Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas
2016-11-01
This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time monitors is convenient for measurement of airborne PM at short time scales, the accuracy of those monitors depends on a particular instrument. Bias correction factors identified in this paper could provide guidance for other studies using direct-reading instruments to measure PM concentrations.
Direct force-measuring transducer used in blood pressure research
NASA Technical Reports Server (NTRS)
Eige, J. J.; Newgard, P. M.; Pressman, G. L.
1965-01-01
Direct force measuring transducer acts as an arterial tonometer, gives a direct readout to instrumentation, and is unaffected by ambient noise. It uses a semiconductor strain gage which is deflected by pressure pulses in the artery. The deflection changes the resistance of the gage and alters the voltage reading on the associated instrumentation.
47 CFR 2.1511 - Measurements of radiated emissions.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) General set-up instructions. Measurements of radiated electromagnetic emissions (EME) are to be performed... meters in both vertical and horizontal polarization. Record the highest receiver reading in dBm as the... receiver reading in dBm and the instrument settings, antenna height and direction for maximum radiation...
47 CFR 2.1511 - Measurements of radiated emissions.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) General set-up instructions. Measurements of radiated electromagnetic emissions (EME) are to be performed... receiver reading in dBm and the instrument settings, antenna height and direction for maximum radiation...
The Mirror Caliper, A New Optical Dendrometer
Joe P. McClure
1969-01-01
Five years of field tests have proved that the mirror caliper--a hand-held, nonmagnifying, optical caliper--is a practical instrument for use in taking upper-stem measurements (diameter outside bark) at any point on a standing tree. Parallel lines-of-sight produce direct-reading measurements within a range of 3.5 to 16.0 inches. Accurate readings can be taken in...
Hillman, D J; Green, S W
1994-10-01
The Weldon Spring Site Remedial Action Project (WSSRAP) began remediation of its chemical plant buildings in June 1992. The chemical plant was used by the Atomic Energy Commission in the 1950's and 1960's to process uranium ore and natural thorium. Many remaining equipment surfaces were highly contaminated with uranium and thorium product residues, which are relatively weak gamma emitters, but are strong beta emitters that deposit the majority of their energy within the first centimeter of tissue. An essential part of the remediation, therefore, is to control the dose to the skin, extremities, and the lens of the eye from the broad range of betas emitted by uranium and thorium decay series radionuclides. The WSSRAP planned to quantitatively record the dose to the skin, extremities, and the lens of the eye, when warranted, through selection and use of appropriate passive dosimeters. That would not, however, constitute control. A direct-reading instrument was needed that could be used by field technicians to anticipate and prevent work methods and situations that would otherwise result in the unnecessary commitment of dose. However, the interpretation of real-time instrument readings produced by a broad spectrum of beta energies is typically challenging at best, particularly when the shallow dose rate and the lens dose rate are both of interest. The purpose of this effort was, therefore, to (1) select a direct-reading instrument for use in the buildings that could be used to provide rule-of-thumb action levels for field technicians, which, if exceeded, would warrant worker protective measures; (2) determine the approximate conversions between the instrument readings and the shallow (including extremity) dose rate and lens of the eye dose rate; and (3) specify protective measures and dosimetry for the lens of the eye, if warranted. Methods described in the literature are used to estimate action levels for direct instrument readings and to demonstrate that lens dosimetry and special protective measures for the lens of the eye are not necessary at the WSSRAP.
Vo, Evanly; Zhuang, Ziqing; Birch, Eileen; Birch, Quinn
2016-01-01
The aim of this study was to apply a direct-reading aerosol instrument method and an elemental carbon (EC) analysis method to measure the mass-based penetration of single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) through elastomeric half-mask respirators (EHRs) and filtering facepiece respirators (FFRs). For the direct-reading aerosol instrument method, two scanning mobility particle sizer/aerodynamic particle sizer systems were used to simultaneously determine the upstream (outside respirator) and downstream (inside respirator) test aerosols. For the EC analysis method, upstream and downstream CNTs were collected on filter cassettes and then analyzed using a thermal-optical technique. CNT mass penetrations were found in both methods to be within the associated efficiency requirements for each type and class of the respirator models that were tested. Generally, the penetrations of SWCNTs and MWCNTs had a similar trend with penetration being the highest for the N95 EHRs, followed by N95 FFRs, P100 EHRs, and P100 FFRs. This trend held true for both methods; however, the CNT penetration determined by the direct-reading aerosol instrument method (0.009-1.09% for SWCNTs and 0.005-0.21% for MWCNTs) was greater relative to the penetration values found through EC analysis method (0.007-0.69% for SWCNTs and 0.004-0.13% for MWCNTs). The results of this study illustrate considerations for how the methods can be used to evaluate penetration of morphologically complex materials through FFRs and EHRs.
Mihandoost, Zeinab; Elias, Habibah
2011-01-01
The current research tested the differences in reading attitude and reading comprehension in the dyslexic students between the control group and the experimental group following the Barton intervention program. Dyslexia screening instrument and reading text were employed in order to identify dyslexic students. The population of the study included 138 dyslexic students studying in schools in Ilam, Iran. From this population, 64 students were randomly selected and assigned to an experimental group as well as a control group. The experimental group was taught for 36 sessions, using the Barton's method at two levels, and ten lessons were provided to improve the reading skill. The reading comprehension and reading attitude instruments were employed for the measurement of the attitude and comprehension before and after the intervention program. The analysis of covariance showed a significant difference between the control group and the experimental group following the Barton intervention program. This study showed that dyslexic students learned to read, and a more direct instruction related to decoding could influence their progress more than the general exposure to education.
NASA Astrophysics Data System (ADS)
Bau, Sébastien; Witschger, Olivier; Gensdarmes, François; Thomas, Dominique
2009-05-01
An increasing number of experimental and theoretical studies focus on airborne nanoparticles (NP) in relation with many aspects of risk assessment to move forward our understanding of the hazards, the actual exposures in the workplace, and the limits of engineering controls and personal protective equipment with regard to NP. As a consequence, generating airborne NP with controlled properties constitutes an important challenge. In parallel, toxicological studies have been carried out, and most of them support the concept that surface-area could be a relevant metric for characterizing exposure to airborne NP [1]. To provide NP surface-area concentration measurements, some direct-reading instruments have been designed, based on attachment rate of unipolar ions to NP by diffusion. However, very few information is available concerning the performances of these instruments and the parameters that could affect their responses. In this context, our work aims at characterizing the actual available instruments providing airborne NP surface-area concentration. The instruments (a- LQ1-DC, Matter Engineering; b-AeroTrak™ 9000, TSI; c- NSAM, TSI model 3550;) are thought to be relevant for further workplace exposure characterization and monitoring. To achieve our work, an experimental facility (named CAIMAN) was specially designed, built and characterized.
Mihandoost, Zeinab; Elias, Habibah
2011-01-01
Objective: The current research tested the differences in reading attitude and reading comprehension in the dyslexic students between the control group and the experimental group following the Barton intervention program. Methods: Dyslexia screening instrument and reading text were employed in order to identify dyslexic students. The population of the study included 138 dyslexic students studying in schools in Ilam, Iran. From this population, 64 students were randomly selected and assigned to an experimental group as well as a control group. The experimental group was taught for 36 sessions, using the Barton’s method at two levels, and ten lessons were provided to improve the reading skill. The reading comprehension and reading attitude instruments were employed for the measurement of the attitude and comprehension before and after the intervention program. Results: The analysis of covariance showed a significant difference between the control group and the experimental group following the Barton intervention program. Conclusion: This study showed that dyslexic students learned to read, and a more direct instruction related to decoding could influence their progress more than the general exposure to education. PMID:24644446
Indirect Field Measurement of Wine-Grape Vineyard Canopy Leaf Area Index
NASA Technical Reports Server (NTRS)
Johnson, Lee F.; Pierce, Lars L.; Skiles, J. W. (Technical Monitor)
2002-01-01
Leaf area index (LAI) indirect measurements were made at 12 study plots in California's Napa Valley commercial wine-grape vineyards with a LI-COR LI-2000 Plant Canopy Analyzer (PCA). The plots encompassed different trellis systems, biological varieties, and planting densities. LAI ranged from 0.5 - 2.25 sq m leaf area/ sq m ground area according to direct (defoliation) measurements. Indirect LAI reported by the PCA was significantly related to direct LAI (r(exp 2) = 0.78, p less than 001). However, the PCA tended to underestimate direct LAI by about a factor of two. Narrowing the instrument's conical field of view from 148 deg to 56 deg served to increase readings by approximately 30%. The PCA offers a convenient way to discern relative differences in vineyard canopy density. Calibration by direct measurement (defoliation) is recommended in cases where absolute LAI is desired. Calibration equations provided herein may be inverted to retrieve actual vineyard LAI from PCA readings.
Optical radiation measurements and instrumentation.
Andersen, F A; Landry, R J
1981-07-01
Accurate measurement of optical radiation is required when sources of optical radiation are used in biological research. Such measurement of broad-band noncoherent optical radiations usually must be performed by a highly trained specialist using sophisticated, complex, and expensive instruments. Presentation of the results of such measurement requires correct use of quantities and units with which many biological researchers are unfamiliar. The measurement process, quantities, units, measurement systems and instruments, and uncertainties associated with optical radiation measurements are reviewed in this paper. A conventional technique for evaluating the potential hazards associated with broad-band sources of optical radiation and a spectroradiometer developed to measure spectral quantities is described. A new prototype ultraviolet radiation hazard monitor which has recently been developed is also presented. This new instrument utilizes a spectrograph and a spectral weighting mechanical mask and provides a direct reading of the effective irradiance for wavelengths less than 315 nm.
A Field Assessment of a Prototype Meter for Measuring the Wet-Bulb Globe-Thermometer Index
Walters, J. D.
1968-01-01
A prototype electronic instrument for the direct measurement of the wet-bulb globe-thermometer index is described. An assessment is made of its accuracy, as compared with W.B.G.T. indices calculated from conventional thermometric data, and a comparison is made between W.B.G.T. values read from the meter and effective or corrected effective temperatures derived from separate thermometric and air velocity recording instruments in the same climates. The instrument proved to be reliable and accurate over a wide range of climates and is a useful self-contained device for use in habitability surveys and similar investigations. Images PMID:5663429
Uterine caliper and depth gauge
King, Loyd L.; Wheeler, Robert G.; Fish, Thomas M.
1977-01-01
A uterine caliper and sound consisting of an elongated body having outwardly biased resilient caliper wings and a spring-loaded slidable cervical stop. A slide on the body is operatively connected to the wings by a monofilament and operates with respect to a first scale on the body as a width indicator. A rod extending longitudinally on the body is connected to the cervical stop and cooperates with a second scale on the body as a depth indicator. The instrument can be positioned to measure the distance from the outer cervical ostium to the fundus, as read on said second scale. The wings may be allowed to open by moving the slide, and when the wings engage the utero-tubal junctions, the width may be read on said first scale. By adjustment of the caliper wings the instrument may be retracted until the resistance of the inner ostium of the cervix is felt, enabling the length of the cervical canal to be read directly by the position of the longitudinal indicator rod with respect to said second scale. The instrument may be employed to measure the width of the uterine cavity at any position between the inner ostium of the cervix and the fundus.
A Direct Reading Thermometer Based on a Silicon Diode.
ERIC Educational Resources Information Center
Kirkup, L.; Tonthat, C.
1998-01-01
Describes a simple circuit based on an inexpensive quad operational amplifier that permits a direct-reading temperature instrument to be constructed using silicon diodes. Encourages the use of this equipment in introductory thermal experiments. (DDR)
ERIC Educational Resources Information Center
Williams, Lunetta M.; Hall, Katrina W.; Hedrick, Wanda B.; Lamkin, Marcia; Abendroth, Jennifer
2013-01-01
The purpose of the present study was to develop an instrument to measure reading during in-school independent reading (ISIR). Procedures to establish validity and reliability of the instrument included videotaping and observing students during ISIR, gathering feedback from literacy experts, establishing interrater reliability, crosschecking…
Direct-reading inductance meter
NASA Technical Reports Server (NTRS)
Kolbly, R. B.
1977-01-01
Meter indicates from 30 nH to 3 micro H. Reference inductor of 15 micro H is made by winding 50 turns of Number 26 Formvar wire on Micrometal type 50-2 (or equivalent) core. Circuit eliminates requirement for complex instrument compensation prior to taking coil inductance measurement and thus is as easy to operate as common ohmmeter.
Early reading performance: a comparison of teacher-based and test-based assessments.
Kenny, D T; Chekaluk, E
1993-04-01
An unresolved question in early screening is whether test-based or teacher-based assessments should form the basis of the classification of children at risk of educational failure. Available structured teacher rating scales are lacking in predictive validity, and teacher predictions of students likely to experience reading difficulties have yielded disappointing true positive rates, with teachers failing to identify the majority of severely disabled readers. For this study, three educational screening instruments were developed: (a) a single teacher rating, categorizing children into three levels of reading ability (advanced, average, poor); (b) a 15-item teacher questionnaire designed to measure students' cognitive and language ability, attentional and behavioral characteristics, and academic performance; and (c) a battery of language and reading tests that are predictive of, or correlate with, reading failure. The concurrent validity of each instrument was assessed in a sample of 312 Australian schoolchildren from kindergarten, Year 1, and Year 2. Students were assessed at the end of the 1989 school year after having completed 1, 2, or 3 years of schooling. The results suggest that the nature of the skills required for success in reading changes in the first 3 years of schooling. Both teachers and tests concur more closely as children progress through the elementary years and as the risk behavior (reading) becomes more accessible to direct measurement. Carefully focused teacher rating scales may be a cost-effective means of identifying children at risk of reading failure. Improved teacher rating scales should be developed and used to assist in the early screening process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.
We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less
Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.; ...
2015-01-27
We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, P.
The majority of general-purpose low-temperature handheld radiation thermometers are severely affected by the size-of-source effect (SSE). Calibration of these instruments is pointless unless the SSE is accounted for in the calibration process. Traditional SSE measurement techniques, however, are costly and time consuming, and because the instruments are direct-reading in temperature, traditional SSE results are not easily interpretable, particularly by the general user. This paper describes a simplified method for measuring the SSE, suitable for second-tier calibration laboratories and requiring no additional equipment, and proposes a means of reporting SSE results on a calibration certificate that should be easily understood bymore » the non-specialist user.« less
Compact Instruments Measure Helium-Leak Rates
NASA Technical Reports Server (NTRS)
Stout, Stephen; Immer, Christopher
2003-01-01
Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.
[Portable multi-purpose device for monitoring of physiological informations].
Tamura, T; Togawa, T
1983-05-01
Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.
29 CFR 1910.146 - Permit-required confined spaces.
Code of Federal Regulations, 2011 CFR
2011-07-01
... danger posed by the permit spaces. Note: A sign reading “DANGER—PERMIT-REQUIRED CONFINED SPACE, DO NOT... tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors... dependent and will not provide reliable readings in an oxygen deficient atmosphere. Combustible gasses are...
Evaluation of an aerosol photometer for monitoring welding fume levels in a shipyard.
Glinsmann, P W; Rosenthal, F S
1985-07-01
A direct reading aerosol photometer (Sibata P-5 Digital Dust Indicator) was used to assess fume levels from welding and burning operations in a shipyard. The photometer was calibrated with gravimetric analysis of filter samples collected simultaneously with instrument readings. A six-fold difference between calibration factors for personal and area samples was found. This difference can be explained by expected changes in particle size distributions in welding fume. Monitoring of various work situations was performed in order to assess the value of the photometer for the measurement of fume. Measurements categorized by enclosure of space and quality of ventilation indicated the presence of high fume levels in semi-enclosed and enclosed spaces. The build up of welding fume in an enclosed space occurred over several minutes after the arc was struck. Decay likewise required several minutes. During welding, wide fluctuations of fume concentrations were found. Thus a single reading was not adequate to characterize average fume levels. Although this type of instrument is useful for locating areas with high fume levels and monitoring the effectiveness of ventilation, the uncertainty in calibration factors makes accurate determinations of fume levels difficult.
Peak exposures in aluminium potrooms: instrument development and field calibration.
Carter, Stephanie R; Seixas, Noah S; Thompson, Mary Lou; Yost, Michael G
2004-11-01
Aluminium smelter potrooms are unique in that workplace exposures to hydrogen fluoride (HF), sulfur dioxide (SO2), and particulate matter occur simultaneously for some tasks. The peak exposures to these contaminants are of increasing interest in discovering the etiology of respiratory health effects. While a variety of direct-reading instruments are available for sulfur dioxide and particulate matter, only a few exist for hydrogen fluoride. The sensors in these HF instruments have a cross-sensitivity to sulfur dioxide making it difficult to monitor HF in an environment that also contains SO2. To overcome this problem, we assessed the simultaneous use of two electrochemical instruments: one with a SO2 sensor that does not respond to HF and the second with a hydrogen fluoride sensor that responds to both HF and SO2 in a 1 : 1 ratio, termed 'total acid gas'. The difference in the response between the two instruments should indicate the HF concentration: [HF + SO2] minus SO2 equals HF. The performance characteristics of this sampling train were evaluated in the laboratory through the generation of both HF and SO2 with permeation tubes. The response and recovery times for the SO2 only instrument were acceptable (6 and 15 s, respectively), but the "total acid gas" instrument exhibited both slow response and slow recovery approaching three and six min. The association between the traditional integrated filter sampling method and the direct-reading instrument for SO2 is 0.80 (Spearman's rho). The use of the digital filter strengthens the association between the HF direct-reading instrument and the integrated samples from 0.41 to 0.68.
ERIC Educational Resources Information Center
Forster, Natalie; Souvignier, Elmar
2011-01-01
The purpose of this study was to examine the technical adequacy of a computer-based assessment instrument which is based on hierarchical models of text comprehension for monitoring student reading progress following the Curriculum-Based Measurement (CBM) approach. At intervals of two weeks, 120 third-grade students finished eight CBM tests. To…
What Do Diagnostic Reading Tests Really Diagnose?
ERIC Educational Resources Information Center
Winkley, Carol K.
A study was made of nine reading tests, including both group and individually-administered measures, which are claimed to be chiefly diagnostic. Instruments analyzed were the following: Silent Reading Diagnostic Tests (Bond, Balow, and Hoyt), Botel Reading Inventory, Durrell Analysis of Reading Difficulty, Gates-McKillop Reading Diagnostic Tests,…
Automatic calibration system for analog instruments based on DSP and CCD sensor
NASA Astrophysics Data System (ADS)
Lan, Jinhui; Wei, Xiangqin; Bai, Zhenlong
2008-12-01
Currently, the calibration work of analog measurement instruments is mainly completed by manual and there are many problems waiting for being solved. In this paper, an automatic calibration system (ACS) based on Digital Signal Processor (DSP) and Charge Coupled Device (CCD) sensor is developed and a real-time calibration algorithm is presented. In the ACS, TI DM643 DSP processes the data received by CCD sensor and the outcome is displayed on Liquid Crystal Display (LCD) screen. For the algorithm, pointer region is firstly extracted for improving calibration speed. And then a math model of the pointer is built to thin the pointer and determine the instrument's reading. Through numbers of experiments, the time of once reading is no more than 20 milliseconds while it needs several seconds if it is done manually. At the same time, the error of the instrument's reading satisfies the request of the instruments. It is proven that the automatic calibration system can effectively accomplish the calibration work of the analog measurement instruments.
Assessing Affective Constructs in Reading: A Mixed Methods Study
ERIC Educational Resources Information Center
Conradi, Kristin
2011-01-01
Research investigating affective dimensions in reading has long been plagued by vaguely defined constructs and, consequently, by an array of potentially problematic instruments designed to measure them. This mixed-methods study investigated the relationship among three popular group-administered instruments intended to tap affective constructs in…
Valencia-Sánchez, Jesús Salvador; Leyva-González, Félix Arturo; Viniegra-Velázquez, Leonardo
2007-01-01
To search the reach of educative strategy promoting the participation, to estimate the development of clinical aptitude and critical reading attaching the appropriate use of clinic research in cardiology residents. Prospective study. The instrument of clinical aptitude was constructed with five cases and 170 items and the instrument of critical reading was developed with five summaries of articles of clinical research in cardiology by 120 items. The strategy was performed with activities one a week during six months by two hours per class, in the period: March and September, 2005. Reading guides were delivered to the participants a week before that included a clinical case and clinic research of cardiology. During the activities in class we were promoting the participation and discussion. Both measuring instruments were performed in the first (initial measuring) and final session (final measuring). Non parametric test were used because the variable of the subjects were not normal distribution and the scale was ordinal. The reliability coefficient in both instruments with the Kuder-Richardson was 0.90 and 0.85 respectively. After educative strategy was observed a significant advance in the global calcifications, such as in critical reading and in clinical aptitude (p = 0.001 and 0.5 respectively). Analyzing in an independent manner the components of critical reading we found significant advancement in the indicators interpretation and judgment. In clinical aptitude we found significant progress in the indicators: the suitable use of paraclinics resources, the appropriate use of therapeutics measurement and iatropatogenic decisions for omission. The educative strategy promoting the participation, permitted to get a change in the clinical aptitude and critical reading attaching the appropriate use of sources of investigation in cardiology residents.
Finnie, Ramona K C; Felder, Tisha M; Linder, Suzanne Kneuper; Mullen, Patricia Dolan
2010-12-01
Consideration of categories related to reading comprehension--beyond reading level--is imperative to reach low literacy populations effectively. "Suitability" has been proposed as a term to encompass six categories of such factors: content, literacy demand graphics, layout/typography, learning stimulation, and cultural appropriateness. Our purpose was to describe instruments used to evaluate categories of suitability in cancer education materials in published reports and their findings. We searched databases and reference lists for evaluations of print and Web-based cancer education materials to identify and describe measures of these categories. Studies had to evaluate reading level and at least one category of suitability. Eleven studies met our criteria. Seven studies reported inter-rater reliability. Cultural appropriateness was most often assessed; four instruments assessed only surface aspects of cultural appropriateness. Only two of seven instruments used, the suitability assessment of materials (SAM) and the comprehensibility assessment of materials (SAM + CAM), were described as having any evidence of validity. Studies using Simplified Measure of Goobledygook (SMOG) and Fry reported higher average reading level scores than those using Flesh-Kincaid. Most materials failed criteria for reading level and cultural appropriateness. We recommend more emphasis on the categories of suitability for those developing cancer education materials and more study of these categories and reliability and validity testing of instruments.
ERIC Educational Resources Information Center
Nese, Joseph F. T.; Anderson, Daniel; Hoelscher, Kyle; Tindal, Gerald; Alonzo, Julie
2011-01-01
Curriculum-based measurement (CBM) is designed to measure students' academic status and growth so the effectiveness of instruction may be evaluated. In the most popular forms of reading CBM, the student's oral reading fluency is assessed. This behavior is difficult to sample in a computer-based format, a limitation that may be a function of the…
Arizona's Instrument to Measure Standards (AIMS DPA). Student Guide, Grade 8
ERIC Educational Resources Information Center
Arizona Department of Education, 2006
2006-01-01
Arizona's Instrument to Measure Standards (AIMS), a Standards-Based test, provides educators and the public with valuable information regarding the progress of Arizona's students toward mastering Arizona's reading, writing and mathematics Standards. This specific test, Arizona's Instrument to Measure Standards Dual Purpose Assessment (AIMS DPA) is…
Measuring Literary Reading Motivation: Questionnaires Design and Pilot Testing
ERIC Educational Resources Information Center
Chrysos, Michail
2017-01-01
This study aims to present the design and pilot testing procedures of the two specific self-report questionnaires were used to measure the two key aspects of reading motivation, self-efficacy and intrinsic motivation in the field of literary (narrative) reading, and the partial factors that jointly shape them. These instruments were outlined in…
Winds over the ocean as measured by the scatterometer on Seasat
NASA Technical Reports Server (NTRS)
Pierson, W. J.
1981-01-01
An analysis is presented of the relative accuracy of Seasat scatterometer measurements of the wind speeds and directions at 19.5 m altitude as compared to ground truth measurements taken by surface ships and instrumented buoys. Attention is given to the JASIN, QE II, and GOASEX surface data. The validity of 2-30 min averages taken from surface stations spread out over a wide area and serving as a basis for defining wind field averages over the 50 km resolution of SASS is examined. Satisfactory wind speeds were found to be available from SASS readings in the wind speed range 6-14 m/sec. The use of 25 SASS readings around a grid point was determined to reduce scatter to 0.25 m/sec when used in numerical weather prediction modeling. Improvements to the SASS techniques by the Seasat successor, NOSS, are discussed, and inclusion of momentum, heat, and water turbulent fluxes by NOSS is noted.
Kim, Jee Young; Magari, Shannon R; Herrick, Robert F; Smith, Thomas J; Christiani, David C
2004-11-01
Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed In this study, two such measurement methods were used simultaneously and compared. PM2.5 was sampled using a filter-based gravimetric sampling method and a direct-reading instrument, the TSI Inc. model 8520 DUSTTRAK aerosol monitor. Both sampling methods were used to determine the PM2.5 exposure in a group of boilermakers exposed to welding fumes and residual fuel oil ash. The geometric mean PM2.5 concentration was 0.30 mg/m3 (GSD 3.25) and 0.31 mg/m3 (GSD 2.90)from the DUSTTRAK and gravimetric method, respectively. The Spearman rank correlation coefficient for the gravimetric and DUSTTRAK PM2.5 concentrations was 0.68. Linear regression models indicated that log, DUSTTRAK PM2.5 concentrations significantly predicted loge gravimetric PM2.5 concentrations (p < 0.01). The association between log(e) DUSTTRAK and log, gravimetric PM2.5 concentrations was found to be modified by surrogate measures for seasonal variation and type of aerosol. PM2.5 measurements from the DUSTTRAK are well correlated and highly predictive of measurements from the gravimetric sampling method for the aerosols in these work environments. However, results from this study suggest that aerosol particle characteristics may affect the relationship between the gravimetric and DUSTTRAK PM2.5 measurements. Recalibration of the DUSTTRAK for the specific aerosol, as recommended by the manufacturer, may be necessary to produce valid measures of airborne particulate matter.
NASA Astrophysics Data System (ADS)
Hasözbek, Altug; Mathew, Kattathu; Wegener, Michael
2013-04-01
The total evaporation (TE) is a well-established analytical method for safeguards measurement of uranium and plutonium isotope-amount ratios using the thermal ionization mass spectrometry (TIMS). High accuracy and precision isotopic measurements find many applications in nuclear safeguards, for e.g. assay measurements using isotope dilution mass spectrometry. To achieve high accuracy and precision in TIMS measurements, mass dependent fractionation effects are minimized by either the measurement technique or changes in the hardware components that are used to control sample heating and evaporation process. At NBL, direct total evaporation (DTE) method on the modified MAT261 instrument, uses the data system to read the ion signal intensity and its difference from a pre-determined target intensity, is used to control the incremental step at which the evaporation filament is heated. The feedback and control is achieved by proprietary hardware from SPECTROMAT that uses an analog regulator in the filament power supply with direct feedback of the detector intensity. Compared to traditional TE method on this instrument, DTE provides better precision (relative standard deviation, expressed as a percent) and accuracy (relative difference, expressed as a percent) of 0.05 to 0.08 % for low enriched and high enriched NBL uranium certified reference materials.
NASA Technical Reports Server (NTRS)
Vasilyev, Y. M.; Lagunov, L. F.
1973-01-01
The schematic diagram of a noise measuring device is presented that uses pulse expansion modeling according to the peak or any other measured values, to obtain instrument readings at a very low noise error.
The Effect of Large Angles of Yaw on the Accuracy of Wing-Tip Yawmeters
NASA Technical Reports Server (NTRS)
Golden, Jacob
1942-01-01
The present method used by the NACA for the measurement of sideslip angles in flight involves the use of a device called the yawmeter. The operation of this instrument depends on the motion of a free-swinging vane which, mounted ahead of the wing tip, alines itself with the local wind direction. Because of the flow pattern about the airplane, the local wind direction at the yaw vane may be slightly different from the direction of the relative wind and the yaw-vane readings may be in error. This error is corrected by using half the difference between the readings of two vanes, one on each wing, for unyawed flight as a calibration constant. It is possible, however, that, because of the change in location of the vane with respect to the flow pattern at large angles of yaw, the constant obtained for unyawed flight may not apply. The present report covers power-off tests made in the free-flight tunnel to check the validity of this method.
Al Sayah, Fatima; Williams, Beverly; Johnson, Jeffrey A
2013-02-01
To identify instruments used to measure health literacy and numeracy in people with diabetes; evaluate their use, measurement scope, and properties; discuss their strengths and weaknesses; and propose the most useful, reliable, and applicable measure for use in research and practice settings. A systematic literature review was conducted to identify the instruments. Nutbeam's domains of health literacy and a diabetes health literacy skill set were used to evaluate the measurement scope of the identified instruments and to evaluate their applicability in people with diabetes. Fifty-six studies were included, from which one diabetes-specific (LAD) and eight generic measures of health literacy (REALM, REALM-R, TOFHLA, s-TOFHLA, NVS, 3-brief SQ, 3-level HL Scale, SILS) and one diabetes-specific (DNT) and two generic measures of numeracy (SNS, WRAT) were identified. These instruments were categorized into direct measures, that is, instruments that assess the performance of individuals on health literacy skills and indirect measures that rely on self-report of these skills. The most commonly used instruments measure selective domains of health literacy, focus mainly on reading and writing skills, and do not address other important skills such as verbal communication, health care system navigation, health-related decision making, and numeracy. The structure, mode, and length of administration and measurement properties were found to affect the applicability of these instruments in clinical and research settings. Indirect self- or clinician-administered measures are the most useful in both clinical and research settings. This review provides an evaluation of available health literacy measures and guidance to practitioners and researchers for selecting the appropriate measures for use in clinical settings and research applications.
ERIC Educational Resources Information Center
Kanfush, Philip Michael, III.
2010-01-01
The purpose of this study was to determine whether students with significant cognitive impairments make measurable gains in reading skills as measured by the Woodcock Reading Mastery Tests--Revised when taught using Direct Instruction reading programs. Additionally, the study explored teacher perceptions of the effectiveness of Direct Instruction…
Factorial and Construct Validity of a New Instrument for the Assessment of Reading Motivation
ERIC Educational Resources Information Center
Schiefele, Ulrich; Schaffner, Ellen
2016-01-01
Reading motivation has been defined consistently as a multidimensional construct. However, there is some disagreement regarding the number and nature of the dimensions of reading motivation. In particular, there is a lack of studies investigating the dimensional structure and measurement invariance (e.g., across gender) of reading motivation…
Reading Attitudes of Middle School Students: Results of a U.S. Survey
ERIC Educational Resources Information Center
McKenna, Michael C.; Conradi, Kristin; Lawrence, Camille; Jang, Bong Gee; Meyer, J. Patrick
2012-01-01
To examine the current state of reading attitudes among middle school students in the United States, a survey was developed and administered to 4,491 students in 23 states plus the District of Columbia. The instrument comprised four subscales measuring attitudes toward: recreational reading in print settings, recreational reading in digital…
Calibration of the Concorde radiation detection instrument and measurements at SST altitude.
DOT National Transportation Integrated Search
1971-06-01
Performance tests were carried out on a solar cosmic radiation detection instrument developed for the Concorde SST. The instrument calibration curve (log dose-rate vs instrument reading) was reasonably linear from 0.004 to 1 rem/hr for both gamma rad...
Reading recognition of pointer meter based on pattern recognition and dynamic three-points on a line
NASA Astrophysics Data System (ADS)
Zhang, Yongqiang; Ding, Mingli; Fu, Wuyifang; Li, Yongqiang
2017-03-01
Pointer meters are frequently applied to industrial production for they are directly readable. They should be calibrated regularly to ensure the precision of the readings. Currently the method of manual calibration is most frequently adopted to accomplish the verification of the pointer meter, and professional skills and subjective judgment may lead to big measurement errors and poor reliability and low efficiency, etc. In the past decades, with the development of computer technology, the skills of machine vision and digital image processing have been applied to recognize the reading of the dial instrument. In terms of the existing recognition methods, all the parameters of dial instruments are supposed to be the same, which is not the case in practice. In this work, recognition of pointer meter reading is regarded as an issue of pattern recognition. We obtain the features of a small area around the detected point, make those features as a pattern, divide those certified images based on Gradient Pyramid Algorithm, train a classifier with the support vector machine (SVM) and complete the pattern matching of the divided mages. Then we get the reading of the pointer meter precisely under the theory of dynamic three points make a line (DTPML), which eliminates the error caused by tiny differences of the panels. Eventually, the result of the experiment proves that the proposed method in this work is superior to state-of-the-art works.
Using the TOEFL to measure the reading proficiency levels of deaf college applicants.
LoMaglio, L J
1991-07-01
The TOEFL is widely used by colleges and universities in the United States and Canada to measure the English language proficiency levels of hearing international applicants. At the National Technical Institute for the Deaf, a faculty committee recommended that this popular test instrument be used to measure the English reading skills of deaf international applicants to the National Technical Institute for the Deaf. This study examined the merits of using the TOEFL to measure the English reading ability of hearing post-secondary international students seeking admission to English-based colleges and universities. Forty-one hearing foreign students were tested in the fall of 1989 at the English Language Institute at SUNY Buffalo. The instruments chosen were both the TOEFL and the California Achievement Test of reading ability. The majority of the research subjects who scored between 400 and 500 on the TOEFL achieved a grade level of less than 8.0 on the California Achievement Test.
The Meteorology Instrument on Viking Lander 1
NASA Technical Reports Server (NTRS)
1976-01-01
Those Martian weather reports, received here daily from more than 200 million miles away, start right here at Viking l's meteorology instrument. Mounted atop the extended boom, the meteorology sensors face away from the spacecraft. They stand about four feet above the surface and measure atmospheric pressure, temperature, wind velocity and wind direction. The cable parallel to the boom is connected inside the spacecraft body with the electronics for operating the sensors, reading the data and preparing it for transmission to Earth. A second Mars weather station will begin operation next month when Viking 2 lands somewhere in the planet's northern latitude Viking 2 arrives at Mars and goes into orbit tomorrow (August 7).
Instrument Development Procedures for Rapid Reading Rate Measures. Technical Report # 08-05
ERIC Educational Resources Information Center
Liu, Kimy; Carling, Kristy; Geller, Leanne Ketterlin; Tindal, Gerald
2008-01-01
In this study, we describe the development of rapid reading measures, sentences presented to students in a nearly subliminal manner, with a literal comprehension question asked following their removal. After administering alternate forms of these measures to students, we present the results from three statistical analyses to ascertain their…
[Educative intervention and development of position and critical reading].
Angulo-Bernal, Sonia Elizabeth; Leyva-González, Félix Arturo; Viniegra-Velázquez, Leonardo
2007-01-01
To investigate the professors of technical courses of the area of health, the effects of a promotional educative strategy of the participation in the development of a position prior to the education and of the aptitude for the critical theoretical text reading and information of educative research. A longitudinal study took place, of intervention. In order to measure the degree of development of a position before the education, it was applied to the instrument Concepts and ideas about education. It consists of 72 statements, organized in duple that expresses two different approaches from education: participative and passive. For the inquiry of the degree of development of critical reading two instruments were applied: 1) Theoretical text reading of education and, 2) Reading information of educative research, constituted both by 120 itemes. The validity and trustworthiness of the three instruments were valued by experts with experience in teaching and educative research. The strategy was implemented through activities in seminary form, which were done twice a week, with a duration of five hours per session, for nine months; within the activities outside the classroom, the student completed reading of a theoretical text and/or report of educative research and the resolution of a reading guide (task). During the activities in a propitious classroom, discussion atmosphere and promoting at any moment the participation of the students; a space for the reflective recovery of their own experience was opened, for the analysis and interchange of ideas and for the critic and self-criticism of the main educative practices. The professor intervened when individual participation diminished; he also channeled the discussion, indicating to the enlightening observations and strong arguments of the students. The three instruments were applied to the group of professors of technical courses (n = 10); the initial measurement was applied before initiating the educative strategy and the final measurement at the end of the same plan. The qualification of the instruments and the capture of information were made by a blind technical worker. Subsequent to the educative strategy we observed a statistically significant advance in position -inferred through its main indicator: critical theoretical text consequence- and reading. The advances shown in critical reading for information of educative research were below the critical theoretical text reading. The development of position before the education and the aptitudes for critical reading of theoretical texts and information of educative research, in professors of technical courses of the area of health, it is possible, if educative atmospheres are created that lead to the participation -halfway through by the critic.
Validation of the Resilience Scale for Adolescents in Norwegian adolescents 13-18 years.
Moksnes, Unni K; Haugan, Gørill
2018-03-01
Resilience is seen as a vital resource for coping and mental health in adolescents. However, there is no universally accepted theory or definition of resilience, leading to considerable challenges regarding how to operationalise and measure this construct. The study aimed at providing further knowledge of the psychometric properties (dimensionality, construct validity and internal consistency) of the 28-item version of the Resilience Scale for Adolescents (READ) in N = 1183 Norwegian adolescents, 13-18 years old. Dimensionality of READ was tested using confirmatory factor analysis (CFA). Convergent validity and reliability were tested using Pearson's correlation analysis, Cronbach's alpha and composite reliability. The CFA supported a modified, 20-item, five-factor structure with high reliability, supporting the dimensionality and internal consistency of the instrument. Convergent validity was confirmed where all factors correlated in expected directions with measures of sense of coherence, self-esteem, stress and depression. The psychometric properties of the READ need to be further evaluated in adolescents; however, the results indicate that a modified 20-item version of READ is adequate for assessing resilience in the present sample of Norwegian adolescents. © 2017 Nordic College of Caring Science.
Artifacts Of Spectral Analysis Of Instrument Readings
NASA Technical Reports Server (NTRS)
Wise, James H.
1995-01-01
Report presents experimental and theoretical study of some of artifacts introduced by processing outputs of two nominally identical low-frequency-reading instruments; high-sensitivity servo-accelerometers mounted together and operating, in conjunction with signal-conditioning circuits, as seismometers. Processing involved analog-to-digital conversion with anti-aliasing filtering, followed by digital processing including frequency weighting and computation of different measures of power spectral density (PSD).
Instrument for underwater high-angular resolution volume scattering function measurements
NASA Astrophysics Data System (ADS)
Dueweke, Paul W.; Bolstad, Jay; Leonard, Donald A.; Sweeney, Harold E.; Boyer, Philip A.; Winkler, Erik M.
1997-02-01
A prototype instrument for in situ measurements of the volume scattering function (VSF) and the beam attenuation of water has been built and tested in the EOO laboratory. The intended application of the instrument is the enhancement of Navy operational optical systems for finding and imaging underwater objects such as mines. A description of the apparatus that was built and preliminary laboratory data will be presented. The instrument measures the VSF, (beta) ((theta) ), near the optical axis in both the forward and back directions from approximately 0.2 degrees off axis to approximately 5 degrees in 0.1 degree steps and at side angles of 45 degrees, 90 degrees, and 135 degrees. A diode- pumped, frequency-doubled, Nd:YAG laser provides the 532 nm light. This is the most used wavelength for underwater optical systems. The forward and back scattered light is collected and focused to a plane where scattering angles in the water are mapped onto concentric rings. At this focal plane, a conical reflector compresses the annular optical data onto a line along the cone axis where it is read by a MOS linear image array providing over 500 separate angular measurements. The beam attenuation coefficient, c, is also measured by means of a unique dual path configuration.
Birch, M. Eileen; Ku, Bon-Ki; Evans, Douglas E.; Ruda-Eberenz, Toni A.
2015-01-01
Production of carbon nanofibers and nanotubes (CNFs/CNTs) and their composite products is increasing globally. High volume production may increase the exposure risks for workers who handle these materials. Though health effects data for CNFs/CNTs are limited, some studies raise serious health concerns. Given the uncertainty about their potential hazards, there is an immediate need for toxicity data and field studies to assess exposure to CNFs/CNTs. An extensive study was conducted at a facility that manufactures and processes CNFs. Filter, sorbent, cascade impactor, bulk, and microscopy samples, combined with direct-reading instruments, provided complementary information on air contaminants. Samples were analyzed for organic carbon (OC) and elemental carbon (EC), metals, and polycyclic aromatic hydrocarbons (PAHs), with EC as a measure of CNFs. Transmission electron microscopy with energy-dispersive X-ray spectroscopy also was applied. Fine/ultrafine iron-rich soot, PAHs, and carbon monoxide were production byproducts. Direct-reading instrument results were reported previously [Evans DE et al. (Aerosol monitoring during carbon nanofiber production: mobile direct-reading sampling. Ann Occup Hyg 2010;54:514–31.)] Results for time-integrated samples are reported as companion papers in this Issue. OC and EC, metals, and microscopy results are reported here, in Part I, while results for PAHs are reported in Part II [Birch ME. (Exposure and Emissions Monitoring during Carbon Nanofiber Production—Part II: Polycyclic Aromatic Hydrocarbons. Ann. Occup. Hyg 2011; 55: 1037–47.)]. Respirable EC area concentrations inside the facility were about 6–68 times higher than outdoors, while personal breathing zone samples were up to 170 times higher. PMID:21965464
A Comparison of Piagetian Conservation Concepts with Reading Achievement.
ERIC Educational Resources Information Center
Caballero, Jane Alexis
This study involved a comparison of first and second grade students' performance on the Piagetian Task Administration Instrument (PTAI), the Metropolitan Readiness Test (MRT), and the Stanford Achievement Test (SAT) with actual reading achievement measured by placement on the Indiviudally Paced Instruction (IPI) Tracking Card in Reading, which was…
Arizona's Instrument to Measure Standards (AIMS HS). Student Guide
ERIC Educational Resources Information Center
Arizona Department of Education, 2006
2006-01-01
Arizona's Instrument to Measure Standards High School (AIMS HS) is an assessment program that measures high school students' achievement of the Arizona Academic Standards adopted by the state Board of Education in three subject areas: reading, writing, and mathematics. All students in high school are required to participate in AIMS HS testing.…
Eight microprocessor-based instrument data systems in the Galileo Orbiter spacecraft
NASA Technical Reports Server (NTRS)
Barry, R. C.
1980-01-01
Instrument data systems consist of a microprocessor, 3K bytes of Read Only Memory and 3K bytes of Random Access Memory. It interfaces with the spacecraft data bus through an isolated user interface with a direct memory access bus adaptor, and/or parallel data from instrument devices such as registers, buffers, analog to digital converters, multiplexers, and solid state sensors. These data systems support the spacecraft hardware and software communication protocol, decode and process instrument commands, generate continuous instrument operating modes, control the instrument mechanisms, acquire, process, format, and output instrument science data.
Print and Digital Texts: Evaluating the Differences in Reading Comprehension Strategies
ERIC Educational Resources Information Center
Maynard, Stephanie Elizabeth
2016-01-01
Concerns about the reading comprehension skills of students in the United States have been raised partly because of the introduction of digital products into their lives and the classroom setting. The Arizona Instrument to Measure Standards results from 2013 that were provided by the Arizona Department of Education indicated that reading scores…
Passive tracking scheme for a single stationary observer
NASA Astrophysics Data System (ADS)
Chan, Y. T.; Rea, Terry
2001-08-01
While there are many techniques for Bearings-Only Tracking (BOT) in the ocean environment, they do not apply directly to the land situation. Generally, for tactical reasons, the land observer platform is stationary; but, it has two sensors, visual and infrared, for measuring bearings and a laser range finder (LRF) for measuring range. There is a requirement to develop a new BOT data fusion scheme that fuses the two sets of bearing readings, and together with a single LRF measurement, produces a unique track. This paper first develops a parameterized solution for the target speeds, prior to the occurrence of the LRF measurement, when the problem is unobservable. At, and after, the LRF measurement, a BOT formulated as a least squares (LS) estimator then produces a unique LS estimate of the target states. Bearing readings from the other sensor serve as instrumental variables in a data fusion setting to eliminate the bias in the BOT estimator. The result is recursive, unbiased and decentralized data fusion scheme. Results from two simulation experiments have corroborated the theoretical development and show that the scheme is optimal.
Arizona's Instrument to Measure Standards (AIMS DPA). Student Guide. Grade 7
ERIC Educational Resources Information Center
Arizona Department of Education, 2006
2006-01-01
Arizona's Instrument to Measure Standards Dual Purpose Assessment (AIMS DPA) is a combination of two separate tests. One test is AIMS, which measures how well the student knows the reading, writing, and mathematics content that all Arizona students in the student's grade level are expected to know and be able to do. AIMS DPA includes…
Arizona's Instrument to Measure Standards (AIMS DPA). Student Guide. Grade 3
ERIC Educational Resources Information Center
Arizona Department of Education, 2006
2006-01-01
Arizona's Instrument to Measure Standards Dual Purpose Assessment (AIMS DPA) is a combination of two separate tests. One test is AIMS, which measures how well the student knows the reading, writing , and mathematics content that all Arizona students at the third grade level are expected to know and be able to do. AIMS includes multiple-choice…
Instruments for Reading Direct-Marked Data-Matrix Symbols
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Corder, Eric L.
2006-01-01
Improved optoelectronic instruments (specially configured digital cameras) for reading direct-marked data-matrix symbols on the surfaces of optically reflective objects (including specularly reflective ones) are undergoing development. Data-matrix symbols are two-dimensional binary patterns that are used, like common bar codes, for automated identification of objects. The first data-matrix symbols were checkerboard-like patterns of black-and-white rectangles, typically existing in the forms of paint, ink, or detachable labels. The major advantage of direct marking (the marks are more durable than are painted or printed symbols or detachable labels) is offset by a major disadvantage (the marks generated by some marking methods do not provide sufficient contrast to be readable by optoelectronic instruments designed to read black-and-white data-matrix symbols). Heretofore, elaborate lighting, lensing, and software schemes have been tried in efforts to solve the contrast problem in direct-mark matrix- symbol readers. In comparison with prior readers based on those schemes, the readers now undergoing development are expected to be more effective while costing less. All of the prior direct-mark matrix-symbol readers are designed to be aimed perpendicularly to marked target surfaces, and they tolerate very little angular offset. However, the reader now undergoing development not only tolerates angular offset but depends on angular offset as a means of obtaining the needed contrast, as described below. The prototype reader (see Figure 1) includes an electronic camera in the form of a charge-coupled-device (CCD) image detector equipped with a telecentric lens. It also includes a source of collimated visible light and a source of collimated infrared light for illuminating a target. The visible and infrared illumination complement each other: the visible illumination is more useful for aiming the reader toward a target, while the infrared illumination is more useful for reading symbols on highly reflective surfaces. By use of beam splitters, the visible and infrared collimated lights are introduced along the optical path of the telecentric lens, so that the target is illuminated and viewed from the same direction.
Instrument Development Procedures for Silent Reading Measures. Technical Report Number 08-03
ERIC Educational Resources Information Center
Liu, Kimy; Sundstrom-Hebert, Krystal; Ketterlin-Geller, Leanne R.; Tindal, Gerald
2008-01-01
The purpose of this study was to develop and gather validity evidence for silent reading fluency passages. A number of passages were written following a traditional story grammar structure (character, setting, events) and placed on a computer for students to read silently. We describe in detail, the manner in which content-related evidence was…
ERIC Educational Resources Information Center
Kavale, Kenneth A.
Sixteen sixth-grade students participated in a study of the reasoning strategies employed by good and poor readers. Students, trained in applying introspective procedures, completed instruments that measured verbal reasoning, determining cause and effect, reading for inference, and determining main idea. Protocols obtained during five consecutive…
Accounting For Nonlinearity In A Microwave Radiometer
NASA Technical Reports Server (NTRS)
Stelzried, Charles T.
1991-01-01
Simple mathematical technique found to account adequately for nonlinear component of response of microwave radiometer. Five prescribed temperatures measured to obtain quadratic calibration curve. Temperature assumed to vary quadratically with reading. Concept not limited to radiometric application; applicable to other measuring systems in which relationships between quantities to be determined and readings of instruments differ slightly from linearity.
Simulating a Direction-Finder Search for an ELT
NASA Technical Reports Server (NTRS)
Bream, Bruce
2005-01-01
A computer program simulates the operation of direction-finding equipment engaged in a search for an emergency locator transmitter (ELT) aboard an aircraft that has crashed. The simulated equipment is patterned after the equipment used by the Civil Air Patrol to search for missing aircraft. The program is designed to be used for training in radio direction-finding and/or searching for missing aircraft without incurring the expense and risk of using real aircraft and ground search resources. The program places a hidden ELT on a map and enables the user to search for the location of the ELT by moving a 14 NASA Tech Briefs, March 2005 small aircraft image around the map while observing signal-strength and direction readings on a simulated direction- finding locator instrument. As the simulated aircraft is turned and moved on the map, the program updates the readings on the direction-finding instrument to reflect the current position and heading of the aircraft relative to the location of the ELT. The software is distributed in a zip file that contains an installation program. The software runs on the Microsoft Windows 9x, NT, and XP operating systems.
Finnie, Ramona K.C.; Felder, Tisha M.; Linder, Suzanne Kneuper; Mullen, Patricia Dolan
2010-01-01
Background Consideration of categories related to reading comprehension—beyond reading level—is imperative to reach low literacy populations effectively. “Suitability” has been proposed as a term to encompass six categories of such factors: content, literacy demand graphics, layout/typography, learning stimulation, and cultural appropriateness. Our purpose was to describe instruments used to evaluate categories of suitability in cancer education materials in published reports and their findings. Methods We searched databases and reference lists for evaluations of print and Web-based cancer education materials to identify and describe measures of these categories. Studies had to evaluate reading level and at least one category of suitability. Results Eleven studies met our criteria.. Seven studies reported inter-rater reliability. Cultural appropriateness was most often assessed; four instruments assessed only surface aspects of cultural appropriateness. Only two of seven instruments used, the Suitability Assessment of Materials (SAM) and the Comprehensibility Assessment of Materials (SAM + CAM), were described as having any evidence of validity. Studies using SMOG and Fry reported higher average reading level scores than those using FK. Most materials failed criteria for reading level and cultural appropriateness. Conclusions We recommend more emphasis on the categories of suitability for those developing cancer education materials and more study of these categories and reliability and validity testing of instruments. PMID:20237884
Characterization of indoor diesel exhaust emissions from the parking garage of a school.
Debia, Maximilien; Trachy-Bourget, Marie-Claude; Beaudry, Charles; Neesham-Grenon, Eve; Perron, Stéphane; Lapointe, Caroline
2017-02-01
Diesel exhaust (DE) emissions from a parking garage located in the basement of a school were characterized during spring and winter using direct reading devices and integrated sampling methods. Concentrations of CO and NO 2 were evaluated using electrochemical sensors and passive colorimetric tubes, respectively. Elemental and total carbon concentrations were measured using the NIOSH 5040 method. Particle number concentrations (PNCs), respirable particulate matter (PM resp ) mass concentrations, and size distributions were evaluated using direct reading devices. Indoor concentrations of elemental carbon, PNC, CO, and NO 2 showed significant seasonal variation; concentrations were much higher during winter (p < 0.01). Concentrations of the PM resp and total carbon did not show significant seasonal variation. Pearson correlation coefficients were 0.9 (p < 0.01) and 0.94 (p < 0.01) between the parking garage and ground floor average daily PNCs, and between the parking garage and first floor average daily PNCs, respectively. Since DE is the main identified source of fine and ultrafine particles in the school, these results suggest that DE emissions migrate from the parking garage into the school. Our results highlight the relevance of direct reading instruments in identifying migration of contaminants and suggest that monitoring PNC is a more specific way of assessing exposure to DE than monitoring the common PM resp fraction.
Measuring Accurately Single-Phase Sinusoidal and Non-Sinusoidal Power.
1983-01-01
current component. Since the induction watthour meter is designed for measuring ac variations only, the creation of a dc component in an ac circuit due...available and the basic principle of measurement used in each. 3.1 Power Measuring Meters Instruments designed to measure the amount of average power...1.0 percent of full scale and + 0.5% of reading. 3.2 Encrgy Measuring Meters Instruments designed to measure the amount of power consumed in a circuit
The observatories and instruments of Tycho Brahe
NASA Astrophysics Data System (ADS)
Wolfschmidt, Gudrun
Tycho Brahe (1546-1601) was the most important observational astronomer until the invention of the telescope in 1608. By construction new instruments and devising new observing methods, Tycho succeeded in significantly increasing measurement accuracy: He increased the size of his instruments (e.g. a large wooden quadrant of diameter 5.4 m and a mural quadrant); he used metal and masonry rather than wood; he modified construction techniques to achieve greater stability; to provide shelter from the wind, his instruments were in subterranean nooks; his instruments were permanently and solidly mounted; for better angular readings, he developed new subdivisions and diopters (Tycho used transversals to obtain the greatest possible angular resolution readings. His instrumental sights (diopters) were specially designed to minimize errors); he carefully analysed all the errors (Tycho's aim was to reduce thethe uncertainty to less than one minute of arc); he used fundamental stars for the first time; he preferred measuring equatorial coordinates directly instead of using the zodiacal system, i.e. using the equatorial armillary sphere instead of the zodiacal armillary sphere; he tried a new measuring method with clocks and his mural quadrant (1582) for determining the right ascension; he took atmospheric refraction into account. Most of his high-accuracy instruments have been distroyed. Only two sextants, made by Jost Bürgi and Erasmus Habermel around 1600, still exist in the Narodny Technicky Muzeum (NTM) [National Technical Museum] in Prague. A model of the wooden quadrant is in the old observatory in Copenhagen, in the round tower. But we have good descriptions of the instruments (half circles of 2.3 m radius, quadrants up to 2 m radius including the mural quadrant, sextants up to 1.6 m, armillary spheres of 1.5 m radius and the great equatorial armillary sphere of 2.7 m, triquetrum and celestial globe of 1.5 m) in Tycho's book Astronomiae instauratae mechanica (Wandesburgi 1598, Nuremberg 1602). One of Tycho's instruments in original size was reconstructed in Oldenburg University and in the Steno Museum in Aarhus, Denmark. In Munich, in the Deutsches Museum's permanent astronomy exhibition (opened in 1992), the Uraniborg observatory and its instruments are shown at a scale of 1:10. A similar but larger model (scale 1:5) from the workshop of the Deutsches Museum was given to the Technical Museum in Malmø, Sweden. Tycho's later observatory Stjerneborg can be seen as a reconstruction on the island Hven (Ven/Sweden) with the original foundations for the instruments.
2013-04-02
photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method to determine correlation between the two...study compared the non-specific, rapid photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method...mask confidence training (27) . This study will compare a direct reading, non-specific photometric particle count instrument (DustTrak TSI Model
Diesel exhaust exposures in port workers.
