Sample records for disc replacement tdr

  1. Two-level total lumbar disc replacement.

    PubMed

    Di Silvestre, Mario; Bakaloudis, Georgios; Lolli, Francesco; Vommaro, Francesco; Parisini, Patrizio

    2009-06-01

    Total lumbar disc replacement (TDR) has been widely used as a treatment option for 2-level symptomatic degenerative disc disease. However, recent studies have presented conflicting results and some authors concluded that outcome deteriorated when disc replacement was performed bisegmentally, with an increase of complications for bisegmental replacements in comparison with monosegmental disc arthroplasty. The goal of the present retrospective study is to investigate results in a group of patients who have received bisegmental TDR with SB Charitè III artificial disc for degenerative disc disease with a minimum follow-up of 3 years, and to compare the results of 2-level disc replacement versus 1-level patients treated with the same prosthesis. A total of 32 patients had at least 3-years follow-up and were reviewed. The average age of the patients was 38.5 years. There were 11 males and 21 females. About 16 patients received 2-level TDR (SB Charitè III) and 16 received 1-level TDR (SB Charitè III). Both radiographic and functional outcome analysis, including patient's satisfaction, was performed. There were no signs of degenerative changes of the adjacent segments in any case of the 2- or 1-level TDR. There was no statistically significant difference between 2- and 1-level TDR both at 12 months and at 3-years follow-up on functional outcome scores. There was a statistically insignificant difference concerning the patients satisfaction between 1- and 2-level surgeries at the last follow-up (P = 0.46). In the 2-level TDR patients, there were 5 minor complications (31.25%), whereas major complications occurred in 4 more patients (25%) and required a new surgery in 2 cases (12.5%). In the 1-level cases there were 2 minor complications (12.5%) and 2 major complications (12.5%) and a new revision surgery was required in 1 patient (6.25%). In conclusion, the use of 2-level disc replacement at last follow-up presented a higher incidence of complications than in cases with 1-level replacement. At the same time it was impossible to delineate a clear difference in evaluating the questionnaires between the follow-up results of patients receiving 2- and 1-level TDR: the 2-level group presented slightly lower scores at follow-up, but none was statistically significant.

  2. Comparative charge analysis of one- and two-level lumbar total disc arthroplasty versus circumferential lumbar fusion.

    PubMed

    Levin, David A; Bendo, John A; Quirno, Martin; Errico, Thomas; Goldstein, Jeffrey; Spivak, Jeffrey

    2007-12-01

    This is a retrospective, independent study comparing 2 groups of patients treated surgically for discogenic low back pain associated with degenerative disc disease (DDD) in the lumbosacral spine. To compare the surgical and hospitalization charges associated with 1- and 2-level lumbar total disc replacement and circumferential lumbar fusion. Reported series of lumbar total disc replacement have been favorable. However, economic aspects of lumbar total disc replacement (TDR) have not been published or studied. This information is important considering the recent widespread utilization of new technologies. Recent studies have demonstrated comparable short-term clinical results between TDR and lumbar fusion recipients. Relative charges may be another important indicator of the most appropriate procedure. We report a hospital charge-analysis comparing ProDisc lumbar disc replacement with circumferential fusion for discogenic low back pain. In a cohort of 53 prospectively selected patients with severe, disabling back pain and lumbar disc degeneration, 36 received Synthes ProDisc TDR and 17 underwent circumferential fusion for 1- and 2-level degenerative disc disease between L3 and S1. Randomization was performed using a 2-to-1 ratio of ProDisc recipients to control spinal fusion recipients. Charge comparisons, including operating room charges, inpatient hospital charges, and implant charges, were made from hospital records using inflation-corrected 2006 U.S. dollars. Operating room times, estimated blood loss, and length of stay were obtained from hospital records as well. Surgeon and anesthesiologist fees were, for the purposes of comparison, based on Medicare reimbursement rates. Statistical analysis was performed using a 2-tailed Student t test. For patients with 1-level disease, significant differences were noted between the TDR and fusion control group. The mean total charge for the TDR group was $35,592 versus $46,280 for the fusion group (P = 0.0018). Operating room charges were $12,000 and $18,950, respectively, for the TDR and fusion groups (P < 0.05). Implant charges averaged $13,990 for the fusion group, which is slightly higher than the $13,800 for the ProDisc (P = 0.9). Estimated blood loss averaged 794 mL in the fusion group versus 412 mL in the TDR group (P = 0.0058). Mean OR minutes averaged 344 minutes for the fusion group and 185 minutes for the TDR (P < 0.05) Mean length of stay was 4.78 days for fusion versus 4.32 days for TDR (P = 0.394). For patients with 2-level disease, charges were similar between the TDR and fusion groups. The mean total charge for the 2-level TDR group was $55,524 versus $56,823 for the fusion group (P = 0.55). Operating room charges were $15,340 and $20,560, respectively, for the TDR and fusion groups (P = 0.0003). Surgeon fees and anesthesiologist charges based on Medicare reimbursement rates were $5857 and $525 for the fusion group, respectively, versus $2826 and $331 for the TDR group (P < 0.05 for each). Implant charges were significantly lower for the fusion group (mean, $18,460) than those for 2-level Synthes ProDisc ($27,600) (P < 0.05). Operative time averaged 387 minutes for fusion versus 242 minutes for TDR (P < 0.0001). EBL and length of stay were similar. Patients undergoing 1- and 2-level ProDisc total disc replacement spent significantly less time in the OR and had less EBL than controls. Charges were significantly lower for TDR compared with circumferential fusions in the 1-level patient group, while charges were similar in the 2-level group.

  3. Barriers to and Budget Impact of Lumbar Total Disc Replacement Utilization.

    PubMed

    Sandhu, Faheem; Blumenthal, Scott; Grunch, Betsy; Kimball, Bent; Ferko, Nicole; Hollmann, Sarah

    2017-12-15

    : Evidence on the favorable efficacy, safety, and cost effectiveness of lumbar total disc replacement (TDR) compared with fusion for lumbar degenerative disc disease is mounting; however, a key barrier identified for TDR utilization is lack of coverage by US health insurers. Although economic considerations in a fee-for-service model should not be a determining factor in patient access, concerns regarding the budget impact of lumbar TDR surgery may unfortunately underlie coverage decisions. On the basis of the data available and economic modeling, the panel agreed that there is no indication that there would be a dramatic increase in patients seeking lumbar TDR. Considering several possible scenarios on potential growth in TDR utilization with coverage, as well as growth in the overall surgical pool of patients, economic modeling demonstrated that adoption of lumbar TDR would result in minimal or no budget impact for commercial insurance plans. Considering these model results and the economic literature, the panel concluded that adopting lumbar TDR within a coverage policy is expected to remain cost neutral for the insurer.

  4. Subsequent surgery rates after cervical total disc replacement using a Mobi-C Cervical Disc Prosthesis versus anterior cervical discectomy and fusion: a prospective randomized clinical trial with 5-year follow-up.

    PubMed

    Jackson, Robert J; Davis, Reginald J; Hoffman, Gregory A; Bae, Hyun W; Hisey, Michael S; Kim, Kee D; Gaede, Steven E; Nunley, Pierce Dalton

    2016-05-01

    OBJECTIVE Cervical total disc replacement (TDR) has been shown in a number of prospective clinical studies to be a viable treatment alternative to anterior cervical discectomy and fusion (ACDF) for the treatment of symptomatic degenerative disc disease. In addition to preserving motion, evidence suggests that cervical TDR may result in a lower incidence of subsequent surgical intervention than treatment with fusion. The goal of this study was to evaluate subsequent surgery rates up to 5 years in patients treated with TDR or ACDF at 1 or 2 contiguous levels between C-3 and C-7. METHODS This was a prospective, multicenter, randomized, unblinded clinical trial. Patients with symptomatic degenerative disc disease were enrolled to receive 1- or 2-level treatment with either TDR as the investigational device or ACDF as the control treatment. There were 260 patients in the 1-level study (179 TDR and 81 ACDF patients) and 339 patients in the 2-level study (234 TDR and 105 ACDF patients). RESULTS At 5 years, the occurrence of subsequent surgical intervention was significantly higher among ACDF patients for 1-level (TDR, 4.5% [8/179]; ACDF, 17.3% [14/81]; p = 0.0012) and 2-level (TDR, 7.3% [17/234]; ACDF, 21.0% [22/105], p = 0.0007) treatment. The TDR group demonstrated significantly fewer index- and adjacent-level subsequent surgeries in both the 1- and 2-level cohorts. CONCLUSIONS Five-year results showed treatment with cervical TDR to result in a significantly lower rate of subsequent surgical intervention than treatment with ACDF for both 1 and 2 levels of treatment. Clinical trial registration no.: NCT00389597 ( clinicaltrials.gov ).

