  1. Total disc replacement.

    PubMed

    Vital, J-M; Boissière, L

    2014-02-01

    Total disc replacement (TDR) (partial disc replacement will not be described) has been used in the lumbar spine since the 1980s, and more recently in the cervical spine. Although the biomechanical concepts are the same and both are inserted through an anterior approach, lumbar TDR is conventionally indicated for chronic low back pain, whereas cervical TDR is used for soft discal hernia resulting in cervicobrachial neuralgia. The insertion technique must be rigorous, with precise centering in the disc space, taking account of vascular anatomy, which is more complex in the lumbar region, particularly proximally to L5-S1. All of the numerous studies, including prospective randomized comparative trials, have demonstrated non-inferiority to fusion, or even short-term superiority regarding speed of improvement. The main implant-related complication is bridging heterotopic ossification with resulting loss of range of motion and increased rates of adjacent segment degeneration, although with an incidence lower than after arthrodesis. A sufficiently long follow-up, which has not yet been reached, will be necessary to establish definitively an advantage for TDR, particularly in the cervical spine.

  2. Reoperations Following Cervical Disc Replacement

    PubMed Central

    Skovrlj, Branko; Lee, Dong-Ho; Caridi, John Michael

    2015-01-01

    Cervical disc replacement (CDR) has emerged as an alternative surgical option to cervical arthrodesis. With increasing numbers of patients and longer follow-ups, complications related to the device and/or aging spine are growing, leaving us with a new challenge in the management and surgical revision of CDR. The purpose of this study is to review the current literature regarding reoperations following CDR and to discuss about the approaches and solutions for the current and future potential complications associated with CDR. The published rates of reoperation (mean, 1.0%; range, 0%-3.1%), revision (mean, 0.2%; range, 0%-0.5%), and removal (mean, 1.2%; range, 0%-1.9%) following CDR are low and comparable to the published rates of reoperation (mean, 1.7%; range; 0%-3.4%), revision (mean, 1.5%; range, 0%-4.7%), and removal (mean, 2.0%; range, 0%-3.4%) following cervical arthrodesis. The surgical interventions following CDR range from the repositioning to explantation followed by fusion or the reimplantation to posterior foraminotomy or fusion. Strict patient selection, careful preoperative radiographic review and surgical planning, as well as surgical technique may reduce adverse events and the need for future intervention. Minimal literature and no guidelines exist for the approaches and techniques in revision and for the removal of implants following CDR. Adherence to strict indications and precise surgical technique may reduce the number of reoperations, revisions, and removals following CDR. Long-term follow-up studies are needed, assessing the implant survivorship and its effect on the revision and removal rates. PMID:26097667

  3. Intervertebral disc replacement. Experimental study.

    PubMed

    Kostuik, J P

    1997-04-01

    Arthrodesis of the lumbosacral spine, although satisfactory for a majority of patients, has long term sequelae in 30% of patients. This is particularly true for adjacent segment degeneration. Numerous attempts at providing a mobile motion segment have been made in the past. The current status of the development of dynamic intervertebral prosthesis, including biomechanical and clinical data have been presented. The relevant material properties of plastics, ceramics, and metal are presented with the conclusion that metals currently present with the greatest longevity without undue fatigue and wear as many as 100,000,000 cycles (40 years use) as an alternative to spinal fusion. An analysis of the kinematics of the motion segment have resulted, together with the material properties in the development of a dynamic intervertebral disc for use in the lumbar spine. The disc resembles a normal motion segment. In motion stiffness and center of rotation, wear debris development in 1/300 equivalent to that of a total hip prosthesis for the same given time. Safety features include immediate screw fixation to prevent displacement, a wedge elastic (spring) shape, and a bony porous ingrowth surface. The prosthesis is constructed of cobalt chromium and titanium with minimal corrosive properties on long term testing.

  4. Material considerations for intervertebral disc replacement implants.

    PubMed

    Taksali, Sudeep; Grauer, Jonathan N; Vaccaro, Alexander R

    2004-01-01

    Cervical and lumbar disc replacements are being performed with increasing frequency. Much of the background for the development for these implants is drawn from the literature of other joint replacements that have been in evolution and use for decades. Important variables for the function and longevity of such disc arthroplasty implants are clearly defined by the material properties of the components used for their production. The most frequently considered materials are cobalt-chrome alloys, titanium alloys, stainless steels, polyethylene, polyurethane and ceramics. In addition to implant materials, the interfaces of such materials must be considered. The bearing surfaces of an implant, in particular, are at risk of wear and failure. Overall, successful, long-term total disc arthroplasty requires a thorough understanding of biomaterials and how they can be used to achieve their desired goals.

  5. Total Disc Replacement in Lumbar Degenerative Disc Diseases

    PubMed Central

    2015-01-01

    More than 10 years have passed since lumbar total disc replacement (LTDR) was introduced for the first time to the world market for the surgical management of lumbar degenerative disc disease (DDD). It seems like the right time to sum up the relevant results in order to understand where LTDR stands on now, and is heading forward to. The pathogenesis of DDD has been currently settled, but diagnosis and managements are still controversial. Fusion is recognized as golden standard of surgical managements but has various kinds of shortcomings. Lately, LTDR has been expected to replace fusion surgery. A great deal of LTDR reports has come out. Among them, more than 5-year follow-up prospective randomized controlled studies including USA IDE trials were expected to elucidate whether for LTDR to have therapeutic benefit compared to fusion. The results of these studies revealed that LTDR was not inferior to fusion. Most of clinical studies dealing with LTDR revealed that there was no strong evidence for preventive effect of LTDR against symptomatic degenerative changes of adjacent segment disease. LTDR does not have shortcomings associated with fusion. However, it has a potentiality of the new complications to occur, which surgeons have never experienced in fusion surgeries. Consequently, longer follow-up should be necessary as yet to confirm the maintenance of improved surgical outcome and to observe any very late complications. LTDR still may get a chance to establish itself as a substitute of fusion both nominally and virtually if it eases the concerns listed above. PMID:26713139

  6. Material Science in Cervical Total Disc Replacement

    PubMed Central

    Pham, Martin H.; Mehta, Vivek A.; Tuchman, Alexander; Hsieh, Patrick C.

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation. PMID:26523281

  7. Autologous adipose stem cells and polylactide discs in the replacement of the rabbit temporomandibular joint disc

    PubMed Central

    Ahtiainen, Katja; Mauno, Jari; Ellä, Ville; Hagström, Jaana; Lindqvist, Christian; Miettinen, Susanna; Ylikomi, Timo; Kellomäki, Minna; Seppänen, Riitta

    2013-01-01

    The temporomandibular joint (TMJ) disc lacks functional replacement after discectomy. We investigated tissue-engineered bilayer polylactide (PLA) discs and autologous adipose stem cells (ASCs) as a potential replacement for the TMJ disc. These ASC discs were pre-cultured either in control or in differentiation medium, including transforming growth factor (TGF)-β1 for one week. Prior to implantation, expression of fibrocartilaginous genes was measured by qRT-PCR. The control and differentiated ASC discs were implanted, respectively, in the right and left TMJs of rabbits for six (n = 5) and 12 months (n = 5). Thereafter, the excised TMJ areas were examined with cone beam computed tomography (CBCT) and histology. No signs of infection, inflammation or foreign body reactions were detected at histology, whereas chronic arthrosis and considerable condylar hypertrophy were observed in all operated joints at CBCT. The left condyle treated with the differentiated ASC discs appeared consistently smoother and more sclerotic than the right condyle. The ASC disc replacement resulted in dislocation and morphological changes in the rabbit TMJ. The ASC discs pre-treated with TGF-β1 enhanced the condylar integrity. While adverse tissue reactions were not shown, the authors suggest that with improved attachment and design, the PLA disc and biomaterial itself would hold potential for TMJ disc replacement. PMID:23720535

  8. In vitro and in silico investigations of disc nucleus replacement.

    PubMed

    Reitmaier, Sandra; Shirazi-Adl, Aboulfazl; Bashkuev, Maxim; Wilke, Hans-Joachim; Gloria, Antonio; Schmidt, Hendrik

    2012-08-07

    Currently, numerous hydrogels are under examination as potential nucleus replacements. The clinical success, however, depends on how well the mechanical function of the host structure is restored. This study aimed to evaluate the extent to and mechanisms by which surgery for nucleus replacements influence the mechanical behaviour of the disc. The effects of an annulus defect with and without nucleus replacement on disc height and nucleus pressure were measured using 24 ovine motion segments. The following cases were considered: intact; annulus incision repaired by suture and glue; annulus incision with removal and re-implantation of nucleus tissue repaired by suture and glue or plug. To identify the likely mechanisms observed in vitro, a finite-element model of a human disc (L4-L5) was employed. Both studies were subjected to physiological cycles of compression and recovery. A repaired annulus defect did not influence the disc behaviour in vitro, whereas additional nucleus removal and replacement substantially decreased disc stiffness and nucleus pressure. Model predictions demonstrated the substantial effects of reductions in replaced nucleus water content, bulk modulus and osmotic potential on disc height loss and pressure, similar to measurements. In these events, the compression load transfer in the disc markedly altered by substantially increasing the load on the annulus when compared with the nucleus. The success of hydrogels for nucleus replacements is not only dependent on the implant material itself but also on the restoration of the environment perturbed during surgery. The substantial effects on the disc response of disruptions owing to nucleus replacements can be simulated by reduced nucleus water content, elastic modulus and osmotic potential.

  9. In vitro and in silico investigations of disc nucleus replacement

    PubMed Central

    Reitmaier, Sandra; Shirazi-Adl, Aboulfazl; Bashkuev, Maxim; Wilke, Hans-Joachim; Gloria, Antonio; Schmidt, Hendrik

    2012-01-01

    Currently, numerous hydrogels are under examination as potential nucleus replacements. The clinical success, however, depends on how well the mechanical function of the host structure is restored. This study aimed to evaluate the extent to and mechanisms by which surgery for nucleus replacements influence the mechanical behaviour of the disc. The effects of an annulus defect with and without nucleus replacement on disc height and nucleus pressure were measured using 24 ovine motion segments. The following cases were considered: intact; annulus incision repaired by suture and glue; annulus incision with removal and re-implantation of nucleus tissue repaired by suture and glue or plug. To identify the likely mechanisms observed in vitro, a finite-element model of a human disc (L4–L5) was employed. Both studies were subjected to physiological cycles of compression and recovery. A repaired annulus defect did not influence the disc behaviour in vitro, whereas additional nucleus removal and replacement substantially decreased disc stiffness and nucleus pressure. Model predictions demonstrated the substantial effects of reductions in replaced nucleus water content, bulk modulus and osmotic potential on disc height loss and pressure, similar to measurements. In these events, the compression load transfer in the disc markedly altered by substantially increasing the load on the annulus when compared with the nucleus. The success of hydrogels for nucleus replacements is not only dependent on the implant material itself but also on the restoration of the environment perturbed during surgery. The substantial effects on the disc response of disruptions owing to nucleus replacements can be simulated by reduced nucleus water content, elastic modulus and osmotic potential. PMID:22337630

  10. Bryan total disc arthroplasty: a replacement disc for cervical disc disease

    PubMed Central

    Wenger, Markus; Markwalder, Thomas-Marc

    2010-01-01

    Total disc arthroplasty is a new option in the treatment of cervical degenerative disc disease. Several types of cervical disc prostheses currently challenge the gold-standard discectomy and fusion procedures. This review describes the Bryan Cervical Disc System and presents the Bryan prosthesis, its indications, surgical technique, complications, and outcomes, as given in the literature. PMID:22915917

  11. Pitfalls

    NASA Technical Reports Server (NTRS)

    Triffet, Terry

    1990-01-01

    Though potentially of great benefit to the nation, the experience of the workshop participants and their discussions with Sea Grant and Land Grant officials make it clear that the Space Grant Program must avoid certain pitfalls of the past and present if it is to be successful. The most important of these are listed and briefly discussed.

  12. Preclinical and clinical experience with a viscoelastic total disc replacement

    PubMed Central

    Rischke, Burkhard; Ross, Raymond S.; Jollenbeck, Boris A.; Zimmers, Kari B.; Defibaugh, Neal D.

    2011-01-01

    Background The purpose of this study is to describe the mechanical durability and the clinical and radiographic outcomes of a viscoelastic total disc replacement (VTDR). The human intervertebral disc is a complex, viscoelastic structure, permitting and constraining motion in 3 axes, thus providing stability. The ideal disc replacement should be viscoelastic and deformable in all directions, and it should restore disc height and angle. Methods Mechanical testing was conducted to validate the durability of the VTDR, and a clinical study was conducted to evaluate safety and performance. Fifty patients with single-level, symptomatic lumbar degenerative disc disease at L4-5 or L5-S1 were enrolled in a clinical trial at 3 European sites. Patients were assessed clinically and radiographically for 2 years by the Oswestry Disability Index (ODI), a visual analog scale (VAS), and independent radiographic analyses. Results The VTDR showed a fatigue life in excess of 50 million cycles (50-year equivalent) and a physiologically appropriate level of stiffness, motion, geometry, and viscoelasticity. We enrolled 28 men and 22 women in the clinical study, with a mean age of 40 years. Independent quantitative radiographic assessment indicated that the VTDR restored and maintained disc height and lordosis while providing physiologic motion. Mean ODI scores decreased from 48% preoperatively to 23% at 2 years’ follow-up. Mean VAS low-back pain scores decreased from 7.1 cm to 2.9 cm. Median scores indicated that half of the patient population had ODI scores below 10% and VAS low-back pain scores below 0.95 cm at 2 years. Conclusions The VTDR has excellent durability and performs clinically and radiographically as intended for the treatment of symptomatic lumbar degenerative disc disease. Clinical Relevance The VTDR is intended to restore healthy anatomic properties and stability characteristics to the spinal segment. This study is the first to evaluate a VTDR in a 50-patient

  13. [Infants of drug-addicted mothers: pitfalls of replacement therapy].

    PubMed

    Vert, Paul; Hamon, Isabelle; Hubert, Claire; Legagneur, Michel; Hascoet, Jean-Michel

    2008-05-01

    Maternal drug addiction can cause problems for the fetus and the newborn, and hamper long-term development. The prevalence of drug addiction during pregnancy varies from 1 % to more than 10 % depending on the country and the maternity unit. Management of these mothers can be further complicated by medical, social and psychological problems. Compared to methadone, heroin replacement therapy with buprenorphine provides better stabilization of the mother and causes fewer withdrawal symptoms in the newborn. Despite numerous publications on the effects of this partly preventive medication, data on buprenorphine pharmacology at birth are scarce. In this study, 20 newborns of mothers using oral buprenorphine were observed until the end of the withdrawal syndrome, when present. Buprenorphine plasma levels were determined with HPLC and mass spectrometry in the mother at delivery and in the newborn at birth (cord blood), 24 and 48 hours. Fifteen newborns were born at term (mean +/- SD birth weight 3029 +/- 273 g), and the other five between 32 and 36 weeks. All Apgar scores were > or =7. Withdrawal symptoms were observed in 8 of the 15 infants born to mothers taking buprenorphine alone, and lasted between 5 and 35 days. The newborns were classified in three groups. Groups I (N8) and II (N7) comprised newborns with and without withdrawal symptoms, respectively. In group III (N5), the mothers were polyintoxicated (as shown by urinary drug or neurotropic substance screening) and the newborns were symptomatic for 1 to 69 days. Buprenorphine plasma levels in the mothers ranged from 0 to 2.9 microg/L, suggesting large differences in adherence. At birth there was no significant difference in the mean plasma buprenorphine level between newborns with and without withdrawal symptoms; the respective values were 0.7 (0.4-1.3) and 0.5 (0-0.6) microg/L. In asymptomatic newborns (group II), buprenorphine was no longer detectable at 48 h, whereas in symptomatic newborns (group I), the mean

  14. Surgical technique for revision surgery of cervical artificial disc replacements.

    PubMed

    Onken, Julia; Meyer, Bernhard; Vajkoczy, Peter

    2017-01-01

    OBJECTIVE Cervical artificial disc replacement (C-ADR) is a widely used procedure with low risk at implantation. Few cases have been reported about the surgical techniques of C-ADR revision. The authors describe their surgical experience with the explantation of a Galileo C-ADR. METHODS Revision surgery was performed in a 58-year-old patient. Patient positioning and surgical opening techniques were performed as appropriate for anterior cervical decompression. RESULTS Revision surgery via the initial anterior approach was successful following an atraumatic removal of the implant. Fusion of the C5-6 segment was performed without complications. CONCLUSIONS In general, the authors observed recurrent nerve palsy and malpositioning of the revised implant in C-ADR revision surgery. Problems with implant removal did not occur because the fusion rate was low due to the short time between initial surgery and C-ADR revision surgery. The video can be found here: https://youtu.be/32CUEDquinc .

  15. Wnt signaling during tooth replacement in zebrafish (Danio rerio): pitfalls and perspectives

    PubMed Central

    Huysseune, Ann; Soenens, Mieke; Elderweirdt, Fien

    2014-01-01

    The canonical (β-catenin dependent) Wnt signaling pathway has emerged as a likely candidate for regulating tooth replacement in continuously renewing dentitions. So far, the involvement of canonical Wnt signaling has been experimentally demonstrated predominantly in amniotes. These studies tend to show stimulation of tooth formation by activation of the Wnt pathway, and inhibition of tooth formation when blocking the pathway. Here, we report a strong and dynamic expression of the soluble Wnt inhibitor dickkopf1 (dkk1) in developing zebrafish (Danio rerio) tooth germs, suggesting an active repression of Wnt signaling during morphogenesis and cytodifferentiation of a tooth, and derepression of Wnt signaling during start of replacement tooth formation. To further analyse the role of Wnt signaling, we used different gain-of-function approaches. These yielded disjunct results, yet none of them indicating enhanced tooth replacement. Thus, masterblind (mbl) mutants, defective in axin1, mimic overexpression of Wnt, but display a normally patterned dentition in which teeth are replaced at the appropriate times and positions. Activating the pathway with LiCl had variable outcomes, either resulting in the absence, or the delayed formation, of first-generation teeth, or yielding a regular dentition with normal replacement, but no supernumerary teeth or accelerated tooth replacement. The failure so far to influence tooth replacement in the zebrafish by perturbing Wnt signaling is discussed in the light of (i) potential technical pitfalls related to dose- or time-dependency, (ii) the complexity of the canonical Wnt pathway, and (iii) species-specific differences in the nature and activity of pathway components. Finally, we emphasize the importance of in-depth knowledge of the wild-type pattern for reliable interpretations. It is hoped that our analysis can be inspiring to critically assess and elucidate the role of Wnt signaling in tooth development in polyphyodonts. PMID

  16. The role of lumbar disc replacement in the surgical management of low back pain.

    PubMed

    Freeman, Brian J C

    2012-01-01

    Spinal fusion has long been the standard surgical treatment for degenerative disorders of the spine, but clinical outcomes are often unpredictable. Lumbar disc replacement allows removal of the pain source while preserving motion. This article explores the role of lumbar disc replacement in the surgical management of low back pain.

  17. Kinematics of total facet replacement (TFAS-TL) with total disc replacement

    PubMed Central

    Voronov, Leonard I.; Havey, Robert M.; Sjovold, Simon G.; Funk, Michael; Carandang, Gerard; Zindrick, Daniel; Rosler, David M.; Patwardhan, Avinash G.

    2009-01-01

    Background Total disc replacement (TDR) and total facet replacement (TFR) have been the focus of recent kinematics evaluations. Yet their concurrent function as a total joint replacement of the lumbar spine's 3-joint complex has not been comprehensively reported. This study evaluated the effect of a TFR specifically designed to replace the natural facets and supplement the function with the natural disc and with TDR. The ability to replace degenerated facets to complement a pre-existing or simultaneously implanted TDR may allow surgeons to completely address degenerative pathologies of the 3-joint complex of the lumbar spine. We hypothesized that TFR would reproduce the biomechanical function of the natural facets when implanted in conjunction with TDR. Methods Lumbar spines (L1-5, 51.3 ± 14.2 years, N = 6) were tested sequentially as follows: (1) intact, (2) after TDR implantation, and (3) after TFR implantation in conjunction with TDR, all at L3-4. Specimens were tested in flexion-extension (+ 8 Nm to − 6 Nm), lateral bending (± 6 Nm), and axial rotation (± 5 Nm). A 400 N compressive follower preload was applied during flexion-extension tests. Three-dimensional segmental motion was recorded and analyzed using analysis of variance in Systat (Systat Software Inc., Chicago, Illinois) and multiple comparisons with Bonferroni correction. Results The TDR implantation (TDR + natural facets) allowed similar lateral bending (P = .66), but it generally increased flexion-extension (P = .06) and axial rotation (P < .05) range of motion (ROM) at the implanted level compared to intact. The TFR + TDR (following replacement of the natural facets with TFR) decreased ROM to levels similar to intact in lateral bending (P = .70) and axial rotation (P = .23). The TFR + TDR flexion-extension ROM was reduced in comparison to intact and TDR + natural facets (P < .05). Conclusions The TFR with TDR was able to restore stability to the lumbar segment after bilateral facetectomy, while

  18. Disc replacement using Pro-Disc C versus fusion: a prospective randomised and controlled radiographic and clinical study

    PubMed Central

    Ahlhelm, F.; Pitzen, T.; Steudel, W. I.; Jung, J.; Shariat, K.; Steimer, O.; Bachelier, F.; Pape, D.

    2006-01-01

    Anterior cervical discectomy and fusion (ACDF) may be considered to be the gold standard for treatment of symptomatic degenerative disc disease within the cervical spine. However, fusion of the segment may result in progressive degeneration of the adjacent segments. Therefore, dynamic stabilization procedures have been introduced. Among these, artificial disc replacement by disc prosthesis seems to be promising. However, to be so, segmental motion must be preserved. This, again, is very difficult to judge and has not yet been proven. The aim of the current study was to first analyse the segmental motion following artificial disc replacement using a disc prosthesis. A second aim was to compare both segmental motion as well as clinical result to the current gold standard (ACDF). This is a prospective controlled study. Twenty-five patients with cervical disc herniation were enrolled and assigned to either study group (receiving a disc prosthesis) or control group (receiving ACDF, using a cage with bone graft and an anterior plate.) Radiostereometric analysis was used to quantify intervertebral motion immediately as well as 3, 6, 12 and 24 weeks postoperatively. Further, clinical results were judged using visual analogue scale and neuro-examination. Cervical spine segmental motion decreased over time in the presence of disc prosthesis or ACDF. However, the loss of segmental motion is significantly higher in the ACDF group, when looked at 3, 6, 12 and 24 weeks after surgery. We observed significant pain reduction in neck and arm postoperatively, without significant difference between both groups (P > 0.05). Cervical spine disc prosthesis preserves cervical spine segmental motion within the first 6 months after surgery. The clinical results are the same when compared to the early results following ACDF. PMID:17106665

  19. Changes in flexion-relaxation phenomenon and lumbo-pelvic kinematics following lumbar disc replacement surgery

    PubMed Central

    2013-01-01

    Background A single group prospective study. Disc prostheses are believed to contribute to the restoration of the segmental movement and the preservation of the adjacent segments. The study’s main objective was to determine if changes in neuromuscular patterns assessed using the flexion-relaxation phenomenon (FRP) can be observed following disc replacement surgery. Methods Fifteen subjects participated in this study; they were evaluated before and after lumbar disc replacement surgery. Both assessments included ten repetitions of a trunk flexion and extension movement (with and without a load), where the surface electromyography (EMG) and kinematic data were recorded. Results Following the disc replacement procedure (17.3 weeks ± 8.4), participants reported a significant reduction in their ODI and FABQ - physical activity scores. Increases in pelvic flexion as well as in erector spinae (ES) muscle activity at L5 in the flexion phase were observed. Following the disc replacement surgery, ES activity at L2 decreased during the quiet standing position. Conclusion The results of this study suggest that although improvements in disability scores and fear-avoidance related to physical activities scores were noted after a disc replacement surgery, the lumbar ROM was not modified. Nevertheless, a significant increase in the hip ROM during the flexion-extension task as well as an increase in ES muscle activity in flexion was observed following surgery. The VAS, FABQ I and ODQ scores were positively correlated with change in the muscular activities during the FRP. PMID:23842284

  20. A prospective morphological study of facet joint integrity following intervertebral disc replacement with the CHARITE Artificial Disc.

    PubMed

    Trouillier, Hans; Kern, P; Refior, H J; Müller-Gerbl, M

    2006-02-01

    In degenerative disc disease (DDD), increased loading in the posterior column increases facet joint subchondral bone density and may lead to facet joint degeneration. While spinal fusion is commonly used to treat patients with symptomatic DDD, increased stress at the levels adjacent to fusion may accelerate facet joint and adjacent segment degeneration. Artificial disc replacements have been developed as an alternative to fusion. In this prospective study, the effects of disc replacement with the CHARITE Artificial Disc on facet joint loading and integrity were evaluated. Thirteen patients aged <50 years with symptomatic DDD were recruited. Computed tomography (CT) osteoabsorptiometry was performed prior to the implantation of the CHARITE Artificial Disc and six months after. With this technique, increases or decreases in facet joint loading and integrity are indicated by corresponding changes in subchondral bone density. Changes in the distribution of load alter the distribution of the areas of maximum bone density. Clinical outcome was also assessed at pre-operative and 6 and 12 month post-operative visits using the Visual Analogue Scale back and leg pain scores, the Oswestry Disability Index and the Short Form-36 (SF-36) questionnaire. The height of the intervertebral space at the operated level was monitored by lateral X-ray. Subchondral bone density was evaluated in the facet joints of all 13 patients at the operated level, 12 patients at the level above the operated segment, and five patients at the level below the operated segment. Quantitative measurements revealed no significant increases (> or =3%) in subchondral bone density of the facet joints at any level in any patient. Significant decreases (> or =3%) in subchondral bone density were measured at the operated level in 10/13 patients, at the level above the operated segment in 6/12 patients, and at the level below the operated segment in 3/5 patients. There were no changes in the distribution of the

  1. Translation of an engineered nanofibrous disc-like angle-ply structure for intervertebral disc replacement in a small animal model.

    PubMed

    Martin, John T; Milby, Andrew H; Chiaro, Joseph A; Kim, Dong Hwa; Hebela, Nader M; Smith, Lachlan J; Elliott, Dawn M; Mauck, Robert L

    2014-06-01

    Intervertebral disc degeneration has been implicated in the etiology of low back pain; however, the current surgical strategies for treating symptomatic disc disease are limited. A variety of materials have been developed to replace disc components, including the nucleus pulposus (NP), the annulus fibrosus (AF) and their combination into disc-like engineered constructs. We have previously shown that layers of electrospun poly(ε-caprolactone) scaffold, mimicking the hierarchical organization of the native AF, can achieve functional parity with native tissue. Likewise, we have combined these structures with cell-seeded hydrogels (as an NP replacement) to form disc-like angle-ply structures (DAPS). The objective of this study was to develop a model for the evaluation of DAPS in vivo. Through a series of studies, we developed a surgical approach to replace the rat caudal disc with an acellular DAPS and then stabilized the motion segment via external fixation. We then optimized cell infiltration into DAPS by including sacrificial poly(ethylene oxide) layers interspersed throughout the angle-ply structure. Our findings illustrate that DAPS are stable in the caudal spine, are infiltrated by cells from the peri-implant space and that infiltration is expedited by providing additional routes for cell migration. These findings establish a new in vivo platform in which to evaluate and optimize the design of functional disc replacements.

  2. Effect of lubricants on friction in laboratory tests of a total disc replacement device.

    PubMed

    Moghadas, Parshia; Mahomed, Aziza; Hukins, David W L; Shepherd, Duncan E T

    2013-09-01

    Some designs of total disc replacement devices have articulating bearing surfaces, and these devices are tested in vitro with a lubricant of diluted calf serum. It is believed that the lubricant found in total disc replacement devices in vivo is interstitial fluid that may have properties between that in Ringer's solution and diluted calf serum. To investigate the effect of lubricants, a set of friction tests were performed on a generic model of a metal against metal ball-and-socket total disc replacement device. Two devices were tested: one with a ball radius of 10 mm and other with a ball radius of 16 mm; each device had a radial clearance of 0.015 mm. A spine simulator was used to measure frictional torque for each device in axial rotation, flexion-extension and lateral bending at frequencies of 0.25-2 Hz, under 1200 N axial load. Each device was tested with two different lubricants: a solution of new born calf serum diluted with deionised water and Ringer's solution. The results showed that the frictional torque generated between the bearing surfaces was significantly higher in Ringer's solution than in diluted calf serum. The use of Ringer's solution as a lubricant provides a stringent test condition to detect possible problems. Diluted calf serum is more likely to provide an environment closer to that in vivo. However, the precise properties of the fluid lubricating a total disc replacement device are not known; hence, tests using diluted calf serum may not necessarily give the same results as those obtained in vivo.

  3. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device.

    PubMed

    Coogan, Jessica S; Francis, W Loren; Eliason, Travis D; Bredbenner, Todd L; Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A; Nicolella, Daniel P

    2016-01-01

    Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the

  4. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

    PubMed Central

    Coogan, Jessica S.; Francis, W. Loren; Eliason, Travis D.; Bredbenner, Todd L.; Stemper, Brian D.; Yoganandan, Narayan; Pintar, Frank A.; Nicolella, Daniel P.

    2016-01-01

    Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3–L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3–L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with

  5. Total ankle replacement using HINTEGRA, an unconstrained, three-component system: surgical technique and pitfalls.

    PubMed

    Barg, Alexej; Knupp, Markus; Henninger, Heath B; Zwicky, Lukas; Hintermann, Beat

    2012-12-01

    Total ankle replacement (TAR) has become a valuable treatment option in patients with end-stage ankle osteoarthritis. One popular 3-component system, the HINTEGRA TAR, is an unconstrained system that provides inversion-eversion stability. More natural biomechanics of the replaced ankle may be expected when anatomic considerations drive prosthesis design. The HINTEGRA prosthesis includes 2 anatomically contoured metal components and a polyethylene insert, providing axial rotation and physiologic flexion-extension mobility. This article describes the HINTEGRA TAR design and surgical technique. Use of the prosthesis for complex hindfoot reconstruction in patients with an osteoarthritic, varus, or valgus ankle deformity is described.

  6. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery

    PubMed Central

    2010-01-01

    Background Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians’ training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. Findings A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a

  7. Cardiac pathology after valve replacement by disc prosthesis. A study of 61 necropsy patients.

    PubMed

    Roberts, W C; Fishbein, M C; Golden, A

    1975-05-01

    Clinical and necropsy observations are described in 61 patients who had one or more cardiac valves replaced with a discoid prosthesis of the Hufnagel type. The most common (31 percent) cause of death among the 45 patients who died early (less than 65 days after operation) appeared to be prosthetic disproportion; that is, the prothesis was too big for the aorta or ventricular cavity into which it was inserted so that inadequate space was present between the margins of the disc and the endocardium of ventricle or intima of aorta. Prosthetic thrombosis occurred in only 3 of the 45 patients who died early, but poppet movement appeared considerably altered in each. In contrast, thrombi were observed on a prosthesis in 14 of the 16 patients who died late (4 to 47 months [average 21] postoperatively), but in none did the thrombi appear of sufficient size to alter poppet function. Escessive bleeding occurred in 11 (24 percent) of the 45 early deaths and was primarily related to the insertion of a patch in the root of the aorta. Uncorrected valvular disease either by itself or by its ability to alter function of the prosthesis appeared responsible for death in 6 (13 percent) of the 45 patients who died early and in 2 (6 percent) of the 16 who died late. Insertion of a mitral poppet disc in a patient with uncorrected aortic regurgitation, even of mild degree, may be hazardous because the aortic regurgitant jet stream may interfere with proper function of the mitral disc. Likewise, insertion of a poppet disc only in the aortic valve position in a patient with combined aortic and mitral regurgitation may considerably increase the degree of mitral incompetence because the aortic prosthesis is intrinsically obstructive. Disc wear or variance was observed in all but one prosthesis in place for more than 1 year. Although hemolytic anemia of significant degree was not observed in any of the 16 patients who died late, the occurrence of renal hemosiderosis in 13 of the 16 patients

  8. Androgen deficiency in older men: indications, advantages, and pitfalls of testosterone replacement therapy.

    PubMed

    McGill, John J; Shoskes, Daniel A; Sabanegh, Edmund S

    2012-11-01

    The decline in testosterone with age has been associated with specific physical changes that affect quality of life and life expectancy, although a cause-and-effect relationship is yet to be established. While female menopause is rapid and well described, "male menopause" or androgen decline in older men is gradual and marked by nonspecific symptoms. This makes diagnosis of true testosterone deficiency and prediction of response to testosterone replacement therapy (TRT) challenging. This article reviews androgen decline in men, focusing on those over age 40, and covers symptoms, indications, contraindications,diagnosis, treatments, and the risks and benefits of treatment [corrected].

  9. Total disc replacement in the cervical spine: a systematic review evaluating long-term safety

    PubMed Central

    Anderson, Paul A.; Hashimoto, Robin

    2012-01-01

    Study design: Systematic review. Clinical questions: What are the rates and causes of subsequent surgeries? What is the long-term complication rates following cervical artificial disc replacement (C-ADR)? How do these rates change over time? Methods: A systematic review was undertaken for articles published up to October 2011. Electronic databases and reference lists of key articles were searched to identify comparative and non-comparative studies reporting long-term (≥ 48 months) complications of C-ADR. Two independent reviewers assessed the strength of evidence using the GRADE criteria and disagreements were resolved by consensus. Results: Two RCTs reporting outcomes following C-ADR (Bryan disc, Prestige disc) versus anterior cervical discectomy and fusion (ACDF) at follow-ups of 4 to 5 years were found; five case series reporting outcomes following C-ADR at follow-ups of 4 to 8 years were identified. Secondary surgery rates were similar or slightly lower following C-ADR compared with fusion at 4 to 5 years postoperatively. In one small subset of an RCT, rates of adjacent disc heterotopic ossification were lower in C-ADR patients than in those treated with fusion. Rates of other adverse events were similar between treatment groups. Conclusions: There is low evidence on the long-term safety outcomes following C-ADR. Additional comparative studies with follow-up of at least 4 years are needed to fully understand the long-term safety outcomes of C-ADR compared with fusion. PMID:23236309

  10. The Role of Posterior Longitudinal Ligament in Cervical Disc Replacement: An Ovine Cadaveric Biomechanical Analysis

    PubMed Central

    Yu, Cheng-Cheng; Hao, Ding-Jun; Ma, Yu-Li; Huang, Da-Geng; Li, Hou-Kun; Feng, Hang; Hou, Qian

    2016-01-01

    Background Cervical disc replacement (CDR) has been widely used to restore and maintain mobility and function of the treated and adjacent motion segments. Posterior longitudinal ligament (PLL) resection has been shown to be efficient in anterior cervical decompression and fusion. However, less is known about the biomechanical effect of PLL removal versus preservation in cervical disc arthroplasty. Material/Methods Three motion segments of 24 ovine cervical spines (C2–C5) were evaluated in a robotic spine system with axial compressive loads of 50 N. These cervical spines were divided in three groups according to the following conditions: (1) intact spine, (2) C3/C4 CDR with the Prestige LP prosthesis and PLL preservation, and (3) C3/C4 CDR with the Prestige LP prosthesis and PLL removal. The ranges of motion (ROMs) were recorded and analyzed in each group. Results The C3/C4 ROM in group 3 (CDR with PLL removed) increased significantly in flexion-extension and axial rotation compared with group 1 (intact spine). Moreover, in flexion-extension, the mean total ROM was significantly larger in group 3 than in group 1. All the ROM observed in group 2 (CDR with PLL preserved) did not significantly differ from the ROM observed in group 1. Conclusions Compared with intact spines, CDR with PLL removal partly increased ROM. Moreover, the ROM in CDR with PLL preservation did not significantly differ from the ROM observed in intact spines. The PLL appears to contribute to the balance and stability of the cervical spine and should thus be preserved in cervical disc replacement provided that the posterior longitudinal ligament is not degenerative and the compression can be removed without PLL takedown. PMID:27243444

  11. Severe Impingement of Lumbar Disc Replacements Increases the Functional Biological Activity of Polyethylene Wear Debris

    PubMed Central

    Baxter, Ryan M.; MacDonald, Daniel W.; Kurtz, Steven M.; Steinbeck, Marla J.

    2013-01-01

    Background: Wear, oxidation, and particularly rim impingement damage of ultra-high molecular weight polyethylene total disc replacement components have been observed following surgical revision. However, neither in vitro testing nor retrieval-based evidence has shown the effect(s) of impingement on the characteristics of polyethylene wear debris. Thus, we sought to determine (1) differences in polyethylene particle size, shape, number, or biological activity that correspond to mild or severe rim impingement and (2) in an analysis of all total disc replacements, regardless of impingement classification, whether there are correlations between the extent of regional damage and the characteristics of polyethylene wear debris. Methods: The extent of dome and rim damage was characterized for eleven retrieved polyethylene cores obtained at revision surgery after an average duration of implantation of 9.7 years (range, 4.6 to 16.1 years). Polyethylene wear debris was isolated from periprosthetic tissues with use of nitric acid and was imaged with use of environmental scanning electron microscopy. Subsequently, particle size, shape, number, biological activity, and chronic inflammation scores were determined. Results: Grouping of particles by size ranges that represented high biological relevance (<0.1 to 1-μm particles), intermediate biological relevance (1 to 10-μm particles), and low biological relevance (>10-μm particles) revealed an increased volume fraction of particles in the <0.1 to 1-μm and 1 to 10-μm size ranges in the mild-impingement cohort as compared with the severe-impingement cohort. The increased volume fractions resulted in a higher specific biological activity per unit particle volume in the mild-impingement cohort than in the severe-impingement cohort. However, functional biological activity, which is normalized by particle volume (mm3/g of tissue), was significantly higher in the severe-impingement cohort. This increase was due to a larger volume

  12. Artificial total disc replacement versus fusion for the cervical spine: a systematic review

    PubMed Central

    Winkler, Roman; Mad, Philipp

    2010-01-01

    Cervical total disc replacement (CTDR) has been increasingly used as an alternative to fusion surgery in patients with pain or neurological symptoms in the cervical spine who do not respond to non-surgical treatment. A systematic literature review has been conducted to evaluate whether CTDR is more efficacious and safer than fusion or non-surgical treatment. Published evidence up to date is summarised qualitatively according to the GRADE methodology. After 2 years of follow-up, studies demonstrated statistically significant non-inferiority of CTDR versus fusion with respect to the composite outcome ‘overall success’. Single patient relevant endpoints such as pain, disability or quality of life improved in both groups with no superiority of CTDR. Both technologies showed similar complication rates. No evidence is available for the comparison between CTDR and non-surgical treatment. In the long run improvement of health outcomes seems to be similar in CTDR and fusion, however, the study quality is often severely limited. After both interventions, many patients still face problems. A difficulty per se is the correct diagnosis and indication for surgical interventions in the cervical spine. CTDR is no better than fusion in alleviating symptoms related to disc degeneration in the cervical spine. In the context of limited resources, a net cost comparison may be sensible. So far, CTDR is not recommended for routine use. As many trials are ongoing, re-evaluation at a later date will be required. Future research needs to address the relative effectiveness between CTDR and conservative treatment. PMID:20936484

  13. Radiographic total disc replacement angle measurement accuracy using the Oxford Cobbometer: precision and bias

    PubMed Central

    Stafylas, Kosmas; McManus, John; Schizas, Constantin

    2008-01-01

    Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4–L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4° between readings at any individual position, and as high as 6° between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs. PMID:18496719

  14. Anhidrosis after anterior retroperitoneal approach for L4-L5 artificial disc replacement.

    PubMed

    Kasliwal, Manish K; Deutsch, Harel

    2011-07-01

    Description of injury to the sympathetic nervous system after the anterior approach to the lumbosacral spine remains restricted to reports of retrograde ejaculation in males occurring in 2% to 20% of patients. The authors describe a 46-year-old female who presented with low back pain for several years due to degenerative disk disease at L4-L5 that had been treated with an L4-L5 artificial disc replacement though a left anterior retroperitoneal approach. She has had an excellent outcome with complete resolution of her back pain, but noticed the development of dryness of her left lower limb with anhidrosis and skin breakdown, which has caused persistent discomfort. The complication had persisted at her 1-year follow up. Damage to the sympathetic system may often go unrecognized but present with subtle symptoms, as described in the present report. Sympathetic injury in women is often not addressed and remains unrecognized except for a few reports of vaginal dryness or anaesthesia. A short description of this unusual and underappreciated complication, which may be a cause of discomfort despite successful surgery, is presented.

  15. Indications for Lumbar Total Disc Replacement: Selecting the Right Patient with the Right Indication for the Right Total Disc

    PubMed Central

    Guyer, Richard D.; Ohnmeiss, Donna D.

    2014-01-01

    Summary of Background Data As with any surgery, care should be taken to determine patient selection criteria for lumbar TDR based on safety and optimizing outcome. These goals may initially be addressed by analyzing biomechanical implant function and early clinical experience, ongoing evaluation is needed to refine indications. Objective The purpose of this work was to synthesize information published on general indications for lumbar TDR. A secondary objective was to determine if indications vary for different TDR designs. Methods A comprehensive literature search was conducted to identify lumbar TDR articles. Articles were reviewed and patient selection criteria and indications were synthesized. Results With respect to safety, there was good agreement in the literature to exclude patients with osteopenia/osteoporosis or fracture. Risk of injury to vascular structures due to the anterior approach was often addressed by excluding patients with previous abdominal surgery in the area of disc pathology or increased age. The literature was very consistent on the primary indication for TDR being painful disc degeneration unresponsive to at least 6 months of nonoperative care. Literature investigating the impact of previous spine surgery was mixed; however, prior surgery was not necessarily a contra-indication, provided the patient otherwise met selection criteria. The literature was mixed on setting a minimum preoperative disc height as a selection criterion. There were no publications investigating whether some patients are better/worse candidates for specific TDR designs. Based on the literature a proposal for patient selection criteria is offered. Conclusions Several TDR indications and contra-indications are widely accepted. No literature addresses particular TDR design being preferable for some patients. As with any spine surgery, ongoing evaluation of TDR outcomes will likely lead to more detailed general and device design specific indications. PMID:25694946

  16. Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance

    PubMed Central

    Wiechert, Karsten; Khattab, Mohamed F.; Korge, Andreas; Mayer, H. Michael

    2007-01-01

    Despite the increasing popularity of total lumbar disc replacement (TDR) in predominantly young and active patients, no previous study has addressed possibilities, limitations and potential risks regarding athletic performance following TDR. Mechanical concerns remain and the implant’s resilience as regards its load-bearing capacity during sporting activities is unknown. Thirty-nine athletic patients fulfilled the inclusion criteria for this study. These patients participated in a large variety of different types of sport. Significant and lasting pain-relief was attained following TDR with a mean follow-up of 26.3 months (range 9–50.7 months; FU rate 97.4%). Sporting activity was resumed within the first 3 months (38.5%) to 6 months (30.7%) with peak performance being reached after 5.2 months. Thirty-seven patients (94.9%) achieved resumption of sporting activity. Athletic performance improved significantly in 33 patients (84.6%). Minor subsidence was observed in 13 patients (30%) within the first 3 months with no further implant migration thereafter in 12 patients. Participation in all types of sport recorded in this study was accessible for a high rate of patients up to the level of professional athletes as well as those participating in extreme sports. Preoperative participation in sport proved to be a strong positive predictor for highly satisfactory postoperative outcome following TDR. In a selected group of patients, however, preoperative inability to participate in sporting activities did not impair postoperative physical activity. Due to the young age of the patients and significant load increase exerted during athletic activities, persisting concerns regarding the future behaviour of the implant remain and will require longer follow-up, modified investigation techniques and larger patient cohorts. PMID:17205239

  17. Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance.

    PubMed

    Siepe, Christoph J; Wiechert, Karsten; Khattab, Mohamed F; Korge, Andreas; Mayer, H Michael

    2007-07-01

    Despite the increasing popularity of total lumbar disc replacement (TDR) in predominantly young and active patients, no previous study has addressed possibilities, limitations and potential risks regarding athletic performance following TDR. Mechanical concerns remain and the implant's resilience as regards its load-bearing capacity during sporting activities is unknown. Thirty-nine athletic patients fulfilled the inclusion criteria for this study. These patients participated in a large variety of different types of sport. Significant and lasting pain-relief was attained following TDR with a mean follow-up of 26.3 months (range 9-50.7 months; FU rate 97.4%). Sporting activity was resumed within the first 3 months (38.5%) to 6 months (30.7%) with peak performance being reached after 5.2 months. Thirty-seven patients (94.9%) achieved resumption of sporting activity. Athletic performance improved significantly in 33 patients (84.6%). Minor subsidence was observed in 13 patients (30%) within the first 3 months with no further implant migration thereafter in 12 patients. Participation in all types of sport recorded in this study was accessible for a high rate of patients up to the level of professional athletes as well as those participating in extreme sports. Preoperative participation in sport proved to be a strong positive predictor for highly satisfactory postoperative outcome following TDR. In a selected group of patients, however, preoperative inability to participate in sporting activities did not impair postoperative physical activity. Due to the young age of the patients and significant load increase exerted during athletic activities, persisting concerns regarding the future behaviour of the implant remain and will require longer follow-up, modified investigation techniques and larger patient cohorts.

  18. Biomechanical Analysis of a Novel Prosthesis Based on the Physiological Curvature of Endplate for Cervical Disc Replacement

    PubMed Central

    Yu, Cheng-Cheng; Hao, Ding-Jun; Huang, Da-Geng; Qian, Li-Xiong; Feng, Hang; Li, Hou-Kun; Zhao, Song-Chuan

    2016-01-01

    Study Design Biomechanical analysis of a novel prosthesis based on the physiological curvature of endplate was performed. Objective To compare the biomechanical differences between a novel prosthesis based on the physiological curvature of the endplate and the Prestige LP prosthesis after cervical disc replacement (CDR). Summary of Background Data Artificial disc prostheses have been widely used to preserve the physiological function of treated and adjacent motion segments in CDR, while most of those present a flat surface instead of an arcuate surface which approximately similar to anatomic structures in vivo. We first reported a well-designed artificial disc prosthesis based on the physiological curvature of the endplate. Methods Three motion segments of 24 ovine cervical spines (C2-5) were evaluated in a robotic spine system with axial compressive loads of 50N. Testing conditions were as follows: 1) intact, 2) C3–4 CDR with artificial disc prosthesis based on the physiological curvature of the endplate, and 3) C3–4 CDR with the Prestige LP prosthesis. The range of motion (ROM) and the pressures on the inferior surface of the two prostheses were recorded and analyzed. Results As compared to the intact state, the ROM of all three segments had no significant difference in the replacement group. Additionally, there was no significant difference in ROM between the two prostheses. The mean pressure on the novel prosthesis was significantly less than the Prestige LP prosthesis. Conclusion ROM in 3 groups (intact group, CDR group with novel prosthesis and CDR group with Prestige LP) showed no significant difference. The mean pressure on the inferior surface of the novel prosthesis was significantly lower than the Prestige LP prosthesis. Therefore, the novel artificial disc prosthesis is feasible and effective, and can reduce the implant-bone interface pressure on the endplate, which may be one possible reason of prosthesis subsidence. PMID:27355319

  19. Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation

    PubMed Central

    Liao, Zhenhua; Fogel, Guy R.; Pu, Ting; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF). Material/Methods Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P). Results Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p<0.05). 3DPD construct resulted in slight increase at the 3 instrumented levels (p>0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (p<0.05). Both 3DPD and 3PDP caused significant reduction of ROM at the arthrodesis level and produced motion increase at the arthroplasty level. For adjacent levels, 3P resulted in markedly increased contribution of both upper and lower adjacent levels (p<0.05). Significant motion increases lower than 3P were only noted at partly adjacent levels in some conditions for 3DPD and 3PDP (p<0.05). Conclusions ACDF eliminated motion within the construct and greatly increased adjacent motion. Artificial cervical disc replacement normalized motion of its segment and adjacent segments. While hybrid conditions failed to restore normal motion within the construct, they significantly normalized motion in adjacent segments compared with the 3-level ACDF condition. The artificial disc in 3-level constructs has biomechanical advantages compared to fusion in normalizing motion. PMID:26529430

  20. A Broken Drill-bit Fragment Causing Severe Radiating Pain after Cervical Total Disc Replacement: A Case Report.

    PubMed

    Lee, Chong-Suh; Chung, Sung-Soo; Park, Jae-Chul; Shin, Seong-Kee; Park, Yong-Serk; Kang, Kyung-Chung

    2011-06-01

    This is a case report of a 38-year-old man with severe radiating pain on upper extremity after cervical total disc replacement (TDR). We faced an unusual complication that has not been reported yet. He underwent cervical TDR for left central disc protrusion on C5-6. After the surgery, preoperative symptom disappeared. However, at postoperative 1 year, he complained severe right-sided radiating pain that had a sudden onset. On postoperative X-ray, a metal fragment which seemed like a broken drill bit was shown within the spinal canal. To remove that, right-sided anterior microforaminotomy on C5-6 was performed and the metal fragment was removed successfully. After that, anterior fusion was done because the motion of the artificial disc was minimal and the removed structure seemed to attenuate stability during cervical motion. The operation resulted in prompt symptomatic relief. During cervical TDR, particular attention should be paid to the procedures that require using drill-bits.

  1. Harken Caged-Disc Mitral Valve Replacement, 1969-1975: Analysis of Late Mortality, Thromboembolism, and Valve Failure

    PubMed Central

    Gray, Richard J.; Czer, Lawrence S.C.; Chaux, Aurelio; Sethna, Dhun; Derobertis, Michele; Raymond, Marjorie; Matloff, Jack M.

    1987-01-01

    We evaluated the long-term outcome of mitral valve replacement with a Harken caged-disc prosthesis for up to 11 years (range, 50 to 130 months; mean, 81 months) in 170 patients whose mean age was 55 years. The early (30-day) mortality was 11.2% (19 out of 170 patients). Late follow-up information was obtained for 144 (95%) of the 151 survivors. The actuarial survival was 57% at 5 years and 40% at 10 years. Overall mortality was associated with advanced age, male sex, an ischemic origin for the mitral valve disease, and nonuse of warfarin anticoagulation. Late deaths (n=59) were valve-related in 46%, cardiac but non-valve-related in 44%, and noncardiac in 10% of the cases. One thromboembolic event or more occurred in 41 patients (incidence, 5.7% per patient year), 14 of whom died (24% of the late deaths). All four patients who were not on warfarin, aspirin, or other antithrombotic therapy experienced thromboemboli. This complication was correlated with the nonuse of warfarin-type anticoagulation, with mitral regurgitation, and with late cardiac death. Mechanical prosthetic failure resulted in reoperation or death in 7.6% of the late survivors (1.5% per patient year). In 75 patients with normally functioning prostheses, the disc-to-sewing ring ratio was established by means of cinefluoroscopy (0.93 ± 0.04, mean ± 25D). Because of the high proportion of cardiac valve-related deaths (46%), the high incidence of late mortality due to thromboembolic events (24%), and the 7.6% incidence of reoperation or death resulting from mechanical valve failure, close follow-up with cinefluoroscopy and continued warfarin anticoagulation (alone or in combination with dipyridamole) are essential after mitral valve replacement with the Harken caged-disc prosthesis. (Texas Heart Institute Journal 1987; 14:411-417) Images PMID:15227298

  2. Cervical Total Disc Replacement is Superior to Anterior Cervical Decompression and Fusion: A Meta-Analysis of Prospective Randomized Controlled Trials

    PubMed Central

    Zhang, Yujie; Liang, Chengzhen; Tao, Yiqing; Zhou, Xiaopeng; Li, Hao; Li, Fangcai; Chen, Qixin

    2015-01-01

    Background Despite being considered the standard surgical procedure for symptomatic cervical disc disease, anterior cervical decompression and fusion invariably accelerates adjacent segment degeneration. Cervical total disc replacement is a motion-preserving procedure developed as a substitute to fusion. Whether cervical total disc replacement is superior to fusion remains unclear. Methods We comprehensively searched PubMed, EMBASE, Medline, and the Cochrane Library in accordance with the inclusion criteria to identify possible studies. The retrieved results were last updated on December 12, 2014. We classified the studies as short-term and midterm follow-up. Results Nineteen randomized controlled trials involving 4516 cases were identified. Compared with anterior cervical decompression and fusion, cervical total disc replacement had better functional outcomes (neck disability index [NDI], NDI success, neurological success, neck pain scores reported on a numerical rating scale [NRS], visual analog scales scores and overall success), greater segmental motion at the index level, fewer adverse events and fewer secondary surgical procedures at the index and adjacent levels in short-term follow-up (P < 0.05). With midterm follow-up, the cervical total disc replacement group indicated superiority in the NDI, neurological success, pain assessment (NRS), and secondary surgical procedures at the index level (P < 0.05). The Short Form 36 (SF-36) and segmental motion at the adjacent level in the short-term follow-up showed no significant difference between the two procedures, as did the secondary surgical procedure rates at the adjacent level with midterm follow-up (P > 0.05). Conclusions Cervical total disc replacement presented favorable functional outcomes, fewer adverse events, and fewer secondary surgical procedures. The efficacy and safety of cervical total disc replacement are superior to those of fusion. Longer-term, multicenter studies are required for a better

  3. Positive Pitfalls

    ERIC Educational Resources Information Center

    Schneider, Michael

    2004-01-01

    This article describes how Cahokia middle and high school students conduct inquiry-based science through a pitfall trap experiment. In a collaborative effort, students designed and conducted pitfall trap investigations that combined their interest in the natural world with their love of technology. The students set up their own experiments to…

  4. Five-year clinical results of cervical total disc replacement compared with anterior discectomy and fusion for treatment of 2-level symptomatic degenerative disc disease: a prospective, randomized, controlled, multicenter investigational device exemption clinical trial.

    PubMed

    Radcliff, Kris; Coric, Domagoj; Albert, Todd

    2016-08-01

    OBJECTIVE The purpose of this study was to report the outcome of a study of 2-level cervical total disc replacement (Mobi-C) versus anterior cervical discectomy and fusion (ACDF). Although the long-term outcome of single-level disc replacement has been extensively described, there have not been previous reports of the 5-year outcome of 2-level cervical disc replacement. METHODS This study reports the 5-year results of a prospective, randomized US FDA investigational device exemption (IDE) study conducted at 24 centers in patients with 2-level, contiguous, cervical spondylosis. Clinical outcomes at up to 60 months were evaluated, including validated outcome measures, incidence of reoperation, and adverse events. The complete study data and methodology were critically reviewed by 3 independent surgeon authors without affiliation with the IDE study or financial or institutional bias toward the study sponsor. RESULTS A total of 225 patients received the Mobi-C cervical total disc replacement device and 105 patients received ACDF. The Mobi-C and ACDF follow-up rates were 90.7% and 86.7%, respectively (p = 0.39), at 60 months. There was significant improvement in all outcome scores relative to baseline at all time points. The Mobi-C patients had significantly more improvement than ACDF patients in terms of Neck Disability Index score, SF-12 Physical Component Summary, and overall satisfaction with treatment at 60 months. The reoperation rate was significantly lower with Mobi-C (4%) versus ACDF (16%). There were no significant differences in the adverse event rate between groups. CONCLUSIONS Both cervical total disc replacement and ACDF significantly improved general and disease-specific measures compared with baseline. However, there was significantly greater improvement in general and disease-specific outcome measures and a lower rate of reoperation in the 2-level disc replacement patients versus ACDF control patients. Clinical trial registration no. NCT00389597

  5. Clinical and radiologic comparison of dynamic cervical implant arthroplasty and cervical total disc replacement for single-level cervical degenerative disc disease.

    PubMed

    Shichang, Liu; Yueming, Song; Limin, Liu; Lei, Wang; Zhongjie, Zhou; Chunguang, Zhou; Xi, Yang

    2016-05-01

    Anterior cervical discectomy and fusion, to date the most successful spine procedure for the surgical treatment of cervical radiculopathy, has limitations that have led to the development of non-fusion cervical procedures, such as cervical total disc replacement (TDR) and dynamic cervical implant (DCI) arthroplasty. We compared the clinical and radiological results of DCI and cervical TDR for the treatment of single-level cervical degenerative disc disease in Chinese patients. A retrospective review of 179 patients with cervical spondylotic myelopathy who underwent DCI or TDR between April 2010 and October 2012 was conducted, and 152 consecutive patients (67 patients single-level DCI and 85 single-level TDR) who completed at least 2years of follow-up were included. Clinical and radiological assessments were performed preoperatively and at 1week and 3, 6, 12, and 24months postoperatively. The most common operative level was C5/C6 (49.3%). The differences in blood loss, duration of surgery, and duration of hospitalization were not statistically significant. The Japanese Orthopaedic Association scale, Visual Analog Scale, Neck Disability Index, and Short Form-36 scores improved significantly after surgery in both the DCI and TDR groups (P<0.05), but the differences were not statistically significant at the final follow-up. The rate of occurrence of heterotopic ossification was 22.4% and 28.2% in the DCI and TDR groups, respectively. As an effective non-fusion technique, DCI is a more economical procedure. Further prospective, randomized studies with long-term follow-up periods are needed to determine the long-term effects.

  6. Biomechanics of Artificial Disc Replacements Adjacent to a 2-Level Fusion in 4-Level Hybrid Constructs: An In Vitro Investigation

    PubMed Central

    Liao, Zhenhua; Fogel, Guy R.; Wei, Na; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal procedure for multilevel cervical degenerative disc diseases remains controversial. Recent studies on hybrid surgery combining anterior cervical discectomy and fusion (ACDF) and artificial cervical disc replacement (ACDR) for 2-level and 3-level constructs have been reported in the literature. The purpose of this study was to estimate the biomechanics of 3 kinds of 4-level hybrid constructs, which are more likely to be used clinically compared to 4-level arthrodesis. Material/Methods Eighteen human cadaveric spines (C2–T1) were evaluated in different testing conditions: intact, with 3 kinds of 4-level hybrid constructs (hybrid C3–4 ACDR+C4–6 ACDF+C6–7ACDR; hybrid C3–5ACDF+C5–6ACDR+C6–7ACDR; hybrid C3–4ACDR+C4–5ACDR+C5–7ACDF); and 4-level fusion. Results Four-level fusion resulted in significant decrease in the C3–C7 ROM compared with the intact spine. The 3 different 4-level hybrid treatment groups caused only slight change at the instrumented levels compared to intact except for flexion. At the adjacent levels, 4-level fusion resulted in significant increase of contribution of both upper and lower adjacent levels. However, for the 3 hybrid constructs, significant changes of motion increase far lower than 4P at adjacent levels were only noted in partial loading conditions. No destabilizing effect or hypermobility were observed in any 4-level hybrid construct. Conclusions Four-level fusion significantly eliminated motion within the construct and increased motion at the adjacent segments. For all 3 different 4-level hybrid constructs, ACDR normalized motion of the index segment and adjacent segments with no significant hypermobility. Compared with the 4-level ACDF condition, the artificial discs in 4-level hybrid constructs had biomechanical advantages compared to fusion in normalizing adjacent level motion. PMID:26694835

  7. In-situ photopolymerized and monitored implants: successful application to an intervertebral disc replacement

    NASA Astrophysics Data System (ADS)

    Schmocker, Andreas M.; Khoushabi, Azadeh; Bourban, Pierre-Etienne; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe

    2016-02-01

    Photopolymerization is a common method to harden materials initially in a liquid state. A surgeon can directly trigger the solidification of a dental implant or a bone or tissue filler by using ultra-violet light. Traditionally, photopolymerization has been used mainly in dentistry. Over the last decade advances in material development including a wide range of biocompatible gel- and cement-systems open up a new avenue for in-situ photopolymerization. We designed a miniaturized light probe where a photoactive material can be 1) mixed, pressurized and injected 2) photopolymerized or photoactivated and 3) monitored during the chemical reaction. The device enables surgeries to be conducted through a hole smaller than 500 μm in diameter. Using a combination of Raman and fluorescence spectroscopy, the current state of the photopolymerization was inferred and monitored in real time within an in-vitro tissue model. It was also possible to determine roughly the position of the probe within the tissue cavity by analysing the fluorescence signal. Using the technique hydrogels were successfully implanted into a bovine intervertebral disc model. Mechanical tests could not obstruct the functionality of the implant. Finally, the device was also used for other application such as the implantation of a hydrogel into an aneurysm tissue cavity which will be presented at the conference.

  8. Quality of systematic reviews: an example of studies comparing artificial disc replacement with fusion in the cervical spine.

    PubMed

    Tashani, Osama A; El-Tumi, Hanan; Aneiba, Khaled

    2015-01-01

    Cervical artificial disc replacement (C-ADR) is now an alternative to anterior cervical discectomy and fusion (ACDF). Many studies have evaluated the efficacy of C-ADR compared with ACDF. This led to a series of systematic reviews and meta-analyses to evaluate the evidence of the superiority of one intervention against the other. The aim of the study presented here was to evaluate the quality of these reviews and meta-analyses. Medline via Ovid, Embase, and Cochrane Library were searched using the keywords: (total disk replacement, prosthesis, implantation, discectomy, and arthroplasty) AND (cervical vertebrae, cervical spine, and spine) AND (systematic reviews, reviews, and meta-analysis). Screening and data extraction were conducted by two reviewers independently. Two reviewers then assessed the quality of the selected reviews and meta-analysis using 11-item AMSTAR score which is a validated measurement tool to assess the methodological quality of systematic reviews. Screening of full reports of 46 relevant abstracts resulted in the selection of 15 systematic reviews and/or meta-analyses as eligible for this study. The two reviewers' inter-rater agreement level was high as indicated by kappa of >0.72. The AMSTAR score of the reviews ranged from 3 to 11. Only one study (a Cochrane review) scored 100% (AMSTAR 11). Five studies scored below (AMSTAR 5) indicating low-quality reviews. The most significant drawbacks of reviews of a score below 5 were not using an extensive search strategy, failure to use the scientific quality of the included studies appropriately in formulating a conclusion, not assessing publication bias, and not reporting the excluded studies. With a significant exception of a Cochrane review, the methodological quality of systematic reviews evaluating the evidence of C-ADR versus ACDF has to be improved.

  9. Synthesis and characterization of injectable bioadhesive hydrogels for nucleus pulposus replacement and repair of the damaged intervertebral disc.

    PubMed

    Vernengo, J; Fussell, G W; Smith, N G; Lowman, A M

    2010-05-01

    Bioadhesive polymers are natural or synthetic materials that can be used for soft tissue repair. The aim of this investigation was to develop an injectable, bioadhesive hydrogel with the potential to serve as a synthetic replacement for the nucleus pulposus of the intervertebral disc or as an annulus closure material. Branched copolymers of poly(N-isopropylacrylamide) (PNIPAAm) and poly(ethylene glycol) (PEG) were blended with poly(ethylene imine) (PEI). This three component injectable system can form a precipitated gel at physiological temperature due to the phase transition of PNIPAAm. The injection of glutaraldehyde into the gel core will adhere the implant to the surrounding tissues. (1)H NMR results indicated the successful physical incorporation of PEI into the PNIPAAm-PEG network by blending. In addition, the covalent crosslinking between the amine functionalities on the PEI and the aldehyde functionalities on the glutaraldehyde was verified using FTIR difference spectroscopy. Mechanical characterization of these blends showed a significant increase (p < 0.05) in compressive modulus following glutaraldehyde injection. The in vitro bioadhesive force studies with porcine skin showed a significant increase (p < 0.05) in the mean maximum force of detachment for PNIPAAm-PEG/PEI gels when glutaraldehyde was injected into the gel core. The results of this study indicate that the reactivity between amines and aldehyde functionalities can be exploited to impart bioadhesive properties to PNIPAAm-PEG/PEI copolymers.