Debia, Maximilien; Neesham-Grenon, Eve; Mudaheranwa, Oliver C; Ragettli, Martina S
2016-07-01
Exposure to diesel engine exhaust has been linked to increased cancer risk and cardiopulmonary diseases. Diesel exhaust is a complex mixture of chemical substances, including a particulate fraction mainly composed of ultrafine particles, resulting from the incomplete combustion of fuel. Diesel trucks are known to be an important source of diesel-related air pollution, and areas with heavy truck traffic are associated with higher air pollution levels and increased public health problems. Several indicators have been proposed as surrogates for estimating exposures to diesel exhaust but very few studies have focused specifically on monitoring the ultrafine fraction through the measurement of particle number concentrations. The aim of this study is to assess occupational exposures of gate controllers at the port of Montreal, Canada, to diesel engine emissions from container trucks by measuring several surrogates through a multimetric approach which includes the assessment of both mass and number concentrations and the use of direct reading devices. A 10-day measurement campaign was carried out at two terminal checkpoints at the port of Montreal. Respirable elemental and organic carbon, PM1, PM2.5, PMresp (PM4), PM10, PMtot (inhalable fraction), particle number concentrations, particle size distributions, and gas concentrations (NO2, NO, CO) were monitored. Gate controllers were exposed to concentrations of contaminants associated with diesel engine exhaust (elemental carbon GM = 1.6 µg/m(3); GSD = 1.6) well below recommended occupational exposure limits. Average daily particle number concentrations ranged from 16,544-67,314 particles/cm³ (GM = 32,710 particles/cm³; GSD = 1.6). Significant Pearson correlation coefficients were found between daily elemental carbon, PM fractions and particle number concentrations, as well as between total carbon, PM fractions and particle number concentrations. Significant correlation coefficients were found between particle number concentrations and the number of trucks and wind speed (R(2) = 0.432; p < 0.01). The presence of trucks with cooling systems and older trucks with older exhaust systems was associated with peak concentrations on the direct reading instruments. The results highlight the relevance of direct reading instruments in helping to identify sources of exposure and suggest that monitoring particle number concentrations improves understanding of workers' exposures to diesel exhaust. This study, by quantifying workers' exposure levels through a multimetric approach, contributes to the further understanding of occupational exposures to diesel engine exhaust.
ERIC Educational Resources Information Center
Baker, Scott K.; Gersten, Russell; Haager, Diane; Dingle, Mary; Goldenberg, Claude
2005-01-01
Validation of a classroom observation measure for use with English Learners (ELs) in Grade 1 is the focus of this study. Fourteen teachers were observed during reading and language arts instruction with an instrument used to generate overall ratings of instructional quality on a number of dimensions. In these classrooms, the reading performance of…
Evaluation of potential site for mineral processing plant
NASA Astrophysics Data System (ADS)
Izwan Ishak, Muhamad Noor; Sipaun, Susan Maria; Mustapha, Ismail; Fahmi Engku Chik, Engku Mohd; Abdullah, Nurliyana; Affandi Mahmood, Airwan
2018-01-01
Nuclear moisture-density gauge is a type of instrument for measuring density and moisture of the material in a relatively thin zone beneath a surface of the material by using low activity of neutron and gamma radiation source. Density and moisture content data of the compacted layers are needed to determine the degree of compaction of soils, aggregate, concrete, asphalt or other materials used in civil engineering works. A gamma radiation source is mounted inside gauge housing with the source rod vertically extended to various depth positions. Direct transmission gamma radiation technique is used to obtain the count reading for the number of photons emitted before it is converted into density reading by microprocessor. This paper presents the inspection technique and results for the measurement of soil moisture and density carried out at potential site for mineral processing plant, Malaysian Nuclear Agency. Primarily, the experiment was conducted to ensure the compaction of ground is suitable for the plant construction. From the calculation, the percentages of soil wet density compaction (%WD Compact) are within acceptable limits with respect to the standard compacted wet soil density measured in the laboratory.
Intertester agreement in refractive error measurements.
Huang, Jiayan; Maguire, Maureen G; Ciner, Elise; Kulp, Marjean T; Quinn, Graham E; Orel-Bixler, Deborah; Cyert, Lynn A; Moore, Bruce; Ying, Gui-Shuang
2013-10-01
To determine the intertester agreement of refractive error measurements between lay and nurse screeners using the Retinomax Autorefractor and the SureSight Vision Screener. Trained lay and nurse screeners measured refractive error in 1452 preschoolers (3 to 5 years old) using the Retinomax and the SureSight in a random order for screeners and instruments. Intertester agreement between lay and nurse screeners was assessed for sphere, cylinder, and spherical equivalent (SE) using the mean difference and the 95% limits of agreement. The mean intertester difference (lay minus nurse) was compared between groups defined based on the child's age, cycloplegic refractive error, and the reading's confidence number using analysis of variance. The limits of agreement were compared between groups using the Brown-Forsythe test. Intereye correlation was accounted for in all analyses. The mean intertester differences (95% limits of agreement) were -0.04 (-1.63, 1.54) diopter (D) sphere, 0.00 (-0.52, 0.51) D cylinder, and -0.04 (1.65, 1.56) D SE for the Retinomax and 0.05 (-1.48, 1.58) D sphere, 0.01 (-0.58, 0.60) D cylinder, and 0.06 (-1.45, 1.57) D SE for the SureSight. For either instrument, the mean intertester differences in sphere and SE did not differ by the child's age, cycloplegic refractive error, or the reading's confidence number. However, for both instruments, the limits of agreement were wider when eyes had significant refractive error or the reading's confidence number was below the manufacturer's recommended value. Among Head Start preschool children, trained lay and nurse screeners agree well in measuring refractive error using the Retinomax or the SureSight. Both instruments had similar intertester agreement in refractive error measurements independent of the child's age. Significant refractive error and a reading with low confidence number were associated with worse intertester agreement.
Lake Shore Drive\\\\Grand Ave.\\\\E. Illinois Ave., May 2016, Lindsay Light Radiological Survey
Field gamma measurements process did not exceed the instrument threshold. Unshielded readings ranged from a minimumof 4,600 cpm to a maximum of 14,200 cpm unshielded and shielded readings ranged from a minimum of1,800 cpm to 2,680 cpm.
ERIC Educational Resources Information Center
Zeuch, Nina; Förster, Natalie; Souvignier, Elmar
2017-01-01
Learning progress assessment (LPA) provides formative information about effectiveness of instructional decisions. Learning curves are usually presented as graphical illustrations. However, little is known about teachers understanding and interpreting of graphically presented information. An instrument to measure competencies in reading graphs from…
ERIC Educational Resources Information Center
Stanley, Christopher T.; Petscher, Yaacov; Catts, Hugh
2018-01-01
In this study, researchers examined the extent to which several fundamental measures of reading proficiency from kindergarten students (N = 3180) were linked to reading comprehension in tenth grade while controlling for third grade vocabulary and oral reading fluency. Analyses tested the direct and indirect relations between and among…
Event-based Plausibility Immediately Influences On-line Language Comprehension
Matsuki, Kazunaga; Chow, Tracy; Hare, Mary; Elman, Jeffrey L.; Scheepers, Christoph; McRae, Ken
2011-01-01
In some theories of sentence comprehension, linguistically-relevant lexical knowledge such as selectional restrictions is privileged in terms of the time-course of its access and influence. We examined whether event knowledge computed by combining multiple concepts can rapidly influence language understanding even in the absence of selectional restriction violations. Specifically, we investigated whether instruments can combine with actions to influence comprehension of ensuing patients. Instrument-verb-patient triplets were created in a norming study designed to tap directly into event knowledge. In self-paced reading (Experiment 1), participants were faster to read patient nouns such as hair when they were typical of the instrument-action pair (Donna used the shampoo to wash vs. the hose to wash). Experiment 2 showed that these results were not due to direct instrument-patient relations. Experiment 3 replicated Experiment 1 using eyetracking, with effects of event typicality observed in first fixation and gaze durations on the patient noun. This research demonstrates that conceptual event-based expectations are computed and used rapidly and dynamically during on-line language comprehension. We discuss relationships among plausibility and predictability, as well as their implications. We conclude that selectional restrictions may be best considered as event-based conceptual knowledge, rather than lexical-grammatical knowledge. PMID:21517222
Direct Reading Instruction and the NYS ELA
ERIC Educational Resources Information Center
Jones-Carey, Margaret H.
2013-01-01
This study analyzed the impact of classroom based reading instruction ("direct instruction") on the standardized test scores of 6th grade students as measured by the New York State English Language Arts assessment (NYS ELA). It was hypothesized that the implementation of direct instruction in reading in grade 6 would improve NYS ELA…
Readability of Self-Report Alcohol Misuse Measures
McHugh, R Kathryn; Sugarman, Dawn E; Kaufman, Julia S; Park, Sara; Weiss, Roger D; Greenfield, Shelly F
2014-01-01
Objective: Self-report measures of alcohol misuse and alcohol use disorders are valuable assessment tools for both research and clinical practice settings. However, readability is often overlooked when establishing the validity of these measures, which may result in measures written at a reading-grade level that is higher than the ability level of many potential respondents. The aim of the current study was to estimate the reading-grade level of validated measures of alcohol misuse and associated problems. Method: A total of 45 measures were identified, and reading-grade level was calculated using three validated readability formulas. Results: The majority of measures were written above the recommended reading-grade level for patient materials (5th–6th grade), with particularly poor readability for measure instructions. Conclusions: Given that many self-report alcohol misuse measures are written at a high reading-grade level, the consideration of readability is important when selecting measures for use in research and practice settings. Moreover, the development or modification of measures to target low-literacy populations may facilitate the broader applicability of these instruments. PMID:24650827
Informal Assessment in Reading: Group vs. Individual.
ERIC Educational Resources Information Center
Shipman, Dorothy A.; Warncke, Edna W.
A study was conducted to determine whether informal group assessment instruments could be used effectively to provide the same type of reading achievement information as that secured from informal individual instruments. The researchers developed group instruments comparable to individual instruments, including a group reading inventory for grades…
Monitoring Error Rates In Illumina Sequencing.
Manley, Leigh J; Ma, Duanduan; Levine, Stuart S
2016-12-01
Guaranteeing high-quality next-generation sequencing data in a rapidly changing environment is an ongoing challenge. The introduction of the Illumina NextSeq 500 and the depreciation of specific metrics from Illumina's Sequencing Analysis Viewer (SAV; Illumina, San Diego, CA, USA) have made it more difficult to determine directly the baseline error rate of sequencing runs. To improve our ability to measure base quality, we have created an open-source tool to construct the Percent Perfect Reads (PPR) plot, previously provided by the Illumina sequencers. The PPR program is compatible with HiSeq 2000/2500, MiSeq, and NextSeq 500 instruments and provides an alternative to Illumina's quality value (Q) scores for determining run quality. Whereas Q scores are representative of run quality, they are often overestimated and are sourced from different look-up tables for each platform. The PPR's unique capabilities as a cross-instrument comparison device, as a troubleshooting tool, and as a tool for monitoring instrument performance can provide an increase in clarity over SAV metrics that is often crucial for maintaining instrument health. These capabilities are highlighted.
Coutinho-Sacadura course corrector
NASA Technical Reports Server (NTRS)
SACADURA CABRAL
1922-01-01
The Coutinho-Sacadura course corrector is an instrument with which, knowing the angles of drift of two different courses, we may determine by simple readings: a) direction and velocity of wind; b) correction to be made in course followed by compass, in order to fly in a given direction; c) ground-speed of aircraft, the resultant of its air speed and the velocity of the wind.
Working Memory Capacity and L2 University Students' Comprehension of Linear Texts and Hypertexts
ERIC Educational Resources Information Center
Fontanini, Ingrid; Tomitch, Leda Maria Braga
2009-01-01
The aim of this study was to investigate the relationship between working memory capacity and L2 reading comprehension of both linear texts and hypertexts. Three different instruments were used to measure comprehension (recall, comprehension questions and perception of contradictions) and the Reading Span Test (Daneman & Carpenter, 1980) was…
7 CFR 28.603 - Procedures for air flow tests of micronaire reading.
Code of Federal Regulations, 2010 CFR
2010-01-01
... of the United States for Fiber Fineness and Maturity § 28.603 Procedures for air flow tests of... 7 Agriculture 2 2010-01-01 2010-01-01 false Procedures for air flow tests of micronaire reading...) Air flow instrument complete with accessories to measure the fineness and maturity, in combination, of...
Lee, Jaime B; Moore Sohlberg, McKay
2013-05-01
This pilot study investigated the impact of direct attention training combined with metacognitive facilitation on reading comprehension in individuals with aphasia. A single-subject, multiple baseline design was employed across 4 participants to evaluate potential changes in reading comprehension resulting from an 8-week intervention using Attention Process Training-3 (APT-3). The primary outcome measure was a maze reading task. Pre- and posttesting included attention and reading comprehension measures. Visual inspection of graphed performance data across conditions was used as the primary method of analysis. Treatment effect sizes were calculated for changes in reading comprehension probes from baseline to maintenance phases. Two of the study's 4 participants demonstrated improvements in maze reading, with corresponding effect sizes that were small in magnitude according to benchmarks for aphasia treatment research. All 4 participants made improvements on select standardized measures of attention. Interventions that include a metacognitive component with direct attention training may elicit improvements in participants' attention and allocation of resources. Maze passage reading is a repeated measure that appears sensitive to treatment-related changes in reading comprehension. Issues for future research related to measurement, candidacy, and clinical delivery are discussed.
NREL National Wind Technology Center (NWTC): M2 Tower; Boulder, Colorado (Data)
Jager, D.; Andreas, A.
1996-09-24
The National Wind Technology Center (NWTC), located at the foot of the Rocky Mountains near Boulder, Colorado, is a world-class research facility managed by NREL for the U.S. Department of Energy. NWTC researchers work with members of the wind energy industry to advance wind power technologies that lower the cost of wind energy through research and development of state-of-the-art wind turbine designs. NREL's Measurement and Instrument Data Center provides data from NWTC's M2 tower which are derived from instruments mounted on or near an 82 meter (270 foot) meteorological tower located at the western edge of the NWTC site and about 11 km (7 miles) west of Broomfield, and approximately 8 km (5 miles) south of Boulder, Colorado. The data represent the mean value of readings taken every two seconds and averaged over one minute. The wind speed and direction are measured at six heights on the tower and air temperature is measured at three heights. The dew point temperature, relative humidity, barometric pressure, totalized liquid precipitation, and global solar radiation are also available.
Wang, Ye; Silvestri, Julia A; Jahromi, Laudan B
2018-01-01
The purpose of the study was to identify factors related to reading comprehension, and to compare similarities and differences in the reading processes of deaf and hearing adults. The sample included four groups, each consisting of 15 adults. The groups were identified as (a) deaf high-achieving readers, (b) deaf low-achieving readers, (c) hearing high-achieving readers, and (d) hearing low-achieving readers. Measurement instruments included a demographic form along with assessments of reading comprehension, phonological skills, and metacognition, the latter of which contained both a making-inferences measure and a think-aloud discussion with a reading strategies checklist. Results indicated that deaf high-achieving readers performed similarly to hearing high-achieving readers, except for phonological skills, and that for all participants, phonological skills and metacognition were related to reading comprehension skills.
NASA Astrophysics Data System (ADS)
Fisher, William P., Jr.; Stenner, A. Jackson
2013-09-01
The public and researchers in psychology and the social sciences are largely unaware of the huge resources invested in metrology and standards in science and commerce, for understandable reasons, but with unfortunate consequences. Measurement quality varies widely in fields lacking uniform standards, making it impossible to coordinate local behaviours and decisions in tune with individually observed instrument readings. However, recent developments in reading measurement have effectively instituted metrological traceability methods within elementary and secondary English and Spanish language reading education in the U.S., Canada, Mexico, and Australia. Given established patterns in the history of science, it may be reasonable to expect that widespread routine reproduction of controlled effects expressed in uniform units in the social sciences may lead to significant developments in theory and practice.
Effectiveness of Miles-Per-Gallon Meters as a Means to Conserve Gasoline in Automobiles
DOT National Transportation Integrated Search
1976-10-01
This report is an assessment of fuel flow instruments reading directly in miles per gallon (mpg). It describes currently available mpg meters, their installation, utility, and safety and presents an analysis of potential cost savings. It discusses me...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gressel, M.G.; Heitbrink, W.A.; Jensen, P.A.
1992-08-01
The techniques for conducting video exposure monitoring were described along with the equipment required to monitor and record worker breathing zone concentrations, the analysis of the real time exposure data using video recordings, and the use of real time concentration data from a direct reading instrument to determine the effective ventilation rate and the mixing factor of a given room at a specific time. Case studies which made use of video exposure monitoring techniques to provide information not available through integrated sampling were also discussed. The process being monitored and the methodology used to monitor the exposures were described formore » each of the case studies. The case studies included manual material weigh out, ceramic casting cleaning, dumping bags of powdered materials, furniture stripping, administration of nitrous-oxide during dental procedures, hand held sanding operation, methanol exposures in maintenance garages, brake servicing, bulk loading of railroad cars and trucks, and grinding operations.« less
Chelton, C F; Zakraysek, N; Lautner, G M; Confer, R G
1983-10-01
Two direct reading instruments, the H-Nu PI 101 photoionization analyzer and the J.W. Bacharach TLV Sniffer, were evaluated under laboratory conditions to determine their performance characteristics when challenged by vapors of common hydrocarbon solvent mixtures. Each instrument was evaluated against the manufacturer's recommended test solvent for rise time, fall time, noise, span drift, zero drift, position sensitivity, battery life, and recharge time. The precision, accuracy, and operating linear range were also determined for the test solvents and some petroleum solvent mixtures which are common refinery products. For these latter mixtures, correction factors are presented which allow for an improved estimate of ambient concentrations when monitoring with each of these instruments. All tests except operating humidity range were performed by challenging each instrument with a known concentration of hydrocarbon generated by evaporating calculated liquid volumes into a static chamber. Humidity tests were performed using a dynamic dilution apparatus generating a fixed concentration of hydrocarbon while relative humidity was varied. Concentrations in both systems were verified by gas injection into gas chromatograph. Each instrument performed well when challenged by manufacturers' recommended test solvents. Humidity was shown to influence each instrument's readings. Also, the instruments were shown to have application as monitors of airborne concentrations of common hydrocarbon solvent mixtures.
Development of Portable Aerosol Mobility Spectrometer for Personal and Mobile Aerosol Measurement
Kulkarni, Pramod; Qi, Chaolong; Fukushima, Nobuhiko
2017-01-01
We describe development of a Portable Aerosol Mobility Spectrometer (PAMS) for size distribution measurement of submicrometer aerosol. The spectrometer is designed for use in personal or mobile aerosol characterization studies and measures approximately 22.5 × 22.5 × 15 cm and weighs about 4.5 kg including the battery. PAMS uses electrical mobility technique to measure number-weighted particle size distribution of aerosol in the 10–855 nm range. Aerosol particles are electrically charged using a dual-corona bipolar corona charger, followed by classification in a cylindrical miniature differential mobility analyzer. A condensation particle counter is used to detect and count particles. The mobility classifier was operated at an aerosol flow rate of 0.05 L/min, and at two different user-selectable sheath flows of 0.2 L/min (for wider size range 15–855 nm) and 0.4 L/min (for higher size resolution over the size range of 10.6–436 nm). The instrument was operated in voltage stepping mode to retrieve the size distribution, which took approximately 1–2 minutes, depending on the configuration. Sizing accuracy and resolution were probed and found to be within the 25% limit of NIOSH criterion for direct-reading instruments (NIOSH 2012). Comparison of size distribution measurements from PAMS and other commercial mobility spectrometers showed good agreement. The instrument offers unique measurement capability for on-person or mobile size distribution measurements of ultrafine and nanoparticle aerosol. PMID:28413241
Electric-Field Instrument With Ac-Biased Corona Point
NASA Technical Reports Server (NTRS)
Markson, R.; Anderson, B.; Govaert, J.
1993-01-01
Measurements indicative of incipient lightning yield additional information. New instrument gives reliable readings. High-voltage ac bias applied to needle point through high-resistance capacitance network provides corona discharge at all times, enabling more-slowly-varying component of electrostatic potential of needle to come to equilibrium with surrounding air. High resistance of high-voltage coupling makes instrument insensitive to wind. Improved corona-point instrument expected to yield additional information assisting in safety-oriented forecasting of lighting.
ERIC Educational Resources Information Center
Arnold, Holly Weber
2013-01-01
This study examines the relationship between delivery models (the class size reduction model and the sheltered instruction model) and language development levels on the grade-level reading development of sixth-grade English learners (ELs) attending public middle schools in metro Atlanta, Georgia. The instrument used to measure grade-level mastery…
ERIC Educational Resources Information Center
Mokhtari, Kouider; Reichard, Carla
2004-01-01
This study investigated whether significant differences exist between first and second language readers in their metacognitive awareness and perceived use of specific strategies when reading for academic purposes in English. Three hundred and fifty college students (141 US and 209 Moroccan) completed an instrument designed to measure their…
ERIC Educational Resources Information Center
Soleimani, Hassan; Mohammadi, Elham
2012-01-01
This experimental study investigated the relationship between font type, font size, and line spacing and legibility, as measured by speed of reading, comprehension, and recalling. Instruments for testing legibility and reading comprehension were presented in eight typographical styles in print. The study tested 90 students for legibility and 76…
Instrumented Glove Measures Positions Of Fingers
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr.
1993-01-01
Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.
77 FR 38477 - IFR Altitudes; Miscellaneous Amendments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-28
... CONSEQUENCES, NM VORTAC. Sec. 95.4000 High Altitude RNAV Routes Sec. 95.4130 RNAV Route Q130 is Amended to Read.... No. 501] IFR Altitudes; Miscellaneous Amendments AGENCY: Federal Aviation Administration (FAA), DOT... (instrument flight rules) altitudes and changeover points for certain Federal airways, jet routes, or direct...
Fuchs, Douglas; Compton, Donald L.; Fuchs, Lynn S.; Bouton, Bobette; Caffrey, Erin
2016-01-01
The purpose of this study was to examine the construct and predictive validity of a dynamic assessment (DA) of decoding learning. Students (N = 318) were assessed in the fall of first grade on an array of instruments that were given in hopes of forecasting responsiveness to reading instruction. These instruments included DA as well as one-point-in-time (static) measures of early alphabetic knowledge, rapid automatized naming (RAN), phonemic awareness, oral vocabulary, listening comprehension, attentive behavior, and hyperactive or impulsive behavior. An IQ test was administered in spring of second grade. Measures of reading outcomes administered in spring of first grade were accuracy and fluency of word identification skills and reading comprehension. Factor analysis using principal axis factor extraction indicated that DA loaded on a first factor that also included language abilities and IQ, which the authors refer to as the “language, IQ, and DA” factor. It was relatively distinct from two additional factors: (a) “speeded alphabetic knowledge and RAN” and (b) “task-oriented behavior.” A three-level (children nested within classroom; classrooms nested within school) random intercept model with fixed effects predictors suggested that DA differed from word attack in predicting future reading skill and that DA was a significant predictor of responsiveness to instruction, contributing unique variance to end-of-first-grade word identification and reading comprehension beyond that explained by other well-established predictors of reading development. PMID:21685347
Readability and Comprehension of Self-Report Binge Eating Measures
Richards, Lauren K.; McHugh, R. Kathryn; Pratt, Elizabeth M.; Thompson-Brenner, Heather
2013-01-01
The validity of self-report binge eating instruments among individuals with limited literacy is uncertain. This study aims to evaluate reading grade level and multiple domains of comprehension of 13 commonly used self-report assessments of binge eating for use in low-literacy populations. We evaluated self-report binge eating measures with respect to reading grade levels, measure length, formatting and linguistic problems. Results: All measures were written at a reading grade level higher than is recommended for patient materials (above the 5th to 6th grade level), and contained several challenging elements related to comprehension. Correlational analyses suggested that readability and comprehension elements were distinct contributors to measure difficulty. Individuals with binge eating who have low levels of educational attainment or limited literacy are often underrepresented in measure validation studies. Validity of measures and accurate assessment of symptoms depends on an individual's ability to read and comprehend instructions and items, and these may be compromised in populations with lower levels of literacy. PMID:23557814
Readability and comprehension of self-report binge eating measures.
Richards, Lauren K; McHugh, R Kathryn; Pratt, Elizabeth M; Thompson-Brenner, Heather
2013-04-01
The validity of self-report binge eating instruments among individuals with limited literacy is uncertain. This study aims to evaluate reading grade level and multiple domains of comprehension of 13 commonly used self-report assessments of binge eating for use in low-literacy populations. We evaluated self-report binge eating measures with respect to reading grade levels, measure length, formatting and linguistic problems. All measures were written at a reading grade level higher than is recommended for patient materials (above the 5th to 6th grade level), and contained several challenging elements related to comprehension. Correlational analyses suggested that readability and comprehension elements were distinct contributors to measure difficulty. Individuals with binge eating who have low levels of educational attainment or limited literacy are often underrepresented in measure validation studies. Validity of measures and accurate assessment of symptoms depend on an individual's ability to read and comprehend instructions and items, and these may be compromised in populations with lower levels of literacy. Copyright © 2013 Elsevier Ltd. All rights reserved.
Nicholson, N.; Dowdy, E.J.; Holt, D.M.; Stump, C.J. Jr.
1982-05-13
A portable instrument for measuring induced Cerenkov radiation associated with irradiated nuclear fuel assemblies in a water-filled storage pond is disclosed. The instrument includes a photomultiplier tube and an image intensifier which are operable in parallel and simultaneously by means of a field lens assembly and an associated beam splitter. The image intensifier permits an operator to aim and focus the apparatus on a submerged fuel assembly. Once the instrument is aimed and focused, an illumination reading can be obtained with the photomultiplier tube. The instrument includes a lens cap with a carbon-14/phosphor light source for calibrating the apparatus in the field.
A predictive study of reading comprehension in third-grade Spanish students.
López-Escribano, Carmen; Elosúa de Juan, María Rosa; Gómez-Veiga, Isabel; García-Madruga, Juan Antonio
2013-01-01
The study of the contribution of language and cognitive skills to reading comprehension is an important goal of current reading research. However, reading comprehension is not easily assessed by a single instrument, as different comprehension tests vary in the type of tasks used and in the cognitive demands required. This study examines the contribution of basic language and cognitive skills (decoding, word recognition, reading speed, verbal and nonverbal intelligence and working memory) to reading comprehension, assessed by two tests utilizing various tasks that require different skill sets in third-grade Spanish-speaking students. Linguistic and cognitive abilities predicted reading comprehension. A measure of reading speed (the reading time of pseudo-words) was the best predictor of reading comprehension when assessed by the PROLEC-R test. However, measures of word recognition (the orthographic choice task) and verbal working memory were the best predictors of reading comprehension when assessed by means of the DARC test. These results show, on the one hand, that reading speed and word recognition are better predictors of Spanish language comprehension than reading accuracy. On the other, the reading comprehension test applied here serves as a critical variable when analyzing and interpreting results regarding this topic.
Georgiou, George; Liu, Cuina; Xu, Shiyang
2017-08-01
Associative learning, traditionally measured with paired associate learning (PAL) tasks, has been found to predict reading ability in several languages. However, it remains unclear whether it also predicts word reading in Chinese, which is known for its ambiguous print-sound correspondences, and whether its effects are direct or indirect through the effects of other reading-related skills such as phonological awareness and rapid naming. Thus, the purpose of this study was to examine the direct and indirect effects of visual-verbal PAL on word reading in an unselected sample of Chinese children followed from the second to the third kindergarten year. A sample of 141 second-year kindergarten children (71 girls and 70 boys; mean age=58.99months, SD=3.17) were followed for a year and were assessed at both times on measures of visual-verbal PAL, rapid naming, and phonological awareness. In the third kindergarten year, they were also assessed on word reading. The results of path analysis showed that visual-verbal PAL exerted a significant direct effect on word reading that was independent of the effects of phonological awareness and rapid naming. However, it also exerted significant indirect effects through phonological awareness. Taken together, these findings suggest that variations in cross-modal associative learning (as measured by visual-verbal PAL) place constraints on the development of word recognition skills irrespective of the characteristics of the orthography children are learning to read. Copyright © 2017 Elsevier Inc. All rights reserved.
Thousands of military personnel and tens of thousands of civilian workers perform tank entry procedures. OSHA regulations (1910.146) require the internal atmosphere be tested, with a calibrated direct-reading instrument, for oxygen content, flammable gases and vapors, and poten...
Assessing Motivation To Read. Instructional Resource No. 14.
ERIC Educational Resources Information Center
Gambrell, Linda B.; And Others
The Motivation to Read Profile (MRP) is a public-domain instrument designed to provide teachers with an efficient and reliable way to assess reading motivation qualitatively and quantitatively by evaluating students' self-concept as readers and the value they place on reading. The MRP consists of two basic instruments: the Reading Survey (a…
ERIC Educational Resources Information Center
Guymon, Ronald E.
An innovative classroom-based approach to reading instruction in the context of Spanish instruction was proposed. The effects of this instruction on the pronunciation ability of students were analyzed. The subjects were 30 adult missionary trainees who had no previous exposure to Spanish. The dependent variable was measured using two instruments.…
ERIC Educational Resources Information Center
Arnone, Marilyn P.; Small, Ruth V.; Weng, Shicheng
2016-01-01
Several instruments previously validated for use in school library research were tested for their appropriateness in the context of public libraries' summer reading programs for youth. The researchers were also interested in whether the connection between perceived competence in one's own information skills and perceived competence in one's own…
Measurement properties of continuous text reading performance tests.
Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B
2014-11-01
Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for reproducibility and repeatability studies. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
Instrumentation System Diagnoses a Thermocouple
NASA Technical Reports Server (NTRS)
Perotti, Jose; Santiago, Josephine; Mata, Carlos; Vokrot, Peter; Zavala, Carlos; Burns, Bradley
2008-01-01
An improved self-validating thermocouple (SVT) instrumentation system not only acquires readings from a thermocouple but is also capable of detecting deterioration and a variety of discrete faults in the thermocouple and its lead wires. Prime examples of detectable discrete faults and deterioration include open- and short-circuit conditions and debonding of the thermocouple junction from the object, the temperature of which one seeks to measure. Debonding is the most common cause of errors in thermocouple measurements, but most prior SVT instrumentation systems have not been capable of detecting debonding. The improved SVT instrumentation system includes power circuitry, a cold-junction compensator, signal-conditioning circuitry, pulse-width-modulation (PWM) thermocouple-excitation circuitry, an analog-to-digital converter (ADC), a digital data processor, and a universal serial bus (USB) interface. The system can operate in any of the following three modes: temperature measurement, thermocouple validation, and bonding/debonding detection. The software running in the processor includes components that implement statistical algorithms to evaluate the state of the thermocouple and the instrumentation system. When the power is first turned on, the user can elect to start a diagnosis/ monitoring sequence, in which the PWM is used to estimate the characteristic times corresponding to the correct configuration. The user also has the option of using previous diagnostic values, which are stored in an electrically erasable, programmable read-only memory so that they are available every time the power is turned on.
LOSS OF BLOOD AT OPERATION—A Method for Continuous Measurement
Borden, Fred W.
1957-01-01
A method for continuous measurement of surgical blood loss has been devised and has been used clinically in some 400 cases. The method combines volumetric measure of the suction loss and gravimetric measure of the sponge loss. The volumetric device automatically deducts the volume of rinse water used and thus measures the amount of blood collected in a metering cylinder. The suction loss scale shows continuously the amount of blood in the metering cylinder. The gravimetric device requires counting sponges into the weighing pan, and turning a dial scale to deduct the initial weight of the sponges. The volume of blood in the sponges is then read directly on the dial scale. Use of the instrument, which is under the supervision of the anesthesiologist, adds about two minutes per hour to the time normally required for counting the sponges; and about three minutes per hour is required for tending the volumetric instrument. In clinical use, knowing constantly the amount of blood loss permits the starting of transfusion before serious deficit develops, and then maintaining the patient's blood volume at a predetermined optimum level. In some 400 cases the continuous measurement of the blood loss served as a reliable guide for carrying out the loss-replacement plan within close limits of accuracy. ImagesFigure 2.p97-a PMID:13446754
An intelligent instrument for measuring exhaust temperature of marine engine
NASA Astrophysics Data System (ADS)
Ma, Nan-Qi; Su, Hua; Liu, Jun
2006-12-01
Exhaust temperature of the marine engine is commonly measured through thermocouple. Measure deviation will occur after using the thermocouple for some time due to nonlinearity of thermocouple itself, high temperature and chemical corrosion of measure point. Frequent replacement of thermocouple will increase the operating cost. This paper designs a new intelligent instrument for solving the above-mentioned problems of the marine engine temperature measurement, which combines the conventional thermocouple temperature measurement technology and SCM(single chip microcomputer). The reading of the thermocouple is simple and precise and the calibration can be made automatically and manually.
A Portable Solid-State Moisture Meter For Agricultural And Food Products
NASA Astrophysics Data System (ADS)
Bull, C. R.; Stafford, J. V.; Weaving, G. S.
1988-10-01
This paper reports on the development of a small, robust, battery operated near infra-red (NIR) reflectance device, designed for rapid on-farm measurement of the moisture content of forage crops without prior sample preparation. It has potential application to other agricultural or food materials. The instrument is based on two light emitting diodes (LEDs), a germanium detector and a control CMOS single chip microcomputer. The meter has been calibrated to give a direct read out of moisture content for 4 common grass varieties at 3 stages of development. The accuracy of a single point measurement on a grass sample is approximately +/- 6% over a range of 40-80% (wet basis). However, the potential accuracy on a homogeous sample may be as goon as 0.15%.
ERIC Educational Resources Information Center
Black, Talbot, Ed.
Eleven author contributed papers presented at a 1978 conference on measuring the growth and development of young handicapped children are presented. N. Anastasiow presents a rationale for measurement in his paper "A Philosophical Perspective: Why Measure Child Progress?'" Seven papers address instrument selection: "Screening, Diagnosis, and…
Administering a Group Reading Inventory: An Initiative in Improving Reading Instruction.
ERIC Educational Resources Information Center
Helfeldt, John P.; Henk, William A.
1983-01-01
Recommends the use of the Group Reading Inventory (GRI), an informal survey instrument, to identify general reading abilities of individuals in correctional facilities. Discusses why the GRI is appropriate for use, guidelines for constructing a GRI, and procedures for administering, scoring, and interpreting the instrument. (NRJ)
ERIC Educational Resources Information Center
Lokan, Janice J.
A Vocational Interest Inventory was developed for vocational high school students with low reading level, short test-attention span, low IQ, and impoverished educational and family background. The VII, of which there are separate versions for boys and girls, consists of items representing job tasks, for each of which the respondent indicates his…
A Study to Maximize the Learning Experience in the Physical Chemistry Laboratory
1979-01-01
commercial instrument is equipped with a platinum- iridium ring of standard dimen- sions for which the dial has been calibrated to read directly in dynes...a standard procedure with antimony trichloride in chloroform to produce a blue color. The percent transmission of the incident filtered light for each
Reliability and sensitivity of the TonoLab rebound tonometer in awake Brown Norway rats.
Morrison, John C; Jia, Lijun; Cepurna, William; Guo, Ying; Johnson, Elaine
2009-06-01
To compare the sensitivity of the TonoLab rebound tonometer with the Tono-Pen in awake Brown Norway rats and to compare their ability to predict optic nerve damage induced by experimental IOP elevation. TonoLab and Tono-Pen tonometers were calibrated in cannulated rat eyes connected to a pressure transducer. The TonoLab was used in awake animals housed in standard lighting to measure IOP during light and dark phases. Both instruments were used to monitor chronically elevated IOP produced by episcleral vein injection of hypertonic saline. Measured IOPs were correlated with quantified optic nerve damage in injected eyes. Although they were lower than transducer and Tono-Pen measurements at all levels, TonoLab readings showed an excellent linear fit with transducer readings from 20 to 80 mm Hg (R(2) = 0.99) in cannulated eyes. In awake animals housed in standard lighting, the TonoLab documented significantly higher pressures during the dark phase (27.9 +/- 1.7 mm Hg) than during the light phase (16.7 +/- 2.3 mm Hg). With elevated IOP, correlation between TonoLab and Tono-Pen readings (R(2) = 0.86, P < 0.0001) was similar to that in cannulated eyes. Although both instruments provided measurements that correlated well with optic nerve injury grade, only the Tono-Pen documented significant IOP elevation in eyes with the least amount of injury (P < 0.05). The TonoLab is sensitive enough to be used in awake Brown Norway rats, though instrument fluctuation may limit its ability to identify significant pressure elevations in eyes with minimal optic nerve damage.
ERIC Educational Resources Information Center
Cooper, Kary M.
2009-01-01
The purpose of this descriptive study was to determine if business leadership practices by Texas public school principals have an impact on principals' campus student achievement in mathematics and reading, as measured by TAKS scores. The survey instrument was the Leadership Assessment Instrument (LAI), developed by Warren Bennis in 1989. The…
CATS Concludes Successful Mission on ISS
Atmospheric Science Data Center
2018-02-15
... instrument has ended its operations on the International Space Station (ISS), after a successful 33-month mission to measure clouds and ... and the "NASA's CATS Concludes Successful Mission on Space Station" article. Read more ...
ERIC Educational Resources Information Center
Neugebauer, Sabina Rak
2017-01-01
While educators and researchers agree on the crucial role of literacy motivation for performance, research on methods for accurately assessing adolescent reading motivation is still uncommon. The most used reading motivation instruments do not attend to the multiple content areas in which adolescents read. The present study examines a new…
Generally objective measurement of human temperature and reading ability: some corollaries.
Stenner, A Jackson; Stone, Mark
2010-01-01
We argue that a goal of measurement is general objectivity: point estimates of a person's measure (height, temperature, and reader ability) should be independent of the instrument and independent of the sample in which the person happens to find herself. In contrast, Rasch's concept of specific objectivity requires only differences (i.e., comparisons) between person measures to be independent of the instrument. We present a canonical case in which there is no overlap between instruments and persons: each person is measured by a unique instrument. We then show what is required to estimate measures in this degenerate case. The canonical case encourages a simplification and reconceptualization of validity and reliability. Not surprisingly, this reconceptualization looks a lot like the way physicists and chemometricians think about validity and measurement error. We animate this presentation with a technology that blurs the distinction between instruction, assessment, and generally objective measurement of reader ability. We encourage adaptation of this model to health outcomes measurement.
Kirwan, John R; Fries, James F; Hewlett, Sarah E; Osborne, Richard H; Newman, Stanton; Ciciriello, Sabina; van de Laar, Mart A; Dures, Emma; Minnock, Patricia; Heiberg, Turid; Sanderson, Tessa C; Flurey, Caroline A; Leong, Amy L; Montie, Pamela; Richards, Pam
2011-08-01
The workshop Choosing or Developing Instruments held at the Outcome Measures in Rheumatology (OMERACT) 10 meeting was designed to help participants think about the underlying methods of instrument development. Conference pre-reading material and 3 brief introductory presentations elaborated the issues, and participants broke into discussion groups before reconvening to share insights, engage in a more general discussion of the issues, and vote on recommendations. Tradeoffs between using current imperfect measures and the long and complex process of developing new instruments were considered, together with the need for rigor in patient-reported outcome (PRO) instrument development. The main considerations for PRO instrument development were listed and a research agenda for action produced. As part of the agenda for action, it is recommended that researchers and patient partners work together to tackle these issues, and that OMERACT bring forward proposals for acceptable instrument development protocols that would meet an enhanced "Truth" statement in the OMERACT Filter.
Witchel, Harry J.; Santos, Carlos P.; Ackah, James K.; Westling, Carina E. I.; Chockalingam, Nachiappan
2016-01-01
Background: Estimating engagement levels from postural micromovements has been summarized by some researchers as: increased proximity to the screen is a marker for engagement, while increased postural movement is a signal for disengagement or negative affect. However, these findings are inconclusive: the movement hypothesis challenges other findings of dyadic interaction in humans, and experiments on the positional hypothesis diverge from it. Hypotheses: (1) Under controlled conditions, adding a relevant visual stimulus to an auditory stimulus will preferentially result in Non-Instrumental Movement Inhibition (NIMI) of the head. (2) When instrumental movements are eliminated and computer-interaction rate is held constant, for two identically-structured stimuli, cognitive engagement (i.e., interest) will result in measurable NIMI of the body generally. Methods: Twenty-seven healthy participants were seated in front of a computer monitor and speakers. Discrete 3-min stimuli were presented with interactions mediated via a handheld trackball without any keyboard, to minimize instrumental movements of the participant's body. Music videos and audio-only music were used to test hypothesis (1). Time-sensitive, highly interactive stimuli were used to test hypothesis (2). Subjective responses were assessed via visual analog scales. The computer users' movements were quantified using video motion tracking from the lateral aspect. Repeated measures ANOVAs with Tukey post hoc comparisons were performed. Results: For two equivalently-engaging music videos, eliminating the visual content elicited significantly increased non-instrumental movements of the head (while also decreasing subjective engagement); a highly engaging user-selected piece of favorite music led to further increased non-instrumental movement. For two comparable reading tasks, the more engaging reading significantly inhibited (42%) movement of the head and thigh; however, when a highly engaging video game was compared to the boring reading, even though the reading task and the game had similar levels of interaction (trackball clicks), only thigh movement was significantly inhibited, not head movement. Conclusions: NIMI can be elicited by adding a relevant visual accompaniment to an audio-only stimulus or by making a stimulus cognitively engaging. However, these results presume that all other factors are held constant, because total movement rates can be affected by cognitive engagement, instrumental movements, visual requirements, and the time-sensitivity of the stimulus. PMID:26941666
Witchel, Harry J; Santos, Carlos P; Ackah, James K; Westling, Carina E I; Chockalingam, Nachiappan
2016-01-01
Estimating engagement levels from postural micromovements has been summarized by some researchers as: increased proximity to the screen is a marker for engagement, while increased postural movement is a signal for disengagement or negative affect. However, these findings are inconclusive: the movement hypothesis challenges other findings of dyadic interaction in humans, and experiments on the positional hypothesis diverge from it. (1) Under controlled conditions, adding a relevant visual stimulus to an auditory stimulus will preferentially result in Non-Instrumental Movement Inhibition (NIMI) of the head. (2) When instrumental movements are eliminated and computer-interaction rate is held constant, for two identically-structured stimuli, cognitive engagement (i.e., interest) will result in measurable NIMI of the body generally. Twenty-seven healthy participants were seated in front of a computer monitor and speakers. Discrete 3-min stimuli were presented with interactions mediated via a handheld trackball without any keyboard, to minimize instrumental movements of the participant's body. Music videos and audio-only music were used to test hypothesis (1). Time-sensitive, highly interactive stimuli were used to test hypothesis (2). Subjective responses were assessed via visual analog scales. The computer users' movements were quantified using video motion tracking from the lateral aspect. Repeated measures ANOVAs with Tukey post hoc comparisons were performed. For two equivalently-engaging music videos, eliminating the visual content elicited significantly increased non-instrumental movements of the head (while also decreasing subjective engagement); a highly engaging user-selected piece of favorite music led to further increased non-instrumental movement. For two comparable reading tasks, the more engaging reading significantly inhibited (42%) movement of the head and thigh; however, when a highly engaging video game was compared to the boring reading, even though the reading task and the game had similar levels of interaction (trackball clicks), only thigh movement was significantly inhibited, not head movement. NIMI can be elicited by adding a relevant visual accompaniment to an audio-only stimulus or by making a stimulus cognitively engaging. However, these results presume that all other factors are held constant, because total movement rates can be affected by cognitive engagement, instrumental movements, visual requirements, and the time-sensitivity of the stimulus.
40 CFR 57.404 - Measurements, records, and reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and record at least one measurement of sulfur dioxide concentration and stack gas flow rate from the... manufacturer's recommended zero adjustment and calibration procedures at least once per 24-hour operating... which clearly show instrument readings before and after zero adjustment and calibration. (5) The results...
Atkinson, Lynette; Slade, Lance; Powell, Daisy; Levy, Joseph P
2017-12-01
The relation between children's theory of mind (ToM) and emerging reading comprehension was investigated in a longitudinal study over 2.5years. A total of 80 children were tested for ToM, decoding, language skills, and executive function (EF) at Time 1 (mean age=3;10 [years;months]). At Time 2 (mean age=6;03), children's word reading efficiency, language skills, and reading comprehension were measured. Mediation analysis showed that ToM at Time 1, when children were around 4years old, indirectly predicted Time 2 reading comprehension, when children were 6years old, via language ability after controlling for age, nonverbal ability, decoding, EF, and earlier language ability. Importantly, ToM at 4years also directly predicted reading comprehension 2.5years later at 6years. This is the first longitudinal study to show a direct contribution of ToM to reading comprehension in typical development. Findings are discussed in terms of the simple view of reading (SVR); ToM not only supports reading comprehension indirectly by facilitating language but also contributes to it directly over and above the SVR. The potential role of metacognition is considered when accounting for the direct contribution of early ToM to later reading comprehension. Copyright © 2017 Elsevier Inc. All rights reserved.
Early Identification of Reading Comprehension Difficulties.
Catts, Hugh W; Nielsen, Diane Corcoran; Bridges, Mindy Sittner; Liu, Yi-Syuan
2016-09-01
Most research on early identification of reading disabilities has focused on word reading problems and little attention has been given to reading comprehension difficulties. In this study, we investigated whether measures of language ability and/or response to language intervention in kindergarten uniquely predicted reading comprehension difficulties in third grade. A total of 366 children were administered a battery of screening measures at the beginning of kindergarten and progress monitoring probes across the school year. A subset of children also received a 26-week Tier 2 language intervention. Participants' achievement in word reading was assessed at the end of second grade, and their performance in reading comprehension was measured as the end of third grade. Results showed that measures of language ability in kindergarten significantly added to the prediction of reading comprehension difficulties over and above kindergarten word reading predictors and direct measures of word reading in second grade. Response to language intervention also proved to be a unique predictor of reading comprehension outcomes. Findings are discussed in terms of their relevance for the early identification of reading disabilities. © Hammill Institute on Disabilities 2014.
Hemoglobin spectra affect measurement of tissue oxygen saturation
NASA Astrophysics Data System (ADS)
Ostojic, Daniel; Kleiser, Stefan; Nasseri, Nassim; Isler, Helene; Scholkmann, Felix; Karen, Tanja; Wolf, Martin
2018-02-01
Tissue oxygen saturation (StO2) is a valuable clinical parameter e.g. for intensive care applications or monitoring during surgery. Studies showed that near-infrared spectroscopy (NIRS) based tissue oximeters of different brands give systematically different readings of StO2. Usually these readings are linearly correlated and therefore StO2 readings from one instrument can easily be converted to those of another instrument. However, it is interesting to understand why there is this difference. One reason may be that different brands employ different spectra of hemoglobin. The aim here was to investigate how these different absorption spectra of hemoglobin affect the StO2 readings. Therefore, we performed changes in StO2 in a phantom experiment with real human hemoglobin at three different concentrations (26.5, 45 and 70 μM): desaturation by yeast consuming the oxygen and re-saturation by bubbling oxygen gas. The partial pressure of O2 in the liquid changed from at least 10 kPa to 0 kPa and ISS OxiplexTS, a frequency-domain NIRS instrument, was used to monitor changes of StO2. When we employed two different absorption spectra for hemoglobin, StO2 values were comparable in the normal physiological range. However, particularly at high and low StO2 values, a difference of >6% between these two spectra were noticed. Such a difference of >6% is substantial and relevant for medical applications. This may partly explain why different brands of NIRS instruments provide different StO2 readings. The hemoglobin spectra are therefore a factor to be considered for future developments and applications of NIRS oximeters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
BUTLER, N.K.
2004-11-01
This document takes the newly released Industrial Hygiene Chemical Vapor Technical Basis (RPP-22491) and evaluates the chemicals of potential concern (COPC) identified for selected implementation actions by the industrial hygiene organization. This document is not intended as a hazard analysis with recommended controls for all tank farm activities. Not all of the chemicals listed are present in all tanks; therefore, hazard analyses can and should be tailored as appropriate. Detection of each chemical by current industrial hygiene non-specific instrumentation in use at the tank farms is evaluated. Information gaps are identified and recommendations are made to resolve these needs. Ofmore » the 52 COPC, 34 can be detected with existing instrumentation. Three additional chemicals could be detected with a photoionization detector (PID) equipped with a different lamp. Discussion with specific instrument manufacturers is warranted. Consideration should be given to having the SapphIRe XL customized for tank farm applications. Other instruments, sampling or modeling techniques should be evaluated to estimate concentrations of chemicals not detected by direct reading instruments. In addition, relative instrument response needs to be factored in to action levels used for direct reading instruments. These action levels should be correlated to exposures to the COPC and corresponding occupational exposure limits (OELs). The minimum respiratory protection for each of the COPC is evaluated against current options. Recommendations are made for respiratory protection based on each chemical. Until exposures are sufficiently quantified and analyzed, the current use of supplied air respiratory protection is appropriate and protective for the COPC. Use of supplied air respiratory protection should be evaluated once a detailed exposure assessment for the COPC is completed. The established tank farm OELs should be documented in the TFC-PLN-34. For chemicals without an established tank farm OEL, consideration should be given to adopting protective limits from NIOSH, AIHA, or developing OELs. Protective gloves and suits are evaluated for each chemical for which information is available. Information gaps are identified for some of the compounds and materials. Recommendations are made for resolving these needs. Based on available information, Silver Shield{reg_sign} gloves are promising for tank farm applications. However, permeation testing documentation is needed for the COPC and mixtures for Silver Shield{reg_sign} gloves to evaluate their protectiveness. North Safety Products is expected to provide the requested documentation. Multiple Tychem{reg_sign} products are available. There is overlap between chemicals and effective materials. Further hazard evaluation to determine actual hazards and permeation testing documentation is required to assess the efficacy of a single Tychem{reg_sign} product for tank farm applications. All of this chemical specific data is combined into a spreadsheet that will assist the industrial hygienist in the selection of monitoring instruments, respiratory protection selection and protective clothing for performing work at a specific tank(s).« less
How can teachers assess reading skills of generation z learners in German language class?
NASA Astrophysics Data System (ADS)
Dirga, R. N.; Wijayati, P. H.
2018-01-01
Generation Z is a digital native generation who has unique characteristics on the daily basis includes reading. In order to assess their reading skills correctly, teachers need to take these characteristics into consideration. This paper aims to describe the process in developing an instrument to assess reading skills of Generation Z learners in German language class. This study used developmental method. The developed instrument has not only good quality but also consists of texts that are suitable for German learners of Generation Z. This instrument can be used as an example in assessing German learners’ reading skills in the 21st century.
Measurement of lengths and angles by means of a photoelectric direct reading-off microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Priver, L.S.
1995-11-01
We consider the measurement of lengths and angles over a broad range with error amounting to fractions of a micrometer or angular second using a newly designed mockup of a photoelectric direct reading-off microscope. The microscope implements a pulse-position method of transforming information through application of a scanner in the form of a rotating polyhedral mirror.
Santos, Sandra; Cadime, Irene; Viana, Fernanda L; Chaves-Sousa, Séli; Gayo, Elena; Maia, José; Ribeiro, Iolanda
2017-02-01
Reading comprehension assessment should rely on valid instruments that enable adequate conclusions to be taken regarding students' reading comprehension performance. In this article, two studies were conducted to collect validity evidence for the vertically scaled forms of two Tests of Reading Comprehension for Portuguese elementary school students in the second to fourth grades, one with narrative texts (TRC-n) and another with expository ones (TRC-e). Two samples of 950 and 990 students participated in Study 1, the study of the dimensionality of the TRC-n and TRC-e forms, respectively. Confirmatory factor analyses provided evidence of an acceptable fit for the one-factor solution for all test forms. Study 2 included 218 students to collect criterion-related validity. The scores obtained in each of the test forms were significantly correlated with the ones obtained in other reading comprehension measures and with the results obtained in oral reading fluency, vocabulary and working memory tests. Evidence suggests that the test forms are valid measures of reading comprehension. © 2016 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
Apparatus and methods for memory using in-plane polarization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Junwei; Chang, Kai; Ji, Shuai-Hua
A memory device includes a semiconductor layer with an in-plane polarization component switchable between a first direction and a second direction. A writing electrode is employed to apply a writing voltage to the semiconductor layer to change the in-plane polarization component between the first direction and the second direction. A reading electrode is employed to apply a reading voltage to the semiconductor layer to measure a tunneling current substantially perpendicular to the polarization direction of the in-plane polarization component. The directions of the reading voltage and the writing voltage are substantially perpendicular to each other. Therefore, the reading process ismore » non-destructive. Thin films (e.g., one unit cell thick) of ferroelectric material can be used in the memory device to increase the miniaturization of the device.« less
Aerosol monitoring during carbon nanofiber production: mobile direct-reading sampling.
Evans, Douglas E; Ku, Bon Ki; Birch, M Eileen; Dunn, Kevin H
2010-07-01
Detailed investigations were conducted at a facility that manufactures and processes carbon nanofibers (CNFs). Presented research summarizes the direct-reading monitoring aspects of the study. A mobile aerosol sampling platform, equipped with an aerosol instrument array, was used to characterize emissions at different locations within the facility. Particle number, respirable mass, active surface area, and photoelectric response were monitored with a condensation particle counter (CPC), a photometer, a diffusion charger, and a photoelectric aerosol sensor, respectively. CO and CO(2) were additionally monitored. Combined simultaneous monitoring of these metrics can be utilized to determine source and relative contribution of airborne particles (CNFs and others) within a workplace. Elevated particle number concentrations, up to 1.15 x 10(6) cm(-3), were found within the facility but were not due to CNFs. Ultrafine particle emissions, released during thermal treatment of CNFs, were primarily responsible. In contrast, transient increases in respirable particle mass concentration, with a maximum of 1.1 mg m(-3), were due to CNF release through uncontrolled transfer and bagging. Of the applied metrics, our findings suggest that particle mass was probably the most useful and practical metric for monitoring CNF emissions in this facility. Through chemical means, CNFs may be selectively distinguished from other workplace contaminants (Birch et al., in preparation), and for direct-reading monitoring applications, the photometer was found to provide a reasonable estimate of respirable CNF mass concentration. Particle size distribution measurements were conducted with an electrical low-pressure impactor and a fast particle size spectrometer. Results suggest that the dominant CNF mode by particle number lies between 200 and 250 nm for both aerodynamic and mobility equivalent diameters. Significant emissions of CO were also evident in this facility. Exposure control recommendations were described for processes as required.
Aerosol Monitoring during Carbon Nanofiber Production: Mobile Direct-Reading Sampling
Evans, Douglas E.; Ku, Bon Ki; Birch, M. Eileen; Dunn, Kevin H.