  5. Effect of total lumbar disc replacement on lumbosacral lordosis.

    PubMed

    Kasliwal, Manish K; Deutsch, Harel

    2012-10-01

    Original article : To study effect of lumbar disc replacement on lumbosacral lordosis. There has been a growing interest in total disc replacement (TDR) for back pain with the rising concern of adjacent segment degeneration. Lumbar fusion surgery has been shown to lead to decrease in lumbar lordosis, which may account for postfusion pain resulting in less acceptable clinical outcome after successful fusion. TDR has recently emerged as an alternative treatment for back pain. There have been very few studies reporting lumbar sagittal outcome after TDR. Retrospective study of radiographic data of 17 patients who underwent TDR for single level degenerative disc disease at the author's institution was carried out. Study included measurement of preoperative and postoperative segmental and global lumbar lordosis and angle of lordosis. Patients age varied from 19 to 54 (mean, 35) years. Follow-up ranged from 12 to 24 months. TDR was performed at L4-5 level in 3 patients and L5-S1 level in 14 patients. The average values for segmental lordosis, global lordosis, and angle of lordosis at the operated level before and after surgery were 17.3, 49.7, and 8.6 degrees and 21.6, 54, and 9.5 degrees, respectively. There was a trend toward significant (P=0.02) and near significant (P=0.057) increase in segmental and global lordosis, respectively after TDR. Although prosthesis increased angle of lordosis at the level implanted in majority of the patients, the difference in preoperative and postoperative angle of lordosis was not significant (P=0.438). In addition, there was no correlation between the angle of implant of chosen and postoperative angle of lordosis at the operated level. The effect of TDR on sagittal balance appears favorable with an increase in global and segmental lumbar lordosis after single level TDR for degenerative disc disease. The degree of postoperative angle of lordosis was not affected by the angle of implant chosen at the operated level and varied independently of the implant angle.

  6. M6-C artificial disc placement.

    PubMed

    Coric, Domagoj; Parish, John; Boltes, Margaret O

    2017-01-01

    There has been a steady evolution of cervical total disc replacement (TDR) devices over the last decade resulting in surgical technique that closely mimics anterior cervical discectomy and fusion as well as disc design that emphasizes quality of motion. The M6-C TDR device is a modern-generation artificial disc composed of titanium endplates with tri-keel fixation as well as a polyethylene weave with a polyurethane core. Although not yet approved by the FDA, M6-C has finished a pilot and pivotal US Investigational Device Exemption (IDE) study. The authors present the surgical technique for implantation of a 2-level M6-C cervical TDR device. The video can be found here: https://youtu.be/rFEAqINLRCo .

  7. Cost Utility Analysis of the Cervical Artificial Disc vs Fusion for the Treatment of 2-Level Symptomatic Degenerative Disc Disease: 5-Year Follow-up.

    PubMed

    Ament, Jared D; Yang, Zhuo; Nunley, Pierce; Stone, Marcus B; Lee, Darrin; Kim, Kee D

    2016-07-01

    The cervical total disc replacement (cTDR) was developed to treat cervical degenerative disc disease while preserving motion. Cost-effectiveness of this intervention was established by looking at 2-year follow-up, and this update reevaluates our analysis over 5 years. Data were derived from a randomized trial of 330 patients. Data from the 12-Item Short Form Health Survey were transformed into utilities by using the SF-6D algorithm. Costs were calculated by extracting diagnosis-related group codes and then applying 2014 Medicare reimbursement rates. A Markov model evaluated quality-adjusted life years (QALYs) for both treatment groups. Univariate and multivariate sensitivity analyses were conducted to test the stability of the model. The model adopted both societal and health system perspectives and applied a 3% annual discount rate. The cTDR costs $1687 more than anterior cervical discectomy and fusion (ACDF) over 5 years. In contrast, cTDR had $34 377 less productivity loss compared with ACDF. There was a significant difference in the return-to-work rate (81.6% compared with 65.4% for cTDR and ACDF, respectively; P = .029). From a societal perspective, the incremental cost-effective ratio (ICER) for cTDR was -$165 103 per QALY. From a health system perspective, the ICER for cTDR was $8518 per QALY. In the sensitivity analysis, the ICER for cTDR remained below the US willingness-to-pay threshold of $50 000 per QALY in all scenarios (-$225 816 per QALY to $22 071 per QALY). This study is the first to report the comparative cost-effectiveness of cTDR vs ACDF for 2-level degenerative disc disease at 5 years. The authors conclude that, because of the negative ICER, cTDR is the dominant modality. ACDF, anterior cervical discectomy and fusionAWP, average wholesale priceCE, cost-effectivenessCEA, cost-effectiveness analysisCPT, Current Procedural TerminologycTDR, cervical total disc replacementCUA, cost-utility analysisDDD, degenerative disc diseaseDRG, diagnosis-related groupFDA, US Food and Drug AdministrationICER, incremental cost-effectiveness ratioIDE, Investigational Device ExemptionNDI, neck disability indexQALY, quality-adjusted life yearsRCT, randomized controlled trialRTW, return-to-workSF-12, 12-Item Short Form Health SurveyVAS, visual analog scaleWTP, willingness-to-pay.

  8. Material Science in Cervical Total Disc Replacement.

    PubMed

    Pham, Martin H; Mehta, Vivek A; Tuchman, Alexander; Hsieh, Patrick C

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation.

  9. Material Science in Cervical Total Disc Replacement

    PubMed Central

    Pham, Martin H.; Mehta, Vivek A.; Tuchman, Alexander; Hsieh, Patrick C.

    2015-01-01

    Current cervical total disc replacement (TDR) designs incorporate a variety of different biomaterials including polyethylene, stainless steel, titanium (Ti), and cobalt-chrome (CoCr). These materials are most important in their utilization as bearing surfaces which allow for articular motion at the disc space. Long-term biological effects of implanted materials include wear debris, host inflammatory immune reactions, and osteolysis resulting in implant failure. We review here the most common materials used in cervical TDR prosthetic devices, examine their bearing surfaces, describe the construction of the seven current cervical TDR devices that are approved for use in the United States, and discuss known adverse biological effects associated with long-term implantation of these materials. It is important to appreciate and understand the variety of biomaterials available in the design and construction of these prosthetics and the considerations which guide their implementation. PMID:26523281

  10. Prospective, Randomized Comparison of One-level Mobi-C Cervical Total Disc Replacement vs. Anterior Cervical Discectomy and Fusion: Results at 5-year Follow-up

    PubMed Central

    Zigler, Jack E.; Jackson, Robert; Nunley, Pierce D.; Bae, Hyun W.; Kim, Kee D.; Ohnmeiss, Donna D.

    2016-01-01

    Introduction There is increasing interest in the role of cervical total disc replacement (TDR) as an alternative to anterior cervical discectomy and fusion (ACDF). Multiple prospective randomized studies with minimum 2 year follow-up have shown TDR to be at least as safe and effective as ACDF in treating symptomatic degenerative disc disease at a single level. The purpose of this study was to compare outcomes of cervical TDR using the Mobi-C® with ACDF at 5-year follow-up. Methods This prospective, randomized, controlled trial was conducted as a Food and Drug Administration regulated Investigational Device Exemption trial across 23 centers with 245 patients randomized (2:1) to receive TDR with Mobi-C® Cervical Disc Prosthesis or ACDF with anterior plate and allograft. Outcome assessments included a composite overall success score, Neck Disability Index (NDI), visual analog scales (VAS) assessing neck and arm pain, Short Form-12 (SF-12) health survey, patient satisfaction, major complications, subsequent surgery, segmental range of motion, and adjacent segment degeneration. Results The 60-month follow-up rate was 85.5% for the TDR group and 78.9% for the ACDF group. The composite overall success was 61.9% with TDR vs. 52.2% with ACDF, demonstrating statistical non-inferiority. Improvements in NDI, VAS neck and arm pain, and SF-12 scores were similar between groups and were maintained from earlier follow-up through 60 months. There was no significant difference between TDR and ACDF in adverse events or major complications. Range of motion was maintained with TDR through 60 months. Device-related subsequent surgeries (TDR: 3.0%, ACDF: 11.1%, p<0.02) and adjacent segment degeneration at the superior level (TDR: 37.1%, ACDF: 54.7%, p<0.03) were significantly lower for TDR patients. Conclusions Five-year results demonstrate the safety and efficacy of TDR with the Mobi-C as a viable alternative to ACDF with the potential advantage of lower rates of reoperation and adjacent segment degeneration, in the treatment of one-level symptomatic cervical degenerative disc disease. Clinical Relevance This prospective, randomized study with 5-year follow-up adds to the existing literature indicating that cervical TDR is a viable alternative to ACDF in appropriately selected patients. Level of Evidence This is a Level I study. PMID:27162712

  11. Cost-effectiveness of total disc replacement versus multidisciplinary rehabilitation in patients with chronic low back pain: a Norwegian multicenter RCT.

