume of irrigant extruded through the apex was directly associated with the weight of extruded debris, except within the ProFile group. The hybrid technique was associated with the greatest extrusion of both debris and irrigant. Overall, the engine-driven nickel-titanium systems were associated with less apical extrusion.
Sabatelli, Lorenzo
2016-01-01
Income and price elasticity of demand quantify the responsiveness of markets to changes in income and in prices, respectively. Under the assumptions of utility maximization and preference independence (additive preferences), mathematical relationships between income elasticity values and the uncompensated own and cross price elasticity of demand are here derived using the differential approach to demand analysis. Key parameters are: the elasticity of the marginal utility of income, and the average budget share. The proposed method can be used to forecast the direct and indirect impact of price changes and of financial instruments of policy using available estimates of the income elasticity of demand. PMID:26999511
Sabatelli, Lorenzo
2016-01-01
Income and price elasticity of demand quantify the responsiveness of markets to changes in income and in prices, respectively. Under the assumptions of utility maximization and preference independence (additive preferences), mathematical relationships between income elasticity values and the uncompensated own and cross price elasticity of demand are here derived using the differential approach to demand analysis. Key parameters are: the elasticity of the marginal utility of income, and the average budget share. The proposed method can be used to forecast the direct and indirect impact of price changes and of financial instruments of policy using available estimates of the income elasticity of demand.
Brennan; Biddison; Frauendorf; Schwarcz; Keen; Ecker; Davis; Tinder; Swayze
1998-01-01
An automated, 96-well parallel array synthesizer for solid-phase organic synthesis has been designed and constructed. The instrument employs a unique reagent array delivery format, in which each reagent utilized has a dedicated plumbing system. An inert atmosphere is maintained during all phases of a synthesis, and temperature can be controlled via a thermal transfer plate which holds the injection molded reaction block. The reaction plate assembly slides in the X-axis direction, while eight nozzle blocks holding the reagent lines slide in the Y-axis direction, allowing for the extremely rapid delivery of any of 64 reagents to 96 wells. In addition, there are six banks of fixed nozzle blocks, which deliver the same reagent or solvent to eight wells at once, for a total of 72 possible reagents. The instrument is controlled by software which allows the straightforward programming of the synthesis of a larger number of compounds. This is accomplished by supplying a general synthetic procedure in the form of a command file, which calls upon certain reagents to be added to specific wells via lookup in a sequence file. The bottle position, flow rate, and concentration of each reagent is stored in a separate reagent table file. To demonstrate the utility of the parallel array synthesizer, a small combinatorial library of hydroxamic acids was prepared in high throughput mode for biological screening. Approximately 1300 compounds were prepared on a 10 μmole scale (3-5 mg) in a few weeks. The resulting crude compounds were generally >80% pure, and were utilized directly for high throughput screening in antibacterial assays. Several active wells were found, and the activity was verified by solution-phase synthesis of analytically pure material, indicating that the system described herein is an efficient means for the parallel synthesis of compounds for lead discovery. Copyright 1998 John Wiley & Sons, Inc.
DMDs for multi-object near-infrared spectrographs in astronomy
NASA Astrophysics Data System (ADS)
Smee, Stephen A.; Barkhouser, Robert; Hope, Stephen; Conley, Devin; Gray, Aidan; Hope, Gavin; Robberto, Massimo
2018-02-01
The Digital Micromirror Device (DMD), typically used in projection screen technology, has utility in instrumentation for astronomy as a digitally programmable slit in a spectrograph. When placed at an imaging focal plane the device can be used to selectively direct light from astronomical targets into the optical path of a spectrograph, while at the same time directing the remaining light into an imaging camera, which can be used for slit alignment, science imaging, or both. To date the use of DMDs in astronomy has been limited, especially for instruments that operate in the near infrared (1 - 2.5 μm). This limitation is due in part to a host of technical challenges with respect to DMDs that, to date, have not been thoroughly explored. Those challenges include operation at cryogenic temperature, control electronics that facilitate DMD use at these temperatures, window coatings properly coated for the near infrared bandpass, and scattered light. This paper discusses these technical challenges and presents progress towards understanding and mitigating them.
[Expectations of hospital administrators about administrative functions of nurses].
Melo, M R; Fávero, N; Trevizan, M A; Hayashida, M
1996-01-01
The objective of the present study was to investigate hospital administrator's expectations about the administrative role played by nurses, utilizing functions proposed by the Neoclassical Theory of Administration: planning, organization, direction, and control as theoretical references. An instrument established in TREVIZAN (1989) was applied to 11 hospital administrators. The results showed they expect the four functions to be done by nurses. Therefore, the interaction between nurses and hospital administrators is critical to improve the patient's assistance.
Accelerator Test of an Imaging Calorimeter
NASA Technical Reports Server (NTRS)
Christl, Mark J.; Adams, James H., Jr.; Binns, R. W.; Derrickson, J. H.; Fountain, W. F.; Howell, L. W.; Gregory, J. C.; Hink, P. L.; Israel, M. H.; Kippen, R. M.;
2001-01-01
The Imaging Calorimeter for ACCESS (ICA) utilizes a thin sampling calorimeter concept for direct measurements of high-energy cosmic rays. The ICA design uses arrays of small scintillating fibers to measure the energy and trajectory of the produced cascades. A test instrument has been developed to study the performance of this concept at accelerator energies and for comparison with simulations. Two test exposures have been completed using a CERN test beam. Some results from the accelerator tests are presented.
Deriving health utilities from the MacNew Heart Disease Quality of Life Questionnaire.
Chen, Gang; McKie, John; Khan, Munir A; Richardson, Jeff R
2015-10-01
Quality of life is included in the economic evaluation of health services by measuring the preference for health states, i.e. health state utilities. However, most intervention studies include a disease-specific, not a utility, instrument. Consequently, there has been increasing use of statistical mapping algorithms which permit utilities to be estimated from a disease-specific instrument. The present paper provides such algorithms between the MacNew Heart Disease Quality of Life Questionnaire (MacNew) instrument and six multi-attribute utility (MAU) instruments, the Euroqol (EQ-5D), the Short Form 6D (SF-6D), the Health Utilities Index (HUI) 3, the Quality of Wellbeing (QWB), the 15D (15 Dimension) and the Assessment of Quality of Life (AQoL-8D). Heart disease patients and members of the healthy public were recruited from six countries. Non-parametric rank tests were used to compare subgroup utilities and MacNew scores. Mapping algorithms were estimated using three separate statistical techniques. Mapping algorithms achieved a high degree of precision. Based on the mean absolute error and the intra class correlation the preferred mapping is MacNew into SF-6D or 15D. Using the R squared statistic the preferred mapping is MacNew into AQoL-8D. The algorithms reported in this paper enable MacNew data to be mapped into utilities predicted from any of six instruments. This permits studies which have included the MacNew to be used in cost utility analyses which, in turn, allows the comparison of services with interventions across the health system. © The European Society of Cardiology 2014.
A 3D NO2 DOAS System to Capture Urban Concentrations
NASA Astrophysics Data System (ADS)
Wenig, M.; Chan, L.; Zhu, Y.; Schütt, A. M. N.; Kuhlmann, G.; Brunner, D.
2016-12-01
The Munich 3D DOAS measuring system combines four different types of DOAS measurement techniques and is installed on the roof of the building of the LMU Meteorological Institute at the center of Munich. In order to get a complete picture of the NO2 distribution we utilize a sensor fusion concept consisting of three longpath-DOAS instruments (LP-DOAS) scanning retroreflectors in different directions and distances, a multi-axis DOAS instrument (MAX-DOAS) performing elevation scans in different azimuth directions which is also capable to look directly into the sun allowing direct sun DOAS measurements, and a mobile cavity-enhanced DOAS instruments (CE-DOAS) capturing the citywide street level NO2 concentrations.The map from the mobile CE-DOAS is corrected for diurnal variations using the LP-DOAS data and a daily cycle analysis to get a consistent NO2 map. The LP-DOAS data averages over several kilometers and uses different measurement paths to capture the horizontal variations at roof top level. This data set will also be used to constrain the vertical profile shapes retrieved from the MAX-DOAS inversion. Constraining ground concentrations using the LP-DOAS and the total columns from the direct sun DOAS measurements allows us to retrieve additional profile parameters characterizing a radial component of fitted profiles which then leads to estimated 3D distributions putting together different azimuth scan results.The resulting data set is very valuable for satellite validation (e.g. OMI NO2) since we cover an area similar to an OMI ground pixel and provide the vertical profile to eliminate the biggest error source for the AMF calculation for the retrieval algorithm. We are also comparing our results to local measurement stations.
In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence
NASA Technical Reports Server (NTRS)
Sarrazin, P.; Blake, D.; Vaniman, D.; Chang, Sherwood (Technical Monitor)
1996-01-01
Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.
NASA Astrophysics Data System (ADS)
Adkins, K. A.; Sescu, A.
2016-12-01
Simulation and modeling have shown that wind farms have an impact on the near-surface atmospheric boundary layer (ABL) as turbulent wakes generated by the turbines enhance vertical mixing. These changes alter downstream atmospheric properties. With a large portion of wind farms hosted within an agricultural context, changes to the environment can potentially have secondary impacts such as to the productivity of crops. With the exception of a few observational data sets that focus on the impact to near-surface temperature, little to no observational evidence exists. These few studies also lack high spatial resolution due to their use of a limited number of meteorological towers or remote sensing techniques. This study utilizes an instrumented small unmanned aerial system (sUAS) to gather in-situ field measurements from two Midwest wind farms, focusing on the impact that large utility-scale wind turbines have on relative humidity. Wind turbines are found to differentially alter the relative humidity in the downstream, spanwise and vertical directions under a variety of atmospheric stability conditions.
NASA Technical Reports Server (NTRS)
Acton, Charles H., Jr.; Bachman, Nathaniel J.; Semenov, Boris V.; Wright, Edward D.
2010-01-01
The Navigation Ancillary Infor ma tion Facility (NAIF) at JPL, acting under the direction of NASA s Office of Space Science, has built a data system named SPICE (Spacecraft Planet Instrument Cmatrix Events) to assist scientists in planning and interpreting scientific observations (see figure). SPICE provides geometric and some other ancillary information needed to recover the full value of science instrument data, including correlation of individual instrument data sets with data from other instruments on the same or other spacecraft. This data system is used to produce space mission observation geometry data sets known as SPICE kernels. It is also used to read SPICE kernels and to compute derived quantities such as positions, orientations, lighting angles, etc. The SPICE toolkit consists of a subroutine/ function library, executable programs (both large applications and simple utilities that focus on kernel management), and simple examples of using SPICE toolkit subroutines. This software is very accurate, thoroughly tested, and portable to all computers. It is extremely stable and reusable on all missions. Since the previous version, three significant capabilities have been added: Interactive Data Language (IDL) interface, MATLAB interface, and a geometric event finder subsystem.
The construction of a high resolution crystal backscattering spectrometer HERMES I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larese, J.Z.
There is a need in the United States for a state-of-the-art, cold-neutron, crystal backscattering spectrometer (CBS) designed to investigate the structure and dynamics of condensed matter systems by the simultaneous utilization of long wavelength elastic diffraction and high-energy-resolution inelastic scattering. Cold neutron spectroscopy with CBS-type instruments has already made many important contributions to the study of atomic and molecular diffusion in biomaterials, polymers, semiconductors, liquid crystals, superionic conductors and the like. Such instruments have also been invaluable for ultra high resolution investigations of the low-lying quantum tunneling processes that provide direct insight into the dynamical response of solids at themore » lowest energies. Until relatively recently, however, all such instruments were located at steady-state reactors. This proposal describes HERMES I (High Energy Resolution Machines I) a CBS intended for installation at the LANSCE pulsed neutron facility of Los Alamos National Laboratory. As explained in detail in the main text, the authors propose to construct an updated, high-performance CBS which incorporates neutron techniques developed during the decade since IRIS was built, i.e., improved supermirror technology, a larger area crystal analyzer and high efficiency wire gas detectors. The instrument is designed in such a way as to be readily adaptable to future upgrades. HERMES I, they believe, will substantially expand the range and flexibility of neutron investigations in the United States and open new and potentially fruitful directions for condensed matter exploration. This document describes a implementation plan with a direct cost range between $4.5 to 5.6 M and scheduled duration of 39--45 months for identified alternatives.« less
NASA Technical Reports Server (NTRS)
McGill, Matthew; Famiglietti, Joe
2005-01-01
Researchers at NASA's Goddard Space Flight Center have developed an autonomous aerosol backscatter lidar instrument for use on the high-altitude ER-2 aircraft (for more information please visit http://cpl.gsfc.nasa.gov). Work is currently underway to transfer this instrument to a UAV platform such as Global Hawk. While the NASA applications are Earth science and satellite validation, there is clearly a Homeland Security application for such an instrument. One novel concept is to have a fleet of UAVs stationed around the country, each UAV having a payload including a lidar instrument. In the event of attack, the appropriate UAV(s) could be launched for purposes of, e.g., plume detection and tracking that are critical for decision support. While the existing lidar instrument is not directly capable of biological species discrimination, it is capable of plume tracking and thus can demonstrate to DHS the capabilities and utility of such instruments. Using NASA funding we will have an instrument ready to fly on Global Hawk by end of 2005. We would like to find partners, either within private industry or within DHS who would be willing to contribute aircraft access and flight hours for a demonstration flight. Longer-term partnerships to develop more advanced and more capable types of lidar instruments are also desirable. In this presentation we will detail the existing ER-2 lidar instrument and show measurement results, show the progress made on adapting to the Global Hawk platform, present concepts for DHS uses of such instruments, and openly pursue partnership opportunities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wemple, R.P.; Meyer, R.D.; Jacobson, R.D.
This work in partnership with industry is a continuation of cost- effective innovative, directional boring development begun in FY90 and planed to extend into FY94. Several demonstrations of the strategy of building hybrid hardware from utilities installation, geothermal, and soil mechanics technologies have been performed at Sandia National Laboratories (SNL) and at Charles Machine works (CMW) test sites as well as at a commercial refinery site. Additional tests at the SNL Directional Boring Test Range (DBTR) and a lagoon site are planned in calendar 1991. A new companion project to develop and demonstrate a hybrid capability for horizontal logging withmore » penetrometers, specialty instruments and samplers has been taken from concept to early prototype hardware. The project goal of extending the tracking/locating capability of the shallow boring equipment to 80in. is being pursued with encouraging results at 40in. depths. Boring costs, not including tailored well completions dictated by individual site parameters, are estimated at $20 to $50 per foot. Applications continue to emerge for this work and interest continues to be expressed by DoD and EPA researchers and environmental site engineers. 12 figs.« less
Scoping review of instruments measuring attitudes toward disability.
Palad, Yves Y; Barquia, Rensyl B; Domingo, Harvey C; Flores, Clinton K; Padilla, Levin I; Ramel, Jonas Mikko D
2016-07-01
Negative attitudes toward disability cause difficulties in integrating persons with disabilities (PWDs) into society and limit their access to health care, education, employment, and leisure. Being aware of societal attitudes toward disability may help explain discrimination against PWDs and draw attention to the solutions needed to address these. Good measures of attitudes are vital for this purpose. The aim is to synthesize published information, including evidences on psychometric properties and overall utility on instruments that measure attitudes toward disability. A two-tiered search process was performed to identify instruments that measure attitudes toward disability and retrieve articles that describe their development and/or validation. The CanChild Outcome Measures Rating Form was utilized to determine the overall utility of the instruments. Results were synthesized using a self-constructed data extraction form. Thirty-one instruments were included in the study. Five measured attitudes toward communication disability, 7 toward intellectual disability, 4 toward mental illness, and 15 toward disability in general. Target respondents ranged from children to adults, and included respondents from different occupations and cultural backgrounds. Twenty-three were found to have adequate overall utility, while 8 have poor overall utility. Several instruments are available in literature and all may be used for their intended purposes as long as their limitations are considered. Many still require further validation to ascertain their validity and responsiveness to change. Copyright © 2016 Elsevier Inc. All rights reserved.
Maxey, C.; Andreas, A.
2009-02-03
A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.
Increased Science Instrumentation Funding Strengthens Mars Program
NASA Technical Reports Server (NTRS)
Graham, Lee D.; Graff, T. G.
2012-01-01
As the strategic knowledge gaps mature for the exploration of Mars, Mars sample return (MSR), and Phobos/Deimos missions, one approach that becomes more probable involves smaller science instrumentation and integrated science suites. Recent technological advances provide the foundation for a significant evolution of instrumentation; however, the funding support is currently too small to fully utilize these advances. We propose that an increase in funding for instrumentation development occur in the near-term so that these foundational technologies can be applied. These instruments would directly address the significant knowledge gaps for humans to Mars orbit, humans to the Martian surface, and humans to Phobos/ Deimos. They would also address the topics covered by the Decadal Survey and the Mars scientific goals, objectives, investigations and priorities as stated by the MEPAG. We argue that an increase of science instrumentation funding would be of great benefit to the Mars program as well as the potential for human exploration of the Mars system. If the total non-Earth-related planetary science instrumentation budget were increased 100% it would not add an appreciable amount to the overall NASA budget and would provide the real potential for future breakthroughs. If such an approach were implemented in the near-term, NASA would benefit greatly in terms of science knowledge of the Mars, Phobos/Deimos system, exploration risk mitigation, technology development, and public interest.
Clinical utility of measures of breathlessness.
Cullen, Deborah L; Rodak, Bernadette
2002-09-01
The clinical utility of measures of dyspnea has been debated in the health care community. Although breathlessness can be evaluated with various instruments, the most effective dyspnea measurement tool for patients with chronic lung disease or for measuring treatment effectiveness remains uncertain. Understanding the evidence for the validity and reliability of these instruments may provide a basis for appropriate clinical application. Evaluate instruments designed to measure breathlessness, either as single-symptom or multidimensional instruments, based on psychometrics foundations such as validity, reliability, and discriminative and evaluative properties. Classification of each dyspnea measurement instrument will recommend clinical application in terms of exercise, benchmarking patients, activities of daily living, patient outcomes, clinical trials, and responsiveness to treatment. Eleven dyspnea measurement instruments were selected. Each instrument was assessed as discriminative or evaluative and then analyzed as to its psychometric properties and purpose of design. Descriptive data from all studies were described according to their primary patient application (ie, chronic obstructive pulmonary disease, asthma, or other patient populations). The Borg Scale and the Visual Analogue Scale are applicable to exertion and thus can be applied to any cardiopulmonary patient to determine dyspnea. All other measures were determined appropriate for chronic obstructive pulmonary disease, whereas the Shortness of Breath Questionnaire can be applied to cystic fibrosis and lung transplant patients. The most appropriate utility for all instruments was measuring the effects on activities of daily living and for benchmarking patient progress. Instruments that quantify function and health-related quality of life have great utility for documenting outcomes but may be limited as to documenting treatment responsiveness in terms of clinically important changes. The dyspnea measurement instruments we studied meet important standards of validity and reliability. Discriminative measures have limited clinical utility and, when used for populations or conditions for which they are not designed or validated, the data collected may not be clinically relevant. Evaluative measures have greater clinical utility and can be applied for outcome purposes. Measures should be applied to the populations and conditions for which they were designed. The relationship between clinical therapies and the measurement of dyspnea as an outcome can develop as respiratory therapists become more comfortable with implementing dyspnea measurement instruments and use the data to improve patient treatment. Dyspnea evaluation should be considered for all clinical practice guidelines and care pathways.
Michel, Anna P M; Kapit, Jason; Witinski, Mark F; Blanchard, Romain
2017-04-10
Methane is a powerful greenhouse gas that has both natural and anthropogenic sources. The ability to measure methane using an integrated path length approach such as an open/long-path length sensor would be beneficial in several environments for examining anthropogenic and natural sources, including tundra landscapes, rivers, lakes, landfills, estuaries, fracking sites, pipelines, and agricultural sites. Here a broadband monolithic distributed feedback-quantum cascade laser array was utilized as the source for an open-path methane sensor. Two telescopes were utilized for the launch (laser source) and receiver (detector) in a bistatic configuration for methane sensing across a 50 m path length. Direct-absorption spectroscopy was utilized with intrapulse tuning. Ambient methane levels were detectable, and an instrument precision of 70 ppb with 100 s averaging and 90 ppb with 10 s averaging was achieved. The sensor system was designed to work "off the grid" and utilizes batteries that are rechargeable with solar panels and wind turbines.
A technique for open trocar placement in laparoscopic surgery using the umbilical cicatrix tube.
Lal, Pawanindra; Sharma, R; Chander, R; Ramteke, V K
2002-09-01
Increasingly the open method for placement of the initial or first trocar is replacing the conventional technique with the Veress needle. Indeed, it is preferred because it affords peritoneal access under direct vision. A number of methods have been described in the literature using a variety of approaches and different instruments. We describe a method of open trocar placement in the supra- or subumbilical region that follows a stepwise procedure and employs specific instruments sequentially, while utilizing the umbilical cicatrix pillar or tube. This technique has been done in 525 cases with no complications or port site hernias. This is a simple technique that is safe and easy to learn. It can be performed rapidly and is a reliable method for the insertion of the first port under vision.
NASA Astrophysics Data System (ADS)
Kaplan, Alexis C.; Henzl, Vladimir; Menlove, Howard O.; Swinhoe, Martyn T.; Belian, Anthony P.; Flaska, Marek; Pozzi, Sara A.
2014-11-01
As a part of the Next Generation Safeguards Initiative Spent Fuel project, we simulate the response of the Differential Die-away Self-Interrogation (DDSI) instrument to determine total elemental plutonium content in an assayed spent nuclear fuel assembly (SFA). We apply recently developed concepts that relate total plutonium mass with SFA multiplication and passive neutron count rate. In this work, the multiplication of the SFA is determined from the die-away time in the early time domain of the Rossi-Alpha distributions measured directly by the DDSI instrument. We utilize MCNP to test the method against 44 pressurized water reactor SFAs from a simulated spent fuel library with a wide dynamic range of characteristic parameters such as initial enrichment, burnup, and cooling time. Under ideal conditions, discounting possible errors of a real world measurement, a root mean square agreement between true and determined total Pu mass of 2.1% is achieved.
Besier, Tanja; Ziegenhain, Ute; Fegert, Jörg M; Künster, Anne Katrin
2012-01-01
Prognostic evaluation of child development in the context of his/her actual family situation plays an important role in family law disputes. However, there is a lack of empirically validated instruments to assess socio-emotional development in very young children. Attachment research provides instruments which could be utilized in clinical practice. At this, the focus should be on assessing the quality of parent-child-relationship and the occurrence of risky parenting behaviour. The article illustrates the use of attachment measures in the context of a family court proceeding according to subsection 1666 German Civil Code. Risk assessment is carried out through direct observation of the quality of interaction between mother and ten months old infant as well as through evaluation of the attachment representations of both parent caregivers. Instruments used are the Strange Situation Test (to assess infant attachment), the CARE-Index (to assess parental sensitivity), the Adult Attachment Interview, and the Adult Attachment Projective (to assess parental attachment representations).
Lichte, F.E.; Meier, A.L.; Crock, J.G.
1987-01-01
A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.
NASA Astrophysics Data System (ADS)
Miller, D. J.; Zhang, Z.; Ackerman, A. S.; Platnick, S. E.; Cornet, C.
2016-12-01
A remote sensing cloud retrieval simulator, created by coupling an LES cloud model with vector radiative transfer (RT) models is the ideal framework for assessing cloud remote sensing techniques. This simulator serves as a tool for understanding bi-spectral and polarimetric retrievals by comparing them directly to LES cloud properties (retrieval closure comparison) and for comparing the retrieval techniques to one another. Our simulator utilizes the DHARMA LES [Ackerman et al., 2004] with cloud properties based on marine boundary layer (MBL) clouds observed during the DYCOMS-II and ATEX field campaigns. The cloud reflectances are produced by the vectorized RT models based on polarized doubling adding and monte carlo techniques (PDA, MCPOL). Retrievals are performed utilizing techniques as similar as possible to those implemented on their corresponding well known instruments; polarimetric retrievals are based on techniques implemented for polarimeters (POLDER, AirMSPI, and RSP) and bi-spectral retrievals are performed using the Nakajima-King LUT method utilized on a number of spectral instruments (MODIS and VIIRS). Retrieval comparisons focus on cloud droplet effective radius (re), effective variance (ve), and cloud optical thickness (τ). This work explores the sensitivities of these two retrieval techniques to various observation limitations, such as spatial resolution/cloud inhomogeneity, impact of 3D radiative effects, and angular resolution requirements. With future remote sensing missions like NASA's Aerosols/Clouds/Ecosystems (ACE) planning to feature advanced polarimetric instruments it is important to understand how these retrieval techniques compare to one another. The cloud retrieval simulator we've developed allows us to probe these important questions in a realistically relevant test bed.
Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes
NASA Technical Reports Server (NTRS)
Cataldo, Giuseppe; Hsieh, Wen-Ting; Huang, Wei-Chung; Moseley, S. Harvey; Stevenson, Thomas R.; Wollack, Edward J.
2014-01-01
The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (µ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.
NASA Technical Reports Server (NTRS)
Cataldo, Giuseppe
2014-01-01
The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.
Micro-Spec: an integrated direct-detection spectrometer for far-infrared space telescopes
NASA Astrophysics Data System (ADS)
Cataldo, Giuseppe; Hseih, Wen-Ting; Huang, Wei-Chung; Moseley, S. H.; Stevenson, Thomas R.; Wollack, Edward J.
2014-08-01
The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 μm wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a ~10 cm2 silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for μ-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. Two point designs with resolving power of 260 and 520 and an RMS phase error less than ~0:004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.
Mapping CHU9D Utility Scores from the PedsQLTM 4.0 SF-15.
Mpundu-Kaambwa, Christine; Chen, Gang; Russo, Remo; Stevens, Katherine; Petersen, Karin Dam; Ratcliffe, Julie
2017-04-01
The Pediatric Quality of Life Inventory™ 4.0 Short Form 15 Generic Core Scales (hereafter the PedsQL) and the Child Health Utility-9 Dimensions (CHU9D) are two generic instruments designed to measure health-related quality of life in children and adolescents in the general population and paediatric patient groups living with specific health conditions. Although the PedsQL is widely used among paediatric patient populations, presently it is not possible to directly use the scores from the instrument to calculate quality-adjusted life-years (QALYs) for application in economic evaluation because it produces summary scores which are not preference-based. This paper examines different econometric mapping techniques for estimating CHU9D utility scores from the PedsQL for the purpose of calculating QALYs for cost-utility analysis. The PedsQL and the CHU9D were completed by a community sample of 755 Australian adolescents aged 15-17 years. Seven regression models were estimated: ordinary least squares estimator, generalised linear model, robust MM estimator, multivariate factorial polynomial estimator, beta-binomial estimator, finite mixture model and multinomial logistic model. The mean absolute error (MAE) and the mean squared error (MSE) were used to assess predictive ability of the models. The MM estimator with stepwise-selected PedsQL dimension scores as explanatory variables had the best predictive accuracy using MAE and the equivalent beta-binomial model had the best predictive accuracy using MSE. Our mapping algorithm facilitates the estimation of health-state utilities for use within economic evaluations where only PedsQL data is available and is suitable for use in community-based adolescents aged 15-17 years. Applicability of the algorithm in younger populations should be assessed in further research.
Moon, Hye-Sung
2018-06-01
Using the da Vinci single-site platform, surgeons can perform more minimally invasive surgery. However, surgical challenges exist due to the limitations of single-site instrumental movements. To aid in the performance of successful robotic single-site hysterectomy, a new suturing technique using the current set of limited instruments is introduced in this study. New vaginal cuff suturing techniques have been used in 55 robotic single-site hysterectomies in our institute over the past 2 years. A needle driver approach utilizing screwing and advancing the needle driver in the correct direction at an increasing angle from the transverse cuff margin with dragging and formation of an adequate loop of thread was used when suturing the vaginal cuff. Using the new vaginal suturing techniques, easy and firm vaginal cuff closure with reduced operative time relative to previous hysterectomies was achieved. The new vaginal cuff suturing techniques may convince more surgeons to perform robotic single-site hysterectomies more frequently and with greater ease. Copyright © 2018. Published by Elsevier B.V.
A Neutron Diffractometer for a Long Pulsed Neutron Source
NASA Astrophysics Data System (ADS)
Sokol, Paul; Wang, Cailin
Long pulsed neutron sources are being actively developed as small university based sources and are being considered for the next generation of high powered sources, such as the European Neutron Source (ESS) and the Spallation Neutron Source (SNS) second target station. New instrumentation concepts will be required to effectively utilize the full spectrum of neutrons generated by these sources. Neutron diffractometers, which utilize time-of-flight (TOF) techniques for wavelength resolution, are particularly problematic. We describe an instrument for a long pulsed source that provides resolution comparable to that obtained on short pulsed sources without the need of long incident flight paths. We accomplish this by utilizing high speed choppers to impose a time structure on the spectrum of incident neutrons. By strategically positioning these choppers the response matrix assumes a convenient form that can be deconvoluted from the measured TOF spectrum to produce the diffraction pattern of the sample. We compare the performance of this instrument to other possible diffraction instruments that could be utilized on a long pulsed source.
Next-generation sequencing library construction on a surface.
Feng, Kuan; Costa, Justin; Edwards, Jeremy S
2018-05-30
Next-generation sequencing (NGS) has revolutionized almost all fields of biology, agriculture and medicine, and is widely utilized to analyse genetic variation. Over the past decade, the NGS pipeline has been steadily improved, and the entire process is currently relatively straightforward. However, NGS instrumentation still requires upfront library preparation, which can be a laborious process, requiring significant hands-on time. Herein, we present a simple but robust approach to streamline library preparation by utilizing surface bound transposases to construct DNA libraries directly on a flowcell surface. The surface bound transposases directly fragment genomic DNA while simultaneously attaching the library molecules to the flowcell. We sequenced and analysed a Drosophila genome library generated by this surface tagmentation approach, and we showed that our surface bound library quality was comparable to the quality of the library from a commercial kit. In addition to the time and cost savings, our approach does not require PCR amplification of the library, which eliminates potential problems associated with PCR duplicates. We described the first study to construct libraries directly on a flowcell. We believe our technique could be incorporated into the existing Illumina sequencing pipeline to simplify the workflow, reduce costs, and improve data quality.
SCExAO as a precursor to an ELT exoplanet direct imaging instrument
NASA Astrophysics Data System (ADS)
Jovanovic, Nemanja; Guyon, Olivier; Martinache, Frantz; Clergeon, Christophe; Singh, Garima; Vievard, Sebastien; Kudo, Tomoyuki; Garrel, Vincent; Norris, Barnaby; Tuthill, Peter; Stewart, Paul; Huby, Elsa; Perrin, Guy; Lacour, Sylvestre
2013-12-01
The Subaru Coronagraphic Extreme AO (SCExAO) instrument consists of a high performance Phase Induced Amplitude Apodisation (PIAA) coronagraph combined with an extreme Adaptive Optics (AO) system operating in the near-infrared (H band). The extreme AO system driven by the 2000 element deformable mirror will allow for Strehl ratios>90% to be achieved in the H-band when it goes closed loop. This makes the SCExAO instrument a powerful platform for high contrast imaging down to angular separations of the order of 1 lambda/D and an ideal testbed for exploring coronagraphic techniques for ELTs. In this paper we report on the recent progress in regards to the development of the instrument, which includes the addition of a visible bench that makes use of the light at shorter wavelengths not currently utilized by SCExAO and closing the loop on the tip/tilt wavefront sensor. We will also discuss several exciting guest instruments which will expand the capabilities of SCExAO over the next few years; namely CHARIS which is a integral field spectrograph as well as VAMPIRES, a visible aperture masking experiment based on polarimetric analysis of circumstellar disks. In addition we will elucidate the unique role extreme AO systems will play in enabling high precision radial velocity spectroscopy for the detection of small companions.
NASA Astrophysics Data System (ADS)
Gea, S.; Tjandra, S.; Joshua, J.; Wirjosentono, B.
2018-02-01
Coffee ground waste utilization for fluorescent carbon nanoparticles (F-CNPs) through soot oxidation with diluted HNO3 has been conducted. Soot was obtained through three different treatments to coffee ground waste; which was burned in furnaceat 550°C and 650°C and directly burned in a heat-proofcontainer. Then they were analyzed morphologically with Scanning Electron Microscope (SEM) instrument. Soot from direct burning indicated the optimum result where it has denser pores compared to other two soots. Soot obtained from direct burning was refluxed in diluted HNO3 for 12 hours to perform the oxidation. Yellowish brown supernatant was later observed which lead to green fluorescent under the UV light. F-CNPs characterization was done in Transmission Electron Microscopy, which showed that 7.4-23.4 nm of particle size were distributed.
Mars2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Do No Harm Test Series
NASA Technical Reports Server (NTRS)
Swanson, Gregory; Santos, Jose; White, Todd; Bruce, Walt; Kuhl, Chris; Wright, Henry
2017-01-01
A total of seventeen instrumented thermal sensor plugs, eight pressure transducers, two heat flux sensors, and one radiometer are planned to be utilized on the Mars 2020 missions thermal protection system (TPS) as part of the Mars Entry, Descent, and Landing Instrumentation II (MEDLI2) project. Of the MEDLI2 instrumentation, eleven instrumented thermal plugs and seven pressure transducers will be installed on the heatshield of the Mars 2020 vehicle while the rest will be installed on the backshell. The goal of the MEDLI2 instrumentation is to directly inform the large performance uncertainties that contribute to the design and validation of a Mars entry system. A better understanding of the entry environment and TPS performance could lead to reduced design margins enabling a greater payload mass-fraction and smaller landing ellipses. To prove that the MEDLI2 system will not degrade the performance of the Mars 2020 TPS, an Aerothermal Do No Harm (DNH) test series was designed and conducted. Like Mars 2020s predecessor, Mars Science Laboratory (MSL), the heatshield material will be Phenolic Impregnated Carbon Ablator (PICA); the Mars 2020 entry conditions are enveloped by the MSL design environments, therefore the development and qualification testing performed during MEDLI is sufficient to show that the similar MEDLI2 heatshield instrumentation will not degrade PICA performance. However, given that MEDLI did not include any backshell instrumentation, the MEDLI2 team was required to design and execute a DNH test series utilizing the backshell TPS material (SLA-561V) with the intended flight sensor suite. To meet the requirements handed down from Mars 2020, the MEDLI2 DNH test series emphasized the interaction between the MEDLI2 sensors and sensing locations with the surrounding backshell TPS and substrucutre. These interactions were characterized by performing environmental testing of four 12 by 12 test panels, which mimicked the construction of the backshell TPS and the integration of the MEDLI2 sensors as seen in Figure 1. The testing included thermal vacuumcycling, random vibration, shock, and arc jet testing. The test panels were fabricated by Lockheed Martin, establishing techniques that will be utilized during the Mars 2020 vehicle installation. Each test panel included one thermal sensor plug (two embedded thermocouples), one heat flux sensor, and multiple pressure port holes for evaluation.This presentation will discuss the planning and execution of the MEDLI2 DNH test series. Selected highlights and results of each environmental test will be presented, and lessons learned will be addressed that will feed forward into the planning for the MEDLI2 flight system certification testing.
14 CFR 23.1381 - Instrument lights.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...
14 CFR 23.1381 - Instrument lights.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...
14 CFR 23.1381 - Instrument lights.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...
14 CFR 23.1381 - Instrument lights.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...
14 CFR 23.1381 - Instrument lights.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Instrument lights. 23.1381 Section 23.1381... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Lights § 23.1381 Instrument lights. The instrument lights must— (a) Make each instrument and control easily readable and discernible...
Nguyen, Thi Anh Huong; Pham, Thi Ngoc Mai; Doan, Thi Tuoi; Ta, Thi Thao; Sáiz, Jorge; Nguyen, Thi Quynh Hoa; Hauser, Peter C; Mai, Thanh Duc
2014-09-19
An inexpensive, robust and easy to use portable capillary electrophoresis instrument with miniaturized high-voltage capacitively coupled contactless conductivity detection was developed. The system utilizes pneumatic operation to manipulate the solutions for all flushing steps. The different operations, i.e. capillary flushing, interface rinsing, and electrophoretic separation, are easily activated by turning an electronic switch. To allow the analysis of samples with limited available volume, and to render the construction less complicated compared to a computer-controlled counterpart, sample injection is carried out hydrodynamically directly from the sample vial into the capillary by manual syphoning. The system is a well performing solution where the financial means for the highly expensive commercial instruments are not available and where the in-house construction of a sophisticated automated instrument is not possible due to limited mechanical and electronic workshop facilities and software programming expertise. For demonstration, the system was employed successfully for the determination of some β-agonists, namely salbutamol, metoprolol and ractopamine down to 0.7ppm in pharmaceutical and pig-feed sample matrices in Vietnam. Copyright © 2014 Elsevier B.V. All rights reserved.
Van Berkel, Gary J.; Kertesz, Vilmos
2011-08-09
A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.
NASA Astrophysics Data System (ADS)
Adkins, Kevin; Elfajri, Oumnia; Sescu, Adrian
2016-11-01
Simulation and modeling have shown that wind farms have an impact on the near-surface atmospheric boundary layer (ABL) as turbulent wakes generated by the turbines enhance vertical mixing. These changes alter downstream atmospheric properties. With a large portion of wind farms hosted within an agricultural context, changes to the environment can potentially have secondary impacts such as to the productivity of crops. With the exception of a few observational data sets that focus on the impact to near-surface temperature, little to no observational evidence exists. These few studies also lack high spatial resolution due to their use of a limited number of meteorological towers or remote sensing techniques. This study utilizes an instrumented small unmanned aerial system (sUAS) to gather in-situ field measurements from two Midwest wind farms, focusing on the impact that large utility-scale wind turbines have on relative humidity. Results are also compared to numerical experiments conducted using large eddy simulation (LES). Wind turbines are found to differentially alter the relative humidity in the downstream, spanwise and vertical directions under a variety of atmospheric stability conditions.
Death education within health education: current status, future directions.
Crase, D
1981-12-01
A national survey was conducted among 205 university level divisions/departments of health education to determine the current status of death education courses within the health education field. Forty-nine college and university health educators currently teaching the course returned usable instruments. Death education receives the same credit, utilizes similar grading systems and is generally managed much like other academic courses. Since the discipline is in its infancy and many teachers are relatively unprepared, respondents called for greater quality control and improved professional preparation. Several concerns accompanying the growth of death education were identified.
NASA Astrophysics Data System (ADS)
Black, S.; Hynek, B. M.; Kierein-Young, K. S.; Avard, G.; Alvarado-Induni, G.
2015-12-01
Proper characterization of mineralogy is an essential part of geologic interpretation. This process becomes even more critical when attempting to interpret the history of a region remotely, via satellites and/or landed spacecraft. Orbiters and landed missions to Mars carry with them a wide range of analytical tools to aid in the interpretation of Mars' geologic history. However, many instruments make a single type of measurement (e.g., APXS: elemental chemistry; XRD: mineralogy), and multiple data sets must be utilized to develop a comprehensive understanding of a sample. Hydrothermal alteration products often exist in intimate mixtures, and vary widely across a site due to changing pH, temperature, and fluid/gas chemistries. These characteristics require that we develop a detailed understanding regarding the possible mineral mixtures that may exist, and their detectability in different instrument data sets. This comparative analysis study utilized several analytical methods on existing or planned Mars rovers (XRD Raman, LIBS, Mössbauer, and APXS) combined with additional characterization (thin section, VNIR, XRF, SEM-EMP) to develop a comprehensive suite of data for hydrothermal alteration products collected from Poás and Turrialba volcanoes in Costa Rica. Analyzing the same samples across a wide range of instruments allows for direct comparisons of results, and identification of instrumentation "blind spots." This provides insight into the ability of in-situ analyses to comprehensively characterize sites on Mars exhibiting putative hydrothermal characteristics, such as the silica and sulfate deposits at Gusev crater [eg: Squyres et al., 2008], as well as valuable information for future mission planning and data interpretation. References: Squyres et al. (2008), Detection of Silica-Rich Deposits on Mars, Science, 320, 1063-1067, doi:10.1126/science.1155429.
Liu, Zhao-Ying
2012-12-01
Metabolism studies play an important role at various stages of drug discovery and development. Liquid chromatography combined with mass spectrometry (LC/MS) has become a most powerful and widely used analytical tool for identifying drug metabolites. The suitability of different types of mass spectrometers for metabolite profiling differs widely, and therefore, the data quality and reliability of the results also depend on which instrumentation is used. As one of the latest LC/MS instrumentation designs, hybrid ion trap/time-of-flight MS coupled with LC (LC-IT-TOF-MS) has successfully integrated ease of operation, compatibility with LC flow rates and data-dependent MS(n) with high mass accuracy and mass resolving power. The MS(n) and accurate mass capabilities are routinely utilized to rapidly confirm the identification of expected metabolites or to elucidate the structures of uncommon or unexpected metabolites. These features make the LC-IT-TOF-MS a very powerful analytical tool for metabolite identification. This paper begins with a brief introduction to some basic principles and main properties of a hybrid IT-TOF instrument. Then, a general workflow for metabolite profiling using LC-IT-TOF-MS, starting from sample collection and preparation to final identification of the metabolite structures, is discussed in detail. The data extraction and mining techniques to find and confirm metabolites are discussed and illustrated with some examples. This paper is directed to readers with no prior experience with LC-IT-TOF-MS and will provide a broad understanding of the development and utility of this instrument for drug metabolism studies. Copyright © 2012 John Wiley & Sons, Ltd.
Polarimetric Decomposition Analysis of the Deepwater Horizon Oil Slick Using L-Band UAVSAR Data
NASA Technical Reports Server (NTRS)
Jones, Cathleen; Minchew, Brent; Holt, Benjamin
2011-01-01
We report here an analysis of the polarization dependence of L-band radar backscatter from the main slick of the Deepwater Horizon oil spill, with specific attention to the utility of polarimetric decomposition analysis for discrimination of oil from clean water and identification of variations in the oil characteristics. For this study we used data collected with the UAVSAR instrument from opposing look directions directly over the main oil slick. We find that both the Cloude-Pottier and Shannon entropy polarimetric decomposition methods offer promise for oil discrimination, with the Shannon entropy method yielding the same information as contained in the Cloude-Pottier entropy and averaged in tensity parameters, but with significantly less computational complexity
Mendelian randomization with Egger pleiotropy correction and weakly informative Bayesian priors.
Schmidt, A F; Dudbridge, F
2017-12-15
The MR-Egger (MRE) estimator has been proposed to correct for directional pleiotropic effects of genetic instruments in an instrumental variable (IV) analysis. The power of this method is considerably lower than that of conventional estimators, limiting its applicability. Here we propose a novel Bayesian implementation of the MR-Egger estimator (BMRE) and explore the utility of applying weakly informative priors on the intercept term (the pleiotropy estimate) to increase power of the IV (slope) estimate. This was a simulation study to compare the performance of different IV estimators. Scenarios differed in the presence of a causal effect, the presence of pleiotropy, the proportion of pleiotropic instruments and degree of 'Instrument Strength Independent of Direct Effect' (InSIDE) assumption violation. Based on empirical plasma urate data, we present an approach to elucidate a prior distribution for the amount of pleiotropy. A weakly informative prior on the intercept term increased power of the slope estimate while maintaining type 1 error rates close to the nominal value of 0.05. Under the InSIDE assumption, performance was unaffected by the presence or absence of pleiotropy. Violation of the InSIDE assumption biased all estimators, affecting the BMRE more than the MRE method. Depending on the prior distribution, the BMRE estimator has more power at the cost of an increased susceptibility to InSIDE assumption violations. As such the BMRE method is a compromise between the MRE and conventional IV estimators, and may be an especially useful approach to account for observed pleiotropy. © The Author 2017. Published by Oxford University Press on behalf of the International Epidemiological Association.
Direct Monitoring of Trace Atmospheric Species via Ion Trap Mass Spectrometry
NASA Technical Reports Server (NTRS)
Palmer, P. T.; Pearson, Richard; Saimonson, Jay D.; Wong, Carla M.; Lawless, James G. (Technical Monitor)
1994-01-01
There is an ever-increasing emphasis on the part of government agencies, academia, and industry on enhancing our understanding of atmospheric processes and assessing the impact of human activities on these processes. While issues such as the ozone hole and rising levels of greenhouse gases have received major attention. relatively little is known about the types, concentrations, sources, and sinks of hydrocarbons in the troposphere and stratosphere. Such information would be of tremendous utility in assessing the roles of various anthropogenic and biogenic processes on global carbon cycles. An ion trap mass spectrometer has been developed for monitoring trace levels of hydrocarbons in the atmosphere on NASA's DC-8 "flying laboratory". This aircraft is used to provide measurements in support of a number of "Mission to Planet Earth" activities and tropospheric chemistry experiments. In past missions, specific compounds have been monitored via highly specialized instrumentation, fast GO, or collection of whole air samples for subsequent ground-based analysis. The ion trap has several features. including small size. excellent sensitivity, and broad applicability, which make it highly atttrat:ive for atmospheric monitoring. The design of this instrument, its air sampling interface. and the various complications associated with aircraft-deployment will be described. Data showing the sensitivity of the instrument for detecting hydrocarbons at mixing ratios below one part-per-billion, and the use of MS/MS for direct, on-line, real-time monitoring will be presented.
Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.
Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M
2017-04-01
Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wideband Instrument for Snow Measurements (WISM)
NASA Technical Reports Server (NTRS)
Miranda, Felix A.; Lambert, Kevin M.; Romanofsky, Robert R.; Durham, Tim; Speed, Kerry; Lange, Robert; Olsen, Art; Smith, Brett; Taylor, Robert; Schmidt, Mark;
2016-01-01
This presentation discusses current efforts to develop a Wideband Instrument for Snow Measurements (WISM). The objective of the effort are as follows: to advance the utility of a wideband active and passive instrument (8-40 gigahertz) to support the snow science community; improve snow measurements through advanced calibration and expanded frequency of active and passive sensors; demonstrate science utility through airborne retrievals of snow water equivalent (SWE); and advance the technology readiness of broadband current sheet array (CSA) antenna technology for spaceflight applications.
Cross-cultural adaptation of instruments assessing breastfeeding determinants: a multi-step approach
2014-01-01
Background Cross-cultural adaptation is a necessary process to effectively use existing instruments in other cultural and language settings. The process of cross-culturally adapting, including translation, of existing instruments is considered a critical set to establishing a meaningful instrument for use in another setting. Using a multi-step approach is considered best practice in achieving cultural and semantic equivalence of the adapted version. We aimed to ensure the content validity of our instruments in the cultural context of KwaZulu-Natal, South Africa. Methods The Iowa Infant Feeding Attitudes Scale, Breastfeeding Self-Efficacy Scale-Short Form and additional items comprise our consolidated instrument, which was cross-culturally adapted utilizing a multi-step approach during August 2012. Cross-cultural adaptation was achieved through steps to maintain content validity and attain semantic equivalence in the target version. Specifically, Lynn’s recommendation to apply an item-level content validity index score was followed. The revised instrument was translated and back-translated. To ensure semantic equivalence, Brislin’s back-translation approach was utilized followed by the committee review to address any discrepancies that emerged from translation. Results Our consolidated instrument was adapted to be culturally relevant and translated to yield more reliable and valid results for use in our larger research study to measure infant feeding determinants effectively in our target cultural context. Conclusions Undertaking rigorous steps to effectively ensure cross-cultural adaptation increases our confidence that the conclusions we make based on our self-report instrument(s) will be stronger. In this way, our aim to achieve strong cross-cultural adaptation of our consolidated instruments was achieved while also providing a clear framework for other researchers choosing to utilize existing instruments for work in other cultural, geographic and population settings. PMID:25285151
The effectiveness of increased apical enlargement in reducing intracanal bacteria.
Card, Steven J; Sigurdsson, Asgeir; Orstavik, Dag; Trope, Martin
2002-11-01
It has been suggested that the apical portion of a root canal is not adequately disinfected by typical instrumentation regimens. The purpose of this study was to determine whether instrumentation to sizes larger than typically used would more effectively remove culturable bacteria from the canal. Forty patients with clinical and radiographic evidence of apical periodontitis were recruited from the endodontic clinic. Mandibular cuspids (n = 2), bicuspids (n = 11), and molars (mesial roots) (n = 27) were selected for the study. Bacterial sampling was performed upon access and after each of two consecutive instrumentations. The first instrumentation utilized 1% NaOCI and 0.04 taper ProFile rotary files. The cuspid and bicuspid canals were instrumented to a #8 size and the molar canals to a #7 size. The second instrumentation utilized LightSpeed files and 1% NaOCl irrigation for further enlargement of the apical third. Typically, molars were instrumented to size 60 and cuspid/bicuspid canals to size 80. Our findings show that 100% of the cuspid/bicuspid canals and 81.5% of the molar canals were rendered bacteria-free after the first instrumentation sizes. The molar results improved to 89% after the second instrumentation. Of the (59.3%) molar mesial canals without a clinically detectable communication, 93% were rendered bacteria-free with the first instrumentation. Using a Wilcoxon rank sum test, statistically significant differences (p < 0.0001) were found between the initial sample and the samples after the first and second instrumentations. The differences between the samples that followed the two instrumentation regimens were not significant (p = 0.0617). It is concluded that simple root canal systems (without multiple canal communications) may be rendered bacteria-free when preparation of this type is utilized.
Review of the Technology-Utilization Level of String Instrument Teachers
ERIC Educational Resources Information Center
Döger, Didem; Kiliç, Ilgim
2016-01-01
The purpose of this study is to determine the technology-utilization level of Fine Arts High School string instrument teachers. A pattern based on descriptive method has been used to conduct the researchers. Research data has been collected via literature review and questionnaire developed and prepared by the researcher. SPSS program has been…
Little Dog learning of tractive and compressive terrain characteristics
NASA Astrophysics Data System (ADS)
Digney, Bruce L.
2011-05-01
In recent years research into legged locomotion across extreme terrains has increased. Much of this work was done under the DARPA Learning Legged Locomotion program that utilized a standard Little Dog robot platform and prepared terrain test boards with known geometric data. While path planing using geometric information is necessary, acquiring and utilizing tractive and compressive terrain characteristics is equally important. This paper describes methods and results for learning tractive and compressive terrain characteristics with the Little Dog robot. The estimation of terrain traction and compressive/support capabilities using the mechanisms and movements of the robot rather than dedicated instruments is the goal of this research. The resulting characteristics may differ from those of standard tests, however they will be directly usable to the locomotion controllers given that they are obtained in the physical context of the actual robot and its actual movements. This paper elaborates on the methods used and presents results. Future work will develop better suited probabilistic models and interwave these methods with other purposeful actions of the robot to lessen the need for direct terrain probing actions.
Ganz, Michael L; Hansen, Brian Bekker; Valencia, Xavier; Strandberg-Larsen, Martin
2015-05-01
Economic evaluation is becoming more common and important as new biologic therapies for rheumatoid arthritis (RA) are developed. While much has been published about how to design cost-utility models for RA to conduct these evaluations, less has been written about the sources of data populating those models. The goal is to review the literature and to provide recommendations for future data collection efforts. This study reviewed RA cost-utility models published between January 2006 and February 2014 focusing on five key sources of data (health-related quality-of-life and utility, clinical outcomes, disease progression, course of treatment, and healthcare resource use and costs). It provided recommendations for collecting the appropriate data during clinical and other studies to support modeling of biologic treatments for RA. Twenty-four publications met the selection criteria. Almost all used two steps to convert clinical outcomes data to utilities rather than more direct methods; most did not use clinical outcomes measures that captured absolute levels of disease activity and physical functioning; one-third of them, in contrast with clinical reality, assumed zero disease progression for biologic-treated patients; little more than half evaluated courses of treatment reflecting guideline-based or actual clinical care; and healthcare resource use and cost data were often incomplete. Based on these findings, it is recommended that future studies collect clinical outcomes and health-related quality-of-life data using appropriate instruments that can convert directly to utilities; collect data on actual disease progression; be designed to capture real-world courses of treatment; and collect detailed data on a wide range of healthcare resources and costs.
Vargas, Emily; Becerril-Montekio, Victor; Gonzalez-Block, Miguel Ángel; Akweongo, Patricia; Hazel, Cynthia N A; Cuembelo, Maria de Fatima; Limbani, Felix; Bernardo, Wanderley; Muñoz, Fernando
2016-01-07
Striving to foster collaboration among countries suffering from maternal and child health (MCH) inequities, the MASCOT project mapped and analyzed the use of research in strategies tackling them in 11 low- and middle-income countries. This article aims to present the way in which research influenced MCH policies and programs in six of these countries - three in Africa and three in Latin America. Qualitative research using a thematic synthesis narrative process was used to identify and describe who is producing what kind of research, how research is funded, how inequities are approached by research and policies, the countries' research capacities, and the type of evidence base that MCH policies and programs use. Four tools were designed for these purposes: an online survey for researchers, a semi-structured interview with decision makers, and two content analysis guides: one for policy and programs documents and one for scientific articles. Three modalities of research utilization were observed in the strategies tackling MCH inequities in the six included countries - instrumental, conceptual and symbolic. Instrumental utilization directly relates the formulation and contents of the strategies with research results, and is the least used within the analyzed policies and programs. Even though research is considered as an important input to support decision making and most of the analyzed countries count five or six relevant MCH research initiatives, in most cases, the actual impact of research is not clearly identifiable. While MCH research is increasing in low- and middle-income countries, the impact of its outcomes on policy formulation is low. We did not identify a direct relationship between the nature of the financial support organizations and the kind of evidence utilization within the policy process. There is still a visible gap between researchers and policymakers regarding their different intentions to link evidence and decision making processes.