  10. The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements.

    PubMed

    Kurtz, Steven M; Toth, Jeffrey M; Siskey, Ryan; Ciccarelli, Lauren; Macdonald, Dan; Isaza, Jorge; Lanman, Todd; Punt, Ilona; Steinbeck, Marla; Goffin, Jan; van Ooij, André

    2012-03-01

    Knowledge regarding the in vivo performance and periposthetic tissue response of cervical and lumbar total disc replacements (TDRs) continues to expand. This review addresses the following four main questions: 1) What are the latest lessons learned from polyethylene in large joints and how are they relevant to current TDRs? 2) What are the latest lessons learned regarding adverse local tissue reactions from metal-on-metal, CoCr bearings in large joints and how are they relevant to current TDRs? 3) What advancements have been made in understanding the in vivo performance of alternative biomaterials, such as stainless steel and polycarbonate urethane, for TDRs in the past five years? 4) How has retrieval analysis of all these various artificial disc bearing technologies advanced the state of the art in preclinical testing of TDRs? The study of explanted artificial discs and their associated tissues can help inform bearing selection as well as the design of future generations of disc arthroplasty. Analyzing retrieved artificial discs is also essential for validating preclinical test methods.

  11. A case of cervical metastases in a patient with preexisting cervical disc replacement and fusion after 2-year symptom-free interval: when do we need interdisciplinary diagnostics?

    PubMed

    Melloh, Markus; Barz, Thomas

    2012-08-01

    Recurrent cervical symptoms frequently occur after cervical disc replacement and fusion. To date, no algorithm for the diagnostic assessment of these symptoms has been established. We present a case report and review of the literature to illustrate the need for interdisciplinary diagnostics in recurrent cervicobrachialgia without pathological cervical imaging. The hospital chart, medical history, physical examination, and imaging of a single patient were reviewed. A 53-year-old man with preexisting cervical disc replacement and fusion presented with a new episode of cervicobrachialgia after a 2-year symptom-free interval. Cervical magnetic resonance imaging (MRI) showed no pathological findings. Six months later the patient reported increasing symptoms including numbness and weakness of the right arm. Repeated cervical MRI and thoracic computed tomography revealed cervical metastases with intraspinal tumor growth and an underlying extensive small cell bronchial carcinoma. In recurrent cervicobrachialgia, without pathological cervical imaging, interdisciplinary diagnostics are needed. Basic diagnostic tests may assist to exclude severe non-vertebrogenic pathologies.

  12. Long term preservation of motion with artificial cervical disc implants: A comparison between cervical disc replacement and rigid fusion with cage

    PubMed Central

    Cincu, Rafael; Lorente, Francisco de Asis; Gomez, Joaquin; Eiras, Jose; Agrawal, Amit

    2014-01-01

    Background: With the advancement of technologies there is more interest in the maintenance of the spine's biomechanical properties focusing on the preservation of the functional motion segment. In present article we describe our experience with 25 cases managed with artificial cervical discs with 28 Solis cage following cervical discectomy with a mean follow-up period of 7.5 year. Materials and Methods: All surgeries were performed by single surgeon from March 2004 to June 2005 with a follow-up till date. Patients with symptomatic single or multiple level diseases that had no prior cervical surgery were candidates for the study. Cohort demographics were comparable. Standardized clinical outcome measures and radiographic examinations were used at prescribed post-operative intervals to compare the treatment groups. Relief in radicular pain, cervical spine motion, and degenerative changes at follow-up were noted. Results: In a total 53 cases, the mean age in prosthesis group was 47 years (age range: 30-63 years) and mean age in cage group was 44 years (32-62 years). Mean hospital stay was 2.7 days in both the groups. At 4 weeks complete cervical movements could be achieved in 19 cases in artificial disc group. Maintenance of movement after 7.5 years was in 76% of these patients. Lordosis was maintained in all cases till date. There was no mortality or wound infection in our series. Conclusions: We conclude that artificial cervical disc could be an alternative to fixed spinal fusion as it represents the most physiological substitute of disc. However, there is need for further studies to support the use of artificial cervical disc prosthesis. PMID:25685218

  13. Cervical artificial disc replacement versus fusion in the cervical spine: a systematic review comparing multilevel versus single-level surgery

    PubMed Central

    Kepler, Christopher K.; Brodt, Erika D.; Dettori, Joseph R.; Albert, Todd J.

    2012-01-01

    Study design: Systematic review. Clinical questions: What is the effectiveness of multilevel cervical artificial disc replacement (C-ADR) compared with multilevel fusion with respect to pain and functional outcomes, and are the two procedures comparable in terms of safety? What is the effectiveness of multilevel C-ADR compared with single-level C-ADR with respect to pain and functional outcomes, and are the two procedures comparable in terms of safety? Methods: A systematic review was undertaken for articles published up to October 2011. Electronic databases and reference lists of key articles were searched to identify studies comparing multilevel C-ADR with multilevel anterior cervical discectomy and fusion (ACDF) or comparing multilevel C-ADR with single-level C-ADR. Studies which compared these procedures in the lumbar or thoracic spine or that reported alignment outcomes only were excluded. Two independent reviewers assessed the strength of evidence using the GRADE criteria and disagreements were resolved by consensus. Results: Two studies compared multilevel C-ADR with multilevel ACDF. While both reported improved Neck Disability Index (NDI) and Short-Form 36 (SF-36) scores after C-ADR compared with ACDF, only one study reported statistically significant results. Seven studies compared single-level C-ADR with multilevel C-ADR. Results were similar in terms of overall success, NDI and SF-36 scores, and patient satisfaction. There is discrepant information regarding rates of heterotopic ossification; dysphagia rate may be higher in multilevel C-ADR. Conclusions: The literature suggests that outcomes are at least similar for multilevel C-ADR and ACDF and may favor C-ADR. Future studies are necessary before firm recommendations can be made favoring one treatment strategy. Multilevel C-ADR seems to have similar results to single-level C-ADR but may have higher rates of heterotopic ossification and dysphagia. PMID:23236310

  14. Artificial Disc Replacement

    MedlinePlus

    ... such as medication, injections, chiropractic care and/or physical therapy. Typically, you will have had an MRI that ... has gone through nonoperative treatments (such as active physical therapy, medication, injections, activity modification and/or spinal manipulation). ...

  15. The Mobi-C cervical disc for one-level and two-level cervical disc replacement: a review of the literature

    PubMed Central

    Alvin, Matthew D; Mroz, Thomas E

    2014-01-01

    Background Cervical disc arthroplasty (CDA) is a novel motion-preserving procedure that is an alternative to fusion. The Mobi-C disc prosthesis, one of many Food and Drug Administration (FDA)-approved devices for CDA, is the only FDA-approved prosthesis for two-level CDA. Hence, it may allow for improved outcomes compared with multilevel fusion procedures. Purpose To critically assess the available literature on CDA with the Mobi-C prosthesis, with a focus on two-level CDA. Methods All clinical articles involving the Mobi-C disc prosthesis for CDA through September 1, 2014 were identified on Medline. Any paper that presented Mobi-C CDA clinical results was included. Study design, sample size, length of follow-up, use of statistical analysis, quality of life outcome scores, conflict of interest, and complications were recorded. Results Fifteen studies were included that investigated Mobi-C CDA, only one of which was a level Ib randomized control trial. All studies included showed non-inferiority of one-level Mobi-C CDA to one-level anterior cervical discectomy and fusion (ACDF). Only one study analyzed outcomes of one-level versus two-level Mobi-C CDA, and only one study analyzed two-level Mobi-C CDA versus two-level ACDF. In comparison with other cervical disc prostheses, the Mobi-C prosthesis is associated with higher rates of heterotopic ossification (HO). Studies with conflicts of interest reported lower rates of HO. Adjacent segment degeneration or disease, along with other complications, were not assessed in most studies. Conclusion One-level Mobi-C CDA is non-inferior, but not superior, to one-level ACDF for patients with cervical degenerative disc disease. The Mobi-C CDA procedure is associated with high rates of HO. Two-level Mobi-C CDA may be superior to two-level ACDF. However, insufficient evidence exists, thereby mandating a need for unbiased, well-designed prospective studies with well-defined outcomes in the future. PMID:25473319

  16. Total disc replacement compared to lumbar fusion: a randomised controlled trial with 2-year follow-up

    PubMed Central

    Tullberg, Tycho; Branth, Björn; Olerud, Claes; Tropp, Hans

    2009-01-01

    The study design includes a prospective, randomised controlled study comparing total disc replacement (TDR) with posterior fusion. The main objective of this study is to compare TDR with lumbar spinal fusion, in terms of clinical outcome, in patients referred to a spine clinic for surgical evaluation. Fusion is effective for treating chronic low back pain (LBP), but has drawbacks, such as stiffness and possibly adjacent level degradation. Motion-preserving options have emerged, of which TDR is frequently used because of these drawbacks. How the results of TDR compare to fusion, however, is uncertain. One hundred and fifty-two patients with a mean age of 40 years (21–55) were included: 90 were women, and 80 underwent TDR. The patients had not responded to a conservative treatment programme and suffered from predominantly LBP, with varying degrees of leg pain. Diagnosis was based on clinical examination, radiographs, MRI, and in unclear cases, diagnostic injections. Outcome measures were global assessment (GA), VAS for back and leg pain, Oswestry Disability Index, SF36 and EQ5D at 1 and 2 years. Follow-up rate was 100%, at both 1 and 2 years. All outcome variables improved in both groups between preoperative and follow-up assessment. The primary outcome measure, GA, revealed that 30% in the TDR group and 15% in the fusion group were totally pain-free at 2 years (P = 0.031). TDR patients had reached maximum recovery in virtually all variables at 1 year, with significant differences compared to the fusion group. The fusion patients continued to improve and at 2 years had results similar to TDR patients apart from numbers of pain-free. Complications and reoperations were similar in both groups, but pedicle screw removal as additive surgery, was frequent in the fusion group. One year after surgery, TDR was superior to spinal fusion in clinical outcome, but this difference had diminished by 2 years, apart from (VAS for back pain and) numbers of pain-free. The

  17. A case of cervical metastases in a patient with preexisting cervical disc replacement and fusion after 2-year symptom-free interval: when do we need interdisciplinary diagnostics?

    PubMed Central

    Melloh, Markus; Barz, Thomas

    2012-01-01

    Recurrent cervical symptoms frequently occur after cervical disc replacement and fusion. To date, no algorithm for the diagnostic assessment of these symptoms has been established. We present a case report and review of the literature to illustrate the need for interdisciplinary diagnostics in recurrent cervicobrachialgia without pathological cervical imaging. The hospital chart, medical history, physical examination, and imaging of a single patient were reviewed. A 53-year-old man with preexisting cervical disc replacement and fusion presented with a new episode of cervicobrachialgia after a 2-year symptom-free interval. Cervical magnetic resonance imaging (MRI) showed no pathological findings. Six months later the patient reported increasing symptoms including numbness and weakness of the right arm. Repeated cervical MRI and thoracic computed tomography revealed cervical metastases with intraspinal tumor growth and an underlying extensive small cell bronchial carcinoma. In recurrent cervicobrachialgia, without pathological cervical imaging, interdisciplinary diagnostics are needed. Basic diagnostic tests may assist to exclude severe non-vertebrogenic pathologies. PMID:23526906

  18. Adjacent Segment Disease in a Patient With Klippel-Feil Syndrome and Radiculopathy: Surgical Treatment With Two-Level Disc Replacement

    PubMed Central

    Reyes-Sánchez, Alejandro; Rosales-Olivares, Luis Miguel

    2007-01-01

    Klippel-Feil syndrome (KFS) is a complex congenital condition characterized by improper segmentation of cervical motion segments that could contribute to undesirable adjacent segment degeneration. KFS patients have a strong tendency to present with disease in the adjacent segments. When this condition is present, anterior decompression followed by total disc replacement can be performed safely and can lead to good clinical results. This treatment has theoretical advantages compared with anterior decompression and fusion. Comparative studies and long-term follow-up are needed. Complications associated with fusion include loss of a motion segment, disc height loss, subsidence of the graft, progressive degenerative changes at the adjacent level, graft-related complications, and graft-site complications. Such new technologies as motion preservation spine arthroplasty represent attempts to avoid these complications. Here we present a case report of a 62-year-old female patient with type I congenital fusion at the C5–6 level, with a history of neck pain and right radiculopathy at C5–7. X-rays and MRI show evidence of adjacent segment degeneration at levels above and below congenital fusion. The patient's preoperative visual analog score (VAS) for neck pain was 7 out of a possible 10, her score for right upper extremity pain was 8 out of 10, and her Neck Disability Index (NDI) was 32%. Surgical treatment consisted of anterior decompression and total disc replacement at both levels. At 1-year follow-up, the patient's VAS for neck pain was 2 out of 10, her VAS score for right upper extremity pain was 1 of 10, and her NDI was 9%. PMID:25802590

  19. Adjacent segment disease in a patient with klippel-feil syndrome and radiculopathy: surgical treatment with two-level disc replacement.

    PubMed

    Reyes-Sánchez, Alejandro; Zárate-Kalfópulos, Barón; Rosales-Olivares, Luis Miguel

    2007-01-01

    Klippel-Feil syndrome (KFS) is a complex congenital condition characterized by improper segmentation of cervical motion segments that could contribute to undesirable adjacent segment degeneration. KFS patients have a strong tendency to present with disease in the adjacent segments. When this condition is present, anterior decompression followed by total disc replacement can be performed safely and can lead to good clinical results. This treatment has theoretical advantages compared with anterior decompression and fusion. Comparative studies and long-term follow-up are needed. Complications associated with fusion include loss of a motion segment, disc height loss, subsidence of the graft, progressive degenerative changes at the adjacent level, graft-related complications, and graft-site complications. Such new technologies as motion preservation spine arthroplasty represent attempts to avoid these complications. Here we present a case report of a 62-year-old female patient with type I congenital fusion at the C5-6 level, with a history of neck pain and right radiculopathy at C5-7. X-rays and MRI show evidence of adjacent segment degeneration at levels above and below congenital fusion. The patient's preoperative visual analog score (VAS) for neck pain was 7 out of a possible 10, her score for right upper extremity pain was 8 out of 10, and her Neck Disability Index (NDI) was 32%. Surgical treatment consisted of anterior decompression and total disc replacement at both levels. At 1-year follow-up, the patient's VAS for neck pain was 2 out of 10, her VAS score for right upper extremity pain was 1 of 10, and her NDI was 9%.

  20. Utilization trends of cervical artificial disc replacement during the FDA investigational device exemption clinical trials compared to anterior cervical fusion.

    PubMed

    Qureshi, Sheeraz A; Koehler, Steven M; Lu, Young; Cho, Samuel; Hecht, Andrew C

    2013-12-01

    While anterior cervical discectomy and fusion (ACDF) is the gold standard surgical treatment for cervical disc disease, concerns regarding adjacent segment degeneration lead to the development of cervical disc arthroplasty (CDA). This study compares the utilization trends of CDA versus ACDF during the period of the Food and Drug Administration Investigational Device Exemption clinical trials from 2004 to 2007. The Healthcare Cost and Utilization Project Nationwide Inpatient Sample database was used to identify CDA and ACDF procedures performed in the USA between 2004 and 2007. The prevalence of CDA and ACDF procedures was estimated and stratified by age, sex, diagnosis, census region, payor class, and hospital characteristics. The average length of hospital stay, total charges, and costs were also estimated. The number of CDA surgeries significantly increased annually from 2004 to 2007 and mostly took place at urban non-teaching hospitals. There were no regional differences between CDA and ACDF utilization. There was no difference between sex or admission type between CDA and ACDF patients. ACDF patients were older and had more diabetes, hypertension, and chronic obstructive pulmonary disease. CDA patients were more likely to be discharged home and had shorter hospital stays but had a higher rate of deep venous thrombosis than ACDF patients. Significantly more CDA patients had private insurance while more ACDF patients had Medicare. The average cost was higher for ACDF than CDA. While ACDF dominated surgical intervention for cervical disc disease during the trial period, CDA utilization increased at a significantly greater rate suggesting rapid early adoption.

  1. Subsequent surgery rates after cervical total disc replacement using a Mobi-C Cervical Disc Prosthesis versus anterior cervical discectomy and fusion: a prospective randomized clinical trial with 5-year follow-up.

    PubMed

    Jackson, Robert J; Davis, Reginald J; Hoffman, Gregory A; Bae, Hyun W; Hisey, Michael S; Kim, Kee D; Gaede, Steven E; Nunley, Pierce Dalton

    2016-05-01

    OBJECTIVE Cervical total disc replacement (TDR) has been shown in a number of prospective clinical studies to be a viable treatment alternative to anterior cervical discectomy and fusion (ACDF) for the treatment of symptomatic degenerative disc disease. In addition to preserving motion, evidence suggests that cervical TDR may result in a lower incidence of subsequent surgical intervention than treatment with fusion. The goal of this study was to evaluate subsequent surgery rates up to 5 years in patients treated with TDR or ACDF at 1 or 2 contiguous levels between C-3 and C-7. METHODS This was a prospective, multicenter, randomized, unblinded clinical trial. Patients with symptomatic degenerative disc disease were enrolled to receive 1- or 2-level treatment with either TDR as the investigational device or ACDF as the control treatment. There were 260 patients in the 1-level study (179 TDR and 81 ACDF patients) and 339 patients in the 2-level study (234 TDR and 105 ACDF patients). RESULTS At 5 years, the occurrence of subsequent surgical intervention was significantly higher among ACDF patients for 1-level (TDR, 4.5% [8/179]; ACDF, 17.3% [14/81]; p = 0.0012) and 2-level (TDR, 7.3% [17/234]; ACDF, 21.0% [22/105], p = 0.0007) treatment. The TDR group demonstrated significantly fewer index- and adjacent-level subsequent surgeries in both the 1- and 2-level cohorts. CONCLUSIONS Five-year results showed treatment with cervical TDR to result in a significantly lower rate of subsequent surgical intervention than treatment with ACDF for both 1 and 2 levels of treatment. Clinical trial registration no.: NCT00389597 ( clinicaltrials.gov ).

  2. Internal carotid artery dissection after anterior cervical disc replacement: first case report and literature review of vascular complications of the approach.

    PubMed

    Loret, Jean-Edouard; Francois, Patrick; Papagiannaki, Chrysanthi; Cottier, Jean-Philippe; Terrier, Louis-Marie; Zemmoura, Ilyess

    2013-07-01

    We report the case of a 41-year-old woman who underwent cervical total disc replacement at C4C5 and C5C6 levels and fusion at C6C7 level through an anterior right-side approach. After anesthesia recovery, the patient presented left hemiparesia and facial palsy due to large right hemispheric stroke. Diffusion-weighted magnetic resonance imaging was performed as soon as the patient developed neurologic symptoms of stroke and revealed a right internal carotid artery dissection. Digital substraction angiography, endovascular stenting, angioplasty and thrombectomy were performed. Six months after treatment, clinical examination showed mild left-arm spasticity. To the best of our knowledge, only two cases of internal carotid artery stroke without dissection or thrombosis are reported. In conclusion, although vascular complications are rare after anterior cervical spine procedure, internal carotid artery dissection can occur. Suspected risk factors are prolonged retraction of the carotid artery and neck extension.

  3. Cervical artificial disc replacement versus fusion in the cervical spine: a systematic review comparing long-term follow-up results from two FDA trials

    PubMed Central

    Mummaneni, Praveen V.; Amin, Beejal Y.; Wu, Jau-Ching; Brodt, Erika D.; Dettori, Joseph R.; Sasso, Rick C.

    2012-01-01

    Study design: Systematic review. Clinical question: Does single-level unconstrained, semiconstrained, or fully constrained cervical artificial disc replacement (C-ADR) improve health outcomes compared with single-level anterior cervical discectomy and fusion (ACDF) in the long-term? Methods: A systematic review was undertaken for articles published up to October 2011. Electronic databases and reference lists of key articles were searched to identify US Food and Drug Administration (FDA) studies reporting long-term (≥ 48 months) follow-up results of C-ADR compared with ACDF. Non-FDA trials and FDA trials reporting outcomes at short-term or mid-term follow-up periods were excluded. Two independent reviewers assessed the strength of evidence using the GRADE criteria and disagreements were resolved by consensus. Results: Two FDA trials reporting outcomes following C-ADR (Bryan disc, Prestige disc) versus ACDF at follow-up periods of 48 months and 60 months were found (follow-up rates are 68.7% [318/463] and 50.1% [271/541], respectively). Patients in the C-ADR group showed a higher rate of overall success, greater improvements in Neck Disability Index, neck and arm pain scores, and SF-36 PhysicalComponent Scores at long-term follow-up compared with those in the ACDF group. The rate of adjacent segment disease was less in the C-ADR group versus the ACDF group at 60 months (2.9% vs 4.9%). Normal segmental motion was maintained in the C-ADR group. Furthermore, rates of revision and supplemental fixation surgical procedures were lower in the arthroplasty group. Conclusions: C-ADR is a viable treatment option for cervical herniated disc/spondylosis with radiculopathy resulting in improved clinical outcomes, maintenance of normal segmental motion, and low rates of subsequent surgical procedures at 4 to 5 years follow-up. More studies with long-term follow-up are warranted. PMID:23236315

  4. Comparative Analysis between Total Disc Replacement and Posterior Foraminotomy for Posterolateral Soft Disc Herniation with Unilateral Radiculopathy : Clinical and Biomechanical Results of a Minimum 5 Years Follow-up

    PubMed Central

    Kim, Kyoung-Tae; Cho, Dae-Chul; Sung, Joo-Kyung; Kim, Young-Baeg; Kim, Du Hwan

    2017-01-01

    Objective To compare the clinical outcomes and biomechanical effects of total disc replacement (TDR) and posterior cervical foraminotomy (PCF) and to propose relative inclusion criteria. Methods Thirty-five patients who underwent surgery between 2006 and 2008 were included. All patients had single-level disease and only radiculopathy. The overall sagittal balance and angle and height of a functional segmental unit (FSU; upper and lower vertebral body of the operative lesion) were assessed by preoperative and follow-up radiographs. C2–7 range of motion (ROM), FSU, and the adjacent segment were also checked. Results The clinical outcome of TDR (group A) was tended to be superior to that of PCF (group B) without statistical significance. In the group A, preoperative and postoperative upper adjacent segment level motion values were 8.6±2.3 and 8.4±2.0, and lower level motion values were 8.4±2.2 and 8.3±1.9. Preoperative and postoperative FSU heights were 37.0±2.1 and 37.1±1.8. In the group B, upper level adjacent segment motion values were 8.1±2.6 and 8.2±2.8, and lower level motion values were 6.5±3.3 and 6.3±3.1. FSU heights were 37.1±2.0 and 36.2±1.8. The postoperative FSU motion and height changes were significant (p<0.05). The patient’s satisfaction rates for surgery were 88.2% in group A and 88.8% in group B. Conclusion TDR and PCF have favorable outcomes in patients with unilateral soft disc herniation. However, patients have different biomechanical backgrounds, so the patient’s biomechanical characteristics and economic status should be understood and treated using the optimal procedure. PMID:28061490

  5. Comparison of single-level L4–L5 versus L5–S1 lumbar disc replacement: results and prognostic factors

    PubMed Central

    Bundy, Albert; Costantini, Sandro; Nena, Ugo; Finocchiaro, Francesco; Monterumici, Daniele A. Fabris

    2009-01-01

    The aim of our prospective non-randomized clinical study was to analyze operative data, short-term results, safety, efficacy, complications, and prognostic factors for single-level total lumbar disc replacement (TLDR), and to compare results between different levels (L4–L5 vs. L5–S1). Thirty-six patients with single-level L4–L5 or L5–S1 TLDR, with 1-year minimum follow-up (FU), had complete clinical [SF36, visual analog scale (VAS), Oswestry Disability Index (ODI)] and radiological data, and were included in our study. Mean FU was 38.67 ± 17.34 months. Replaced level was L4–L5 in 12 (33.3%) cases, and L5–S1 in 24 cases (66.7%). Mean age at diagnosis was 41.17 ± 7.14 years. 24 (66.7%) were females and 12 (33.3%) were males. Statistical analyses were assessed using t tests or Mann–Whitney test for continuous variables and Chi-square test or Fisher’s exact test analyses for categorical variables. Univariate linear regression and binary logistic regression analyses were utilized to evaluate the relationship between surgical outcomes and covariates (gender, age, etiology, treated level, pre-operative SF36, ODI, and VAS). Mean operative time was 147.03 ± 30.03 min. Mean hospital stay was 9.69 ± 5.39 days, and mean return to ambulation was 4.31 ± 1.17 days. At 1-year FU, patients revealed a statistical significant improvement in VAS pain (P = 0.000), ODI lumbar function (P = 0.000), and SF36 general health status (P = 0.000). Single-level TLDR is a good alternative to fusion for chronic discogenic low back pain refractory to conservative measures. Our study confirmed satisfactory clinical results for monosegmental L4–L5 and L5–S1 disc prosthesis, with no difference between the two different levels for SF36 (P = 0.217), ODI (P = 0.527), and VAS (P = 0.269). However, replacement of the L4–L5 disc is affected by an increased risk of complication (P = 0.000). There were no prognostic factors for intraoperative blood

  6. Influence of preoperative nucleus pulposus status and radiculopathy on outcomes in mono-segmental lumbar total disc replacement: results from a nationwide registry

    PubMed Central

    2011-01-01

    Background Currently, herniated nucleus pulposus (HNP) with radiculopathy and other preconditions are regarded as relative or absolute contraindications for lumbar total disc replacement (TDR). In Switzerland it is left to the surgeon's discretion when to operate. The present study is based on the dataset of SWISSspine, a governmentally mandated health technology assessment registry. We hypothesized that preoperative nucleus pulposus status and presence or absence of radiculopathy has an influence on clinical outcomes in patients treated with mono-segmental lumbar TDR. Methods Between March 2005 and April 2009, 416 patients underwent mono-segmental lumbar TDR, which was documented in a prospective observational multicenter mode. The data collection consisted of perioperative and follow-up data (physician based) and clinical outcomes (NASS, EQ-5D). Patients were divided into four groups according to their preoperative status: 1) group degenerative disc disease ("DDD"): 160 patients without HNP and no radiculopathy, classic precondition for TDR; 2) group "HNP-No radiculopathy": 68 patients with HNP but without radiculopathy; 3) group "Stenosis": 73 patients without HNP but with radiculopathy, and 4) group "HNP-Radiculopathy": 132 patients with HNP and radiculopathy. The groups were compared regarding preoperative patient characteristics and pre- and postoperative VAS and EQ-5D scores using general linear modeling. Results Demographics in all four groups were comparable. Regarding the improvement of quality of life (EQ-5D) there were no differences across the four groups. For the two main groups DDD and HNP-Radiculopathy no differences were found in the adjusted postoperative back- and leg pain alleviation levels, in the stenosis group back- and leg pain relief were lower. Conclusions Despite higher preoperative leg pain levels, outcomes in lumbar TDR patients with HNP and radiculopathy were similar to outcomes in patients with the classic indication; this because

  7. Submicron sized ultra-high molecular weight polyethylene wear particle analysis from revised SB Charité III total disc replacements.

    PubMed

    Punt, Ilona; Baxter, Ryan; van Ooij, André; Willems, Paul; van Rhijn, Lodewijk; Kurtz, Steven; Steinbeck, Marla

    2011-09-01

    Submicron sized particles are frequently observed in retrieved total hip and knee periprosthetic tissues and appear to be critical in the activation of the phagocytic inflammatory response. In this paper the concentration, size and shape of ultra-high molecular weight polyethylene (UHMWPE) wear particles between 0.05 and 2.00μm were determined after isolation from periprosthetic tissues from retrieved lumbar SB Charité III total disc replacements (TDR) using scanning electron microscopy (SEM). For comparison, UHMWPE wear particles were isolated from γ-radiation-air sterilized total hip arthroplasty (THA) revision tissues. The mean concentration of UHMWPE particles in TDR tissues was 1.6×10(9)g(-1)tissue (range 1.3-2.0), which was significantly lower than the concentration of 2.3×10(9)g(-1) THA revision tissue (range 1.8-3.2) (P=0.03). The mean particle size (equivalent circular diameter: TDR, 0.46μm; THA 0.53μm, P=0.60) and mean shape were comparable between TDR and THA (aspect ratio: TDR, 1.89; THA, 1.99, P=0.35; roundness: TDR, 0.58; THA, 0.56, P=0.35). However, the TDR particles tended to be smaller and more round. Although no correlations were found between visible damage to the UHMWPE core and the concentration or shape of the UHMWPE particles, a positive correlation was found between increasing particle size and increasing rim penetration of the TDR core (P=0.04). The presence of UHMWPE particles of similar size and shape in TDR tissue, albeit lower in concentration, might explain why, unlike THA, pain rather than osteolysis is the major reason for revision surgery.

  8. Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

    PubMed Central

    Punt, Ilona M.; Austen, Shennah; Cleutjens, Jack P.M.; Kurtz, Steven M.; ten Broeke, René H.M.; van Rhijn, Lodewijk W.; Willems, Paul C.; van Ooij, André

    2011-01-01

    Study design Comparative study. Objective To compare periprosthetic tissue reactions observed after total disc replacement (TDR), total hip arthroplasty (THA) and total knee arthroplasty (TKA) revision surgery. Summary of background data Prosthetic wear debris leading to particle disease, followed by osteolysis, is often observed after THA and TKA. Although the presence of polyethylene (PE) particles and periprosthetic inflammation after TDR has been proven recently, osteolysis is rarely observed. The clinical relevance of PE wear debris in the spine remains poorly understood. Methods Number, size and shape of PE particles, as well as quantity and type of inflammatory cells in periprosthetic tissue retrieved during Charité TDR (n=22), THA (n=10) and TKA (n=4) revision surgery were compared. Tissue samples were stained with hematoxylin/eosin and examined by using light microscopy with bright field and polarized light. Results After THA, large numbers of PE particles <6 µm were observed, which were mainly phagocytosed by macrophages. The TKA group had a broad size range with many larger PE particles and more giant cells. In TDR, the size range was similar to that observed in TKA. However, the smallest particles were the most prevalent with 75% of the particles being <6 µm, as seen in revision THA. In TDR, both macrophages and giant cells were present with a higher number of macrophages. Conclusions Both small and large PE particles are present after TDR revision surgery compatible with both THA and TKA wear patterns. The similarities between periprosthetic tissue reactions in the different groups may give more insight in the clinical relevance of PE particles and inflammatory cells in the lumbar spine. The current findings may help to improve TDR design as applied from technologies previously developed in THA and TKA with the goal of a longer survival of TDR. PMID:21336235

  9. Thirty-day readmission and reoperation rates after single-level anterior cervical discectomy and fusion versus those after cervical disc replacement.

    PubMed

    Bhashyam, Niketh; De la Garza Ramos, Rafael; Nakhla, Jonathan; Nasser, Rani; Jada, Ajit; Purvis, Taylor E; Sciubba, Daniel M; Kinon, Merritt D; Yassari, Reza

    2017-02-01

    OBJECTIVE The goal of this study was to compare 30-day readmission and reoperation rates after single-level anterior cervical discectomy and fusion (ACDF) versus those after cervical disc replacement (CDR). METHODS The authors used the 2013-2014 American College of Surgeons National Surgical Quality Improvement Program database. Included were adult patients who underwent first-time single-level ACDF or CDR for cervical spondylosis or disc herniation. Primary outcome measures were readmission and/or reoperation within 30 days of the original surgery. Logistic regression analysis was used to assess the independent effect of the procedure (ACDF or CDR) on outcome, and results are presented as odds ratios with 95% confidence intervals. RESULTS A total of 6077 patients met the inclusion criteria; 5590 (92.0%) patients underwent single-level ACDF, and 487 (8.0%) patients underwent CDR. The readmission rates were 2.6% for ACDF and 0.4% for CDR (p = 0.003). When stratified according to age groups, only patients between the ages of 41 and 60 years who underwent ACDF had a significantly higher readmission rate than those who underwent CDR (2.5% vs 0.7%, respectively; p = 0.028). After controlling for patient age, sex, body mass index, smoking status, history of chronic obstructive pulmonary disease (COPD), diabetes, hypertension, steroid use, and American Society of Anesthesiologists (ASA) class, patients who underwent CDR were significantly less likely to undergo readmission within 30 days than patients who underwent ACDF (OR 0.23 [95% CI 0.06-0.95]; p = 0.041). Patients with a history of COPD (OR 1.97 [95% CI 1.08-3.57]; p = 0.026) or hypertension (OR 1.62 [95% CI 1.10-2.38]; p = 0.013) and those at ASA Class IV (OR 14.6 [95% CI 1.69-125.75]; p = 0.015) were significantly more likely to require readmission within 30 days. The reoperation rates were 1.2% for ACDF and 0.4% for CDR (p = 0.086), and multivariate analysis revealed that CDR was not associated with lower odds of

  10. The use of a novel injectable hydrogel nucleus pulposus replacement in restoring the mechanical properties of cyclically fatigued porcine intervertebral discs.

    PubMed

    Balkovec, Christian; Vernengo, Jennifer; McGill, Stuart M

    2013-06-01

    Repeated flexion and extension of an intervertebral disc has been shown to affect the angular stiffness of spinal motion segments and is a barometer of the mechanical integrity of the disc. A degenerated disc that loses height causes higher levels of stress on the annulus and facet joints which may increase its level of degeneration; restoring disc height may therefore help to slow this degenerative cascade. Previous research has indicated that nucleus implants have the potential to improve the mechanical characteristics of a disc and an implant that is custom-fit to the intervertebral disc yields the best results with respect to decreasing annular degeneration. Two groups of porcine spinal motion segments were exposed to repeated flexion and extension. One group was then injected with a novel hydrogel while the other group was used as a control. Both groups were then exposed to another round of cyclic flexion and extension to examine the effect that the hydrogel had on restoring the original mechanics to the motion segments. Angular stiffness was restored to the group which received the hydrogel injection in addition to a significant improvement in specimen height. No significant changes were seen in the group which did not receive an injection. It would appear that use of the novel injectable hydrogel is able to restore angular stiffness to cyclically fatigued spinal motion segments. It is also important to note that continued repetition of the event causing specimen fatigue after performing hydrogel injection will result in an eventual return to the same fatigued state.

  11. Seven PC Purchasing Pitfalls.

    ERIC Educational Resources Information Center

    Wodarz, Nan

    1997-01-01

    Explores how to avoid common pitfalls when schools purchase computer equipment. Purchasing tips are provided in the areas of choosing multiple platforms, buying the cheapest model available, choosing a proprietary design, falling for untested technology, purchasing systems that are not upgradable, ignoring extended warranties, and failing to plan…

  12. Pitfalls in laparoscopic cholecystectomy.

    PubMed

    Yvergneaux, J P; Kint, M; Kuppens, E

    1994-01-01

    On the basis of literature and of 475 laparoscopic cholecystectomies of the authors, some pitfalls are reviewed. The circumstances, the mechanism and the prevention of injuries were detailed together with the connected problem of postoperative bile leakage. Among the cholangiographic pitfalls the importance of detection of congenital and acquired anomalies of the biliary tree by means of preoperative ERCP or intraoperative trans-cystic cholangiograms was emphasized. A particular study was made of 3 pictures: Mirizzi syndrome; stone impaction in Vater's papilla; no retrograde flow of the common hepatic duct on intraoperative cholangiograms. Biliodigestive fistulas were briefly commented. The problems with cystic duct stones, particularly the treatment of stones in a long, low inserted cystic duct with retroduodenal course and the closing of thick-walled or wide cystic stumps, were explained. In patients with intraoperative residual common bile duct stones and with failed preoperative catheterization of the papilla, the authors advocate their double approach technique. This combined intraoperative laparoscopic and postoperative endoscopic procedure is carried out via the same transcystic polythene catheters as used for cholangiography and external biliary drainage of the common bile duct.

  13. Intervertebral disc properties: challenges for biodevices.

    PubMed

    Costi, John J; Freeman, Brian J C; Elliott, Dawn M

    2011-05-01

    Intervertebral disc biodevices that employ motion-preservation strategies (e.g., nucleus replacement, total disc replacement and posterior stabilization devices) are currently in use or in development. However, their long-term performance is unknown and only a small number of randomized controlled trials have been conducted. In this article, we discuss the following biodevices: interbody cages, nuclear pulposus replacements, total disc replacements and posterior dynamic stabilization devices, as well as future biological treatments. These biodevices restore some function to the motion segment; however, contrary to expectations, the risk of adjacent-level degeneration does not appear to have been reduced. The short-term challenge is to replicate the complex biomechanical function of the motion segment (e.g., biphasic, viscoelastic behavior and nonlinearity) to improve the quality of motion and minimize adjacent level problems, while ensuring biodevice longevity for the younger, more active patient. Biological strategies for regeneration and repair of disc tissue are being developed and these offer exciting opportunities (and challenges) for the longer term. Responsible introduction and rigorous assessment of these new technologies are required. In this article, we will describe the properties of the disc, explore biodevices currently in use for the surgical treatment of low back pain (with an emphasis on lumbar total disc replacement) and discuss future directions for biological treatments. Finally, we will assess the challenges ahead for the next generation of biodevices designed to replace the disc.

  14. Techniques and pitfalls with the Salto prosthesis: our experience of the first 15 years.

    PubMed

    Colombier, J A; Judet, Th; Bonnin, M; Gaudot, F

    2012-12-01

    The Salto total ankle replacement system has shown to be a viable alternative in the treatment of symptomatic arthritis. However, although outcomes after total ankle replacement are promising, an exact analysis of surgical technique could help to improve them. Based on a 15 years experience with the Salto Total Ankle replacement system, the uthors discuss the surgical technique and its pitfalls, its inications and limitations in current practice.

  15. Motor neurone disease: diagnostic pitfalls.

    PubMed

    Williams, Timothy L

    2013-02-01

    The misdiagnosis of MND (particularly of the ALS phenotype), is uncommon. Atypical presentations, particularly of focal onset and with pure LMN or UMN signs, present a more difficult diagnostic challenge, although perhaps reassuringly, treatable mimics are rare. A working knowledge of potential alternative conditions and MND diagnostic pitfalls should help to reduce the misdiagnosis rate, particularly if the key points are considered.

  16. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... by a typewriter or machine printer in permanent dark ink or its equivalent; and (v) Presented in a... accompanied by a statement that the replacement compact disc contains no new matter. The compact disc and...

  17. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... permanent dark ink or its equivalent; and (v) Presented in a form having sufficient clarity and contrast... statement that the replacement compact disc contains no new matter. The compact disc and copy must...

  18. Redundant disc

    NASA Technical Reports Server (NTRS)

    Barack, W. N.; Domas, P. A.; Beekman, S. W. (Inventor)

    1978-01-01

    A rotatable disc is described that consists of parallel plates tightly joined together for rotation about a hub. Each plate is provided with several angularly projecting spaced lands. The lands of each plate are interposed in alternating relationship between the lands of the next adjacent plate. In this manner, circumferential displacement of adjacent sectors in any one plate is prevented in the event that a crack develops. Each plate is redundantly sized so that, in event of structural failure of one plate, the remaining plates support a proportionate share of the load of the failed plate. The plates are prevented from separating laterally through the inclusion of generally radially extending splines which are inserted to interlock cooperating, circumferentially adjacent lands.

  19. Common System and Software Testing Pitfalls

    DTIC Science & Technology

    2014-11-03

    Book or Supplement to 1st Edition Potential Testing Pitfalls Wiki 13Common System/SW Testing PitfallsDonald G. Firesmith, 3 November 2014 Goals and...changes and incorrect hidden assumptions are uncovered. • Testing is less effective and takes longer than necessary. 16Common System/SW Testing

  20. DISC VARIANCE OF THE HARKEN MITRAL PROSTHESIS: THE CONTRIBUTION OF ASSOCIATED AORTIC REGURGITATION

    PubMed Central

    Yarnoz, Michael D.; Hueter, David; McCormick, John R.; Black, Harrison; Berger, Robert L.

    1977-01-01

    Four cases of severe mitral regurgitation due to disc variance of the Harken disc prosthesis in the mitral position are described. The valve occluder actually escaped into the left atrium in two patients, and neither survived despite emergency valve replacement. In the other two, disc malfunction was identified by flouroscopy, the prosthesis was replaced, and both patients survived. All four patients had associated aortic regurgitation, which most likely contributed to erosion of the disc edges. It is suggested that patients with the Harken disc prosthesis undergo periodic evaluation to detect abnormal disc motion. Images PMID:15216088

  1. Clinically-Relevant Cell Sources for TMJ Disc Engineering

    PubMed Central

    Johns, D.E.; Wong, M. E.; Athanasiou, K.A.

    2010-01-01

    Tissue-engineering of the temporomandibular joint (TMJ) disc aims to provide patients with TMJ disorders an option to replace diseased tissue with autologous, functional tissue. This study examined clinically-relevant cell sources by comparing costal chondrocytes, dermal fibroblasts, a mixture of the two, and TMJ disc cells in a scaffoldless tissue-engineering approach. It was hypothesized that all constructs would produce matrix relevant to the TMJ disc, but the mixture constructs were expected to appear most like the TMJ disc constructs. Costal chondrocyte and mixture constructs were morphologically and biochemically superior to the TMJ disc and dermal fibroblast constructs, and their compressive properties were not significantly different. Costal chondrocyte constructs produced almost 40 times more collagen and 800 times more glycosaminoglycans than TMJ constructs. This study demonstrates the ability of costal chondrocytes to produce extracellular matrix that may function in a TMJ disc replacement. PMID:18502963

  2. Stellar discs in Aquarius dark matter haloes

    NASA Astrophysics Data System (ADS)

    DeBuhr, Jackson; Ma, Chung-Pei; White, Simon D. M.

    2012-10-01

    We investigate the gravitational interactions between live stellar discs and their dark matter haloes, using Λ cold dark matter haloes similar in mass to that of the Milky Way taken from the Aquarius Project. We introduce the stellar discs by first allowing the haloes to respond to the influence of a growing rigid disc potential from z = 1.3 to 1.0. The rigid potential is then replaced with star particles which evolve self-consistently with the dark matter particles until z = 0.0. Regardless of the initial orientation of the disc, the inner parts of the haloes contract and change from prolate to oblate as the disc grows to its full size. When the disc's normal is initially aligned with the major axis of the halo at z = 1.3, the length of the major axis contracts and becomes the minor axis by z = 1.0. Six out of the eight discs in our main set of simulations form bars, and five of the six bars experience a buckling instability that results in a sudden jump in the vertical stellar velocity dispersion and an accompanying drop in the m = 2 Fourier amplitude of the disc surface density. The bars are not destroyed by the buckling but continue to grow until the present day. Bars are largely absent when the disc mass is reduced by a factor of 2 or more; the relative disc-to-halo mass is therefore a primary factor in bar formation and evolution. A subset of the discs is warped at the outskirts and contains prominent non-coplanar material with a ring-like structure. Many discs reorient by large angles between z = 1 and 0, following a coherent reorientation of their inner haloes. Larger reorientations produce more strongly warped discs, suggesting a tight link between the two phenomena. The origins of bars and warps appear independent: some discs with strong bars show little disturbances at the outskirts, while the discs with the weakest bars show severe warps.

  3. How Does Lumbar Degenerative Disc Disease Affect the Disc Deformation at the Cephalic Levels In Vivo?

    PubMed Central

    Wang, Shaobai; Xia, Qun; Passias, Peter; Li, Weishi; Wood, Kirkham; Li, Guoan

    2013-01-01

    level and the level one above experienced higher tensile and shear deformations during end ranges of lumbar motion in the patients with DDD before surgical treatments when compared with the healthy subjects. The larger disc deformations at the cephalic segments were otherwise not detectable using conventional magnetic resonance imaging techniques. Future studies should investigate the effect of surgical treatments, such as fusion or disc replacement, on the biomechanics of the adjacent segments during end ranges of lumbar motion. PMID:21245781

  4. Fractured occluder disc: a previously unrecognized complication of the Starr-Edwards disc prosthesis.

    PubMed

    Malouf, J F; Hannoush, H M; Odell, J A

    2001-01-01

    Fracture of the occluder disc of a low-profile Starr-Edwards prosthesis is a hitherto unrecognized complication. We describe a patient who presented with right heart failure and severe pulmonary hypertension 27 years after mitral valve replacement with a model 6520 caged-disc prosthesis. At surgery, there was a longitudinal split in the occluder disc, and organized thrombus was lodged between the split segments. This case offers a unique opportunity to study the long-term effects of wear on the polyethylene poppet and Stellite cage.

  5. Cell transplantation in lumbar spine disc degeneration disease.

    PubMed

    Hohaus, C; Ganey, T M; Minkus, Y; Meisel, H J

    2008-12-01

    Low back pain is an extremely common symptom, affecting nearly three-quarters of the population sometime in their life. Given that disc herniation is thought to be an extension of progressive disc degeneration that attends the normal aging process, seeking an effective therapy that staves off disc degeneration has been considered a logical attempt to reduce back pain. The most apparent cellular and biochemical changes attributable to degeneration include a decrease in cell density in the disc that is accompanied by a reduction in synthesis of cartilage-specific extracellular matrix components. With this in mind, one therapeutic strategy would be to replace, regenerate, or augment the intervertebral disc cell population, with a goal of correcting matrix insufficiencies and restoring normal segment biomechanics. Biological restoration through the use of autologous disc chondrocyte transplantation offers a potential to achieve functional integration of disc metabolism and mechanics. We designed an animal study using the dog as our model to investigate this hypothesis by transplantation of autologous disc-derived chondrocytes into degenerated intervertebral discs. As a result we demonstrated that disc cells remained viable after transplantation; transplanted disc cells produced an extracellular matrix that contained components similar to normal intervertebral disc tissue; a statistically significant correlation between transplanting cells and retention of disc height could displayed. Following these results the Euro Disc Randomized Trial was initiated to embrace a representative patient group with persistent symptoms that had not responded to conservative treatment where an indication for surgical treatment was given. In the interim analyses we evaluated that patients who received autologous disc cell transplantation had greater pain reduction at 2 years compared with patients who did not receive cells following their discectomy surgery and discs in patients that

  6. Fusion versus Bryan Cervical Disc in two-level cervical disc disease: a prospective, randomised study

    PubMed Central

    Nie, Lin; Zhang, Li; Hou, Yong

    2008-01-01

    In this prospective study, our aim was to compare the functional results and radiographic outcomes of fusion and Bryan Cervical Disc replacement in the treatment of two-level cervical disc disease. A total of 65 patients with two-level cervical disc disease were randomly assigned to two groups, those operated on with Bryan Cervical Disc replacement (31) and those operated on with anterior cervical fusion with an iliac crest autograft and plate (34). Clinical evaluation was carried out using the visual analogue scale (VAS), the Short Form 36 (SF-36) and the neck disability index (NDI) during a two year follow-up. Radiological evaluation sought evidence of range of motion, stability and subsidence of the prosthesis. Substantial reduction in NDI scores occurred in both groups, with greater percent improvement in the Bryan group (P = 0.023). The arm pain VAS score improvement was substantial in both groups. Bryan artificial cervical disc replacement seems reliable and safe in the treatment of patients with two-level cervical disc disease. PMID:18956190

  7. Cocking of a poppet-disc prosthesis in the aortic position. A cause of intermittent aortic regurgitation.

    PubMed

    Hammer, W J; Hearne, M J; Roberts, W C

    1976-02-01

    Intermittent aortic regurgitation due to cocking is described for the first time after replacement of the aortic valve with a poppet-disc prosthesis. A combination of disc grooving and strut thrombus produced the cocking with resultant aortic regurgitation.

  8. Turbine disc sealing assembly

    DOEpatents

    Diakunchak, Ihor S.

    2013-03-05

    A disc seal assembly for use in a turbine engine. The disc seal assembly includes a plurality of outwardly extending sealing flange members that define a plurality of fluid pockets. The sealing flange members define a labyrinth flow path therebetween to limit leakage between a hot gas path and a disc cavity in the turbine engine.

  9. MECHANICAL DESIGN CRITERIA FOR INTERVERTEBRAL DISC TISSUE ENGINEERING

    PubMed Central

    Nerurkar, Nandan L.; Elliott, Dawn M.; Mauck, Robert L.

    2009-01-01

    Due to the inability of current clinical practices to restore function to degenerated intervertebral discs, the arena of disc tissue engineering has received substantial attention in recent years. Despite tremendous growth and progress in this field, translation to clinical implementation has been hindered by a lack of well-defined functional benchmarks. Because successful replacement of the disc is contingent upon replication of some or all of its complex mechanical behaviour, it is critically important that disc mechanics be well characterized in order to establish discrete functional goals for tissue engineering. In this review, the key functional signatures of the intervertebral disc are discussed and used to propose a series of native tissue benchmarks to guide the development of engineered replacement tissues. These benchmarks include measures of mechanical function under tensile, compressive and shear deformations for the disc and its substructures. In some cases, important functional measures are identified that have yet to be measured in the native tissue. Ultimately, native tissue benchmark values are compared to measurements that have been made on engineered disc tissues, identifying measures where functional equivalence was achieved, and others where there remain opportunities for advancement. Several excellent reviews exist regarding disc composition and structure, as well as recent tissue engineering strategies; therefore this review will remain focused on the functional aspects of disc tissue engineering. PMID:20080239

  10. ROI, Pitfalls and Best Practices with an Enterprise Smart Card Deployment

    NASA Astrophysics Data System (ADS)

    Hoyer, Philip

    This paper will describe the highlights of the ActivIdentity sponsored Datamonitor study into Return On Investment (ROI) when implementing smart cards in the enterprise in the following areas: physical and logical access convergence, remote access when replacing OTP tokens and Enterprise Single Sign-On. It also provides additional information about the pitfalls to avoid when implementing smart cards and describes best practices for deployment.

  11. The First 18 Months Following Food and Drug Administration Approval of Lumbar Total Disc Replacement in the United States: Reported Adverse Events Outside an Investigational Device Exemption Study Environment

    PubMed Central

    Guyer, Richard D.; Geisler, Fred H.; McAfee, Paul C.; Regan, John J.

    2007-01-01

    Background Introduction of a new surgical technology may result in higher rates of adverse events compared with rates reported in the study performed to gain regulatory approval. The purpose of our study was to describe the incidence of reported adverse events during the first 18 months following US Food and Drug Administration (FDA) approval of the first lumbar arthroplasty device available in the United States and to discern data trends. Methods Reports of adverse events submitted to the FDA in patients receiving the Charité artificial disc were reviewed and pooled by similarity. We analyzed 135 medical device reports filed with the FDA regarding the Charité artificial disc between October 26, 2004, and April 26, 2006. Sixteen reports were excluded for lack of information regarding cause or because described events were vague or unrelated to the procedure. Results Rate of adverse events reported to the FDA as a percentage of devices of which the device manufacturer was aware had been dispensed at 6, 12, and 18 months following approval was 0.58%, 2.34%, and 2.13%, respectively. The adverse event reported most frequently through 18 months was anterior migration with reoperation (0.65%); other reported adverse events were, in decreasing order, sizing and malposition errors resulting in reoperation (0.36%), posterior element fracture resulting in reoperation (0.30%), major vascular injury requiring a blood transfusion (0.23%), and subsidence requiring reoperation (0.20%). Three non–device-related patient deaths were reported following FDA approval. The reported rate of sizing/malposition errors leading to reoperation of 0.36% was the same rate as that seen in the investigational device exemption (IDE) study of the Charité artificial disc. All other reported rates were lower than rates of the same events reported in the study. Conclusions Medical device reporting is an important yet highly anecdotal and incomplete event-tracking process. However, it is the

  12. Pitfalls in the performance and interpretation of clinical immunology tests.

    PubMed

    Lock, R J; Virgo, P F; Unsworth, D J

    2008-12-01

    A broad overview, with examples, of the potential pitfalls encountered in the clinical immunology laboratory is presented. Illustrative examples and case scenarios are provided from autoimmunity, immunochemistry and cellular immunology, looking at both technical and interpretative pitfalls.

  13. Reproducibility Issues: Avoiding Pitfalls in Animal Inflammation Models.

    PubMed

    Laman, Jon D; Kooistra, Susanne M; Clausen, Björn E

    2017-01-01

    In light of an enhanced awareness of ethical questions and ever increasing costs when working with animals in biomedical research, there is a dedicated and sometimes fierce debate concerning the (lack of) reproducibility of animal models and their relevance for human inflammatory diseases. Despite evident advancements in searching for alternatives, that is, replacing, reducing, and refining animal experiments-the three R's of Russel and Burch (1959)-understanding the complex interactions of the cells of the immune system, the nervous system and the affected tissue/organ during inflammation critically relies on in vivo models. Consequently, scientific advancement and ultimately novel therapeutic interventions depend on improving the reproducibility of animal inflammation models. As a prelude to the remaining hands-on protocols described in this volume, here, we summarize potential pitfalls of preclinical animal research and provide resources and background reading on how to avoid them.

  14. Ankle replacement

    MedlinePlus

    ... is surgery to replace the damaged bone and cartilage in the ankle joint. Artificial joint parts (prosthetics) ... Your surgeon will remove the damaged bone and cartilage. Your surgeon will replace the damaged part of: ...

  15. Hip Replacement

    MedlinePlus

    ... replacement is an operation in which a damaged hip joint is removed and replaced with an artificial joint. ... are many medical conditions that can damage the hip joint. (Watch the video to learn about what goes ...

  16. [Pitfalls in the treatment of periodontitis].

    PubMed

    Casteyde, J P; Occhiminuti, M A; Achache, S; Netter, J C

    1984-01-01

    The author point out that periodontitis is a disease of multiple aetiology and indicate two types of pitfall: traps in conceiving the plan of treatment and traps in carrying out treatment. The treatment plan may be incomplete. The authors show that the deepest types of vertical alveolysis are always related to occlusal or functional imbalance and that treatment based only upon hygiene and periodontal surgery represents a pitfall. They stress the importance of functional treatment. However such complex functional treatment itself has a number of pitfalls when it is being carried out. It is essential to restore balance of the oro-facial musculature before any treatment of occlusion. These are also types of non-occlusal musculo-dental imbalance which may plan an important role in the course of periodontitis. In conclusion, the authors note that functional treatment of the manducatory apparatus is as important as controlling inflammation. This must not be underestimated nor be allowed to go unrecognised.

  17. Common problems and pitfalls in gear design

    NASA Technical Reports Server (NTRS)

    Townsend, Dennis P.

    1986-01-01

    There are several pitfalls and problems associated with the successful design of a new gear transmission. A new design will require the knowledge and experience of several technical areas of engineering. Most of the pitfalls and problems associated with a new design are related to an inadequate evaluation of several areas, such as, the lubrication and cooling requirements, complete static and dynamic load analysis, evaluation of materials and heat treatment and the latest manufacturing technology. Some of the common problems of the gear design process are discussed with recommendations made for avoiding these conditions.

  18. Menopause causes vertebral endplate degeneration and decrease in nutrient diffusion to the intervertebral discs.

    PubMed

    Wang, Yi-Xiang J; Griffith, James F

    2011-07-01

    The vasculature in the outer annulus supplies only the periphery of the disc so that nutrition to the bulk of the disc, including all the inner annulus and nucleus pulposus, is derived from the vertebral epiphyseal end arteries where nutrients diffuse across the cartilaginous endplate to reach the disc. In this regard the vertebral endplate plays an important role in disc nutrition. Compromise of diffusion of nutrients to the disc cells may play a large part in the progression or even initiation of disc degeneration. Increasing evidence suggests that estrogen deficiency also influence the severity of disc degeneration in post-menopausal females. Structural disorganization of the vertebral endplate occurs with disc degeneration, with the most common endplate changes observed clinically being Schmorl's node. Schmorl's node is more commonly seen in post-menopausal women than younger women. Osteosclerosis, osteonecrosis and fibrosis associated with Schmorl's nodes can impede nutrient diffusion into the disc as well as removal of metabolites from the disc. We hypothesize that menopause negatively affects vertebral endplate quality and induces endplate degeneration. This endplate degeneration decreases nutrients diffusion from vertebral body into discs, and also impedes removal of metabolites, leads to further disc degeneration. To confirm our hypothesis, a cross-sectional post-contrast MRI study can be performed in pre-menopausal and post-menopausal women. If the hypothesis is confirmed, then low dose hormone replacement treatment may retard disc degeneration in post menopausal women and thereby limit the consequences associated with disc degeneration such as low back pain.

  19. Investigation of Product Performance of Al-Metal Matrix Composites Brake Disc using Finite Element Analysis

    NASA Astrophysics Data System (ADS)

    Fatchurrohman, N.; Marini, C. D.; Suraya, S.; Iqbal, AKM Asif

    2016-02-01

    The increasing demand of fuel efficiency and light weight components in automobile sectors have led to the development of advanced material parts with improved performance. A specific class of MMCs which has gained a lot of attention due to its potential is aluminium metal matrix composites (Al-MMCs). Product performance investigation of Al- MMCs is presented in this article, where an Al-MMCs brake disc is analyzed using finite element analysis. The objective is to identify the potentiality of replacing the conventional iron brake disc with Al-MMCs brake disc. The simulation results suggested that the MMCs brake disc provided better thermal and mechanical performance as compared to the conventional cast iron brake disc. Although, the Al-MMCs brake disc dissipated higher maximum temperature compared to cast iron brake disc's maximum temperature. The Al-MMCs brake disc showed a well distributed temperature than the cast iron brake disc. The high temperature developed at the ring of the disc and heat was dissipated in circumferential direction. Moreover, better thermal dissipation and conduction at brake disc rotor surface played a major influence on the stress. As a comparison, the maximum stress and strain of Al-MMCs brake disc was lower than that induced on the cast iron brake disc.

  20. Holographic optical disc

    NASA Astrophysics Data System (ADS)

    Zhou, Gan; An, Xin; Pu, Allen; Psaltis, Demetri; Mok, Fai H.

    1999-11-01

    The holographic disc is a high capacity, disk-based data storage device that can provide the performance for next generation mass data storage needs. With a projected capacity approaching 1 terabit on a single 12 cm platter, the holographic disc has the potential to become a highly efficient storage hardware for data warehousing applications. The high readout rate of holographic disc makes it especially suitable for generating multiple, high bandwidth data streams such as required for network server computers. Multimedia applications such as interactive video and HDTV can also potentially benefit from the high capacity and fast data access of holographic memory.

  1. Immunohistochemistry for Pathologists: Protocols, Pitfalls, and Tips

    PubMed Central

    Kim, So-Woon; Roh, Jin; Park, Chan-Sik

    2016-01-01

    Immunohistochemistry (IHC) is an important auxiliary method for pathologists in routine diagnostic work as well as in basic and clinical research including exploration of biomarkers, as IHC allows confirmation of target molecule expressions in the context of microenvironment. Although there has been a considerable progress in automation and standardization of IHC, there are still many things to be considered in proper optimization and appropriate interpretation. In this review, we aim to provide possible pitfalls and useful tips for practicing pathologists and residents in pathology training. First, general procedure of IHC is summarized, followed by pitfalls and tips in each step and a summary of troubleshooting. Second, ways to an accurate interpretation of IHC are discussed, with introduction to general quantification and analysis methods. This review is not intended to provide complete information on IHC, but to be used as a basic reference for practice and publication. PMID:27809448

  2. Shoulder replacement

    MedlinePlus

    ... the opening at the end of the shoulder blade, called the socket. This type of joint allows ... head. The socket part (glenoid) of your shoulder blade will be replaced with a smooth plastic shell ( ...

  3. Pitfalls of predicting complex traits from SNPs

    PubMed Central

    Wray, Naomi R.; Yang, Jian; Hayes, Ben J.; Price, Alkes L.; Goddard, Mike E.; Visscher, Peter M.

    2014-01-01

    The success of genome-wide association studies has led to increasing interest in making predictions of complex trait phenotypes including disease from genotype data. Rigorous assessment of the value of predictors is critical before implementation. Here we discuss some of the limitations and pitfalls of prediction analysis and show how naïve implementations can lead to severe bias and misinterpretation of results. PMID:23774735

  4. Condylar osteochondroma treated with total condylectomy and preservation of the articular disc: a case report.

    PubMed

    Dominguez, Manuel Fernandez; Castillo, Jose Luis Del; Guerra, Mario Muñoz; Sanchez, Ruth Sanchez; La Plata, Maria Mancha De

    2015-06-01

    Osteochondroma is frequently found in the general skeleton but is rare in the condylar region of the mandible. We report a case of an osteochondroma of large size and rapid growth in the mandibular condyle, which was treated with total condylectomy and condylar replacement with a costochondral graft and preservation of the articular disc. In cases with a healthy and well-positioned articular disc, it may be preserved with no need of disc repositioning.

  5. Hip Replacement

    MedlinePlus

    ... cemented and uncemented prostheses are comparable. However, more long-term data are available in the United States for hip replacements with cemented prostheses, because doctors have been using them ... period. Because it takes a long time for the natural bone to grow and ...

  6. The origin of thick discs

    NASA Astrophysics Data System (ADS)

    Comerón, Sébastien

    2015-03-01

    Thick discs are defined to be disc-like components with a scale height larger than that of the classical discs. They are ubiquitous (Yoachim & Dalcanton 2006; Comerón et al. 2011a), they are made of mostly old and metal-poor stars and are most easily detected in close to edge-on galaxies. Their origin has been considered mysterious and several formation theories have been proposed: • The thick disc being formed secularly by thin disc stars heated by disc overdensities such as giant molecular clouds or spiral arms (Villumsen 1985, ApJ, 290, 75) and by stars moved outwards from their original orbits by radial migration mechanisms (Schönrich & Binney 2009). • The thick disc being formed by the heating of the thin disc by satellites (Quinn et al. 1993) and the tidal stripping of them (Abadi et al. 2003). • The thick disc being formed fast and already thick at high redshift in an highly unstable disc. Inside that thick disc, a thin disc would form afterwards as suggested by Elemgreen & Elmegreen (2006). • The thick disc being formed originally thick at high redshift by the merger of gas-rich protogalactic fragments and a thin disc forming afterwards within it (Brook et al. 2007). The first mechanism is a secular evolution mechanism. The time-scale of the second one is dependent on the merger history of the main galaxy. In the two last mechanisms, the thick disc forms already thick in a short time-scale at high redshift. Recent Milky Way studies, (see, e.g., Bovy et al. 2012), have shown indications that there is no discontinuity between the thin and the thick disc chemical and kinematic properties. Instead, those studies indicate the presence of a monotonic distribution of disc thicknesses. This would suggest a secular origin for the Milky Way thick disc. Studies in external galaxies (Yoachim & Dalcanton 2006; Comerón et al. 2011b), have shown that low-mass disc galaxies have thick disc relative masses much larger than those found in large-mass galaxies

  7. Pitfalls of Personal Development Plans--The User Perspective

    ERIC Educational Resources Information Center

    Grohnert, Therese; Beausaert, Simon; Segers, Mien

    2014-01-01

    This study was conducted to investigate which pitfalls users of personal development plans (PDPs) perceive in business and governmental organisations with mandatory PDP use. Hundred and thirty-one written statements of PDP users across three Dutch organisations were analysed and categorised into nine pitfalls. Next to an overall lack of use and…

  8. Pitfalls in colour photography of choroidal tumours.

    PubMed

    Schalenbourg, A; Zografos, L

    2013-02-01

    Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown.

  9. Pitfalls and variants in pediatric chest imaging.

    PubMed

    García Asensio, D; Fernández Martín, M

    2016-05-01

    Most pitfalls in the interpretation of pediatric chest imaging are closely related with the technique used and the characteristics of pediatric patients. To obtain a quality image that will enable the correct diagnosis, it is very important to use an appropriate technique. It is important to know how technical factors influence the image and to be aware of the possible artifacts that can result from poor patient cooperation. Moreover, radiologists need to be familiar with the normal anatomy in children, with the classic radiologic findings, and with the anatomic and developmental variants to avoid misinterpreting normal findings as pathological.