    PubMed

    Johnsen, Lars Gunnar; Hellum, Christian; Storheim, Kjersti; Nygaard, Øystein P; Brox, Jens Ivar; Rossvoll, Ivar; Rø, Magne; Andresen, Hege; Lydersen, Stian; Grundnes, Oliver; Pedersen, Marit; Leivseth, Gunnar; Olafsson, Gylfi; Borgström, Fredrik; Fritzell, Peter

    2014-01-01

    Randomized clinical trial with 2-year follow-up. To evaluate the cost-effectiveness of total disc replacement (TDR) versus multidisciplinary rehabilitation (MDR) in patients with chronic low back pain (CLBP). The existing studies on CLBP report cost-effectiveness of fusion surgery versus disc replacement and fusion versus rehabilitation. This study evaluated the cost-effectiveness of TDR versus MDR. Between April 2004 and May 2007, 173 patients with CLBP (>1 yr) were randomized to TDR (n = 86) or MDR (n = 87). Treatment effects (Euro Qol 5D [EQ-5D] and Short Form 6D [SF-6D]) and relevant direct and indirect costs at 6 weeks and at 3, 6, 12, and 24 months after treatment were assessed. Gain in quality-adjusted life years (QALYs) after 2 years was estimated. Cost-effectiveness was expressed as an incremental cost-effectiveness ratio. The mean QALYs gained (standard deviation) using EQ-5D was 1.29 (0.53) in the TDR group and 0.95 (0.52) in the MDR group, a significant difference of 0.34 (95% confidence interval 0.18-0.50). The mean total cost per patient in the TDR group was &OV0556;87,622 (58,351) compared with &OV0556;74,116 (58,237) in the MDR group, which was not significantly different (95% confidence interval: -4041 to 31,755). The incremental cost-effectiveness ratio for the TDR procedure varied from &OV0556;39,748 using EQ-5D (TDR cost-effective) to &OV0556;128,328 using SF-6D (TDR not cost-effective). The dropout rate was 20% (15% TDR group, 24% MDR group). Five patients moved from the MDR to the TDR group, whereas 9 patients randomized to TDR declined surgery. Using per-protocol analysis instead of intention-to-treat analysis indicated that TDR was not cost-effective, irrespective of the use of EQ-5D or SF-6D. In this study, TDR was cost-effective compared with MDR after 2 years when using EQ-5D for assessing QALYs gained and a willingness to pay of &OV0556;74,600 (kr500,000/QALY). TDR was not cost-effective when SF-6D was used; therefore, our results should be interpreted with caution. Longer follow-up is needed to accurately assess the cost-effectiveness of TDR. 2.

  12. Symptomatic adjacent segment disease after cervical total disc replacement: re-examining the clinical and radiological evidence with established criteria.

    PubMed

    Nunley, Pierce D; Jawahar, Ajay; Cavanaugh, David A; Gordon, Charles R; Kerr, Eubulus J; Utter, Phillip Andrew

    2013-01-01

    Although several publications in the last decade have proved equality in safety and efficacy of the total disc replacement (TDR) to the anterior fusion procedure in cervical spine, the claim that TDR may reduce the incidence of adjacent segment disease (ASD) has not been corroborated by clinical evidence. We attempt to predict the true incidence of symptomatic ASD after TDR surgery in the cervical spine at one or two levels at a median follow-up period of 4 years. A total of 763 patients were screened to participate in four different Food and Drug Administration device exemption trials for artificial cervical disc replacement at three collaborating institutions. Two hundred seventy-one patients qualified and enrolled in the trials. One hundred seventy-three randomized to receive artificial disc replacement surgery, and 167 have completed a 4-year or longer follow-up. Patients experiencing cervical radiculopathy symptoms in the follow-up period were worked-up with clinical examinations, magnetic resonance imaging of the cervical spine, and other diagnostic studies. Once a clinical correlation was established with the imaging evidence of adjacent segment degeneration, a careful record was maintained to document the subsequent medical and/or surgical treatment received by these patients. Statistical analysis was performed to determine the true incidence of and factors affecting the ASD after cervical disc replacement in these patients. Twenty-six patients (15.2%) were identified to satisfy our criteria for ASD at the median follow-up of 51 months, with the annual incidence of 3.1% as calculated by life tables. The actuarial 5-year freedom from ASD rate was 71.6%±0.6%, and the mean period for freedom from ASD was 70.4±2.1 months. The incidence of symptomatic ASD after cervical TDR is 3.1% annually regardless of the patient's age, sex, smoking habits, and design of the TDR device. The presence of osteopenia and lumbar degenerative disease significantly increase the risk of developing ASD after anterior cervical surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Biomechanical Analysis of Cervical Disc Replacement and Fusion Using Single Level, Two Level, and Hybrid Constructs.

    PubMed

    Gandhi, Anup A; Kode, Swathi; DeVries, Nicole A; Grosland, Nicole M; Smucker, Joseph D; Fredericks, Douglas C

    2015-10-15

    A biomechanical study comparing arthroplasty with fusion using human cadaveric C2-T1 spines. To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs. Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration. 11 specimens (C2-T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5-C6, 2-level TDR at C5-C6-C7, fusion at C5-C6 and TDR at C6-C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2-T1) matched the motion of the respective intact state (hybrid control). An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels. Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion.

  14. Return to Sports After Cervical Total Disc Replacement.

    PubMed

    Reinke, Andreas; Behr, Michael; Preuss, Alexander; Villard, Jimmy; Meyer, Bernhard; Ringel, Florian

    2017-01-01

    Total disc replacement (TDR) is typically indicated in young patients with a cervical soft disc herniation. There are few data on the activity level of patients after cervical TDR, in particular from young patients who are expected to have a high activity level with frequent exercising. The expectation is that returning to active sports after cervical TDR is not restricted. Fifty patients were treated with a monosegmental cervical TDR at our department between May 2006 and March 2012. Clinical status and radiographic parameters were evaluated preoperatively and during follow-up. In addition, information was gathered regarding neck disability index, pain, a questionnaire concerning athletic aspects, and a modified Tegner activity score. The study design was a prospective case series. All patients were treated with the Prestige artificial cervical disc for a single-level soft disc herniation with radiculopathy. The average age was 40 years, and the mean follow-up period was 53 months (range, 26-96). The median neck disability index during follow-up was 5, and median visual analog scale for pain was 2. Two professional athletes, 20 semiprofessionals, 24 hobby athletes, and 5 patients with a very low activity level were treated. The median time to resumption of sporting activity was 4 weeks after surgery. All professionals and semiprofessionals recovered to their previous activity level. All of the 20 hobby athletes recovered to resume their sport participation. The modified Tegner preoperative score was 4 and the postoperative score was 3.5 (P = 0.806). We found that cervical TDR did not prohibit sporting activities. All patients recovered and were able to take part in their previous activities at an appropriate intensity level. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    PubMed Central

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration − the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval − the activL® Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. PMID:27274317

  16. ISASS Policy Statement – Lumbar Artificial Disc

    PubMed Central

    Garcia, Rolando

    2015-01-01

    Purpose The primary goal of this Policy Statement is to educate patients, physicians, medical providers, reviewers, adjustors, case managers, insurers, and all others involved or affected by insurance coverage decisions regarding lumbar disc replacement surgery. Procedures This Policy Statement was developed by a panel of physicians selected by the Board of Directors of ISASS for their expertise and experience with lumbar TDR. The panel's recommendation was entirely based on the best evidence-based scientific research available regarding the safety and effectiveness of lumbar TDR. PMID:25785243

  17. Complications of Lumbar Artificial Disc Replacement Compared to Fusion: Results From the Prospective, Randomized, Multicenter US Food and Drug Administration Investigational Device Exemption Study of the Charité Artificial Disc

    PubMed Central

    Majd, Mohammed E.; Isaza, Jorge E.; Blumenthal, Scott L.; McAfee, Paul C.; Guyer, Richard D.; Hochschuler, Stephen H.; Geisler, Fred H.; Garcia, Rolando; Regan, John J.