Hayward, Denyse V; Ritter, Kathryn; Mousavi, Amin; Vatanapour, Shabnam
2016-01-01
To report on the Phase 2 development of the Sound Access Parent Outcomes Instrument (SAPOI), a new instrument focused on formalizing outcomes that parents of children with severe multiple disabilities (SMD) who use amplification prioritize as important. Phase 2 of this project involved item selection and refinement of the SAPOI based on (a) Phase 1 study participant input, (b) clinical specialist feedback, and (c) test-retest instrument reliability. Phase 1 participant responses were utilized to construct a draft version of the SAPOI. Next, clinical specialists examined the instrument for content validity and utility and instrument reliability was examined through a test-retest process with parents of children with SMD. The draft SAPOI was constructed based on Phase 1 participant input. Clinical specialists supported content validity and utility of the instrument and the inclusion of 19 additional items across four categories, namely Child Affect, Child Interaction, Parent Well-being, and Child's Device Use. The SAPOI was completed twice at one-month intervals by parents of children with SMD to examine instrument reliability across the four categories (Child Affect, Child Interaction, Parent Well-being, and Child's Device Use). Instrument reliability was strong-to-excellent across all four sections. The SAPOI shows promise as a much-needed addition to the assessment battery currently used for children with SMD who use cochlear implants and hearing aids. It provides valuable information regarding outcomes resulting from access to sound in this population that currently used assessments do not identify.
Low-cost coding of directivity information for the recording of musical instruments
NASA Astrophysics Data System (ADS)
Braasch, Jonas; Martens, William L.; Woszczyk, Wieslaw
2004-05-01
Most musical instruments radiate sound according to characteristic spatial directivity patterns. These patterns are usually not only strongly frequency dependent, but also time-variant functions of various parameters of the instrument, such as pitch and the playing technique applied (e.g., plucking versus bowing of string instruments). To capture the directivity information when recording an instrument, Warusfel and Misdariis (2001) proposed to record an instrument using four channels, one for the monopole and the others for three orthogonal dipole parts. In the new recording setup presented here, it is proposed to store one channel at a high sampling frequency, along with directivity information that is updated only every few milliseconds. Taking the binaural sluggishness of the human auditory system into account in this way provides a low-cost coding scheme for subsequent reproduction of time-variant directivity patterns.
Bi-directional four quadrant (BDQ4) power converter development
NASA Technical Reports Server (NTRS)
Schwarz, F. C.
1979-01-01
The feasibility for implementation of a concept for direct ac/dc multikilowatt power conversion with bidirectional transfer of energy was investigated. A 10 kHz current carrier was derived directly from a common 60 Hz three phase power system. This carrier was modulated to remove the 360 Hz ripple, inherent in the three phase power supply and then demodulated and processed by a high frequency filter. The resulting dc power was then supplied to a load. The process was implemented without the use of low frequency transformers and filters. This power conversion processes was reversible and can operate in the four quadrants as viewed from any of the two of the converter's ports. Areas of application include: power systems on air and spacecraft; terrestrial traction; integration of solar and wind powered systems with utility networks; HVDC; asynchronous coupling of polyphase networks; heat treatment; industrial machine drives; and power supplies for any use including instrumentation.
Control volume based hydrocephalus research; analysis of human data
NASA Astrophysics Data System (ADS)
Cohen, Benjamin; Wei, Timothy; Voorhees, Abram; Madsen, Joseph; Anor, Tomer
2010-11-01
Hydrocephalus is a neuropathophysiological disorder primarily diagnosed by increased cerebrospinal fluid volume and pressure within the brain. To date, utilization of clinical measurements have been limited to understanding of the relative amplitude and timing of flow, volume and pressure waveforms; qualitative approaches without a clear framework for meaningful quantitative comparison. Pressure volume models and electric circuit analogs enforce volume conservation principles in terms of pressure. Control volume analysis, through the integral mass and momentum conservation equations, ensures that pressure and volume are accounted for using first principles fluid physics. This approach is able to directly incorporate the diverse measurements obtained by clinicians into a simple, direct and robust mechanics based framework. Clinical data obtained for analysis are discussed along with data processing techniques used to extract terms in the conservation equation. Control volume analysis provides a non-invasive, physics-based approach to extracting pressure information from magnetic resonance velocity data that cannot be measured directly by pressure instrumentation.
Optical Testing Using Portable Laser Coordinate Measuring Instruments
NASA Technical Reports Server (NTRS)
Khreishi, Manal; Ohl, Raymond G.; Mclean, Kyle F.; Hadjimichael, Theodore J.; Hayden, Joseph E.
2017-01-01
High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LR's ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikon's MV-224/350 LR and Leica's Absolute Tracker AT401/402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the "direct and through" (D&T), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the D&T shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.
Sterilization of instruments in solar ovens.
Jørgensen, A F; Nøhr, K; Boisen, F; Nøhr, J
2002-01-01
The sterilization of instruments in rural health clinics in less developed countries is an increasing problem as chemical methods can no longer be recommended and fuel wood is becoming increasingly scarce. It seems obvious, therefore, to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. It was tested by physical, chemical and microbiological methods and, after successful testing, installed in a rural clinic. The oven was able to generate temperatures above 180 degrees C. On days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization. The chemical indicators, Browne's tubes type 3 and 5, also changed colour. It was difficult to reach the right value for the sterilization effect during months with a low sun position. A moveable oven, or two ovens, must be installed to solve this problem. The solar oven has proven to be a realistic method for the sterilization of instruments. The solar oven is easy to make and use. It saves fuel and can be used in most tropical areas.
Optical Testing Using Portable Laser Coordinate Measuring Instruments
NASA Technical Reports Server (NTRS)
Khreishi, M.; Ohl, R.; Mclean, K.; Hadjimichael, T.; Hayden, J.
2017-01-01
High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.
An Imaging Calorimeter for Access-Concept Study
NASA Technical Reports Server (NTRS)
Parnell, T. A.; Adams, James H.; Binns, R. W.; Christl, M. J.; Derrickson, J. H.; Fountain, W. F.; Howell, L. W.; Gregory, J. C.; Hink, P. L.; Israel, M. H.;
2001-01-01
A mission concept study to define the "Advanced Cosmic-ray Composition Experiment for Space Station (ACCESS)" was sponsored by the National Aeronautics and Space Administration (NASA). The ACCESS instrument complement contains a transition radiation detector and an ionization calorimeter to measure tile spectrum of protons, helium, and heavier nuclei up to approximately 10(exp 15) eV to search for the limit of S/N shock wave acceleration, or evidence for other explanations of the spectra. Several calorimeter configurations have been studied, including the "baseline" totally active bismuth germanate instrument and sampling calorimeters utilizing various detectors. The Imaging Calorimeter for ACCESS (ICA) concept comprises a carbon target and a calorimeter using a high atomic number absorber sampled approximately each radiation length (rl) by thin scintillating fiber (SCIFI) detectors. The main features and options of the ICA instrument configuration are described in this paper. Since direct calibration is not possible over most of the energy range, the best approach must be decided from simulations of calorimeter performance extrapolated from CERN calibrations at 0.375 TeV. This paper presents results from the ICA simulations study.
Instruments to assess stigmatization in dermatology.
Dimitrov, Dimitre; Szepietowski, Jacek C
2017-11-03
Stigmatization is the assignment of negative perceptions to an individual because of a perceived difference from the population at large. Skin conditions are frequently the reason of social rejection with a consequent negative influence on the personal and social life of patients. The aim of the current study was to review the available instruments that can be successfully utilized to measure the stigmatization level among dermatological patients. We performed our search on PubMed up to November 2016 and utilized combinations of key phrases containing such words as stigmatization, skin, dermatology, names of various skin conditions (psoriasis, vitiligo, acne, etc.), measurement. The search found a considerable number of articles - 548. After filtering them through a precise selection process, 58 articles remained. We concentrated only on the methodological aspects to assess stigmatization in various dermatoses. The review ascertained that there exist numerous instruments in the form of questionnaires. They were utilized in various researches in order to assess the stigmatization level in patients with skin problems. We divided them into two main groups: dermatology specific instruments (6 questionnaires) and dermatosis/disease specific ones (8 questionnaires). It is recommended to use dermatology-specific instruments to compare the stigmatization level in various skin conditions. They can be utilized as well as a first line tools to study the feeling of stigmatization in specific skin diseases; however, where it is possible, they should be supplemented with the disease-specific instrument for deeper analysis of both qualities of life and stigmatization.
Regional Instrumentation Centers.
ERIC Educational Resources Information Center
Cromie, William J.
1980-01-01
Focuses on the activities of regional instrumentation centers that utilize the state-of-the-art instruments and methodology in basic scientific research. The emphasis is on the centers involved in mass spectroscopy, magnetic resonance spectroscopy, lasers, and accelerators. (SA)
Gyroscopic Instruments for Instrument Flying
NASA Technical Reports Server (NTRS)
Brombacher, W G; Trent, W C
1938-01-01
The gyroscopic instruments commonly used in instrument flying in the United States are the turn indicator, the directional gyro, the gyromagnetic compass, the gyroscopic horizon, and the automatic pilot. These instruments are described. Performance data and the method of testing in the laboratory are given for the turn indicator, the directional gyro, and the gyroscopic horizon. Apparatus for driving the instruments is discussed.
Normal incidence X-ray mirror for chemical microanalysis
Carr, Martin J.; Romig, Jr., Alton D.
1990-01-01
A non-planar, focusing mirror, to be utilized in both electron column instruments and micro-x-ray fluorescence instruments for performing chemical microanalysis on a sample, comprises a concave, generally spherical base substrate and a predetermined number of alternating layers of high atomic number material and low atomic number material contiguously formed on the base substrate. The thickness of each layer is an integral multiple of the wavelength being reflected and may vary non-uniformly according to a predetermined design. The chemical analytical instruments in which the mirror is used also include a predetermined energy source for directing energy onto the sample and a detector for receiving and detecting the x-rays emitted from the sample; the non-planar mirror is located between the sample and detector and collects the x-rays emitted from the sample at a large solid angle and focuses the collected x-rays to the sample. For electron column instruments, the wavelengths of interest lie above 1.5 nm, while for x-ray fluorescence instruments, the range of interest is below 0.2 nm. Also, x-ray fluorescence instruments include an additional non-planar focusing mirror, formed in the same manner as the previously described m The invention described herein was made in the performance of work under contract with the Department of Energy, Contract No. DE-AC04-76DP00789, and the United States Government has rights in the invention pursuant to this contract.
NASA Astrophysics Data System (ADS)
Mihn, Byeong-Hee; Lee, Ki-Won; Ahn, Young Sook; Lee, Yong Sam
2015-03-01
During the reign of King Sejong (世宗, 1418-1450) in the Joseon Dynasty, there were lots of astronomical instruments, including miniaturized ones. Those instruments utilized the technical know-how acquired through building contemporary astronomical instruments previously developed in the Song(宋), Jin(金), and Yuan(元) dynasties of China. In those days, many astronomical instruments had circles, rings, and spheres carved with a scale of 365.25, 100, and 24 parts, respectively, on their circumference. These were called the celestial-circumference degree, hundred-interval (Baekgak), and 24 direction, respectively. These scales are marked by the angular distance, not by the angle. Therefore, these circles, rings, and spheres had to be optimized in size to accomodate proper scales. Assuming that the scale system is composed of integer multiples of unit length, we studied the sizes of circles by referring to old articles and investigating existing artifacts. We discovered that the star chart of Cheonsang yeolcha bunyajido was drawn with a royal standard ruler (周尺) based on the unit length of 207 mm. Interestingly, its circumference was marked by the unit scale of 3 puns per 1 du (or degree) like Honsang (a celestial globe). We also found that Hyeonju ilgu (a equatorial sundial) has a Baekgak disk on a scale of 1 pun per 1 gak (that is an interval of time similar to a quarter). This study contributes to the analysis of specifications of numerous circular elements from old Korean astronomical instruments.
Heiderscheit, Annie; Breckenridge, Stephanie J; Chlan, Linda L; Savik, Kay
2014-01-01
Mechanical ventilation (MV) is a life-saving measure and supportive modality utilized to treat patients experiencing respiratory failure. Patients experience pain, discomfort, and anxiety as a result of being mechanically ventilated. Music listening is a non-pharmacological intervention used to manage these psychophysiological symptoms associated with mechanical ventilation. The purpose of this secondary analysis was to examine music preferences of 107 MV patients enrolled in a randomized clinical trial that implemented a patient-directed music listening protocol to help manage the psychophysiological symptom of anxiety. Music data presented includes the music genres and instrumentation patients identified as their preferred music. Genres preferred include: classical, jazz, rock, country, and oldies. Instrumentation preferred include: piano, voice, guitar, music with nature sounds, and orchestral music. Analysis of three patients' preferred music received throughout the course of the study is illustrated to demonstrate the complexity of assessing MV patients and the need for an ongoing assessment process.
Tissue modification with feedback: the smart scalpel
NASA Astrophysics Data System (ADS)
Sebern, Elizabeth L.; Brenan, Colin J. H.; Anderson, R. Rox; Hunter, Ian W.
1998-10-01
While feedback control is widespread throughout many engineering fields, there are almost no examples of surgical instruments that utilize a real-time detection and intervention strategy. This concept of closed loop feedback can be applied to the development of autonomous or semi- autonomous minimally invasive robotic surgical systems for efficient excision or modification of diseased tissue. Spatially localized regions of the tissue are first probed to distinguish pathological from healthy tissue based on differences in histochemical and morphological properties. Energy is directed to only the diseased tissue, minimizing collateral damage by leaving the adjacent healthy tissue intact. Continuous monitoring determines treatment effectiveness and, if needed, enables real-time treatment modifications to produce optimal therapeutic outcomes. The present embodiment of this general concept is a microsurgical instrument we call the Smart Scalpel, designed to treat skin angiodysplasias such as port wine stains. Other potential Smart Scalpel applications include psoriasis treatment and early skin cancer detection and intervention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reiner, E.J.; Schellenberg, D.H.; Taguchi, V.Y.
1991-01-01
A mass spectrometry/mass spectrometry-multiple reaction monitoring (MS/MS-MRM) technique for the analysis of all tetra- through octachlorinated dibenzo-p-dioxins (Cl{sub x}DD, x = 4-8) and dibenzofurans (Cl{sub x}DF, x = 4-8) has been developed at the Ministry of the Environment (MOE) utilizing a triple quadrupole mass spectrometer. Optimization of instrumental parameters using the analyte of interest in a direct insertion probe (DIP) resulted in sensitivities approaching those obtainable by high-resolution mass spectrometric (HRMS) methods. All congeners of dioxins and furans were detected in the femtogram range. Results on selected samples indicated that for some matrices, fewer chemical interferences were observed by MS/MSmore » than by HRMS. The technique used to optimize the instrument for chlorinated dibenzo-p-dioxins (CDDs) and chlorinated dibenzofurans (CDFs) analysis is adaptable to other analytes.« less
NASA Astrophysics Data System (ADS)
Ferkinhoff, Carl
2014-07-01
There have been several exciting developments in the technologies commonly used n in the hardware hacking community. Advances in low cost additive-manufacturing processes (i.e. 3D-printers) and the development of openhardware projects, which have produced inexpensive and easily programmable micro-controllers and micro-computers (i.e. Arduino and Raspberry Pi) have opened a new door for individuals seeking to make their own devices. Here we describe the potential for these technologies to reduce costs in construction and development of submillimeter/millimeter astronomical instrumentation. Specifically we have begun a program to measure the optical properties of the custom plastics used in 3D-printers as well as the printer accuracy and resolution to assess the feasibility of directly printing sub- /millimeter transmissive optics. We will also discuss low cost designs for cryogenic temperature measurement and control utilizing Arduino and Raspberry Pi.
Screening materials with the XIA UltraLo alpha particle counter at Southern Methodist University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakib, M. Z.; Cooley, J.; Kara, B.
2013-08-08
Southern Methodist University houses one of five existing commercially available UltraLo 1800 production model alpha counters made by XIA LLC. The instrument has an electron drift chamber with a 707 cm{sup 2} or 1800 cm{sup 2} counting region which is determined by selecting the inner electrode size. The SMU team operating this device is part of the SuperCDMS screening working group, and uses the alpha counter to study the background rates from the decay of radon in materials used to construct the SuperCDMS experiment. We have studied four acrylic samples obtained from the MiniCLEAN direct dark matter search with themore » XIA instrument demonstrating its utility in low background experiments by investigating the plate-out of {sup 210}Pb and comparing the effectiveness of cleaning procedures in removing {sup 222}Rn progenies from the samples.« less
Research pressure instrumentation for NASA Space Shuttle main engine, modification no. 5
NASA Technical Reports Server (NTRS)
Anderson, P. J.; Nussbaum, P.; Gustafson, G.
1984-01-01
The purpose of Modification No. 5 of this contract is to expand the scope of work (Task C) of this research study effort to develop pressure instrumentation for the SSME. The objective of this contract (Task C) is to direct Honeywell's Solid State Electronics Division's (SSED) extensive experience and expertise in solid state sensor technology to develop prototype pressure transducers which are targeted to meet the SSME performance design goals and to fabricate, test and deliver a total of 10 prototype units. SSED's basic approach is to effectively utilize the many advantages of silicon piezoresistive strain sensing technology to achieve the objectives of advanced state-of-the-art pressure sensors in terms of reliability, accuracy and ease of manufacture. More specifically, integration of multiple functions on a single chip is the key attribute of this technology which will be exploited during this research study.
Music preferences of mechanically ventilated patients participating in a randomized controlled trial
Heiderscheit, Annie; Breckenridge, Stephanie J.; Chlan, Linda L.; Savik, Kay
2014-01-01
Mechanical ventilation (MV) is a life-saving measure and supportive modality utilized to treat patients experiencing respiratory failure. Patients experience pain, discomfort, and anxiety as a result of being mechanically ventilated. Music listening is a non-pharmacological intervention used to manage these psychophysiological symptoms associated with mechanical ventilation. The purpose of this secondary analysis was to examine music preferences of 107 MV patients enrolled in a randomized clinical trial that implemented a patient-directed music listening protocol to help manage the psychophysiological symptom of anxiety. Music data presented includes the music genres and instrumentation patients identified as their preferred music. Genres preferred include: classical, jazz, rock, country, and oldies. Instrumentation preferred include: piano, voice, guitar, music with nature sounds, and orchestral music. Analysis of three patients’ preferred music received throughout the course of the study is illustrated to demonstrate the complexity of assessing MV patients and the need for an ongoing assessment process. PMID:25574992
Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J
2018-01-01
Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.
NASA Astrophysics Data System (ADS)
Ryan, James M.; Bancroft, Christopher; Bloser, Peter; Bravar, Ulisse; Fourguette, Dominique; Frost, Colin; Larocque, Liane; McConnell, Mark L.; Legere, Jason; Pavlich, Jane; Ritter, Greg; Wassick, Greg; Wood, Joshua; Woolf, Richard
2010-08-01
We have developed, fabricated and tested a prototype imaging neutron spectrometer designed for real-time neutron source location and identification. Real-time detection and identification is important for locating materials. These materials, specifically uranium and transuranics, emit neutrons via spontaneous or induced fission. Unlike other forms of radiation (e.g. gamma rays), penetrating neutron emission is very uncommon. The instrument detects these neutrons, constructs images of the emission pattern, and reports the neutron spectrum. The device will be useful for security and proliferation deterrence, as well as for nuclear waste characterization and monitoring. The instrument is optimized for imaging and spectroscopy in the 1-20 MeV range. The detection principle is based upon multiple elastic neutron-proton scatters in organic scintillator. Two detector panel layers are utilized. By measuring the recoil proton and scattered neutron locations and energies, the direction and energy spectrum of the incident neutrons can be determined and discrete and extended sources identified. Event reconstruction yields an image of the source and its location. The hardware is low power, low mass, and rugged. Its modular design allows the user to combine multiple units for increased sensitivity. We will report the results of laboratory testing of the instrument, including exposure to a calibrated Cf-252 source. Instrument parameters include energy and angular resolution, gamma rejection, minimum source identification distances and times, and projected effective area for a fully populated instrument.
Hicks, Patricia J; Margolis, Melissa; Poynter, Sue E; Chaffinch, Christa; Tenney-Soeiro, Rebecca; Turner, Teri L; Waggoner-Fountain, Linda; Lockridge, Robin; Clyman, Stephen G; Schwartz, Alan
2016-05-01
To report on the development of content and user feedback regarding the assessment process and utility of the workplace-based assessment instruments of the Pediatrics Milestones Assessment Pilot (PMAP). One multisource feedback instrument and two structured clinical observation instruments were developed and refined by experts in pediatrics and assessment to provide evidence for nine competencies based on the Pediatrics Milestones (PMs) and chosen to inform residency program faculty decisions about learners' readiness to serve as pediatric interns in the inpatient setting. During the 2012-2013 PMAP study, 18 U.S. pediatric residency programs enrolled interns and subinterns. Faculty, residents, nurses, and other observers used the instruments to assess learner performance through direct observation during a one-month rotation. At the end of the rotation, data were aggregated for each learner, milestone levels were assigned using a milestone classification form, and feedback was provided to learners. Learners and site leads were surveyed and/or interviewed about their experience as participants. Across the sites, 2,338 instruments assessing 239 learners were completed by 630 unique observers. Regarding end-of-rotation feedback, 93% of learners (128/137) agreed the assessments and feedback "helped me understand how those with whom I work perceive my performance," and 85% (117/137) agreed they were "useful for constructing future goals or identifying a developmental path." Site leads identified several benefits and challenges to the assessment process. PM-based instruments used in workplace-based assessment provide a meaningful and acceptable approach to collecting evidence of learner competency development. Learners valued feedback provided by PM-based assessment.
The influence of the magnetic field on running penumbral waves in the solar chromosphere
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jess, D. B.; Reznikova, V. E.; Van Doorsselaere, T.
2013-12-20
We use images of high spatial and temporal resolution, obtained using both ground- and space-based instrumentation, to investigate the role magnetic field inclination angles play in the propagation characteristics of running penumbral waves in the solar chromosphere. Analysis of a near-circular sunspot, close to the center of the solar disk, reveals a smooth rise in oscillatory period as a function of distance from the umbral barycenter. However, in one directional quadrant, corresponding to the north direction, a pronounced kink in the period-distance diagram is found. Utilizing a combination of the inversion of magnetic Stokes vectors and force-free field extrapolations, wemore » attribute this behavior to the cut-off frequency imposed by the magnetic field geometry in this location. A rapid, localized inclination of the magnetic field lines in the north direction results in a faster increase in the dominant periodicity due to an accelerated reduction in the cut-off frequency. For the first time, we reveal how the spatial distribution of dominant wave periods, obtained with one of the highest resolution solar instruments currently available, directly reflects the magnetic geometry of the underlying sunspot, thus opening up a wealth of possibilities in future magnetohydrodynamic seismology studies. In addition, the intrinsic relationships we find between the underlying magnetic field geometries connecting the photosphere to the chromosphere, and the characteristics of running penumbral waves observed in the upper chromosphere, directly supports the interpretation that running penumbral wave phenomena are the chromospheric signature of upwardly propagating magneto-acoustic waves generated in the photosphere.« less
Gustavsson, A; Jonsson, L; Rapp, T; Reynish, E; Ousset, P J; Andrieu, S; Cantet, C; Winblad, B; Vellas, B; Wimo, A
2010-10-01
This study aimed to estimate the costs of formal and informal care of patients with Alzheimer's disease, to compare care costs across European countries and identify potential differences in cost patterns between countries and regions. The ICTUS study is a prospective, naturalistic observational study conducted in specialised memory clinics in 12 European countries. In total, 1385 patients diagnosed with Alzheimer's disease were enrolled at baseline. All subjects had a reliable informant (primary caregiver) and informed consent was obtained from patients or their primary caregiver. Resource utilization data was captured with the RUD Lite (Resource Utilization in Dementia) instrument and caregiver burden with the Zarit Burden Interview (ZBI). Patient disease severity was measured with the Mini-Mental State Examination (MMSE), Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-cog), Katz´ index (PADL), Instrumental activities of daily living (IADL) scale and Neuropsychiatric inventory (NPI). The mean annual cost of care per patient was estimated to €7,820 (95% CI: €7,194-€8,446), whereof 54% were costs of informal care, 16% direct medical costs and 30% community care costs. There were substantial differences in total resource utilization and also in the balance between formal and informal care between Northern, Western and Southern Europe. PADL scores were strongly associated with formal care costs while IADL scores correlated strongly with informal care costs. Costs of Alzheimer's disease are high across European countries. Activities of daily living is an important determinant of care costs. Formal care service use is lower and informal care higher in Southern Europe compared to Western and Northern Europe. Differences in resource utilization patterns are important to consider in international studies of dementia care costs as well as in economic evaluations of new treatments for dementia.
Kling, Maximilian; Seyring, Nicole; Tzanova, Polia
2016-09-01
Economic instruments provide significant potential for countries with low municipal waste management performance in decreasing landfill rates and increasing recycling rates for municipal waste. In this research, strengths and weaknesses of landfill tax, pay-as-you-throw charging systems, deposit-refund systems and extended producer responsibility schemes are compared, focusing on conditions in countries with low waste management performance. In order to prioritise instruments for implementation in these countries, the analytic hierarchy process is applied using results of a literature review as input for the comparison. The assessment reveals that pay-as-you-throw is the most preferable instrument when utility-related criteria are regarded (wb = 0.35; analytic hierarchy process distributive mode; absolute comparison) mainly owing to its waste prevention effect, closely followed by landfill tax (wb = 0.32). Deposit-refund systems (wb = 0.17) and extended producer responsibility (wb = 0.16) rank third and fourth, with marginal differences owing to their similar nature. When cost-related criteria are additionally included in the comparison, landfill tax seems to provide the highest utility-cost ratio. Data from literature concerning cost (contrary to utility-related criteria) is currently not sufficiently available for a robust ranking according to the utility-cost ratio. In general, the analytic hierarchy process is seen as a suitable method for assessing economic instruments in waste management. Independent from the chosen analytic hierarchy process mode, results provide valuable indications for policy-makers on the application of economic instruments, as well as on their specific strengths and weaknesses. Nevertheless, the instruments need to be put in the country-specific context along with the results of this analytic hierarchy process application before practical decisions are made. © The Author(s) 2016.
2010 CEOS Field Reflectance Intercomparisons Lessons Learned
NASA Technical Reports Server (NTRS)
Thome, Kurtis; Fox, Nigel
2011-01-01
This paper summarizes lessons learned from the 2009 and 2010 joint field campaigns to Tuz Golu, Turkey. Emphasis is placed on the 2010 campaign related to understanding the equipment and measurement protocols, processing schemes, and traceability to SI quantities. Participants in both 2009 and 2010 used an array of measurement approaches to determine surface reflectance. One lesson learned is that even with all of the differences in collection between groups, the differences in reflectance are currently dominated by instrumental artifacts including knowledge of the white reference. Processing methodology plays a limited role once the bi-directional reflectance of the white reference is used rather than a hemispheric-directional value. The lack of a basic set of measurement protocols, or best practices, limits a group s ability to ensure SI traceability and the development of proper error budgets. Finally, rigorous attention to sampling methodology and its impact on instrument behavior is needed. The results of the 2009 and 2010 joint campaigns clearly demonstrate both the need and utility of such campaigns and such comparisons must continue in the future to ensure a coherent set of data that can span multiple sensor types and multiple decades.
Monitoring industrial wastewater by online GC-MS with direct aqueous injection.
Wortberg, M; Ziemer, W; Kugel, M; Müller, H; Neu, H-J
2006-03-01
An online GC-MS-system for automated monitoring of crude wastewater at a complex chemical production site is presented. The modular system is, in principal, based on commercial equipment, but utilizes a special, two-stage injector, which consists of a splitless vaporization chamber on top of a PTV injector filled with Tenax. This set-up enables direct injection of wastewater. Almost 140 volatile and semi-volatile compounds are calibrated down to 1 mg L(-1), which is sufficient for analysis of the influent of the wastewater-treatment plant. Two instruments analyze alternately, every 20 min, and the instrument cycle time is 40 min. The quantitative results are transferred to a database which is connected to a process-control system. Depending on the nature and concentration of a compound, an alarm can be generated and the wastewater stream can be diverted into an "off spec tank" if necessary. The GC-MS-system operates quasi-continuously with a system availability >98%. Data quality is automatically controlled in each run and by daily analysis of a quality-control sample. The development of a novel stacked PTV-PTV injector design to expand the range of analytes to selected basic compounds is described.
Satapathy, Sujata; Choudhary, Vandana; Sagar, Rajesh
2017-02-01
Absence of visible physical symptoms and limited capacity to express trauma directly, pose significant challenges in assessment of its exact nature of trauma and its correlates in child sexual abuse. There are numerous assessment tools however, deciding upon the appropriateness is often challenging in Asian socio-cultural and health care set up. A review would provide a ready reference to the practioner regarding the exact clinically utility of the tools and also would guide them in the direction of culture specific modifications. Computerized databases namely Medline, PsycINFO, Health and Psychosocial Instruments, and Social Sciences Citation Index were used. 52 scales were obtained and analysed in terms of scale characteristics, reference to theory and DSM, and cultural competency. Despite of a wide variety of methods, and newer instruments, many of the traditionally used techniques of child's internal thinking and emotional assessment appear outdated while reviewing the recent theories of CSA related psychological trauma. An integrated format, incroporating child-parent-clinicain rating, with multiple domain speciafic items and verbal and non-verbal tasks, is the current need in the Asian region. Copyright © 2016 Elsevier B.V. All rights reserved.
Sample preparation of metal alloys by electric discharge machining
NASA Technical Reports Server (NTRS)
Chapman, G. B., II; Gordon, W. A.
1976-01-01
Electric discharge machining was investigated as a noncontaminating method of comminuting alloys for subsequent chemical analysis. Particulate dispersions in water were produced from bulk alloys at a rate of about 5 mg/min by using a commercially available machining instrument. The utility of this approach was demonstrated by results obtained when acidified dispersions were substituted for true acid solutions in an established spectrochemical method. The analysis results were not significantly different for the two sample forms. Particle size measurements and preliminary results from other spectrochemical methods which require direct aspiration of liquid into flame or plasma sources are reported.
Rapid multispectral cw multiplexing technique for photon migration measurements
NASA Astrophysics Data System (ADS)
Siegel, Andrew M.; Boas, David A.
2001-06-01
A discussion of photon migration will introduce both some fundamental limitations and practical concerns which directly affect the design and construction of DOT instrumentation. The utility of four different multiplexing schemes will be discussed and then contrasted in light of these concerns. The relative merits of each scheme will be used to determine which measurements they are best suited for, given some of the realistic technical, legal, and practical issues common to the medical research community. Within this context, the unique advantages offered by a variant of time-division multiplexing; Pulse-TDM, will be introduced and explained.
NASA Technical Reports Server (NTRS)
Haubold, Hans J. (Editor); Torres, Sergio (Editor)
1994-01-01
The conference primarily covered astrophysical and astronomical topics on stellar and solar modeling and processes, high magnetic field influence on stellar spectra, cosmological topics utilizing Cosmic Background Explorer (COBE) data and radioastronomic mapping as well as cosmic gravitational instability calculations, astrometry of open clusters amd solar gravitational focusing, extremely energetic gamma rays, interacting binaries, and balloon-borne instrumentation. Other papers proposed an active Search for Extraterrestrial Intelligence (SETI) communication scheme to neighboring solar-like systems and more direct involvement of and with the public in astronomy and space exploration projects.
5-Beam ADCP Deployment Strategy Considerations
NASA Astrophysics Data System (ADS)
Moore, T.; Savidge, D. K.; Gargett, A.
2016-02-01
With the increasing availability of 5 beam ADCPs and expanding opportunities for their deployment within both observatory and dedicated process study settings, refinements in deployment strategies are needed.Measuring vertical velocities directly with a vertically oriented acoustic beam requires that the instrument be stably mounted and leveled within fractions of a degree. Leveled shallow water deployments to date have utilized divers to jet pipes into the sand for stability, manually mount the instruments on the pipes, and level them. Leveling has been guided by the deployed instrument's pitch and roll output, available in real-time because of the observatory settings in which the deployments occurred. To expand the range of feasible deployments to deeper, perhaps non-real-time capable settings, alternatives to diver deployment and leveling must be considered. To determine stability requirements, mooring motion (heading, pitch and roll) has been sampled at 1Hz by gimballed ADCPs at a range of instrument deployment depths, and in shrouded and unshrouded cages. Conditions under which ADCP cages resting on the bottom experience significant shifts in tilt, roll or heading are assessed using co-located wind and wave measurements. The accuracy of estimating vertical velocities using all five beams relative to a well leveled vertical single beam is assessed from archived high frequency five beam data, to explore whether easing the leveling requirement is feasible.
ERIC Educational Resources Information Center
Doabler, Christian; Smolkowski, Keith; Fien, Hank; Kosty, Derek B.; Cary, Mari Strand
2010-01-01
In this paper, the authors report research focused directly on the validation of the Coding of Academic Teacher-Student interactions (CATS) direct observation instrument. They use classroom information gathered by the CATS instrument to better understand the potential mediating variables hypothesized to influence student achievement. Their study's…
Lunardini, David; Arington, Richard; Canacari, Elena G; Gamboa, Kelly; Wagner, Katiri; McGuire, Kevin J
2014-09-15
Case study OBJECTIVE.: To optimize the utilization of operating room instruments for orthopedic and neurosurgical spine cases in an urban level 1 academic medical center through application of Lean principles. Process improvement systems such as Lean have been adapted to health care and offer an opportunity for frank assessment of surgical routines to increase efficiency and enhance value. The goal has been to safely reduce the financial burden to the health care system without compromising care and if possible reallocate these resources or gains in efficiency to further improve the value to the patient. The investigators identified instruments as a source of waste in the operating room and proposed a Lean process assessment. The instruments and the instrument processing workflow were described. An audit documented the utilization of each instrument by orthopedic surgeons and neurosurgeons through observation of spine cases. The data were then presented to the stakeholders, including surgeons, the perioperative director, and representatives from nursing, central processing, and the surgical technicians. Of the 38 cases audited, only 89 (58%) of the instruments were used at least once. On the basis of the data and stakeholder consensus, 63 (41%) of the instruments were removed, resulting in a weight reduction of 17.5 lb and consolidation of 2 instrument sets into 1. Projected cost savings were approximately $41,000 annually. Although new instruments were purchased to standardize sets, the return on investment was estimated to be 2 years. Inefficient surgical routines may comprise significant resource waste in an institution. Process assessment is an important tool in decreasing health care costs, with objectivity provided by Lean or similar principles, and essential impetus to change provided by stakeholders. 4.
ERIC Educational Resources Information Center
Bielinska-Kwapisz, Agnieszka; Brown, F. William
2014-01-01
The publishers of the Major Field Test in Business (MFT-B), an assessment of learning instrument, provide a list of institutions utilizing the instrument and a table that allows for comparison of local MFT-B mean scores to those of other institutions. The absence of information regarding the comparison group's characteristics limits the validity…
FIRST, a fibered aperture masking instrument: Results of the Lick observing campaign
NASA Astrophysics Data System (ADS)
Bordwell, Baylee; Duchene, Gaspard; Huby, Elsa; Goebel, Sean; Marchis, Franck; Perrin, Guy; Lacour, Sylvestre; Kotani, Takayuki; Gates, Elinor L.; Choquet, Elodie
2015-01-01
FIRST is a prototype instrument aimed at achieving high dynamic range and angular resolution in ground-based images at visible wavelengths near the diffraction limit. FIRST utilizes an aperture masking-like technique that makes use of single-mode fibers and pupil remapping to maximize the area of the telescope mirror in use. While located at Lick observatory in 2011 and 2012, FIRST observed 25 binary systems with the Shane 3m telescope, with separations ranging from 20 to 200 mas, comparable to the 50 mas diffraction limit for our central wavelength. Huby et al. (2013) has reported results for the Capella system that established the utility of FIRST for characterizing stellar binaries using the directly measured spectral flux ratio. Using an improved data analysis pipeline, we obtained closure phase measurements for a majority of the targets observed at Lick, and derived angular separations and spectral flux ratios. From the spectral flux ratios we obtained spectra for the companions over at least 600-850 nm with R~300. Finally, by obtaining results for many binary systems we have better constrained the current performance of FIRST, which has an exciting future ahead at its current location behind SCExAO at the Subaru 8.2 m telescope, where it will eventually become available for general use by the astronomical community.
NASA Astrophysics Data System (ADS)
Aliyu, Yahaya A.; Botai, Joel O.
2018-04-01
The retrieval characteristics for a city-scale satellite experiment was explored over a Nigerian city. The study evaluated carbon monoxide and aerosol contents in the city atmosphere. We utilized the MSA Altair 5× gas detector and CW-HAT200 particulate counter to investigate the city-scale monitoring capabilities of satellite pollution observing instruments; atmospheric infrared sounder (AIRS), measurement of pollution in the troposphere (MOPITT), moderate resolution imaging spectroradiometer (MODIS), multi-angle imaging spectroradiometer (MISR) and ozone monitoring instrument (OMI). To achieve this, we employed the Kriging interpolation technique to collocate the satellite pollutant estimations over 19 ground sample sites for the period of 2015-2016. The portable pollutant devices were validated using the WHO air filter sampling model. To determine the city-scale performance of the satellite datasets, performance indicators: correlation coefficient, model efficiency, reliability index and root mean square error, were adopted as measures. The comparative analysis revealed that MOPITT carbon monoxide (CO) and MODIS aerosol optical depth (AOD) estimates are the appropriate satellite measurements for ground equivalents in Zaria, Nigeria. Our findings were within the acceptable limits of similar studies that utilized reference stations. In conclusion, this study offers direction to Nigeria's air quality policy organizers about available alternative air pollution measurements for mitigating air quality effects within its limited resource environment.
The Autism Diagnosis in Translation: Shared Affect in Children and Mouse Models of ASD
Bishop, Somer L.; Lahvis, Garet P.
2013-01-01
In recent years, there have been significant improvements in assessment and diagnostic procedures for autism spectrum disorders (ASD). Standardized diagnostic instruments have been developed, promoting consistent diagnostic practices among clinicians. For clinical researchers, these instruments have facilitated collaborations across different sites by providing standardized metrics with which to evaluate ASD symptoms. Nevertheless, because ASD remains a diagnosis that is defined on the basis of behavior, there are significant challenges associated with modeling ASD social behaviors in laboratory animals. In order to more effectively study the causes of ASD symptoms and behaviors, there is a need to develop new ways of measuring social behaviors that can be applied to non-human species. Critically, while verbal dialogue between the clinician and patient is integral to clinical diagnoses, it cannot be employed for studies of animal models. However, observations of autistic-like social interactions can be modeled in animals. In this regard, communication between professionals in the clinical and basic sciences is necessary to break down the complex diagnosis into units of social impairment that can be more feasibly measured in different species. This paper presents a discussion between an animal researcher and a clinical psychologist. Using shared affect as an example, we explore potential avenues for increasing the utility of animal models to move us toward a better understanding of the mechanisms underlying social impairments in ASD. In the absence of molecular biomarkers that can be used to diagnose ASD, current diagnostic tools depend upon clinical assessments of behavior. Research efforts with human subjects have successfully utilized standardized diagnostic instruments, which include clinician interviews with parents and direct observation of the children themselves (Risi et al., 2006). However, because clinical instruments are semi-structured and rely heavily on dynamic social processes and clinical skill, scores from these measures do not necessarily lend themselves directly to experimental investigations into the causes of ASD. Studies of the neurobiology of autism require experimental animal models. Mice are particularly useful, in this regard, for elucidating genetic and toxicologjcal contributions to impairments in social function (Halladay et al., 2009). Behavioral tests have been developed that are relevant to autism (Crawley, 2004, 2007), including measures of repetitive behaviors (Lewis, Tanimura, Lee, & Bodfish, 2007; Moy et al., 2008), social behavior (Brodkin, 2007; Lijam et al., 1997; Moretti, Bouwknecht, Teague, Paylor, & Zoghbi, 2005), and vocal communication (Panksepp et al., 2007). Advances also include development of high-throughput measures of mouse sociability that can be used to reliably compare inbred mouse strains (Moy, et al., 2008; Nadler et al., 2004), as well as measures of social reward (Panksepp & Lahvis, 2007) and empathy (Chen, Panksepp, & Lahvis, 2009; Langford et al., 2006). With continued generation of mouse gene-targeted mice that are directly relevant to genetic linkages in ASD, there remains an urgent need to utilize a full suite of mouse behavioral tests that allows for a comprehensive assessment of the spectrum of social difficulties relevant to ASD. Using impairments in shared affect as an example, this paper explores potential avenues for collaboration between clinical and basic scientists, within an amply considered translational framework. PMID:21882361
An Instrumental Perspective on CSCL Systems
ERIC Educational Resources Information Center
Lonchamp, Jacques
2012-01-01
The theory of instrumental genesis of Rabardel relates the social and the technical through the concept of instrument. An instrument is defined as a mixed entity made up by an artifact, the technical/material part, and a set of utilization schemes, the social/behavioural part, which both result from users' constructive activities. This theory is…
Mukherjee, Snigdha; Canterberry, Melanie; Yore, Jennifer B; Ledford, Edward Cannon; Carton, Thomas W
2017-08-24
The relationship between mental health status and smoking is complicated and often confounded by bi-directionality, yet most research on this relationship assumes exogeneity. The goal of this article is to implement an instrumental variable approach to (1) test the exogeneity assumption and (2) report on the association between mental health status and smoking post-disaster. This analysis utilizes the 2006 and 2007 Louisiana Behavioral Risk Factor Surveillance Survey to examine the link between mental distress and smoking in areas affected by Hurricanes Katrina and Rita. Residence in a hurricane-affected parish (county) was used as an instrumental variable for mental distress. Just over 22% of the sample resided in a hurricane-affected parish. Residents of hurricane-affected parishes were significantly more likely to report occasional and frequent mental distress. Residence in a hurricane-affected parish was not significantly associated with smoking status. With residence established as a salient instrumental variable for mental distress, the exogeneity assumption was tested and confirmed in this sample. A dose-response relationship existed between mental distress and smoking, with smoking prevalence increasing directly (and non-linearly) with mental distress. In this sample, the relationship between mental distress and smoking status was exogenous and followed a dose-response relationship, suggesting that the disasters did not result in an uptake of smoking initiation, but that the higher amounts of mental distress may lead to increased use among smokers. The findings suggest that tobacco control programs should devise unique strategies to address mentally distressed populations.
Junghaenel, Doerte U.; Schneider, Stefan; Stone, Arthur A.; Christodoulou, Christopher; Broderick, Joan E.
2014-01-01
Objective This study examined the ecological validity and clinical utility of NIH Patient Reported-Outcomes Measurement Information System (PROMIS®) instruments for anger, depression, and fatigue in women with premenstrual symptoms. Methods One-hundred women completed daily diaries and weekly PROMIS assessments over 4 weeks. Weekly assessments were administered through Computerized Adaptive Testing (CAT). Weekly CATs and corresponding daily scores were compared to evaluate ecological validity. To test clinical utility, we examined if CATs could detect changes in symptom levels, if these changes mirrored those obtained from daily scores, and if CATs could identify clinically meaningful premenstrual symptom change. Results PROMIS CAT scores were higher in the pre-menstrual than the baseline (ps < .0001) and post-menstrual (ps < .0001) weeks. The correlations between CATs and aggregated daily scores ranged from .73 to .88 supporting ecological validity. Mean CAT scores showed systematic changes in accordance with the menstrual cycle and the magnitudes of the changes were similar to those obtained from the daily scores. Finally, Receiver Operating Characteristic (ROC) analyses demonstrated the ability of the CATs to discriminate between women with and without clinically meaningful premenstrual symptom change. Conclusions PROMIS CAT instruments for anger, depression, and fatigue demonstrated validity and utility in premenstrual symptom assessment. The results provide encouraging initial evidence of the utility of PROMIS instruments for the measurement of affective premenstrual symptoms. PMID:24630180
NASA Astrophysics Data System (ADS)
Schwichow, Martin; Christoph, Simon; Boone, William J.; Härtig, Hendrik
2016-01-01
The so-called control-of-variables strategy (CVS) incorporates the important scientific reasoning skills of designing controlled experiments and interpreting experimental outcomes. As CVS is a prominent component of science standards appropriate assessment instruments are required to measure these scientific reasoning skills and to evaluate the impact of instruction on CVS development. A detailed review of existing CVS instruments suggests that they utilize different, and only a few of the four, critical CVS sub-skills in the item development. This study presents a new CVS assessment instrument (CVS Inventory, CVSI) and investigates the validity of student measures derived from this instrument utilizing Rasch analyses. The results indicate that the CVSI produces reliable and valid student measures with regard to CVS. Furthermore, the results show that the item difficulty depends on the CVS sub-skills utilized in item development, but not on the item content. Accordingly, previous instruments that are restricted to a few CVS sub-skills tend to over- or underestimate students' CVS skills. In addition, these results indicate that students are able to use CVS as a domain general strategy in multiple content areas. Consequences for science instruction and assessment are discussed.
A risk analysis approach applied to field surveillance in utility meters in legal metrology
NASA Astrophysics Data System (ADS)
Rodrigues Filho, B. A.; Nonato, N. S.; Carvalho, A. D.
2018-03-01
Field surveillance represents the level of control in metrological supervision responsible for checking the conformity of measuring instruments in-service. Utility meters represent the majority of measuring instruments produced by notified bodies due to self-verification in Brazil. They play a major role in the economy once electricity, gas and water are the main inputs to industries in their production processes. Then, to optimize the resources allocated to control these devices, the present study applied a risk analysis in order to identify among the 11 manufacturers notified to self-verification, the instruments that demand field surveillance.
Miyanji, Firoz; Slobogean, Gerard P; Samdani, Amer F; Betz, Randal R; Reilly, Christopher W; Slobogean, Bronwyn L; Newton, Peter O
2012-05-02
The treatment of patients with large adolescent idiopathic scoliosis curves has been associated with increased surgical complexity. The purpose of this study was to determine whether surgical correction of larger adolescent idiopathic scoliosis curves increased the utilization of health-care resources and to identify potential predictors associated with increased perioperative health-care resource utilization. A nested cohort of patients with adolescent idiopathic scoliosis with Lenke type 1A and 1B curves were identified from a prospective longitudinal multicenter database. Four perioperative outcomes were selected as the primary health-care resource utilization outcomes of interest: operative time, number of vertebral levels instrumented, duration of hospitalization, and allogeneic blood transfusion. The effect of curve magnitude on these outcomes was assessed with use of univariate and multivariate regression. Three hundred and twenty-five patients with a mean age of 15 ± 2 years were included. The mean main thoracic curve was 54.4° ± 7.8°. Larger curves were associated with longer operative time (p = 0.03), a greater number of vertebral levels instrumented (p = 0.0005), and the need for blood transfusion (with every 10° increase associated with 1.5 times higher odds of receiving a transfusion). In addition to curve magnitude, surgical center, bone graft method, and upper and lower instrumented levels were strong predictors of operative time (R2 = 0.76). The duration of hospitalization was influenced by the surgical center and intraoperative blood loss (R2 < 0.4), whereas the number of levels instrumented was influenced by the curve magnitude, curve correction percentage, upper instrumented vertebra, and surgical center (R2 = 0.64). Correction of larger curves was associated with increased utilization of perioperative health-care resources, specifically longer operative time, a greater number of vertebral levels instrumented, and higher odds of receiving a blood transfusion.
An overview of instrumentation for the Large Binocular Telescope
NASA Astrophysics Data System (ADS)
Wagner, R. Mark
2010-07-01
An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27 × 27) mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6 field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4 × 4) imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0.5 × 0.5) imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support. Over the past two years the LBC and the first LUCIFER instrument have been brought into routine scientific operation and MODS1 commissioning is set to begin in the fall of 2010.
An overview of instrumentation for the Large Binocular Telescope
NASA Astrophysics Data System (ADS)
Wagner, R. Mark
2006-06-01
An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' × 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 × 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.
An overview of instrumentation for the Large Binocular Telescope
NASA Astrophysics Data System (ADS)
Wagner, R. Mark
2004-09-01
An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27'x 27') UB/VRI optimized mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6\\arcmin\\ field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4'x 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 x 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench beam combiner with visible and near-infrared imagers utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC/NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.
An overview of instrumentation for the Large Binocular Telescope
NASA Astrophysics Data System (ADS)
Wagner, R. Mark
2008-07-01
An overview of instrumentation for the Large Binocular Telescope is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' × 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the straight-through F/15 Gregorian focus incorporating multiple slit masks for multi-object spectroscopy over a 6 field and spectral resolutions of up to 8000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCIFER), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at a bent interior focal station and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multi-object spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0.5' × 0.5') imaging and long-slit spectroscopy. Strategic instruments under development for the remaining two combined focal stations include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. The availability of all these instruments mounted simultaneously on the LBT permits unique science, flexible scheduling, and improved operational support.
Prigent, Amélie; Kamendje-Tchokobou, Blaise; Chevreul, Karine
2017-11-01
Health-related quality of life (HRQoL) is a widely used concept in the assessment of health care. Some generic HRQoL instruments, based on specific algorithms, can generate utility scores which reflect the preferences of the general population for the different health states described by the instrument. This study aimed to investigate the relationships between utility scores and potentially associated factors in patients with mental disorders followed in inpatient and/or outpatient care settings using two statistical methods. Patients were recruited in four psychiatric sectors in France. Patient responses to the SF-36 generic HRQoL instrument were used to calculate SF-6D utility scores. The relationships between utility scores and patient socio-demographic, clinical characteristics, and mental health care utilization, considered as potentially associated factors, were studied using OLS and quantile regressions. One hundred and seventy six patients were included. Women, severely ill patients and those hospitalized full-time tended to report lower utility scores, whereas psychotic disorders (as opposed to mood disorders) and part-time care were associated with higher scores. The quantile regression highlighted that the size of the associations between the utility scores and some patient characteristics varied along with the utility score distribution, and provided more accurate estimated values than OLS regression. The quantile regression may constitute a relevant complement for the analysis of factors associated with utility scores. For policy decision-making, the association of full-time hospitalization with lower utility scores while part-time care was associated with higher scores supports the further development of alternatives to full-time hospitalizations.
Modeling, simulation and control for a cryogenic fluid management facility, preliminary report
NASA Technical Reports Server (NTRS)
Turner, Max A.; Vanbuskirk, P. D.
1986-01-01
The synthesis of a control system for a cryogenic fluid management facility was studied. The severe demand for reliability as well as instrumentation and control unique to the Space Station environment are prime considerations. Realizing that the effective control system depends heavily on quantitative description of the facility dynamics, a methodology for process identification and parameter estimation is postulated. A block diagram of the associated control system is also produced. Finally, an on-line adaptive control strategy is developed utilizing optimization of the velocity form control parameters (proportional gains, integration and derivative time constants) in appropriate difference equations for direct digital control. Of special concern are the communications, software and hardware supporting interaction between the ground and orbital systems. It is visualized that specialist in the OSI/ISO utilizing the Ada programming language will influence further development, testing and validation of the simplistic models presented here for adaptation to the actual flight environment.
Bender, Donna S; Morey, Leslie C; Skodol, Andrew E
2011-07-01
Personality disorders are associated with fundamental disturbances of self and interpersonal relations, problems that vary in severity within and across disorders. This review surveyed clinician-rated measures of personality psychopathology that focus on self-other dimensions to explore the feasibility and utility of constructing a scale of severity of impairment in personality functioning for DSM-5. Robust elements of the instruments were considered in creating a continuum of personality functioning based on aspects of identity, self-direction, empathy, and intimacy. Building on preliminary findings (Morey et al., 2011 /this issue), the proposed Levels of Personality Functioning will be subjected to extensive empirical testing in the DSM-5 field trials and elsewhere. The resulting version of this severity measure is expected to have clinical utility in identifying personality psychopathology, planning treatment, building the therapeutic alliance, and studying treatment course and outcome.
Karouia, Fathi; Peyvan, Kianoosh; Pohorille, Andrew
2017-11-15
Space biotechnology is a nascent field aimed at applying tools of modern biology to advance our goals in space exploration. These advances rely on our ability to exploit in situ high throughput techniques for amplification and sequencing DNA, and measuring levels of RNA transcripts, proteins and metabolites in a cell. These techniques, collectively known as "omics" techniques have already revolutionized terrestrial biology. A number of on-going efforts are aimed at developing instruments to carry out "omics" research in space, in particular on board the International Space Station and small satellites. For space applications these instruments require substantial and creative reengineering that includes automation, miniaturization and ensuring that the device is resistant to conditions in space and works independently of the direction of the gravity vector. Different paths taken to meet these requirements for different "omics" instruments are the subjects of this review. The advantages and disadvantages of these instruments and technological solutions and their level of readiness for deployment in space are discussed. Considering that effects of space environments on terrestrial organisms appear to be global, it is argued that high throughput instruments are essential to advance (1) biomedical and physiological studies to control and reduce space-related stressors on living systems, (2) application of biology to life support and in situ resource utilization, (3) planetary protection, and (4) basic research about the limits on life in space. It is also argued that carrying out measurements in situ provides considerable advantages over the traditional space biology paradigm that relies on post-flight data analysis. Published by Elsevier Inc.