2010-01-01
Detailed investigations were conducted at a facility that manufactures and processes carbon nanofibers (CNFs). Presented research summarizes the direct-reading monitoring aspects of the study. A mobile aerosol sampling platform, equipped with an aerosol instrument array, was used to characterize emissions at different locations within the facility. Particle number, respirable mass, active surface area, and photoelectric response were monitored with a condensation particle counter (CPC), a photometer, a diffusion charger, and a photoelectric aerosol sensor, respectively. CO and CO2 were additionally monitored. Combined simultaneous monitoring of these metrics can be utilized to determine source and relative contribution of airborne particles (CNFs and others) within a workplace. Elevated particle number concentrations, up to 1.15 × 106 cm−3, were found within the facility but were not due to CNFs. Ultrafine particle emissions, released during thermal treatment of CNFs, were primarily responsible. In contrast, transient increases in respirable particle mass concentration, with a maximum of 1.1 mg m−3, were due to CNF release through uncontrolled transfer and bagging. Of the applied metrics, our findings suggest that particle mass was probably the most useful and practical metric for monitoring CNF emissions in this facility. Through chemical means, CNFs may be selectively distinguished from other workplace contaminants (Birch et al., in preparation), and for direct-reading monitoring applications, the photometer was found to provide a reasonable estimate of respirable CNF mass concentration. Particle size distribution measurements were conducted with an electrical low-pressure impactor and a fast particle size spectrometer. Results suggest that the dominant CNF mode by particle number lies between 200 and 250 nm for both aerodynamic and mobility equivalent diameters. Significant emissions of CO were also evident in this facility. Exposure control recommendations were described for processes as required. PMID:20447936
Enhancement of MS2D Bartington point measurement of soil magnetic susceptibility
NASA Astrophysics Data System (ADS)
Fabijańczyk, Piotr; Zawadzki, Jarosław
2015-04-01
Field magnetometry is fast method used to assess the potential soil pollution. The most popular device used to measure the soil magnetic susceptibility on the soil surface is a MS2D Bartington. Single reading using MS2D device of soil magnetic susceptibility is low time-consuming but often characterized by considerable errors related to the instrument or environmental and lithogenic factors. Typically, in order to calculate the reliable average value of soil magnetic susceptibility, a series of MS2D readings is performed in the sample point. As it was analyzed previously, such methodology makes it possible to significantly reduce the nugget effect of the variograms of soil magnetic susceptibility that is related to the micro-scale variance and measurement errors. The goal of this study was to optimize the process of taking a series of MS2D readings, whose average value constitutes a single measurement, in order to take into account micro-scale variations of soil magnetic susceptibility in proper determination of this parameter. This was done using statistical and geostatistical analyses. The analyses were performed using field MS2D measurements that were carried out in the study area located in the direct vicinity of the Katowice agglomeration. At 150 sample points 10 MS2D readings of soil magnetic susceptibility were taken. Using this data set, series of experimental variograms were calculated and modeled. Firstly, using single random MS2D reading for each sample point, and next using the data set increased by adding one more MS2D reading, until their number reached 10. The parameters of variogram: nugget effect, sill and range of correlation were used to determine the most suitable number of MS2D readings at sample point. The distributions of soil magnetic susceptibility at sample point were also analyzed in order to determine adequate number of readings enabling to calculate reliable average soil magnetic susceptibility. The research leading to these results has received funding from the Polish-Norwegian Research Programme operated by the National Centre for Research and Development under the Norwegian Financial Mechanism 2009-2014 in the frame of Project IMPACT - Contract No Pol-Nor/199338/45/2013. References: Zawadzki J., Magiera T., Fabijańczyk P., 2007. The influence of forest stand and organic horizon development on soil surface measurement of magnetic susceptibility. Polish Journal of Soil Science, XL(2), 113-124 Zawadzki J., Fabijańczyk P., Magiera T., Strzyszcz Z., 2010. Study of litter influence on magnetic susceptibility measurements of urban forest topsoils using the MS2D sensor. Environmental Earth Sciences, 61(2), 223-230.
Development of Low-Cost Instrumentation for Single Point Autofluorescence Lifetime Measurements.
Lagarto, João; Hares, Jonathan D; Dunsby, Christopher; French, Paul M W
2017-09-01
Autofluorescence lifetime measurements, which can provide label-free readouts in biological tissues, contrasting e.g. different types and states of tissue matrix components and different cellular metabolites, may have significant clinical potential for diagnosis and to provide surgical guidance. However, the cost of the instrumentation typically used currently presents a barrier to wider implementation. We describe a low-cost single point time-resolved autofluorescence instrument, exploiting modulated laser diodes for excitation and FPGA-based circuitry for detection, together with a custom constant fraction discriminator. Its temporal accuracy is compared against a "gold-standard" instrument incorporating commercial TCSPC circuitry by resolving the fluorescence decays of reference fluorophores presenting single and double exponential decay profiles. To illustrate the potential to read out intrinsic contrast in tissue, we present preliminary measurements of autofluorescence lifetime measurements of biological tissues ex vivo. We believe that the lower cost of this instrument could enhance the potential of autofluorescence lifetime metrology for clinical deployment and commercial development.
ERIC Educational Resources Information Center
Lencioni, Gina M.
2013-01-01
The purpose of this study was to investigate the effects of explicit direct instruction and cooperative learning on reading comprehension in fourth grade students. A quasi-experimental design was used. There were six cognitive and three affective measures used to collect quantitative data. Cognitive measures included California State Test scores,…
Portable instrument for inspecting irradiated nuclear fuel assemblies
Nicholson, Nicholas; Dowdy, Edward J.; Holt, David M.; Stump, Jr., Charles J.
1985-01-01
A portable instrument for measuring induced Cerenkov radiation associated with irradiated nuclear fuel assemblies in a water-filled storage pond is disclosed. The instrument includes a photomultiplier tube and an image intensifier which are operable in parallel and simultaneously by means of a field lens assembly and an associated beam splitter. The image intensifier permits an operator to aim and focus the apparatus on a submerged fuel assembly. Once the instrument is aimed and focused, an illumination reading can be obtained with the photomultiplier tube. The instrument includes a lens cap with a carbon-14/phosphor light source for calibrating the apparatus in the field.
Reading Aloud to Children: Benefits and Implications for Acquiring Literacy Before Schooling Begins.
Massaro, Dominic W
2017-01-01
Extensive experience in written language might provide children the opportunity to learn to read in the same manner they learn spoken language. One potential type of written language immersion is reading aloud to children, which is additionally valuable because the vocabulary in picture books is richer and more extensive than that found in child-directed speech. This study continues a comparison between these 2 communication media by evaluating their relative linguistic and cognitive complexity. Although reading grade level has been used only to assess the complexity of written language, it was also applied to both child-directed and adult-directed speech. Five measures of reading grade level gave an average grade level of 4.2 for picture books, 1.9 for child-directed speech, and 3.0 for adult-directed speech. The language in picture books is more challenging than that found in both child-directed and adult-directed speech. It is proposed that this difference between written and spoken language is the formal versus informal genre of their occurrence rather than their text or oral medium. The value of reading books aloud therefore exposes children to a linguistic and cognitive complexity not typically found in speech to children.
Revalidation of the Selection Instrument for Flight Training
2017-07-01
AACog) composite, as measured by the following SIFT subscales: o Mechanical Comprehension Test (MCT) o Math Skills Test (MST) o Reading...applied mechanical science. varies/ 15 minutes MST Math Skills Test—Assesses the examinee’s computational skill and mathematical aptitude...3.36 2.11 .03 1.01 Mechanical Comprehension 463 -1.95 3.58 .01 0.92 Math Skills 463 -2.59 2.87 .06 0.82 Reading Comprehension 463 -2.51 2.93 .52
Hand-Held Ultrasonic Instrument for Reading Matrix Symbols
NASA Technical Reports Server (NTRS)
Schramm, Harry F.; Kula, John P.; Gurney, John W.; Lior, Ephraim D.
2008-01-01
A hand-held instrument that would include an ultrasonic camera has been proposed as an efficient means of reading matrix symbols. The proposed instrument could be operated without mechanical raster scanning. All electronic functions from excitation of ultrasonic pulses through final digital processing for decoding matrix symbols would be performed by dedicated circuitry within the single, compact instrument housing.
How logical reasoning mediates the relation between lexical quality and reading comprehension.
Segers, Eliane; Verhoeven, Ludo
The present study aimed to examine the role of logical reasoning in the relation between lexical quality and reading comprehension in 146 fourth grade Dutch children. We assessed their standardized reading comprehension measure, along with their decoding efficiency and vocabulary as measures of lexical quality, syllogistic reasoning as measure of (verbal) logical reasoning, and nonverbal reasoning as a control measure. Syllogistic reasoning was divided into a measure tapping basic, coherence inferencing skill using logical syllogisms, and a measure tapping elaborative inferencing skill using indeterminate syllogisms. Results showed that both types of syllogisms partly mediated the relation between lexical quality and reading comprehension, but also had a unique additional effect on reading comprehension. The indirect effect of lexical quality on reading comprehension via syllogisms was driven by vocabulary knowledge. It is concluded that measures of syllogistic reasoning account for higher-order thinking processes that are needed to make inferences in reading comprehension. The role of lexical quality appears to be pivotal in explaining the variation in reading comprehension both directly and indirectly via syllogistic reasoning.
Academic and Recreational Reading Motivation of Teacher Candidates
ERIC Educational Resources Information Center
Lancellot, Michael
2017-01-01
The purpose of this mixed methods study was to determine relationships among teacher candidates' academic and recreational reading motivation. This study utilized a previously designed, reliable, and valid instrument called the Adult Reading Motivation Scale with permission from Schutte and Malouff (2007). The instrument included a pool of 50…
Jesus, Gilmar Mercês de; Assis, Maria Alice Altenburg de; Kupek, Emil; Dias, Lizziane Andrade
2017-01-01
The quality control of data entry in computerized questionnaires is an important step in the validation of new instruments. The study assessed the consistency of recorded weight and height on the Food Intake and Physical Activity of School Children (Web-CAAFE) between repeated measures and against directly measured data. Students from the 2nd to the 5th grade (n = 390) had their weight and height directly measured and then filled out the Web-CAAFE. A subsample (n = 92) filled out the Web-CAAFE twice, three hours apart. The analysis included hierarchical linear regression, mixed linear regression model, to evaluate the bias, and intraclass correlation coefficient (ICC), to assess consistency. Univariate linear regression assessed the effect of gender, reading/writing performance, and computer/internet use and possession on residuals of fixed and random effects. The Web-CAAFE showed high values of ICC between repeated measures (body weight = 0.996, height = 0.937, body mass index - BMI = 0.972), and regarding the checked measures (body weight = 0.962, height = 0.882, BMI = 0.828). The difference between means of body weight, height, and BMI directly measured and recorded was 208 g, -2 mm, and 0.238 kg/m², respectively, indicating slight BMI underestimation due to underestimation of weight and overestimation of height. This trend was related to body weight and age. Height and weight data entered in the Web-CAAFE by children were highly correlated with direct measurements and with the repeated entry. The bias found was similar to validation studies of self-reported weight and height in comparison to direct measurements.
Factor Structure and Validation of a Set of Readiness Measures.
ERIC Educational Resources Information Center
Kaufman, Maurice; Lynch, Mervin
A study was undertaken to identify the factor structure of a battery of readiness measures and to demonstrate the concurrent and predictive validity of one instrument in that battery--the Pre-Reading Screening Procedures (PSP). Concurrent validity was determined by examining the correlation of the PSP with the Metropolitan Readiness Test (MRT),…
Shi, Jingjin; Chen, Fei'er; Cai, Yunfei; Fan, Shichen; Cai, Jing; Chen, Renjie; Kan, Haidong; Lu, Yihan; Zhao, Zhuohui
2017-01-01
Portable direct-reading instruments by light-scattering method are increasingly used in airborne fine particulate matter (PM2.5) monitoring. However, there are limited calibration studies on such instruments by applying the gravimetric method as reference method in field tests. An 8-month sampling was performed and 96 pairs of PM2.5 data by both the gravimetric method and the simultaneous light-scattering real-time monitoring (QT-50) were obtained from July, 2015 to February, 2016 in Shanghai. Temperature and relative humidity (RH) were recorded. Mann-Whitney U nonparametric test and Spearman correlation were used to investigate the differences between the two measurements. Multiple linear regression (MLR) model was applied to set up the calibration model for the light-scattering device. The average PM2.5 concentration (median) was 48.1μg/m3 (min-max 10.4-95.8μg/m3) by the gravimetric method and 58.1μg/m3 (19.2-315.9μg/m3) by the light-scattering method, respectively. By time trend analyses, they were significantly correlated with each other (Spearman correlation coefficient 0.889, P<0.01). By MLR, the calibration model for the light-scattering instrument was Y(calibrated) = 57.45 + 0.47 × X(the QT - 50 measurements) - 0.53 × RH - 0.41 × Temp with both RH and temperature adjusted. The 10-fold cross-validation R2 and the root mean squared error of the calibration model were 0.79 and 11.43 μg/m3, respectively. Light-scattering measurements of PM2.5 by QT-50 instrument overestimated the concentration levels and were affected by temperature and RH. The calibration model for QT-50 instrument was firstly set up against the gravimetric method with temperature and RH adjusted.
Shi, Jingjin; Chen, Fei’er; Cai, Yunfei; Fan, Shichen; Cai, Jing; Chen, Renjie; Kan, Haidong; Lu, Yihan
2017-01-01
Background Portable direct-reading instruments by light-scattering method are increasingly used in airborne fine particulate matter (PM2.5) monitoring. However, there are limited calibration studies on such instruments by applying the gravimetric method as reference method in field tests. Methods An 8-month sampling was performed and 96 pairs of PM2.5 data by both the gravimetric method and the simultaneous light-scattering real-time monitoring (QT-50) were obtained from July, 2015 to February, 2016 in Shanghai. Temperature and relative humidity (RH) were recorded. Mann-Whitney U nonparametric test and Spearman correlation were used to investigate the differences between the two measurements. Multiple linear regression (MLR) model was applied to set up the calibration model for the light-scattering device. Results The average PM2.5 concentration (median) was 48.1μg/m3 (min-max 10.4–95.8μg/m3) by the gravimetric method and 58.1μg/m3 (19.2–315.9μg/m3) by the light-scattering method, respectively. By time trend analyses, they were significantly correlated with each other (Spearman correlation coefficient 0.889, P<0.01). By MLR, the calibration model for the light-scattering instrument was Y(calibrated) = 57.45 + 0.47 × X(the QT – 50 measurements) – 0.53 × RH – 0.41 × Temp with both RH and temperature adjusted. The 10-fold cross-validation R2 and the root mean squared error of the calibration model were 0.79 and 11.43 μg/m3, respectively. Conclusion Light-scattering measurements of PM2.5 by QT-50 instrument overestimated the concentration levels and were affected by temperature and RH. The calibration model for QT-50 instrument was firstly set up against the gravimetric method with temperature and RH adjusted. PMID:29121101
Comparing Single-Point and Multi-point Calibration Methods in Modulated DSC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Buskirk, Caleb Griffith
2017-06-14
Heat capacity measurements for High Density Polyethylene (HDPE) and Ultra-high Molecular Weight Polyethylene (UHMWPE) were performed using Modulated Differential Scanning Calorimetry (mDSC) over a wide temperature range, -70 to 115 °C, with a TA Instruments Q2000 mDSC. The default calibration method for this instrument involves measuring the heat capacity of a sapphire standard at a single temperature near the middle of the temperature range of interest. However, this method often fails for temperature ranges that exceed a 50 °C interval, likely because of drift or non-linearity in the instrument's heat capacity readings over time or over the temperature range. Therefore,more » in this study a method was developed to calibrate the instrument using multiple temperatures and the same sapphire standard.« less
46 CFR 162.050-33 - Bilge alarm: Design specification.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., however, onboard testing in accordance with the manufacturer's operating instructions is permitted for the purposes of checking instrument drift and repeatability of the instrument reading, as well as the ability to re-zero the instrument. The accuracy of the readings must at all times remain within the limits...
Teacher Need-Structure and Instructional Preference in Reading: A Pilot Study.
ERIC Educational Resources Information Center
Duncan, Patricia H.
Thirty-one experienced teachers enrolled in graduate reading courses served as subjects in a study conducted to determine whether simple instruments could be developed to assess teacher need structure, frequency of teacher behaviors related to reading, and the relationship between the two. A 25-item instrument was developed based on Abraham…
FTIR instrumentation to monitor vapors from Shuttle tile waterproofing materials
NASA Technical Reports Server (NTRS)
Mattson, C. B.; Schwindt, C. J.
1995-01-01
The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.
DOE Office of Scientific and Technical Information (OSTI.GOV)
PIERSON, R.M.
1999-10-27
This document provides the technical basis for use of remote reading capabilities with radiological control instruments at River Protection Project facilities. The purpose of this document is to evaluate applications of remote reading capabilities with Radiological Control instrumentation to allow continuous monitoring of radiation dose rates at River Protection Project (RPP) facilities. In addition this document provides a technical basis and implementing guidelines for remote monitoring of dose rates and their potential contribution to maintaining radiation exposures ALARA.
Front-end electronics for the LZ experiment
NASA Astrophysics Data System (ADS)
Morad, James; LZ Collaboration
2016-03-01
LZ is a second generation direct dark matter detection experiment with 5.6 tonnes of liquid xenon active target, which will be instrumented as a two-phase time projection chamber (TPC). The peripheral xenon outside the active TPC (``skin'') will also be instrumented. In addition, there will be a liquid scintillator based outer veto surrounding the main cryostat. All of these systems will be read out using photomultiplier tubes. I will present the designs for front-end electronics for all these systems, which have been optimized for shaping times, gains, and low noise. Preliminary results from prototype boards will also be presented.
Testing sugar maple sap for sweetness with a refractometer
H. Clay Smith; George M. Keiser
1971-01-01
We studied the consistency of refractometer sugar readings as influenced by sap evaporation, temperature, and the drying, cleaning, and calibration of the instrument. From the study results, we suggest field procedures for using the refractometer to insure reliable measurements.
Field gamma-ray spectrometer GS256: measurements stability
NASA Astrophysics Data System (ADS)
Mojzeš, Andrej
2009-01-01
The stability of in situ readings of the portable gamma-ray spectrometer GS256 during the field season of 2006 was studied. The instrument is an impulse detector of gamma rays based on NaI(Tl) 3" × 3" scintillation unit and 256-channel spectral analyzer which allows simultaneous assessment of up to 8 radioisotopes in rocks. It is commonly used in surface geophysical survey for the measurement of natural 40K, 238U and 232Th but also artificial 137Cs quantities. The statistical evaluation is given of both repeated measurements - in the laboratory and at several field control points in different survey areas. The variability of values shows both the instrument stability and also the relative influence of some meteorological factors, mainly rainfalls. The analysis shows an acceptable level of instrument measurements stability, the necessity to avoid measurement under unfavourable meteorological conditions and to keep detailed field book information about time, position and work conditions.
Development of a surface topography instrument for automotive textured steel plate
NASA Astrophysics Data System (ADS)
Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang
2010-08-01
The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.
Kraus, Nina; Slater, Jessica; Thompson, Elaine C.; Hornickel, Jane; Strait, Dana L.; Nicol, Trent; White-Schwoch, Travis
2014-01-01
The young nervous system is primed for sensory learning, facilitating the acquisition of language and communication skills. Social and linguistic impoverishment can limit these learning opportunities, eventually leading to language-related challenges such as poor reading. Music training offers a promising auditory learning strategy by directing attention to meaningful acoustic elements of the soundscape. In light of evidence that music training improves auditory skills and their neural substrates, there are increasing efforts to enact community-based programs to provide music instruction to at-risk children. Harmony Project is a community foundation that has provided free music instruction to over 1000 children from Los Angeles gang-reduction zones over the past decade. We conducted an independent evaluation of biological effects of participating in Harmony Project by following a cohort of children for 1 year. Here we focus on a comparison between students who actively engaged with sound through instrumental music training vs. students who took music appreciation classes. All children began with an introductory music appreciation class, but midway through the year half of the children transitioned to the instrumental training. After the year of training, the children who actively engaged with sound through instrumental music training had faster and more robust neural processing of speech than the children who stayed in the music appreciation class, observed in neural responses to a speech sound /d/. The neurophysiological measures found to be enhanced in the instrumentally-trained children have been previously linked to reading ability, suggesting a gain in neural processes important for literacy stemming from active auditory learning. Despite intrinsic constraints on our study imposed by a community setting, these findings speak to the potential of active engagement with sound (i.e., music-making) to engender experience-dependent neuroplasticity and may inform the development of strategies for auditory learning. PMID:25414631
Kraus, Nina; Slater, Jessica; Thompson, Elaine C; Hornickel, Jane; Strait, Dana L; Nicol, Trent; White-Schwoch, Travis
2014-01-01
The young nervous system is primed for sensory learning, facilitating the acquisition of language and communication skills. Social and linguistic impoverishment can limit these learning opportunities, eventually leading to language-related challenges such as poor reading. Music training offers a promising auditory learning strategy by directing attention to meaningful acoustic elements of the soundscape. In light of evidence that music training improves auditory skills and their neural substrates, there are increasing efforts to enact community-based programs to provide music instruction to at-risk children. Harmony Project is a community foundation that has provided free music instruction to over 1000 children from Los Angeles gang-reduction zones over the past decade. We conducted an independent evaluation of biological effects of participating in Harmony Project by following a cohort of children for 1 year. Here we focus on a comparison between students who actively engaged with sound through instrumental music training vs. students who took music appreciation classes. All children began with an introductory music appreciation class, but midway through the year half of the children transitioned to the instrumental training. After the year of training, the children who actively engaged with sound through instrumental music training had faster and more robust neural processing of speech than the children who stayed in the music appreciation class, observed in neural responses to a speech sound /d/. The neurophysiological measures found to be enhanced in the instrumentally-trained children have been previously linked to reading ability, suggesting a gain in neural processes important for literacy stemming from active auditory learning. Despite intrinsic constraints on our study imposed by a community setting, these findings speak to the potential of active engagement with sound (i.e., music-making) to engender experience-dependent neuroplasticity and may inform the development of strategies for auditory learning.
78 FR 21044 - Amendment of Class D and Class E Airspace; Reading, PA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
...This action amends Class D and Class E Airspace at Reading, PA, as the SHAPP OM navigation aid has been decommissioned, requiring the modification of Standard Instrument Approach Procedures (SIAPs) at Reading Regional/Carl A. Spaatz Field. This action enhances the safety and management of Instrument Flight Rules (IFR) operations at the airport.
Effect of Color-Coded Notation on Music Achievement of Elementary Instrumental Students.
ERIC Educational Resources Information Center
Rogers, George L.
1991-01-01
Presents results of a study of color-coded notation to teach music reading to instrumental students. Finds no clear evidence that color-coded notation enhances achievement on performing by memory, sight-reading, or note naming. Suggests that some students depended on the color-coding and were unable to read uncolored notation well. (DK)
ERIC Educational Resources Information Center
Bauske, Ellen M.; Fuhrman, Nicholas E.; Martinez-Espinoza, Alfredo D.; Orellana, Rolando
2013-01-01
Landscape work is dangerous. In the Southeast, Hispanic workers predominate in landscape industries. The incidence of functional illiteracy in this group of workers is high. A pictorial knowledge-based evaluation instrument was developed to measure the effectiveness of the trainings. No reading skills were required to take the evaluation. The…
ERIC Educational Resources Information Center
Crews, Ruthellen; Ahrens, Maurice R.
Numerous studies have been devoted to determining the interrelationships of listening to other language arts. Most of these studies have been focused on the effects of listening on reading; most also assume that listening ability can be measured and that effective measurement instruments exist. Even though the listening component of the language…
ERIC Educational Resources Information Center
Fischer, Ronald G.; Fischer, Jerome M.
2006-01-01
Based on theories of emotional intelligence, adult education, psychology of reading, and emotions and literature, this study was designed to develop and validate the Affective Response to Literature Survey (ARLS), a psychological instrument used to measure an emotional response to literature. Initially, 27 items were generated by a review of…
Building Trades. Block II. Foundations.
ERIC Educational Resources Information Center
Texas A and M Univ., College Station. Vocational Instructional Services.
Twelve informational lessons and eleven manipulative lessons are provided on foundations as applied to the building trades. Informational lessons cover land measurements; blueprint reading; level instruments; building and site planning; building site preparation; laying out building lines; soil preparation and special evacuation; concrete forms;…
Barak, Alan V; Elder, Peggy; Fraser, Ivich
2011-02-01
Ash (Fraxinus spp.) logs, infested with fully developed, cold-acclimated larval and prepupal emerald ash borer, Agrilus planipennis Fairmaire (Coleoptera: Buprestidae), were fumigated with methyl bromide (MeBr) at 4.4 and 10.0 degrees C for 24 h. Concentrations X time dosages of MeBr obtained were 1579 and 1273 g-h/m3 (24-h exposure) at 4.4 and 10.0 degrees C after applied doses of 112 and 96 g/m3, respectively. MeBr concentrations were simultaneously measured with a ContainIR infrared monitor and Fumiscope thermal conductivity meter calibrated for MeBr to measure the effect of CO2 on Fumiscope concentration readings compared with the infrared (IR) instrument. The presence of CO2 caused false high MeBr readings. With the thermal conductivity meter, CO2 measured 11.36 g/m3 MeBr per 1% CO2 in clean air, whereas the gas-specific infrared ContainIR instrument measured 9.55% CO2 as 4.2 g/m3 MeBr (0.44 g/m3 per 1% CO2). The IR instrument was 0.4% as sensitive to CO2 as the thermal conductivity meter. After aeration, fumigated and control logs were held for 8 wk to capture emerging beetles. No A. planipennis adults emerged from any of the fumigated logs, whereas 262 emerged from control logs (139 and 123/m2 at 4.4 and 10.0 degrees C, respectively). An effective fumigation dose and minimum periodic MeBr concentrations are proposed. The use of a CO2 scrubber in conjunction with nonspecific thermal conductivity instruments is necessary to more accurately measure MeBr concentrations.
NASA Technical Reports Server (NTRS)
Heath, Donald F.; Ahmad, Zia
2001-01-01
In the early 1990s a series of surface-based direct sun and zenith sky measurements of total column ozone were made with SBUV/2 flight models and the SSBUV Space Shuttle instrument in Boulder, Colorado which were compared with NOAA Dobson Instrument direct sun observations and TOMS instrument overpass observations of column ozone. These early measurements led to the investigation of the accuracy of derived total column ozone amounts and aerosol optical depths from zenith sky observations. Following the development and availability of radiometrically stable IAD narrow band interference filter and nitrided silicon photodiodes a simple compact multifilter spectroradiometer was developed which can be used as a calibration transfer standard spectroradiometer (CTSS) or as a surface based instrument remote sensing instruments for measurements of total column ozone and aerosol optical depths. The total column ozone derived from zenith sky observations agrees with Dobson direct sun AD double wavelength pair measurements and with TOMS overpass ozone amounts within uncertainties of about 1%. When used as a calibration transfer standard spectroradiometer the multifilter spectroradiometer appears to be capable of establishing instrument radiometric calibration uncertainties of the order of 1% or less relative to national standards laboratory radiometric standards.
Early grade curriculum-based reading measures for students with intellectual disability.
Hill, David R; Lemons, Christopher J
2015-12-01
The purpose of this study was to extend previous research on the use of curriculum-based measurement (CBM) for students with intellectual disability by having 19 special education teachers monitor weekly reading progress of 38 students with intellectual disability for approximately 15 weeks and examining whether students exhibited gains on the progress monitoring measures. In addition to the weekly CBM, teachers reported the type and duration of daily reading instruction. Data were analyzed to explore relationships between CBM performance and reading instruction. Our results indicate that teachers are capable of administering and scoring CBM on a weekly basis and that CBM does capture reading growth for some students with intellectual disability. Correlations between CBM performance and a teacher report of skills taught during reading instruction indicate that teachers may be differentiating instruction based on students' reading ability. Directions for future research as well as limitations of the study are discussed. © The Author(s) 2015.
Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps.
Wong, Jessica X H; Li, Xiaochun; Liu, Frank S F; Yu, Hua-Zhong
2015-06-30
The desire to develop new point-of-care (POC) diagnostic tools has led to the adaptation of smartphones to tackle limitations in state-of-the-art instrumentation and centralized laboratory facilities. Today's smartphones possess the computer-like ability to image and process data using mobile apps; barcode scanners are one such type of apps. We demonstrate herein that a diagnostic assay can be performed by patterning immunoassay strips in a bona fide barcode format such that after target binding and signal enhancement, the linear barcode can be read directly with a standard smartphone app. Quantitative analysis can then be performed based on the grayscale intensities with a customized mobile app. This novel diagnostic concept has been validated for a real-world application, i.e., the detection of human chorionic gonadotropin, a pregnancy hormone. With the possibility of multiplex detection, the barcode assay protocol promises to boost POC diagnosis research by the direct adaptation of mobile devices and apps.
Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps
Wong, Jessica X. H.; Li, Xiaochun; Liu, Frank S. F.; Yu, Hua-Zhong
2015-01-01
The desire to develop new point-of-care (POC) diagnostic tools has led to the adaptation of smartphones to tackle limitations in state-of-the-art instrumentation and centralized laboratory facilities. Today’s smartphones possess the computer-like ability to image and process data using mobile apps; barcode scanners are one such type of apps. We demonstrate herein that a diagnostic assay can be performed by patterning immunoassay strips in a bona fide barcode format such that after target binding and signal enhancement, the linear barcode can be read directly with a standard smartphone app. Quantitative analysis can then be performed based on the grayscale intensities with a customized mobile app. This novel diagnostic concept has been validated for a real-world application, i.e., the detection of human chorionic gonadotropin, a pregnancy hormone. With the possibility of multiplex detection, the barcode assay protocol promises to boost POC diagnosis research by the direct adaptation of mobile devices and apps. PMID:26122608
Direct Reading of Bona Fide Barcode Assays for Diagnostics with Smartphone Apps
NASA Astrophysics Data System (ADS)
Wong, Jessica X. H.; Li, Xiaochun; Liu, Frank S. F.; Yu, Hua-Zhong
2015-06-01
The desire to develop new point-of-care (POC) diagnostic tools has led to the adaptation of smartphones to tackle limitations in state-of-the-art instrumentation and centralized laboratory facilities. Today’s smartphones possess the computer-like ability to image and process data using mobile apps; barcode scanners are one such type of apps. We demonstrate herein that a diagnostic assay can be performed by patterning immunoassay strips in a bona fide barcode format such that after target binding and signal enhancement, the linear barcode can be read directly with a standard smartphone app. Quantitative analysis can then be performed based on the grayscale intensities with a customized mobile app. This novel diagnostic concept has been validated for a real-world application, i.e., the detection of human chorionic gonadotropin, a pregnancy hormone. With the possibility of multiplex detection, the barcode assay protocol promises to boost POC diagnosis research by the direct adaptation of mobile devices and apps.
Separating the influences of prereading skills on early word and nonword reading.
Shapiro, Laura R; Carroll, Julia M; Solity, Jonathan E
2013-10-01
The essential first step for a beginning reader is to learn to match printed forms to phonological representations. For a new word, this is an effortful process where each grapheme must be translated individually (serial decoding). The role of phonological awareness in developing a decoding strategy is well known. We examined whether beginning readers recruit different skills depending on the nature of the words being read (familiar words vs. nonwords). Print knowledge, phoneme and rhyme awareness, rapid automatized naming (RAN), phonological short-term memory (STM), nonverbal reasoning, vocabulary, auditory skills, and visual attention were measured in 392 prereaders 4 and 5 years of age. Word and nonword reading were measured 9 months later. We used structural equation modeling to examine the skills-reading relationship and modeled correlations between our two reading outcomes and among all prereading skills. We found that a broad range of skills were associated with reading outcomes: early print knowledge, phonological STM, phoneme awareness and RAN. Whereas all of these skills were directly predictive of nonword reading, early print knowledge was the only direct predictor of word reading. Our findings suggest that beginning readers draw most heavily on their existing print knowledge to read familiar words. Copyright © 2013 Elsevier Inc. All rights reserved.
A proposed new handbook for the Federal Emergency Management Agency: Radiation safety in shelters
NASA Astrophysics Data System (ADS)
Haaland, C. M.
1981-09-01
A proposed replacement for the portion of the current Handbook for Radiological Monitoring that deals with protection of people in shelters from radiation from fallout resulting from nuclear war is presented. Basic information at a high school level is given on how to detect nuclear radiation, how to find and improve the safest places in a shelter, the necessity for and how to keep records on individual radiation exposures, and how to minimize exposures. Several procedures are introduced, some of which are based more on theoretical considerations than on actual experiments. These procedures include: (1) the method of time averaging radiation readings taken with one instrument in different locations of a large shelter while fallout is coming down and radiation levels ar climbing too rapidly for direct comparison of readings to determine the safest location; (2) the method of using one's own body to obtain directionality in radiation readings taken with a standard Civil Defense survey meter; (3) the method of using mutual shielding to reduce the average radiation exposure to shelter occupants; and (4) the ratio method for estimating radiation levels in hazardous areas.
A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read out
NASA Astrophysics Data System (ADS)
Branchini, P.; Ceradini, F.; Corradi, G.; Di Micco, B.; Passeri, A.
2009-12-01
The construction and tests performed on a smal prototype of lead-scintillating fiber calorimeter instrumented with multianode photomultipliers are reported. The prototype is 15 cm wide, 15 radiation lenghts deep and is made of 200 layers of 50 cm long fibers. One side of the calorimeter has been instrumented with an array of 3 × 5 multianode R8900-M16 Hamamatsu photomultipliers, each segmented with a matrix of 4 × 4 anodes. The read-out granularity is 240 pixels 11 × 11 mm 2 reading about 64 fibers each. They are interfaced to the 6 × 6 mm 2 pixelled photocade with truncated pyramid light guides made of BC-800 plastic, UV transparent. Moreover each photomultiplier provides also the OR information of the last 12 dynodes. This information can be useful for trigger purposes. The response of the individual anodes, their relative gain and cross-talk has been measured with a 404 nm picosecond laser illuminating only a few fibers on the opposite side of the read-out. We also present first results of the calorimeter response to cosmic rays and electron beam data collected at BTF facility in Frascati.
Executive functioning predicts reading, mathematics, and theory of mind during the elementary years.
Cantin, Rachelle H; Gnaedinger, Emily K; Gallaway, Kristin C; Hesson-McInnis, Matthew S; Hund, Alycia M
2016-06-01
The goal of this study was to specify how executive functioning components predict reading, mathematics, and theory of mind performance during the elementary years. A sample of 93 7- to 10-year-old children completed measures of working memory, inhibition, flexibility, reading, mathematics, and theory of mind. Path analysis revealed that all three executive functioning components (working memory, inhibition, and flexibility) mediated age differences in reading comprehension, whereas age predicted mathematics and theory of mind directly. In addition, reading mediated the influence of executive functioning components on mathematics and theory of mind, except that flexibility also predicted mathematics directly. These findings provide important details about the development of executive functioning, reading, mathematics, and theory of mind during the elementary years. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Wilkes, Sam T.; Blackbourn, Joe M.
This project attempts to refine the Zones of Indifference Instrument, (included in appendix) that measures zones of indifference of teachers to typical directives issued by administrators. As a result of the original validation study, a 78-item, two-factor instrument was developed. These two factors explained 52 percent of the variance. The…
Evaluation of the Delta-T SPN1 radiometer for the measurement of solar irradiance components
NASA Astrophysics Data System (ADS)
Estelles, Victor; Serrano, David; Segura, Sara; Wood, John; Webb, Nick; Utrillas, Maria Pilar
2016-04-01
In this study we analyse the performance of an SPN1 radiometer built by Delta-T Devices Ltd. to retrieve global solar irradiance at ground and its components (diffuse, direct) in comparison with measurements from two Kipp&Zonen CMP21 radiometers and a Kipp&Zonen CHP1 pirheliometer, mounted on an active Solys-2 suntracker at the Burjassot site (Valencia, Spain) using data acquired every minute during years 2013 - 2015. The measurement site is close to sea level (60 m a.s.l.), near the Mediterranean coast (10 km) and within the metropolitan area of Valencia City (over 1.500.000 inhabitants). The SPN1 is an inexpensive and versatile instrument for the measurement of the three components of the solar radiation without any mobile part and without any need to azimuthally align the instrument to track the sun (http://www.delta-t.co.uk). The three components of the solar radiation are estimated from a combination of measurements performed by 7 different miniature thermopiles. The SPN1 pyranometer measures the irradiance between 400 and 2700 nm, and the nominal uncertainty for the individual readings is about 8% ± 10 W/m2 (5% for the daily averages). The pyranometer Kipp&Zonen CMP21 model is a secondary standard for the measurement of broadband solar global irradiance in horizontal planes. Two ventilated CMP21 are used for the measurement of the global and diffuse irradiances. The expected total daily uncertainty of the radiometer is estimated to be 2%. The pirheliometer Kipp&Zonen CHP1 is designed for the measurement of the direct irradiance. The principles are similar to the CMP21 pyranometer. The results of the comparison show that the global irradiance from the SPN1 compares very well with the CMP21, with absolute RMSD and MBD differences below the combined uncertainties (15 W/m2 and -5.4 W/m2, respectively; relative RMSD of 3.1%). Both datasets are very well correlated, with a correlation coefficient higher than 0.997 and a slope and intercept very close to 1 and 0, respectively. The diffuse and direct irradiances do not compare as well as the global irradiance, although the deviations are below or close to the combined uncertainties. The diffuse irradiances have a RMSD and MBD of 15 W/m2 and 12 W/m2, similar to the global irradiance; the direct irradiance RMSD and MBD are 57 W/m2 and -44 W/m2. Both cases have a relative RMSD about 7.7-18%. Linearity is lower but still high (R=0.96). In conclusion, the SPN1 radiometer is a compact, robust and easy to maintain instrument that provides good results for the different solar irradiance components.
Classroom Correlates of Neurological "Soft Signs".
ERIC Educational Resources Information Center
Hartlage, Patricia L.; Hartlage, Lawrence C.
This study investigated the relationships between 19 neurological abnormalities in school children and measures of school performance in reading, math, and nonacademic classroom behaviors. The sample of 45 children was given a standardized achievement test and the Draw-a-Person instrument to obtain academic variables. Nonacademic behaviors…
Urine specific gravity measurement: reagent strip versus refractometer.
Brandon, C A
1994-01-01
To compare the results of urinalysis screenings for specific gravity (SG) using the reagent strip and the refractometer. United Hospital, Grand Forks, North Dakota. United Hospital is a 384-bed teaching hospital. PRODUCT COMPARISON: The Ames Multistix 10 SG reagent strip (Miles, Inc., Elkhart, IN 46515) was compared with the TS Meter (Leica, Inc., Deerfield, IL 60015). The degree of correlation between the results produced by each method. The percentage of difference between the means of the direct strip readings and the refractometer readings was 9.68%. The percentage of difference between the means of the adjusted strip readings and the refractometer readings was 22.58%, which was significantly different. When the direct strip readings and the refractometer readings were plotted together on a graph, the points were widely scattered; this fact, and a correlation coefficient of 0.725, suggest that random error occurred in both methods. Analysis of the slope and intercept of the correlation indicated systematic error. The reagent strip method of measuring SG is accurate only in a narrow range of "average" values, and should not be used as the basis for medical diagnoses.
Sun, Xinying; Yang, Shuaishuai; Fisher, Edwin B; Shi, Yuhui; Wang, Yanling; Zeng, Qingqi; Ji, Ying; Chang, Chun; Du, Weijing
2014-01-01
This study aimed to explain the relationships among health literacy, health behavior, and health status, using a newly developed skills-based measure of health literacy regarding respiratory infectious diseases. This instrument was designed to measure individuals' reading, understanding, and calculating ability, as well as their oral communication and Internet-based information-seeking abilities. A pilot survey was conducted with 489 residents in Beijing, China, to test the reliability and validity of the new measure. Next, a larger study with 3,222 residents in three cities with multistage stratified cluster sampling was implemented to validate a latent variable model (goodness of fit index=0.918, root mean square residual=0.076). In this model higher educational attainment (β=0.356) and more health knowledge (β=0.306) were positively and directly associated with greater health literacy skill, while age was negatively associated with it (β=-0.341). Age (β=0.201) and health knowledge (β=0.246) had positive and direct relationship with health behavior, which was, in turn, positively associated with health status (β=0.209). The results illustrate the complex relationships among these constructs and should be considered when developing respiratory intervention strategies to promote health behavior and health status.
Using Reading Times and Eye-Movements to Measure Cognitive Engagement
ERIC Educational Resources Information Center
Miller, Brian W.
2015-01-01
Self-paced reading and eye-tracking can be used to measure microlevel student engagement during science instruction. These methods imply a definition of engagement as the quantity and quality of mental resources directed at an object and the emotions and behaviors entailed. This definition is theoretically supported by models of reading…
Measuring the Reader Self-Perceptions of Adolescents: Introducing the RSPS2
ERIC Educational Resources Information Center
Henk, William A.; Marinak, Barbara A.; Melnick, Steven A.
2013-01-01
This paper introduces a new affective instrument for assessing the reader self-perceptions of students in grades seven through ten. The Reader Self-Perception Scale 2 (RSPS2) builds upon its predecessor, the RSPS, a tool that measures the reading efficacy beliefs of children in grades four through six. New items were created for the RSPS2 to…
Vanasse, A.; Courteau, J.
2001-01-01
OBJECTIVE: To assess the precision and integrity of all aneroid and mercury sphygmomanometers regularly used by family physicians practising outside hospitals. DESIGN: Cross-sectional study. SETTING: Private medical clinics and local community health centres in Bas-Saint-Laurent, Qué. PARTICIPANTS: A total of 151 of the 166 physicians in this administrative region. MAIN OUTCOME MEASURES: Precision of the mercury sphygmomanometers was measured using the difference between a reading in the absence of pressure and level 0. Precision of the aneroid sphygmomanometers was measured using variations at pressures of 140 mm Hg and 90 mm Hg compared with those on a calibrated mercury sphygmomanometer. Integrity of sphygmomanometers, arm cuffs, and inflating bulbs was also assessed. RESULTS: In all, 258 sphygmomanometers met the inclusion criteria (111 mercury sphygmomanometers and 147 aneroid sphygmomanometers). Discrepancies of > or = 4 mm Hg were found in 15.5% of these instruments (12.6% and 17.7% of the mercury and aneroid sphygmomanometers, respectively). In 31.0% of the instruments (52.3% and 15.0% of the mercury and aneroid sphygmomanometers, respectively), one component was malfunctioning. CONCLUSION: Sphygmomanometers that measure patients' blood pressure inaccurately could result in an incorrect diagnosis of hypertension or in a normal blood pressure reading in a hypertensive patient. PMID:11228028
Alvey, James; Palmer, Simon; Otter, Simon
2012-01-01
Measuring the outcome of surgical intervention is an integral part of modern-day healthcare provision. The increasing requirement to monitor patient-reported outcomes highlights the need for patients to be able to read and understand health outcomes questionnaires. The present study compared the readability of 2 commonly used, validated, foot surgery outcome questionnaires (the Foot Health Status Questionnaire and the Manchester-Oxford Foot Questionnaire) using the Flesch Reading Ease score and the Flesch-Kincaid grade level score. The Manchester-Oxford Foot Questionnaire had a significantly greater (p < .003) score for reading ease and a significantly lower reading grade score (p < .005) than the Foot Health Status Questionnaire. These findings suggest the Manchester-Oxford Foot Questionnaire is a more suitable instrument in terms of readability and comprehension for a greater proportion of the population undergoing hallux valgus surgery. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Aeronautic Instruments. Section II : Altitude Instruments
NASA Technical Reports Server (NTRS)
Mears, A H; Henrickson, H B; Brombacher, W G
1923-01-01
This report is Section two of a series of reports on aeronautic instruments (Technical Report nos. 125 to 132, inclusive). This section discusses briefly barometric altitude determinations, and describes in detail the principal types of altimeters and barographs used in aeronautics during the recent war. This is followed by a discussion of performance requirements for such instruments and an account of the methods of testing developed by the Bureau of Standards. The report concludes with a brief account of the results of recent investigations. For accurate measurements of altitude, reference must also be made to thermometer readings of atmospheric temperature, since the altitude is not fixed by atmospheric pressure alone. This matter is discussed in connection with barometric altitude determination.
CCAM: A novel millimeter-wave instrument using a close-packed TES bolometer array
NASA Astrophysics Data System (ADS)
Lau, Judy M.
This thesis describes CCAM, an instrument designed to map the Cosmic Microwave Background (CMB), and also presents some of the initial measurements made with CCAM on the Atacama Cosmology Telescope (ACT). CCAM uses a CCD-like camera of millimeter-wave TES bolometers. It employs new detector technology, read-out electronics, cold re-imaging optics, and cryogenics to obtain high sensitivity CMB anisotropy measurements. The free-standing 8×32 close-packed array of pop- up TES detectors is the first of its kind to observe the sky at 145 GHz. We present the design of the receiver including the antireflection coated silicon lens re-imaging system, construction and optimization of the pulse tube/ sorption refrigerator cryogenic system, as well as the technology developed to integrate eight 1×32 TES columns and accompanying read-out electronics in to an array of 256 millimeter-wave detectors into a focal plane area of 3.5 cm 2. The performance of the detectors and optics prior to deployment at the ACT site in Chile are reported as well as preliminary performance results of the instrument when optically paired with the ACT telescope in the summer of 2007. Here, we also report on the feasibility of the TES detector array to measure polarization when coupled to a rotating birefringent sapphire half wave plate and wire-grid polarizer.
NASA Astrophysics Data System (ADS)
Baumgardner, D.; Brenguier, J. L.; Bucholtz, A.; Coe, H.; DeMott, P.; Garrett, T. J.; Gayet, J. F.; Hermann, M.; Heymsfield, A.; Korolev, A.; Krämer, M.; Petzold, A.; Strapp, W.; Pilewskie, P.; Taylor, J.; Twohy, C.; Wendisch, M.; Bachalo, W.; Chuang, P.
2011-10-01
An overview is presented of airborne systems for in situ measurements of aerosol particles, clouds and radiation that are currently in use on research aircraft around the world. Description of the technology is at a level sufficient for introducing the basic principles of operation and an extensive list of references for further reading is given. A number of newer instruments that implement emerging technology are described and the review concludes with a description of some of the most important measurement challenges that remain. This overview is a synthesis of material from a reference book that is currently in preparation and that will be published in 2012 by Wiley.
Butler, Kenneth R; Minor, Deborah S; Benghuzzi, Hamed A; Tucci, Michelle
2010-01-01
The objective of this study was to evaluate terminal digit preference in blood pressure (BP) measurements taken from a sample of clinics at a large academic health sciences center. We hypothesized that terminal digit preference would occur more frequently in BP measurements taken with manual mercury sphygmomanometry compared to those obtained with semi-automated instruments. A total of 1,393 BP measures were obtained in 16 ambulatory and inpatient sites by personnel using both mercury (n=1,286) and semi-automated (n=107) devices For the semi-automated devices, a trained observer repeated the patients BP following American Heart Association recommendations using a similar device with a known calibration history. At least two recorded systolic and diastolic blood pressures (average of two or more readings for each) were obtained for all manual mercury readings. Data were evaluated using descriptive statistics and Chi square as appropriate (SPSS software, 17.0). Overall, zero and other terminal digit preference was observed more frequently in systolic (?2 = 883.21, df = 9, p < 0.001) and diastolic readings (?2 = 1076.77, df = 9, p < 0.001) from manual instruments, while all end digits obtained by clinic staff using semi-automated devices were more evenly distributed (?2 = 8.23, df = 9, p = 0.511 for systolic and ?2 = 10.48, df = 9, p = 0.313 for diastolic). In addition to zero digit bias in mercury readings, even numbers were reported with significantly higher frequency than odd numbers. There was no detectable digit preference observed when examining semi-automated measurements by clinic staff or device type for either systolic or diastolic BP measures. These findings demonstrate that terminal digit preference was more likely to occur with manual mercury sphygmomanometry. This phenomenon was most likely the result of mercury column graduation in 2 mm Hg increments producing a higher than expected frequency of even digits.
How To Control Color Appearance With Instrumentation
NASA Astrophysics Data System (ADS)
Burns, Margaret E.
1980-05-01
Colorimetry, as defined by the International Commission on Illumination, is the measurement of colors, made possible by the properties of the eye and based on a set of conventions. Instrumentation for measuring object color, therefore, must be based on a human observer. The intent is to design an instrument that in effect responds as a person would, so that research development, production control and quality control areas have some means of assessing the acceptability of the appearance of a product. Investigations of a human observer's psychological response to color, and the manner in which visual observations are made, give the instrument designer and manufacturer data necessary to answer two questions: a. How can we put numbers (instrument read-out) on a perception that occurs in the brain of the observer? b. What can we learn from examination of a visual observing situation that will guide us in our design of an instrumental simulation of this situation? Involving as it does our own daily, almost unconscious, practice of making judgments concerning the things we see, the design and manufacture of color measurement instruments is an exceedingly interesting field. The advances being made concurrently today in research concerning human color vision and in optical and electronic technology will make possible increasingly useful instrumentation for quality control of product color.
NASA Technical Reports Server (NTRS)
Tabacco, Mary Beth; Zhou, Quan
1995-01-01
pH-sensitive chromophoric reagents immobilized in porous optical fibers. Optoelectronic instrumentation system measures acidity or alkalinity of aqueous nutrient solution. Includes one or more optrodes, which are optical-fiber chemical sensors, in sense, analogous to electrodes but not subject to some of spurious effects distorting readings taken by pH electrodes. Concept of optrodes also described in "Ethylene-Vapor Optrodes" (KSC-11579). pH optrode sensor head, with lead-in and lead-out optical fibers, convenient for monitoring solutions located away from supporting electronic equipment.
Flight Motor Set 360L003 (STS-29R)
NASA Technical Reports Server (NTRS)
Riehr, Glen A.
1989-01-01
The redesigned solid rocket motor (RSRM) flight set 360L003 was launched on March 13, 1989 as part of NASA space shuttle mission STS-29R. As was the case with flight sets 360L001 and 360L002 (STS-26R and STS-27R), both motors (360L003A and 360L003B) performed in an excellent manner. Evaluation of the ground environment instrumentation measurements verified thermal model analysis data and showed agreement with predicted environmental effects. The right-hand aft field joint primary heater failed during the countdown; the secondary heater was activated and performed as designed. All other field joint heaters and aft skirt thermal conditioning systems had no anomalies. Shuttle thermal imager infrared readings compared favorably with measured ground environment instrumentation data. No thermal launch commit criteria violations occurred at any time. Evaluation of the development flight instrumentation showed exceptional propulsion performance. All ballistic parameters closely matched the predicted values and were well within the required specification levels. Girth and biaxial strain gage measurements compared closely with corresponding gages on previous flight motors, static tests, and with preflight predictions. Adequate safety factors were verified. (Some ignition transient spiking was noted in a few girth gages; the spiking was determined not to be representative of actual case behavior, but an instrumentation phenomena.) The accelerometers again measured high vibration amplitude levels during the ignition transient and the reentry Max Q phases. Postflight inspection showed that all combustion gas was contained by the insulation in the field and case-to-nozzle joints. No anomalous insulation erosion patterns were found, and the seals that did directly contain motor pressure showed no heat effects, erosion, or blowby. All anomalies identified were a result of splashdown damage, with the exception of fretting in the case field joint interference (nonsealing) surfaces and a prelaunch field joint heater failure. The disposition of all anomalies and the complete results are reported.
Reliability and Validity of Eye Movement Measures of Children's Reading
ERIC Educational Resources Information Center
Foster, Tori E.; Ardoin, Scott P.; Binder, Katherine S.
2018-01-01
Although strong claims have been made regarding the educational utility of eye tracking, such statements seem somewhat unfounded in the absence of clear evidence regarding the technical adequacy of eye movement (EM) data. Past studies have yielded direct and indirect evidence concerning the utility of EMs as measures of reading, but recent…
40 CFR 98.84 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... by direct weight measurement using the same plant instruments used for accounting purposes, such as... be determined quarterly by direct weight measurement using the same plant instruments used for accounting purposes, such as weigh hoppers, truck weigh scales, or belt weigh feeders. (f) The quantity of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lachut, J. S.
Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride didmore » not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.« less
ERIC Educational Resources Information Center
Mora-Whitehurst, Rina
2013-01-01
This article focuses on elementary principals as instructional leaders, as well as public school initiatives and educational accountability in the United States. It presents the methodology, instrumentation, measures of academic achievement in Florida, data collection, and processing procedures. Finally, it presents data analysis, results of the…
Machine Shop Practice, 13-2. Military Curriculum Materials for Vocational and Technical Education.
ERIC Educational Resources Information Center
Army Ordnance Center and School, Aberdeen Proving Ground, MD.
This military-developed text consists of self-instructional materials dealing with the basic tools and equipment used in metalworking shops. Covered in the individual lessons are the following topics: materials and processes; shop mathematics; blueprint reading and sketching; handtools, measuring instruments, and basic metalworking machines;…
Tile Test: A Hands-On Approach for Assessing Phonics in the Early Grades
ERIC Educational Resources Information Center
Norman, Kimberly A.; Calfee, Robert C.
2004-01-01
An instrument for assessing young students' understanding of the English orthographic system is presented. The Tile Test measures understanding of phoneme awareness, letter-sound correspondences, decoding and spelling of words, sight-word reading, and the application of decoding and spelling in sentences. Metalinguistic questions embedded within…
GreenNet: A Global Ground-Based Network of Instruments Measuring Greenhouse Gases in the Atmosphere
NASA Astrophysics Data System (ADS)
Floyd, M.; Grunberg, M.; Wilson, E. L.
2017-12-01
Climate change is the most important crisis of our lifetime. For policy makers to take action to combat the effects of climate change, they will need definitive proof that it is occurring globally. We have developed a low-cost ground instrument - a portable miniaturized laser heterodyne radiometer (mini-LHR) - capable of measuring concentrations of two of the most potent anthropogenic greenhouse gases, CO2 and methane, in columns in the atmosphere. They work by combining sunlight that has undergone absorption by gases with light from a laser. This combined light is detected by a photoreciever and a radio frequency beat signal is produced. From this beat signal, concentrations of these gases throughout the atmospheric column can be determined. A network of mini-LHR instruments in locations around the world will give us the data necessary to significantly reduce uncertainty in greenhouse gas sinks and sources contributing to climate change. Each instrument takes one reading per minute while the sun is up. With a goal to establish up to 500 instrument sites, the estimated total data per day will likely exceed 1GB. Every piece of data must be sorted as it comes in to determine whether it is a good or bad reading. The goal of the citizen science project is to collaborate with citizen scientists enrolled with Zooniverse.org to cycle through our data and help sort it, while also learning about the mini-LHR, greenhouse gases and climate change. This data will be used to construct an algorithm to automatically sort data that relies on statistical analyses of the previously sorted data.