    2007-01-01

    Background Previous reports of lumbar total disc replacement (TDR) have described significant complications. The US Food and Drug Administration (FDA) investigational device exemption (IDE) study of the Charité artificial disc represents the first level I data comparison of TDR to fusion. Methods In the prospective, randomized, multicenter IDE study, patients were randomized in a 2:1 ratio, with 205 patients in the Charité group and 99 patients in the control group (anterior lumbar interbody fusion [ALIF] with BAK cages). Inclusion criteria included confirmed single-level degenerative disc disease at L4-5 or L5-S1 and failure of nonoperative treatment for at least 6 months. Complications were reported throughout the study. Results The rate of approach-related complications was 9.8% in the investigational group and 10.1% in the control group. The rate of major neurological complications was similar between the 2 groups (investigational = 4.4%, control = 4.0%). There was a higher rate of superficial wound infection in the investigational group but no deep wound infections in either group. Pseudarthrosis occurred in 9.1% of control group patients. The rate of subsidence in the investigational group was 3.4%. The reoperation rate was 5.4% in the investigational group and 9.1% in the control group. Conclusions The incidence of perioperative and postoperative complications for lumbar TDR was similar to that of ALIF. Vigilance is necessary with respect to patient indications, training, and correct surgical technique to maintain TDR complications at the levels experienced in the IDE study. PMID:25802575

  18. Preferential superior surface motion in wear simulations of the Charité total disc replacement.

    PubMed

    Goreham-Voss, Curtis M; Vicars, Rachel; Hall, Richard M; Brown, Thomas D

    2012-06-01

    Laboratory wear simulations of the dual-bearing surface Charité total disc replacement (TDR) are complicated by the non-specificity of the device's center of rotation (CoR). Previous studies have suggested that articulation of the Charité preferentially occurs at the superior-bearing surface, although it is not clear how sensitive this phenomenon is to lubrication conditions or CoR location. In this study, a computational wear model is used to study the articulation kinematics and wear of the Charité TDR. Implant wear was found to be insensitive to the CoR location, although seemingly non-physiologic endplate motion can result. Articulation and wear were biased significantly to the superior-bearing surface, even in the presence of significant perturbations of loading and friction. The computational wear model provides novel insight into the mechanics and wear of the Charité TDR, allowing for better interpretation of in vivo results, and giving useful insight for designing future laboratory physical tests.

  19. Dynamic biomechanical examination of the lumbar spine with implanted total disc replacement using a pendulum testing system.

    PubMed

    Daniels, Alan H; Paller, David J; Koruprolu, Sarath; McDonnell, Matthew; Palumbo, Mark A; Crisco, Joseph J

    2012-11-01

    Biomechanical cadaver investigation. To examine dynamic bending stiffness and energy absorption of the lumbar spine with and without implanted total disc replacement (TDR) under simulated physiological motion. The pendulum testing system is capable of applying physiological compressive loads without constraining motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. Five unembalmed, frozen human lumbar FSUs were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Synthes ProDisc-L TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5º resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N·m/º) was calculated and compared for each testing mode. In flexion/extension, the TDR constructs reached equilibrium with significantly (P < 0.05) fewer cycles than the intact FSU with compressive loads of 282 N, 385 N, and 488 N. Mean dynamic bending stiffness in flexion, extension, and lateral bending increased significantly with increasing load for both the intact FSU and TDR constructs (P < 0.001). In flexion, with increasing compressive loading from 181 N to 488 N, the bending stiffness of the intact FSUs increased from 4.0 N·m/º to 5.5 N·m/º, compared with 2.1 N·m/º to 3.6 N·m/º after TDR implantation. At each compressive load, the intact FSU was significantly stiffer than the TDR (P < 0.05). Lumbar FSUs with implanted TDR were found to be less stiff, but absorbed more energy during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion-preserving devices are not fully known, these results provide further insight into the biomechanical behavior of these devices under approximated physiological loading conditions.

  20. Dynamic Biomechanical Examination of the Lumbar Spine with Implanted Total Disc Replacement (TDR) Utilizing a Pendulum Testing System

    PubMed Central

    Daniels, Alan H; Paller, David J; Koruprolu, Sarath; McDonnell, Matthew; Palumbo, Mark A; Crisco, Joseph J

    2013-01-01

    Study Design Biomechanical cadaver investigation Objective To examine dynamic bending stiffness and energy absorption of the lumbar spine with and without implanted Total Disc Replacement (TDR) under simulated physiologic motion. Summary of background data The pendulum testing system is capable of applying physiologic compressive loads without constraining motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. Methods Five unembalmed, frozen human lumbar FSUs were tested on the pendulum system with axial compressive loads of 181N, 282N, 385N, and 488N before and after Synthes ProDisc-L TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5° resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. Results In flexion/extension, the TDR constructs reached equilibrium with significantly (p<0.05) fewer cycles than the intact FSU with compressive loads of 282N, 385N and 488N. Mean dynamic bending stiffness in flexion, extension, and lateral bending increased significantly with increasing load for both the intact FSU and TDR constructs (p<0.001). In flexion, with increasing compressive loading from 181N to 488N, the bending stiffness of the intact FSUs increased from 4.0N-m/° to 5.5N-m/°, compared to 2.1N-m/° to 3.6N-m/° after TDR implantation. At each compressive load, the intact FSU was significantly more stiff than the TDR (p<0.05). Conclusion Lumbar FSUs with implanted TDR were found to be less stiff, but also absorbed more energy during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices are not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions. PMID:22869057

  1. Long-term Evaluation of Cervical Disc Arthroplasty with the Mobi-C© Cervical Disc: A Randomized, Prospective, Multicenter Clinical Trial with Seven-Year Follow-up.

    PubMed

    Radcliff, Kris; Davis, Reginald J; Hisey, Michael S; Nunley, Pierce D; Hoffman, Gregory A; Jackson, Robert J; Bae, Hyun W; Albert, Todd; Coric, Dom

    2017-01-01

    Cervical total disc replacement (TDR) is an increasingly accepted procedure for the treatment of symptomatic cervical degenerative disc disease. Multiple Level I evidence clinical trials have established cervical TDR to be a safe and effective procedure in the short-term. The objective of this study is to provide a long-term assessment of TDR versus anterior discectomy and fusion for the treatment of one- and two-level disc disease. This study was a continuation of a prospective, multicenter, randomized, US FDA IDE clinical trial comparing cervical TDR with the Mobi-C © Cervical Disc versus ACDF through 7 years follow-up. Inclusion criteria included a diagnosis of symptomatic cervical degenerative disc disease at one or two cervical levels. TDR patients were treated using a Mobi-C © artificial disc (Zimmer Biomet, Austin TX, USA). ACDF with allograft and anterior plate was used as a control treatment. Outcome measures were collected preoperatively and postoperatively at 6 weeks, at 3, 6, 12, 18 months, annually through 60 months, and at 84 months. Measured outcomes included Overall success, Neck Disability Index (NDI), VAS neck and arm pain, segmental range of motion (ROM), patient satisfaction, SF-12 MCS/PCS, major complications, and subsequent surgery rate. The primary endpoint was an FDA composite definition of success comprising clinical improvement and an absence of major complications and secondary surgery events. A total of 599 patients were enrolled and treated, with 164 treated with one-level TDR, 225 treated with two-level TDR, 81 treated with one-level ACDF, and 105 treated with two-level ACDF. At seven years, follow-up rates ranged from 73.5% to 84.4% (overall 80.2%).The overall success rates of two level TDR and ACDF patients were 60.8% and 34.2%, respectively (p<0.0001). The overall success rates of one level TDR and ACDF patients were 55.2% and 50%, respectively (p>0.05). Both the single and two level TDR and ACDF groups showed significant improvement from baseline NDI scores, VAS neck and arm pain scores, and SF-12 MCS/PCS scores (p<0.0001). In the single level cohort, there was an increased percentage of TDR patients who reported themselves as "very satisfied" (TDR 90.9% vs ACDF 77.8%; p= 0.028). There was a lower rate of adjacent level secondary surgery in the single level TDR patients (3.7%) versus the ACDF patients (13.6%; p = 0.007).In the two level TDR group, the NDI success rate was significantly greater in the TDR group (TDR: 79.0% vs. ACDF: 58.0%; p=0.001). There was significantly more improvement in NDI change score at 7 years in the TDR patients versus ACDF. The TDR group had a significantly higher rate of patients who were "very satisfied" with their treatment compared to the ACDF group (TDR: 85.9% vs. ACDF: 73.9%). The rate of subsequent surgery at the index level was significantly lower in the TDR group compared to the ACDF group (TDR: 4.4% vs. ACDF: 16.2%; p=0.001). The rate of adjacent level secondary surgery was significantly lower in the two level TDR (4.4%) patients compared to the ACDF (11.3%; p=0.03) patients. In both single and two level cohorts, the percentage of patients with worse NDI (2.5%-3.8% of two level surgeries and 1.2%-2.5% of single level surgeries) or worse neck pain (5%-6.8% of the two level surgeries and 1.3% - 3.8% of the single level surgeries) was strikingly low in both groups but trended lower in the TDR patients. At seven years, the composite success analysis demonstrated clinical superiority of two level TDR over ACDF and non-inferiority of single level TDR versus ACDF. There were lower rates of secondary surgery and higher adjacent level disc survivorship in both groups. Both surgeries were remarkably effective in alleviating pain relative to baseline and the rate of patients with worse disability or neck pain was surprisingly low. Overall, greater than 95% of patients (from both groups) who underwent TDR and 88% of patients who underwent ACDF were "very satisfied" at seven years. The differences in clinical effectiveness of TDR versus ACDF becomes more apparent as treatment increases from one to two levels, indicating a significant benefit for TDR over ACDF for two-level procedures. The Mobi-C Clinical Trial (ClinicalTrials.gov registration number: NCT00389597) was conducted at 24 sites in the US and was approved by the Institutional Review Board, Research Ethics Committee, or local equivalent of each participating site. 1.