  10. The Galactic stellar disc

    NASA Astrophysics Data System (ADS)

    Feltzing, S.; Bensby, T.

    2008-12-01

    The study of the Milky Way stellar discs in the context of galaxy formation is discussed. In particular, we explore the properties of the Milky Way disc using a new sample of about 550 dwarf stars for which we have recently obtained elemental abundances and ages based on high-resolution spectroscopy. For all the stars we also have full kinematic information as well as information about their stellar orbits. We confirm results from previous studies that the thin and the thick discs have distinct abundance patterns. But we also explore a larger range of orbital parameters than what has been possible in our previous studies. Several new results are presented. We find that stars that reach high above the Galactic plane and have eccentric orbits show remarkably tight abundance trends. This implies that these stars formed out of well-mixed gas that had been homogenized over large volumes. We find some evidence that suggest that the event that most likely caused the heating of this stellar population happened a few billion years ago. Through a simple, kinematic exploration of stars with super-solar [Fe/H], we show that the solar neighbourhood contains metal-rich, high velocity stars that are very likely associated with the thick disc. Additionally, the HR1614 moving group and the Hercules and Arcturus stellar streams are discussed and it is concluded that, probably, a large fraction of the groups and streams so far identified in the disc are the result of evolution and interactions within the stellar disc rather than being dissolved stellar clusters or engulfed dwarf galaxies. This paper includes data gathered with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile. Also based on observations collected at the Nordic Optical Telescope on La Palma, Spain, and at the European Southern Observatories on La Silla and Paranal, Chile, Proposals no. 65.L-0019(B), 67.B-0108(B), 69.B-0277.

  11. Cervical disc arthroplasty: Pros and cons

    PubMed Central

    Moatz, Bradley; Tortolani, P. Justin

    2012-01-01

    Background: Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. Methods: This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Results: Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Conclusion: Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing. PMID:22905327

  12. How do accretion discs break?

    NASA Astrophysics Data System (ADS)

    Dogan, Suzan

    2016-07-01

    Accretion discs are common in binary systems, and they are often found to be misaligned with respect to the binary orbit. The gravitational torque from a companion induces nodal precession in misaligned disc orbits. In this study, we first calculate whether this precession is strong enough to overcome the internal disc torques communicating angular momentum. We compare the disc precession torque with the disc viscous torque to determine whether the disc should warp or break. For typical parameters precession wins: the disc breaks into distinct planes that precess effectively independently. To check our analytical findings, we perform 3D hydrodynamical numerical simulations using the PHANTOM smoothed particle hydrodynamics code, and confirm that disc breaking is widespread and enhances accretion on to the central object. For some inclinations, the disc goes through strong Kozai cycles. Disc breaking promotes markedly enhanced and variable accretion and potentially produces high-energy particles or radiation through shocks. This would have significant implications for all binary systems: e.g. accretion outbursts in X-ray binaries and fuelling supermassive black hole (SMBH) binaries. The behaviour we have discussed in this work is relevant to a variety of astrophysical systems, for example X-ray binaries, where the disc plane may be tilted by radiation warping, SMBH binaries, where accretion of misaligned gas can create effectively random inclinations and protostellar binaries, where a disc may be misaligned by a variety of effects such as binary capture/exchange, accretion after binary formation.

  13. Revival of the Jumping Disc

    ERIC Educational Resources Information Center

    Ucke, C.; Schlichting, H-J.

    2009-01-01

    Snap discs made of bimetal have many technical applications as thermostats. Jumping discs are a toy version of such snap discs. Besides giving technical information, we describe physical investigations. We show especially how, through simple measurements and calculations, you can determine the initial speed ([approximately equal to]3.5 m…

  14. Hybrid cervical disc arthroplasty.

    PubMed

    Tu, Tsung-Hsi; Wu, Jau-Ching; Cheng, Henrich; Mummaneni, Praveen V

    2017-01-01

    For patients with multilevel cervical stenosis at nonadjacent segments, one of the traditional approaches has included a multilevel fusion of the abnormal segments as well as the intervening normal segment. In this video we demonstrate an alternative treatment plan with tailored use of a combination of anterior cervical discectomy and fusion (ACDF) and cervical disc arthroplasty (CDA) with an intervening skipped level. The authors present the case of a 72-year-old woman with myeloradiculopathy and a large disc herniation with facet joint degeneration at C3-4 and bulging disc at C5-6. After nonoperative treatment failed, she underwent a single-level ACDF at C3-4 and single-level arthroplasty at C5-6, which successfully relieved her symptoms. No intervention was performed at the normal intervening C4-5 segment. By using ACDF combined with arthroplasty, the authors have avoided a 3-level fusion for this patient and maintained the range of motion of 2 disc levels. The video can be found here: https://youtu.be/OrxcPUBvqLk .

  15. The Teddy Bears' Disc.

    ERIC Educational Resources Information Center

    Laurillard, Diana

    1985-01-01

    Reports an evaluation of the Teddy Bear disc, an interactive videodisc developed at the Open University for a second-level course in metallurgy and materials technology. Findings from observation of students utilizing the videodisc are reviewed; successful design features and design problems are considered; and development costs are outlined. (MBR)

  16. ISASS Policy Statement – Lumbar Artificial Disc

    PubMed Central

    Garcia, Rolando

    2015-01-01

    Purpose The primary goal of this Policy Statement is to educate patients, physicians, medical providers, reviewers, adjustors, case managers, insurers, and all others involved or affected by insurance coverage decisions regarding lumbar disc replacement surgery. Procedures This Policy Statement was developed by a panel of physicians selected by the Board of Directors of ISASS for their expertise and experience with lumbar TDR. The panel's recommendation was entirely based on the best evidence-based scientific research available regarding the safety and effectiveness of lumbar TDR. PMID:25785243

  17. Writing midwives' history: problems and pitfalls.

    PubMed

    Allotey, Janette C

    2011-04-01

    As more midwives are becoming interested in the history of midwifery and carrying out historical research, it is opportune to consider some of the problems and pitfalls of this approach. The study and writing of history initially involves the collection of evidence, followed by its critical analysis and interpretation. The scarcity and reliability of sources poses the first problem. Even with the greatest of insight, it is impossible to fully reconstruct the past and eliminate bias. Evidence is open to manipulation and distortion, affecting the way in which findings are presented to a readership. This paper, aimed at novice researchers in the field, focuses on some of the fundamental principles of good research, and contains examples of ways in which the past may be misinterpreted or changed. The nature and construction of professional knowledge will also be briefly examined to establish whether objectivity is possible within historical research.

  18. The EXIT procedure: principles, pitfalls, and progress.

    PubMed

    Marwan, Ahmad; Crombleholme, Timothy M

    2006-05-01

    Although performing procedures on a fetus before severing the umbilical cord has previously been reported, the principles of the ex utero intrapartum treatment (EXIT) procedure were first fully developed for reversing tracheal occlusion in fetuses with severe congenital diaphragmatic hernia. The EXIT procedure offers the advantage of insuring uteroplacental gas exchange while on placental support. The lessons learned in the development of the principles that underlie the EXIT procedure have improved outcomes when applied in other conditions, most notably in cases of airway obstruction. The range of indications for the EXIT procedure has expanded and currently includes giant fetal neck masses, lung or mediastinal tumors, congenital high airway obstruction syndrome, and EXIT to ECMO (extracorporeal membrane oxygenation), among others. This review summarizes the underlying principles of the EXIT procedure, the expanding indications for its use, the pitfalls of management, and the progress that has been made in its successful application.

  19. Arrhythmogenic cardiomyopathy: a disease of intercalated discs.

    PubMed

    Calore, Martina; Lorenzon, Alessandra; De Bortoli, Marzia; Poloni, Giulia; Rampazzo, Alessandra

    2015-06-01

    Arrhythmogenic cardiomyopathy (ACM) is an acquired progressive disease having an age-related penetrance and showing clinical manifestations usually during adolescence and young adulthood. It is characterized clinically by a high incidence of severe ventricular tachyarrhythmias and sudden cardiac death and pathologically by degeneration of ventricular cardiomyocytes with replacement by fibro-fatty tissue. Whereas, in the past, the disease was considered to involve only the right ventricle, more recent clinical studies have established that the left ventricle is frequently involved. ACM is an inherited disease in up to 50% of cases, with predominantly an autosomal dominant pattern of transmission, although recessive inheritance has also been described. Since most of the pathogenic mutations have been identified in genes encoding desmosomal proteins, ACM is currently defined as a disease of desmosomes. However, on the basis of the most recent description of the intercalated disc organization and of the identification of a novel ACM gene encoding for an area composita protein, ACM can be considered as a disease of the intercalated disc, rather than only as a desmosomal disease. Despite increasing knowledge of the genetic basis of ACM, we are just beginning to understand early molecular events leading to cardiomyocyte degeneration, fibrosis and fibro-fatty substitution. This review summarizes recent advances in our comprehension of the link between the molecular genetics and pathogenesis of ACM and of the novel role of cardiac intercalated discs.

  20. LUMBAR DISC HERNIATION

    PubMed Central

    Vialle, Luis Roberto; Vialle, Emiliano Neves; Suárez Henao, Juan Esteban; Giraldo, Gustavo

    2015-01-01

    Lumbar disc herniation is the most common diagnosis among the degenerative abnormalities of the lumbar spine (affecting 2 to 3% of the population), and is the principal cause of spinal surgery among the adult population. The typical clinical picture includes initial lumbalgia, followed by progressive sciatica. The natural history of disc herniation is one of rapid resolution of the symptoms (four to six weeks). The initial treatment should be conservative, managed through medication and physiotherapy, sometimes associated with percutaneous nerve root block. Surgical treatment is indicated if pain control is unsuccessful, if there is a motor deficit greater than grade 3, if there is radicular pain associated with foraminal stenosis, or if cauda equina syndrome is present. The latter represents a medical emergency. A refined surgical technique, with removal of the extruded fragment and preservation of the ligamentum flavum, resolves the sciatic symptoms and reduces the risk of recurrence over the long term. PMID:27019834

  1. Biomechanics of Disc Degeneration

    PubMed Central

    Palepu, V.; Kodigudla, M.; Goel, V. K.

    2012-01-01

    Disc degeneration and associated disorders are among the most debated topics in the orthopedic literature over the past few decades. These may be attributed to interrelated mechanical, biochemical, and environmental factors. The treatment options vary from conservative approaches to surgery, depending on the severity of degeneration and response to conservative therapies. Spinal fusion is considered to be the “gold standard” in surgical methods till date. However, the association of adjacent level degeneration has led to the evolution of motion preservation technologies like spinal arthroplasty and posterior dynamic stabilization systems. These new technologies are aimed to address pain and preserve motion while maintaining a proper load sharing among various spinal elements. This paper provides an elaborative biomechanical review of the technologies aimed to address the disc degeneration and reiterates the point that biomechanical efficacy followed by long-term clinical success will allow these nonfusion technologies as alternatives to fusion, at least in certain patient population. PMID:22745914

  2. Mechanotransduction in intervertebral discs

    PubMed Central

    Tsai, Tsung-Ting; Cheng, Chao-Min; Chen, Chien-Fu; Lai, Po-Liang

    2014-01-01

    Mechanotransduction plays a critical role in intracellular functioning—it allows cells to translate external physical forces into internal biochemical activities, thereby affecting processes ranging from proliferation and apoptosis to gene expression and protein synthesis in a complex web of interactions and reactions. Accordingly, aberrant mechanotransduction can either lead to, or be a result of, a variety of diseases or degenerative states. In this review, we provide an overview of mechanotransduction in the context of intervertebral discs, with a focus on the latest methods of investigating mechanotransduction and the most recent findings regarding the means and effects of mechanotransduction in healthy and degenerative discs. We also provide some discussion of potential directions for future research and treatments. PMID:25267492

  3. Mechanics of Actuated Disc Cutting

    NASA Astrophysics Data System (ADS)

    Dehkhoda, Sevda; Detournay, Emmanuel

    2017-02-01

    This paper investigates the mechanics of an actuated disc cutter with the objective of determining the average forces acting on the disc as a function of the parameters characterizing its motion. The specific problem considered is that of a disc cutter revolving off-centrically at constant angular velocity around a secondary axis rigidly attached to a cartridge, which is moving at constant velocity and undercutting rock at a constant depth. This model represents an idealization of a technology that has been implemented in a number of hard rock mechanical excavators with the goal of reducing the average thrust force to be provided by the excavation equipment. By assuming perfect conformance of the rock with the actuated disc as well as a prescribed motion of the disc (perfectly rigid machine), the evolution of the contact surface between the disc and the rock during one actuation of the disc can be computed. Coupled with simple cutter/rock interaction models that embody either a ductile or a brittle mode of fragmentation, these kinematical considerations lead to an estimate of the average force on the cartridge and of the partitioning of the energy imparted by the disc to the rock between the actuation mechanism of the disc and the translation of the cartridge on which the actuated disc is attached.

  4. Polarimetric microlensing of circumstellar discs

    NASA Astrophysics Data System (ADS)

    Sajadian, Sedighe; Rahvar, Sohrab

    2015-12-01

    We study the benefits of polarimetry observations of microlensing events to detect and characterize circumstellar discs around the microlensed stars located at the Galactic bulge. These discs which are unresolvable from their host stars make a net polarization effect due to their projected elliptical shapes. Gravitational microlensing can magnify these signals and make them be resolved. The main aim of this work is to determine what extra information about these discs can be extracted from polarimetry observations of microlensing events in addition to those given by photometry ones. Hot discs which are closer to their host stars are more likely to be detected by microlensing, owing to more contributions in the total flux. By considering this kind of discs, we show that although the polarimetric efficiency for detecting discs is similar to the photometric observation, but polarimetry observations can help to constraint the disc geometrical parameters e.g. the disc inner radius and the lens trajectory with respect to the disc semimajor axis. On the other hand, the time-scale of polarimetric curves of these microlensing events generally increases while their photometric time-scale does not change. By performing a Monte Carlo simulation, we show that almost four optically thin discs around the Galactic bulge sources are detected (or even characterized) through photometry (or polarimetry) observations of high-magnification microlensing events during 10-yr monitoring of 150 million objects.

  5. Teaching Child Development Via the Internet: Opportunities and Pitfalls.

    ERIC Educational Resources Information Center

    Graham, Theresa A.

    2001-01-01

    Describes the development and implementation of a cross-listed undergraduate and graduate-level child psychology course taught over the Internet. Describes course content and instructional goals. Outlines the opportunities and pitfalls of teaching in a virtual classroom. (CMK)

  6. Androgens and doping tests: genetic variation and pit-falls

    PubMed Central

    Rane, Anders; Ekström, Lena

    2012-01-01

    The large variation in disposition known for most drugs is also true for anabolic androgenic steroids. Genetic factors are probably the single most important cause of this variation. Further, there are reasons to believe that there is a corresponding variation in efficacy of doping agents. Doped individuals employ a large variety of doping strategies in respect of choice of substance, dose, dose interval, duration of treatment and use of other drugs for enforcement of effects or correction of side effects. Metabolic steps up-stream and down-stream of testosterone are genetically variable and contribute substantially to the variation in disposition of testosterone, the most common doping agent in sports and in society. Large inter- and intra-ethnic variation in testosterone glucuronidation and excretion is described as well as the pit-falls in evaluation of testosterone doping test results. The hydrolysis and bioactivation of testosterone enanthate is also genetically variable yielding a 2–3 fold variation in excretion rate and serum concentration, thereby implicating a substantial variation in ‘efficacy’ of testosterone. Given this situation it is logical to adopt the new findings in the doping control programme. The population based cut-off level for the testosterone : epitestosterone ratio should be replaced by a Bayesian interpretation of consecutive tests in the same individual. When combined with the above genetic information the sensitivity of the test is considerably improved. The combination of the three approaches should reduce the rate of falsely negative or positive results and the number of expensive follow-up tests, stipulated by the World Anti-Doping Agency. PMID:22506612

  7. Rethinking Black Hole Accretion Discs

    NASA Astrophysics Data System (ADS)

    Salvesen, Greg

    Accretion discs are staples of astrophysics. Tapping into the gravitational potential energy of the accreting material, these discs are highly efficient machines that produce copious radiation and extreme outflows. While interesting in their own right, accretion discs also act as tools to study black holes and directly influence the properties of the Universe. Black hole X-ray binaries are fantastic natural laboratories for studying accretion disc physics and black hole phenomena. Among many of the curious behaviors exhibited by these systems are black hole state transitions -- complicated cycles of dramatic brightening and dimming. Using X-ray observations with high temporal cadence, we show that the evolution of the accretion disc spectrum during black hole state transitions can be described by a variable disc atmospheric structure without invoking a radially truncated disc geometry. The accretion disc spectrum can be a powerful diagnostic for measuring black hole spin if the effects of the disc atmosphere on the emergent spectrum are well-understood; however, properties of the disc atmosphere are largely unconstrained. Using statistical methods, we decompose this black hole spin measurement technique and show that modest uncertainties regarding the disc atmosphere can lead to erroneous spin measurements. The vertical structure of the disc is difficult to constrain due to our ignorance of the contribution to hydrostatic balance by magnetic fields, which are fundamental to the accretion process. Observations of black hole X-ray binaries and the accretion environments near supermassive black holes provide mounting evidence for strong magnetization. Performing numerical simulations of accretion discs in the shearing box approximation, we impose a net vertical magnetic flux that allows us to effectively control the level of disc magnetization. We study how dynamo activity and the properties of turbulence driven by the magnetorotational instability depend on the

  8. Heat distribution in disc brake

    NASA Astrophysics Data System (ADS)

    Klimenda, Frantisek; Soukup, Josef; Kampo, Jan

    2016-06-01

    This article is deals by the thermal analysis of the disc brake with floating caliper. The issue is solved by numerically. The half 2D model is used for solution in program ADINA 8.8. Two brake discs without the ventilation are solved. One disc is made from cast iron and the second is made from stainless steel. Both materials are an isotropic. By acting the pressure force on the brake pads will be pressing the pads to the brake disc. Speed will be reduced (slowing down). On the contact surface generates the heat, which the disc and pads heats. In the next part of article is comparison the maximum temperature at the time of braking. The temperatures of both materials for brake disc (gray cast iron, stainless steel) are compares. The heat flux during braking for the both materials is shown.

  9. Enclosed rotary disc air pulser

    DOEpatents

    Olson, A. L.; Batcheller, Tom A.; Rindfleisch, J. A.; Morgan, John M.

    1989-01-01

    An enclosed rotary disc air pulser for use with a solvent extraction pulse olumn includes a housing having inlet, exhaust and pulse leg ports, a shaft mounted in the housing and adapted for axial rotation therein, first and second disc members secured to the shaft within the housing in spaced relation to each other to define a chamber therebetween, the chamber being in communication with the pulse leg port, the first disc member located adjacent the inlet port, the second disc member being located adjacent the exhaust port, each disc member having a milled out portion, the disc members positioned on the shaft so that as the shaft rotates, the milled out portions permit alternative cyclical communication between the inlet port and the chamber and the exhaust port and the chamber.

  10. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    PubMed Central

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration − the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval − the activL® Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. PMID:27274317

  11. The activL(®) Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain.

    PubMed

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration - the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval - the activL(®) Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL(®) Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL(®) Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL(®) Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date.

  12. Preparation of ormetoprim sulfadimethoxine medicated discs for disc diffusion assay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Romet (a blend of ormetoprim and sulfadimethoxine) is a typeA medicated article for the manufacture of medicated feed in the catfish industry. Recently, the commercial manufacture of ormetoprim–sulfadimethoxine susceptibility discs was discontinued. Ormetoprim–sulfadimethoxine discs were prepared at...

  13. Sizes of protoplanetary discs after star-disc encounters

    NASA Astrophysics Data System (ADS)

    Breslau, Andreas; Steinhausen, Manuel; Vincke, Kirsten; Pfalzner, Susanne

    2014-05-01

    Most stars do not form in isolation, but as part of a star cluster or association. These young stars are initially surrounded by protoplanetary discs. In these cluster environments tidal interactions with other cluster members can alter the disc properties. Besides the disc frequency, its mass, angular momentum, and energy, the disc's size is particularly prone to being changed by a passing star. So far the change in disc size has only been investigated for a small number of very specific encounters. Several studies investigated the effect of the cluster environment on the sizes of planetary systems like our own solar system, based on a generalisation of information from this limited sample. We performed numerical simulations covering the wide parameter space typical of young star clusters, to test the validity of this approach. Here the sizes of discs after encounters are presented, based on a size definition that is comparable to the one used in observational studies. We find that, except for encounters between equal-mass stars, the usually applied estimates are insufficient. They tend to severely overestimate the remaining disc size. We show that the disc size after an encounter can be described by a relatively simple dependence on the periastron distance and the mass ratio of the encounter partners. This knowledge allows us, for example, to pin down the types of encounter possibly responsible for the structure of today's solar system. Appendix A is available in electronic form at http://www.aanda.org

  14. Avoiding numerical pitfalls in social force models

    NASA Astrophysics Data System (ADS)

    Köster, Gerta; Treml, Franz; Gödel, Marion

    2013-06-01

    The social force model of Helbing and Molnár is one of the best known approaches to simulate pedestrian motion, a collective phenomenon with nonlinear dynamics. It is based on the idea that the Newtonian laws of motion mostly carry over to pedestrian motion so that human trajectories can be computed by solving a set of ordinary differential equations for velocity and acceleration. The beauty and simplicity of this ansatz are strong reasons for its wide spread. However, the numerical implementation is not without pitfalls. Oscillations, collisions, and instabilities occur even for very small step sizes. Classic solution ideas from molecular dynamics do not apply to the problem because the system is not Hamiltonian despite its source of inspiration. Looking at the model through the eyes of a mathematician, however, we realize that the right hand side of the differential equation is nondifferentiable and even discontinuous at critical locations. This produces undesirable behavior in the exact solution and, at best, severe loss of accuracy in efficient numerical schemes even in short range simulations. We suggest a very simple mollified version of the social force model that conserves the desired dynamic properties of the original many-body system but elegantly and cost efficiently resolves several of the issues concerning stability and numerical resolution.

  15. Imaginal disc regeneration takes flight.

    PubMed

    Hariharan, Iswar K; Serras, Florenci

    2017-04-01

    Drosophila imaginal discs, the larval precursors of adult structures such as the wing and leg, are capable of regenerating after damage. During the course of regeneration, discs can sometimes generate structures that are appropriate for a different type of disc, a phenomenon termed transdetermination. Until recently, these phenomena were studied by physically fragmenting discs and then transplanting them into the abdomens of adult female flies. This field has experienced a renaissance following the development of genetic ablation systems that can damage precisely defined regions of the disc without the need for surgery. Together with more traditional approaches, these newer methods have generated many novel insights into wound healing, the mechanisms that drive regenerative growth, plasticity during regeneration and systemic effects of tissue damage and regeneration.

  16. Intraoral micro-identification discs.

    PubMed

    Hansen, R W

    1991-12-01

    Intraoral micro-identification discs have recently been utilized to provide a more permanent method of personal identification. A wafer of plastic or metal with a surface area of 2.5 to 5 mm2 and carrying identifying numbers and/or letters (indicia) is bonded to the buccal enamel surface of the posterior teeth. Personal identification can occur after the I.D. disc is identified and the indicia is read. Reading of photoreduced indicia requires the aid of a microscope subsequent to the removal of the microdisc. In situ reading of disc indicia is possible using low power handheld magnifiers if the size of the indicia approximates 0.3 mm. Computerization is an integral part of non-custom alpha/numeric type designs, but a custom disc carries a name, address, and other specific information unique to the manufacturer. The use of a computer improves access to the database and it decreases the amount of data placed on the disc. Microdisc bases may be fabricated using a mylar type plastic or they may be manufactured from a stainless steel blank. Plastic discs are constructed with an internal sandwich containing the photo-reduced indicia. Metal discs are marked with a photochemical etch or engraved with a computer driven YAG laser. Attachment of the disc to the enamel surface is accomplished by conventional etching and bonding techniques and are typically bonded to the buccal surface of the maxillary first permanent molar or the second primary molar. Clear composite bonding material covers the disc so that salivary contamination does not result in degradation of the indicia. Orthodontic style discs with a mesh back carry laser written information that may be cemented with conventional orthodontic bonding cement. Standardization of the indicia and overall design is considered to be an important aspect of patient and professional acceptance.

  17. Cervical Total Disc Arthroplasty

    PubMed Central

    Basho, Rahul; Hood, Kenneth A.

    2012-01-01

    Symptomatic adjacent segment degeneration of the cervical spine remains problematic for patients and surgeons alike. Despite advances in surgical techniques and instrumentation, the solution remains elusive. Spurred by the success of total joint arthroplasty in hips and knees, surgeons and industry have turned to motion preservation devices in the cervical spine. By preserving motion at the diseased level, the hope is that adjacent segment degeneration can be prevented. Multiple cervical disc arthroplasty devices have come onto the market and completed Food and Drug Administration Investigational Device Exemption trials. Though some of the early results demonstrate equivalency of arthroplasty to fusion, compelling evidence of benefits in terms of symptomatic adjacent segment degeneration are lacking. In addition, non-industry-sponsored studies indicate that these devices are equivalent to fusion in terms of adjacent segment degeneration. Longer-term studies will eventually provide the definitive answer. PMID:24353955

  18. Pitfalls and Limitations of Radionuclide and Hybrid Imaging in Infection and Inflammation.

    PubMed

    Glaudemans, Andor W J M; Israel, Ora; Slart, Riemer H J A

    2015-11-01

    Both the referring clinician and the nuclear medicine specialist must be aware of the main known or potential pitfalls that can occur in infection and inflammation imaging. They must decide in consensus which tracer and which imaging protocol should be used for a specific indication. This article provides an overview of all the pitfalls and limitations of nuclear medicine techniques to image infections and inflammation. Both general pitfalls and pitfalls in specific clinical entities are discussed.

  19. Avoiding pitfalls when implementing local area networks in hospital environments.

    PubMed

    Kaudewitz, G; Schulte, A

    1995-01-01

    This paper is intended to outline some of the most commonly encountered, but yet still underestimated pitfalls during the implementation of computer systems networks in hospitals and health care institutions and to give information technology planners and responsibles some practical hints for avoiding them. Pitfalls encountered during the difficult process of achieving consensus among all groups concerned on the necessity for electronic data processing in health care institutions will not be addressed here [1], though the authors believe that some major risks for project failure stem from shortcomings in this field. Instead, those pitfalls encountered during project initialization and project realization with the phases of analysis, design, contracting, installation, and maintenance will be discussed. The paper concludes with the authors' opinion that only the application of industry-proven project management and realization techniques will allow health care administrators to cope with the steadily increasing risks for failure of information technology projects in health care.

  20. Double-disc gate valve

    DOEpatents

    Wheatley, Seth J.

    1979-01-01

    This invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewtih, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separtion of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve.

  1. How to avoid the ten most frequent EMS pitfalls

    SciTech Connect

    Andrews, W.

    1982-04-19

    It pays to do your homework before investing in an energy management system if you want to avoid the 10 most common pitfalls listed by users, consultants, and manufacturers as: oversimplification, improper maintenance, failure to involve operating personnel, inaccurate savings estimates, failure to include monitoring capability, incompetent or fradulent firms, improper load control, not allowing for a de-bugging period, failure to include manual override, and software problems. The article describes how each of these pitfalls can lead to poor decisions and poor results. (DCK)

  2. Rational manipulation of digital EEG: pearls and pitfalls.

    PubMed

    Seneviratne, Udaya

    2014-12-01

    The advent of digital EEG has provided greater flexibility and more opportunities in data analysis to optimize the diagnostic yield. Changing the filter settings, sensitivity, montages, and time-base are possible rational manipulations to achieve this goal. The options to use polygraphy, video, and quantification are additional useful features. Aliasing and loss of data are potential pitfalls in the use of digital EEG. This review illustrates some common clinical scenarios where rational manipulations can enhance the diagnostic EEG yield and potential pitfalls in the process.

  3. Pitfalls and Limitations of Radionuclide Renal Imaging in Pediatrics.

    PubMed

    Biassoni, Lorenzo

    2015-09-01

    The article presents common pitfalls encountered in pediatric radionuclide renography, illustrated with clinical cases. It is important to recognize normal variants. A good acquisition technique is essential. Correlation with other imaging techniques, with the clinical background and symptoms, is critical. A clear clinical question is essential: based on the question and knowing the strengths and weaknesses of each test, the test which can best answer the question can be selected. Awareness of the pitfalls of radionuclide renography helps avoid errors of interpretation and allows the selection of the most helpful test for clinical management.

  4. Medical Information on Optical Disc*

    PubMed Central

    Schipma, Peter B.; Cichocki, Edward M.; Ziemer, Susan M.

    1987-01-01

    Optical discs may permit a revolutionary change in the distribution and use of medical information. A single compact disc, similar in size to that used for digital audio recording, can contain over 500 million characters of information that is accessible by a Personal Computer. These discs can be manufactured at a cost lower than that of print on paper, at reasonable volumes. Software can provide the health care professional with nearly instantaneous access to the information. Thus, for the first time, the opportunity exists to have large local medical information collections. This paper describes an application of this technology in the field of Oncology.

  5. Mitral disc-valve variance

    PubMed Central

    Berroya, Renato B.; Escano, Fernando B.

    1972-01-01

    This report deals with a rare complication of disc-valve prosthesis in the mitral area. A significant disc poppet and struts destruction of mitral Beall valve prostheses occurred 20 and 17 months after implantation. The resulting valve incompetence in the first case contributed to the death of the patient. The durability of Teflon prosthetic valves appears to be in question and this type of valve probably will be unacceptable if there is an increasing number of disc-valve variance in the future. Images PMID:5017573

  6. Operative Management of Lumbar Degenerative Disc Disease

    PubMed Central

    Lee, Yu Chao; Osti, Orso Lorenzo

    2016-01-01

    Lumbar degenerative disc disease is extremely common. Current evidence supports surgery in carefully selected patients who have failed non-operative treatment and do not exhibit any substantial psychosocial overlay. Fusion surgery employing the correct grafting and stabilization techniques has long-term results demonstrating successful clinical outcomes. However, the best approach for fusion remains debatable. There is some evidence supporting the more complex, technically demanding and higher risk interbody fusion techniques for the younger, active patients or patients with a higher risk of non-union. Lumbar disc arthroplasty and hybrid techniques are still relatively novel procedures despite promising short-term and mid-term outcomes. Long-term studies demonstrating superiority over fusion are required before these techniques may be recommended to replace fusion as the gold standard. Novel stem cell approaches combined with tissue engineering therapies continue to be developed in expectation of improving clinical outcomes. Results with appropriate follow-up are not yet available to indicate if such techniques are safe, cost-effective and reliable in the long-term. PMID:27559465

  7. Shoulder replacement - discharge

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000178.htm Shoulder replacement - discharge To use the sharing features on this page, please enable JavaScript. You had shoulder replacement surgery to replace the bones of your shoulder ...

  8. Knee joint replacement

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/002974.htm Knee joint replacement To use the sharing features on this page, please enable JavaScript. Knee joint replacement is a surgery to replace a knee ...

  9. Hip replacement - discharge

    MedlinePlus

    ... surgery to replace all or part of your hip joint with an artificial joint called a prosthesis. This ... You're in the Hospital You had a hip joint replacement surgery to replace all or part of ...

  10. Design Issues in Video Disc Map Display.

    DTIC Science & Technology

    1984-10-01

    Tables: disc storage capacities under various conditions. Photos: map frames. Constanzo , D.J. (1984a), "The Potential for Video Disc Technology in...discs. Constanzo , D.J. (1984b), "Requirements and Specifications for Cartographic Video Discs", presented as a poster paper at the 1984 Army Science

  11. Enlivening Physics, a Local Video Disc Project.

    ERIC Educational Resources Information Center

    McInerney, M.

    1989-01-01

    Describes how to make and use an inexpensive video disc of physics demonstrations. Discusses the background, production of the disc, subject of the disc including angular momentum, "monkey and the hunter" experiment, Doppler shift, pressure of a constant volume of gas thermometer, and wave effects, and using the disc in classroom. (YP)

  12. Disc Golf: Teaching a Lifetime Activity

    ERIC Educational Resources Information Center

    Eastham, Susan L.

    2015-01-01

    Disc golf is a lifetime activity that can be enjoyed by students of varying skill levels and abilities. Disc golf follows the principles of ball golf but is generally easier for students to play and enjoy success. The object of disc golf is similar to ball golf and involves throwing a disc from the teeing area to the target in as few throws as…

  13. Decellularized allogeneic intervertebral disc: natural biomaterials for regenerating disc degeneration

    PubMed Central

    Hu, Zhijun; Chen, Kai; Shan, Zhi; Chen, Shuai; Wang, Jiying; Mo, Jian; Ma, Jianjun; Xu, Wenbing; Qin, An; Fan, Shunwu

    2016-01-01

    Intervertebral disc degeneration is associated with back pain and disc herniation. This study established a modified protocol for intervertebral disc (IVD) decellularization and prepared its extracellular matrix (ECM). By culturing mesenchymal stem cells (MSCs)(3, 7, 14 and 21 days) and human degenerative IVD cells (7 days) in the ECM, implanting it subcutaneously in rabbit and injecting ECM microparticles into degenerative disc, the biological safety and efficacy of decellularized IVD was evaluated both in vitro and in vivo. Here, we demonstrated that cellular components can be removed completely after decellularization and maximally retain the structure and biomechanics of native IVD. We revealed that allogeneic ECM did not evoke any apparent inflammatory reaction in vivo and no cytotoxicity was found in vitro. Moreover, IVD ECM can induce differentiation of MSCs into IVD-like cells in vitro. Furthermore, allogeneic ECM microparticles are effective on the treatment of rabbit disc degeneration in vivo. In conclusion, our study developed an optimized method for IVD decellularization and we proved decellularized IVD is safe and effective for the treatment of degenerated disc diseases. PMID:26933821

  14. Eclipse Mapping of Accretion Discs

    NASA Astrophysics Data System (ADS)

    Baptista, R.

    The eclipse mapping method is an inversion technique that makes use of the information contained in eclipse light curves to probe the structure, the spectrum and the time evolution of accretion discs. In this review I present the basics of the method and discuss its different implementations. I summarize the most important results obtained to date and discuss how they have helped to improve our understanding of accretion physics, from testing the theoretical radial brightness temperature distribution and measuring mass accretion rates to showing the evolution of the structure of a dwarf novae disc throughout its outburst cycle, from isolating the spectrum of a disc wind to revealing the geometry of disc spiral shocks. I end with an outline of the future prospects.

  15. Tissue engineering: A live disc

    NASA Astrophysics Data System (ADS)

    Hukins, David W. L.

    2005-12-01

    A material-cell hybrid device that mimics the anatomic shape of the intervertebral disc has been made and successfully implanted into mice to show that tissue engineering may, in the future, benefit sufferers from back pain.

  16. Disc Golf, a Growing Sport

    PubMed Central

    Nelson, Joseph T.; Jones, Richard E.; Runstrom, Michael; Hardy, Jolene

    2015-01-01

    Background Disc golf is a sport played much like traditional golf, but rather than using a ball and club, players throw flying discs with various throwing motions. It has been played by an estimated 8 to 12 million people in the United States. Like all sports, injuries sustained while playing disc golf are not uncommon. Although formalized in the 1970s, it has grown at a rapid pace; however, disc golf–related injuries have yet to be described in the medical literature. Purpose To describe the most common injuries incurred by disc golf players while comparing the different types of throwing styles. Study Design Descriptive epidemiology study. Methods The data in this study were collected from 883 disc golf players who responded to an online survey collected over a 1-month period. Respondents answered 49 questions related to demographics, experience, style of play, and injury details. Using a chi-square analysis, common injuries sustained in players using backhand and forehand throwing styles were compared. Results More than 81% of respondents stated that they had sustained an injury playing disc golf, including injuries to the elbow (n = 325), shoulder (n = 305), back (n = 218), and knee (n = 199). The injuries were most commonly described as a muscle strain (n = 241), sprain (n = 162), and tendinitis (n = 145). The type of throw primarily used by players varied, with 86.2% using backhand, 12.7% using forehand, and 1.1% using an overhead throw. Players using a forehand throw were more likely to sustain an elbow injury (P = .014). Many players (n = 115) stated they had undergone surgery due to a disc golf–related injury, with the most common surgeries including meniscal, shoulder, spine, and foot/ankle surgeries. Conclusion The majority of surveyed disc golfers sustained at least 1 injury while playing disc golf, with many requiring surgery. The types of injuries sustained by players varied by the types of throw primarily used. As the sport of disc golf continues

  17. Percutaneous diode laser disc nucleoplasty

    NASA Astrophysics Data System (ADS)

    Menchetti, P. P.; Longo, Leonardo

    2004-09-01

    The treatment of herniated disc disease (HNP) over the years involved different miniinvasive surgical options. The classical microsurgical approach has been substituted over the years both by endoscopic approach in which is possible to practice via endoscopy a laser thermo-discoplasty, both by percutaneous laser disc nucleoplasty. In the last ten years, the percutaneous laser disc nucleoplasty have been done worldwide in more than 40000 cases of HNP. Because water is the major component of the intervertebral disc, and in HNP pain is caused by the disc protrusion pressing against the nerve root, a 980 nm Diode laser introduced via a 22G needle under X-ray guidance and local anesthesia, vaporizes a small amount of nucleous polposus with a disc shrinkage and a relief of pressure on nerve root. Most patients get off the table pain free and are back to work in 5 to 7 days. Material and method: to date, 130 patients (155 cases) suffering for relevant symptoms therapy-resistant 6 months on average before consulting our department, have been treated. Eightyfour (72%) males and 46 (28%) females had a percutaneous laser disc nucleoplasty. The average age of patients operated was 48 years (22 - 69). The level of disc removal was L3/L4 in 12 cases, L4/L5 in 87 cases and L5/S1 in 56 cases. Two different levels were treated at the same time in 25 patients. Results: the success rate at a minimum follow-up of 6 months was 88% with a complication rate of 0.5%.

  18. E-Content Development for Languages: Success Factors and Pitfalls

    ERIC Educational Resources Information Center

    De Paepe, Liesbeth

    2014-01-01

    This paper discusses the success factors and pitfalls in development of e-content for languages. The factors discussed draw on several years of experience in developing and implementing 95% distance courses for Dutch as a second language in the adult education sector in Flanders and on PhD research at VUB. The CEFR [Common European Framework of…

  19. Pitfalls and Limitations of Radionuclide Imaging in Endocrinology.

    PubMed

    Agrawal, Kanhaiyalal; Esmail, Abdulredha A H; Gnanasegaran, Gopinath; Navalkissoor, Shaunak; Mittal, Bhagwant Rai; Fogelman, Ignac

    2015-09-01

    Several different techniques, radiopharmaceuticals, and imaging modalities are commonly used in nuclear medicine for studies of endocrine organs. Nuclear medicine is used in the management of benign and malignant thyroid, parathyroid, and neuroendocrine disorders. Thus, it is essential to acknowledge pitfalls and the limitations of nuclear medicine imaging for accurate diagnosis and patient management.

  20. The Pitfalls of Testing in the Quest of Excellence.

    ERIC Educational Resources Information Center

    Goodwin, Coleen R.

    This document presents five scenarios, each referring to a means of assessing learning. These examples are then used to discuss pitfalls faced when tests are used to assess learning, and the conclusion is reached that testing should play a supportive role only, not a major role in the quest for excellence. Effective schools research shows that…

  1. The Pitfalls and Triumphs of Launching a Charter School.

    ERIC Educational Resources Information Center

    Page, Linda; Levine, Mark

    1996-01-01

    A principal of a charter school in Colorado Springs, Colorado, recounts the triumphs and pitfalls of the school's first year. The school charter lacked a clear-cut avenue for making changes. Intending to create a parent-run school, the founding board (themselves parents) made drastic curricular changes without consulting other parents. Passionate…

  2. Proposal Pitfalls Plaguing Researchers: Can Technical Communicators Make a Difference?

    ERIC Educational Resources Information Center

    Lemanski, Steve

    2014-01-01

    The facts bear out that the odds are against most scientific researchers and scholars--especially those just starting out--in their attempts to win funding for their research projects through their grant proposals. In this article, the author takes a close look at some of the proposal-related problems and pitfalls that have historically challenged…

  3. Pseudocarcinomatous hyperplasia involving the ear from gout: a diagnostic pitfall.

    PubMed

    Morrissey, Kelly A; Garcia-Albea, Victoria; Goldberg, Lynne J

    2014-01-01

    The ear is a characteristic location for deposition of uric acid in patients with gout. Pseudocarcinomatous hyperplasia has not been described in this location. We report three patients with tophaceous gout on the ear whose biopsies exhibited epidermal hyperplasia mimicking squamous cell carcinoma, in order to call attention to this potential diagnostic pitfall.

  4. The ILR Oral Interview: Origins, Applications, Pitfalls, and Implications.

    ERIC Educational Resources Information Center

    Leow, Pardee, Jr.

    1983-01-01

    Describes the original FSI oral interview and the ACTFL/ETS modifications. Discusses: (1) the characteristics of the test, (2) some possible pitfalls in application and their remedies, and (3) some possible long range effects of the oral interview on second language teaching and testing. Provisional generic descriptions for speaking and…

  5. Cases on Global E-Learning Practices: Successes and Pitfalls

    ERIC Educational Resources Information Center

    Sharma, Ramesh C., Ed.; Mishra, Sanjaya, Ed.

    2007-01-01

    "Cases on Global E-Learning Practices: Successes and Pitfalls" looks into global practices of e-learning, examining the successes and failures of e-learning professionals. It provides a judicious mix of practical experiences and research in the form of case studies. Written by experts from all over the globe, this book shows how to…

  6. Evolution of protoplanetary discs with magnetically driven disc winds

    NASA Astrophysics Data System (ADS)

    Suzuki, Takeru K.; Ogihara, Masahiro; Morbidelli, Alessandro; Crida, Aurélien; Guillot, Tristan

    2016-12-01

    Aims: We investigate the evolution of protoplanetary discs (PPDs) with magnetically driven disc winds and viscous heating. Methods: We considered an initially massive disc with 0.1 M⊙ to track the evolution from the early stage of PPDs. We solved the time evolution of surface density and temperature by taking into account viscous heating and the loss of mass and angular momentum by the disc winds within the framework of a standard α model for accretion discs. Our model parameters, turbulent viscosity, disc wind mass-loss, and disc wind torque, which were adopted from local magnetohydrodynamical simulations and constrained by the global energetics of the gravitational accretion, largely depends on the physical condition of PPDs, particularly on the evolution of the vertical magnetic flux in weakly ionized PPDs. Results: Although there are still uncertainties concerning the evolution of the vertical magnetic flux that remains, the surface densities show a large variety, depending on the combination of these three parameters, some of which are very different from the surface density expected from the standard accretion. When a PPD is in a wind-driven accretion state with the preserved vertical magnetic field, the radial dependence of the surface density can be positive in the inner region <1-10 au. The mass accretion rates are consistent with observations, even in the very low level of magnetohydrodynamical turbulence. Such a positive radial slope of the surface density strongly affects planet formation because it inhibits the inward drift or even causes the outward drift of pebble- to boulder-sized solid bodies, and it also slows down or even reversed the inward type-I migration of protoplanets. Conclusions: The variety of our calculated PPDs should yield a wide variety of exoplanet systems.

  7. Polarimetric Models of Circumstellar Discs Including Aggregate Dust Grains

    NASA Astrophysics Data System (ADS)

    Mohan, Mahesh

    The work conducted in this thesis examines the nature of circumstellar discs by investigating irradiance and polarization of scattered light. Two circumstellar discs are investigated. Firstly, H-band high contrast imaging data on the transitional disc of the Herbig Ae/Be star HD169142 are presented. The images were obtained through the polarimetric differential imaging (PDI) technique on the Very Large Telescope (VLT) using the adaptive optics system NACO. Our observations use longer exposure times, allowing us to examine the edges of the disc. Analysis of the observations shows distinct signs of polarization due to circumstellar material, but due to excessive saturation and adaptive optics errors further information on the disc could not be inferred. The HD169142 disc is then modelled using the 3D radiative transfer code Hyperion. Initial models were constructed using a two disc structure, however recent PDI has shown the existence of an annular gap. In addition to this the annular gap is found not to be devoid of dust. This then led to the construction of a four-component disc structure. Estimates of the mass of dust in the gap (2.10E-6 Msun) are made as well as for the planet (1.53E-5 Msun (0.016 Mjupiter)) suspected to be responsible for causing the gap. The predicted polarization was also estimated for the disc, peaking at ~14 percent. The use of realistic dust grains (ballistic aggregate particles) in Monte Carlo code is also examined. The fortran code DDSCAT is used to calculate the scattering properties for aggregates which are used to replace the spherical grain models used by the radiative transfer code Hyperion. Currently, Hyperion uses four independent elements to define the scattering matrix, therefore the use of rotational averaging and a 50/50 percent population of grains and their enantiomers were explored to reduce the number of contributing scattering elements from DDSCAT. A python script was created to extract the scattering data from the DDSCAT

  8. [Total Elbow Replacement - Implantation of the Latitude Prosthesis (Tornier)].

    PubMed

    Hackl, M; Wegmann, K; Leschinger, T; Ries, C; Burkhart, K J; Müller, L

    2015-10-01

    Due to technical progress, the indication for total elbow arthroplasty could be expanded in recent years. As a result, the demand regarding functionality and mobility of the replaced joint has risen as well. Elbow arthroplasty has to be considered as technically demanding. Only with detailed knowledge of this surgical procedure and its possible intraoperative pitfalls can one provide the best possible results. In this instructional video we explain the implantation of the Latitude elbow prosthesis (Tornier) putting emphasis on the correct approach as well as implantation of the prosthesis and subsequent wound closure.

  9. Role of biomechanics on intervertebral disc degeneration and regenerative therapies: What needs repairing in the disc and what are promising biomaterials for its repair?

    PubMed Central

    Iatridis, James C.; Nicoll, Steven B.; Michalek, Arthur J.; Walter, Benjamin A.; Gupta, Michelle S.

    2013-01-01

    Background Context Degeneration and injuries of the intervertebral disc result in large alterations in biomechanical behaviors. Repair strategies using biomaterials can be optimized based on biomechanical and biological requirements. Purpose To review current literature on 1) effects of degeneration, simulated degeneration, and injury on biomechanics of the intervertebral disc with special attention paid to needle puncture injuries which are a pathway for diagnostics and regenerative therapies; and 2) promising biomaterials for disc repair with a focus on how those biomaterials may promote biomechanical repair. Study Design/Setting A narrative review to evaluate the role of biomechanics on disc degeneration and regenerative therapies with a focus on what biomechanical properties need to be repaired and how to evaluate and accomplish such repairs using biomaterials. Model systems for screening of such repair strategies are also briefly described. Methods Papers were selected from two main Pubmed searches using keywords: intervertebral AND biomechanics (1823 articles) and intervertebral AND biomaterials (361 articles). Additional keywords (injury, needle puncture, nucleus pressurization, biomaterials, hydrogel, sealant, tissue engineering) were used to narrow articles to the topics most relevant to this review. Results Degeneration and acute disc injuries have the capacity to influence nucleus pulposus pressurization and annulus fibrosus integrity, which are necessary for effective disc function, and therefore, require repair. Needle injection injuries are of particular clinical relevance with potential to influence disc biomechanics, cellularity, and metabolism, yet these effects are localized or small, and more research is required to evaluate and reduce potential clinical morbidity using such techniques. NP replacement strategies, such as hydrogels, are required to restore NP pressurization or lost volume. AF repair strategies, including crosslinked hydrogels

  10. Biological treatment strategies for disc degeneration: potentials and shortcomings

    PubMed Central

    Nerlich, Andreas G.; Boos, Norbert

    2006-01-01

    Recent advances in molecular biology, cell biology and material sciences have opened a new emerging field of techniques for the treatment of musculoskeletal disorders. These new treatment modalities aim for biological repair of the affected tissues by introducing cell-based tissue replacements, genetic modifications of resident cells or a combination thereof. So far, these techniques have been successfully applied to various tissues such as bone and cartilage. However, application of these treatment modalities to cure intervertebral disc degeneration is in its very early stages and mostly limited to experimental studies in vitro or in animal studies. We will discuss the potential and possible shortcomings of current approaches to biologically cure disc degeneration by gene therapy or tissue engineering. Despite the increasing number of studies examining the therapeutic potential of biological treatment strategies, a practicable solution to routinely cure disc degeneration might not be available in the near future. However, knowledge gained from these attempts might be applied in a foreseeable future to cure the low back pain that often accompanies disc degeneration and therefore be beneficial for the patient. PMID:16983559

  11. Wear analysis of disc cutters of full face rock tunnel boring machine

    NASA Astrophysics Data System (ADS)

    Zhang, Zhaohuang; Meng, Liang; Sun, Fei

    2014-11-01

    Wear is a major factor of disc cutters' failure. No current theory offers a standard for the prediction of disc cutter wear yet. In the field the wear prediction method commonly used is based on the excavation length of tunnel boring machine(TBM) to predict the disc cutter wear and its wear law, considering the location number of each disc cutter on the cutterhead(radius for installation); in theory, there is a prediction method of using arc wear coefficient. However, the preceding two methods have their own errors, with their accuracy being 40% or so and largely relying on the technicians' experience. Therefore, radial wear coefficient, axial wear coefficient and trajectory wear coefficient are defined on the basis of the operating characteristics of TBM. With reference to the installation and characteristics of disc cutters, those coefficients are modified according to penetration, which gives rise to the presentation of comprehensive axial wear coefficient, comprehensive radial wear coefficient and comprehensive trajectory wear coefficient. Calculation and determination of wear coefficients are made with consideration of data from a segment of TBM project(excavation length 173 m). The resulting wear coefficient values, after modification, are adopted to predict the disc cutter wear in the follow-up segment of the TBM project(excavation length of 5621 m). The prediction results show that the disc cutter wear predicted with comprehensive radial wear coefficient and comprehensive trajectory wear coefficient are not only accurate(accuracy 16.12%) but also highly congruous, whereas there is a larger deviation in the prediction with comprehensive axial wear coefficient(accuracy 41%, which is in agreement with the prediction of disc cutters' life in the field). This paper puts forth a new method concerning prediction of life span and wear of TBM disc cutters as well as timing for replacing disc cutters.

  12. Gravitoturbulence in magnetized protostellar discs

    NASA Astrophysics Data System (ADS)

    Riols, A.; Latter, H.

    2016-08-01

    Gravitational instability (GI) features in several aspects of protostellar disc evolution, most notably in angular momentum transport, fragmentation, and the outbursts exemplified by FU Ori and EX Lupi systems. The outer regions of protostellar discs may also be coupled to magnetic fields, which could then modify the development of GI. To understand the basic elements of their interaction, we perform local 2D ideal and resistive magnetohydrodynamics simulations with an imposed toroidal field. In the regime of moderate plasma beta, we find that the system supports a hot gravitoturbulent state, characterized by considerable magnetic energy and stress and a surprisingly large Toomre parameter Q ≳ 10. This result has potential implications for disc structure, vertical thickness, ionization, etc. Our simulations also reveal the existence of long-lived and dense `magnetic islands' or plasmoids. Lastly, we find that the presence of a magnetic field has little impact on the fragmentation criterion of the disc. Though our focus is on protostellar discs, some of our results may be relevant for the outer radii of AGN.

  13. [Imaging monitors--requirements and pitfalls].

    PubMed

    Simmler, R

    2013-11-01

    When applying the standard DIN V 6868-57 rule "acceptance testing for image display devices" it always comes to misunderstandings in the practical implementation. In a brief summary the most important requirements are presented. With the pending replacement of DIN V 6868-57 by DIN 6868-157 "acceptance and constancy tests of image display systems in their environment" there will be fundamental changes. Future requirements are presented as examples. Besides the introduction of a classroom concept and new test images, the focus of the standard is aligned with the image display system. This change places new demands on the management concept of picture archiving and communication system (PACS) workstations. For testing the unit, consisting of a computer system, video card, operating system and image display equipment only one organizational unit should be responsible.

  14. Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients

    PubMed Central

    Weinberg, Ian R.; Sliwa, Karen; Sweet, Barry MBE; de Villiers, Malan

    2007-01-01

    Background The Kineflex lumbar disc is a mechanical, unconstrained, re-centering disc prosthesis developed in South Africa. The first implantation took place in October 2002. We present a single-center, prospective, longitudinal study of the first 100 patients treated with the Kineflex lumbar disc. Our objective was to evaluate the insertion technique, clinical outcomes, and patient satisfaction at 2 years postimplantation in 100 consecutive patients with 132 (68 single- and 32 2-level) Kineflex lumbar disc replacements. Methods We determined the exact central placement of all disc implants in the coronal and midsagittal planes. We measured clinical outcome with the Oswestry disability index (ODI), our own questionnaire, and the time needed to return to work. All patients received radiological and clinical follow-up assessments for 2 years after the index procedure. Results Forty-three patients were female. The mean age of the patients at operation was 44.9 years (range, 23–63 years). Postoperative hospitalization averaged 2.8 days (range, 2 to 8 days). All patients who were employed before surgery returned to work 31 ± 16.8 days after the operation. Fifty-six percent of operated disc levels had intervertebral disc heights of less than 5 mm. A 2-year clinical outcome was available for 98 of the 100 patients (58 excellent, 30 good, 7 fair, 3 poor). The ODI score improved from 47.8 ± 16.0 preoperatively to 14.2 ± 14.0 (P < .01) at 2 years. At 2 years, 95% of disc implants were radiologically in the ideal position. The insertion technique, with a released prosthetic mechanism for final placement, allowed ideal placement in the sagittal plane in 98% of discs. The radiographic placement accuracy achieved was equal in patients with preoperative intervertebral disc height below and above 5 mm. Conclusions Good short-term clinical results were achieved with the Kineflex disc in a heterogeneous patient group with a high number of patients with advanced disc

  15. Atomic gas in debris discs

    NASA Astrophysics Data System (ADS)

    Hales, Antonio S.; Barlow, M. J.; Crawford, I. A.; Casassus, S.

    2017-04-01

    We have conducted a search for optical circumstellar absorption lines in the spectra of 16 debris disc host stars. None of the stars in our sample showed signs of emission line activity in either Hα, Ca II or Na I, confirming their more evolved nature. Four stars were found to exhibit narrow absorption features near the cores of the photospheric Ca II and Na I D lines (when Na I D data were available). We analyse the characteristics of these spectral features to determine whether they are of circumstellar or interstellar origins. The strongest evidence for circumstellar gas is seen in the spectrum of HD 110058, which is known to host a debris disc observed close to edge-on. This is consistent with a recent ALMA detection of molecular gas in this debris disc, which shows many similarities to the β Pictoris system.

  16. Eddy current braking experiment using brake disc from aluminium series of A16061 and A17075

    NASA Astrophysics Data System (ADS)

    Baharom, M. Z.; Nuawi, M. Z.; Priyandoko, G.; Harris, S. M.

    2012-09-01

    The electromagnetic braking using eddy current was studied, focused on two series of aluminium as the brake disc which are A16061 and A17075. This paper presents the comparison for both series in a few varied parameters related to eddy current braking such as air-gap, number of turns and brake disc thickness. Optical tachometer has been used along with PULSE analyzer to capture the speed (rpm) and time (s). The findings shows that the smaller the air-gap, the larger of electromagnet turns and the thicker disc thickness is, will generate higher braking torque to stop the rotational motion of disc brake and give great performance for eddy current braking. Thos parameters that been evaluated also addressed a potential on expanding this knowledge to develop an electromagnetic braking system to replace the conventional braking system.

  17. Coevolution of binaries and circumbinary gaseous discs

    NASA Astrophysics Data System (ADS)

    Fleming, David P.; Quinn, Thomas R.

    2017-01-01

    The recent discoveries of circumbinary planets by Kepler raise questions for contemporary planet formation models. Understanding how these planets form requires characterizing their formation environment, the circumbinary protoplanetary disc and how the disc and binary interact and change as a result. The central binary excites resonances in the surrounding protoplanetary disc which drive evolution in both the binary orbital elements and in the disc. To probe how these interactions impact binary eccentricity and disc structure evolution, N-body smooth particle hydrodynamics simulations of gaseous protoplanetary discs surrounding binaries based on Kepler 38 were run for 104 binary periods for several initial binary eccentricities. We find that nearly circular binaries weakly couple to the disc via a parametric instability and excite disc eccentricity growth. Eccentric binaries strongly couple to the disc causing eccentricity growth for both the disc and binary. Discs around sufficiently eccentric binaries which strongly couple to the disc develop an m = 1 spiral wave launched from the 1:3 eccentric outer Lindblad resonance which corresponds to an alignment of gas particle longitude of periastrons. All systems display binary semimajor axis decay due to dissipation from the viscous disc.

  18. Determination of the intervertebral disc space from CT images of the lumbar spine

    NASA Astrophysics Data System (ADS)

    Korez, Robert; Å tern, Darko; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-03-01

    Degenerative changes of the intervertebral disc are among the most common causes of low back pain, where for individuals with significant symptoms surgery may be needed. One of the interventions is the total disc replacement surgery, where the degenerated disc is replaced by an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study we propose a method for the determination of the intervertebral disc space from three-dimensional (3D) computed tomography (CT) images of the lumbar spine. The first step of the proposed method is the construction of a model of vertebral bodies in the lumbar spine. For this purpose, a chain of five elliptical cylinders is initialized in the 3D image and then deformed to resemble vertebral bodies by introducing 25 shape parameters. The parameters are obtained by aligning the chain to the vertebral bodies in the CT image according to image intensity and appearance information. The determination of the intervertebral disc space is finally achieved by finding the planes that fit the endplates of the obtained parametric 3D models, and placing points in the space between the planes of adjacent vertebrae that enable surface reconstruction of the intervertebral disc space. The morphometric analysis of images from 20 subjects yielded 11:3 +/- 2:6, 12:1 +/- 2:4, 12:8 +/- 2:0 and 12:9 +/- 2:7 cm3 in terms of L1-L2, L2-L3, L3-L4 and L4-L5 intervertebral disc space volume, respectively.

  19. [Spinal instrumentation, source of progress, but also revealing pitfalls].

    PubMed

    Dubousset, Jean

    2003-01-01

    addition the noticed improvements on the biological field for fusion with bone activators like BMP, Hydroxyapatite, or bone substitutes like bio-active ceramics will probably help for fusion and decrease necessity of bone grafting. It is the same about disc regeneration which is on the way. Finally it is evident that the first steps already done for spinal surgery avoiding fusion will extend.--For children and growing spine, the challenge is major, but with memory metal instruments, laser precise destruction of abnormal growing structures as well as posterior flexible instrumentation avoiding stripping of the periosteum and leaving integrity of the disc and facet joints function, improvements are also on the way.--For adult and degenerative spinal deformities and pain, the development of spinal arthroplasty already done for the disc replacement will improve as well as for the posterior joints units where artificial ligaments experience will be replaced by real artificial joints still on experiment. In conclusion, some general biological medical questions are still waiting for answers:--Neurology and erect posture--Growth and degeneration--Malignancy (comprehension and control)--Pain and suffering. And of course what is the fact of the genetics for all of these problems: plenty of work for the future.

  20. Herpetological Monitoring Using a Pitfall Trapping Design in Southern California

    USGS Publications Warehouse

    Fisher, Robert; Stokes, Drew; Rochester, Carlton; Brehme, Cheryl; Hathaway, Stacie; Case, Ted

    2008-01-01

    The steps necessary to conduct a pitfall trapping survey for small terrestrial vertebrates are presented. Descriptions of the materials needed and the methods to build trapping equipment from raw materials are discussed. Recommended data collection techniques are given along with suggested data fields. Animal specimen processing procedures, including toe- and scale-clipping, are described for lizards, snakes, frogs, and salamanders. Methods are presented for conducting vegetation surveys that can be used to classify the environment associated with each pitfall trap array. Techniques for data storage and presentation are given based on commonly use computer applications. As with any study, much consideration should be given to the study design and methods before beginning any data collection effort.

  1. Taming Healthcare Costs: Promise and Pitfalls for Women's Health

    PubMed Central

    Glynn, Amy; MacKenzie, Rose

    2016-01-01

    Abstract When it comes to healthcare, women are often the primary decision makers for their families. Therefore, focusing on women and their health needs can have a profound effect on health reform efforts to control costs and improve quality for all segments of the population. The promise and pitfalls of cost containment reform in Massachusetts can serve as an informative case study for policymakers at the local, state, and federal levels as they attempt to reduce costs while maintaining quality of care. Massachusetts cost containment law, Chapter 224, seeks to control the healthcare cost growth through innovative approaches to increase efficiency and transparency including the adoption of new delivery system models, investments in wellness and prevention programs, and implementation of standard quality and evaluation measures. In this paper, we outline four approaches to delivering on the promise of cost containment reform to maximize women's access to comprehensive, quality healthcare while avoiding the pitfalls of cost containment's adverse impact on women's health. PMID:26488183

  2. Pitfalls to avoid when using phage display for snake toxins.

    PubMed

    Laustsen, Andreas Hougaard; Lauridsen, Line Præst; Lomonte, Bruno; Andersen, Mikael Rørdam; Lohse, Brian

    2017-02-01

    Antivenoms against bites and stings from snakes, spiders, and scorpions are associated with immunological side effects and high cost of production, since these therapies are still derived from the serum of hyper-immunized production animals. Biotechnological innovations within envenoming therapies are thus warranted, and phage display technology may be a promising avenue for bringing antivenoms into the modern era of biologics. Although phage display technology represents a robust and high-throughput approach for the discovery of antibody-based antitoxins, several pitfalls may present themselves when animal toxins are used as targets for phage display selection. Here, we report selected critical challenges from our own phage display experiments associated with biotinylation of antigens, clone picking, and the presence of amber codons within antibody fragment structures in some phage display libraries. These challenges may be detrimental to the outcome of phage display experiments, and we aim to help other researchers avoiding these pitfalls by presenting their solutions.

  3. Partial knee replacement - slideshow

    MedlinePlus

    ... page: //medlineplus.gov/ency/presentations/100225.htm Partial knee replacement - series—Normal anatomy To use the sharing ... A.M. Editorial team. Related MedlinePlus Health Topics Knee Replacement A.D.A.M., Inc. is accredited ...

  4. Radiative transfer modelling of parsec-scale dusty warped discs

    NASA Astrophysics Data System (ADS)

    Jud, H.; Schartmann, M.; Mould, J.; Burtscher, L.; Tristram, K. R. W.

    2017-02-01

    Warped discs have been found on (sub-)parsec scale in some nearby Seyfert nuclei, identified by their maser emission. Using dust radiative transfer simulations, we explore their observational signatures in the infrared in order to find out whether they can partly replace the molecular torus. Strong variations of the brightness distributions are found, depending on the orientation of the warp with respect to the line of sight. Whereas images at short wavelengths typically show a disc-like and a point source component, the warp itself only becomes visible at far-infrared wavelengths. A similar variety is visible in the shapes of the spectral energy distributions. Especially for close to edge-on views, the models show silicate feature strengths ranging from deep absorption to strong emission for variations of the lines of sight towards the warp. To test the applicability of our model, we use the case of the Circinus galaxy, where infrared interferometry has revealed a highly elongated emission component matching a warped maser disc in orientation and size. Our model is for the first time able to present a physical explanation for the observed dust morphology as coming from the active galactic nuclei heated dust. As opposed to available torus models, a warped disc morphology produces a variety of silicate feature shapes for grazing lines of sight, close to an edge-on view. This could be an attractive alternative to a claimed change of the dust composition for the case of the nearby Seyfert 2 galaxy NGC 1068, which harbours a warped maser disc as well.