Frasure, Jamey
2008-01-01
This paper is a report of a systematic review describing instruments used to measure nurses' attitudes towards research utilization. Researchers need to have the tools to measure nurses' attitudes. However, limited literature critically analyses instruments and the concepts that comprise nurses' attitudes towards research utilization. A search of the literature from 1982 to 2007 was performed using the Cumulative Index to Nursing and Allied Health Literature, Health and Psychosocial Instruments, PubMed and MEDLINE data bases. The search terms were nursing research, research utilization, instruments, and nurses' attitudes. A total of 186 sources were identified, of which 25 were reviewed. Fourteen instruments met the criteria for in-depth critical analysis of psychometric properties and concepts, and were included in the final review. Each instrument item was judged to be relevant to direct, indirect, persuasive and overall research utilization as defined by Estabrooks. Instruments were arranged from the strongest to the weakest reliability of the subscales to determine the instrument with the strongest psychometric properties. Indirect and overall research utilization was measured by all of the instruments. Ten instruments measured direct research utilization and nine instruments measured persuasive research utilization. The Research Utilization in Nursing Survey by Estabrooks, as adapted by Kenny, was an instrument with strong psychometric properties measuring all four concepts of nurses' attitudes towards using and participating in research and was clinically feasible. Many published instruments are available for use by nurse researchers to measure nurses' attitude towards research utilization, but only one has been subjected to rigorous testing: the Research Utilization in Nursing Survey by Estabrooks.
Counter tube window and X-ray fluorescence analyzer study
NASA Technical Reports Server (NTRS)
Hertel, R.; Holm, M.
1973-01-01
A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.
A Binary Offset Effect in CCD Readout and Its Impact on Astronomical Data
NASA Astrophysics Data System (ADS)
Boone, K.; Aldering, G.; Copin, Y.; Dixon, S.; Domagalski, R. S.; Gangler, E.; Pecontal, E.; Perlmutter, S.
2018-06-01
We have discovered an anomalous behavior of CCD readout electronics that affects their use in many astronomical applications. An offset in the digitization of the CCD output voltage that depends on the binary encoding of one pixel is added to pixels that are read out one, two, and/or three pixels later. One result of this effect is the introduction of a differential offset in the background when comparing regions with and without flux from science targets. Conventional data reduction methods do not correct for this offset. We find this effect in 16 of 22 instruments investigated, covering a variety of telescopes and many different front-end electronics systems. The affected instruments include LRIS and DEIMOS on the Keck telescopes, WFC3 UVIS and STIS on HST, MegaCam on CFHT, SNIFS on the UH88 telescope, GMOS on the Gemini telescopes, HSC on Subaru, and FORS on VLT. The amplitude of the introduced offset is up to 4.5 ADU per pixel, and it is not directly proportional to the measured ADU level. We have developed a model that can be used to detect this “binary offset effect” in data, and correct for it. Understanding how data are affected and applying a correction for the effect is essential for precise astronomical measurements.
Santos, Juliana Feitosa dos; Souza, Ana Paula Ramos de; Seligman, Lilian
2013-01-01
To analyze the possible relationships between high sound pressure levels in the classroom and performance in the use of lexical and phonological routes in reading and writing. This consisted on a quantitative and exploratory study. The following measures were carried out: acoustic measurement, using the dosimeter, visual inspection of the external auditory canal, tonal audiometry thresholds, speech recognition tests and acoustic immittance; instrument for evaluation of reading and writing of isolated words. The non-parametric χ² test and Fisher's exact test were used for data analysis. The results of acoustic measurements in 4 schools in Santa Maria divided the sample of 87 children of third and fourth years of primary school, aged 8 to 10 years, in 2 groups. The 1st group was exposed to sound levels higher than 80 dB(A) (Study group) and the 2nd group at levels lower than 80 dB(A) (Control group). Higher prevalence of correct answers in reading and writing of nonwords, reading irregular words and frequency effect were observed. Predominance of correct answers in the writing of irregular words was observed in the Control group. For the Study group, a higher number of type errors neologism in reading and writing were observed, especially regarding the writing of nonwords and the extension effect; fewer errors of lexicalization type and verbal paragraphy in writing were observed. In assessing the reading and writing skills, children in the Study group exposed to high noise levels had poorer performance in the use of lexical and phonological routes, both in reading and in writing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lauf, R.J.; Bible, D.W.; Sohns, C.W.
1999-10-19
Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.
Lauf, Robert J.; Bible, Don W.; Sohns, Carl W.
1999-01-01
Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.
A Self-Report Measure of Physical Activity
ERIC Educational Resources Information Center
Siegel, Donald
2005-01-01
There are multiple approaches to measuring physical activity. Among these are direct observation, electronic monitoring, direct and indirect calorimetry, and self-report instruments. Self-report instruments are the most practical and cost effective option for use with a large group. In a study by Motl, Dishman, Dowda, and Pate (2004), two groups…
NASA Astrophysics Data System (ADS)
Laskar, S.; Bordoloi, S.
2016-01-01
This paper presents an instrumentation system to measure the degradation in lubricating oil using a bare, tapered and bent multi-mode optical fiber (BTBMOF) sensor probe and a temperature probe. The sensor system consists of (i) a bare, tapered and bent multi-mode optical fiber (BTBMOF) as optical sensor along with a laser source and a LDR (Light Dependent Resistor) as detector (ii) a temperature sensor (iii) a ATmega microcontroller based data acquisition system and (iv) a trained ANN for processing and calibration. The BTBMOF sensor and the temperature sensor are used to provide the measure of refractive index (RI) and the temperature of a lubricating oil sample. A microcontroller based instrumentation system with trained ANN algorithm has been developed to determine the degradation of the lubricating oil sample by sampling the readings of the optical fiber sensor, and the temperature sensor.
Measurement of hydraulic conductivity of unsaturated soils with thermocouple psychometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, D.E.
1982-11-01
A method of measuring the hydraulic conductivity of unsaturated soil using the instantaneous profile method with psychometric probes to measure water potential is developed and described. Soil is compacted into cylindrical tubes, and the tubes are sealed and instrumented with thermocouple psychrometers. The soil is moistened or dried from one end of the tube. Psychrometers are read periodically. Hydraulic conductivity is computed from the psychrometer readings and the appropriate moisture characteristic curve for the soil and then plotted as a function of water potential, water content, or degree of saturation. Hydraulic conductivities of six soils were measured at water potentialsmore » as low as -80 bar. The measured hydraulic conductivities and moisture characteristic curves were used along with the known boundary flux in a computer program to calculate the final water content profiles. Computed and measured final water content profiles agreed tolerably well.« less
Wind-instrument reflection function measurements in the time domain.
Keefe, D H
1996-04-01
Theoretical and computational analyses of wind-instrument sound production in the time domain have emerged as useful tools for understanding musical instrument acoustics, yet there exist few experimental measurements of the air-column response directly in the time domain. A new experimental, time-domain technique is proposed to measure the reflection function response of woodwind and brass-instrument air columns. This response is defined at the location of sound regeneration in the mouthpiece or double reed. A probe assembly comprised of an acoustic source and microphone is inserted directly into the air column entryway using a foam plug to ensure a leak-free fit. An initial calibration phase involves measurements on a single cylindrical tube of known dimensions. Measurements are presented on an alto saxophone and euphonium. The technique has promise for testing any musical instrument air columns using a single probe assembly and foam plugs over a range of diameters typical of air-column entryways.
Remote possibly hazardous content container sampling device
Volz, David L.
1998-01-01
The present invention relates to an apparatus capable of sampling enclosed containers, where the contents of the container is unknown. The invention includes a compressed air device capable of supplying air pressure, device for controlling the amount of air pressure applied, a pneumatic valve, a sampling device having a hollow, sampling insertion needle suspended therein and device to communicate fluid flow between the container and a containment vessel, pump or direct reading instrument.
Retell as an Indicator of Reading Comprehension
Reed, Deborah K.; Vaughn, Sharon
2011-01-01
The purpose of this narrative synthesis is to determine the reliability and validity of retell protocols for assessing reading comprehension of students in grades K–12. Fifty-four studies were systematically coded for data related to the administration protocol, scoring procedures, and technical adequacy of the retell component. Retell was moderately correlated with standardized measures of reading comprehension and, with older students, had a lower correlation with decoding and fluency. Literal information was retold more frequently than inferential, and students with learning disabilities or reading difficulties needed more supports to demonstrate adequate recall. Great variability was shown in the prompting procedures, but scoring methods were more consistent across studies. The influences of genre, background knowledge, and organizational features were often specific to particular content, texts, or students. Overall, retell has not yet demonstrated adequacy as a progress monitoring instrument. PMID:23125521
ERIC Educational Resources Information Center
Marston, Doug; And Others
Two studies were conducted to examine the efficacy of direct measurement, standardized achievement tests, and aptitude-achievement discrepancy scores in distinguishing learning disabled (LD) and nonlearning disabled (NLD) students in grades 3 to 6. For both reading (Study I) and written expression (Study II), students' scores on direct and…
On the Use of the Immediate Recall Task as a Measure of Second Language Reading Comprehension
ERIC Educational Resources Information Center
Chang, Yuh-Fang
2006-01-01
The immediate written recall task, a widely used measure of both first language (L1) and second language (L2) reading comprehension, has been advocated over traditional test methods such as multiple choice, cloze tests and open-ended questions because it is a direct and integrative assessment task. It has been, however, criticized as requiring…
NASA Astrophysics Data System (ADS)
Zuber, Ralf; Sperfeld, Peter; Riechelmann, Stefan; Nevas, Saulius; Sildoja, Meelis; Seckmeyer, Gunther
2018-04-01
A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.
NASA Technical Reports Server (NTRS)
Roder, H. M.
1974-01-01
Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.
Chavanne, Xavier; Bruère, Alain; Frangi, Jean-Pierre
2018-05-28
The article comments on claims made by Rêgo et al. about the sensor they developed to determine soil water content and its salinity via the admittance measurement of electrodes embedded in the soil. Their sensor is not based on a self-balanced bridge, as stated, but on a more common technique relying on Ohm's law. A bridge is a zero method of measurement which can provide direct voltages proportional to soil permittivity and conductivity with a high resolution. Thanks to modern electronics the method can be adapted for fast and continuous monitoring in a remote site. Because of this confusion about the different measurement techniques among available admittance or capacitance sensors, we give a succinct review of them and indicate how they compare to the two techniques under discussion. We also question the ability of Rêgo et al.'s current sensor to determine both soil water content and salinity due first to instrument biases and then to the soil complexity as a dielectric medium. In particular, the choice of sensor frequencies is crucial in the two steps. In addition, the procedure to determine and account for temperature influences on readings is not presented clearly enough. It is important to distinguish between the effect resulting from electronics sensitivity, and those that are soil-specific. The comment does not invalidate the design of the sensor, but indicates points, especially parasitic contributions, which must be dealt with to avoid major errors.
Physical activity and sedentary time in relation to academic achievement in children.
Haapala, Eero A; Väistö, Juuso; Lintu, Niina; Westgate, Kate; Ekelund, Ulf; Poikkeus, Anna-Maija; Brage, Soren; Lakka, Timo A
2017-06-01
To investigate the independent and combined associations of objectively measured moderate-to-vigorous physical activity (MVPA) and sedentary time (ST) with reading and arithmetic skills. Cross-sectional/prospective. Participants were 89 boys and 69 girls aged 6-8 years. MVPA and ST were measured using a combined heart rate and movement sensor and body fat percentage by dual-energy X-ray absorptiometry in Grade 1. Reading fluency, reading comprehension, and arithmetic skills were assessed using standardized tests in Grades 1-3. The data were analyzed using linear regression analyses and analyses of covariance with repeated measures. In boys, MVPA was directly and ST inversely associated with reading fluency in Grades 1-3 and arithmetic skills in Grade 1 (P<0.05). Higher levels of MVPA were also related to better reading comprehension in Grade 1 (P<0.05). Most of the associations of MVPA and ST with reading and arithmetic skills attenuated after mutual adjustment for MVPA or ST. Furthermore, boys with a combination of lower levels of MVPA and higher levels of ST had consistently poorer reading fluency (P=0.002) and reading comprehension (P=0.027) across Grades 1-3 than other boys. In girls, ST was directly associated with arithmetic skills in Grade 2 (P<0.05). However, this relationship of ST with arithmetic skills was no longer significant after adjustment for body fat percentage. Lower levels of MVPA and higher levels of ST and particularly their combination were related to poorer reading skills in boys. In girls, higher levels of ST were related to better arithmetic skills. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Chu, Byoung-Sun; Ngo, Thao P T; Cheng, Brian B; Dain, Stephen J
2014-07-01
The accuracy and precision of any instrument should not be taken for granted. While there is an international standard for checking focimeters, there is no report of any study on their performance. A sample set of 51 focimeters (11 brands), were used to measure the spherical power of a set of lenses and the prismatic power of two lenses complying with ISO 9342-1:2005 and other calibrated prismatic lenses and the spherical power of some grey filters. The mean measured spherical power corresponded very closely with the calibrated values; however, the spread of results was substantial and 10 focimeters did not comply with ISO 8598:1996. The measurement of prism was much more accurate and precise and all the focimeters complied easily. With the grey filters, about one-third of the focimeters either showed erratic reading or an error with the equivalent of category 4 sunglasses. On the other hand, nine focimeters had stable and accurate reading on a filter with a luminous transmittance of 0.5 per cent. These results confirm that, in common with all other measurement instruments, there is a need to ensure that a focimeter is reading accurately and precisely over the range of refractive powers and luminous transmittances. The accurate and precise performance of an automated focimeter over its working life cannot be assumed. Checking before purchase with a set of calibrated lenses and some dark sunglass tints will indicate the suitability of a focimeter. Routine checking with the calibrated lenses will inform the users if a focimeter continues to indicate accurately. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.
A photoelectric skylight polarimeter.
Hariharan, T A; Sekera, Z
1966-09-01
A photoelectric skylight polarimeter to measure directly the Stokes parameters for plane polarized light is described. The basic principle of the instrument consists in the simultaneous measurement of the intensity of light (in the chosen spectral region) transmitted by polarizers oriented in four specific directions. The main features and performance characteristics of the instrument are briefly discussed.
Correcting systematic bias and instrument measurement drift with mzRefinery
Gibbons, Bryson C.; Chambers, Matthew C.; Monroe, Matthew E.; ...
2015-08-04
Systematic bias in mass measurement adversely affects data quality and negates the advantages of high precision instruments. We introduce the mzRefinery tool into the ProteoWizard package for calibration of mass spectrometry data files. Using confident peptide spectrum matches, three different calibration methods are explored and the optimal transform function is chosen. After calibration, systematic bias is removed and the mass measurement errors are centered at zero ppm. Because it is part of the ProteoWizard package, mzRefinery can read and write a wide variety of file formats. In conclusion, we report on availability; the mzRefinery tool is part of msConvert, availablemore » with the ProteoWizard open source package at http://proteowizard.sourceforge.net/« less
NASA Technical Reports Server (NTRS)
Mann, C. W. (Inventor)
1984-01-01
A device used in the optical alignment of machinery to maintain a measuring scale in the proper position for optical readings to be taken is described. The device consists of a block containing a notch in the shape of an inverted ""v'' and a rotatable plug positioned over the centerline of notch. The block is placed on the object to be aligned, the notch allows the block to be securely placed upon flat or curved surfaces. A weighted measuring scale is inserted through plug so that it contacts the object to be aligned. The scale and plug combination can be rotated so that the scale faces an optical aligning instrument. The instrument is then used in conjunction with the scale to measure the distance of the machinery from a reference plane.
ERIC Educational Resources Information Center
Snow, Amie B.; Morris, Darrell; Perney, Jan
2018-01-01
We examined which of two instruments (Text Reading and Comprehension inventory [TRC] or a traditional informal reading inventory [IRI]) provides the more valid assessment of a primary-grade student's reading instructional level. The TRC is currently the required, benchmark reading assessment for students in grades K-3 in the state of North…
Fonseca-Reyes, Salvador; Romero-Velarde, Enrique; Torres-Gudiño, Edith; Illescas-Zarate, Daniel; Forsyth-MacQuarrie, Avril M
The level of agreement between two blood pressure (BP) reading methods, auscultatory vs oscillometric, was examined using a mercury sphygmomanometer and an electronic device in children and adolescents with different levels of obesity. The readings were compared to determine their impact on the diagnosis of pre-hypertension/hypertension. Blood pressure readings were taken in children with obesity (body mass index ≥ 95th percentile) and severe obesity (≥120% 95th percentile). Bland-Altman analysis and Intraclass Correlation Coefficient were used to determine the agreement between measurements. The mercury sphygmomanometer readings were lower than those obtained with the electronic device for both systolic and diastolic BP (P=.01 and P=.001, respectively). The mean systolic and diastolic BP differences between the oscillometric vs first mercury reading were 4.2/10.2mmHg, respectively. A large difference was observed between the BP measurement methods. The ICC showed regular to moderate reliability for the systolic BP (.595), but poor for the diastolic BP (.330). Screening using the first of three mercury measurements showed that 10.4% of the children and adolescents had BPs within the pre-hypertension/hypertension range. This was reduced to 5.2% when the mean of three mercury readings was used. Large discrepancies were observed in both the systolic and diastolic BP. These differences are not clinically acceptable as to consider the two instruments interchangeable. The electronic device readings were higher, and they overestimated the diagnosis of hypertension. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Eye position changes during reading fixations are spatially selective.
Inhoff, Albrecht W; Solomon, Matthew S; Seymour, Bradley A; Radach, Ralph
2008-03-01
Intra-fixation location changes were measured when one-line sentences written in lower or aLtErNaTiNg case were read. Intra-fixation location changes were common and their size was normally distributed except for a relatively high proportion of fixations without a discernible location change. Location changes that did occur were systematically biased toward the right when alternating case was read. Irrespective of case type, changes of the right eye were biased toward the right at the onset of sentence reading, and this spatial bias decreased as sentence reading progressed from left to right. The left eye showed a relatively stable right-directed bias. These results show that processing demands can pull the two fixated eyes in the same direction and that the response to this pull can differ for the right and left eye.
ERIC Educational Resources Information Center
Maynard, Jennifer Leigh
2012-01-01
Emphasis on regular mathematics skill assessment, intervention, and progress monitoring under the RTI model has created a need for the development of assessment instruments that are psychometrically sound, reliable, universal, and brief. Important factors to consider when developing or selecting assessments for the school environment include what…
Cathodoluminescence and Thermoluminescence of Undoped LTB and LTB:A (A = Cu, Ag, Mn)
2013-03-01
operated, tabletop instrument for thermoluminescent dosimetry (TLD) measurements seen in Figure 3-8. It reads one dosimeter per loading and...the more sophisticated Riso TL/ OSL reader that Brant used at the University of Cincinnati [9]. Figure 4-12: TL data for LTB: Ag irradiated with 5
ERIC Educational Resources Information Center
Arizona Department of Education, 2009
2009-01-01
The tables presented in this document show the Arizona Instrument to Measure Standards (AIMS) results for the past two years. Twenty-four tables show results as percent at each performance level and percent passing, as well as percent of students tested. The tables shown in this document include: (1) Mathematics Grade 3; (2) Reading Grade 3; (3)…
40 CFR 61.242-7 - Standards: Valves.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Equipment Leaks... detect leaks by the method specified in § 61.245(b) and shall comply with paragraphs (b)-(e), except as...) If an instrument reading of 10,000 ppm or greater is measured, a leak is detected. (c)(1) Any valve...
Standardized Curriculum for Machine Tool Operation/Machine Shop.
ERIC Educational Resources Information Center
Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.
Standardized vocational education course titles and core contents for two courses in Mississippi are provided: machine tool operation/machine shop I and II. The first course contains the following units: (1) orientation; (2) shop safety; (3) shop math; (4) measuring tools and instruments; (5) hand and bench tools; (6) blueprint reading; (7)…
Theory-based metrological traceability in education: A reading measurement network.
Fisher, William P; Stenner, A Jackson
2016-10-01
Huge resources are invested in metrology and standards in the natural sciences, engineering, and across a wide range of commercial technologies. Significant positive returns of human, social, environmental, and economic value on these investments have been sustained for decades. Proven methods for calibrating test and survey instruments in linear units are readily available, as are data- and theory-based methods for equating those instruments to a shared unit. Using these methods, metrological traceability is obtained in a variety of commercially available elementary and secondary English and Spanish language reading education programs in the U.S., Canada, Mexico, and Australia. Given established historical patterns, widespread routine reproduction of predicted text-based and instructional effects expressed in a common language and shared frame of reference may lead to significant developments in theory and practice. Opportunities for systematic implementations of teacher-driven lean thinking and continuous quality improvement methods may be of particular interest and value.
Solid state neutron dosimeter for space applications
NASA Technical Reports Server (NTRS)
Entine, Gerald; Nagargar, Vivek; Sharif, Daud
1990-01-01
Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.
External pressure measurement system
NASA Astrophysics Data System (ADS)
Chandler, Jon K.; Fowler, Don P.
Hydraulic systems comprise an important part of jet aircraft and their pressure needs must be checked constantly. Tests of the prototype external pressure measurement system show that it is possible to accurately convert the small expansion of tubing with pressure into a direct pressure reading without inserting a pressure gage into the piping system. The tool described in the paper is a clamp-on displacement transducer that can read pressure directly in PSI from 0 to 5000. Some limitations concerning temperature and accuracy should be remedied by additional design work. The system promises to streamline troubleshooting of all types of piping systems.
Space Technology for Palate Surgery
NASA Technical Reports Server (NTRS)
1980-01-01
University of Miami utilized NASA's spacecraft viewing technology to develop the optical profilometer provides more accurate measurements of cleft palate casts than has heretofore been possible, enabling better planning of corrective surgery. Lens like instrument electronically scans a palate cast precisely measuring its irregular contours by detecting minute differences in the intensity of a light beam reflected off the cast. Readings are computer processed and delivered to the surgeon by a teleprinter.
Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment
NASA Technical Reports Server (NTRS)
Brooker, John E.; Ruff, Gary A.
2004-01-01
The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.
Sobrado, J M; Martín-Soler, J; Martín-Gago, J A
2015-10-01
We have designed and developed an in-vacuum dust deposition system specifically conceived to simulate and study the effect of accumulation of Martian dust on the electronic instruments of scientific planetary exploration missions. We have used this device to characterize the dust effect on the UV sensor of the Rover Environmental Monitoring Station in the Mars science Laboratory mission of NASA in similar conditions to those found on Mars surface. The UV sensor includes six photodiodes for measuring the radiation in all UV wavelengths (direct incidence and reflected); it is placed on the body of Curiosity rover and it is severely affected by the dust deposited on it. Our experimental setup can help to estimate the duration of reliable reading of this instrument during operation. We have used an analogous of the Martian dust in chemical composition (magnetic species), color, and density, which has been characterized by X-ray spectroscopy. To ensure a Brownian motion of the dust during its fall and a homogeneous coverage on the instrumentation, the operating conditions of the vacuum vessel, determined by partial pressures and temperature, have to be modified to account for the different gravities of Mars with respect to Earth. We propose that our designed device and operational protocol can be of interest to test optoelectronic instrumentation affected by the opacity of dust, as can be the degradation of UV photodiodes in planetary exploration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sobrado, J. M., E-mail: sobradovj@inta.es; Martín-Soler, J.; Martín-Gago, J. A.
We have designed and developed an in-vacuum dust deposition system specifically conceived to simulate and study the effect of accumulation of Martian dust on the electronic instruments of scientific planetary exploration missions. We have used this device to characterize the dust effect on the UV sensor of the Rover Environmental Monitoring Station in the Mars science Laboratory mission of NASA in similar conditions to those found on Mars surface. The UV sensor includes six photodiodes for measuring the radiation in all UV wavelengths (direct incidence and reflected); it is placed on the body of Curiosity rover and it is severelymore » affected by the dust deposited on it. Our experimental setup can help to estimate the duration of reliable reading of this instrument during operation. We have used an analogous of the Martian dust in chemical composition (magnetic species), color, and density, which has been characterized by X-ray spectroscopy. To ensure a Brownian motion of the dust during its fall and a homogeneous coverage on the instrumentation, the operating conditions of the vacuum vessel, determined by partial pressures and temperature, have to be modified to account for the different gravities of Mars with respect to Earth. We propose that our designed device and operational protocol can be of interest to test optoelectronic instrumentation affected by the opacity of dust, as can be the degradation of UV photodiodes in planetary exploration.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, Matthew B; Niedziela, Jennifer L; Abernathy, Douglas L
The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments is not exclusive and overlaps significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems.more » We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M. B.; Abernathy, D. L.; Ehlers, G.
The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. Wemore » have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.« less
A New Instrument for the IRTF: the MIT Optical Rapid Imaging System (MORIS)
NASA Astrophysics Data System (ADS)
Gulbis, Amanda A. S.; Elliot, J. L.; Rojas, F. E.; Bus, S. J.; Rayner, J. T.; Stahlberger, W. E.; Tokunaga, A. T.; Adams, E. R.; Person, M. J.
2010-10-01
NASA's 3-m Infrared Telescope Facility (IRTF) on Mauna Kea, HI plays a leading role in obtaining planetary science observations. However, there has been no capability for high-speed, visible imaging from this telescope. Here we present a new IRTF instrument, MORIS, the MIT Optical Rapid Imaging System. MORIS is based on POETS (Portable Occultation Eclipse and Transit Systems; Souza et al., 2006, PASP, 118, 1550). Its primary component is an Andor iXon camera, a 512x512 array of 16-micron pixels with high quantum efficiency, low read noise, low dark current, and full-frame readout rates of between 3.5 Hz (6 e /pixel read noise) and 35 Hz (49 e /pixel read noise at electron-multiplying gain=1). User-selectable binning and subframing can increase the cadence to a few hundred Hz. An electron-multiplying mode can be employed for photon counting, effectively reducing the read noise to sub-electron levels at the expense of dynamic range. Data cubes, or individual frames, can be triggered to nanosecond accuracy using a GPS. MORIS is mounted on the side-facing widow of SpeX (Rayner et al. 2003, PASP, 115, 362), allowing simultaneous near-infrared and visible observations. The mounting box contains 3:1 reducing optics to produce a 60 arcsec x 60 arcsec field of view at f/12.7. It hosts a ten-slot filter wheel, with Sloan g×, r×, i×, and z×, VR, Johnson V, and long-pass red filters. We describe the instrument design, components, and measured characteristics. We report results from the first science observations, a 24 June 2008 stellar occultation by Pluto. We also discuss a recent overhaul of the optical path, performed in order to eliminate scattered light. This work is supported in part by NASA Planetary Major Equipment grant NNX07AK95G. We are indebted to the University of Hawai'i Institute for Astronomy machine shop, in particular Randy Chung, for fabricating instrument components.
Learning-related skills and academic achievement in academically at-risk first graders
Cerda, Carissa A.; Im, Myung Hee; Hughes, Jan N.
2015-01-01
Using an academically at-risk, ethnically diverse sample of 744 first-grade children, this study tested a multi-method (i.e., child performance measures, teacher ratings, and peer ratings) measurement model of learning-related skills (i.e., effortful control [EC], behavioral self-regulation [BSR], and social competence [SC]), and their shared and unique contributions to children's reading and math achievement, above the effect of demographic variables. The hypothesized correlated factor measurement model demonstrated relatively good fit, with BSR and SC correlated highly with one another and moderately with EC. When entered in separate regression equations, EC and BSR each predicted children's reading and math achievement; SC only predicted reading achievement. When considered simultaneously, neither EC, BSR, nor SC contributed independently to reading achievement; however, EC had a direct effect on math achievement and an indirect effect on reading achievement via both BSR and SC. Implications for research and early intervention efforts are discussed. PMID:25908886
Genetic and Environmental Influences on Writing and their Relations to Language and Reading
Olson, Richard K.; Hulslander, Jacqueline; Christopher, Micaela; Keenan, Janice M.; Wadsworth, Sally J.; Willcutt, Erik G.; Pennington, Bruce F.; DeFries, John C.
2011-01-01
Identical and fraternal twins (N = 540, age 8 to 18 years) were tested on three different measures of writing (Woodcock-Johnson III Tests of Achievement-Writing Samples and Writing Fluency; Handwriting Copy from the Group Diagnostic Reading and Aptitude Achievement Tests), three different language skills (Phonological Awareness, Rapid Naming, and Vocabulary), and three different reading skills (Word Recognition, Spelling, and Reading Comprehension). Substantial genetic influence was found on two of the writing measures, Writing Samples and Handwriting Copy, and all of the language and reading measures. Shared environment influences were generally not significant, except for vocabulary. Non-shared environment estimates, including measurement error, were significant for all variables. Genetic influences among the writing measures were significantly correlated (highest between the speeded measures Writing Fluency and Handwriting Copy), but there were also significant independent genetic influences between Copy and Samples and between Fluency and Samples. Genetic influences on writing were significantly correlated with genetic influences on all of the language and reading skills, but significant independent genetic influences were also found for Copy and Samples, whose genetic correlations were significantly less than 1.0 with the reading and language skills. The genetic correlations varied significantly in strength depending on the overlap between the writing, language, and reading task demands. We discuss implications of our results for education, limitations of the study, and new directions for research on writing and its relations to language and reading. PMID:21842316
A review of health-related workplace productivity loss instruments.
Lofland, Jennifer H; Pizzi, Laura; Frick, Kevin D
2004-01-01
The objective of this review was to identify health-related workplace productivity loss survey instruments, with particular emphasis on those that capture a metric suitable for direct translation into a monetary figure. A literature search using Medline, HealthSTAR, PsycINFO and Econlit databases between 1966 and 2002, and a telephone-administered survey of business leaders and researchers, were conducted to identify health-related workplace productivity measurement survey instruments. This review was conducted from the societal perspective. Each identified instrument was reviewed for the following: (i). reliability; (ii). content validity; (iii). construct validity; (iv). criterion validity; (v). productivity metric(s); (vi). instrument scoring technique; (vii). suitability for direct translation into a monetary figure; (viii). number of items; (ix). mode(s) of administration; and (x). disease state(s) in which it had been tested. Reliability and validity testing have been performed for 8 of the 11 identified surveys. Of the 11 instruments identified, six captured metrics that are suitable for direct translation into a monetary figure. Of those six, one instrument measured absenteeism, while the other five measured both absenteeism and presenteeism. All of the identified instruments except for one were available as paper, self-administered questionnaires and many were available in languages other than English. This review provides a comprehensive overview of the published, peer-reviewed survey instruments available to measure health-related workplace productivity loss. As the field of productivity measurement matures, tools may be developed that will allow researchers to accurately calculate lost productivity costs when performing cost-effectiveness and cost-benefit analyses. Using data captured by these instruments, society and healthcare decision makers will be able to make better informed decisions concerning the value of the medications, disease management and health promotion programmes that individuals receive.
Heth, Inbahl; Lavidor, Michal
2015-04-01
To better understand the contribution of the dorsal system to word reading, we explored transcranial direct current stimulation (tDCS) effects when adults with developmental dyslexia received active stimulation over the visual extrastriate area MT/V5, which is dominated by magnocellular input. Stimulation was administered in 5 sessions spread over two weeks, and reading speed and accuracy as well as reading fluency were assessed before, immediately after, and a week after the end of the treatment. A control group of adults with developmental dyslexia matched for age, gender, reading level, vocabulary and block-design WAIS-III sub-tests and reading level was exposed to the same protocol but with sham stimulation. The results revealed that active, but not sham stimulation, significantly improved reading speed and fluency. This finding suggests that the dorsal stream may play a role in efficient retrieval from the orthographic input lexicon in the lexical route. It also underscores the potential of tDCS as an intervention tool for improving reading speed, at least in adults with developmental dyslexia. Copyright © 2015 Elsevier Ltd. All rights reserved.
The Neural Substrates for Letter String Readings in The Normal and Reverse Directions: An fMRI Study
NASA Astrophysics Data System (ADS)
Ge, Sheng; Saito, Takashi; Wu, Jing-Long; Ogasawara, Jun-Ichi; Yamauchi, Shuichi; Matsunaga, Naofumi; Iramina, Keiji
In order to investigate the difference in cortical activations between reading letter strings in the normal direction and the reverse direction, an fMRI study was conducted. In this study, the cortical activations elicited by Japanese letter string reading and Chinese letter string reading were investigated. The subjects performed the normal direction reading task (read letter strings from left to right), and the reverse direction reading task (read letter strings from right to left). According to the experimental results, the activated brain regions during the normal and the reverse direction reading tasks were compared. It was found that visuospatial transformation was involved in the reverse direction reading task, while this function was not significant during the normal direction reading task. Furthermore, we found that there was no significant difference in cortical activation between Japanese and Chinese letter string readings.
Bases of Radio Direction Finding. Part 1
1977-12-22
flight toward airport, motion to the ship, that suffers calamity, and so fo tb); they are applied also for other target/purposes ( research on "he...very essemtial method for research on a number of the physical problems, connested with caRi3 9gineerinq, mainly tWo questions of the propagatior of...reading along eLa:tronechanical instrument, along cathode-ray tube, in digital signal panel. vas carried out research 3n the reasons for the errors of
Zhang, John; Toftness, Dave; Snyder, Brian; Nosco, Dennis; Balcavage, Walter; Nindl, Gabi
2004-12-01
The use of magnetic fields to treat disease has intrigued mankind since the time of the ancient Greeks. More recently it has been shown that electromagnetic field (EMF) treatment aids bone healing, and repetitive transcranial magnetic stimulation (rTMS) appears to be beneficial in treating schizophrenia and depression. Since external EMFs influence internal body processes, we hypothesized that measurement of body surface EMFs might be used to detect disease states and direct the course of subsequent therapy. However, measurement of minute body surface EMFs requires use of a sensitive and well documented magnetometer. In this study we evaluated the sensitivity and frequency response of a fluxgate magnetometer with a triaxial probe for use in detecting body surface EMF and we compared the magnetometer readings with a signal from a Toftness Sensometer, operated by an experienced clinician, in the laboratory and in a clinical setting. A Peavy Audio Amplifier and variable power output Telulex signal generator were used to develop 50 microT EMFs in a three coil Merritt coil system. A calibrated magnetometer was used to set a 60 Hz 50 microT field in the coil and an ammeter was used to measure the current required to develop the 50 microT field. At frequencies other than 60 Hz, the field strength was maintained at 50 microT by adjusting the Telulex signal output to keep the current constant. The field generated was monitored using a 10 turn coil connected to an oscilloscope. The oscilloscope reading indicated that the field strength was the same at all frequencies tested. To determine if there was a correspondence between the signals detected by a fluxgate magnetometer (FGM1) and the Toftness Sensometer both devices were placed in the Merritt coil and readings were recorded from the FGM1 and compared with the ability of a highly experienced Toftness operator to detect the 50 microT field. Subsequently, in a clinical setting, FGM1 readings made by an FGM1 technician and Sensometer readings were made by 4 Toftness Sensometer operators, having various degrees of experience with this device. Each examiner obtained instrument readings from 5 different volunteers in separate chiropractic adjusting rooms. Additionally, one of the Toftness Sensometers was equipped with an integrated fluxgate magnetometer (FGM2) and this magnetometer was used to obtain a second set of EMF readings in the clinical setting. The triaxial fluxgate magnetometer was determined to be moderately responsive to changes in magnetic field frequency below 10 Hz. At frequencies above 10 Hz the readings corresponded to that of the ambient static geofield. The practitioner operating the Toftness Sensometer was unable to detect magnetic fields at high frequencies (above 10 Hz) even at very high EMFs. The fluxgate magnetometer was shown to be essentially a DC/static magnetic field detector and like all such devices it has a limited frequency range with some low level of sensitivity at very low field frequencies. The interexaminer reliability of four Toftness practitioners using the Sensometer on 5 patients showed low to moderate correlation. The fluxgate magnetometer although highly sensitive to static (DC) EMFs has only limited sensitivity to EMFs in the range of 1 to 10 Hz and is very insensitive to frequencies above 10 Hz. In laboratory comparisons of the Sensometer and the fluxgate magnetometer there was an occasional correspondence between the two instruments in detecting magnetic fields within the Merritt coil but these occasions were not reproducible. In the clinical studies there was low to moderate agreement between the clinicians using the Sensometer to diagnosing spinal conditions and there was little if any agreement between the Sensometer and the fluxgate magnetometer in detecting EMFs emanating from the volunteers body surface.
Zhang, John; Toftness, Dave; Snyder, Brian; Nosco, Dennis; Balcavage, Walter; Nindl, Gabi
2004-01-01
Introduction The use of magnetic fields to treat disease has intrigued mankind since the time of the ancient Greeks. More recently it has been shown that electromagnetic field (EMF) treatment aids bone healing, and repetitive transcranial magnetic stimulation (rTMS) appears to be beneficial in treating schizophrenia and depression. Since external EMFs influence internal body processes, we hypothesized that measurement of body surface EMFs might be used to detect disease states and direct the course of subsequent therapy. However, measurement of minute body surface EMFs requires use of a sensitive and well documented magnetometer. In this study we evaluated the sensitivity and frequency response of a fluxgate magnetometer with a triaxial probe for use in detecting body surface EMF and we compared the magnetometer readings with a signal from a Toftness Sensometer, operated by an experienced clinician, in the laboratory and in a clinical setting. Methods A Peavy Audio Amplifier and variable power output Telulex signal generator were used to develop 50 μT EMFs in a three coil Merritt coil system. A calibrated magnetometer was used to set a 60 Hz 50 μT field in the coil and an ammeter was used to measure the current required to develop the 50 μT field. At frequencies other than 60 Hz, the field strength was maintained at 50 μT by adjusting the Telulex signal output to keep the current constant. The field generated was monitored using a 10 turn coil connected to an oscilloscope. The oscilloscope reading indicated that the field strength was the same at all frequencies tested. To determine if there was a correspondence between the signals detected by a fluxgate magnetometer (FGM1) and the Toftness Sensometer both devices were placed in the Merritt coil and readings were recorded from the FGM1 and compared with the ability of a highly experienced Toftness operator to detect the 50 μT field. Subsequently, in a clinical setting, FGM1 readings made by an FGM1 technician and Sensometer readings were made by 4 Toftness Sensometer operators, having various degrees of experience with this device. Each examiner obtained instrument readings from 5 different volunteers in separate chiropractic adjusting rooms. Additionally, one of the Toftness Sensometers was equipped with an integrated fluxgate magnetometer (FGM2) and this magnetometer was used to obtain a second set of EMF readings in the clinical setting. Results The triaxial fluxgate magnetometer was determined to be moderately responsive to changes in magnetic field frequency below 10 Hz. At frequencies above 10 Hz the readings corresponded to that of the ambient static geofield. The practitioner operating the Toftness Sensometer was unable to detect magnetic fields at high frequencies (above 10 Hz) even at very high EMFs. The fluxgate magnetometer was shown to be essentially a DC/static magnetic field detector and like all such devices it has a limited frequency range with some low level of sensitivity at very low field frequencies. The interexaminer reliability of four Toftness practitioners using the Sensometer on 5 patients showed low to moderate correlation. Conclusions The fluxgate magnetometer although highly sensitive to static (DC) EMFs has only limited sensitivity to EMFs in the range of 1 to 10 Hz and is very insensitive to frequencies above 10 Hz. In laboratory comparisons of the Sensometer and the fluxgate magnetometer there was an occasional correspondence between the two instruments in detecting magnetic fields within the Merritt coil but these occasions were not reproducible. In the clinical studies there was low to moderate agreement between the clinicians using the Sensometer to diagnosing spinal conditions and there was little if any agreement between the Sensometer and the fluxgate magnetometer in detecting EMFs emanating from the volunteers body surface. PMID:17549105
NASA Astrophysics Data System (ADS)
Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy
The FLASH instrument is based on the fluorescent method, which uses H2O molecules photodissociation at a wavelength lambda=121.6 nm (Lalpha - hydrogen emission) followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation is a hydrogen discharge lamp while the detector of OH fluorescence at 308 -316 nm is a photomultiplier run in photon counting mode. The intensity of the fluorescent light as well as the instrument readings is directly proportional to the water vapor mixing ratio under stratospheric conditions with negligible oxygen absorption. Initially designed for rocket-borne application, FLASH has evolved into a light-weight balloon sonde (FLASH-B) for measurements in the upper troposphere and stratosphere on board meteorological and small plastic balloons. This configuration has been used in over 100 soundings at numerous tropical mid-latitude and polar locations within various international field campaigns. An airborne version of FLASH instrument is successfully utilized onboard stratospheric M55-Geophysica aircraft and tropospheric airborne laboratory YAK42-Roshydromet. The hygrometer was modified for application onboard stratospheric long-duration balloons (FLASH-LDB version). This version was successfully used onboard CNES super-pressure balloon launched from SSC Esrange in March 2007 and flown during 10 days. Special design for polar long duration balloon PoGOLite was created for testing work during polar day in June 2013. Installation and measurement peculiarities as well as observational results are presented. Observations of water vapour using FLASH-B instrument, being of high quality are rather costly as the payload recovery is often complicated and most of the time impossible. Following the goal to find a cost-efficient solution, FLASH was adapted for use onboard Unmanned Aerial Vehicles (UAV). This solution was only possible thanks to compactness and light-weight (0.5 kg) of FLASH instrument. The hygrometer was installed at the nose of a small GPS-controlled glider, which was lifted by a meteorological balloon into the stratosphere and released by a remote command. GPS-based flight control guides and lands the UAV at the launch point thereby allowing multiple usage of its payload. Another sounding platform allowing for multiple usage of the FLASH instrument is a GPS-guided paraglide. The results of measurements acquired in the test flights using different types of balloon-lifted UAVs are presented.
Progress on the FDM Development at SRON: Toward 160 Pixels
NASA Astrophysics Data System (ADS)
den Hartog, R. H.; Bruijn, M. P.; Clenet, A.; Gottardi, L.; Hijmering, R.; Jackson, B. D.; van der Kuur, J.; van Leeuwen, B. J.; van der Linden, A. J.; van Loon, D.; Nieuwenhuizen, A.; Ridder, M.; van Winden, P.
2014-08-01
SRON is developing the electronic read-out for arrays of transition edge sensors using frequency domain multiplexing in combination with base-band feedback. The astronomical applications of this system are the read-out of soft X-ray micro-calorimeters in a potential instrument on the European X-ray mission-under-study Athena+ and far-IR bolometers for the Safari instrument on the Japanese mission SPICA. In this paper we demonstrate the simultaneous read-out of 38 bolometer pixels at a 12 aW/Hz dark NEP level. The stability of the read-out is assessed over 400 s. time spans. Although some 1/f noise is present, there are several bolometers for which 1/f-free read-out can be demonstrated.
Freitas, Sandra; Prieto, Gerardo; Simões, Mário R; Nogueira, Joana; Santana, Isabel; Martins, Cristina; Alves, Lara
2018-05-03
The present study aims to analyze the psychometric characteristics of the TeLPI (Irregular Words Reading Test), a Portuguese premorbid intelligence test, using the Rasch model for dichotomous items. The results reveal an overall adequacy and a good fit of values regarding both items and persons. A high variability of cognitive performance level and a good quality of the measurements were also found. The TeLPI has proved to be a unidimensional measure with reduced DIF effects. The present findings contribute to overcome an important gap in the psychometric validity of this instrument and provide good evidence of the overall psychometric validity of TeLPI results.
Sargent, M R; Sayres, D S; Smith, J B; Witinski, M; Allen, N T; Demusz, J N; Rivero, M; Tuozzolo, C; Anderson, J G
2013-07-01
We present a new instrument for the measurement of water vapor in the upper troposphere and lower stratosphere (UT∕LS), the Harvard Herriott Hygrometer (HHH). HHH employs a tunable diode near-IR laser to measure water vapor via direct absorption in a Herriott cell. The direct absorption technique provides a direct link between the depth of the observed absorption line and the measured water vapor concentration, which is calculated based on spectroscopic parameters in the HITRAN database. While several other tunable diode laser (TDL) instruments have been used to measure water vapor in the UT∕LS, HHH is set apart by its use of an optical cell an order of magnitude smaller than those of other direct absorption TDLs in operation, allowing for a more compact, lightweight instrument. HHH is also unique in its integration into a common duct with the Harvard Lyman-α hygrometer, an independent photo-fragment fluorescence instrument which has been thoroughly validated over 19 years of flight measurements. The instrument was flown for the first time in the Mid-latitude Airborne Cirrus Properties Experiment (MACPEX) on NASA's WB-57 aircraft in spring, 2011, during which it demonstrated in-flight precision of 0.1 ppmv (1 s) with 1-sigma uncertainty of 5% ± 0.7 ppmv. Since the campaign, changes to the instrument have lead to improved accuracy of 5% ± 0.2 ppmv as demonstrated in the laboratory. During MACPEX, HHH successfully measured water vapor at concentrations from 3.5 to 600 ppmv in the upper troposphere and lower stratosphere. HHH and Lyman-α, measuring independently but under the same sampling conditions, agreed on average to within 1% at water vapor mixing ratios above 20 ppmv and to within 0.3 ppmv at lower mixing ratios. HHH also agreed with a number of other in situ water vapor instruments on the WB-57 to within their stated uncertainties, and to within 0.7 ppmv at low water. This agreement constitutes a significant improvement over past in situ comparisons, in which differences of 1.5-2 ppmv were routinely observed, and demonstrates that the accuracy of HHH is consistent with other instruments which use a range of detection methods and sampling techniques.
Handheld directional reflectometer: an angular imaging device to measure BRDF and HDR in real time
NASA Astrophysics Data System (ADS)
Mattison, Phillip R.; Dombrowski, Mark S.; Lorenz, James M.; Davis, Keith J.; Mann, Harley C.; Johnson, Philip; Foos, Bryan
1998-10-01
Many applications require quantitative measurements of surface light scattering, including quality control on production lines, inspection of painted surfaces, inspection of field repairs, etc. Instruments for measuring surface scattering typically fall into two main categories, namely bidirectional reflectometers, which measure the angular distribution of scattering, and hemispherical directional reflectometers, which measure the total scattering into the hemisphere above the surface. Measurement of the bi-directional reflectance distribution function (BRDF) gives the greatest insight into how light is scattered from a surface. Measurements of BRDF, however, are typically very lengthy measurements taken by moving a source and detector to map the scattering. Since BRDF has four angular degrees of freedom, such measurements can require hours to days to complete. Instruments for measuring BRDF are also typically laboratory devices, although a field- portable bi-directional reflectometer does exist. Hemispherical directional reflectance (HDR) is a much easier measurement to make, although care must be taken to use the proper methodology when measuring at wavelengths beyond 10 micrometer, since integrating spheres (typically used to make such measurements) are very energy inefficient and lose their integrating properties at very long wavelengths. A few field- portable hemispherical directional reflectometers do exist, but typically measure HDR only at near-normal angles. Boeing Defense and Space Group and Surface Optics Corporation, under a contract from the Air Force Research Laboratory, have developed a new hand-held instrument capable of measuring both BRDF and HDR using a unique, patented angular imaging technique. A combination of an hemi-ellipsoidal mirror and an additional lens translate the angular scatter from a surface into a two-dimensional spatial distribution, which is recorded by an imaging array. This configuration fully maps the scattering from a half-hemisphere above the surface with more than 30,000 angularly-resolved points and update rates to 60 measurements per second. The instrument then computes HDR from the measured BDR. For ease of use, the instrument can also compare both the BRDF and HDR to preset limits, generating a Pass/Fail indicator for HDR and a high-acceptable-low image display of BRDF. Beam incidence elevation is variable from normal incidence ((theta) equals 0 degrees) to 5 degrees off grazing ((theta) equals 85 degrees), while scattering is measured to nearly 90 degrees off normal. Such capability is extremely important for any application requiring knowledge of surface appearance at oblique viewing angles. The current instrument operates over the range of 3 micrometer to 12 micrometer, with extension into the visible band possible.
Low-income fathers' speech to toddlers during book reading versus toy play.
Salo, Virginia C; Rowe, Meredith L; Leech, Kathryn A; Cabrera, Natasha J
2016-11-01
Fathers' child-directed speech across two contexts was examined. Father-child dyads from sixty-nine low-income families were videotaped interacting during book reading and toy play when children were 2;0. Fathers used more diverse vocabulary and asked more questions during book reading while their mean length of utterance was longer during toy play. Variation in these specific characteristics of fathers' speech that differed across contexts was also positively associated with child vocabulary skill measured on the MacArthur-Bates Communicative Development Inventory. Results are discussed in terms of how different contexts elicit specific qualities of child-directed speech that may promote language use and development.
Design Through Integration of On-Board Calibration Device with Imaging Spectroscopy Instruments
NASA Technical Reports Server (NTRS)
Stange, Michael
2012-01-01
The main purpose of the Airborne Visible and Infrared Imaging Spectroscopy (AVIRIS) project is to "identify, measure, and monitor constituents of the Earth's surface and atmosphere based on molecular absorption and particle scattering signatures." The project designs, builds, and tests various imaging spectroscopy instruments that use On-Board Calibration devices (OBC) to check the accuracy of the data collected by the spectrometers. The imaging instrument records the spectral signatures of light collected during flight. To verify the data is correct, the OBC shines light which is collected by the imaging spectrometer and compared against previous calibration data to track spectral response changes in the instrument. The spectral data has the calibration applied to it based on the readings from the OBC data in order to ensure accuracy.
Assessing Comprehension During Reading with the Reading Strategy Assessment Tool (RSAT)
Magliano, Joseph P.; Millis, Keith K.; Levinstein, Irwin
2011-01-01
Comprehension emerges as the results of inference and strategic processes that support the construction of a coherent mental model for a text. However, the vast majority of comprehension skills tests adopt a format that does not afford an assessment of these processes as they operate during reading. This study assessed the viability of the Reading Strategy Assessment Tool (RSAT), which is an automated computer-based reading assessment designed to measure readers’ comprehension and spontaneous use of reading strategies while reading texts. In the tool, readers comprehend passages one sentence at a time, and are asked either an indirect (“What are your thoughts regarding your understanding of the sentence in the context of the passage?”) or direct (e.g., why X?) question after reading each pre-selected target sentence. The answers to the indirect questions are analyzed on the extent that they contain words associated with comprehension processes. The answers to direct questions are coded for the number of content words in common with an ideal answer, which is intended to be an assessment of emerging comprehension. In the study, the RSAT approach was shown to predict measures of comprehension comparable to standardized tests. The RSAT variables were also shown to correlate with human ratings. The results of this study constitute a “proof of concept” and demonstrate that it is possible to develop a comprehension skills assessment tool that assesses both comprehension and comprehension strategies. PMID:23901332
Evaluation of mobile smartphones app as a screening tool for environmental noise monitoring.
Ibekwe, Titus S; Folorunsho, David O; Dahilo, Enoch A; Gbujie, Ibeneche O; Nwegbu, Maxwell M; Nwaorgu, Onyekwere G
2016-01-01
Noise is a global occupational and environmental health hazard with considerable social and physiological impact and, therefore, there is a need for regular measurements to boost monitoring and regulations of environmental noise levels in our communities. This necessitates a readily available, inexpensive, and easy to use noise measuring device. We aimed to test the sensitivity and validity of mobile "smart" phones for this purpose. This was a comparative analysis of a cross sectional study done between January 2014 and February 2015. Noise levels were measured simultaneously at different locations within Abuja Nigeria at day and night hours in real time environments. A sound level meter (SLM) (Extech407730 Digital Soundmeter, serial no.: 2310135, calibration no: 91037) and three smartphones (Samsung Galaxy note3, Nokia S, and Techno Phantom Z running on Android "Apps" Androidboy1) were used. Statistical calculations were done with Pearson correlation, T-test and Consistency within American National Standards Institute acceptable standard errors. Noise level readings for both daytime and night with the SLM and the mobile phones showed equivalent values. All noise level meters measured were <100dB. The daytime readings were nearly identical in six locations and the maximum difference in values between the SLM and Smartphone instruments was 3db, noted in two locations. Readings in dBA showed strong correlation (r = 0.9) within acceptable error limits for Type 2 SLM devices and no significant difference in the values (p = 0.12 & 0.58) for both day and night. Sensitivity of the instrument yielded 92.9%. The androidboy1 "app" performance in this study showed a good correlation and comparative high sensitivity to the Standard SLM (type 2 SLM device). However there is the need for further studies.
Microwave/Sonic Apparatus Measures Flow and Density in Pipe
NASA Technical Reports Server (NTRS)
Arndt, G. D.; Ngo, Phong; Carl, J. R.; Byerly, Kent A.
2004-01-01
An apparatus for measuring the rate of flow and the mass density of a liquid or slurry includes a special section of pipe instrumented with microwave and sonic sensors, and a computer that processes digitized readings taken by the sensors. The apparatus was conceived specifically for monitoring a flow of oil-well-drilling mud, but the basic principles of its design and operation are also applicable to monitoring flows of other liquids and slurries.
ERIC Educational Resources Information Center
Langstaff, Nancy
This book, intended for use by inservice teachers, preservice teachers, and parents interested in open classrooms, contains three chapters. "Beginning Reading in an Open Classroom" discusses language development, sight vocabulary, visual discrimination, auditory discrimination, directional concepts, small muscle control, and measurement of…
The New Literacies of Online Reading Comprehension: Future Directions
ERIC Educational Resources Information Center
Coiro, Julie
2012-01-01
Research in four areas has the potential to dramatically improve how practitioners address the challenges of integrating digital texts and tasks into their literacy curriculum. Advances in defining and measuring key components of online reading comprehension are rapidly emerging. In addition, instructional models, such as Internet reciprocal…
Hadden, Kristie; Prince, Latrina Y; Barnes, C Lowry
In response to an assessment of organizational health literacy practices at a major academic health center, this case study evaluated the health literacy demands of patient-reported outcome measures commonly used in orthopedic surgery practices to identify areas for improvement. A mixed-methods approach was used to analyze the readability and patient feedback of orthopedic patient-reported outcome materials. Qualitative results were derived from focus group notes, observations, recordings, and consensus documents. Results were combined to formulate recommendations for quality improvement. Readability results indicated that narrative portions of sample patient outcome tools were written within or below the recommended eighth-grade reading level (= 5.9). However, document literacy results were higher than the recommended reading level (= 9.8). Focus group results revealed that participants had consensus on 8 of 12 plain language best practices, including use of bullet lists and jargon or technical words in both instruments. Although the typical readability of both instruments was not exceedingly high, appropriate readability formula and assessment methods gave a more comprehensive assessment of true readability. In addition, participant feedback revealed the need to reduce jargon and improve formatting to lessen the health literacy demands on patients. As clinicians turn more toward patient-reported measures to assess health care quality, it is important to consider the health literacy demands that are inherent in the instruments they are given in our health systems.