Ball, Chad G; Campbell, Andre; Grondin, Sean C; Dixon, Elijah; DuBose, Joseph; McBeth, Paul B; Lall, Rohan
2016-09-01
Solid organ (liver, spleen and kidney) haemorrhage is often life threatening and can be difficult to stop in critically ill patients. Traditional techniques for arresting this ongoing bleeding include coagulation by high voltage cautery (Bovie), topical haemostatic application, and the delivery of ignited argon gas. The goal of this study was to evaluate the efficacy of a new energy device for arresting persistent solid organ haemorrhage. A novel instrument utilizing bipolar radiofrequency (RF) energy which acts to ignite/boil dripping saline from a simple hand piece was employed to arrest ongoing bleeding from solid organ injuries at 2 high volume, level 1 trauma centres. This instrument is extrapolated from experience within elective hepatic resections. Standard statistics were employed (p<0.05=significant). From January 2013 to January 2015, 36 severely injured patients (mean injury severity score=31; blunt mechanisms=32/36 (89%)) underwent use of this new saline/RF energy instrument to arrest ongoing haemorrhage from the liver (29), spleen (5) and kidney (2). Of these patients, 25 received instrument use during an initial laparotomy, while 11 patients underwent use following removal of sponges during a return laparotomy after an initial damage control procedure. Success in arresting ongoing haemorrhage was 97% (35/36) in these highly selected cases. The surgeons reported an 'ease of use' score of 4.9 out of 5. No postoperative complications (including delayed haemorrhage) were noted as a direct result of the energy instrument. This simple saline/RF energy instrument has the potential to arrest ongoing solid organ surface/capsular bleeding, as well as moderate haemorrhage associated with deep lacerations. Copyright © 2016 Elsevier Ltd. All rights reserved.
A structured review of health utility measures and elicitation in advanced/metastatic breast cancer.
Hao, Yanni; Wolfram, Verena; Cook, Jennifer
2016-01-01
Health utilities are increasingly incorporated in health economic evaluations. Different elicitation methods, direct and indirect, have been established in the past. This study examined the evidence on health utility elicitation previously reported in advanced/metastatic breast cancer and aimed to link these results to requirements of reimbursement bodies. Searches were conducted using a detailed search strategy across several electronic databases (MEDLINE, EMBASE, Cochrane Library, and EconLit databases), online sources (Cost-effectiveness Analysis Registry and the Health Economics Research Center), and web sites of health technology assessment (HTA) bodies. Publications were selected based on the search strategy and the overall study objectives. A total of 768 publications were identified in the searches, and 26 publications, comprising 18 journal articles and eight submissions to HTA bodies, were included in the evidence review. Most journal articles derived utilities from the European Quality of Life Five-Dimensions questionnaire (EQ-5D). Other utility measures, such as the direct methods standard gamble (SG), time trade-off (TTO), and visual analog scale (VAS), were less frequently used. Several studies described mapping algorithms to generate utilities from disease-specific health-related quality of life (HRQOL) instruments such as European Organization for Research and Treatment of Cancer Quality of Life Questionnaire - Core 30 (EORTC QLQ-C30), European Organization for Research and Treatment of Cancer Quality of Life Questionnaire - Breast Cancer 23 (EORTC QLQ-BR23), Functional Assessment of Cancer Therapy - General questionnaire (FACT-G), and Utility-Based Questionnaire-Cancer (UBQ-C); most used EQ-5D as the reference. Sociodemographic factors that affect health utilities, such as age, sex, income, and education, as well as disease progression, choice of utility elicitation method, and country settings, were identified within the journal articles. Most submissions to HTA bodies obtained utility values from the literature rather than exploring the HRQOL data obtained during clinical development. This was critiqued by the National Institute for Health and Clinical Excellence (NICE). Furthermore, the impact of age on utilities was highlighted by NICE and it was suggested that an age match of the study population should be attempted. Health utilities are recorded across the globe to varying extents and using differing elicitation methods. Manufacturers seeking reimbursement need to be aware of the country-specific requirements for elicitation of health utilities.
A structured review of health utility measures and elicitation in advanced/metastatic breast cancer
Hao, Yanni; Wolfram, Verena; Cook, Jennifer
2016-01-01
Background Health utilities are increasingly incorporated in health economic evaluations. Different elicitation methods, direct and indirect, have been established in the past. This study examined the evidence on health utility elicitation previously reported in advanced/metastatic breast cancer and aimed to link these results to requirements of reimbursement bodies. Methods Searches were conducted using a detailed search strategy across several electronic databases (MEDLINE, EMBASE, Cochrane Library, and EconLit databases), online sources (Cost-effectiveness Analysis Registry and the Health Economics Research Center), and web sites of health technology assessment (HTA) bodies. Publications were selected based on the search strategy and the overall study objectives. Results A total of 768 publications were identified in the searches, and 26 publications, comprising 18 journal articles and eight submissions to HTA bodies, were included in the evidence review. Most journal articles derived utilities from the European Quality of Life Five-Dimensions questionnaire (EQ-5D). Other utility measures, such as the direct methods standard gamble (SG), time trade-off (TTO), and visual analog scale (VAS), were less frequently used. Several studies described mapping algorithms to generate utilities from disease-specific health-related quality of life (HRQOL) instruments such as European Organization for Research and Treatment of Cancer Quality of Life Questionnaire – Core 30 (EORTC QLQ-C30), European Organization for Research and Treatment of Cancer Quality of Life Questionnaire – Breast Cancer 23 (EORTC QLQ-BR23), Functional Assessment of Cancer Therapy – General questionnaire (FACT-G), and Utility-Based Questionnaire-Cancer (UBQ-C); most used EQ-5D as the reference. Sociodemographic factors that affect health utilities, such as age, sex, income, and education, as well as disease progression, choice of utility elicitation method, and country settings, were identified within the journal articles. Most submissions to HTA bodies obtained utility values from the literature rather than exploring the HRQOL data obtained during clinical development. This was critiqued by the National Institute for Health and Clinical Excellence (NICE). Furthermore, the impact of age on utilities was highlighted by NICE and it was suggested that an age match of the study population should be attempted. Conclusion Health utilities are recorded across the globe to varying extents and using differing elicitation methods. Manufacturers seeking reimbursement need to be aware of the country-specific requirements for elicitation of health utilities. PMID:27382319
Reconstructing pre-instrumental streamflow in Eastern Australia using a water balance approach
NASA Astrophysics Data System (ADS)
Tozer, C. R.; Kiem, A. S.; Vance, T. R.; Roberts, J. L.; Curran, M. A. J.; Moy, A. D.
2018-03-01
Streamflow reconstructions based on paleoclimate proxies provide much longer records than the short instrumental period records on which water resource management plans are currently based. In Australia there is a lack of in-situ high resolution paleoclimate proxy records, but remote proxies with teleconnections to Australian climate have utility in producing streamflow reconstructions. Here we investigate, via a case study for a catchment in eastern Australia, the novel use of an Antarctic ice-core based rainfall reconstruction within a Budyko-framework to reconstruct ∼1000 years of annual streamflow. The resulting streamflow reconstruction captures interannual to decadal variability in the instrumental streamflow, validating both the use of the ice core rainfall proxy record and the Budyko-framework method. In the preinstrumental era the streamflow reconstruction shows longer wet and dry epochs and periods of streamflow variability that are higher than observed in the instrumental era. Importantly, for both the instrumental record and preinstrumental reconstructions, the wet (dry) epochs in the rainfall record are shorter (longer) in the streamflow record and this non-linearity must be considered when inferring hydroclimatic risk or historical water availability directly from rainfall proxy records alone. These insights provide a better understanding of present infrastructure vulnerability in the context of past climate variability for eastern Australia. The streamflow reconstruction presented here also provides a better understanding of the range of hydroclimatic variability possible, and therefore represents a more realistic baseline on which to quantify the potential impacts of anthropogenic climate change on water security.
Robotics in Cardiac Surgery: Past, Present, and Future
Bush, Bryan; Nifong, L. Wiley; Chitwood, W. Randolph
2013-01-01
Robotic cardiac operations evolved from minimally invasive operations and offer similar theoretical benefits, including less pain, shorter length of stay, improved cosmesis, and quicker return to preoperative level of functional activity. The additional benefits offered by robotic surgical systems include improved dexterity and degrees of freedom, tremor-free movements, ambidexterity, and the avoidance of the fulcrum effect that is intrinsic when using long-shaft endoscopic instruments. Also, optics and operative visualization are vastly improved compared with direct vision and traditional videoscopes. Robotic systems have been utilized successfully to perform complex mitral valve repairs, coronary revascularization, atrial fibrillation ablation, intracardiac tumor resections, atrial septal defect closures, and left ventricular lead implantation. The history and evolution of these procedures, as well as the present status and future directions of robotic cardiac surgery, are presented in this review. PMID:23908867
Determination of plutonium in spent nuclear fuel using high resolution X-ray
McIntosh, Kathryn G.; Reilly, Sean D.; Havrilla, George J.
2015-05-30
Characterization of Pu is an essential aspect of safeguards operations at nuclear fuel reprocessing facilities. A novel analysis technique called hiRX (high resolution X-ray) has been developed for the direct measurement of Pu in spent nuclear fuel dissolver solutions. hiRX is based on monochromatic wavelength dispersive X-ray fluorescence (MWDXRF), which provides enhanced sensitivity and specificity compared with conventional XRF techniques. A breadboard setup of the hiRX instrument was calibrated using spiked surrogate spent fuel (SSF) standards prepared as dried residues. Samples of actual spent fuel were utilized to evaluate the performance of the hiRX. The direct detection of just 39more » ng of Pu is demonstrated. Initial quantitative results, with error of 4–27% and precision of 2% relative standard deviation (RSD), were obtained for spent fuel samples. The limit of detection for Pu (100 s) within an excitation spot of 200 μm diameter was 375 pg. This study demonstrates the potential for the hiRX technique to be utilized for the rapid, accurate, and precise determination of Pu. Moreover, the results highlight the analytical capability of hiRX for other applications requiring sensitive and selective nondestructive analyses.« less
Enabling a Science Support Structure for NASAs Global Hawk UASs
NASA Technical Reports Server (NTRS)
Sullivan, Donald V.
2014-01-01
In this paper we describe the information technologies developed by NASA for the Winter/Spring 2013/2014, and Fall 2014, NASA Earth Venture Campaigns, Hurricane and Severe Storm Sentinel (HS3) and Airborne Tropical TRopopause EXperiment (ATTREX). These campaigns utilized Global Hawk UAS vehicles equipped at the NASA Armstrong (previously Dryden) Flight Research Facility (AFRC), Edwards Air Force Base, California, and operated from there, the NASA Wallops Flight Facility (WFF), Virginia, and Anderson Air Force Base (AAFB), Guam. Part of this enabling infrastructure utilized a layer 2 encrypted terrestrial Virtual Local Area Network (VLAN) that, at times, spanned greater than ten thousand miles (AAFB <-> AFRC <-> WFF) and was routed over geosynchronous Ku band communication Satellites directly to the aircraft sensor network. This infrastructure enabled seamless hand off between Satellites, and Satellite ground stations in Guam, California and Virginia, so allowing simultaneous Aircraft Command and Control and Science operations from remote locations. Additionally, we will describe the other elements of this infrastructure, from on-board geo-enabled databases, to real time communications directly from the instruments (in some cases, more than twelve were carried, and simultaneously operated, on one aircraft) to the researchers and other interested parties, world wide.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McIntosh, Kathryn G.; Reilly, Sean D.; Havrilla, George J.
Characterization of Pu is an essential aspect of safeguards operations at nuclear fuel reprocessing facilities. A novel analysis technique called hiRX (high resolution X-ray) has been developed for the direct measurement of Pu in spent nuclear fuel dissolver solutions. hiRX is based on monochromatic wavelength dispersive X-ray fluorescence (MWDXRF), which provides enhanced sensitivity and specificity compared with conventional XRF techniques. A breadboard setup of the hiRX instrument was calibrated using spiked surrogate spent fuel (SSF) standards prepared as dried residues. Samples of actual spent fuel were utilized to evaluate the performance of the hiRX. The direct detection of just 39more » ng of Pu is demonstrated. Initial quantitative results, with error of 4–27% and precision of 2% relative standard deviation (RSD), were obtained for spent fuel samples. The limit of detection for Pu (100 s) within an excitation spot of 200 μm diameter was 375 pg. This study demonstrates the potential for the hiRX technique to be utilized for the rapid, accurate, and precise determination of Pu. Moreover, the results highlight the analytical capability of hiRX for other applications requiring sensitive and selective nondestructive analyses.« less
Malin, David H; Schaar, Krystal L; Izygon, Jonathan J; Nghiem, Duyen M; Jabitta, Sikirat Y; Henceroth, Mallori M; Chang, Yu-Hsuan; Daggett, Jenny M; Ward, Christopher P
2015-08-01
The Morris water maze is routinely used to explore neurobiological mechanisms of working memory. Humans can often acquire working memory relevant to performing a task by mere sensory observation, without having to actually perform the task followed by reinforcement. This can be modeled in the water maze through direct placement of a rat on the escape platform so that it can observe the location, and then assessing the subject's performance in swimming back to the platform. However, direct placement procedures have hardly been studied for two decades, reflecting a controversy about whether direct placement resulted in sufficiently rapid and direct swims back to the platform. In the present study, utilizing revised training methods, a more comprehensive measure of trajectory directness, a more rigorous sham-trained control procedure and an optimal placement-test interval, rats swam almost directly back to the platform in under 4s, significantly more quickly and directly than sham-trained subjects. Muscarinic cholinergic mechanisms, which are inactivated by scopolamine, are essential to memory for standard learning paradigms in the water maze. This experiment determined whether this would also be true for latent learning. ANOVA revealed significant negative effects of scopolamine on both speed and accuracy of trajectory, as well as significant positive effects of direct placement training vs. sham-training. In a probe trial, placement-trained animals without scopolamine spent significantly more time and path length in the target quadrant than trained rats with scopolamine and sham-trained rats without scopolamine. Scopolamine impairments are likely due to effects on memory, since the same dose had little effect on performance with a visible platform. The revised direct placement model offers a means of further comparing the neural mechanisms of latent learning with those of standard instrumental learning. Copyright © 2015 Elsevier Inc. All rights reserved.
Novel system for automatic measuring diopter based on ARM circuit block
NASA Astrophysics Data System (ADS)
Xue, Feng; Zhong, Lei; Chen, Zhe; Xue, Deng-pan; Li, Xiang-ning
2009-07-01
Traditional commercial instruments utilized in vision screening programs cannot satisfy the request for real-time diopter measurement by far, and their success is limited by some defectiveness such as computer-attached, clumsy volume, and low accuracy of parameters measured, etc. In addition, astigmatic eyes cannot be determined in many devices. This paper proposes a new design of diopter measurement system based on SAMSUNG's ARM9 circuit block. There are several contributions in the design. The new developed system has not only the function of automatically measuring diopter, but also the advantages of the low cost, and especially the simplicity and portability. Besides, by placing point sources in three directions, the instrument can determine astigmatic eyes at the same time. Most of the details are introduced as the integrated design of measuring system, interface circuit of embedded system and so on. Through a preliminary experiment, it is proved that the system keeps good feasibility and validity. The maximum deviation of measurement result is 0.344D.The experimental results also demonstrate the system can provide the service needed for real-time applications. The instrument present here is expected to be widely applied in many fields such as the clinic and home healthcare.
NASA Astrophysics Data System (ADS)
Taj-Eddin, Islam A. T. F.; Afifi, Mahmoud; Korashy, Mostafa; Ahmed, Ali H.; Cheng, Ng Yoke; Hernandez, Evelyng; Abdel-Latif, Salma M.
2017-11-01
Plant aliveness is proven through laboratory experiments and special scientific instruments. We aim to detect the degree of animation of plants based on the magnification of the small color changes in the plant's green leaves using the Eulerian video magnification. Capturing the video under a controlled environment, e.g., using a tripod and direct current light sources, reduces camera movements and minimizes light fluctuations; we aim to reduce the external factors as much as possible. The acquired video is then stabilized and a proposed algorithm is used to reduce the illumination variations. Finally, the Euler magnification is utilized to magnify the color changes on the light invariant video. The proposed system does not require any special purpose instruments as it uses a digital camera with a regular frame rate. The results of magnified color changes on both natural and plastic leaves show that the live green leaves have color changes in contrast to the plastic leaves. Hence, we can argue that the color changes of the leaves are due to biological operations, such as photosynthesis. To date, this is possibly the first work that focuses on interpreting visually, some biological operations of plants without any special purpose instruments.
Intermediate outcomes of a tribal community public health infrastructure assessment.
English, Kevin C; Wallerstein, Nina; Chino, Michelle; Finster, Carolyn E; Rafelito, Alvin; Adeky, Sarah; Kennedy, Marianna
2004-01-01
The purpose of this collaborative participatory project was to assess the strengths and needs of a tribal community as part of a larger public health capacity building program. Key project partners included: the Ramah Band of Navajo Indians, the Albuquerque Area Indian Health Board, the University of New Mexico Masters in Public Health Program, and the University of Nevada, Las Vegas, American Indian Research and Education Center. Principal intervention steps entailed: 1) relationship-building activities among tribal programs and between the Tribe and the scientific community; 2) an orientation to public health; 3) a comprehensive public health infrastructure assessment, utilizing a standardized CDC instrument; and 4) a prioritization of identified needs. The direct outcome was the development and beginning implementation of a community specific public health strategic action plan. Broader results included: 1) increased comprehension of public health within the Tribe; 2) the creation of a community public health task force; 3) the design of a tribally applicable assessment instrument; and 4) improved collaboration between the Tribe and the scientific community. This project demonstrated that public health assessment in tribal communities is feasible and valuable. Further, the development of a tribally applicable instrument highlights a significant tribal contribution to research and assessment.
Current state of prognostication and risk stratification in myelodysplastic syndromes.
Zeidan, Amer M; Gore, Steven D; Padron, Eric; Komrokji, Rami S
2015-03-01
Myelodysplastic syndromes (MDS) are characterized by significant biologic and clinical heterogeneity. Because of the wide outcome variability, accurate prognostication is vital to high-quality risk-adaptive care of MDS patients. In this review, we discuss the current state of prognostic schemes for MDS and overview efforts aimed at utilizing molecular aberrations for prognostication in clinical practice. Several prognostic instruments have been developed and validated with increasing accuracy and complexity. Oncologists should be aware of the inherent limitations of these prognostic tools as they counsel patients and make clinical decisions. As more therapies are becoming available for MDS, the focus of model development is shifting from prognostic to treatment-specific predictive instruments. In addition to providing additional prognostic data beyond traditional clinical and pathologic parameters, the improved understanding of the genetic landscape and pathophysiologic consequences in MDS may allow the construction of treatment-specific predictive instruments. How to best use the results of molecular mutation testing to inform clinical decision making in MDS is still a work in progress. Important steps in this direction include standardization in performance and interpretation of assays and better understanding of the independent prognostic importance of the recurrent mutations, especially the less frequent ones.
Junghaenel, Doerte U; Schneider, Stefan; Stone, Arthur A; Christodoulou, Christopher; Broderick, Joan E
2014-04-01
This study examined the ecological validity and clinical utility of NIH Patient Reported-Outcomes Measurement Information System (PROMIS®) instruments for anger, depression, and fatigue in women with premenstrual symptoms. One-hundred women completed daily diaries and weekly PROMIS assessments over 4weeks. Weekly assessments were administered through Computerized Adaptive Testing (CAT). Weekly CATs and corresponding daily scores were compared to evaluate ecological validity. To test clinical utility, we examined if CATs could detect changes in symptom levels, if these changes mirrored those obtained from daily scores, and if CATs could identify clinically meaningful premenstrual symptom change. PROMIS CAT scores were higher in the pre-menstrual than the baseline (ps<.0001) and post-menstrual (ps<.0001) weeks. The correlations between CATs and aggregated daily scores ranged from .73 to .88 supporting ecological validity. Mean CAT scores showed systematic changes in accordance with the menstrual cycle and the magnitudes of the changes were similar to those obtained from the daily scores. Finally, Receiver Operating Characteristic (ROC) analyses demonstrated the ability of the CATs to discriminate between women with and without clinically meaningful premenstrual symptom change. PROMIS CAT instruments for anger, depression, and fatigue demonstrated validity and utility in premenstrual symptom assessment. The results provide encouraging initial evidence of the utility of PROMIS instruments for the measurement of affective premenstrual symptoms. Copyright © 2014 Elsevier Inc. All rights reserved.
Wyld, Melanie; Morton, Rachael Lisa; Hayen, Andrew; Howard, Kirsten; Webster, Angela Claire
2012-01-01
Background Chronic kidney disease (CKD) is a common and costly condition to treat. Economic evaluations of health care often incorporate patient preferences for health outcomes using utilities. The objective of this study was to determine pooled utility-based quality of life (the numerical value attached to the strength of an individual's preference for a specific health outcome) by CKD treatment modality. Methods and Findings We conducted a systematic review, meta-analysis, and meta-regression of peer-reviewed published articles and of PhD dissertations published through 1 December 2010 that reported utility-based quality of life (utility) for adults with late-stage CKD. Studies reporting utilities by proxy (e.g., reported by a patient's doctor or family member) were excluded. In total, 190 studies reporting 326 utilities from over 56,000 patients were analysed. There were 25 utilities from pre-treatment CKD patients, 226 from dialysis patients (haemodialysis, n = 163; peritoneal dialysis, n = 44), 66 from kidney transplant patients, and three from patients treated with non-dialytic conservative care. Using time tradeoff as a referent instrument, kidney transplant recipients had a mean utility of 0.82 (95% CI: 0.74, 0.90). The mean utility was comparable in pre-treatment CKD patients (difference = −0.02; 95% CI: −0.09, 0.04), 0.11 lower in dialysis patients (95% CI: −0.15, −0.08), and 0.2 lower in conservative care patients (95% CI: −0.38, −0.01). Patients treated with automated peritoneal dialysis had a significantly higher mean utility (0.80) than those on continuous ambulatory peritoneal dialysis (0.72; p = 0.02). The mean utility of transplant patients increased over time, from 0.66 in the 1980s to 0.85 in the 2000s, an increase of 0.19 (95% CI: 0.11, 0.26). Utility varied by elicitation instrument, with standard gamble producing the highest estimates, and the SF-6D by Brazier et al., University of Sheffield, producing the lowest estimates. The main limitations of this study were that treatment assignments were not random, that only transplant had longitudinal data available, and that we calculated EuroQol Group EQ-5D scores from SF-36 and SF-12 health survey data, and therefore the algorithms may not reflect EQ-5D scores measured directly. Conclusions For patients with late-stage CKD, treatment with dialysis is associated with a significant decrement in quality of life compared to treatment with kidney transplantation. These findings provide evidence-based utility estimates to inform economic evaluations of kidney therapies, useful for policy makers and in individual treatment discussions with CKD patients. PMID:22984353
An update of commercial infrared sensing and imaging instruments
NASA Technical Reports Server (NTRS)
Kaplan, Herbert
1989-01-01
A classification of infrared sensing instruments by type and application, listing commercially available instruments, from single point thermal probes to on-line control sensors, to high speed, high resolution imaging systems is given. A review of performance specifications follows, along with a discussion of typical thermographic display approaches utilized by various imager manufacturers. An update report on new instruments, new display techniques and newly introduced features of existing instruments is given.
Native Mass Spectrometry in Fragment-Based Drug Discovery.
Pedro, Liliana; Quinn, Ronald J
2016-07-28
The advent of native mass spectrometry (MS) in 1990 led to the development of new mass spectrometry instrumentation and methodologies for the analysis of noncovalent protein-ligand complexes. Native MS has matured to become a fast, simple, highly sensitive and automatable technique with well-established utility for fragment-based drug discovery (FBDD). Native MS has the capability to directly detect weak ligand binding to proteins, to determine stoichiometry, relative or absolute binding affinities and specificities. Native MS can be used to delineate ligand-binding sites, to elucidate mechanisms of cooperativity and to study the thermodynamics of binding. This review highlights key attributes of native MS for FBDD campaigns.
IT Security Standards and Legal Metrology - Transfer and Validation
NASA Astrophysics Data System (ADS)
Thiel, F.; Hartmann, V.; Grottker, U.; Richter, D.
2014-08-01
Legal Metrology's requirements can be transferred into the IT security domain applying a generic set of standardized rules provided by the Common Criteria (ISO/IEC 15408). We will outline the transfer and cross validation of such an approach. As an example serves the integration of Legal Metrology's requirements into a recently developed Common Criteria based Protection Profile for a Smart Meter Gateway designed under the leadership of the Germany's Federal Office for Information Security. The requirements on utility meters laid down in the Measuring Instruments Directive (MID) are incorporated. A verification approach to check for meeting Legal Metrology's requirements by their interpretation through Common Criteria's generic requirements is also presented.
An unambiguous determination of the propagation of a compressional Pc 5 wave
NASA Technical Reports Server (NTRS)
Lin, N.; Mcpherron, R. L.; Kivelson, M. G.; Williams, D. J.
1988-01-01
A compressional Pc5 event observed by the ISEE-1 magnetometer and Medium Energetic Particle Experiment instrument on August 21 and 22, 1978, is examined. The propagation properties of the compressional waves were determined using a technique which utilizes the finite Larmor radius effects in the signature of the multichannel energetic ion detector. It is shown that this technique determines unambiguously the propagation characteristics of the wave in both the azimuthal and the radial directions in the plane perpendicular to the background magnetic field; the results remained valid even though heavy energetic ions with Larmor radii larger than proton Larmor radii were present in the plasma.
An unambiguous determination of the propagation of a compressional Pc 5 wave
NASA Astrophysics Data System (ADS)
Lin, N.; McPherron, R. L.; Kivelson, M. G.; Williams, D. J.
1988-06-01
A compressional Pc5 event observed by the ISEE-1 magnetometer and Medium Energetic Particle Experiment instrument on August 21 and 22, 1978, is examined. The propagation properties of the compressional waves were determined using a technique which utilizes the finite Larmor radius effects in the signature of the multichannel energetic ion detector. It is shown that this technique determines unambiguously the propagation characteristics of the wave in both the azimuthal and the radial directions in the plane perpendicular to the background magnetic field; the results remained valid even though heavy energetic ions with Larmor radii larger than proton Larmor radii were present in the plasma.
Fruetel, Julie A [Livermore, CA; Fiechtner, Gregory J [Bethesda, MD; Kliner, Dahv A. V. [San Ramon, CA; McIlroy, Andrew [Livermore, CA
2009-05-05
The present embodiment describes a miniature, microfluidic, absorption-based sensor to detect proteins at sensitivities comparable to LIF but without the need for tagging. This instrument utilizes fiber-based evanescent-field cavity-ringdown spectroscopy, in combination with faceted prism microchannels. The combination of these techniques will increase the effective absorption path length by a factor of 10.sup.3 to 10.sup.4 (to .about.1-m), thereby providing unprecedented sensitivity using direct absorption. The coupling of high-sensitivity absorption with high-performance microfluidic separation will enable real-time sensing of biological agents in aqueous samples (including aerosol collector fluids) and will provide a general method with spectral fingerprint capability for detecting specific bio-agents.
Sampling phasic dopamine signaling with fast-scan cyclic voltammetry in awake behaving rats
Fortin, SM; Cone, JJ; Ng-Evans, S; McCutcheon, JE; Roitman, MF
2015-01-01
Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique which permits the in vivo measurement of extracellular fluctuations in multiple chemical species. The technique is frequently utilized to sample sub-second (phasic) concentration changes of the neurotransmitter dopamine in awake and behaving rats. Phasic dopamine signaling is implicated in reinforcement, goal-directed behavior, and locomotion and FSCV has been used to investigate how rapid changes in striatal dopamine concentration contribute to these and other behaviors. This unit describes the instrumentation and construction, implantation, and use of necessary components required to sample and analyze dopamine concentration changes in awake rats with FSCV. PMID:25559005
Field and laboratory comparison of PM10 instruments in high winds
USDA-ARS?s Scientific Manuscript database
Instruments capable of measuring PM10 (particulate matter less than or equal to 10µm in aerodynamic diameter) concentrations may vary in performance as a result of different technologies utilized in measuring PM10. Therefore, the performance of five instruments capable of measuring PM10 concentratio...
Complete LabVIEW-Controlled HPLC Lab: An Advanced Undergraduate Experience
ERIC Educational Resources Information Center
Beussman, Douglas J.; Walters, John P.
2017-01-01
Virtually all modern chemical instrumentation is controlled by computers. While software packages are continually becoming easier to use, allowing for more researchers to utilize more complex instruments, conveying some level of understanding as to how computers and instruments communicate is still an important part of the undergraduate…
Hong, Sung-Hyun; Lee, Jae-Yeon; Park, Sun-Kyeong; Nam, Jin Hyun; Song, Hyun Jin; Park, Sun-Young; Lee, Eui-Kyung
2018-05-26
Utility provides a preference for specific health state in economic evaluation, and they obtained from general population could be useful in respect of societal resource allocation. We aimed to investigate the utilities of health states for heart failure (HF), a major and growing public health problem, related to hospitalization and adverse drug effects by interrogating the general Korean population. Five health states for patients with HF were developed based on literature reviews: stable chronic heart failure (SCHF), hospitalization, SCHF + cough, SCHF + hypotension, and SCHF + hyperkalemia. We selected 100 individuals from the general population through quota sampling by age, sex, and region, and conducted face-to-face interviews. We measured utilities for 5 hypothetical health states of HF using both time trade-off (TTO) and EuroQol-5 dimensions-5 levels (EQ-5D-5L). Repeated-measures analysis of variance compared the utilities between all health states for each instrument. To identify the factors affecting the utility, a linear mixed model (LMM) analysis was performed. The mean utility value for SCHF, SCHF + cough, SCHF + hypotension, SCHF + hyperkalemia, and hospitalization was calculated as 0.815, 0.732, 0.646, 0.548, and 0.360, respectively, by using TTO. The respective values using EQ-5D-5L were 0.871, 0.793, 0.710, 0.589, and 0.215. The utilities for HF significantly differed between all health states in each instrument (p < 0.001). In LMM analysis, hospitalization had a significantly negative effect on the utilities of both instruments. The utilities decreased in order of SCHF, SCHF + cough, SCHF + hypotension, SCHF + hyperkalemia, and hospitalization. These results can be useful for decision making in resource allocation for HF interventions.
3D Printed Surgical Instruments: The Design and Fabrication Process.
George, Mitchell; Aroom, Kevin R; Hawes, Harvey G; Gill, Brijesh S; Love, Joseph
2017-01-01
3D printing is an additive manufacturing process allowing the creation of solid objects directly from a digital file. We believe recent advances in additive manufacturing may be applicable to surgical instrument design. This study investigates the feasibility, design and fabrication process of usable 3D printed surgical instruments. The computer-aided design package SolidWorks (Dassault Systemes SolidWorks Corp., Waltham MA) was used to design a surgical set including hemostats, needle driver, scalpel handle, retractors and forceps. These designs were then printed on a selective laser sintering (SLS) Sinterstation HiQ (3D Systems, Rock Hill SC) using DuraForm EX plastic. The final printed products were evaluated by practicing general surgeons for ergonomic functionality and performance, this included simulated surgery and inguinal hernia repairs on human cadavers. Improvements were identified and addressed by adjusting design and build metrics. Repeated manufacturing processes and redesigns led to the creation of multiple functional and fully reproducible surgical sets utilizing the user feedback of surgeons. Iterative cycles including design, production and testing took an average of 3 days. Each surgical set was built using the SLS Sinterstation HiQ with an average build time of 6 h per set. Functional 3D printed surgical instruments are feasible. Advantages compared to traditional manufacturing methods include no increase in cost for increased complexity, accelerated design to production times and surgeon specific modifications.
NASA Technical Reports Server (NTRS)
Hindson, W. S.; Hardy, G. H.; Innis, R. C.
1981-01-01
Flight tests were carried out to assess the feasibility of piloted steep curved, and decelerating approach profiles in powered lift STOL aircraft. Several STOL control concepts representative of a variety of aircraft were evaluated in conjunction with suitably designed flight directions. The tests were carried out in a real navigation environment, employed special electronic cockpit displays, and included the development of the performance achieved and the control utilization involved in flying 180 deg turning, descending, and decelerating approach profiles to landing. The results suggest that such moderately complex piloted instrument approaches may indeed be feasible from a pilot acceptance point of view, given an acceptable navigation environment. Systems with the capability of those used in this experiment can provide the potential of achieving instrument operations on curved, descending, and decelerating landing approaches to weather minima corresponding to CTOL Category 2 criteria, while also providing a means of realizing more efficient operations during visual flight conditions.
NASA Technical Reports Server (NTRS)
Hess, R. A.
1976-01-01
Paramount to proper utilization of electronic displays is a method for determining pilot-centered display requirements. Display design should be viewed fundamentally as a guidance and control problem which has interactions with the designer's knowledge of human psychomotor activity. From this standpoint, reliable analytical models of human pilots as information processors and controllers can provide valuable insight into the display design process. A relatively straightforward, nearly algorithmic procedure for deriving model-based, pilot-centered display requirements was developed and is presented. The optimal or control theoretic pilot model serves as the backbone of the design methodology, which is specifically directed toward the synthesis of head-down, electronic, cockpit display formats. Some novel applications of the optimal pilot model are discussed. An analytical design example is offered which defines a format for the electronic display to be used in a UH-1H helicopter in a landing approach task involving longitudinal and lateral degrees of freedom.
Low Latency DESDynI Data Products for Disaster Response, Resource Management and Other Applications
NASA Technical Reports Server (NTRS)
Doubleday, Joshua R.; Chien, Steve A.; Lou, Yunling
2011-01-01
We are developing onboard processor technology targeted at the L-band SAR instrument onboard the planned DESDynI mission to enable formation of SAR images onboard opening possibilities for near-real-time data products to augment full data streams. Several image processing and/or interpretation techniques are being explored as possible direct-broadcast products for use by agencies in need of low-latency data, responsible for disaster mitigation and assessment, resource management, agricultural development, shipping, etc. Data collected through UAVSAR (L-band) serves as surrogate to the future DESDynI instrument. We have explored surface water extent as a tool for flooding response, and disturbance images on polarimetric backscatter of repeat pass imagery potentially useful for structural collapse (earthquake), mud/land/debris-slides etc. We have also explored building vegetation and snow/ice classifiers, via support vector machines utilizing quad-pol backscatter, cross-pol phase, and a number of derivatives (radar vegetation index, dielectric estimates, etc.). We share our qualitative and quantitative results thus far.
PM2.5 and Carbon Emissions from Prescribed Fire in a Longleaf Pine Ecosystem
NASA Astrophysics Data System (ADS)
Strenfel, S. J.; Clements, C. B.; Hiers, J. K.; Kiefer, C. M.
2008-12-01
Prescribed fires are a frequently utilized land-management tool in the Southeastern US. In order to better characterize emissions and impacts from prescribed fire in longleaf pine ecosystems, in situ data were obtained within the burn perimeter using a 10-m instrumented flux tower. Turbulence and temperature data at 10-m were sampled at 10 Hz using a sonic anemometer and fine-wire thermocouples respectively. Measurements of PM2.5, CO and CO2 emissions were sampled at 10-m within the burn perimeter and PM2.5 and Black Carbon PM2.5 were sampled 0.5 km downwind of the fire front using a 2-m instrumented tripod. Preliminary results indicate PM2.5 and carbon emissions significantly increased during the fire-front passage, and downwind PM concentrations were amplified beyond pre-fire ambient concentrations. In addition, the considerable amount a heat release and flux data gathered from these prescribed fires suggests that near surface atmospheric conditions were directly impacted by increased turbulence generation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hierlemann, A.; Hill, M.; Ricco, A.J.
We have developed instrumentation to enable the combination of surface acoustic wave (SAW) sensor measurements with direct, in-situ molecular spectroscopic measurements to understand the response of the SAW sensors with respect to the interfacial chemistry of surface-confined sensing films interacting with gas-phase analytes. Specifically, the instrumentation and software was developed to perform in-situ Fourier-transform infrared external-reflectance spectroscopy (FTIR-ERS) on operating SAW devices during dosing of their chemically modified surfaces with analytes. By probing the surface with IR spectroscopy during gas exposure, it is possible to understand in unprecedented detail the interaction processes between the sorptive SAW coatings and the gaseousmore » analyte molecules. In this report, we provide details of this measurement system, and also demonstrate the utility of these combined measurements by characterizing the SAW and FTIR-ERS responses of organic thin-film sensor coatings interacting with gas-phase analytes.« less
Demonstration of a Balloon Borne Arc-second Pointer Design
NASA Astrophysics Data System (ADS)
Deweese, K.; Ward, P.
Many designs for utilizing stratospheric balloons as low-cost platforms on which to conduct space science experiments have been proposed throughout the years A major hurdle in extending the range of experiments for which these vehicles are useful has been the imposition of the gondola dynamics on the accuracy with which an instrument can be kept pointed at a celestial target A significant number of scientists have sought the ability to point their instruments with jitter in the arc-second range This paper presents the design and analysis of a stratospheric balloon borne pointing system that is able to meet this requirement The test results of a demonstration prototype of the design with similar ability are also presented Discussion of a high fidelity controller simulation for design analysis is presented The flexibility of the flight train is represented through generalized modal analysis A multiple controller scheme is utilized for coarse and fine pointing Coarse azimuth pointing is accomplished by an established pointing system with extensive flight history residing above the gondola structure A pitch-yaw gimbal mount is used for fine pointing providing orthogonal axes when nominally on target Fine pointing actuation is from direct drive dc motors eliminating backlash problems An analysis of friction nonlinearities and a demonstration of the necessity in eliminating static friction are provided A unique bearing hub design is introduced that eliminates static friction from the system dynamics A control scheme involving linear
Smallsats, Cubesats and Scientific Exploration
NASA Astrophysics Data System (ADS)
Stofan, E. R.
2015-12-01
Smallsats (including Cubesats) have taken off in the aerospace research community - moving beyond simple tools for undergraduate and graduate students and into the mainstream of science research. Cubesats started the "smallsat" trend back in the late 1990's early 2000's, with the first Cubesats launching in 2003. NASA anticipates a number of future benefits from small satellite missions, including lower costs, more rapid development, higher risk tolerance, and lower barriers to entry for universities and small businesses. The Agency's Space Technology Mission Directorate is currently addressing technology gaps in small satellite platforms, while the Science Mission Directorate pursues miniaturization of science instruments. Launch opportunities are managed through the Cubesat Launch Initiative, and the Agency manages these projects as sub-orbital payloads with little program overhead. In this session we bring together scientists and technologists to discuss the current state of the smallsat field. We explore ideas for new investments, new instruments, or new applications that NASA should be investing in to expand the utility of smallsats. We discuss the status of a NASA-directed NRC study on the utility of small satellites. Looking to the future, what does NASA need to invest in now, to enable high impact ("decadal survey" level) science with smallsats? How do we push the envelope? We anticipate smallsats will contribute significantly to a more robust exploration and science program for NASA and the country.
Nuclear Energy Infrastructure Database Description and User’s Manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heidrich, Brenden
In 2014, the Deputy Assistant Secretary for Science and Technology Innovation initiated the Nuclear Energy (NE)–Infrastructure Management Project by tasking the Nuclear Science User Facilities, formerly the Advanced Test Reactor National Scientific User Facility, to create a searchable and interactive database of all pertinent NE-supported and -related infrastructure. This database, known as the Nuclear Energy Infrastructure Database (NEID), is used for analyses to establish needs, redundancies, efficiencies, distributions, etc., to best understand the utility of NE’s infrastructure and inform the content of infrastructure calls. The Nuclear Science User Facilities developed the database by utilizing data and policy direction from amore » variety of reports from the U.S. Department of Energy, the National Research Council, the International Atomic Energy Agency, and various other federal and civilian resources. The NEID currently contains data on 802 research and development instruments housed in 377 facilities at 84 institutions in the United States and abroad. The effort to maintain and expand the database is ongoing. Detailed information on many facilities must be gathered from associated institutions and added to complete the database. The data must be validated and kept current to capture facility and instrumentation status as well as to cover new acquisitions and retirements. This document provides a short tutorial on the navigation of the NEID web portal at NSUF-Infrastructure.INL.gov.« less
A new electronic meter for measuring herbage yield
Donald L. Neal; Lee R. Neal
1965-01-01
A new electronic instrument, called the Heterodyne Vegetation Meter to measure herbage yield and utilization was built and tested. The instrument proved to be reliable and rapid. Further testing will be conducted.
Multiple Subtypes among Vocationally Undecided College Students: A Model and Assessment Instrument.
ERIC Educational Resources Information Center
Jones, Lawrence K.; Chenery, Mary Faeth
1980-01-01
A model of vocational decision status was developed, and an instrument was constructed and used to assess its three dimensions. Results demonstrated the utility of the model, supported the reliability and validity of the instrument, and illustrated the value of viewing vocationally undecided students as multiple subtypes. (Author)
ERIC Educational Resources Information Center
Stone, Lisanne L.; van Daal, Carlijn; van der Maten, Marloes; Engels, Rutger C. M. E.; Janssens, Jan M. A. M.; Otten, Roy
2014-01-01
Background: While child self-reports of psychopathology are increasingly accepted, little standardized instruments are utilized for these practices. The Berkeley Puppet Interview (BPI) is an age-appropriate instrument for self-reports of problem behavior by young children. Objective: Psychometric properties of the Dutch version of the BPI will be…
International Space Station Remote Sensing Pointing Analysis
NASA Technical Reports Server (NTRS)
Jacobson, Craig A.
2007-01-01
This paper analyzes the geometric and disturbance aspects of utilizing the International Space Station for remote sensing of earth targets. The proposed instrument (in prototype development) is SHORE (Station High-Performance Ocean Research Experiment), a multiband optical spectrometer with 15 m pixel resolution. The analysis investigates the contribution of the error effects to the quality of data collected by the instrument. This analysis supported the preliminary studies to determine feasibility of utilizing the International Space Station as an observing platform for a SHORE type of instrument. Rigorous analyses will be performed if a SHORE flight program is initiated. The analysis begins with the discussion of the coordinate systems involved and then conversion from the target coordinate system to the instrument coordinate system. Next the geometry of remote observations from the Space Station is investigated including the effects of the instrument location in Space Station and the effects of the line of sight to the target. The disturbance and error environment on Space Station is discussed covering factors contributing to drift and jitter, accuracy of pointing data and target and instrument accuracies.
SAFARI optical system architecture and design concept
NASA Astrophysics Data System (ADS)
Pastor, Carmen; Jellema, Willem; Zuluaga-Ramírez, Pablo; Arrazola, David; Fernández-Rodriguez, M.; Belenguer, Tomás.; González Fernández, Luis M.; Audley, Michael D.; Evers, Jaap; Eggens, Martin; Torres Redondo, Josefina; Najarro, Francisco; Roelfsema, Peter
2016-07-01
SpicA FAR infrared Instrument, SAFARI, is one of the instruments planned for the SPICA mission. The SPICA mission is the next great leap forward in space-based far-infrared astronomy and will study the evolution of galaxies, stars and planetary systems. SPICA will utilize a deeply cooled 2.5m-class telescope, provided by European industry, to realize zodiacal background limited performance, and high spatial resolution. The instrument SAFARI is a cryogenic grating-based point source spectrometer working in the wavelength domain 34 to 230 μm, providing spectral resolving power from 300 to at least 2000. The instrument shall provide low and high resolution spectroscopy in four spectral bands. Low Resolution mode is the native instrument mode, while the high Resolution mode is achieved by means of a Martin-Pupplet interferometer. The optical system is all-reflective and consists of three main modules; an input optics module, followed by the Band and Mode Distributing Optics and the grating Modules. The instrument utilizes Nyquist sampled filled linear arrays of very sensitive TES detectors. The work presented in this paper describes the optical design architecture and design concept compatible with the current instrument performance and volume design drivers.
NASA Technical Reports Server (NTRS)
Swanson, G. T.; Santos, J. A.; White, T. R.; Bruce, W. E.; Kuhl, C. A.; Wright, H. S.
2017-01-01
Mars 2020 will fly the Mars Entry, Descent, and Landing Instrumentation II (MEDLI2) sensor suite consisting of a total of seventeen instrumented thermal sensor plugs, eight pressure transducers, two heat flux sensors, and one radiometer embedded in the thermal protection system (TPS). Of the MEDLI2 instrumentation, eleven instrumented thermal plugs and seven pressure transducers will be installed on the heatshield of the Mars 2020 vehicle while the rest will be installed on the backshell. The goal of the MEDLI2 instrumentation is to directly inform the large performance uncertainties that contribute to the design and validation of a Mars entry system. A better understanding of the entry environment and TPS performance could lead to reduced design margins enabling a greater payload mass-fraction and smaller landing ellipses. To prove that the MEDLI2 system will not degrade the performance of the Mars 2020 TPS, an Aerothermal Do No Harm (DNH) test series was designed and conducted. Like Mars 2020's predecessor, Mars Science Laboratory (MSL), the heatshield material will be Phenolic Impregnated Carbon Ablator (PICA); the Mars 2020 entry conditions are enveloped by the MSL design environments, therefore the development and qualification testing performed during MEDLI is sufficient to show that the similar MEDLI2 heatshield instrumentation will not degrade PICA performance. However, given that MEDLI did not include any backshell instrumentation, the MEDLI2 team was required to design and execute a DNH test series utilizing the backshell TPS material (SLA-561V) with the intended flight sensor suite. To meet the requirements handed down from Mars 2020, the MEDLI2 DNH test series emphasized the interaction between the MEDLI2 sensors and sensing locations with the surrounding backshell TPS and substrucutre. These interactions were characterized by performing environmental testing of four 12" by 12" test panels, which mimicked the construction of the backshell TPS and the integration of the MEDLI2 sensors as seen in Figure 1. The testing included thermal vacuum/ cycling, random vibration, shock, and arc jet testing. The test panels were fabricated by Lockheed Martin, establishing techniques that will be utilized during the Mars 2020 vehicle installation. Each test panel included one thermal sensor plug (two embedded thermocouples), one heat flux sensor, and multiple pressure port holes for evaluation. This presentation will discuss the planning and execution of the MEDLI2 DNH test series. Selected highlights and results of each environmental test will be presented, and lessons learned will be addressed that will feed forward into the planning for the MEDLI2 flight system certification testing.
NASA Astrophysics Data System (ADS)
Delene, D. J.
2014-12-01
Research aircraft that conduct atmospheric measurements carry an increasing array of instrumentation. While on-board personnel constantly review instrument parameters and time series plots, there are an overwhelming number of items. Furthermore, directing the aircraft flight takes up much of the flight scientist time. Typically, a flight engineer is given the responsibility of reviewing the status of on-board instruments. While major issues like not receiving data are quickly identified during a flight, subtle issues like low but believable concentration measurements may go unnoticed. Therefore, it is critical to review data after a flight in near real time. The Airborne Data Processing and Analysis (ADPAA) software package used by the University of North Dakota automates the post-processing of aircraft flight data. Utilizing scripts to process the measurements recorded by data acquisition systems enables the generation of data files within an hour of flight completion. The ADPAA Cplot visualization program enables plots to be quickly generated that enable timely review of all recorded and processed parameters. Near real time review of aircraft flight data enables instrument problems to be identified, investigated and fixed before conducting another flight. On one flight, near real time data review resulted in the identification of unusually low measurements of cloud condensation nuclei, and rapid data visualization enabled the timely investigation of the cause. As a result, a leak was found and fixed before the next flight. Hence, with the high cost of aircraft flights, it is critical to find and fix instrument problems in a timely matter. The use of a automated processing scripts and quick visualization software enables scientists to review aircraft flight data in near real time to identify potential problems.
White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie
2017-01-01
The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.
Galyean, Anne A; Filliben, James J; Holbrook, R David; Vreeland, Wyatt N; Weinberg, Howard S
2016-11-18
Asymmetric flow field flow fractionation (AF 4 ) has several instrumental factors that may have a direct effect on separation performance. A sensitivity analysis was applied to ascertain the relative importance of AF 4 primary instrument factor settings for the separation of a complex environmental sample. The analysis evaluated the impact of instrumental factors namely, cross flow, ramp time, focus flow, injection volume, and run buffer concentration on the multi-angle light scattering measurement of natural organic matter (NOM) molar mass (MM). A 2 (5-1) orthogonal fractional factorial design was used to minimize analysis time while preserving the accuracy and robustness in the determination of the main effects and interactions between any two instrumental factors. By assuming that separations resulting in smaller MM measurements would be more accurate, the analysis produced a ranked list of effects estimates for factors and interactions of factors based on their relative importance in minimizing the MM. The most important and statistically significant AF 4 instrumental factors were buffer concentration and cross flow. The least important was ramp time. A parallel 2 (5-2) orthogonal fractional factorial design was also employed on five environmental factors for synthetic natural water samples containing silver nanoparticles (NPs), namely: NP concentration, NP size, NOM concentration, specific conductance, and pH. None of the water quality characteristic effects or interactions were found to be significant in minimizing the measured MM; however, the interaction between NP concentration and NP size was an important effect when considering NOM recovery. This work presents a structured approach for the rigorous assessment of AF 4 instrument factors and optimal settings for the separation of complex samples utilizing efficient orthogonal factional factorial design and appropriate graphical analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Skin friction measurement in complex flows using thin oil film techniques
NASA Technical Reports Server (NTRS)
1994-01-01
The NASA Grant NAG2-261 was initiated to support a program of research to study complex flows that occur in flight and laboratory experiments by building, testing and optimizing an on-board technique for direct measurement of surface shear stress using thin oil film techniques. The program of research has proceeded under the supervision of the NASA Ames Research Center and with further cooperation from the NASA Ames-Dryden and NASA Langley Research Centers. In accordance with the original statement of work, the following research milestones were accomplished: (1) design and testing of an internally mounted one-directional skin friction meter to demonstrate the feasibility of the concept; (2) design and construction of a compact instrument capable of measuring skin friction in two directions; (3) study of transitional and fully turbulent boundary layers over a flat plate with and without longitudinal pressure gradients utilizing the compact two-directional skin friction meter; (4) study of the interaction between a turbulent boundary layer and a shock wave generated by a compression corner using the two-directional meter; and (5) flight qualification of the compact meter and accompanying electronic and pneumatic systems, preliminary installation into flight test fixture.
Advanced Instrumentation for Ultrafast Science at the LCLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berrah, Nora
2015-10-13
This grant supported a Single Investigator and Small Group Research (SISGR) application to enable multi-user research in Ultrafast Science using the Linac Coherent Light Source (LCLS), the world’s first hard x-ray free electron laser (FEL) which lased for the first time at 1.5 Å on April 20, 2009. The goal of our proposal was to enable a New Era of Science by requesting funds to purchase and build Advanced Instrumentation for Ultrafast Science (AIUS), to utilize the intense, short x-ray pulses produced by the LCLS. The proposed instrumentation will allow peer review selected users to probe the ultrasmall and capture themore » ultrafast. These tools will expand on the investment already made in the construction of the light source and its instrumentation in both the LCLS and LUSI projects. The AIUS will provide researchers in the AMO, Chemical, Biological and Condensed Matter communities with greater flexibility in defining their scientific agenda at the LCLS. The proposed instrumentation will complement and significantly augment the present AMO instrument (funded through the LCLS project) through detectors and capabilities not included in the initial suite of instrumentation at the facility. We have built all of the instrumentations and they have been utilized by scientists. Please see report attached.« less
Massey, J K
1979-01-01
The increasing usage of electronic instruments in health care systems invariably leads to some level of dependence on them. In order to maximize the utility of these tools a high degree of reliability is essential. Many of the failures being experienced in systems where electronic instruments are being utilized may be attributed not to a failure of the instrument itself but rather to the poor quality of the commercial power to which they are attached. In order to reduce the effects of power fluctuations and outages, some type of power protection equipment must be installed between the commercial power system and the instrument. This article discusses the types of "electronic noise" present on commercial power lines and the various types of equipment used to reduce its effect on electronic instrumentation. In general, the Uninterruptible Power System (UPS) is shown to be the most effective power buffering element for a health care environment. General terminology associated with specifications of a UPS is defined in the article and attached appendix.
Fiber optic interferometry for industrial process monitoring and control applications
NASA Astrophysics Data System (ADS)
Marcus, Michael A.
2002-02-01
Over the past few years we have been developing applications for a high-resolution (sub-micron accuracy) fiber optic coupled dual Michelson interferometer-based instrument. It is being utilized in a variety of applications including monitoring liquid layer thickness uniformity on coating hoppers, film base thickness uniformity measurement, digital camera focus assessment, optical cell path length assessment and imager and wafer surface profile mapping. The instrument includes both coherent and non-coherent light sources, custom application dependent optical probes and sample interfaces, a Michelson interferometer, custom electronics, a Pentium-based PC with data acquisition cards and LabWindows CVI or LabView based application specific software. This paper describes the development evolution of this instrument platform and applications highlighting robust instrument design, hardware, software, and user interfaces development. The talk concludes with a discussion of a new high-speed instrument configuration, which can be utilized for high speed surface profiling and as an on-line web thickness gauge.
NASA's Space Launch System (SLS) Program: Mars Program Utilization
NASA Technical Reports Server (NTRS)
May, Todd A.; Creech, Stephen D.
2012-01-01
NASA's Space Launch System is being designed for safe, affordable, and sustainable human and scientific exploration missions beyond Earth's orbit (BEO), as directed by the NASA Authorization Act of 2010 and NASA's 2011 Strategic Plan. This paper describes how the SLS can dramatically change the Mars program's science and human exploration capabilities and objectives. Specifically, through its high-velocity change (delta V) and payload capabilities, SLS enables Mars science missions of unprecedented size and scope. By providing direct trajectories to Mars, SLS eliminates the need for complicated gravity-assist missions around other bodies in the solar system, reducing mission time, complexity, and cost. SLS's large payload capacity also allows for larger, more capable spacecraft or landers with more instruments, which can eliminate the need for complex packaging or "folding" mechanisms. By offering this capability, SLS can enable more science to be done more quickly than would be possible through other delivery mechanisms using longer mission times.