  5. Simulations of magnetic fields in isolated disc galaxies

    NASA Astrophysics Data System (ADS)

    Pakmor, Rüdiger; Springel, Volker

    2013-06-01

    Magnetic fields are known to be dynamically important in the interstellar medium of our own Galaxy, and they are ubiquitously observed in diffuse gas in the haloes of galaxies and galaxy clusters. Yet, magnetic fields have typically been neglected in studies of the formation of galaxies, leaving their global influence on galaxy formation largely unclear. Here we extend our magnetohydrodynamics (MHD) implementation in the moving-mesh code AREPO to cosmological problems which include radiative cooling and the formation of stars. In particular, we replace our previously employed divergence cleaning approach with a Powell eight-wave scheme, which turns out to be significantly more stable, even in very dynamic environments. We verify the improved accuracy through simulations of the magneto-rotational instability in accretion discs, which reproduce the correct linear growth rate of the instability. Using this new MHD code, we simulate the formation of isolated disc galaxies similar to the Milky Way using idealized initial conditions with and without magnetic fields. We find that the magnetic field strength is quickly amplified in the initial central starburst and the differential rotation of the forming disc, eventually reaching a saturation value. At this point, the magnetic field pressure in the interstellar medium becomes comparable to the thermal pressure, and a further efficient growth of the magnetic field strength is prevented. The additional pressure component leads to a lower star formation rate at late times compared to simulations without magnetic fields, and induces changes in the spiral arm structures of the gas disc. In addition, we observe highly magnetized fountain-like outflows from the disc. These results are robust with numerical resolution and are largely independent of the initial magnetic seed field strength assumed in the initial conditions, as the amplification process is rapid and self-regulated. Our findings suggest an important influence of

  6. Off-pump coronary artery bypass: techniques, pitfalls, and results.

    PubMed

    Hoff, Steven J

    2009-01-01

    In an attempt to advance the surgical treatment of coronary artery disease, surgeons sought a way to offer the proven benefits of coronary revascularization and avoid the side effects of cardiopulmonary bypass by performing revascularization in the beating heart (off-pump coronary artery bypass). This review will describe the development and refinement of the technique, pitfalls to its widespread adoption, and an up-to-date assessment of current results.

  7. Problems and pitfalls in a clinical research data management system.

    PubMed

    Brower, R W; ten Katen, H J; Meester, G T

    1984-01-01

    The problems and pitfalls encountered in the computerized data bank for the Netherlands Coronary Surgery (NCS) study are reviewed. This study involved 848 patients seen before coronary artery surgery and at 1 and 3 yr after surgery. Nineteen data forms were used resulting in maximally 1142 variables per patient. The importance of quality control is emphasized as well as the efficient transfer of information from data bank to statistical processing.

  8. Using demographic data to better interpret pitfall trap catches

    PubMed Central

    Matalin, Andrey V.; Makarov, Kirill V.

    2011-01-01

    Abstract The results of pitfall trapping are often interpreted as abundance in a particular habitat. At the same time, there are numerous cases of almost unrealistically high catches of ground beetles in seemingly unsuitable sites. The correlation of catches by pitfall trapping with the true distribution and abundance of Carabidae needs corroboration. During a full year survey in 2006/07 in the Lake Elton region (Volgograd Area, Russia), 175 species of ground beetles were trapped. Considering the differences in demographic structure of the local populations, and not their abundances, three groups of species were recognized: residents, migrants and sporadic. In residents, the demographic structure of local populations is complete, and their habitats can be considered “residential”. In migrants and sporadic species, the demographic structure of the local populations is incomplete, and their habitats can be considered “transit”. Residents interact both with their prey and with each other in a particular habitat. Sporadic species are hardly important to a carabid community because of their low abundances. The contribution of migrants to the structure of carabid communities is not apparent and requires additional research. Migrants and sporadic species represent a “labile” component in ground beetles communities, as opposed to a “stable” component, represented by residents. The variability of the labile component substantially limits our interpretation of species diversity in carabid communities. Thus, the criteria for determining the most abundant, or dominant species inevitably vary because the abundance of migrants in some cases can be one order of magnitude higher than that of residents. The results of pitfall trapping adequately reflect the state of carabid communities only in zonal habitats, while azonal and disturbed habitats are merely transit ones for many species of ground beetles. A study of the demographic structure of local populations and

  9. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... permanent dark ink or its equivalent; and (v) Presented in a form having sufficient clarity and contrast... submitted may contain alterations that do not introduce matter that would have been new matter in the prior... new matter. The compact disc and copy must be labeled “COPY 1 REPLACEMENT MM/DD/YYYY” (with the...

  10. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... permanent dark ink or its equivalent; and (v) Presented in a form having sufficient clarity and contrast... submitted may contain alterations that do not introduce matter that would have been new matter in the prior... new matter. The compact disc and copy must be labeled “COPY 1 REPLACEMENT MM/DD/YYYY” (with the...

  11. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... permanent dark ink or its equivalent; and (v) Presented in a form having sufficient clarity and contrast... submitted may contain alterations that do not introduce matter that would have been new matter in the prior... new matter. The compact disc and copy must be labeled “COPY 1 REPLACEMENT MM/DD/YYYY” (with the...

  12. Photoevaporating transitional discs and molecular cloud cores

    NASA Astrophysics Data System (ADS)

    Li, Min; Sui, Ning

    2017-04-01

    We investigate the evolution of photoevaporating protoplanetary discs including mass influx from molecular cloud cores. We examine the influence of cloud core properties on the formation and evolution of transitional discs. We use one-dimensional thin disc assumption and calculate the evolution of the protoplanetary disc. The effects of X-ray photoevaporation are also included. Our calculations suggest that most discs should experience the transitional disc phase within 10 Myr. The formation time of a gap and its initial location are functions of the properties of the cloud cores. In some circumstances, discs can open two gaps by photoevaporation alone. The two gaps form when the gas in the disc can expand to large radius and if the mass at large radius is sufficiently small. The surface density profile of the disc determines whether the two gaps can form. Since the structure of a disc is determined by the properties of a molecular cloud core, the core properties determine the formation of two gaps in the disc. We further find that even when the photoevaporation rate is reduced to 10 per cent of the standard value, two gaps can still form in the disc. The only difference is that the formation time is delayed.

  13. Electromagnetic Levitation of a Disc

    ERIC Educational Resources Information Center

    Valle, R.; Neves, F.; de Andrade, R., Jr.; Stephan, R. M.

    2012-01-01

    This paper presents a teaching experiment that explores the levitation of a disc of ferromagnetic material in the presence of the magnetic field produced by a single electromagnet. In comparison to the classical experiment of the levitation of a sphere, the main advantage of the proposed laboratory bench is that the uniform magnetic field…

  14. A Structurally and Functionally Biomimetic Biphasic Scaffold for Intervertebral Disc Tissue Engineering

    PubMed Central

    Choy, Andrew Tsz Hang; Chan, Barbara Pui

    2015-01-01

    Tissue engineering offers high hopes for the treatment of intervertebral disc (IVD) degeneration. Whereas scaffolds of the disc nucleus and annulus have been extensively studied, a truly biomimetic and mechanically functional biphasic scaffold using naturally occurring extracellular matrix is yet to be developed. Here, a biphasic scaffold was fabricated with collagen and glycosaminoglycans (GAGs), two of the most abundant extracellular matrix components in the IVD. Following fabrication, the scaffold was characterized and benchmarked against native disc. The biphasic scaffold was composed of a collagen-GAG co-precipitate making up the nucleus pulposus-like core, and this was encapsulated in multiple lamellae of photochemically crosslinked collagen membranes comprising the annulus fibrosus-like lamellae. On mechanical testing, the height of our engineered disc recovered by ~82-89% in an annulus-independent manner, when compared with the 99% recovery exhibited by native disc. The annulus-independent nature of disc height recovery suggests that the fluid replacement function of the engineered nucleus pulposus core might mimic this hitherto unique feature of native disc. Biphasic scaffolds comprised of 10 annulus fibrosus-like lamellae had the best overall mechanical performance among the various designs owing to their similarity to native disc in most aspects, including elastic compliance during creep and recovery, and viscous compliance during recovery. However, the dynamic mechanical performance (including dynamic stiffness and damping factor) of all the biphasic scaffolds was similar to that of the native discs. This study contributes to the rationalized design and development of a biomimetic and mechanically viable biphasic scaffold for IVD tissue engineering. PMID:26115332

  15. Peripheral Disc Margin Shape and Internal Disc Derangement: Imaging Correlation in Significantly Painful Discs Identified at Provocation Lumbar Discography

    PubMed Central

    Bartynski, W.S.; Rothfus, W.E.

    2012-01-01

    Summary Annular margin shape is used to characterize lumbar disc abnormality on CT/MR imaging studies. Abnormal discs also have internal derangement including annular degeneration and radial defects. The purpose of this study was to evaluate potential correlation between disc-margin shape and annular internal derangement on post-discogram CT in significantly painful discs encountered at provocation lumbar discography (PLD). Significantly painful discs were encountered at 126 levels in 86 patients (47 male, 39 female) studied by PLD where no prior surgery had been performed and response to intradiscal lidocaine after provocation resulted in either substantial/total relief or no improvement after lidocaine administration. Post-discogram CT and discogram imaging was evaluated for disc-margin characteristics (bulge/protrusion), features of disc internal derangement (radial annular defect [RD: radial tear/fissure/annular gap], annular degeneration) and presence/absence of discographic contrast leakage. In discs with focal protrusion, 50 of 63 (79%) demonstrated Grade 3 RD with 13 (21%) demonstrating severe degenerative change only. In discs with generalized-bulge-only, 48 of 63 (76%) demonstrated degenerative change only (primarily Dallas Grade 3) with 15 of 63 (24%) demonstrating a RD (Dallas Grade 3). Differences were highly statistically significant (p<0.001). Pain elimination with intra-discal lidocaine correlated with discographic contrast leakage (p<0.001). Disc-margin shape correlates with features of internal derangement in significantly painful discs encountered at PLD. Discs with focal protrusion typically demonstrate RD while generalized bulging discs typically demonstrated degenerative changes only (p<0.001). Disc-margin shape may provide an important imaging clue to the cause of chronic discogenic low back pain. PMID:22681741

  16. Nubac Disc Arthroplasty: Preclinical Studies and Preliminary Safety and Efficacy Evaluations

    PubMed Central

    Songer, Matthew; Pimenta, Luis; Werner, Dieter; Reyes-Sanchez, Alejandro; Balsano, Massimo; Agrillo, Umberto; Coric, Domagoj; Davenport, Kenneth; Yuan, Hansen

    2007-01-01

    Background Disc arthroplasty is gaining popularity for treatment of low-back pain caused by degenerative disc disease (DDD). It can involve total disc replacement or partial disc or nucleus replacement (or augmentation). Compared with total disc replacement, nucleus replacement is less invasive, has less surgical risk, has faster postoperative recovery, and doesn't “burn bridges” should further surgery be required. However, nucleus replacement has a high risk of implant expulsion because the device is not fixed to the vertebrae. Nubac is the first polyetheretherketone (PEEK)-on-PEEK articulated disc arthroplasty device designed to optimally restore the lumbar anatomy and biomechanics. Methods ISO 10993 standards were used to evaluate the biocompatibility of the PEEK material. Chemical and thermal–mechanical tests and in vivo study assessed PEEK's biostability after exposure to high g irradiation and harsh oxidative conditions. Biomechanical tests to evaluate kinematic properties and anatomical restoration of the implanted lumbar motion segments and implant expulsion risk assessments were performed with a human cadaveric model. Because of the novelty of PEEK-on-PEEK as a self-mating articulating material, extensive wear tests were conducted with unidirectional and coupled motions. Static and fatigue strength also were tested. Animal study with a baboon model was conducted with gross, radiographic, biomechanical, and histological evaluations at 6 and 12 months postoperatively. Preliminary clinical data were collected through a prospective multicenter cohort study. Results PEEK demonstrated exceptional biocompatibility and biodurability. Nubac restored disc height and motion segment range of motion. The unique articulating design of the Nubac demonstrated low risk of implant expulsion in a human cadaveric model. Wear tests showed that the Nubac has minimal wear and compares favorably to other disc arthroplasty materials. The Nubac also had excellent static and

  17. [Optic disc granuloma secondary to sarcoidosis].

    PubMed

    Qu-Knafo, L; Auregan-Giocanti, A

    2017-02-01

    We report a case of optic disc granuloma due to sarcoidosis. A 64-year-old, caucasian female with a history of pulmonary sarcoidosis presented with a vision loss on her left eye. The ophthalmologic examination revealed a discrete optic disc infiltrate compatible with the diagnosis of optic disc granuloma. Fluorescein angiography showed diffusion and impregnation of the granuloma without vascularitis. The optical coherence tomography demonstrated a homogenous and isoreflective lesion at the optic disc. The patient recovered her visual acuity after systemic corticosteroid treatment. Isolated optic disc granuloma is a rare condition of ocular sarcoidosis.

  18. Artificial Discs for Lumbar and Cervical Degenerative Disc Disease –Update

    PubMed Central

    2006-01-01

    Executive Summary Objective To assess the safety and efficacy of artificial disc replacement (ADR) technology for degenerative disc disease (DDD). Clinical Need Degenerative disc disease is the term used to describe the deterioration of 1 or more intervertebral discs of the spine. The prevalence of DDD is roughly described in proportion to age such that 40% of people aged 40 years have DDD, increasing to 80% among those aged 80 years or older. Low back pain is a common symptom of lumbar DDD; neck and arm pain are common symptoms of cervical DDD. Nonsurgical treatments can be used to relieve pain and minimize disability associated with DDD. However, it is estimated that about 10% to 20% of people with lumbar DDD and up to 30% with cervical DDD will be unresponsive to nonsurgical treatments. In these cases, surgical treatment is considered. Spinal fusion (arthrodesis) is the process of fusing or joining 2 bones and is considered the surgical gold standard for DDD. Artificial disc replacement is the replacement of the degenerated intervertebral disc with an artificial disc in people with DDD of the lumbar or cervical spine that has been unresponsive to nonsurgical treatments for at least 6 months. Unlike spinal fusion, ADR preserves movement of the spine, which is thought to reduce or prevent the development of adjacent segment degeneration. Additionally, a bone graft is not required for ADR, and this alleviates complications, including bone graft donor site pain and pseudoarthrosis. It is estimated that about 5% of patients who require surgery for DDD will be candidates for ADR. Review Strategy The Medical Advisory Secretariat conducted a computerized search of the literature published between 2003 and September 2005 to answer the following questions: What is the effectiveness of ADR in people with DDD of the lumbar or cervical regions of the spine compared with spinal fusion surgery? Does an artificial disc reduce the incidence of adjacent segment degeneration (ASD

  19. Disc erosion in Models 103 and 104 of Beall mitral valve prostheses

    PubMed Central

    Gómez, Ricardo; Verduras, María José; Lopez-Quintana, Alfonso; Riera, Luis; Zerolo, Ignacio; Martinez-Bordiu, Cristóbal

    1981-01-01

    Three cases of severe disc variance and erosion of the Teflon-disc Beall mitral valve prosthesis (Models 103 and 104) are reported. In two patients, the Beall mitral valves were excised and replaced with two Björk-Shiley mitral valves. The remaining patient did not survive, and at autopsy, the lens was found at the aortic bifurcation level. Because of this potentially lethal complication, careful follow-up of patients with Beall mitral valve prostheses (Models 103 and 104) is recommended. Images PMID:15216211

  20. Toxicology: pearls and pitfalls in the use of antidotes.

    PubMed

    Smollin, Craig G

    2010-02-01

    Although most poisonings require only supportive care, the emergency physician must recognize when the use of an antidote is required, and understand the risks and benefits of the treatment rendered. Although the more commonly instituted specific therapy in acute poisoning is the administration of intravenous fluids followed by the administration of oxygen, in certain circumstances prompt administration of a specific antidote may be required, and failure to identify these circumstances may lead to significant morbidity or mortality. This article describes select antidotes, and discusses their indications and potential pitfalls.

  1. Principles and Pitfalls: a Guide to Death Certification

    PubMed Central

    Brooks, Erin G.; Reed, Kurt D.

    2015-01-01

    Death certificates serve the critical functions of providing documentation for legal/administrative purposes and vital statistics for epidemiologic/health policy purposes. In order to satisfy these functions, it is important that death certificates be filled out completely, accurately, and promptly. The high error rate in death certification has been documented in multiple prior studies, as has the effectiveness of educational training interventions at mitigating errors. The following guide to death certification is intended to illustrate some basic principles and common pitfalls in electronic death registration with the goal of improving death certification accuracy. PMID:26185270

  2. How group practices can avoid managed care contracting pitfalls.

    PubMed

    Gosfield, A G

    1999-07-01

    When negotiating contracts with managed care organizations, group practices should understand the potential pitfalls involved. The basic issues to be aware of are understanding the relative parties' negotiating positions, the business significance of fundamental terms, and the actual contract provisions. The most important clauses in contracts concern compensation and termination. Group practices should require that their contracts include clauses that provide the physicians with protection should utilization assumptions not be met. They also should be realistic about their ability to fulfill contract terms. In addition, contract terms should be clearly written, well-defined, and time-limited.

  3. Grant-Writing Pearls and Pitfalls: Maximizing Funding Opportunities.

    PubMed

    Liu, Jeffrey C; Pynnonen, Melissa A; St John, Maie; Rosenthal, Eben L; Couch, Marion E; Schmalbach, Cecelia E

    2016-02-01

    This invited article reviews the grant process to include the following objectives: (1) to provide an understanding of otolaryngology funding mechanisms in the context of career progression; (2) to outline key components of a well-written grant; (3) to highlight vital members of a successful research team, with emphasis on the mentor-mentee relationship; and (4) to clarify grant scoring with emphasis on common pitfalls to avoid. Current otolaryngology funding mechanisms and up-to-date resources are provided. The review is aimed to assist otolaryngology residents, faculty new to the grant process, as well as experienced researchers striving to improve their grant review scores.

  4. Lost in Translation: Pitfalls in Deciphering Plant Alternative Splicing Transcripts

    PubMed Central

    Brown, John W.S.; Simpson, Craig G.; Marquez, Yamile; Gadd, Geoffrey M.; Barta, Andrea; Kalyna, Maria

    2015-01-01

    Transcript annotation in plant databases is incomplete and often inaccurate, leading to misinterpretation. As more and more RNA-seq data are generated, plant scientists need to be aware of potential pitfalls and understand the nature and impact of specific alternative splicing transcripts on protein production. A primary area of concern and the topic of this article is the (mis)annotation of open reading frames and premature termination codons. The basic message is that to adequately address expression and functions of transcript isoforms, it is necessary to be able to predict their fate in terms of whether protein isoforms are generated or specific transcripts are unproductive or degraded. PMID:26286536

  5. Cultural diversity in nursing education: perils, pitfalls, and pearls.

    PubMed

    Bednarz, Hedi; Schim, Stephanie; Doorenbos, Ardith

    2010-05-01

    Increasing diversity in the classroom challenges nursing educators to identify issues that complicate teaching (perils), analyze barriers for themselves and their students (pitfalls), and select new strategies for working with nontraditional students (pearls). This article identifies concerns arising from attitudes and values within nursing and common approaches to diversity education, and then discusses key issues in nursing education that relate to human nature, culture, faculty workload, and student demographics. Finally, some strategies are proposed for increasing the effectiveness of professional preparation with diverse students through a focus on culturally congruent education and development of faculty cultural competence.

  6. The seven common pitfalls of customer service in hospitals.

    PubMed

    Domingo, Rene T

    2015-01-01

    Operating simultaneously like a repair shop, prison, and hotel, hospitals are prone to seven common pitfalls in customer service. Patient care is often fragmented, inscrutable, inflexible, insensitive, reactive, myopic, and unsafe. Hospitals are vying to be more high-tech, rather than high-touch even though staff engagement with patients rather than facilities and equipment strongly influence patient satisfaction. Unless processes, policies, and people are made customer-centered, the high quality of the hospital's human and hardware resources will not translate into high patient satisfaction and patient loyalty.

  7. Cultural Diversity in Nursing Education: Perils, Pitfalls, and Pearls

    PubMed Central

    Bednarz, Hedi; Schim, Stephanie; Doorenbos, Ardith

    2010-01-01

    Increasing diversity in the classroom challenges nursing educators to identify issues that complicate teaching (perils), analyze barriers for themselves and their students (pitfalls), and select new strategies for working with nontraditional students (pearls). This article identifies concerns arising from attitudes and values within nursing and common approaches to diversity education, and then discusses key issues in nursing education that relate to human nature, culture, faculty workload, and student demographics. Finally, some strategies are proposed for increasing the effectiveness of professional preparation with diverse students through a focus on culturally congruent education and development of faculty cultural competence. PMID:20143759

  8. Dropped gallstones: spectrum of imaging findings, complications and diagnostic pitfalls.

    PubMed

    Nayak, L; Menias, C O; Gayer, G

    2013-08-01

    Spillage of gallstones into the abdominal cavity, referred to as "dropped gallstones" (DGs), occurs commonly during laparoscopic cholecystectomy. The majority of these spilled stones remain clinically silent; however, if uncomplicated DGs are not correctly identified on subsequent imaging, they may mimic peritoneal implants and cause unduly concern. A small percentage of DGs cause complications, including abscess and fistula formation. Recognising the DG within the abscess is critical for definitive treatment. This pictorial review illustrates the imaging appearances and complications of DGs on CT, MRI and ultrasound and emphasises pitfalls in diagnosis.

  9. Pitfalls in ictal EEG interpretation: critical care and intracranial recordings.

    PubMed

    Gaspard, Nicolas; Hirsch, Lawrence J

    2013-01-01

    EEG is the cornerstone examination for seizure diagnosis, especially nonconvulsive seizures in the critically ill, but is still subject to many errors that can lead to a wrong diagnosis and unnecessary or inadequate treatment. Many of these pitfalls to EEG interpretation are avoidable. This article reviews common errors in EEG interpretation, focusing on ictal or potentially ictal recordings obtained in critically ill patients. Issues discussed include artifacts, nonepileptic events, equivocal EEG patterns seen in comatose patients, and quantitative EEG artifacts. This review also covers some difficulties encountered with intracranial EEG recordings in patients undergoing epilepsy surgery, including issues related to display resolution.

  10. Pitfalls and Limitations of Radionuclide Hepatobiliary and Gastrointestinal System Imaging.

    PubMed

    Low, Chen Sheng; Ahmed, Haseeb; Notghi, Alp

    2015-11-01

    Radionuclide imaging for the hepatobiliary and gastrointestinal system covers a wide range of different indications and imaging techniques. This wide variety allows the different functional assessments of both systems. Therefore, the understanding of each technique and its indications is essential. Cholescintigraphy is a well-established method in the assessment of acute and chronic cholecystitis. It also has a role in the detection of biliary atresia. The assessment of gastrointestinal transit is also well-established in radionuclide imaging for functional investigation of the gastrointestinal tract. Furthermore, detection of acute gastrointestinal bleeding with radionuclide imaging is also standard practice. This article aims to review the pitfalls and limitations in all of these areas.

  11. Single-pool exponential decomposition models: potential pitfalls in their use in ecological studies.

    PubMed

    Adair, E Carol; Hobbie, Sarah E; Hobbie, Russell K

    2010-04-01

    The importance of litter decomposition to carbon and nutrient cycling has motivated substantial research. Commonly, researchers fit a single-pool negative exponential model to data to estimate a decomposition rate (k). We review recent decomposition research, use data simulations, and analyze real data to show that this practice has several potential pitfalls. Specifically, two common decisions regarding model form (how to model initial mass) and data transformation (log-transformed vs. untransformed data) can lead to erroneous estimates of k. Allowing initial mass to differ from its true, measured value resulted in substantial over- or underestimation of k. Log-transforming data to estimate k using linear regression led to inaccurate estimates unless errors were lognormally distributed, while nonlinear regression of untransformed data accurately estimated k regardless of error structure. Therefore, we recommend fixing initial mass at the measured value and estimating k with nonlinear regression (untransformed data) unless errors are demonstrably lognormal. If data are log-transformed for linear regression, zero values should be treated as missing data; replacing zero values with an arbitrarily small value yielded poor k estimates. These recommendations will lead to more accurate k estimates and allow cross-study comparison of k values, increasing understanding of this important ecosystem process.

  12. Qualifying stem cell sources: how to overcome potential pitfalls in regenerative medicine?

    PubMed

    Reinke, Simon; Dienelt, Anke; Blankenstein, Antje; Duda, Georg N; Geissler, Sven

    2016-01-01

    Regenerative medicine aims to replace lost cells and to restore damaged tissues and organs by either tissue-engineering approaches or stimulation of endogenous processes. Due to their biological properties, stem cells promise to be an effective source for such strategies. Especially adult multipotent stem cells (ASCs) are believed to be applicable in a broad range of therapies for the treatment of multifactorial diseases or age-related degeneration, although the molecular and cellular mechanisms underlying their regenerative function are often hardly described. Moreover, in some demanding clinical situations their efficiency remains limited. Thus, a basic understanding of ASCs regenerative function, their complex interplay with their microenvironment and how compromising conditions interfere with their efficiency is mandatory for any regenerative strategy. Concerning this matter, the impact of patient-specific constraints are often underestimated in research projects and their influence on the study results disregarded. Thus, researchers are urgently depending on well-characterized tissue samples or cells that are connected with corresponding donor information, such as secondary diseases, medication. Here, we outline principle pitfalls during experimental studies using human samples, and describe a potential strategy to overcome these challenges by establishing a core unit for cell and tissue harvesting. This facility aims to bridge the gap between clinic and research laboratories by the provision of a direct link to the clinical operating theatres. Such a strategy clearly supports basic and clinical research in the conduct of their studies and supplies highly characterized human samples together with the corresponding donor information.

  13. Proto-planetary disc evolution and dispersal

    NASA Astrophysics Data System (ADS)

    Rosotti, Giovanni Pietro

    2015-05-01

    Planets form from gas and dust discs in orbit around young stars. The timescale for planet formation is constrained by the lifetime of these discs. The properties of the formed planetary systems depend thus on the evolution and final dispersal of the discs, which is the main topic of this thesis. Observations reveal the existence of a class of discs called "transitional", which lack dust in their inner regions. They are thought to be the last stage before the complete disc dispersal, and hence they may provide the key to understanding the mechanisms behind disc evolution. X-ray photoevaporation and planet formation have been studied as possible physical mechanisms responsible for the final dispersal of discs. However up to now, these two phenomena have been studied separately, neglecting any possible feedback or interaction. In this thesis we have investigated what is the interplay between these two processes. We show that the presence of a giant planet in a photo-evaporating disc can significantly shorten its lifetime, by cutting the inner regions from the mass reservoir in the exterior of the disc. This mechanism produces transition discs that for a given mass accretion rate have larger holes than in models considering only X-ray photo-evaporation, constituting a possible route to the formation of accreting transition discs with large holes. These discs are found in observations and still constitute a puzzle for the theory. Inclusion of the phenomenon called "thermal sweeping", a violent instability that can destroy a whole disc in as little as 10 4 years, shows that the outer disc left can be very short-lived (depending on the X-ray luminosity of the star), possibly explaining why very few non accreting transition discs are observed. However the mechanism does not seem to be efficient enough to reconcile with observations. In this thesis we also show that X-ray photo-evaporation naturally explains the observed correlation between stellar masses and accretion

  14. Radiation Source Replacement Workshop

    SciTech Connect

    Griffin, Jeffrey W.; Moran, Traci L.; Bond, Leonard J.

    2010-12-01

    This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

  15. [Polish nomenclature of lumbar disc disease].

    PubMed

    Radło, Paweł; Smetkowski, Andrzej; Tesiorowski, Maciej

    2014-01-01

    Lumbar disc herniation is one of the most common damage of musculoskeletal system. The incidence of pain of lumbosacral spine is estimated approximately on 60-90% in general population, whereas the incidence of disc herniation in patients experiencing low back pain is about 91%. Despite the high incidence and uncomplicated pathogenesis of disc disease there is a problem with the nomenclature. In the vast majority of cases, the naming confusion stems from ignorance of the etiology of low back pain. Different terminologies: morphological, topographical, Radiological and Clinical are used interchangeably. In addition, diagnosis is presented in a variety of languages: Polish, English and Latin. Moreover, the medical and traditional language are used alternately. The authors found in Polish literature more, than 20 terms to describe lumbar disc herniation. All of these terms in the meaning of the authors are used to determine one pathology--mechanical damage to the intervertebral disc and moving the disc material beyond the anatomical area.

  16. Close-packing of growing discs

    SciTech Connect

    Bursill, L.A.; Xudong, F. . School of Physics)

    1988-12-01

    Spiral lattices are derived by allowing growing discs to aggregate under a close-packing rule. Both Fibonacci and Lucas numbers of visible spirals arise naturally, dependent only on the choice of growth centre. Both the rate of convergence towards an ideal spiral, and chirality, are determined by the initial placement of the first few discs (initial conditions). Thus the appearance of spiral packings is no more or less mysterious than the appearance of hexagonal packed arrays of equal discs.

  17. Pitfalls of CITES implementation in Nepal: a policy gap analysis.

    PubMed

    Dongol, Yogesh; Heinen, Joel T

    2012-08-01

    Implementation of policy involves multiple agencies operating at multiple levels in facilitating processes and actions to accomplish desired results. The Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES) was developed and implemented to regulate and control international wildlife trade, but violations of the agreement are widespread and growing worldwide, including in Nepal. This study attempts to understand how domestic CITES policies are translated into action and what effect actions and processes have on compliance. In doing so, this study provides insights into the implementation and enforcement pitfalls of national legislation that explain CITES violations in Nepal. Primarily, we used 26 key informants interviews to learn opinions of experts, and the grounded theory approach for further qualitative data analysis. In addition, we used Najman's (1995) policy implementation analysis framework to explain gaps. Many interrelated variables in the content of the policy, commitment and capacity of the agencies, the roles of clients and coalitions and contextual issues were observed. Variables that emerged suggest pitfalls in the regulatory policy represented by low probability of detection, arrest and punishment. Moreover, redistributive policies in buffer zones of protected areas are needed into perpetuity to benefit locals. Also, conservation organizations' support for building public and political salience is imperative.

  18. Pitfalls of CITES Implementation in Nepal: A Policy Gap Analysis

    NASA Astrophysics Data System (ADS)

    Dongol, Yogesh; Heinen, Joel T.

    2012-08-01

    Implementation of policy involves multiple agencies operating at multiple levels in facilitating processes and actions to accomplish desired results. The Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES) was developed and implemented to regulate and control international wildlife trade, but violations of the agreement are widespread and growing worldwide, including in Nepal. This study attempts to understand how domestic CITES policies are translated into action and what effect actions and processes have on compliance. In doing so, this study provides insights into the implementation and enforcement pitfalls of national legislation that explain CITES violations in Nepal. Primarily, we used 26 key informants interviews to learn opinions of experts, and the grounded theory approach for further qualitative data analysis. In addition, we used Najman's (1995) policy implementation analysis framework to explain gaps. Many interrelated variables in the content of the policy, commitment and capacity of the agencies, the roles of clients and coalitions and contextual issues were observed. Variables that emerged suggest pitfalls in the regulatory policy represented by low probability of detection, arrest and punishment. Moreover, redistributive policies in buffer zones of protected areas are needed into perpetuity to benefit locals. Also, conservation organizations' support for building public and political salience is imperative.

  19. Big data in sleep medicine: prospects and pitfalls in phenotyping.

    PubMed

    Bianchi, Matt T; Russo, Kathryn; Gabbidon, Harriett; Smith, Tiaundra; Goparaju, Balaji; Westover, M Brandon

    2017-01-01

    Clinical polysomnography (PSG) databases are a rich resource in the era of "big data" analytics. We explore the uses and potential pitfalls of clinical data mining of PSG using statistical principles and analysis of clinical data from our sleep center. We performed retrospective analysis of self-reported and objective PSG data from adults who underwent overnight PSG (diagnostic tests, n=1835). Self-reported symptoms overlapped markedly between the two most common categories, insomnia and sleep apnea, with the majority reporting symptoms of both disorders. Standard clinical metrics routinely reported on objective data were analyzed for basic properties (missing values, distributions), pairwise correlations, and descriptive phenotyping. Of 41 continuous variables, including clinical and PSG derived, none passed testing for normality. Objective findings of sleep apnea and periodic limb movements were common, with 51% having an apnea-hypopnea index (AHI) >5 per hour and 25% having a leg movement index >15 per hour. Different visualization methods are shown for common variables to explore population distributions. Phenotyping methods based on clinical databases are discussed for sleep architecture, sleep apnea, and insomnia. Inferential pitfalls are discussed using the current dataset and case examples from the literature. The increasing availability of clinical databases for large-scale analytics holds important promise in sleep medicine, especially as it becomes increasingly important to demonstrate the utility of clinical testing methods in management of sleep disorders. Awareness of the strengths, as well as caution regarding the limitations, will maximize the productive use of big data analytics in sleep medicine.

  20. Accretion Discs Show Their True Colours

    NASA Astrophysics Data System (ADS)

    2008-07-01

    Quasars are the brilliant cores of remote galaxies, at the hearts of which lie supermassive black holes that can generate enough power to outshine the Sun a trillion times. These mighty power sources are fuelled by interstellar gas, thought to be sucked into the hole from a surrounding 'accretion disc'. A paper in this week's issue of the journal Nature, partly based on observations collected with ESO's Very Large Telescope, verifies a long-standing prediction about the intensely luminous radiation emitted by these accretion discs. Uncovering the disc ESO PR Photo 21/08 Uncovering the inner disc "Astronomers were puzzled by the fact that the best models of these discs couldn't quite be reconciled with some of the observations, in particular, with the fact that these discs did not appear as blue as they should be," explains lead-author Makoto Kishimoto. Such a discrepancy could be the signal that there was something very wrong with the models. With his colleagues, he investigated this discrepancy by studying the polarised light from six quasars. This enabled them to demonstrate that the disc spectrum is as blue as predicted. "The crucial observational difficulty here has been that the disc is surrounded by a much larger torus containing hot dust, whose light partly outshines that of the disc," says Kishimoto. "Because the light coming from the disc is scattered in the disc vicinity and thus polarised, by observing only polarised light from the quasars, one can uncover the buried light from the disc." In a similar way that a fisherman would wear polarised sunglasses to help get rid of the glare from the water surface and allow him to see more clearly under the water, the filter on the telescope allowed the astronomers to see beyond surrounding clouds of dust and gas to the blue colour of the disc in infrared light. The observations were done with the FORS and ISAAC instruments on one of the 8.2-m Unit Telescopes of ESO's Very Large Telescope, located in the Atacama

  1. The quiescent phase of galactic disc growth

    NASA Astrophysics Data System (ADS)

    Aumer, Michael; Binney, James; Schönrich, Ralph

    2016-07-01

    We perform a series of controlled N-body simulations of growing disc galaxies within non-growing, live dark matter haloes of varying mass and concentration. Our initial conditions include either a low-mass disc or a compact bulge. New stellar particles are continuously added on near-circular orbits to the existing disc, so spiral structure is continuously excited. To study the effect of combined spiral and giant molecular cloud (GMC) heating on the discs, we introduce massive, short-lived particles that sample a GMC mass function. An isothermal gas component is introduced for a subset of the models. We perform a resolution study and vary parameters governing the GMC population, the histories of star formation and radial scale growth. Models with GMCs and standard values for the disc mass and halo density provide the right level of self-gravity to explain the age-velocity dispersion relation of the solar neighbourhood (Snhd). GMC heating generates remarkably exponential vertical profiles with scaleheights that are radially constant and agree with observations of galactic thin discs. GMCs are also capable of significantly delaying bar formation. The amount of spiral-induced radial migration agrees with what is required for the metallicity distribution of the Snhd. However, in our standard models, the outward-migrating populations are not hot enough vertically to create thick discs. Thick discs can form in models with high baryon fractions, but the corresponding bars are too long, the young stellar populations too hot and the discs flare considerably.

  2. Development of injectable hydrogels for nucleus pulposus replacement

    NASA Astrophysics Data System (ADS)

    Thomas, Jonathan D.

    Intervertebral disc degeneration has been reported as the underlying cause for 75% of cases of lower back pain and is marked by dehydration of the nucleus pulposus within the intervertebral disc. There have been many implant designs to replace the nucleus pulposus. Some researchers have proposed the replacement of the nucleus pulposus with hydrogel materials. The insertion of devices made from these materials further compromises the annulus of the disc. An ideal nucleus replacement could be injected into the disc space and form a solid in vivo. However, injectable replacements using curing elastomers and thermoplastic materials are not ideal because of the potentially harmful exothermic heat evolved from their reactions and the toxicity of the reactants used. We propose a hydrogel system that can be injected as a liquid at 25°C and solidified to yield a hydrogel within the intervertebral disc at 37°C. In aqueous solutions, these polymers have Lower Critical Solution Temperatures (LCST) between 25-37°C, making them unique candidate materials for this application. Poly(N-isopropylacrylamide) (PNIPAAm) is the most widely studied LCST polymer due to its drastic transition near body temperature. However, by itself, pure PNIPAAm forms a hydrogel that has low water content and can readily undergo plastic deformation. To increase the water content and impart elasticity to PNIPAAm hydrogels, grafted and branched hydrogel systems were created that incorporated the thermogelling PNIPAAm and hydrophilic poly(ethylene glycol) (PEG). In this research, the effects of polymer composition and monomer to initiator ratio, which controls polymer MW, on the in vitro swelling properties (mass, chemical, and compressive mechanical stability) of hydrogels formed from aqueous solutions of these polymers were evaluated. Immersion studies were also conducted in solutions to simulate the osmotic environment of the nucleus pulposus. The effects of repeated compression and unloading cycles

  3. Circumplanetary discs around young giant planets: a comparison between core-accretion and disc instability

    NASA Astrophysics Data System (ADS)

    Szulágyi, J.; Mayer, L.; Quinn, T.

    2017-01-01

    Circumplanetary discs can be found around forming giant planets, regardless of whether core accretion or gravitational instability built the planet. We carried out state-of-the-art hydrodynamical simulations of the circumplanetary discs for both formation scenarios, using as similar initial conditions as possible to unveil possible intrinsic differences in the circumplanetary disc mass and temperature between the two formation mechanisms. We found that the circumplanetary discs' mass linearly scales with the circumstellar disc mass. Therefore, in an equally massive protoplanetary disc, the circumplanetary discs formed in the disc instability model can be only a factor of 8 more massive than their core-accretion counterparts. On the other hand, the bulk circumplanetary disc temperature differs by more than an order of magnitude between the two cases. The subdiscs around planets formed by gravitational instability have a characteristic temperature below 100 K, while the core-accretion circumplanetary discs are hot, with temperatures even greater than 1000 K when embedded in massive, optically thick protoplanetary discs. We explain how this difference can be understood as the natural result of the different formation mechanisms. We argue that the different temperatures should persist up to the point when a full-fledged gas giant forms via disc instability; hence, our result provides a convenient criterion for observations to distinguish between the two main formation scenarios by measuring the bulk temperature in the planet vicinity.

  4. Grain charging in protoplanetary discs

    NASA Astrophysics Data System (ADS)

    Ilgner, M.

    2012-02-01

    Context. Recent work identified a growth barrier for dust coagulation that originates in the electric repulsion between colliding particles. Depending on its charge state, dust material may have the potential to control key processes towards planet formation such as magnetohydrodynamic (MHD) turbulence and grain growth, which are coupled in a two-way process. Aims: We quantify the grain charging at different stages of disc evolution and differentiate between two very extreme cases: compact spherical grains and aggregates with fractal dimension Df = 2. Methods: Applying a simple chemical network that accounts for collisional charging of grains, we provide a semi-analytical solution. This allowed us to calculate the equilibrium population of grain charges and the ionisation fraction efficiently. The grain charging was evaluated for different dynamical environments ranging from static to non-stationary disc configurations. Results: The results show that the adsorption/desorption of neutral gas-phase heavy metals, such as magnesium, effects the charging state of grains. The greater the difference between the thermal velocities of the metal and the dominant molecular ion, the greater the change in the mean grain charge. Agglomerates have more negative excess charge on average than compact spherical particles of the same mass. The rise in the mean grain charge is proportional to N1/6 in the ion-dust limit. We find that grain charging in a non-stationary disc environment is expected to lead to similar results. Conclusions: The results indicate that the dust growth and settling in regions where the dust growth is limited by the so-called "electro-static barrier" do not prevent the dust material from remaining the dominant charge carrier.

  5. [Standardized terminology for disc disease].

    PubMed

    Sánchez Pérez, M; Gil Sierra, A; Sánchez Martín, A; Gallego Gómez, P; Pereira Boo, D

    2012-01-01

    This article reviews the terminology used to describe morphological alterations in the intervertebral discs. Radiologists must be able to communicate information about the type, location, and severity of these alterations to medical and surgical clinicians. It is crucial to use simple, standard, and unified terminology to ensure comprehension not only among radiologists but also with professionals from the different specialties for whom the radiology reports are written (fundamentally traumatologists and neurosurgeons). This terminology will help ensure a more accurate diagnosis and better patient management.

  6. Pattern reorganization occurs independently of cell division during Drosophila wing disc regeneration in situ.

    PubMed

    Díaz-García, Sandra; Baonza, Antonio

    2013-08-06

    One of the most intriguing problems in developmental biology is how an organism can replace missing organs or portions of its body after injury. This capacity, known as regeneration, is conserved across different phyla. The imaginal discs of Drosophila melanogaster provide a particularly well-characterized model for analyzing regeneration. We have developed a unique method to study organ regeneration under physiological conditions using the imaginal discs of Drosophila. Using this method, we revisited different aspects of organ regeneration. The results presented in this report suggest that during the initial stages of regeneration, different processes occur, including wound healing, a temporary loss of markers of cell-fate commitment, and pattern reorganization. We present evidence indicating that all of these processes occur even when cell division has been arrested. Our data also suggested that Wingless is not required during the early stages of disc regeneration.

  7. Pattern reorganization occurs independently of cell division during Drosophila wing disc regeneration in situ

    PubMed Central

    Díaz-García, Sandra; Baonza, Antonio

    2013-01-01

    One of the most intriguing problems in developmental biology is how an organism can replace missing organs or portions of its body after injury. This capacity, known as regeneration, is conserved across different phyla. The imaginal discs of Drosophila melanogaster provide a particularly well-characterized model for analyzing regeneration. We have developed a unique method to study organ regeneration under physiological conditions using the imaginal discs of Drosophila. Using this method, we revisited different aspects of organ regeneration. The results presented in this report suggest that during the initial stages of regeneration, different processes occur, including wound healing, a temporary loss of markers of cell-fate commitment, and pattern reorganization. We present evidence indicating that all of these processes occur even when cell division has been arrested. Our data also suggested that Wingless is not required during the early stages of disc regeneration. PMID:23878228

  8. Total Hip Replacement

    MedlinePlus

    ... ankle pump exercises, and early mobilization. Leg-length Inequality Sometimes after a hip replacement, one leg may ... Surgeons (AAOS). To learn more about your orthopaedic health, please visit orthoinfo.org. Page ( 12 ) AAOS does ...

  9. Ankle replacement - discharge

    MedlinePlus

    You had an ankle replacement. Your surgeon removed and reshaped damaged bones, and put in an artificial ankle joint. You received pain medicine and were shown how to treat swelling around your new ankle joint.

  10. Replacing a Missing Tooth

    MedlinePlus

    ... This may be accomplished by adding plastic or porcelain filling material or a porcelain crown to reshape its appearance. What options are ... there is no danger of nerve involvement. A porcelain replacement tooth is held in place by metal ...

  11. Carbohydrates as Fat Replacers.

    PubMed

    Peng, Xingyun; Yao, Yuan

    2017-02-28

    The overconsumption of dietary fat contributes to various chronic diseases, which encourages attempts to develop and consume low-fat foods. Simple fat reduction causes quality losses that impede the acceptance of foods. Fat replacers are utilized to minimize the quality deterioration after fat reduction or removal to achieve low-calorie, low-fat claims. In this review, the forms of fats and their functions in contributing to food textural and sensory qualities are discussed in various food systems. The connections between fat reduction and quality loss are described in order to clarify the rationales of fat replacement. Carbohydrate fat replacers usually have low calorie density and provide gelling, thickening, stabilizing, and other texture-modifying properties. In this review, carbohydrates, including starches, maltodextrins, polydextrose, gums, and fibers, are discussed with regard to their interactions with other components in foods as well as their performances as fat replacers in various systems.

  12. Use NASA GES DISC Data in ArcGIS

    NASA Technical Reports Server (NTRS)

    Yang, Wenli; Pham, Long B.; Kempler, Steve

    2015-01-01

    This presentation describes GIS relevant data at NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), GES DISC Services and Support for GIS Users, and use cases of GES DISC data in ArcGIS.

  13. Leaf-disc grafting for the transmission of Candidatus Liberibacter asiaticus in citrus (Citrus sinensis; Rutaceae) seedlings1

    PubMed Central

    Tabay Zambon, Flavia; Plant, Karen; Etxeberria, Ed

    2017-01-01

    Premise of the study: The search for resistance/tolerance to the devastating citrus huanglongbing disease (syn. HLB or citrus greening) is generating an increasing number of new plants of diverse genetic makeup. As the increasing number of new plants require more space, resources, and time, the need for faster and more efficient HLB screening tests becomes crucial. Methods and Results: The leaf-disc grafting system described here consists in replacing a disc of leaf tissue with a similar disc from an infected plant. This can be performed in young seedlings not yet big enough to endure other types of grafting. Graft success and infection rates average approximately 80%. Conclusions: We describe the successful adaptation of leaf-disc grafting as a powerful screening tool for HLB. The system requires minimal plant material and can be performed in seedlings at a very young age with increased efficiency in terms of time, space, and resources. PMID:28090406

  14. Androgen replacement for women.

    PubMed Central

    Basson, R.

    1999-01-01

    OBJECTIVES: To determine whether a postmenopausal syndrome comprising specific changes in sexual desire and response associated with low free testosterone exists. To determine whether this syndrome is ameliorated by testosterone replacement. QUALITY OF EVIDENCE: Literature documenting that replacement of physiological levels of testosterone is beneficial and safe is scant. Only one randomized prospective blinded study examines sexual outcome in detail. MAIN MESSAGE: Testosterone is an important metabolic and sex hormone produced by the ovary throughout life. The variable reduction in ovarian testosterone production coincident with menopause is sometimes associated with a syndrome of specific changes in sexual desire and sexual response. Estrogen deficiency also impairs sexual response, but its replacement will not improve and might exacerbate sexual symptoms from androgen loss. Diagnosis of androgen deficiency is clinical, based on accurate assessment of a woman's sexual status before and after menopause and only confirmed (rather than diagnosed) by a low level of free testosterone. Partial androgen replacement restores much of the sexual response and facilitates sexual desire that is triggered by external cues. Avoiding supraphysiological levels of testosterone lessens risk of masculinization. Avoiding alkylated testosterone lessens hepatic or lipid impairment. CONCLUSION: Further prospective randomized studies of replacement of physiological levels of testosterone in women with androgen deficiency syndrome are needed, using formulations of testosterone available in Canada. The consistency of sexual changes, the associated personal and relationship distress, together with our clinical experience of the gratifying response to physiological replacement, make further studies urgently needed. PMID:10509222

  15. Development of a rapid matrix digestion technique for ultrastructural analysis of elastic fibers in the intervertebral disc.

    PubMed

    Tavakoli, Javad; Costi, John J

    2017-03-21

    Collagen and elastic fibers are two major fibrous constituents of the annulus fibrosus (AF) in the disc that contribute to its mechanical and viscoelastic properties. It was thought that elastic fibers play no substantial role in the function and properties of the disc as these fibers were irregularly distributed. Studies that have revealed highly organized elastic fibers with different regional orientation and distribution, while being strongly crosslinked with matrix, suggesting their contribution to disc structure-function properties. These studies that were performed by light microscopic analysis of histologically prepared samples, have not been able to reveal the fine-scale architectural details of the elastic fiber network. Since elastic fibers are intermingled with other fibrous components of the disc and mostly obscured by the extracellular matrix, it is difficult to demonstrate their ultra-structural organization using scanning electron microscopy (SEM). Therefore the aim of this study was to develop a rapid matrix digestion technique for ultrastructural analysis of the disc elastic fibers. This study provides a new method for fundamental visualization of elastic fibers and their architecture in the disc. Through the ultra-structural analysis, the relationship between structure and function, as well as the role of elastic fibers on AF mechanical properties can be studied. This method may be used to develop a three-dimensional map of elastic fibers distribution within the disc, which would provide valuable information for designing tissue engineered scaffolds for AF repair and replacement.

  16. Spiral Waves in Accretion Discs - Theory

    NASA Astrophysics Data System (ADS)

    Boffin, H. M. J.

    Spirals shocks have been widely studied in the context of galactic dynamics and protostellar discs. They may however also play an important role in some classes of close binary stars, and more particularly in cataclysmic variables. In this paper, we review the physics of spirals waves in accretion discs, present the results of numerical simulations and consider whether theory can be reconcilied with observations.

  17. Circular plate capacitor with different discs

    NASA Astrophysics Data System (ADS)

    Paffuti, Giampiero; Cataldo, Enrico; Di Lieto, Alberto; Maccarrone, Francesco

    2016-10-01

    In this paper, we write a system of integral equations for a capacitor composed of two discs of different radii, generalizing Love's equation for equal discs. We compute the complete asymptotic form of the capacitance matrix for both large and small distances obtaining a generalization of Kirchhoff's formula for the latter case.

  18. 46 CFR 64.61 - Rupture disc.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Rupture disc. 64.61 Section 64.61 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.61 Rupture disc. If a rupture...

  19. 46 CFR 64.61 - Rupture disc.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Rupture disc. 64.61 Section 64.61 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.61 Rupture disc. If a rupture...

  20. 46 CFR 64.61 - Rupture disc.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Rupture disc. 64.61 Section 64.61 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.61 Rupture disc. If a rupture...

  1. 46 CFR 64.61 - Rupture disc.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Rupture disc. 64.61 Section 64.61 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.61 Rupture disc. If a rupture...

  2. 46 CFR 64.61 - Rupture disc.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Rupture disc. 64.61 Section 64.61 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.61 Rupture disc. If a rupture...

  3. The inner cavity of the circumnuclear disc

    NASA Astrophysics Data System (ADS)

    Blank, M.; Morris, M. R.; Frank, A.; Carroll-Nellenback, J. J.; Duschl, W. J.

    2016-06-01

    The circumnuclear disc (CND) orbiting the Galaxy's central black hole is a reservoir of material that can ultimately provide energy through accretion, or form stars in the presence of the black hole, as evidenced by the stellar cluster that is presently located at the CND's centre. In this paper, we report the results of a computational study of the dynamics of the CND. The results lead us to question two paradigms that are prevalent in previous research on the Galactic Centre. The first is that the disc's inner cavity is maintained by the interaction of the central stellar cluster's strong winds with the disc's inner rim, and secondly, that the presence of unstable clumps in the disc implies that the CND is a transient feature. Our simulations show that, in the absence of a magnetic field, the interaction of the wind with the inner disc rim actually leads to a filling of the inner cavity within a few orbital time-scales, contrary to previous expectations. However, including the effects of magnetic fields stabilizes the inner disc rim against rapid inward migration. Furthermore, this interaction causes instabilities that continuously create clumps that are individually unstable against tidal shearing. Thus the occurrence of such unstable clumps does not necessarily mean that the disc is itself a transient phenomenon. The next steps in this investigation are to explore the effect of the magnetorotational instability on the disc evolution and to test whether the results presented here persist for longer time-scales than those considered here.

  4. Rapid radiative clearing of protoplanetary discs

    NASA Astrophysics Data System (ADS)

    Haworth, Thomas J.; Clarke, Cathie J.; Owen, James E.

    2016-04-01

    The lack of observed transition discs with inner gas holes of radii greater than ˜50 au implies that protoplanetary discs dispersed from the inside out must remove gas from the outer regions rapidly. We investigate the role of photoevaporation in the final clearing of gas from low mass discs with inner holes. In particular, we study the so-called `thermal sweeping' mechanism which results in rapid clearing of the disc. Thermal sweeping was originally thought to arise when the radial and vertical pressure scalelengths at the X-ray heated inner edge of the disc match. We demonstrate that this criterion is not fundamental. Rather, thermal sweeping occurs when the pressure maximum at the inner edge of the dust heated disc falls below the maximum possible pressure of X-ray heated gas (which depends on the local X-ray flux). We derive new critical peak volume and surface density estimates for rapid radiative clearing which, in general, result in rapid dispersal happening less readily than in previous estimates. This less efficient clearing of discs by X-ray driven thermal sweeping leaves open the issue of what mechanism (e.g. far-ultraviolet heating) can clear gas from the outer disc sufficiently quickly to explain the non-detection of cold gas around weak line T Tauri stars.

  5. Shock absorption in lumbar disc prosthesis: a preliminary mechanical study.

    PubMed

    LeHuec, J C; Kiaer, T; Friesem, T; Mathews, H; Liu, M; Eisermann, L

    2003-08-01

    Lumbar disc prostheses have been used in treating symptomatic degenerative disc diseases. A few prostheses of the ball-socket design are currently available for clinical use, the joint mechanism being materialized either with a hard polymer core or a metal-to-metal couple. Other prostheses of "shock absorber" design were not available at the time of the study. The objective of this work was to establish whether there was a difference in the shock absorption capacity between a device having an ultra-high-molecular-weight polyethylene center core and a device having a metal-on-metal bearing. Vibration and shock loading were applied to two lumbar total disc prostheses: PRODISC, manufactured by Spine Solutions, and MAVERICK Total Disc Replacement, manufactured by Medtronic Sofamor Danek. The shock absorption capacity of the device was evaluated by comparing the input and the output force measurements. The disc prosthesis was mounted onto a test apparatus. Each side of the device was equipped with a force sensor. The input shock load and the output resulting forces were simultaneously measured and recorded. The loading force pattern included 1). a static preload of 350 N plus an oscillating vibration of 100 N with frequency sweeping from 0 to 100 Hz and 2). a sudden shock load of 250 N applied over a 0.1-second interval. Both input and output signal data were processed and were transformed into their frequency spectrums. The vibration and shock transmissibility of the device, defined as the ratio of the output spectrum over the input spectrum, were calculated in sweeping the frequency from 0 to 100 Hz. The phase deviation was calculated to characterize the shock absorber effects. For both tested devices under vibration and shock loading, the phase angle displacement between the input and the output signals was 10 degrees. Under oscillating vibration loading, both tested devices had a transmission ratio higher than 99.8%. Over the frequency interval 1-100 Hz, the

  6. About detection of precessing circumpulsar discs

    NASA Astrophysics Data System (ADS)

    Grimani, Catia

    2016-08-01

    Detections of circumpulsar discs and planetary systems through electromagnetic observations appear quite rare. In the case of PSR 1931+24 and B0656+14, the hypothesis of a precessing disc penetrating the pulsar light cylinder is found consistent with radio and gamma observations from these stars. Disc self-occultation and precession may affect electromagnetic measurements. We investigate here under which conditions gravitational waves generated by circumpulsar disc precession may be detected by the proposed second-generation space interferometers DECI-hertz Interferometer Gravitational Wave Observatory and Big Bang Observer. The characteristics of circumpulsar detectable precessing discs are estimated as a function of distance from the Solar system. Speculations on detection rates are presented.

  7. Lumbar Epidural Varix Mimicking Disc Herniation

    PubMed Central

    Bursalı, Adem; Guvenal, Ahmet Burak; Yaman, Onur

    2016-01-01

    Lumbar radiculopathy is generally caused by such well-recognized entity as lumbar disc herniation in neurosurgical practice; however rare pathologies such as thrombosed epidural varix may mimic them by causing radicular symptoms. In this case report, we present a 26-year-old man with the complaint of back and right leg pain who was operated for right L4–5 disc herniation. The lesion interpreted as an extruded disc herniation preoperatively was found to be a thrombosed epidural varix compressing the nerve root preoperatively. The nerve root was decompressed by shrinking the lesion with bipolar thermocoagulation and excision. The patient's complaints disappeared in the postoperative period. Thrombosed lumbar epidural varices may mimic lumbar disc herniations both radiologically and clinically. Therefore, must be kept in mind in the differential diagnosis of lumbar disc herniations. Microsurgical techniques are mandatory for the treatment of these pathologies and decompression with thermocoagulation and excision is an efficient method. PMID:27446525

  8. Strongly magnetized accretion discs require poloidal flux

    NASA Astrophysics Data System (ADS)

    Salvesen, Greg; Armitage, Philip J.; Simon, Jacob B.; Begelman, Mitchell C.

    2016-08-01

    Motivated by indirect observational evidence for strongly magnetized accretion discs around black holes, and the novel theoretical properties of such solutions, we investigate how a strong magnetization state can develop and persist. To this end, we perform local simulations of accretion discs with an initially purely toroidal magnetic field of equipartition strength. We demonstrate that discs with zero net vertical magnetic flux and realistic boundary conditions cannot sustain a strong toroidal field. However, a magnetic pressure-dominated disc can form from an initial configuration with a sufficient amount of net vertical flux and realistic boundary conditions. Our results suggest that poloidal flux is a necessary prerequisite for the sustainability of strongly magnetized accretion discs.

  9. Roentgenographic measurement of lumbar intervertebral disc height.

    PubMed

    Andersson, G B; Schultz, A; Nathan, A; Irstam, L

    1981-01-01

    The influences of differences in both intervertebral motion segment orientations and in reader judgments on measurements of the apparent intervertebral disc heights in lateral roentgenographs of the lumbar spine were examined. Forty-nine roentgenographs were obtained of nine discs that were titled laterally up to +/- 10 degrees, and rotated longitudinally up to +/- 20 degrees. Three orthopaedic surgeons and three radiologists measured disc heights from five of these roentgenographs, all using the same measurement method. The differences in apparent height that resulted from the orientation changes and differences in judgments among the six readers were considerable, usually of the order of one half of the nominal disc height. The results show that, while roentgenographic measurements can be used to estimate disc height, accurate measurements cannot readily be made from routine roentgenographs, and the interpretation should always be cautious.

  10. Merits and Pitfalls of Currently Used Diagnostic Tools in Mycetoma

    PubMed Central

    van de Sande, Wendy W. J.; Fahal, Ahmed H.; Goodfellow, Michael; Mahgoub, El Sheikh; Welsh, Oliverio; Zijlstra, Ed E.

    2014-01-01

    Treatment of mycetoma depends on the causative organism and since many organisms, both actinomycetes (actinomycetoma) and fungi (eumycetoma), are capable of producing mycetoma, an accurate diagnosis is crucial. Currently, multiple diagnostic tools are used to determine the extent of infections and to identify the causative agents of mycetoma. These include various imaging, cytological, histopathological, serological, and culture techniques; phenotypic characterisation; and molecular diagnostics. In this review, we summarize these techniques and identify their merits and pitfalls in the identification of the causative agents of mycetoma and the extent of the disease. We also emphasize the fact that there is no ideal diagnostic tool available to identify the causative agents and that future research should focus on the development of new and reliable diagnostic tools. PMID:24992636

  11. Artifacts and pitfalls in MR imaging of the pelvis.

    PubMed

    Zand, Khashayar Rafat; Reinhold, Caroline; Haider, Masoom A; Nakai, Asako; Rohoman, Laurian; Maheshwari, Sharad

    2007-09-01

    Artifacts are intimately intertwined with MRI. For the practicing radiologist, effective supervision, troubleshooting, and interpretation of diagnostic MR studies require a solid knowledge of the pertinent artifacts. This article seeks to familiarize the reader with commonly encountered artifacts and pitfalls in pelvic imaging, the mechanism behind their generation, and methods of minimizing their negative impact or maximizing their diagnostic yield. It also serves as an exciting tool to learn many aspects of basic and advanced MR physics. Artifacts are categorized into patient- and sequence-related artifacts. Various manifestations of motion and vascular artifacts, susceptibility, altered tissue contrast, blurring, chemical shift artifact, volume averaging, and gadolinium (Gd) pseudolayering are explained, along with their proposed remedies.

  12. Visual, Physiological, and Aesthetic Factors and Pitfalls in Asian Blepharoplasty

    PubMed Central

    Chen, William Pai-Dei

    2016-01-01

    Double eyelid surgery to create an upper-lid crease in Asian patients is one of the more popular aesthetic surgeries among people of Asian descent. Much has been written about the myriad methods, but little has been written about the underlying factors that predispose a patient to complications and suboptimal results. This article touches on some of the possible errors in placement of crease height in upper blepharoplasty and the pitfalls that can be associated with permanent placement of nondissolvable sutures that encircle the complex layers of the upper eyelid, as well as the ideal eyelid crease wound closure and its biodynamics. One should consider these factors in any form of upper eyelid procedure, as they are not merely applicable to upper blepharoplasty. PMID:26673576

  13. Multi-criteria decision analysis: Limitations, pitfalls, and practical difficulties

    SciTech Connect

    Kujawski, Edouard

    2003-02-01

    The 2002 Winter Olympics women's figure skating competition is used as a case study to illustrate some of the limitations, pitfalls, and practical difficulties of Multi-Criteria Decision Analysis (MCDA). The paper compares several widely used models for synthesizing the multiple attributes into a single aggregate value. The various MCDA models can provide conflicting rankings of the alternatives for a common set of information even under states of certainty. Analysts involved in MCDA need to deal with the following challenging tasks: (1) selecting an appropriate analysis method, and (2) properly interpreting the results. An additional trap is the availability of software tools that implement specific MCDA models that can beguile the user with quantitative scores. These conclusions are independent of the decision domain and they should help foster better MCDA practices in many fields including systems engineering trade studies.

  14. Ecoinformatics (Big Data) for Agricultural Entomology: Pitfalls, Progress, and Promise.

    PubMed

    Rosenheim, Jay A; Gratton, Claudio

    2017-01-31

    Ecoinformatics, as defined in this review, is the use of preexisting data sets to address questions in ecology. We provide the first review of ecoinformatics methods in agricultural entomology. Ecoinformatics methods have been used to address the full range of questions studied by agricultural entomologists, enabled by the special opportunities associated with data sets, nearly all of which have been observational, that are larger and more diverse and that embrace larger spatial and temporal scales than most experimental studies do. We argue that ecoinformatics research methods and traditional, experimental research methods have strengths and weaknesses that are largely complementary. We address the important interpretational challenges associated with observational data sets, highlight common pitfalls, and propose some best practices for researchers using these methods. Ecoinformatics methods hold great promise as a vehicle for capitalizing on the explosion of data emanating from farmers, researchers, and the public, as novel sampling and sensing techniques are developed and digital data sharing becomes more widespread.

  15. The Tips and Pitfalls of Meniscus Allograft Transplantation

    PubMed Central

    Lee, Sung Rak; Nam, Sang Wook

    2012-01-01

    When faced with an irrepairable meniscus or a patient who has had a total or subtotal meniscectomy, meniscus allograft transplantation (MAT) is the preferred modality to restore biomechanical function of the meniscus. The indications for meniscus allograft transplantation are yet to be established. However, currently, MAT has previously been indicated for symptomatic patients who have mild or early osteoarthritis, are younger than 50 years of age, and present with an Outerbridge grade II or lower. The short- to intermediate-term results confirmed noteworthy clinical improvements and consistent objective findings. On the other hand, the successful outcome would be reduced by various complications. Therefore, long-term observation required to evaluate the longevity of these results. The purpose of this article is to review the current research of concerns on the results of MAT, and to describe the technical tips and pitfalls so as to successful clinical results. PMID:22977790

  16. The neuroaesthetics of prose fiction: pitfalls, parameters and prospects.

    PubMed

    Burke, Michael

    2015-01-01

    There is a paucity of neuroaesthetic studies on prose fiction. This is in contrast to the very many impressive studies that have been conducted in recent times on the neuroaesthetics of sister arts such as painting, music and dance. Why might this be the case, what are its causes and, of greatest importance, how can it best be resolved? In this article, the pitfalls, parameters and prospects of a neuroaesthetics of prose fiction will be explored. The article itself is part critical review, part methodological proposal and part opinion paper. Its aim is simple: to stimulate, excite and energize thinking in the discipline as to how prose fiction might be fully integrated in the canon of neuroaesthetics and to point to opportunities where neuroimaging studies on literary discourse processing might be conducted in collaborative work bringing humanists and scientists together.