Assessing Students' Metacognitive Awareness of Reading Strategies.
ERIC Educational Resources Information Center
Mokhtari, Kouider; Reichard, Carla A.
2002-01-01
Describes development and validation of a new self-report instrument, the Metacognitive Awareness of Reading Strategies Inventory, designed to assess adolescent and adult readers' metacognitive awareness and perceived use of reading strategies while reading academic materials. After a brief review of the literature, the development and validation…
40 CFR 264.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... indications of liquids dripping from the pump seal. (b)(1) If an instrument reading of 10,000 ppm or greater is measured, a leak is detected. (2) If there are indications of liquids dripping from the pump seal... each leak is detected. (d) Each pump equipped with a dual mechanical seal system that includes a...
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Bureau of Instructional Support and Community Services.
The 1999 Florida Legislature revised the laws pertaining to the assessment of students in Department of Juvenile Justice (DJJ) facilities. Revisions identified specific requirements for measuring student academic progress in the basic skill areas of reading, writing, and mathematics. Following the passage of this legislation, the Department of…
NASA Astrophysics Data System (ADS)
Burse, Mahesh; Chattopadhyay, Sabyasachi; Ramaprakash, A. N.; Sinha, Sakya; Prabhudesai, Swapnil; Punnadi, Sujit; Chordia, Pravin; Kohok, Abhay
2016-07-01
As a part of a design study for the On-Instrument Low Order Wave-front Sensor (OIWFS) for the TMT Infra-Red Imaging Spectrograph (IRIS), we recently evaluated the noise performance of a detector control system consisting of IUCAA SIDECAR DRIVE ELECRONICS CONTROLLER (ISDEC), SIDECAR ASIC and HAWAII-2RG (H2RG) MUX. To understand and improve the performance of this system to serve as a near infrared wavefront sensor, we implemented new read out modes like multiple regions of interest with differential multi-accumulate readout schemes for the HAWAII-2RG (H2RG) detector. In this system, the firmware running in SIDECAR ASIC programs the detector for ROI readout, reads the detector, processes the detector output and writes the digitized data into its internal memory. ISDEC reads the digitized data from ASIC, performs the differential multi-accumulate operations and then sends the processed data to a PC over a USB interface. A special loopback board was designed and used to measure and reduce the noise from SIDECAR ASIC DC biases2. We were able to reduce the mean r.m.s read noise of this system down to 1-2 e. for any arbitrary window frame of 4x4 size at frame rates below about 200 Hz.
47 CFR 73.1215 - Specifications for indicating instruments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... used by broadcast stations: (a) Linear scale instruments: (1) Length of scale shall not be less than 2.3 inches (5.8 cm). (2) Accuracy shall be at least 2 percent of the full scale reading. (3) The maximum rating of the meter shall be such that it does not read off scale during modulation or normal...
Developing Sight-Reading Skills on Mallet Percussion Instruments
ERIC Educational Resources Information Center
Fidyk, Steve
2009-01-01
Sight-reading while playing a mallet instrument can present serious obstacles for the developing percussionist. Many young players who have solid snare drum technique usually cite fear of playing the wrong note as the number-one hurdle to overcome in order to begin making real progress. Greg Byrne, associate director of bands at the University of…
Veenendaal, Nathalie J.; Groen, Margriet A.; Verhoeven, Ludo
2016-01-01
The purpose of this study was to examine the directionality of the relationship between text reading prosody and reading comprehension in the upper grades of primary school. We compared three theoretical possibilities: Two unidirectional relations from text reading prosody to reading comprehension and from reading comprehension to text reading prosody and a bidirectional relation between text reading prosody and reading comprehension. Further, we controlled for autoregressive effects and included decoding efficiency as a measure of general reading skill. Participants were 99 Dutch children, followed longitudinally, from fourth- to sixth-grade. Structural equation modeling showed that the bidirectional relation provided the best fitting model. In fifth-grade, text reading prosody was related to prior decoding and reading comprehension, whereas in sixth-grade, reading comprehension was related to prior text reading prosody. As such, the results suggest that the relation between text reading prosody and reading comprehension is reciprocal, but dependent on grade level. PMID:27667916
Kuo, Chung-Feng Jeffrey; Wang, Hsing-Won; Hsiao, Shang-Wun; Peng, Kai-Ching; Chou, Ying-Liang; Lai, Chun-Yu; Hsu, Chien-Tung Max
2014-01-01
Physicians clinically use laryngeal video stroboscope as an auxiliary instrument to test glottal diseases, and read vocal fold images and voice quality for diagnosis. As the position of vocal fold varies in each person, the proportion of the vocal fold size as presented in the vocal fold image is different, making it impossible to directly estimate relevant glottis physiological parameters, such as the length, area, perimeter, and opening angle of the glottis. Hence, this study designs an innovative laser projection marking module for the laryngeal video stroboscope to provide reference parameters for image scaling conversion. This innovative laser projection marking module to be installed on the laryngeal video stroboscope using laser beams to project onto the glottis plane, in order to provide reference parameters for scaling conversion of images of laryngeal video stroboscope. Copyright © 2013 Elsevier Ltd. All rights reserved.
Exposure to ammonia and acute respiratory effects in a urea fertilizer factory.
Rahman, Md Hamidur; Bråtveit, Magne; Moen, Bente E
2007-01-01
Personal exposures to ammonia and acute respiratory effects were determined in workers at a urea fertilizer factory in Bangladesh. Full-shift personal exposure to ammonia was measured using a PAC III direct reading instrument and Drager diffusion tubes. Respiratory symptoms were elicited by a questionnaire study (n = 113), and preshift and postshift lung function (FVC, FEV1, and PEFR) were tested using spirometry (n = 88). Urea plant workers had higher mean exposure to ammonia and prevalence of acute respiratory symptoms than did workers in the ammonia plant. The symptoms with highest prevalence in the urea plant were chest tightness (33%) and cough (28%). FVC and FEV1 decreased significantly across the work shift among urea plant workers. The higher level of exposure to ammonia in the urea plant was associated with an increased prevalence of respiratory symptoms and an acute decline in lung function.
[Instruments for quantitative methods of nursing research].
Vellone, E
2000-01-01
Instruments for quantitative nursing research are a mean to objectify and measure a variable or a phenomenon in the scientific research. There are direct instruments to measure concrete variables and indirect instruments to measure abstract concepts (Burns, Grove, 1997). Indirect instruments measure the attributes by which a concept is made of. Furthermore, there are instruments for physiologic variables (e.g. for the weight), observational instruments (Check-lists e Rating Scales), interviews, questionnaires, diaries and the scales (Check-lists, Rating Scales, Likert Scales, Semantic Differential Scales e Visual Anologue Scales). The choice to select an instrument or another one depends on the research question and design. Instruments research are very useful in research both to describe the variables and to see statistical significant relationships. Very carefully should be their use in the clinical practice for diagnostic assessment.
Giacomelli, Giovanni; Virgili, Gianni; Giansanti, Fabrizio; Sato, Giovanni; Cappello, Ezio; Cruciani, Filippo; Varano, Monica; Menchini, Ugo
2013-06-27
To investigate the simultaneous association of several psychophysical measures with reading ability in patients with mild and moderate low vision attending rehabilitation services. Standard measurements of reading ability (Minnesota Reading [MNREAD] charts), visual acuity (Early Treatment of Diabetic Retinopathy Study [ETDRS] charts), contrast sensitivity (Pelli-Robson charts), reading contrast threshold (Reading Explorer [REX] charts), retinal sensitivity, and fixation stability and localization (Micro Perimeter 1 [MP1] fundus perimetry) were obtained in 160 low vision patients with better eye visual acuity ranging from 0.3 to 1.0 logarithm of the minimum angle of resolution and affected by either age-related macular degeneration or diabetic retinopathy. All variables were moderately associated with reading performance measures (MNREAD reading speed and reading acuity and REX reading contrast threshold), as well as among each other. In a structural equation model, REX reading contrast threshold was highly associated with MNREAD reading speed (standardized coefficient, 0.63) and moderately associated with reading acuity (standardized coefficient, -0.30). REX test also mediated the effects of Pelli-Robson contrast sensitivity (standardized coefficient, 0.44), MP1 fixation eccentricity (standardized coefficient, -0.19), and the mean retinal sensitivity (standardized coefficient, 0.23) on reading performance. The MP1 fixation stability was associated with both MNREAD reading acuity (standardized coefficient, -0.24) and MNREAD reading speed (standardized coefficient, 0.23), while ETDRS visual acuity only affected reading acuity (standardized coefficient, 0.44). Fixation instability and contrast sensitivity loss are key factors limiting reading performance of patients with mild or moderate low vision. REX charts directly assess the impact of text contrast on letter recognition and text navigation and may be a useful aid in reading rehabilitation.
Coordinated weather balloon solar radiation measurements during a solar eclipse
2016-01-01
Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes. This article is part of the themed issue ‘Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse’. PMID:27550757
Coordinated weather balloon solar radiation measurements during a solar eclipse.
Harrison, R G; Marlton, G J; Williams, P D; Nicoll, K A
2016-09-28
Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'. © 2016 The Authors.
Force-detected nanoscale absorption spectroscopy in water at room temperature using an optical trap
NASA Astrophysics Data System (ADS)
Parobek, Alexander; Black, Jacob W.; Kamenetska, Maria; Ganim, Ziad
2018-04-01
Measuring absorption spectra of single molecules presents a fundamental challenge for standard transmission-based instruments because of the inherently low signal relative to the large background of the excitation source. Here we demonstrate a new approach for performing absorption spectroscopy in solution using a force measurement to read out optical excitation at the nanoscale. The photoinduced force between model chromophores and an optically trapped gold nanoshell has been measured in water at room temperature. This photoinduced force is characterized as a function of wavelength to yield the force spectrum, which is shown to be correlated to the absorption spectrum for four model systems. The instrument constructed for these measurements combines an optical tweezer with frequency domain absorption spectroscopy over the 400-800 nm range. These measurements provide proof-of-principle experiments for force-detected nanoscale spectroscopies that operate under ambient chemical conditions.
How is the instrumental color of meat measured?
Tapp, W N; Yancey, J W S; Apple, J K
2011-09-01
Peer-reviewed journal articles (n=1068) were used to gather instrumental color measurement information in meat science research. The majority of articles, published in 10 peer-reviewed journals, originated from European countries (44.8%) and North America (38.5%). The predominant species was pork (44.2%), and most researchers used Minolta (60.0%) over Hunter (31.6%) colorimeters. Much of the research was done using illuminant D65 (32.3%); nevertheless, almost half (48.9%) of the articles did not report the illuminant. Moreover, a majority of the articles did not report aperture size (73.6%) or the number of readings per sample (52.4%). Many factors influence meat color, and a considerable proportion of the peer-reviewed, published research articles failed to include information necessary to replicate and/or interpret instrumental color results; therefore, a standardized set of minimum reportable parameters for meat color evaluation should be identified. Copyright © 2011 Elsevier Ltd. All rights reserved.
Rockall, Andrea G; Avril, Norbert; Lam, Raymond; Iannone, Robert; Mozley, P David; Parkinson, Christine; Bergstrom, Donald; Sala, Evis; Sarker, Shah-Jalal; McNeish, Iain A; Brenton, James D
2014-05-15
Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer. Patients underwent two pretreatment baseline FDG-PET/CT (n = 21) and CECT (n = 20) at two clinical sites with different PET/CT instruments. Patients were included if they had at least one target lesion in the abdomen with a standardized uptake value (SUV) maximum (SUVmax) of ≥ 2.5 and a long axis diameter of ≥ 15 mm. Two independent reading methods were used to evaluate repeatability of tumor diameter and SUV uptake: on site and at an imaging clinical research organization (CRO). Tumor volume reads were only performed by CRO. In each reading set, target lesions were independently measured on sequential imaging. Median time between FDG-PET/CT was two days (range 1-7). For site reads, concordance correlation coefficients (CCC) for SUVmean, SUVmax, and tumor diameter were 0.95, 0.94, and 0.99, respectively. Repeatability coefficients were 16.3%, 17.3%, and 8.8% for SUVmean, SUVmax, and tumor diameter, respectively. Similar results were observed for CRO reads. Tumor volume CCC was 0.99 with a repeatability coefficient of 28.1%. There was excellent test-retest repeatability for FDG-PET/CT quantitative measurements across two sites and two independent reading methods. Cutoff values for determining change in SUVmean, SUVmax, and tumor volume establish limits to determine metabolic and/or volumetric response to treatment in platinum-sensitive relapsed ovarian cancer. ©2014 American Association for Cancer Research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peabody, C.O.
1963-12-01
Measurements were made of the response of five commonly used health physics instruments when held near polythene man-phantoms filled with aqueous solutions containing sodium-24 and chlorine-38. The ratios of the wholebody chlorine-38 and sodium-24 activities are calculated for various periods of accidental human irradiation by neutrons. These ratios and the phantom results are used to estimate the response of the five instruments when held near the human body at various times after irradiation. Relative contributions of the chlorine-38 and sodium-24 to the instrument indications are listed. The tabulated data enable the instrument readings to be converted to wholebody sodium- 24more » activity at the time of irradiation. This may be used as a quick estimate of the degree of neutron irradiation. (auth)« less
Staneck, J L; Allen, S D; Harris, E E; Tilton, R C
1985-01-01
The Sensititre Autoreader is a microcomputer-driven instrument capable of automatically reading antimicrobial susceptibility microdilution trays. The instrument measures the fluorescence liberated by bacterial enzymatic activity on fluorogenic substrates as an indicator of growth in each well. A mathematical algorithm converts the fluorescent signals from an antimicrobial dilution series to an MIC endpoint. A three-center study evaluated the performance of the Autoreader in comparison with MIC determined visually in a duplicate set of control plates lacking fluorogenic substrate. Among 828 isolates of gram-negative bacilli tested against 17 antimicrobial agents, Autoreader 18-h MIC were within +/- 1 twofold dilution of control MIC values (agreement) in 95.3% of instances. In 3.5% of the instances, Autoreader values occurred +/- 2 half-step dilutions from control values (minor discrepancy), and in only 1.2% of instances did Autoreader values deviate from control values by greater than +/- 2 dilution steps (major discrepancy). Agreement, minor discrepancies, and major discrepancies were noted among 148 gram-positive cocci tested against 11 antimicrobial agents in 93.5, 4.8, and 1.7% of the instances, respectively. Over half of the major discrepancies noted with gram-negative bacilli occurred with Proteus mirabilis-beta-lactam combinations, a problem that was resolved when a lower initial inoculum was used. Inter-and intralaboratory reproducibility was excellent. Standard Sensititre susceptibility trays may be instrument read at 18 h reproducibly and accurately with only slight modification of conventional procedures to include fluorogenic enzyme substrates in the incubation broth. PMID:4031033
Total atmospheric ozone determined from spectral measurements of direct solar UV irradiance
NASA Astrophysics Data System (ADS)
Huber, Martin; Blumthaler, Mario; Ambach, Walter; Staehelin, Johannes
1995-01-01
With a double monochromator, high resolution spectral measurements of direct solar UV-irradiance were performed in Arosa during February and March, 1993. Total atmospheric ozone amount is determined by fitting model calculations to the measured spectra. The results are compared with the operationally performed measurements of a Dobson and a Brewer spectrometer. The total ozone amount determined from spectral measurements differs from the results of the Dobson instrument by -1.1±0.9% and from those of the Brewer instrument by -0.4±0.7%.
Measurement of proton momentum distributions using a direct geometry instrument
NASA Astrophysics Data System (ADS)
Senesi, R.; Kolesnikov, A. I.; Andreani, C.
2014-12-01
We report the results of inelastic neutron scattering measurements on bulk water and ice using the direct geometry SEQUOIA chopper spectrometer at the Spallation Neutron Source (USA), with incident energy Ei= 6 eV. In this set up the measurements allow to access the Deep Inelastic Neutron Scattering regime. The scattering is centred at the proton recoil energy given by the impulse approximation, and the shape of the recoil peak conveys information on the proton momentum distribution in the system. The comparison with the performance of inverse geometry instruments, such as VESUVIO at the ISIS source (UK), shows that complementary information can be accessed by the use of direct and inverse geometry instruments. Analysis of the neutron Compton profiles shows that the proton kinetic energy in ice at 271 K is larger than in room temperature liquid water, in agreement with previous measurements on VESUVIO.
Advanced system on a chip microelectronics for spacecraft and science instruments
NASA Astrophysics Data System (ADS)
Paschalidis, Nikolaos P.
2003-01-01
The explosive growth of the modern microelectronics field opens new horizons for the development of new lightweight, low power, and smart spacecraft and science instrumentation systems in the new millennium explorations. Although this growth is mostly driven by the commercial need for low power, portable and computationally intensive products, the applicability is obvious in the space sector. The additional difficulties needed to be overcome for applicability in space include radiation hardness for total ionizing dose and single event effects (SEE), and reliability. Additionally, this new capability introduces a whole new philosophy of design and R&D, with strong implications in organizational and inter-agency program management. One key component specifically developed towards low power, small size, highly autonomous spacecraft systems, is the smart sensor remote input/output (TRIO) chip. TRIO can interface to 32 transducers with current sources/sinks and voltage sensing. It includes front-end analog signal processing, a 10-bit ADC, memory, and standard serial and parallel I/Os. These functions are very useful for spacecraft and subsystems health and status monitoring, and control actions. The key contributions of the TRIO are feasibility of modular architectures, elimination of several miles of wire harnessing, and power savings by orders of magnitude. TRIO freely operates from a single power supply 2.5- 5.5 V with power dissipation <10 mW. This system on a chip device rapidly becomes a NASA and Commercial Space standard as it is already selected by thousands in several new millennium missions, including Europa Orbiter, Mars Surveyor Program, Solar Probe, Pluto Express, Stereo, Contour, Messenger, etc. In the Science Instrumentation field common instruments that can greatly take advantage of the new technologies are: energetic-particle/plasma and wave instruments, imagers, mass spectrometers, X-ray and UV spectrographs, magnetometers, laser rangefinding instruments, etc. Common measurements that apply to many of these instruments are precise time interval measurement and high resolution read-out of solid state detectors. A precise time interval measurement chip was specially developed that achieves ˜100 ps (×10 improvement) time resolution at a power dissipation ˜20 mW (×50 improvement), dead time ˜1.5 μs (×20 improvement), and chip die size 5 mm×5 mm versus two 20 cm×20 cm doubled sided boards. This device is selected as a key enabling technology for several NASA particle, delay line imaging, and laser range finding instruments onboard (NASA Image, Messenger, etc. missions). Another device with universal application is radiation energy read-out from solid state detectors. Multi-channel low-power and end-to-end sensor input—digital output is key for the new generation instruments. The readout channel comprises of a Charge Sensitive Preamplifier with a target sensitivity of ˜1 KeV FWHM at 20 pf detector capacitance, a Shaper Amplifier with programmable time constant/gain, and an ADC. The read-out chip together with the precise time interval chip comprises the essential elements of a common particle spectroscopy instrument. To mention some more applications fast-signal acquisition—and digitization is a very useful function for a category of instrument such as mass spectroscopy and profile laser rangefinding. The single chip approach includes a high bandwidth preamplifier, fast sampling ˜5 ns, analog memory ˜10K locations, 12-bit ADC and serial/parallel I/Os. The wealth of the applications proves the advanced microelectronics field as a key enabling technology for the new millennium space exploration.
NASA Astrophysics Data System (ADS)
Lazzi Gazzini, S.; Schädler, R.; Kalfas, A. I.; Abhari, R. S.
2017-02-01
It is technically challenging to measure heat fluxes on the rotating components of gas turbines, yet accurate knowledge of local heat loads under engine-representative conditions is crucial for ensuring the reliability of the designs. In this work, quantitative image processing tools were developed to perform fast and accurate infrared thermography measurements on 3D-shaped film-heaters directly deposited on the turbine endwalls. The newly developed image processing method and instrumentation were used to measure the heat load on the rotor endwalls of an axial turbine. A step-transient heat flux calibration technique is applied to measure the heat flux generated locally by the film heater, thus eliminating the need for a rigorously iso-energetic boundary condition. On-board electronics installed on the rotor record the temperature readings of RTDs installed in the substrate below the heaters in order to evaluate the conductive losses in the solid. Full maps of heat transfer coefficient and adiabatic wall temperature are produced for two different operating conditions, demonstrating the sensitivity of the technique to local flow features and variations in heat transfer due to Reynolds number effect.
ERIC Educational Resources Information Center
Alzu'bi, Mohammad Akram
2014-01-01
This study aimed at investigating the impact of extensive reading on improving reading proficiency. The study tried to find the effect of ER on EFL student's reading, vocabulary and grammar. The researcher designed two instruments; a program based on the extensive reading strategy and general test. Forty-one university students who study English…
Lodge, Amy C; Kuhn, Wendy; Earley, Juli; Stevens Manser, Stacey
2018-06-01
The Recovery Self-Assessment (RSA) is a reliable and valid tool used to measure recovery-oriented services. Recent studies, however, suggest that the length and reading level of the RSA makes its routine use in service settings difficult. Recognizing the importance of including people with lived experience of a mental health challenge in research processes and the need to enhance the utility of tools that measure recovery-oriented services, this paper describes an innovative researcher-peer provider consultant multistep process used to revise the provider version of the RSA to create a new instrument-the Recovery-Oriented Services Assessment (ROSA). The authors conducted an exploratory factor analysis (EFA) with principal axis factoring extraction and direct oblimin rotation to evaluate the underlying structure of the provider RSA using data from mental health employees (n = 323). To triangulate the findings of the EFA, quantitative and qualitative data were collected from peer provider consultants (n = 9) on the importance of and language of RSA items. EFA results indicated that a 1-factor solution provided the best fit and explained 48% of the total variance. Consultants triangulated EFA results and recommended the addition of 2 items and language revisions. These results were used to develop the ROSA-a 15-item instrument measuring recovery-oriented services with accessible language. Two versions of the ROSA were developed: a staff version and a people-in-services version. The ROSA may provide organizations with a more accessible way to measure the extent to which their services are recovery oriented. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Direct-reading group-delay measurement
NASA Technical Reports Server (NTRS)
Trowbridge, D. L.
1978-01-01
Technique for measuring modulation signal retardation in microwave components gives direct plot of dependence of delay time on carrier frequency. Recorder sensitivity can be adjusted to give convenient scale factor for group delay. From family of such recordings, it is possible to observe changes in group delay due to temperature, mechanical stress, and other factors.
Seismic reading taken at MSC recording impact of Apollo 13 S-IVB with surface
NASA Technical Reports Server (NTRS)
1970-01-01
A seismic reading taken from instruments at the Manned Spacecraft Center (MSC) recording impact of the Apollo 13 S-IVB/Instrument Unit with lunar surface. The expended Saturn third stage and instrument unit impacted the lunar surface at 7:09 p.m., April 14, 1970. The location of the impact was 2.4 degrees south latitude and 27.9 degrees west longitude, about 76 nautical miles west-northwest of the Apollo 12 Lunar Surface Experiment package deployment site. The S-IVB/IU impact was picked up by the Passive Seismic Experiment, a component of the package and transmitted to instruments at the Mission Control Center.
Normalization of energy-dependent gamma survey data.
Whicker, Randy; Chambers, Douglas
2015-05-01
Instruments and methods for normalization of energy-dependent gamma radiation survey data to a less energy-dependent basis of measurement are evaluated based on relevant field data collected at 15 different sites across the western United States along with a site in Mongolia. Normalization performance is assessed relative to measurements with a high-pressure ionization chamber (HPIC) due to its "flat" energy response and accurate measurement of the true exposure rate from both cosmic and terrestrial radiation. While analytically ideal for normalization applications, cost and practicality disadvantages have increased demand for alternatives to the HPIC. Regression analysis on paired measurements between energy-dependent sodium iodide (NaI) scintillation detectors (5-cm by 5-cm crystal dimensions) and the HPIC revealed highly consistent relationships among sites not previously impacted by radiological contamination (natural sites). A resulting generalized data normalization factor based on the average sensitivity of NaI detectors to naturally occurring terrestrial radiation (0.56 nGy hHPIC per nGy hNaI), combined with the calculated site-specific estimate of cosmic radiation, produced reasonably accurate predictions of HPIC readings at natural sites. Normalization against two to potential alternative instruments (a tissue-equivalent plastic scintillator and energy-compensated NaI detector) did not perform better than the sensitivity adjustment approach at natural sites. Each approach produced unreliable estimates of HPIC readings at radiologically impacted sites, though normalization against the plastic scintillator or energy-compensated NaI detector can address incompatibilities between different energy-dependent instruments with respect to estimation of soil radionuclide levels. The appropriate data normalization method depends on the nature of the site, expected duration of the project, survey objectives, and considerations of cost and practicality.
Amador Fierros, Genoveva; Montesinos-López, Osval Antonio; Alcaráz Moreno, Noemí
2016-04-01
This work sought to validate and propose an instrument to measure the performance of tutors in promoting self-directed learning in students involved in processes of problem-based learning. Confirmatory factor analysis (CFA) was applied to validate the instrument composed of 60 items and six factors (self-assessment of learning gaps within the United Nations specific context: self-assessment, reflexion, critical thinking, administration of information, group skills), using a sample of 207 students from a total of 279, which comprise the student population of the Faculty of Nursing at Universidad de Colima in Mexico. (2007). The CFA results demonstrated that the instrument is acceptable to measure performance of tutors in promoting self-directed learning, given that all the indicators, variances, covariances, and thresholds are statistically significant. The instrument permits obtaining students' opinions on how much professors contribute for them to develop each of the 60 skills described in the scale. Lastly, the results could report if professors are placing more emphasis in some areas than in other areas they should address during the problem-based learning (PBL) process, or if definitely their actions are removed from the premises of PBL, information that will be useful for school management in decision making on the direction of teaching as a whole.
ERIC Educational Resources Information Center
van Bergen, Elsje; van Zuijen, Titia; Bishop, Dorothy; de Jong, Peter F.
2017-01-01
Associations between home literacy environment and children's reading ability are often assumed to reflect a direct influence. However, heritability could account for the association between parent and child literacy-related measures. We used data from 101 mother/father/child triads to consider the extent to which associations between home…
Comparing Two Methods of Writing Instruction: Effects on Kindergarten Students' Reading Skills
ERIC Educational Resources Information Center
Jones, Cindy D'on; Reutzel, D. Ray; Fargo, Jamison D.
2010-01-01
This experimental study directly compared the effects of two prevalent forms of classroom writing instruction, interactive writing and writing workshop, on kindergarten students' acquisition of early reading skills. Repeated measures data was collected at four points over 16 weeks to monitor growth of 151 kindergarten students in phonological…
Can Readability Formulas Be Used to Successfully Gauge Difficulty of Reading Materials?
ERIC Educational Resources Information Center
Begeny, John C.; Greene, Diana J.
2014-01-01
A grade level of reading material is commonly estimated using one or more readability formulas, which purport to measure text difficulty based on specified text characteristics. However, there is limited direction for teachers and publishers regarding which readability formulas (if any) are appropriate indicators of actual text difficulty. Because…
ERIC Educational Resources Information Center
DeThorne, Laura Segebart; Hart, Sara A.; Petrill, Stephen A.; Deater-Deckard, Kirby; Thompson, Lee Anne; Schatschneider, Chris; Davison, Megan Dunn
2006-01-01
Purpose: This study examined (a) the extent of genetic and environmental influences on children's articulation and language difficulties and (b) the phenotypic associations between such difficulties and direct assessments of reading-related skills during early school-age years. Method: Behavioral genetic analyses focused on parent-report data…
Low-income fathers’ speech to toddlers during book reading versus toy play*
Salo, Virginia C.; Rowe, Meredith L.; Leech, Kathryn A.; Cabrera, Natasha J.
2016-01-01
Fathers’ child-directed speech across two contexts was examined. Father–child dyads from sixty-nine low-income families were videotaped interacting during book reading and toy play when children were 2;0. Fathers used more diverse vocabulary and asked more questions during book reading while their mean length of utterance was longer during toy play. Variation in these specific characteristics of fathers’ speech that differed across contexts was also positively associated with child vocabulary skill measured on the MacArthur-Bates Communicative Development Inventory. Results are discussed in terms of how different contexts elicit specific qualities of child-directed speech that may promote language use and development. PMID:26541647
Clinical tonometric measurements comparing three non-contact tonometers.
Walby, M A; Augsburger, A; Polasky, M
1975-06-01
Three American Optical Non-contact Tonometers were used to compare readings against each other. The attempt was to determine if all three tonometers were measuring the same IOP over a wide range of pressures. The assumption in practice is that all Non-contact Tonometers are manufactured within tolerance that should allow the examiner to find that same IOP on a patient regardless of the Non-contact Tonometer used. A preliminary study found no significant difference between the instruments.
ERIC Educational Resources Information Center
Iwai, Yuko; Filce, Hollie; Ramp, Ellen
2011-01-01
In this study, the authors examined the impact of metacognitive reading strategies on international college students' academic success by correcting the Survey of Reading Strategies (SORS) instrument with (a) grade point averages (GPAs) and (b) the English language proficiency levels, categorized by beginning (students at the English Language…
Balance Calibration – A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mike Stears
2010-07-01
Paper Title: Balance Calibration – A method for assigning a direct-reading uncertainty to an electronic balance. Intended Audience: Those who calibrate or use electronic balances. Abstract: As a calibration facility, we provide on-site (at the customer’s location) calibrations of electronic balances for customers within our company. In our experience, most of our customers are not using their balance as a comparator, but simply putting an unknown quantity on the balance and reading the displayed mass value. Manufacturer’s specifications for balances typically include specifications such as readability, repeatability, linearity, and sensitivity temperature drift, but what does this all mean when themore » balance user simply reads the displayed mass value and accepts the reading as the true value? This paper discusses a method for assigning a direct-reading uncertainty to a balance based upon the observed calibration data and the environment where the balance is being used. The method requires input from the customer regarding the environment where the balance is used and encourages discussion with the customer regarding sources of uncertainty and possible means for improvement; the calibration process becomes an educational opportunity for the balance user as well as calibration personnel. This paper will cover the uncertainty analysis applied to the calibration weights used for the field calibration of balances; the uncertainty is calculated over the range of environmental conditions typically encountered in the field and the resulting range of air density. The temperature stability in the area of the balance is discussed with the customer and the temperature range over which the balance calibration is valid is decided upon; the decision is based upon the uncertainty needs of the customer and the desired rigor in monitoring by the customer. Once the environmental limitations are decided, the calibration is performed and the measurement data is entered into a custom spreadsheet. The spreadsheet uses measurement results, along with the manufacturer’s specifications, to assign a direct-read measurement uncertainty to the balance. The fact that the assigned uncertainty is a best-case uncertainty is discussed with the customer; the assigned uncertainty contains no allowance for contributions associated with the unknown weighing sample, such as density, static charges, magnetism, etc. The attendee will learn uncertainty considerations associated with balance calibrations along with one method for assigning an uncertainty to a balance used for non-comparison measurements.« less
WFC3: IR Detector On-Orbit Performance
NASA Astrophysics Data System (ADS)
Hilbert, Bryan; Dulude, M.; McCullough, P.; MacKenty, J. W.; Kimble, R. A.; Hill, R. J.; Viana, A.; Bushouse, H.; Baggett, S.; WFC3 Team
2010-01-01
Using data taken during Servicing Mission Observatory Verification (SMOV4), we have characterized dark current and readnoise behavior of the IR Channel, along with its level of measured background signal. Using data taken in June and July of 2009, we find the dark current in the IR channel to be 0.043 - 0.050 e-/s/pixel. The correlated double sampling (CDS) read noise in RAPID sequences is 20-22 electrons, similar to that measured in ground testing. The effective noise measured in an image created from 16 reads of a SPARS200 ramp is 11.6 - 12.7 electrons. Using internal flat field images, we measured the inverse gain to be 2.28 - 2.47 ± 0.04 e-/ADU, depending on quadrant. The ratio of the mean instrumental irradiance (ADU/s/pixel) measured on orbit to that obtained in ground testing is 1.06 - 1.07, indicating a brightening of the Tungsten lamp on orbit. We also note the continued appearance of cosmic ray-like sources, dubbed "snowballs", in on orbit data.
Chesters, Jennifer; Möttönen, Riikka; Watkins, Kate E
2018-04-01
See Crinion (doi:10.1093/brain/awy075) for a scientific commentary on this article.Stuttering is a neurodevelopmental condition affecting 5% of children, and persisting in 1% of adults. Promoting lasting fluency improvement in adults who stutter is a particular challenge. Novel interventions to improve outcomes are of value, therefore. Previous work in patients with acquired motor and language disorders reported enhanced benefits of behavioural therapies when paired with transcranial direct current stimulation. Here, we report the results of the first trial investigating whether transcranial direct current stimulation can improve speech fluency in adults who stutter. We predicted that applying anodal stimulation to the left inferior frontal cortex during speech production with temporary fluency inducers would result in longer-lasting fluency improvements. Thirty male adults who stutter completed a randomized, double-blind, controlled trial of anodal transcranial direct current stimulation over left inferior frontal cortex. Fifteen participants received 20 min of 1-mA stimulation on five consecutive days while speech fluency was temporarily induced using choral and metronome-timed speech. The other 15 participants received the same speech fluency intervention with sham stimulation. Speech fluency during reading and conversation was assessed at baseline, before and after the stimulation on each day of the 5-day intervention, and at 1 and 6 weeks after the end of the intervention. Anodal stimulation combined with speech fluency training significantly reduced the percentage of disfluent speech measured 1 week after the intervention compared with fluency intervention alone. At 6 weeks after the intervention, this improvement was maintained during reading but not during conversation. Outcome scores at both post-intervention time points on a clinical assessment tool (the Stuttering Severity Instrument, version 4) also showed significant improvement in the group receiving transcranial direct current stimulation compared with the sham group, in whom fluency was unchanged from baseline. We conclude that transcranial direct current stimulation combined with behavioural fluency intervention can improve fluency in adults who stutter. Transcranial direct current stimulation thereby offers a potentially useful adjunct to future speech therapy interventions for this population, for whom fluency therapy outcomes are currently limited.
An intercomparison of airborne nitrogen dioxide instruments
NASA Technical Reports Server (NTRS)
Gregory, G. L.; Hoell, J. M., Jr.; Carroll, M. A.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Sandholm, S. T.; Schiff, H. I.; Torres, A. L.
1990-01-01
Results on NO2 instruments are reported from the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986. The instruments tested were (1) a two-photon LIF system using a laser for NO2-NO photolysis, (2) a chemiluminescence (CL) detector using FeSO4 for NO2-NO conversion, (3) a CL detector using an arc lamp for NO2-NO photolysis, and (4) a tunable-laser-diode multipath-absorption system. The procedures for the CITE 2 ground-based and flight tests are described in detail, and the results are presented in extensive graphs. Instrument (2) was eliminated because the FeSO4 converted atmospheric PAN to NO, resulting in spuriously high NO2 values. The remaining instruments gave readings in 30-40-percent agreement at NO2 mixing ratios of 100-200 parts per trillion by volume (pptv). At ratios below 50 pptv, the correlation among the measurements was very poor, with a tendency for system (4) to give higher values than (1) or (3).
NASA Astrophysics Data System (ADS)
Amato, A.; Luetkens, H.; Sedlak, K.; Stoykov, A.; Scheuermann, R.; Elender, M.; Raselli, A.; Graf, D.
2017-09-01
We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (SμS) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon (GPS) instrument that has been for long the workhorse of the μSR user facility at PSI. By making use of muon and positron detectors made of plastic scintillators read out by silicon photomultipliers, a time resolution of the complete instrument of about 160 ps (standard deviation) could be achieved. In addition, the absence of light guides, which are needed in traditionally built μSR instrument to deliver the scintillation light to photomultiplier tubes located outside magnetic fields applied, allowed us to design a compact instrument with a detector set covering an increased solid angle compared with the old GPS.
45 CFR 2520.25 - What direct service activities may AmeriCorps members perform?
Code of Federal Regulations, 2014 CFR
2014-10-01
... activities that provide a direct, measurable benefit to an individual, a group, or a community. (d) Examples... to, the following: (1) Tutoring children in reading; (2) Helping to run an after-school program; (3...
45 CFR 2520.25 - What direct service activities may AmeriCorps members perform?
Code of Federal Regulations, 2013 CFR
2013-10-01
... activities that provide a direct, measurable benefit to an individual, a group, or a community. (d) Examples... to, the following: (1) Tutoring children in reading; (2) Helping to run an after-school program; (3...
45 CFR 2520.25 - What direct service activities may AmeriCorps members perform?
Code of Federal Regulations, 2011 CFR
2011-10-01
... activities that provide a direct, measurable benefit to an individual, a group, or a community. (d) Examples... to, the following: (1) Tutoring children in reading; (2) Helping to run an after-school program; (3...
45 CFR 2520.25 - What direct service activities may AmeriCorps members perform?
Code of Federal Regulations, 2012 CFR
2012-10-01
... activities that provide a direct, measurable benefit to an individual, a group, or a community. (d) Examples... to, the following: (1) Tutoring children in reading; (2) Helping to run an after-school program; (3...
NASA Astrophysics Data System (ADS)
Peterson, David; Coumou, David; Shannon, Steven
2015-11-01
Time resolved electron density measurements in pulsed RF discharges are shown using a hairpin resonance probe using low cost electronics, on par with normal Langmuir probe boxcar mode operation. Time resolution of 10 microseconds has been demonstrated. A signal generator produces the applied microwave frequency; the reflected waveform is passed through a directional coupler and filtered to remove the RF component. The signal is heterodyned with a frequency mixer and rectified to produce a DC signal read by an oscilloscope. At certain points during the pulse, the plasma density is such that the applied frequency is the same as the resonance frequency of the probe/plasma system, creating reflected signal dips. The applied microwave frequency is shifted in small increments in a frequency boxcar routine to determine the density as a function of time. A dc sheath correction is applied for the grounded probe, producing low cost, high fidelity, and highly reproducible electron density measurements. The measurements are made in both inductively and capacitively coupled systems, the latter driven by multiple frequencies where a subset of these frequencies are pulsed. Measurements are compared to previous published results, time resolved OES, and in-line measurement of plasma impedance. This work is supported by the NSF DOE partnership on plasma science, the NSF GOALI program, and MKS Instruments.
The FIELDS Instrument Suite for Solar Probe Plus
NASA Technical Reports Server (NTRS)
Bale, S. D.; Goetz, K.; Harvey, P. R.; Turin, P.; Bonnell, J. W.; Dudok de Wit, T.; Ergun, R. E.; MacDowall, R. J.; Pulupa, M.; Andre, M.;
2016-01-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
The FIELDS Instrument Suite for Solar Probe Plus
Goetz, K.; Harvey, P.R.; Turin, P.; Bonnell, J.W.; de Wit, T. Dudok; Ergun, R.E.; MacDowall, R.J.; Pulupa, M.; Andre, M.; Bolton, M.; Bougeret, J.-L.; Bowen, T.A.; Burgess, D.; Cattell, C.A.; Chandran, B.D.G.; Chaston, C.C.; Chen, C.H.K.; Choi, M.K.; Connerney, J.E.; Cranmer, S.; Diaz-Aguado, M.; Donakowski, W.; Drake, J.F.; Farrell, W.M.; Fergeau, P.; Fermin, J.; Fischer, J.; Fox, N.; Glaser, D.; Goldstein, M.; Gordon, D.; Hanson, E.; Harris, S.E.; Hayes, L.M.; Hinze, J.J.; Hollweg, J.V.; Horbury, T.S.; Howard, R. A.; Hoxie, V.; Jannet, G.; Karlsson, M.; Kasper, J.C.; Kellogg, P.J.; Kien, M.; Klimchuk, J.A.; Krasnoselskikh, V.V.; Krucker, S.; Lynch, J.J.; Maksimovic, M.; Malaspina, D.M.; Marker, S.; Martin, P.; Martinez-Oliveros, J.; McCauley, J.; McComas, D.J.; McDonald, T.; Meyer-Vernet, N.; Moncuquet, M.; Monson, S.J.; Mozer, F.S.; Murphy, S.D.; Odom, J.; Oliverson, R.; Olson, J.; Parker, E.N.; Pankow, D.; Phan, T.; Quataert, E.; Quinn, T.; Ruplin, S.W.; Salem, C.; Seitz, D.; Sheppard, D.A.; Siy, A.; Stevens, K.; Summers, D.; Szabo, A.; Timofeeva, M.; Vaivads, A.; Velli, M.; Yehle, A.; Werthimer, D.; Wygant, J.R.
2018-01-01
NASA’s Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products. PMID:29755144
ERIC Educational Resources Information Center
Lordán, Eva; Solé, Isabel; Beltran, Francesc S.
2017-01-01
The aim of this research was to develop a new questionnaire for exploring the reading beliefs of undergraduate students, because the only currently available instrument has conceptual and methodological limitations. The paper describes the process of developing the instrument and presents a range of psychometric data obtained from a sample of 558…
ERIC Educational Resources Information Center
Fuchs, Douglas; Compton, Donald L.; Fuchs, Lynn S.; Bouton, Bobette; Caffrey, Erin
2011-01-01
The purpose of this study was to examine the construct and predictive validity of a dynamic assessment (DA) of decoding learning. Students (N = 318) were assessed in the fall of first grade on an array of instruments that were given in hopes of forecasting responsiveness to reading instruction. These instruments included DA as well as…
NASA Technical Reports Server (NTRS)
Bale, S. D.; Goetz, K.; Harvey, P. R.; Turin, P.; Bonnell, J. W.; Dudok de Wit, T.; Ergun, R. E.; MacDowall, R. J.; Pulupa, M.; Choi, M. K.;
2016-01-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
Bale, S D; Goetz, K; Harvey, P R; Turin, P; Bonnell, J W; de Wit, T Dudok; Ergun, R E; MacDowall, R J; Pulupa, M; Andre, M; Bolton, M; Bougeret, J-L; Bowen, T A; Burgess, D; Cattell, C A; Chandran, B D G; Chaston, C C; Chen, C H K; Choi, M K; Connerney, J E; Cranmer, S; Diaz-Aguado, M; Donakowski, W; Drake, J F; Farrell, W M; Fergeau, P; Fermin, J; Fischer, J; Fox, N; Glaser, D; Goldstein, M; Gordon, D; Hanson, E; Harris, S E; Hayes, L M; Hinze, J J; Hollweg, J V; Horbury, T S; Howard, R A; Hoxie, V; Jannet, G; Karlsson, M; Kasper, J C; Kellogg, P J; Kien, M; Klimchuk, J A; Krasnoselskikh, V V; Krucker, S; Lynch, J J; Maksimovic, M; Malaspina, D M; Marker, S; Martin, P; Martinez-Oliveros, J; McCauley, J; McComas, D J; McDonald, T; Meyer-Vernet, N; Moncuquet, M; Monson, S J; Mozer, F S; Murphy, S D; Odom, J; Oliverson, R; Olson, J; Parker, E N; Pankow, D; Phan, T; Quataert, E; Quinn, T; Ruplin, S W; Salem, C; Seitz, D; Sheppard, D A; Siy, A; Stevens, K; Summers, D; Szabo, A; Timofeeva, M; Vaivads, A; Velli, M; Yehle, A; Werthimer, D; Wygant, J R
2016-12-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
NASA Astrophysics Data System (ADS)
Bale, S. D.; Goetz, K.; Harvey, P. R.; Turin, P.; Bonnell, J. W.; Dudok de Wit, T.; Ergun, R. E.; MacDowall, R. J.; Pulupa, M.; Andre, M.; Bolton, M.; Bougeret, J.-L.; Bowen, T. A.; Burgess, D.; Cattell, C. A.; Chandran, B. D. G.; Chaston, C. C.; Chen, C. H. K.; Choi, M. K.; Connerney, J. E.; Cranmer, S.; Diaz-Aguado, M.; Donakowski, W.; Drake, J. F.; Farrell, W. M.; Fergeau, P.; Fermin, J.; Fischer, J.; Fox, N.; Glaser, D.; Goldstein, M.; Gordon, D.; Hanson, E.; Harris, S. E.; Hayes, L. M.; Hinze, J. J.; Hollweg, J. V.; Horbury, T. S.; Howard, R. A.; Hoxie, V.; Jannet, G.; Karlsson, M.; Kasper, J. C.; Kellogg, P. J.; Kien, M.; Klimchuk, J. A.; Krasnoselskikh, V. V.; Krucker, S.; Lynch, J. J.; Maksimovic, M.; Malaspina, D. M.; Marker, S.; Martin, P.; Martinez-Oliveros, J.; McCauley, J.; McComas, D. J.; McDonald, T.; Meyer-Vernet, N.; Moncuquet, M.; Monson, S. J.; Mozer, F. S.; Murphy, S. D.; Odom, J.; Oliverson, R.; Olson, J.; Parker, E. N.; Pankow, D.; Phan, T.; Quataert, E.; Quinn, T.; Ruplin, S. W.; Salem, C.; Seitz, D.; Sheppard, D. A.; Siy, A.; Stevens, K.; Summers, D.; Szabo, A.; Timofeeva, M.; Vaivads, A.; Velli, M.; Yehle, A.; Werthimer, D.; Wygant, J. R.
2016-12-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A
2012-05-05
Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.
Instrument performance of a radon measuring system with the alpha-track detection technique.
Tokonami, S; Zhuo, W; Ryuo, H; Yonehara, H; Yamada, Y; Shimo, M
2003-01-01
An instrument performance test has been carried out for a radon measuring system made in Hungary. The system measures radon using the alpha-track detection technique. It consists of three parts: the passive detector, the etching unit and the evaluation unit. A CR-39 detector is used as the radiation detector. Alpha-track reading and data analysis are carried out after chemical etching. The following subjects were examined in the present study: (1) radon sensitivity, (2) performance of etching and evaluation processes and (3) thoron sensitivity. The radon sensitivity of 6.9 x 10(-4) mm(-2) (Bq m(-3) d)(-1) was acceptable for practical application. The thoron sensitivity was estimated to be as low as 3.3 x 10(-5) mm(-2) (Bq m(-3) d)(-1) from the experimental study.
Stoffel, T.; Andreas, A.
1981-07-15
The SRRL was established at the Solar Energy Research Institute (now NREL) in 1981 to provide continuous measurements of the solar resources, outdoor calibrations of pyranometers and pyrheliometers, and to characterize commercially available instrumentation. The SRRL is an outdoor laboratory located on South Table Mountain, a mesa providing excellent solar access throughout the year, overlooking Denver. Beginning with the basic measurements of global horizontal irradiance, direct normal irradiance and diffuse horizontal irradiance at 5-minute intervals, the SRRL Baseline Measurement System now produces more than 130 data elements at 1-min intervals that are available from the Measurement & Instrumentation Data Center Web site. Data sources include global horizontal, direct normal, diffuse horizontal (from shadowband and tracking disk), global on tilted surfaces, reflected solar irradiance, ultraviolet, infrared (upwelling and downwelling), photometric and spectral radiometers, sky imagery, and surface meteorological conditions (temperature, relative humidity, barometric pressure, precipitation, snow cover, wind speed and direction at multiple levels). Data quality control and assessment include daily instrument maintenance (M-F) with automated data quality control based on real-time examinations of redundant instrumentation and internal consistency checks using NREL's SERI-QC methodology. Operators are notified of equipment problems by automatic e-mail messages generated by the data acquisition and processing system. Radiometers are recalibrated at least annually with reference instruments traceable to the World Radiometric Reference (WRR).
Choi, William; Tong, Xiuli; Cain, Kate
2016-08-01
This 1-year longitudinal study examined the role of Cantonese lexical tone sensitivity in predicting English reading comprehension and the pathways underlying their relation. Multiple measures of Cantonese lexical tone sensitivity, English lexical stress sensitivity, Cantonese segmental phonological awareness, general auditory sensitivity, English word reading, and English reading comprehension were administered to 133 Cantonese-English unbalanced bilingual second graders. Structural equation modeling analysis identified transfer of Cantonese lexical tone sensitivity to English reading comprehension. This transfer was realized through a direct pathway via English stress sensitivity and also an indirect pathway via English word reading. These results suggest that prosodic sensitivity is an important factor influencing English reading comprehension and that it needs to be incorporated into theoretical accounts of reading comprehension across languages. Copyright © 2016 Elsevier Inc. All rights reserved.
Responsiveness to Intervention in Children with Dyslexia.
Tilanus, Elisabeth A T; Segers, Eliane; Verhoeven, Ludo
2016-08-01
We examined the responsiveness to a 12-week phonics intervention in 54 s-grade Dutch children with dyslexia, and compared their reading and spelling gains to a control group of 61 typical readers. The intervention aimed to train grapheme-phoneme correspondences (GPCs), and word reading and spelling by using phonics instruction. We examined the accuracy and efficiency of grapheme-phoneme correspondences, decoding words and pseudowords, as well as the accuracy of spelling words before and after the intervention. Moreover, responsiveness to intervention was examined by studying to what extent scores at posttest could directly or indirectly be predicted from precursor measures. Results showed that the children with dyslexia were significantly behind in all reading and spelling measures at pretest. During the intervention, the children with dyslexia made more progress on GPC, (pseudo)word decoding accuracy and efficiency, and spelling accuracy than the typical reading group. Furthermore, we found a direct effect of the precursor measures rapid automatized naming, verbal working memory and phoneme deletion on the dyslexic children's progress in GPC speed, and indirect effects of rapid automatized naming and phoneme deletion on word and pseudoword efficiency and word decoding accuracy via the scores at pretest. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Abdelrasoul, Mohamed Mahmoud Ibrahim
2014-01-01
The present study aimed at developing the necessary critical reading skills and social skills of the Egyptian EFL second year preparatory school students, through a proposed program based on using reading circles strategy. The study participants were 44 students from Sohag Experimental Preparatory School in Sohag Governorate. Instruments of the…
ERIC Educational Resources Information Center
Putman, S. Michael
2014-01-01
The Internet is having a profound impact on the literacy practices of today's students. Acknowledging the complex processes associated with reading online, the Survey of Online Reading Attitudes and Behaviors (SORAB) was created to further our understandings in this area. A factor analysis revealed the instrument included five factors that…
Reading Logs and Literature Teaching Models in English Language Teacher Education
ERIC Educational Resources Information Center
Ochoa Delarriva, Ornella; Basabe, Enrique Alejandro
2016-01-01
Reading logs are regularly used in foreign language education since they are not only critical in the development of reading comprehension but may also be instrumental in taking readers beyond the referential into the representational realms of language. In this paper we offer the results of a qualitative analysis of a series of reading logs…
NASA Astrophysics Data System (ADS)
Fantini, Sergio; Hueber, Dennis; Franceschini, Maria Angela; Gratton, Enrico; Rosenfeld, Warren; Stubblefield, Phillip G.; Maulik, Dev; Stankovic, Miljan R.
1999-06-01
We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 µM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intensity (dc slope method). The analysis of the cerebral optical signals associated with the arterial pulse and with respiration demonstrates that motion artefacts can significantly affect the intensity recorded from a single optode pair. Motion artefacts can be strongly reduced by combining data from multiple optodes to provide relative readings in the dc slope method. We also report significant biphasic changes (initial decrease and successive increase) in the reduced scattering coefficient measured in the brain after the piglet had been sacrificed.
24 CFR 4000.2 - Freedom of Information Act.
Code of Federal Regulations, 2010 CFR
2010-04-01
... requests to the Board for access to records of the Board should be directed to the attention of the Board... provided in the regulations in 24 CFR part 15, subpart B. The public reading rooms for the Board are the reading rooms located at HUD Headquarters in Washington, DC. Due to security measures at HUD Headquarters...
Differential cognitive and perceptual correlates of print reading versus braille reading.
Veispak, Anneli; Boets, Bart; Ghesquière, Pol
2013-01-01
The relations between reading, auditory, speech, phonological and tactile spatial processing are investigated in a Dutch speaking sample of blind braille readers as compared to sighted print readers. Performance is assessed in blind and sighted children and adults. Regarding phonological ability, braille readers perform equally well compared to print readers on phonological awareness, better on verbal short-term memory and significantly worse on lexical retrieval. The groups do not differ on speech perception or auditory processing. Braille readers, however, have more sensitive fingers than print readers. Investigation of the relations between these cognitive and perceptual skills and reading performance indicates that in the group of braille readers auditory temporal processing has a longer lasting and stronger impact not only on phonological abilities, which have to satisfy the high processing demands of the strictly serial language input, but also directly on the reading ability itself. Print readers switch between grapho-phonological and lexical reading modes depending on the familiarity of the items. Furthermore, the auditory temporal processing and speech perception, which were substantially interrelated with phonological processing, had no direct associations with print reading measures. Copyright © 2012 Elsevier Ltd. All rights reserved.
Survey of Instrumentation for the Measurement of Stratospheric Trace Gases and Particulates (CIAP)
DOT National Transportation Integrated Search
1971-11-01
A survey was conducted to determine the applicability of presently available instrumentation to the direct and/or remote measure of trace gases and particulates within the stratosphere. Consideration was also given to techniques under development whe...
Reading in Schizophrenic Subjects and Their Nonsymptomatic First-Degree Relatives
Roberts, Eryl O.; Proudlock, Frank A.; Martin, Kate; Reveley, Michael A.; Al-Uzri, Mohammed; Gottlob, Irene
2013-01-01
Previous studies have demonstrated eye movement abnormalities during smooth pursuit and antisaccadic tasks in schizophrenia. However, eye movements have not been investigated during reading. The purpose of this study was to determine whether schizophrenic subjects and their nonsymptomatic first-degree relatives show eye movement abnormalities during reading. Reading rate, number of saccades per line, amplitudes of saccades, percentage regressions (reverse saccades), and fixation durations were measured using an eye tracker (EyeLink, SensoMotoric Instruments, Germany) in 38 schizophrenic volunteers, 14 nonaffected first-degree relatives, and 57 control volunteers matched for age and National Adult Reading Test scores. Parameters were examined when volunteers read full pages of text and text was limited to progressively smaller viewing areas around the point of fixation using a gaze-contingent window. Schizophrenic volunteers showed significantly slower reading rates (P = .004), increase in total number of saccades (P ≤ .001), and a decrease in saccadic amplitude (P = .025) while reading. Relatives showed a significant increase in total number of saccades (P = .013) and decrease in saccadic amplitude (P = .020). Limitation of parafoveal information by reducing the amount of visible characters did not change the reading rate of schizophrenics but controls showed a significant decrease in reading rate with reduced parafoveal information (P < .001). Eye movement abnormalities during reading of schizophrenic volunteers and their first-degree relatives suggest that visual integration of foveal and parafoveal information may be reduced in schizophrenia. Reading abnormalities in relatives suggest a genetic influence in reading ability in schizophrenia and rule out confounding effects of medication. PMID:22267532
Optical character recognition reading aid for the visually impaired.