Uniaxial Compressive Strengths of Rocks Drilled at Gale Crater, Mars
NASA Astrophysics Data System (ADS)
Peters, G. H.; Carey, E. M.; Anderson, R. C.; Abbey, W. J.; Kinnett, R.; Watkins, J. A.; Schemel, M.; Lashore, M. O.; Chasek, M. D.; Green, W.; Beegle, L. W.; Vasavada, A. R.
2018-01-01
Measuring the physical properties of geological materials is important for understanding geologic history. Yet there has never been an instrument with the purpose of measuring mechanical properties of rocks sent to another planet. The Mars Science Laboratory (MSL) rover employs the Powder Acquisition Drill System (PADS), which provides direct mechanical interaction with Martian outcrops. While the objective of the drill system is not to make scientific measurements, the drill's performance is directly influenced by the mechanical properties of the rocks it drills into. We have developed a methodology that uses the drill to indicate the uniaxial compressive strengths of rocks through comparison with performance of an identically assembled drill system in terrestrial samples of comparable sedimentary class. During this investigation, we utilize engineering data collected on Mars to calculate the percussive energy needed to maintain a prescribed rate of penetration and correlate that to rock strength.
Extending single molecule fluorescence observation time by amplitude-modulated excitation
Kisley, Lydia; Chang, Wei-Shun; Cooper, David; Mansur, Andrea P; Landes, Christy F
2014-01-01
We present a hardware-based method that can improve single molecule fluorophore observation time by up to 1500% and super-localization by 47% for the experimental conditions used. The excitation was modulated using an acousto-optic modulator (AOM) synchronized to the data acquisition and inherent data conversion time of the detector. The observation time and precision in super-localization of four commonly used fluorophores were compared under modulated and traditional continuous excitation, including direct total internal reflectance excitation of Alexa 555 and Cy3, non-radiative Förster resonance energy transfer (FRET) excited Cy5, and direct epi-fluorescence wide field excitation of Rhodamine 6G. The proposed amplitude-modulated excitation does not perturb the chemical makeup of the system or sacrifice signal and is compatible with multiple types of fluorophores. Amplitude-modulated excitation has practical applications for any fluorescent study utilizing an instrumental setup with time-delayed detectors. PMID:24587894
Hawthorne, Graeme
2009-09-01
As researchers seek to include clinical outcomes, the health-related quality of life (HRQoL) of participants and meet economic evaluation demands, they are confronted with collecting disparate outcome data where parsimony is imperative. This study addressed this through construction of a short HRQoL measure, the Assessment of Quality of Life (AQoL)-8 from the original AQoL. Data from the AQoL validation database (N = 996) were reanalyzed using item response theory (IRT) to identify the least fitting items, which were removed. The standard AQoL scoring algorithm and weights were applied. Validity, reliability, and sensitivity tests were carried out using the 2004 South Australian Health Omnibus Survey (N = 3015), including direct comparisons with other short utility measures, the EQ5D and SF6D. The IRT analysis showed that the AQoL was a weak scale (Loevinger H = 0.36) but reliable (Mokken rho = 0.84). Removal of the four weakest items led to an 8-item instrument with two items per subscale, the AQoL-8. The AQoL-8 Loevinger H = 0.38 and Mokken rho = 0.80 suggested similar psychometric properties to the AQoL. It correlated (intraclass correlation coefficient) 0.95 (or 90% of shared variance) with the AQoL. The AQoL-8 was as sensitive to six common health conditions as the AQoL, EQ5D, and SF6D. The utility scores fall on the same life-death scale as those of the AQoL. Where parsimony is imperative, researchers may consider use of the AQoL-8 to collect participant self-report HRQoL data that is suitable for use either as reported outcomes or for the calculation of quality-adjusted life-years for cost-utility analysis.
NASA Astrophysics Data System (ADS)
Hollister, Matthew I.; Czakon, Nicole G.; Day, Peter K.; Downes, Thomas P.; Duan, Ran; Gao, Jiansong; Glenn, Jason; Golwala, Sunil R.; LeDuc, Henry G.; Maloney, Philip R.; Mazin, Benjamin A.; Nguyen, Hien Trong; Noroozian, Omid; Sayers, Jack; Schlaerth, James; Siegel, Seth; Vaillancourt, John E.; Vayonakis, Anastasios; Wilson, Philip; Zmuidzinas, Jonas
2010-07-01
MUSIC (Multicolor Submillimeter kinetic Inductance Camera) is a new facility instrument for the Caltech Submillimeter Observatory (Mauna Kea, Hawaii) developed as a collaborative effect of Caltech, JPL, the University of Colorado at Boulder and UC Santa Barbara, and is due for initial commissioning in early 2011. MUSIC utilizes a new class of superconducting photon detectors known as microwave kinetic inductance detectors (MKIDs), an emergent technology that offers considerable advantages over current types of detectors for submillimeter and millimeter direct detection. MUSIC will operate a focal plane of 576 spatial pixels, where each pixel is a slot line antenna coupled to multiple detectors through on-chip, lumped-element filters, allowing simultaneously imaging in four bands at 0.86, 1.02, 1.33 and 2.00 mm. The MUSIC instrument is designed for closed-cycle operation, combining a pulse tube cooler with a two-stage Helium-3 adsorption refrigerator, providing a focal plane temperature of 0.25 K with intermediate temperature stages at approximately 50, 4 and 0.4 K for buffering heat loads and heat sinking of optical filters. Detector readout is achieved using semi-rigid coaxial cables from room temperature to the focal plane, with cryogenic HEMT amplifiers operating at 4 K. Several hundred detectors may be multiplexed in frequency space through one signal line and amplifier. This paper discusses the design of the instrument cryogenic hardware, including a number of features unique to the implementation of superconducting detectors. Predicted performance data for the instrument system will also be presented and discussed.
Mathur, Gagan; Haugen, Thomas H; Davis, Scott L; Krasowski, Matthew D
2014-01-01
Interfacing of clinical laboratory instruments with the laboratory information system (LIS) via "middleware" software is increasingly common. Our clinical laboratory implemented capillary electrophoresis using a Sebia(®) Capillarys-2™ (Norcross, GA, USA) instrument for serum and urine protein electrophoresis. Using Data Innovations Instrument Manager, an interface was established with the LIS (Cerner) that allowed for bi-directional transmission of numeric data. However, the text of the interpretive pathology report was not properly transferred. To reduce manual effort and possibility for error in text data transfer, we developed scripts in AutoHotkey, a free, open-source macro-creation and automation software utility. Scripts were written to create macros that automated mouse and key strokes. The scripts retrieve the specimen accession number, capture user input text, and insert the text interpretation in the correct patient record in the desired format. The scripts accurately and precisely transfer narrative interpretation into the LIS. Combined with bar-code reading by the electrophoresis instrument, the scripts transfer data efficiently to the correct patient record. In addition, the AutoHotKey script automated repetitive key strokes required for manual entry into the LIS, making protein electrophoresis sign-out easier to learn and faster to use by the pathology residents. Scripts allow for either preliminary verification by residents or final sign-out by the attending pathologist. Using the open-source AutoHotKey software, we successfully improved the transfer of text data between capillary electrophoresis software and the LIS. The use of open-source software tools should not be overlooked as tools to improve interfacing of laboratory instruments.
Ehlers, Justis P; Srivastava, Sunil K; Feiler, Daniel; Noonan, Amanda I; Rollins, Andrew M; Tao, Yuankai K
2014-01-01
To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated.
Nuclear Energy Infrastructure Database Fitness and Suitability Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heidrich, Brenden
In 2014, the Deputy Assistant Secretary for Science and Technology Innovation (NE-4) initiated the Nuclear Energy-Infrastructure Management Project by tasking the Nuclear Science User Facilities (NSUF) to create a searchable and interactive database of all pertinent NE supported or related infrastructure. This database will be used for analyses to establish needs, redundancies, efficiencies, distributions, etc. in order to best understand the utility of NE’s infrastructure and inform the content of the infrastructure calls. The NSUF developed the database by utilizing data and policy direction from a wide variety of reports from the Department of Energy, the National Research Council, themore » International Atomic Energy Agency and various other federal and civilian resources. The NEID contains data on 802 R&D instruments housed in 377 facilities at 84 institutions in the US and abroad. A Database Review Panel (DRP) was formed to review and provide advice on the development, implementation and utilization of the NEID. The panel is comprised of five members with expertise in nuclear energy-associated research. It was intended that they represent the major constituencies associated with nuclear energy research: academia, industry, research reactor, national laboratory, and Department of Energy program management. The Nuclear Energy Infrastructure Database Review Panel concludes that the NSUF has succeeded in creating a capability and infrastructure database that identifies and documents the major nuclear energy research and development capabilities across the DOE complex. The effort to maintain and expand the database will be ongoing. Detailed information on many facilities must be gathered from associated institutions added to complete the database. The data must be validated and kept current to capture facility and instrumentation status as well as to cover new acquisitions and retirements.« less
Development of Processing Techniques for Advanced Thermal Protection Materials
NASA Technical Reports Server (NTRS)
Selvaduray, Guna; Cox, Michael; Srinivasan, Vijayakumar
1997-01-01
Thermal Protection Materials Branch (TPMB) has been involved in various research programs to improve the properties and structural integrity of the existing aerospace high temperature materials. Specimens from various research programs were brought into the analytical laboratory for the purpose of obtaining and refining the material characterization. The analytical laboratory in TPMB has many different instruments which were utilized to determine the physical and chemical characteristics of materials. Some of the instruments that were utilized by the SJSU students are: Scanning Electron Microscopy (SEM), Energy Dispersive X-ray analysis (EDX), X-ray Diffraction Spectrometer (XRD), Fourier Transform-Infrared Spectroscopy (FTIR), Ultra Violet Spectroscopy/Visible Spectroscopy (UV/VIS), Particle Size Analyzer (PSA), and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES). The above mentioned analytical instruments were utilized in the material characterization process of the specimens from research programs such as: aerogel ceramics (I) and (II), X-33 Blankets, ARC-Jet specimens, QUICFIX specimens and gas permeability of lightweight ceramic ablators. In addition to analytical instruments in the analytical laboratory at TPMB, there are several on-going experiments. One particular experiment allows the measurement of permeability of ceramic ablators. From these measurements, physical characteristics of the ceramic ablators can be derived.
2012-01-01
Background Multi attribute utility (MAU) instruments are used to include the health related quality of life (HRQoL) in economic evaluations of health programs. Comparative studies suggest different MAU instruments measure related but different constructs. The objective of this paper is to describe the methods employed to achieve content validity in the descriptive system of the Assessment of Quality of Life (AQoL)-6D, MAU instrument. Methods The AQoL program introduced the use of psychometric methods in the construction of health related MAU instruments. To develop the AQoL-6D we selected 112 items from previous research, focus groups and expert judgment and administered them to 316 members of the public and 302 hospital patients. The search for content validity across a broad spectrum of health states required both formative and reflective modelling. We employed Exploratory Factor Analysis and Structural Equation Modelling (SEM) to meet these dual requirements. Results and Discussion The resulting instrument employs 20 items in a multi-tier descriptive system. Latent dimension variables achieve sensitive descriptions of 6 dimensions which, in turn, combine to form a single latent QoL variable. Diagnostic statistics from the SEM analysis are exceptionally good and confirm the hypothesised structure of the model. Conclusions The AQoL-6D descriptive system has good psychometric properties. They imply that the instrument has achieved construct validity and provides a sensitive description of HRQoL. This means that it may be used with confidence for measuring health related quality of life and that it is a suitable basis for modelling utilities for inclusion in the economic evaluation of health programs. PMID:22507254
Richardson, Jeffrey R J; Peacock, Stuart J; Hawthorne, Graeme; Iezzi, Angelo; Elsworth, Gerald; Day, Neil A
2012-04-17
Multi attribute utility (MAU) instruments are used to include the health related quality of life (HRQoL) in economic evaluations of health programs. Comparative studies suggest different MAU instruments measure related but different constructs. The objective of this paper is to describe the methods employed to achieve content validity in the descriptive system of the Assessment of Quality of Life (AQoL)-6D, MAU instrument. The AQoL program introduced the use of psychometric methods in the construction of health related MAU instruments. To develop the AQoL-6D we selected 112 items from previous research, focus groups and expert judgment and administered them to 316 members of the public and 302 hospital patients. The search for content validity across a broad spectrum of health states required both formative and reflective modelling. We employed Exploratory Factor Analysis and Structural Equation Modelling (SEM) to meet these dual requirements. The resulting instrument employs 20 items in a multi-tier descriptive system. Latent dimension variables achieve sensitive descriptions of 6 dimensions which, in turn, combine to form a single latent QoL variable. Diagnostic statistics from the SEM analysis are exceptionally good and confirm the hypothesised structure of the model. The AQoL-6D descriptive system has good psychometric properties. They imply that the instrument has achieved construct validity and provides a sensitive description of HRQoL. This means that it may be used with confidence for measuring health related quality of life and that it is a suitable basis for modelling utilities for inclusion in the economic evaluation of health programs.
ERIC Educational Resources Information Center
Henry, Beverly W.; Smith, Thomas J.
2010-01-01
Objective: To develop an instrument to assess client-centered counseling behaviors (skills) of student-counselors in a standardized patient (SP) exercise. Methods: Descriptive study of the accuracy and utility of a newly developed counseling evaluation instrument. Study participants included 11 female student-counselors at a Midwestern…
Jonathan W. Amy and the Amy Facility for Instrumentation Development.
Cooks, R Graham
2017-05-16
This Perspective describes the unique Jonathan Amy Facility for Chemical Instrumentation in the Department of Chemistry at Purdue University, tracing its history and mode of operation. It also describes aspects of the career of its namesake and some of his insights which have been central to analytical instrumentation development, improvement, and utilization, both at Purdue and nationally.
Approaches of High School Instrumental Music Educators in Response to Student Challenges
ERIC Educational Resources Information Center
Edgar, Scott N.
2016-01-01
The purpose of this multiple instrumental case study was to explore approaches of four high school instrumental music educators assuming the role of facilitative teacher in responding to challenges affecting the social and emotional well-being of their students. This study utilized the framework of social emotional learning as a lens to view the…
Wideband Instrument for Snow Measurements (WISM)
NASA Technical Reports Server (NTRS)
Miranda, Felix A.
2015-01-01
This presentation provides a brief summary of the utility of a wideband active and passive (radar and radiometer, respectively) instrument (8-40 GHz) to support the snow science community. The effort seeks to improve snow measurements through advanced calibration and expanded frequency of active and passive sensors and to demonstrate their science utility through airborne retrievals of snow water equivalent (SWE). In addition the effort seeks to advance the technology readiness of broadband current sheet array (CSA) antenna technology for spaceflight applications.
Hsu, Ya-Chuan
2011-09-01
: Diverse social and recreational activities in elder care institutions have been provided to enrich a person's mental well-being amidst what is a relatively monotonous life. However, few instruments that measure the social activities of long-term care residents are available. : This study was designed to develop a culturally sensitive instrument (Socially Supportive Activity Inventory, SSAI) to assess quantity and quality of social activities for long-term care institutions and validate the instrument's psychometric properties. : The SSAI was developed on the basis of the social support theory, a synthesis of literature, and Taiwanese cultural mores. The instrument was rigorously subjected to a two-stage process to evaluate its reliability and validity. In Stage 1, six experts from diverse backgrounds were recruited to evaluate instrument items and estimate the content validity of the instrument using a content validity questionnaire. Items were modified and refined on the basis of the responses of the expert panel and a set of criteria. After obtaining approval from a university institutional review board, in the second stage of evaluating test-retest reliability, a convenience sample of 10 Taiwanese institutionalized elders in a pilot study, recruited from a nursing home, completed the revised instrument at two separate times over 2 weeks. : Results showed a content validity of .96. Test-retest reliability from a sample of 10 participants yielded stability coefficients of .76-1.00. The stability coefficient was 1.00 for the component of frequency, .76-1.00 for the component of meaningfulness, and .78-1.00 for the component of enjoyment. : The SSAI is a highly relevant and reliable culturally based instrument that can measure social activity in long-term care facilities. Because of the pilot nature of this study, future directions include further exploration of the SSAI instrument's psychometric properties. This should be done by enlarging the sample size to include more long-term care facilities and individual participants. Future studies can utilize diverse measures of social activity for comparison and validation of the SSAI.
Pluimers, Dorine J; van Vliet, Ellen J; Niezink, Anne Gh; van Mourik, Martijn S; Eddes, Eric H; Wouters, Michel W; Tollenaar, Rob A E M; van Harten, Wim H
2015-04-09
To analyze the organization of multidisciplinary care pathways such as colorectal cancer care, an instrument was developed based on a recently published framework that was earlier used in analyzing (monodisciplinary) specialist cataract care from a lean perspective. The instrument was constructed using semi-structured interviews and direct observation of the colorectal care process based on a Rapid Plant Assessment. Six lean aspects that were earlier established that highly impact process design, were investigated: operational focus, autonomous work cell, physical lay-out of resources, multi-skilled team, pull planning and non-value adding activities. To test reliability, clarity and face validity of the instrument, a pilot study was performed in eight Dutch hospitals. In the pilot it proved feasible to apply the instrument and generate the intended information. The instrument consisted of 83 quantitative and 24 qualitative items. Examples of results show differences in operational focus, number of patient visits needed for diagnosis, numbers of staff involved with treatment, the implementation of protocols and utilization of one-stop-shops. Identification of waste and non-value adding activities may need further attention. Based on feedback from involved clinicians the face validity was acceptable and the results provided useful feedback- and benchmark data. The instrument proved to be reliable and valid for broader implementation in Dutch health care. The limited number of cases made statistical analysis not possible and further validation studies may shed better light on variation. This paper demonstrates the use of an instrument to analyze organizational characteristics in colorectal cancer care from a lean perspective. Wider use might help to identify best organizational practices for colorectal surgery. In larger series the instrument might be used for in-depth research into the relation between organization and patient outcomes. Although we found no reason to adapt the underlying framework, recommendations were made for further development to enable use in different tumor- and treatment modalities and in larger (international) samples that allow for more advanced statistical analysis. Waste from defective care or from wasted human potential will need further elaboration of the instrument.
Space Telescope Design to Directly Image the Habitable Zone of Alpha Centauri
NASA Technical Reports Server (NTRS)
Bendek, Eduardo A.; Belikov, Ruslan; Lozi, Julien; Thomas, Sandrine; Males, Jared; Weston, Sasha; McElwain, Michael
2015-01-01
The scientific interest in directly imaging and identifying Earth-like planets within the Habitable Zone (HZ) around nearby stars is driving the design of specialized direct imaging missions such as ACESAT, EXO-C, EXO-S and AFTA-C. The inner edge of Alpha Cen A&B Habitable Zone is found at exceptionally large angular separations of 0.7" and 0.4" respectively. This enables direct imaging of the system with a 0.3m class telescope. Contrast ratios on the order of 10(exp 10) are needed to image Earth-brightness planets. Low-resolution (5-band) spectra of all planets may allow establishing the presence and amount of an atmosphere. This star system configuration is optimal for a specialized small, and stable space telescope that can achieve high-contrast but has limited resolution. This paper describes an innovative instrument design and a mission concept based on a full Silicon Carbide off-axis telescope, which has a Phase Induced Amplitude Apodization coronagraph embedded in the telescope. This architecture maximizes stability and throughput. A Multi-Star Wave Front algorithm is implemented to drive a deformable mirror controlling simultaneously diffracted light from the on-axis and binary companion star. The instrument has a Focal Plane Occulter to reject starlight into a high precision pointing control camera. Finally we utilize a Orbital Differential Imaging (ODI) post-processing method that takes advantage of a highly stable environment (Earth-trailing orbit) and a continuous sequence of images spanning 2 years, to reduce the final noise floor in post processing to approximately 2e-11 levels, enabling high confidence and at least 90% completeness detections of Earth-like planets.
Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space
NASA Technical Reports Server (NTRS)
Krasowski, Michael J.; Prokop, Norman F.
2010-01-01
This innovation represents a method and circuit realization of a system designed to make in-situ measurements of test solar-cell operational parameters on orbit using readily available high-temperature and high-ionizing-radiation- tolerant electronic components. This innovation enables on-orbit in-situ solar-array health monitoring and is in response to a need recognized by the U.S. Air Force for future solar arrays for unmanned spacecraft. This system can also be constructed out of commercial-grade electronics and can be embedded into terrestrial solar power system as a diagnostics instrument. This innovation represents a novel approach to I-V curve measurement that is radiation and temperature hard, consumes very few system resources, is economical, and utilizes commercially available components. The circuit will also operate at temperatures as low as 55 C and up to +225 C, allowing it to reside close to the array in direct sunlight. It uses a swept mode transistor functioning as a resistive load while utilizing the solar cells themselves as the biasing device, so the size of the instrument is small and there is no danger of over-driving the cells. Further, this innovation utilizes nearly universal spacecraft bus resources and therefore can be readily adapted to any spacecraft bus allowing for ease of retrofit, or designed into new systems without requiring the addition of infrastructure. One unique characteristic of this innovation is that it effects the measurement of I-V curves without the use of large resistor arrays or active current sources normally used to characterize cells. A single transistor is used as a variable resistive load across the cell. This multi-measurement instrument was constructed using operational amplifiers, analog switches, voltage regulators, MOSFETs, resistors, and capacitors. The operational amplifiers, analog switches, and voltage regulators are silicon-on-insulator (SOI) technology known for its hardness to the effects of ionizing radiation. The SOI components used can tolerate temperatures up to 225 C, which gives plenty of thermal headroom allowing this circuit to perhaps reside in the solar cell panel itself where temperatures can reach over 100 C.
Improved integrated real-time contamination monitor. [with photomutliplier tube
NASA Technical Reports Server (NTRS)
1974-01-01
The laboratory model of the ITREM including the photomultiplier is described along with the utilization of the instrument. The preliminary designs are reviewed, and the development of the optical module for the instrument is discussed.
Bradford, Sally; Rickwood, Debra
2012-01-01
Adolescence and young adulthood are often turbulent periods in a person’s life. There are high rates of accidental deaths, suicide, mental health concerns, substance use, and sexual experimentation. Health care professionals need to conduct holistic assessments of clients in these developmental life stages to identify psychosocial risks and provide targeted early intervention and implement prevention strategies. The most useful psychosocial assessments for most health care professionals are those that can provide a complete picture of the young person’s life and circumstances. This article identifies psychosocial assessment instruments that can be used as an initial assessment and engagement tool with the general population of young people presenting for health care. We review the psychometric properties of each of the instruments, determining what type of instrument is most acceptable to young people, whether any can increase disclosure and improve engagement between young people and health professionals, and whether they have predictive utility. The search strategy complied with the relevant sections of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. A total of 89 published articles were identified, covering 31 different assessment instruments. Results indicated that those that were self-administered were most acceptable to young people, although it is unclear whether pen-and-paper or computer formats were preferred. Most psychosocial assessments can improve rates of disclosure and enhance engagement between young people and health professionals; however, worryingly, we found evidence that clinicians did not always respond to some of the most serious identified risks. Only for one instrument was there any mention of predictive utility. Future research should employ longitudinal approaches to determine the predictive utility of psychosocial assessments and focus on whether the use of new technologies can improve rates of disclosure. PMID:24600292
Wolstenholme, Jane L; Bargo, Danielle; Wang, Kay; Harnden, Anthony; Räisänen, Ulla; Abel, Lucy
2018-03-21
No current guidance is available in the UK on the choice of preference-based measure (PBM) that should be used in obtaining health-related quality of life from children. The aim of this study is to review the current usage of PBMs for obtaining health state utility values in child and adolescent populations, and to obtain information on patient and parent-proxy respondent preferences in completing PBMs in the UK. A literature review was conducted to determine which instrument is most frequently used for child-based economic evaluations and whether child or proxy responses are used. Instruments were compared on dimensions, severity levels, elicitation and valuation methods, availability of value sets and validation studies, and the range of utility values generated. Additionally, a series of focus groups of parents and young people (11-20 years) were convened to determine patient and proxy preferences. Five PBMs suitable for child populations were identified, although only the Health Utilities Index 2 (HUI2) and Child Heath Utility 9D (CHU-9D) have UK value sets. 45 papers used PBMs in this population, but many used non-child-specific PBMs. Most respondents were parent proxies, even in adolescent populations. Reported missing data ranged from 0.5 to 49.3%. The focus groups reported their experiences with the EQ-5D-Y and CHU-9D. Both the young persons' group and parent/proxy groups felt that the CHU-9D was more comprehensive but may be harder for a proxy to complete. Some younger children had difficulty understanding the CHU-9D questions, but the young persons' group nonetheless preferred responding directly. The use of PBMs in child populations is increasing, but many studies use PBMs that do not have appropriate value sets. Parent proxies are the most common respondents, but the focus group responses suggest it would be preferred, and may be more informative, for older children to self-report or for child-parent dyads to respond.
Accommodating subject and instrument variations in spectroscopic determinations
Haas, Michael J [Albuquerque, NM; Rowe, Robert K [Corrales, NM; Thomas, Edward V [Albuquerque, NM
2006-08-29
A method and apparatus for measuring a biological attribute, such as the concentration of an analyte, particularly a blood analyte in tissue such as glucose. The method utilizes spectrographic techniques in conjunction with an improved instrument-tailored or subject-tailored calibration model. In a calibration phase, calibration model data is modified to reduce or eliminate instrument-specific attributes, resulting in a calibration data set modeling intra-instrument or intra-subject variation. In a prediction phase, the prediction process is tailored for each target instrument separately using a minimal number of spectral measurements from each instrument or subject.
Investigation of Cloud Properties and Atmospheric Profiles with MODIS
NASA Technical Reports Server (NTRS)
Menzel, Paul; Ackerman, Steve; Moeller, Chris; Gumley, Liam; Strabala, Kathy; Frey, Richard; Prins, Elaine; LaPorte, Dan; Wolf, Walter
1997-01-01
The WINter Cloud Experiment (WINCE) was directed and supported by personnel from the University of Wisconsin in January and February. Data sets of good quality were collected by the MODIS Airborne Simulator (MAS) and other instruments on the NASA ER2; they will be used to develop and validate cloud detection and cloud property retrievals over winter scenes (especially over snow). Software development focused on utilities needed for all of the UW product executables; preparations for Version 2 software deliveries were almost completed. A significant effort was made, in cooperation with SBRS and MCST, in characterizing and understanding MODIS PFM thermal infrared performance; crosstalk in the longwave infrared channels continues to get considerable attention.
Sampling phasic dopamine signaling with fast-scan cyclic voltammetry in awake, behaving rats.
Fortin, S M; Cone, J J; Ng-Evans, S; McCutcheon, J E; Roitman, M F
2015-01-05
Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique that permits the in vivo measurement of extracellular fluctuations in multiple chemical species. The technique is frequently utilized to sample sub-second (phasic) concentration changes of the neurotransmitter dopamine in awake and behaving rats. Phasic dopamine signaling is implicated in reinforcement, goal-directed behavior, and locomotion, and FSCV has been used to investigate how rapid changes in striatal dopamine concentration contribute to these and other behaviors. This unit describes the instrumentation and construction, implantation, and use of components required to sample and analyze dopamine concentration changes in awake rats with FSCV. Copyright © 2015 John Wiley & Sons, Inc.
Impact of Lean on surgical instrument reduction: Less is more.
Wannemuehler, Todd J; Elghouche, Alhasan N; Kokoska, Mimi S; Deig, Christopher R; Matt, Bruce H
2015-12-01
To determine whether instrument sets that are frequently used by multiple surgeons can be substantially reduced in size with consensus. Prospective quality improvement study using Lean Six Sigma for purposeful and consensual reduction of non-value-added instruments in adenotonsillectomy instrument sets. Value stream mapping was utilized to determine instrumentation usage and reprocessing workflow. Preintervention instrument utilization surveys allowed consensual and intelligent set reduction. Non-value-added instruments were targeted for waste elimination by placement in a supplemental set. Times for pre- and postintervention instrument assembly, Mayo setup, and surgery were collected for adenotonsillectomies. Postintervention satisfaction surveys of surgeons and staff were conducted. Adenotonsillectomy sets were reduced from 52 to 24 instruments. Median assembly times were significantly reduced from 8.4 to 4.7 minutes (P < .0001) with a set assembly cost reduction of 44%. Following natural log transformations, mean Mayo setup times were significantly reduced from 97.6 to 76.1 seconds (P < .0001), and mean operative times were not significantly affected (1,773 vs. 1,631 seconds, P > .05). The supplemental set was opened in only 3.6% of cases. Satisfaction was >90% regarding the intervention. Set build cost was reduced by $1,468.99 per set. Lean Six Sigma improves efficiency and reduces waste by empowering team members to improve their environment. Instrument set reduction is ideal for waste elimination because of tool accumulation over time and instrument obsolescence as newer technologies are adopted. Similar interventions could easily be applied to larger sinus, mastoidectomy, and spine sets. NA. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
The NASA Micro-Pulse Lidar Network (MPLNET): Co-location of Lidars with AERONET
NASA Technical Reports Server (NTRS)
Welton, Ellsworth J.; Campbell, James R.; Berkoff, Timothy A.; Spinhirne, James D.; Holben, Brent; Tsay, Si-Chee
2004-01-01
We present the formation of a global-ground based eye-safe lidar network, the NASA Micro-Pulse Lidar Network (MPLNET). The aim of MPLNET is to acquire long-term observations of aerosol and cloud vertical profiles at unique geographic sites within the NASA Aerosol Robotic Network (AERONET). Network growth follows a federated approach, pioneered by AERONET, wherein independent research groups may join MPLNET with their own instrument and site. MPLNET utilizes standard instrumentation and data processing algorithms for efficient network operations and direct comparison of data between each site. The micro-pulse lidar is eye-safe, compact, and commercially available, and most easily allows growth of the network without sacrificing standardized instrumentation gods. Red-time data products (next-day) are available, and include Level 1 daily lidar signal images from the surface to -2Okm, and Level 1.5 aerosol extinction provides at times co-incident with AERONET observations. Testing of our quality assured aerosol extinction products, Level 2, is near completion and data will soon be available. Level 3 products, continuous daylight aerosol extinction profiles, are under development and testing has begun. An overview of h4PL" will be presented. Successful methods of merging standardized lidar operations with AERONET will also be discussed, with the first 4 years of MPLNET results serving as an example.
Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) Instrument Improvements
NASA Technical Reports Server (NTRS)
Dunagan, Stephen E.; Redemann, Jens; Chang, Cecilia; Dahlgren, Robert; Fahey, Lauren; Flynn, Connor; Johnson, Roy; Kacenelenbogen, Meloe; Leblanc, Samuel; Liss, Jordan;
2017-01-01
The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with grating spectroscopy to improve knowledge of atmospheric constituents and their links to air-pollution and climate. Hyper-spectral measurements of direct-beam solar irradiance provide retrievals of gas constituents, aerosol optical depth, and aerosol and thin cloud optical properties. Sky radiance measurements in the principal and almucantar planes enhance retrievals of aerosol absorption, aerosol type, and size mode distribution. Zenith radiance measurements are used to retrieve cloud properties and phase, which in turn are used to quantify the radiative transfer below cloud layers. These airborne measurements tighten the closure between satellite and ground-based measurements. In contrast to the Ames Airborne Tracking Sunphotometer (AATS-14) predecessor instrument, new technologies for each subsystem have been incorporated into 4STAR. In particular, 4STAR utilizes a modular sun-trackingsky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and spectrometerdetector configurations that may be tailored for specific scientific objectives. This paper discusses technical challenges relating to compact optical collector design, radiometric dynamic range and stability, and broad spectral coverage at high resolution. Test results benchmarking the performance of the instrument against the AATS-14 standard and emerging science requirements are presented.
Fluorescence probe for cervical examination during various reproductive states
NASA Astrophysics Data System (ADS)
Glassman, Wenling S.; Liao, Qin-Ping; Shi, Shao-Qing; Goodrum, Linda; Olson, Gayle; Martin, Elizabeth; Saade, George; Garfield, Robert E.
1997-05-01
These studies represent further investigations that have been done utilizing the fluorescence from pyridinoline, one of the major crosslinks of type I and III collagen, to evaluate cervical connective tissue changes during various female reproductive periods. Based on our previous studies, a prototype instrument has been constructed. The instrument was specifically designed for the purpose of vaginal examination of cervical connective tissue by measuring light induced fluorescence directly from the surface of the external os of the cervix. The studies were carried out on nonpregnant rats, rats during gestation at different periods, rats at different times during postpartum, and rats during preterm birth after being treated with antiprogesterone drugs. A study has also been done on humans during pregnancy and postpartum. The results parallel previous investigations that have used various invasive methods to analyze cervical extensibility, cervical collagen content and collagenase. In consideration of the important role of the collagen fibers and their turnover in the process of cervical function during pregnancy (softening or ripening at term), this method could be a useful tool for evaluating treatment strategies of the cervix. Moreover, the instrument could serve as a device for the non-invasive estimation of cervical status in the clinic and the diagnosis of the changes in the cervix during the preparation for labor.
Earth observing system instrument pointing control modeling for polar orbiting platforms
NASA Technical Reports Server (NTRS)
Briggs, H. C.; Kia, T.; Mccabe, S. A.; Bell, C. E.
1987-01-01
An approach to instrument pointing control performance assessment for large multi-instrument platforms is described. First, instrument pointing requirements and reference platform control systems for the Eos Polar Platforms are reviewed. Performance modeling tools including NASTRAN models of two large platforms, a modal selection procedure utilizing a balanced realization method, and reduced order platform models with core and instrument pointing control loops added are then described. Time history simulations of instrument pointing and stability performance in response to commanded slewing of adjacent instruments demonstrates the limits of tolerable slew activity. Simplified models of rigid body responses are also developed for comparison. Instrument pointing control methods required in addition to the core platform control system to meet instrument pointing requirements are considered.
Utility analysis and calibration of QOL assessment in disease management.
Liu, Mo
2018-05-02
In clinical trials, the assessment of health-related quality of life (QOL) (or patient-reported outcome [PRO] measure) has become very popular especially for clinical studies conducted for evaluating clinical benefits of patients with chronic, severe, and/or life threatening diseases. Health-related QOL information and PRO measures are useful for disease management for achieving best clinical practice. In this article, we will focus on health-related QOL assessment. The concept, design, and analysis of health-related QOL in clinical trials are reviewed. Validation of the use of health-related QOL instrument in terms of some key performance characteristics such as accuracy, reliability, sensitivity, and responsibility for assuring quality, integrity, and validity of collected QOL data are discussed. The concept of utility analysis and calibration (e.g., with respect to life events) for achieving the optimization of disease management are proposed. The change of the QOL could be translated into different life events for effective disease management. These translations could evaluate the treatment effect by more directly displaying the change of the QOL.
Quiescent hydrogen sulfide and carbon dioxide degassing from Mount Baker, Washington
McGee, K.A.; Doukas, M.P.; Gerlach, T.M.
2001-01-01
Volcanic H2S emission rate data are scant despite their importance in understanding magma degassing. We present results from direct airborne plume measurements of H2S and CO2 on a 21-orbit survey at eleven different altitudes around Mount Baker volcano in September 2000 utilizing instrumentation mounted in a light aircraft. Measured emission rates of H2S and CO2 were 5.5 td-1 and 187 td-1 respectively. Maximum concentrations of H2S and CO2 encountered within the 4-km-wide plume were 75 ppb and 2 ppm respectively. Utilizing the H2S signal as a marker for the plume allows the corresponding CO2 signal to be more easily and accurately distinguished from ambient CO2 background. This technique is sensitive enough for monitoring weakly degassing volcanoes in a pre-eruptive condition when scrubbing by hydrothermal fluid or aquifers might mask the presence of more acid magmatic gases such as SO2.
ERIC Educational Resources Information Center
Bøllingtoft Knudsen, Søren
2018-01-01
Focus on evidence-based policymaking is greater than ever, and public spending on evaluations is rising. A primary merit of these expenditures is that politicians actually use new knowledge instrumentally--to influence and inform decision making. Nevertheless, we know surprisingly little about whether and how research-based knowledge is utilised.…
ERIC Educational Resources Information Center
Stein, Mary; Barman, Charles R.; Larrabee, Timothy
2007-01-01
This article describes the rationale for, and development of, an online instrument that helps identify commonly held science misconceptions. Science Beliefs is a 47-item instrument that targets topics in chemistry, physics, biology, earth science, and astronomy. It utilizes a true or false, along with a written-explanation, format. The true or…
ERIC Educational Resources Information Center
Hill, Andreas; Rettenberger, Martin; Habermann, Niels; Berner, Wolfgang; Eher, Reinhard; Briken, Peer
2012-01-01
To examine the predictive accuracy of four well established risk assessment instruments (PCL-R, HCR-20, SVR-20, and Static-99) in an important subgroup of sexual offenders, these instruments were assessed retrospectively based on information from forensic psychiatric court reports in a sample of 90 released male sexual homicide offenders (out of…
ERIC Educational Resources Information Center
Riches, Vivienne C.; Parmenter, Trevor R.; Llewellyn, Gwynnyth; Hindmarsh, Gabrielle; Chan, Jeff
2009-01-01
Background: There is an urgent need for developing reliable, valid and practical instruments that assess and classify the support needed by persons with disability to function in their chosen living, working and social environments. I-CAN is an instrument that addresses the frequency and level of support needed (not individual skills or deficits)…
The Community of Inquiry Instrument: Validation and Results in Online Health Care Disciplines
ERIC Educational Resources Information Center
Carlon, S.; Bennett-Woods, D.; Berg, B.; Claywell, L.; LeDuc, K.; Marcisz, N.; Mulhall, M.; Noteboom, T.; Snedden, T.; Whalen, K.; Zenoni, L.
2012-01-01
This descriptive study using survey design sought to establish the efficacy of the Community of Inquiry instrument utilized in a study published by Shea and Bidjerano in 2009 exploring an online community of business students in a multi-institutional study. The current study sought to validate the instrument with a population of students in three…
Study of labor-negotiation productivity concerns in the petroleum-refining industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, J.E.
The primary objective of this study was to identify productivity factors relative to negotiating future labor contracts with the Oil, Chemical and Atomic Workers International Union (OCAWIU). A Delphi research method was utilized to accomplish this purpose. The study utilized three rounds to obtain the stated objectives. Round one involved the use of an open instrument to solicit productivity factors that would be beneficial in future negotiations with the OCAWIU. In round two, two separate instruments were sent to the panel members who were asked to judge the value of each item on the first instrument, and to rank themore » ten most significant items on the second. The round three instruments were individualized for each panel member. The productivity items were rated by the panel members, and descriptive statistics were used to describe the combined order of listings and weights for determining the relative importance of each factor in the consensus model. The nonparametric statistics were used to examine the degree of consensus between the mean values on the first instrument with the ranked values for the second instrument. No significant differences were formed. Twenty-five productivity items were identified and prioritized as viable negotiable items with the OCAWIU.« less
Hagemeier, Nicholas E; Murawski, Matthew M
2014-02-12
To develop and validate an instrument to assess subjective ratings of the perceived value of various postgraduate training paths followed using expectancy-value as a theoretical framework; and to explore differences in value beliefs across type of postgraduate training pursued and type of pharmacy training completed prior to postgraduate training. A survey instrument was developed to sample 4 theoretical domains of subjective task value: intrinsic value, attainment value, utility value, and perceived cost. Retrospective self-report methodology was employed to examine respondents' (N=1,148) subjective task value beliefs specific to their highest level of postgraduate training completed. Exploratory and confirmatory factor analytic techniques were used to evaluate and validate value belief constructs. Intrinsic, attainment, utility, cost, and financial value constructs resulted from exploratory factor analysis. Cross-validation resulted in a 26-item instrument that demonstrated good model fit. Differences in value beliefs were noted across type of postgraduate training pursued and pharmacy training characteristics. The Postgraduate Training Value Instrument demonstrated evidence of reliability and construct validity. The survey instrument can be used to assess value beliefs regarding multiple postgraduate training options in pharmacy and potentially inform targeted recruiting of individuals to those paths best matching their own value beliefs.
NASA Astrophysics Data System (ADS)
Kraft, S.; Puschmann, K. G.; Luntama, J. P.
2017-09-01
As part of the Space Situational Awareness Programme (SSA), ESA has initiated the assessment of two missions currently foreseen to be implemented to enable enhanced space weather monitoring. These missions utilize the positioning of satellites at the Lagrangian L1 and L5 points. These Phase 0 or Pre-Phase A mission studies are about to be completed and will thereby have soon passed the Mission Definition Review. Phase A studies are planned to start in 2017. The space weather monitoring system currently considers four remote sensing optical instruments and several in-situ instruments to analyse the Sun and the solar wind conditions, in order to provide early warnings of increased solar activity and to identify and mitigate potential threats to society and ground, airborne and space based infrastructure. The suggested optical instruments take heritage from ESA and NASA science missions like SOHO, STEREO and Solar Orbiter, but the instruments are foreseen to be optimized for operational space weather monitoring purposes with high reliability and robustness demands. The instruments are required to provide high quality measurements particularly during severe space weather events. The program intends to utilize the results of the on-going ESA instrument prototyping and technology development activities, and to initiate pre-developments of the operational space weather instruments to ensure the required maturity before the mission implementation.
Cadorin, Lucia; Bressan, Valentina; Palese, Alvisa
2017-11-25
Modern healthcare institutions are continuously changing, and Self-Directed Learning (SDL) abilities are considered a prerequisite for both nursing students and nurses in order to be proactive about these demanding challenges. To date, no systematic reviews of existing instruments aimed at detecting and critically evaluating SDL abilities have been published. Therefore, the aims of this review are: 1) identify the instruments for assessment of SDL abilities among nursing students and nurses; 2) critically evaluate the methodological studies quality; and 3) compare the psychometric properties of the available instruments. A psychometric-systematic-review was performed. CDSR, CINAHL, ERIC, MEDLINE, PROSPERO, SCOPUS databases were searched without restrictions in time and setting. All primary studies involving nursing students or nurses, written in English and aimed at validating SDL assessment tools, were included. Studies retrieved were evaluated according to the COnsensus-based-Standards for the selection of health Measurement-INstruments (COSMIN) panel. Study inclusion, data extraction and quality assessment were performed by researchers independently. Eleven studies were included and four tools based on Knowles's theory have emerged: 1) the Self-Directed Learning Readiness Scale; 2) the Self-Directed Learning Readiness Scale for Nursing Education; 3) the Self-Rating Scale of Self-Directed Learning, and 4) the Self-Directed Learning Instrument. A few psychometric properties have been considered in each study, from two to four out of the ten required. The quality of the methodologies used was in general, from fair to poor with the exception of one instrument (the Self-Directed-Learning-Instrument). The psychometric proprieties that emerged across the tools were good in general: the Cronbach α was from 0.73 to 0.91; structural validities have also reported good indexes both in the explorative and in the confirmative factor analyses. On the basis of the findings, the Self-Directed-Learning-Instrument can be recommended for the assessment of SDL abilities among nursing students and nurses, given the excellent methodology quality adopted in estimating the psychometric properties. However, rigorous study designs aimed at estimating psychometric properties of tools in wide samples of nursing students and nurses across different stages of professional life, from undergraduate education to professional maturity, in different cultural, educational, and work settings, are strongly recommended.
NASA Astrophysics Data System (ADS)
Byers, C. P.; Fu, M. K.; Fan, Y.; Hultmark, M.
2018-02-01
A novel method of obtaining two orthogonal velocity components with high spatial and temporal resolution is investigated. Both components are obtained utilizing a single sensing nanoribbon by combining the two independent operating modes of classic hot wire anemometry and the newly discovered elastic filament velocimetry (EFV). In contrast to hot wire anemometry, EFV measures fluid velocity through correlating the fluid forcing with the internal strain of the wire. In order to utilize both modes of operation, a system that switches between the two operating modes is built and characterized, and the theoretically predicted sensing response time in water is compared to experimental results. The sensing system is capable of switching between the two modes of operation at a frequency of 100 kHz with minimal attenuation with an uncompensated repetition rate up to 3 kHz or up to 10 kHz utilizing modest signal compensation. While further characterization of the sensor performance in air is needed, this methodology enables a technique for obtaining well-resolved yet cost-efficient directional measurements of flow velocities which, for example, can be used for distributed measurements of velocity or measurements of turbulent stresses with excellent spatial resolution.
NASA Astrophysics Data System (ADS)
Schaffer, G.; Marks, D.
2004-12-01
Since 1978 snow deposition and SWE in the inter-mountain western US have been monitored by the NRCS SNOTEL (SNOwpack TELemetry) system. This revolutionary network utilizes Meteorburst technology to telemeter data back to a central location in near real-time. With a pilot program starting in 1991, NRCS introduced SCAN (Soil Climate and Analysis Network) adding a focus on soil moisture and climate in regions outside the intermountain west. In the mid-1990's SNOTEL sites began to be augmented to match the full climate instrumentation (air temperature, humidity, solar radiation, wind, and soil moisture and temperature in addition to precipitation, snow depth and SWE) of the SCAN system. At present there are nearly 700 SNOTEL sites in 12 states in the western US and Alaska, and over 100 SCAN sites in 40 states, Puerto Rico, and several foreign countries. Though SNOTEL was originally a western snow-monitoring network, differences between SCAN and SNOTEL have largely disappeared. The combined SNOTEL/SCAN system provides a continental-scale mesonet to support river basin to continental scale hydro-climatic analysis. The system is flexible and based on off-the-shelf data recording technology, allowing instrumentation, sampling and averaging intervals to be specified by site conditions, issues, or scientific questions. Because of the NRCS data management structure, all sites have active telemetery and provide near real-time access to data through the internet. An ongoing research program is directed to improved instrumentation for measuring precipitation, snow depth and SWE, and soil moisture and temperature. Future directions include expansion of the network to be more comprehensive, and to develop focused monitoring efforts to more effectively observe elevational and regional gradients, and to capture high intensity hydro-climatic events such as potential flooding from convective storms and rain-on-snow.
From clinically relevant outcome measures to quality of life in epilepsy: A time trade-off study.
de Kinderen, Reina J A; Wijnen, Ben F M; van Breukelen, Gerard; Postulart, Debby; Majoie, Marian H J M; Aldenkamp, Albert P; Evers, Silvia M A A
2016-09-01
A proposed method for bridging the gap between clinically relevant epilepsy outcome measures and quality-adjusted life years is to derive utility scores for epilepsy health states. The aim of this study is to develop such a utility-function and to investigate the impact of the epilepsy outcome measures on utility. Health states, based on clinically important epilepsy attributes (e.g. seizure frequency, seizure severity, side-effects), were valued by a sample of the Dutch population (N=525) based on the time trade-off method. In addition to standard demographics, every participant was asked to rate 10 or 11 different health state scenarios. A multilevel regression analysis was performed to account for the nested structure of the data. Results show that the best health state (no seizures and no side-effects) is estimated at 0.89 and the worst state (seizures type 5 twice a day plus severe side-effects) at 0.22 (scale: 0-1). An increase in seizure frequency, occurrence of side-effects, and seizure severity were all significantly associated with lower utility values. Furthermore, seizure severity has the largest impact on quality of life compared with seizure frequency and side-effects. This study provides a utility-function for transforming clinically relevant epilepsy outcome measures into utility estimates. We advise using our utility-function in economic evaluations, when quality of life is not directly measured in a study and hence, no health state utilities are available, or when there is convincing empirical evidence of the insensitivity of a generic quality-of-life-instrument within epilepsy. Copyright © 2016 Elsevier B.V. All rights reserved.
A Systematic Review of Head and Neck Cancer Quality of Life Assessment Instruments
Ojo, Bukola; Genden, Eric M.; Teng, Marita S.; Milbury, Kathrin; Misiukiewicz, Krzysztof J.; Badr, Hoda
2012-01-01
Summary Although quality of life (QOL) is an important treatment outcome in head and neck cancer (HNC), cross-study comparisons have been hampered by the heterogeneity of measures used and the fact that reviews of HNC QOL instruments have not been comprehensive to date. We performed a systematic review of the published literature on HNC QOL instruments from 1990–2010, categorized, and reviewed the properties of the instruments using international guidelines as reference. Of the 2766 articles retrieved, 710 met the inclusion criteria and used 57 different head and neck-specific instruments to assess QOL. A review of the properties of these utilized measures and identification of areas in need of further research is presented. Given the volume and heterogeneity of QOL measures, there is no gold standard questionnaire. Therefore, when selecting instruments, researchers should consider not only psychometric properties but also research objectives, study design, and the pitfalls and benefits of combining different measures. Although great strides have been made in the assessment of QOL in HNC and researchers now have a plethora of quality instruments to choose from, more work is needed to improve the clinical utility of these measures in order to link QOL research to clinical practice. This review provides a platform for head and neck-specific instrument comparisons, with suggestions of important factors to consider in the systematic selection of QOL instruments, and is a first step towards translation of QOL assessment into the clinical scene. PMID:22525604
NASA Technical Reports Server (NTRS)
Rosen, Charles D.; Mitchell, Shirley M.; Jolly, Stanley R.; Jackson, Richard G.; Fleming, Scott T.; Roberts, William J.; Bell, Daniel R., III
1996-01-01
Instrument yielding presence or absence of waterproofing agent at any given depth in blanket developed. In original application, blankets in question part of space shuttle thermal protection system. Instrument utilized to determine extent of waterproofing "burnout" due to re-entry heating and adverse environment exposure.
7 CFR 4287.124 - Alterations of loan instruments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 4287.124 Agriculture Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE SERVICING Servicing Business and... approve any alterations of any loan instrument without the prior written approval of the Agency. ...
Monitoring food pathogens: Novel instrumentation for cassette PCR testing
Hunt, Darin; Figley, Curtis; Lauzon, Jana; Figley, Rachel; Pilarski, Linda M.; McMullen, Lynn M.; Pilarski, Patrick M.
2018-01-01
In this manuscript, we report the design and development of a fast, reliable instrument to run gel-based cassette polymerase chain reactions (PCR). Here termed the GelCycler Mark II, our instrument is a miniaturized molecular testing system that is fast, low cost and sensitive. Cassette PCR utilizes capillary reaction units that carry all reagents needed for PCR, including primers and Taq polymerase, except the sample, which is loaded at the time of testing. Cassette PCR carries out real time quantitative PCR followed by melt curve analysis (MCA) to verify amplicon identity at the expected melt temperature (Tm). The cassette PCR technology is well developed, particularly for detecting pathogens, and has been rigorously validated for detecting pathogenic Escherichia coli in meat samples. However, the work has been hindered by the lack of a robust and stable instrument to carry out the PCR, which requires fast and accurate temperature regulation, improved light delivery and fluorescent recording, and faster PCR reactions that maintain a high sensitivity of detection. Here, we report design and testing of a new instrument to address these shortcomings and to enable standardized testing by cassette PCR and commercial manufacture of a robust and accurate instrument that can be mass produced to deliver consistent performance. As a corollary to our new instrument development, we also report the use of an improved design approach using a machined aluminum cassette to meet the new instrument standards, prevent any light bleed across different trenches in each cassette, and allow testing of a larger number of samples for more targets in a single run. The GelCycler Mark II can detect and report E. coli contamination in 41 minutes. Sample positives are defined in as having a melt curve comparable to the internal positive control, with peak height exceeding that of the internal negative control. In a fractional analysis, as little as 1 bacterium per capillary reaction unit is directly detectable, with no enrichment step, in 35 cycles of PCR/MCA, in a total time of 53 minutes, making this instrument and technology among the very best for speed and sensitivity in screening food for pathogenic contamination. PMID:29746561
Utilization of Space Station Freedom for technology research
NASA Technical Reports Server (NTRS)
Avery, Don E.
1992-01-01
Space Station Freedom presents a unique opportunity for technology developers to conduct research in the space environment. Research can be conducted in the pressurized volume of the Space Station's laboratories or attached to the Space Station truss in the vacuum of space. Technology developers, represented by the Office of Aeronautics and Space Technology (OAST), will have 12 percent of the available Space Station resources (volume, power, data, crew, etc.) to use for their research. Most technologies can benefit from research on Space Station Freedom and all these technologies are represented in the OAST proposed traffic model. This traffic model consists of experiments that have been proposed by technology developers but not necessarily selected for flight. Experiments to be flown in space will be selected through an Announcement of Opportunity (A.O.) process. The A.O. is expected to be released in August, 1992. Experiments will generally fall into one of the 3 following categories: (1) Individual technology experiments; (2) Instrumented Space Station; and (3) Guest investigator program. The individual technology experiments are those that do not instrument the Space Station nor directly relate to the development of technologies for evolution of Space Station or development of advanced space platforms. The Instrumented Space Station category is similar to the Orbiter Experiments Program and allows the technology developer to instrument subsystems on the Station or develop instrumentation packages that measure products or processes of the Space Station for the advancement of space platform technologies. The guest investigator program allows the user to request data from Space Station or other experiments for independent research. When developing an experiment, a developer should consider all the resources and infrastructure that Space Station Freedom can provide and take advantage of these to the maximum extent possible. Things like environment, accommodations, carriers, and integration should all be taken into account. In developing experiments at Langley Research Center, an iterative approach is proving useful. This approach uses Space Station utilization and subsystem experts to advise and critique experiment designs to take advantage of everything the Space Station has to offer. Also, solid object modeling and animation computer tools are used to fully visualize the experiment and its processes. This process is very useful for attached payloads and allows problems to be detected early in the experiment design phase.