  17. Scrum and Global Delivery: Pitfalls and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Sadun, Cristiano

    Two trends are becoming widespread in software development work—agile development processes and global delivery, both promising sizable benefits in productivity, capacity and so on. Combining the two is a highly attractive possibility, even more so in fast-paced and constrained commercial software engineering projects. However, a degree of conflict exists between the assumptions underlying the two ideas, leading to pitfalls and challenges in agile/distributed projects which are new, both with respect to traditional development and agile or distributed efforts adopted separately. Succeeding in commercial agile/distributed projects implies recognizing these new challenges, proactively planning for them, and actively put in place solutions and methods to overcome them. This chapter illustrates some of the typical challenges that were met during real-world commercial projects, and how they were solved.

  18. Imaging in axial spondyloarthritis: diagnostic problems and pitfalls.

    PubMed

    Baraliakos, Xenofon; Hermann, Kay-Geert A; Braun, Jürgen

    2012-08-01

    Magnetic Structural changes in axial Spondyloarthritis (axSpA) are best identified by conventional radiographs, while magnetic resonance imaging (MRI) is considered the gold standard for assessment of inflammatory changes. Imaging of the axial skeleton is crucial for the diagnosis but also for classification to non-radiographic axSpA according to the 2009 ASAS classification criteria. Despite the existing definitions for a positive MRI for the sacroiliac joints and the spine, these predefined lesions can also be seen in other conditions, representing pitfalls and false-positive conclusions in patients with similar clinical symptoms who do not have SpA. Diagnosis of SpA should result from the combination of clinical, laboratory and imaging findings.

  19. The Head-fixed Behaving Rat—Procedures and Pitfalls

    PubMed Central

    Schwarz, Cornelius; Hentschke, Harald; Butovas, Sergejus; Haiss, Florent; Stüttgen, Maik C; Gerdjikov, Todor V; Bergner, Caroline G; Waiblinger, Christian

    2010-01-01

    This paper describes experimental techniques with head-fixed, operantly conditioned rodents that allow the control of stimulus presentation and tracking of motor output at hitherto unprecedented levels of spatio-temporal precision. Experimental procedures for the surgery and behavioral training are presented. We place particular emphasis on potential pitfalls using these procedures in order to assist investigators who intend to engage in this type of experiment. We argue that head-fixed rodent models, by allowing the combination of methodologies from molecular manipulations, intracellular electrophysiology, and imaging to behavioral measurements, will be instrumental in combining insights into the functional neuronal organization at different levels of observation. Provided viable behavioral methods are implemented, model systems based on rodents will be complementary to current primate models—the latter providing highest comparability with the human brain, while the former offer hugely advanced methodologies on the lower levels of organization, for example, genetic alterations, intracellular electrophysiology, and imaging. PMID:20954892

  20. Extrapolation technique pitfalls in asymmetry measurements at colliders

    NASA Astrophysics Data System (ADS)

    Colletti, Katrina; Hong, Ziqing; Toback, David; Wilson, Jonathan S.

    2016-09-01

    Asymmetry measurements are common in collider experiments and can sensitively probe particle properties. Typically, data can only be measured in a finite region covered by the detector, so an extrapolation from the visible asymmetry to the inclusive asymmetry is necessary. Often a constant multiplicative factor is advantageous for the extrapolation and this factor can be readily determined using simulation methods. However, there is a potential, avoidable pitfall involved in the determination of this factor when the asymmetry in the simulated data sample is small. We find that to obtain a reliable estimate of the extrapolation factor, the number of simulated events required rises as the inverse square of the simulated asymmetry; this can mean that an unexpectedly large sample size is required when determining the extrapolation factor.

  1. Diagnostic pitfalls in spine surgery: masqueraders of surgical spine disease.

    PubMed

    Walcott, Brian P; Coumans, Jean-Valery C E; Kahle, Kristopher T

    2011-10-01

    Disorders of the spine are common in clinical medicine, and spine surgery is being performed with increasing frequency in the US. Although many patients with an established diagnosis of a true surgically treatable lesion are referred to a neurosurgeon, the evaluation of patients with spinal disorders can be complex and fraught with diagnostic pitfalls. While "common conditions are common," astute clinical acumen and vigilance are necessary to identify lesions that masquerade as surgically treatable spine disease that can lead to erroneous diagnosis and treatment. In this review, the authors discuss musculoskeletal, peripheral nerve, metabolic, infectious, inflammatory, and vascular conditions that mimic the syndromes produced by surgical lesions. It is possible that nonsurgical and surgical conditions coexist at times, complicating treatment plans and natural histories. Awareness of these diagnoses can help reduce diagnostic error, thereby avoiding the morbidity and expense associated with an unnecessary operation.

  2. The neuroaesthetics of prose fiction: pitfalls, parameters and prospects

    PubMed Central

    Burke, Michael

    2015-01-01

    There is a paucity of neuroaesthetic studies on prose fiction. This is in contrast to the very many impressive studies that have been conducted in recent times on the neuroaesthetics of sister arts such as painting, music and dance. Why might this be the case, what are its causes and, of greatest importance, how can it best be resolved? In this article, the pitfalls, parameters and prospects of a neuroaesthetics of prose fiction will be explored. The article itself is part critical review, part methodological proposal and part opinion paper. Its aim is simple: to stimulate, excite and energize thinking in the discipline as to how prose fiction might be fully integrated in the canon of neuroaesthetics and to point to opportunities where neuroimaging studies on literary discourse processing might be conducted in collaborative work bringing humanists and scientists together. PMID:26283953

  3. The role of thermodynamics in disc fragmentation

    NASA Astrophysics Data System (ADS)

    Stamatellos, Dimitris; Whitworth, Anthony P.

    2009-12-01

    Thermodynamics play an important role in determining the way a protostellar disc fragments to form planets, brown dwarfs and low-mass stars. We explore the effect that different treatments of radiative transfer have in simulations of fragmenting discs. Three prescriptions for the radiative transfer are used: (i) the diffusion approximation of Stamatellos et al.; (ii) the barotropic equation of state (EOS) of Goodwin et al. and (iii) the barotropic EOS of Bate et al. The barotropic approximations capture the general evolution of the density and temperature at the centre of each proto-fragment but (i) they do not make any adjustments for particular circumstances of a proto-fragment forming in the disc and (ii) they do not take into account thermal inertia effects that are important for fast-forming proto-fragments in the outer disc region. As a result, the number of fragments formed in the disc and their properties are different, when a barotropic EOS is used. This is important not only for disc studies but also for simulations of collapsing turbulent clouds, as in many cases in such simulations stars form with discs that subsequently fragment. We also examine the difference in the way proto-fragments condense out in the disc at different distances from the central star using the diffusion approximation and following the collapse of each proto-fragment until the formation of the second core (ρ ~= 10-3gcm-3). We find that proto-fragments forming closer to the central star tend to form earlier and evolve faster from the first to the second core than proto-fragments forming in the outer disc region. The former have a large pool of material in the inner disc region that they can accrete from and grow in mass. The latter accrete more slowly and they are hotter because they generally form in a quick abrupt event.

  4. Designing sensory-substitution devices: Principles, pitfalls and potential1

    PubMed Central

    Kristjánsson, Árni; Moldoveanu, Alin; Jóhannesson, Ómar I.; Balan, Oana; Spagnol, Simone; Valgeirsdóttir, Vigdís Vala; Unnthorsson, Rúnar

    2016-01-01

    An exciting possibility for compensating for loss of sensory function is to augment deficient senses by conveying missing information through an intact sense. Here we present an overview of techniques that have been developed for sensory substitution (SS) for the blind, through both touch and audition, with special emphasis on the importance of training for the use of such devices, while highlighting potential pitfalls in their design. One example of a pitfall is how conveying extra information about the environment risks sensory overload. Related to this, the limits of attentional capacity make it important to focus on key information and avoid redundancies. Also, differences in processing characteristics and bandwidth between sensory systems severely constrain the information that can be conveyed. Furthermore, perception is a continuous process and does not involve a snapshot of the environment. Design of sensory substitution devices therefore requires assessment of the nature of spatiotemporal continuity for the different senses. Basic psychophysical and neuroscientific research into representations of the environment and the most effective ways of conveying information should lead to better design of sensory substitution systems. Sensory substitution devices should emphasize usability, and should not interfere with other inter- or intramodal perceptual function. Devices should be task-focused since in many cases it may be impractical to convey too many aspects of the environment. Evidence for multisensory integration in the representation of the environment suggests that researchers should not limit themselves to a single modality in their design. Finally, we recommend active training on devices, especially since it allows for externalization, where proximal sensory stimulation is attributed to a distinct exterior object. PMID:27567755

  5. Big data in sleep medicine: prospects and pitfalls in phenotyping

    PubMed Central

    Bianchi, Matt T; Russo, Kathryn; Gabbidon, Harriett; Smith, Tiaundra; Goparaju, Balaji; Westover, M Brandon

    2017-01-01

    Clinical polysomnography (PSG) databases are a rich resource in the era of “big data” analytics. We explore the uses and potential pitfalls of clinical data mining of PSG using statistical principles and analysis of clinical data from our sleep center. We performed retrospective analysis of self-reported and objective PSG data from adults who underwent overnight PSG (diagnostic tests, n=1835). Self-reported symptoms overlapped markedly between the two most common categories, insomnia and sleep apnea, with the majority reporting symptoms of both disorders. Standard clinical metrics routinely reported on objective data were analyzed for basic properties (missing values, distributions), pairwise correlations, and descriptive phenotyping. Of 41 continuous variables, including clinical and PSG derived, none passed testing for normality. Objective findings of sleep apnea and periodic limb movements were common, with 51% having an apnea–hypopnea index (AHI) >5 per hour and 25% having a leg movement index >15 per hour. Different visualization methods are shown for common variables to explore population distributions. Phenotyping methods based on clinical databases are discussed for sleep architecture, sleep apnea, and insomnia. Inferential pitfalls are discussed using the current dataset and case examples from the literature. The increasing availability of clinical databases for large-scale analytics holds important promise in sleep medicine, especially as it becomes increasingly important to demonstrate the utility of clinical testing methods in management of sleep disorders. Awareness of the strengths, as well as caution regarding the limitations, will maximize the productive use of big data analytics in sleep medicine. PMID:28243157

  6. Herbal hepatotoxicity: Challenges and pitfalls of causality assessment methods

    PubMed Central

    Teschke, Rolf; Frenzel, Christian; Schulze, Johannes; Eickhoff, Axel

    2013-01-01

    The diagnosis of herbal hepatotoxicity or herb induced liver injury (HILI) represents a particular clinical and regulatory challenge with major pitfalls for the causality evaluation. At the day HILI is suspected in a patient, physicians should start assessing the quality of the used herbal product, optimizing the clinical data for completeness, and applying the Council for International Organizations of Medical Sciences (CIOMS) scale for initial causality assessment. This scale is structured, quantitative, liver specific, and validated for hepatotoxicity cases. Its items provide individual scores, which together yield causality levels of highly probable, probable, possible, unlikely, and excluded. After completion by additional information including raw data, this scale with all items should be reported to regulatory agencies and manufacturers for further evaluation. The CIOMS scale is preferred as tool for assessing causality in hepatotoxicity cases, compared to numerous other causality assessment methods, which are inferior on various grounds. Among these disputed methods are the Maria and Victorino scale, an insufficiently qualified, shortened version of the CIOMS scale, as well as various liver unspecific methods such as the ad hoc causality approach, the Naranjo scale, the World Health Organization (WHO) method, and the Karch and Lasagna method. An expert panel is required for the Drug Induced Liver Injury Network method, the WHO method, and other approaches based on expert opinion, which provide retrospective analyses with a long delay and thereby prevent a timely assessment of the illness in question by the physician. In conclusion, HILI causality assessment is challenging and is best achieved by the liver specific CIOMS scale, avoiding pitfalls commonly observed with other approaches. PMID:23704820

  7. What Is a Hip Replacement?

    MedlinePlus

    ... Replacement PDF Version Size: 123 KB Audio Version Time: 10:01 Size: 9.4 MB November 2014 What Is a Hip Replacement? Fast Facts: An Easy-to-Read Series of Publications for the Public Hip replacement surgery ...

  8. Toxicology of chlorofluorocarbon replacements.

    PubMed

    Dekant, W

    1996-03-01

    Chlorofluorocarbons (CFCs) are stable in the atmosphere and may reach the stratosphere. They are cleaved by UV-radiation in the stratosphere to yield chlorine radicals, which are thought to interfere with the catalytic cycle of ozone formation and destruction and deplete stratospheric ozone concentrations. Due to potential adverse health effects of ozone depletion, chlorofluorocarbon replacements with much lower or absent ozone depleting potential are developed. The toxicology of these compounds that represent chlorofluorohydrocarbons (HCFCs) or fluorohydrocarbons (HFCs) has been intensively studied. All compounds investigated (1, 1-dichloro-1-fluoroethane [HCFC-141b], 1,1,1,2-tetrafluoroethane [HFC-134a], pentafluoroethane [HFC-125], 1-chloro- 1,2,2,2-tetrafluoroethane [HCFC-124], and 1,1-dichloro-2,2,2-trifluoroethane [HCFC-123]) show only a low potential for skin and eye irritation. Chronic adverse effects on the liver (HCFC-123) and the testes (HCFC-141b and HCFC-134a), including tumor formation, were observed in long-term inhalation studies in rodents using very high concentrations of these CFC replacements. All CFC replacements are, to varying extents, biotransformed in the organism, mainly by cytochrome P450-catalyzed oxidation of C-H bonds. The formed acyl halides are hydrolyzed to give excretable carboxylic acids; halogenated aldehydes that are formed may be further oxidized to halogenated carboxylic acids or reduced to halogenated alcohols, which are excretory metabolites in urine from rodents exposed experimentally to CFC replacements. The chronic toxicity of the CFC replacements studied is unlikely to be of relevance for humans exposed during production and application of CFC replacements.

  9. Lumbar herniated disc: spontaneous regression

    PubMed Central

    Yüksel, Kasım Zafer

    2017-01-01

    Background Low back pain is a frequent condition that results in substantial disability and causes admission of patients to neurosurgery clinics. To evaluate and present the therapeutic outcomes in lumbar disc hernia (LDH) patients treated by means of a conservative approach, consisting of bed rest and medical therapy. Methods This retrospective cohort was carried out in the neurosurgery departments of hospitals in Kahramanmaraş city and 23 patients diagnosed with LDH at the levels of L3−L4, L4−L5 or L5−S1 were enrolled. Results The average age was 38.4 ± 8.0 and the chief complaint was low back pain and sciatica radiating to one or both lower extremities. Conservative treatment was administered. Neurological examination findings, durations of treatment and intervals until symptomatic recovery were recorded. Laségue tests and neurosensory examination revealed that mild neurological deficits existed in 16 of our patients. Previously, 5 patients had received physiotherapy and 7 patients had been on medical treatment. The number of patients with LDH at the level of L3−L4, L4−L5, and L5−S1 were 1, 13, and 9, respectively. All patients reported that they had benefit from medical treatment and bed rest, and radiologic improvement was observed simultaneously on MRI scans. The average duration until symptomatic recovery and/or regression of LDH symptoms was 13.6 ± 5.4 months (range: 5−22). Conclusions It should be kept in mind that lumbar disc hernias could regress with medical treatment and rest without surgery, and there should be an awareness that these patients could recover radiologically. This condition must be taken into account during decision making for surgical intervention in LDH patients devoid of indications for emergent surgery. PMID:28119770

  10. Pitfalls in Persuasion: How Do Users Experience Persuasive Techniques in a Web Service?

    NASA Astrophysics Data System (ADS)

    Segerståhl, Katarina; Kotro, Tanja; Väänänen-Vainio-Mattila, Kaisa

    Persuasive technologies are designed by utilizing a variety of interactive techniques that are believed to promote target behaviors. This paper describes a field study in which the aim was to discover possible pitfalls of persuasion, i.e., situations in which persuasive techniques do not function as expected. The study investigated persuasive functionality of a web service targeting weight loss. A qualitative online questionnaire was distributed through the web service and a total of 291 responses were extracted for interpretative analysis. The Persuasive Systems Design model (PSD) was used for supporting systematic analysis of persuasive functionality. Pitfalls were identified through situations that evoked negative user experiences. The primary pitfalls discovered were associated with manual logging of eating and exercise behaviors, appropriateness of suggestions and source credibility issues related to social facilitation. These pitfalls, when recognized, can be addressed in design by applying functional and facilitative persuasive techniques in meaningful combinations.

  11. Spontaneous Regression of Herniated Lumbar Disc with New Disc Protrusion in the Adjacent Level

    PubMed Central

    Gürcan, Serkan

    2016-01-01

    Spontaneous regression of herniated lumbar discs was reported occasionally. The mechanisms proposed for regression of disc herniation are still incomplete. This paper describes and discusses a case of spontaneous regression of herniated lumbar discs with a new disc protrusion in the adjacent level. A 41-year-old man was admitted with radiating pain and numbness in the left lower extremity with a left posterolateral disc extrusion at L5-S1 level. He was admitted to hospital with low back pain due to disc herniation caudally immigrating at L4-5 level three years ago. He refused the surgical intervention that was offered and was treated conservatively at that time. He had no neurological deficit and a history of spontaneous regression of the extruded lumbar disc; so, a conservative therapy, including bed rest, physical therapy, nonsteroidal anti-inflammatory drugs, and analgesics, was advised. In conclusion, herniated lumbar disc fragments may regress spontaneously. Reports are prone to advise conservative treatment for extruded or sequestrated lumbar disc herniations. However, these patients should be followed up closely; new herniation at adjacent/different level may occur. Furthermore, it is important to know which herniated disk should be removed and which should be treated conservatively, because disc herniation may cause serious complications as muscle weakness and cauda equine syndrome. PMID:27429818

  12. The Quiescent Growth Of Galactic Discs

    NASA Astrophysics Data System (ADS)

    Binney, James

    2016-09-01

    We use N-bodies to simulate the growth since redshift 2 of an isolated disc in a live halo. Giant molecular clouds (GMCs), The bar and spiral structure all play key roles in the evolution of the disc. Our GMCs are short-lived and have masses drawn from a mass spectrum. Their number density is related to the SFR. For the expected number densities and likely maximum masses of GMCs, they heat the disc very effectively at early times, and either postpone or cancel bar formation. They generate remarkably exponential vertical profiles. Spiral structure drives a level of radial migration that agrees well with that predicted by models of local chemical evolution. The radial patterns of star formation include different levels of inside-out growth. The radial scale length of the final disc is always greater than any of the scale lengths used for star formation and rather independent of the extent of inside-out growth. The only way to obtain a thick disc nearly as massive as those observed is to include in the initial conditions a massive, extended object that will be compressed into the present thick disc by the gravity of the thin disc.

  13. Stem cells sources for intervertebral disc regeneration

    PubMed Central

    Vadalà, Gianluca; Russo, Fabrizio; Ambrosio, Luca; Loppini, Mattia; Denaro, Vincenzo

    2016-01-01

    Intervertebral disc regeneration field is rapidly growing since disc disorders represent a major health problem in industrialized countries with very few possible treatments. Indeed, current available therapies are symptomatic, and surgical procedures consist in disc removal and spinal fusion, which is not immune to regardable concerns about possible comorbidities, cost-effectiveness, secondary risks and long-lasting outcomes. This review paper aims to share recent advances in stem cell therapy for the treatment of intervertebral disc degeneration. In literature the potential use of different adult stem cells for intervertebral disc regeneration has already been reported. Bone marrow mesenchymal stromal/stem cells, adipose tissue derived stem cells, synovial stem cells, muscle-derived stem cells, olfactory neural stem cells, induced pluripotent stem cells, hematopoietic stem cells, disc stem cells, and embryonic stem cells have been studied for this purpose either in vitro or in vivo. Moreover, several engineered carriers (e.g., hydrogels), characterized by full biocompatibility and prompt biodegradation, have been designed and combined with different stem cell types in order to optimize the local and controlled delivery of cellular substrates in situ. The paper overviews the literature discussing the current status of our knowledge of the different stem cells types used as a cell-based therapy for disc regeneration. PMID:27247704

  14. Musculoskeletal pitfalls and pseudotumours in the pelvis: a pictorial review for body imagers

    PubMed Central

    Ghazizadeh, S; Didier, R; Fung, A; Panicek, D M; Coakley, F V

    2014-01-01

    Many musculoskeletal abnormalities in the pelvis are first seen by body imagers while reviewing pelvic cross-sectional studies, and some of these abnormalities may mimic malignancy or another aggressive process. This article describes nine musculoskeletal pseudotumours and interpretative pitfalls that may be seen on CT, MRI and ultrasound imaging of the pelvis. Awareness of these pitfalls and pseudotumours may help avoid misdiagnosis and prevent inappropriate intervention or management. PMID:25096891

  15. Chemical separation of disc components using RAVE

    NASA Astrophysics Data System (ADS)

    Wojno, Jennifer; Kordopatis, Georges; Steinmetz, Matthias; McMillan, Paul; Matijevič, Gal; Binney, James; Wyse, Rosemary F. G.; Boeche, Corrado; Just, Andreas; Grebel, Eva K.; Siebert, Arnaud; Bienaymé, Olivier; Gibson, Brad K.; Zwitter, Tomaž; Bland-Hawthorn, Joss; Navarro, Julio F.; Parker, Quentin A.; Reid, Warren; Seabroke, George; Watson, Fred

    2016-10-01

    We present evidence from the RAdial Velocity Experiment (RAVE) survey of chemically separated, kinematically distinct disc components in the solar neighbourhood. We apply probabilistic chemical selection criteria to separate our sample into α-low (`thin disc') and α-high (`thick disc') sequences. Using newly derived distances, which will be utilized in the upcoming RAVE DR5, we explore the kinematic trends as a function of metallicity for each of the disc components. For our α-low disc, we find a negative trend in the mean rotational velocity (Vφ) as a function of iron abundance ([Fe/H]). We measure a positive gradient ∂Vφ/∂[Fe/H] for the α-high disc, consistent with results from high-resolution surveys. We also find differences between the α-low and α-high discs in all three components of velocity dispersion. We discuss the implications of an α-low, metal-rich population originating from the inner Galaxy, where the orbits of these stars have been significantly altered by radial mixing mechanisms in order to bring them into the solar neighbourhood. The probabilistic separation we propose can be extended to other data sets for which the accuracy in [α/Fe] is not sufficient to disentangle the chemical disc components a priori. For such data sets which will also have significant overlap with Gaia DR1, we can therefore make full use of the improved parallax and proper motion data as it becomes available to investigate kinematic trends in these chemical disc components.

  16. Hexachloroethane Obscurant Replacement

    DTIC Science & Technology

    2012-01-01

    suggest that neither the alkali metal hydroxides nor chlorides are extremely toxic (11). Oral rat LD50 values are indeed lower for hydroxide salts...analyze for toxicity of combustion gases and particulates. Compositions containing boron potassium nitrate igniter blended with halide salts...variants were identified which should have improved performance. 15. SUBJECT TERMS Non- toxic obscurant, hexachloroethane smoke replacement 16

  17. Python import replacement

    SciTech Connect

    2011-10-01

    SmartImport.py is a Python source-code file that implements a replacement for the standard Python module importer. The code is derived from knee.py, a file in the standard Python diestribution , and adds functionality to improve the performance of Python module imports in massively parallel contexts.

  18. Prioritizing equipment for replacement.

    PubMed

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  19. Window Replacement Tips.

    ERIC Educational Resources Information Center

    Wiens, Janet

    2001-01-01

    Explores ways to replace facility windows more easily and efficiently by evaluating long-term needs and window options. Recommends obtaining references from window manufacturer and installer, scheduling the work during times the facility is unoccupied, and ensuring that historic and life-safety issues be considered. (GR)

  20. Optical Disc Utilized As A Data Storage System For Reconnaissance

    NASA Astrophysics Data System (ADS)

    Herzog, Donald G.

    1984-01-01

    Electra-optic and Radar sensing reconnaissance systems have many advantages including remote transmission and image data processing that conventional film camera systems do not have. However, data storage and retrieval that was naturally and easily accomplished with film must now be accommodated by other techniques. The optical disc data storage and retrieval systems offer significant advantage towards fulfilling this need. This paper will provide an overview description of the technology, some of the fundamental alternatives of configuration approach, and some examples of where it may be considered in the reconnaissance system. Silver halide film has been and still is the work horse of the image based reconnaissance field. It will not be replaced in the near future either, but rather a gradual transition to total electronic systems is expected. It is not the intent of this paper to debase film, because in fact it has its advantages. We have learned to optimize its advantages and minimize its disadvantages. However optical disc systems have a definite role to play in the reconnaissance field.

  1. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Interarticular disc prosthesis (interpositional... disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis... Food and Drug Administration on or before March 30, 1999, for any interarticular disc...

  2. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Interarticular disc prosthesis (interpositional... disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis... Food and Drug Administration on or before March 30, 1999, for any interarticular disc...

  3. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Interarticular disc prosthesis (interpositional... disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis... Food and Drug Administration on or before March 30, 1999, for any interarticular disc...

  4. Archival-grade optical disc design and international standards

    NASA Astrophysics Data System (ADS)

    Fujii, Toru; Kojyo, Shinichi; Endo, Akihisa; Kodaira, Takuo; Mori, Fumi; Shimizu, Atsuo

    2015-09-01

    Optical discs currently on the market exhibit large variations in life span among discs, making them unsuitable for certain business applications. To assess and potentially mitigate this problem, we performed accelerated degradation testing under standard ISO conditions, determined the probable disc failure mechanisms, and identified the essential criteria necessary for a stable disc composition. With these criteria as necessary conditions, we analyzed the physical and chemical changes that occur in the disc components, on the basis of which we determined technological measures to reduce these degradation processes. By applying these measures to disc fabrication, we were able to develop highly stable optical discs.

  5. Treatment of lumbar disc herniation by percutaneous laser disc decompression (PLDD) and modified PLDD

    NASA Astrophysics Data System (ADS)

    Chi, Xiao fei; Li, Hong zhi; Wu, Ru zhou; Sui, Yun xian

    2005-07-01

    Objective: To study the micro-invasive operative method and to compare the effect of treatment of PLDD and modified PLDD for Lumbar Disc Herniation. Method: Vaporized part of the nucleus pulposus in single or multiple point after acupuncture into lumbar disc, to reach the purpose of the decompression of the lumbar disc. Result: Among the 19 cases of the regular PLDD group, the excellent and good rate was 63.2%, and among the 40 cases of the modified PLDD group, the excellent and good rate was 82.5%. Conclusion: The modified PLDD has good effect on the treatment for lumbar disc herniation.

  6. Genetics Home Reference: intervertebral disc disease

    MedlinePlus

    ... link) National Institute of Neurological Disorders and Stroke: Low Back Pain Fact Sheet Educational Resources (8 links) American Association ... MalaCards: intervertebral disc disease Merck Manual Consumer Version: Low Back Pain Merck Manual Consumer Version: Neck Pain The Children's ...

  7. Dynamical modelling of galactic disc outskirts

    NASA Astrophysics Data System (ADS)

    Athanassoula, E.

    2017-03-01

    I review briefly some dynamical models of structures in the outer parts of disc galaxies, including models of polar rings, tidal tails and bridges. I then discuss the density distribution in the outer parts of discs. For this, I compare observations to results of a model in which the disc galaxy is in fact the remnant of a major merger, and find good agreement. This comparison includes radial profiles of the projected surface density and of stellar age, as well as time evolution of the break radius and of the inner and outer disc scale lengths. I also compare the radial projected surface density profiles of dynamically motivated mono-age populations and find that, compared to older populations, younger ones have flatter density profiles in the inner region and steeper in the outer one. The break radius, however, does not vary with stellar age, again in good agreement with observations.

  8. [Disc electrophoresis of collagen protein (author's transl)].

    PubMed

    Reitmayr, P; Verzár, F

    1975-01-01

    The composition of proteins extracted from tendon collagen is investigated by disc electrophoresis. No qualitative differences can be demonstrated between young and old collagen. The action of formaldehyde and methionine on the tendons has no effect on the electrophoretic picture.

  9. ARRANGEMENT FOR REPLACING FILTERS

    DOEpatents

    Blomgren, R.A.; Bohlin, N.J.C.

    1957-08-27

    An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.

  10. NARC Rayon Replacement Program

    NASA Technical Reports Server (NTRS)

    Wilson, Kenneth P.; McCool, Alex (Technical Monitor)

    2002-01-01

    This viewgraph presentation provides information on the search for a replacement product for the aerospace grade rayon formerly used in the reusable solid rocket motor (RSRM). The rayon used in RSRMs is no longer produced by the North American Rayon Corporation (NARC), though NASA has stockpiled rayon to be used until a suitable replacement is found to be used in the RSRM nozzle carbon cloth phenolic (CCP). The primary considerations are performance, process ability, variability, long term availability, and cost. The preference will be given to commercial off-the-shelf products as opposed to those which are custom made. The candidate materials have been tested in previous phases of this selection process, and Enka Textile Rayon has emerged as a possible fabric, though its availability is still in question.

  11. Celotex (Registered) Replacement Study

    SciTech Connect

    Couture, S; Hafner, R

    2002-10-01

    The AL-R8 is the pit storage container in most widespread use at Pantex. The AL-R8 container family consists of standard 20-in.-diameter steel drums, 30 to 60 in. in height, with insulation inserts made of Celotex{reg_sign}--a fiberboard product made from processed sugar cane. Celotex is an acceptable material for inserts in many radioactive material shipping and storage containers. It is a good shock mitigator/insulator, does a fair job in fire protection (when oxygen is excluded), shielding, and criticality, and is inexpensive and easily available. However, the fiberboard absorbs water in humid environments which, when combined with chemical residues in the fiberboard, forms corrosive compounds that can shorten the life of the container and affect container contents. To protect the contents from this potentially damaging environment, the AL-R8 SI was developed to isolate the contents within a sealed stainless steel vessel inside the AL-R8. Although the SI protected the contents, corrosion studies indicated the SI lid bolts might corrode over time and surveillance showed that areas of the outer drum were still subject to corrosion. To address this potential problem, DOE/Albuquerque sponsored bolt and Celotex replacement studies. The bolt replacement study was assigned to Mason and Hanger's Pantex Facility and this Celotex Replacement Study to Lawrence Livermore National Laboratory. The Celotex Replacement Study evaluated options for replacing Celotex with a material that is chemically compatible with the AL-R8 SI container. The evaluation was limited to materials either used previously in nuclear materials shipping and storage containers or materials with known properties in a low-radiation environment. This limitation was set to ensure that the long-term aging effect on the new material is known a priori. Initial material evaluations narrowed the material choices to foam and cork. Although cork performed better than foam in some tests, cork was considered a less

  12. Investigation of cryogenic rupture disc design

    NASA Technical Reports Server (NTRS)

    Keough, J. B.; Oldland, A. H.

    1973-01-01

    Rupture disc designs of both the active (command actuated) and passive (pressure ruptured) types were evaluated for performance characteristics at cryogenic temperatures and for capability to operate in a variety of cryogens, including gaseous and liquid fluorine. The test results, coupled with information from literature and industry searches, were used to establish a statement of design criteria and recommended practices for application of rupture discs to cryogenic rocket propellant feed and vent systems.

  13. Disc valve for sampling erosive process streams

    DOEpatents

    Mrochek, John E.; Dinsmore, Stanley R.; Chandler, Edward W.

    1986-01-01

    A four-port disc valve for sampling erosive, high temperature process streams. A rotatable disc defining opposed first and second sampling cavities rotates between fired faceplates defining flow passageways positioned to be alternatively in axial alignment with the first and second cavities. Silicon carbide inserts and liners composed of .alpha. silicon carbide are provided in the faceplates and in the sampling cavities to limit erosion while providing lubricity for a smooth and precise operation when used under harsh process conditions.

  14. Hospital Ship Replacement

    DTIC Science & Technology

    2011-08-01

    designed to operate primarily when anchored to reduce the effects of roll. Quantum markets two separate zero speed active roll fin models for small ...ships. Feasibility of scaling fins to the size of the hospital ship requires validation. 3.12 Lifeboats and Liferafts The safety appliances designated ...for Innovation in Ship Design Technical Report Hospital Ship Replacement By Hannah Allison, Christopher Mehrvarzi, Rebecca Piks, Beau Lovdahl

  15. Renal Replacement Therapy

    PubMed Central

    Ricci, Zaccaria; Romagnoli, Stefano; Ronco, Claudio

    2016-01-01

    During the last few years, due to medical and surgical evolution, patients with increasingly severe diseases causing multiorgan dysfunction are frequently admitted to intensive care units. Therapeutic options, when organ failure occurs, are frequently nonspecific and mostly directed towards supporting vital function. In these scenarios, the kidneys are almost always involved and, therefore, renal replacement therapies have become a common routine practice in critically ill patients with acute kidney injury. Recent technological improvement has led to the production of safe, versatile and efficient dialysis machines. In addition, emerging evidence may allow better individualization of treatment with tailored prescription depending on the patients’ clinical picture (e.g. sepsis, fluid overload, pediatric). The aim of the present review is to give a general overview of current practice in renal replacement therapies for critically ill patients. The main clinical aspects, including dose prescription, modality of dialysis delivery, anticoagulation strategies and timing will be addressed. In addition, some technical issues on physical principles governing blood purification, filters characteristics, and vascular access, will be covered. Finally, a section on current standard nomenclature of renal replacement therapy is devoted to clarify the “Tower of Babel” of critical care nephrology. PMID:26918174

  16. Ulnar head replacement.

    PubMed

    Herbert, Timothy J; van Schoonhoven, Joerg

    2007-03-01

    Recent years have seen an increasing awareness of the anatomical and biomechanical significance of the distal radioulnar joint (DRUJ). With this has come a more critical approach to surgical management of DRUJ disorders and a realization that all forms of "excision arthroplasty" can only restore forearm rotation at the expense of forearm stability. This, in turn, has led to renewed interest in prosthetic replacement of the ulnar head, a procedure that had previously fallen into disrepute because of material failures with early implants, in particular, the Swanson silicone ulnar head replacement. In response to these early failures, a new prosthesis was developed in the early 1990s, using materials designed to withstand the loads across the DRUJ associated with normal functional use of the upper limb. Released onto the market in 1995 (Herbert ulnar head prosthesis), clinical experience during the last 10 years has shown that this prosthesis is able to restore forearm function after ulnar head excision and that the materials (ceramic head and noncemented titanium stem), even with normal use of the limb, are showing no signs of failure in the medium to long term. As experience with the use of an ulnar head prosthesis grows, so does its acceptance as a viable and attractive alternative to more traditional operations, such as the Darrach and Sauve-Kapandji procedures. This article discusses the current indications and contraindications for ulnar head replacement and details the surgical procedure, rehabilitation, and likely outcomes.

  17. Validation of Sodium MRI of Intervertebral Disc

    PubMed Central

    Wang, Chenyang; McArdle, Erin; Fenty, Matthew; Witschey, Walter; Elliott, Mark; Sochor, Matthew; Reddy, Ravinder; Borthakur, Arijitt

    2009-01-01

    Study Design This study demonstrated the diagnostic potential of sodium MRI for non-invasive quantification of PG in the intervertebral discs. Objective To determine the existence of a linear correlation between intervertebral disc [Na] measured from sodium MRI and [PG] measurement from DMMB assay. Summary of Background Data Previous studies have shown the possibility of quantifying [Na] in vivo using sodium MRI, however none has shown a direct linear correlation between [Na] measured from sodium MRI and [PG]. Methods 3D sodium MRI images of bovine discs were acquired and converted into [Na] maps. Samples were systematically removed from the discs for DMMB assay. The removal locations were photographically recorded and applied to the [Na] maps to extract the [Na] measurements for comparison. In vivo sodium MRI scans were also carried out on a pair of symptomatic and asymptomatic subjects. Results The linear regression fit of [Na] versus [PG] data yielded a significant linear correlation coefficient of 0.71. The in vivo sodium MRI image of the symptomatic subject showed significant [Na] decrease when compared to that of the asymptomatic subject. Conclusion Sodium MRI's specificity for PG in the intervertebral discs makes it a promising diagnostic tool for the earlier phase of disc degeneration. PMID:20147881

  18. Polyurethane scaffold with in situ swelling capacity for nucleus pulposus replacement.

    PubMed

    Li, Zhen; Lang, Gernot; Chen, Xu; Sacks, Hagit; Mantzur, Carmit; Tropp, Udi; Mader, Kerstin T; Smallwood, Thomas C; Sammon, Chris; Richards, R Geoff; Alini, Mauro; Grad, Sibylle

    2016-04-01

    Nucleus pulposus (NP) replacement offers a minimally invasive alternative to spinal fusion or total disc replacement for the treatment of intervertebral disc (IVD) degeneration. This study aimed to develop a cytocompatible NP replacement material, which is feasible for non-invasive delivery and tunable design, and allows immediate mechanical restoration of the IVD. A bi-phasic polyurethane scaffold was fabricated consisting of a core material with rapid swelling property and a flexible electrospun envelope. The scaffold was assessed in a bovine whole IVD organ culture model under dynamic load for 14 days. Nucleotomy was achieved by incision through the endplate without damaging the annulus fibrosus. After implantation of the scaffold and in situ swelling, the dynamic compressive stiffness and disc height were restored immediately. The scaffold also showed favorable cytocompatibility for native disc cells. Implantation of the scaffold in a partially nucleotomized IVD down-regulated catabolic gene expression, increased proteoglycan and type II collagen intensity and decreased type I collagen intensity in remaining NP tissue, indicating potential to retard degeneration and preserve the IVD cell phenotype. The scaffold can be delivered in a minimally invasive manner, and the geometry of the scaffold post-hydration is tunable by adjusting the core material, which allows individualized design.

  19. Radio Monitoring of Protoplanetary Discs

    NASA Astrophysics Data System (ADS)

    Ubach, C.; Maddison, S. T.; Wright, C. M.; Wilner, D. J.; Lommen, D. J. P.; Koribalski, B.

    2017-01-01

    Protoplanetary disc systems observed at radio wavelengths often show excess emission above that expected from a simple extrapolation of thermal dust emission observed at short millimetre wavelengths. Monitoring the emission at radio wavelengths can be used to help disentangle the physical mechanisms responsible for this excess, including free-free emission from a wind or jet, and chromospheric emission associated with stellar activity. We present new results from a radio monitoring survey conducted with Australia Telescope Compact Array over the course of several years with observation intervals spanning days, months and years, where the flux variability of 11 T Tauri stars in the Chamaeleon and Lupus star forming regions was measured at 7 and 15 mm and 3 and 6 cm. Results show that for most sources are variable to some degree at 7 mm, indicating the presence of emission mechanisms other than thermal dust in some sources. Additionally, evidence of grain growth to cm-sized pebbles was found for some sources that also have signs of variable flux at 7 mm. We conclude that multiple processes contributing to the emission are common in T Tauri stars at 7 mm and beyond, and that a detection at a single epoch at radio wavelengths should not be used to determine all processes contributing to the emission.

  20. Circumplanetary disc or circumplanetary envelope?

    NASA Astrophysics Data System (ADS)

    Szulágyi, J.; Masset, F.; Lega, E.; Crida, A.; Morbidelli, A.; Guillot, T.

    2016-08-01

    We present three-dimensional simulations with nested meshes of the dynamics of the gas around a Jupiter mass planet with the JUPITER and FARGOCA codes. We implemented a radiative transfer module into the JUPITER code to account for realistic heating and cooling of the gas. We focus on the circumplanetary gas flow, determining its characteristics at very high resolution (80 per cent of Jupiter's diameter). In our nominal simulation where the temperature evolves freely by the radiative module and reaches 13000 K at the planet, a circumplanetary envelope was formed filling the entire Roche lobe. Because of our equation of state is simplified and probably overestimates the temperature, we also performed simulations with limited maximal temperatures in the planet region (1000, 1500, and 2000 K). In these fixed temperature cases circumplanetary discs (CPDs) were formed. This suggests that the capability to form a CPD is not simply linked to the mass of the planet and its ability to open a gap. Instead, the gas temperature at the planet's location, which depends on its accretion history, plays also fundamental role. The CPDs in the simulations are hot and cooling very slowly, they have very steep temperature and density profiles, and are strongly sub-Keplerian. Moreover, the CPDs are fed by a strong vertical influx, which shocks on the CPD surfaces creating a hot and luminous shock-front. In contrast, the pressure supported circumplanetary envelope is characterized by internal convection and almost stalled rotation.

  1. Pitfalls and Limitations of Radionuclide Planar and Hybrid Bone Imaging.

    PubMed

    Agrawal, Kanhaiyalal; Marafi, Fahad; Gnanasegaran, Gopinath; Van der Wall, Hans; Fogelman, Ignac

    2015-09-01

    The radionuclide (99m)Tc-MDP bone scan is one of the most commonly performed nuclear medicine studies and helps in the diagnosis of different pathologies relating to the musculoskeletal system. With its increasing utility in clinical practice, it becomes more important to be aware of various limitations of this imaging modality to avoid false interpretation. It is necessary to be able to recognize various technical, radiopharmaceutical, and patient-related artifacts that can occur while carrying out a bone scan. Furthermore, several normal variations of tracer uptake may mimic pathology and should be interpreted cautiously. There is an important limitation of a bone scan in metastatic disease evaluation as the inherent mechanism of tracer uptake is not specific for tumor but primarily relies on an osteoblastic response. Thus, it is crucial to keep in mind uptake in benign lesions, which can resemble malignant pathologies. The utility of a planar bone scan in benign orthopedic diseases, especially at sites with complex anatomy, is limited owing to lack of precise anatomical information. SPECT/CT has been significantly helpful in these cases. With wider use of PET/CT and reintroduction of the (18)F-fluoride bone scan, increasing knowledge of potential pitfalls on an (18)F-fluoride bone scan and (18)F-FDG-PET/CT will help in improving the accuracy of clinical reports.

  2. Massively Multiplayer Online Games as Living Laboratories: Opportunities and Pitfalls

    NASA Astrophysics Data System (ADS)

    Ducheneaut, Nicolas

    The digital nature of online games makes them particularly amenable to large-scale, automated data collection and analysis; so researchers have begun to use them as living laboratories to test or refine the existing theories of human behavior. On the basis of several years of intensive data collection in several massively multiplayer online games, this chapter addresses three problems concerning validity and generalizability that must be taken into account. First, each game has a set of laws that steer player behavior, thereby introducing confounding factors that have to be taken into account by the researcher. Second, games attract skewed samples of players, and players may adopt transformed personalities inside the game world, which puts into question the validity of extending findings from observations in the digital realm into the physical one. Third, the lack of a clear boundary defining the "game space," illustrated by the many websites and forums for popular games, raises the question of whether online games themselves capture the totality of the user's experience. The problematic mapping between "real-world" behaviors and those in online games presents research opportunities as well as pitfalls that need to be avoided.

  3. Genetics of Type 2 Diabetes—Pitfalls and Possibilities

    PubMed Central

    Prasad, Rashmi B.; Groop, Leif

    2015-01-01

    Type 2 diabetes (T2D) is a complex disease that is caused by a complex interplay between genetic, epigenetic and environmental factors. While the major environmental factors, diet and activity level, are well known, identification of the genetic factors has been a challenge. However, recent years have seen an explosion of genetic variants in risk and protection of T2D due to the technical development that has allowed genome-wide association studies and next-generation sequencing. Today, more than 120 variants have been convincingly replicated for association with T2D and many more with diabetes-related traits. Still, these variants only explain a small proportion of the total heritability of T2D. In this review, we address the possibilities to elucidate the genetic landscape of T2D as well as discuss pitfalls with current strategies to identify the elusive unknown heritability including the possibility that our definition of diabetes and its subgroups is imprecise and thereby makes the identification of genetic causes difficult. PMID:25774817

  4. Nonlinear Time Series Analysis in Earth Sciences - Potentials and Pitfalls

    NASA Astrophysics Data System (ADS)

    Kurths, Jürgen; Donges, Jonathan F.; Donner, Reik V.; Marwan, Norbert; Zou, Yong

    2010-05-01

    The application of methods of nonlinear time series analysis has a rich tradition in Earth sciences and has enabled substantially new insights into various complex processes there. However, some approaches and findings have been controversially discussed over the last decades. One reason is that they are often bases on strong restrictions and their violation may lead to pitfalls and misinterpretations. Here, we discuss three general concepts of nonlinear dynamics and statistical physics, synchronization, recurrence and complex networks and explain how to use them for data analysis. We show that the corresponding methods can be applied even to rather short and non-stationary data which are typical in Earth sciences. References Marwan, N., Romano, M., Thiel, M., Kurths, J.: Recurrence plots for the analysis of complex systems, Physics Reports 438, 237-329 (2007) Arenas, A., Diaz-Guilera, A., Kurths, J., Moreno, Y., Zhou, C.: Synchronization in complex networks, Physics Reports 469, 93-153 (2008) Marwan, N., Donges, J.F., Zou, Y., Donner, R. and Kurths, J., Phys. Lett. A 373, 4246 (2009) Donges, J.F., Zou, Y., Marwan, N. and Kurths, J. Europhys. Lett. 87, 48007 (2009) Donner, R., Zou, Y., Donges, J.F., Marwan, N. and Kurths, J., Phys. Rev. E 81, 015101(R) (2010)

  5. Pitfalls and Limitations of Radionuclide Renal Imaging in Adults.

    PubMed

    Keramida, Georgia; James, Jacqueline M; Prescott, Mary C; Peters, Adrien Michael

    2015-09-01

    To understand pitfalls and limitations in adult renography, it is necessary to understand firstly the physiology of the kidney, especially the magnitude and control of renal blood flow, glomerular filtration rate and tubular fluid flow rate, and secondly the pharmacokinetics and renal handling of the three most often used tracers, Tc-99m-mercaptoacetyltriglycine (MAG3), Tc-99m-diethylene triamine pentaacetic acid (DTPA) and Tc-99m-dimercaptosuccinic acid (DMSA). The kidneys may be imaged dynamically with Tc-99m-MAG3 or Tc-99m-DTPA, with or without diuretic challenge, or by static imaging with Tc-99m-DMSA. Protocols are different according to whether the kidney is native or transplanted. Quantitative analysis of dynamic data includes measurement of renal vascularity (important for the transplanted kidney), absolute tracer clearance rates, differential renal function (DRF) and response to diuretic challenge. Static image reveals functional renal parenchymal damage, both focal and global, is useful in the clinical management of obstructive uropathy, renal stone disease and hypertension (under angiotensin converting enzyme inhibition), and is the preferred technique for determining DRF. Diagnosis based on morphological appearances is important in transplant management. Even though nuclear medicine is now in the era of hybrid imaging, renal imaging remains an important subspecialty in nuclear medicine and requires a sound basing in applied physiology, the classical supporting discipline of nuclear medicine.

  6. Satellite Verification Planning: Best Practices and Pitfalls Related to Testing

    NASA Astrophysics Data System (ADS)

    Tosney, William F.; Pavlica, S.

    2004-08-01

    Satellite system verification planning is an intensive system engineering process requiring a highly disciplined and coordinated effort among the system engineers involved in requirements generation and flowdown, and engineers involved in the design, test and evaluation, and overall program planning functions. With the recent resurgence in the space industry of more disciplined acquisition and development practices, this paper discusses critical elements of a disciplined verification planning process, as embodied in a variety of space industry specifications, standards, and best practices, with an emphasis on the test planning function. Included in this paper is a look at the criticality of understanding mission operations in verification planning activities. This includes an emphasis on rigorously assessing the need for operational scenario testing under simulated environmental conditions. With increases in satellite complexity, assessing the role of modeling and simulation early in the verification planning process has become a key part of assuring a successful test plan during development. Best practices aimed at avoiding downstream design, production and operational problems are discussed along with common pitfalls and suggestions for improving the technical rigor in the verification planning process, testing execution, and programmatic policies aimed at improving development schedule realism and ultimately, improving mission success.

  7. [Diagnosis pitfalls and emergencies in children with cancer].

    PubMed

    Orbach, Daniel; Gajdos, Vincent; André, Nicolas

    2014-11-01

    Childhood cancers are rare diseases with about 1700 cases below 15 years of age diagnosed in France each year. Although more than 80% of patients are now surviving more than 5 years, cancer remains the leading cause of fatal diseases between the ages of 1 and 15 years. The difficulty of diagnosis is partly due to their rarity but also the apparent banality of initial common symptoms. In industrialized countries, it is rare that an extension of time before diagnosis is associated with decreased survival; at the opposite, this period may be associated with the need for more extensive treatments leading to a greater risk of sequelae. Such delays also have a negative impact on the trust of the child and family with the medical community that may sound on the quality of essential therapeutic alliance. Learn how to diagnose these diseases, prescribe or repeat further explorations in case of persistent symptoms and suggestive signs and possibly refer these patients to a specialized paediatric oncology team is necessary to avoid excessive delay before diagnosis. In addition, it is also important not to ignore situations where these cancers are discovered in emergency situations: vital distress may require concerted management between intensive care and specialized paediatric oncology teams. Authors propose a focus on potential diagnostic pitfalls and emergencies during the initial management of children with cancer and the consequences of any diagnosis delays.

  8. Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls

    PubMed Central

    Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James

    2013-01-01

    Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972

  9. Pitfalls in the characterization of nanoporous and nanosized materials.

    PubMed

    Weidenthaler, Claudia

    2011-03-01

    With the advent of highly sophisticated analytical tools, numerous physical methods are nowadays available for comprehensive characterization of inorganic matter and, as special cases, of porous and nanosized materials. Intelligent experimental setup and correct evaluation of the experimental data can provide helpful insights into the chemical and physical properties of such materials. However, scanning of literature reports shows that in many cases evaluation and interpretation of experimental data are erroneous. As a result, the description of a new material can be useless or even worse, misleading. Wrong evaluation is even more critical if mechanistic theories are based on such data. Characterization of porous and/or nanosized materials is mainly performed by gas adsorption, X-ray powder diffraction, electron microscopy and surface spectroscopy. For correct interpretation of experimental data one should be aware of certain pitfalls. The present paper summarizes prominent faults and may show how they can be avoided. It is supposed to provide some hand-on knowledge on correct analysis of materials. Addressed are primarily non-experts and researchers being new to the field of characterization of inorganic nanosized or nanoporous materials.

  10. Gene therapy for PIDs: progress, pitfalls and prospects.

    PubMed

    Mukherjee, Sayandip; Thrasher, Adrian J

    2013-08-10

    Substantial progress has been made in the past decade in treating several primary immunodeficiency disorders (PIDs) with gene therapy. Current approaches are based on ex-vivo transfer of therapeutic transgene via viral vectors to patient-derived autologous hematopoietic stem cells (HSCs) followed by transplantation back to the patient with or without conditioning. The overall outcome from all the clinical trials targeting different PIDs has been extremely encouraging but not without caveats. Malignant outcomes from insertional mutagenesis have featured prominently in the adverse events associated with these trials and have warranted intense pre-clinical investigation into defining the tendencies of different viral vectors for genomic integration. Coupled with issues pertaining to transgene expression, the therapeutic landscape has undergone a paradigm shift in determining safety, stability and efficacy of gene therapy approaches. In this review, we aim to summarize the progress made in the gene therapy trials targeting ADA-SCID, SCID-X1, CGD and WAS, review the pitfalls, and outline the recent advancements which are expected to further enhance favourable risk benefit ratios for gene therapeutic approaches in the future.

  11. Navigating the pitfalls and promise of landscape genetics.

    PubMed

    Richardson, Jonathan L; Brady, Steven P; Wang, Ian J; Spear, Stephen F

    2016-02-01

    The field of landscape genetics has been evolving rapidly since its emergence in the early 2000s. New applications, techniques and criticisms of techniques appear like clockwork with each new journal issue. The developments are an encouraging, and at times bewildering, sign of progress in an exciting new field of study. However, we suggest that the rapid expansion of landscape genetics has belied important flaws in the development of the field, and we add an air of caution to this breakneck pace of expansion. Specifically, landscape genetic studies often lose sight of the fundamental principles and complex consequences of gene flow, instead favouring simplistic interpretations and broad inferences not necessarily warranted by the data. Here, we describe common pitfalls that characterize such studies, and provide practical guidance to improve landscape genetic investigation, with careful consideration of inferential limits, scale, replication, and the ecological and evolutionary context of spatial genetic patterns. Ultimately, the utility of landscape genetics will depend on translating the relationship between gene flow and landscape features into an understanding of long-term population outcomes. We hope the perspective presented here will steer landscape genetics down a more scientifically sound and productive path, garnering a field that is as informative in the future as it is popular now.

  12. Pitfalls in the diagnosis of multiple sulfatase deficiency.

    PubMed

    Mancini, G M; van Diggelen, O P; Huijmans, J G; Stroink, H; de Coo, R F

    2001-02-01

    Multiple sulfatase deficiency (MSD, OMIM 272200) is an autosomal recessive leukodystrophy associated with the deficiency of several, in total seven, sulfatases. The disorder is clinically and biochemically variable. The clinical picture combines features of mucopolysaccharidosis and metachromatic leukodystrophy (MLD, OMIM 250100) in a variable spectrum. Here we report a 3-year old Iranian girl with an MLD-like presentation of MSD. Arylsulfatase A deficiency and sulfatide excretion were found. Differently from what was previously reported in the literature, this girl never showed abnormal mucopolysaccharide excretion in the urine. There were no additional visceral or skeletal signs. She was originally diagnosed as having MLD. Only when she developed ichthyosis were seven additional sulfatases measured. In leukocytes, arylsulfatase A, steroid sulfatase and N-acetylglucosamine-6 sulfatase were profoundly deficient, while iduronate-2 sulfatase and arylsulfatase B were moderately reduced. In fibroblasts, N-acetylglucosamine-6 sulfatase was deficient, while arylsulfatase A was moderately reduced. This case illustrates the possible pitfalls in the clinical and laboratory diagnosis of MSD.

  13. Lumbar Disc Degenerative Disease: Disc Degeneration Symptoms and Magnetic Resonance Image Findings

    PubMed Central

    Saleem, Shafaq; Rehmani, Muhammad Asim Khan; Raees, Aisha; Alvi, Arsalan Ahmad; Ashraf, Junaid

    2013-01-01

    Study Design Cross sectional and observational. Purpose To evaluate the different aspects of lumbar disc degenerative disc disease and relate them with magnetic resonance image (MRI) findings and symptoms. Overview of Literature Lumbar disc degenerative disease has now been proven as the most common cause of low back pain throughout the world. It may present as disc herniation, lumbar spinal stenosis, facet joint arthropathy or any combination. Presenting symptoms of lumbar disc degeneration are lower back pain and sciatica which may be aggravated by standing, walking, bending, straining and coughing. Methods This study was conducted from January 2012 to June 2012. Study was conducted on the diagnosed patients of lumbar disc degeneration. Diagnostic criteria were based upon abnormal findings in MRI. Patients with prior back surgery, spine fractures, sacroiliac arthritis, metabolic bone disease, spinal infection, rheumatoid arthritis, active malignancy, and pregnancy were excluded. Results During the targeted months, 163 patients of lumbar disc degeneration with mean age of 43.92±11.76 years, came into Neurosurgery department. Disc degeneration was most commonly present at the level of L4/L5 105 (64.4%).Commonest types of disc degeneration were disc herniation 109 (66.9%) and lumbar spinal stenosis 37 (22.7%). Spondylolisthesis was commonly present at L5/S1 10 (6.1%) and associated mostly with lumbar spinal stenosis 7 (18.9%). Conclusions Results reported the frequent occurrence of lumbar disc degenerative disease in advance age. Research efforts should endeavor to reduce risk factors and improve the quality of life. PMID:24353850

  14. The role of disc self-gravity in circumbinary planet systems - I. Disc structure and evolution

    NASA Astrophysics Data System (ADS)

    Mutter, Matthew M.; Pierens, Arnaud; Nelson, Richard P.

    2017-03-01

    We present the results of two-dimensional hydrodynamic simulations of self-gravitating circumbinary discs around binaries whose parameters match those of the circumbinary planet-hosting systems Kepler-16, Kepler-34 and Kepler-35. Previous work has shown that non-self-gravitating discs in these systems form an eccentric precessing inner cavity due to tidal truncation by the binary, and planets which form at large radii migrate until stalling at this cavity. Whilst this scenario appears to provide a natural explanation for the observed orbital locations of the circumbinary planets, previous simulations have failed to match the observed planet orbital parameters. The aim of this work is to examine the role of self-gravity in modifying circumbinary disc structure as a function of disc mass, prior to considering the evolution of embedded circumbinary planets. In agreement with previous work, we find that for disc masses between one and five times the minimum mass solar nebula (MMSN), disc self-gravity affects modest changes in the structure and evolution of circumbinary discs. Increasing the disc mass to 10 or 20 MMSN leads to two dramatic changes in disc structure. First, the scale of the inner cavity shrinks substantially, bringing its outer edge closer to the binary. Secondly, in addition to the eccentric inner cavity, additional precessing eccentric ring-like features develop in the outer regions of the discs. If planet formation starts early in the disc lifetime, these changes will have a significant impact on the formation and evolution of planets and precursor material.

  15. Bed bug (Heteroptera: Cimicidae) attraction to pitfall traps baited with carbon dioxide, heat, and chemical lure.

    PubMed

    Wang, Changlu; Gibb, Timothy; Bennett, Gary W; McKnight, Susan

    2009-08-01

    Carbon dioxide (CO2), heat, and chemical lure (1-octen-3-ol and L-lactic acid) were tested as attractants for bed bugs, Cimex lectularius L. (Heteroptera: Cimicidae), by using pitfall traps. Both CO2 and heat were attractive to bed bugs. CO2 was significantly more attractive to bed bugs than heat. Traps baited with chemical lure attracted more bed bugs but at a statistically nonsignificant level. In small arena studies (56 by 44 cm), pitfall traps baited with CO2 or heat trapped 79.8 +/- 6.7 and 51.6 +/- 0.9% (mean +/- SEM) of the bed bugs after 6 h, respectively. Traps baited with CO2 + heat, CO, + chemical lure, or CO2 + heat + chemical lure captured > or = 86.7% of the bed bugs after 6 h, indicating baited pitfall traps were highly effective in attracting and capturing bed bugs from a short distance. In 3.1- by 1.8-m environmental chambers, a pitfall trap baited with CO, + heat + chemical lure trapped 57.3 +/- 6.4% of the bed bugs overnight. The pitfall trap was further tested in four bed bug-infested apartments to determine its efficacy in detecting light bed bug infestations. Visual inspections found an average of 12.0 +/- 5.4 bed bugs per apartment. The bed bugs that were found by visual inspections were hand-removed during inspections. A pitfall trap baited with CO2 and chemical lure was subsequently placed in each apartment with an average of 15.0 +/- 6.4 bed bugs collected per trap by the next morning. We conclude that baited pitfall traps are potentially effective tools for evaluating bed bug control programs and detecting early bed bug infestations.

  16. DENVER DISC FILTER IN CO91107, SHOWING FIVE DOUBLESIDED DISCS AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DENVER DISC FILTER IN CO-91-107, SHOWING FIVE DOUBLE-SIDED DISCS AND DRIVE MOTOR. NOTE FOUR VERTICAL SLURRY FEED PIPES FROM OVERHEAD MANIFOLD AND SUCTION PIPE IN FOREGROUND. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO

  17. Preparation of ormetoprim-sulfadimethoxine-medicated discs for disc diffusion assay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Romet ( a blend of ormetoprim and sulfadimethoxine) is a type A medicated article for the manufacture of medicated feed in the catfish industry. Recently, the commercial manufacture of ormetoprim-sulfadimethoxine susceptibility discs was discontinued. Ormetoprim-sulfadimethoxine discs were prepare...

  18. Colours of bulges and discs within galaxy clusters and the signature of disc fading on infall

    NASA Astrophysics Data System (ADS)

    Hudson, Michael J.; Stevenson, Jeffrey B.; Smith, Russell J.; Wegner, Gary A.; Lucey, John R.; Simard, Luc

    2010-11-01

    The origins of the bulge and disc components of galaxies are of primary importance to understanding galaxy formation. Here bulge-disc decomposition is performed simultaneously in B and R bands for 922 bright galaxies in eight nearby (z < 0.06) clusters with deep redshift coverage using photometry from the National Optical Astronomy Observatory (NOAO) Fundamental Plane Survey. The total galaxy colours follow a universal colour-magnitude relation (CMR). The discs of L* galaxies are 0.24 mag bluer in B - R than bulges. Bulges have a significant CMR slope while the CMR slope of discs is flat. Thus the slope of the CMR of the total light is driven primarily (60 per cent) by the bulge CMR, and to a lesser extent (40 per cent) by the change in the bulge-to-total ratio as a function of magnitude. The colours of the bulge and disc components do not depend on the bulge-to-total ratio, for galaxies with bulge-to-total ratios greater than 0.2. While the colours of the bulge components do not depend significantly on environment, the median colours of discs vary significantly, with discs in the cluster centre redder by 0.10 mag than those at the virial radius. Thus while star formation in bulges appears to be regulated primarily by mass-dependent, and hence presumably internal, processes, that of discs is affected by the cluster environment.

  19. Modeling and optimization of an elastic arthroplastic disc for a degenerated disc

    NASA Astrophysics Data System (ADS)

    Ghouchani, Azadeh; Ravari, Mohammad; Mahmoudi, Farid

    2011-10-01

    A three-dimensional finite element model (FEM) of the L3-L4 motion segment using ABAQUS v 6.9 has been developed. The model took into account the material nonlinearities and is imposed different loading conditions. In this study, we validated the model by comparison of its predictions with several sets of experimental data. Disc deformation under compression and segmental rotational motions under moment loads for the normal disc model agreed well with the corresponding in vivo studies. By linking ABAQUS with MATLAB 2010.a, we determined the optimal Young s modulus as well as the Poisson's ratio for the artificial disc under different physiologic loading conditions. The results of the present study confirmed that a well-designed elastic arthroplastic disc preferably has an annulus modulus of 19.1 MPa and 1.24 MPa for nucleus section and Poisson ratio of 0.41 and 0.47 respectively. Elastic artificial disc with such properties can then achieve the goal of restoring the disc height and mechanical function of intact disc under different loading conditions and so can reduce low back pain which is mostly caused due to disc degeneration.

  20. Immediate total tooth replacement.

    PubMed

    Garber, D A; Salama, M A; Salama, H

    2001-03-01

    Successful implant placement at the time of extraction has been documented. Implant placement at the time of extraction was initially performed as a two-stage procedure often with barrier membranes and sophisticated second-stage surgical uncoverings. The authors describe the next generation of this technique, including atraumatic tooth removal with simultaneous root form, implant placement, and temporization at one appointment. This technique of "Immediate Total Tooth Replacement" allows for the maintenance of the bony housing and soft-tissue form that existed before extraction, while at the same time establishing a root form anchor in the bone for an esthetic restoration.

  1. Total ankle joint replacement.

    PubMed

    2016-02-01

    Ankle arthritis results in a stiff and painful ankle and can be a major cause of disability. For people with end-stage ankle arthritis, arthrodesis (ankle fusion) is effective at reducing pain in the shorter term, but results in a fixed joint, and over time the loss of mobility places stress on other joints in the foot that may lead to arthritis, pain and dysfunction. Another option is to perform a total ankle joint replacement, with the aim of giving the patient a mobile and pain-free ankle. In this article we review the efficacy of this procedure, including how it compares to ankle arthrodesis, and consider the indications and complications.