Grandin, Juan Carlos; Cremaschi, Fabian; Lombardo, Elva; Vitu, Ed; Dujovny, Manuel
2008-06-01
An optical character recognition (OCR) reading machine is a significant help for visually impaired patients. An OCR reading machine is used. This instrument can provide a significant help in order to improve the quality of life of patients with low vision or blindness.
Ten Brug, A; Van der Putten, A A J; Penne, A; Maes, B; Vlaskamp, C
2016-11-01
Multi-sensory storytelling (MSST) was developed to include persons with profound intellectual and multiple disabilities in storytelling culture. In order to increase the listeners' attention, MSST stories are individualised and use multiple sensory stimuli to support the verbal text. In order to determine the value of MSST, this study compared listeners' attention under two conditions: (1) being read MSST books and (2) being read regular stories. A non-randomised control study was executed in which the intervention group read MSST books (n = 45) and a comparison group (n = 31) read regular books. Books were read 10 times during a 5-week period. The 1st, 5th and 10th storytelling sessions were recorded on video in both groups, and the percentage of attention directed to the book and/or stimuli and to the storyteller was scored by a trained and independent rater. Two repeated measure analyses (with the storytelling condition as a between-subject factor and the three measurements as factor) were performed to determine the difference between the groups in terms of attention directed to the book/stimuli (first analysis) and storyteller (second analysis). A further analysis established whether the level of attention changed between the reading sessions and whether there was an interaction effect between the repetition of the book and the storytelling condition. The attention directed to the book and/or the stimuli was significantly higher in the MSST group than in the comparison group. No significant difference between the two groups was found in the attention directed to the storyteller. For MSST stories, most attention was observed during the fifth reading session, while for regular stories, the fifth session gained least attentiveness from the listener. The persons with profound intellectual and multiple disabilities paid more attention to the book and/or stimuli in the MSST condition compared with the regular story telling group. Being more attentive towards the book and stimuli might give persons with PIMD the opportunity to apprehend the story and to be included in storytelling culture. © 2016 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.
OIFITS 2: the 2nd version of the data exchange standard for optical interferometry
NASA Astrophysics Data System (ADS)
Duvert, Gilles; Young, John; Hummel, Christian A.
2017-01-01
This paper describes version 2 of the Optical Interferometry exchange Format (OIFITS), the standard for exchanging calibrated data from optical (visible or infrared) interferometers. This IAU-endorsed standard has been in use for 10 years at most of the past and current optical interferometer projects, including COAST, NPOI, IOTA, CHARA, VLTI, PTI and the Keck interferometer. Software is available for reading, writing and merging OIFITS files. This version 2 provides definitions of additional data tables (for example for polarisation measurements), addressing the needs of future interferometric instruments. Also included are data columns for a more rigorous description of measurement errors and their correlations. In that, this document is a step towards the design of a common data model for optical interferometry. Finally, the main OIFITS header is expanded with several new keywords summarising the content to allow doing data base searches. We request that comments and suggestions related to OIFITS be directed to the OLBIN email list. (See http://www.jmmc.fr/olbin-forum for information on how to subscribe and post to the list.)
Galuschka, Katharina; Rothe, Josefine; Schulte-Körne, Gerd
2015-09-01
This article looks at a means of objectively evaluating the quality of psychometric tests. This approach enables users to evaluate psychometric tests based on their methodological characteristics, in order to decide which instrument should be used. Reading and spelling assessment tools serve as examples. The paper also provides a review of German psychometric tests for the assessment of reading and spelling skills. This method facilitates the identification of psychometric tests.of high methodological quality which can be used for the assessment of reading and spelling skills. Reading performance should ideally be assessed with the following instruments: ELFE 1-6, LGVT 6-12, LESEN 6-7, LESEN 8-9, or WLLP-R. The tests to be used for the evaluation of spelling skills are DERET 1-2+, DERET 3-4+, WRT 1+, WRT 2+, WRT 3+, WRT 4+ or HSP 1-10.
Balaguru, Duraisamy; Rodriguez, Matthew; Leon, Stephanie; Wagner, Louis K; Beasley, Charles W; Sultzer, Andrew; Numan, Mohammed T
2018-01-01
Objectives: Direct measurement of skin dose of radiation for children using optically stimulated luminescence (OSL) technology using nanoDot® (Landauer, Glenwood, IL, USA). Background: Radiation dose is estimated as cumulative air kerma (AK) and dosearea product based on standards established for adult size patients. Body size of pediatric patients who undergo cardiac catheterization for congenital heart disease vary widely from newborn to adolescence. Direct, skindose measurement applying OSL technology may eliminate errors in the estimate. Materials and Methods: The nanoDot® (1 cm × 1 cm × flat plastic cassette) is applied to patient's skin using adhesive tape during cardiac catheterization and radiation skin doses were read within 24 hrs. nanoDot® values were compared to the currently available cumulative AK values estimated and displayed on fluoroscopy monitor. Results: A total of 12 children were studied, aged 4 months to 18 years (median 1.1 years) and weight range 5.3–86 kg (median 8.4 kg). nanoDot® readings ranged from 2.58 mGy to 424.8 mGy (median 84.1 mGy). Cumulative AK ranged from 16.2 mGy to 571.2 mGy (median 171.1 mGy). Linear correlation was noted between nanoDot® values and AK values (R2 = 0.88, R = 0.94). nanoDot® readings were approximately 65% of the estimated cumulative AK estimated using the International Electrotechnical Commission standards. Conclusions: Application of OSL technology using nanoDot® provides an alternative to directly measure fluoroscopic skin dose in children during cardiac catheterization. Our data show that the actual skin dose for children is approximately one-third lower than the AK estimated using international standards for adult size patients. PMID:29440825
Balaguru, Duraisamy; Rodriguez, Matthew; Leon, Stephanie; Wagner, Louis K; Beasley, Charles W; Sultzer, Andrew; Numan, Mohammed T
2018-01-01
Direct measurement of skin dose of radiation for children using optically stimulated luminescence (OSL) technology using nanoDot ® (Landauer, Glenwood, IL, USA). Radiation dose is estimated as cumulative air kerma (AK) and dosearea product based on standards established for adult size patients. Body size of pediatric patients who undergo cardiac catheterization for congenital heart disease vary widely from newborn to adolescence. Direct, skindose measurement applying OSL technology may eliminate errors in the estimate. The nanoDot ® (1 cm × 1 cm × flat plastic cassette) is applied to patient's skin using adhesive tape during cardiac catheterization and radiation skin doses were read within 24 hrs. nanoDot ® values were compared to the currently available cumulative AK values estimated and displayed on fluoroscopy monitor. A total of 12 children were studied, aged 4 months to 18 years (median 1.1 years) and weight range 5.3-86 kg (median 8.4 kg). nanoDot® readings ranged from 2.58 mGy to 424.8 mGy (median 84.1 mGy). Cumulative AK ranged from 16.2 mGy to 571.2 mGy (median 171.1 mGy). Linear correlation was noted between nanoDot® values and AK values ( R 2 = 0.88, R = 0.94). nanoDot® readings were approximately 65% of the estimated cumulative AK estimated using the International Electrotechnical Commission standards. Application of OSL technology using nanoDot® provides an alternative to directly measure fluoroscopic skin dose in children during cardiac catheterization. Our data show that the actual skin dose for children is approximately one-third lower than the AK estimated using international standards for adult size patients.
Book reading styles in dual-parent and single-mother families.
Blake, Joanna; Macdonald, Silvana; Bayrami, Lisa; Agosta, Vanessa; Milian, Andrea
2006-09-01
Whereas many studies have investigated quantitative aspects of book reading (frequency), few have examined qualitative aspects, especially in very young children and through direct observations of shared reading. The purpose of this study was to determine possible differences in book-reading styles between mothers and fathers and between mothers from single- and dual-parent families. It also related types of parental verbalizations during book reading to children's reported language measures. Dual-parent (29) and single-parent (24) families were observed in shared book reading with their toddlers (15-month-olds) or young preschoolers (27-month-olds). Parent-child dyads were videotaped while book reading. The initiator of each book-reading episode was coded. Parents' verbalizations were exhaustively coded into 10 categories. Mothers completed the MacArthur Communicative Development Inventory, and the children were given the Bayley scales. All parents differentiated their verbalizations according to the age rather than the gender of the child, but single mothers imitated female children more than males. Few differences in verbalizations were found between mothers and fathers or between mothers from single- and dual-parent families. Fathers allowed younger children to initiate book-reading episodes more than mothers. For both age groups of children, combined across families, verbalizations that related the book to the child's experience were correlated with reported language measures. Questions and imitations were related to language measures for the older age group. The important types of parental verbalizations during shared book reading for children's language acquisition are relating, questions and imitations.
Quality of health literacy instruments used in children and adolescents: a systematic review.
Guo, Shuaijun; Armstrong, Rebecca; Waters, Elizabeth; Sathish, Thirunavukkarasu; Alif, Sheikh M; Browne, Geoffrey R; Yu, Xiaoming
2018-06-14
Improving health literacy at an early age is crucial to personal health and development. Although health literacy in children and adolescents has gained momentum in the past decade, it remains an under-researched area, particularly health literacy measurement. This study aimed to examine the quality of health literacy instruments used in children and adolescents and to identify the best instrument for field use. Systematic review. A wide range of settings including schools, clinics and communities. Children and/or adolescents aged 6-24 years. Measurement properties (reliability, validity and responsiveness) and other important characteristics (eg, health topics, components or scoring systems) of health literacy instruments. There were 29 health literacy instruments identified from the screening process. When measuring health literacy in children and adolescents, researchers mainly focus on the functional domain (basic skills in reading and writing) and consider participant characteristics of developmental change (of cognitive ability), dependency (on parents) and demographic patterns (eg, racial/ethnic backgrounds), less on differential epidemiology (of health and illness). The methodological quality of included studies as assessed via measurement properties varied from poor to excellent. More than half (62.9%) of measurement properties were unknown, due to either poor methodological quality of included studies or a lack of reporting or assessment. The 8-item Health Literacy Assessment Tool (HLAT-8) showed best evidence on construct validity, and the Health Literacy Measure for Adolescents showed best evidence on reliability. More rigorous and high-quality studies are needed to fill the knowledge gap in measurement properties of health literacy instruments. Although it is challenging to draw a robust conclusion about which instrument is the most reliable and the most valid, this review provides important evidence that supports the use of the HLAT-8 to measure childhood and adolescent health literacy in future school-based research. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Health Literacy and Cancer Prevention: Two New Instruments to Assess Comprehension
Mazor, Kathleen M.; Roblin, Douglas W.; Williams, Andrew E.; Greene, Sarah M.; Gaglio, Bridget; Field, Terry S.; Costanza, Mary E.; Han, Paul K. J.; Saccoccio, Laura; Calvi, Josephine; Cove, Erica; Cowan, Rebecca
2012-01-01
Objectives Ability to understand spoken health information is an important facet of health literacy, but to date, no instrument has been available to quantify patients’ ability in this area. We sought to develop a test to assess comprehension of spoken health messages related to cancer prevention and screening to fill this gap, and a complementary test of comprehension of written health messages. Methods We used the Sentence Verification Technique to write items based on realistic health messages about cancer prevention and screening, including media messages, clinical encounters and clinical print materials. Items were reviewed, revised, and pre-tested. Adults aged 40 to 70 participated in a pilot administration in Georgia, Hawaii, and Massachusetts. Results The Cancer Message Literacy Test-Listening is self-administered via touchscreen laptop computer. No reading is required. It takes approximately 1 hour. The Cancer Message Literacy Test-Reading is self-administered on paper. It takes approximately 10 minutes. Conclusions These two new tests will allow researchers to assess comprehension of spoken health messages, to examine the relationship between listening and reading literacy, and to explore the impact of each form of literacy on health-related outcomes. Practice Implications Researchers and clinicians now have a means of measuring comprehension of spoken health information. PMID:22244323
NASA Technical Reports Server (NTRS)
1990-01-01
Evaluations are summarized directed towards defining optimal instrumentation for performing planetary polarization measurements from a spacecraft platform. An overview of the science rationale for polarimetric measurements is given to point out the importance of such measurements for future studies and exploration of the outer planets. The key instrument features required to perform the needed measurements are discussed and applied to the requirements for the Cassini mission to Saturn. The resultant conceptual design of a spectro-polarimeter photometer for Cassini is described in detail.
High-precision ground-based photometry of exoplanets
NASA Astrophysics Data System (ADS)
de Mooij, Ernst J. W.; Jayawardhana, Ray
2013-04-01
High-precision photometry of transiting exoplanet systems has contributed significantly to our understanding of the properties of their atmospheres. The best targets are the bright exoplanet systems, for which the high number of photons allow very high signal-to-noise ratios. Most of the current instruments are not optimised for these high-precision measurements, either they have a large read-out overhead to reduce the readnoise and/or their field-of-view is limited, preventing simultaneous observations of both the target and a reference star. Recently we have proposed a new wide-field imager for the Observatoir de Mont-Megantic optimised for these bright systems (PI: Jayawardhana). The instruments has a dual beam design and a field-of-view of 17' by 17'. The cameras have a read-out time of 2 seconds, significantly reducing read-out overheads. Over the past years we have obtained significant experience with how to reach the high precision required for the characterisation of exoplanet atmospheres. Based on our experience we provide the following advice:
Development of a drift-correction procedure for a direct-reading spectrometer
NASA Technical Reports Server (NTRS)
Chapman, G. B., II; Gordon, W. A.
1977-01-01
A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.
ERIC Educational Resources Information Center
Buhs, Eric S.; Welch, Greg; Burt, Jennifer; Knoche, Lisa
2011-01-01
This study evaluated a data-set drawn using "The Familia"--a measure originally developed to evaluate shared-reading activities. A newly developed set of conceptual supports and a confirmatory factor analysis (CFA) were applied to a new factor structure/model. Data were drawn from 219 young children and their families (mean age = 43…
ERIC Educational Resources Information Center
Dahl, Gordon; Lochner, Lance
2008-01-01
Past estimates of the effect of family income on child development have often been plagued by endogeneity and measurement error. In this paper, we use two simulated instrumental variables strategies to estimate the causal effect of income on children's math and reading achievement. Our identification derives from the large, non-linear changes in…
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Pumps, valves, connectors, and...) Monitoring method. Unless otherwise specified in § 63.1002(b), or § 63.1016, the owner or operator shall... instrument reading of 10,000 parts per million or greater is measured, a leak is detected. If a leak is...
ERIC Educational Resources Information Center
Putman, S. Michael; Wang, Chuang; Ki, Seryeong
2015-01-01
The Internet is having a profound impact on the literacy practices of students worldwide; yet, there are few instruments available to facilitate cross-cultural comparisons and conclusions specific to cognitive and affective variables related to Internet proficiency. This research was conducted to examine the measurement invariance of the…
ERIC Educational Resources Information Center
Dahl, Gordon; Lochner, Lance
2009-01-01
Past estimates of the effect of family income on child development have often been plagued by endogeneity and measurement error. In this paper, we use two simulated instrumental variables strategies to estimate the causal effect of income on children's math and reading achievement. Our identification derives from the large, non-linear changes…
The Impact of Intensive Reading Intervention on Level of Attention in Middle School Students.
Roberts, Greg; Rane, Shruti; Fall, Anna-Mária; Denton, Carolyn A; Fletcher, Jack M; Vaughn, Sharon
2015-01-01
The purpose of the study was to estimate the impact of reading intervention on ratings of student attention over time. We used extant data from a longitudinal randomized study of a response-based reading intervention to fit a multiple-indicator, multilevel growth model. The sample at randomization was 54% male, 18% limited English proficient, 85% eligible for free or reduced-price lunch, 58% African American, and 32% Hispanic. Reading ability was measured by using the Woodcock-Johnson III Tests of Achievement. Attention was measured by using the Strengths and Weaknesses of ADHD Symptoms and Normal Behavior Scale. Findings indicate that intensive, response-based reading intervention over 3 years improved reading achievement and behavioral attention in middle school struggling readers, with treatment directly affecting reading, which in turn influenced attention. In the business-as-usual condition, there was no relation between improved reading and attention. The results are consistent with a correlated liabilities model of comorbidity. The results do not align with the inattention-as-cause hypothesis, which predicts that reading intervention should not affect attention. The findings do not support, but do not necessarily preclude, the phenocopy hypothesis. The results are especially pertinent for older students who may be inattentive partly because of years of struggling with reading.
The Impact of Intensive Reading Intervention on Level of Attention in Middle School Students
Roberts, Greg; Rane, Shruti; Fall, Anna-Mária; Denton, Carolyn A.; Fletcher, Jack M.; Vaughn, Sharon
2014-01-01
Objective The purpose of the study was to estimate the impact of reading intervention on ratings of student attention over time. Method We used extant data from a longitudinal randomized study of a response-based reading intervention to fit a multiple-indicator, multilevel growth model. The sample at randomization was 54% male, 18% limited English proficient, 85% eligible for free or reduced-price lunch, 58% African American, and 32% Hispanic. Reading ability was measured by using the Woodcock-Johnson III Tests of Achievement. Attention was measured by using the Strengths and Weaknesses of ADHD Symptoms and Normal Behavior Scale. Results Findings indicate that intensive, response-based reading intervention over 3 years improved reading achievement and behavioral attention in middle school struggling readers, with treatment directly affecting reading, which in turn influenced attention. In the business-as-usual condition, there was no relation between improved reading and attention. Conclusions The results are consistent with a correlated liabilities model of comorbidity. The results do not align with the inattention-as-cause hypothesis, which predicts that reading intervention should not affect attention. The findings do not support, but do not necessarily preclude, the phenocopy hypothesis. The results are especially pertinent for older students who may be inattentive partly because of years of struggling with reading. PMID:24885289
Measurement of the acoustic response of a wind instrument with application to bore reconstruction
NASA Astrophysics Data System (ADS)
van Walstijn, Maarten; Campbell, Murray
2002-11-01
Reconstruction of a bore from measured acoustic response data has been shown to be very useful in studying wind instruments. Such data may be obtained in different ways; directly measuring the frequency-domain response of an acoustic bore has some distinct advantages over directly measuring time-domain data (for example, by pulse reflectometry), but so far has been unsuitable for producing input data for deterministic bore reconstruction algorithms, due to the limited accuracy at high frequencies. In this paper a method is presented for large-bandwidth measurement of the input impedance of a wind instrument using a cylindrical measurement head with multiple wall-mounted microphones. The influence of the number of microphones and the types of calibration impedance on the accuracy will be discussed, and bore reconstructions derived using this technique will be compared with reconstructions obtained using pulse reflectometry. [Work supported by EPSRC.
Localization Grid for Accurate Positioning Onboard a Carrier
2017-06-30
the fi r t I 00 reads. It is clear that the RSSI measurement varies significantly over the different reads. It hould also be noted that, fo r the...yield a complete characterization of RSSI with respect to di stance and tag direction. By fi tting equation ( l .5) to the experimental data for di...For each observation in tant t, we feed the ML estimates of the instantaneous reader position as a fi fi [ " T T ]T h " T measurement to the Kalman
NASA Technical Reports Server (NTRS)
Acton, Charles H., Jr.; Bachman, Nathaniel J.; Semenov, Boris V.; Wright, Edward D.
2010-01-01
The Navigation Ancillary Infor ma tion Facility (NAIF) at JPL, acting under the direction of NASA s Office of Space Science, has built a data system named SPICE (Spacecraft Planet Instrument Cmatrix Events) to assist scientists in planning and interpreting scientific observations (see figure). SPICE provides geometric and some other ancillary information needed to recover the full value of science instrument data, including correlation of individual instrument data sets with data from other instruments on the same or other spacecraft. This data system is used to produce space mission observation geometry data sets known as SPICE kernels. It is also used to read SPICE kernels and to compute derived quantities such as positions, orientations, lighting angles, etc. The SPICE toolkit consists of a subroutine/ function library, executable programs (both large applications and simple utilities that focus on kernel management), and simple examples of using SPICE toolkit subroutines. This software is very accurate, thoroughly tested, and portable to all computers. It is extremely stable and reusable on all missions. Since the previous version, three significant capabilities have been added: Interactive Data Language (IDL) interface, MATLAB interface, and a geometric event finder subsystem.
Size-of-source Effect in Infrared Thermometers with Direct Reading of Temperature
NASA Astrophysics Data System (ADS)
Manoi, A.; Saunders, P.
2017-07-01
The size-of-source effect (SSE) for six infrared (IR) thermometers with direct reading of temperature was measured in this work. The alternative direct method for SSE determination, where the aperture size is fixed and the measurement distance is varied, was used in this study. The experimental equivalence between the usual and the alternative direct methods is presented. The magnitudes of the SSE for different types of IR thermometers were investigated. The maxima of the SSE were found to be up to 5 %, 8 %, and 28 % for focusable, closed-focus, and open-focus thermometers, respectively. At 275°C, an SSE of 28 % corresponds to 52°C, indicating the severe effect on the accuracy of this type of IR thermometer. A method to realize the calibration conditions used by the manufacturer, in terms of aperture size and measurement distance, is discussed and validated by experimental results. This study would be of benefit to users in choosing the best IR thermometer to match their work and for calibration laboratories in selecting the technique most suitable for determining the SSE.
ERIC Educational Resources Information Center
Chiu, Shao-I; Hong, Fu-Yuan; Hu, Hsiu-yuan
2015-01-01
This study proposed and tested a structural model of the effects of family cultural capital and reading motivation on reading behaviour in elementary school students. Participants were 467 fifth and sixth graders from elementary schools in Changhua County, Taiwan. The instruments employed in this study included the Family Cultural Capital Scale,…
NASA Technical Reports Server (NTRS)
Brun, Rinaldo J.; Levine, Joseph; Kleinknecht, Kenneth S.
1951-01-01
A flight instrument that uses electric means for measuring the droplet-size distribution in above-freezing clouds has been devised and given preliminary evaluation in flight. An electric charge is placed on the droplets and they are separated aerodynamically according to their mass. Because the charge placed on the droplets is a. function of the droplet size, the size spectrum can 'be determined by measurement of the charge deposited on cylinders of several different sizes placed to intercept the charged droplets. An expression for the rate of charge acquisition by a water droplet in a field of coronal discharge is derived. The results obtained in flight with an instrument based on the method described indicate that continuous records of droplet-size spectrum variations in clouds can be obtained. The experimental instrument was used to evaluate the method and was not refined to the extent necessary for obtaining conclusive meteorological data. The desirable features of an instrument based on the method described are (i) The instrument can be used in clouds with temperatures above freezing; (2) the size and the shape of the cylinders do not change during the exposure time; (3) the readings are instantaneous and continuous; (4) the available sensitivity permits the study of variations in cloud structures of less than 200 feet in extent.
Ignacio-García, José M; Ignacio-García, Juan M; Almenara-Barrios, José; Chocrón-Giraldez, María J; Hita-Iglesias, Carmen
2005-01-01
Because most bronchodilator inhalers contain propellant gases or a small amount of ethanol as a co-solvent, the potential for these products to generate false readings on a evidential breath alcohol instrument was evaluated in 69 volunteers with clinically stable asthma. All subjects underwent a breath test on an infrared breath alcohol analyzer (Alcotest 7110, Dräger, Lübeck, Germany) before the use of the asthma inhaler and 1 and 5 min after inhalation. The effects of antiasthmatic medications delivered by metered dose inhalers (MDIs) with alcohol as a vehicle, alcohol-free MDIs, and dry powder inhalers were assessed in homogeneous groups of four to five patients. All subjects were alcohol-free on the preliminary breath test. One minute after inhalation, negative readings were only observed in 25 (36.2%) of subjects. In 62.3% of patients, apparent alcohol results were considered interferences or unstable readings by the breath-test instrument. One subject showed a final positive breath alcohol level (0.07 mg/L). After the use of dry powder inhalers, valid results without interferences were obtained. However, 89.6% of patients in which bronchodilators were delivered by MDIs (with propellant gases in the aerosol) showed altered partial readings and labeled the final output as "invalid," but tests performed 5 min after the use of inhalers were valid and correct in all cases. MDIs with propellants as a vehicle may cause false positive breath alcohol readings in some patients. These effects are transient and may be prevented by a 5-10-min interval between the use of MDIs and breath alcohol testing.
Brenner, Sara A; Neu-Baker, Nicole M; Eastlake, Adrienne C; Beaucham, Catherine C; Geraci, Charles L
2016-11-01
The ubiquitous use of engineered nanomaterials-particulate materials measuring approximately 1-100 nanometers (nm) on their smallest axis, intentionally engineered to express novel properties-in semiconductor fabrication poses unique issues for protecting worker health and safety. Use of new substances or substances in a new form may present hazards that have yet to be characterized for their acute or chronic health effects. Uncharacterized or emerging occupational health hazards may exist when there is insufficient validated hazard data available to make a decision on potential hazard and risk to exposed workers under condition of use. To advance the knowledge of potential worker exposure to engineered nanomaterials, the National Institute for Occupational Safety and Health Nanotechnology Field Studies Team conducted an on-site field evaluation in collaboration with on-site researchers at a semiconductor research and development facility on April 18-21, 2011. The Nanomaterial Exposure Assessment Technique (2.0) was used to perform a complete exposure assessment. A combination of filter-based sampling and direct-reading instruments was used to identify, characterize, and quantify the potential for worker inhalation exposure to airborne alumina and amorphous silica nanoparticles associated with th e chemical mechanical planarization wafer polishing process. Engineering controls and work practices were evaluated to characterize tasks that might contribute to potential exposures and to assess existing engineering controls. Metal oxide structures were identified in all sampling areas, as individual nanoparticles and agglomerates ranging in size from 60 nm to >1,000 nm, with varying structure morphology, from long and narrow to compact. Filter-based samples indicated very little aerosolized material in task areas or worker breathing zone. Direct-reading instrument data indicated increased particle counts relative to background in the wastewater treatment area; however, particle counts were very low overall, indicating a well-controlled working environment. Recommendations for employees handling or potentially exposed to engineered nanomaterials include hazard communication, standard operating procedures, conservative ventilation systems, and prevention through design in locations where engineered nanomaterials are used or stored, and routine air sampling for occupational exposure assessment and analysis.
Carlton, Jill
2013-10-22
Amblyopia is a visual condition that occurs in childhood. Screening programmes exist within the United Kingdom (UK) to detect amblyopia, and once detected treatment is given.Existing patient reported outcome (PRO) measures for amblyopia do not meet current recommendations for the methods adopted during their development, or the way in which the instruments are administered. The overall aim of this study was to produce a self-complete PRO instrument for amblyopia for children aged 4-7 years that uses children's responses in the development phase. The study comprised a number of stages. This paper reports on the refinement of the descriptive system for the draft instrument (the Child Amblyopia Treatment Questionnaire, CAT-QoL) using qualitative and quantitative methods. The study consisted of three components. Children were asked to read, and complete the draft questionnaire as independently as possible. They were then asked about the questionnaire, and its format, in a cognitive debriefing exercise. Observations were made as to the child's ability to read the questionnaire, particular attention was made as to which individual words participants struggled to read. Children were also asked their opinion on the design layout of the questionnaire. Finally, some children were asked to complete a ranking task to help determine the order of the levels of the items as judged by the children. Mid-rank scoring and statistical level of agreement were calculated for the ranking exercise. Thirty-two (n=32) participants completed a draft questionnaire; each of these underwent a cognitive de-briefing interview. Twenty-two (n=22) children completed the ranking exercise. Ten children did not understand the concept of ranking. The results of the qualitative phase (cognitive de-briefing interview) were used to modify the wording of items and layout of the instrument. Results of the ranking exercise were used to inform the order of the response levels for the items. Responses of young children can be used in the development of PRO instruments. They are able to help inform the content, wording, and format of an instrument, ensuring good content and face validity. The results have been used to further refine the CAT-QoL, however further research is required to assess the psychometric properties of the instrument.
1951-05-01
prccedur&:s to be of hipn accuracy. Ambij;uity of subject responizes due to overlap of entries on tU,, record sheets vas negligible. Handwriting ...experimental variables on reading errors us carried out by analysis of variance methods. For this purpose it was convenient to consider different classes...on any scale - an error ofY one numbered division. For this reason, the result. of the analysis of variance of the /10’s errors by dial types may
Reading direction shifts visuospatial attention: an Interactive Account of attentional biases.
Rinaldi, Luca; Di Luca, Samuel; Henik, Avishai; Girelli, Luisa
2014-09-01
A growing amount of evidence confirms the influence of reading and writing habits on visuospatial processing, although this phenomenon has been so far testified mainly as a lateralized shift of a single behavioral sign (e.g., line bisection), with lack of proof from pure right-to-left readers. The present study contributed to this issue by analyzing multiple attentional and motor indexes in monolingual Italian (i.e., reading from left-to-right), and monolingual (i.e., reading from right-to-left) and bilingual Israeli (i.e., reading from right-to-left in Hebrew but also from left-to-right in English) participants' visuospatial performance. Subjects were administered a computerized standard star cancellation task and a modified version in which English letters and words were replaced by Hebrew ones. Tasks were presented on a graphics tablet, allowing recording of both chronometric and spatial parameters (i.e., measured in (x, y) vector coordinates). Results showed that reading direction modulated the on-line visuomotor performance (i.e., left-to-right vs. right-to-left shifts) from the beginning (i.e., first mark) to the end of the task (i.e., spatial distribution of omissions and subjective epicenter). Additionally, the spatial bias observed in a computerized line bisection task was also related to the participants' habitual reading direction. Overall, the results favor the proposal of an Interactive Account of visuospatial asymmetries, according to which both cultural factors, such as the directional scanning associated with language processing, and biological factors, such as hemispheric specialization, modulate visuospatial processing. Results are discussed in light of recent behavioral and neuroanatomical findings. Copyright © 2014 Elsevier B.V. All rights reserved.
Movie for the Assessment of Social Cognition (MASC): Spanish validation.
Lahera, G; Boada, L; Pousa, E; Mirapeix, I; Morón-Nozaleda, G; Marinas, L; Gisbert, L; Pamiàs, M; Parellada, M
2014-08-01
We present the Spanish validation of the "Movie for the Assessment of Social Cognition" instrument (MASC-SP). We recruited 22 adolescents and young adults with Asperger syndrome and 26 participants with typical development. The MASC-SP and three other social cognition instruments (Ekman Pictures of Facial Affect test, Reading the Mind in the Eyes Test, and Happé's Strange Stories) were administered to both groups. Individuals with Asperger syndrome had significantly lower scores in all measures of social cognition. The MASC-SP showed strong correlations with all three measures and relative independence of general cognitive functions. Internal consistency was optimal (0.86) and the test-retest was good. The MASC-SP is an ecologically valid and useful tool for assessing social cognition in the Spanish population.
Microcontrollers for data logging in Environmental Physics
NASA Astrophysics Data System (ADS)
Harrison, R. Giles; Westbrook, Christopher. D.
2016-04-01
Methods for obtaining reliable environmental measurements are central in developing a quantitative understanding of the natural world [1]. In the environmental sciences, data is usually obtained through planned experimental work, by collaborators in large field experiments or merely from others downloaded through the internet. Careful appreciation of the provenance and reliability of measurements has traditionally been a central aspect of physics education, and a similar physics-centred approach to measurements has been embedded in the new Environmental Physics BSc programme at the University of Reading [2]. Through the use of practical classes, students are educated in using small programmable microcontroller devices to obtain environmental data. The classes are based around exploring the open source Arduino, to which a range of analogue and digital sensors are connected and evaluated. A simplified prototyping system has been developed to help emphasise the measurement aspects over the electronics considerations. The practical classes work towards deployment of a miniature data logger based on the Arduino's microcontroller but optimised for low power, from which the environmental measurements are compared with co-located standard data obtained at the Reading University Atmospheric Observatory. [1] R.G. Harrison, Meteorological Measurements and Instrumentation, Wiley, 2014. (http://eu.wiley.com/WileyCDA/WileyTitle/productCd-1118745809.html) [2] Environmental Physics BSc (https://www.reading.ac.uk/ready-to-study/study/subject-area/environment-ug/bsc-environmental-physics.aspx)
Frequency division multiplexed readout of TES detectors with baseband feedback
NASA Astrophysics Data System (ADS)
den Hartog, R.; Audley, M. D.; Beyer, J.; Bruijn, M. P.; de Korte, P.; Gottardi, L.; Hijmering, R.; Jackson, B.; Nieuwenhuizen, A.; van der Kuur, J.; van Leeuwen, B.-J.; Van Loon, D.
2012-09-01
SRON is developing an electronic system for the multiplexed read-out of an array of transition edge sensors (TES) by combining the techniques of frequency domain multiplexing (FDM) with base-band feedback (BBFB). The astronomical applications are the read-out of soft X-ray microcalorimeters and the far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In this paper we derive the requirements for the read-out system regarding noise and dynamic range in the context of the SAFARI instrument, and demonstrate that the current experimental prototype is capable of simultaneously locking 57 channels and complies with these requirements.
NASA Astrophysics Data System (ADS)
Rahmawati, P.; Prajitno, P.
2018-04-01
Vibration monitoring is a measurement instrument used to identify, predict, and prevent failures in machine instruments[6]. This is very needed in the industrial applications, cause any problem with the equipment or plant translates into economical loss and they are mostly monitored component off-line[2]. In this research, a system has been developed to detect the malfunction of the components of Shimizu PS-128BT water pump machine, such as capacitor, bearing and impeller by online measurements. The malfunction components are detected by taking vibration data using a Micro-Electro-Mechanical System(MEMS)-based accelerometer that are acquired by using Raspberry Pi microcomputer and then the data are converted into the form of Relative Power Ratio(RPR). In this form the signal acquired from different components conditions have different patterns. The collected RPR used as the base of classification process for recognizing the damage components of the water pump that are conducted by Artificial Neural Network(ANN). Finally, the damage test result will be sent via text message using GSM module that are connected to Raspberry Pi microcomputer. The results, with several measurement readings, with each reading in 10 minutes duration for each different component conditions, all cases yield 100% of accuracies while in the case of defective capacitor yields 90% of accuracy.
47 CFR 73.57 - Remote reading antenna and common point ammeters.
Code of Federal Regulations, 2010 CFR
2010-10-01
... remote leads to the indicating instruments. (2) Inductive coupling to radio frequency current sensing... 47 Telecommunication 4 2010-10-01 2010-10-01 false Remote reading antenna and common point... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.57 Remote reading antenna and common...
A Report on IRI Scoring and Interpretation.
ERIC Educational Resources Information Center
Anderson, Betty
Noting that most classroom teachers use informal reading inventories (IRI) as diagnostic instruments, a study examined what oral reading accuracy level is most appropriate for the instructional level and whether repetitions should be counted as oral reading errors. Randomly selected students from the second through fifth grades at two elementary…
Psycholinguistics, Sociolinguistics, Reading and the Classroom Teacher.
ERIC Educational Resources Information Center
Robinson, H. Alan
Any reputable approach to the teaching of reading makes use of certain psycholinguistic and sociolinguistic concepts which can provide the teacher with insights for the development and strengthening of reading skills. An understanding of the respect for the learner's cultural and behavioral patterns can establish group empathy, instrumental as a…
Karakuła-Juchnowicz, Hanna; Stecka, Mariola
2017-08-29
In view of unavailability in Poland of the standardized methods to measure PIQ, the aim of the work was to develop a Polish test to assess the premorbid level of intelligence - PART(Polish AdultReading Test) and to measureits psychometric properties, such as validity, reliability as well as standardization in the group of schizophrenia patients. The principles of PART construction were based on the idea of popular worldwide National Adult Reading Test by Hazel Nelson. The research comprised a group of 122 subjects (65 schizophrenia patients and 57 healthy people), aged 18-60 years, matched for age and gender. PART appears to be a method with high internal consistency and reliability measured by test-retest, inter-rater reliability, and the method with acceptable diagnostic and prognostic validity. The standardized procedures of PART have been investigated and described. Considering the psychometric values of PART and a short time of its performance, the test may be a useful diagnostic instrument in the assessment of premorbid level of intelligence in a group of schizophrenic patients.
NASA Technical Reports Server (NTRS)
Lupton, W. F.; Conrad, A. R.
1992-01-01
KTL is a set of routines which eases the job of writing applications which must interact with a variety of underlying sub-systems (known as services). A typical application is an X Window user interface coordinating telescope and instruments. In order to connect to a service, application code specifies a service name--typically an instrument name--and a style, which defines the way in which the application will interact with the service. Two styles are currently supported: keyword, where the application reads and writes named keywords and the resulting inter-task message traffic is hidden; and message, where the application deals directly with messages. The keyword style is intended mainly for user interfaces, and the message style is intended mainly for lower-level applications. KTL applications are event driven: a typical application first connects to all its desired services, then expresses interest in specified events. The application then enters an event dispatch loop in which it waits for events and calls the appropriate service's event-handling routine. Each event is associated with a call-back routine which is invoked when the event occurs. Call-back routines may (and typically do) interact with other sub-systems and KTL provides the means of doing so without blocking the application (vital for X Window user interfaces). This approach is a marriage of ideas culled from the X window, ADAM, Keck instrument, and Keck telescope control systems. A novel feature of KTL is that it knows nothing about any services or styles. Instead it defines a generic set of routines which must be implemented by all services and styles (essentially open(), ioctl(), read(), write(), event(), and close()) and activates sharable libraries at run-time. Services have been implemented (in both keyword and message styles) for HIRES (the Keck high resolution echelle spectrograph built by Lick Observatory), LWS (the Keck long wavelength spectrometer built by UC San Diego), and the Keck telescope. Each of these implementations uses different underlying message systems: the Lick MUSIC system, RPC's, and direct sockets (respectively). Services for the remaining three front-line Keck instruments will be implemented over the next few months.
The Sentinel-4 detectors: architecture and performance
NASA Astrophysics Data System (ADS)
Skegg, Michael P.; Hermsen, Markus; Hohn, Rüdiger; Williges, Christian; Woffinden, Charles; Levillain, Yves; Reulke, Ralf
2017-09-01
The Sentinel-4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program. SENTINEL-4 will provide accurate measurements of trace gases from geostationary orbit, including key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Key to achieving these atmospheric measurements are the two CCD detectors, covering the wavelengths in the ranges 305 nm to 500 nm (UVVIS) and 750 to 775 nm (NIR) respectively. The paper describes the architecture, and operation of these two CCD detectors, which have an unusually high full-well capacity and a very specific architecture and read-out sequence to match the requirements of the Sentinel- 4 instrument. The key performance aspects and their verification through measurement are presented, with a focus on an unusual, bi-modal dark signal generation rate observed during test.
Friedman, Daniela B; Hoffman-Goetz, Laurie
2006-06-01
Adequate functional literacy skills positively influence individuals' ability to take control of their health. Print and Web-based cancer information is often written at difficult reading levels. This systematic review evaluates readability instruments (FRE, F-K, Fog, SMOG, Fry) used to assess print and Web-based cancer information and word recognition and comprehension tests (Cloze, REALM, TOFHLA, WRAT) that measure people's health literacy. Articles on readability and comprehension instruments explicitly used for cancer information were assembled by searching MEDLINE and Psyc INFO from 1993 to 2003. In all, 23 studies were included; 16 on readability, 6 on comprehension, and 1 on readability and comprehension. Of the readability investigations, 14 focused on print materials, and 2 assessed Internet information. Comprehension and word recognition measures were not applied to Web-based information. None of the formulas were designed to determine the effects of visuals or design factors that could influence readability and comprehension of cancer education information.
Mars Science Laboratory relative humidity observations: Initial results.
Harri, A-M; Genzer, M; Kemppinen, O; Gomez-Elvira, J; Haberle, R; Polkko, J; Savijärvi, H; Rennó, N; Rodriguez-Manfredi, J A; Schmidt, W; Richardson, M; Siili, T; Paton, M; Torre-Juarez, M De La; Mäkinen, T; Newman, C; Rafkin, S; Mischna, M; Merikallio, S; Haukka, H; Martin-Torres, J; Komu, M; Zorzano, M-P; Peinado, V; Vazquez, L; Urqui, R
2014-09-01
The Mars Science Laboratory (MSL) made a successful landing at Gale crater early August 2012. MSL has an environmental instrument package called the Rover Environmental Monitoring Station (REMS) as a part of its scientific payload. REMS comprises instrumentation for the observation of atmospheric pressure, temperature of the air, ground temperature, wind speed and direction, relative humidity (REMS-H), and UV measurements. We concentrate on describing the REMS-H measurement performance and initial observations during the first 100 MSL sols as well as constraining the REMS-H results by comparing them with earlier observations and modeling results. The REMS-H device is based on polymeric capacitive humidity sensors developed by Vaisala Inc., and it makes use of transducer electronics section placed in the vicinity of the three humidity sensor heads. The humidity device is mounted on the REMS boom providing ventilation with the ambient atmosphere through a filter protecting the device from airborne dust. The final relative humidity results appear to be convincing and are aligned with earlier indirect observations of the total atmospheric precipitable water content. The water mixing ratio in the atmospheric surface layer appears to vary between 30 and 75 ppm. When assuming uniform mixing, the precipitable water content of the atmosphere is ranging from a few to six precipitable micrometers. Atmospheric water mixing ratio at Gale crater varies from 30 to 140 ppmMSL relative humidity observation provides good dataHighest detected relative humidity reading during first MSL 100 sols is RH75.
Burt, Stephen
2016-09-28
A wide range of surface and near-surface meteorological observations were made at the University of Reading's Atmospheric Observatory in central southern England (latitude 51.441° N, longitude 0.938° W, altitude 66 m above mean sea level) during the deep partial eclipse on the morning of 20 March 2015. Observations of temperature, humidity, radiation, wind speed and direction, and atmospheric pressure were made by computerized logging equipment at 1 Hz, supplemented by an automated cloud base recorder sampling at 1 min intervals and a high-resolution (approx. 10 m vertical interval) atmospheric sounding by radiosonde launched from the same location during the eclipse. Sources and details of each instrumental measurement are described briefly, followed by a summary of observed and derived measurements by meteorological parameter. Atmospheric boundary layer responses to the solar eclipse were muted owing to the heavily overcast conditions which prevailed at the observing location, but instrumental records of the event documented a large (approx. 80%) reduction in global solar radiation, a fall in air temperature of around 0.6°C, a decrease in cloud base height, and a slight increase in atmospheric stability during the eclipse. Changes in surface atmospheric moisture content and barometric pressure were largely insignificant during the event.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'. © 2016 The Author(s).
Mars Science Laboratory relative humidity observations: Initial results
Harri, A-M; Genzer, M; Kemppinen, O; Gomez-Elvira, J; Haberle, R; Polkko, J; Savijärvi, H; Rennó, N; Rodriguez-Manfredi, JA; Schmidt, W; Richardson, M; Siili, T; Paton, M; Torre-Juarez, M De La; Mäkinen, T; Newman, C; Rafkin, S; Mischna, M; Merikallio, S; Haukka, H; Martin-Torres, J; Komu, M; Zorzano, M-P; Peinado, V; Vazquez, L; Urqui, R
2014-01-01
The Mars Science Laboratory (MSL) made a successful landing at Gale crater early August 2012. MSL has an environmental instrument package called the Rover Environmental Monitoring Station (REMS) as a part of its scientific payload. REMS comprises instrumentation for the observation of atmospheric pressure, temperature of the air, ground temperature, wind speed and direction, relative humidity (REMS-H), and UV measurements. We concentrate on describing the REMS-H measurement performance and initial observations during the first 100 MSL sols as well as constraining the REMS-H results by comparing them with earlier observations and modeling results. The REMS-H device is based on polymeric capacitive humidity sensors developed by Vaisala Inc., and it makes use of transducer electronics section placed in the vicinity of the three humidity sensor heads. The humidity device is mounted on the REMS boom providing ventilation with the ambient atmosphere through a filter protecting the device from airborne dust. The final relative humidity results appear to be convincing and are aligned with earlier indirect observations of the total atmospheric precipitable water content. The water mixing ratio in the atmospheric surface layer appears to vary between 30 and 75 ppm. When assuming uniform mixing, the precipitable water content of the atmosphere is ranging from a few to six precipitable micrometers. Key Points Atmospheric water mixing ratio at Gale crater varies from 30 to 140 ppm MSL relative humidity observation provides good data Highest detected relative humidity reading during first MSL 100 sols is RH75% PMID:26213667
Lee, Jaime B; Sohlberg, McKay Moore; Harn, Beth; Horner, Robert; Cherney, Leora R
2018-06-04
People with aphasia frequently present with nonlinguistic deficits, in addition to their compromised language abilities, which may contribute to their problems with reading comprehension. Treatment of attention, working memory and executive control may improve reading comprehension in individuals with aphasia, particularly those with mild reading problems. This single-case experimental design study evaluated the efficacy of Attention Process Training-3, an intervention combining direct attention training and metacognitive facilitation, for improving reading comprehension in individuals with mild aphasia. A multiple baseline design across six participants was used to evaluate treatment effects. The primary outcome measure was a maze reading task. Cognitive measures were administered pre- and post-treatment. Visual inspection of graphed maze reading performance data indicated a basic effect between APT-3 and improved maze reading for three of the six participants. Quantitative analyses, using Tau-U, corroborated findings identified through visual analysis. The overall effect size was significant (Tau = .48, p = .01). Results suggest that APT-3 has the potential to improve reading in individuals with aphasia, but that it may be more efficacious under certain conditions. Treatment and participant variables, including intensity of treatment and metacognitive strategy usage, are discussed as potential influences on participants' responsiveness to APT-3.
Comparison of OH Reactivity Instruments in the Atmosphere Simulation Chamber SAPHIR.
NASA Astrophysics Data System (ADS)
Fuchs, H.; Novelli, A.; Rolletter, M.; Hofzumahaus, A.; Pfannerstill, E.; Edtbauer, A.; Kessel, S.; Williams, J.; Michoud, V.; Dusanter, S.; Locoge, N.; Zannoni, N.; Gros, V.; Truong, F.; Sarda Esteve, R.; Cryer, D. R.; Brumby, C.; Whalley, L.; Stone, D. J.; Seakins, P. W.; Heard, D. E.; Schoemaecker, C.; Blocquet, M.; Fittschen, C. M.; Thames, A. B.; Coudert, S.; Brune, W. H.; Batut, S.; Tatum Ernest, C.; Harder, H.; Elste, T.; Bohn, B.; Hohaus, T.; Holland, F.; Muller, J. B. A.; Li, X.; Rohrer, F.; Kubistin, D.; Kiendler-Scharr, A.; Tillmann, R.; Andres, S.; Wegener, R.; Yu, Z.; Zou, Q.; Wahner, A.
2017-12-01
Two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016 to compare hydroxyl (OH) radical reactivity (kOH) measurements. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapor, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements is higher for instruments directly detecting hydroxyl radicals (OH), whereas the indirect Comparative Reactivity Method (CRM) has a higher limit of detection of 2s-1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapor or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected in the chamber to simulate urban and forested environments. Overall, the results show that instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to the reference were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds. In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied in order to account for known effects of, for example, deviations from pseudo-first order conditions, nitrogen oxides or water vapor on the measurement. Methods to derive these corrections vary among the different CRM instruments. Measurements by a flow-tube instrument combined with the direct detection of OH by chemical ionization mass spectrometry (CIMS) show limitations, but were accurate for low reactivity (< 15s -1) and low NO (< 5 ppbv) conditions.
Rubia-Rubia, J; Arias, A; Sierra, A; Aguirre-Jaime, A
2011-07-01
We compared a range of alternative devices with core body temperature measured at the pulmonary artery to identify the most valid and reliable instrument for measuring temperature in routine conditions in health services. 201 patients from the intensive care unit of the Candelaria University Hospital, Canary Islands, admitted to hospital between April 2006 and July 2007. All patients (or their families) gave informed consent. Readings from gallium-in-glass, reactive strip and digital in axilla, infra-red ear and frontal thermometers were compared with the pulmonary artery core temperature simultaneously. External factors suspected of having an influence on the differences were explored. The cut-off point readings for each thermometer were fixed for the maximum negative predictive value in comparison with the core temperature. The validity, reliability, accuracy, external influence, the waste they generated, ease of use, speed, durability, security, comfort and cost of each thermometer was evaluated. An ad hoc overall valuation score was obtained from these parameters for each instrument. For an error of ± 0.2°C and concordance with respect to fever, the gallium-in-glass thermometer gave the best results. The largest area under the receiver operating characteristic (ROC) curve is obtained by the digital axillar thermometer with probe (0.988 ± 0.007). The minimum difference between readings was given by the infrared ear thermometer, in comparison with the core temperature (-0.1 ± 0.3°C). Age, weight, level of conscience, male sex, environmental temperature and vaso-constrictor medication increases the difference in the readings and fever treatment reduces it, although this is not the same for all thermometers. The compact digital axillar thermometer and the digital thermometer with probe obtained the highest overall valuation score. If we only evaluate the aspects of validity, reliability, accuracy and external influence, the best thermometer would be the gallium-in-glass after 12 min. The gallium-in-glass thermometer is less accurate after only 5 min in comparison with the reading taken after being placed for 12 min. If we add the evaluation of waste production, ease-of-use, speed, durability, security, patient comfort and costs, the thermometers that obtain the highest score are the compact digital and digital with probe in right axilla. Copyright © 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Faverzani, M.; HOLMES Collaboration
2017-09-01
The experiment HOLMES, founded by the European Research Council, will perform a calorimetric measurement of the energy released in the electron capture of 163Ho to directly measure the neutrino mass with a sensitivity of ˜ 1 eV. This approach allows to eliminate the problematics connected to the use of external sources and the systematic uncertainties arising from decays on excited states. Such measurement will be performed with low temperature thermal detectors, where the decay energy is converted into a temperature signal measured by sensitive thermometers. HOLMES, besides of being an important step forward in the direct neutrino mass measurement with a calorimetric approach, will also establish the potential of this approach to extend the sensitivity down to 0.1 eV and lower. The best configuration has been defined with Monte Carlo simulations: HOLMES will collect about 3 × 1013 decays with 1000 detectors characterized by an instrumental energy resolution of the order of the eV and a time resolution of few microseconds. For a measuring time of 3 years, this translates in a total required 163Ho activity of about 300 kBq, equivalent to about 6.5 × 1016 163Ho nuclei, or 18 µg. The HOLMES detectors will have 163Ho implanted into Gold absorber coupled to Transition Edge Sensors, which will be read using microwave multiplexed rf-SQUIDs in combination with a ROACH2 based acquisition system. An extensive R&D activity is in progress in order to maximize the multiplexing factor while preserving the performances of the individual detectors. R&D activities aimed at optimizing the single detector performances, the 163Ho isotope production and embedding are in progress and will converge in a preliminary measurement of an array of 16 detectors planned by the end of 2016. We outline here the HOLMES project with its technical challenges, its status and perspectives.
Kopiez, Reinhard; Galley, Niels; Lee, Ji In
2006-01-01
In this study, the unrehearsed performance of music, known as 'sight reading', is used as a model to examine the influence of motoric laterality on highly challenging musical performance skills. As expertise research has shown, differences in this skill can be partially explained by factors such as accumulated practise and an early start to training. However, up until now, neurobiological factors that may influence highly demanding instrumental performance have been widely neglected. In an experiment with 52 piano students at a German university music department, we could show that the most challenging musical skill, sight reading (which is characterized by extreme demands on the performer's real time information processing), is positively correlated with decreasing right-hand superiority of performers. Laterality was measured by the differences between left and right-hand performance in a speed tapping task. SR achievement was measured using an accompanying task paradigm. An overall superiority of 22% for non-right-handed pianists was found. This effect is gender-related and stronger in non-right-handed males (r(24) = -0.49, p<0.05) than in non-right-handed females (r(28) = -0.16, p>0.05). We conclude that non-right-handed motoric laterality is associated with neurobiological advantages required for sight reading, an extremely demanding musical subskill.
Cheng, Su-Fen; Kuo, Chien-Lin; Lin, Kuan-Chia; Lee-Hsieh, Jane
2010-09-01
With the growing trend of preparing students for lifelong learning, the theory of self-directed learning (SDL) has been increasingly applied in the context of higher education. In order to foster lifelong learning, abilities among nursing students, faculties need to have an appropriate instrument to measure the SDL abilities of nursing students. The objectives of this study were to develop an instrument to measure the SDL abilities of nursing students and to test the validity and reliability of this instrument. This study was conducted in 4 phases. In Phase 1, based on a review of the literature, the researchers developed an instrument to measure SDL. In Phase 2, two rounds of the Delphi study were conducted, to determine the content validity of the instrument. In Phase 3, a convenience sample of 1072 nursing students from two representative schools across three different types of nursing programs were recruited to test the construct validity of the Self-Directed Learning Instrument (SDLI). Finally, in Phase 4, the internal consistency and reliability of the instrument were tested. The resulting SDLI consists of 20 items across the following four domains: learning motivation, planning and implementing, self-monitoring, and interpersonal, communication. The final model in confirmatory factor analysis revealed that this 20-item SDLI indicated a good fit of the model. The value of Cronbach's alpha for the total scale was .916 and for the four domains were .801, .861, .785, and .765, respectively. The SDLI is a valid and reliable instrument for identifying student SDL abilities. It is available to students in nursing and similar medical programs to evaluate their own SDL. This scale may also enable nursing faculty to assess students' SDL status, design better lesson plans and curricula, and, implement appropriate teaching strategies for nursing students in order to foster the growth of lifelong learning abilities. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Chow, Clara K.; Lock, Karen; Madhavan, Manisha; Corsi, Daniel J.; Gilmore, Anna B.; Subramanian, S. V.; Li, Wei; Swaminathan, Sumathi; Lopez-Jaramillo, Patricio; Avezum, Alvaro; Lear, Scott A.; Dagenais, Gilles; Teo, Koon; McKee, Martin; Yusuf, Salim
2010-01-01
Background The environment in which people live is known to be important in influencing diet, physical activity, smoking, psychosocial and other risk factors for cardiovascular (CV) disease. However no instrument exists that evaluates communities for these multiple environmental factors and is suitable for use across different communities, regions and countries. This report describes the design and reliability of an instrument to measure environmental determinants of CV risk factors. Method/Principal Findings The Environmental Profile of Community Health (EPOCH) instrument comprises two parts: (I) an assessment of the physical environment, and (II) an interviewer-administered questionnaire to collect residents' perceptions of their community. We examined the inter-rater reliability amongst 3 observers from each region of the direct observation component of the instrument (EPOCH I) in 93 rural and urban communities in 5 countries (Canada, Colombia, Brazil, China and India). Data collection using the EPOCH instrument was feasible in all communities. Reliability of the instrument was excellent (Intraclass Correlation Coefficient - ICC>0.75) for 24 of 38 items and fair to good (ICC 0.4–0.75) for 14 of 38 items. Conclusion This report shows data collection with the EPOCH instrument is feasible and direct observation of community measures reliable. The EPOCH instrument will enable further research on environmental determinants of health for population studies from a broad range of settings. PMID:21170320
Readability analysis of online resources related to lung cancer.