The Soil Moisture Active and Passive (SMAP) Mission
NASA Technical Reports Server (NTRS)
Entekhabi, Dara; Nijoku, Eni G.; ONeill, Peggy E.; Kellogg, Kent H.; Crow, Wade T.; Edelstein, Wendy N.; Entin, Jared K.; Goodman, Shawn D.; Jackson, Thomas J.; Johnson, Joel;
2009-01-01
The Soil Moisture Active and Passive (SMAP) Mission is one of the first Earth observation satellites being developed by NASA in response to the National Research Council s Decadal Survey. SMAP will make global measurements of the moisture present at Earth's land surface and will distinguish frozen from thawed land surfaces. Direct observations of soil moisture and freeze/thaw state from space will allow significantly improved estimates of water, energy and carbon transfers between land and atmosphere. Soil moisture measurements are also of great importance in assessing flooding and monitoring drought. SMAP observations can help mitigate these natural hazards, resulting in potentially great economic and social benefits. SMAP soil moisture and freeze/thaw timing observations will also reduce a major uncertainty in quantifying the global carbon balance by helping to resolve an apparent missing carbon sink on land over the boreal latitudes. The SMAP mission concept would utilize an L-band radar and radiometer. These instruments will share a rotating 6-meter mesh reflector antenna to provide high-resolution and high-accuracy global maps of soil moisture and freeze/thaw state every two to three days. The SMAP instruments provide direct measurements of surface conditions. In addition, the SMAP project will use these observations with advanced modeling and data assimilation to provide deeper root-zone soil moisture and estimates of land surface-atmosphere exchanges of water, energy and carbon. SMAP is scheduled for a 2014 launch date
NASA Astrophysics Data System (ADS)
Slowik, J. G.; Brook, J.; Chang, R. Y.-W.; Evans, G. J.; Hayden, K.; Jeong, C.-H.; Li, S.-M.; Liggio, J.; Liu, P. S. K.; McGuire, M.; Mihele, C.; Sjostedt, S.; Vlasenko, A.; Abbatt, J. P. D.
2010-10-01
As part of the BAQS-Met 2007 field campaign, Aerodyne time-of-flight aerosol mass spectrometers (ToF-AMS) were deployed at two sites in southwestern Ontario from 17 June to 11 July, 2007. One instrument was located at Harrow, ON, a rural, agriculture-dominated area approximately 40 km southeast of the Detroit/Windsor/Windsor urban area and 5 km north of Lake Erie. The second instrument was located at Bear Creek, ON, a rural site approximately 70 km northeast of the Harrow site and 50 km east of Detroit/Windsor. Positive matrix factorization analysis of the combined organic mass spectral dataset yields factors related to secondary organic aerosol (SOA), direct emissions, and uptake processes. This is the first application of PMF to simultaneous AMS measurements at different sites, an approach which allows for self-consistent, direct comparison of the datasets. Case studies are utilized to investigate processing of SOA from (1) fresh emissions from Detroit/Windsor and (2) regional aerosol during periods of inter-site flow. A strong correlation is observed between SOA/excess CO and photochemical age as represented by the NOx/NOy ratio for Detroit/Windsor outflow. Although this correlation is not evident for more aged air, measurements at the two sites during inter-site transport nevertheless show evidence of continued atmospheric processing by SOA production.
ERIC Educational Resources Information Center
Wilkes, Sam T.; Blackbourn, Joe M.
This project attempts to refine the Zones of Indifference Instrument, (included in appendix) that measures zones of indifference of teachers to typical directives issued by administrators. As a result of the original validation study, a 78-item, two-factor instrument was developed. These two factors explained 52 percent of the variance. The…
Stress-induced reliance on habitual behavior is moderated by cortisol reactivity.
Smeets, T; van Ruitenbeek, P; Hartogsveld, B; Quaedflieg, Conny W E M
2018-05-25
Instrumental learning, i.e., learning that specific behaviors lead to desired outcomes, occurs through goal-directed and habit memory systems. Exposure to acute stress has been shown to result in less goal-directed control, thus rendering behavior more habitual. The aim of the current studies was to replicate and extend findings on stress-induced prompting of habitual responding and specifically focused on the role of stress-induced cortisol reactivity. Study 1 used an established outcome devaluation paradigm to assess goal-directed and habitual control. Study 2 utilized a modified version of this paradigm that was intended to establish stronger habitual responding through more extensive reward training and applying a relevant behavioral devaluation procedure (i.e., eating to satiety). Both studies failed to replicate that stress overall, i.e., independent of cortisol reactivity, shifted behavior from goal-directed to habitual control. However, both studies found that relative to stress-exposed cortisol non-responders and no-stress controls, participants displaying stress-induced cortisol reactivity displayed prominent habitual responding. These findings highlight the importance of stress-induced cortisol reactivity in facilitating habits. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Quantitative Profiling of DNA Damage and Apoptotic Pathways in UV Damaged Cells Using PTMScan Direct
Stokes, Matthew P.; Silva, Jeffrey C.; Jia, Xiaoying; Lee, Kimberly A.; Polakiewicz, Roberto D.; Comb, Michael J.
2013-01-01
Traditional methods for analysis of peptides using liquid chromatography and tandem mass spectrometry (LC-MS/MS) lack the specificity to comprehensively monitor specific biological processes due to the inherent duty cycle limitations of the MS instrument and the stochastic nature of the analytical platform. PTMScan Direct is a novel, antibody-based method that allows quantitative LC-MS/MS profiling of specific peptides from proteins that reside in the same signaling pathway. New PTMScan Direct reagents have been produced that target peptides from proteins involved in DNA Damage/Cell Cycle and Apoptosis/Autophagy pathways. Together, the reagents provide access to 438 sites on 237 proteins in these signaling cascades. These reagents have been used to profile the response to UV damage of DNA in human cell lines. UV damage was shown to activate canonical DNA damage response pathways through ATM/ATR-dependent signaling, stress response pathways and induce the initiation of apoptosis, as assessed by an increase in the abundance of peptides corresponding to cleaved, activated caspases. These data demonstrate the utility of PTMScan Direct as a multiplexed assay for profiling specific cellular responses to various stimuli, such as UV damage of DNA. PMID:23344034
Utilization of the High Flux Isotope Reactor at Oak Ridge National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selby, Douglas L; Bilheux, Hassina Z; Meilleur, Flora
2015-01-01
This paper addresses several aspects of the scientific utilization of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Topics to be covered will include: 1) HFIR neutron scattering instruments and the formal instrument user program; 2) Recent upgrades to the neutron scattering instrument stations at the reactor, and 3) eMod a new tool for addressing instrument modifications and providing configuration control and design process for scientific instruments at HFIR and the Spallation Neutron Source (SNS). There are 15 operating neutron instrument stations at HFIR with 12 of them organized into a formal user program. Since the last presentationmore » on HFIR instruments at IGORR we have installed a Single Crystal Quasi-Laue Diffractometer instrument called IMAGINE; and we have made significant upgrades to HFIR neutron scattering instruments including the Cold Triple Axis Instrument, the Wide Angle Neutron Diffractometer, the Powder Diffractometer, and the Neutron Imaging station. In addition, we have initiated upgrades to the Thermal Triple Axis Instrument and the Bio-SANS cold neutron instrument detector system. All of these upgrades are tied to a continuous effort to maintain a high level neutron scattering user program at the HFIR. For the purpose of tracking modifications such as those mentioned and configuration control we have been developing an electronic system for entering instrument modification requests that follows a modification or instrument project through concept development, design, fabrication, installation, and commissioning. This system, which we call eMod, electronically leads the task leader through a series of questions and checklists that then identifies such things as ES&H and radiological issues and then automatically designates specific individuals for the activity review process. The system has been in use for less than a year and we are still working out some of the inefficiencies, but we believe that this will become a very effective tool for achieving the configuration and process control believed to be necessary for scientific instrument systems.« less
Performance of PROMIS Instruments in Patients With Shoulder Instability.
Anthony, Chris A; Glass, Natalie A; Hancock, Kyle; Bollier, Matt; Wolf, Brian R; Hettrich, Carolyn M
2017-02-01
Shoulder instability is a relatively common condition occurring in 2% of the population. PROMIS (Patient-Reported Outcome Measurement Information System) was developed by the National Institutes of Health in an effort to advance patient-reported outcome (PRO) instruments by developing question banks for major health domains. To compare PROMIS instruments to current PRO instruments in patients who would be undergoing operative intervention for recurrent shoulder instability. Cohort study (diagnosis); Level of evidence, 2. A total of 74 patients with a primary diagnosis of shoulder instability who would be undergoing surgery were asked to fill out the American Shoulder and Elbow Surgeons shoulder assessment form (ASES), Marx shoulder activity scale (Marx), Short Form-36 Health Survey Physical Function subscale (SF-36 PF), Western Ontario Shoulder Instability Index (WOSI), PROMIS physical function computer adaptive test (PF CAT), and PROMIS upper extremity item bank (UE). Correlation between PRO instruments was defined as excellent (>0.7), excellent-good (0.61-0.7), good (0.4-0.6), and poor (0.2-0.3). Utilization of the PROMIS UE demonstrated excellent correlation with the SF-36 PF ( r = 0.78, P < .01) and ASES ( r = 0.71, P < .01); there was excellent-good correlation with the EQ-5D ( r = 0.66, P < .01), WOSI ( r = 0.63, P < .01), and PROMIS PF CAT ( r = 0.63, P < .01). Utilization of the PROMIS PF CAT demonstrated excellent correlation with the SF-36 PF ( r = 0.72, P < .01); there was excellent-good correlation with the ASES ( r = 0.67, P < .01) and PROMIS UE ( r = 0.63, P < .01). When utilizing the PROMIS UE, ceiling effects were present in 28.6% of patients aged 18 to 21 years. Patients, on average, answered 4.6 ± 1.8 questions utilizing the PROMIS PF CAT. The PROMIS UE and PROMIS PF CAT demonstrated good to excellent correlation with common shoulder and upper extremity PRO instruments as well as the SF-36 PF in patients with shoulder instability. In patients aged ≤21 years, there were significant ceiling effects utilizing the PROMIS UE. While the PROMIS PF CAT appears appropriate for use in adults of any age, our findings demonstrate that the PROMIS UE has significant ceiling effects in patients with shoulder instability who are ≤21 years old, and we do not recommend use of the PROMIS UE in this population.
Weather Prediction Improvement Using Advanced Satellite Technology
NASA Technical Reports Server (NTRS)
Einaudi, Franco; Uccellini, L.; Purdom, J.; Rogers, D.; Gelaro, R.; Dodge, J.; Atlas, R.; Lord, S.
2001-01-01
We discuss in this paper some of the problems that exist today in the fall utilization of satellite data to improve weather forecasts and we propose specific recommendations to solve them. This discussion can be viewed as an aspect of the general debate on how best to organize the transition from research to operational satellites and how to evaluate the impact of a research instrument on numerical weather predictions. A method for providing this transition is offered by the National Polar-Orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP). This mission will bridge the time between the present NOAA and Department of Defense (DOD) polar orbiting missions and the initiation of the converged NPOESS series and will evaluate some of the Earth Observing System (EOS) instruments as appropriate for operational missions. Thus, this mission can be viewed as an effort to meet the operational requirements of NOAA and DOD and the research requirements of NASA. More generally, however, it can be said that the process of going from the conception of new, more advanced instruments to their operational implementation and full utilization by the weather forecast communities is not optimal. Instruments developed for research purposes may have insufficient funding to explore their potential operational capabilities. Furthermore, instrument development programs designed for operational satellites typically have insufficient funding for assimilation algorithms needed to transform the satellite observations into data that can be used by sophisticated global weather forecast models. As a result, years often go by before satellite data are efficiently used for operational forecasts. NASA and NOAA each have unique expertise in the design of satellite instruments, their use for basic and applied research and their utilization in weather and climate research. At a time of limited resources, the two agencies must combine their efforts to work toward common goals of full utilization of satellite data. This is a challenge that requires the assimilation of myriad new data into increasingly sophisticated numerical forecast models that run on increasingly sophisticated computer systems. In section II, we briefly outline the impact of satellite data on the quality of the National Centers for Environmental Prediction (NCEP) forecasts. In section III, we describe the present status of the utilization of satellite data in NCEP models and the challenges that lie ahead. In section IV, we propose solutions whose goals are summarized in section V.
Seismic instrumentation of buildings
Çelebi, Mehmet
2000-01-01
The purpose of this report is to provide information on how and why we deploy seismic instruments in and around building structures. The recorded response data from buildings and other instrumented structures can be and are being primarily used to facilitate necessary studies to improve building codes and therefore reduce losses of life and property during damaging earthquakes. Other uses of such data can be in emergency response situations in large urban environments. The report discusses typical instrumentation schemes, existing instrumentation programs, the steps generally followed in instrumenting a structure, selection and type of instruments, installation and maintenance requirements and data retrieval and processing issues. In addition, a summary section on how recorded response data have been utilized is included. The benefits from instrumentation of structural systems are discussed.
Astronomical Instrumentation System Markup Language
NASA Astrophysics Data System (ADS)
Goldbaum, Jesse M.
2016-05-01
The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.
Optimal A-Train Data Utilization: A Use Case of Aura OMI L2G and MERRA-2 Aerosol Products
NASA Technical Reports Server (NTRS)
Zeng, Jian; Shen, Suhung; Wei, Jennifer; Meyer, David J.
2017-01-01
Ozone Monitoring Instrument (OMI) aboard NASA's Aura mission measures ozone column and profile, aerosols, clouds, surface UV irradiance, and the trace gases including NO2, SO2, HCHO, BrO, and OClO using UltraViolet electromagnetic spectrum (280 - 400 nm) with a daily global coverage and a pixel spatial resolution of 13 km × 24 km at nadir, and it's been one of the key instruments to study the Earth's atmospheric composition and chemistry. The second Modern-Era Retrospective analysis for Research and Applications (MERRA-2) is NASA's atmospheric reanalysis using an upgraded version of Goddard Earth Observing System Model, version 5 (GEOS-5) data assimilation system. Compared to its predecessor MERRA, MERRA-2 is enhanced with more aspects of the Earth system among which is aerosol assimilation. When comparing between satellite pixel measurements and modeled grid data, how to properly handle counterpart pairing is critical considering their spatial and temporal variations. The comparison between satellite and model data by simply using Level 3 (L3) products may result biases due to lack of detailed temporal information. It has been preferred to inter-compare or implement satellite derived physical quantity (i.e., Level 2 (L2) Swath type) directly with/to model measurements with higher temporal and spatial resolution as possible. However, this has posed a challenge in the community to handle. Rather than directly handling the L2 or L3 data, there is a Level 2G (L2G) product conserving L2 pixel scientific data quality but in Grid type with the global coverage. In this presentation, we would like to demonstrate the optimal utilization of OMI L2G daily aerosol products by comparing with MERRA-2 hourly aerosol simulations matched well in both space and time.
GeoCARB design maturity and geostationary heritage
NASA Astrophysics Data System (ADS)
Sawyer, Kevin; Clark, Charles; Katz, Noah; Kumar, Jack; Nast, Ted; Palmer, Alice
2013-09-01
Our companion paper `Progress in development of Tropospheric Infrared Mapping Spectrometers (TIMS): geostationary greenhouse gas (GHG) application' describes geoCARB performance and science. Here we describe a geoCARB instrument design study leading to near PDR maturity. It is based on heritage geostationary (AIA and HMI on SDO, SBIRS GEO-1 and upcoming GLM on GOES-R as examples) and other (IRIS and NIRcam) flight instrumentation. Heritage work includes experience and well developed specifications for near a-thermal carbon fiber honeycomb composite optical benches and optical element mounting design forms that utilize a "family" of mounts for nearly any type of optical element. The geoCARB approach utilizes composite optical benches and bipod flexures to kinematically mount optics. Tooling for alignment and staking of all elements is integral to the design and is "removed before flight" for mass minimization. GeoCARB requires a cryogenic region for focal planes and spectrometers but front end optics and main structure are designed to run much warmer. A star tracker is used for geoCARB posteriori geolocation including pseudo-diurnal thermal distortion characterization. It is kinematically mounted by low conductance thermal isolators directly on to the low expansion high stiffness composite bench that defines the master optical surfaces including the scanning mirrors. The thermal load from the camera heads is routed away from the bench heat pipes. Use of kinematic mounting is advantageous for low thermal conduction designs. Honeycomb composites enable the design's low thermal mechanical distortions.
Development of lidar sensor for cloud-based measurements during convective conditions
NASA Astrophysics Data System (ADS)
Vishnu, R.; Bhavani Kumar, Y.; Rao, T. Narayana; Nair, Anish Kumar M.; Jayaraman, A.
2016-05-01
Atmospheric convection is a natural phenomena associated with heat transport. Convection is strong during daylight periods and rigorous in summer months. Severe ground heating associated with strong winds experienced during these periods. Tropics are considered as the source regions for strong convection. Formation of thunder storm clouds is common during this period. Location of cloud base and its associated dynamics is important to understand the influence of convection on the atmosphere. Lidars are sensitive to Mie scattering and are the suitable instruments for locating clouds in the atmosphere than instruments utilizing the radio frequency spectrum. Thunder storm clouds are composed of hydrometers and strongly scatter the laser light. Recently, a lidar technique was developed at National Atmospheric Research Laboratory (NARL), a Department of Space (DOS) unit, located at Gadanki near Tirupati. The lidar technique employs slant path operation and provides high resolution measurements on cloud base location in real-time. The laser based remote sensing technique allows measurement of atmosphere for every second at 7.5 m range resolution. The high resolution data permits assessment of updrafts at the cloud base. The lidar also provides real-time convective boundary layer height using aerosols as the tracers of atmospheric dynamics. The developed lidar sensor is planned for up-gradation with scanning facility to understand the cloud dynamics in the spatial direction. In this presentation, we present the lidar sensor technology and utilization of its technology for high resolution cloud base measurements during convective conditions over lidar site, Gadanki.
Macias, Michael S; Guerra-Diaz, Patricia; Almirall, José R; Furton, Kenneth G
2010-02-25
Currently, in the field of odor detection, there is generally a wider variation in limit of detections (LODs) for canines than instruments. The study presented in this paper introduces an improved protocol for the creation of controlled odor mimic permeation system (COMPS) devices for use as standards in canine training and discusses the canine detection thresholds of piperonal, a starting material for the illicit drug 3,4-methylenedioxymethamphetamine (MDMA), when exposed to these devices. Additionally, this paper describes the first-ever reported direct comparison of solid phase microextraction-ion mobility spectrometry (SPME-IMS) to canine detection for the MDMA odorant, piperonal. The research presented shows the reliability of COMPS devices as low cost field calibrants providing a wide range of odorant concentrations for biological and instrumental detectors. The canine LOD of piperonal emanating from the 100 ng s(-1) COMPS was found to be 1 ng as compared to the SPME-IMS LOD of piperonal in a static, closed system at 2 ng, with a linear dynamic range from 2 ng to 11 ng. The utilization of the COMPS devices would allow for training that will reduce the detection variability between canines and maintain improved consistency for training purposes. Since both SPME and IMS are field portable technologies, it is expected that this coupled method will be useful as a complement to canine detection for the field detection of MDMA. 2009 Elsevier Ireland Ltd. All rights reserved.
Direct force-measuring transducer used in blood pressure research
NASA Technical Reports Server (NTRS)
Eige, J. J.; Newgard, P. M.; Pressman, G. L.
1965-01-01
Direct force measuring transducer acts as an arterial tonometer, gives a direct readout to instrumentation, and is unaffected by ambient noise. It uses a semiconductor strain gage which is deflected by pressure pulses in the artery. The deflection changes the resistance of the gage and alters the voltage reading on the associated instrumentation.
Determining the neural substrates of goal-directed learning in the human brain.
Valentin, Vivian V; Dickinson, Anthony; O'Doherty, John P
2007-04-11
Instrumental conditioning is considered to involve at least two distinct learning systems: a goal-directed system that learns associations between responses and the incentive value of outcomes, and a habit system that learns associations between stimuli and responses without any link to the outcome that that response engendered. Lesion studies in rodents suggest that these two distinct components of instrumental conditioning may be mediated by anatomically distinct neural systems. The aim of the present study was to determine the neural substrates of the goal-directed component of instrumental learning in humans. Nineteen human subjects were scanned with functional magnetic resonance imaging while they learned to choose instrumental actions that were associated with the subsequent delivery of different food rewards (tomato juice, chocolate milk, and orange juice). After training, one of these foods was devalued by feeding the subject to satiety on that food. The subjects were then scanned again, while being re-exposed to the instrumental choice procedure (in extinction). We hypothesized that regions of the brain involved in goal-directed learning would show changes in their activity as a function of outcome devaluation. Our results indicate that neural activity in one brain region in particular, the orbitofrontal cortex, showed a strong modulation in its activity during selection of a devalued compared with a nondevalued action. These results suggest an important contribution of orbitofrontal cortex in guiding goal-directed instrumental choices in humans.
18 CFR 141.1 - FERC Form No. 1, Annual report of Major electric utilities, licensees and others.
Code of Federal Regulations, 2014 CFR
2014-04-01
... instrumentality engaged in generation, transmission, distribution, or sale of electric energy, however produced... the business of developing, transmitting, utilizing, or distributing power). (2) When to file and what...
18 CFR 141.1 - FERC Form No. 1, Annual report of Major electric utilities, licensees and others.
Code of Federal Regulations, 2012 CFR
2012-04-01
... instrumentality engaged in generation, transmission, distribution, or sale of electric energy, however produced... the business of developing, transmitting, utilizing, or distributing power). (2) When to file and what...
18 CFR 141.1 - FERC Form No. 1, Annual report of Major electric utilities, licensees and others.
Code of Federal Regulations, 2013 CFR
2013-04-01
... instrumentality engaged in generation, transmission, distribution, or sale of electric energy, however produced... the business of developing, transmitting, utilizing, or distributing power). (2) When to file and what...
18 CFR 141.1 - FERC Form No. 1, Annual report of Major electric utilities, licensees and others.
Code of Federal Regulations, 2011 CFR
2011-04-01
... instrumentality engaged in generation, transmission, distribution, or sale of electric energy, however produced... the business of developing, transmitting, utilizing, or distributing power). (2) When to file and what...
Neutron probes for the Construction and Resource Utilization eXplorer (CRUX)
NASA Technical Reports Server (NTRS)
Elphic, R. C.; Hahn, S.; Lawrence, D. J.; Feldman, W. C.; Johnson, J. B.; Haldemann, A. F. C.
2006-01-01
The Construction and Resource Utilization eXplorer (CRUX) project is developing a flexible integrated suite of instruments with data fusion software and an executive controller for in situ regolith resource assessment and characterization.
Compendium of Instrumentation Whitepapers on Frontier Physics Needs for Snowmass 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lipton, R.
2013-01-01
Contents of collection of whitepapers include: Operation of Collider Experiments at High Luminosity; Level 1 Track Triggers at HL-LHC; Tracking and Vertex Detectors for a Muon Collider; Triggers for hadron colliders at the energy frontier; ATLAS Upgrade Instrumentation; Instrumentation for the Energy Frontier; Particle Flow Calorimetry for CMS; Noble Liquid Calorimeters; Hadronic dual-readout calorimetry for high energy colliders; Another Detector for the International Linear Collider; e+e- Linear Colliders Detector Requirements and Limitations; Electromagnetic Calorimetry in Project X Experiments The Project X Physics Study; Intensity Frontier Instrumentation; Project X Physics Study Calorimetry Report; Project X Physics Study Tracking Report; The LHCbmore » Upgrade; Neutrino Detectors Working Group Summary; Advanced Water Cherenkov R&D for WATCHMAN; Liquid Argon Time Projection Chamber (LArTPC); Liquid Scintillator Instrumentation for Physics Frontiers; A readout architecture for 100,000 pixel Microwave Kinetic In- ductance Detector array; Instrumentation for New Measurements of the Cosmic Microwave Background polarization; Future Atmospheric and Water Cherenkov ?-ray Detectors; Dark Energy; Can Columnar Recombination Provide Directional Sensitivity in WIMP Search?; Instrumentation Needs for Detection of Ultra-high Energy Neu- trinos; Low Background Materials for Direct Detection of Dark Matter; Physics Motivation for WIMP Dark Matter Directional Detection; Solid Xenon R&D at Fermilab; Ultra High Energy Neutrinos; Instrumentation Frontier: Direct Detection of WIMPs; nEXO detector R&D; Large Arrays of Air Cherenkov Detectors; and Applications of Laser Interferometry in Fundamental Physics Experiments.« less
Goeree, Ron; Hopkins, Rob; Marshall, John K; Armstrong, David; Ungar, Wendy J; Goldsmith, Charles; Allen, Christopher; Anvari, Mehran
2011-01-01
Very few randomized controlled trials (RCTs) have compared laparoscopic Nissen fundoplication (LNF) to proton pump inhibitors (PPI) medical management for patients with chronic gastroesophageal reflux disease (GERD). Larger RCTs have been relatively short in duration, and have reported mixed results regarding symptom control and effect on quality of life (QOL). Economic evaluations have reported conflicting results. To determine the incremental cost-utility of LNF versus PPI for treating patients with chronic and controlled GERD over 3 years from the societal perspective. Economic evaluation was conducted alongside a RCT that enrolled 104 patients from October 2000 to September 2004. Primary study outcome was GERD symptoms (secondary outcomes included QOL and cost-utility). Resource utilization and QOL data collected at regular follow-up intervals determined incremental cost/QALY gained. Stochastic uncertainty was assessed using bootstrapping and methodologic assumptions were assessed using sensitivity analysis. No statistically significant differences in GERD symptom scores, but LNF did result in fewer heartburn days and improved QOL. Costs were higher for LNF patients by $3205/patient over 3 years but QOL was also higher as measured by either QOL instrument. Based on total costs, incremental cost-utility of LNF was $29,404/QALY gained using the Health Utility Index 3. Cost-utility results were sensitive to the utility instrument used ($29,404/QALY for Health Utility Index 3, $31,117/QALY for the Short Form 6D, and $76,310/QALY for EuroQol 5D) and if current lower prices for PPIs were used in the analysis. Results varied depending on resource use/costs included in the analysis, the QOL instrument used, and the cost of PPIs; however, LNF was generally found to be a cost-effective treatment for patients with symptomatic controlled GERD requiring long-term management. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Ehlers, Justis P.; Srivastava, Sunil K.; Feiler, Daniel; Noonan, Amanda I.; Rollins, Andrew M.; Tao, Yuankai K.
2014-01-01
Purpose To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. Methods We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. Results High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Conclusions Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated. PMID:25141340
In defence of utility: the medical humanities and medical education.
Blease, Charlotte
2016-06-01
The idea that a study of the humanities helps to humanise doctors has become a leitmotif within the field. It is argued that the humanities (especially, literature) help to foster insights beyond those provided by biomedical training. Healthy young medics, it is claimed, can thereby gain significant insights into patienthood, and obtain important skills that may be valuable for their professional life. But the instrumentality of the humanities is not the only justification proffered for its inclusion in medical curricula. In this paper I critically examine the two overarching justifications recurrently cited in the mainstream literature-namely, (1) the instrumental worth and (2) the intrinsic value of the medical humanities in educating doctors. Examining these theses (and focusing on the views of a leading medical humanities scholar) I show that the bifurcation into instrumental versus non-instrumental justifications is not supported by the argumentation. Instead, I find that the particulars of the supposedly intrinsic justifications amount to an unambiguously instrumental defence of the humanities. Contextualizing the present investigation to probe further, I describe a long history of debate about the role of the humanities in British education and find that it rests on unsupported dichotomies (utility vs non-utility, theoretical vs applied, educated vs trained). I conclude that the medical humanities' manifesto would be more intellectually honest and coherent, and provide a more robust defence of its value in medical education, if it chose to embrace a wholly instrumental rationale for its role. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Brenneman, Susan K; Shen, Wei; Brekke, Lee; Paczkowski, Rosirene; Bancroft, Tim; Kaplan, Sherrie H; Greenfield, Sheldon; Berger, Marc; Buesching, Don P
2014-09-01
To assess the ability of ENterprising SElective Multi-instrument BLend for hEterogeneity analysis (ENSEMBLE) Minimum Dataset instrument dimensions to discriminate among subgroups of patients expected to have differential outcomes. Patients with Type 2 diabetes, knee osteoarthritis, ischemic heart disease or heart failure completed a survey designed to represent three dimensions (health, personality and behavior). Health-related outcomes and utilization were investigated using claims data. Discriminant validity and associations between the dimensions and outcomes were assessed. A total of 2625 patients completed the survey. The dimensions discriminated 50-100% of the outcome levels across disease cohorts; behavior dimension scores did not differ significantly among the healthcare utilization level subgroups in any disease cohort. ENSEMBLE Minimum Dataset dimensions discriminated health-related outcome levels among patients with varied diseases.
NASA Technical Reports Server (NTRS)
1997-01-01
Patterned after the Cassini Resource Exchange (CRE), Sholtz and Associates established the Automated Credit Exchange (ACE), an Internet-based concept that automates the auctioning of "pollution credits" in Southern California. An early challenge of the Jet Propulsion Laboratory's Cassini mission was allocating the spacecraft's resources. To support the decision-making process, the CRE was developed. The system removes the need for the science instrument manager to know the individual instruments' requirements for the spacecraft resources. Instead, by utilizing principles of exchange, the CRE induces the instrument teams to reveal their requirements. In doing so, they arrive at an efficient allocation of spacecraft resources by trading among themselves. A Southern California RECLAIM air pollution credit trading market has been set up using same bartering methods utilized in the Cassini mission in order to help companies keep pollution and costs down.
Development of low cost and accurate homemade sensor system based on Surface Plasmon Resonance (SPR)
NASA Astrophysics Data System (ADS)
Laksono, F. D.; Supardianningsih; Arifin, M.; Abraha, K.
2018-04-01
In this paper, we developed homemade and computerized sensor system based on Surface Plasmon Resonance (SPR). The developed systems consist of mechanical system instrument, laser power sensor, and user interface. The mechanical system development that uses anti-backlash gear design was successfully able to enhance the angular resolution angle of incidence laser up to 0.01°. In this system, the laser detector acquisition system and stepper motor controller utilizing Arduino Uno which is easy to program, flexible, and low cost, was used. Furthermore, we employed LabView’s user interface as the virtual instrument for facilitating the sample measurement and for transforming the data recording directly into the digital form. The test results using gold-deposited half-cylinder prism showed the Total Internal Reflection (TIR) angle of 41,34°± 0,01° and SPR angle of 44,20°± 0,01°, respectively. The result demonstrated that the developed system managed to reduce the measurement duration and data recording errors caused by human error. Also, the test results also concluded that the system’s measurement is repeatable and accurate.
Natural orifice transluminal endoscopic surgery in urology: Review of the world literature.
Bazzi, Wassim M; Raheem, Omer A; Cohen, Seth A; Derweesh, Ithaar H
2012-01-01
Natural orifice transluminal endoscopic surgery (NOTES) has gained momentum in the recent urologic literature as a new surgical approach for intra-abdominal organs with scarless and painless postoperative recoveries. We sought to review the published literature concerning the safety and reproducibility of NOTES in urology. PubMed literature review of articles published in the English language was performed over a 10-year period, i.e., between 2001 and 2011; all articles were critically reviewed and analyzed. Despite its novelty, pure or hybrid surgical approaches have been adapted in performing NOTES. NOTES essentially utilizes transluminal flexible endoscopic instruments along with laparoscopic instruments to gain access to abdominal, pelvic, and/or retroperitoneal cavities. The preliminary results of NOTES in surgery and to a limited extent in urology appear promising, yet further research in animal survival and human cadaveric models is requisite prior to human applications, especially for complex surgeries. Future innovative research, particularly biomedical engineering, should be directed to improving the technicality and mechanistic application of NOTES; hence, better safety and efficacy of NOTES.
High-resolution mass spectrometric analysis of biomass pyrolysis vapors
Christensen, Earl; Evans, Robert J.; Carpenter, Daniel
2017-01-19
Vapors generated from the pyrolysis of lignocellulosic biomass are made up of a complex mixture of oxygenated compounds. Direct analysis of these vapors provides insight into the mechanisms of depolymerization of cellulose, hemicellulose, and lignin as well as insight into reactions that may occur during condensation of pyrolysis vapors into bio-oil. Studies utilizing pyrolysis molecular beam mass spectrometry have provided valuable information regarding the chemical composition of pyrolysis vapors. Mass spectrometers generally employed with these instruments have low mass resolution of approximately a mass unit. The presence of chemical species with identical unit mass but differing elemental formulas cannot bemore » resolved with these instruments and are therefore detected as a single ion. In this study we analyzed the pyrolysis vapors of several biomass sources using a high-resolution double focusing mass spectrometer. High-resolution analysis of pyrolysis vapors allowed for speciation of several compounds that would be detected as a single ion with unit mass resolution. Lastly, these data not only provide greater detail into the composition of pyrolysis vapors but also highlight differences between vapors generated from multiple biomass feedstocks.« less
NASA Astrophysics Data System (ADS)
Bacon, Alice Louise
This thesis represents a new interdisciplinary approach to the conservation, care and curatorial study of 'brass' wind musical instruments. It attempts to combine metallurgical, chronological and historical aspects for a selection of instruments. The research consists of the systematic study of seventy-seven musical instruments, by known makers, using standardised non-destructive energy dispersive x-ray fluorescence (XRF). Such compositional data are virtually non-existent for historical 'brass' instruments in Britain and what few technical data that do exist are sporadic in quantity and quality. The development of brass instruments is interwoven with the history of brass making, but because there are a limited number of appropriate examples such links can be difficult to identify. This thesis describes the development of brass production from the cementation process to the commercial production of zinc and modern brass. Its relationship to the musical instrument industry in Britain is linked with historical evidence. It will be shown that innovation and known historical metallurgical achievements are reflected in the compositional changes of the alloys used for musical instruments. This thesis focuses on specific named brass wind musical instrument makers. This thesis sets out to investigate the extent to which a single analytical technique such as non-destructive analysis utilising XRF could be useful in the curatorial and conservation care of musical instruments. The results of the analyses revealed new aspects to the use of metals for making musical instruments. They give new information on approximate alloy compositions and, in particular, the results have shown that in the seventeenth-century in England, a ternary alloy of copper/tin/zinc was used, and that it was, perhaps, only superseded by brass (copper/zinc alloy) in the eighteenth century. It has been possible to arrange the results into a chronology of alloys particularly reflecting the change from the use of cementation brass to the direct method for making brass. By this means it is possible to postulate a date for the composition of a musical instrument of unknown maker and date. The idea for this thesis originated in the Horniman Museum, London, where the author of this thesis is Head of Collections Conservation and Care. However this study is augmented by instruments from other institutions. In this manner it has been possible to construct a chronology from the earliest inscribed and dated instrument by Augustine Dudley in 1651 to the demise of Charles Pace's small craftsman workshop in 1854 and his death in 1867.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, Matthew B; Niedziela, Jennifer L; Abernathy, Douglas L
The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments is not exclusive and overlaps significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems.more » We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M. B.; Abernathy, D. L.; Ehlers, G.
The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. Wemore » have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.« less
Comparisons of cotton maturity and fineness measurements (Cottonscope, AFIS, HVI™)
USDA-ARS?s Scientific Manuscript database
The Cottonscope, a new instrument for fiber maturity (MR) and fineness, utilizes polarized light microscopy and image analysis to measure longitudinal, weighted fiber snippets in water. Interest has been expressed by the Commercial Standardization of Instrument Testing of Cotton (CSITC) on the pote...
Measurement of Environmental Constructs in Disability Assessment Instruments
ERIC Educational Resources Information Center
Guscia, Roma; Ekberg, Stuart; Harries, Julia; Kirby, Neil
2006-01-01
The International Classification of Functioning, Disability and Health (ICF) assumes a biopsychosocial basis for disability and provides a framework for understanding how environmental factors contribute to the experience of disability. To determine the utility of prevalent disability assessment instruments, the authors examined the extent to…
Code of Federal Regulations, 2011 CFR
2011-01-01
... (CONTINUED) ACCOUNTING REQUIREMENTS FOR RUS TELECOMMUNICATIONS BORROWERS Accounting Interpretations § 1770.26 General. (a) The standard provisions of the security instruments utilized by the Rural Utilities Service (RUS) and the Rural Telephone Bank (RTB) for all telecommunications borrowers require borrowers to at...
Schmidt, Stefanie; Garin, Olatz; Pardo, Yolanda; Valderas, José M; Alonso, Jordi; Rebollo, Pablo; Rajmil, Luis; Garcia-Forero, Carlos; Ferrer, Montse
2014-10-01
The objective was to obtain a standardized evaluation of available prostate cancer-specific quality of life instruments used in patients with early-stage disease. We carried out systematic literature reviews in the PubMed database to identify manuscripts which contained information regarding either the development process or metric properties of prostate cancer-specific quality of life instruments. Each instrument was evaluated by two experts, independently, using the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): measurement model, reliability, validity, responsiveness, interpretability, burden and alternative forms. Eight instruments and 57 manuscripts (2-15 per instrument) were identified. The Expanded Prostate Cancer Index Composite (EPIC) was the best rated (overall EMPRO score 83.1 points). Good results were also obtained by University of California Los Angeles-Prostate Cancer Index (UCLA-PCI), Patient-Oriented Prostate Utility Scale (PORPUS) and Prostate Cancer Quality of Life Instrument (PC-QoL) with 77.3, 70.5 and 64.8 points, respectively. These four instruments passed with distinction the validity and responsiveness evaluation. Insufficient reliability results were observed for UCLA-PCI and PORPUS. Current evidence supports the choice of EPIC, PORPUS or PC-QoL. Attribute-specific EMPRO results facilitate selecting the adequate instrument for every purpose. For longitudinal studies or clinical trials, where responsiveness is the priority, EPIC or PC-QoL should be considered. We recommend the PORPUS for economic evaluations because it allows cost-utility analysis, and EPIC short versions to minimize administration burden.
NASA Astrophysics Data System (ADS)
Gibbons, Beatrice Lowney
2002-01-01
The purpose of this study was to develop an evaluation instrument to be used by elementary school administrators in the promotion of constructivist teaching of elementary science for English Learners using a qualitative and quantitative design that identified effective instructional strategies to be included on the evaluation instrument. This study was conducted in fifth grade classrooms of predominately English Learners whose teachers are CLAD-certified, tenured teachers with at least three years of teaching experience. The classroom observations took place within a multicultural school district with predominantly Hispanic and Filipino students in the Southern San Joaquin Valley of California. The evaluation instrument was used to observe these teachers teach elementary science lessons to classrooms of predominately English Learners. The frequency of the use of the ELD/SDAIE instructional strategies were noted on the evaluation instrument with a check mark, indicating the fact that an instructional technique was employed by the teacher. These observation visits revealed what type of instructional strategies were being utilized in the teaching of science to fifth grade English Learners, whether these CLAD-certified teachers were using ELD strategies, and whether the incidence of ELD/SDAIE constructivist instructional techniques increased with the repeated use of the evaluation instrument. As a result of this study, an evaluation instrument to be utilized by school administrators in the evaluation of elementary science instruction to English Learners was developed. The repeated use of this evaluation instrument coupled with preobservation and postobservation conferences may result in the increase in frequency of ELD/SDAIE methodology and constructivist strategies listed on the evaluation instrument in the elementary science classroom.
ERIC Educational Resources Information Center
Rahn, Rhonda N.; Pruitt, Buster; Goodson, Patricia
2016-01-01
Objective: To analyze the literature in which researchers have utilized the National College Health Assessment (NCHA) I or the NCHA II. Participants and Methods: The authors selected peer-reviewed articles published between 2004 and July 2013 utilizing a single search term: National College Health Assessment. Articles were assessed for instrument…
Satellite remote sensing of the ocean
NASA Technical Reports Server (NTRS)
Fu, Lee-Lueng; Liu, W. T.; Abbott, Mark R.
1990-01-01
A concise description of the principles and applications of several selected instruments that have been utilized most frequently in remote sensing of the ocean from satellites is presented. Emphasis is placed on the current progress in oceanographic applications and the outlook of the instruments in future oceanographic satellite missions is discussed. The instruments under discussion are placed into three groups: active microwave sensors, passive ocean color and infrared sensors, and passive microwave sensors.
ERIC Educational Resources Information Center
Boone, William J.; Townsend, J. Scott; Staver, John
2011-01-01
Over many decades, science education researchers have developed, validated, and used a wide range of attitudinal instruments. Data from such instruments have been analyzed, results have been published, and public policies have been influenced. Unfortunately, most science education instruments are not developed using a guiding theoretical…
14 CFR 29.1321 - Arrangement and visibility.
Code of Federal Regulations, 2011 CFR
2011-01-01
...— (1) The instrument that most effectively indicates attitude must be on the panel in the top center... directly below the attitude instrument; (3) The instrument that most effectively indicates airspeed must be adjacent to and to the left of the attitude instrument; and (4) The instrument that most effectively...
14 CFR 29.1321 - Arrangement and visibility.
Code of Federal Regulations, 2012 CFR
2012-01-01
...— (1) The instrument that most effectively indicates attitude must be on the panel in the top center... directly below the attitude instrument; (3) The instrument that most effectively indicates airspeed must be adjacent to and to the left of the attitude instrument; and (4) The instrument that most effectively...
14 CFR 29.1321 - Arrangement and visibility.
Code of Federal Regulations, 2013 CFR
2013-01-01
...— (1) The instrument that most effectively indicates attitude must be on the panel in the top center... directly below the attitude instrument; (3) The instrument that most effectively indicates airspeed must be adjacent to and to the left of the attitude instrument; and (4) The instrument that most effectively...
14 CFR 29.1321 - Arrangement and visibility.
Code of Federal Regulations, 2014 CFR
2014-01-01
...— (1) The instrument that most effectively indicates attitude must be on the panel in the top center... directly below the attitude instrument; (3) The instrument that most effectively indicates airspeed must be adjacent to and to the left of the attitude instrument; and (4) The instrument that most effectively...
14 CFR 29.1321 - Arrangement and visibility.
Code of Federal Regulations, 2010 CFR
2010-01-01
...— (1) The instrument that most effectively indicates attitude must be on the panel in the top center... directly below the attitude instrument; (3) The instrument that most effectively indicates airspeed must be adjacent to and to the left of the attitude instrument; and (4) The instrument that most effectively...
Horwitz, Daniel S; Richard, Raveesh D; Suk, Michael
2014-01-01
Orthopaedic journals, such as the Journal of Orthopaedic Trauma, frequently publish studies reporting functional outcome instruments, but little information has been provided regarding the validity and overall strength of these instruments. This study analyzes the trends in reported functional outcome instruments in articles published in the Journal of Orthopaedic Trauma over a 5-year period and examines the utilization rate, "overall" strength, and validity of these functional outcome instruments for the populations being studied. Articles that were published in the Journal of Orthopaedic Trauma from January 2006 to December 2010 were reviewed, and each article was assigned to 1 of 4 different categories, based on the subspecialty focus and body region. The total number of articles reporting the use of functional outcome instruments, articles with at least 1 functional outcome instrument found in the AO Handbook, and the total number of functional outcome instruments reported were recorded. Each functional outcome instrument was assigned to 1 of 3 categories (generic, nonvalidated, validated), and each validated instrument was also examined to determine whether the category of interest for which it was used was one in which it was previously validated in. A total of 171 articles (34%) of the articles initially reviewed met the inclusion criteria. The average number of articles per year that reported functional outcome instruments was 56% (range, 47%-65%), and the average number of articles that reported at least 1 validated outcome instrument was 51% (range, 44%-61%). The average percentage of validated scores that were appropriately used within the category of interest was 23% (range, 13%-41%). Even though the 56% utilization rate of functional outcome instruments in The Journal of Orthopaedic Trauma is much higher than other journals, it is still low given the importance of measuring and attaining excellent functional outcomes. It is clear that future effort should be given to validating outcome measures for correct evaluation of orthopaedic trauma patients.
Registered indians and tobacco taxation: a culturally-appropriate strategy?
Wardman, A E Dennis; Khan, Nadia A
2005-01-01
Taxation of tobacco is a widely-used strategy that prompts smoking cessation among adults and reduces cigarette consumption among continuing smokers. Registered Indian tobacco use prevalence is at least double that of the rest of Canadians and is in part due to the lower cost of tobacco products purchased on reserve by Registered Indians (RIs) as they are tax exempt. Although registered Indian communities have the ability to collect tax on tobacco products and direct the use of these revenues, this strategy is rarely utilized. Tobacco taxation could have substantial health and economic benefits to RI communities, but perhaps is not culturally-appropriate. In order to better support RI communities, governments and other organizations need to examine this policy instrument in the context of RI populations.
Advance statements in the new Victorian Mental Health Act.
Saraf, Sudeep
2015-06-01
There is growing recognition of the utility of advance statements in the area of mental health. The definition of advance statements and procedure for making and varying advance statements under the Victorian legislation is described. The implications for psychiatrists, mental health tribunals and the process should the psychiatrist vary their decision from that made in the advance statement are discussed. Advance statements being enshrined in legislation is another step in the direction of recovery-oriented service provision for persons with mental illness. The challenge for services will be to develop systems and processes that promote increased uptake of these instruments to empower persons with mental illness to participate in their treatment. © The Royal Australian and New Zealand College of Psychiatrists 2015.
NASA Technical Reports Server (NTRS)
Heath, Donald F.; Ahmad, Zia
2001-01-01
In the early 1990s a series of surface-based direct sun and zenith sky measurements of total column ozone were made with SBUV/2 flight models and the SSBUV Space Shuttle instrument in Boulder, Colorado which were compared with NOAA Dobson Instrument direct sun observations and TOMS instrument overpass observations of column ozone. These early measurements led to the investigation of the accuracy of derived total column ozone amounts and aerosol optical depths from zenith sky observations. Following the development and availability of radiometrically stable IAD narrow band interference filter and nitrided silicon photodiodes a simple compact multifilter spectroradiometer was developed which can be used as a calibration transfer standard spectroradiometer (CTSS) or as a surface based instrument remote sensing instruments for measurements of total column ozone and aerosol optical depths. The total column ozone derived from zenith sky observations agrees with Dobson direct sun AD double wavelength pair measurements and with TOMS overpass ozone amounts within uncertainties of about 1%. When used as a calibration transfer standard spectroradiometer the multifilter spectroradiometer appears to be capable of establishing instrument radiometric calibration uncertainties of the order of 1% or less relative to national standards laboratory radiometric standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... requiring a written directive. The training must include— (i) Radiation physics and instrumentation; (ii... control procedures on instruments used to determine the activity of dosages and performing checks for...
Arnold, David; Girling, Alan; Stevens, Andrew; Lilford, Richard
2009-07-22
Utilities (values representing preferences) for healthcare priority setting are typically obtained indirectly by asking patients to fill in a quality of life questionnaire and then converting the results to a utility using population values. We compared such utilities with those obtained directly from patients or the public. Review of studies providing both a direct and indirect utility estimate. Papers reporting comparisons of utilities obtained directly (standard gamble or time tradeoff) or indirectly (European quality of life 5D [EQ-5D], short form 6D [SF-6D], or health utilities index [HUI]) from the same patient. PubMed and Tufts database of utilities. Sign test for paired comparisons between direct and indirect utilities; least squares regression to describe average relations between the different methods. Mean utility scores (or median if means unavailable) for each method, and differences in mean (median) scores between direct and indirect methods. We found 32 studies yielding 83 instances where direct and indirect methods could be compared for health states experienced by adults. The direct methods used were standard gamble in 57 cases and time trade off in 60(34 used both); the indirect methods were EQ-5D (67 cases), SF-6D (13), HUI-2 (5), and HUI-3 (37). Mean utility values were 0.81 (standard gamble) and 0.77 (time tradeoff) for the direct methods; for the indirect methods: 0.59(EQ-5D), 0.63 (SF-6D), 0.75 (HUI-2) and 0.68 (HUI-3). Direct methods of estimating utilities tend to result in higher health ratings than the more widely used indirect methods, and the difference can be substantial.Use of indirect methods could have important implications for decisions about resource allocation: for example, non-lifesaving treatments are relatively more favoured in comparison with lifesaving interventions than when using direct methods.
14 CFR 27.1303 - Flight and navigation instruments.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 27.1303... navigation instruments. The following are the required flight and navigation instruments: (a) An airspeed indicator. (b) An altimeter. (c) A magnetic direction indicator. ...
14 CFR 27.1303 - Flight and navigation instruments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight and navigation instruments. 27.1303... navigation instruments. The following are the required flight and navigation instruments: (a) An airspeed indicator. (b) An altimeter. (c) A magnetic direction indicator. ...
Pilot performance and heart rate during in-flight use of a compact instrument display.
DOT National Transportation Integrated Search
1975-11-01
Instrument panels in many general aviation aircraft are becoming increasingly crowded, presenting the pilot with an instrument scanning problem. Because most aircraft instruments require use of central (foveal) vision, the pilot must look directly at...
Clinical utility of an automated instrument for gram staining single slides.
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-06-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.
Lee, Han-Dong; Jeon, Chang-Hoon; Chung, Nam-Su; Seo, Young-Wook
2017-08-01
A cost-utility analysis (CUA). The aim of this study was to determine the cost-effectiveness of pedicle screw removal after posterior fusion in thoracolumbar burst fractures. Pedicle screw instrumentation is a standard fixation method for unstable thoracolumbar burst fracture. However, removal of the pedicle screw after successful fusion remains controversial because the clinical benefits remain unclear. CUA can help clinicians make appropriate decisions about optimal health care for pedicle screw removal after successful fusion in thoracolumbar burst fractures. We conducted a single-center, retrospective, longitudinal matched-cohort study of prospectively collected outcomes. In total, 88 consecutive patients who had undergone pedicle screw instrumentation for thoracolumbar burst fracture with successful fusion confirmed by computed tomography (CT) were used in this study. In total, 45 patients wanted to undergo implant removal surgery (R group), and 43 decided not to remove the implant (NR group). A CUA was conducted from the health care perspective. The direct costs of health care were obtained from the medical bill of each patient. Changes in health-related quality of life (HRQoL) scores, validated by Short Form 6D, were used to calculate quality-adjusted life-years (QALYs). Total costs and gained QALY were calculated at 1 year (1 year) and 2 years (2 years) compared with baseline. Results are expressed as an incremental cost-effectiveness ratio (ICER). Different discount rates (0%, 3%, and 5%) were applied to both cost and QALY for sensitivity analysis. Baseline patient variables were similar between the two groups (all P > 0.05). The additional benefits of implant removal (0.201 QALY at 2 years) were achieved with additional costs ($2541 at 2 years), equating to an ICER of $12,641/QALY. On the basis of the different discount rates, the robustness of our study's results was also determined. Implant removal after successful fusion in a thoracolumbar burst fracture is cost-effective until postoperative year 2. 3.
MIOSAT Mission Scenario and Design
NASA Astrophysics Data System (ADS)
Agostara, C.; Dionisio, C.; Sgroi, G.; di Salvo, A.
2008-08-01
MIOSAT ("Mssione Ottica su microSATellite") is a low-cost technological / scientific microsatellite mission for Earth Observation, funded by Italian Space Agency (ASI) and managed by a Group Agreement between Rheinmetall Italia - B.U. Spazio - Contraves as leader and Carlo Gavazzi Space as satellite manufacturer. Several others Italians Companies, SME and Universities are involved in the development team with crucial roles. MIOSAT is a microsatellite weighting around 120 kg and placed in a 525 km altitude sun-synchronuos circular LEO orbit. The microsatellite embarks three innovative optical payloads: Sagnac multi spectral radiometer (IFAC-CNR), Mach Zehender spectrometer (IMM-CNR), high resolution pancromatic camera (Selex Galileo). In addition three technological experiments will be tested in-flight. The first one is an heat pipe based on Marangoni effect with high efficiency. The second is a high accuracy Sun Sensor using COTS components and the last is a GNSS SW receiver that utilizes a Leon2 processor. Finally a new generation of 28% efficiency solar cells will be adopted for the power generation. The platform is highly agile and can tilt along and cross flight direction. The pointing accuracy is in the order of 0,1° for each axe. The pointing determination during images acquisition is <0,02° for the axis normal to the boresight and 0,04° for the boresight. This paper deals with MIOSAT mission scenario and definition, highlighting trade-offs for mission implementation. MIOSAT mission design has been constrained from challenging requirements in terms of satellite mass, mission lifetime, instrument performance, that have implied the utilization of satellite agility capability to improve instruments performance in terms of S/N and resolution. The instruments provide complementary measurements that can be combined in effective ways to exploit new applications in the fields of atmosphere composition analysis, Earth emissions, antropic phenomena, etc. The Mission is currently in phase B and the launch is planned for 2011.
NASA Technical Reports Server (NTRS)
Fournelle, John; Carpenter, Paul
2006-01-01
Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.
VizieR Online Data Catalog: Stellar mass of brightest cluster galaxies (Bellstedt+, 2016)
NASA Astrophysics Data System (ADS)
Bellstedt, S.; Lidman, C.; Muzzin, A.; Franx, M.; Guatelli, S.; Hill, A. R.; Hoekstra, H.; Kurinsky, N.; Labbe, I.; Marchesini, D.; Marsan, Z. C.; Safavi-Naeini, M.; Sifon, C.; Stefanon, M.; van de Sande, J.; van Dokkum, P.; Weigel, C.