  2. Outpatient and Inpatient Single-Level Cervical Total Disc Replacement: A Comparison of 30-day Outcomes.

    PubMed

    Segal, Dale N; Wilson, Jacob M; Staley, Christopher; Yoon, Tim S

    2018-06-11

    Retrospective cohort study. To compare 30-day postoperative outcomes between patients undergoing outpatient and inpatient single-level cervical total disc replacement surgery. Cervical total disc replacement (TDR) is a motion sparing treatment for cervical radiculopathy and myelopathy. It is an alternative to anterior cervical discectomy and fusion (ACDF) with a similar complication rate. Like ACDF, it may be performed in the inpatient or outpatient setting. Efforts to reduce healthcare costs are driving spine surgery to be performed in the outpatient setting. As cervical total disc replacement surgery continues to gain popularity, the safety of treating patients on an outpatient basis needs to be validated. The National Surgical Quality Improvement Program (NSQIP) database was queried for patients who underwent single-level cervical disc replacement surgery between 2006-2015. Complication data including 30-day complications, reoperation rate, readmission rate, and length of stay data was compared between the inpatient and outpatient cohort using univariate analysis. There were 531 (34.2%) patients treated as outpatients and 1,022 (65.8%) were treated on an inpatient basis. The two groups had similar baseline characteristics. The overall 30-day complication rate was 1.4% for inpatients and 0.6% for outpatients. Reoperation rate was 0.6% for inpatient and 0.4% for outpatients. Readmission rate was 0.9% and 0.8% for inpatient and outpatient, respectively. There were no statistical differences identified in rates of readmission, reoperation, or complication between the inpatient and outpatient cohorts. There was no difference between 30-day complications, readmission and reoperation rates between inpatients and outpatients who underwent a single-level cervical total disc replacement. Furthermore, the overall 30-day complication rates were low. This study supports that single-level cervical TDR can be performed safely in an outpatient setting. 3.

  3. Disc replacement adjacent to cervical fusion: a biomechanical comparison of hybrid construct versus two-level fusion.

    PubMed

    Lee, Michael J; Dumonski, Mark; Phillips, Frank M; Voronov, Leonard I; Renner, Susan M; Carandang, Gerard; Havey, Robert M; Patwardhan, Avinash G

    2011-11-01

    A cadaveric biomechanical study. To investigate the biomechanical behavior of the cervical spine after cervical total disc replacement (TDR) adjacent to a fusion as compared to a two-level fusion. There are concerns regarding the biomechanical effects of cervical fusion on the mobile motion segments. Although previous biomechanical studies have demonstrated that cervical disc replacement normalizes adjacent segment motion, there is a little information regarding the function of a cervical disc replacement adjacent to an anterior cervical decompression and fusion, a potentially common clinical application. Nine cadaveric cervical spines (C3-T1, age: 60.2 ± 3.5 years) were tested under load- and displacement-control testing. After intact testing, a simulated fusion was performed at C4-C5, followed by C6-C7. The simulated fusion was then reversed, and the response of TDR at C5-C6 was measured. A hybrid construct was then tested with the TDR either below or above a single-level fusion and contrasted with a simulated two-level fusion (C4-C6 and C5-C7). The external fixator device used to simulate fusion significantly reduced range of motion (ROM) at C4-C5 and C6-C7 by 74.7 ± 8.1% and 78.1 ± 11.5%, respectively (P < 0.05). Removal of the fusion construct restored the motion response of the spinal segments to their intact state. Arthroplasty performed at C5-C6 using the porous-coated motion disc prosthesis maintained the total flexion-extension ROM to the level of the intact controls when used as a stand-alone procedure or when implanted adjacent to a single-level fusion (P > 0.05). The location of the single-level fusion, whether above or below the arthroplasty, did not significantly affect the motion response of the arthroplasty in the hybrid construct. Performing a two-level fusion significantly increased the motion demands on the nonoperated segments as compared to a hybrid TDR-plus fusion construct when the spine was required to reach the same motion end points. The spine with a hybrid construct required significantly less extension moment than the spine with a two-level fusion to reach the same extension end point. The porous-coated motion cervical prosthesis restored the ROM of the treated level to the intact state. When the porous-coated motion prosthesis was used in a hybrid construct, the TDR response was not adversely affected. A hybrid construct seems to offer significant biomechanical advantages over two-level fusion in terms of reducing compensatory adjacent-level hypermobility and also loads required to achieve a predetermined ROM.

  4. Long-term Evaluation of Cervical Disc Arthroplasty with the Mobi-C© Cervical Disc: A Randomized, Prospective, Multicenter Clinical Trial with Seven-Year Follow-up

    PubMed Central

    Davis, Reginald J.; Hisey, Michael S.; Nunley, Pierce D.; Hoffman, Gregory A.; Jackson, Robert J.; Bae, Hyun W.; Albert, Todd; Coric, Dom

    2017-01-01

    Background Cervical total disc replacement (TDR) is an increasingly accepted procedure for the treatment of symptomatic cervical degenerative disc disease. Multiple Level I evidence clinical trials have established cervical TDR to be a safe and effective procedure in the short-term. The objective of this study is to provide a long-term assessment of TDR versus anterior discectomy and fusion for the treatment of one- and two-level disc disease. Methods This study was a continuation of a prospective, multicenter, randomized, US FDA IDE clinical trial comparing cervical TDR with the Mobi-C© Cervical Disc versus ACDF through 7 years follow-up. Inclusion criteria included a diagnosis of symptomatic cervical degenerative disc disease at one or two cervical levels. TDR patients were treated using a Mobi-C© artificial disc (Zimmer Biomet, Austin TX, USA). ACDF with allograft and anterior plate was used as a control treatment. Outcome measures were collected preoperatively and postoperatively at 6 weeks, at 3, 6, 12, 18 months, annually through 60 months, and at 84 months. Measured outcomes included Overall success, Neck Disability Index (NDI), VAS neck and arm pain, segmental range of motion (ROM), patient satisfaction, SF-12 MCS/PCS, major complications, and subsequent surgery rate. The primary endpoint was an FDA composite definition of success comprising clinical improvement and an absence of major complications and secondary surgery events. Results A total of 599 patients were enrolled and treated, with 164 treated with one-level TDR, 225 treated with two-level TDR, 81 treated with one-level ACDF, and 105 treated with two-level ACDF. At seven years, follow-up rates ranged from 73.5% to 84.4% (overall 80.2%). The overall success rates of two level TDR and ACDF patients were 60.8% and 34.2%, respectively (p<0.0001). The overall success rates of one level TDR and ACDF patients were 55.2% and 50%, respectively (p>0.05). Both the single and two level TDR and ACDF groups showed significant improvement from baseline NDI scores, VAS neck and arm pain scores, and SF-12 MCS/PCS scores (p<0.0001). In the single level cohort, there was an increased percentage of TDR patients who reported themselves as “very satisfied” (TDR 90.9% vs ACDF 77.8%; p= 0.028). There was a lower rate of adjacent level secondary surgery in the single level TDR patients (3.7%) versus the ACDF patients (13.6%; p = 0.007). In the two level TDR group, the NDI success rate was significantly greater in the TDR group (TDR: 79.0% vs. ACDF: 58.0%; p=0.001). There was significantly more improvement in NDI change score at 7 years in the TDR patients versus ACDF. The TDR group had a significantly higher rate of patients who were “very satisfied” with their treatment compared to the ACDF group (TDR: 85.9% vs. ACDF: 73.9%). The rate of subsequent surgery at the index level was significantly lower in the TDR group compared to the ACDF group (TDR: 4.4% vs. ACDF: 16.2%; p=0.001). The rate of adjacent level secondary surgery was significantly lower in the two level TDR (4.4%) patients compared to the ACDF (11.3%; p=0.03) patients. In both single and two level cohorts, the percentage of patients with worse NDI (2.5%-3.8% of two level surgeries and 1.2%-2.5% of single level surgeries) or worse neck pain (5%-6.8% of the two level surgeries and 1.3% - 3.8% of the single level surgeries) was strikingly low in both groups but trended lower in the TDR patients. Conclusions At seven years, the composite success analysis demonstrated clinical superiority of two level TDR over ACDF and non-inferiority of single level TDR versus ACDF. There were lower rates of secondary surgery and higher adjacent level disc survivorship in both groups. Both surgeries were remarkably effective in alleviating pain relative to baseline and the rate of patients with worse disability or neck pain was surprisingly low. Overall, greater than 95% of patients (from both groups) who underwent TDR and 88% of patients who underwent ACDF were “very satisfied” at seven years. The differences in clinical effectiveness of TDR versus ACDF becomes more apparent as treatment increases from one to two levels, indicating a significant benefit for TDR over ACDF for two-level procedures. Ethical Standards The Mobi-C Clinical Trial (ClinicalTrials.gov registration number: NCT00389597) was conducted at 24 sites in the US and was approved by the Institutional Review Board, Research Ethics Committee, or local equivalent of each participating site. Level of Evidence 1. PMID:29372135