Weiss, Kathleen D; Vargas, Christina R; Ho, Olivia A; Chuang, Danielle J; Weiss, Jonathan; Lee, Bernard T
2016-11-01
Patients seeking health information commonly use the Internet as the first source for material. Studies show that well-informed patients have increased involvement, satisfaction, and healthcare outcomes. As one-third of Americans have only basic or below basic health literacy, the National Institutes of Health and American Medical Association recommend patient-directed health resources be written at a sixth-grade reading level. This study evaluates the readability of commonly accessed online resources on lung cancer. A search for "lung cancer" was performed using Google and Bing, and the top 10 websites were identified. Location services were disabled, and sponsored sites were excluded. Relevant articles (n = 109) with patient-directed content available directly from the main sites were downloaded. Readability was assessed using 10 established methods and analyzed with articles grouped by parent website. The average reading grade level across all sites was 11.2, with a range from 8.8 (New Fog Count) to 12.2 (Simple Measure of Gobbledygook). The average Flesch Reading Ease score was 52, corresponding with fairly difficult to read text. The readability varied when compared by individual website, ranging in grade level from 9.2 to 15.2. Only 10 articles (9%) were written below a sixth-grade level and these tended to discuss simpler topics. Patient-directed online information about lung cancer exceeds the recommended sixth-grade reading level. Readability varies between individual websites, allowing physicians to direct patients according to level of health literacy. Modifications to existing materials can significantly improve readability while maintaining content for patients with low health literacy. Copyright © 2016 Elsevier Inc. All rights reserved.
Keeping it simple: the grammatical properties of shared book reading.
Noble, Claire H; Cameron-Faulkner, Thea; Lieven, Elena
2018-05-01
The positive effects of shared book reading on vocabulary and reading development are well attested (e.g., Bus, van Ijzendoorn, & Pellegrini, 1995). However, the role of shared book reading in grammatical development remains unclear. In this study, we conducted a construction-based analysis of caregivers' child-directed speech during shared book reading and toy play and compared the grammatical profile of the child-directed speech generated during the two activities. The findings indicate that (a) the child-directed speech generated by shared book reading contains significantly more grammatically rich constructions than child-directed speech generated by toy play, and (b) the grammatical profile of the book itself affects the grammatical profile of the child-directed speech generated by shared book reading.
NASA Astrophysics Data System (ADS)
Schwartz, Richard A.; Zarro, D.; Csillaghy, A.; Dennis, B.; Tolbert, A. K.; Etesi, L.
2009-05-01
We report on our activities to integrate VSO search and retrieval capabilities into standard data access, display, and analysis tools. In addition to its standard Web-based search form, the VSO provides an Interactive Data Language (IDL) client (vso_search) that is available through the Solar Software (SSW) package. We have incorporated this client into an IDL-widget interface program (show_synop) that allows for more simplified searching and downloading of VSO datasets directly into a user's IDL data analysis environment. In particular, we have provided the capability to read VSO datasets into a general purpose IDL package (plotman) that can display different datatypes (lightcurves, images, and spectra) and perform basic data operations such as zooming, image overlays, solar rotation, etc. Currently, the show_synop tool supports access to ground-based and space-based (SOHO, STEREO, and Hinode) observations, and has the capability to include new datasets as they become available. A user encounters two major hurdles when using the VSO: (1) Instrument-specific software (such as level-0 file readers and data-prepping procedures) may not be available in the user's local SSW distribution. (2) Recent calibration files (such as flat-fields) are not automatically distributed with the analysis software. To address these issues, we have developed a dedicated server (prepserver) that incorporates all the latest instrument-specific software libraries and calibration files. The prepserver uses an IDL-Java bridge to read and implement data processing requests from a client and return a processed data file that can be readily displayed with the show_synop/plotman package. The advantage of the prepserver is that the user is only required to install the general branch (gen) of the SSW tree, and is freed from the more onerous task of installing instrument-specific libraries and calibration files. We will demonstrate how the prepserver can be used to read, process, and overlay SOHO/EIT, TRACE, SECCHI/EUVI, and RHESSI images.
Design and Development of "The Reading Biographer": An Application of Function Specific Assessment.
ERIC Educational Resources Information Center
Hanson, Ralph A.; Siegel, Donna Farrell
The general features of function-specific assessment are described and illustrated via a discussion of the design and development of "The Reading Biographer," an instrument for assessing experiences and activities of students (from early childhood through high school) that affect their reading achievement as high school seniors. The…
ERIC Educational Resources Information Center
Wang, Jing-Ru; Wang, Yuh-Chao; Tai, Hsin-Jung; Chen, Wen-Ju
2010-01-01
This study examined the differential impacts of an inquiry-based instruction on conceptual changes across levels of prior knowledge and reading ability. The instrument emphasized four simultaneously important components: conceptual knowledge, reading ability, attitude toward science, and learning environment. Although the learning patterns and…
An Analysis of the Associations between Ambiguity Tolerance and EFL Reading Strategy Awareness
ERIC Educational Resources Information Center
Kamran, Saeedeh Karbalaee; Maftoon, Parviz
2012-01-01
The current study is an attempt to investigate whether any statistically significant relationship existed between Iranian EFL learners' ambiguity tolerance (AT) and their reading strategy use. To this end, three instruments of Survey of Reading Strategy (Mokhtari & Sheorey, 2002), Second Language Ambiguity Tolerance Scale (Ely, 1995), and a…
ERIC Educational Resources Information Center
Palilonis, Jennifer; Butler, Darrell
2015-01-01
The increasing adoption of mobile platforms and digital textbooks in university classrooms continues to have a profound impact on higher education. Advocates believe that providing students digital textbooks with built-in annotation features and interactive study tools will improve learning by facilitating active reading, a task essential to…
VISION AND COLLEGE READING - A REVIEW OF THE LITERATURE AND REPORT OF A SURVEY.
ERIC Educational Resources Information Center
MAXWELL, MARTHA J.
THE AMERICAN OPTICAL (AO) COMPANY'S SIGHT SCREENER, A PORTABLE BINOCULAR INSTRUMENT DESIGNED FOR MASS VISION TESTING, WAS EVALUATED AT THE UNIVERSITY OF MARYLAND READING AND STUDY SKILLS LABORATORY TO DETERMINE ITS CAPACITY TO IDENTIFY STUDENTS NEEDING PROFESSIONAL EYE EXAMINATIONS PRIOR TO READING INSTRUCTION. DATA FROM 106 PROBATIONARY FRESHMEN,…
AAMD-Becker Reading-Free Vocational Interest Inventory Manual [and Male and Female Inventories].
ERIC Educational Resources Information Center
Becker, Ralph L.
The AAMD-Becker Reading-Free Vocational Interest Inventory is a non-reading vocational preference test for use with mentally retarded persons, particularly the educable mentally retarded at the high school level. Illustrations having occupational significance are presented in forced-choice format for selections. The instrument helps to identify…
ERIC Educational Resources Information Center
Klesius, Janell P.; Homan, Susan P.
1985-01-01
The article reviews validity and reliability studies on the informal reading inventory, a diagnostic instrument to identify reading grade-level placement and strengths and weaknesses in work recognition and comprehension. Gives suggestions to improve the validity and reliability of existing inventories and to evaluate them in newly published…
Interplay Between Reading Tasks, Reader Variables, and Unknown Word Processing.
ERIC Educational Resources Information Center
Levine, Adina; Reves, Thea
1998-01-01
Examined to what extent readers' word-treatment strategies are task dependent, and to what extent word-treatment strategies are dependent on the reader's reading profile. Subjects were 42 students of English for academic purposes advanced reading-comprehension course. Instruments used in the study included a word-treatment experiment, an open…
Nanopore sequencing in microgravity
McIntyre, Alexa B R; Rizzardi, Lindsay; Yu, Angela M; Alexander, Noah; Rosen, Gail L; Botkin, Douglas J; Stahl, Sarah E; John, Kristen K; Castro-Wallace, Sarah L; McGrath, Ken; Burton, Aaron S; Feinberg, Andrew P; Mason, Christopher E
2016-01-01
Rapid DNA sequencing and analysis has been a long-sought goal in remote research and point-of-care medicine. In microgravity, DNA sequencing can facilitate novel astrobiological research and close monitoring of crew health, but spaceflight places stringent restrictions on the mass and volume of instruments, crew operation time, and instrument functionality. The recent emergence of portable, nanopore-based tools with streamlined sample preparation protocols finally enables DNA sequencing on missions in microgravity. As a first step toward sequencing in space and aboard the International Space Station (ISS), we tested the Oxford Nanopore Technologies MinION during a parabolic flight to understand the effects of variable gravity on the instrument and data. In a successful proof-of-principle experiment, we found that the instrument generated DNA reads over the course of the flight, including the first ever sequenced in microgravity, and additional reads measured after the flight concluded its parabolas. Here we detail modifications to the sample-loading procedures to facilitate nanopore sequencing aboard the ISS and in other microgravity environments. We also evaluate existing analysis methods and outline two new approaches, the first based on a wave-fingerprint method and the second on entropy signal mapping. Computationally light analysis methods offer the potential for in situ species identification, but are limited by the error profiles (stays, skips, and mismatches) of older nanopore data. Higher accuracies attainable with modified sample processing methods and the latest version of flow cells will further enable the use of nanopore sequencers for diagnostics and research in space. PMID:28725742
REMS Wind Sensor Preliminary Results
NASA Astrophysics Data System (ADS)
De La Torre Juarez, M.; Gomez-Elvira, J.; Navarro, S.; Marin, M.; Torres, J.; Rafkin, S. C.; Newman, C. E.; Pla-García, J.
2015-12-01
The REMS instrument is part of the Mars Science Laboratory payload. It is a sensor suite distributed over several parts of the rover. The wind sensor, which is composed of two booms equipped with a set of hot plate anemometers, is installed on the Rover Sensing Mast (RSM). During landing most of the hot plates of one boom were damaged, most likely by the pebbles lifted by the Sky Crane thruster. The loss of one wind boom necessitated a full review of the data processing strategy. Different algorithms have been tested on the readings of the first Mars year, and these results are now archived in the Planetary Data System (PDS), The presentation will include a description of the data processing methods and of the resulting products, including the typical evolution of wind speed and direction session-by-session, hour-by-hour and other kinds of statistics . A review of the wind readings over the first Mars year will also be presented.
Qi, Chaolong; Echt, Alan; Murata, Taichi K
2016-06-01
We conducted a laboratory test to characterize dust from cutting Corian(®), a solid-surface composite material, with a circular saw. Air samples were collected using filters and direct-reading instruments in an automatic laboratory testing system. The average mass concentrations of the total and respirable dusts from the filter samples were 4.78±0.01 and 1.52±0.01mg cm(-3), respectively, suggesting about 31.8% mass of the airborne dust from cutting Corian(®) is respirable. Analysis of the metal elements on the filter samples reveals that aluminum hydroxide is likely the dominant component of the airborne dust from cutting Corian(®), with the total airborne and respirable dusts containing 86.0±6.6 and 82.2±4.1% aluminum hydroxide, respectively. The results from the direct-reading instruments confirm that the airborne dust generated from cutting Corian(®) were mainly from the cutting process with very few particles released from the running circular saw alone. The number-based size distribution of the dusts from cutting Corian(®) had a peak for fine particles at 1.05 µm with an average total concentration of 871.9 particles cm(-3), and another peak for ultrafine particles at 11.8nm with an average total concentration of 1.19×10(6) particles cm(-3) The small size and high concentration of the ultrafine particles suggest additional investigation is needed to study their chemical composition and possible contribution to pulmonary effect. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.
Qi, Chaolong; Echt, Alan; Murata, Taichi K
2016-01-01
We conducted a laboratory test to characterize dust from cutting Corian®, a solid-surface composite material, with a circular saw. Air samples were collected using filters and direct-reading instruments in an automatic laboratory testing system. The average mass concentrations of the total and respirable dusts from the filter samples were 4.78±0.01 and 1.52±0.01 mg cm−3, respectively, suggesting about 31.8% mass of the airborne dust from cutting Corian® is respirable. Analysis of the metal elements on the filter samples reveals that aluminum hydroxide is likely the dominant component of the airborne dust from cutting Corian®, with the total airborne and respirable dusts containing 86.0%±6.6% and 82.2%±4.1% aluminum hydroxide, respectively. The results from the direct-reading instruments confirm that the airborne dust generated from cutting Corian® were mainly from the cutting process with very few particles released from the running circular saw alone. The number-based size distribution of the dusts from cutting Corian® had a peak for fine particles at 1.05 µm with an average total concentration of 871.9 particles cm−3, and another peak for ultrafine particles at 11.8 nm with an average total concentration of 1.19×106 particles cm−3. The small size and high concentration of the ultrafine particles suggest additional investigation is needed to study their chemical composition and possible contribution to pulmonary effect. PMID:26872962
Jones, K P; Mullee, M A
1990-01-01
OBJECTIVE--To compare measurements of the peak expiratory flow rate taken by the mini Wright peak flow meter and the turbine spirometer. DESIGN--Pragmatic study with randomised order of use of recording instruments. Phase 1 compared a peak expiratory flow type expiration recorded by the mini Wright peak flow meter with an expiration to forced vital capacity recorded by the turbine spirometer. Phase 2 compared peak expiratory flow type expirations recorded by both meters. Reproducibility was assessed separately. SETTING--Routine surgeries at Aldermoor Health Centre, Southampton. SUBJECTS--212 Patients aged 4 to 78 presenting with asthma or obstructive airways disease. Each patient contributed only once to each phase (105 in phase 1, 107 in phase 2), but some entered both phases on separate occasions. Reproducibility was tested on a further 31 patients. MAIN OUTCOME MEASURE--95% Limits of agreement between measurements on the two meters. RESULTS--208 (98%) Of the readings taken by the mini Wright meter were higher than the corresponding readings taken by the turbine spirometer, but the 95% limits of agreement (mean difference (2 SD] were wide (1 to 173 l/min). Differences due to errors in reproducibility were not sufficient to predict this level of disagreement. Analysis by age, sex, order of use, and the type of expiration did not detect any significant differences. CONCLUSIONS--The two methods of measuring peak expiratory flow rate were not comparable. The mini Wright meter is likely to remain the preferred instrument in general practice. PMID:2142611
40 CFR 98.314 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... accounting purposes including direct measurement weighing the petroleum coke fed into your process (by belt... line dioxide using plant instruments used for accounting purposes including direct measurement weighing... used to ensure the accuracy of monthly calcined petroleum coke consumption measurements. (c) You must...
El Zein, Farah; Solis, Michael; Lang, Russell; Kim, Min Kyung
2016-06-01
We investigated the effects of embedding the perseverative interest (PI) of a child with autism (i.e. cars) within texts on reading comprehension. A PI text condition (text altered to include cars) was compared with a non-PI text condition (same story without cars inserted) in an alternating treatment design. Dependent variables were responses to reading comprehension questions and number of words uttered during an oral retell (i.e. curriculum-based measures [CBMs]). The reading level, instructional routines, and therapist where held constant across the randomly alternated conditions. Both CBMs suggested that reading comprehension was enhanced when the story included the child's PI. These preliminary findings suggest that embedding the PIs of students with autism spectrum disorder within readings may result in more accurate responses to reading comprehension questions and more detailed oral retelling. These findings are discussed in terms of potential directions for future research.
The dynamic effect of reading direction habit on spatial asymmetry of image perception.
Afsari, Zaeinab; Ossandón, José P; König, Peter
2016-09-01
Exploration of images after stimulus onset is initially biased to the left. Here, we studied the causes of such an asymmetry and investigated effects of reading habits, text primes, and priming by systematically biased eye movements on this spatial bias in visual exploration. Bilinguals first read text primes with right-to-left (RTL) or left-to-right (LTR) reading directions and subsequently explored natural images. In Experiment 1, native RTL speakers showed a leftward free-viewing shift after reading LTR primes but a weaker rightward bias after reading RTL primes. This demonstrates that reading direction dynamically influences the spatial bias. However, native LTR speakers who learned an RTL language late in life showed a leftward bias after reading either LTR or RTL primes, which suggests the role of habit formation in the production of the spatial bias. In Experiment 2, LTR bilinguals showed a slightly enhanced leftward bias after reading LTR text primes in their second language. This might contribute to the differences of native RTL and LTR speakers observed in Experiment 1. In Experiment 3, LTR bilinguals read normal (LTR, habitual reading) and mirrored left-to-right (mLTR, nonhabitual reading) texts. We observed a strong leftward bias in both cases, indicating that the bias direction is influenced by habitual reading direction and is not secondary to the actual reading direction. This is confirmed in Experiment 4, in which LTR participants were asked to follow RTL and LTR moving dots in prior image presentation and showed no change in the normal spatial bias. In conclusion, the horizontal bias is a dynamic property and is modulated by habitual reading direction.
Direct reading inductance meter
NASA Technical Reports Server (NTRS)
Kolby, R. B. (Inventor)
1977-01-01
A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.
Ouellette, Gene; Sénéchal, Monique
2017-01-01
In this study we evaluated whether the sophistication of children's invented spellings in kindergarten was predictive of subsequent reading and spelling in Grade 1, while also considering the influence of well-known precursors. Children in their first year of schooling (mean age = 66 months; N = 171) were assessed on measures of oral vocabulary, alphabetic knowledge, phonological awareness, word reading and invented spelling; approximately 1 year later they were assessed on multiple measures of reading and spelling. Path modeling was pursued to evaluate a hypothesized unique, causal role of invented spelling in subsequent literacy outcomes. Results supported a model in which invented spelling contributed directly to concurrent reading along with alphabetic knowledge and phonological awareness. Longitudinally, invented spelling influenced subsequent reading, along with alphabetic knowledge while mediating the connection between phonological awareness and early reading. Invented spelling also influenced subsequent conventional spelling along with phonological awareness, while mediating the influence of alphabetic knowledge. Invented spelling thus adds explanatory variance to literacy outcomes not entirely captured by well-studied code and language-related skills. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Unlocking Short Read Sequencing for Metagenomics
Rodrigue, Sébastien; Materna, Arne C.; Timberlake, Sonia C.; ...
2010-07-28
We describe an experimental and computational pipeline yielding millions of reads that can exceed 200 bp with quality scores approaching that of traditional Sanger sequencing. The method combines an automatable gel-less library construction step with paired-end sequencing on a short-read instrument. With appropriately sized library inserts, mate-pair sequences can overlap, and we describe the SHERA software package that joins them to form a longer composite read.
Effect of Direct Glare on Orbicularis Oculi and Trapezius During Computer Reading.
Mork, Randi; Bruenech, Jan Richard; Thorud, Hanne Mari Schiøtz
2016-07-01
Unfavorable visual conditions during computer work may affect development of both eyestrain and musculoskeletal pain in the neck and shoulder area. The aim of the study was to investigate how direct glare affects symptom development, muscle activity, and muscle blood flow in m. orbicularis oculi and m. trapezius during reading on a computer screen. Fifteen healthy young adults with normal binocular vision read text on a computer screen at an optimized computer workplace, 30 minutes with glare exposure and 30 minutes with appropriate lighting. Postural angles were continuously registered. Development of eye symptoms and musculoskeletal pain in the neck and shoulder area were recorded using VAS scales. Muscle activity and muscle blood flow were measured continuously using electromyography and photoplethysmography, respectively. Glare exposure resulted in significantly more pronounced eye pain, increased orbicularis muscle activity, and increased trapezius blood flow compared to reading with appropriate lighting. There were no significant differences in posture between the two light conditions. There were also significant associations between orbicularis oculi activity and both trapezius blood flow and neck pain during both conditions. Results from the current study show that direct glare conditions cause increased eyestrain and orbicularis oculi contraction during reading on a computer screen. This study also indicates that exposure to direct glare affects the trapezius muscle, possibly by an interaction between the visual system, sympathetic nervous system, and head-stabilizing muscles. In addition, there were associations between the use of orbicularis oculi, trapezius blood flow, and development of neck pain independent of the lighting.
The GCR All-Particle Spectrum in the 0.1-100 TeV Energy Range
NASA Astrophysics Data System (ADS)
Tolstaya, Ekaterina D.; Grigorov, N. L.
2003-07-01
The results of direct measurements of the all particle spectra by five different instruments on satellites and balloons are considered. It is shown, that is the representatio as the flux multiplied by energy to the power of 2.6 the all-particle spectrum shows a 'step'. The parameters of this 'step' and its origin are analyzed. Historically it has so happ ened that the all-particle spectrum obtained as the sum individual components, the energy range 1 < E < (5 - 10) TeV in the proton spectrum is not covered by direct measurements. Usually this energy interval in the all-particle spectrum is filled via interp olation, which is bases on the assumption that the proton spectrum is similar to the spectrum of nuclei. This spectrum is usually considered to be the all-particle GCR spectrum Io (E ) [1]. Direct information on the all-particle spectrum in the energy range from 1 to 10 TeV can be obtained using direct measurements of the of the all-particle spectrum by electronic instruments. For the first time such information was obtained in 1972 as a result of the all-particle spectrum measurements by the SEZ-14 instrument on the 'Proton1,2,3' satellites and the SEZ-15 instrument on the 'Proton-4' satellite [2,3]. These measurements revealed an anomaly in the all-particle spectrum in the 1-10 TeV energy range. In 1997 the spectrum was measured again by the TIC instrument [4]. The TIC instrument measured the energy release of all-particles arriving from arbitrary directions. As it was shown by the authors in [4,5] the energy release spectrum revealed the same anomaly in the all-particle spectrum, previously observed in the measurements made on 'Proton' satellites [2]. The results of the measurements made by the TIC, SEZ-14 and SEZ-15 are shown in Fig.1. The solid line in Fig.1 shows the function Φ(E ), which gives a good approximation of the experimental all-particle spectrum at a =0.4 TeV. Φ(E ) = E 2.6 Io (E ) (E /a)3 0.11 } + 0.130m-2s-1 sr -1 T eV 1.6 (1) {1 + 0.37 = [1 + (E /a)3 ]0.2 1 + (E /a)3 It can be seen from Fig.1 that the anomaly in the all-particle spectrum shows a
Microwave radiometer for subsurface temperature measurement
NASA Technical Reports Server (NTRS)
Porter, R. A.; Bechis, K. P.
1976-01-01
A UHF radiometer, operating at a frequency of 800 MHz, was modified to provide an integral, three frequency voltage standing wave ratio (VSWR) circuit in the radio frequency (RF) head. The VSWR circuit provides readings of power transmission at the antenna-material interface with an accuracy of plus or minus 5 percent. The power transmission readings are numerically equal to the emissivity of the material under observation. Knowledge of material emissivity is useful in the interpretation of subsurface apparent temperatures obtained on phantom models of biological tissue. The emissivities of phantom models consisting of lean beefsteak were found to lie in the range 0.623 to 0.779, depending on moisture content. Radiometric measurements performed on instrumented phantoms showed that the radiometer was capable of sensing small temperature changes occurring at depths of at least 19 to 30 mm. This is consistent with previously generated data which showed that the radiometer could sense temperatures at a depth of 38 mm.
NASA Astrophysics Data System (ADS)
Blankenhorn, M.; Heintze, E.; Slota, M.; van Slageren, J.; Moores, B. A.; Degen, C. L.; Bogani, L.; Dressel, M.
2017-09-01
The design and realization of a torque magnetometer is reported that reads the deflection of a membrane by optical interferometry. The compact instrument allows for low-temperature measurements of tiny crystals less than a microgram with a significant improvement in sensitivity, signal-to-noise ratio as well as data acquisition time compared with conventional magnetometry and offers an enormous potential for further improvements and future applications in different fields. Magnetic measurements on single-molecule magnets demonstrate the applicability of the membrane-based torque magnetometer.
Blankenhorn, M; Heintze, E; Slota, M; van Slageren, J; Moores, B A; Degen, C L; Bogani, L; Dressel, M
2017-09-01
The design and realization of a torque magnetometer is reported that reads the deflection of a membrane by optical interferometry. The compact instrument allows for low-temperature measurements of tiny crystals less than a microgram with a significant improvement in sensitivity, signal-to-noise ratio as well as data acquisition time compared with conventional magnetometry and offers an enormous potential for further improvements and future applications in different fields. Magnetic measurements on single-molecule magnets demonstrate the applicability of the membrane-based torque magnetometer.
Statistical analysis of the calibration procedure for personnel radiation measurement instruments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bush, W.J.; Bengston, S.J.; Kalbeitzer, F.L.
1980-11-01
Thermoluminescent analyzer (TLA) calibration procedures were used to estimate personnel radiation exposure levels at the Idaho National Engineering Laboratory (INEL). A statistical analysis is presented herein based on data collected over a six month period in 1979 on four TLA's located in the Department of Energy (DOE) Radiological and Environmental Sciences Laboratory at the INEL. The data were collected according to the day-to-day procedure in effect at that time. Both gamma and beta radiation models are developed. Observed TLA readings of thermoluminescent dosimeters are correlated with known radiation levels. This correlation is then used to predict unknown radiation doses frommore » future analyzer readings of personnel thermoluminescent dosimeters. The statistical techniques applied in this analysis include weighted linear regression, estimation of systematic and random error variances, prediction interval estimation using Scheffe's theory of calibration, the estimation of the ratio of the means of two normal bivariate distributed random variables and their corresponding confidence limits according to Kendall and Stuart, tests of normality, experimental design, a comparison between instruments, and quality control.« less
Comparison of OH reactivity measurements in the atmospheric simulation chamber SAPHIR
NASA Astrophysics Data System (ADS)
Fuchs, Hendrik; Novelli, Anna; Rolletter, Michael; Hofzumahaus, Andreas; Pfannerstill, Eva Y.; Kessel, Stephan; Edtbauer, Achim; Williams, Jonathan; Michoud, Vincent; Dusanter, Sebastien; Locoge, Nadine; Zannoni, Nora; Gros, Valerie; Truong, Francois; Sarda-Esteve, Roland; Cryer, Danny R.; Brumby, Charlotte A.; Whalley, Lisa K.; Stone, Daniel; Seakins, Paul W.; Heard, Dwayne E.; Schoemaecker, Coralie; Blocquet, Marion; Coudert, Sebastien; Batut, Sebastien; Fittschen, Christa; Thames, Alexander B.; Brune, William H.; Ernest, Cheryl; Harder, Hartwig; Muller, Jennifer B. A.; Elste, Thomas; Kubistin, Dagmar; Andres, Stefanie; Bohn, Birger; Hohaus, Thorsten; Holland, Frank; Li, Xin; Rohrer, Franz; Kiendler-Scharr, Astrid; Tillmann, Ralf; Wegener, Robert; Yu, Zhujun; Zou, Qi; Wahner, Andreas
2017-10-01
Hydroxyl (OH) radical reactivity (kOH) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements (limit of detection < 1 s-1 at a time resolution of 30 s to a few minutes) is higher for instruments directly detecting hydroxyl radicals, whereas the indirect comparative reactivity method (CRM) has a higher limit of detection of 2 s-1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapour or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds (mixing ratio of OH reactants were up to 10 ppbv). In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied to account for known effects of, for example, deviations from pseudo first-order conditions, nitrogen oxides or water vapour on the measurement. Methods used to derive these corrections vary among the different CRM instruments. Measurements taken with a flow-tube instrument combined with the direct detection of OH by chemical ionisation mass spectrometry (CIMS) show limitations in cases of high reactivity and high NO concentrations but were accurate for low reactivity (< 15 s-1) and low NO (< 5 ppbv) conditions.
40 CFR 98.214 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (for Equation U-2 of this subpart) must be determined annually from monthly measurements using the same plant instruments used for accounting purposes including purchase records or direct measurement, such as... accounting purposes including purchase records or direct measurement, such as weigh hoppers or belt weigh...
Laser Range and Bearing Finder with No Moving Parts
NASA Technical Reports Server (NTRS)
Bryan, Thomas C.; Howard, Richard T.; Book, Michael L.
2007-01-01
A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.
Ceccolini, E; Rocchi, F; Mostacci, D; Sumini, M; Tartari, A
2011-08-01
The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar® has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented.
A structurally decoupled mechanism for measuring wrist torque in three degrees of freedom
NASA Astrophysics Data System (ADS)
Pan, Lizhi; Yang, Zhen; Zhang, Dingguo
2015-10-01
The wrist joint is a critical part of the human body for movement. Measuring the torque of the wrist with three degrees of freedom (DOFs) is important in some fields, including rehabilitation, biomechanics, ergonomics, and human-machine interfacing. However, the particular structure of the wrist joint makes it difficult to measure the torque in all three directions simultaneously. This work develops a structurally decoupled instrument for measuring and improving the measurement accuracy of 3-DOF wrist torque during isometric contraction. Three single-axis torque sensors were embedded in a customized mechanical structure. The dimensions and components of the instrument were designed based on requirement of manufacturability. A prototype of the instrument was machined, assembled, integrated, and tested. The results show that the structurally decoupled mechanism is feasible for acquiring wrist torque data in three directions either independently or simultaneously. As a case study, we use the device to measure wrist torques concurrently with electromyography signal acquisition in preparation for simultaneous and proportional myoelectric control of prostheses.
A structurally decoupled mechanism for measuring wrist torque in three degrees of freedom.
Pan, Lizhi; Yang, Zhen; Zhang, Dingguo
2015-10-01
The wrist joint is a critical part of the human body for movement. Measuring the torque of the wrist with three degrees of freedom (DOFs) is important in some fields, including rehabilitation, biomechanics, ergonomics, and human-machine interfacing. However, the particular structure of the wrist joint makes it difficult to measure the torque in all three directions simultaneously. This work develops a structurally decoupled instrument for measuring and improving the measurement accuracy of 3-DOF wrist torque during isometric contraction. Three single-axis torque sensors were embedded in a customized mechanical structure. The dimensions and components of the instrument were designed based on requirement of manufacturability. A prototype of the instrument was machined, assembled, integrated, and tested. The results show that the structurally decoupled mechanism is feasible for acquiring wrist torque data in three directions either independently or simultaneously. As a case study, we use the device to measure wrist torques concurrently with electromyography signal acquisition in preparation for simultaneous and proportional myoelectric control of prostheses.
Attitude Assessment for Research in Economic Education.
ERIC Educational Resources Information Center
Hodgin, Robert F.
Guidelines for the construction and use of an attitude instrument are presented, and the application of the instrument to measure student attitude toward economics is described. Attention is directed to the Likert-like summated forced-choice variety of attitude instrument, whereby attitude toward the object is inferred from the summed responses to…
NASA Astrophysics Data System (ADS)
Borovski, A.; Postylyakov, O.; Elokhov, A.; Bruchkovski, I.
2017-11-01
An instrument for measuring atmospheric trace gases by DOAS method using scattered solar radiation was developed in A.M.Obukhov IAP RAS. The instrument layout is based on the lab Shamrock 303i spectrograph supplemented by 2-port radiation input system employing optical fiber. Optical ports may be used with a telescope with fixed field of view or with a scanning MAX-DOAS unit. MAX-DOAS unit port will be used for investigation of gas contents and profiles in the low troposphere. In September 2016 the IAP instrument participated in the CINDI-2 campaign, held in the Netherlands. CINDI 2 (2nd Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments) involves about 40 instruments quasi-synchronously performing DOAS measurements of NO2 and other trace gases. During the campaign the instrument ports had telescopes A and B with similar field of view of about 0.3°. Telescope A was always directed to the zenith. Telescope B was directed at 5° elevation angle. Two gratings were installed in the spectrometer. They provide different spectral resolution (FWHM 0.4 and 0.8 nm respectively) and spectral window width ( 70 and 140 nm respectively). During CINDI-2 campaign we performed test measurements in UV and visible wavelength ranges to investigate instrument stability and retrieval errors of NO2 and HCHO contents. We perform the preliminary error analysis of retrieval of the NO2 and HCHO differential slant column densities using spectra measured in four modes of the instrument basing on residual noise analysis in this paper. It was found that rotation of grating turret does not significantly affected on quality of NO2 DSCD retrieval from spectra which measured in visible spectral region. Influence of grating turret rotation is much more significant for gas DSCD retrieval from spectra which measured in UV spectral region. Standard deviation of retrieval error points to presence of some systematic error.
Accelerated Reader/Reading Renaissance. What Works Clearinghouse Intervention Report
ERIC Educational Resources Information Center
What Works Clearinghouse, 2007
2007-01-01
The Accelerated Reader/Reading Renaissance program (now called Accelerated Reader Best Classroom Practices) is a guided reading intervention in which teachers direct student reading of text. It involves two components. Reading Renaissance, the first component, is a set of recommended principles on guided reading (or teachers' direction of…
Matsuura, Masato; Hirasawa, Kazunori; Hirasawa, Hiroyo; Yanagisawa, Mieko; Murata, Hiroshi; Mayama, Chihiro; Asaoka, Ryo
2017-02-01
To construct a new item bank to measure quality of life (QOL) in glaucoma patients and to evaluate glaucoma patients' QOL using the item bank. An item bank of questions was generated through a literature review of QOL instruments useful for glaucoma patients. Using this item bank, a cognitive survey was performed on 203 patients with glaucoma (112 males and 91 females, 61.9±11.9 y old; mean±SD). The results were then analyzed using the Rasch analysis, and the Rasch-derived disability scores were predicted using linear modelling and the following clinical parameters: age, mean total deviation (mTD) in superior and inferior visual field (mTDsup/mTDinf), mTD progression rate, better visual acuity, worse visual acuity, number of eye drops administered per day, number of trabeculectomy procedures experienced in both eyes. A total of 23 questionnaires of QOL in glaucoma patients were identified resulting in an item bank of 187 questions related to the following tasks: reading/writing, walking, going out, eating and driving (direct disability) as well as questions concerned with worry/anxiety, social participation, and physical symptoms (indirect disability). In the optimal model for direct disability, age and mTDinf were identified as significant predictors, whereas number of eye drops administered per day and number of trabeculectomy experienced were included in the optimal model for indirect disability. A new item bank to measure QOL in glaucoma patients was developed and evaluated. Age and mTDinf were found to be related to direct disability while medical and surgical treatments were related to indirect disability.
AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers
NASA Technical Reports Server (NTRS)
Gottardi, L.; van de Kuur, J.; Bandler, S.; Bruijn, M.; de Korte, P.; Gao, J. R.; den Hartog, R.; Hijmering, R. A.; Hoevers, H.; Koshropanah, P.;
2011-01-01
SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.
Influence of Eye Movements, Auditory Perception, and Phonemic Awareness in the Reading Process
ERIC Educational Resources Information Center
Megino-Elvira, Laura; Martín-Lobo, Pilar; Vergara-Moragues, Esperanza
2016-01-01
The authors' aim was to analyze the relationship of eye movements, auditory perception, and phonemic awareness with the reading process. The instruments used were the King-Devick Test (saccade eye movements), the PAF test (auditory perception), the PFC (phonemic awareness), the PROLEC-R (lexical process), the Canals reading speed test, and the…
Reading and Readability Affect on E-Learning Success in a Fortune 100 Company: A Correlational Study
ERIC Educational Resources Information Center
Finnegan, Denis Michael Thomas
2010-01-01
The purpose of this quantitative correlational study was to examine the relationship between employees' reading skills, E-learning readability, student learning, and student satisfaction. The Tests of Adult Basic Education (TABE) form 10 Level A instrument evaluated student-reading skills. The Flesch-Kincaid Grade Level Index course assessed…
ERIC Educational Resources Information Center
Borges, Francisca
The relative effectiveness of several testing instruments in predicting the reading achievement of Puerto Rican first graders was investigated in this dissertation. One hundred seventy-four students were tested by the "Reading Readiness Test (Prueba de Apresto)," the "Collective Puerto Rican Test of Mental Capacity (Prueba Colectiva de Capacidad…
An Oral Language Based Reading Remedial Program for Special Education Children.
ERIC Educational Resources Information Center
Langdon, Tom
A problem was addressed within the context of the action based research practicum model. The problem was junior high school special education students who read at or below the 10th percentile when compared to age appropriate peers on standardized achievement instruments; and who have had all manner of reading interventions and yet continue to fall…
ERIC Educational Resources Information Center
Coulter, Gail
2004-01-01
In the present climate of declining resources and increased accountability, partnerships are instrumental in achieving student outcomes. The purpose of this article is to describe an unusual university and district partnership supported through America Reads Challenge and AmeriCorps. The America Reads Challenge was to mobilize an army of reading…
"I Am in Grade One and I Can Read!" The Readers' Workshop
ERIC Educational Resources Information Center
Mounla, Ghina; Bahous, Rima; Nabhani, Mona
2011-01-01
This study analyzed the effects of the implementation of the readers' workshop on students' reading levels and comprehension skills in a first-grade, mixed-ability classroom in Lebanon. The instruments used at the beginning were running records and reading continuums, and at the end of the academic year, teachers' professional notebooks and notes…
Hyperspectral Sun Photometer for Atmospheric Characterization and Vicarious Calibrations
NASA Technical Reports Server (NTRS)
Pagnutti, Mary; Ryan, Robert; Holekamp, Kara
2008-01-01
A hyperspectral sun photometer and associated methods have been developed and demonstrated. Accurate sun photometer calibration is critical to properly measure the solar irradiance and characterize the atmosphere. Traditional sun photometer calibration requires solar observations over several hours. In contrast, the procedures for operating this photometer entail less data acquisition time and embody a more direct approach to calibration. The scientific value of the measurement data produced by this instrument is not adversely affected by atmospheric instability. In addition, this instrument yields hyperspectral data covering a large spectral range (350-2,500 nm) not available from most traditional sun photometers. The hyperspectral sun photometer components include (1) a commercially available spectroradiometer that has been laboratory-calibrated and (2) a commercially available reflectance standard panel that exhibits nearly Lambertian 99% reflectance. The spectroradiometer is positioned above, and aimed downward at, the panel. The procedure for operating this instrument calls for a series of measurements: one in which the panel is fully illuminated by the sun, one in which a shade is positioned between the panel and the sun, and two in which the shade is positioned to cast a shadow to either side of the panel. The total sequence of measurements can be performed in less than a minute. From these measurements, the total radiance, the diffuse radiance, and the direct solar radiance are calculated. The direct solar irradiance is calculated from the direct solar radiance and the known reflectance factor of the panel as a function of the solar zenith angle. Atmospheric characteristics are estimated from the optical depth at various wavelengths calculated from (1) the direct solar irradiance obtained as described above, (2) the air mass along a column from the measurement position to the Sun, and (3) the top-of-atmosphere solar irradiance. The instrumentation used to implement the sun photometer is the same as that used to characterize targets used in radiometric vicarious calibrations. Utilizing this type of sun photometer thus reduces the amount of instrumentation and labor required to perform these studies.
El-Khechen, Wahiba; Ferdinand, Hanna D; Steinmayr, Ricarda; McElvany, Nele
2016-06-01
Although various studies on general language performance have investigated determinants of students' reading comprehension (e.g., reading amount), they have paid insufficient attention to how students perceive parental values influence their language-related values and behaviour - and, as a consequence, their performance. This is particularly the case for bilingual students with a migration background. The present study aims to examine the impact of how students perceive parental values regarding German (attainment, utility, and cost), students' (utility) value of German/Turkish, and students' reading amount in German/Turkish on German reading comprehension. A total of 118 Grade 4 students in Germany with Turkish as their family language. Reading comprehension was measured with a 15-item standardized test. Whereas students' reading amount (German/Turkish) was assessed through students' self-reports on three questions, students' utility value (German/Turkish) and perceived parental values regarding German (attainment, utility, and cost) were each measured with two items. Results of path modelling supported the hypotheses that students' utility value regarding German and their reading amount in German would positively predict their German reading comprehension, whereas their utility value regarding Turkish and their reading amount in Turkish would negatively predict their German reading comprehension. Data also confirmed a direct effect of the negatively perceived parental cost value of German on German reading comprehension. The new evidence is of practical relevance for teachers, educational scientists, and psychologists who are striving to improve the educational outcomes of bilingual students. Further research needs and the significance of the results for educational practice and home environment are discussed. © 2015 The British Psychological Society.
Semi-empirical and phenomenological instrument functions for the scanning tunneling microscope
NASA Astrophysics Data System (ADS)
Feuchtwang, T. E.; Cutler, P. H.; Notea, A.
1988-08-01
Recent progress in the development of a convenient algorithm for the determination of a quantitative local density of states (LDOS) of the sample, from data measured in the STM, is reviewd. It is argued that the sample LDOS strikes a good balance between the information content of a surface characteristic and effort required to obtain it experimentally. Hence, procedures to determine the sample LDOS as directly and as tip-model independently as possible are emphasized. The solution of the STM's "inverse" problem in terms of novel versions of the instrument (or Green) function technique is considered in preference to the well known, more direct solutions. Two types of instrument functions are considered: Approximations of the basic tip-instrument function obtained from the transfer Hamiltonian theory of the STM-STS. And, phenomenological instrument functions devised as a systematic scheme for semi-empirical first order corrections of "ideal" models. The instrument function, in this case, describes the corrections as the response of an independent component of the measuring apparatus inserted between the "ideal" instrument and the measured data. This linear response theory of measurement is reviewed and applied. A procedure for the estimation of the consistency of the model and the systematic errors due to the use of an approximate instrument function is presented. The independence of the instrument function techniques from explicit microscopic models of the tip is noted. The need for semi-empirical, as opposed to strictly empirical or analytical determination of the instrument function is discussed. The extension of the theory to the scanning tunneling spectrometer is noted, as well as its use in a theory of resolution.
[Measurement of Speed and Direction of Ocean Surface Winds Using Quik Scat Scatterometer
NASA Technical Reports Server (NTRS)
Stiles, Bryan; Pollard, Brian
2000-01-01
The SeaWinds on QuikSCAT scatterometer was developed by NASA JPL to measure the speed and direction of ocean surface winds. Simulations performed to estimate the performance of the instrument prior to its launch have indicated that the mid-swath accuracy is worse than that of the rest of the swath. This behavior is a general characteristic of scanning pencil beam scatterometers. For SeaWinds, the accuracy of the rest of the swath, and the size of the swath are such that the instrument meets its science requirements despite mid-swath shortcomings. However, by understanding the problem at mid-swath, we can improve the performance there as well. We discuss the underlying causes of the problem in detail and propose a new wind retrieval algorithm which improves mid-swath performance. The directional discrimination ability of the instrument varies with cross track distance wind speed, and direction. By estimating the range of likely wind directions for each measurement cell, one can optimally apply information from neighboring cells where necessary in order to reduce random wind direction errors without significantly degrading the resolution of the resultant wind field. In this manner we are able to achieve mid-swath RMS wind direction errors as low as 15 degrees for low winds and 10 degrees for moderate to high winds, while at the same time preserving high resolution structures such as cyclones and fronts.
Music: Instrumental Techniques, Conducting.
ERIC Educational Resources Information Center
Grozan, Carl
A course in introduction to the conducting of music groups of voices or instruments is presented. The approach used is a laboratory approach in which pupils will develop skills in score reading, physical gestures, rehearsal techniques, transpositions, voice and instrument ranges. Course objectives include: (1) The pupil will identify all…
Evaluation of Students' Conceptual Understanding of Malaria
NASA Astrophysics Data System (ADS)
Poh-Ai Cheong, Irene; Treagust, David; Kyeleve, Iorhemen J.; Oh, Peck-Yoke
2010-12-01
In this study, a two-tier diagnostic test for understanding malaria was developed and administered to 314 Bruneian students in Year 12 and in a nursing diploma course. The validity, reliability, difficulty level, discriminant indices, and reading ability of the test were examined and found to be acceptable in terms of measuring students' understanding and identifying alternative conceptions with respect to malaria. Results showed that students' understanding of malaria was high for content, low for reasons, and limited and superficial for both content and reasons. The instrument revealed several common alternative conceptual understandings students' hold about malaria. The MalariaTT2 instrument developed could be used in classroom lessons for challenging alternative conceptions and enhancing conceptions of malaria.
GET: A generic electronics system for TPCs and nuclear physics instrumentation
NASA Astrophysics Data System (ADS)
Pollacco, E. C.; Grinyer, G. F.; Abu-Nimeh, F.; Ahn, T.; Anvar, S.; Arokiaraj, A.; Ayyad, Y.; Baba, H.; Babo, M.; Baron, P.; Bazin, D.; Beceiro-Novo, S.; Belkhiria, C.; Blaizot, M.; Blank, B.; Bradt, J.; Cardella, G.; Carpenter, L.; Ceruti, S.; De Filippo, E.; Delagnes, E.; De Luca, S.; De Witte, H.; Druillole, F.; Duclos, B.; Favela, F.; Fritsch, A.; Giovinazzo, J.; Gueye, C.; Isobe, T.; Hellmuth, P.; Huss, C.; Lachacinski, B.; Laffoley, A. T.; Lebertre, G.; Legeard, L.; Lynch, W. G.; Marchi, T.; Martina, L.; Maugeais, C.; Mittig, W.; Nalpas, L.; Pagano, E. V.; Pancin, J.; Poleshchuk, O.; Pedroza, J. L.; Pibernat, J.; Primault, S.; Raabe, R.; Raine, B.; Rebii, A.; Renaud, M.; Roger, T.; Roussel-Chomaz, P.; Russotto, P.; Saccà, G.; Saillant, F.; Sizun, P.; Suzuki, D.; Swartz, J. A.; Tizon, A.; Usher, N.; Wittwer, G.; Yang, J. C.
2018-04-01
General Electronics for TPCs (GET) is a generic, reconfigurable and comprehensive electronics and data-acquisition system for nuclear physics instrumentation of up to 33792 channels. The system consists of a custom-designed ASIC for signal processing, front-end cards that each house 4 ASIC chips and digitize the data in parallel through 12-bit ADCs, concentration boards to read and process the digital data from up to 16 ASICs, a 3-level trigger and master clock module to trigger the system and synchronize the data, as well as all of the associated firmware, communication and data-acquisition software. An overview of the system including its specifications and measured performances are presented.
Taylor, C D; Reynolds, S J
2001-01-01
The production of livestock in enclosed facilities has become an accepted practice, driven by the need for increased efficiency. Exposure to organic dusts, containing various bioactive components, has been identified an important risk factor for the high rate of lung disease found among workers in these environments. Assessment of organic dust exposure requires technical skills and instrumentation not readily available to most agricultural enterprises. Development of a simple, cost-effective method for measuring organic dust levels would be useful in evaluating and controlling exposures in these environments. The objective of this study was to evaluate the usefulness of the direct reading MIE PDM-3 Miniram for estimating organic dust concentrations in enclosed swine production facilities. Responses from the MIE PDM-3 Miniram were compared to gravimetric methods for total and inhalable dust. Total dust determinations were conducted in accordance with the National Institute for Occupational Safety and Health (NIOSH) method 0500. Inhalable particulate mass (IPM) sampling was conducted using SKC brand IOM (Institute of Occupational Medicine) sampling cassettes, which meet the American Conference of Governmental Industrial Hygienists ACGIH criteria for inhalable dust sampling. This study design also allowed for the comparison of traditional total dust method to the IPM method, in collecting organic dusts in an agricultural setting. Fifteen sets of side-by-side samples (Miniram, total dust, and IPM) were collected over a period of six months in a swine confinement building. There were statistically significant differences in the results provided by the three sampling methods. Measurements for inhalable dust exceeded those for total dust in eleven of fifteen samples. The Miniram time-weighted average (TWA) response to the organic dust was always the lower of the three methods. A high degree of correlation was found among all three methods. The Miniram performed well under field conditions of varying temperature and humidity. The Miniram has the potential to predict the inhalable and total dust concentrations, assuming a correction factor for the organic dust being measured is applied.
ERIC Educational Resources Information Center
Morris, Harold J.
In an effort to assess community college teachers' level of acceptance of and willingness to implement administrative directives, a survey instrument and personal data sheet were delivered to 130 public community college teachers in Mississippi. A modified Zones of Indifference instrument was used to assess respondents' attitudes towards 71…
Science Enabling ASICs and FEEs for the JUICE and JEO Missions
NASA Technical Reports Server (NTRS)
Paschalidis, Nicholas; Sittler, Ed; Cooper, John; Christian, Eric; Moore, Tom
2011-01-01
A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.
Prototype Chemiluminescent Analyzer for Measurement of Hydrazines and Nitrogen Dioxide.
1983-10-01
propellants, mono- methyihydrazine ( MMI ), 1,1-dimethy1hydrazine (UOMH), and hydrazine (Hz), as well as nitrogen dioxide (NO2 ). Preliminary studies at the USAF...large background readings, which consisted mainly of red and infrared (ir) radiation, were obtained in these instruments (2-5), optical filters were...used. This choice eliminated both the need for optical filters and the need to cool the PMTs (since bialkali tubes have much lower dark currents than
ERIC Educational Resources Information Center
Weber, David M.
2013-01-01
This study investigated the use of a student evaluation of teaching survey designed by a suburban school district. Several statistical methodologies were used to evaluate the validity and reliability of the instrument. One hundred sections of grades 6-8 reading and mathematics courses were used to examine the research question: Is the Student…
NASA Technical Reports Server (NTRS)
Mccandless, S. W.; Miller, B. P.
1974-01-01
The SEASAT satellite system is planned as a user-oriented system for timely monitoring of global ocean dynamics and mapping the global ocean geoid. The satellite instrumentation and modular concept are discussed. Operational data capabilities will include oceanographic data services, direct satellite read-out to users, and conversational retrieval and analysis of stored data. A case-study technique, generalized through physical and econometric modeling, indicates potential economic benefit from SEASAT to users in the following areas: ship routing, iceberg reconnaissance, arctic operations, Alaska pipeline ship link, and off-shore oil production.
Directional tendencies of Hebrew, Japanese, and English readers.
Nachson, I; Hatta, T
2001-08-01
Consistent left-right and right-left reading habits are associated with corresponding directional tendencies in the reproduction of horizontally displayed visual stimuli. Inconsistent reading habits should therefore be associated with inconsis tent directional tendencies. This hypothesis was tested on Japanese readers whose reading habits were inconsistent by asking them to reproduce four series of 12-item horizontal stimulus arrays. The hypothesis was partially supported by the data which showed that, like Hebrew readers who also have inconsistent reading habits, the directional tendencies shown by the 68 Japanese readers were significantly weaker on some tasks that those shown by the 16 English readers whose left-right reading habits were consistent. The data were interpreted as showing that acquired reading habits may affect directionality in perception of visual stimuli.
Reading to a Different DRUM: The Directed Reading Using Music Strategy.
ERIC Educational Resources Information Center
Marchionda, Denise B.
The Directed Reading Using Music Strategy (DRUMS) is a type of reading strategy that can lead to the teaching of reflective thinking skills, increased reading comprehension and vocabulary, along with increased motivation for learning. Research indicates that contemporary song lyrics aid reading comprehension and can be used as motivational text. A…
Miranda, Ana; Colomer, Carla; Mercader, Jessica; Fernández, M Inmaculada; Presentación, M Jesús
2015-01-01
The early assessment of the executive processes using ecologically valid instruments is essential for identifying deficits and planning actions to deal with possible adverse consequences. The present study has two different objectives. The first objective is to analyze the relationship between preschoolers' performance on tests of Working Memory and Inhibition and parents' and teachers' ratings of these executive functions (EFs) using the Behavior Rating Inventory of Executive Function (BRIEF). The second objective consists of studying the predictive value of the different EF measures (performance-based test and rating scales) on Inattention and Hyperactivity/Impulsivity behaviors and on indicators of word reading performance. The participants in the study were 209 children in the last year of preschool, their teachers and their families. Performance-based tests of Working Memory and Inhibition were administered, as well as word reading measures (accuracy and speed). The parents and teachers filled out rating scales of the EF and typical behaviors of attention deficit hyperactivity disorder (ADHD) symptomatology. Moderate correlation values were found between the different EF assessments procedures, although the results varied depending on the different domains. Metacognition Index from the BRIEF presented stronger correlations with verbal working memory tests than with inhibition tests. Both the rating scales and the performance-based tests were significant predictors of Inattention and Hyperactivity/Impulsivity behaviors and the reading achievement measures. However, the BRIEF explained a greater percentage of variance in the case of the ADHD symptomatology, while the performance-based tests explained reading achievement to a greater degree. The implications of the findings for research and clinical practice are discussed.
Miranda, Ana; Colomer, Carla; Mercader, Jessica; Fernández, M. Inmaculada; Presentación, M. Jesús
2015-01-01
The early assessment of the executive processes using ecologically valid instruments is essential for identifying deficits and planning actions to deal with possible adverse consequences. The present study has two different objectives. The first objective is to analyze the relationship between preschoolers’ performance on tests of Working Memory and Inhibition and parents’ and teachers’ ratings of these executive functions (EFs) using the Behavior Rating Inventory of Executive Function (BRIEF). The second objective consists of studying the predictive value of the different EF measures (performance-based test and rating scales) on Inattention and Hyperactivity/Impulsivity behaviors and on indicators of word reading performance. The participants in the study were 209 children in the last year of preschool, their teachers and their families. Performance-based tests of Working Memory and Inhibition were administered, as well as word reading measures (accuracy and speed). The parents and teachers filled out rating scales of the EF and typical behaviors of attention deficit hyperactivity disorder (ADHD) symptomatology. Moderate correlation values were found between the different EF assessments procedures, although the results varied depending on the different domains. Metacognition Index from the BRIEF presented stronger correlations with verbal working memory tests than with inhibition tests. Both the rating scales and the performance-based tests were significant predictors of Inattention and Hyperactivity/Impulsivity behaviors and the reading achievement measures. However, the BRIEF explained a greater percentage of variance in the case of the ADHD symptomatology, while the performance-based tests explained reading achievement to a greater degree. The implications of the findings for research and clinical practice are discussed. PMID:25972833
Kim, Young-Suk Grace; Cho, Jeung-Ryeul; Park, Soon-Gil
2017-08-01
We examined the relations of short-term memory (STM), metalinguistic awareness (phonological, morphological, and orthographic awareness), and rapid automatized naming (RAN) to word reading in Korean, a language with a relatively transparent orthography. STM, metalinguistic awareness, and RAN have been shown to be important to word reading, but the nature of the relations of STM, metalinguistic awareness, and RAN to word reading has rarely been investigated. Two alternative models were fitted. In the indirect relation model, STM was hypothesized to be indirectly related to word reading via metalinguistic awareness and RAN. In the direct and indirect relations model, STM was hypothesized to be directly and indirectly related to word reading. Results from 207 beginning readers in South Korea showed that STM was directly related to word reading as well as indirectly via metalinguistic awareness and RAN. Although the direct effect of STM was relatively small (.16), the total effect incorporating the indirect effect was substantial (.42). These results suggest that STM is an important, foundational cognitive capacity that underpins metalinguistic awareness and RAN as well as word reading, and further indicate the importance of considering both direct and indirect effects of language and cognitive skills on word reading.