  2. Structures induced by companions in galactic discs

    NASA Astrophysics Data System (ADS)

    Kyziropoulos, P. E.; Efthymiopoulos, C.; Gravvanis, G. A.; Patsis, P. A.

    2016-12-01

    Using N-body simulations, we study the structures induced on a galactic disc by repeated flybys of a companion in decaying eccentric orbit around the disc. Our system is composed of a stellar disc, bulge and live dark matter halo, and we study the system's dynamical response to a sequence of a companion's flybys, when we vary (i) the disc's temperature (parametrized by Toomre's Q-parameter) and (ii) the companion's mass and initial orbit. We use a new 3D Cartesian grid code: MAIN (Mesh-adaptive Approximate Inverse N-body solver). The main features of MAIN are reviewed, with emphasis on the use of a new Symmetric Factored Approximate Sparse Inverse matrix in conjunction with the multigrid method that allows the efficient solution of Poisson's equation in three space variables. We find that (i) companions need to be assigned initial masses in a rather narrow window of values in order to produce significant and more long-standing non-axisymmetric structures (bars and spirals) in the main galaxy's disc by the repeated flyby mechanism. (ii) A crucial phenomenon is the antagonism between companion-excited and self-excited modes on the disc. Values of Q > 1.5 are needed in order to allow for the growth of the companion-excited modes to prevail over the growth of the disc's self-excited modes. (iii) We give evidence that the companion-induced spiral structure is best represented by a density wave with pattern speed nearly constant in a region extending from the inner Lindblad resonance to a radius close to, but inside, corotation.

  3. Cervical disc hernia operations through posterior laminoforaminotomy

    PubMed Central

    Yolas, Coskun; Ozdemir, Nuriye Guzin; Okay, Hilmi Onder; Kanat, Ayhan; Senol, Mehmet; Atci, Ibrahim Burak; Yilmaz, Hakan; Coban, Mustafa Kemal; Yuksel, Mehmet Onur; Kahraman, Umit

    2016-01-01

    Objective: The most common used technique for posterolateral cervical disc herniations is anterior approach. However, posterior cervical laminotoforaminomy can provide excellent results in appropriately selected patients with foraminal stenosis in either soft disc prolapse or cervical spondylosis. The purpose of this study was to present the clinical outcomes following posterior laminoforaminotomy in patients with radiculopathy. Materials and Methods: We retrospectively evaluated 35 patients diagnosed with posterolateral cervical disc herniation and cervical spondylosis with foraminal stenosis causing radiculopathy operated by the posterior cervical keyhole laminoforaminotomy between the years 2010 and 2015. Results: The file records and the radiographic images of the 35 patients were assessed retrospectively. The mean age was 46.4 years (range: 34-66 years). Of the patients, 19 were males and 16 were females. In all of the patients, the neurologic deficit observed was radiculopathy. The posterolaterally localized disc herniations and the osteophytic structures were on the left side in 18 cases and on the right in 17 cases. In 10 of the patients, the disc level was at C5-6, in 18 at C6-7, in 2 at C3-4, in 2 at C4-5, in 1 at C7-T1, in 1 patient at both C5-6 and C6-7, and in 1 at both C4-5 and C5-6. In 14 of these 35 patients, both osteophytic structures and protruded disc herniation were present. Intervertebral foramen stenosis was present in all of the patients with osteophytes. Postoperatively, in 31 patients the complaints were relieved completely and four patients had complaints of neck pain and paresthesia radiating to the arm (the success of operation was 88.5%). On control examinations, there was no finding of instability or cervical kyphosis. Conclusion: Posterior cervical laminoforaminotomy is an alternative appropriate choice in both cervical soft disc herniations and cervical stenosis. PMID:27217655

  4. Reconstructing the star formation history of the Milky Way disc(s) from chemical abundances

    NASA Astrophysics Data System (ADS)

    Snaith, O.; Haywood, M.; Di Matteo, P.; Lehnert, M. D.; Combes, F.; Katz, D.; Gómez, A.

    2015-06-01

    We develop a chemical evolution model to study the star formation history of the Milky Way. Our model assumes that the Milky Way has formed from a closed-box-like system in the inner regions, while the outer parts of the disc have experienced some accretion. Unlike the usual procedure, we do not fix the star formation prescription (e.g. Kennicutt law) to reproduce the chemical abundance trends. Instead, we fit the abundance trends with age to recover the star formation history of the Galaxy. Our method enables us to recover the star formation history of the Milky Way in the first Gyrs with unprecedented accuracy in the inner (R < 7-8 kpc) and outer (R > 9-10 kpc) discs, as sampled in the solar vicinity. We show that half the stellar mass formed during the thick-disc phase in the inner galaxy during the first 4-5 Gyr. This phase was followed by a significant dip in star formation activity (at 8-9 Gyr) and a period of roughly constant lower-level star formation for the remaining 8 Gyr. The thick-disc phase has produced as many metals in 4 Gyr as the thin-disc phase in the remaining 8 Gyr. Our results suggest that a closed-box model is able to fit all the available constraints in the inner disc. A closed-box system is qualitatively equivalent to a regime where the accretion rate maintains a high gas fraction in the inner disc at high redshift. In these conditions the SFR is mainly governed by the high turbulence of the interstellar medium. By z ~ 1 it is possible that most of the accretion takes place in the outer disc, while the star formation activity in the inner disc is mostly sustained by the gas that is not consumed during the thick-disc phase and the continuous ejecta from earlier generations of stars. The outer disc follows a star formation history very similar to that of the inner disc, although initiated at z ~ 2, about 2 Gyr before the onset of the thin-disc formation in the inner disc.

  5. [Longterm results of cervical arthroplasty with disc prosthesis. A literature review].

    PubMed

    Fransen, P; Schils, F

    2014-01-01

    Cervical arthroplasty has now been performed for over 10 years. Despite the large number of implanted artificial discs, the quality of the published studies is weak, and very few report a follow up exceeding two years. We reviewed the literature on cervical total disc replacement, focusing on publications reporting a follow-up of more than two years. The selection of patients, the type of implant and the surgical technique seem to influence greatly the quality of the clinical and radiological results. The occurrence of heterotopic ossifications around the implant seems to be the rule rather than the exception. Wear debris are likely to be observed in the vicinity of the prosthesis. Most long term studies also report a progressive decrease in the range of motion of the prosthesis, although without influence on the clinical evolution. It seems reasonable to say that cervical disc prosthesis is not inferior to discectomy and fusion, and that these implants allow a short term preservation of cervical mobility, but the efficacy in preventing adjacent segment disease or a favourable costleffectiveness ratio have yet to be demonstrated. A more widespread use of cervical disc prosthesis can only be suggested when these questions have been answered by long term follow-up studies.

  6. A test of truncation in the accretion discs of X-ray Binaries.

    NASA Astrophysics Data System (ADS)

    Eckersall, A.

    2016-06-01

    The truncated-disc model is generally used to help explain the change between the soft and hard states in X-ray Binaries, where the standard accretion disc is truncated in the inner regions and replaced by a radiatively inefficient accretion flow. There is still disagreement though in the extent of this truncation, particularly in at what point truncation begins. Here we analyze XMM EPIC-pn spectra in both the soft and hard states for a number of galactic XRBs, along with RGS data and the latest absorption and emission models to get an independent fit for the ISM column densities for each source. Specifically, we assume the 'canonical' model where the luminous accretion disc extends down to the innermost stable orbit at 6r_g, and construct a spectral model accounting for thermal, reflection and Compton processes ensuring consistent geometrical properties of the models. Rather than attempting to infer the inner disc location from spectral fitting and/or reflection models, we instead attempt a direct test of whether a consistent model will fit assuming no truncation. We discuss the implications for emission models of XRBs.

  7. TU-D-BRD-01: Image Guided SBRT II: Challenges ' Pitfalls

    SciTech Connect

    Chang, Z; Yin, F; Cho, J

    2014-06-15

    Stereotactic body radiation therapy (SBRT) has been effective treatment for the management of various diseases, which often delivers high radiation dose in a single or a few fractions. SBRT therefore demands precise treatment delivery to the tumor while sparing adjacent healthy tissue. Recent developments in image guidance enable target localization with increased accuracy. With such improvements in localization, image-guided SBRT has been widely adopted into clinical practice. In SBRT, high radiation dose is generally delivered with small fields. Therefore, it is crucial to accurately measure dosimetric data for the small fields during commissioning. In addition, image-guided SBRT demands accurate image localization to ensure safety and quality of patient care. Lately, the reports of AAPM TG 142 and TG 104 have been published and added recommendations for imaging devices that are integrated with the linear accelerator for SBRT. Furthermore, various challenges and potential pitfalls lie in the clinical implementation of image-guided SBRT. In this lecture, these challenges and pitfalls of image-guided SBRT will be illustrated and discussed from dosimetric, technical and clinical perspectives.Being a promising technique, image-guided SBRT has shown great potentials, and will lead to more accurate and safer SBRT treatments. Learning Objectives: To understand dosimetric challenges and pitfalls for IGRT application in SBRT. To understand major clinical challenges and pitfalls for IGRT application in SBRT. To understand major technical challenges and pitfalls for IGRT application in SBRT.

  8. Pitfalls in RECIST Data Extraction for Clinical Trials: Beyond the Basics.

    PubMed

    Abramson, Richard G; McGhee, Carrie R; Lakomkin, Nikita; Arteaga, Carlos L

    2015-06-01

    Response Evaluation Criteria in Solid Tumors (RECIST) is a standardized methodology for determining therapeutic response to anticancer therapy using changes in lesion appearance on imaging studies. Many radiologists are now using RECIST in their routine clinical workflow, as part of consultative arrangements, or within dedicated imaging core laboratories. Although basic RECIST methodology is well described in published articles and online resources, inexperienced readers may encounter difficulties with certain nuances and subtleties of RECIST. This article illustrates a set of pitfalls in RECIST assessment considered to be "beyond the basics." These pitfalls were uncovered during a quality improvement review of a recently established cancer imaging core laboratory staffed by radiologists with limited prior RECIST experience. Pitfalls are presented in four categories: (1) baseline selection of lesions, (2) reassessment of target lesions, (3) reassessment of nontarget lesions, and (4) identification of new lesions. Educational and operational strategies for addressing these pitfalls are suggested. Attention to these pitfalls and strategies may improve the overall quality of RECIST assessments performed by radiologists.

  9. Power Plant Replacement Study

    SciTech Connect

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self‐funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty‐three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  10. Power Plant Replacement Study

    SciTech Connect

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  11. Cadmium plating replacements

    SciTech Connect

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  12. Power Plant Replacement Study

    SciTech Connect

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University's aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  13. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  14. Sutureless aortic valve replacement

    PubMed Central

    Phan, Kevin

    2015-01-01

    The increasing incidence of aortic stenosis and greater co-morbidities and risk profiles of the contemporary patient population has driven the development of minimally invasive aortic valve surgery and percutaneous transcatheter aortic valve implantation (TAVI) techniques to reduce surgical trauma. Recent technological developments have led to an alternative minimally invasive option which avoids the placement and tying of sutures, known as “sutureless” or rapid deployment aortic valves. Potential advantages for sutureless aortic prostheses include reducing cross-clamp and cardiopulmonary bypass (CPB) duration, facilitating minimally invasive surgery and complex cardiac interventions, whilst maintaining satisfactory hemodynamic outcomes and low paravalvular leak rates. However, given its recent developments, the majority of evidence regarding sutureless aortic valve replacement (SU-AVR) is limited to observational studies and there is a paucity of adequately-powered randomized studies. Recently, the International Valvular Surgery Study Group (IVSSG) has formulated to conduct the Sutureless Projects, set to be the largest international collaborative group to investigate this technology. This keynote lecture will overview the use, the potential advantages, the caveats, and current evidence of sutureless and rapid deployment aortic valve replacement (AVR). PMID:25870807

  15. Parametric modeling of the intervertebral disc space in 3D: application to CT images of the lumbar spine.

    PubMed

    Korez, Robert; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-10-01

    Gradual degeneration of intervertebral discs of the lumbar spine is one of the most common causes of low back pain. Although conservative treatment for low back pain may provide relief to most individuals, surgical intervention may be required for individuals with significant continuing symptoms, which is usually performed by replacing the degenerated intervertebral disc with an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study, we propose a method for parametric modeling of the intervertebral disc space in three dimensions (3D) and show its application to computed tomography (CT) images of the lumbar spine. The initial 3D model of the intervertebral disc space is generated according to the superquadric approach and therefore represented by a truncated elliptical cone, which is initialized by parameters obtained from 3D models of adjacent vertebral bodies. In an optimization procedure, the 3D model of the intervertebral disc space is incrementally deformed by adding parameters that provide a more detailed morphometric description of the observed shape, and aligned to the observed intervertebral disc space in the 3D image. By applying the proposed method to CT images of 20 lumbar spines, the shape and pose of each of the 100 intervertebral disc spaces were represented by a 3D parametric model. The resulting mean (±standard deviation) accuracy of modeling was 1.06±0.98mm in terms of radial Euclidean distance against manually defined ground truth points, with the corresponding success rate of 93% (i.e. 93 out of 100 intervertebral disc spaces were modeled successfully). As the resulting 3D models provide a description of the shape of intervertebral disc spaces in a complete parametric form, morphometric analysis was straightforwardly enabled and allowed the computation of the corresponding

  16. Design concepts in lumbar total disc arthroplasty

    PubMed Central

    Bellini, Chiara M.; Zweig, Thomas; Ferguson, Stephen; Raimondi, Manuela T.; Lamartina, Claudio; Brayda-Bruno, Marco; Fornari, Maurizio

    2008-01-01

    The implantation of lumbar disc prostheses based on different design concepts is widely accepted. This paper reviews currently available literature studies on the biomechanics of TDA in the lumbar spine, and is targeted at the evaluation of possible relationships between the aims of TDA and the geometrical, mechanical and material properties of the various available disc prostheses. Both theoretical and experimental studies were analyzed, by a PUBMED search (performed in February 2007, revised in January 2008), focusing on single level TDA. Both semi-constrained and unconstrained lumbar discs seem to be able to restore nearly physiological IAR locations and ROM values. However, both increased and decreased ROM was stated in some papers, unrelated to the clinical outcome. Segmental lordosis alterations after TDA were reported in most cases, for both constrained and unconstrained disc prostheses. An increase in the load through the facet joints was documented, for both semi-constrained and unconstrained artificial discs, but with some contrasting results. Semi-constrained devices may be able to share a greater part of the load, thus protecting the surrounding biological structure from overloading and possible early degeneration, but may be more susceptible to wear. The next level of development will be the biomechanical integration of compression across the motion segment. All these findings need to be supported by long-term clinical outcome studies. PMID:18946684

  17. Lubrication regimes in lumbar total disc arthroplasty.

    PubMed

    Shaheen, A; Shepherd, D E T

    2007-08-01

    A number of total disc arthroplasty devices have been developed. Some concern has been expressed that wear may be a potential failure mode for these devices, as has been seen with hip arthroplasty. The aim of this paper was to investigate the lubrication regimes that occur in lumbar total disc arthroplasty devices. The disc arthroplasty was modelled as a ball-and-socket joint. Elastohydrodynamic lubrication theory was used to calculate the minimum film thickness of the fluid between the bearing surfaces. The lubrication regime was then determined for different material combinations, size of implant, and trunk velocity. Disc arthroplasties with a metal-polymer or metal-metal material combination operate with a boundary lubrication regime. A ceramic-ceramic material combination has the potential to operate with fluid-film lubrication. Disc arthroplasties with a metal-polymer or metal-metal material combination are likely to generate wear debris. In future, it is worth considering a ceramic-ceramic material combination as this is likely to reduce wear.

  18. Data interpretation in breath biomarker research: pitfalls and directions.

    PubMed

    Miekisch, Wolfram; Herbig, Jens; Schubert, Jochen K

    2012-09-01

    Most--if not all--potential diagnostic applications in breath research involve different marker concentrations rather than unique breath markers which only occur in the diseased state. Hence, data interpretation is a crucial step in breath analysis. To avoid artificial significance in breath testing every effort should be made to implement method validation, data cross-testing and statistical validation along this process. The most common data analysis related problems can be classified into three groups: confounding variables (CVs), which have a real correlation with both the diseased state and a breath marker but lead to the erroneous conclusion that disease and breath are in a causal relationship; voodoo correlations (VCs), which can be understood as statistically true correlations that arise coincidentally in the vast number of measured variables; and statistical misconceptions in the study design (SMSD). CV: Typical confounding variables are environmental and medical history, host factors such as gender, age, weight, etc and parameters that could affect the quality of breath data such as subject breathing mode, effects of breath sampling and effects of the analytical technique itself. VC: The number of measured variables quickly overwhelms the number of samples that can feasibly be taken. As a consequence, the chances of finding coincidental 'voodoo' correlations grow proportionally. VCs can typically be expected in the following scenarios: insufficient number of patients, (too) many measurement variables, the use of advanced statistical data mining methods, and non-independent data for validation. SMSD: Non-prospective, non-blinded and non-randomized trials, a priori biased study populations or group selection with unrealistically high disease prevalence typically represent misconception of study design. In this paper important data interpretation issues are discussed, common pitfalls are addressed and directions for sound data processing and interpretation

  19. Animal models of protein allergenicity: potential benefits, pitfalls and challenges.

    PubMed

    Dearman, R J; Kimber, I

    2009-04-01

    Food allergy is an important health issue. With an increasing interest in novel foods derived from transgenic crop plants, there is a growing need for the development of approaches suitable for the characterization of the allergenic potential of proteins. There are methods available currently (such as homology searches and serological testing) that are very effective at identifying proteins that are likely to cross-react with known allergens. However, animal models may play a role in the identification of truly novel proteins, such as bacterial or fungal proteins, that have not been experienced previously in the diet. We consider here the potential benefits, pitfalls and challenges of the selection of various animal models, including the mouse, the rat, the dog and the neonatal swine. The advantages and disadvantages of various experimental end-points are discussed, including the measurement of specific IgE by ELISA, Western blotting or functional tests such as the passive cutaneous anaphylaxis assay, and the assessment of challenge-induced clinical symptoms in previously sensitized animals. The experimental variables of route of exposure to test proteins and the incorporation of adjuvant to increase the sensitivity of the responses are considered also. It is important to emphasize that currently none of these approaches has been validated for the purposes of hazard identification in the context of a safety assessment. However, the available evidence suggests that the judicious use of an accurate and robust animal model could provide important additional data that would contribute significantly to the assessment of the potential allergenicity of novel proteins.

  20. US of the Knee: Scanning Techniques, Pitfalls, and Pathologic Conditions.

    PubMed

    Alves, Timothy I; Girish, Gandikota; Kalume Brigido, Monica; Jacobson, Jon A

    2016-10-01

    Pain and other disorders of the knee are a common presenting complaint in the ambulatory setting. Although the cornerstones of imaging evaluation of the knee are radiographs and magnetic resonance (MR) imaging, ultrasonography (US) is less expensive than MR imaging, easily available, and of comparable accuracy in the evaluation of certain pathologic conditions of the knee. The benefits of US include portability, low cost, high spatial resolution, dynamic imaging, and ability to guide percutaneous interventions when indicated. US also allows direct patient contact, facilitating immediate clinical correlation and the ability to compare with the contralateral knee. US evaluation of the knee can be targeted to a specific region on the basis of the complaint or be a comprehensive review. For comprehensive evaluation, the knee is divided into anterior, medial, lateral, and posterior compartments for structured evaluation of the tendons, ligaments, joint space, osseous structures, as well as peripheral nerves and vasculature. US is particularly well suited for evaluating injuries of the quadriceps and patellar tendons, injuries of the medial and lateral collateral ligaments, joint effusions, and fluid collections around the knee. There is additional utility in evaluation of the distal hamstrings tendons, the iliotibial tract, the superficial patellar cortex, the common peroneal nerve, the popliteal vessels, and juxta-articular cystic collections including Baker cyst. In-depth appreciation of relevant sonographic anatomy, common pathologic conditions, knowledge of important pitfalls, and mastery of US technique will allow one to effectively use this powerful bedside tool for the evaluation of a wide variety of knee disorders. (©)RSNA, 2016.

  1. Commercialization of Seizure Prediction Technology Promises and Pitfalls of Biosignal Analysis: Seizure Prediction and Management (A case study);

    DTIC Science & Technology

    2007-11-02

    biosignals utilizing computationally intensive algorithms are useful and provide no limitation for clinical Commercialization of Seizure Prediction...Technology Promises and Pitfalls of Biosignal Analysis: Seizure Prediction and Management (A case study); Mark T. Rise, Ph.D. Technical Fellow...Title and Subtitle Commercialization of Seizure Prediction Technology Promises and Pitfalls of Biosignal Analysis: Seizure Prediction and

  2. Common Pitfalls in Exposure and Response Prevention (EX/RP) for OCD

    PubMed Central

    Gillihan, Seth J.; Williams, Monnica T.; Malcoun, Emily; Yadin, Elna; Foa, Edna B.

    2012-01-01

    Obsessive-compulsive disorder (OCD) is a highly debilitating disorder. Fortunately there are treatments that help the majority of OCD sufferers. The behavioral treatment with the most empirical support for its efficacy is exposure and response prevention (EX/RP). Over the years in our supervision meetings and in our clinical practice we have noted a number of relatively common therapist pitfalls that decrease the effectiveness of EX/RP. These pitfalls include not encouraging patients to approach the most distressing situations, doing imaginal exposure when in vivo is called for (and vice versa), encouraging distraction during exposure, providing reassurance, failing to address the core fear, ineffective handling of mental compulsions, and difficulty working with close others in the patient’s life. In the current article we describe these common pitfalls and how to avoid them. PMID:22924159

  3. Antenna grout replacement system

    NASA Technical Reports Server (NTRS)

    Mcclung, C. E. (Inventor)

    1983-01-01

    An epoxy grout suitable for use in mounting and positioning bearing runner plates used in hydrostatic bearing assemblies for rotatably mounting large radio telescope structures to stationary support pedestals is described. The epoxy grout may be used in original mountings or may be used as part of a replacement system for repairing cavities in existing grout resulting from grout deterioration. The epoxy grout has a relatively short work life and cure time even in the presence of hydraulic oil. The epoxy grout cures without shrinking or sagging to form a grout which is sufficiently strong and durable to provide a grout especially well suited for use under the high pressure loading and close tolerance requirements of large hydrostatic bearing assemblies.

  4. Functional replacements for gluten.

    PubMed

    Zannini, Emanuele; Jones, Julie Miller; Renzetti, Stefano; Arendt, Elke K

    2012-01-01

    Celiac disease (CD) is an immune-mediated disease triggered in genetically susceptible individuals by ingested gluten from wheat, rye, barley, and other closely related cereal grains. Currently, the only therapy able to normalize the clinical and histological manifestation of the disease is a strict and life-long gluten-free (GF) diet. The replacement of gluten presents a significant technological challenge, as it is an essential structure-building protein, which is necessary for formulating high-quality baked goods. The objective of this paper is to review some basics about CD, its current prevalence, and the recent advances in the preparation of high-quality GF breads using GF flours, starches, hydrocolloids, gums, and novel functional ingredients and technologies.

  5. The debris disc around HIP 17439

    NASA Astrophysics Data System (ADS)

    Schüppler, Christian; Löhne, Torsten; Krivov, Alexander

    2013-07-01

    In the framework of the Herschel Open Time Key Programme DUNES the debris disc around the K2 V star HIP 17439 was observed. In PACS images the disc emission is spatially clearly extended. A simultaneous analysis of photometric observations and radial brightness profiles from the resolved images provides valuable hints for the disc structure. In an analytical model we adopted power laws for the size and radial distribution of the circumstellar dust and tested two different scenarios: (1) a broad dust ring with a radial extent of about 200AU, (2) two independent dust rings separated by a gap of several tens of AU. Both models fit the spectral energy distribution and the radial profiles quite well. In case (1) the parameters found are consistent with dust stemming from an outer planetesimal belt at ~140AU and strong transport mechanisms that drag the particles inward. Model (2) would imply two planetesimal belts, producing a narrow inner and wider outer distribution of dust.

  6. Hormone replacement therapy and longevity.

    PubMed

    Comhaire, F

    2016-02-01

    To assess whether hormone replacement therapy influences longevity, an analysis was made of published life tables allowing for the calculation of the relative benefit of hormone replacement therapy on longevity in men with late onset hypogonadism and in post-menopausal women. It was found that testosterone replacement therapy of men suffering from late onset hypogonadism increased survival rate by 9-10% in 5 years, similar to that of eugonadal, non-LOH men with normal endogenous testosterone secretion. Oestrogen replacement therapy resulted in increased survival by 2.6% in 5 years. It is concluded that hormone replacement therapy increases longevity.

  7. Effects of disc midplane evolution on CO snowline location

    NASA Astrophysics Data System (ADS)

    Panić, O.; Min, M.

    2017-01-01

    Temperature changes in the planet forming disc midplanes carry important physico-chemical consequences, such as the effect on the locations of the condensation fronts of molecules - the snowlines. Snowlines impose major chemical gradients and possibly foster grain growth. The aim of this paper is to understand how disc midplane temperature changes with gas and dust evolution, and identify trends that may influence planet formation or allow to constrain disc evolution observationally. We calculate disc temperature, hydrostatic equilibrium and dust settling in a mutually consistent way from a grid of disc models at different stages of gas loss, grain growth and hole opening. We find that the CO snowline location depends very strongly on disc properties. The CO snowline location migrates closer to the star for increasing degrees of gas dispersal and dust growth. Around a typical A type star, the snowline can be anywhere between several tens and a few hundred au, depending on the disc properties such as gas mass and grain size. In fact, gas loss is as efficient as dust evolution in settling discs, and flat discs may be gas-poor counterparts of flared discs. Our results, in the context of different pre-main sequence evolution of the luminosity in low- and intermediate-mass stars suggests very different thermal (and hence chemical) histories in these two types of discs. Discs of T Tauri stars settle and cool down while discs of Herbig Ae stars may remain rather warm throughout the pre-main sequence.

  8. Pitfalls in animal reproduction research: how the animal guards nature's secrets.

    PubMed

    Ginther, O J

    2013-08-01

    The estrous cycles of heifers and mares are used for illustrating pitfalls at the animal level in research in reproductive biology. Infrequent monitoring for characterizing the change in hormone concentrations or for detecting a reproductive event can be a pitfall when the interval for obtaining data exceeds the interval between events. For example, hourly collection of blood samples has shown that the luteolytic period (decreasing progesterone) encompasses 24 hours in heifers and mares. Collection of samples every 6-24 hours results in the illusion that luteolysis requires 2-3 days, owing to the occurrence of luteolysis on different days in individuals. A single treatment with PGF2α that causes complete regression of the corpus luteum is an example of an overdose pitfall. A nonphysiological progesterone increase occurs and will be misleading if used for making interpretations on the nature of luteolysis. A pitfall can also occur if a chosen reference point or end point is a poor representation of a physiological event. For example, if on a selected day after ovulation the animals in treatment A are closer on average to luteolysis than animals in treatment B, treatment A will appear to have had an earlier luteolytic effect. Among the techniques that are used directly in the animal, ultrasonography appears to be most prone to research pitfalls. Research during a given month can be confounded by seasonal effects, even in species that ovulate throughout the year. The presence of unknown factors or complex interactions among factors and the sensitivity of the animal to a research procedure separate from the direct effect of a treatment are also research challenges. A hidden factor should be considered nature's challenge to open-minded biologists but a pitfall for the close-minded.

  9. Shift in apparent contrast of disc at Secchi disc depth in coastal sea areas.

    PubMed

    Arakawa, Hisayuki; Inada, Mari; Choi, Sokjin; Narita, Miho

    2013-03-01

    The relationship between Secchi disc depth and amount of suspended material in seawater varies depending on the particular marine area. To identify the cause of this dependence, we calculated the apparent contrast (C (SD)) at each Secchi disc depth in different coastal sea areas. When the turbidity from the surface to the Secchi disc depth was uniform, the C (SD) was distributed in the range of 1.3 to 0.001 for a Secchi disc depth (Z (SD)) of 2-18 m. Z (SD) tended to decrease as C (SD) became larger. The dominant wavelength for the sea color was 475-500 nm for a Secchi disc depth of 13-18 m, and 500-575 nm for a Z(SD) of 2-6 m, shifting to longer wavelengths as the Secchi disc depth increased. That is, when Z (SD) decreased, the dominant wavelength of the sea color, and the C (SD) increased simultaneously. This phenomenon seems to occur because the contrast threshold for the human eye is higher at longer wavelengths. In other words, the contrast threshold is visibly indistinguishable when the apparent contrast in ocean waters with low Secchi disc depths is high. This phenomenon occurs because the human eye is affected by the color of the sea.

  10. Disc in Flames: Roles of TNF-α and IL-1β in Intervertebral Disc Degeneration

    PubMed Central

    Johnson, Zariel I.; Schoepflin, Zachary R.; Choi, Hyowon; Shapiro, Irving M.; Risbud, Makarand V.

    2016-01-01

    The intervertebral disc is an important mechanical structure that allows range of motion of the spinal column. Degeneration of the intervertebral disc, incited by aging, traumatic insult, genetic predisposition, or other factors, is often defined by functional and structural changes in the tissue, including excessive breakdown of the extracellular matrix, increased disc cell senescence and death, and compromised biomechanical function of the tissue. Intervertebral disc degeneration is strongly correlated with low back pain, which is a highly prevalent and costly condition, significantly contributing to loss in productivity and health care costs. Disc degeneration is a chronic, progressive condition, and current therapies are limited and often focused on symptomatic pain relief rather than curtailing the progression of the disease. Inflammatory processes, exacerbated by cytokines TNF-α and IL-1β are believed to be key mediators of disc degeneration and low back pain. In this review, we describe the contributions of TNF-α and IL-1β to changes seen during disc degeneration at the cellular and tissue level, new evidence suggesting a link between infection of the spine and low back pain, and the emerging therapeutic modalities aimed at combating these processes. PMID:26388614

  11. Cometary ices in forming protoplanetary disc midplanes

    NASA Astrophysics Data System (ADS)

    Drozdovskaya, Maria N.; Walsh, Catherine; van Dishoeck, Ewine F.; Furuya, Kenji; Marboeuf, Ulysse; Thiabaud, Amaury; Harsono, Daniel; Visser, Ruud

    2016-10-01

    Low-mass protostars are the extrasolar analogues of the natal Solar system. Sophisticated physicochemical models are used to simulate the formation of two protoplanetary discs from the initial prestellar phase, one dominated by viscous spreading and the other by pure infall. The results show that the volatile prestellar fingerprint is modified by the chemistry en route into the disc. This holds relatively independent of initial abundances and chemical parameters: physical conditions are more important. The amount of CO2 increases via the grain-surface reaction of OH with CO, which is enhanced by photodissociation of H2O ice. Complex organic molecules are produced during transport through the envelope at the expense of CH3OH ice. Their abundances can be comparable to that of methanol ice (few per cent of water ice) at large disc radii (R > 30 au). Current Class II disc models may be underestimating the complex organic content. Planet population synthesis models may underestimate the amount of CO2 and overestimate CH3OH ices in planetesimals by disregarding chemical processing between the cloud and disc phases. The overall C/O and C/N ratios differ between the gas and solid phases. The two ice ratios show little variation beyond the inner 10 au and both are nearly solar in the case of pure infall, but both are subsolar when viscous spreading dominates. Chemistry in the protostellar envelope en route to the protoplanetary disc sets the initial volatile and prebiotically significant content of icy planetesimals and cometary bodies. Comets are thus potentially reflecting the provenances of the midplane ices in the solar nebula.

  12. Mesenchymal stem cells injection in degenerated intervertebral disc: cell leakage may induce osteophyte formation.

    PubMed

    Vadalà, Gianluca; Sowa, Gwendolyn; Hubert, Mark; Gilbertson, Lars G; Denaro, Vincenzo; Kang, James D

    2012-05-01

    Recent studies have shown that mesenchymal stem cell (MSC)-based therapy might be an effective approach for the treatment of intervertebral disc degeneration (IDD). However, many unanswered questions remain before clinical translation, such as the most effective stem cell type, a reliable transplantation method, including the carrier choice, and the fate of stem cells after misdirected delivery, among others. The objective of the study was to evaluate the fate and effect of allogenic bone marrow MSCs after transplantation into an IDD model. The L2-3, L3-4 and L4-5 intervertebral discs (IVDs) of four rabbits were stabbed to create IDD. Rabbit MSCs were expanded in vitro and in part transduced with retrovirus/eGFP. After 3 weeks, 1 × 10(5) MSCs were injected into the IVDs. The rabbits were followed by X-ray and MRI 3 and 9 weeks after injection. Then the animals were sacrificed and the spines analysed histologically. MRI showed no signs of regeneration. X-ray and gross anatomy inspection demonstrated large anterolateral osteophytes. Histological analysis showed that the osteophytes were composed of mineralized tissue surrounded by chondrocytes, with the labelled MSCs among the osteophyte-forming cells. The labelled MSCs were not found in the nucleus. Inflammatory cells were not observed in any injected IVDs. These results raise concern that MSCs can migrate out of the nucleus and undesirable bone formation may occur. While cause cannot be inferred from this study, the presence of MSCs in the osteophytes suggests a potential side-effect with this approach. IVD regeneration strategies need to focus on cell carrier systems and annulus-sealing technologies to avoid pitfalls.

  13. Novel associated hydrogels for nucleus pulposus replacement.

    PubMed

    Thomas, Jonathan; Lowman, Anthony; Marcolongo, Michele

    2003-12-15

    Hydrogels of poly(vinyl alcohol) (PVA) and poly(vinyl pyrrolidone) (PVP) blends may provide a material suitable for replacement of the nucleus pulposus of the intervertebral disc. This research examined the stability of these hydrogels under simulated physiological conditions. Polymer dissolution and stability were characterized over 120 days immersion, chemical surface analysis over 56 days immersion, and tensile mechanical behavior over 56 days immersion. Rubber elasticity theory was used by combining mechanical results with swelling data to calculate network characteristics such as the molecular weight between physical crosslinks and density of crosslinks. Properties were examined as a function of PVA/PVP composition as well as PVA molecular weight and PVP molecular weight. Results indicated that PVA/PVP blends prepared with moderate amounts of PVP (0.5-5%) resulted in a polymer network stabilized through interchain hydrogen bonding between hydroxyl groups on PVA chains and carbonyl groups on PVP chains. Most notably, a significant decrease in percentage of polymer mass loss was seen for blends prepared with 143K molecular weight PVA. Surface chemical analysis revealed that PVP unincorporated in the network structure suffered significant dissolution out of the polymer network and into solution. The molecular weight of PVA and PVP were shown to have a significant influence on the blends' network properties. Gels prepared with lower molecular weight PVA resulted in a more stable blend containing a higher density of crosslinks. However, blends prepared with a higher molecular weight PVA showed superior polymer network stability in dissolution studies. The blend that had the best combination of network stability under physiological conditions and a relatively tight, stable, and crosslinked network was prepared with 99% PVA (143K) and 1% PVP (40K). This material is proposed as an implant material for replacement of the degenerated nucleus pulposus.

  14. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls.

    PubMed

    Taslakian, Bedros; Latson, Larry A; Truong, Mylene T; Aaltonen, Eric; Shiau, Maria C; Girvin, Francis; Alpert, Jeffrey B; Wickstrom, Maj; Ko, Jane P

    2016-11-01

    Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  15. Aerodynamic investigations of a disc-wing

    NASA Astrophysics Data System (ADS)

    Dumitrache, Alexandru; Frunzulica, Florin; Grigorescu, Sorin

    2017-01-01

    The purpose of this paper is to evaluate the aerodynamic characteristics of a wing-disc, for a civil application in the fire-fighting system. The aerodynamic analysis is performed using a CFD code, named ANSYS Fluent, in the flow speed range up to 25 m/s, at lower and higher angle of attack. The simulation is three-dimensional, using URANS completed by a SST turbulence model. The results are used to examine the flow around the disc with increasing angle of attack and the structure of the wake.

  16. Splint-assisted disc plication surgery

    PubMed Central

    Sheikh, Omar; Logan, Greg; Komath, Deepak; Grossman, Patrick; Ayliffe, Peter

    2016-01-01

    Summary Chronic disc displacement may lead to long-term pain. Temporomandibular joint surgery is reserved for those patients whose symptoms remain severe despite conservative treatment. We looked at the of effect of modified meniscopexy on patients with chronic disc displacement without reduction who did not respond to non-surgical pain management treatment. In this retrospective study a total of 59 joints was treated and all patients except one underwent splint assisted bilateral meniscopexy: this patient had splint assisted unilateral meniscopexy. At the time of presentation and following treatment all patients underwent clinical examination and were required to complete a pain and functional questionnaire. All patients reported improvement following treatment. PMID:28149454

  17. Disc valve for sampling erosive process streams

    DOEpatents

    Mrochek, J.E.; Dinsmore, S.R.; Chandler, E.W.

    1986-01-07

    A four-port disc valve is described for sampling erosive, high temperature process streams. A rotatable disc defining opposed first and second sampling cavities rotates between fired faceplates defining flow passageways positioned to be alternatively in axial alignment with the first and second cavities. Silicon carbide inserts and liners composed of [alpha] silicon carbide are provided in the faceplates and in the sampling cavities to limit erosion while providing lubricity for a smooth and precise operation when used under harsh process conditions. 1 fig.

  18. [Biology and mechanobiology of the intervertebral disc].

    PubMed

    González Martínez, Emilio; García-Cosamalón, José; Cosamalón-Gan, Iván; Esteban Blanco, Marta; García-Suarez, Olivia; Vega, José A

    2017-01-24

    The intervertebral disc (IVD) is noted for its low cell content, and being the largest avascular structure of human body. The low amount of cells in the disc have to adapt to an anaerobic metabolism with low oxygen pressure and acidic pH. Apart from surviving in an adverse microenvironment, they are exposed to a high level of mechanical stress. The biological adaptation of cells to acidosis and hyperosmolarity conditions are regulated by mechanoproteins, which are responsible for converting a mechanical signal into a cellular response, thus modifying its gene expression. Mechanobiology helps us to better understand the pathophysiology of IVD and its potential biological repair.

  19. Area Minimizing Discs in Metric Spaces

    NASA Astrophysics Data System (ADS)

    Lytchak, Alexander; Wenger, Stefan

    2017-03-01

    We solve the classical problem of Plateau in the setting of proper metric spaces. Precisely, we prove that among all disc-type surfaces with prescribed Jordan boundary in a proper metric space there exists an area minimizing disc which moreover has a quasi-conformal parametrization. If the space supports a local quadratic isoperimetric inequality for curves we prove that such a solution is locally Hölder continuous in the interior and continuous up to the boundary. Our results generalize corresponding results of Douglas Radò and Morrey from the setting of Euclidean space and Riemannian manifolds to that of proper metric spaces.

  20. The effectiveness of percutaneous laser disc decompression for the prolapsed lumbar intervertebral disc

    NASA Astrophysics Data System (ADS)

    Mu, Ming Wei; Liu, Wei; Feng, Wei; Ma, Nan

    2009-07-01

    Objective: to investigate the role of associated factors in the effectiveness of laser treatment for prolapsed lumber intervertebral disc. Method: 302 prolapsed lumber intervertebral discs in 212 patients were treated with percutaneous laser disc decompression (PLDD). Patients were followed up by 12month, the associated factors which affecting the effectiveness of treatment, ie age, duration of illness were analyzed. Results: Punctual Success rate was 100%. After 12 month's follow up, 86% successful outcomes were obtained, in which 93% successful outcomes were obtained in patients less than 50 years old, 92% successful outcomes was obtained in the patients whose duration of illness less than 1 year.

  1. Intervertebral disc degeneration: evidence for two distinct phenotypes

    PubMed Central

    Adams, Michael A; Dolan, Patricia

    2012-01-01

    We review the evidence that there are two types of disc degeneration. ‘Endplate-driven’ disc degeneration involves endplate defects and inwards collapse of the annulus, has a high heritability, mostly affects discs in the upper lumbar and thoracic spine, often starts to develop before age 30 years, usually leads to moderate back pain, and is associated with compressive injuries such as a fall on the buttocks. ‘Annulus-driven’ disc degeneration involves a radial fissure and/or a disc prolapse, has a low heritability, mostly affects discs in the lower lumbar spine, develops progressively after age 30 years, usually leads to severe back pain and sciatica, and is associated with repetitive bending and lifting. The structural defects which initiate the two processes both act to decompress the disc nucleus, making it less likely that the other defect could occur subsequently, and in this sense the two disc degeneration phenotypes can be viewed as distinct. PMID:22881295

  2. Cost Utility Analysis of the Cervical Artificial Disc vs Fusion for the Treatment of 2-Level Symptomatic Degenerative Disc Disease: 5-Year Follow-up

    PubMed Central

    Yang, Zhuo; Nunley, Pierce; Stone, Marcus B.; Lee, Darrin; Kim, Kee D.

    2016-01-01

    BACKGROUND: The cervical total disc replacement (cTDR) was developed to treat cervical degenerative disc disease while preserving motion. OBJECTIVE: Cost-effectiveness of this intervention was established by looking at 2-year follow-up, and this update reevaluates our analysis over 5 years. METHODS: Data were derived from a randomized trial of 330 patients. Data from the 12-Item Short Form Health Survey were transformed into utilities by using the SF-6D algorithm. Costs were calculated by extracting diagnosis-related group codes and then applying 2014 Medicare reimbursement rates. A Markov model evaluated quality-adjusted life years (QALYs) for both treatment groups. Univariate and multivariate sensitivity analyses were conducted to test the stability of the model. The model adopted both societal and health system perspectives and applied a 3% annual discount rate. RESULTS: The cTDR costs $1687 more than anterior cervical discectomy and fusion (ACDF) over 5 years. In contrast, cTDR had $34 377 less productivity loss compared with ACDF. There was a significant difference in the return-to-work rate (81.6% compared with 65.4% for cTDR and ACDF, respectively; P = .029). From a societal perspective, the incremental cost-effective ratio (ICER) for cTDR was −$165 103 per QALY. From a health system perspective, the ICER for cTDR was $8518 per QALY. In the sensitivity analysis, the ICER for cTDR remained below the US willingness-to-pay threshold of $50 000 per QALY in all scenarios (−$225 816 per QALY to $22 071 per QALY). CONCLUSION: This study is the first to report the comparative cost-effectiveness of cTDR vs ACDF for 2-level degenerative disc disease at 5 years. The authors conclude that, because of the negative ICER, cTDR is the dominant modality. ABBREVIATIONS: ACDF, anterior cervical discectomy and fusion AWP, average wholesale price CE, cost-effectiveness CEA, cost-effectiveness analysis CPT, Current Procedural Terminology cTDR, cervical total disc

  3. Structural and Ultrastructural Analysis of the Cervical Discs of Young and Elderly Humans.

    PubMed

    Fontes, Ricardo Braganca de Vasconcellos; Baptista, Josemberg Silva; Rabbani, Said Rahnamaye; Traynelis, Vincent C; Liberti, Edson Aparecido

    2015-01-01

    Several studies describing the ultrastructure and extracellular matrix (ECM) of intervertebral discs (IVDs) involve animal models and specimens obtained from symptomatic individuals during surgery for degenerative disease or scoliosis, which may not necessarily correlate to changes secondary to normal aging in humans. These changes may also be segment-specific based on different load patterns throughout life. Our objective was to describe the ECM and collagen profile of cervical IVDs in young (G1 - <35 years) and elderly (G2 - >65 years) presumably-asymptomatic individuals. Thirty cervical discs per group were obtained during autopsies of presumably-asymptomatic individuals. IVDs were analyzed with MRI, a morphological grading scale, light microscopy, scanning electron microscopy (SEM) and immunohistochemistry (IHC) for collagen types I, II, III, IV, V, VI, IX and X. Macroscopic degenerative features such as loss of annulus-nucleus distinction and fissures were found in both groups and significantly more severe in G2 as expected. MRI could not detect all morphological changes when compared even with simple morphological inspection. The loose fibrocartilaginous G1 matrix was replaced by a denser ECM in G2 with predominantly cartilaginous characteristics, chondrocyte clusters and absent elastic fibers. SEM demonstrated persistence of an identifiable nucleus and Sharpey-type insertion of cervical annulus fibers even in highly-degenerated G2 specimens. All collagen types were detected in every disc sector except for collagen X, with the largest area stained by collagens II and IV. Collagen detection was significantly decreased in G2: although significant intradiscal differences were rare, changes may occur faster or earlier in the posterior annulus. These results demonstrate an extensive modification of the ECM with maintenance of basic ultrastructural features despite severe macroscopic degeneration. Collagen analysis supports there is not a "pathologic" collagen type

  4. Pitfalls in the diagnosis and management of Cushing's syndrome.

    PubMed

    Bansal, Vivek; El Asmar, Nadine; Selman, Warren R; Arafah, Baha M

    2015-02-01

    .g., malabsorption, celiac disease) and by the concurrent use of medications that interfere with its metabolism (e.g., inducers and inhibitors of the P450 enzyme system). In this review, the authors aim to review the pitfalls commonly encountered in the workup of patients suspected to have hypercortisolism. The optimal diagnosis and therapy for patients with Cushing's disease require the thorough and close coordination and involvement of all members of the management team.

  5. Geochemical databases: minding the pitfalls to avoid the pratfalls

    NASA Astrophysics Data System (ADS)

    Goldstein, S. L.; Hofmann, A. W.

    2011-12-01

    The field of geochemistry has been revolutionized in recent years by the advent of databases (PetDB, GEOROC, NAVDAT, etc). A decade ago, a geochemical synthesis required major time investments in order to compile relatively small amounts of fragmented data from large numbers of publications, Now virtually all of the published data on nearly any solid Earth topic can be downloaded to nearly any desktop computer with a few mouse clicks. Most solid Earth talks at international meetings show data compilations from these databases. Applications of the data are playing an increasingly important role in shaping our thinking about the Earth. They have changed some fundamental ideas about the compositional structure of the Earth (for example, showing that the Earth's "trace element depleted upper mantle" is not so depleted in trace elements). This abundance of riches also poses new risks. Until recently, important details associated with data publication (adequate metadata and quality control information) were given low priority, even in major journals. The online databases preserve whatever has been published, irrespective of quality. "Bad data" arises from many causes, here are a few. Some are associated with sample processing, including incomplete dissolution of refractory trace minerals, or inhomogeneous powders, or contamination of key elements during preparation (for example, this was a problem for lead when gasoline was leaded, and for niobium when tungsten-carbide mills were used to powder samples). Poor analytical quality is a continual problem (for example, when elemental abundances are at near background levels for an analytical method). Errors in published data tables (more common than you think) become bad data in the databases. The accepted values of interlaboratory standards change with time, while the published data based on old values stay the same. Thus the pitfalls associated with the new data accessibility are dangerous in the hands of the inexperienced

  6. Effects of tissue-engineered articular disc implants on the biomechanical loading of the human temporomandibular joint in a three-dimensional finite element model.

    PubMed

    Al-Sukhun, Jehad; Ashammakhi, Nureddin; Penttila, Heikki

    2007-07-01

    The purpose of this study was to evaluate biomechanical loading of the temporomandibular joint when using a biodegradable laminate implant to replace the articular disc and to test the hypothesis that the use of the implant reduces stress distribution in the condyle, implant, and glenoid fossa. A finite element model of a female human mandible, including the temporomandibular joint, which had two standard endosseous implants inserted bilaterally in the premolar region, was constructed from computed tomography scan images using a commercially available finite element software. The disc, condyle, and glenoid fossa were arbitrarily divided into five regions: the anterior, posterior, medial, lateral, and central. The disc was then replaced with a poly-L/DL-lactide biodegradable laminate. The finite element model was then used to predict principal and Von Mises stresses. The use of poly-L/DL-lactide implant resulted in remarkable reduction in Von Mises stresses (approximately threefold) in the anterior, central, and medial regions of the mandibular condyle in comparison with slight to moderate stress reductions in the corresponding regions of the implant and glenoid fossa. The mandibular condyle also demonstrated the largest total displacement in all directions followed by the implant and glenoid fossa. The use of an alloplastic implant such as the bioresorbable, poly-L/DL-lactide laminate to replace the articular disc reduces loading of the mandibular condyle rather than the implant and glenoid fossa. These findings lead to support the hypothesis that the mandibular condyle more likely functions as a shock absorber than the disc. The use of bioresorbable laminate implants might prove an efficient technique to replace the articular disc and promote normal function of the temporomandibular joint.

  7. Interactive Optical Disc Systems: Part 1: Analog Storage.

    ERIC Educational Resources Information Center

    Hessler, David W.

    1984-01-01

    Details distinction between digital and analog data, advantages of analog storage, and optical disc use to store analog data. Configuration and potential of three levels of laser disc systems are explained. Selection of display devices for use with laser disc systems and accessing audio data are addressed. (Continued in next issue.) (EJS)

  8. 26 CFR 1.992-1 - Requirements of a DISC.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... election to be treated as a DISC be in effect for such year, as described in paragraph (e) of this section... stock. (e) Election in effect. In order for a corporation to be a DISC for a taxable year, an election... for purposes of § 1.992-2(e)(3) (relating to the termination of a DISC election if a corporation...

  9. Single implant tooth replacement.

    PubMed

    Briley, T F

    1998-01-01

    It has been shown that direct bone anchorage of dental implants will provide long-term predictability for single tooth implants and multi-unit implants. The function of implant-supported restoration is now routinely achieved. The real challenge facing the restorative dentist and laboratory technician is to achieve optimal aesthetics. The learning objective of this article is to review the prosthodontic procedures essential to maximizing natural aesthetics in implant supported restorations. It will provide a review of master impression techniques, prepable titanium abutments and designing the cement on restoration. Particular emphasis is directed to the soft tissue model from which a series of sequenced techniques can be followed to achieve optimal aesthetics. Analysis of the implant alignment with regard to the neighboring teeth will result in having to make a choice of which prepable abutment will maximize the aesthetic result. The following case outlines how to replace a single missing tooth using an externally hexed implant system and a prefabricated titanium abutment on a 26-year-old male patient.

  10. Reuse, replace, recycle

    PubMed Central

    McMurray, Michael A.; Thorner, Jeremy W.

    2015-01-01

    Septins are guanine nucleotide-binding proteins that form hetero-oligomeric complexes, which assemble into filaments and higher-order structures at sites of cell division and morphogenesis in eukaryotes. Dynamic changes in the organization of septin-containing structures occur concomitantly with progression through the mitotic cell cycle and during cell differentiation. Septins also undergo stage-specific post-translational modifications, which have been implicated in regulating their dynamics, in some cases via purported effects on septin turnover. In our recent study, the fate of two of the five septins expressed in mitotic cells of budding yeast (Saccharomyces cerevisiae) was tracked using two complementary fluorescence-based methods for pulse-chase analysis. During mitotic growth, previously-made molecules of both septins (Cdc10 and Cdc12) persisted through multiple successive divisions and were incorporated equivalently with newly synthesized molecules into hetero-oligomers and higher-order structures. Similarly, in cells undergoing meiosis and the developmental program of sporulation, pre-existing copies of Cdc10 were incorporated into new structures. In marked contrast, Cdc12 was irreversibly excluded from septin complexes and replaced by another septin, Spr3. Here, we discuss the broader implications of these results and related findings with regard to how septin dynamics is coordinated with the mitotic cell cycle and in the yeast life cycle, and how these observations may relate to control of the dynamics of other complex multi-subunit assemblies. PMID:19164941

  11. Prognosis of intervertebral disc loss from diagnosis of degenerative disc disease

    NASA Astrophysics Data System (ADS)

    Li, S.; Lin, A.; Tay, K.; Romano, W.; Osman, Said

    2015-03-01

    Degenerative Disc Disease (DDD) is one of the most common causes of low back pain, and is a major factor in limiting the quality of life of an individual usually as they enter older stages of life, the disc degeneration reduces the shock absorption available which in turn causes pain. Disc loss is one of the central processes in the pathogenesis of DDD. In this study, we investigated whether the image texture features quantified from magnetic resonance imaging (MRI) could be appropriate markers for diagnosis of DDD and prognosis of inter-vertebral disc loss. The main objective is to use simple image based biomarkers to perform prognosis of spinal diseases using non-invasive procedures. Our results from 65 subjects proved the higher success rates of the combination marker compared to the individual markers and in the future, we will extend the study to other spine regions to allow prognosis and diagnosis of DDD for a wider region.

  12. DISC-BASED IMMUNOASSAY MICROARRAYS. (R825433)

    EPA Science Inventory

    Microarray technology as applied to areas that include genomics, diagnostics, environmental, and drug discovery, is an interesting research topic for which different chip-based devices have been developed. As an alternative, we have explored the principle of compact disc-based...

  13. Eclipse Mapping: Astrotomography of Accretion Discs

    NASA Astrophysics Data System (ADS)

    Baptista, Raymundo

    The Eclipse Mapping Method is an indirect imaging technique that transforms the shape of the eclipse light curve into a map of the surface brightness distribution of the occulted regions. Three decades of application of this technique to the investigation of the structure, the spectrum and the time evolution of accretion discs around white dwarfs in cataclysmic variables have enriched our understanding of these accretion devices with a wealth of details such as (but not limited to) moving heating/cooling waves during outbursts in dwarf novae, tidally-induced spiral shocks of emitting gas with sub-Keplerian velocities, elliptical precessing discs associated to superhumps, and measurements of the radial run of the disc viscosity through the mapping of the disc flickering sources. This chapter reviews the principles of the method, discusses its performance, limitations, useful error propagation procedures, as well as highlights a selection of applications aimed at showing the possible scientific problems that have been and may be addresses with it.

  14. Disc valve for sampling erosive process streams

    DOEpatents

    Mrochek, J.E.; Dinsmore, S.R.; Chandler, E.W.

    1984-08-16

    This is a patent for a disc-type, four-port sampling valve for service with erosive high temperature process streams. Inserts and liners of ..cap alpha..-silicon carbide respectively, in the faceplates and in the sampling cavities, limit erosion while providing lubricity for a smooth and precise operation. 1 fig.

  15. Frictional Torque on a Rotating Disc

    ERIC Educational Resources Information Center

    Mungan, Carl E.

    2012-01-01

    Resistance to motion often includes a dry frictional term independent of the speed of an object and a fluid drag term varying linearly with speed in the viscous limit. (At higher speeds, quadratic drag can also occur.) Here, measurements are performed for an aluminium disc mounted on bearings that is given an initial twist and allowed to spin…

  16. Nonsurgical management of disc-interference disorders.

    PubMed

    Okeson, J P

    1991-01-01

    Disc-interference disorders are a group of intracapsular problems that make up one category of temporomandibular disorders. The dental profession's understanding of these disorders has changed greatly in recent years. This article reviews current concepts regarding the diagnosis and management of these disorders as revealed through recent clinical studies.

  17. Extradural cavernous haemangioma simulating a disc protrusion.

    PubMed

    Slavotinek, J P; Fowler, S; Sage, M R; Brophy, B P

    1999-02-01

    Cavernous haemangiomas confined to the epidural space are rare and are therefore infrequently considered in the differential diagnosis of spinal epidural masses. In order to draw attention to this diagnosis, a case in which an epidural cavernous haemangioma simulates a lateral/foraminal disc protrusion is presented.

  18. Evolution of gas in debris discs

    NASA Astrophysics Data System (ADS)

    Kral, Quentin; Wyatt, Mark; Pringle, Jim

    2015-12-01

    A non negligible quantity of gas has been discovered in an increasing number of debris disc systems. ALMA high sensitivity and high resolution is changing our perception of the gaseous component of debris discs as CO is discovered in systems where it should be rapidly photodissociated. It implies that there is a replenishment mechanism and that the observed gas is secondary. Past missions such as Herschel probed the atomic part of the gas through O I and C II emission lines. Gas science in debris discs is still in its infancy, and these new observations raise a handful of questions concerning the mechanisms to create the gas and about its evolution in the planetary system when it is released. The latter question will be addressed in this talk as a self-consistent gas evolution scenario is proposed and is compared to observations for the peculiar case of β Pictoris.Our model proposes that carbon and oxygen within debris discs are created due to photodissociation of CO which is itself created from the debris disc dust (due to grain-grain collisions or photodesorption). The evolution of the carbon atoms is modelled as viscous spreading, with viscosity parameterised using an α model. The temperature, ionisation fraction and population levels of carbon are followed with a PDR model called Cloudy, which is coupled to the dynamical viscous α model. Only carbon gets ionised due to its lower ionisation potential than oxygen. The carbon gas disc can end up with a high ionisation fraction due to strong FUV radiation field. A high ionisation fraction means that the magnetorotational instability (MRI) is very active, so that α is very high. Gas density profiles can be worked out for different input parameters such as the α value, the CO input rate, the location of the input and the incoming radiation field. Observability predictions can be made for future observations, and our model is tested on β Pictoris observations. This new gas evolution model fits the carbon and CO

  19. Scaling from discs to pleated devices.

    PubMed

    Giglia, Sal; Yavorsky, David

    2007-01-01

    Membrane discs offer a convenient format for evaluating membrane performance in normal flow filtration. However, while pleated devices of different sizes tend to scale in close proportion to their contained areas, they do not necessarily scale in direct proportion from flat discs. The objectives of this study are to quantify differences in performance among sterilizing-grade membrane devices as a function of device type and size, to develop an understanding of the factors that affect device scalability, and to develop a mathematical model to predict a cartridge-to-disc scalability factor based on membrane properties and porous support properties and dimensions. Measured and predicted normalized water permeability scalability factors for seven types of pleated cartridges, including 0.1-micro and 0.2-micro rated PES, and 0.2-micro rated polyvinylidene fluoride (PVDF) sterilizing-grade filters in nominal 1-inch to 5-inch lengths, were determined. The results of this study indicate that pleated cartridge performance can be closely predicted based on 47-mm disc performance provided that a number of measured device parameters are properly accounted for, most importantly parasitic pressure losses in the filter device and plumbing connections, intrinsic membrane variability, true effective device filtration area, and the hydraulic properties of all porous support materials. Throughput scalability factors (discs to devices) tend to converge towards unity, especially for highly plugging streams. As the membrane fouls, the resistance through the membrane dominates other resistances, so the flux scales more linearly with membrane area and the overall scaling factor becomes close to one. The results of throughput tests on seven different cartridge types and five different challenge streams (with widely varying fouling characteristics) show that most of the throughput scaling factors were within +/-10% of 1.0. As part of this study, the effects of pressure and temperature were

  20. Enhancement of Overgrowth by Gene Interactions in Lethal(2)giant Discs Imaginal Discs from Drosophila Melanogaster

    PubMed Central

    Buratovich, M. A.; Bryant, P. J.

    1997-01-01

    Recessive lethal mutations of the lethal(2)giant discs (l(2)gd) and lethal(2)fat (l(2)ft) loci of Drosophila melanogaster cause imaginal disc hyperplasia during a prolonged larval stage. Imaginal discs from l(2)ft l(2)gd or Gl(2)gd double homozygotes show more extensive overgrowth than in either single homozygote, and double homozygous l(2)ft l(2)gd mitotic clones in adult flies show much more overgrowth than is seen in clones homozygous for either l(2)gd or l(2)ft alone. dachsous (ds) also acts as an enhancer of l(2)gd, producing dramatically overgrown discs and causing failure to pupariate in double homozygotes. The comb gap (cg) mutation, which also interacts with ds, greatly enhances the tendency of imaginal discs from l(2)gd larvae to duplicate as they overgrow. If l(2)gd homozygotes are made heterozygous for l(2)ft, then several discs duplicate, indicating that l(2)ft acts as a dominant enhancer of l(2)gd. l(2)ft also acts as a dominant enhancer of l(2)gd, and conversely l(2)gd acts as a dominant modifier of l(2)ft. The enhancement of overgrowth caused by various mutant combinations is accompanied by changes in expression of Decapentaplegic and Wingless. These results show that tumor suppressor genes act in combination to control cell proliferation, and that tissue hyperplasia can be associated with ectopic expression of genes involved in pattern formation. PMID:9335602

  1. Role of Cytokines in Intervertebral Disc Degeneration: Pain and Disc-content

    PubMed Central

    Risbud, Makarand V.; Shapiro, Irving. M

    2014-01-01

    Degeneration of the intervertebral disc is the major contributor to back/neck and radicular pain. It is characterized by an elevation in levels of the inflammatory cytokines tumor necrosis factor (TNF)-α, interleukin (IL)-1 α/β, IL-6 and IL-17 secreted by the disc cells themselves; these cytokines promote matrix degradation, chemokine production and changes in cell phenotype. The resulting imbalance between catabolic and anabolic responses leads to degeneration, as well as herniation and radicular pain. Release of chemokines from degenerating discs promote infiltration and activation of T and B cells, macrophages, neutrophils, and mast cells further amplifying the inflammatory cascade. Immunocyte migration into the disc is accompanied by the appearance of microvasculature and nerve fibers arising from the dorsal root ganglion (DRG). In this inflammatory milieu, neurogenic factors in particular nerve growth factor (NGF) and brain-derive neurotrophic factor (BDNF) generated by disc and immune cells induce expression of pain associated cation channels in DRGs. Depolarization of these channels is likely to promote discogenic and radicular pain and reinforce the cytokine-mediated degenerative cascade. Taken together, the enhanced understanding of the contribution of cytokines and immune cells to catabolic and nociceptive processes provide new targets for treating symptomatic disc disease. PMID:24166242

  2. Influence of blade profile of disc cutter on numerical simulation of the disc slitting process

    NASA Astrophysics Data System (ADS)

    Zeng, J.; Lu, J. B.; Yan, Q. S.; Li, S.

    2015-03-01

    The disc slitting machining experiments for electrical steel sheet were conducted to investigate the wear process of carbide alloy disc cutter and the slitting quality in the disc slitting process, and the blade contour shape of disc cutter in different slitting distance was measured by the surface profiler. A DEFORM-2D model, where the real blade profile or arc fitting profile was used as the blade contour of the cutter, was built to simulate the disc slitting process. Results show that the blade wear of disc cutter increases. The blade wear presents uneven in the side surface and cylindrical surface of the cutter, and the side wear is more serious with the increase of the slitting distance of electrical steel sheet. As the blade wear increases, the height of the rollover increases gradually, the height of the shear area increases at first and then decreases, but the height of the fracture area decreases at first and then increases. Compared with the arc fitting profile, the simulation surface morphology using the real blade profile is in good agreement with the experimental result. The variation of blade profile can change the distribution of the hydrostatic stress of sheet metal and the occurring and propagating of the crack, and the maximum hydrostatic stress can be used to estimate the change tendency of the fracture area.