  5. Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

    PubMed Central

    Punt, Ilona M.; Austen, Shennah; Cleutjens, Jack P.M.; Kurtz, Steven M.; ten Broeke, René H.M.; van Rhijn, Lodewijk W.; Willems, Paul C.; van Ooij, André

    2011-01-01

    Study design Comparative study. Objective To compare periprosthetic tissue reactions observed after total disc replacement (TDR), total hip arthroplasty (THA) and total knee arthroplasty (TKA) revision surgery. Summary of background data Prosthetic wear debris leading to particle disease, followed by osteolysis, is often observed after THA and TKA. Although the presence of polyethylene (PE) particles and periprosthetic inflammation after TDR has been proven recently, osteolysis is rarely observed. The clinical relevance of PE wear debris in the spine remains poorly understood. Methods Number, size and shape of PE particles, as well as quantity and type of inflammatory cells in periprosthetic tissue retrieved during Charité TDR (n=22), THA (n=10) and TKA (n=4) revision surgery were compared. Tissue samples were stained with hematoxylin/eosin and examined by using light microscopy with bright field and polarized light. Results After THA, large numbers of PE particles <6 µm were observed, which were mainly phagocytosed by macrophages. The TKA group had a broad size range with many larger PE particles and more giant cells. In TDR, the size range was similar to that observed in TKA. However, the smallest particles were the most prevalent with 75% of the particles being <6 µm, as seen in revision THA. In TDR, both macrophages and giant cells were present with a higher number of macrophages. Conclusions Both small and large PE particles are present after TDR revision surgery compatible with both THA and TKA wear patterns. The similarities between periprosthetic tissue reactions in the different groups may give more insight in the clinical relevance of PE particles and inflammatory cells in the lumbar spine. The current findings may help to improve TDR design as applied from technologies previously developed in THA and TKA with the goal of a longer survival of TDR. PMID:21336235

  6. Cervical hybrid arthroplasty with 2 unique fusion techniques.

    PubMed

    Cardoso, Mario J; Mendelsohn, Audra; Rosner, Michael K

    2011-07-01

    Multilevel cervical arthroplasty achieved using the Prestige ST disc can be challenging and often unworkable. An alternative to this system is a hybrid technique composed of alternating total disc replacements (TDRs) and fusions. In the present study, the authors review the safety and radiological outcomes of cervical hybrid arthroplasty in which the Prestige ST disc is used in conjunction with 2 unique fusion techniques. After obtaining institutional review board approval, the authors completed a retrospective review of all hybrid cervical constructs in which the Prestige ST disc was used between August 2007 and November 2009 at the Walter Reed Army Medical Center. A Prestige ST total disc replacement was performed in 119 patients. Thirty-one patients received a hybrid construct defined as a TDR and fusion (TDR-anterior cervical decompression and fusion [ACDF]) or as 2 TDRs separated by a fusion (TDR-ACDF-TDR). A resorbable plate and graft system (Mystique) or stand-alone interbody spacer (Prevail) was implanted at the fusion levels. Plain radiographs were compared and evaluated for cervical lordosis, range of motion, implant complications, development of adjacent-level disease, and pseudarthrosis. In addition, charts were reviewed for clinical complications related to the index surgery. Thirty-one patients (18 men and 13 women; mean age 50 years, range 32-74 years) received a hybrid construct. All patients were diagnosed with radiculopathy and/or myelopathy. Twenty-four patients received a 2-level and 7 a 3-level hybrid construct. In 2 patients in whom a 2-level hybrid construct was implanted, a noncontiguous TDR was also performed. The mean clinical and radiological follow-up duration was 18 months. There was no significant difference in preoperative (19.3° ± 13.3°) and postoperative (19.7° ± 10.5°) cervical lordosis (p = 0.48), but there was a significant decrease in range in motion (from 50.0° ± 11.8° to 38.9° ± 12.7°) (p = 0.003). There were no instances of screw backout, implant dislodgement, progressive kyphosis, formation of heterotopic bone, pseudarthrosis, or symptomatic adjacent-level disease. Seven patients had dysphasia and 1 patient had vocal cord paralysis at 6 weeks. By 3 months, both the dysphasia and the vocal cord paralysis were resolved in all patients. Hybrid cervical arthroplasty involving the placement of a Prestige ST disc and either the Mystique resorbable plate or Prevail stand-alone interbody device is a safe and effective alternative to multilevel fusion for the management of cervical radiculopathy and myelopathy.

  7. Cervical total disc replacement exhibits similar stiffness to intact cervical functional spinal units tested on a dynamic pendulum testing system.

    PubMed

    Esmende, Sean M; Daniels, Alan H; Paller, David J; Koruprolu, Sarath; Palumbo, Mark A; Crisco, Joseph J

    2015-01-01

    The pendulum testing system is capable of applying physiologic compressive loads without constraining the motion of functional spinal units (FSUs). The number of cycles to equilibrium observed under pendulum testing is a measure of the energy absorbed by the FSU. To examine the dynamic bending stiffness and energy absorption of the cervical spine, with and without implanted cervical total disc replacement (TDR) under simulated physiologic motion. A biomechanical cadaver investigation. Nine unembalmed, frozen human cervical FSUs from levels C3-C4 and C5-C6 were tested on the pendulum system with axial compressive loads of 25, 50, and 100 N before and after TDR implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°, resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and the bending stiffness (Newton-meter/°) was calculated and compared for each testing mode. In flexion/extension, with increasing compressive loading from 25 to 100 N, the average number of cycles to equilibrium for the intact FSUs increased from 6.6 to 19.1, compared with 4.1 to 12.7 after TDR implantation (p<.05 for loads of 50 and 100 N). In flexion, with increasing compressive loading from 25 to 100 N, the bending stiffness of the intact FSUs increased from 0.27 to 0.59 Nm/°, compared with 0.21 to 0.57 Nm/° after TDR implantation. No significant differences were found in stiffness between the intact FSU and the TDR in flexion/extension and lateral bending at any load (p<.05). Cervical FSUs with implanted TDR were found to have similar stiffness, but had greater energy absorption than intact FSUs during cyclic loading with an unconstrained pendulum system. These results provide further insight into the biomechanical behavior of cervical TDR under approximated physiologic loading conditions. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Wear in ceramic on ceramic type lumbar total disc replacement: effect of radial clearance.

    PubMed

    Shankar, S; Kesavan, D

    2015-01-01

    The wear of the bearing surfaces of total disc replacement (TDR) is a key problem leads to reduction in the lifetime of the prosthesis and it mainly occurs due to the range of clearances of the articulating surface between the superior plate and core. The objective of this paper is to estimate the wear using finite element concepts considering the different radial clearances between the articulating surfaces of ceramic on ceramic type Lumbar Total Disc Replacement (LTDR). The finite element (FE) model was subjected to wear testing protocols according to loading profile of International Standards Organization (ISO) 18192 standards through 10 million cycles. The radial clearance value of 0.05 mm showed less volumetric wear when compared with other radial clearance values. Hence, low radial clearance values are suitable for LTDR to minimize the wear.

  9. Cervical artificial disc extrusion after a paragliding accident

    PubMed Central

    Niu, Tianyi; Hoffman, Haydn; Lu, Daniel C.

    2017-01-01

    Background: Cervical total disc replacement (TDR) is an established alternative to anterior cervical discectomy and fusion (ACDF) with excellent long-term outcomes and low failure rates. Cases of implant failure and migration are scarce and primarily limited to several years postoperatively. The authors report a case of anterior extrusion of a C4-C5 ProDisc-C (DePuy Synthes, West Chester, PA, USA) cervical artificial disc (CAD) 14 months after placement due to minor trauma. Case Description: A 33-year-old female who had undergone C4-C5 CAD implantation presented with neck pain and spasm after experiencing a paragliding accident. A 4 mm anterior protrusion of the CAD was seen on x-ray. She underwent removal of the CAD followed by anterior fusion. Other cases of CAD extrusion in the literature are discussed and the device's durability and testing are considered. Conclusion: Overall, CAD extrusion is a rare event. This case is likely the result of insufficient osseous integration. Patients undergoing cervical TDR should avoid high-risk activities to prevent trauma that could compromise the disc's placement, and future design/research should focus on how to enhance osseous integration at the interface while minimizing excessive heterotopic ossification. PMID:28781915

  10. Cervical artificial disc extrusion after a paragliding accident.

    PubMed

    Niu, Tianyi; Hoffman, Haydn; Lu, Daniel C

    2017-01-01

    Cervical total disc replacement (TDR) is an established alternative to anterior cervical discectomy and fusion (ACDF) with excellent long-term outcomes and low failure rates. Cases of implant failure and migration are scarce and primarily limited to several years postoperatively. The authors report a case of anterior extrusion of a C4-C5 ProDisc-C (DePuy Synthes, West Chester, PA, USA) cervical artificial disc (CAD) 14 months after placement due to minor trauma. A 33-year-old female who had undergone C4-C5 CAD implantation presented with neck pain and spasm after experiencing a paragliding accident. A 4 mm anterior protrusion of the CAD was seen on x-ray. She underwent removal of the CAD followed by anterior fusion. Other cases of CAD extrusion in the literature are discussed and the device's durability and testing are considered. Overall, CAD extrusion is a rare event. This case is likely the result of insufficient osseous integration. Patients undergoing cervical TDR should avoid high-risk activities to prevent trauma that could compromise the disc's placement, and future design/research should focus on how to enhance osseous integration at the interface while minimizing excessive heterotopic ossification.