2017-11-01
We utilize a sample of 98 newly imaged galaxy clusters from the RELICS (REd Lens Infrared Cluster Survey) survey within this study. The data were collected during six observing runs on three instruments over a period spanning from 2013 October to 2015 March. The instruments utilized were the SofI2 camera on the New Technology Telescope at the European Southern Observatory (ESO) La Silla Observatory in Chile, WHIRC3 on the WIYN telescope at the Kitt Peak National Observatory and LIRIS4 on the William Herschel Telescope (WHT) in La Palma, Spain. (2 data files).
Direct measurements of bed stress under swash in the field
NASA Astrophysics Data System (ADS)
Conley, Daniel C.; Griffin, John G.
2004-03-01
Utilizing flush mounted hot film anemometry, the bed stress under swash was measured directly in a field experiment conducted on Barret Beach, Fire Island, New York. The theory, development, and calibration of the instrument package are discussed, and results from the field experiment are presented. Examples of bed stress time series throughout a swash cycle are presented, and an ensemble averaged swash bed stress cycle is calculated. Strong asymmetry is observed between the uprush and backwash phases of the swash flow. The maximum bed shear stress exerted by the uprush is approximately double that of the backwash, while the duration of the backwash is 135% greater than that of the uprush. Friction coefficients in the swash zone are observed to be similar in magnitude to those from steady flow, with the mean observed friction coefficient equal to 0.0037. Swash friction coefficients derived from the current measurements exhibit a Reynolds number dependence similar to that observed for other flows. A systematic difference between coefficients for uprush and backwash is suggested.
Diagnosis of borderline personality disorder in China: current status and future directions.
Zhong, Jie; Leung, Freedom
2009-02-01
This paper reviews the current status and future directions of borderline personality disorder (BPD) research in China. Although the committee of the third version of the Chinese Classification of Mental Disorders (CCMD-3) rejected BPD as a valid diagnostic category and instead adopted the term impulsive personality disorder (IPD), our literature review on personality disorders from 1979 to 2008 in China indicated that BPD was the most popular research topic among researchers and clinicians. Available empiric evidence on BPD in China provided preliminary support for the construct validity and clinical utility of BPD in clinical and nonclinical Chinese samples. Future studies in the following areas are suggested: 1) developing reliable assessment instruments for measuring BPD pathology in China, 2) comparing the construct validity and phenomenology of CCMD IPD and DSM BPD among Chinese patients, 3) examining potential cultural differences in symptom expression of BPD pathology among the Chinese, and 4) exploring indigenous and imported methods for treating BPD patients in China.
System Design of One-chip Wave Particle Interaction Analyzer for SCOPE mission.
NASA Astrophysics Data System (ADS)
Fukuhara, Hajime; Ueda, Yoshikatsu; Kojima, Hiro; Yamakawa, Hiroshi
In past science spacecrafts such like GEOTAIL, we usually capture electric and magnetic field waveforms and observe energetic eletron and ion particles as velocity distributions by each sensor. We analyze plasma wave-particle interactions by these respective data and the discussions are sometimes restricted by the difference of time resolution and by the data loss in desired regions. One-chip Wave Particle Interaction Analyzer (OWPIA) conducts direct quantitative observations of wave-particle interaction by direct 'E dot v' calculation on-board. This new instruments have a capability to use all plasma waveform data and electron particle informations. In the OWPIA system, we have to calibrate the digital observation data and transform the same coordinate system. All necessary calculations are processed in Field Programmable Gate Array(FPGA). In our study, we introduce a basic concept of the OWPIA system and a optimization method for each calculation functions installed in FPGA. And we also discuss the process speed, the FPGA utilization efficiency, the total power consumption.
Method and apparatus for determining time, direction, and composition of impacting space particles
NASA Technical Reports Server (NTRS)
Kinard, William H. (Inventor); Wortman, Jim J. (Inventor); Kassel, Philip C., Jr. (Inventor); Singer, Fred S. (Inventor); Humes, Donald H. (Inventor); Stanley, John E. (Inventor)
1990-01-01
A space particle collector for recording the time specific particles are captured, and its direction at the time of capture, utilizes an array of targets, each comprised of an MOS capacitor on a chip charged from an external source and discharged upon impact by a particle through a tab on the chip that serves as a fuse. Any impacting particle creates a crater, but only the first will cause a discharge of the capacitor. A substantial part of the metal film around the first crater is burned off by the discharge current. The time of the impulse which burns the tab, and the identification of the target, is recorded together with data from flight instruments. The metal film is partitioned into pie sections to provide a plurality of targets on each of an array of silicon wafers, thus increasing the total number of identified particles that can be collected. It is thus certain which particles were captured at what specific times.
Kennedy Axis V: Clinimetric properties assessed by mental health nurses.
Faay, Margo D M; van de Sande, Roland; Gooskens, Floor; Hafsteinsdóttir, Thóra B
2013-10-01
The Kennedy Axis V is a routine outcome measurement instrument which can assist the assessment of the short-term risk for violence and other adverse patient outcomes. The purpose of this study was to evaluate the interrater reliability and clinical utility of the instrument when used by mental health nurses in daily care of patients with mental illness. This cross-sectional study was conducted in inpatient and outpatient adult psychiatric care units and in one adolescent inpatient unit at a university hospital in the Netherlands. Interrater reliability was measured based on the independent scores of two different nurses for the same patients. The clinical utility of the instrument was evaluated by means of a clinical utility questionnaire. To gain a deeper understanding of rating difficulties at the adolescent unit, additional data were collected in two focus group interviews. The overall results revealed a substantial level of agreement between nurses (intraclass correlation coefficient and Pearson 0.79). Some rating challenges were identified, including difficulties with scoring the instrument and using tailor-made interventions related to the scores. These challenges can be resolved using refined training and implementation strategies. When the Kennedy Axis V is accompanied by a solid implementation strategy in adult mental health care, the instrument can be used for short-term risk assessment and thereby contribute in efforts to reduce violence, suicide, self-harm, severe self-neglect, and enhanced objectivity in clinical decision-making. © 2012 The Authors; International Journal of Mental Health Nursing © 2012 Australian College of Mental Health Nurses Inc.
Vavken, Patrick; Ganal-Antonio, Anne Kathleen B.; Quidde, Julia; Shen, Francis H.; Chapman, Jens R.; Samartzis, Dino
2015-01-01
Study Design A broad narrative review. Objectives Outcome assessment in spinal disorders is imperative to help monitor the safety and efficacy of the treatment in an effort to change the clinical practice and improve patient outcomes. The following article, part two of a two-part series, discusses the various outcome tools and instruments utilized to address spinal disorders and their management. Methods A thorough review of the peer-reviewed literature was performed, irrespective of language, addressing outcome research, instruments and tools, and applications. Results Numerous articles addressing the development and implementation of health-related quality-of-life, neck and low back pain, overall pain, spinal deformity, and other condition-specific outcome instruments have been reported. Their applications in the context of the clinical trial studies, the economic analyses, and overall evidence-based orthopedics have been noted. Additional issues regarding the problems and potential sources of bias utilizing outcomes scales and the concept of minimally clinically important difference were discussed. Conclusion Continuing research needs to assess the outcome instruments and tools used in the clinical outcome assessment for spinal disorders. Understanding the fundamental principles in spinal outcome assessment may also advance the field of “personalized spine care.” PMID:26225283
NASA Astrophysics Data System (ADS)
Seely, J. F.; McMullin, D. R.; Bremer, J.; Chang, C.; Sakdinawat, A.; Jones, A. R.; Vest, R.
2014-12-01
Two solar instrument designs are presented that utilize newly developed miniature free-standing zone plates having interconnected Au opaque bars and no support membrane resulting in excellent long-term stability in space. Both instruments are based on a zone plate having 4 mm outer diameter and 1 to 2 degree field of view. The zone plate collects EUV radiation and focuses a narrow bandpass through a pinhole aperture and onto a silicon photodiode detector. As a miniature radiometer, EUV irradiance is accurately determined from the zone plate efficiency and the photodiode responsivity that are calibrated at the NIST SURF synchrotron facility. The EUV radiometer is pointed to the Sun and measures the absolute solar EUV irradiance in high time cadence suitable for solar physics and space weather applications. As a limb-scanning instrument in low earth orbit, a miniature zone-plate monochromator measures the extinction of solar EUV radiation by scattering through the upper atmosphere which is a measure of the variability of the ionosphere. Both instruments are compact and light-weight and are attractive for CubeSats and other missions where resources are extremely limited.
Reliability and validity in a nutshell.
Bannigan, Katrina; Watson, Roger
2009-12-01
To explore and explain the different concepts of reliability and validity as they are related to measurement instruments in social science and health care. There are different concepts contained in the terms reliability and validity and these are often explained poorly and there is often confusion between them. To develop some clarity about reliability and validity a conceptual framework was built based on the existing literature. The concepts of reliability, validity and utility are explored and explained. Reliability contains the concepts of internal consistency and stability and equivalence. Validity contains the concepts of content, face, criterion, concurrent, predictive, construct, convergent (and divergent), factorial and discriminant. In addition, for clinical practice and research, it is essential to establish the utility of a measurement instrument. To use measurement instruments appropriately in clinical practice, the extent to which they are reliable, valid and usable must be established.
Geostationary earth climate sensor: Scientific utility and feasibility, phase A
NASA Technical Reports Server (NTRS)
Campbell, G. Garrett; Vonderharr, T. H.; Evert, T.; Kidder, Stanley Q.; Purdom, James F. W.
1991-01-01
The possibility of accurate broad band radiation budget measurements from a GEO platform will provide a unique opportunity for viewing radiation processes in the atmosphere-ocean system. The CSU/TRW team has prepared a Phase 1 instrument design study demonstrating that measurements of radiation budget are practical from geosynchronous orbit with proven technology. This instrument concept is the Geostationary Earth Climate Sensor (GECS). A range of resolutions down to 20 km at the top of the atmosphere are possible, depending upon the scientific goals of the experiment. These tradeoffs of resolution and measurement repeat cycles are examined for scientific utility. The design of a flexible instrument is shown to be possible to meet the two goals: long-term, systematic monitoring of the diurnal cycles of radiation budget; and high time and space resolution studies of regional radiation features.
Mass spectrometry in the U.S. space program: past, present, and future.
Palmer, P T; Limero, T F
2001-06-01
Recent years have witnessed significant progress on the miniaturization of mass spectrometers for a variety of field applications. This article describes the development and application of mass spectrometry (MS) instrumentation to support of goals of the U.S. space program. Its main focus is on the two most common space-related applications of MS: studying the composition of planetary atmospheres and monitoring air quality on manned space missions. Both sets of applications present special requirements in terms of analytical performance (sensitivity, selectivity, speed, etc.), logistical considerations (space, weight, and power requirements), and deployment in perhaps the harshest of all possible environments (space). The MS instruments deployed on the Pioneer Venus and Mars Viking Lander missions are reviewed for the purposes of illustrating the unique features of the sample introduction systems, mass analyzers, and vacuum systems, and for presenting their specifications which are impressive even by today's standards. The various approaches for monitoring volatile organic compounds (VOCs) in cabin atmospheres are also reviewed. In the past, ground-based GC/MS instruments have been used to identify and quantify VOCs in archival samples collected during the Mercury, Apollo, Skylab, Space Shuttle, and Mir missions. Some of the data from the more recent missions are provided to illustrate the composition data obtained and to underscore the need for instrumentation to perform such monitoring in situ. Lastly, the development of two emerging technologies, Direct Sampling Ion Trap Mass Spectrometry (DSITMS) and GC/Ion Mobility Spectrometry (GC/IMS), will be discussed to illustrate their potential utility for future missions. c 2001 American Society for Mass Spectrometry.
James, Alex S; Pennington, Zachary T; Tran, Phu; Jentsch, James David
2015-01-01
Two theories regarding the role for dopamine neurons in learning include the concepts that their activity serves as a (1) mechanism that confers incentive salience onto rewards and associated cues and/or (2) contingency teaching signal reflecting reward prediction error. While both theories are provocative, the causal role for dopamine cell activity in either mechanism remains controversial. In this study mice that either fully or partially lacked NMDARs in dopamine neurons exclusively, as well as appropriate controls, were evaluated for reward-related learning; this experimental design allowed for a test of the premise that NMDA/glutamate receptor (NMDAR)-mediated mechanisms in dopamine neurons, including NMDA-dependent regulation of phasic discharge activity of these cells, modulate either the instrumental learning processes or the likelihood of pavlovian cues to become highly motivating incentive stimuli that directly attract behavior. Loss of NMDARs in dopamine neurons did not significantly affect baseline dopamine utilization in the striatum, novelty evoked locomotor behavior, or consumption of a freely available, palatable food solution. On the other hand, animals lacking NMDARs in dopamine cells exhibited a selective reduction in reinforced lever responses that emerged over the course of instrumental learning. Loss of receptor expression did not, however, influence the likelihood of an animal acquiring a pavlovian conditional response associated with attribution of incentive salience to reward-paired cues (sign tracking). These data support the view that reductions in NMDAR signaling in dopamine neurons affect instrumental reward-related learning but do not lend support to hypotheses that suggest that the behavioral significance of this signaling includes incentive salience attribution.
Mass spectrometry in the U.S. space program: past, present, and future
NASA Technical Reports Server (NTRS)
Palmer, P. T.; Limero, T. F.
2001-01-01
Recent years have witnessed significant progress on the miniaturization of mass spectrometers for a variety of field applications. This article describes the development and application of mass spectrometry (MS) instrumentation to support of goals of the U.S. space program. Its main focus is on the two most common space-related applications of MS: studying the composition of planetary atmospheres and monitoring air quality on manned space missions. Both sets of applications present special requirements in terms of analytical performance (sensitivity, selectivity, speed, etc.), logistical considerations (space, weight, and power requirements), and deployment in perhaps the harshest of all possible environments (space). The MS instruments deployed on the Pioneer Venus and Mars Viking Lander missions are reviewed for the purposes of illustrating the unique features of the sample introduction systems, mass analyzers, and vacuum systems, and for presenting their specifications which are impressive even by today's standards. The various approaches for monitoring volatile organic compounds (VOCs) in cabin atmospheres are also reviewed. In the past, ground-based GC/MS instruments have been used to identify and quantify VOCs in archival samples collected during the Mercury, Apollo, Skylab, Space Shuttle, and Mir missions. Some of the data from the more recent missions are provided to illustrate the composition data obtained and to underscore the need for instrumentation to perform such monitoring in situ. Lastly, the development of two emerging technologies, Direct Sampling Ion Trap Mass Spectrometry (DSITMS) and GC/Ion Mobility Spectrometry (GC/IMS), will be discussed to illustrate their potential utility for future missions. c 2001 American Society for Mass Spectrometry.
Determination of Cinnamaldehyde in Cinnamon by SPME-GC-MS: An Instrumental Analysis Experiment
ERIC Educational Resources Information Center
Wang, Yimin; Ocariz, Jessica; Hammersand, Jennifer; MacDonald, Evan; Bartczak, Ashley; Kero, Frank; Young, Vaneica Y.; Williams, Kathryn R.
2008-01-01
Students analyze "trans"-cinnamaldehyde in commercial cinnamon using solid-phase microextraction and GC-MS with ethyl benzoate as the internal standard. Aside from the instrumentation, the experiment utilizes readily available low hazard materials and can be completed within one four-hour laboratory period. (Contains 2 figures.)
Investigating the Structure of the Pediatric Symptoms Checklist in the Preschool Setting
ERIC Educational Resources Information Center
DiStefano, Christine; Liu, Jin; Burgess, Yin
2017-01-01
When using educational/psychological instruments, psychometric investigations should be conducted before adopting to new environments to ensure that an instrument measures the same constructs. Exploratory structural equation modeling and confirmatory factor analysis methods were used to examine the utility of the short form of the Pediatric…
76 FR 44927 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-27
... proposed information collection project: ``Pre-test of an Assisted Living Consensus Instrument.'' In... Pre-Test of an Assisted Living Consensus Instrument Using a consensus-based process and in partnership... utilized for the survey pre-test, and to obtain the name of the Administrator or Executive Director of the...
Academic and Recreational Reading Motivation of Teacher Candidates
ERIC Educational Resources Information Center
Lancellot, Michael
2017-01-01
The purpose of this mixed methods study was to determine relationships among teacher candidates' academic and recreational reading motivation. This study utilized a previously designed, reliable, and valid instrument called the Adult Reading Motivation Scale with permission from Schutte and Malouff (2007). The instrument included a pool of 50…
14 CFR 23.1303 - Flight and navigation instruments.
Code of Federal Regulations, 2012 CFR
2012-01-01
... navigation instruments. (c) A magnetic direction indicator. ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 23.1303... General § 23.1303 Flight and navigation instruments. Link to an amendment published at 76 FR 75760...
The problems and abuse of performance bond in the construction Industry
NASA Astrophysics Data System (ADS)
Hassan, A. A.; Adnan, H.
2018-02-01
Performance bond is a bank-origin system adopted in the construction industry to act as a tool to ensure project delivery. The bond is taken up by an obliging party with endorsement by a third party; normally a banking institution, which would warrants the release of an insured amount should the obliging party fails to complete the contracted work on time or as agreed. The nature of the instrument is said to be perplexed and abusive. The research aims to investigate this claim. Applied legal research using both doctrinal and non-doctrinal legal research is employed. With the application of deductive reasoning, the data is processed and summarized. It is found that the term bond and guarantee, which are used intermittently but equivocally by the parties, should be distinguished accordingly to its obligation values, or otherwise would trigger major disputes. Interpretation, drafting and liabilities issues caused by archaic language and dated recycled wordings in the contracts contributed nothing to the convenience and application of this instrument. The loopholes in the contract made it easy for suspected fraudulent calls to be made by the beneficiary, whom are normally, the client. With several trusted professional bodies discouraged the use of this instrument, the legal system is compelled to provide direction to ensure continuous utilization of this project delivery assurance mechanism. Standardized system and structure is vital in order to obtain uniformity in its application.
NASA Astrophysics Data System (ADS)
Harris, W. M.; Scope Team
2003-04-01
The Solar Connections Observatory for Planetary Environments (SCOPE) is a remote sensing facility designed to probe the nature of the relationship of planetary bodies and the local interstellar medium to the solar wind and UV-EUV radiation field. In particular, the SCOPE program seeks to comparatively monitor the near space environments and thermosphere/ionospheres of planets, planetesimals, and satellites under different magnetospheric configurations and as a function of heliocentric distance and solar activity. In addition, SCOPE will include the Earth as a science target, providing new remote observations of auroral and upper atmospheric phenomena and utilizing it as baseline for direct comparison with other planetary bodies. The observatory will be scheduled into discrete campaigns interleaving Target-Terrestrial observations to provide a comparative annual activity map over the course of a solar half cycle. The SCOPE science instrument consists of binocular UV (115-310 nm) and EUV (500-120 nm) telescopes and a side channel sky-mapping interferometer on a spacecraft stationed in a remote orbit. The telescope instruments provide a mix of capabilities including high spatial resolution narrow band imaging, moderate resolution broadband spectro-imaging, and high-resolution line spectroscopy. The side channel instrument will be optimized for line profile measurements of diagnostic terrestrial upper atmospheric, comet, interplanetary, and interstellar extended emissions.
Aircraft Power-Plant Instruments
NASA Technical Reports Server (NTRS)
Sontag, Harcourt; Brombacher, W G
1934-01-01
This report supersedes NACA-TR-129 which is now obsolete. Aircraft power-plant instruments include tachometers, engine thermometers, pressure gages, fuel-quantity gages, fuel flow meters and indicators, and manifold pressure gages. The report includes a description of the commonly used types and some others, the underlying principle utilized in the design, and some design data. The inherent errors of the instrument, the methods of making laboratory tests, descriptions of the test apparatus, and data in considerable detail in the performance of commonly used instruments are presented. Standard instruments and, in cases where it appears to be of interest, those used as secondary standards are described. A bibliography of important articles is included.
Optical links in the angle-data assembly of the 70-meter antennas
NASA Technical Reports Server (NTRS)
Nelson, M. D.; Schroeder, J. R.; Tubbs, E. F.
1988-01-01
In the precision-pointing mode the 70 meter antennas utilize an optical link provided by an autocollimator. In an effort to improve reliability and performance, commercial instruments were evaluated as replacement candidates, and upgraded versions of the existing instruments were designed and tested. The latter were selected for the Neptune encounter, but commercial instruments with digital output show promise of significant performance improvement for the post-encounter period.
ERIC Educational Resources Information Center
Burgdorf, Kenneth; White, Kristine
This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…
Imaging Planet Formation Inside the Diffraction Limit
NASA Astrophysics Data System (ADS)
Sallum, Stephanie Elise
For decades, astronomers have used observations of mature planetary systems to constrain planet formation theories, beginning with our own solar system and now the thousands of known exoplanets. Recent advances in instrumentation have given us a direct view of some steps in the planet formation process, such as large-scale protostar and protoplanetary disk features and evolution. However, understanding the details of how planets accrete and interact with their environment requires direct observations of protoplanets themselves. Transition disks, protoplanetary disks with inner clearings that may be caused by forming planets, are the best targets for these studies. Their large distances, compared to the stars normally targeted for direct imaging of exoplanets, make protoplanet detection difficult and necessitate novel imaging techniques. In this dissertation, I describe the results of using non-redundant masking (NRM) to search for forming planets in transition disk clearings. I first present a data reduction pipeline that I wrote to this end, using example datasets and simulations to demonstrate reduction and imaging optimizations. I discuss two transition disk NRM case studies: T Cha and LkCa 15. In the case of T Cha, while we detect significant asymmetries, the data cannot be explained by orbiting companions. The fluxes and orbital motion of the LkCa 15 companion signals, however, can be naturally explained by protoplanets in the disk clearing. I use these datasets and simulated observations to illustrate the effects of scattered light from transition disk material on NRM protoplanet searches. I then demonstrate the utility of the dual-aperture Large Binocular Telescope Interferometer's NRM mode on the bright B[e] star MWC 349A. I discuss the implications of this work for planet formation studies as well as future prospects for NRM and related techniques on next generation instruments.
Hoefman, Renske J; van Exel, Job; Rose, John M; van de Wetering, E J; Brouwer, Werner B F
2014-01-01
Economic evaluations adopting a societal perspective need to include informal care whenever relevant. However, in practice, informal care is often neglected, because there are few validated instruments to measure and value informal care for inclusion in economic evaluations. The CarerQol, which is such an instrument, measures the impact of informal care on 7 important burden dimensions (CarerQol-7D) and values this in terms of general quality of life (CarerQol-VAS). The objective of the study was to calculate utility scores based on relative utility weights for the CarerQol-7D. These tariffs will facilitate inclusion of informal care in economic evaluations. The CarerQol-7D tariff was derived with a discrete choice experiment conducted as an Internet survey among the general adult population in the Netherlands (N = 992). The choice set contained 2 unlabeled alternatives described in terms of the 7 CarerQol-7D dimensions (level range: "no,"some," and "a lot"). An efficient experimental design with priors obtained from a pilot study (N = 104) was used. Data were analyzed with a panel mixed multinomial parameter model including main and interaction effects of the attributes. The utility attached to informal care situations was significantly higher when this situation was more attractive in terms of fewer problems and more fulfillment or support. The interaction term between the CarerQol-7D dimensions physical health and mental health problems also significantly explained this utility. The tariff was constructed by adding up the relative utility weights per category of all CarerQol-7D dimensions and the interaction term. We obtained a tariff providing standard utility scores for caring situations described with the CarerQol-7D. This facilitates the inclusion of informal care in economic evaluations.
[Development of opened instrument for generating and measuring physiological signal].
Chen, Longcong; Hu, Guohu; Gao, Bin
2004-12-01
An opened instrument with liquid crystal display (LCD) for generating and measuring physiological signal is introduced in this paper. Based on a single-chip microcomputer. the instrument uses the technique of LCD screen to display signal wave and information, and it realizes man-machine interaction by keyboard. This instrument can produce not only defined signal in common use by utilizing important saved data and relevant arithmetic, but also user-defined signal. Therefore, it is open to produce signal. In addition, this instrument has strong extension because of its modularized design as computer, which has much function such as displaying, measuring and saving physiological signal, and many features such as low power consumption, small volume, low cost and portability. Hence this instrument is convenient for experiment teaching, clinic examining, maintaining of medical instrument.
Stress prompts habit behavior in humans.
Schwabe, Lars; Wolf, Oliver T
2009-06-03
Instrumental behavior can be controlled by goal-directed action-outcome and habitual stimulus-response processes that are supported by anatomically distinct brain systems. Based on previous findings showing that stress modulates the interaction of "cognitive" and "habit" memory systems, we asked in the presented study whether stress may coordinate goal-directed and habit processes in instrumental learning. For this purpose, participants were exposed to stress (socially evaluated cold pressor test) or a control condition before they were trained to perform two instrumental actions that were associated with two distinct food outcomes. After training, one of these food outcomes was selectively devalued as subjects were saturated with that food. Next, subjects were presented the two instrumental actions in extinction. Stress before training in the instrumental task rendered participants' behavior insensitive to the change in the value of the food outcomes, that is stress led to habit performance. Moreover, stress reduced subjects' explicit knowledge of the action-outcome contingencies. These results demonstrate for the first time that stress promotes habits at the expense of goal-directed performance in humans.
On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework
NASA Technical Reports Server (NTRS)
Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg
2007-01-01
Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).
NASA Astrophysics Data System (ADS)
Espina, Chad Edward Obedoza
The Wildland Urban-Interface Fire Dynamics Simulator (WFDS) is a computer code that is currently being developed by the National Institute of Standards and Technology (NIST). WFDS has the capability of simulating wildland fire behavior with prescribed elements such vegetative and structural fuel, topography, and weather conditions. In this initial stage of the research, support for the development of WFDS focuses on the evaluation of a wind flow simulation on a very complex, outdoor terrain. This effort is preceded by the fabrication, installation and testing of wind-sensing equipment. Foremost, wind data gathered from different sites using various instruments are compared and evaluated. The data gathered in the Trails community of Rancho Bernardo is then presented and compared to select WFDS simulations. Systems consisting of a wind vane and anemometer are currently installed in the Trails community of Rancho Bernardo. They were installed by Professor Fletcher J. Miller and me using a lift that is attached to a telescoping crane. These instruments will gather the wind data needed to show the behavioral patterns of winds influenced by the topography and obstructions such as trees and houses. They are currently installed on top of light posts. These light posts were picked based on the path of the fire influenced by the Santa Ana winds that ravaged the community in 2007. The data from these instruments were graphically represented using a Matlab code that was developed specifically for the data sets. The Matlab graphing utility plots wind speed and wind direction along with matching polar plots. Other main features also include the ability to set a time range and compare two sites in one plot. There are other wind instruments currently being tested and being analyzed to ensure correct data is being recorded. These instruments will also expand to a wider range the wind data-gathering capabilities vertically. A Sound Detecting and Ranging (SoDAR) unit gathers wind speed and direction from the sound waves, initially emitted by the SoDAR to the atmosphere, that are reflected by the air flow above the unit. Wind data has been compared to the SoDAR unit with data from instruments installed on a meteorological tower operated by the National Oceanic and Atmospheric Administration (NOAA) located in northern California. Two more SoDARs are currently in Texas where initially they were deployed 400 meters apart of each other at an airfield. Also in the same airfield, the wind instrument of an Unmanned Aerial Vehicle (UAV) SuperBat was tested and compared to the SoDARs. Lastly, a self-contained wind instrument (Wind Dart) on a UAV that was developed by the University of Colorado was tested. The instrument was used while attached to the UAV Spectra. A static test was also done in San Diego State University's low speed wind tunnel. The wind data comparison from the SoDAR and meteorological tower in Lodi, California showed close tracking to each other both in wind speed and direction. The comparison of the wind data gathered by the two SoDARs in Texas also showed close tracking to each other. As for the Wind Dart, the data gathered from the instrument and UAV Spectra are not conclusive enough to validate the abilities of the Wind Dart. The experimental procedure in testing the Wind Dart on a moving platform must be further developed. Before the aerial test of the Wind Dart, it was first tested at San Diego State University's low speed tunnel. The detected wind speed by the Wind Dart closely matches the prescribed wind speed of the wind tunnel. The data between the UAV SuperBat and SoDARs showed close tracking. Data collected by the Rancho Bernardo wind instruments shows cyclical wind patterns in the neighborhood. Initial evaluation of select WFDS simulations show data that mimics data gathered from the field.
A systematic literature review of health state utility values in head and neck cancer.
Meregaglia, Michela; Cairns, John
2017-09-02
Health state utility values (HSUVs) are essential parameters in model-based economic evaluations. This study systematically identifies HSUVs in head and neck cancer and provides guidance for selecting them from a growing body of health-related quality of life studies. We systematically reviewed the published literature by searching PubMed, EMBASE and The Cochrane Library using a pre-defined combination of keywords. The Tufts Cost-Effectiveness Analysis Registry and the School of Health and Related Research Health Utilities Database (ScHARRHUD) specifically containing health utilities were also queried, in addition to the Health Economics Research Centre database of mapping studies. Studies were considered for inclusion if reporting original HSUVs assessed using established techniques. The characteristics of each study including country, design, sample size, cancer subsite addressed and demographics of responders were summarized narratively using a data extraction form. Quality scoring and critical appraisal of the included studies were performed based on published recommendations. Of a total 1048 records identified by the search, 28 studies qualified for data extraction and 346 unique HSUVs were retrieved from them. HSUVs were estimated using direct methods (e.g. standard gamble; n = 10 studies), multi-attribute utility instruments (MAUIs; n = 13) and mapping techniques (n = 3); two studies adopted both direct and indirect approaches. Within the MAUIs, the EuroQol 5-dimension questionnaire (EQ-5D) was the most frequently used (n = 11), followed by the Health Utility Index Mark 3 (HUI3; n = 2), the 15D (n = 2) and the Short Form-Six Dimension (SF-6D; n = 1). Different methods and types of responders (i.e. patients, healthy subjects, clinical experts) influenced the magnitude of HSUVs for comparable health states. Only one mapping study developed an original algorithm using head and neck cancer data. The identified studies were considered of intermediate quality. This review provides a dataset of HSUVs systematically retrieved from published studies in head and neck cancer. There is currently a lack of research for some disease phases including recurrent and metastatic cancer, and treatment-related complications. In selecting HSUVs for cost-effectiveness modeling purposes, preference should be given to EQ-5D utility values; however, mapping to EQ-5D is a potentially valuable technique that should be further developed in this cancer population.
Development of a surface topography instrument for automotive textured steel plate
NASA Astrophysics Data System (ADS)
Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang
2010-08-01
The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.
14 CFR 29.1303 - Flight and navigation instruments.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 29.1303... navigation instruments. The following are required flight and navigational instruments: (a) An airspeed... sensitive altimeter. (c) A magnetic direction indicator. (d) A clock displaying hours, minutes, and seconds...
40 CFR 98.84 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... by direct weight measurement using the same plant instruments used for accounting purposes, such as... be determined quarterly by direct weight measurement using the same plant instruments used for accounting purposes, such as weigh hoppers, truck weigh scales, or belt weigh feeders. (f) The quantity of...
Development of megapixel HgCdTe detector arrays with 15 micron cutoff
NASA Astrophysics Data System (ADS)
Forrest, William J.; McMurtry, Craig W.; Dorn, Meghan L.; Pipher, Judith; Cabrera, Mario S.
2016-06-01
I. HistoryHgCdTe is a versatile II-VI semiconductor with a direct-bandgap tunable via the Hg:Cd ratio. Hg:Cd ratio = 53:47 (2.5 micron cutoff) was used on the NICMOS instrument on HST and the 2MASS. Increasing Hg:Cd ratio to 70:30 leads to a 5.4 micron cutoff, utilized in NEOWISE and many JWST instruments. Bailey, Wu et al. (1998) motivated extending this technology to 10 microns and beyond. Bacon, McMurtry et al. (2003, 2004) indicated significant progress toward this longwave (LW) goal.Warm-Spitzer has pioneered passive cooling to below 30 K in space, enabling the JWST mission.II. CurrentNASA's proposed NEOcam mission selected HgCdTe with a 10.6 micron cutoff because it promises natural Zodiacal background limited sensitivity with modest cooling (40 K). Teledyne Imaging Systems (TIS) is producing megapixel arrays with excellent performance (McMurtry, Lee, Dorn et al. (2013)) for this mission.III. FutureModest cooling requirements (circa 30 K) coupled with megapixel arrays and LW sensitivity in the thermal IR make HgCdTe attractive for many infrared instruments. For instance, the spectral signature of a terrestrial planet orbiting in the habitable zone of a nearby star will be the deep and wide absorption by CO_2 centered at 15 microns (Seager and Deming, 2010). LW instruments can enhance Solar System missions, such as exploration of the Enceladus geysers (Spencer, Buratti et al. 2006). Passive cooling will be adequate for these missions. Modern ground-based observatories will benefit from infrared capability out to the N band (7.5-13.6 microns). The required detector temperatures (30-40 K) are easily achievable using commercially available mechanical cryo-coolers (refrigerators).IV. Progress to dateTIS is developing megapixel HgCdTe arrays sensitive out to 15 microns under the direction of the University of Rochester. As a first step, we have produced arrays with a 13 micron cutoff. The initial measurements indicate very promising performance. We will present the measurements of dark current, noise, and quantum efficiency for these devices and discuss our plans to reach our 15 micron target wavelength.
Development of megapixel HgCdTe detector arrays with 15 micron cutoff
NASA Astrophysics Data System (ADS)
Forrest, William J.; McMurtry, Craig W.; Dorn, Meghan; Pipher, Judith; Cabrera, Mario S.
2016-10-01
I. HistoryHgCdTe is a versatile II-VI semiconductor with a direct-bandgap tunable via the Hg:Cd ratio. Hg:Cd ratio = 53:47 (2.5 micron cutoff) was used on the NICMOS instrument on HST and the 2MASS. Increasing Hg:Cd ratio to 70:30 leads to a 5.4 micron cutoff, utilized in NEOWISE and many JWST instruments. Bailey, Wu et al. (1998) motivated extending this technology to 10 microns and beyond. Bacon, McMurtry et al. (2003, 2004) indicated significant progress toward this longwave (LW) goal.Warm-Spitzer has pioneered passive cooling to below 30 K in space, enabling the JWST mission.II. CurrentNASA's proposed NEOcam mission selected HgCdTe with a 10.6 micron cutoff because it promises natural Zodiacal background limited sensitivity with modest cooling (40 K). Teledyne Imaging Systems (TIS) is producing megapixel arrays with excellent performance (McMurtry, Lee, Dorn et al. (2013)) for this mission.III. FutureModest cooling requirements (circa 30 K) coupled with megapixel arrays and LW sensitivity in the thermal IR make HgCdTe attractive for many infrared instruments. For instance, the spectral signature of a terrestrial planet orbiting in the habitable zone of a nearby star will be the deep and wide absorption by CO_2 centered at 15 microns (Seager and Deming, 2010). LW instruments can enhance Solar System missions, such as exploration of the Enceladus geysers (Spencer, Buratti et al. 2006). Passive cooling will be adequate for these missions. Modern ground-based observatories will benefit from infrared capability out to the N band (7.5-13.6 microns). The required detector temperatures (30-40 K) are easily achievable using commercially available mechanical cryo-coolers (refrigerators).IV. Progress to dateTIS is developing megapixel HgCdTe arrays sensitive out to 15 microns under the direction of the University of Rochester. As a first step, we have produced arrays with a 13 micron cutoff. The initial measurements indicate very promising performance. We will present the measurements of dark current, noise, and quantum efficiency for these devices and discuss our plans to reach our 15 micron target wavelength.
Information Retrieval from SAGE II and MFRSR Multi-Spectral Extinction Measurements
NASA Technical Reports Server (NTRS)
Lacis, Andrew A.; Hansen, James E. (Technical Monitor)
2001-01-01
Direct beam spectral extinction measurements of solar radiation contain important information on atmospheric composition in a form that is essentially free from multiple scattering contributions that otherwise tend to complicate the data analysis and information retrieval. Such direct beam extinction measurements are available from the solar occultation satellite-based measurements made by the Stratospheric and Aerosol Gas Experiment (SAGE II) instrument and by ground-based Multi-Filter Shadowband Radiometers (MFRSRs). The SAGE II data provide cross-sectional slices of the atmosphere twice per orbit at seven wavelengths between 385 and 1020 nm with approximately 1 km vertical resolution, while the MFRSR data provide atmospheric column measurements at six wavelengths between 415 and 940 nm but at one minute time intervals. We apply the same retrieval technique of simultaneous least-squares fit to the observed spectral extinctions to retrieve aerosol optical depth, effective radius and variance, and ozone, nitrogen dioxide, and water vapor amounts from the SAGE II and MFRSR measurements. The retrieval technique utilizes a physical model approach based on laboratory measurements of ozone and nitrogen dioxide extinction, line-by-line and numerical k-distribution calculations for water vapor absorption, and Mie scattering constraints on aerosol spectral extinction properties. The SAGE II measurements have the advantage of being self-calibrating in that deep space provides an effective zero point for the relative spectral extinctions. The MFRSR measurements require periodic clear-day Langley regression calibration events to maintain accurate knowledge of instrument calibration.
Alcohol demand and risk preference.
Dave, Dhaval; Saffer, Henry
2008-12-01
Both economists and psychologists have studied the concept of risk preference. Economists categorize individuals as more or less risk-tolerant based on the marginal utility of income. Psychologists categorize individuals' propensity towards risk based on harm avoidance, novelty seeking and reward dependence traits. The two concepts of risk are related, although the instruments used for empirical measurement are quite different. Psychologists have found risk preference to be an important determinant of alcohol consumption; however economists have not included risk preference in studies of alcohol demand. This is the first study to examine the effect of risk preference on alcohol consumption in the context of a demand function. The specifications employ multiple waves from the Panel Study of Income Dynamics (PSID) and the Health and Retirement Study (HRS), which permit the estimation of age-specific models based on nationally representative samples. Both of these data sets include a unique and consistent survey instrument designed to directly measure risk preference in accordance with the economist's definition. This study estimates the direct impact of risk preference on alcohol demand and also explores how risk preference affects the price elasticity of demand. The empirical results indicate that risk preference has a significant negative effect on alcohol consumption, with the prevalence and consumption among risk-tolerant individuals being 6-8% higher. Furthermore, the tax elasticity is similar across both risk-averse and risk-tolerant individuals. This suggests that tax policies are as equally effective in deterring alcohol consumption among those who have a higher versus a lower propensity for alcohol use.
Canning, Elizabeth A; Harackiewicz, Judith M
2015-03-01
Social-psychological interventions in education have used a variety of "self-persuasion" or "saying-is-believing" techniques to encourage students to articulate key intervention messages. These techniques are used in combination with more overt strategies, such as the direct communication of messages in order to promote attitude change. However, these different strategies have rarely been systematically compared, particularly in controlled laboratory settings. We focus on one intervention based in expectancy-value theory designed to promote perceptions of utility value in the classroom and test different intervention techniques to promote interest and performance. Across three laboratory studies, we used a mental math learning paradigm in which we varied whether students wrote about utility value for themselves or received different forms of directly-communicated information about the utility value of a novel mental math technique. In Study 1, we examined the difference between directly-communicated and self-generated utility-value information and found that directly-communicated utility-value information undermined performance and interest for individuals who lacked confidence, but that self-generated utility had positive effects. However, Study 2 suggests that these negative effects of directly-communicated utility value can be ameliorated when participants are also given the chance to generate their own examples of utility value, revealing a synergistic effect of directly-communicated and self-generated utility value. In Study 3, we found that individuals who lacked confidence benefited more when everyday examples of utility value were communicated, rather than career and school examples.
Eng, Lars; Garcia, Brandon L; Geisbrecht, Brian V; Hanning, Anders
2018-02-26
Surface plasmon resonance (SPR) is a well-established method for biomolecular interaction studies. SPR monitors the binding of molecules to a solid surface, embodied as refractive index changes close to the surface. One limitation of conventional SPR is the universal nature of the detection that results in an inability to qualitatively discriminate between different binding species. Furthermore, it is impossible to directly discriminate two species simultaneously binding to different sites on a protein, which limits the utility of SPR, for example, in the study of allosteric binders or bi-specific molecules. It is also impossible in principle to discriminate protein conformation changes from actual binding events. Here we demonstrate how Label-Enhanced SPR can be utilized to discriminate and quantitatively monitor the simultaneous binding of two different species - one dye-labeled and one unlabeled - on a standard, single-wavelength SPR instrument. This new technique increases the versatility of SPR technology by opening up application areas where the usefulness of the approach has previously been limited. Copyright © 2018 Elsevier Inc. All rights reserved.
Survey of beam instrumentation used in SLC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ecklund, S.D.
A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs.
Safety parameters for avoiding acute ocular damage from the reflected CO2 (10.6 microns) laser beam.
Friedman, N R; Saleeby, E R; Rubin, M G; Sandu, T; Krull, E A
1987-11-01
Reflections from instruments in the surgical field involving the CO2 laser beam present a serious ocular hazard. In addition to the use of plastic or glass protective eyewear, this hazard can be minimized by utilizing anodized instruments and recognizing the specific distances at which various reflections are no longer hazardous depending upon certain variables, including laser output wattage, emergent beam lengths, and surface characteristics of the reflecting instruments.
Vestibular Function Measurement Devices
Miles, Richard D.; Zapala, David A.
2015-01-01
Vestibular function laboratories utilize a multitude of diagnostic instruments to evaluate a dizzy patient. Caloric irrigators, oculomotor stimuli, and rotational chairs produce a stimulus whose accuracy is required for the patient response to be accurate. Careful attention to everything from cleanliness of equipment to threshold adjustments determine on a daily basis if patient data are going to be correct and useful. Instrumentation specifications that change with time such as speed and temperature must periodically be checked using calibrated instruments. PMID:27516710
Sembrano, Jonathan N; Santos, Edward Rainier G; Polly, David W
2014-02-01
The O-arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA), an intraoperative CT scan imaging system, may provide high-quality imaging information to the surgeon. To our knowledge, its impact on spine surgery has not been studied. We reviewed 100 consecutive spine surgical procedures which utilized the new generation mobile intraoperative CT imaging system (O-arm). The most common diagnoses were degenerative conditions (disk disease, spondylolisthesis, stenosis and acquired kyphosis), seen in 49 patients. The most common indication for imaging was spinal instrumentation in 81 patients (74 utilized pedicle screws). In 52 (70%) of these, the O-arm was used to assess screw position after placement; in 22 (30%), it was coupled with Stealth navigation (Medtronic Sofamor Danek, Inc.) to guide screw placement. Another indication was to assess adequacy of spinal decompression in 38 patients; in 19 (50%) of these, intrathecal contrast material was used to obtain an intraoperative CT myelogram. In 20 patients O-arm findings led to direct surgeon intervention in the form of screw removal/repositioning (n=13), further decompression (n=6), interbody spacer repositioning (n=1), and removal of kyphoplasty trocar (n=1). In 20% of spine surgeries, the procedure was changed based on O-arm imaging findings. We found the O-arm to be useful for assessment of instrumentation position, adequacy of spinal decompression, and confirmation of balloon containment and cement filling in kyphoplasty. When used with navigation for image-guided surgery, it obviated the need for registration. Published by Elsevier Ltd.
Schiltz, Nicholas K; Warner, David F; Sun, Jiayang; Bakaki, Paul M; Dor, Avi; Given, Charles W; Stange, Kurt C; Koroukian, Siran M
2017-03-01
Multimorbidity affects the majority of elderly adults and is associated with higher health costs and utilization, but how specific patterns of morbidity influence resource use is less understood. The objective was to identify specific combinations of chronic conditions, functional limitations, and geriatric syndromes associated with direct medical costs and inpatient utilization. Retrospective cohort study using the Health and Retirement Study (2008-2010) linked to Medicare claims. Analysis used machine-learning techniques: classification and regression trees and random forest. A population-based sample of 5771 Medicare-enrolled adults aged 65 and older in the United States. Main covariates: self-reported chronic conditions (measured as none, mild, or severe), geriatric syndromes, and functional limitations. Secondary covariates: demographic, social, economic, behavioral, and health status measures. Medicare expenditures in the top quartile and inpatient utilization. Median annual expenditures were $4354, and 41% were hospitalized within 2 years. The tree model shows some notable combinations: 64% of those with self-rated poor health plus activities of daily living and instrumental activities of daily living disabilities had expenditures in the top quartile. Inpatient utilization was highest (70%) in those aged 77-83 with mild to severe heart disease plus mild to severe diabetes. Functional limitations were more important than many chronic diseases in explaining resource use. The multimorbid population is heterogeneous and there is considerable variation in how specific combinations of morbidity influence resource use. Modeling the conjoint effects of chronic conditions, functional limitations, and geriatric syndromes can advance understanding of groups at greatest risk and inform targeted tailored interventions aimed at cost containment.
Manns, David C; Mansfield, Anna Katharine
2012-08-17
Four high-throughput reverse-phase chromatographic protocols utilizing two different core-shell column chemistries have been developed to analyze the phenolic profiles of complex matrices, specifically targeting juices and wines produced from interspecific hybrid grape cultivars. Following pre-fractionation via solid-phase extraction or direct injection, individual protocols were designed to resolve, identify and quantify specific chemical classes of compounds including non-anthocyanin monomeric phenolics, condensed tannins following acid hydrolysis, and anthocyanins. Detection levels ranging from 1.2 ppb to 27.5 ppb, analyte %RSDs ranging from 0.04 to 0.38, and linear ranges of quantitation approaching five orders of magnitude were achieved using conventional HPLC instrumentation. Using C(18) column chemistry, the non-anthocyanin monomeric protocol effectively separated a set of 16 relevant phenolic compounds comprised flavan-3-ols, hydroxycinnamic acids, and flavonols in under 14 min. The same column was used to develop a 15-min protocol for hydrolyzed condensed tannin analysis. Two anthocyanin protocols are presented, one utilizing the same C(18) column, best suited for anthocyanidin and monoglucoside analysis, the other utilizing a pentafluorophenyl chemistry optimized to effectively separate complex mixtures of coexisting mono- and diglucoside anthocyanins. These protocols and column chemistries have been used initially to explore a wide variety of complex phenolic matrices, including red and white juices and wines produced from Vitis vinifera and interspecific hybrid grape cultivars, juices, teas, and plant extracts. Each protocol displayed robust matrix responses as written, yet are flexible enough to be easily modified to suit specifically tailored analytical requirements. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sargent, M. R.; Smith, J. B.; Wilmouth, D. M.; Sayres, D. S.; Anderson, J. G.
2013-12-01
Water vapor in the upper troposphere and lower stratosphere is central to both atmospheric chemistry and climate. Stratospheric water vapor concentrations influence surface dosages of UV radiation through the production of OH and by controlling the rates of heterogeneous reactions, both of which contribute to the catalytic destruction of ozone [e.g., Anderson et al., 2012]. Water vapor also impacts the radiative properties of the upper troposphere and lower stratosphere (UT/LS) directly and via the formation of thin cirrus, with the ability to significantly alter surface warming [Solomon et al., 2010]. However, with the documented disagreement among water vapor measurements on the order of 1 to 2 ppmv in the UT/LS, the atmospheric chemistry and climate community cannot reliably model the chemical and radiative properties of this region, predict the response of this region to anthropogenic climate forcing, or confidently detect trends in water vapor concentrations, particularly at the level of ~1%/year. In response to these concerns, the Harvard Water Vapor (HWV) instrument, designed for in situ measurement aboard NASA's high-altitude WB-57 and ER-2 aircraft, has been reconfigured to include two independent measurement methods for the simultaneous detection of ambient water vapor mixing ratios within a common duct. The dual-axis instrument combines the heritage of the Harvard Lyman-α photo-fragment fluorescence instrument (Ly-α) with the newly designed tunable diode laser direct absorption instrument, the Harvard Herriott Hygrometer (HHH). The utilization of two radically different measurement techniques facilitates the identification, diagnosis, and constraint of systematic errors in both the laboratory and flight environments. Here we present comparison data from two recent field campaigns which offered unprecedented opportunities for comparison and the assessment of instrumental accuracy in both the laboratory and in situ environments, 1) The Aqua Validation and Instrument Tests (AquaVIT-2), during April 2013 at the Aerosols Interaction and Dynamics in the Atmosphere (AIDA) chamber in Karlsruhe, Germany, and 2) NASA's Studies of Emissions, Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) mission, operated out of Houston, TX, in August and September of 2013. The Aquavit-2 campaign provided an excellent opportunity to evaluate both axes of the HWV instrument under a controlled laboratory setting, and to compare with other state-of-the-art hygrometers within the international community, many of which have contributed substantially to UT/LS water vapor measurements for several decades. Laboratory efforts, however, are limited by their ability to replicate the unique sampling conditions, e.g., temperature, pressure, flow, chemistry, of the flight environment. Differences in instrument implementation between the laboratory and flight environment must also be considered. The SEAC4RS mission provides an excellent opportunity to further evaluate the performance of the dual-axis instrument in situ. Sampling with the Ly-α and HHH instruments on the ER-2 in the proximity of Microwave Limb Sounder (MLS) overpasses and coordinated launches of the Cryogenic Frostpoint Hygrometer (CFH) promises a statistically significant and rich dataset for comparison.
The Use of Self-Regulated Learning Measure Questionnaires as a Predictor of Academic Success
ERIC Educational Resources Information Center
Bruso, Jackie L.; Stefaniak, Jill E.
2016-01-01
This study examined the potential of utilizing the Motivated Strategies for Learning Questionnaire (MSLQ) and the Online Strategies for Learning Questionnaire (OSLQ) as instruments in predicting academic success as measured by overall grade point average (GPA). These instruments were of particular interest because the MSLQ was designed to measure…
Labun, Evelyn; Yurkovich, Eleanor; Ide, Bette A.
2015-01-01
Deinstitutionalization of psychiatric mental health hospitals began in the 1960’s; thus, the delivery of mental health services became dependent on regional centers and community based, contracted services. One such service model is the psych-social club. Such clubs provide mental health services on the lower end of the cost continuum and reduce the utilization of higher cost services (Yurkovich, Labun, Cook & Lattergrass, 2005). This paper fills a gap by reporting on the development of a mixed method instrument entitled Benefits & Satisfaction Tool for Members of a Psych-social Club (B&ST-MPC). It also reports on the psychometric properties of the instrument, and measures members’ perception of satisfaction with and benefits of their psych-social club utilization, thus providing evaluative information for developing client centered continuums of care (Yurkovich et al., 2005). The paper includes a brief overview of the first mixed method study, background information on the rationale for instrument development, including methods used, and a discussion of the instrument’s psychometric properties. PMID:23164402
Plant canopy gap-size analysis theory for improving optical measurements of leaf-area index
NASA Astrophysics Data System (ADS)
Chen, Jing M.; Cihlar, Josef
1995-09-01
Optical instruments currently available for measuring the leaf-area index (LAI) of a plant canopy all utilize only the canopy gap-fraction information. These instruments include the Li-Cor LAI-2000 Plant Canopy Analyzer, Decagon, and Demon. The advantages of utilizing both the canopy gap-fraction and gap-size information are shown. For the purpose of measuring the canopy gap size, a prototype sunfleck-LAI instrument named Tracing Radiation and Architecture of Canopies (TRAC), has been developed and tested in two pure conifer plantations, red pine (Pinus resinosa Ait.) and jack pine (Pinus banksiana Lamb). A new gap-size-analysis theory is presented to quantify the effect of canopy architecture on optical measurements of LAI based on the gap-fraction principle. The theory is an improvement on that of Lang and Xiang [Agric. For. Meteorol. 37, 229 (1986)]. In principle, this theory can be used for any heterogeneous canopies.
Perroca, Marcia Galan; Ek, Anna-Christina
2007-07-01
Although patient classification tools have been used in Sweden since the 1980s, few studies have examined how they are utilized and monitored. This paper investigates the patient classification systems implemented in hospitals in the country as well as the level of satisfaction of nurses with the implemented instrument. A postal survey method was used in which a total of 128 questionnaires were sent to nurse managers. Twenty-three hospitals were identified with patient classification systems currently in operation. The Zebra and Beakta systems are the most commonly used instruments. Nurse managers appear to be satisfied with the patient classification systems in use on their wards as a whole except for their inability to measure the quality of care provided, the time spent to use the instruments and the fact that the administration do not estimate nursing staff requirements using the system.
Solid state instrumentation concepts for earth resource observation
NASA Technical Reports Server (NTRS)
Richard, H. L.
1982-01-01
Late in 1980, specifications were prepared for detail design definition of a six band solid state multispectral instrument having three visible (VIS), one near infrared (NIR), and two short wave infrared (SWIR) bands. This instrument concept, known as the Multispectral Linear Array (MLA), also offered increased spatial resolution, on board gain and offset correction, and additional operational modes which would allow for cross track and stereoscopic viewing as well as a multialtitude operational capability. A description is presented of a summary of some of the salient features of four different MLA design concepts, as developed by four American companies. The designs ranged from the use of multiple refractive telescopes utilizing three groups of focal plane detectors electronic correlation processing for achieving spatial registration, and incorporating palladium silicide (PdSi) SWIR detectors, to a four-mirror all-reflective telecentric system utilizing a beam splitter for spatial registration.
Thermal Behavior of Aerospace Spur Gears in Normal and Loss-of-Lubrication Conditions
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.