Measurement Techniques for Transmit Source Clock Jitter for Weak Serial RF Links
NASA Technical Reports Server (NTRS)
Lansdowne, Chatwin A.; Schlesinger, Adam M.
2010-01-01
Techniques for filtering clock jitter measurements are developed, in the context of controlling data modulation jitter on an RF carrier to accommodate low signal-to-noise ratio thresholds of high-performance error correction codes. Measurement artifacts from sampling are considered, and a tutorial on interpretation of direct readings is included.
A comparison of three electrodes for the measurement of pH in small volumes.
Smit, A; Pollard, M; Cleaton-Jones, P; Preston, A
1997-01-01
An ion-sensitive field effect transistor (ISFET, Sentron, Sentron, Inc.) electrode was compared with a glass combination micro-electrode (MI-410, Micro-electrodes, Inc.) and a solid-state metal wire oxide pH sensor (Beetrode, World Precision Instruments, Inc.) with a liquid junction reference electrode (MERE1, World Precision Instruments, Inc.). The electrodes were assessed for linearity, reproducibility, accuracy, drift from the initial calibration between pH 4 and pH 7 and the time taken to record a stable reading. The ISFET was used to determine the pH in dental plaque samples (1 mg suspended in 20 microliters). The pH values correlated with the hydrogen ion concentration for all the electrodes (r = 0.98). The MI-410 fractured before this evaluation was completed. Coefficients of variation were 0.65% (pH 4) and 0.08% (pH 7) for the ISFET and 4.69% (pH 4) and 3.46% (pH 7) for the Beetrode. Both electrodes gave readings that differed significantly from the initial calibration, but the drift was greater for the Beetrode (F = 7.93; p = 0.0005) than the ISFET (F = 1.89; p = 0.1519). However, this drift was smaller than the change in pH as measured in dental plaque samples. The Beetrode gave a stable reading after 3.39 +/- 0.83 s and the ISFET after 2.2 +/- 0.76 s, while the MI-410 required at least 20 s. The ISFET type electrode is suitable for use in small volumes such as plaque suspensions, is easier to operate and yields results closer to the initial calibration than the Beetrode and is more robust than the MI-410 and the Beetrode.
Proof of concept demonstration for coherent beam pattern measurements of KID detectors
NASA Astrophysics Data System (ADS)
Davis, Kristina K.; Baryshev, Andrey M.; Jellema, Willem; Yates, Stephen J. C.; Ferrari, Lorenza; Baselmans, Jochem J. A.
2016-07-01
Here we summarize the initial results from a complex field radiation pattern measurement of a kinetic inductance detector instrument. These detectors are phase insensitive and have thus been limited to scalar, or amplitude-only, beam measurements. Vector beam scans, of both amplitude and phase, double the information received in comparison to scalar beam scans. Scalar beam measurements require multiple scans at varying distances along the optical path of the receiver to fully constrain the divergence angle of the optical system and locate the primary focus. Vector scans provide this information with a single scan, reducing the total measurement time required for new systems and also limiting the influence of system instabilities. The vector scan can be taken at any point along the optical axis of the system including the near-field, which makes beam measurements possible for large systems at high frequencies where these measurements may be inconceivable to be tested in-situ. Therefore, the methodology presented here should enable common heterodyne analysis for direct detector instruments. In principle, this coherent measurement strategy allows phase dependent analysis to be performed on any direct-detect receiver instrument.
Koenig, S C; Reister, C A; Schaub, J; Swope, R D; Ewert, D; Fanton, J W
1996-01-01
The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Reister, C. A.; Schaub, J.; Swope, R. D.; Ewert, D.; Fanton, J. W.; Convertino, V. A. (Principal Investigator)
1996-01-01
The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.
Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, Valeriy V; Barber, Samuel; Domning, Edward E.
2009-09-11
A new low budget slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought to operation at the ALS Optical Metrology Laboratory. The design, instrumental control and data acquisition system, initial alignment and calibration procedures, as well as the developed experimental precautions and procedures are described in detail. The capability of the DLTP to achieve sub-microradian surface slope metrology is verified via cross-comparison measurements with other high performance slope measuring instruments when measuring the same high quality test optics. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.
Reading Instruments: Objects, Texts and Museums
ERIC Educational Resources Information Center
Anderson, Katharine; Frappier, Melanie; Neswald, Elizabeth; Trim, Henry
2013-01-01
Science educators, historians of science and their students often share a curiosity about historical instruments as a tangible link between past and present practices in the sciences. We less often integrate instruments into our research and pedagogy, considering artefact study as the domain of museum specialists. We argue here that scholars and…
Design and Development of the Aircraft Instrument Comprehension Program.
ERIC Educational Resources Information Center
Higgins, Norman C.
The Aircraft Instrument Comprehension (AIC) Program is a self-instructional program designed to teach undergraduate student pilots to read instruments that indicate the position of the aircraft in flight, based on sequential instructional stages of information, prompted practice, and unprompted practice. The program includes a 36-item multiple…
Method and apparatus for instantaneous band ratioing in a reflectance radiometer
NASA Technical Reports Server (NTRS)
Goetz, Alexander F. H. (Inventor); Machida, Richard A. (Inventor)
1982-01-01
A hand-held instrument is provided to compare information from selected infrared and visible bands in the 0.4 to 2.5 micrometer range, to perform ratioing via a dividing circuit (17) and to directly read out, via a display system (18), ratio values in a continuous digital display. The dual-beam, ratioing radiometer contains two optical trains (10, 12), each having two repeater lenses (L1a, L1b and L2a, L2b) and a cooled lead sulfide detector (D1, D2). One of the trains (10) is pivotal to facilitate measurements at distances ranging from about 1 meter to infinity. The optical trains are intersected by a set of two coaxially-mounted filter wheels (F1, F2), each containing up to five interference filters and slits to pass radiation filtered by the other. Filters with band passes as narrow as 0.01 micrometer are used in the region 0.4 to 2.5 micrometers. The total time for a calibration and measurement is only a few seconds. It is known from previous field studies using prior art devices, that materials, e.g., clay minerals, and carbonate minerals such as limestone, have unique spectral properties in the 2.0 to 2.5 micrometer region. Using properly chosen spectral filters, and ratioing the signals to remove the effect of topography on the brightness measured, the instrument can be used for real-time analysis of reflecting materials in the field. Other materials in the broader range of 0.4 to 2.5 micrometers (and even beyond) could be similarly identified once the reflectance spectrum of the material is established by any means.
ARIES NDA Robot operators` manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheer, N.L.; Nelson, D.C.
1998-05-01
The ARIES NDA Robot is an automation device for servicing the material movements for a suite of Non-destructive assay (NDA) instruments. This suite of instruments includes a calorimeter, a gamma isotopic system, a segmented gamma scanner (SGS), and a neutron coincidence counter (NCC). Objects moved by the robot include sample cans, standard cans, and instrument plugs. The robot computer has an RS-232 connection with the NDA Host computer, which coordinates robot movements and instrument measurements. The instruments are expected to perform measurements under the direction of the Host without operator intervention. This user`s manual describes system startup, using the mainmore » menu, manual operation, and error recovery.« less
Airborne Validation of Spatial Properties Measured by the CALIPSO Lidar
NASA Technical Reports Server (NTRS)
McGill, Matthew J.; Vaughan, Mark A.; Trepte, Charles Reginald; Hart, William D.; Hlavka, Dennis L.; Winker, David M.; Keuhn, Ralph
2007-01-01
The primary payload onboard the Cloud-Aerosol Lidar Infrared Pathfinder Satellite Observations (CALIPSO) satellite is a dual-wavelength backscatter lidar designed to provide vertical profiling of clouds and aerosols. Launched in April 2006, the first data from this new satellite was obtained in June 2006. As with any new satellite measurement capability, an immediate post-launch requirement is to verify that the data being acquired is correct lest scientific conclusions begin to be drawn based on flawed data. A standard approach to verifying satellite data is to take a similar, or validation, instrument and fly it onboard a research aircraft. Using an aircraft allows the validation instrument to get directly under the satellite so that both the satellite instrument and the aircraft instrument are sensing the same region of the atmosphere. Although there are almost always some differences in the sampling capabilities of the two instruments, it is nevertheless possible to directly compare the measurements. To validate the measurements from the CALIPSO lidar, a similar instrument, the Cloud Physics Lidar, was flown onboard the NASA high-altitude ER-2 aircraft during July- August 2006. This paper presents results to demonstrate that the CALIPSO lidar is properly calibrated and the CALIPSO Level 1 data products are correct. The importance of the results is to demonstrate to the research community that CALIPSO Level 1 data can be confidently used for scientific research.
NASA Technical Reports Server (NTRS)
Haines, R. F.
1978-01-01
Eight commercial pilots were shown 50 colored, high fidelity slides of a standard instrument panel (IP) with the needle positions of each instrument varying from slide to slide and then 50 slides of a head-up display (HUD) symbology format which contained an equivalent amount of flight-related information as the instrument panel slides. All stimuli were presented under controlled, static viewing conditions that allowed the measurement of the speed and accuracy with which one randomly selected flight parameter on each slide could be read. The subject did not know which parameter would be requested and, therefore, had to remember the total set of information in order to answer the question correctly. The results showed that from 6.6 - 8.7 sec total viewing time was required to correctly extract altitude, airspeed, heading, VSI, or ADI from the IP slides and from 6.1 to 7.4 sec for the HUD slides.
Aeronautic Instruments. Section V : Power Plant Instruments
NASA Technical Reports Server (NTRS)
Washburn, G E; Sylvander, R C; Mueller, E F; Wilhelm, R M; Eaton, H N; Warner, John A C
1923-01-01
Part 1 gives a general discussion of the uses, principles, construction, and operation of airplane tachometers. Detailed description of all available instruments, both foreign and domestic, are given. Part 2 describes methods of tests and effect of various conditions encountered in airplane flight such as change of temperature, vibration, tilting, and reduced air pressure. Part 3 describes the principal types of distance reading thermometers for aircraft engines, including an explanation of the physical principles involved in the functioning of the instruments and proper filling of the bulbs. Performance requirements and testing methods are given and a discussion of the source of error and results of tests. Part 4 gives methods of tests and calibration, also requirements of gauges of this type for the pressure measurement of the air pressure in gasoline tanks and the engine oil pressure on airplanes. Part 5 describes two types of gasoline gauges, the float type and the pressure type. Methods of testing and calibrating gasoline depth gauges are given. The Schroeder, R. A. E., and the Mark II flowmeters are described.
Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W
2015-09-01
Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a limited sample size prevented formal validation.
ERIC Educational Resources Information Center
Abu-Snoubar, Tamador Khalaf
2017-01-01
This quantitative study aimed to investigate and compare the use of metacognitive reading Strategies among English as a foreign language students at Al-Balqa Applied University based on their academic field of study. The Survey of Reading Strategies (SORS) (Mokhtari & Sheory, 2002) was the instrument employed. This survey divides the…
Study of Thai Language Oral Reading Problems for Students with Down Syndrome: Grade Range 1
ERIC Educational Resources Information Center
Kaewchote, Nantawan; Chongchaikit, Maturos
2011-01-01
The purpose of the study was to explore the Thai Language Oral Reading Problems of students with Down syndrome, Grade Range1 at Watnonsaparam School, Saraburi Thailand in favor of Web Quest Lessons Development Enhancing Oral Reading Skills of Down syndrome Students. The research instruments were the 2 observation forms on Thai Language Reading…
The Design and Implementation of a Read Prediction Buffer
1992-12-01
City, State, and ZIP Code) 7b ADDRESS (City, State. and ZIP Code) 8a. NAME OF FUNDING /SPONSORING 8b. OFFICE SYMBOL 9 PROCUREMENT INSTRUMENT... 9 E. THESIS STRUCTURE.. . .... ............... 9 II. READ PREDICTION ALGORITHM AND BUFFER DESIGN 10 A. THE READ PREDICTION ALGORITHM...29 Figure 9 . Basic Multiplexer Cell .... .......... .. 30 Figure 10. Block Diagram Simulation Labels ......... 38 viii I. INTRODUCTION A
On Trial: the Compatibility of Measurement in the Physical and Social Sciences
NASA Astrophysics Data System (ADS)
Cano, S. J.; Vosk, T.; Pendrill, L. R.; Stenner, A. J.
2016-11-01
In this paper, we put social measurement on trial: providing two perspectives arguing why measurement in the social and in the physical sciences are incompatible and counter with two perspectives supporting compatibility. For the case ‘against’, we first argue that there is a lack of definition in the social sciences. Thus, while measurement in the physical sciences is supported by empirical evidence, calibrated instruments, and predictive theory that work together to test the quantitative nature of properties, measurement in the social sciences, in the main, rests on a vague, discretionary definition of measurement that places hardly any restrictions on empirical data, does not require calibrated instruments, and rarely articulates predictive theories. The second argument for the case ‘against’ introduces the problem associated with psychometrics, including different approaches, methodologies, criteria for success and failure, and considerations as to what counts as measurement. Making the first case ‘for’, we highlight practical principles for improved social measurement including units, laws, theory, and metrology. The second argument ‘for’ introduces the exemplar of the Lexile Framework for reading that exploits metrological principles and parallels the paths taken by, for example, thermometry. We conclude by proposing a way forward potentially applicable to both physical and social measurement, in which inferences are modelled in terms of a measurement system, where specifically the output of the instrument in response to probing the object (‘entity’) is a performance metric, i.e. how well the set-up performs the assessment.
Electromagnetic sensors for general lightning application
NASA Technical Reports Server (NTRS)
Baum, C. E.; Breen, E. L.; Onell, J. P.; Moore, C. B.; Sower, G. D.
1980-01-01
Electromagnetic sensors for general lightning applications in measuring environment are discussed as well as system response to the environment. This includes electric and magnetic fields, surface current and charge densities, and currents on conductors. Many EMP sensors are directly applicable to lightning measurements, but there are some special cases of lightning measurements involving direct strikes which require special design considerations for the sensors. The sensors and instrumentation used by NMIMT in collecting data on lightning at South Baldy peak in central New Mexico during the 1978 and 1979 lightning seasons are also discussed. The Langmuir Laboratory facilities and details of the underground shielded instrumentation room and recording equipment are presented.
ERIC Educational Resources Information Center
Branagan, William Tyler; Swanbrow Becker, Martin A.
2018-01-01
The present study used an analog design with three vignettes portraying homework administrations at three levels of therapist directiveness (low, medium, and high) and the Therapeutic Reactance Scale to measure participant reactance. Participants (N = 436) read the vignettes and completed the Homework Completion Scale (HCS), Counseling…
A retarding ion mass spectrometer for the Dynamics Explorer-1
NASA Technical Reports Server (NTRS)
Wright, W.
1985-01-01
The Retarding Ion Mass Spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.
NASA Technical Reports Server (NTRS)
1979-01-01
NASA's Ames Research Center has designed a simple but medically important device--one which holds temperature probes, called thermistors, to a person's skin without affecting the characteristics of the skin segment being measured. The device improves the accuracy of skin surface temperature measurements, valuable data in health evaluation. The need for such a device was recognized in the course of life science experiments at Ames. In earlier methods, the sensing head of the temperature probe was affixed to the patient's skin by tape or elastic bands. This created a heat variance which altered skin temperature readings. The Ames-developed thermistor holder is a plastic ring with tab extensions, shown in the upper photo on the chest, arm and leg of the patient undergoing examination. The ring holds the sensing head of the temperature probe and provides firm, constant pressure between the skin and the probe. The tabs help stabilize the ring and provide attachment points for the fastening tape or bands, which do not directly touch the sensor. With this new tool, it is possible to determine more accurately the physiological effects of strenuous exercise, particularly on the treadmill. The holder is commercially available from Yellow Springs Instrument Company, Inc., Yellow Springs, Ohio, which is producing the device under a NASA patent license.
Karahmadi, Mojgan; Shakibayee, Fereshteh; Amirian, Hushang; Bagherian-Sararoudi, Reza; Maracy, Mohammad Reza
2014-01-01
Objective: The present study aimed to evaluate the effect of parenting education on improvement of reading and writing disabilities in children. Methods: A randomized controlled trial was done on primary school students with reading and writing disabilities and their mothers. The subjects were divided into three groups with 26 members in each group. The first group (mothers’ education group) received 6 one-hour new educational sessions. The second group (standard group) received 12-15 standard educational sessions for learning disability, and the third group (control group) which consisted of students with learning disability did not receive any treatments. Research instruments included reading and writing tests, and demographic questionnaire. The three groups were evaluated via pretest and posttests at baseline and after one and three months of educational interventions. Data were analyzed using the chi-square, t-test, and repeated measures multivariate analysis of variance (MANOVA). Results: The mean reading speed had the most progression in the mothers' education group. Comparison among reading speed, reading accuracy, and spelling scores has been statistically significant (F 2, 6 = 90.64;p < 0.001) but the mean of these scores has been insignificant among the three groups (F 2, 67 = 0.583;p > 0.05). The mean reading accuracy, mostly increased after 3-month interventions in the mothers group. The control group had the lowest mean reading accuracy scores. Conclusion: Parenting education in mothers had a positive effect on the treatment of children with reading and writing disabilities. Declaration of interest: None. Clinical Trial Registration-URL: http://www.irct.ir. Unique identifier: IRCT201101205653N1. PMID:24995030
Colé, Pascale; Cavalli, Eddy; Duncan, Lynne G.; Theurel, Anne; Gentaz, Edouard; Sprenger-Charolles, Liliane; El-Ahmadi, Abdessadek
2018-01-01
Children from low-SES families are known to show delays in aspects of language development which underpin reading acquisition such as vocabulary and listening comprehension. Research on the development of morphological skills in this group is scarce, and no studies exist in French. The present study investigated the involvement of morphological knowledge in the very early stages of reading acquisition (decoding), before reading comprehension can be reliably assessed. We assessed listening comprehension, receptive vocabulary, phoneme awareness, morphological awareness as well as decoding, word reading and non-verbal IQ in 703 French first-graders from low-SES families after 3 months of formal schooling (November). Awareness of derivational morphology was assessed using three oral tasks: Relationship Judgment (e.g., do these words belong to the same family or not? heat-heater … ham-hammer); Lexical Sentence Completion [e.g., Someone who runs is a …? (runner)]; and Non-lexical Sentence Completion [e.g., Someone who lums is a…? (lummer)]. The tasks differ on implicit/explicit demands and also tap different kinds of morphological knowledge. The Judgement task measures the phonological and semantic properties of the morphological relationship and the Sentence Completion tasks measure knowledge of morphological production rules. Data were processed using a graphical modeling approach which offers key information about how skills known to be involved in learning to read are organized in memory. This modeling approach was therefore useful in revealing a potential network which expresses the conditional dependence structure between skills, after which recursive structural equation modeling was applied to test specific hypotheses. Six main conclusions can be drawn from these analyses about low SES reading acquisition: (1) listening comprehension is at the heart of the reading acquisition process; (2) word reading depends directly on phonemic awareness and indirectly on listening comprehension; (3) decoding depends on word reading; (4) Morphological awareness and vocabulary have an indirect influence on word reading via both listening comprehension and phoneme awareness; (5) the components of morphological awareness assessed by our tasks have independent relationships with listening comprehension; and (6) neither phonemic nor morphological awareness influence vocabulary directly. The implications of these results with regard to early reading acquisition among low SES groups are discussed. PMID:29725313
Colé, Pascale; Cavalli, Eddy; Duncan, Lynne G; Theurel, Anne; Gentaz, Edouard; Sprenger-Charolles, Liliane; El-Ahmadi, Abdessadek
2018-01-01
Children from low-SES families are known to show delays in aspects of language development which underpin reading acquisition such as vocabulary and listening comprehension. Research on the development of morphological skills in this group is scarce, and no studies exist in French. The present study investigated the involvement of morphological knowledge in the very early stages of reading acquisition (decoding), before reading comprehension can be reliably assessed. We assessed listening comprehension, receptive vocabulary, phoneme awareness, morphological awareness as well as decoding, word reading and non-verbal IQ in 703 French first-graders from low-SES families after 3 months of formal schooling (November). Awareness of derivational morphology was assessed using three oral tasks: Relationship Judgment (e.g., do these words belong to the same family or not? heat-heater … ham-hammer); Lexical Sentence Completion [e.g., Someone who runs is a …? (runner)]; and Non-lexical Sentence Completion [e.g., Someone who lums is a…? (lummer)]. The tasks differ on implicit/explicit demands and also tap different kinds of morphological knowledge. The Judgement task measures the phonological and semantic properties of the morphological relationship and the Sentence Completion tasks measure knowledge of morphological production rules. Data were processed using a graphical modeling approach which offers key information about how skills known to be involved in learning to read are organized in memory. This modeling approach was therefore useful in revealing a potential network which expresses the conditional dependence structure between skills, after which recursive structural equation modeling was applied to test specific hypotheses. Six main conclusions can be drawn from these analyses about low SES reading acquisition: (1) listening comprehension is at the heart of the reading acquisition process; (2) word reading depends directly on phonemic awareness and indirectly on listening comprehension; (3) decoding depends on word reading; (4) Morphological awareness and vocabulary have an indirect influence on word reading via both listening comprehension and phoneme awareness; (5) the components of morphological awareness assessed by our tasks have independent relationships with listening comprehension; and (6) neither phonemic nor morphological awareness influence vocabulary directly. The implications of these results with regard to early reading acquisition among low SES groups are discussed.
ERIC Educational Resources Information Center
Kim, Young-Suk Grace
2017-01-01
Pathways of relations of language, cognitive, and literacy skills (i.e., working memory, vocabulary, grammatical knowledge, inference, comprehension monitoring, word reading, and listening comprehension) to reading comprehension were examined by comparing four variations of direct and indirect effects model of reading. Results from 350…
Martinussen, Rhonda; Grimbos, Teresa; Ferrari, Julia L. S.
2014-01-01
This study investigated the contribution of naming speed and phonemic awareness to teacher inattention ratings and word-level reading proficiency in 79 first grade children (43 boys, 36 girls). Participants completed the cognitive and reading measures midway through the school year. Teacher ratings of inattention were obtained for each child at the same time point. A path analysis revealed that behavioral inattention had a significant direct effect on word reading proficiency as well as significant indirect effects through phonemic awareness and naming speed. For pseudoword reading proficiency, the effects of inattention were indirect only through phonemic awareness and naming speed. A regression analysis indicated that naming speed, but not phonemic awareness, was significantly associated with teacher inattention ratings controlling for word reading proficiency. The findings highlight the need to better understand the role of behavioral inattention in the development of emergent literacy skills and reading proficiency. PMID:25178628
Vision Problems and Reduced Reading Outcomes in Queensland Schoolchildren.
Hopkins, Shelley; Sampson, Geoff P; Hendicott, Peter L; Wood, Joanne M
2017-03-01
To assess the relationship between vision and reading outcomes in Indigenous and non-Indigenous schoolchildren to determine whether vision problems are associated with lower reading outcomes in these populations. Vision testing and reading assessments were performed on 508 Indigenous and non-Indigenous schoolchildren in Queensland, Australia divided into two age groups: Grades 1 and 2 (6-7 years of age) and Grades 6 and 7 (12-13 years of age). Vision parameters measured included cycloplegic refraction, near point of convergence, heterophoria, fusional vergence range, rapid automatized naming, and visual motor integration. The following vision conditions were then classified based on the vision findings: uncorrected hyperopia, convergence insufficiency, reduced rapid automatized naming, and delayed visual motor integration. Reading accuracy and reading comprehension were measured with the Neale reading test. The effect of uncorrected hyperopia, convergence insufficiency, reduced rapid automatized naming, and delayed visual motor integration on reading accuracy and reading comprehension were investigated with ANCOVAs. The ANCOVAs explained a significant proportion of variance in both reading accuracy and reading comprehension scores in both age groups, with 40% of the variation in reading accuracy and 33% of the variation in reading comprehension explained in the younger age group, and 27% and 10% of the variation in reading accuracy and reading comprehension, respectively, in the older age group. The vision parameters of visual motor integration and rapid automatized naming were significant predictors in all ANCOVAs (P < .01). The direction of the relationship was such that reduced reading results were explained by reduced visual motor integration and rapid automatized naming results. Both reduced rapid automatized naming and visual motor integration were associated with poorer reading outcomes in Indigenous and non-Indigenous children. This is an important finding given the recent emphasis placed on Indigenous children's reading skills and the fact that reduced rapid automatized naming and visual motor integration skills are more common in this group.
Oxford Optronix MPM 3S: a clinical assessment of a microvascular perfusion monitor.
Dryden, C M; Gray, W M; Asbury, A J
1992-01-01
The Oxford Optronix MPM 3S is a new microvascular perfusion monitor which is promoted as a device for use in the operating theatre. It uses a semiconductor laser diode and applies the Doppler principle to derive a semi-quantitative estimation of microvascular flow. We assessed this instrument with eight healthy volunteers who each performed eight different orthostatic arm manoeuvres while forearm skin blood flow was monitored. The different manoeuvres caused statistically significant changes in the instrument's reading which generally were consistent with expected changes in blood flow. The monitor also was assessed in the theatre environment with four anaesthetized patients. It proved easy to use, and was not subject to electrical interference from other equipment including short-wave diathermy. The major practical limitation of the technique is the semi-quantitative nature of the measurement. The instrument appears to have potential clinical uses in plastic and vascular surgery.
Measuring Thermodynamic Properties of Metals and Alloys With Knudsen Effusion Mass Spectrometry
NASA Technical Reports Server (NTRS)
Copland, Evan H.; Jacobson, Nathan S.
2010-01-01
This report reviews Knudsen effusion mass spectrometry (KEMS) as it relates to thermodynamic measurements of metals and alloys. First, general aspects are reviewed, with emphasis on the Knudsen-cell vapor source and molecular beam formation, and mass spectrometry issues germane to this type of instrument are discussed briefly. The relationship between the vapor pressure inside the effusion cell and the measured ion intensity is the key to KEMS and is derived in detail. Then common methods used to determine thermodynamic quantities with KEMS are discussed. Enthalpies of vaporization, the fundamental measurement, are determined from the variation of relative partial pressure with temperature using the second-law method or by calculating a free energy of formation and subtracting the entropy contribution using the third-law method. For single-cell KEMS instruments, measurements can be used to determine the partial Gibbs free energy if the sensitivity factor remains constant over multiple experiments. The ion-current ratio method and dimer-monomer method are also viable in some systems. For a multiple-cell KEMS instrument, activities are obtained by direct comparison with a suitable component reference state or a secondary standard. Internal checks for correct instrument operation and general procedural guidelines also are discussed. Finally, general comments are made about future directions in measuring alloy thermodynamics with KEMS.
Hecker, Christoph; Hook, Simon; van der Meijde, Mark; Bakker, Wim; van der Werff, Harald; Wilbrink, Henk; van Ruitenbeek, Frank; de Smeth, Boudewijn; van der Meer, Freek
2011-01-01
In this article we describe a new instrumental setup at the University of Twente Faculty ITC with an optimized processing chain to measure absolute directional-hemispherical reflectance values of typical earth science samples in the 2.5 to 16 μm range. A Bruker Vertex 70 FTIR spectrometer was chosen as the base instrument. It was modified with an external integrating sphere with a 30 mm sampling port to allow measuring large, inhomogeneous samples and quantitatively compare the laboratory results to airborne and spaceborne remote sensing data. During the processing to directional-hemispherical reflectance values, a background radiation subtraction is performed, removing the effect of radiance not reflected from the sample itself on the detector. This provides more accurate reflectance values for low-reflecting samples. Repeat measurements taken over a 20 month period on a quartz sand standard show that the repeatability of the system is very high, with a standard deviation ranging between 0.001 and 0.006 reflectance units depending on wavelength. This high level of repeatability is achieved even after replacing optical components, re-aligning mirrors and placement of sample port reducers. Absolute reflectance values of measurements taken by the instrument here presented compare very favorably to measurements of other leading laboratories taken on identical sample standards. PMID:22346683
Hecker, Christoph; Hook, Simon; van der Meijde, Mark; Bakker, Wim; van der Werff, Harald; Wilbrink, Henk; van Ruitenbeek, Frank; de Smeth, Boudewijn; van der Meer, Freek
2011-01-01
In this article we describe a new instrumental setup at the University of Twente Faculty ITC with an optimized processing chain to measure absolute directional-hemispherical reflectance values of typical earth science samples in the 2.5 to 16 μm range. A Bruker Vertex 70 FTIR spectrometer was chosen as the base instrument. It was modified with an external integrating sphere with a 30 mm sampling port to allow measuring large, inhomogeneous samples and quantitatively compare the laboratory results to airborne and spaceborne remote sensing data. During the processing to directional-hemispherical reflectance values, a background radiation subtraction is performed, removing the effect of radiance not reflected from the sample itself on the detector. This provides more accurate reflectance values for low-reflecting samples. Repeat measurements taken over a 20 month period on a quartz sand standard show that the repeatability of the system is very high, with a standard deviation ranging between 0.001 and 0.006 reflectance units depending on wavelength. This high level of repeatability is achieved even after replacing optical components, re-aligning mirrors and placement of sample port reducers. Absolute reflectance values of measurements taken by the instrument here presented compare very favorably to measurements of other leading laboratories taken on identical sample standards.
Göbel, Silke M
2015-01-01
Most adults and children in cultures where reading text progresses from left to right also count objects from the left to the right side of space. The reverse is found in cultures with a right-to-left reading direction. The current set of experiments investigated whether vertical counting in the horizontal plane is also influenced by reading direction. Participants were either from a left-to-right reading culture (UK) or from a mixed (left-to-right and top-to-bottom) reading culture (Hong Kong). In Experiment 1, native English-speaking children and adults and native Cantonese-speaking children and adults performed three object counting tasks. Objects were presented flat on a table in a horizontal, vertical, and square display. Independent of culture, the horizontal array was mostly counted from left to right. While the majority of English-speaking children counted the vertical display from bottom to top, the majority of the Cantonese-speaking children as well as both Cantonese- and English-speaking adults counted the vertical display from top to bottom. This pattern was replicated in the counting pattern for squares: all groups except the English-speaking children started counting with the top left coin. In Experiment 2, Cantonese-speaking adults counted a square array of objects after they read a text presented to them either in left-to-right or in top-to-bottom reading direction. Most Cantonese-speaking adults started counting the array by moving horizontally from left to right. However, significantly more Cantonese-speaking adults started counting with a top-to-bottom movement after reading the text presented in a top-to-bottom reading direction than in a left-to-right reading direction. Our results show clearly that vertical counting in the horizontal plane is influenced by longstanding as well as more recent experience of reading direction.
NASA Technical Reports Server (NTRS)
Warren, W. H., Jr.
1982-01-01
The machine-readable version of the first Santiago-Pulkovo Fundamental Stars catalog is described. It is intended to enable users to read and process the computerized catalog without the problems and guesswork often associated with such a task. The source reference should be consulted for additional details regarding the measurements, instrument characteristics, reductions, construction of the quasi-absolute system of right ascension, and star positions in the catalog.
A Java program for LRE-based real-time qPCR that enables large-scale absolute quantification.
Rutledge, Robert G
2011-03-02
Linear regression of efficiency (LRE) introduced a new paradigm for real-time qPCR that enables large-scale absolute quantification by eliminating the need for standard curves. Developed through the application of sigmoidal mathematics to SYBR Green I-based assays, target quantity is derived directly from fluorescence readings within the central region of an amplification profile. However, a major challenge of implementing LRE quantification is the labor intensive nature of the analysis. Utilizing the extensive resources that are available for developing Java-based software, the LRE Analyzer was written using the NetBeans IDE, and is built on top of the modular architecture and windowing system provided by the NetBeans Platform. This fully featured desktop application determines the number of target molecules within a sample with little or no intervention by the user, in addition to providing extensive database capabilities. MS Excel is used to import data, allowing LRE quantification to be conducted with any real-time PCR instrument that provides access to the raw fluorescence readings. An extensive help set also provides an in-depth introduction to LRE, in addition to guidelines on how to implement LRE quantification. The LRE Analyzer provides the automated analysis and data storage capabilities required by large-scale qPCR projects wanting to exploit the many advantages of absolute quantification. Foremost is the universal perspective afforded by absolute quantification, which among other attributes, provides the ability to directly compare quantitative data produced by different assays and/or instruments. Furthermore, absolute quantification has important implications for gene expression profiling in that it provides the foundation for comparing transcript quantities produced by any gene with any other gene, within and between samples.
A Java Program for LRE-Based Real-Time qPCR that Enables Large-Scale Absolute Quantification
Rutledge, Robert G.
2011-01-01
Background Linear regression of efficiency (LRE) introduced a new paradigm for real-time qPCR that enables large-scale absolute quantification by eliminating the need for standard curves. Developed through the application of sigmoidal mathematics to SYBR Green I-based assays, target quantity is derived directly from fluorescence readings within the central region of an amplification profile. However, a major challenge of implementing LRE quantification is the labor intensive nature of the analysis. Findings Utilizing the extensive resources that are available for developing Java-based software, the LRE Analyzer was written using the NetBeans IDE, and is built on top of the modular architecture and windowing system provided by the NetBeans Platform. This fully featured desktop application determines the number of target molecules within a sample with little or no intervention by the user, in addition to providing extensive database capabilities. MS Excel is used to import data, allowing LRE quantification to be conducted with any real-time PCR instrument that provides access to the raw fluorescence readings. An extensive help set also provides an in-depth introduction to LRE, in addition to guidelines on how to implement LRE quantification. Conclusions The LRE Analyzer provides the automated analysis and data storage capabilities required by large-scale qPCR projects wanting to exploit the many advantages of absolute quantification. Foremost is the universal perspective afforded by absolute quantification, which among other attributes, provides the ability to directly compare quantitative data produced by different assays and/or instruments. Furthermore, absolute quantification has important implications for gene expression profiling in that it provides the foundation for comparing transcript quantities produced by any gene with any other gene, within and between samples. PMID:21407812
USDA-ARS?s Scientific Manuscript database
Chlorophyll is an indicator of crop health and productivity. Measuring chlorophyll is usually done directly and requires significant time and resources. Indirect measurement of chlorophyll density using a handheld portable chlorophyll meter can reduce time. However, this information is very limit...
NASA Technical Reports Server (NTRS)
Joiner, Reyann; Kobayashi, Ken; Winebarger, Amy; Champey, Patrick
2014-01-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument currently being developed by NASA's Marshall Space Flight Center (MSFC), the National Astronomical Observatory of Japan (NAOJ), and other partners. The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's chromosphere. The polarized spectrum imaged by the CCD cameras will capture information about the local magnetic field, allowing for measurements of magnetic strength and structure. In order to make accurate measurements of this effect, the performance characteristics of the three on- board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, read noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of 2.0+/- 0.5 e--/DN, a read noise level less than 25e-, a dark current level which is less than 10e-/pixel/s, and a residual non- linearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.
Design of Advanced Atmospheric Water Vapor Differential Absorption Lidar (DIAL) Detection System
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Luck, William S., Jr.; DeYoung, Russell J.
1999-01-01
The measurement of atmospheric water vapor is very important for understanding the Earth's climate and water cycle. The lidar atmospheric sensing experiment (LASE) is an instrument designed and operated by the Langley Research Center for high precision water vapor measurements. The design details of a new water vapor lidar detection system that improves the measurement sensitivity of the LASE instrument by a factor of 10 are discussed. The new system consists of an advanced, very low noise, avalanche photodiode (APD) and a state-of-the-art signal processing circuit. The new low-power system is also compact and lightweight so that it would be suitable for space flight and unpiloted atmospheric vehicles (UAV) applications. The whole system is contained on one small printed circuit board (9 x 15 sq cm). The detection system is mounted at the focal plane of a lidar receiver telescope, and the digital output is read by a personal computer with a digital data acquisition card.
High Energy 2-Micron Solid-State Laser Transmitter for NASA's Airborne CO2 Measurements
NASA Technical Reports Server (NTRS)
Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta; Bai, Yingxin
2012-01-01
A 2-micron pulsed, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric CO2 concentration measurements via direct detection method is being developed at NASA Langley Research Center. This instrument will provide an alternate approach to measure atmospheric CO2 concentrations with significant advantages. A high energy pulsed approach provides high-precision measurement capability by having high signal-to-noise level and unambiguously eliminates the contamination from aerosols and clouds that can bias the IPDA measurement.
Pragmatics in pre-schoolers with language impairments.
Geurts, Hilde; Embrechts, Mariëtte
2010-01-01
Pragmatic assessment methods are very diverse and differ in informant type. Some rely on parents, others on teachers/professionals and some directly test pragmatic abilities in the children themselves. A widely used pragmatic parent questionnaire is the Children's Communication Checklist--2 (CCC-2). However, it is not known how scores on the CCC-2 relate to direct measures of pragmatics. The aim of the current study is determine whether children's language patterns on pragmatics obtained with a parent questionnaire were converging with findings when the children were directly tested with a pragmatic test. The CCC-2 and the Nijmegen Pragmatics Test (NPT) were applied to 24 pre-schoolers (aged 4-7 years) with various language impairments and 33 age-matched typically developing pre-schoolers. Both pragmatic language instruments clearly differentiated between pre-schoolers with language impairments and those without language impairments. However, the obtained correlations between the different measures were low to moderate. The specificity of each of the instruments was sufficient, but the sensitivity was generally poor. The instruments were not always converging, but when the instruments did converge the obtained results were valid. However, the obtained high specificity and relatively low sensitivity values for each of the instruments showed that better cut-off scores are needed. When only one of the instruments indicated the absence or presence of language impairments, one needs to be careful in concluding whether or not there are indeed language impairments.
Shared Reading: assessing the intrinsic value of a literature-based health intervention.
Longden, Eleanor; Davis, Philip; Billington, Josie; Lampropoulou, Sofia; Farrington, Grace; Magee, Fiona; Walsh, Erin; Corcoran, Rhiannon
2015-12-01
Public health strategies have placed increasing emphasis on psychosocial and arts-based strategies for promoting well-being. This study presents preliminary findings for a specific literary-based intervention, Shared Reading, which provides community-based spaces in which individuals can relate with both literature and one another. A 12-week crossover design was conducted with 16 participants to compare benefits associated with six sessions of Shared Reading versus a comparison social activity, Built Environment workshops. Data collected included quantitative self-report measures of psychological well-being, as well as transcript analysis of session recordings and individual video-assisted interviews. Qualitative findings indicated five intrinsic benefits associated with Shared Reading: liveness, creative inarticulacy, the emotional, the personal and the group (or collective identity construction). Quantitative data additionally showed that the intervention is associated with enhancement of a sense of 'Purpose in Life'. Limitations of the study included the small sample size and ceiling effects created by generally high levels of psychological well-being at baseline. The therapeutic potential of reading groups is discussed, including the distinction between instrumental and intrinsic value within arts-and-health interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA Technical Reports Server (NTRS)
Tolefson, H. B.
1946-01-01
Tables I and II of this report summarize the gust and draft velocity data for thunderstorm flights 25 and 26 of August 21, 1946 and August 22, 1946, respectively. These dta were evaluated from records of NACA instruments installed in P-61C airplanes and are of the type presented in reference 1 for previous flights. Table III summarizes the readings of a milliammeter which was used in conjunction with other equipment to indicate ambient air temperature during thunderstorm surveys. These data were read from motion-picture records of the instrument and include all cases in which variations in the instrument indications were noted during the present flights.
NASA Technical Reports Server (NTRS)
Tolefson, H. B.
1947-01-01
Tables I and II of this report summarize the gust and draft velocity data for thunderstorm flights 31, 32, and 33 of September 5, 1946, September 6, 1946, and September 10, 1946, respectively. These data were evaluated from records of NACA instruments installed in P-61C airplanes and are of the type presented for previous flights. Table III summarizes the readings of a milliammeter which was used in conjunction with other equipment to indicate ambient air temperature during thunderstorm surveys. These data were read from motion-picture records of the instrument and include all cases in which variations in the instrument indications were noted for the present flights.
ERIC Educational Resources Information Center
Garreton, Rodrigo; Terdy, Dennis
In a study prompted by the need to standardize the reporting of educational progress of adult language minority students in Illinois, a commonly used adult English-as-a-Second-Language (ESL) reading test was compared with two frequently used Adult Basic Education (ABE) reading tests. The testing instruments used were the ELSA (English Language…
ERIC Educational Resources Information Center
Gudan, Sirkka
A review of the literature indicates that the Nelson-Denny Reading Test (NDRT) may be a viable instrument for screening students and predicting their academic success in particular circumstances. In 1981, a study was conducted at Schoolcraft College to determine the extent of the relationship between the reading abilities of entering students and…
Optical performance of prototype horn-coupled TES bolometer arrays for SAFARI
NASA Astrophysics Data System (ADS)
Audley, Michael D.; de Lange, Gert; Gao, Jian-Rong; Khosropanah, Pourya; Hijmering, Richard; Ridder, Marcel L.
2016-07-01
The SAFARI Detector Test Facility is an ultra-low background optical testbed for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for SAFARI, the grating spectrometer on board the proposed SPICA satellite. The testbed contains internal cold and hot black-body illuminators and a light-pipe for illumination with an external source. We have added reimaging optics to facilitate array optical measurements. The system is now being used for optical testing of prototype detector arrays read out with frequency-domain multiplexing. We present our latest optical measurements of prototype arrays and discuss these in terms of the instrument performance.
Lee, Hachoung; Oh, Songjoo
2016-01-01
It has been suggested that reading/writing habits may influence the appreciation of pictures. For example, people who read and write in a rightward direction have an aesthetic preference for pictures that face rightward over pictures that face leftward, and vice versa. However, correlations for this phenomenon have only been found in cross-cultural studies. Will a directional change in reading/writing habits within a culture relate to changes in picture preference? Korea is a good place to research this question because the country underwent gradual changes in reading/writing direction habits, from leftward to rightward, during the 20th century. In this study, we analyzed the direction of drawings and photos published in the two oldest newspapers in Korea from 1920-2013. The results show that the direction of the drawings underwent a clear shift from the left to the right, but the direction of the photos did not change. This finding suggests a close psychological link between the habits of reading/writing and drawing that cannot be accounted for simply by an accidental correspondence across different cultures.
NASA Astrophysics Data System (ADS)
Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.
2018-05-01
The chemical composition of aerosol particles is a key aspect in determining their impact on the environment. For example, nitrogen-containing particles impact atmospheric chemistry, air quality, and ecological N deposition. Instruments that measure total reactive nitrogen (Nr = all nitrogen compounds except for N2 and N2O) focus on gas-phase nitrogen and very few studies directly discuss the instrument capacity to measure the mass of Nr-containing particles. Here, we investigate the mass quantification of particle-bound nitrogen using a custom Nr system that involves total conversion to nitric oxide (NO) across platinum and molybdenum catalysts followed by NO-O3 chemiluminescence detection. We evaluate the particle conversion of the Nr instrument by comparing to mass-derived concentrations of size-selected and counted ammonium sulfate ((NH4)2SO4), ammonium nitrate (NH4NO3), ammonium chloride (NH4Cl), sodium nitrate (NaNO3), and ammonium oxalate ((NH4)2C2O4) particles determined using instruments that measure particle number and size. These measurements demonstrate Nr-particle conversion across the Nr catalysts that is independent of particle size with 98 ± 10 % efficiency for 100-600 nm particle diameters. We also show efficient conversion of particle-phase organic carbon species to CO2 across the instrument's platinum catalyst followed by a nondispersive infrared (NDIR) CO2 detector. However, the application of this method to the atmosphere presents a challenge due to the small signal above background at high ambient levels of common gas-phase carbon compounds (e.g., CO2). We show the Nr system is an accurate particle mass measurement method and demonstrate its ability to calibrate particle mass measurement instrumentation using single-component, laboratory-generated, Nr-containing particles below 2.5 µm in size. In addition we show agreement with mass measurements of an independently calibrated online particle-into-liquid sampler directly coupled to the electrospray ionization source of a quadrupole mass spectrometer (PILS-ESI/MS) sampling in the negative-ion mode. We obtain excellent correlations (R2 = 0.99) of particle mass measured as Nr with PILS-ESI/MS measurements converted to the corresponding particle anion mass (e.g., nitrate, sulfate, and chloride). The Nr and PILS-ESI/MS are shown to agree to within ˜ 6 % for particle mass loadings of up to 120 µg m-3. Consideration of all the sources of error in the PILS-ESI/MS technique yields an overall uncertainty of ±20 % for these single-component particle streams. These results demonstrate the Nr system is a reliable direct particle mass measurement technique that differs from other particle instrument calibration techniques that rely on knowledge of particle size, shape, density, and refractive index.
ERIC Educational Resources Information Center
School Science Review, 1982
1982-01-01
Outlines methodology, demonstrations, and materials including: an inexpensive wave machine; speed of sound in carbon dioxide; diffraction grating method for measuring spectral line wavelength; linear electronic thermometer; analogy for bromine diffusion; direct reading refractice index meter; inexpensive integrated circuit spectrophotometer; and…
A comparison of four different blood gas analysers.
Kofstad, J
1981-06-01
Four automatic blood gas analysers from four different manufactures were evaluated and compared. The measurements were performed on blood representing respiratory acidosis and hypoxemia, normal conditions, and respiratory alkalosis and hyperoxemia. On each level nine complete runs were carried out, each run consisting of six replicates of each parameter (pH, Pco2 and Po2) on each instrument (six rounds). Only the directly measured parameters (pH, Pco2, Po2) were compared. The main conclusion is that the four instruments can be used alternatively, and that the differences between the values measured by the four instruments are of little clinical significance.
NASA Technical Reports Server (NTRS)
Weinstock, E. M.; Smith, J. B.; Sayres, D.; Pittman, J. V.; Allen, N.; Demusz, J.; Greenberg, M.; Rivero, M.; Anderson, J. G.
2003-01-01
We describe an instrument mounted in a pallet on the NASA WB-57 aircraft that is designed to measure the sum of gas phase and solid phase water, or total water, in cirrus clouds. Using an isokinetic inlet, a 600-watt heater mounted directly in the flow, and Lyman-alpha photofragment fluorescence technique for detection, accurate measurements of total water have been made over almost three orders of magnitude. Isokinetic flow is achieved with an actively controlled roots pump by referencing aircraft pressure, temperature, and true air speed, together with instrument flow velocity, temperature, and pressure. During CRYSTAL FACE, the instrument operated at duct temperatures sufficiently warm to completely evaporate particles up to 150 microns diameter. In flight diagnostics, intercomparison with water measured by absorption in flight, as well as intercomparisons in clear air with water vapor measured by the Harvard water vapor instrument and the JPL infrared tunable diode laser hygrometer validate the detection sensitivity of the instrument and illustrate minimal hysteresis from instrument surfaces. The simultaneous measurement of total water and water vapor in cirrus clouds yields their ice water content.
A New Instrument for Measurement of the Solar Aureole Radiance Distribution from Unstable Platforms
NASA Technical Reports Server (NTRS)
Ritter, Joseph M.; Voss, Kenneth J.
1999-01-01
A novel imaging solar aureole radiometer, which can obtain absolute radiometric measurements of the solar aureole when operated on an unstable platform is described. A CCD array is used to image the aureole, while a neutral density occulter on a long pole blocks the direct solar radiation. This ensures accurate direction registration as the sun appears in acquired images, and the total circumsolar region is measured simultaneously. The imaging nature of this instrument along with a special triggering device permit acquisition of the circumsolar sky radiance within 7.5 degrees of the center of the solar disk, and within 1 degree of the edge of the solar disk. This innovation makes possible for the first time, reliable and accurate radiometric measurements of the solar aureole from unstable mobile platforms such as ships. This allows determination small angle atmospheric scattering. The instrument has been used in field studies of atmospheric aerosols and will be used in satellite validation and calibration campaigns.
Core neuropsychological characteristics of children and adolescents with 22q11.2 deletion.
Jacobson, C; Shearer, J; Habel, A; Kane, F; Tsakanikos, E; Kravariti, E
2010-08-01
The 22q11.2 deletion syndrome (22qDS) confers high risk for intellectual disability and neuropsychological/academic impairment, although a minority of patients show average intelligence. Intellectual heterogeneity and the high prevalence of psychiatric diagnoses in earlier studies may have obscured the prototypical neuropsychological profile in 22qDS. We examined intelligence, memory, reading and mathematical processes in 31 children/adolescents with 22qDS, selected for educational underachievement and an absence of psychiatric diagnoses, using standardised, psychometrically matched instruments that specify how typical a score is for a given intelligence quotient (IQ). Corroborating earlier findings, verbal IQ was significantly superior to performance IQ; verbal memory and basic reading were relative strengths; and visual/spatial memory was a relative weakness. All four findings transcended performance characteristics that are typical of low-IQ individuals. Rote learning yielded the highest score; reading comprehension, numerical operations and mathematical reasoning were among the lowest-performed academic domains. Albeit in the expected direction, performance in the respective components could not be clearly differentiated from what is IQ-appropriate. A superiority of verbal intelligence over non-verbal intelligence, relative strengths in verbal memory and basic reading, and a relative weakness in visual/spatial memory are likely to be core characteristics of children/adolescents with 22qDS, transcending performance features that are typical of individuals with low IQ.
NASA Astrophysics Data System (ADS)
Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip S.; Wood, Ezra; Kundu, Shuvashish; Dusanter, Sébastien
2018-02-01
Ground-level ozone (O3) is an important pollutant that affects both global climate change and regional air quality, with the latter linked to detrimental effects on both human health and ecosystems. Ozone is not directly emitted in the atmosphere but is formed from chemical reactions involving volatile organic compounds (VOCs), nitrogen oxides (NOx = NO + NO2) and sunlight. The photochemical nature of ozone makes the implementation of reduction strategies challenging and a good understanding of its formation chemistry is fundamental in order to develop efficient strategies of ozone reduction from mitigation measures of primary VOCs and NOx emissions. An instrument for direct measurements of ozone production rates (OPRs) was developed and deployed in the field as part of the IRRONIC (Indiana Radical, Reactivity and Ozone Production Intercomparison) field campaign. The OPR instrument is based on the principle of the previously published MOPS instrument (Measurement of Ozone Production Sensor) but using a different sampling design made of quartz flow tubes and a different Ox (O3 and NO2) conversion-detection scheme composed of an O3-to-NO2 conversion unit and a cavity attenuated phase shift spectroscopy (CAPS) NO2 monitor. Tests performed in the laboratory and in the field, together with model simulations of the radical chemistry occurring inside the flow tubes, were used to assess (i) the reliability of the measurement principle and (ii) potential biases associated with OPR measurements. This publication reports the first field measurements made using this instrument to illustrate its performance. The results showed that a photo-enhanced loss of ozone inside the sampling flow tubes disturbs the measurements. This issue needs to be solved to be able to perform accurate ambient measurements of ozone production rates with the instrument described in this study. However, an attempt was made to investigate the OPR sensitivity to NOx by adding NO inside the instrument. This type of investigations allows checking whether our understanding of the turnover point between NOx-limited and NOx-saturated regimes of ozone production is well understood and does not require measuring ambient OPR but instead only probing the change in ozone production when NO is added. During IRRONIC, changes in ozone production rates ranging from the limit of detection (3σ) of 6.2 ppbv h-1 up to 20 ppbv h-1 were observed when 6 ppbv of NO was added into the flow tubes.
Sullivan, Michael P; Griffiths, Gina G; Moore Sohlberg, Mckay
2014-10-01
To investigate the effect of combat-related posttraumatic stress disorder (PTSD) on 4 components underlying text-level reading comprehension. A group of 17 veterans with PTSD and 17 matched control participants took part. An experimental task required participants to read and study 3-sentence paragraphs describing semantic features associated with real and unreal objects. Each paragraph was followed by true-false statements that assessed knowledge access, text memory, inference, and integration. The results revealed that the PTSD group took significantly longer than the control group to study the paragraphs. Although there was no group difference in test statement accuracy, the PTSD group also took significantly longer to respond to the test statements. Overall, the results provide evidence for the control theory of attention but suggest that more direct measures of task-irrelevant processing during text-level reading are needed. More important, the results begin to lay a foundation for developing not only diagnostic but also intervention strategies.
Patrick, Donald L; Burke, Laurie B; Gwaltney, Chad J; Leidy, Nancy Kline; Martin, Mona L; Molsen, Elizabeth; Ring, Lena
2011-12-01
The importance of content validity in developing patient reported outcomes (PRO) instruments is stressed by both the US Food and Drug Administration and the European Medicines Agency. Content validity is the extent to which an instrument measures the important aspects of concepts that developers or users purport it to assess. A PRO instrument measures the concepts most significant and relevant to a patient's condition and its treatment. For PRO instruments, items and domains as reflected in the scores of an instrument should be important to the target population and comprehensive with respect to patient concerns. Documentation of target population input in item generation, as well as evaluation of patient understanding through cognitive interviewing, can provide the evidence for content validity. Developing content for, and assessing respondent understanding of, newly developed PRO instruments for medical product evaluation will be discussed in this two-part ISPOR PRO Good Research Practices Task Force Report. Topics include the methods for generating items, documenting item development, coding of qualitative data from item generation, cognitive interviewing, and tracking item development through the various stages of research and preparing this tracking for submission to regulatory agencies. Part 1 covers elicitation of key concepts using qualitative focus groups and/or interviews to inform content and structure of a new PRO instrument. Part 2 covers the instrument development process, the assessment of patient understanding of the draft instrument using cognitive interviews and steps for instrument revision. The two parts are meant to be read together. They are intended to offer suggestions for good practices in planning, executing, and documenting qualitative studies that are used to support the content validity of PRO instruments to be used in medical product evaluation. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Compact Full-Field Ion Detector System for SmallSats Beyond LEO
NASA Technical Reports Server (NTRS)
Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.; Clark, Pamela E.; McNeil, Roger R.
2014-01-01
NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop a Compact Full-Field Ion Detector System (CFIDS). The CFIDS is designed to be an extremely compact, low cost instrument, capable of being flown on a wide variety of deep space platforms, to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments.
NASA Technical Reports Server (NTRS)
Tolefson, H. B.
1946-01-01
Summaries of the gust and draft velocities evaluated from acceleration and airspeed-altitude records taken by NACA instruments installed n P-61c airplanes participating in thunderstorm flights 12 and 13 of July 19, 1946, and July 20, 1946, respectively, are presented in tables I and II herein. These data are of the type presented in reference 1 for previous flights. Inspection of the motion picture records of the pilots' instrument panels for the present flights indicated that the milliameter connected to equipment for measuring ambient air temperature read zero throughout all traverses.