  11. Comparison of sagittal parameters for anterior cervical discectomy and fusion, hybrid surgery, and total disc replacement for three levels of cervical spondylosis.

    PubMed

    Hung, Che-Wei; Wu, Ming-Fang; Yu, Gwo-Fane; Ko, Chin-Chu; Kao, Cheng-Hsing

    2018-05-01

    To analyze sagittal balance of the cervical spine after three operative methods for three consecutive levels. A retrospective case selection and observational study was performed from December 2012 to December 2015: 20 patients underwent anterior cervical discectomy and fusion, 22 patients underwent hybrid surgery (HS), and 20 patients underwent total disc replacement (TDR). Perioperative parameters, clinical outcomes, and preoperative and postoperative sagittal parameters were recorded. Clinical outcomes improved. Fusion and hybrid groups were associated with more postoperative focal lordosis than the TDR group (no significant difference). The postoperative C2-7 sagittal vertical axis (SVA) was greater in the TDR group (no significant difference). In the fusion group, the postoperative C2-7 SVA was highly correlated with the preoperative C2-7 SVA and postoperative C7 slope (C7SL). Postoperative C2-7 lordosis (C2-7L) was highly correlated with the preoperative C2-7 SVA and preoperative and postoperative C7SL. In the hybrid group, postoperative C2-7L was highly correlated with preoperative C2-7L, preoperative and postoperative focal lordosis, and C7SL. In the TDR group, the postoperative C2-7 SVA was highly correlated with the preoperative C2-7 SVA and postoperative C7 slope. The postoperative C2-7 SVA was also negatively correlated with postoperative C2-7L and focal lordosis. Postoperative C2-7L was highly correlated with postoperative focal lordosis. For three or more levels of cervical degenerative disease, good clinical outcomes can be achieved. TDR may not be a good choice for large preoperative C2-7 SVA. HS provides good cervical range of motion and restores cervical lordosis and C2-7 SVA. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Comparative Analysis between Total Disc Replacement and Posterior Foraminotomy for Posterolateral Soft Disc Herniation with Unilateral Radiculopathy : Clinical and Biomechanical Results of a Minimum 5 Years Follow-up

    PubMed Central

    Kim, Kyoung-Tae; Cho, Dae-Chul; Sung, Joo-Kyung; Kim, Young-Baeg; Kim, Du Hwan

    2017-01-01

    Objective To compare the clinical outcomes and biomechanical effects of total disc replacement (TDR) and posterior cervical foraminotomy (PCF) and to propose relative inclusion criteria. Methods Thirty-five patients who underwent surgery between 2006 and 2008 were included. All patients had single-level disease and only radiculopathy. The overall sagittal balance and angle and height of a functional segmental unit (FSU; upper and lower vertebral body of the operative lesion) were assessed by preoperative and follow-up radiographs. C2–7 range of motion (ROM), FSU, and the adjacent segment were also checked. Results The clinical outcome of TDR (group A) was tended to be superior to that of PCF (group B) without statistical significance. In the group A, preoperative and postoperative upper adjacent segment level motion values were 8.6±2.3 and 8.4±2.0, and lower level motion values were 8.4±2.2 and 8.3±1.9. Preoperative and postoperative FSU heights were 37.0±2.1 and 37.1±1.8. In the group B, upper level adjacent segment motion values were 8.1±2.6 and 8.2±2.8, and lower level motion values were 6.5±3.3 and 6.3±3.1. FSU heights were 37.1±2.0 and 36.2±1.8. The postoperative FSU motion and height changes were significant (p<0.05). The patient’s satisfaction rates for surgery were 88.2% in group A and 88.8% in group B. Conclusion TDR and PCF have favorable outcomes in patients with unilateral soft disc herniation. However, patients have different biomechanical backgrounds, so the patient’s biomechanical characteristics and economic status should be understood and treated using the optimal procedure. PMID:28061490

  13. Biomechanical Effects of the Geometry of Ball-and-Socket Artificial Disc on Lumbar Spine: A Finite Element Study.

    PubMed

    Choi, Jisoo; Shin, Dong-Ah; Kim, Sohee

    2017-03-15

    A three-dimensional finite element model of intact lumbar spine was constructed and four surgical finite element models implanted with ball-and-socket artificial discs with four different radii of curvature were compared. To investigate biomechanical effects of the curvature of ball-and-socket artificial disc using finite element analysis. Total disc replacement (TDR) has been accepted as an alternative treatment because of its advantages over spinal fusion methods in degenerative disc disease. However, the influence of the curvature of artificial ball-and-socket discs has not been fully understood. Four surgical finite element models with different radii of curvature of ball-and-socket artificial discs were constructed. The range of motion (ROM) increased with decreasing radius of curvature in extension, flexion, and lateral bending, whereas it increased with increasing radius of curvature in axial torsion. The facet contact force was minimum with the largest radius of curvature in extension, flexion, and lateral bending, whereas it was maximum with the largest radius in axial torsion. It was also affected by the disc placement, more with posterior placement than anterior placement. The stress in L4 cancellous bone increased when the radius of curvature was too large or small. The geometry of ball-and-socket artificial disc significantly affects the ROM, facet contact force, and stress in the cancellous bone at the surgical level. The implication is that in performing TDR, the ball-and-socket design may not be ideal, as ROM and facet contact force are sensitive to the disc design, which may be exaggerated by the individual difference of anatomical geometry. N/A.

  14. Prospective, randomized multicenter study of cervical arthroplasty versus anterior cervical discectomy and fusion: 5-year results with a metal-on-metal artificial disc.

    PubMed

    Coric, Domagoj; Guyer, Richard D; Nunley, Pierce D; Musante, David; Carmody, Cameron; Gordon, Charles; Lauryssen, Carl; Boltes, Margaret O; Ohnmeiss, Donna D

    2018-03-01

    OBJECTIVE Seven cervical total disc replacement (TDR) devices have received FDA approval since 2006. These devices represent a heterogeneous assortment of implants made from various biomaterials with different biomechanical properties. The majority of these devices are composed of metallic endplates with a polymer core. In this prospective, randomized multicenter study, the authors evaluate the safety and efficacy of a metal-on-metal (MoM) TDR (Kineflex|C) versus anterior cervical discectomy and fusion (ACDF) in the treatment of single-level spondylosis with radiculopathy through a long-term (5-year) follow-up. METHODS An FDA-regulated investigational device exemption (IDE) pivotal trial was conducted at 21 centers across the United States. Standard validated outcome measures including the Neck Disability Index (NDI) and visual analog scale (VAS) for assessing pain were used. Patients were randomized to undergo TDR using the Kineflex|C cervical artificial disc or anterior cervical fusion using structural allograft and an anterior plate. Patients were evaluated preoperatively and at 6 weeks and 3, 6, 12, 24, 36, 48, and 60 months after surgery. Serum ion analysis was performed on a subset of patients randomized to receive the MoM TDR. RESULTS A total of 269 patients were enrolled and randomly assigned to undergo either TDR (136 patients) or ACDF (133 patients). There were no significant differences between the TDR and ACDF groups in terms of operative time, blood loss, or length of hospital stay. In both groups, the mean NDI scores improved significantly by 6 weeks after surgery and remained significantly improved throughout the 60-month follow-up (both p < 0.01). Similarly, VAS pain scores improved significantly by 6 weeks and remained significantly improved through the 60-month follow-up (both p < 0.01). There were no significant changes in outcomes between the 24- and 60-month follow-ups in either group. Range of motion in the TDR group decreased at 3 months but was significantly greater than the preoperative mean value at the 12- and 24-month follow-ups and remained significantly improved through the 60-month period. There were no significant differences between the 2 groups in terms of reoperation/revision surgery or device-/surgery-related adverse events. The serum ion analysis revealed cobalt and chromium levels significantly lower than the levels that merit monitoring. CONCLUSIONS Cervical TDR with an MoM device is safe and efficacious at the 5-year follow-up. These results from a prospective randomized study support that Kineflex|C TDR as a viable alternative to ACDF in appropriately selected patients with cervical radiculopathy. Clinical trial registration no.: NCT00374413 (clinicaltrials.gov).

  15. Prospective, Randomized Comparison of Cervical Total Disk Replacement Versus Anterior Cervical Fusion: Results at 48 Months Follow-up.