2015-01-01
Testing of instrumented spur gears operating at aerospace rotorcraft conditions was conducted. The instrumented gears were operated in a normal and in a loss-of-lubrication environment. Thermocouples were utilized to measure the temperature at various locations on the test gears and a test utilized a full-field, high-speed infrared thermal imaging system. Data from thermocouples was recorded during all testing at 1 hertz. One test had the gears shrouded and a second test was run without the shrouds to permit the infrared thermal imaging system to take data during loss-of-lubrication operation. Both tests using instrumented spur gears were run in normal and loss-of-lubrication conditions. Also the result from four other loss-of-lubrication tests will be presented. In these tests two different torque levels were used while operating at the same rotational speed (10000 revolutions per minute).
Thermal Behavior of Aerospace Spur Gears in Normal and Loss-of-Lubrication Conditions
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.
2015-01-01
Testing of instrumented spur gears operating at aerospace rotorcraft conditions was conducted. The instrumented gears were operated in a normal and in a loss-of-lubrication environment. Thermocouples were utilized to measure the temperature at various locations on the test gears and a test utilized a full-field, high-speed infrared thermal imaging system. Data from thermocouples was recorded during all testing at 1 Hz. One test had the gears shrouded and a second test was run without the shrouds to permit the infrared thermal imaging system to take date during loss-of-lubrication operation. Both tests using instrumented spur gears were run in normal and loss-of-lubrication conditions. Also the result from four other loss-of-lubrication tests will be presented. In these tests two different torque levels were used while operating at the same rotational speed (10000 rpm).
14 CFR 121.325 - Instruments and equipment for operations under IFR or over-the-top.
Code of Federal Regulations, 2011 CFR
2011-01-01
... preventing malfunctioning due to icing. (b) A sensitive altimeter. (c) Instrument lights providing enough light to make each required instrument, switch, or similar instrument, easily readable and so installed that the direct rays are shielded from the flight crewmembers' eyes and that no objectionable...
14 CFR 121.325 - Instruments and equipment for operations under IFR or over-the-top.
Code of Federal Regulations, 2014 CFR
2014-01-01
... preventing malfunctioning due to icing. (b) A sensitive altimeter. (c) Instrument lights providing enough light to make each required instrument, switch, or similar instrument, easily readable and so installed that the direct rays are shielded from the flight crewmembers' eyes and that no objectionable...
14 CFR 121.325 - Instruments and equipment for operations under IFR or over-the-top.
Code of Federal Regulations, 2010 CFR
2010-01-01
... preventing malfunctioning due to icing. (b) A sensitive altimeter. (c) Instrument lights providing enough light to make each required instrument, switch, or similar instrument, easily readable and so installed that the direct rays are shielded from the flight crewmembers' eyes and that no objectionable...
14 CFR 121.325 - Instruments and equipment for operations under IFR or over-the-top.
Code of Federal Regulations, 2013 CFR
2013-01-01
... preventing malfunctioning due to icing. (b) A sensitive altimeter. (c) Instrument lights providing enough light to make each required instrument, switch, or similar instrument, easily readable and so installed that the direct rays are shielded from the flight crewmembers' eyes and that no objectionable...
14 CFR 121.325 - Instruments and equipment for operations under IFR or over-the-top.
Code of Federal Regulations, 2012 CFR
2012-01-01
... preventing malfunctioning due to icing. (b) A sensitive altimeter. (c) Instrument lights providing enough light to make each required instrument, switch, or similar instrument, easily readable and so installed that the direct rays are shielded from the flight crewmembers' eyes and that no objectionable...
Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-01-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348
Tejwani, Rohit; Wang, Hsin-Hsiao S; Lloyd, Jessica C; Kokorowski, Paul J; Nelson, Caleb P; Routh, Jonathan C
2017-03-01
The advent of online task distribution has opened a new avenue for efficiently gathering community perspectives needed for utility estimation. Methodological consensus for estimating pediatric utilities is lacking, with disagreement over whom to sample, what perspective to use (patient vs parent) and whether instrument induced anchoring bias is significant. We evaluated what methodological factors potentially impact utility estimates for vesicoureteral reflux. Cross-sectional surveys using a time trade-off instrument were conducted via the Amazon Mechanical Turk® (https://www.mturk.com) online interface. Respondents were randomized to answer questions from child, parent or dyad perspectives on the utility of a vesicoureteral reflux health state and 1 of 3 "warm-up" scenarios (paralysis, common cold, none) before a vesicoureteral reflux scenario. Utility estimates and potential predictors were fitted to a generalized linear model to determine what factors most impacted utilities. A total of 1,627 responses were obtained. Mean respondent age was 34.9 years. Of the respondents 48% were female, 38% were married and 44% had children. Utility values were uninfluenced by child/personal vesicoureteral reflux/urinary tract infection history, income or race. Utilities were affected by perspective and were higher in the child group (34% lower in parent vs child, p <0.001, and 13% lower in dyad vs child, p <0.001). Vesicoureteral reflux utility was not significantly affected by the presence or type of time trade-off warm-up scenario (p = 0.17). Time trade-off perspective affects utilities when estimated via an online interface. However, utilities are unaffected by the presence, type or absence of warm-up scenarios. These findings could have significant methodological implications for future utility elicitations regarding other pediatric conditions. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
A Self-Report Measure of Physical Activity
ERIC Educational Resources Information Center
Siegel, Donald
2005-01-01
There are multiple approaches to measuring physical activity. Among these are direct observation, electronic monitoring, direct and indirect calorimetry, and self-report instruments. Self-report instruments are the most practical and cost effective option for use with a large group. In a study by Motl, Dishman, Dowda, and Pate (2004), two groups…
Surface and borehole neutron probes for the Construction and Resource Utilization eXplorer (CRUX)
NASA Technical Reports Server (NTRS)
Elphic, Richard C.; Hahn, Sangkoo; Lawrence, David J.; Feldman, William C.; Johnson, Jerome B.; Haldemann, Albert F. C.
2006-01-01
The Construction and Resource Utilization eXplorer (CRUX) project aims to develop an integrated, flexible suite of instruments with data fusion software and an executive controller for the purpose of in situ resource assessment and characterization for future space exploration.
Mass Spectrometry for Planetary Probes: Past, Present and Future
NASA Technical Reports Server (NTRS)
Niemann, Hasso B.; Harpold, Dan N.; Jamieson, Brian G.; Mahaffy, Paul R.
2005-01-01
Atmospheric entry probes present a unique opportunity for performing quantitative analysis of extra-terrestrial atmospheres in cases where remote sensing alone may not be sufficient and measurements with balloons or aircraft is not practical. An entry probe can provide a complete vertical profile of atmospheric parameters including chemical composition, which cannot be obtained with most other techniques. There are, however, unique challenges associated with building instruments for an entry probe, as compared to orbiters, landers, or rovers. Conditions during atmospheric entry are extreme, there are inherent time constraints due to the short duration of the experiment, and the instrument experiences rapid environmental changes in temperature and pressure as it descends. In addition, there are resource limitations, i.e. mass, power, size and bandwidth. Finally, the demands on the instrument design are determined in large part by conditions (pressure, temperature, composition) unique to the particular body under study, and as a result there is no one-size-fits-all instrument for an atmospheric probe. Many of these requirements can be more easily met by miniaturizing the probe instrument. Our experience building mass spectrometers for atmospheric entry probes leads us to believe that the time is right for a fundamental change in the way spaceflight mass spectrometers are built. The emergence over the past twenty years of Micro-electro- mechanical Systems (MEMS), utilizing lithographic semiconductor fabrication techniques to produce instrument systems in miniature, holds great promise for application to spaceflight mass spectrometry. A highly miniaturized, high performance and low-power mass spectrometer would be an enormous benefit to future entry probe missions, allowing, for example, parallel measurements (e.g., multiple simultaneous gas chromatographic analyses and direct atmospheric leaks.) Such an instrument would also enable mass spectrometry on board small multiple entry probes. In the development of a MEMS Mass Spectrometer, the challenge facing us is to move beyond the proof-of-concept, where research dollars tend to focus, and carry out the detailed work of developing a high performance mass spectrometer system on a chip which meets the unique technical requirements for an atmospheric entry probe described above.
Coordinated Ground- and Space-based Multispectral Campaign to Study Equatorial Spread-F Formation
NASA Astrophysics Data System (ADS)
Finn, S. C.; Geddes, G.; Aryal, S.; Stephan, A. W.; Budzien, S. A.; Duggirala, P. R.; Chakrabarti, S.; Valladares, C.
2016-12-01
We present a concept for a multispectral campaign using coordinated data from state-of-the-art instruments aboard the International Space Station (ISS) and multiple ground-based spectrometers and digisondes deployed at low-latitudes to study the formation and development of Equatorial Spread-F (ESF). This extended observational campaign utilizes ultraviolet, visible, and radio measurements to develop a predictive capability for ESF and to study the coupling of the ionosphere-thermosphere (I-T) system during geomagnetically quiet and disturbed times. The ground-based instruments will be deployed in carefully chosen locations in the American and Indian sectors while the space-based data will provide global coverage spanning all local times and longitudes within ±51° geographic latitudes. The campaign, over an extended period covering a range of geophysical conditions, will provide the extensive data base necessary to address the important science questions. The space-based instrument suite consists of the Limb-imaging Ionospheric and Thermospheric Extreme-ultraviolet Spectrograph (LITES) and the GPS Radio Occultation and Ultraviolet Photometry-Colocated (GROUP-C) instruments, scheduled to launch to the ISS in November 2016. LITES is a compact imaging spectrograph for remote sensing of the upper atmosphere and ionosphere from 60 to 140nm and GROUP-C has a nadir-viewing FUV photometer. The ground-based instruments to be deployed for this campaign are three high-resolution imaging spectrographs capable of continuous round-the-clock airglow observations: Multiwavelength Imaging Spectrograph using Echelle grating (MISE) in India and two High Throughput and Multi-slit Imaging Spectrographs (HiT&MIS) to be deployed in Colombia and Argentina, the Low-Latitude Ionosphere Sensor Network (LISN), and the Global Ionospheric Radio Observatory (GIRO) digisondes network. We present data from the ground-based instruments, initial results from the LITES and GROUP-C instruments on-orbit, and modeling and analysis methods for the campaign. This work was supported by NSF 1315354 and 1145166, and ONR N00014-13-1-0266 grants. LITES and GROUP-C are part of the STP-H5 Payload, integrated and flown under the direction of the DoD Space Test Program.
Sources of Biased Inference in Alcohol and Drug Services Research: An Instrumental Variable Approach
Schmidt, Laura A.; Tam, Tammy W.; Larson, Mary Jo
2012-01-01
Objective: This study examined the potential for biased inference due to endogeneity when using standard approaches for modeling the utilization of alcohol and drug treatment. Method: Results from standard regression analysis were compared with those that controlled for endogeneity using instrumental variables estimation. Comparable models predicted the likelihood of receiving alcohol treatment based on the widely used Aday and Andersen medical care–seeking model. Data were from the National Epidemiologic Survey on Alcohol and Related Conditions and included a representative sample of adults in households and group quarters throughout the contiguous United States. Results: Findings suggested that standard approaches for modeling treatment utilization are prone to bias because of uncontrolled reverse causation and omitted variables. Compared with instrumental variables estimation, standard regression analyses produced downwardly biased estimates of the impact of alcohol problem severity on the likelihood of receiving care. Conclusions: Standard approaches for modeling service utilization are prone to underestimating the true effects of problem severity on service use. Biased inference could lead to inaccurate policy recommendations, for example, by suggesting that people with milder forms of substance use disorder are more likely to receive care than is actually the case. PMID:22152672
High-Speed Laser Scanner Maps a Surface in Three Dimensions
NASA Technical Reports Server (NTRS)
Lavelle, Joseph; Schuet, Stefan
2006-01-01
A scanning optoelectronic instrument generates the digital equivalent of a threedimensional (X,Y,Z) map of a surface that spans an area with resolution on the order of 0.005 in. ( 0.125mm). Originally intended for characterizing surface flaws (e.g., pits) on space-shuttle thermal-insulation tiles, the instrument could just as well be used for similar purposes in other settings in which there are requirements to inspect the surfaces of many objects. While many commercial instruments can perform this surface-inspection function, the present instrument offers a unique combination of capabilities not available in commercial instruments. This instrument utilizes a laser triangulation method that has been described previously in NASA Tech Briefs in connection with simpler related instruments used for different purposes. The instrument includes a sensor head comprising a monochrome electronic camera and two lasers. The camera is a high-resolution
The Austrian radiation monitoring network ARAD - best practice and added value
NASA Astrophysics Data System (ADS)
Olefs, Marc; Baumgartner, Dietmar J.; Obleitner, Friedrich; Bichler, Christoph; Foelsche, Ulrich; Pietsch, Helga; Rieder, Harald E.; Weihs, Philipp; Geyer, Florian; Haiden, Thomas; Schöner, Wolfgang
2016-04-01
The Austrian RADiation monitoring network (ARAD) has been established to advance the national climate monitoring and to support satellite retrieval, atmospheric modeling and the development of solar energy techniques. Measurements cover the downward solar and thermal infrared radiation using instruments according to Baseline Surface Radiation Network (BSRN) standards. A unique feature of ARAD is its vertical dimension of five stations, covering an altitude range between about 200 m a.s.l (Vienna) and 3100 m a.s.l. (BSRN site Sonnblick). The paper outlines the aims and scopes of ARAD, its measurement and calibration standards, methods, strategies and station locations. ARAD network operation uses innovative data processing for quality assurance and quality control, utilizing manual and automated control algorithms. A combined uncertainty estimate for the broadband shortwave radiation fluxes at all five ARAD stations, using the methodology specified by the Guide to the Expression of Uncertainty in Measurement indicates that relative accuracies range from 1.5 to 2.9 % for large signals (global, direct: 1000 W m-2, diffuse: 500 W m-2) and from 1.7 to 23 % (or 0.9 to 11.5 W m-2) for small signals (50 W m-2) (expanded uncertainties corresponding to the 95 % confidence level). If the directional response error of the pyranometers and the temperature response of the instruments and the data acquisition system (DAQ) are corrected, this expanded uncertainty reduces to 1.4 to 2.8 % for large signals and to 1.7 to 5.2 % (or 0.9-2.6 W m-2) for small signals. Thus, for large signals of global and diffuse radiation, BSRN target accuracies are met or nearly met (missed by less than 0.2 percentage points, pps) for 70 % of the ARAD measurements after this correction. For small signals of direct radiation, BSRN targets are achieved at two sites and nearly met (also missed by less than 0.2 pps) at the other sites. For small signals of global and diffuse radiation, targets are achieved at all stations. Additional accuracy gains can be achieved in the future through additional measurements, corrections and a further upgrade of the DAQ. However, to improve the accuracy of measurements of direct solar radiation, improved instrument accuracy is needed. ARAD could serve as a useful example for establishing state-of-the-art radiation monitoring at the national level with a multiple-purpose approach. Instrumentation, guidelines and tools (such as the data quality control) developed within ARAD are intended to increase monitoring capabilities of global radiation and thus designed to allow straightforward adoption in other regions, without high development costs.
NASA Technical Reports Server (NTRS)
Derrickson, J. H.; Wu, J.; Christl, M. J.; Fountain, W. F.; Parnell, T. A.
1999-01-01
The "all-particle" cosmic ray energy spectrum appears to be exhibiting a significant change in the spectral index just above approximately 3000 TeV. This could indicate (1) a change in the propagation of the cosmic rays in the galactic medium, and/or (2) the upper limit of the supernova shock wave acceleration mechanism, and/or (3) a new source of high-energy cosmic rays. Air shower and JACEE data indicate the spectral change is associated with a composition change to a heavier element mixture whereas DICE does not indicate this. A detector concept will be presented that utilizes the energy dependence of the production of direct Coulomb electron-positron pairs by energetic heavy ions. Monte Carlo simulations of a direct electron pair detector consisting of Pb target foils interleaved with planes of 1-mm square scintillating optical fibers will be discussed. The goal is to design a large area, non-saturating instrument to measure the energy spectrum of the individual cosmic ray elements in the "VH-group" for energies greater than 10 TeV/nucleon.
NASA Astrophysics Data System (ADS)
Howe, Glenn A.; Mendillo, Christopher B.; Hewawasam, Kuravi; Martel, Jason; Finn, Susanna C.; Cook, Timothy A.; Chakrabarti, Supriya
2017-09-01
The Planetary Imaging Concept Testbed Using a Recoverable Experiment - Coronagraph (PICTURE-C) mission will directly image debris disks and exozodiacal dust around three nearby stars from a high-altitude balloon using a vector vortex coronagraph. We present experimental results of the PICTURE-C low-order wavefront control (LOWFC) system utilizing a Shack-Hartmann (SH) sensor in an instrument testbed. The SH sensor drives both the alignment of the telescope secondary mirror using a 6-axis Hexapod and a surface parallel array deformable mirror to remove residual low-order aberrations. The sensor design and actuator calibration methods are discussed and the preliminary LOWFC closed-loop performance is shown to stabilize a reference wavefront to an RMS error of 0.30 +/- 0.29 nm.
Nondestructive detection and measurement of hydrogen embrittlement
Alex, Franklin; Byrne, Joseph Gerald
1977-01-01
A nondestructive system and method for the determination of the presence and extent of hydrogen embrittlement in metals, alloys, and other crystalline structures subject thereto. Positron annihilation characteristics of the positron-electron annihilation within the tested material provide unique energy distribution curves for each type of material tested at each respective stage of hydrogen embrittlement. Gamma radiation resulting from such annihilation events is detected and statistically summarized by appropriate instrumentation to reveal the variations of electron activity within the tested material caused by hydrogen embrittlement therein. Such data from controlled tests provides a direct indication of the relative stages of hydrogen embrittlement in the form of unique energy distribution curves which may be utilized as calibration curves for future comparison with field tests to give on-site indication of progressive stages of hydrogen embrittlement.
Yates, John R
2015-11-01
Advances in computer technology and software have driven developments in mass spectrometry over the last 50 years. Computers and software have been impactful in three areas: the automation of difficult calculations to aid interpretation, the collection of data and control of instruments, and data interpretation. As the power of computers has grown, so too has the utility and impact on mass spectrometers and their capabilities. This has been particularly evident in the use of tandem mass spectrometry data to search protein and nucleotide sequence databases to identify peptide and protein sequences. This capability has driven the development of many new approaches to study biological systems, including the use of "bottom-up shotgun proteomics" to directly analyze protein mixtures. Graphical Abstract ᅟ.
Canning, Elizabeth A.; Harackiewicz, Judith M.
2015-01-01
Social-psychological interventions in education have used a variety of “self-persuasion” or “saying-is-believing” techniques to encourage students to articulate key intervention messages. These techniques are used in combination with more overt strategies, such as the direct communication of messages in order to promote attitude change. However, these different strategies have rarely been systematically compared, particularly in controlled laboratory settings. We focus on one intervention based in expectancy-value theory designed to promote perceptions of utility value in the classroom and test different intervention techniques to promote interest and performance. Across three laboratory studies, we used a mental math learning paradigm in which we varied whether students wrote about utility value for themselves or received different forms of directly-communicated information about the utility value of a novel mental math technique. In Study 1, we examined the difference between directly-communicated and self-generated utility-value information and found that directly-communicated utility-value information undermined performance and interest for individuals who lacked confidence, but that self-generated utility had positive effects. However, Study 2 suggests that these negative effects of directly-communicated utility value can be ameliorated when participants are also given the chance to generate their own examples of utility value, revealing a synergistic effect of directly-communicated and self-generated utility value. In Study 3, we found that individuals who lacked confidence benefited more when everyday examples of utility value were communicated, rather than career and school examples. PMID:26495326
A 2 THz Heterodyne Array Receiver for SOFIA
NASA Technical Reports Server (NTRS)
Walker, Christopher K.
1998-01-01
We proposed to perform a comprehensive design study of a 16-element heterodyne array receiver for SOFIA. The array was designed to utilize hot-electron bolometers in an efficient, low-cost waveguide mount to achieve low noise performance between approx. 1500 and 2400 GHz. Due to the prevailing physical conditions in the interstellar medium, this frequency range is one of the richest in the FIR portion of the spectrum. An array designed for this wavelength range will make excellent use of the telescope and the available atmospheric transmission, and will provide a new perspective on stellar, chemical, and galaxy evolution in the present as well as past epochs. A few of the most important molecular and atomic species which the instrument will sample are CII, OI, CO, OH, NII, and CH. The system used the most sensitive detectors available in an efficient optical system. The local oscillator was a compact CO2 pumped far-infrared laser currently under development for SOFIA. The backend spectrometer was an array acousto-optic spectrometer (aAOS). The spectrometer utilizes proven hardware and technologies to provide broadband performance (greater than or equal to 1 GHz per AOS channel) and high spectral resolution (1 MHz) with the maximum sensitivity and minimum complexity and cost. The proposed instrument would be the fastest and most sensitive heterodyne receiver ever to operate in the 1.5 - 2.4 THz band. One of the key technologies developed for the proposed instrument is the laser micromachining of waveguide structures. These structures provide both the optical link between the instrument and the telescope (via an array of efficient feedhorns) and the impedance transformation between the detectors and free space. With the assistance of funds provided from this grant, we were able to fabricate and test the world's first laser micromachined feedhorns. Figure 1 is a photograph of the 2 THz double feedhorn structure designed and constructed under the auspices of this grant. The quality of the waveguide structure is far better than that obtainable using any other fabrication technique. Figure 2 is the beam pattern obtained from it. The beam parameters are an excellent match to what is expected from theory. The success of this experiment demonstrates the viability of using laser micromachined components in the development of high performance, large format array receivers. Figure 3 is an illustration of the focal plane array concept we developed lot- SOFIA base upon this work. Un- fortunately, our instrument proposal was not selected as a first generation SOFIA instrument. However, we have continued our development efforts and will propose to build a 2nd generation instrument based on the same design concepts. Our work under NAG 2-1057 was very rewarding and we appreciate the opportunity provided by NASA to pursue it. The research led directly to publishing 2 papers (listed below) and the award of an NSF grant to our group to construct a laser micromachining system on the University of Arizona campus.
ERIC Educational Resources Information Center
Pursell, Christopher J.; Chandler, Bert; Bushey, Michelle M.
2004-01-01
Capillary electrophoresis is gradually working its way into the undergraduate laboratory curriculum. Typically, experiments utilizing this newer technology have been introduced into analytical or instrumental courses. The authors of this article have introduced an experiment into the introductory laboratory that utilizes capillary electrophoresis…
Low power data acquisition unit for autonomous geophysical instrumentation
NASA Astrophysics Data System (ADS)
Prystai, Andrii
2017-04-01
The development of an autonomous instrumentation for field research is always a challenge which needs knowledge and application of recent advances in technology and components production. Using this information a super-low power, low-cost, stand-alone GPS time synchronized data acquisition unit was created. It comprises an extended utilization of the microcontroller modules and peripherals and special firmware with flexible PLL parameters. The present report is devoted to a discussion of synchronization mode of data sampling in autonomous field instruments with possibility of GPS random breaks. In the result the achieved sampling timing accuracy is better than ± 60 ns without phase jumps and distortion plus fixed shift depending on the sample rate. The main application of the system is for simultaneous measurement of several channels from magnetic and electric sensors in field conditions for magneto-telluric instruments. First utilization of this system was in the new developed versions of LEMI-026 magnetometer and LEMI-423 field station, where it was applied for digitizing of up to 6 analogue channels with 32-bit resolution in the range ± 2.5V, digital filtration (LPF) and maximum sample rate 4kS/s. It is ready for record in 5 minutes after being turned on. Recently, this system was successfully utilized with the drone-portable magnetometers destined for the search of metallic objects, like UXO, in rural areas, research of engineering underground structure and for mapping ore bodies. The successful tests of drone-portable system were made and tests results are also discussed.
Amador Fierros, Genoveva; Montesinos-López, Osval Antonio; Alcaráz Moreno, Noemí
2016-04-01
This work sought to validate and propose an instrument to measure the performance of tutors in promoting self-directed learning in students involved in processes of problem-based learning. Confirmatory factor analysis (CFA) was applied to validate the instrument composed of 60 items and six factors (self-assessment of learning gaps within the United Nations specific context: self-assessment, reflexion, critical thinking, administration of information, group skills), using a sample of 207 students from a total of 279, which comprise the student population of the Faculty of Nursing at Universidad de Colima in Mexico. (2007). The CFA results demonstrated that the instrument is acceptable to measure performance of tutors in promoting self-directed learning, given that all the indicators, variances, covariances, and thresholds are statistically significant. The instrument permits obtaining students' opinions on how much professors contribute for them to develop each of the 60 skills described in the scale. Lastly, the results could report if professors are placing more emphasis in some areas than in other areas they should address during the problem-based learning (PBL) process, or if definitely their actions are removed from the premises of PBL, information that will be useful for school management in decision making on the direction of teaching as a whole.
Measuring Resource Utilization: A Systematic Review of Validated Self-Reported Questionnaires.
Leggett, Laura E; Khadaroo, Rachel G; Holroyd-Leduc, Jayna; Lorenzetti, Diane L; Hanson, Heather; Wagg, Adrian; Padwal, Raj; Clement, Fiona
2016-03-01
A variety of methods may be used to obtain costing data. Although administrative data are most commonly used, the data available in these datasets are often limited. An alternative method of obtaining costing is through self-reported questionnaires. Currently, there are no systematic reviews that summarize self-reported resource utilization instruments from the published literature.The aim of the study was to identify validated self-report healthcare resource use instruments and to map their attributes.A systematic review was conducted. The search identified articles using terms like "healthcare utilization" and "questionnaire." All abstracts and full texts were considered in duplicate. For inclusion, studies had to assess the validity of a self-reported resource use questionnaire, to report original data, include adult populations, and the questionnaire had to be publically available. Data such as type of resource utilization assessed by each questionnaire, and validation findings were extracted from each study.In all, 2343 unique citations were retrieved; 2297 were excluded during abstract review. Forty-six studies were reviewed in full text, and 15 studies were included in this systematic review. Six assessed resource utilization of patients with chronic conditions; 5 assessed mental health service utilization; 3 assessed resource utilization by a general population; and 1 assessed utilization in older populations. The most frequently measured resources included visits to general practitioners and inpatient stays; nonmedical resources were least frequently measured. Self-reported questionnaires on resource utilization had good agreement with administrative data, although, visits to general practitioners, outpatient days, and nurse visits had poorer agreement.Self-reported questionnaires are a valid method of collecting data on healthcare resource utilization.
A review of health-related workplace productivity loss instruments.
Lofland, Jennifer H; Pizzi, Laura; Frick, Kevin D
2004-01-01
The objective of this review was to identify health-related workplace productivity loss survey instruments, with particular emphasis on those that capture a metric suitable for direct translation into a monetary figure. A literature search using Medline, HealthSTAR, PsycINFO and Econlit databases between 1966 and 2002, and a telephone-administered survey of business leaders and researchers, were conducted to identify health-related workplace productivity measurement survey instruments. This review was conducted from the societal perspective. Each identified instrument was reviewed for the following: (i). reliability; (ii). content validity; (iii). construct validity; (iv). criterion validity; (v). productivity metric(s); (vi). instrument scoring technique; (vii). suitability for direct translation into a monetary figure; (viii). number of items; (ix). mode(s) of administration; and (x). disease state(s) in which it had been tested. Reliability and validity testing have been performed for 8 of the 11 identified surveys. Of the 11 instruments identified, six captured metrics that are suitable for direct translation into a monetary figure. Of those six, one instrument measured absenteeism, while the other five measured both absenteeism and presenteeism. All of the identified instruments except for one were available as paper, self-administered questionnaires and many were available in languages other than English. This review provides a comprehensive overview of the published, peer-reviewed survey instruments available to measure health-related workplace productivity loss. As the field of productivity measurement matures, tools may be developed that will allow researchers to accurately calculate lost productivity costs when performing cost-effectiveness and cost-benefit analyses. Using data captured by these instruments, society and healthcare decision makers will be able to make better informed decisions concerning the value of the medications, disease management and health promotion programmes that individuals receive.
Defense Infrastructure: Actions Needed to Strengthen Utility Resilience Planning
2016-11-01
and design , historical architecture and materials, and overhead; and inflation adjustments. 6We obtained and analyzed records from DOD’s Real...the impacts of those disruptions, and the characteristics of the DOD-owned utility systems, among other things. To inform the design of our survey...managing and operating DOD-owned utility systems. Furthermore, the survey instrument was independently reviewed by a survey design expert within GAO. We
Vertical Load Induced with Twisted File Adaptive System during Canal Shaping.
Jamleh, Ahmed; Alfouzan, Khalid
2016-12-01
To evaluate the vertical load induced with the Twisted File Adaptive (TFA; SybronEndo, Orange, CA) system during canal shaping of extracted teeth by comparing it with the Twisted File (TF, SybronEndo), ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), and ProTaper Universal (PTU, Dentsply Maillefer) systems. Fifty-two root canals were shaped using the TFA, TF, PTN, or PTU systems (n = 13 for each system). They were shaped gently according to the manufacturers' instructions. During canal shaping, vertical loads were recorded and shown in 2 directions, apically and coronally directed loads. The vertical peak loads of 3 instrumentation stages were used for comparison. The effects of rotary systems on the mean positive and negative peak loads were analyzed statistically using the Kruskal-Wallis and Mann-Whitney tests at a confidence level of 95%. The overall pattern of the instantaneous loads appeared to increase with the use of successive instruments within the system. During canal shaping in all groups, the apically and coronally directed peak loads ranged from 0.84-7.55 N and 2.16-2.79 N, respectively. There were significant differences in both peak loads among the tested systems at each instrumentation stage. TFA had the lowest apically directed peak loads. In terms of coronally directed peak loads, the TFA and TF had a significantly lower amount of loads developed with their instruments than PTN and PTU. The choice of instrument system had an influence on the loads developed during canal shaping. TFA instruments were associated favorably with the lowest values of peak loads followed by TF, PTN, and PTU. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Yan, Yuetian; Ubukata, Masaaki; Cody, Robert B.; Holy, Timothy E.; Gross, Michael L.
2014-01-01
A method for structural elucidation of biomolecules dating to the 1980s utilized high-energy collisions (~10 keV, laboratory frame) that induced charge-remote fragmentations (CRF), a class of fragmentations particularly informative for lipids, steroids, surfactants, and peptides. Unfortunately, the capability for high-energy activation has largely disappeared with the demise of magnetic sector instruments. With the latest designs of tandem time-of-flight mass spectrometers (TOF/TOF), however, this capability is now being restored to coincide with the renewed interest in metabolites and lipids including steroid-sulfates and other steroid metabolites. For these metabolites, structure determinations are required at concentration levels below that appropriate for NMR. To meet this need, we explored CRF with TOF/TOF mass spectrometry for two groups of steroid sulfates, 3-sulfates and 21-sulfates. We demonstrated that the current generation of MALDI TOF/TOF instruments can generate charge-remote-fragmentations for these materials. The resulting collision-induced dissociation (CID) spectra are useful for positional isomer differentiation and very often allow the complete structure determination of the steroid. We also propose a new nomenclature that directly indicates the cleavage sites on the steroid ring with carbon numbers. PMID:24781458
Yan, Yuetian; Ubukata, Masaaki; Cody, Robert B; Holy, Timothy E; Gross, Michael L
2014-08-01
A method for structural elucidation of biomolecules dating to the 1980s utilized high-energy collisions (~10 keV, laboratory frame) that induced charge-remote fragmentations (CRF), a class of fragmentations particularly informative for lipids, steroids, surfactants, and peptides. Unfortunately, the capability for high-energy activation has largely disappeared with the demise of magnetic sector instruments. With the latest designs of tandem time-of-flight mass spectrometers (TOF/TOF), however, this capability is now being restored to coincide with the renewed interest in metabolites and lipids, including steroid-sulfates and other steroid metabolites. For these metabolites, structure determinations are required at concentration levels below that appropriate for NMR. To meet this need, we explored CRF with TOF/TOF mass spectrometry for two groups of steroid sulfates, 3-sulfates and 21-sulfates. We demonstrated that the current generation of MALDI TOF/TOF instruments can generate charge-remote fragmentations for these materials. The resulting collision-induced dissociation (CID) spectra are useful for positional isomer differentiation and very often allow the complete structure determination of the steroid. We also propose a new nomenclature that directly indicates the cleavage sites on the steroid ring with carbon numbers.
The HOLO Series: Critical Ground-Based Demonstrations of Holographic Scanning Lidars
NASA Technical Reports Server (NTRS)
Wilkerson, Thomas D.; Sanders, Jason A.; Andrus, Ionio Q.; Schwemmer, Geary K.; Miller, David O.; Guerra, David; Schnick, Jeffrey; Moody, Stephen E.
2000-01-01
Results of two lidar measurement campaigns are presented, HOLO-1 (Utah, March 1999) and HOLO-2 (New Hampshire, June 1999). These tests demonstrate the ability of lidars utilizing holographic optical elements (HOEs) to determine tropospheric wind velocity and direction at cloud altitude. Several instruments were employed. HOLO-1 used the 1,064 mm transmission-HOE lidar (HARLIE, Goddard Space Flight Center), a zenith-staring 532 nm lidar (AROL-2, Utah State University), and a wide-field video camera (SkyCam) for imagery of clouds overhead. HOLO-2 included these instruments plus the 532 nm reflection-HOE lidar (PHASERS, St. Anselm College). HARLIE and PHASERS scan the sky at constant cone angles of 45 deg. and 42 deg. from normal, respectively. The progress of clouds and entire cloud fields across the sky is tracked by the repetitive conical scans of the HOE lidars. AROL-2 provides the attitude information enabling the SkyCam cloud images to be analyzed for independent data on cloud motion. Data from the HOE lidars are reduced by means of correlations, visualization by animation techniques, and kinematic diagrams of cloud feature motion. Excellent agreement is observed between the HOE lidar results and those obtained with video imagery and lidar ranging.
Radio Sounding Science at High Powers
NASA Technical Reports Server (NTRS)
Green, J. L.; Reinisch, B. W.; Song, P.; Fung, S. F.; Benson, R. F.; Taylor, W. W. L.; Cooper, J. F.; Garcia, L.; Markus, T.; Gallagher, D. L.
2004-01-01
Future space missions like the Jupiter Icy Moons Orbiter (JIMO) planned to orbit Callisto, Ganymede, and Europa can fully utilize a variable power radio sounder instrument. Radio sounding at 1 kHz to 10 MHz at medium power levels (10 W to kW) will provide long-range magnetospheric sounding (several Jovian radii) like those first pioneered by the radio plasma imager instrument on IMAGE at low power (less than l0 W) and much shorter distances (less than 5 R(sub E)). A radio sounder orbiting a Jovian icy moon would be able to globally measure time-variable electron densities in the moon ionosphere and the local magnetospheric environment. Near-spacecraft resonance and guided echoes respectively allow measurements of local field magnitude and local field line geometry, perturbed both by direct magnetospheric interactions and by induced components from subsurface oceans. JIMO would allow radio sounding transmissions at much higher powers (approx. 10 kW) making subsurface sounding of the Jovian icy moons possible at frequencies above the ionosphere peak plasma frequency. Subsurface variations in dielectric properties, can be probed for detection of dense and solid-liquid phase boundaries associated with oceans and related structures in overlying ice crusts.
Hallett, Kerrod B; O'Rourke, Peter K
2013-01-01
The purpose of this study was to evaluate a chairside caries risk assessment protocol utilizing a caries prediction instrument, adenosine triphosphate (ATP) activity in dental plaque, mutans streptococci (MS) culture, and routine dental examination in five- to 10-year-old children at two regional Australian schools with high caries experience. Clinical indicators for future caries were assessed at baseline examination using a standardized prediction instrument. Plaque ATP activity was measured directly in relative light units (RLU) using a bioluminescence meter, and MS culture data were recorded. Each child's dentition was examined clinically and radiographically, and caries experience was recorded using enamel white spot lesions and decayed, missing, and filled surfaces for primary and permanent teeth indices. Univariate one-way analysis of variance between selected clinical indicators, ATP activity, MS count at baseline, and future new caries activity was performed, and a generalized linear model for prediction of new caries activity at 24 months was constructed. Future new caries activity was significantly associated with the presence of visible cavitations, reduced saliva flow, and orthodontic appliances at baseline (R(2)=0.2, P<.001). Baseline plaque adenosine triphosphate activity and mutans streptococci counts were not significantly associated with caries activity at 24 months.
A photoelectric skylight polarimeter.
Hariharan, T A; Sekera, Z
1966-09-01
A photoelectric skylight polarimeter to measure directly the Stokes parameters for plane polarized light is described. The basic principle of the instrument consists in the simultaneous measurement of the intensity of light (in the chosen spectral region) transmitted by polarizers oriented in four specific directions. The main features and performance characteristics of the instrument are briefly discussed.
Interplanetary and Interstellar Dust Observed by the Wind/WAVES Electric Field Instrument
NASA Technical Reports Server (NTRS)
Malaspina, David; Horanyi, M.; Zaslavsky, A.; Goetz, K.; Wilson, L. B., III; Kersten, K.
2014-01-01
Observations of hypervelocity dust particles impacting the Wind spacecraft are reported here for the first time using data from the WindWAVES electric field instrument. A unique combination of rotating spacecraft, amplitude-triggered high-cadence waveform collection, and electric field antenna configuration allow the first direct determination of dust impact direction by any spacecraft using electric field data. Dust flux and impact direction data indicate that the observed dust is approximately micron-sized with both interplanetary and interstellar populations. Nanometer radius dust is not detected by Wind during times when nanometer dust is observed on the STEREO spacecraft and both spacecraft are in close proximity. Determined impact directions suggest that interplanetary dust detected by electric field instruments at 1 AU is dominated by particles on bound trajectories crossing Earths orbit, rather than dust with hyperbolic orbits.
Alphus D. Wilson
2012-01-01
The rapid development of new electronic technologies and instruments, utilized to perform many current clinical operations in the biomedical field, is changing the way medical health care is delivered to patients. The majority of test results from laboratory analyses, performed with these analytical instruments often prior to clinical examinations, are frequently used...
Who Has the Final Say? Decisions on Adolescent Behaviour within the Family.
ERIC Educational Resources Information Center
Bosma, Harke A.; And Others
1996-01-01
Utilizes the Perspectives on Adolescent Decision-Making Questionnaire to study the transition to adolescence and the changes it involves for the family. The instrument examines 21 issues that can lead to conflict. The instrument was completed by 500 Italian adolescents ages 13 and 15. Sensitivity to age and sex differences was examined.…
Alphus D. Wilson
2012-01-01
Electronic-detection technologies and instruments increasingly are being utilized in the biomedical field to perform a wide variety of clinical operations and laboratory analyses to facilitate the delivery of health care to patients. The introduction of improved electronic instruments for diagnosing diseases and for administering treatments has required new training of...
USDA-ARS?s Scientific Manuscript database
Moisture content of wood chips is an important factor to be known in their utilization as biomass material. Several moisture measuring instruments are available in the market, but for most of these instruments, some sort of sample preparation is needed that involves sizing, grinding and weighing. T...
Parents with Psychosis: A Pilot Study Examining Self-Report Measures Related to Family Functioning.
ERIC Educational Resources Information Center
Plant, Karen; Byrne, Linda; Barkla, Joanne; McLean, Duncan; Hearle, Jenny; McGrath, John
2002-01-01
Examines the utility of various self-report instruments related to family functioning in families where a parent has a psychotic disorder, and explores associations between these instruments and symptoms in the parent. There were significant associations between objective measures of negative symptoms and self-report scores related to problems in…
Effect of a Predictor Instrument on Learning to Land a Simulated Jet Trainer. Final Report.
ERIC Educational Resources Information Center
Smith, Russell L.; And Others
The study investigates the potential utility of a predictor instrument in the training of manual control operators in aircraft simulators. Various predictor display design configurations were presented to subjects during training trials on an aircraft approach to landing task. Subsequently, subjects were tested on trials devoid of the predictor…
ERIC Educational Resources Information Center
Ng, Betsy; Wang, C. K. John; Liu, W. C.
2017-01-01
The motivated strategies for learning questionnaire (MSLQ) is widely used as a self-report instrument to assess students' motivation and self-regulation. This study utilized the MSLQ Junior High to examine the motivational beliefs and self-regulation of secondary school students (Grades 8 and 9) from Singapore. The instrument was slightly modified…
ERIC Educational Resources Information Center
Villard, Judith A.; Earnest, Garee W.
2006-01-01
This descriptive-correlational study used a census of Ohio State University Extension county directors and a random sample of county staff throughout the State of Ohio. Data were collected utilizing Bar-On's Emotional Intelligence Quotient instrument (county directors) and Warner's job satisfaction instrument (county staff). The study examined the…
Exploring Gender and Self-Efficacy Ratings of Athletic Training Students over Time
ERIC Educational Resources Information Center
Carr, W. David; Volberding, Jennifer L.
2014-01-01
Objective: To describe the development of a self-efficacy instrument and to explore the changes by gender in student self-efficacy ratings over 1 year. Design and Setting: An exploratory study utilizing an instrument that measures self-efficacy in undergraduate students in a university setting. Patients or Other Participants: Thirty students (13…
1981-05-01
coating process in Explosives Manufacturing Line 2. The end products of the initial design effort are process flow diagrams, piping and...instrumentation diagrams, motor control schedules, interlock logic diagrams, piping installation drawings, typical instrument Installation details, equipment...structures, equipment, utilities, and process piping extending 1.5 m (5 ft) beyond the building or area were not included in the scope of work. Nitrolysis
ERIC Educational Resources Information Center
Dipeolu, Abiola O.
2007-01-01
Conventional wisdom in the area of assessment strongly supports the notion that instruments used for vocational or career decision-making purposes should possess sound psychometric properties. This study is a preliminary attempt to examine the reliability and validity of three important career decision-making measures administered to high school…
Demonstration of a Balloon Borne Arc-Second Pointer Design
NASA Technical Reports Server (NTRS)
DeWeese, Keith D.; Ward, Philip R.
2006-01-01
Many designs for utilizing stratospheric balloons as low-cost platforms on which to conduct space science experiments have been proposed throughout the years. A major hurdle in extending the range of experiments for which these vehicles are useful has been the imposition of the gondola dynamics on the accuracy with which an instrument can be kept pointed at a celestial target. A significant number of scientists have sought the ability to point their instruments with jitter in the arc-second range. This paper presents the design and analysis of a stratospheric balloon borne pointing system that is able to meet this requirement. The test results of a demonstration prototype of the design with similar ability are also presented. Discussion of a high fidelity controller simulation for design analysis is presented. The flexibility of the flight train is represented through generalized modal analysis. A multiple controller scheme is utilized for coarse and fine pointing. Coarse azimuth pointing is accomplished by an established pointing system, with extensive flight history, residing above the gondola structure. A pitch-yaw gimbal mount is used for fine pointing, providing orthogonal axes when nominally on target. Fine pointing actuation is from direct drive dc motors, eliminating backlash problems. An analysis of friction nonlinearities and a demonstration of the necessity in eliminating static friction are provided. A unique bearing hub design is introduced that eliminates static friction from the system dynamics. A control scheme involving linear accelerometers for enhanced disturbance rejection is also presented. Results from a linear analysis of the total system and the high fidelity simulation are given. Results from a generalized demonstration prototype are presented. Commercial off-the-shelf (COTS) hardware was used to demonstrate the efficacy and performance of the pointer design for a mock instrument. Sub-arcsecond pointing ability from a ground hang test setup is shown from the testing results. This paper establishes that the proposed control strategy can be made robustly stable with significant design margins. Also demonstrated is the efficacy of the proposed system in rejecting disturbances larger than those considered realistic. The system is implemented and demonstrates sub arc second pointing ability using COTS hardware. Finally, we see that sub arc-second pointing stability can be achieved for a large instrument pointing at an inertial target.
IRIS Arrays: Observing Wavefields at Multiple Scales and Frequencies
NASA Astrophysics Data System (ADS)
Sumy, D. F.; Woodward, R.; Frassetto, A.
2014-12-01
The Incorporated Research Institutions for Seismology (IRIS) provides instruments for creating and operating seismic arrays at a wide range of scales. As an example, for over thirty years the IRIS PASSCAL program has provided instruments to individual Principal Investigators to deploy arrays of all shapes and sizes on every continent. These arrays have ranged from just a few sensors to hundreds or even thousands of sensors, covering areas with dimensions of meters to thousands of kilometers. IRIS also operates arrays directly, such as the USArray Transportable Array (TA) as part of the EarthScope program. Since 2004, the TA has rolled across North America, at any given time spanning a swath of approximately 800 km by 2,500 km, and thus far sampling 2% of the Earth's surface. This achievement includes all of the lower-48 U.S., southernmost Canada, and now parts of Alaska. IRIS has also facilitated specialized arrays in polar environments and on the seafloor. In all cases, the data from these arrays are freely available to the scientific community. As the community of scientists who use IRIS facilities and data look to the future they have identified a clear need for new array capabilities. In particular, as part of its Wavefields Initiative, IRIS is exploring new technologies that can enable large, dense array deployments to record unaliased wavefields at a wide range of frequencies. Large-scale arrays might utilize multiple sensor technologies to best achieve observing objectives and optimize equipment and logistical costs. Improvements in packaging and power systems can provide equipment with reduced size, weight, and power that will reduce logistical constraints for large experiments, and can make a critical difference for deployments in harsh environments or other situations where rapid deployment is required. We will review the range of existing IRIS array capabilities with an overview of previous and current deployments and examples of data and results. We will review existing IRIS projects that explore new array capabilities and highlight future directions for IRIS instrumentation facilities.
NASA Astrophysics Data System (ADS)
Golightly, M. J.; McGarity, J. O.; Dichter, B. K.; Galica, G. E.
2015-12-01
The next generation U.S. geosynchronous weather satellite—GOES series R-U—will include for the first time a suprathermal plasma analyzer. The Magnetospheric Particle Sensor-Low (MPS-LO), an electrostatic analyzer utilizing triquadrispheric geometry (270° turn)deflection electrodes, will measure the flux of electrons and ions with energies between 30 eV - 30 keV in fifteen logarithmically-spaced differential energy channels and arrival direction in twelve angular bins. MPS-LO consists of two sensor heads mounted in a common electronics box. Each sensor head contains a set of deflection electrodes, microchannel plates, and segmented detector anodes. The common electronics box provides the power and I/O interface with a data processing unit, voltage supplies for all of the instrument's electronics, high voltage for the deflection electrodes, in-flight calibration pulsers, and the digital electronics to process signals from sensor heads' detector anodes. Great care was taken in the manufacture and mounting of the triquadrisphere deflection electrodes; each electrode was machined from a single piece of aluminum and specific electrode combinations were mounted with precision machined spacers and matched drilling. The precise fabrication and assembly resulted in near perfect spherical electric fields between the electrodes. The triquadrispheric electrode shape also prevents photons from reaching the detection elements-as a result, MPS-LO is solar blind. The combined field-of-view for the two sensor heads is 180° x 5°, with the larger angle in a plane perpendicular to the spacecraft's orbit and its central axis oriented anti-Earthward. An incident particle's arrival direction is determined in one of twelve 15° x 5° angular zones. A set of shielded anodes is used to measure the background caused by penetrating charged particles that reach the MCPs; this background data is used to correct the MPS-LO data. The instrument's energy resolution ΔE/E is 5.8%.
James, Alex S.; Pennington, Zachary T.; Tran, Phu
2015-01-01
Abstract Two theories regarding the role for dopamine neurons in learning include the concepts that their activity serves as a (1) mechanism that confers incentive salience onto rewards and associated cues and/or (2) contingency teaching signal reflecting reward prediction error. While both theories are provocative, the causal role for dopamine cell activity in either mechanism remains controversial. In this study mice that either fully or partially lacked NMDARs in dopamine neurons exclusively, as well as appropriate controls, were evaluated for reward-related learning; this experimental design allowed for a test of the premise that NMDA/glutamate receptor (NMDAR)-mediated mechanisms in dopamine neurons, including NMDA-dependent regulation of phasic discharge activity of these cells, modulate either the instrumental learning processes or the likelihood of pavlovian cues to become highly motivating incentive stimuli that directly attract behavior. Loss of NMDARs in dopamine neurons did not significantly affect baseline dopamine utilization in the striatum, novelty evoked locomotor behavior, or consumption of a freely available, palatable food solution. On the other hand, animals lacking NMDARs in dopamine cells exhibited a selective reduction in reinforced lever responses that emerged over the course of instrumental learning. Loss of receptor expression did not, however, influence the likelihood of an animal acquiring a pavlovian conditional response associated with attribution of incentive salience to reward-paired cues (sign tracking). These data support the view that reductions in NMDAR signaling in dopamine neurons affect instrumental reward-related learning but do not lend support to hypotheses that suggest that the behavioral significance of this signaling includes incentive salience attribution. PMID:26464985
NASA Astrophysics Data System (ADS)
Gleason, J. L.; Hillyer, T. N.
2011-12-01
Clouds and the Earth's Radiant Energy System (CERES) is one of NASA's highest priority Earth Observing System (EOS) scientific instruments. The CERES science team will integrate data from the CERES Flight Model 5 (FM5) on the NPOESS Preparatory Project (NPP) in addition to the four CERES scanning instrument on Terra and Aqua. The CERES production system consists of over 75 Product Generation Executives (PGEs) maintained by twelve subsystem groups. The processing chain fuses CERES instrument observations with data from 19 other unique sources. The addition of FM5 to over 22 instrument years of data to be reprocessed from flight models 1-4 creates a need for an optimized production processing approach. This poster discusses a new approach, using JBoss and Perl to manage job scheduling and interdependencies between PGEs and external data sources. The new optimized approach uses JBoss to serve handler servlets which regulate PGE-level job interdependencies and job completion notifications. Additional servlets are used to regulate all job submissions from the handlers and to interact with the operator. Perl submission scripts are used to build Process Control Files and to interact directly with the operating system and cluster scheduler. The result is a reduced burden on the operator by algorithmically enforcing a set of rules that determine the optimal time to produce data products with the highest integrity. These rules are designed on a per PGE basis and periodically change. This design provides the means to dynamically update PGE rules at run time and increases the processing throughput by using an event driven controller. The immediate notification of a PGE's completion (an event) allows successor PGEs to launch at the proper time with minimal start up latency, thereby increasing computer system utilization.
NASA Astrophysics Data System (ADS)
Gonzalez Abraham, R.; Zavala, M.; Molina, L. T.; Fortner, E.; Wormhoudt, J.; Knighton, B.; Herndon, S.; Roscioli, J. R.; Onasch, T. B.; Jayne, J. T.; Worsnop, D. R.; Kolb, C. E.; Masera, O.; Berrueta, V.
2013-12-01
Black carbon emissions are a major contributor to climate change, with cookstoves being one of the top sources. The SLCF cookstove study was conducted in March 2013 at the Interdisciplinary Group for Appropriate Rural Technology (GIRA) in Pátzcuaro, Mexico. Seven different types of wood-burning cookstoves were measured giving insight to the effects of different designs and operating conditions on particle and gas phase emissions. High-time resolution measurements of emissions were made. For most of the cookstoves, measurements were made throughout a standard water boiling test. The Aerodyne Mobile Laboratory conducted these emission measurements utilizing extractive sampling from the stove exhaust. Sample flow to the gas phase instruments was extracted directly from the stovepipe and then quickly diluted with nitrogen. Sample flows for the particulate instruments were taken at points under a meter from the exit of the stovepipe, after dilution with ambient air. The key particulate instrument was the Aerodyne soot particle aerosol mass spectrometer (SP-AMS), which provided measurements of black carbon, divided into several sub-components, along with other classes of particulate matter classified by chemical composition. Gas phase measurements conducted included CO, CO2, NO, NOx, SO2, CH4, C2H2, C2H6, and a variety of VOCs (including benzene, methanol, acetaldehyde, toluene, acetone, acetonitrile, and terpene) measured with a PTR-MS instrument. All of these measurements will be examined to construct emission ratios evaluating how these vary with different cookstove types and different stove operating conditions. Comparisons will be made to previous measurements of cookstove emissions in the literature, with a focus on the variety of particulate measurements reported.
TAIPAN instrument fibre positioner and Starbug robots: engineering overview
NASA Astrophysics Data System (ADS)
Staszak, Nicholas F.; Lawrence, Jon; Brown, David M.; Brown, Rebecca; Zhelem, Ross; Goodwin, Michael; Kuehn, Kyler; Lorente, Nuria P. F.; Nichani, Vijay; Waller, Lew; Case, Scott; Content, Robert; Hopkins, Andrew M.; Klauser, Urs; Pai, Naveen; Mueller, Rolf; Mali, Slavko; Vuong, Minh V.
2016-07-01
TAIPAN will conduct a stellar and galaxy survey of the Southern sky. The TAIPAN positioner is being developed as a prototype for the MANIFEST instrument on the GMT. The design for TAIPAN incorporates 150 optical fibres (with an upgrade path to 300) situated within independently controlled robotic positioners known as Starbugs. Starbugs allow precise parallel positioning of individual fibres, thus significantly reducing instrument configuration time and increasing the amount of observing time. Presented is an engineering overview of the UKST upgrade of the completely new Instrument Spider Assembly utilized to support the Starbug Fibre Positioning Robot and current status of the Starbug itself.
McStas-model of the delft SESANS
NASA Astrophysics Data System (ADS)
Knudsen, E.; Udby, L.; Willendrup, P. K.; Lefmann, K.; Bouwman, W. G.
2011-06-01
We present simulation results taking first virtual data from a model of the Spin-Echo Small Angle Scattering (SESANS) instrument situated in Delft, in the framework of the McStas Monte Carlo software package. The main focus has been on making a model of the Delft SESANS instrument, and we can now present the first virtual data from it, using a refracting prism-like sample model. In consequence, polarisation instrumentation is now included natively in the McStas kernel, including options for magnetic fields and a number of utility components. This development has brought us to a point where realistic models of polarisation-enabled instrumentation can be built.