  3. Differentiation of glaucomatous optic discs with different appearances using optic disc topography parameters: The Glaucoma Stereo Analysis Study

    PubMed Central

    Tanito, Masaki; Nitta, Koji; Katai, Maki; Kitaoka, Yasushi; Yokoyama, Yu; Omodaka, Kazuko; Nakazawa, Toru

    2017-01-01

    The Glaucoma Stereo Analysis Study (GSAS) is a multicenter collaborative study of the characteristics of glaucomatous optic disc morphology using a stereo fundus camera. Using GSAS dataset, the formulas for predicting different glaucomatous optic disc appearances were established. The GSAS dataset containing three-dimensionally-analyzed optic disc topographic parameters from 187 eyes with primary open-angle glaucoma was assessed with discrimination analyses to obtain formulas predictive of glaucomatous optic disc appearances: focal ischemic (FI); generalized enlargement (GE), myopic glaucomatous (MY), and senile sclerotic (SS). Using 38 optic disc parameters-substituted discrimination analyses with a stepwise forward-selection method, six parameters (temporal and nasal rim-disc ratios, mean cup depth, height variation contour, disc tilt angle, and rim decentering absolute) were selected into the formulas. The area under the receiver operating characteristic curves for predicting the four disc types with established formulas were 0.88, 0.91, 0.93, and 0.86 for FI, MY, SS, and GE, respectively. Age, visual acuity, refractive error, glaucoma (normal or high-tension glaucoma), and baseline intraocular pressure differed significantly among the four optic disc types, suggesting the appearances represent different clinical glaucoma phenotypes. Using six optic disc topographic parameters obtained by stereo fundus camera, the GSAS classification formulas predicted and quantified each component of different optic disc appearances in each eye and provided a novel parameter to describe glaucomatous optic disc characteristics. PMID:28178303

  4. Diagnostic pitfalls associated with a large true posterior communicating artery aneurysm: a case report.

    PubMed

    Nagatani, Kimihiro; Otani, Naoki; Seno, Soichiro; Takeuchi, Satoru; Wada, Kojiro; Mori, Kentaro

    2013-10-01

    True posterior communicating artery (PCoA) aneurysm is an aneurysm that originates from the PCoA, and large or giant true PCoA aneurysms are rare. We report a case of a large true PCoA aneurysm successfully clipped after anterior clinoidectomy and discuss the diagnostic pitfalls associated with this rare clinical entity.

  5. The Pitfalls of Mobile Devices in Learning: A Different View and Implications for Pedagogical Design

    ERIC Educational Resources Information Center

    Ting, Yu-Liang

    2012-01-01

    Studies have been devoted to the design, implementation, and evaluation of mobile learning in practice. A common issue among students' responses toward this type of learning concerns the pitfalls of mobile devices, including small screen, limited input options, and low computational power. As a result, mobile devices are not always perceived by…

  6. Two new planthopper species (Hemiptera, Fulgoroidea, Caliscelidae) collected in pitfall traps in Zambia.

    PubMed

    Chmurova, Lucia; Webb, Michael D

    2016-08-22

    Two new species of planthoppers in the family Caliscelidae (Hemiptera: Fulgoroidea) are described from Zambia, i.e., Afronaso spinosa sp. n. and Calampocus zambiaensis sp. n. All specimens are flightless males and nearly all were collected from baited pitfall traps (except for one specimen collected from a yellow pan trap), suggesting that they live near to or on the ground.

  7. The Pitfalls of Valenced Labels and the Benefits of Properly Calibrated Psychological Flexibility

    ERIC Educational Resources Information Center

    McNulty, James K.; Fincham, Frank D.

    2012-01-01

    Replies to comments by Sonja Lyubomirsky (see record 2012-27130-008), Riva Guiseppe (see record 2012-27130-009), and Alan S. Waterman (see record 2012-27130-010) on the original article by McNulty and Fincham (see record 2011-15476-001) regarding the pitfalls of valenced labels and the benefits of properly calibrated psychological flexibility.

  8. Evaluation of pitfall trapping in northwestern forests: trap arrays with drift fences

    USGS Publications Warehouse

    Bury, R. Bruce; Corn, Paul Stephen

    1987-01-01

    We operated pitfall arrays with 5-m drift fences at 30 stands in western Oregon and Washington for 180 days. Pitfall arrays had a pronounced removal effect on small mammals (but not on the herpetofauna) during the 1st 60 days of trapping. Conventional short (10-day) trapping periods were only adequate to detect the most common mammals. About 60 days were needed to compile a relatively complete species list (>85% of species captured) at each site. Reptiles were caught almost exclusively in the summer; amphibian captures were correlated with increased precipitation in the fall. Short (2.5-m) drift fences were less effective than the standard length of 5 m. Funnel traps captured few forest vertebrates. Pitfalls captured more insectivorous mammals than did snap traps, but snap traps were more effective for a few cricetid rodents. Pitfall arrays are adaptable to many habitats and can help assess the presence of small vertebrates, such as shrews and amphibians, that are undersampled by other techniques.

  9. Analysis of Factors Enhancing Pitfall in Research and Teaching of the Nigerian University System

    ERIC Educational Resources Information Center

    Ahmed, Tafida; Umar, Kasim; Paul, Chima

    2015-01-01

    The paper analyses factors enhancing pitfall in research and teaching in the Nigerian university system. Using data generated from secondary sources, it was found that so many factors are responsible for the constant decay in teaching and research in the Nigerian universities. The paper however found from literature that the high rate of pitfalls…

  10. Pitfalls and Promises: The Use of Secondary Data Analysis in Educational Research

    ERIC Educational Resources Information Center

    Smith, Emma

    2008-01-01

    This paper considers the use of secondary data analysis in educational research. It addresses some of the promises and potential pitfalls that influence its use and explores a possible role for the secondary analysis of numeric data in the "new" political arithmetic tradition of social research. Secondary data analysis is a relatively under-used…

  11. Empathy and Social-Emotional Learning: Pitfalls and Touchstones for School-Based Programs

    ERIC Educational Resources Information Center

    Maxwell, Bruce; DesRoches, Sarah

    2010-01-01

    This chapter identifies three common pitfalls in the use of the concept of empathy in formal social-emotional learning interventions: (1) not distinguishing between affective and cognitive empathy ("equivocation"); (2) overestimating the role of the imagination in empathizing ("Piaget's fallacy"); and (3) not accommodating the developmental and…

  12. Benefits and Pitfalls: Simple Guidelines for the Use of Social Networking Tools in K-12 Education

    ERIC Educational Resources Information Center

    Huffman, Stephanie

    2013-01-01

    The article will outline a framework for the use of social networking tools in K-12 education framed around four thought provoking questions: 1) what are the benefits and pitfalls of using social networking tools in P-12 education, 2) how do we plan effectively for the use of social networking tool, 3) what role does professional development play…

  13. The Effects of "Math Pathways and Pitfalls" on Students' Mathematics Achievement: National Science Foundation Final Report

    ERIC Educational Resources Information Center

    Heller, Joan I.; Curtis, Deborah A.; Rabe-Hesketh, Sophia; Verboncoeur, Carol J.

    2007-01-01

    This study was designed to assess the impact of "Mathematics Pathways and Pitfalls" ("MPP") on the mathematics that second-, fourth-, and sixth-grade students learn. The specific research questions that were addressed are: (a) What is the impact of "MPP" on students' knowledge of the mathematics topics addressed,…

  14. Antenna Controller Replacement Software

    NASA Technical Reports Server (NTRS)

    Chao, Roger Y.; Morgan, Scott C.; Strain, Martha M.; Rockwell, Stephen T.; Shimizu, Kenneth J.; Tehrani, Barzia J.; Kwok, Jaclyn H.; Tuazon-Wong, Michelle; Valtier, Henry; Nalbandi, Reza; Wert, Michael; Leung, Patrick

    2010-01-01

    The Antenna Controller Replacement (ACR) software accurately points and monitors the Deep Space Network (DSN) 70-m and 34-m high-efficiency (HEF) ground-based antennas that are used to track primarily spacecraft and, periodically, celestial targets. To track a spacecraft, or other targets, the antenna must be accurately pointed at the spacecraft, which can be very far away with very weak signals. ACR s conical scanning capability collects the signal in a circular pattern around the target, calculates the location of the strongest signal, and adjusts the antenna pointing to point directly at the spacecraft. A real-time, closed-loop servo control algorithm performed every 0.02 second allows accurate positioning of the antenna in order to track these distant spacecraft. Additionally, this advanced servo control algorithm provides better antenna pointing performance in windy conditions. The ACR software provides high-level commands that provide a very easy user interface for the DSN operator. The operator only needs to enter two commands to start the antenna and subreflector, and Master Equatorial tracking. The most accurate antenna pointing is accomplished by aligning the antenna to the Master Equatorial, which because of its small size and sheltered location, has the most stable pointing. The antenna has hundreds of digital and analog monitor points. The ACR software provides compact displays to summarize the status of the antenna, subreflector, and the Master Equatorial. The ACR software has two major functions. First, it performs all of the steps required to accurately point the antenna (and subreflector and Master Equatorial) at the spacecraft (or celestial target). This involves controlling the antenna/ subreflector/Master-Equatorial hardware, initiating and monitoring the correct sequence of operations, calculating the position of the spacecraft relative to the antenna, executing the real-time servo control algorithm to maintain the correct position, and

  15. Creep Behavior of Anisotropic Functionally Graded Rotating Discs

    NASA Astrophysics Data System (ADS)

    Rattan, Minto; Chamoli, Neeraj; Singh, Satya Bir; Gupta, Nishi

    2013-08-01

    The creep behavior of an anisotropic rotating disc of functionally gradient material (FGM) has been investigated in the present study using Hill's yield criteria and the creep behavior in this case is assumed to follow Sherby's constitutive model. The stress and strain rate distributions are calculated for disc having different types of anisotropy and the results obtained are compared graphically. It is concluded that the anisotropy of the material has a significant effect on the creep behavior of the FGM disc. It is also observed that the FGM disc shows better creep behavior than the non-FGM disc.

  16. Using your shoulder after replacement surgery

    MedlinePlus

    Joint replacement surgery - using your shoulder; Shoulder replacement surgery - after ... You have had shoulder replacement surgery to replace the bones of your shoulder joint with artificial parts. The parts include a stem made of metal and a ...

  17. On pitfalls in the construction of family-based models of population growth: a note.

    PubMed

    Kondo, H

    1986-04-01

    Recently, several attempts have been made to construct an economic theory of population based on a formal theory of the family of the type developed by Becker in 1981, but there are serious limitations in all such efforts. The typical family's problem may have no solution, even with a well-behaved concave utility function. Moreover, even when the family's maximum problem has a unique solution, the phase diagram for the stock of capital may contain no steady state other than the origin. Finally, even when there exists a nontrivial steady state for the stock of capital, the community nevertheless may be destined for extinction. The first of these pitfalls concerns the internal consistency of the models, while the second and third concern the compatibility of the models with some gross facts of life. The pitfalls can be avoided, within the Becker framework by suitably restricting the family's utility and production functions, but the restrictions required are severe. This paper shows that, alternatively, the pitfalls sometimes can be avoided by going slightly outside the Becker framework, specifically, by modifying the typical family's budget constraint to allow explicitly for the cost of raising children. In particular, it is shown that, by this means, the pitfalls can be avoided even when the famil's utility function is log-linear, the example adduced by Kemp et al. In 1984 to demonstrate the existence of pitfalls. More precisely, it is shown that the family's maximum problem has a unique solution; that nontrival steady state exists; that, even if the steady state is locally unstable, the optimal trajectory tends neither to zero nor to infinity but to a 2-period limit cycle; and that survival is possible with quite general production functions. Thus, the end product is a logically consistent and reasonable model of economic development, with both population growth and capital accumulation firmly rooted in life-cycle family planning.

  18. Educating My Replacement

    NASA Astrophysics Data System (ADS)

    Tarter, Jill

    , in partnership with the dedicated teachers out there, I think I can help promote the critical thinking skills and scientific literacy of the next generation of voters. Hopefully, I can also help train my replacement to be a better scientist, capable of seizing all the opportunities generated by advances in technology and our improved understanding of the universe to craft search strategies with greater probability of success than those I have initiated.

  19. Burn prevention mechanisms and outcomes: pitfalls, failures and successes.

    PubMed

    Atiyeh, Bishara S; Costagliola, Michel; Hayek, Shady N

    2009-03-01

    -risk groups. Depending on the population of the country, burns prevention could be a national programme. This can ensure sufficient funds are available and lead to proper coordination of district, regional, and tertiary care centres. It could also provide for compulsory reporting of all burn admissions to a central registry, and these data could be used to evaluate strategies and prevention programmes that should be directed at behavioural and environmental changes which can be easily adopted into lifestyle. Particularly in LMICs, the emphasis in burn prevention should be by advocating change from harmful cultural practices. This needs to be done with care and sensitivity. The present review is a summary of what has already been accomplished in terms of burn prevention highlighting some of the successes but above all the numerous pitfalls and failures. Recognizing these failures is the first step towards development of more effective burn prevention strategies particularly in LMICs in which burn injury remains endemic and associated with a high mortality rate. Burn prevention is not easy, but easy or not, we have no options; burns must be prevented.

  20. Dipper discs not inclined towards edge-on orbits

    NASA Astrophysics Data System (ADS)

    Ansdell, M.; Gaidos, E.; Williams, J. P.; Kennedy, G.; Wyatt, M. C.; LaCourse, D. M.; Jacobs, T. L.; Mann, A. W.

    2016-10-01

    The so-called dipper stars host circumstellar discs and have optical and infrared light curves that exhibit quasi-periodic or aperiodic dimming events consistent with extinction by transiting dusty structures orbiting in the inner disc. Most of the proposed mechanisms explaining the dips - i.e. occulting disc warps, vortices, and forming planetesimals - assume nearly edge-on viewing geometries. However, our analysis of the three known dippers with publicly available resolved sub-mm data reveals discs with a range of inclinations, most notably the face-on transition disc J1604-2130 (EPIC 204638512). This suggests that nearly edge-on viewing geometries are not a defining characteristic of the dippers and that additional models should be explored. If confirmed by further observations of more dippers, this would point to inner disc processes that regularly produce dusty structures far above the outer disc mid-plane in regions relevant to planet formation.

  1. [Ascending aorta replacement late after aortic valve replacement].

    PubMed

    Hayashi, Yasunari; Ito, Toshiaki; Maekawa, Atsuo; Sawaki, Sadanari; Fujii, Genyo; Hoshino, Satoshi; Tokoro, Masayoshi; Yanagisawa, Junji

    2013-07-01

    Replacement of the asceding aorta is indicated in patients undergoing aortic valve replacement( AVR), if the diameter of the ascending aorta is greater than 5.0 cm. If the diameter of the asceding aorta is from 4.0 to 5.0 cm, it was arguable whether replacement of the ascending aorta should be performed. Nine patients who underwent reoperative ascending aorta replacement after AVR were reviewed retrospectively. Reoperation on the asending aorta replacement was performed 11.8±7.2 years (range 1y5m~23y3m) after AVR. Mean patient age was 69.9±6.3 (range 60~81). In 2 cases, reoperations were performed early year after AVR. Although ascending aorta was dilated at the 1st operation, replacement wasn't performed for the age and minimally invasive cardiac surgery (MICS). In 3 cases, reoperations were performed more than 10 years later. On these cases, ascending aorta aneurysm and dissection occurred with no pain and were pointed out by computed tomography(CT) or ultrasonic cardiogram(UCG). We think that patients with dilatation of the ascending aorta should undergo AVR and aorta replacement at the 1st operation regardness of age. It is important that patients who underwent AVR should undergo a regular checkup on the ascending aorta.

  2. The avian intervertebral disc arises from rostral sclerotome and lacks a nucleus pulposus: Implications for evolution of the vertebrate disc

    PubMed Central

    Bruggeman, Bradley J.; Maier, Jennifer A.; Mohiuddin, Yasmin S.; Powers, Rae; Lo, YinTing; Guimarães-Camboa, Nuno; Evans, Sylvia M.; Harfe, Brian D.

    2012-01-01

    Deterioration of the intervertebral discs is an unfortunate consequence of aging. The intervertebral disc in mammals is composed of three parts: a jelly-like center called the nucleus pulposus, the cartilaginous annulus fibrosus and anterior and posterior endplates that attach the discs to vertebrae. In order to understand the origin of the disc, we have investigated the intervertebral region of chickens. Surprisingly, our comparison of mouse and chicken discs revealed that chicken discs lack nuclei pulposi. In addition, the notochord, which in mice forms nuclei pulposi, was found to persist as a rod-like structure and express Shh throughout chicken embryogenesis. Our fate mapping data indicates that cells originating from the rostral half of each somite are responsible for forming the avian disc while cells in the caudal region of each somite form vertebrae. A histological analysis of mammalian and non-mammalian organisms suggests that nuclei pulposi are only present in mammals. PMID:22354863

  3. Evaluation of an In Situ Gelable and Injectable Hydrogel Treatment to Preserve Human Disc Mechanical Function Undergoing Physiologic Cyclic Loading Followed by Hydrated Recovery.

    PubMed

    Showalter, Brent L; Elliott, Dawn M; Chen, Weiliam; Malhotra, Neil R

    2015-08-01

    Despite the prevalence of disc degeneration and its contributions to low back problems, many current treatments are palliative only and ultimately fail. To address this, nucleus pulposus replacements are under development. Previous work on an injectable hydrogel nucleus pulposus replacement composed of n-carboxyethyl chitosan, oxidized dextran, and teleostean has shown that it has properties similar to native nucleus pulposus, can restore compressive range of motion in ovine discs, is biocompatible, and promotes cell proliferation. The objective of this study was to determine if the hydrogel implant will be contained and if it will restore mechanics in human discs undergoing physiologic cyclic compressive loading. Fourteen human lumbar spine segments were tested using physiologic cyclic compressive loading while intact, following nucleotomy, and again following treatment of injecting either phosphate buffered saline (PBS) (sham, n = 7) or hydrogel (implant, n = 7). In each compressive test, mechanical parameters were measured immediately before and after 10,000 cycles of compressive loading and following a period of hydrated recovery. The hydrogel implant was not ejected from the disc during 10,000 cycles of physiological compression testing and appeared undamaged when discs were bisected following all mechanical tests. For sham samples, creep during cyclic loading increased (+15%) from creep during nucleotomy testing, while for implant samples creep strain decreased (-3%) toward normal. There was no difference in compressive modulus or compressive strains between implant and sham samples. These findings demonstrate that the implant interdigitates with the nucleus pulposus, preventing its expulsion during 10,000 cycles of compressive loading and preserves disc creep within human L5-S1 discs. This and previous studies provide a solid foundation for continuing to evaluate the efficacy of the hydrogel implant.

  4. Genipin-crosslinked fibrin hydrogels as a potential adhesive to augment intervertebral disc annulus repair.

    PubMed

    Schek, R M; Michalek, A J; Iatridis, J C

    2011-04-18

    Treatment of damaged intervertebral discs is a significant clinical problem and, despite advances in the repair and replacement of the nucleus pulposus, there are few effective strategies to restore defects in the annulus fibrosus. An annular repair material should meet three specifications: have a modulus similar to the native annulus tissue, support the growth of disc cells, and maintain adhesion to tissue under physiological strain levels. We hypothesized that a genipin crosslinked fibrin gel could meet these requirements. Our mechanical results showed that genipin crosslinked fibrin gels could be created with a modulus in the range of native annular tissue. We also demonstrated that this material is compatible with the in vitro growth of human disc cells, when genipin:fibrin ratios were 0.25:1 or less, although cell proliferation was slower and cell morphology more rounded than for fibrin alone. Finally, lap tests were performed to evaluate adhesion between fibrin gels and pieces of annular tissue. Specimens created without genipin had poor handling properties and readily delaminated, while genipin crosslinked fibrin gels remained adhered to the tissue pieces at strains exceeding physiological levels and failed at 15-30%. This study demonstrated that genipin crosslinked fibrin gels show promise as a gap-filling adhesive biomaterial with tunable material properties, yet the slow cell proliferation suggests this biomaterial may be best suited as a sealant for small annulus fibrosus defects or as an adhesive to augment large annulus repairs. Future studies will evaluate degradation rate, fatigue behaviors, and long-term biocompatibility.

  5. Hall magneto-hydrodynamics in protoplanetary discs

    NASA Astrophysics Data System (ADS)

    Béthune, W.; Lesur, G.; Ferreira, J.

    2016-12-01

    Protoplanetary discs exhibit large-scale, organised structures. Because they are dense and cold, they should be weakly ionized, and hence concerned by non-ideal plasma effects, such as the Hall effect. We perform numerical simulations of non-stratified Keplerian discs, in the non-ideal magnetohydrodynamic framework. We show that the Hall effect causes self-organisation through three distinct stages. A weak Hall effect enhances turbulent transport. At intermediate strength, it produces magnetized vortices. A strong Hall effect generates axisymmetric zonal flows. These structures may trap dust particles, and thus influence planetary formation. The transport of angular momentum is quenched in the organised state, impugning the relevance of magneto-rotational turbulence as a driving mechanism of accretion in Hall dominated regions.

  6. Grand Challenges in Protoplanetary Disc Modelling

    NASA Astrophysics Data System (ADS)

    Haworth, Thomas J.; Ilee, John D.; Forgan, Duncan H.; Facchini, Stefano; Price, Daniel J.; Boneberg, Dominika M.; Booth, Richard A.; Clarke, Cathie J.; Gonzalez, Jean-François; Hutchison, Mark A.; Kamp, Inga; Laibe, Guillaume; Lyra, Wladimir; Meru, Farzana; Mohanty, Subhanjoy; Panić, Olja; Rice, Ken; Suzuki, Takeru; Teague, Richard; Walsh, Catherine; Woitke, Peter; Community authors

    2016-10-01

    The Protoplanetary Discussions conference-held in Edinburgh, UK, from 2016 March 7th-11th-included several open sessions led by participants. This paper reports on the discussions collectively concerned with the multi-physics modelling of protoplanetary discs, including the self-consistent calculation of gas and dust dynamics, radiative transfer, and chemistry. After a short introduction to each of these disciplines in isolation, we identify a series of burning questions and grand challenges associated with their continuing development and integration. We then discuss potential pathways towards solving these challenges, grouped by strategical, technical, and collaborative developments. This paper is not intended to be a review, but rather to motivate and direct future research and collaboration across typically distinct fields based on community-driven input, to encourage further progress in our understanding of circumstellar and protoplanetary discs.

  7. Thalamic Pain Misdiagnosed as Cervical Disc Herniation.

    PubMed

    Lim, Tae Ha; Choi, Soo Il; Yoo, Jee In; Choi, Young Soon; Lim, Young Su; Sang, Bo Hyun; Bang, Yun Sic; Kim, Young Uk

    2016-04-01

    Thalamic pain is a primary cause of central post-stroke pain (CPSP). Clinical symptoms vary depending on the location of the infarction and frequently accompany several pain symptoms. Therefore, correct diagnosis and proper examination are not easy. We report a case of CPSP due to a left acute thalamic infarction with central disc protrusion at C5-6. A 45-year-old-male patient experiencing a tingling sensation in his right arm was referred to our pain clinic under the diagnosis of cervical disc herniation. This patient also complained of right cramp-like abdominal pain. After further evaluations, he was diagnosed with an acute thalamic infarction. Therefore detailed history taking should be performed and examiners should always be aware of other symptoms that could suggest a more dangerous disease.

  8. Inflammation in intervertebral disc degeneration and regeneration

    PubMed Central

    Molinos, Maria; Almeida, Catarina R.; Caldeira, Joana; Cunha, Carla; Gonçalves, Raquel M.; Barbosa, Mário A.

    2015-01-01

    Intervertebral disc (IVD) degeneration is one of the major causes of low back pain, a problem with a heavy economic burden, which has been increasing in prevalence as populations age. Deeper knowledge of the complex spatial and temporal orchestration of cellular interactions and extracellular matrix remodelling is critical to improve current IVD therapies, which have so far proved unsatisfactory. Inflammation has been correlated with degenerative disc disease but its role in discogenic pain and hernia regression remains controversial. The inflammatory response may be involved in the onset of disease, but it is also crucial in maintaining tissue homeostasis. Furthermore, if properly balanced it may contribute to tissue repair/regeneration as has already been demonstrated in other tissues. In this review, we focus on how inflammation has been associated with IVD degeneration by describing observational and in vitro studies as well as in vivo animal models. Finally, we provide an overview of IVD regenerative therapies that target key inflammatory players. PMID:25673296

  9. Vertical cup/disc ratio in relation to optic disc size: its value in the assessment of the glaucoma suspect

    PubMed Central

    Garway-Heath, D.; Ruben, S.; Viswanathan, A.; Hitchings, R.

    1998-01-01

    AIMS—The vertical cup/disc ratio (CDR) has long been used in the assessment of the glaucoma suspect, though the wide range of CDR values in the normal population limits its use. Cup size is related physiologically to disc size and pathologically to glaucomatous damage. Disc size can be measured at the slit lamp as the vertical disc diameter (DD). The ability of the CDR, in relation to DD, to identify glaucomatous optic discs was investigated.
METHODS—88 normal, 53 early glaucoma, and 59 ocular hypertensive subjects underwent stereoscopic optic disc photography and clinical biometry. Photographs were analysed in a masked fashion by computer assisted planimetry. The relation between vertical cup diameter and DD was explored by linear regression, and expressed in terms of CDR. The upper limit of normal was defined by the 95% prediction intervals of this regression (method 1) and by the upper 97.5 percentile for CDR (method 2). The sensitivity and specificity of CDR to identify an optic disc as glaucomatous was tested with these disc size dependent and disc size independent cut offs in small, medium, and large discs.
RESULTS—The CDR was related to DD by the equation CDR = (−1.31 + (1.194 × DD))/DD. The sensitivity in small, medium, and large discs was 80%, 60%, and 38% respectively for method 1 and 33%, 67%, and 63% respectively for method 2. Specificity was 98.9% (method 1) and 97.7% (method 2).
CONCLUSIONS—The CDR, relative to disc size, is useful clinically, especially to assist in identifying small glaucomatous discs.

 Keywords: cup/disc ratio; glaucoma; imaging PMID:9924296

  10. Minimally invasive photopolymerization in intervertebral disc tissue cavities

    NASA Astrophysics Data System (ADS)

    Schmocker, Andreas M.; Khoushabi, Azadeh; Gantenbein-Ritter, Benjamin; Chan, Samantha; Bonél, Harald Marcel; Bourban, Pierre-Etienne; Mânson, Jan Anders; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe

    2014-03-01

    Photopolymerized hydrogels are commonly used for a broad range of biomedical applications. As long as the polymer volume is accessible, gels can easily be hardened using light illumination. However, in clinics, especially for minimally invasive surgery, it becomes highly challenging to control photopolymerization. The ratios between polymerizationvolume and radiating-surface-area are several orders of magnitude higher than for ex-vivo settings. Also tissue scattering occurs and influences the reaction. We developed a Monte Carlo model for photopolymerization, which takes into account the solid/liquid phase changes, moving solid/liquid-boundaries and refraction on these boundaries as well as tissue scattering in arbitrarily designable tissue cavities. The model provides a tool to tailor both the light probe and the scattering/absorption properties of the photopolymer for applications such as medical implants or tissue replacements. Based on the simulations, we have previously shown that by adding scattering additives to the liquid monomer, the photopolymerized volume was considerably increased. In this study, we have used bovine intervertebral disc cavities, as a model for spinal degeneration, to study photopolymerization in-vitro. The cavity is created by enzyme digestion. Using a custom designed probe, hydrogels were injected and photopolymerized. Magnetic resonance imaging (MRI) and visual inspection tools were employed to investigate the successful photopolymerization outcomes. The results provide insights for the development of novel endoscopic light-scattering polymerization probes paving the way for a new generation of implantable hydrogels.

  11. The Astral Curved Disc of Chevroches (France)

    NASA Astrophysics Data System (ADS)

    Devevey, F. Rousseau, A.

    2009-08-01

    The excavation of the unexplored secondary agglomeration in Chevroches (Nièvre), from 2001 to 2002, directed by F. Devevey (INRAP), has led to the discovery of an astrological bronze curved disc of a type unknown in the ancient world; it is inscribed with three lines in Greek transcribing Egyptian an Roman months, and the twelve signs of the zodiac. This article presents the first observations.

  12. Development of fluorescent multilayer disc structure

    NASA Astrophysics Data System (ADS)

    Beliak, Ievgen; Butenko, Larisa

    2011-09-01

    The fluorescent multilayer disc (FMD) consists of a substrate and the sandwich-structure of information and intermediate layers. While all the structure of the disc is transparent and homogeneous the parasitic signal will be caused mostly by photoluminescence (PL) and absorption of pits areas where laser light is unfocused. At large number of layers (10 or more) the noise level will get significant value, so it was suggested to derive readout signal as a variable one. Also it was proposed to record information only by the lands, to decrease the absorbance level and thus uncontrolled changing of the noise level. Furthermore in the FMD information layer there are inner and outside peripheral areas which hold a stable level of parasitic signal during readout from the edges of the disc. While the PL readout signal is spatially isotropic the optical head of the FMD drive receives just a part of the probing beam energy. PL quantum yield, absorption factor, receiver systems exposure loss coefficients are other reasons of the low PL signal. Thus the problem of the low SNR in this case is a major one and the only way of its solving is synthesis of the dye with a high PL quantum yield. The PL relaxation time on the other hand is a main feature of the data reading rate and therefore selection of the appropriate recording material will allow to bring this parameter in accordance to parameters of modern optical discs. To achieve this goal the composite organic pyrazoline dyes where synthesized and investigated as effective medium with a PL quantum yield up to 60-70%, relaxation time less than 100 ns, PL wide spectrum and opportunity of two-photon absorption. These parameters were further improved by a method based on the performance of organic dye molecules in the zeolite matrix.

  13. Can Exercise Positively Influence the Intervertebral Disc?

    PubMed

    Belavý, Daniel L; Albracht, Kirsten; Bruggemann, Gert-Peter; Vergroesen, Pieter-Paul A; van Dieën, Jaap H

    2016-04-01

    To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a 'critical period' for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research.

  14. Lumbar Disc Herniation Presented with Contralateral Symptoms

    PubMed Central

    Kim, Pius; Ju, Chang Il; Kim, Hyeun Sung; Kim, Seok Won

    2017-01-01

    Objective This study aimed to unravel the putative mechanism underlying the neurologic deficits contralateral to the side with lumbar disc herniation (LDH) and to elucidate the treatment for this condition. Methods From January 2009 to June 2015, 8 patients with LDH with predominantly contralateral neurologic deficits underwent surgical treatment on the side with LDH with or without decompressing the symptomatic side. A retrospective review of charts and radiological records of these 8 patients was performed. The putative mechanisms underlying the associated contralateral neurological deficits, magnetic resonance imaging (MRI), electromyography (EMG), and the adequate surgical approach are discussed here. Results MRI revealed a similar laterally skewed paramedian disc herniation, with the apex deviated from the symptomatic side rather than directly compressing the nerve root; this condition may generate a contralateral traction force. EMG revealed radiculopathies in both sides of 6 patients and in the herniated side of 2 patients. Based on EMG findings and the existence of suspicious lateral recess stenosis of the symptomatic side, 6 patients underwent bilateral decompression of nerve roots and 2 were subjected to a microscopic discectomy to treat the asymptomatic disc herniation. No specific conditions such as venous congestion, nerve root anomaly or epidural lipomatosis were observed, which may be considered the putative pathomechanism causing the contralateral neurological deficits. The symptoms resolved significantly after surgery. Conclusion The traction force generated on the contralateral side and lateral recess stenosis, rather than direct compression, may cause the contralateral neurologic deficits observed in LDH. PMID:28264243

  15. Engineering alginate for intervertebral disc repair.

    PubMed

    Bron, Johannes L; Vonk, Lucienne A; Smit, Theodoor H; Koenderink, Gijsje H

    2011-10-01

    Alginate is frequently studied as a scaffold for intervertebral disc (IVD) repair, since it closely mimics mechanical and cell-adhesive properties of the nucleus pulposus (NP) of the IVD. The aim of this study was to assess the relation between alginate concentration and scaffold stiffness and find preparation conditions where the viscoelastic behaviour mimics that of the NP. In addition, we measured the effect of variations in scaffold stiffness on the expression of extracellular matrix molecules specific to the NP (proteoglycans and collagen) by native NP cells. We prepared sample discs of different concentrations of alginate (1%-6%) by two different methods, diffusion and in situ gelation. The stiffness increased with increasing alginate concentration, while the loss tangent (dissipative behaviour) remained constant. The diffusion samples were ten-fold stiffer than samples prepared by in situ gelation. Sample discs prepared from 2% alginate by diffusion closely matched the stiffness and loss tangent of the NP. The stiffness of all samples declined upon prolonged incubation in medium, especially for samples prepared by diffusion. The biosynthetic phenotype of native cells isolated from NPs was preserved in alginate matrices up to 4 weeks of culturing. Gene expression levels of extracellular matrix components were insensitive to alginate concentration and corresponding matrix stiffness, likely due to the poor adhesiveness of the cells to alginate. In conclusion, alginate can mimic the viscoelastic properties of the NP and preserve the biosynthetic phenotype of NP cells but certain limitations like long-term stability still have to be addressed.

  16. Testing hydrodynamics schemes in galaxy disc simulations

    NASA Astrophysics Data System (ADS)

    Few, C. G.; Dobbs, C.; Pettitt, A.; Konstandin, L.

    2016-08-01

    We examine how three fundamentally different numerical hydrodynamics codes follow the evolution of an isothermal galactic disc with an external spiral potential. We compare an adaptive mesh refinement code (RAMSES), a smoothed particle hydrodynamics code (SPHNG), and a volume-discretized mesh-less code (GIZMO). Using standard refinement criteria, we find that RAMSES produces a disc that is less vertically concentrated and does not reach such high densities as the SPHNG or GIZMO runs. The gas surface density in the spiral arms increases at a lower rate for the RAMSES simulations compared to the other codes. There is also a greater degree of substructure in the SPHNG and GIZMO runs and secondary spiral arms are more pronounced. By resolving the Jeans length with a greater number of grid cells, we achieve more similar results to the Lagrangian codes used in this study. Other alterations to the refinement scheme (adding extra levels of refinement and refining based on local density gradients) are less successful in reducing the disparity between RAMSES and SPHNG/GIZMO. Although more similar, SPHNG displays different density distributions and vertical mass profiles to all modes of GIZMO (including the smoothed particle hydrodynamics version). This suggests differences also arise which are not intrinsic to the particular method but rather due to its implementation. The discrepancies between codes (in particular, the densities reached in the spiral arms) could potentially result in differences in the locations and time-scales for gravitational collapse, and therefore impact star formation activity in more complex galaxy disc simulations.

  17. Spinning disc atomisation process: Modelling and computations

    NASA Astrophysics Data System (ADS)

    Li, Yuan; Sisoev, Grigory; Shikhmurzaev, Yulii

    2016-11-01

    The atomisation of liquids using a spinning disc (SDA), where the centrifugal force is used to generate a continuous flow, with the liquid eventually disintegrating into drops which, on solidification, become particles, is a key element in many technologies. Examples of such technologies range from powder manufacturing in metallurgy to various biomedical applications. In order to be able to control the SDA process, it is necessary to understand it as a whole, from the feeding of the liquid and the wave pattern developing on the disc to the disintegration of the liquid film into filaments and these into drops. The SDA process has been the subject of a number of experimental studies and some elements of it, notably the film on a spinning disc and the dynamics of the jets streaming out from it, have been investigated theoretically. However, to date there have been no studies of the process as a whole, including, most importantly, the transition zone where the film that has already developed a certain wave pattern disintegrates into jets that spiral out. The present work reports some results of an ongoing project aimed at producing a definitive map of regimes occurring in the SDA process and their outcome.

  18. Reactive thin film flows over spinning discs

    NASA Astrophysics Data System (ADS)

    Zhao, Kun; Wray, Alex; Yang, Junfeng; Matar, Omar

    2015-11-01

    We consider the dynamics of a thin film flowing over a spinning disc in the presence of a chemical reaction, and associated heat and mass transfer. We use a boundary-layer approximation in conjunction with the Karman-Polhausen approximation for the velocity distribution in the film to derive a set of coupled one-dimensional evolution equations for the film thickness, radial and azimuthal flow rates, concentration of the reagents and products, and temperature. These highly nonlinear partial differential equations are solved numerically to reveal the formation of large-amplitude waves that travel from the disc inlet to its periphery. The influence of these waves on the concentration and temperature profiles is analysed for a wide range of system parameters: the Damkohler and Schmidt numbers, the thermal Peclet numbers, and the dimensionless disc radius (a surrogate for the Eckman number). It is shown that these waves lead to significant enhancement of the rates of heat and mass transfer associated with the reactive flow; these are measured by tracking the temporal evolution of local and spatially-averaged Nusselt and Sherwood numbers, respectively. EPSRC Programme Grant, MEMPHIS, EP/K0039761/1.

  19. Risk Factors for Recurrent Lumbar Disc Herniation

    PubMed Central

    Huang, Weimin; Han, Zhiwei; Liu, Jiang; Yu, Lili; Yu, Xiuchun

    2016-01-01

    Abstract Recurrent lumbar disc herniation (rLDH) is a common complication following primary discectomy. This systematic review aimed to investigate the current evidence on risk factors for rLDH. Cohort or case-control studies addressing risk factors for rLDH were identified by search in Pubmed (Medline), Embase, Web of Science, and Cochrane library from inception to June 2015. Relevant results were pooled to give overall estimates if possible. Heterogeneity among studies was examined and publication bias was also assessed. A total of 17 studies were included in this systematic review. Risk factors that had significant relation with rLDH were smoking (OR 1.99, 95% CI 1.53–2.58), disc protrusion (OR 1.79, 95% CI 1.15–2.79), and diabetes (OR 1.19, 95% CI 1.06–1.32). Gender, BMI, occupational work, level, and side of herniation did not correlate with rLDH significantly. Based on current evidence, smoking, disc protrusion, and diabetes were predictors for rLDH. Patients with these risk factors should be paid more attention for prevention of recurrence after primary surgery. More evidence provided by high-quality observational studies is still needed to further investigate risk factors for rLDH. PMID:26765413

  20. Valve replacement in children. A fifteen-year perspective.

    PubMed

    Gardner, T J; Roland, J M; Neill, C A; Donahoo, J S

    1982-02-01

    Between 1965 and 1980, 64 children form 1 to 19 years of age have undergone replacement of the aortic, mitral, or tricuspid valve at The Johns Hopkins Hospital. Three of these patients have had successful second valve replacements 4 to 12 years after the initial operation. During the first 5 year period of this review, the hospital mortality was 31%, whereas only one of 33 children having valve replacement during the most recent 5 year period died early after operation (hospital mortality, 1976 to 1980, 3%). Thromboembolic complications have been seen in only two patients in this group, for an incidence of 0.8% per patient-year. Among patients receiving long-term warfarin anticoagulation, there has been only one major bleeding episode in 133 patient-years of follow-up. The type of valve prosthesis implanted during this 15 year period has changed greatly. Ninety-four percent of the prostheses placed during the initial 5 year period were the caged-poppet type of valve, whereas tilting disc, central flow, and tissue valve substitutes have been implanted more recently. Eight of the 10 patients most recently undergoing valve replacement have received St. Jude Medical prostheses, and postoperative catheterization studies have confirmed the excellent hemodynamic performance of these valves, even in patients with prostheses of very small annular diameter. Despite the disappointing occurrence of premature tissue valve failure in the young population, valve replacement in children currently is safer and there is a wider variety of technically satisfactory valve substitutes available for implantation today.

  1. Be discs in binary systems - I. Coplanar orbits

    NASA Astrophysics Data System (ADS)

    Panoglou, Despina; Carciofi, Alex C.; Vieira, Rodrigo G.; Cyr, Isabelle H.; Jones, Carol E.; Okazaki, Atsuo T.; Rivinius, Thomas

    2016-09-01

    Be stars are surrounded by outflowing circumstellar matter structured in the form of decretion discs. They are often members of binary systems, where it is expected that the decretion disc interacts both radiatively and gravitationally with the companion. In this work we study how various orbital (period, mass ratio and eccentricity) and disc (viscosity) parameters affect the disc structure in coplanar binaries. The main effects of the secondary on the disc are its truncation and the accumulation of material inwards of truncation. We find two limiting cases with respect to the effects of eccentricity: in circular or nearly circular prograde orbits, the disc maintains a rotating, constant in shape, configuration, which is locked to the orbital phase. The disc structure appears smaller in size, more elongated and more massive for small viscosity parameter, small orbital separation and/or high mass ratio. In highly eccentric orbits, the effects are more complex, with the disc structure strongly dependent on the orbital phase. We also studied the effects of binarity in the disc continuum emission. Since the infrared and radio SED are sensitive to the disc size and density slope, the truncation and matter accumulation result in considerable modifications in the emergent spectrum. We conclude that binarity can serve as an explanation for the variability exhibited in observations of Be stars, and that our model can be used to detect invisible companions.

  2. Solute transport in intervertebral disc: experiments and finite element modeling.

    PubMed

    Das, D B; Welling, A; Urban, J P G; Boubriak, O A

    2009-04-01

    Loss of nutrient supply to the human intervertebral disc (IVD) cells is thought to be a major cause of disc degeneration in humans. To address this issue, transport of molecules of different size have been analyzed by a combination of experimental and modeling studies. Solute transport has been compared for steady-state and transient diffusion of several different solutes with molecular masses in the range 3-70 kDa, injected into parts of the disc where degeneration is thought most likely to occur first and into the blood supply to the disc. Diffusion coefficients of fluorescently tagged dextran molecules of different molecular weights have been measured in vitro using the concentration gradient technique in thin specimens of disc outer annulus and nucleus pulposus. Diffusion coefficients were found to decrease with molecular weight following a nonlinear relationship. Diffusion coefficients changed more rapidly for solutes with molecular masses less than 10 kDa. Although unrealistic or painful, solutes injected directly into the disc achieve the largest disc coverage with concentrations that would be high enough to be of practical use. Although more practical, solutes injected into the blood supply do not penetrate to the central regions of the disc and their concentrations dissipate more rapidly. Injection into the disc would be the best method to get drugs or growth factors to regions of degeneration in IVDs quickly; else concentrations of solute must be kept at a high value for several hours in the blood supply to the discs.

  3. BP Piscium: its flaring disc imaged with SPHERE/ZIMPOL★

    NASA Astrophysics Data System (ADS)

    de Boer, J.; Girard, J. H.; Canovas, H.; Min, M.; Sitko, M.; Ginski, C.; Jeffers, S. V.; Mawet, D.; Milli, J.; Rodenhuis, M.; Snik, F.; Keller, C. U.

    2017-03-01

    Whether BP Piscium (BP Psc) is either a pre-main sequence T Tauri star at d ≈ 80 pc, or a post-main sequence G giant at d ≈ 300 pc is still not clear. As a first-ascent giant, it is the first to be observed with a molecular and dust disc. Alternatively, BP Psc would be among the nearest T Tauri stars with a protoplanetary disc (PPD). We investigate whether the disc geometry resembles typical PPDs, by comparing polarimetric images with radiative transfer models. Our Very Large Telescope/Spectro-Polarimetric High-contrast Exoplanet REsearch (SPHERE)/Zurich IMaging Polarimeter (ZIMPOL) observations allow us to perform polarimetric differential imaging, reference star differential imaging, and Richardson-Lucy deconvolution. We present the first visible light polarization and intensity images of the disc of BP Psc. Our deconvolution confirms the disc shape as detected before, mainly showing the southern side of the disc. In polarized intensity the disc is imaged at larger detail and also shows the northern side, giving it the typical shape of high-inclination flared discs. We explain the observed disc features by retrieving the large-scale geometry with MCMAX radiative transfer modelling, which yields a strongly flared model, atypical for discs of T Tauri stars.

  4. Temperature effects on pitfall catches of epigeal arthropods: a model and method for bias correction

    PubMed Central

    Saska, Pavel; van der Werf, Wopke; Hemerik, Lia; Luff, Martin L; Hatten, Timothy D; Honek, Alois; Pocock, Michael

    2013-01-01

    Carabids and other epigeal arthropods make important contributions to biodiversity, food webs and biocontrol of invertebrate pests and weeds. Pitfall trapping is widely used for sampling carabid populations, but this technique yields biased estimates of abundance (‘activity-density’) because individual activity – which is affected by climatic factors – affects the rate of catch. To date, the impact of temperature on pitfall catches, while suspected to be large, has not been quantified, and no method is available to account for it. This lack of knowledge and the unavailability of a method for bias correction affect the confidence that can be placed on results of ecological field studies based on pitfall data. Here, we develop a simple model for the effect of temperature, assuming a constant proportional change in the rate of catch per °C change in temperature, r, consistent with an exponential Q10 response to temperature. We fit this model to 38 time series of pitfall catches and accompanying temperature records from the literature, using first differences and other detrending methods to account for seasonality. We use meta-analysis to assess consistency of the estimated parameter r among studies. The mean rate of increase in total catch across data sets was 0·0863 ± 0·0058 per °C of maximum temperature and 0·0497 ± 0·0107 per °C of minimum temperature. Multiple regression analyses of 19 data sets showed that temperature is the key climatic variable affecting total catch. Relationships between temperature and catch were also identified at species level. Correction for temperature bias had substantial effects on seasonal trends of carabid catches. Synthesis and Applications. The effect of temperature on pitfall catches is shown here to be substantial and worthy of consideration when interpreting results of pitfall trapping. The exponential model can be used both for effect estimation and for bias correction of observed data. Correcting for

  5. Promises and pitfalls of live attenuated pneumococcal vaccines.

    PubMed

    Rosch, Jason W

    2014-01-01

    The pneumococcus is a remarkably adaptable pathogen whose disease manifestations range from mucosal surface infections such as acute otitis media and pneumonia to invasive infections such as sepsis and meningitis. Currently approved vaccines target the polysaccharide capsule, of which there are over 90 distinct serotypes, leading to rapid serotype replacement in vaccinated populations. Substantial progress has been made in the development of a universal pneumococcal vaccine, with efforts focused on broadly conserved and protective protein antigens. An area attracting considerable attention is the potential application of live attenuated vaccines to confer serotype-independent protection against mucosal and systemic infection. On the basis of recent work to understand the mucosal and systemic responses to nasal administration of pneumococci and to develop novel attenuation strategies, the prospect of a practical and protective live vaccine remains promising.

  6. Total Disc Arthroplasty and Anterior Cervical Discectomy and Fusion in Cervical Spine: Competitive or Complimentary? Review of the Literature

    PubMed Central

    Jawahar, Ajay; Nunley, Pierce

    2012-01-01

    Anterior cervical discectomy and arthrodesis has come to represent standard of care for patients with persistent radicular and/or myelopathic symptoms that have failed to improve with conservative treatments. One potential complication of the procedure is the accelerated degeneration of the vertebrae and the intervertebral discs adjacent to the level fused and the effects of fusion on those levels. The concern that fusion may be a contributing factor to accelerated adjacent segment degeneration led to increased interest in cervical disc replacement after anterior decompressive surgery. Several studies analyzing the short-term outcomes of the disc replacement procedure have been published since then, and the pros and cons of both procedures continue to remain a topic of debate among the scientific community. The analysis of published literature and our own experience has convinced us that the overall longer-term clinical outcomes after anterior cervical discectomy and fusion (ACDF) and total disc replacement (TDR) in the general patient population are not significantly different in terms of symptomatic improvement, neurological improvement, and restoration to better quality of life. Age of the patients and number of affected levels may impact the outcomes and hence determine the choice of optimum procedure. To definitely compare the incidence of adjacent segment disease after these procedures, multi-institutional studies with predetermined and unanimously agreed upon clinical and radiological criteria should be undertaken and the results analyzed in an unbiased fashion. Until that time, it is reasonable to assume that ACDF as well as cervical TDR are both safe and effective procedures that may have outcome benefits in specific patient subgroups based upon demographics and clinical/radiological parameters at the time of surgery. PMID:24353966

  7. Interpretation of EMG changes with fatigue: facts, pitfalls, and fallacies.

    PubMed

    Dimitrova, N A; Dimitrov, G V

    2003-02-01

    Failure to maintain the required or expected force, defined as muscle fatigue, is accompanied by changes in muscle electrical activity. Although studied for a long time, reasons for EMG changes in time and frequency domain have not been clear until now. Many authors considered that theory predicted linear relation between the characteristic frequencies and muscle fibre propagation velocity (MFPV), irrespective of the fact that spectral characteristics can drop even without any changes in MFPV, or in proportion exceeding the MFPV changes. The amplitude changes seem to be more complicated and contradictory since data on increased, almost unchanged, and decreased amplitude characteristics of the EMG, M-wave or motor unit potential (MUP) during fatigue can be found in literature. Moreover, simultaneous decrease and increase in amplitude of MUP and M-wave, detected with indwelling and surface electrodes, were referred to as paradoxical. In spite of this, EMG amplitude characteristics are predominantly used when causes for fatigue are analysed. We aimed to demonstrate theoretical grounds for pitfalls and fallacies in analysis of experimental results if changes in intracellular action potential (IAP), i.e. in peripheral factors of muscle fatigue, were not taken into consideration. We based on convolution model of potentials produced by a motor unit and detected by a point or rectangular plate electrode in a homogeneous anisotropic infinite volume conductor. Presentation of MUP in the convolution form gave us a chance to consider power spectrum (PS) of MUP as a product of two terms. The first one, PS of the input signal, represented PS of the first temporal derivative of intracellular action potential (IAP). The second term, PS of the impulse response, took into account MFPV, differences in instants of activation of each fibre, MU anatomy, and MU position in the volume conductor in respect to the detecting electrode. PS presentation through product means that not only

  8. Fracture After Total Hip Replacement

    MedlinePlus

    ... er Total Hip Replacement cont. • Dislocation • Limb length inequality • Poor fracture healing • Repeat fracture • Lack of in- ... Surgeons (AAOS). To learn more about your orthopaedic health, please visit orthoinfo.org. Page ( 5 ) AAOS does ...

  9. Options for Heart Valve Replacement

    MedlinePlus

    ... which may include human or animal donor tissue) Ross Procedure — “Borrowing” your healthy valve and moving it ... Considerations for Surgery Medications Valve Repair Valve Replacement - Ross Procedure - Newer Surgery Options - What is TAVR? - Types ...

  10. Single Project Replaces District's Windows.

    ERIC Educational Resources Information Center

    American School and University, 1981

    1981-01-01

    The towns of Maplewood and South Orange (New Jersey) earmarked over $1 million, raised from a bond issue, to replace with thermal aluminum-framed units the 2400 worn out windows in eight 50-year-old schools. (Author)

  11. Prioritization Methodology for Chemical Replacement

    NASA Technical Reports Server (NTRS)

    Cruit, W.; Schutzenhofer, S.; Goldberg, B.; Everhart, K.

    1993-01-01

    This project serves to define an appropriate methodology for effective prioritization of efforts required to develop replacement technologies mandated by imposed and forecast legislation. The methodology used is a semiquantitative approach derived from quality function deployment techniques (QFD Matrix). This methodology aims to weigh the full environmental, cost, safety, reliability, and programmatic implications of replacement technology development to allow appropriate identification of viable candidates and programmatic alternatives. The results are being implemented as a guideline for consideration for current NASA propulsion systems.

  12. Accretion disc viscosity: a limit on the anisotropy

    NASA Astrophysics Data System (ADS)

    Nixon, Chris

    2015-07-01

    Observations of warped discs can give insight into the nature of angular momentum transport in accretion discs. Only a few objects are known to show strong periodicity on long time-scales, but when such periodicity is present it is often attributed to precession of the accretion disc. The X-ray binary Hercules X-1/HZ Herculis (Her X-1) is one of the best examples of such periodicity and has been linked to disc precession since it was first observed. By using the current best-fitting models to Her X-1, which invoke precession driven by radiation warping, I place a constraint on the effective viscosities that act in a warped disc. These effective viscosities almost certainly arise due to turbulence induced by the magnetorotational instability. The constraints derived here are in agreement with analytical and numerical investigations into the nature of magnetohydrodynamic disc turbulence, but at odds with some recent global simulations.

  13. Pitfalls and Pearls of Wisdom in 18F-FDG PET Imaging of Tumors.

    PubMed

    Britton, Tracey; Robinson, Nicholas

    2016-06-01

    (18)F-FDG PET imaging of tumors has pitfalls and pearls of wisdom that begin at the point of scheduling and continue through the patient interview, the resting phase, the scan itself, and the image review. Interviewing the patient at the time of scheduling, followed by placing a reminder phone call shortly before the appointment, can save a nuclear medicine department the financial loss of wasted doses and missed appointment slots in the schedule. The pitfalls and pearls of wisdom in tumor imaging are ever changing, and the technologist is in a constant state of inquiry about the patient's disease process and ability to comply. Consideration of each item on the worksheets in this article affects every scan. On completing this article, the reader will be able to identify questions that should be asked in the scheduling and preinjection patient interviews, interpret the answers to those questions, determine how the images may be affected, and adapt the scan.

  14. Advantages and pitfalls in the application of mixed-model association methods.

    PubMed

    Yang, Jian; Zaitlen, Noah A; Goddard, Michael E; Visscher, Peter M; Price, Alkes L

    2014-02-01

    Mixed linear models are emerging as a method of choice for conducting genetic association studies in humans and other organisms. The advantages of the mixed-linear-model association (MLMA) method include the prevention of false positive associations due to population or relatedness structure and an increase in power obtained through the application of a correction that is specific to this structure. An underappreciated point is that MLMA can also increase power in studies without sample structure by implicitly conditioning on associated loci other than the candidate locus. Numerous variations on the standard MLMA approach have recently been published, with a focus on reducing computational cost. These advances provide researchers applying MLMA methods with many options to choose from, but we caution that MLMA methods are still subject to potential pitfalls. Here we describe and quantify the advantages and pitfalls of MLMA methods as a function of study design and provide recommendations for the application of these methods in practical settings.

  15. Effects of pitfall trap preservative on collections of carabid beetles (Coleoptera: Carabidae)

    USGS Publications Warehouse

    McCravy, K.W.; Willand, J.E.

    2007-01-01

    Effects of six pitfall trap preservatives (5% acetic acid solution, distilled water, 70% ethanol, 50% ethylene glycol solution, 50% propylene glycol solution, and 10% saline solution) on collections of carabid beetles (Coleoptera: Carabidae) were studied in a west-central Illinois deciduous forest from May to October 2005. A total of 819 carabids, representing 33 species and 19 genera, were collected. Saline produced significantly fewer captures than did acetic acid, ethanol, ethylene glycol, and propylene glycol, while distilled water produced significantly fewer captures than did acetic acid. Significant associations between numbers of captures and treatment were seen in four species: Amphasia interstitialis (Say), Calathus opaculus LeConte, Chlaenius nemoralis Say, and Cyclotrachelus sodalis (LeConte). Results of this study suggest that type of preservative used can have substantial effects on abundance and species composition of carabids collected in pitfall traps.

  16. The promise and pitfalls of sequence-based identification of plant-pathogenic fungi and oomycetes.

    PubMed

    Kang, Seogchan; Mansfield, Michele A; Park, Bongsoo; Geiser, David M; Ivors, Kelly L; Coffey, Michael D; Grünwald, Niklaus J; Martin, Frank N; Lévesque, C André; Blair, Jaime E

    2010-08-01

    Sequences of selected marker loci have been widely used for the identification of specific pathogens and the development of sequence-based diagnostic methods. Although such approaches offer several advantages over traditional culture-based methods for pathogen diagnosis and identification, they have their own pitfalls. These include erroneous and incomplete data in reference databases, poor or oversimplified interpretation of search results, and problems associated with defining species boundaries. In this letter, we outline the potential benefits and drawbacks of using sequence data for identification and taxonomic deduction of plant-pathogenic fungi and oomycetes, using phytophthora as a primary example. We also discuss potential remedies for these pitfalls and address why coordinated community efforts are essential to make such remedies more efficient and robust.

  17. Does diffusion MRI tell us anything about the white matter? An overview of methods and pitfalls

    PubMed Central

    O’Donnell, Lauren J.; Pasternak, Ofer

    2014-01-01

    One key pitfall in diffusion magnetic resonance imaging (dMRI) clinical neuroimaging research is the challenge of understanding and interpreting the results of a complex analysis pipeline. The sophisticated algorithms employed by the analysis software, combined with the relatively non-specific nature of many diffusion measurements, lead to challenges in interpretation of the results. This paper is aimed at an intended audience of clinical researchers who are learning about dMRI or trying to interpret dMRI results, and who may be wondering “Does dMRI tell us anything about the white matter?” We present a critical review of dMRI methods and measures used in clinical neuroimaging research, focusing on the most commonly used analysis methods and the most commonly reported measures. We describe important pitfalls in every section, and provide extensive references for the reader interested in more detail. PMID:25278106

  18. New Brown Dwarf Discs in Upper Scorpius Observed with WISE

    NASA Technical Reports Server (NTRS)

    Dawson, P.; Scholz, A.; Ray, T. P.; Natta, A.; Marsh, K. A.; Padgett, D.; Ressler, M. E.

    2013-01-01

    We present a census of the disc population for UKIDSS selected brown dwarfs in the 5-10 Myr old Upper Scorpius OB association. For 116 objects originally identified in UKIDSS, the majority of them not studied in previous publications, we obtain photometry from the Wide-Field Infrared Survey Explorer data base. The resulting colour magnitude and colour colour plots clearly show two separate populations of objects, interpreted as brown dwarfs with discs (class II) and without discs (class III). We identify 27 class II brown dwarfs, 14 of them not previously known. This disc fraction (27 out of 116, or 23%) among brown dwarfs was found to be similar to results for K/M stars in Upper Scorpius, suggesting that the lifetimes of discs are independent of the mass of the central object for low-mass stars and brown dwarfs. 5 out of 27 discs (19 per cent) lack excess at 3.4 and 4.6 microns and are potential transition discs (i.e. are in transition from class II to class III). The transition disc fraction is comparable to low-mass stars.We estimate that the time-scale for a typical transition from class II to class III is less than 0.4 Myr for brown dwarfs. These results suggest that the evolution of brown dwarf discs mirrors the behaviour of discs around low-mass stars, with disc lifetimes of the order of 5 10 Myr and a disc clearing time-scale significantly shorter than 1 Myr.

  19. Herschel DEBRIS survey of debris discs around A stars

    NASA Astrophysics Data System (ADS)

    Thureau, N.

    2014-11-01

    The Herschel DEBRIS survey (Disc Emission via a Bias-free Reconnaissance in the Infrared/Submillimetre) brings a unique perspective to the study of debris discs around main-sequence A-type stars. We have observed a sample of 89 A-stars with the Photodetector Array Camera and Spectrometer (PACS) on the Herschel space telescope at 100 and 160 μm. A statistical analysis of the data shows a lower debris disc rate than has previously been found. The drop is due in part to the fact that some excess sources were resolved as background objects by the superior angular resolution (a factor of 2.5) of PACS-100 relative to that of Spitzer (MIPS-70). We found a 3-σ detection rate of 23 myblue which is similar to the the detection rate around main-sequence F, G and K stars. Most of the debris discs were detected around the youngest and hottest stars in our sample. The incidence of discs in single and multiple systems was similar. The debris discs in multiple systems ware found either in tight binary systems (<1 AU) or wide ones (>100 AU). Debris discs in both tight and wide binary systems have physical properties that are statistically similar to those of discs around single stars. We did not detect any debris discs in binary systems with intermediate separation, in which the orbit and the debris disc would be on the same scale. One possible explanation is that discs in intermediate systems have evolved much faster owing to the disc-companion interactions and they are now undetectable.

  20. Glaucomatous-Type Optic Discs in High Myopia

    PubMed Central

    Nagaoka, Natsuko; Jonas, Jost B.; Morohoshi, Kei; Moriyama, Muka; Shimada, Noriaki; Yoshida, Takeshi; Ohno-Matsui, Kyoko

    2015-01-01

    Purpose To assess the prevalence of glaucoma in patients with high myopia defined as myopic refractive error of >-8 diopters or axial length ≥26.5 mm. Methods The hospital-based observational study included 172 patients (336 eyes) with a mean age of 61.9±12.3 years and mean axial length of 30.1±2.3 mm (range: 24.7–39.1mm). Glaucomatous-type optic discs were defined by glaucomatous optic disc appearance. Glaucoma was defined by glaucomatous optic disc appearance and glaucomatous Goldmann visual field defects not corresponding with myopic macular changes. Results Larger disc area (mean: 3.18±1.94 mm2) was associated with longer axial length (P<0.001; standardized correlation coefficient: 0.45). Glaucoma was detected in 94 (28%; 95% Confidence intervals: 23%, 33%) eyes. In multivariate analysis, glaucoma prevalence was 3.2 times higher (P<0.001) in megalodiscs (>3.79 mm2) than in normal-sized discs or small discs (<1.51 mm2) after adjusting for older age. Axial length was not significantly (P = 0.38) associated with glaucoma prevalence in that model. Glaucoma prevalence increased by a factor of 1.39 for each increase in optic disc area by one mm2. Again, axial length was not significantly (P = 0.38) associated with glaucoma prevalence when added to this multivariate model. Conclusion Within highly myopic individuals, glaucoma prevalence increased with larger optic disc size beyond a disc area of 3.8 mm2. Highly myopic megalodiscs as compared to normal sized discs or small discs had a 3.2 times higher risk for glaucomatous optic nerve neuropathy. The increased glaucoma prevalence in axial high myopia was primarily associated with axial myopia associated disc enlargement and not with axial elongation itself. PMID:26425846

  1. Mode I and Mode III fractures in intermediate zone of full-thickness porcine temporomandibular joint discs.

    PubMed

    Beatty, Mark W; Hohl, Rebecca H; Nickel, Jeffrey C; Iwasaki, Laura R; Pidaparti, Ramana M

    2008-05-01

    The aim of this study was to assess the critical energy required to induce flaw propagation in the temporomandibular joint (TMJ) disc when tensile and shear stresses were applied. J-integrals were measured for Mode I and III fractures because excessive tensile and shear stresses promote disc failure. Single edge notch (Mode I) and trouser tear (Mode III) specimens were constructed with flaws oriented parallel to the predominant anteroposteriorly oriented collagen fibers of the TMJ disc. Disks with and without an impulsive pre-load of 3 N s were studied to compare impact-damaged and healthy tissues. Results demonstrated that impulsive loading stiffened the tissues and significantly increased the Mode I fracture energy (J (IC)) but not Mode III (J (IIIC)) (p < or = 0.05). J (IC) and J (IIIC) values were similar for undamaged tissues, but J (IC) values were 2.3 times higher for impulsively loaded tissues (p < or = 0.05). This suggests that when flaws are introduced through impact, the TMJ disc responds by requiring more energy for tensile flaw extension. This research is a first step towards characterizing the mechanical microenvironment that initiates joint disease. This characterization is essential for successful integration of engineered replacement tissues for damaged TMJs.

  2. Audiovisual Bounce-Inducing Effect: Attention Alone Does Not Explain Why the Discs Are Bouncing

    ERIC Educational Resources Information Center

    Grassi, Massimo; Casco, Clara

    2009-01-01

    Two discs moving from opposite points in space, overlapping and stopping at the other disc's starting point, can be seen as either bouncing or streaming through each other. With silent displays, observers report the discs as streaming, whereas if a sound is played when the discs touch each other, observers report the discs as bouncing. The origin…

  3. Diagnostic pitfalls in fine-needle aspiration cytology of temporomandibular chondroblastoma: report of two cases.

    PubMed

    Cabrera, Rafael Adame; Almeida, Margarida; Mendonça, M Evelina; Frable, W J

    2006-06-01

    Chondroblastoma is a benign bone neoplasm, which usually presents in the epiphysis of long bones, but can occur in unusual locations. This report describes the clinical, radiologic, and cytologic features on FNA of two chondroblastomas of the temporomandibular region that were only recognized by histopathologic study. This emphasizes the diagnostic pitfalls of this entity and expands the cytologic differential diagnosis of tumors of the parotid region.

  4. Some reflections on a few of the pitfalls in the world of foundation grant making.

    PubMed

    Billings, John

    2007-01-01

    This paper offers some reflections on the grant-making process from a former foundation executive. Some of the opportunities, challenges, and pitfalls inherent in the foundation world are described, and one approach to grant making, the "call for proposals," is examined as an example of the need for greater attention to and investment in the science of grant making itself, to maximize the potential return from philanthropy.