Double-Pulse Two-Micron IPDA Lidar Simulation for Airborne Carbon Dioxide Measurements
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta
2015-01-01
An advanced double-pulsed 2-micron integrated path differential absorption lidar has been developed at NASA Langley Research Center for measuring atmospheric carbon dioxide. The instrument utilizes a state-of-the-art 2-micron laser transmitter with tunable on-line wavelength and advanced receiver. Instrument modeling and airborne simulations are presented in this paper. Focusing on random errors, results demonstrate instrument capabilities of performing precise carbon dioxide differential optical depth measurement with less than 3% random error for single-shot operation from up to 11 km altitude. This study is useful for defining CO2 measurement weighting, instrument setting, validation and sensitivity trade-offs.
Assessment of Work Performance (AWP)--development of an instrument.
Sandqvist, Jan L; Törnquist, Kristina B; Henriksson, Chris M
2006-01-01
Adequate work assessments are a matter of importance both for individuals and society [5,29,31,38,40,46,52]. However, there is a lack of adequate and reliable instruments for use in work rehabilitation [14,15,20,21,31,44]. The purpose of this study was to develop and evaluate an observation instrument for assessing work performance, the AWP (Assessment of Work Performance). The purpose of the 14-item instrument is to assess the individual's observable working skills in three different areas: motor skills, process skills, and communication and interaction skills. This article describes the development and results of preliminary testing of the AWP. The testing indicates a satisfactory face validity and utility for the AWP and supports further research and testing of the instrument.
Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas
2016-11-01
This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time monitors is convenient for measurement of airborne PM at short time scales, the accuracy of those monitors depends on a particular instrument. Bias correction factors identified in this paper could provide guidance for other studies using direct-reading instruments to measure PM concentrations.
Ground-based Instrumentations in Africa and its Scientific and Societal Benefits to the region
NASA Astrophysics Data System (ADS)
Yizengaw, Endawoke
2012-07-01
Much of what we know about equatorial physics is based on Jicamarca Incoherent Scattering Radar (ISR) observations. However, Jicamarca is in the American sector where the geomagnetic equator dips with a fairly large excursion between the geomagnetic and geodetic equator. On the other hand, in the African sector the geomagnetic equator is fairly well aligned with the geodetic equator. Satellites (e.g. ROCSAT, DMSP, C/NOFS) observations have also indicated that the equatorial ionosphere in the African sector responds differently than other sectors. However, these satellite observations have not been confirmed, validated or studied in detail by observations from the ground due to lack of suitable ground-based instrumentation in the region. Thus, the question of what causes or drives these unique density irregularities in the region is still not yet fully understood, leading the investigation of the physics behind each effect into speculative dead ends. During the past couple of years very few (compared to the land-mass that Africa covers) small instruments, like GPS receivers, magnetometers, VHF, and VLF have been either deployed in the region or in process. However, to understand the most dynamic region in terms of ionospheric irregularities, those few instruments are far from enough. Recently, significant progress has been emerging in securing more ground-based instrument into the region, and thus three ionosondes are either deployed or in process. In this paper, results from AMBER magnetometer network, ionosonde, and GPS receivers will be presented. By combining the multi instrument independent observations, this paper will show a cause and effect of space weather impact in the region for the first time. While the magnetometer network, such as those operated under the umbrella of AMBER project, estimates the fundamental electrodynamics that governs equatorial ionospheric motion, the GPS receivers will track the structure and dynamics of the ionosphere. In addition to the scientific importance, the ground-based instrumentations have also direct impact in advancing space science research by establishing and furthering sustainable research/training infrastructure within Africa so that more young scientists will be educated in their own country. The paper will present research results performed by graduate students who utilize data from the recently deployed instruments within the African universities.
A retarding ion mass spectrometer for the Dynamics Explorer-1
NASA Technical Reports Server (NTRS)
Wright, W.
1985-01-01
The Retarding Ion Mass Spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.
Does the choice of tariff matter?
Zhao, Yue; Li, Shun-Ping; Liu, Liu; Zhang, Jiang-Lin; Chen, Gang
2017-01-01
Abstract There is an increasing trend globally to develop country-specific tariffs that can theoretically better reflect population's preferences on health states for preference-based health-related quality-of-life instruments, also known as multiattribute utility instruments. This study focused on the most recently developed 5-level version of EuroQol-5 Dimension (EQ-5D) questionnaire, 1 of the world's most well-known multiattribute utility instruments, and aimed to empirically explore the agreements and known-group validities of applying the country-specific tariff versus tariffs developed from other countries using a sample of psoriasis vulgaris patients in Mainland China. A convenience sampling framework was adopted to recruit patients diagnosed with psoriasis vulgaris from Xiangya Hospital, Central South University, China, between May 2014 and February 2015. The 5-level EuroQol-5 dimensions (EQ-5D-5L) utilities were scored by using the Chinese, Japanese, and UK tariffs. Health state utilities were compared using a range of nonparametric test. The intraclass correlation coefficients and Bland–Altman plots were used to examine the agreements among the 3 EQ-5D-5L scores. Health state utility decrements between known groups were investigated using both effect size and a regression analysis. In all, 350 patients (aged 16 years or older) were recruited. There were significant differences among the 3 national tariff sets. Overall, 3 tariffs showed excellent agreements (intraclass correlation coefficient >0.90); however, the wide limits of agreement from the Bland–Altman plots suggest that these tariffs cannot be used interchangeably. The EQ-5D-5L scores using the Chinese-specific tariff showed the best known-group validity than the other 2 tariffs in this Chinese patient sample. The evidence from this study supports the choice of the country-specific tariff to be used in Mainland China. PMID:28834893
Titan LEAF: A Sky Rover Granting Targeted Access to Titan's Lakes and Plains
NASA Astrophysics Data System (ADS)
Ross, Floyd; Lee, Greg; Sokol, Daniel; Goldman, Benjamin; Bolisay, Linden
2016-10-01
Northrop Grumman, in collaboration with L'Garde Inc. and Global Aerospace Corporation (GAC), has been developing the Titan Lifting Entry Atmospheric Flight (T-LEAF) sky rover to roam the atmosphere and observe at close quarters the lakes and plains of Titan. T-LEAF also supports surface exploration and science by providing precision delivery of in situ instruments to the surface.T-LEAF is a maneuverable, buoyant air vehicle. Its aerodynamic shape provides its maneuverability, and its internal helium envelope reduces propulsion power requirements and also the risk of crashing. Because of these features, T-LEAF is not restricted to following prevailing wind patterns. This freedom of mobility allows it be commanded to follow the shorelines of Titan's methane lakes, for example, or to target very specific surface locations.T-LEAF utilizes a variable power propulsion system, from high power at ~200W to low power at ~50W. High power mode uses the propellers and control surfaces for additional mobility and maneuverability. It also allows the vehicle to hover over specific locations for long duration surface observations. Low power mode utilizes GAC's Titan Winged Aerobot (TWA) concept, currently being developed with NASA funding, which achieves guided flight without the use of propellers or control surfaces. Although slower than high powered flight, this mode grants increased power to science instruments while still maintaining control over direction of travel.Additionally, T-LEAF is its own entry vehicle, with its leading edges protected by flexible thermal protection system (f-TPS) materials already being tested by NASA's Hypersonic Inflatable Aerodynamic Decelerator (HIAD) group. This f-TPS technology allows T-LEAF to inflate in space, like HIAD, and then enter the atmosphere fully deployed. This approach accommodates entry velocities from as low as ~1.8 km/s if entering from Titan orbit, up to ~6 km/s if entering directly from Saturn orbit, like the Huygens probe.This presentation will discuss each of these topic areas, showing that a sky rover like T-LEAF is an ideal option for exploration of both the surface and atmosphere of Titan.
NASA Technical Reports Server (NTRS)
Zemba, Michael; Nessel, James; Houts, Jacquelynne; Luini, Lorenzo; Riva, Carlo
2016-01-01
The rain rate data and statistics of a location are often used in conjunction with models to predict rain attenuation. However, the true attenuation is a function not only of rain rate, but also of the drop size distribution (DSD). Generally, models utilize an average drop size distribution (Laws and Parsons or Marshall and Palmer. However, individual rain events may deviate from these models significantly if their DSD is not well approximated by the average. Therefore, characterizing the relationship between the DSD and attenuation is valuable in improving modeled predictions of rain attenuation statistics. The DSD may also be used to derive the instantaneous frequency scaling factor and thus validate frequency scaling models. Since June of 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have jointly conducted a propagation study in Milan, Italy utilizing the 20 and 40 GHz beacon signals of the Alphasat TDP#5 Aldo Paraboni payload. The Ka- and Q-band beacon receivers provide a direct measurement of the signal attenuation while concurrent weather instrumentation provides measurements of the atmospheric conditions at the receiver. Among these instruments is a Thies Clima Laser Precipitation Monitor (optical disdrometer) which yields droplet size distributions (DSD); this DSD information can be used to derive a scaling factor that scales the measured 20 GHz data to expected 40 GHz attenuation. Given the capability to both predict and directly observe 40 GHz attenuation, this site is uniquely situated to assess and characterize such predictions. Previous work using this data has examined the relationship between the measured drop-size distribution and the measured attenuation of the link]. The focus of this paper now turns to a deeper analysis of the scaling factor, including the prediction error as a function of attenuation level, correlation between the scaling factor and the rain rate, and the temporal variability of the drop size distribution both within a given rain event and across different varieties of rain events. Index Terms-drop size distribution, frequency scaling, propagation losses, radiowave propagation.
NASA Technical Reports Server (NTRS)
Zemba, Michael; Nessel, James; Houts, Jacquelynne; Luini, Lorenzo; Riva, Carlo
2016-01-01
The rain rate data and statistics of a location are often used in conjunction with models to predict rain attenuation. However, the true attenuation is a function not only of rain rate, but also of the drop size distribution (DSD). Generally, models utilize an average drop size distribution (Laws and Parsons or Marshall and Palmer [1]). However, individual rain events may deviate from these models significantly if their DSD is not well approximated by the average. Therefore, characterizing the relationship between the DSD and attenuation is valuable in improving modeled predictions of rain attenuation statistics. The DSD may also be used to derive the instantaneous frequency scaling factor and thus validate frequency scaling models. Since June of 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have jointly conducted a propagation study in Milan, Italy utilizing the 20 and 40 GHz beacon signals of the Alphasat TDP#5 Aldo Paraboni payload. The Ka- and Q-band beacon receivers provide a direct measurement of the signal attenuation while concurrent weather instrumentation provides measurements of the atmospheric conditions at the receiver. Among these instruments is a Thies Clima Laser Precipitation Monitor (optical disdrometer) which yields droplet size distributions (DSD); this DSD information can be used to derive a scaling factor that scales the measured 20 GHz data to expected 40 GHz attenuation. Given the capability to both predict and directly observe 40 GHz attenuation, this site is uniquely situated to assess and characterize such predictions. Previous work using this data has examined the relationship between the measured drop-size distribution and the measured attenuation of the link [2]. The focus of this paper now turns to a deeper analysis of the scaling factor, including the prediction error as a function of attenuation level, correlation between the scaling factor and the rain rate, and the temporal variability of the drop size distribution both within a given rain event and across different varieties of rain events. Index Terms-drop size distribution, frequency scaling, propagation losses, radiowave propagation.
Application of a model of instrumental conditioning to mobile robot control
NASA Astrophysics Data System (ADS)
Saksida, Lisa M.; Touretzky, D. S.
1997-09-01
Instrumental conditioning is a psychological process whereby an animal learns to associate its actions with their consequences. This type of learning is exploited in animal training techniques such as 'shaping by successive approximations,' which enables trainers to gradually adjust the animal's behavior by giving strategically timed reinforcements. While this is similar in principle to reinforcement learning, the real phenomenon includes many subtle effects not considered in the machine learning literature. In addition, a good deal of domain information is utilized by an animal learning a new task; it does not start from scratch every time it learns a new behavior. For these reasons, it is not surprising that mobile robot learning algorithms have yet to approach the sophistication and robustness of animal learning. A serious attempt to model instrumental learning could prove fruitful for improving machine learning techniques. In the present paper, we develop a computational theory of shaping at a level appropriate for controlling mobile robots. The theory is based on a series of mechanisms for 'behavior editing,' in which pre-existing behaviors, either innate or previously learned, can be dramatically changed in magnitude, shifted in direction, or otherwise manipulated so as to produce new behavioral routines. We have implemented our theory on Amelia, an RWI B21 mobile robot equipped with a gripper and color video camera. We provide results from training Amelia on several tasks, all of which were constructed as variations of one innate behavior, object-pursuit.
[The concept of autonomy (synthetic and operation indicators of old age : a systemic approach).].
Lebeau, A; Sicotte, C; Tilquin, C; Tremblay, L
1980-01-01
The present study is a follow-up of a research project made in 1978 by the Equipe de Recherche Opérationnelle en Santé (EROS) of the Department of Health Administration at the Université de Montréal. The aims were a) firstly to construct a classification instrument by type for long-term care patients, enabling us, to identify these beneficiaries' needs, as well as to guide their placement in a health services' system. And b) to evaluate this instrument (realibility and validity), c) to initiate its implementation and d) to utilize it for evaluating the present placement system. This study constitutes the first stage in an approach aimed at producing, on the basis of a systematic scanning of data collected within the framework of the above-mentioned project; a comprehensive descriptive analysis of the social/health characteristics of an aged population (65 years and over) in one of Quebec's social/ health regions i.e. Montreal's South Shore. At first, the authors define the context and the objectives of the study undertaken; secondly, they define the concept of autonomy by showing how the latter is expressed concretely according to the observation instrument (evaluation form of the individual's functional autonomy). Thirdly, a presentation is made of the method of measurement, as well as certain results concerning an index of restricted autonomy directly released to situations of observable behaviour (e, g. daily-life activities, exploring the outside world, and housekeeping).
Rapid identification of bacteria with miniaturized pyrolysis/GC analysis
NASA Astrophysics Data System (ADS)
Morgan, Catherine H.; Mowry, Curtis; Manginell, Ronald P.; Frye-Mason, Gregory C.; Kottenstette, Richard J.; Lewis, Patrick
2001-02-01
Identification of bacteria and other biological moieties finds a broad range of applications in the environmental, biomedical, agricultural, industrial, and military arenas. Linking these applications are biological markers such as fatty acids, whose mass spectral profiles can be used to characterize biological samples and to distinguish bacteria at the gram-type, genera, and even species level. Common methods of sample analysis require sample preparation that is both lengthy and labor intensive, especially for whole cell bacteria. The background technique relied on here utilizes chemical derivatization of fatty acids to the more volatile fatty acid methyl esters (FAMEs), which can be separated on a gas chromatograph column or input directly into a mass spectrometer. More recent publications demonstrate improved sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis at the inlet; although much faster than traditional techniques, these systems still rely on bench-top analytical equipment and individual sample preparation. Development of a miniaturized pyrolysis/GC instrument by this group is intended to realize the benefits of FAME identification of bacteria and other biological samples while further facilitating sample handling and instrument portability. The technologies being fabricated and tested have the potential of achieving pyrolysis and FAME separation on a very small scale, with rapid detection time (1-10 min from introduction to result), and with a modular sample inlet. Performance results and sensor characterization will be presented for the first phase of instrument development, encompassing the microfabricated pyrolysis and gas chromatograph elements.
Visual tracking for multi-modality computer-assisted image guidance
NASA Astrophysics Data System (ADS)
Basafa, Ehsan; Foroughi, Pezhman; Hossbach, Martin; Bhanushali, Jasmine; Stolka, Philipp
2017-03-01
With optical cameras, many interventional navigation tasks previously relying on EM, optical, or mechanical guidance can be performed robustly, quickly, and conveniently. We developed a family of novel guidance systems based on wide-spectrum cameras and vision algorithms for real-time tracking of interventional instruments and multi-modality markers. These navigation systems support the localization of anatomical targets, support placement of imaging probe and instruments, and provide fusion imaging. The unique architecture - low-cost, miniature, in-hand stereo vision cameras fitted directly to imaging probes - allows for an intuitive workflow that fits a wide variety of specialties such as anesthesiology, interventional radiology, interventional oncology, emergency medicine, urology, and others, many of which see increasing pressure to utilize medical imaging and especially ultrasound, but have yet to develop the requisite skills for reliable success. We developed a modular system, consisting of hardware (the Optical Head containing the mini cameras) and software (components for visual instrument tracking with or without specialized visual features, fully automated marker segmentation from a variety of 3D imaging modalities, visual observation of meshes of widely separated markers, instant automatic registration, and target tracking and guidance on real-time multi-modality fusion views). From these components, we implemented a family of distinct clinical and pre-clinical systems (for combinations of ultrasound, CT, CBCT, and MRI), most of which have international regulatory clearance for clinical use. We present technical and clinical results on phantoms, ex- and in-vivo animals, and patients.
Stray-Light Correction of the Marine Optical Buoy
NASA Technical Reports Server (NTRS)
Brown, Steven W.; Johnson, B. Carol; Flora, Stephanie J.; Feinholz, Michael E.; Yarbrough, Mark A.; Barnes, Robert A.; Kim, Yong Sung; Lykke, Keith R.; Clark, Dennis K.
2003-01-01
In ocean-color remote sensing, approximately 90% of the flux at the sensor originates from atmospheric scattering, with the water-leaving radiance contributing the remaining 10% of the total flux. Consequently, errors in the measured top-of-the atmosphere radiance are magnified a factor of 10 in the determination of water-leaving radiance. Proper characterization of the atmosphere is thus a critical part of the analysis of ocean-color remote sensing data. It has always been necessary to calibrate the ocean-color satellite sensor vicariously, using in situ, ground-based results, independent of the status of the pre-flight radiometric calibration or the utility of on-board calibration strategies. Because the atmosphere contributes significantly to the measured flux at the instrument sensor, both the instrument and the atmospheric correction algorithm are simultaneously calibrated vicariously. The Marine Optical Buoy (MOBY), deployed in support of the Earth Observing System (EOS) since 1996, serves as the primary calibration station for a variety of ocean-color satellite instruments, including the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), the Moderate Resolution Imaging Spectroradiometer (MODIS), the Japanese Ocean Color Temperature Scanner (OCTS) , and the French Polarization and Directionality of the Earth's Reflectances (POLDER). MOBY is located off the coast of Lanai, Hawaii. The site was selected to simplify the application of the atmospheric correction algorithms. Vicarious calibration using MOBY data allows for a thorough comparison and merger of ocean-color data from these multiple sensors.
Characterizing nonconstant instrumental variance in emerging miniaturized analytical techniques.
Noblitt, Scott D; Berg, Kathleen E; Cate, David M; Henry, Charles S
2016-04-07
Measurement variance is a crucial aspect of quantitative chemical analysis. Variance directly affects important analytical figures of merit, including detection limit, quantitation limit, and confidence intervals. Most reported analyses for emerging analytical techniques implicitly assume constant variance (homoskedasticity) by using unweighted regression calibrations. Despite the assumption of constant variance, it is known that most instruments exhibit heteroskedasticity, where variance changes with signal intensity. Ignoring nonconstant variance results in suboptimal calibrations, invalid uncertainty estimates, and incorrect detection limits. Three techniques where homoskedasticity is often assumed were covered in this work to evaluate if heteroskedasticity had a significant quantitative impact-naked-eye, distance-based detection using paper-based analytical devices (PADs), cathodic stripping voltammetry (CSV) with disposable carbon-ink electrode devices, and microchip electrophoresis (MCE) with conductivity detection. Despite these techniques representing a wide range of chemistries and precision, heteroskedastic behavior was confirmed for each. The general variance forms were analyzed, and recommendations for accounting for nonconstant variance discussed. Monte Carlo simulations of instrument responses were performed to quantify the benefits of weighted regression, and the sensitivity to uncertainty in the variance function was tested. Results show that heteroskedasticity should be considered during development of new techniques; even moderate uncertainty (30%) in the variance function still results in weighted regression outperforming unweighted regressions. We recommend utilizing the power model of variance because it is easy to apply, requires little additional experimentation, and produces higher-precision results and more reliable uncertainty estimates than assuming homoskedasticity. Copyright © 2016 Elsevier B.V. All rights reserved.
Johnson, W B; Lall, R; Bongar, B; Nordlund, M D
1999-01-01
Objective personality assessment instruments offer a comparatively underutilized source of clinical data in attempts to evaluate and predict risk for suicide. In contrast to focal suicide risk measures, global personality inventories may be useful in identification of long-standing styles that predispose persons to eventual suicidal behavior. This article reviews the empirical literature regarding the efficacy of established personality inventories in predicting suicidality. The authors offer several recommendations for future research with these measures and conclude that such objective personality instruments offer only marginal utility as sources of clinical information in comprehensive suicide risk evaluations. Personality inventories may offer greatest utility in long-term assessment of suicide risk.
NASA Technical Reports Server (NTRS)
Cassell, Alan M.
2013-01-01
The testing of 3- and 6-meter diameter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test articles was completed in the National Full-Scale Aerodynamics Complex 40 ft x 80 ft Wind Tunnel test section. Both models were stacked tori, constructed as 60 degree half-angle sphere cones. The 3-meter HIAD was tested in two configurations. The first 3-meter configuration utilized an instrumented flexible aerodynamic skin covering the inflatable aeroshell surface, while the second configuration employed a flight-like flexible thermal protection system. The 6-meter HIAD was tested in two structural configurations (with and without an aft-mounted stiffening torus near the shoulder), both utilizing an instrumented aerodynamic skin.
Brown, Gary C; Brown, Melissa M
2009-05-01
To familiarize the clinician with the concept of comparative effectiveness. Recent data support the concept that utility analysis is the quality-of-life instrument best able to perform comparative effectiveness analyses. The use of time tradeoff utilities for comparative effectiveness analyses in interventions across diverse specialties of medicine can be undertaken with both excellent reliability and superior construct validity. Physicians should familiarize themselves with quality-of-life instruments that can be used to assess the comparative effectiveness of healthcare interventions. Rather than delegating comparative effectiveness to others, physicians must become involved in creating and implementing comparative effectiveness standards. Physician involvement is crucial for the best interests of patients, as physicians most intimately understand the complexities and nuances associated with healthcare interventions.
Using Faculty Characteristics to Predict Attitudes toward Developmental Education
ERIC Educational Resources Information Center
Sides, Meredith Louise Carr
2017-01-01
The study adapted Astin's I-E-O model and utilized multiple regression analyses to predict faculty attitudes toward developmental education. The study utilized a cross-sectional survey design to survey faculty members at 27 different higher education institutions in the state of Alabama. The survey instrument was a self-designed questionnaire that…
Reliability, Validity and Utility of a Multiple Intelligences Assessment for Career Planning.
ERIC Educational Resources Information Center
Shearer, C. Branton
"The Multiple Intelligences Developmental Assessment Scales" (MIDAS) is a self- (or other-) completed instrument which is based upon the theory of multiple intelligences. The validity, reliability, and utility data regarding the MIDAS are reported here. The measure consists of 7 main scales and 24 subscales which summarize a person's intellectual…
14 CFR 25.1331 - Instruments using a power supply.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Instruments: Installation § 25... may be accomplished automatically or by manual means. (3) If an instrument presenting navigation data... gyroscopic direction indicator that includes a magnetic sensing element, a gyroscopic unit, an amplifier and...
Instrument Remote Control Application Framework
NASA Technical Reports Server (NTRS)
Ames, Troy; Hostetter, Carl F.
2006-01-01
The Instrument Remote Control (IRC) architecture is a flexible, platform-independent application framework that is well suited for the control and monitoring of remote devices and sensors. IRC enables significant savings in development costs by utilizing extensible Markup Language (XML) descriptions to configure the framework for a specific application. The Instrument Markup Language (IML) is used to describe the commands used by an instrument, the data streams produced, the rules for formatting commands and parsing the data, and the method of communication. Often no custom code is needed to communicate with a new instrument or device. An IRC instance can advertise and publish a description about a device or subscribe to another device's description on a network. This simple capability of dynamically publishing and subscribing to interfaces enables a very flexible, self-adapting architecture for monitoring and control of complex instruments in diverse environments.
The direct liquefaction proof of concept program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Comolli, A.G.; Lee, L.K.; Pradhan, V.R.
1995-12-31
The goal of the Proof of Concept (POC) Program is to develop Direct Coal Liquefaction and associated transitional technologies towards commercial readiness for economically producing premium liquid fuels from coal in an environmentally acceptable manner. The program focuses on developing the two-stage liquefaction (TSL) process by utilizing geographically strategic feedstocks, commercially feasible catalysts, new prototype equipment, and testing co-processing or alternate feedstocks and improved process configurations. Other high priority objectives include dispersed catalyst studies, demonstrating low rank coal liquefaction without solids deposition, improving distillate yields on a unit reactor volume basis, demonstrating ebullated bed operations while obtaining scale-up data, demonstratingmore » optimum catalyst consumption using new concepts (e.g. regeneration, cascading), producing premium products through on-line hydrotreating, demonstrating improved hydrogen utilization for low rank coals using novel heteroatom removal methods, defining and demonstrating two-stage product properties for upgrading; demonstrating efficient and economic solid separation methods, examining the merits of integrated coal cleaning, demonstrating co-processing, studying interactions between the preheater and first and second-stage reactors, improving process operability by testing and incorporating advanced equipment and instrumentation, and demonstrating operation with alternate coal feedstocks. During the past two years major PDU Proof of Concept runs were completed. POC-1 with Illinois No. 6 coal and POC-2 with Black Thunder sub-bituminous coal. Results from these operations are continuing under review and the products are being further refined and upgraded. This paper will update the results from these operations and discuss future plans for the POC program.« less
Peak exposures in aluminium potrooms: instrument development and field calibration.
Carter, Stephanie R; Seixas, Noah S; Thompson, Mary Lou; Yost, Michael G
2004-11-01
Aluminium smelter potrooms are unique in that workplace exposures to hydrogen fluoride (HF), sulfur dioxide (SO2), and particulate matter occur simultaneously for some tasks. The peak exposures to these contaminants are of increasing interest in discovering the etiology of respiratory health effects. While a variety of direct-reading instruments are available for sulfur dioxide and particulate matter, only a few exist for hydrogen fluoride. The sensors in these HF instruments have a cross-sensitivity to sulfur dioxide making it difficult to monitor HF in an environment that also contains SO2. To overcome this problem, we assessed the simultaneous use of two electrochemical instruments: one with a SO2 sensor that does not respond to HF and the second with a hydrogen fluoride sensor that responds to both HF and SO2 in a 1 : 1 ratio, termed 'total acid gas'. The difference in the response between the two instruments should indicate the HF concentration: [HF + SO2] minus SO2 equals HF. The performance characteristics of this sampling train were evaluated in the laboratory through the generation of both HF and SO2 with permeation tubes. The response and recovery times for the SO2 only instrument were acceptable (6 and 15 s, respectively), but the "total acid gas" instrument exhibited both slow response and slow recovery approaching three and six min. The association between the traditional integrated filter sampling method and the direct-reading instrument for SO2 is 0.80 (Spearman's rho). The use of the digital filter strengthens the association between the HF direct-reading instrument and the integrated samples from 0.41 to 0.68.
NASA Technical Reports Server (NTRS)
1976-01-01
Developments in applying aerospace medical technology to the design and production of medical equipment and instrumentation are reported. Projects described include intercranial pressure transducers, leg negative pressure devices, a synthetic speech prosthesis for victims of cerebral palsy, and a Doppler blood flow instrument. Commercialization activities for disseminating and utilizing NASA technology, and new biomedical problem areas are discussed.
ERIC Educational Resources Information Center
Tantilipikorn, Pinailug; Watter, Pauline; Prasertsukdee, Saipin
2013-01-01
Health-related quality of life (HRQOL) is increasingly being considered in the management of patients with various conditions. HRQOL instruments can be broadly classified as generic or disease-specific measures. Several generic HRQOL instruments in different languages have been developed for paediatric populations including the Pediatric Quality…
ERIC Educational Resources Information Center
Mazefsky, Carla A.; Oswald, Donald P.
2006-01-01
Recent years have seen a surge of interest in assessment instruments for diagnosing autism in children. Instruments have generally been developed and evaluated from a research perspective. The Autism Diagnostic Observation Schedule-Generic (ADOS-G), Autism Diagnostic Interview-Revised (ADI-R), and Gilliam Autism Rating Scale (GARS) have received…
A Helium GC/IMS for the Analysis of Extraterrestrial Volatiles in Exobiology Flight Experiments
NASA Technical Reports Server (NTRS)
Kojiro, Daniel R.; Carle, Glenn C.; Humphry, Donald E.; Shao, Maxine; Takeuchi, Nori
1995-01-01
For exobiology experiments on board spacecraft or space probes, a wide range of chemical species often must be detected and identified. The limited amount of power and space available for flight instruments severely limits the number of instruments that can be flown on any given mission. It is important then, that these experiments utilize instrumentation with universal response, so that all species of interest can be analyzed. Instrumentation to fulfill the analytical requirements of exobiology experiments has been developed utilizing Gas Chromatography - Ion Mobility Spectrometry. The Gas Chromatograph (GC) combines columns developed specifically for the complex mixtures anticipated with highly sensitive Metastable Ionization Detectors (a type of Helium Ionization Detector). To satisfy the limitations placed on resources, the Ion Mobility Spectrometer (IMS) uses the same ultra high purity helium as the GC. This GC-MS provides the analytical capability to fulfill a wide range of exobiology flight experiment applications and has been included on a proposed Discovery Mission and proposals for both Lander and Orbiter of the European Space Agency's Rosetta Comet Mission. A data base of helium IMS spectra is now being built for these future applications.
Measures of Cultural Competence in Nurses: An Integrative Review
2013-01-01
Background. There is limited literature available identifying and describing the instruments that measure cultural competence in nursing students and nursing professionals. Design. An integrative review was undertaken to identify the characteristics common to these instruments, examine their psychometric properties, and identify the concepts these instruments are designed to measure. Method. There were eleven instruments identified that measure cultural competence in nursing. Of these eleven instruments, four had been thoroughly tested in either initial development or in subsequent testing, with developers providing extensive details of the testing. Results. The current literature identifies that the instruments to assess cultural competence in nurses and nursing students are self-administered and based on individuals' perceptions. The instruments are commonly utilized to test the effectiveness of educational programs designed to increase cultural competence. Conclusions. The reviewed instruments measure nurses' self-perceptions or self-reported level of cultural competence but offer no objective measure of culturally competent care from a patient's perspective which can be problematic. Comparison of instruments reveals that they are based on a variety of conceptual frameworks and that multiple factors should be considered when deciding which instrument to use. PMID:23818818
Low-Dimensional Feature Representation for Instrument Identification
NASA Astrophysics Data System (ADS)
Ihara, Mizuki; Maeda, Shin-Ichi; Ikeda, Kazushi; Ishii, Shin
For monophonic music instrument identification, various feature extraction and selection methods have been proposed. One of the issues toward instrument identification is that the same spectrum is not always observed even in the same instrument due to the difference of the recording condition. Therefore, it is important to find non-redundant instrument-specific features that maintain information essential for high-quality instrument identification to apply them to various instrumental music analyses. For such a dimensionality reduction method, the authors propose the utilization of linear projection methods: local Fisher discriminant analysis (LFDA) and LFDA combined with principal component analysis (PCA). After experimentally clarifying that raw power spectra are actually good for instrument classification, the authors reduced the feature dimensionality by LFDA or by PCA followed by LFDA (PCA-LFDA). The reduced features achieved reasonably high identification performance that was comparable or higher than those by the power spectra and those achieved by other existing studies. These results demonstrated that our LFDA and PCA-LFDA can successfully extract low-dimensional instrument features that maintain the characteristic information of the instruments.
Zhao, Yue; Li, Shun-Ping; Liu, Liu; Zhang, Jiang-Lin; Chen, Gang
2017-08-01
There is an increasing trend globally to develop country-specific tariffs that can theoretically better reflect population's preferences on health states for preference-based health-related quality-of-life instruments, also known as multiattribute utility instruments. This study focused on the most recently developed 5-level version of EuroQol-5 Dimension (EQ-5D) questionnaire, 1 of the world's most well-known multiattribute utility instruments, and aimed to empirically explore the agreements and known-group validities of applying the country-specific tariff versus tariffs developed from other countries using a sample of psoriasis vulgaris patients in Mainland China.A convenience sampling framework was adopted to recruit patients diagnosed with psoriasis vulgaris from Xiangya Hospital, Central South University, China, between May 2014 and February 2015. The 5-level EuroQol-5 dimensions (EQ-5D-5L) utilities were scored by using the Chinese, Japanese, and UK tariffs. Health state utilities were compared using a range of nonparametric test. The intraclass correlation coefficients and Bland-Altman plots were used to examine the agreements among the 3 EQ-5D-5L scores. Health state utility decrements between known groups were investigated using both effect size and a regression analysis.In all, 350 patients (aged 16 years or older) were recruited. There were significant differences among the 3 national tariff sets. Overall, 3 tariffs showed excellent agreements (intraclass correlation coefficient >0.90); however, the wide limits of agreement from the Bland-Altman plots suggest that these tariffs cannot be used interchangeably. The EQ-5D-5L scores using the Chinese-specific tariff showed the best known-group validity than the other 2 tariffs in this Chinese patient sample. The evidence from this study supports the choice of the country-specific tariff to be used in Mainland China.
[Some critical remarks on standardised assessment instruments in nursing].
Bartholomeyczik, Sabine
2007-08-01
The use of standardised instruments in nursing has rapidly grown and can be seen as a symptom of the necessary comprehensive nursing diagnostics. However, these instruments comprise the risk of misuse, if they are not critically evaluated. Published statements about tests of reliability and validity of an instrument are insufficient. First, the critical evaluation has to ask for the instrument's theoretical and content base: Is the instrument relevant for nursing, suitable for practice and leading to nursing actions? Two examples of well known instruments and different kinds of their utilization in nursing are discussed. Next, the instruments have to be questioned as "bodies with numbers". Studies on reliability and validity have to be as carefully evaluated as other empirical research. The sample, the suitability of agreement indicators (interraterreliability), kind and reason of tests have to be questioned. The same has to be done with tests of validity which comprise an even greater challenge. Methodological studies about these questions are missing; guidelines for test user qualifications need to be developed.
Instrument Modeling and Synthesis
NASA Astrophysics Data System (ADS)
Horner, Andrew B.; Beauchamp, James W.
During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.
Mayo, Ann M
2015-01-01
It is important for CNSs and other APNs to consider the reliability and validity of instruments chosen for clinical practice, evidence-based practice projects, or research studies. Psychometric testing uses specific research methods to evaluate the amount of error associated with any particular instrument. Reliability estimates explain more about how well the instrument is designed, whereas validity estimates explain more about scores that are produced by the instrument. An instrument may be architecturally sound overall (reliable), but the same instrument may not be valid. For example, if a specific group does not understand certain well-constructed items, then the instrument does not produce valid scores when used with that group. Many instrument developers may conduct reliability testing only once, yet continue validity testing in different populations over many years. All CNSs should be advocating for the use of reliable instruments that produce valid results. Clinical nurse specialists may find themselves in situations where reliability and validity estimates for some instruments that are being utilized are unknown. In such cases, CNSs should engage key stakeholders to sponsor nursing researchers to pursue this most important work.
NASA Astrophysics Data System (ADS)
Eakin, Caroline M.; Rychert, Catherine A.; Harmon, Nicholas
2018-02-01
Mantle anisotropy beneath mid-ocean ridges and oceanic transforms is key to our understanding of seafloor spreading and underlying dynamics of divergent plate boundaries. Observations are sparse, however, given the remoteness of the oceans and the difficulties of seismic instrumentation. To overcome this, we utilize the global distribution of seismicity along transform faults to measure shear wave splitting of over 550 direct S phases recorded at 56 carefully selected seismic stations worldwide. Applying this source-side splitting technique allows for characterization of the upper mantle seismic anisotropy, and therefore the pattern of mantle flow, directly beneath seismically active transform faults. The majority of the results (60%) return nulls (no splitting), while the non-null measurements display clear azimuthal dependency. This is best simply explained by anisotropy with a near vertical symmetry axis, consistent with mantle upwelling beneath oceanic transforms as suggested by numerical models. It appears therefore that the long-term stability of seafloor spreading may be associated with widespread mantle upwelling beneath the transforms creating warm and weak faults that localize strain to the plate boundary.
Trident: A Universal Tool for Generating Synthetic Absorption Spectra from Astrophysical Simulations
NASA Astrophysics Data System (ADS)
Hummels, Cameron B.; Smith, Britton D.; Silvia, Devin W.
2017-09-01
Hydrodynamical simulations are increasingly able to accurately model physical systems on stellar, galactic, and cosmological scales; however, the utility of these simulations is often limited by our ability to directly compare them with the data sets produced by observers: spectra, photometry, etc. To address this problem, we have created trident, a Python-based open-source tool for post-processing hydrodynamical simulations to produce synthetic absorption spectra and related data. trident can (I) create absorption-line spectra for any trajectory through a simulated data set mimicking both background quasar and down-the-barrel configurations; (II) reproduce the spectral characteristics of common instruments like the Cosmic Origins Spectrograph; (III) operate across the ultraviolet, optical, and infrared using customizable absorption-line lists; (IV) trace simulated physical structures directly to spectral features; (v) approximate the presence of ion species absent from the simulation outputs; (VI) generate column density maps for any ion; and (vii) provide support for all major astrophysical hydrodynamical codes. trident was originally developed to aid in the interpretation of observations of the circumgalactic medium and intergalactic medium, but it remains a general tool applicable in other contexts.
NASA Astrophysics Data System (ADS)
Mihara, T.; Maxi Team
2010-12-01
Gas Slit Camera (GSC) is the instrument in the MAXI mission. The GSC utilizes twelve large area proportional counters (PC), a slit and slats collimator. The energy range is 2-30 keV. The GSC has two FOVs of 160 x 3 degrees. One is toward forward direction of ISS and the other is the zenithal direction. Two arches of FOV scans the sky in every 92 minutes with ISS rotation. The slats collimator makes the narrow arc FOV, and the one-dimensional position-resolution of the PC resolves the X-ray sources within the FOV. Thus the position resolution is determined by the slats collimator and a combination of the slit and the position resolution of the detector. These make the point spread function of 1.5 x 1.5 degrees. The background is 1.2 × 10^-4 c/s/cm2 /keV, which is almost the same level with Ginga/LAC. The 5-sigma sensitivity is 15 mCrab/day, which is improved to with the sqrt (t) law. It will reach the 5 sigma confusion limit of 0.5 mCrab in 900 days, if the particle-background estimation is accurate enough.
NASA Astrophysics Data System (ADS)
Geiss, Alexander; Marksteiner, Uwe; Lux, Oliver; Lemmerz, Christian; Reitebuch, Oliver; Kanitz, Thomas; Straume-Lindner, Anne Grete
2018-04-01
By the end of 2017, the European Space Agency (ESA) will launch the Atmospheric laser Doppler instrument (ALADIN), a direct detection Doppler wind lidar operating at 355 nm. An important tool for the validation and optimization of ALADIN's hardware and data processors for wind retrievals with real atmospheric signals is the ALADIN airborne demonstrator A2D. In order to be able to validate and test aerosol retrieval algorithms from ALADIN, an algorithm for the retrieval of atmospheric backscatter and extinction profiles from A2D is necessary. The A2D is utilizing a direct detection scheme by using a dual Fabry-Pérot interferometer to measure molecular Rayleigh signals and a Fizeau interferometer to measure aerosol Mie returns. Signals are captured by accumulation charge coupled devices (ACCD). These specifications make different steps in the signal preprocessing necessary. In this paper, the required steps to retrieve aerosol optical products, i. e. particle backscatter coefficient βp, particle extinction coefficient αp and lidar ratio Sp from A2D raw signals are described.
Nahan, Keaton S; Alvarez, Noe; Shanov, Vesselin; Vonderheide, Anne
2017-11-01
Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R 2 ) of three target PAHs with phenanthrene internal standard. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Nahan, Keaton S.; Alvarez, Noe; Shanov, Vesselin; Vonderheide, Anne
2017-09-01
Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R2) of three target PAHs with phenanthrene internal standard. [Figure not available: see fulltext.
TFTR CAMAC systems and components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rauch, W.A.; Bergin, W.; Sichta, P.
1987-08-01
Princeton's tokamak fusion test reactor (TFTR) utilizes Computer Automated Measurement and Control (CAMAC) to provide instrumentation for real and quasi real time control, monitoring, and data acquisition systems. This paper describes and discusses the complement of CAMAC hardware systems and components that comprise the interface for tokamak control and measurement instrumentation, and communication with the central instrumentation control and data acquisition (CICADA) system. It also discusses CAMAC reliability and calibration, types of modules used, a summary of data acquisition and control points, and various diagnostic maintenance tools used to support and troubleshoot typical CAMAC systems on TFTR.
Chronic swine instrumentation techniques utilizing the GOR-REX peritoneal catheter
NASA Astrophysics Data System (ADS)
Gray, C. C.; White, F. C.; Crisman, R. P.; Wisniewski, J.; McKirnan, D.
1985-05-01
The GORE-TEX peritoneal catheter interface is an effective skin interface device for many types of instrumentation in the swine. When properly utilized, the interface allows the development of a stable and effective biological seal which will reduce or eliminate sinus tract formation and resultant systemic infection. The interface is suitable for running any wire or catheter (up to about 2.5mm diameter) through the integument of the animal, thus increasing the possibilities for chronic instrumentation while maintaining a healthy animal. The lack of evidence of any growth phenomenon acting to extrude the interface segment, similar to that observed using other synthetic materials, and the superior biological seal which the interface develops, may allow many chronic studies which were previously not feasible. Using special catheter adapter stubs and an intermittent infusion plug, a sterile, sealed catheter system has decreased the possibilities for introducing pathogens while allowing ready access to the blood stream. Detailed descriptions of surgical implantation techniques and catheter set up and maintenance techniques are included.
Preliminary design trade-offs for a multi-mission stored cryogen cooler
NASA Technical Reports Server (NTRS)
Sherman, A.
1978-01-01
Preliminary design studies were performed for a multi-mission solid cryogen cooler having a wide range of application for both the shuttle sortie and free flyer missions. This multi-mission cooler (MMC) is designed to be utilized with various solid cryogens to meet a wide range of instrument cooling from 10 K (with solid hydrogen) to 90 K. The baseline cooler utilizes two stages of solid cryogen and incorporates an optional, higher temperature third stage which is cooled by either a passive radiator or a thermoelectric cooler. The MMC has an interface which can accommodate a wide variety of instrument configurations. A shrink fit adapter is incorporated which allows a drop-in instrument integration. The baseline design provides cooling of approximately 1 watt over a 60 to 100 K temperature range and about 0.5 watts from 15 to 60 K for a one year lifetime. For low cooling loads and with use of the optional radiator shield, cooling lifetimes as great as 8 years are predicted.
Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling
NASA Technical Reports Server (NTRS)
Nast, T. C.
1983-01-01
The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.
Mediodorsal thalamus hypofunction impairs flexible goal-directed behavior.
Parnaudeau, Sébastien; Taylor, Kathleen; Bolkan, Scott S; Ward, Ryan D; Balsam, Peter D; Kellendonk, Christoph
2015-03-01
Cognitive inflexibility is a core symptom of several mental disorders including schizophrenia. Brain imaging studies in schizophrenia patients performing cognitive tasks have reported decreased activation of the mediodorsal thalamus (MD). Using a pharmacogenetic approach to model MD hypofunction, we recently showed that decreasing MD activity impairs reversal learning in mice. While this demonstrates causality between MD hypofunction and cognitive inflexibility, questions remain about the elementary cognitive processes that account for the deficit. Using the Designer Receptors Exclusively Activated by Designer Drugs system, we reversibly decreased MD activity during behavioral tasks assessing elementary cognitive processes inherent to flexible goal-directed behaviors, including extinction, contingency degradation, outcome devaluation, and Pavlovian-to-instrumental transfer (n = 134 mice). While MD hypofunction impaired reversal learning, it did not affect the ability to learn about nonrewarded cues or the ability to modulate action selection based on the outcome value. In contrast, decreasing MD activity delayed the ability to adapt to changes in the contingency between actions and their outcomes. In addition, while Pavlovian learning was not affected by MD hypofunction, decreasing MD activity during Pavlovian learning impaired the ability of conditioned stimuli to modulate instrumental behavior. Mediodorsal thalamus hypofunction causes cognitive inflexibility reflected by an impaired ability to adapt actions when their consequences change. Furthermore, it alters the encoding of environmental stimuli so that they cannot be properly utilized to guide behavior. Modulating MD activity could be a potential therapeutic strategy for promoting adaptive behavior in human subjects with cognitive inflexibility. Copyright © 2015 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Alcohol demand and risk preference
Dave, Dhaval; Saffer, Henry
2008-01-01
Both economists and psychologists have studied the concept of risk preference. Economists categorize individuals as more or less risk-tolerant based on the marginal utility of income. Psychologists categorize individuals' propensity towards risk based on harm avoidance, novelty seeking and reward dependence traits. The two concepts of risk are related, although the instruments used for empirical measurement are quite different. Psychologists have found risk preference to be an important determinant of alcohol consumption; however economists have not included risk preference in studies of alcohol demand. This is the first study to examine the effect of risk preference on alcohol consumption in the context of a demand function. The specifications employ multiple waves from the Panel Study of Income Dynamics (PSID) and the Health and Retirement Study (HRS), which permit the estimation of age-specific models based on nationally representative samples. Both of these data sets include a unique and consistent survey instrument designed to directly measure risk preference in accordance with the economist's definition. This study estimates the direct impact of risk preference on alcohol demand and also explores how risk preference affects the price elasticity of demand. The empirical results indicate that risk preference has a significant negative effect on alcohol consumption, with the prevalence and consumption among risk-tolerant individuals being 6–8% higher. Furthermore, the tax elasticity is similar across both risk-averse and risk-tolerant individuals. This suggests that tax policies are as equally effective in deterring alcohol consumption among those who have a higher versus a lower propensity for alcohol use. PMID:19956353
Biogeochemical Proxies in Scleractinian Corals used to Reconstruct Ocean Circulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guilderson, T.P.; Kashgarian, M.; Schrag, D.P.
We utilize monthly {sup 14}C data derived from coral archives in conjunction with ocean circulation models to address two questions: (1) how does the shallow circulation of the tropical Pacific vary on seasonal to decadal time scales and (2) which dynamic processes determine the mean vertical structure of the equatorial Pacific thermocline. Our results directly impact the understanding of global climate events such as the El Nino-Southern Oscillation (ENSO). To study changes in ocean circulation and water mass distribution involved in the genesis and evolution of ENSO and decadal climate variability, it is necessary to have records of climate variablesmore » several decades in length. Continuous instrumental records are limited because technology for continuous monitoring of ocean currents has only recently been available, and ships of opportunity archives such as COADS contain large spatial and temporal biases. In addition, temperature and salinity in surface waters are not conservative and thus can not be independently relied upon to trace water masses, reducing the utility of historical observations. Radiocarbon ({sup 14}C) in sea water is a quasi-conservative water mass tracer and is incorporated into coral skeletal material, thus coral {sup 14}C records can be used to reconstruct changes in shallow circulation that would be difficult to characterize using instrumental data. High resolution {Delta}{sup 14}C timeseries such as these, provide a powerful constraint on the rate of surface ocean mixing and hold great promise to augment onetime surveys such as GEOSECS and WOCE. These data not only provide fundamental information about the shallow circulation of the Pacific, but can be used as a benchmark for the next generation of high resolution ocean models used in prognosticating climate change.« less
Biogeochemical Proxies in Scleractinian Corals used to Reconstruct Ocean Circulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guilderson, T P; Kashgarian, M; Schrag, D P
2001-02-23
We utilize monthly {sup 14}C data derived from coral archives in conjunction with ocean circulation models to address two questions: (1) how does the shallow circulation of the tropical Pacific vary on seasonal to decadal time scales and (2) which dynamic processes determine the mean vertical structure of the equatorial Pacific thermocline. Our results directly impact the understanding of global climate events such as the El Nino-Southern Oscillation (ENSO). To study changes in ocean circulation and water mass distribution involved in the genesis and evolution of ENSO and decadal climate variability, it is necessary to have records of climate variablesmore » several decades in length. Continuous instrumental records are limited because technology for continuous monitoring of ocean currents has only recently been available, and ships of opportunity archives such as COADS contain large spatial and temporal biases. In addition, temperature and salinity in surface waters are not conservative and thus can not be independently relied upon to trace water masses, reducing the utility of historical observations. Radiocarbon ({sup 14}C) in sea water is a quasi-conservative water mass tracer and is incorporated into coral skeletal material, thus coral {sup 14}C records can be used to reconstruct changes in shallow circulation that would be difficult to characterize using instrumental data. High resolution {Delta}{sup 14}C timeseries such as these, provide a powerful constraint on the rate of surface ocean mixing and hold great promise to augment onetime surveys such as GEOSECS and WOCE. These data not only provide fundamental information about the shallow circulation of the Pacific, but can be used as a benchmark for the next generation of high resolution ocean models used in prognosticating climate change.« less
Simons, Joke; Dewitte, Siegfried; Lens, Willy
2004-09-01
Two theories in the field of motivation and achievement, namely the future time perspective theory and goal theory, result in conflicting recommendations for enhancing students' motivation, because of their differential emphasis on the task at hand and on the future consequences of a task. We will present a framework consisting of four types of instrumentality that combines both perspectives. The implications of those different types for goal orientation, motivation, cognitive strategies, study habits and performance are investigated. Participants were a group of 184 first-year nurse students with ages ranging from 18 to 45 years. Questionnaires were administered that measured instrumentality, goal orientation, motivation, deep and surface level learning strategies, study habits, and a manipulation check. At the end of the year, exam scores were collected. The results showed that different types of instrumentality are related differently to the motivational, cognitive and achievement measures. Being internally regulated and perceiving the utility of the courses resulted both in a more adaptive goal orientation and higher intrinsic motivation, which led to the use of more adaptive cognitive strategies and to better study habits, which ultimately enhanced performance. Linking performance to extrinsic rewards and not seeing the utility of the course for the future yielded the opposite pattern. Type of instrumentality has indeed a differential influence on motivational, cognitive, and behavioural variables.
A laboratory comparison of evacuation devices on aerosol reduction.
Jacks, Mary E
2002-01-01
Aerosols are defined as airborne particles that range in size from 0.5 to 10 microns (micron). They are produced during ultrasonic instrumentation, but they can be reduced. Irrigant solutions, which produce the therapeutic effects of lavage, also combine with blood, saliva, and bacteria to produce potentially harmful airborne particulates. The American Dental Association (ADA) and the Centers for Disease Control and Prevention (CDC) recommend utilization of high volume evacuation, rubber dam, and patient positioning for aerosol control. But for the non-assisted dental hygienist, these recommendations are difficult to implement. This study was designed to compare the concentration of airborne particulates from ultrasonic scaling, utilizing three different methods of evacuation. In a laboratory setting, ultrasonic airborne particulates were generated utilizing a 25,000 cps magnetostrictive ultrasonic scaling instrument. Three evacuation devises were compared for effectiveness: a standard saliva ejector intraorally positioned; and two extraorally positioned, hands-free high-volume evacuation (HFHVE) techniques. One of these devices had a standard attachment, and, the other had a funnel-shaped attachment. Measurement of airborne particles was performed with a DataRAM Real-Time Aerosol Monitor. This study (N = 21) found a significant reduction in the number of airborne particulates with either form of extraoral HFHVE attachment in place. Standard attachments and funnel-shaped attachments to HFHVE resulted in reduction of particulates by 90.8% and 89.7%, respectively, when compared to the intraorally positioned standard saliva ejector. Utilizing either form of HFHVE during ultrasonic instrumentation significantly reduced the number of aerosolized particulates that reached the breathing space of the client and clinician. This lends support for the ADA and CDC recommendation that HVE be used during aerosol producing procedures. Currently, no preventive measure is 100% effective; therefore, clinicians are encouraged to use additional methods to minimize the number of airborne particulates produced during intraoral instrumentation.
ERIC Educational Resources Information Center
Rosenblatt, Rebecca; Heckler, Andrew F.
2011-01-01
We developed an instrument to systematically investigate student conceptual understanding of the relationships between the directions of net force, velocity, and acceleration in one dimension and report on data collected on the final version of the instrument from over 650 students. Unlike previous work, we simultaneously studied all six possible…
ERIC Educational Resources Information Center
Morris, Harold J.
In an effort to assess community college teachers' level of acceptance of and willingness to implement administrative directives, a survey instrument and personal data sheet were delivered to 130 public community college teachers in Mississippi. A modified Zones of Indifference instrument was used to assess respondents' attitudes towards 71…
Wind-instrument reflection function measurements in the time domain.
Keefe, D H
1996-04-01
Theoretical and computational analyses of wind-instrument sound production in the time domain have emerged as useful tools for understanding musical instrument acoustics, yet there exist few experimental measurements of the air-column response directly in the time domain. A new experimental, time-domain technique is proposed to measure the reflection function response of woodwind and brass-instrument air columns. This response is defined at the location of sound regeneration in the mouthpiece or double reed. A probe assembly comprised of an acoustic source and microphone is inserted directly into the air column entryway using a foam plug to ensure a leak-free fit. An initial calibration phase involves measurements on a single cylindrical tube of known dimensions. Measurements are presented on an alto saxophone and euphonium. The technique has promise for testing any musical instrument air columns using a single probe assembly and foam plugs over a range of diameters typical of air-column entryways.