  5. Estimating the difference limen in 2AFC tasks: pitfalls and improved estimators.

    PubMed

    Ulrich, Rolf; Vorberg, Dirk

    2009-08-01

    Discrimination performance is often assessed by measuring the difference limen (DL; or just noticeable difference) in a two-alternative forced choice (2AFC) task. Here, we show that the DL estimated from 2AFC percentage-correct data is likely to systematically under- or overestimate true discrimination performance if order effects are present. We show how pitfalls with the 2AFC task may be avoided and suggest a novel approach for analyzing 2AFC data.

  6. Venous Intravasation: A Potential Pitfall of Confirmatory Hysterosalpingogram Following Essure Hysteroscopic Sterilization

    PubMed Central

    Chang, Michael C.; Shim, John J.

    2012-01-01

    Indications for hysterosalpingography (HSG) include evaluation of infertility, spontaneous abortions, postoperative evaluation of tubal ligation, pre-myomectomy evaluation, and more recently, evaluation of tubal occlusion after placement of the Essure Permanent Birth Control System. Here we report a case of venous intravasation during a routine post-Essure HSG, a phenomenon in which contrast transits from the uterine cavity, through the myometrium, and directly into draining pelvic veins. Venous intravasation is a potential pitfall in interpretation of HSGs. PMID:23378884

  7. An injectable nucleus replacement as an adjunct to microdiscectomy: 2 year follow-up in a pilot clinical study

    PubMed Central

    Schwarzenbach, Othmar

    2009-01-01

    Literature indicates that loss of disc tissue from herniation and/or surgery can accelerate degeneration of the disc. The associated loss of disc height may correspond with recurrent back and/or leg pain. A novel hydrogel has been developed to replace lost nucleus pulposus and potentially restore normal disc biomechanics following herniation and surgery. A single-center, non-randomized, prospective feasibility study was undertaken to investigate the use of NuCore® Injectable Nucleus hydrogel (Spine Wave, Inc., Shelton, CT, USA) as a replacement for nuclear tissue lost to herniation and microdiscectomy. Fourteen patients were enrolled at the authors’ hospital as the initial site in a worldwide multicenter pilot study. Subjects who were entered into the study suffered from radicular pain due to single-level herniated nucleus pulposus and were non-respondent to conservative therapy. Following a standard microdiscectomy procedure, the hydrogel material was injected into the nuclear void to replace what tissue had been lost to the herniation and surgery. Leg and back pain, function and disability scores were monitored pre- and post-operatively through 2 years. Neurologic and physical evaluations, blood and serum analyses, and radiographic evaluations of disc height and implant stability were also performed. Results showed significant improvement for leg and back pain, as well as function scores. No complications or device related adverse events were observed. MR controls confirmed stable position of the implants with no reherniations. Radiographic measurements indicated better maintenance of disc height compared to literature data on microdiscectomy alone. The NuCore® material appears to protect the disc from early collapse following microdiscectomy; and therefore, may have the potential to slow the degenerative cascade of the spinal segment over time. PMID:19688352

  8. Accuracy of pitfall traps for monitoring populations of the amphipod Orchestia gammarella (Pallas 1766) in saltmarshes

    NASA Astrophysics Data System (ADS)

    Mantzouki, Evanthia; Ysnel, Frédéric; Carpentier, Alexandre; Pétillon, Julien

    2012-11-01

    The intertidal amphipod Orchestia gammarella displays a key role in the functioning of sand and salt marsh habitats, mainly due to its role in decomposition processes and as a main prey item for fish and birds. This study evaluates the accuracy of two sampling methods for estimating population size, biomass and cohort composition. Pitfall trapping, a passive and easily displayed method, was compared with the depletion of quadrats, an active and time-consuming method, considered here as the reference method. Sampling took place in North-West European saltmarshes (Mont Saint-Michel Bay, France) during the summer, 2003 (64 replicates per method). Linear regression revealed that activity-densities (number of individuals per trap) were strongly and positively correlated with densities (number of individuals per quadrat). Dry biomasses obtained from the two sampling methods were also significantly and positively correlated, but with a low coefficient of correlation. Cohort composition differed between the methods, with proportionally less juveniles and more intermediates in pitfall traps. We conclude that pitfall traps can be used for easily monitoring changes in the size, and to a lesser extent for measuring the biomass, of an amphipod population, but not for estimating its cohort composition.

  9. Pitfalls associated with open reduction and internal fixation of fractured ribs.

    PubMed

    Sarani, Babak; Schulte, Leah; Diaz, Jose J

    2015-12-01

    Rib fracture is exceedingly common and remains a leading cause of death in patients with chest injury. Probability of death increases by 19% with each broken rib, and the probability of death increases further with age. Treatment is centered on pain control and early mobilization to provide adequate pulmonary hygiene. Multimodality interventions, such as incentive spirometry, postural changes, and coughing, are pivotal in minimizing the risk of pneumonia and death. Recently, many studies have found mortality benefit to operation fixation (ORIF) of ribs in select patients. However, this procedure remains underutilized partly due to lack of familiarity with its technique and pitfalls by trauma surgeons, in particular. Whereas there are publications on operative technique, there are no studies describing pitfalls associated with this procedure. The purpose of this paper is to describe pitfalls on the technical aspects of ORIF of the ribs based on the medical literature where possible and based on our experience in instances where peer reviewed evidence is lacking. The paper is not meant to serve as a protocol for managing rib fractures.

  10. Active Search on Carcasses versus Pitfall Traps: a Comparison of Sampling Methods.

    PubMed

    Zanetti, N I; Camina, R; Visciarelli, E C; Centeno, N D

    2016-04-01

    The study of insect succession in cadavers and the classification of arthropods have mostly been done by placing a carcass in a cage, protected from vertebrate scavengers, which is then visited periodically. An alternative is to use specific traps. Few studies on carrion ecology and forensic entomology involving the carcasses of large vertebrates have employed pitfall traps. The aims of this study were to compare both sampling methods (active search on a carcass and pitfall trapping) for each coleopteran family, and to establish whether there is a discrepancy (underestimation and/or overestimation) in the presence of each family by either method. A great discrepancy was found for almost all families with some of them being more abundant in samples obtained through active search on carcasses and others in samples from traps, whereas two families did not show any bias towards a given sampling method. The fact that families may be underestimated or overestimated by the type of sampling technique highlights the importance of combining both methods, active search on carcasses and pitfall traps, in order to obtain more complete information on decomposition, carrion habitat and cadaveric families or species. Furthermore, a hypothesis advanced on the reasons for the underestimation by either sampling method showing biases towards certain families. Information about the sampling techniques indicating which would be more appropriate to detect or find a particular family is provided.

  11. Surgery of the ear and the lateral skull base: pitfalls and complications

    PubMed Central

    Schick, Bernhard; Dlugaiczyk, Julia

    2013-01-01

    Surgery of the ear and the lateral skull base is a fascinating, yet challenging field in otorhinolaryngology. A thorough knowledge of the associated complications and pitfalls is indispensable for the surgeon, not only to provide the best possible care to his patients, but also to further improve his surgical skills. Following a summary about general aspects in pre-, intra-and postoperative care of patients with disorders of the ear/lateral skull base, this article covers the most common pitfalls and complications in stapes surgery, cochlear implantation and surgery of vestibular schwannomas and jugulotympanal paragangliomas. Based on these exemplary procedures, basic “dos and don’ts” of skull base surgery are explained, which the reader can easily transfer to other disorders. Special emphasis is laid on functional aspects, such as hearing, balance and facial nerve function. Furthermore, the topics of infection, bleeding, skull base defects, quality of life and indication for revision surgery are discussed. An open communication about complications and pitfalls in ear/lateral skull base surgery among surgeons is a prerequisite for the further advancement of this fascinating field in ENT surgery. This article is meant to be a contribution to this process. PMID:24403973

  12. Langerhans cells in anaplastic Kaposi sarcoma with a paucivascular phenotype: a potential diagnostic pitfall.

    PubMed

    Ramdial, Pratistadevi K; Sing, Yetish; Naicker, Shaun; Calonje, Eduardo; Sewram, Vikash; Singh, Bhugwan

    2011-04-01

    Anaplastic Kaposi sarcoma (AKS), a rare variant of Kaposi sarcoma, has a poorly recognized histomorphologic spectrum, including a paucivascular phenotype, that mimics a range of undifferentiated malignancies. This study, that highlights the hitherto undocumented phenomenon of S100-protein-positive Langerhans cells (SLCs) as a potential diagnostic pitfall in paucivascular AKS, involved review of nine such AKS that required diagnostic immunohistochemical (IHC) work-up. All biopsies had a predominant or exclusive spindle or epithelioid cell infiltrate. The first three tumors were diagnosed as malignant peripheral nerve sheath tumor (2) and metastatic melanoma (1), based on S100-protein immunopositivity. Biopsy of a co-existent pigmented sole lesion (patient 3) demonstrated nodular KS. Subsequent IHC investigation of these three tumors demonstrated an endothelial phenotype and HHV8 immunopositivity, confirming AKS. CD1a and langerin staining of the S100-protein-positive cells confirmed Langerhans cells as the cause of the diagnostic pitfall. Subsequently, six further paucivascular AKS with intratumoral SLCs were recognized on histomorphological and IHC appraisal. In conclusion, heightened awareness of the histomorphologic spectrum, appropriate IHC investigation, and informed appraisal thereof, are critical to the diagnosis of AKS with an undifferentiated phenotype, and the avoidance of IHC pitfalls, such as those caused by under-recognition and misinterpretation of bystander SLCs in AKS.

  13. Apparent quasar disc sizes in the "bird's nest" paradigm

    NASA Astrophysics Data System (ADS)

    Abolmasov, P.

    2017-04-01

    Context. Quasar microlensing effects make it possible to measure the accretion disc sizes around distant supermassive black holes that are still well beyond the spatial resolution of contemporary instrumentation. The sizes measured with this technique appear inconsistent with the standard accretion disc model. Not only are the measured accretion disc sizes larger, but their dependence on wavelength is in most cases completely different from the predictions of the standard model. Aims: We suggest that these discrepancies may arise not from non-standard accretion disc structure or systematic errors, as it was proposed before, but rather from scattering and reprocession of the radiation of the disc. In particular, the matter falling from the gaseous torus and presumably feeding the accretion disc may at certain distances become ionized and produce an extended halo that is free from colour gradients. Methods: A simple analytical model is proposed assuming that a geometrically thick translucent inflow acts as a scattering mirror changing the apparent spatial properties of the disc. This inflow may be also identified with the broad line region or its inner parts. Results: Such a model is able to explain the basic properties of the apparent disc sizes, primarily their large values and their shallow dependence on wavelength. The only condition required is to scatter a significant portion of the luminosity of the disc. This can easily be fulfilled if the scattering inflow has a large geometrical thickness and clumpy structure.

  14. Spiral-driven accretion in protoplanetary discs . III. Tridimensional simulations

    NASA Astrophysics Data System (ADS)

    Hennebelle, Patrick; Lesur, Geoffroy; Fromang, Sébastien

    2017-03-01

    Context. Understanding how accretion proceeds in proto-planetary discs, and more generally, understanding their dynamics, is a crucial questions that needs to be answered to explain the conditions in which planets form. Aims: The role that accretion of gas from the surrounding molecular cloud onto the disc may have on its structure needs to be quantified. Methods: We performed tridimensional simulations using the Cartesian AMR code RAMSES of an accretion disc that is subject to infalling material. Results: For the aspect ratio of H/R ≃ 0.15 and disc mass Md ≃ 10-2M⊙ used in our study, we find that for typical accretion rates of the order of a few 10-7M⊙ yr-1, values of the α parameter as high as a few 10-3 are inferred. The mass that is accreted in the inner part of the disc is typically at least 50% of the total mass that has been accreted onto the disc. Conclusions: Our results suggest that external accretion of gas at moderate values onto circumstellar discs may trigger prominent spiral arms that are reminiscent of recent observations made with various instruments, and may lead to significant transport through the disc. If confirmed from observational studies, such accretion may therefore influence disc evolution.

  15. Notochord Cells in Intervertebral Disc Development and Degeneration

    PubMed Central

    McCann, Matthew R.; Séguin, Cheryle A.

    2016-01-01

    The intervertebral disc is a complex structure responsible for flexibility, multi-axial motion, and load transmission throughout the spine. Importantly, degeneration of the intervertebral disc is thought to be an initiating factor for back pain. Due to a lack of understanding of the pathways that govern disc degeneration, there are currently no disease-modifying treatments to delay or prevent degenerative disc disease. This review presents an overview of our current understanding of the developmental processes that regulate intervertebral disc formation, with particular emphasis on the role of the notochord and notochord-derived cells in disc homeostasis and how their loss can result in degeneration. We then describe the role of small animal models in understanding the development of the disc and their use to interrogate disc degeneration and associated pathologies. Finally, we highlight essential development pathways that are associated with disc degeneration and/or implicated in the reparative response of the tissue that might serve as targets for future therapeutic approaches. PMID:27252900

  16. The effect of radiative feedback on disc fragmentation

    NASA Astrophysics Data System (ADS)

    Mercer, Anthony; Stamatellos, Dimitris

    2017-02-01

    Protostellar discs may become massive enough to fragment producing secondary low-mass objects: planets, brown dwarfs and low-mass stars. We study the effect of radiative feedback from such newly formed secondary objects using radiative hydrodynamic simulations. We compare the results of simulations without any radiative feedback from secondary objects with those where two types of radiative feedback are considered: (i) continuous and (ii) episodic. We find that (i) continuous radiative feedback stabilizes the disc and suppresses further fragmentation, reducing the number of secondary objects formed; (ii) episodic feedback from secondary objects heats and stabilizes the disc when the outburst occurs, but shortly after the outburst stops, the disc becomes unstable and fragments again. However, fewer secondary objects are formed compared to the case without radiative feedback. We also find that the mass growth of secondary objects is mildly suppressed due to the effect of their radiative feedback. However, their mass growth also depends on where they form in the disc and on their subsequent interactions, such that their final masses are not drastically different from the case without radiative feedback. We find that the masses of secondary objects formed by disc fragmentation are from a few MJ to a few 0.1 M⊙. Planets formed by fragmentation tend to be ejected from the disc. We conclude that planetary-mass objects on wide orbits (wide-orbit planets) are unlikely to form by disc fragmentation. Nevertheless, disc fragmentation may be a significant source of free-floating planets and brown dwarfs.

  17. Fluid management in cardiac surgery patients: pitfalls, challenges and solutions.

    PubMed

    Bignami, Elena; Guarnieri, Marcello; Gemma, Marco

    2017-01-17

    Fluid administration is a powerful tool for hemodynamic stabilization as it increases preload and improves cardiac function in fluid-responsive patients. However, there are various types of fluid to choose from. The use of colloids and crystalloids in non-cardiac Intensive Care Units (ICU) has been reported, showing controversial results. Many trials on sepsis in a non-cardiac ICU setting show that colloids, in particular hydroxyethyl starches and gelatins, might have a detrimental effect on kidney function, and on major outcomes such as mortality. Many small randomized clinical trials focusing on coagulation and bleeding show controversial results regarding fluid safety during the perioperative period in cardiac surgery, and in the cardiac ICU. No definitive data are available on the superiority of one fluid compared with another for fluid replacement after cardiac surgery. Only few data are available regarding the impact of fluids on kidney function in the cardiac ICU. On the other hand, there is much evidence showing that fluid administration requires strict protocols and close monitoring. Improved clinical outcomes are evident in protocols for goal-directed therapy. In conclusion, the application of a close monitoring and a pre-defined goal-directed protocol are far more important than the choice of a single fluid. This review examines the available evidence on fluid management in cardiac surgery and in the ICU, and analyzes the key steps of fluid strategy in these settings.

  18. Teaching Anatomy in the XXI Century: New Aspects and Pitfalls

    PubMed Central

    Papa, Veronica; Vaccarezza, Mauro

    2013-01-01

    Anatomy has historically been a cornerstone in medical education regardless of nation, racial background, or medical school system. By learning gross anatomy, medical students get a first “impression” about the structure of the human body which is the basis for understanding pathologic and clinical problems. Although the importance of teaching anatomy to both undergraduate and postgraduate students remains undisputed, there is currently a relevant debate concerning methods of anatomy teaching. In the past century, dissection and lectures were its sole pedagogy worldwide. Recently, the time allocated for anatomy teaching was dramatically reduced to such an extent that some suggest that it has fallen below an adequate standard. Traditional anatomy education based on topographical structural anatomy taught in lectures and gross dissection classes has been replaced by a multiple range of study modules, including problem-based learning, plastic models or computer-assisted learning, and curricula integration. “Does the anatomical theatre still have a place in medical education?” And “what is the problem with anatomic specimens?” We endeavor to answer both of these questions and to contribute to the debate on the current situation in undergraduate and graduate anatomy education. Doctors without anatomy are like moles.They work in the dark and the work of their hands are mounds. Friedrich TiedemannThe foundation of the study of the art of operating must be laid in the dissecting room. Robert Liston PMID:24367240

  19. Analysis of rabbit intervertebral disc physiology based on water metabolism. II. Changes in normal intervertebral discs under axial vibratory load

    SciTech Connect

    Hirano, N.; Tsuji, H.; Ohshima, H.; Kitano, S.; Itoh, T.; Sano, A.

    1988-11-01

    Metabolic changes induced by axial vibratory load to the spine were investigated based on water metabolism in normal intervertebral discs of rabbits with or without pentobarbital anesthesia. Tritiated water concentration in the intervertebral discs of unanesthetized rabbits was reduced remarkably by axial vibration for 30 minutes using the vibration machine developed for this study. Repeated vibratory load for 18 and 42 hours duration showed the recovery of /sup 3/H/sub 2/O concentration of the intervertebral disc without anesthesia. Computer simulation suggested a reduction of blood flow surrounding the intervertebral disc following the vibration stress. However, no reduction of the /sup 3/H/sub 2/O concentration in the intervertebral disc was noted under anesthesia. Emotional stress cannot be excluded as a factor in water metabolism in the intervertebral disc.

  20. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    PubMed Central

    Harrison, William D.; Harrison, David J.

    2013-01-01

    Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR) is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf. PMID:24294533

  1. Disc and condylar head position in the temporomandibular joint with and without disc displacement.

    PubMed

    Badel, Tomislav; Pavicin, Ivana Savić; Jakovac, Marko; Kern, Josipa; Zadravec, Dijana

    2013-09-01

    The purpose of this study was to evaluate the difference between disc and condyle position between temporomandibular joints (TMJs) without disc displacement (DD) in asymptomatic volunteers, and patients who have DD in contralateral joints, respectively unilateral DD. Secondly, there were two TMJ groups which consisted of measurements from patients' symptomatic DD and volunteers with asymptomatic DD. The study included 79 TMJs of 40 patients with unilateral DD. In the group of 25 asymptomatic volunteers, 20 volunteers were without DD bilaterally (40 joints), while five had DD in at least one TMJ. All subjects were examined clinically and DD was confirmed by magnetic resonance imaging. Left and right TMJs were analysed independently for each participant based on their DD status (symptomatic, asymptomatic, and without DD). All asymptomatic TMJs did not have any clinical signs of TMJ functional abnormalities. There was a significant statistical difference between disc position among TMJs without DD in asymptomatic volunteers and TMJs without DD in patients (p = 0.016). Moreover, no significant differences were found between condyle position in the same groups of joints (p = 0.706). There were no significant differences in the DD position (p = 0.918) or condyle position (p = 0.453) between the group with asymptomatic volunteers' joints and the group with symptomatic patients' joints. There was a significant difference between patient and volunteers' joints without DD: the disc was positioned more anteriorly in patients' joints without DD than in joints of asymptomatic volunteers without DD.

  2. Does condylar height decrease more in temporomandibular joint nonreducing disc displacement than reducing disc displacement?

    PubMed Central

    Hu, Ying-Kai; Yang, Chi; Cai, Xie-Yi; Xie, Qian-Yang

    2016-01-01

    Abstract The aim of the study was to compare condylar height changes of anterior disc displacement with reduction (ADDwR) and anterior disc displacement without reduction (ADDwoR) in temporomandibular joint (TMJ) quantitatively, to get a better understanding of the changes in condylar height of patients with anterior disc displacement who had received no treatment, and to provide useful information for treatment protocol. This longitudinal retrospective study enrolled 206 joints in 156 patients, which were divided into ADDWR group and ADDwoR group based on magnetic resonance imaging examination. The joints were assessed quantitatively for condylar height at initial and follow-up visits. Also, both groups were further divided into 3 subgroups according to age: <15 years group, 15 to 21 years group, and 22 to 35 years group. Paired t test and independent t test were used to assess intra- and intergroup differences. The average age of the ADDwR group was 19.65 years with a mean of 9.47 months’ follow-up. The follow-up interval of the patients with ADDwoR was 7.96 months, with a mean age of 18.51 years. Condylar height in ADDwoR tended to decrease more than those in ADDwR, especially during the pubertal growth spurt and with the presence of osteoarthrosis, meaning ADDwoR could cause a severe disturbance in mandibular development. Thus, an early disc repositioning was suggested to avoid decrease in condylar height. PMID:27583909

  3. Prioritization methodology for chemical replacement

    NASA Technical Reports Server (NTRS)

    Cruit, Wendy; Goldberg, Ben; Schutzenhofer, Scott

    1995-01-01

    Since United States of America federal legislation has required ozone depleting chemicals (class 1 & 2) to be banned from production, The National Aeronautics and Space Administration (NASA) and industry have been required to find other chemicals and methods to replace these target chemicals. This project was initiated as a development of a prioritization methodology suitable for assessing and ranking existing processes for replacement 'urgency.' The methodology was produced in the form of a workbook (NASA Technical Paper 3421). The final workbook contains two tools, one for evaluation and one for prioritization. The two tools are interconnected in that they were developed from one central theme - chemical replacement due to imposed laws and regulations. This workbook provides matrices, detailed explanations of how to use them, and a detailed methodology for prioritization of replacement technology. The main objective is to provide a GUIDELINE to help direct the research for replacement technology. The approach for prioritization called for a system which would result in a numerical rating for the chemicals and processes being assessed. A Quality Function Deployment (QFD) technique was used in order to determine numerical values which would correspond to the concerns raised and their respective importance to the process. This workbook defines the approach and the application of the QFD matrix. This technique: (1) provides a standard database for technology that can be easily reviewed, and (2) provides a standard format for information when requesting resources for further research for chemical replacement technology. Originally, this workbook was to be used for Class 1 and Class 2 chemicals, but it was specifically designed to be flexible enough to be used for any chemical used in a process (if the chemical and/or process needs to be replaced). The methodology consists of comparison matrices (and the smaller comparison components) which allow replacement technology

  4. AIRS Mission Support from GES DISC

    NASA Technical Reports Server (NTRS)

    Wei, Jennifer; Hearty, Thomas; Savtchenko, Audrey; Ding, Feng; Esfandiari, Ed; Theobald, Mike; Vollmer, Bruce; Kempler, Steve

    2015-01-01

    This talk will describe the support and distribution of AIRS (Atmospheric Infra Red Sounding) data products that are archived and distributed from the Goddard Earth Sciences Data and Information Services Center. Along with data stewardship, an important mission of GES DISC is to enhance the usability of data and broaden the user base. We will provide a brief summary of the current online archive and distribution metrics for the AIRS v5 and v6 products. We will also describe collaborative data sets and services (e.g., visualization and potential science applications) and solicit feedback for potential future services.

  5. Development of an Optical Disc Recorder

    DTIC Science & Technology

    1977-02-01

    ILIP S LABORATORIE S rotary air bearing ( Model 4B). The air bearing has been direct- ly coupled to one end of the motor shaft. A 2000-line optical...available for 4 30 rps operation. 4.4 Materials Evaluation A Model 907 He-Ne laser was received from Spectra Physics. Output was found to be 25 mW in...Modulation was provided by a Harris Model 180 acoustoptic modulator. - • Pulse duration was approximately 500 nsec; disc rotation speed was 6 rps . Figure 8

  6. Cell therapy for the degenerating intervertebral disc.

    PubMed

    Tong, Wei; Lu, Zhouyu; Qin, Ling; Mauck, Robert L; Smith, Harvey E; Smith, Lachlan J; Malhotra, Neil R; Heyworth, Martin F; Caldera, Franklin; Enomoto-Iwamoto, Motomi; Zhang, Yejia

    2017-03-01

    Spinal conditions related to intervertebral disc (IVD) degeneration cost billions of dollars in the US annually. Despite the prevalence and soaring cost, there is no specific treatment that restores the physiological function of the diseased IVD. Thus, it is vital to develop new treatment strategies to repair the degenerating IVD. Persons with IVD degeneration without back pain or radicular leg pain often do not require any intervention. Only patients with severe back pain related to the IVD degeneration or biomechanical instability are likely candidates for cell therapy. The IVD progressively degenerates with age in humans, and strategies to repair the IVD depend on the stage of degeneration. Cell therapy and cell-based gene therapy aim to address moderate disc degeneration; advanced stage disease may require surgery. Studies involving autologous, allogeneic, and xenogeneic cells have all shown good survival of these cells in the IVD, confirming that the disc niche is an immunologically privileged site, permitting long-term survival of transplanted cells. All of the animal studies reviewed here reported some improvement in disc structure, and 2 studies showed attenuation of local inflammation. Among the 50 studies reviewed, 25 used some type of scaffold, and cell leakage is a consistently noted problem, though some studies showed reduced cell leakage. Hydrogel scaffolds may prevent cell leakage and provide biomechanical support until cells can become established matrix producers. However, these gels need to be optimized to prevent this leakage. Many animal models have been leveraged in this research space. Rabbit is the most frequently used model (28 of 50), followed by rat, pig, and dog. Sheep and goat IVDs resemble those of humans in size and in the absence of notochordal cells. Despite this advantage, there were only 2 sheep and 1 goat studies of 50 studies in this cohort. It is also unclear if a study in large animals is needed before clinical trials since

  7. Optimization of station battery replacement

    NASA Astrophysics Data System (ADS)

    Jancauskas, J. R.; Shook, D. A.

    1994-08-01

    During a loss of ac power at a nuclear generating station (including diesel generators), batteries provide the source of power which is required to operate safety-related components. Because traditional lead-acid batteries have a qualified life of 20 years, the batteries must be replaced a minimum of once during a station's lifetime, twice if license extension is pursued, and more often depending on actual in-service dates and the results of surveillance tests. Replacement of batteries often occurs prior to 20 years as a result of systems changes caused by factors such as Station Blackout Regulations, control system upgrades, incremental load growth, and changes in the operating times of existing equipment. Many of these replacement decisions are based on the predictive capabilities of manual design basis calculations. The inherent conservatism of manual calculations may result in battery replacements occurring before actually required. Computerized analysis of batteries can aid in optimizing the timing of replacements as well as in interpreting service test data. Computerized analysis also provides large benefits in maintaining the as-configured load profile and corresponding design margins, while also providing the capability to quickly analyze proposed modifications and respond to internal and external audits.

  8. Replacement of outboard main steam isolation valves in a boiling water reactor plant

    SciTech Connect

    Schlereth, J.R.; Pennington, D.

    1996-12-01

    Most Boiling Water Reactor plants utilize wye pattern globe valves for main steam isolation valves for both inboard and outboard isolation. These valves have required a high degree of maintenance attention in order to pass the plant local leakage rate testing (LLRT) requirements at each outage. Northern States Power made a decision in 1993 to replace the outboard valves at it`s Monticello plant with double disc gate valves. The replacement of the outboard valves was completed during the fall outage in 1994. During the spring outage in April of 1996 the first LLRT testing was performed with excellent results. This presentation will address the decision process, time requirements and planning necessary to accomplish the task as well as the performance results and cost effectiveness of replacing these components.

  9. [Hip replacement in military personnel].

    PubMed

    Maksimov, I B; Paniushin, K A; Brizhan', L K; Buriachenko, B P; Varfolomeev, D I; Mimanchev, O V

    2014-01-01

    Hip joint diseases and injuries are common for orthopedic pathology among military personnel. Hip replacement is one of the most frequent operations. Authors evaluated hip replacement in 136 servicemen treated at the center of traumatology and orthopedics of Burdenko General Military Clinical Hospital of the Ministry of Defense of Russia in 2010-2013. On the basis of the conducted analysis the main disease groups were revealed, peculiarities of pathology among this category of patients. Authors proposed surgical doctrine for the treatment of this contingent. Effective surgical treatment, in particular, hip replacement surgery, conducted with the use of the proposed principles, as a rule, fully functionally cured patients and contributes to return them in the system that contributes to the strengthening of defensibility of the country.

  10. HST Replacement Battery Initial Performance

    NASA Technical Reports Server (NTRS)

    Krol, Stan; Waldo, Greg; Hollandsworth, Roger

    2009-01-01

    The Hubble Space Telescope (HST) original Nickel-Hydrogen (NiH2) batteries were replaced during the Servicing Mission 4 (SM4) after 19 years and one month on orbit.The purpose of this presentation is to highlight the findings from the assessment of the initial sm4 replacement battery performance. The batteries are described, the 0 C capacity is reviewed, descriptions, charts and tables reviewing the State Of Charge (SOC) Performance, the Battery Voltage Performance, the battery impedance, the minimum voltage performance, the thermal performance, the battery current, and the battery system recharge ratio,

  11. Prioritization methodology for chemical replacement

    NASA Technical Reports Server (NTRS)

    Goldberg, Ben; Cruit, Wendy; Schutzenhofer, Scott

    1995-01-01

    This methodology serves to define a system for effective prioritization of efforts required to develop replacement technologies mandated by imposed and forecast legislation. The methodology used is a semi quantitative approach derived from quality function deployment techniques (QFD Matrix). QFD is a conceptual map that provides a method of transforming customer wants and needs into quantitative engineering terms. This methodology aims to weight the full environmental, cost, safety, reliability, and programmatic implications of replacement technology development to allow appropriate identification of viable candidates and programmatic alternatives.

  12. The jet-disc connection in AGN

    NASA Astrophysics Data System (ADS)

    Sbarrato, T.; Padovani, P.; Ghisellini, G.

    2014-11-01

    We present our latest results on the connection between accretion rate and relativistic jet power in active galactic nuclei (AGN), by using a large sample which includes mostly blazars, but contains also some radio galaxies. The jet power can be traced by γ-ray luminosity in the case of blazars, and radio luminosity for both classes. The accretion-disc luminosity is instead traced by the broad emission lines. Among blazars, we find a correlation between broad line emission and the γ-ray or radio luminosities, suggesting a direct tight connection between jet power and accretion rate. We confirm that the observational differences between blazar subclasses reflect differences in the accretion regime, but with blazars only we cannot properly access the low-accretion regime. By introducing radio galaxies, we succeed in observing the fingerprint of the transition between radiatively efficient and inefficient accretion discs in the jetted AGN family. The transition occurs at the standard critical value Ld/LEdd ˜ 10-2 and it appears smooth. Below this value, the ionizing luminosity emitted by the accretion structure drops significantly.

  13. Bulk Comptonization by turbulence in accretion discs

    NASA Astrophysics Data System (ADS)

    Kaufman, J.; Blaes, O. M.

    2016-06-01

    Radiation pressure dominated accretion discs around compact objects may have turbulent velocities that greatly exceed the electron thermal velocities within the disc. Bulk Comptonization by the turbulence may therefore dominate over thermal Comptonization in determining the emergent spectrum. Bulk Comptonization by divergenceless turbulence is due to radiation viscous dissipation only. It can be treated as thermal Comptonization by solving the Kompaneets equation with an equivalent `wave' temperature, which is a weighted sum over the power present at each scale in the turbulent cascade. Bulk Comptonization by turbulence with non-zero divergence is due to both pressure work and radiation viscous dissipation. Pressure work has negligible effect on photon spectra in the limit of optically thin turbulence, and in this limit radiation viscous dissipation alone can be treated as thermal Comptonization with a temperature equivalent to the full turbulent power. In the limit of extremely optically thick turbulence, radiation viscous dissipation is suppressed, and the evolution of local photon spectra can be understood in terms of compression and expansion of the strongly coupled photon and gas fluids. We discuss the consequences of these effects for self-consistently resolving and interpreting turbulent Comptonization in spectral calculations in radiation magnetohydrodynamic simulations of high luminosity accretion flows.

  14. Genetic Factors in Intervertebral Disc Degeneration

    PubMed Central

    Feng, Yi; Egan, Brian; Wang, Jinxi

    2016-01-01

    Low back pain (LBP) is a major cause of disability and imposes huge economic burdens on human society worldwide. Among many factors responsible for LBP, intervertebral disc degeneration (IDD) is the most common disorder and is a target for intervention. The etiology of IDD is complex and its mechanism is still not completely understood. Many factors such as aging, spine deformities and diseases, spine injuries, and genetic factors are involved in the pathogenesis of IDD. In this review, we will focus on the recent advances in studies on the most promising and extensively examined genetic factors associated with IDD in humans. A number of genetic defects have been correlated with structural and functional changes within the intervertebral disc (IVD), which may compromise the disc’s mechanical properties and metabolic activities. These genetic and proteomic studies have begun to shed light on the molecular basis of IDD, suggesting that genetic factors are important contributors to the onset and progression of IDD. By continuing to improve our understanding of the molecular mechanisms of IDD, specific early diagnosis and more effective treatments for this disabling disease will be possible in the future. PMID:27617275

  15. The cellular memory disc of reprogrammed cells.

    PubMed

    Anjamrooz, Seyed Hadi

    2013-04-01

    The crucial facts underlying the low efficiency of cellular reprogramming are poorly understood. Cellular reprogramming occurs in nuclear transfer, induced pluripotent stem cell (iPSC) formation, cell fusion, and lineage-switching experiments. Despite these advances, there are three fundamental problems to be addressed: (1) the majority of cells cannot be reprogrammed, (2) the efficiency of reprogramming cells is usually low, and (3) the reprogrammed cells developed from a patient's own cells activate immune responses. These shortcomings present major obstacles for using reprogramming approaches in customised cell therapy. In this Perspective, the author synthesises past and present observations in the field of cellular reprogramming to propose a theoretical picture of the cellular memory disc. The current hypothesis is that all cells undergo an endogenous and exogenous holographic memorisation such that parts of the cellular memory dramatically decrease the efficiency of reprogramming cells, act like a barrier against reprogramming in the majority of cells, and activate immune responses. Accordingly, the focus of this review is mainly to describe the cellular memory disc (CMD). Based on the present theory, cellular memory includes three parts: a reprogramming-resistance memory (RRM), a switch-promoting memory (SPM) and a culture-induced memory (CIM). The cellular memory arises genetically, epigenetically and non-genetically and affects cellular behaviours. [corrected].

  16. Risk Factors for Recurrent Lumbar Disc Herniations

    PubMed Central

    2014-01-01

    The most common complication after lumbar discectomy is reherniation. As the first step in reducing the rate of recurrence, many studies have been conducted to find out the factors that may increase the reherniation risk. Some reported factors are age, sex, the type of lumbar disc herniation, the amount of fragments removed, smoking, alcohol consumption and the length of restricted activities. In this review, the factors studied thus far are summarized, excepting factors which cannot be chosen or changed, such as age or sex. Apart from the factors shown here, many other risk factors such as diabetes, family history, history of external injury, duration of illness and body mass index are considered. Few are agreed upon by all. The reason for the diverse opinions may be that many clinical and biomechanical variables are involved in the prognosis following operation. For the investigation of risk factors in recurrent lumbar disc herniation, large-scale multicenter prospective studies will be required in the future. PMID:24761206

  17. Multi-center, Prospective, Randomized, Controlled Investigational Device Exemption Clinical Trial Comparing Mobi-C Cervical Artificial Disc to Anterior Discectomy and Fusion in the Treatment of Symptomatic Degenerative Disc Disease in the Cervical Spine

    PubMed Central

    Bae, Hyun W.; Davis, Reginald; Gaede, Steven; Hoffman, Greg; Kim, Kee; Nunley, Pierce D.; Peterson, Daniel; Rashbaum, Ralph; Stokes, John

    2014-01-01

    Background Anterior cervical discectomy and fusion (ACDF) is the gold standard for treating symptomatic cervical disc degeneration. Cervical total disc replacements (TDRs) have emerged as an alternative for some patients. The purpose of this study was to evaluate the safety and effectiveness of a new TDR device compared with ACDF for treating single-level cervical disc degeneration. Methods This was a prospective, randomized, controlled, multicenter Food and Drug Administration (FDA) regulated Investigational Device Exemption (IDE) study. A total of 245 patients were treated (164 TDR: 81 ACDF). The primary outcome measure was overall success based on improvement in Neck Disability Index (NDI), no subsequent surgical interventions, and no adverse events (AEs) classified as major complications. Secondary outcome measures included SF-12, visual analog scale (VAS) assessing neck and arm pain, patient satisfaction, radiographic range of motion, and adjacent level degeneration. Patients were evaluated preoperatively and postoperatively at 6 weeks, 3, 6, 12, 18, and 24 months. The hypothesis was that the TDR success rate was non-inferior to ACDF at 24 months. Results Overall success rates were 73.6% for TDR and 65.3% for ACDF, confirming non-inferiority (p < 0.0025). TDR demonstrated earlier improvements with significant differences in NDI scores at 6 weeks and 3 months, and VAS neck pain and SF-12 PCS scores at 6 weeks (p<0.05). Operative level range of motion in the TDR group was maintained throughout follow-up. Radiographic evidence of inferior adjacent segment degeneration was significantly greater with ACDF at 12 and 24 months (p < 0.05). AE rates were similar. Conclusions Mobi-C TDR is a safe and effective treatment for single-level disc degeneration, producing outcomes similar to ACDF with less adjacent segment degeneration. Level of Evidence: Level I. Clinical relevance: This study adds to the literature supporting cervical TDR as a viable option to ACDF in

  18. Early results and review of the literature of a novel hybrid surgical technique combining cervical arthrodesis and disc arthroplasty for treating multilevel degenerative disc disease: opposite or complementary techniques?

    PubMed Central

    Assietti, Roberto; Corbino, Leonardo; Olindo, Giuseppe; Foti, Pietro V.; Russo, Vittorio; Albanese, Vincenzo

    2009-01-01

    We report the clinical and radiological results on the safety and efficacy of an unusual surgical strategy coupling anterior cervical discectomy and fusion and total disc replacement in a single-stage procedure, in patients with symptomatic, multilevel cervical degenerative disc disease (DDD). The proposed hybrid, single-stage, fusion–nonfusion technique aims either at restoring or maintaining motion where appropriate or favouring bony fusion when indicated by degenerative changes. Twenty-four patients (mean age 46.7 years) with symptomatic, multilevel DDD, either soft disc hernia or different stage spondylosis per single level, with predominant anterior myeloradicular compression and absence of severe alterations of cervical spine sagittal alignment, have been operated using such hybrid technique. Fifteen patients underwent a two-level surgery, seven patients received a three-level surgery and two a four-level procedure, for a total of 59 implanted devices (27 disc prostheses and 32 cages). Follow-up ranged between 12 and 40 months (mean 23.8 months). In all but one patient clinical follow-up (neurological examination, Nurick scale, NDI, SF-36) demonstrated significant improvement; radiological evaluation showed functioning disc prostheses (total range of motion 3–15°) and fusion through cages. None of the patients needed revision surgery for persisting or recurring symptoms, procedure-related complications or devices dislocations. To the authors’ best knowledge, this is the first study with the longest available follow-up describing a different concept in the management of cervical multilevel DDD. Although larger series with longer follow-up are needed, in selected cases of symptomatic multilevel DDD, the proposed surgical strategy appears to be a safe and reliable application of combined arthroplasty and arthrodesis during a single surgical procedure. PMID:19415346

  19. The comparative analysis of rocks' resistance to forward-slanting disc cutters and traditionally installed disc cutters

    NASA Astrophysics Data System (ADS)

    Zhang, Zhao-Huang; Fei, Sun; Liang, Meng

    2016-08-01

    At present, disc cutters of a full face rock tunnel boring machine are mostly mounted in the traditional way. Practical use in engineering projects reveals that this installation method not only heavily affects the operation life of disc cutters, but also increases the energy consumption of a full face rock tunnel boring machine. To straighten out this issue, therefore, a rock-breaking model is developed for disc cutters' movement after the research on the rock breaking of forward-slanting disc cutters. Equations of its displacement are established based on the analysis of velocity vector of a disc cutter's rock-breaking point. The functional relations then are brought forward between the displacement parameters of a rock-breaking point and its coordinate through the analysis of micro displacement of a rock-breaking point. Thus, the geometric equations of rock deformation are derived for the forward-slanting installation of disc cutters. With a linear relationship remaining between the acting force and its deformation either before or after the leap breaking, the constitutive relation of rock deformation can be expressed in the form of generalized Hooke law, hence the comparative analysis of the variation in the resistance of rock to the disc cutters mounted in the forward-slanting way with that in the traditional way. It is discovered that with the same penetration, strain of the rock in contact with forward-slanting disc cutters is apparently on the decline, in other words, the resistance of rock to disc cutters is reduced. Thus wear of disc cutters resulted from friction is lowered and energy consumption is correspondingly decreased. It will be useful for the development of installation and design theory of disc cutters, and significant for the breakthrough in the design of full face rock tunnel boring machine.

  20. Tissue Engineering a Biological Repair Strategy for Lumbar Disc Herniation

    PubMed Central

    O'Connell, Grace D.; Leach, J. Kent; Klineberg, Eric O.

    2015-01-01

    Abstract The intervertebral disc is a critical part of the intersegmental soft tissue of the spinal column, providing flexibility and mobility, while absorbing large complex loads. Spinal disease, including disc herniation and degeneration, may be a significant contributor to low back pain. Clinically, disc herniations are treated with both nonoperative and operative methods. Operative treatment for disc herniation includes removal of the herniated material when neural compression occurs. While this strategy may have short-term advantages over nonoperative methods, the remaining disc material is not addressed and surgery for mild degeneration may have limited long-term advantage over nonoperative methods. Furthermore, disc herniation and surgery significantly alter the mechanical function of the disc joint, which may contribute to progression of degeneration in surrounding tissues. We reviewed recent advances in tissue engineering and regenerative medicine strategies that may have a significant impact on disc herniation repair. Our review on tissue engineering strategies focuses on cell-based and inductive methods, each commonly combined with material-based approaches. An ideal clinically relevant biological repair strategy will significantly reduce pain and repair and restore flexibility and motion of the spine. PMID:26634189

  1. On the formation of planetary systems in photoevaporating transition discs

    NASA Astrophysics Data System (ADS)

    Terquem, Caroline

    2017-01-01

    In protoplanetary discs, planetary cores must be at least 0.1 M⊕ at 1 au for migration to be significant; this mass rises to 1 M⊕ at 5 au. Planet formation models indicate that these cores form on million year time-scales. We report here a study of the evolution of 0.1 and 1 M⊕ cores, migrating from about 2 and 5 au, respectively, in million year old photoevaporating discs. In such a disc, a gap opens up at around 2 au after a few million years. The inner region subsequently accrete on to the star on a smaller time-scale. We find that, typically, the smallest cores form systems of non-resonant planets beyond 0.5 au with masses up to about 1.5 M⊕. In low-mass discs, the same cores may evolve in situ. More massive cores form systems of a few Earth-mass planets. They migrate within the inner edge of the disc gap only in the most massive discs. Delivery of material to the inner parts of the disc ceases with opening of the gap. Interestingly, when the heavy cores do not migrate significantly, the type of systems that are produced resembles our Solar system. This study suggests that low-mm flux transition discs may not form systems of planets on short orbits but may instead harbour Earth-mass planets in the habitable zone.

  2. Dust dynamics in 2D gravito-turbulent discs

    NASA Astrophysics Data System (ADS)

    Shi, Ji-Ming; Zhu, Zhaohuan; Stone, James M.; Chiang, Eugene

    2016-06-01

    The dynamics of solid bodies in protoplanetary discs are subject to the properties of any underlying gas turbulence. Turbulence driven by disc self-gravity shows features distinct from those driven by the magnetorotational instability (MRI). We study the dynamics of solids in gravito-turbulent discs with two-dimensional (in the disc plane), hybrid (particle and gas) simulations. Gravito-turbulent discs can exhibit stronger gravitational stirring than MRI-active discs, resulting in greater radial diffusion and larger eccentricities and relative speeds for large particles (those with dimensionless stopping times tstopΩ > 1, where Ω is the orbital frequency). The agglomeration of large particles into planetesimals by pairwise collisions is therefore disfavoured in gravito-turbulent discs. However, the relative speeds of intermediate-size particles (tstopΩ ˜ 1) are significantly reduced as such particles are collected by gas drag and gas gravity into coherent filament-like structures with densities high enough to trigger gravitational collapse. First-generation planetesimals may form via gravitational instability of dust in marginally gravitationally unstable gas discs.

  3. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc...

  4. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Interarticular disc prosthesis (interpositional implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Food and Drug Administration on or before March 30, 1999, for any interarticular disc...

  5. RADIOLOGICAL ANALYSIS OF EXPERIMENTAL DISC DEGENERATION IN RABBITS

    PubMed Central

    Vialle, Emiliano; Vialle, Luiz Roberto; Arruda, André de Oliveira; Riet, Ricardo Nascimento; Krieger, Antônio Bernardo de Queiroz

    2015-01-01

    Objective: To validate radiographic evaluation of a rabbit model for disc degeneration. Methods: Lumbar intervertebral discs of New Zealand rabbits were stabbed three times with a 18G needle at a limited depth of 5mm, through lateral approach. Serial radiographic images were taken on the early pre-and postoperative periods, and after four, eight and 12 weeks of the procedure, with subsequent analysis of disc height, osteophyte formation, endplate sclerosis, and presence of disc degeneration. The statistical analysis of data was validated by the Kappa coefficient, with a confidence interval (CI) of 95%. Results: A significant reduction of disc space was found on AP X-ray images after 12 postoperative weeks, with Kappa = 0.489 for CI 95% (0.25-0.72) with p < 0.001. X-ray signs of disc degeneration also presented Kappa = 0.63 for CI 95% (0.39-0.86) with p < 0.001. The remaining assessed criteria showed positive results, but with a lower Kappa value. Conclusion: The disc degeneration model using rabbits as proposed in this study was shown to be feasible, with positive X-ray correlation between pre- and postoperative images, validating the potential to induce disc degeneration in this animal model for future studies. PMID:27022512

  6. Angiogenesis in the degeneration of the lumbar intervertebral disc

    PubMed Central

    David, Gh; Iencean, SM; Mohan, A

    2010-01-01

    The goal of the study is to show the histological and biochemical changes that indicate the angiogenesis of the intervertebral disc in lumbar intervertebral disc hernia and the existence of epidemiological correlations between these changes and the risk factors of lumbar intervertebral disc hernia, as well as the patient's quality of life (QOL). We have studied 50 patients aged between 18 and 73 years old, who have undergone lumbar intervertebral disc hernia surgery, making fibroblast growth factor and vascular endothelial growth factor level measurements, as elements in the process of appreciating the disc angiogenesis. Also, pre–surgery and post–surgery QOL has been measured, as well as the intensity of the pain syndrome. We have identified factors capable of stimulating vascular endothelial growth (VEGF, FGF–2) for the examined disc material, but histological examination did not show angiogenesis. The process of angiogenesis at the degenerated intervertebral disc level affects the patient's quality of life both pre and postoperatively, and may be a predictive factor for the post–operative results. Patients can prevent the appearance of angiogenesis type degenerative processes of the intervertebral disc by avoiding angiogenesis correlated factors (weight control, physical effort, and smoking). PMID:20968201

  7. Goddard Earth Science Data and Information Center (GES DISC)

    NASA Technical Reports Server (NTRS)

    Kempler, Steve

    2016-01-01

    The GES DIS is one of 12 NASA Earth science data centers. The GES DISC vision is to enable researchers and educators maximize knowledge of the Earth by engaging in understanding their goals, and by leading the advancement of remote sensing information services in response to satisfying their goals. This presentation will describe the GES DISC approach, successes, challenges, and best practices.

  8. Elastic, permeability and swelling properties of human intervertebral disc tissues: A benchmark for tissue engineering.

    PubMed

    Cortes, Daniel H; Jacobs, Nathan T; DeLucca, John F; Elliott, Dawn M

    2014-06-27

    The aim of functional tissue engineering is to repair and replace tissues that have a biomechanical function, i.e., connective orthopaedic tissues. To do this, it is necessary to have accurate benchmarks for the elastic, permeability, and swelling (i.e., biphasic-swelling) properties of native tissues. However, in the case of the intervertebral disc, the biphasic-swelling properties of individual tissues reported in the literature exhibit great variation and even span several orders of magnitude. This variation is probably caused by differences in the testing protocols and the constitutive models used to analyze the data. Therefore, the objective of this study was to measure the human lumbar disc annulus fibrosus (AF), nucleus pulposus (NP), and cartilaginous endplates (CEP) biphasic-swelling properties using a consistent experimental protocol and analyses. The testing protocol was composed of a swelling period followed by multiple confined compression ramps. To analyze the confined compression data, the tissues were modeled using a biphasic-swelling model, which augments the standard biphasic model through the addition of a deformation-dependent osmotic pressure term. This model allows considering the swelling deformations and the contribution of osmotic pressure in the analysis of the experimental data. The swelling stretch was not different between the disc regions (AF: 1.28±0.16; NP: 1.73±0.74; CEP: 1.29±0.26), with a total average of 1.42. The aggregate modulus (Ha) of the extra-fibrillar matrix was higher in the CEP (390kPa) compared to the NP (100kPa) or AF (30kPa). The permeability was very different across tissue regions, with the AF permeability (64 E(-16)m(4)/Ns) higher than the NP and CEP (~5.5 E(-16)m(4)/Ns). Additionally, a normalized time-constant (3000s) for the stress relaxation was similar for all the disc tissues. The properties measured in this study are important as benchmarks for tissue engineering and for modeling the disc's mechanical

  9. Will peanut hulls replace oil

    SciTech Connect

    Not Available

    1980-12-01

    A low-cost, fast-curing wood adhesive has been recently developed by the University of Georgia, in which up to 80% of the petroleum ingredients can be replaced with a substance extracted from peanut hulls. An outline of the process is given.

  10. Replaceable Sleeve Protects Welder Coil

    NASA Technical Reports Server (NTRS)

    Baker, W. L.; Simpson, C., E.

    1983-01-01

    New replaceable carbon insert for deflection coil in electron-beam welder promises to decrease maintenance costs. Inserts made from materials other than carbon (not yet tried) are less expensive, thus reducing costs even further. With carbon insert, deflection coils last longer and are easier to maintain.

  11. Analytical Investigation on Squeal Phenomena Generated in Bicycle Disc Brakes

    NASA Astrophysics Data System (ADS)

    Nakae, Takashi; Sueoka, Atsuo; Ryu, Takahiro

    The squeal phenomenon is often generated in bicycle disc brakes. This paper deals analytically with the generation mechanism and the criterion of whether or not the squeal occurs. According to the experimental studies, it has been made clear that the squeal is mainly in-plane vibration in the direction of disc surface with the frequency about 1kHz caused by frictional characteristics with negative slope with respect to the relative velocity. An analytical model of the bicycle disc brake system has been devised to confirm the experimental results, in which a coupled in-plane and out-of-plane vibrating system is composed of the disc, hub, caliper and spokes. The resulting frequency of squeal and the unstable vibration modes of the disc and spokes from the analytical model agreed well with the experimental results.

  12. [L1-2 lumbar disc herniation: a case report].

    PubMed

    Monobe, T; Fujita, T; Nakaue, Y; Nishi, N

    1996-03-01

    A 49-year-old female presented a two-year history of pain in the right thigh and lower back. Neurological examination on admission demonstrated weakness of the right iliopsoas and quadriceps, hypesthesia on the right L1-2 dermatome. Radiological examination including myelography, CT myelography and discography disclosed an L1-2 herniated disc. Sagittal MRI also revealed an L1-2, an L4-5 and L5-S1 protruded disc. A posterior microdiscectomy (Love's method) was performed for the L1-2 disc. A controlateral protruded disc which compressed the L-2 nerve root was identified and partially removed. The postoperative myelography showed residual disc. The patient was free from pain and regained normal sensorimotor function. Love's posterior microdiscectomy has a disadvantage in that the operative field is limited. Careful surgical procedure was needed to avoid injury to nerve roots and the cauda equina in a tight L1-2 lumbar canal.

  13. Spirals, gaps, cavities, gapities: What do planets do in discs?

    NASA Astrophysics Data System (ADS)

    Crida, A.

    2016-12-01

    In this presentation, part of the "Observations of discs" workshop, I address the theoretical point of view of planet-disc interactions. In section 2, I will review the physics of spirals, and explain why the inner and the outer wake created by a planet in a gaseous keplerian disc look very different, but their shape is independant of the mass of the planet and almost only depends on the aspect ratio of the disc. In the third section, I discuss the axisymmetric features (gaps and cavities), and how they differ in the gas or the dust component. However, to start with, some clarification of the nomenclature seems to be required, as observers and theorists may have a different idea of what a gap is. The definition of a "gapity" may help to clarify the situation of pre-transitional discs.

  14. Effectiveness and biases of Winkler litter extraction and pitfall trapping for collecting ground-dwelling ants in northern temperate forests.

    PubMed

    Ivanov, Kaloyan; Keiper, Joe

    2009-12-01

    The sampling efficiency of pitfall traps and Winkler litter extraction in northern deciduous forests was compared using ants. Both techniques are among the most common methods used to measure the diversity of organisms active on the forest floor. During 2005-2006, 90 Winkler and 180 pitfall trap samples from urban forest fragments in northeastern Ohio obtained 9,203 ants representing 31 species. Winklers captured all 31 species, whereas pitfall traps collected a total of 24 species. Winkler samples accumulated species more rapidly than did pitfall traps and had greater total species richness and higher abundance of ants recorded. Consistent with other studies, Winkler sampling was found to catch a greater number of smaller ants, whereas pitfall trapping caught a greater number of large-bodied ants. According to estimates of expected species richness, the combination of the two sampling techniques allowed for the collection of approximately 90% of the ants expected in the surveyed area. Site variation had little effect on the inherent differences in sampling efficacy between the two methods. Either technique adequately collected samples for broad comparisons and documentation of the more typical and representative ant fauna, but Winkler extraction exhibited the advantage of a more complete inventory. The application of both techniques should be considered if the aims of a study require estimation of community properties, such as relative abundance.

  15. Lumbar intervertebral disc degeneration and related factors in Korean firefighters

    PubMed Central

    Jang, Tae-Won; Ahn, Yeon-Soon; Byun, Junsu; Lee, Jong-In; Kim, Kun-Hyung; Kim, Youngki; Song, Han-Soo; Lee, Chul-Gab; Kwon, Young-Jun; Yoon, Jin-Ha; Jeong, Kyoungsook

    2016-01-01

    Objectives The job of firefighting can cause lumbar burden and low back pain. This study aimed to identify the association between age and lumbar intervertebral disc degeneration and whether the association differs between field and administrative (non-field) firefighters. Methods Subjects were selected using a stratified random sampling method. Firefighters were stratified by geographic area, gender, age and type of job. First, 25 fire stations were randomly sampled considering regional distribution. Then firefighters were stratified by gender, age and their job and randomly selected among the strata. A questionnaire survey and MRI scans were performed, and then four radiologists used Pfirrmann classification methods to determine the grade of lumbar intervertebral disc degeneration. Results Pfirrmann grade increased with lumbar intervertebral disc level. Analysis of covariance showed that age was significantly associated with lumbar intervertebral disc degeneration (p<0.05). The value of β (parameter estimate) was positive at all lumbar intervertebral disc levels and was higher in the field group than in the administrative group at each level. In logistic regression analysis, type of job was statistically significant only with regard to the L4–5 intervertebral disc (OR 3.498, 95% CI 1.241 to 9.860). Conclusions Lumbar intervertebral disc degeneration is associated with age, and field work such as firefighting, emergency and rescue may accelerate degeneration in the L4–5 intervertebral disc. The effects of field work on lumbar intervertebral disc degeneration were not clear in discs other than at the level L4–5. PMID:27354080

  16. Molecular Mechanisms of Biological Aging in Intervertebral Discs

    PubMed Central

    Vo, Nam V.; Hartman, Robert A.; Patil, Prashanti R.; Risbud, Makarand V.; Kletsas, Dimitris; Iatridis, James C.; Hoyland, Judith A.; Le Maitre, Christine L.; Sowa, Gwendolyn A.; Kang, James D.

    2016-01-01

    Advanced age is the greatest risk factor for the majority of human ailments, including spine-related chronic disability and back pain, which stem from age-associated intervertebral disc degeneration (IDD). Given the rapid global rise in the aging population, understanding the biology of intervertebral disc aging in order to develop effective therapeutic interventions to combat the adverse effects of aging on disc health is now imperative. Fortunately, recent advances in aging research have begun to shed light on the basic biological process of aging. Here we review some of these insights and organize the complex process of disc aging into three different phases to guide research efforts to understand the biology of disc aging. The objective of this review is to provide an overview of the current knowledge and the recent progress made to elucidate specific molecular mechanisms underlying disc aging. In particular, studies over the last few years have uncovered cellular senescence and genomic instability as important drivers of disc aging. Supporting evidence comes from DNA repair-deficient animal models that show increased disc cellular senescence and accelerated disc aging. Additionally, stress-induced senescent cells have now been well documented to secrete catabolic factors, which can negatively impact the physiology of neighboring cells and ECM. These along with other molecular drivers of aging are reviewed in depth to shed crucial insights into the underlying mechanisms of age-related disc degeneration. We also highlight molecular targets for novel therapies and emerging candidate therapeutics that may mitigate age-associated IDD. PMID:26890203

  17. Structure of radiation-dominated gravitoturbulent quasar discs

    NASA Astrophysics Data System (ADS)

    Shadmehri, Mohsen; Khajenabi, Fazeleh; Dib, Sami

    2017-02-01

    Self-gravitating accretion discs in a gravitoturbulent state, including radiation and gas pressures, are studied using a set of new analytical solutions. While the Toomre parameter of the disc remains close to its critical value for the onset of gravitational instability, the dimensionless stress parameter is uniquely determined from the thermal energy reservoir of the disc and its cooling rate. Our solutions are applicable to the accretion discs with dynamically important radiation pressure such as that in the quasars discs. We show that physical quantities of a gravitoturbulent disc in the presence of radiation are significantly modified compared to solutions with only gas pressure. We show that the dimensionless stress parameter is an increasing function of the radial distance so that its steepness strongly depends on the accretion rate. In a disc without radiation its slope is 4.5; however, we show that in the presence of radiation, it varies between 2 and 4.5 depending on the accretion rate and the central mass. As for the surface density, we find a shallower profile with an exponent -2 in a disc with sub-Eddington accretion rate compared to a similar disc, but without radiation, where its surface density slope is -3 independent of the accretion rate. We then investigate gravitational stability of the disc when the stress parameter reaches to its critical value. In order to self-consistently determine the fragmentation boundary, however, it is shown that the critical value of the stress parameter is a power-law function of the ratio of gas pressure and the total pressure and its exponent is around 1.7. We also estimate the maximum mass of the central black hole using our analytical solutions.

  18. The structure of protoplanetary discs around evolving young stars

    NASA Astrophysics Data System (ADS)

    Bitsch, Bertram; Johansen, Anders; Lambrechts, Michiel; Morbidelli, Alessandro

    2015-03-01

    The formation of planets with gaseous envelopes takes place in protoplanetary accretion discs on time scales of several million years. Small dust particles stick to each other to form pebbles, pebbles concentrate in the turbulent flow to form planetesimals and planetary embryos and grow to planets, which undergo substantial radial migration. All these processes are influenced by the underlying structure of the protoplanetary disc, specifically the profiles of temperature, gas scale height, and density. The commonly used disc structure of the minimum mass solar nebula (MMSN) is a simple power law in all these quantities. However, protoplanetary disc models with both viscous and stellar heating show several bumps and dips in temperature, scale height, and density caused by transitions in opacity, which are missing in the MMSN model. These play an important role in the formation of planets, since they can act as sweet spots for forming planetesimals via the streaming instability and affect the direction and magnitude of type-I migration. We present 2D simulations of accretion discs that feature radiative cooling and viscous and stellar heating, and they are linked to the observed evolutionary stages of protoplanetary discs and their host stars. These models allow us to identify preferred planetesimal and planet formation regions in the protoplanetary disc as a function of the disc's metallicity, accretion rate, and lifetime. We derive simple fitting formulae that feature all structural characteristics of protoplanetary discs during the evolution of several Myr. These fits are straightforward for applying to modelling any growth stage of planets where detailed knowledge of the underlying disc structure is required. Appendix A is available in electronic form at http://www.aanda.org

  19. Gas Modelling in the Disc of HD 163296

    NASA Technical Reports Server (NTRS)

    Tilling, I.; Woitke, P.; Meeus, G.; Mora, A.; Montesinos, B.; Riviere-Marichalar, P.; Eiroa, C.; Thi, W. -F.; Isella, A.; Roberge, A.; Martin-Zaidi, C.; Kamp, I.; Pinte, C.; Sandell, G.; Vacca, W. D.; Menard, F.; Mendigutia, I.; Duchene, G.; Dent, W. R. F.; Aresu, G.; Meijerink, R.; Spaans, M.

    2011-01-01

    We present detailed model fits to observations of the disc around the Herbig Ae star HD 163296. This well-studied object has an age of approx. 4Myr, with evidence of a circumstellar disc extending out to approx. 540AU. We use the radiation thermo-chemical disc code ProDiMo to model the gas and dust in the circumstellar disc of HD 163296, and attempt to determine the disc properties by fitting to observational line and continuum data. These include new Herschel/PACS observations obtained as part of the open-time key program GASPS (Gas in Protoplanetary Systems), consisting of a detection of the [Oi] 63 m line and upper limits for several other far infrared lines. We complement this with continuum data and ground-based observations of the CO-12 3-2, 2-1 and CO-13 J=1-0 line transitions, as well as the H2 S(1) transition. We explore the effects of stellar ultraviolet variability and dust settling on the line emission, and on the derived disc properties. Our fitting efforts lead to derived gas/dust ratios in the range 9-100, depending on the assumptions made. We note that the line fluxes are sensitive in general to the degree of dust settling in the disc, with an increase in line flux for settled models. This is most pronounced in lines which are formed in the warm gas in the inner disc, but the low excitation molecular lines are also affected. This has serious implications for attempts to derive the disc gas mass from line observations. We derive fractional PAH abundances between 0.007 and 0.04 relative to ISM levels. Using a stellar and UV excess input spectrum based on a detailed analysis of observations, we find that the all observations are consistent with the previously assumed disc geometry

  20. Changes in disc status in the reducing and nonreducing anterior disc displacement of temporomandibular joint: a longitudinal retrospective study.

    PubMed

    Hu, Ying Kai; Yang, Chi; Xie, Qian Yang

    2016-09-27

    Treatment procedures for anterior disc displacement (ADD) of temporomandibular joint (TMJ) are far from reaching a consensus. The aim of the study was to evaluate disc status changes of anterior disc displacement with reduction (ADDWR) and without reduction (ADDWoR) comparatively, to get a better understanding of the disease progress without intervention. This longitudinal retrospective study included 217 joints in 165 patients, which were divided into ADDWR group and ADDWoR group based on magnetic resonance imaging (MRI) examination. The joints were assessed quantitatively for disc length and displacement distance at initial and follow-up visits. Disc morphology, which was classified in 5 types, was also evaluated. Paired t-test and Wilcoxon signed rank test were used to assess intra-group differences and independent t-test for inter-group differences. Moreover, analysis of covariance was applied to analyze influential factors for changes in disc length and displacement distance. According to our results, discs tended to become shorter, move further forward and distort more seriously in ADDWoR group than in ADDWR group after follow-up. Moreover, discs were prone to become shorter and more anteriorly displaced in teenagers, type I and III morphologies, advanced Wilkes stages, or those with joint effusion. Follow-up period seemed to be not critical.