    PubMed

    Hisey, Michael S; Bae, Hyun W; Davis, Reginald J; Gaede, Steven; Hoffman, Greg; Kim, Kee D; Nunley, Pierce D; Peterson, Daniel; Rashbaum, Ralph F; Stokes, John; Ohnmeiss, Donna D

    2015-05-01

    This was a prospective, randomized, controlled multicenter trial. The purpose of this study was to compare clinical outcomes at 4-year follow-up of patients receiving cervical total disk replacement (TDR) with those receiving anterior cervical discectomy and fusion (ACDF). ACDF has been the traditional treatment for symptomatic disk degeneration. Several studies found single-level TDR to be as safe and effective as ACDF at ≥2 years follow-up. Patients from 23 centers were randomized in a 2:1 ratio with 164 receiving the investigational device (Mobi-C Cervical Disc Prosthesis) and 81 receiving ACDF using an anterior plate and allograft. Patients were evaluated preoperatively and 6 weeks, 3, 6, 12, 18, 24, 36, and 48 months postoperatively. Outcome assessments included a composite success score, Neck Disability Index, visual analog scales assessing neck and arm pain, patient satisfaction, major complications, subsequent surgery, segmental range of motion, and adjacent-segment degeneration. The composite success rate was similar in the 2 groups at 48-month follow-up. Mean Neck Disability Index, visual analog scale, and SF-12 scores were significantly improved in early follow-up in both groups with improvements maintained throughout 48 months. On some measures, TDR had significantly greater improvement during early follow-up. At no follow-up were TDR scores significantly worse than ACDF scores. Subsequent surgery rate was significantly higher for ACDF compared with TDR (9.9% vs. 3.0%, P<0.05). Range of motion was maintained with TDR having a mean baseline value of 8 degrees compared with 10 degrees at 48 months. The incidence of adjacent-segment degeneration was significantly higher with ACDF at inferior and superior segments compared with TDR (inferior: 50% vs. 30%, P<0.025; superior: 53% vs. 34%, P<0.025). Significant improvements were observed in pain and function. TDR patients maintained motion and had significantly lower rates of reoperation and adjacent-segment degeneration compared with ACDF. This study supports the safety and efficacy of TDR in appropriately selected patients.

  16. In vitro-analysis of kinematics and intradiscal pressures in cervical arthroplasty versus fusion--A biomechanical study in a sheep model with two semi-constrained prosthesis.

    PubMed

    Daentzer, Dorothea; Welke, Bastian; Hurschler, Christof; Husmann, Nathalie; Jansen, Christina; Flamme, Christian Heinrich; Richter, Berna Ida

    2015-03-24

    As an alternative technique to arthrodesis of the cervical spine, total disc replacement (TDR) has increasingly been used with the aim of restoration of the physiological function of the treated and adjacent motions segments. The purpose of this experimental study was to analyze the kinematics of the target level as well as of the adjacent segments, and to measure the pressures in the proximal and distal disc after arthrodesis as well as after arthroplasty with two different semi-constrained types of prosthesis. Twelve cadaveric ovine cervical spines underwent polysegmental (C2-5) multidirectional flexibility testing with a sensor-guided industrial serial robot. Additionally, pressures were recorded in the proximal and distal disc. The following three conditions were tested: (1) intact specimen, (2) single-level arthrodesis C3/4, (3) single-level TDR C3/4 using the Discover® in the first six specimens and the activ® C in the other six cadavers. Statistical analysis was performed for the total range of motion (ROM), the intervertebral ROM (iROM) and the intradiscal pressures (IDP) to compare both the three different conditions as well as the two disc prosthesis among each other. The relative iROM in the target level was always lowered after fusion in the three directions of motion. In almost all cases, the relative iROM of the adjacent segments was almost always higher compared to the physiologic condition. After arthroplasty, we found increased relative iROM in the treated level in comparison to intact state in almost all cases, with relative iROM in the adjacent segments observed to be lower in almost all situations. The IDP in both adjacent discs always increased in flexion and extension after arthrodesis. In all but five cases, the IDP in each of the adjacent level was decreased below the values of the intact specimens after TDR. Overall, in none of the analyzed parameters were statistically significantly differences between both types of prostheses investigated. The results of this biomechanical study indicate that single-level implantation of semi-constrained TDR lead to a certain hypermobility in the treated segments with lowering the ROM in the adjacent levels in almost all situations.

  17. Bone loss of vertebral bodies at the operative segment after cervical arthroplasty: a potential complication?

    PubMed

    Heo, Dong Hwa; Lee, Dong Chan; Oh, Jong Yang; Park, Choon Keun

    2017-02-01

    OBJECTIVE Bony overgrowth and spontaneous fusion are complications of cervical arthroplasty. In contrast, bone loss or bone remodeling of vertebral bodies at the operation segment after cervical arthroplasty has also been observed. The purpose of this study is to investigate a potential complication-bone loss of the anterior portion of the vertebral bodies at the surgically treated segment after cervical total disc replacement (TDR)-and discuss the clinical significance. METHODS All enrolled patients underwent follow-up for more than 24 months after cervical arthroplasty using the Baguera C disc. Clinical evaluations included recording demographic data and measuring the visual analog scale and Neck Disability Index scores. Radiographic evaluations included measurements of the functional spinal unit's range of motion and changes such as bone loss and bone remodeling. The grading of the bone loss of the operative segment was classified as follows: Grade 1, disappearance of the anterior osteophyte or small minor bone loss; Grade 2, bone loss of the anterior portion of the vertebral bodies at the operation segment without exposure of the artificial disc; or Grade 3, significant bone loss with exposure of the anterior portion of the artificial disc. RESULTS Forty-eight patients were enrolled in this study. Among them, bone loss developed in 29 patients (Grade 1 in 15 patients, Grade 2 in 6 patients, and Grade 3 in 8 patients). Grade 3 bone loss was significantly associated with postoperative neck pain (p < 0.05). Bone loss was related to the motion preservation effect of the operative segment after cervical arthroplasty in contrast to heterotopic ossification. CONCLUSIONS Bone loss may be a potential complication of cervical TDR and affect early postoperative neck pain. However, it did not affect mid- to long-term clinical outcomes or prosthetic failure at the last follow-up. Also, this phenomenon may result in the motion preservation effect in the operative segment after cervical TDR.

  18. Intermediate clinical and radiological results of cervical TDR (Mobi-C®) with up to 2 years of follow-up

    PubMed Central

    Beaurain, J.; Bernard, P.; Dufour, T.; Fuentes, J. M.; Hovorka, I.; Huppert, J.; Steib, J. P.; Vital, J. M.; Aubourg, L.

    2009-01-01

    The interest in cervical total disc replacement (TDR) as an alternative to the so-far gold standard in the surgical treatment of degenerative disc disease (DDD), e.g anterior cervical discectomy and fusion (ACDF), is growing very rapidly. Many authors have established the fact that ACDF may result in progressive degeneration in adjacent segments. On the contrary, but still theoretically, preservation of motion with TDR at the surgically treated level may potentially reduce the occurrence of adjacent-level degeneration (ALD). The authors report the intermediate results of an undergoing multicentre prospective study of TDR with Mobi-C® prosthesis. The aim of the study was to assess the safety and efficacy of the device in the treatment of DDD and secondary to evaluate the radiological status of adjacent levels and the occurrence of ossifications, at 2-year follow-up (FU). 76 patients have performed their 2-year FU visit and have been analyzed clinically and radiologically. Clinical outcomes (NDI, VAS, SF-36) and ROM measurements were analyzed pre-operatively and at the different post-operative time-points. Complications and re-operations were also assessed. Occurrences of heterotopic ossifications (HOs) and of adjacent disc degeneration radiographic changes have been analyzed from 2-year FU X-rays. The mean NDI and VAS scores for arm and neck are reduced significantly at each post-operative time-point compared to pre-operative condition. Motion is preserved over the time at index levels (mean ROM = 9° at 2 years) and 85.5% of the segments are mobile at 2 years. HOs are responsible for the fusion of 6/76 levels at 2 years. However, presence of HO does not alter the clinical outcomes. The occurrence rate of radiological signs of ALD is very low at 2 years (9.1%). There has been no subsidence, no expulsion and no sub-luxation of the implant. Finally, after 2 years, 91% of the patients assume that they would undergo the procedure again. These intermediate results of TDR with Mobi-C® are very encouraging and seem to confirm the efficacy and the safety of the device. Regarding the preservation of the status of the adjacent levels, the results of this unconstrained device are encouraging, but longer FU studies are needed to prove it. PMID:19434431

  19. Comparison of biomechanical function at ideal and varied surgical placement for two lumbar artificial disc implant designs: mobile-core versus fixed-core.

    PubMed

    Moumene, Missoum; Geisler, Fred H

    2007-08-01

    Finite element model. To estimate the effect of lumbar mobile-core and fixed-core artificial disc design and placement on the loading of the facet joints, and stresses on the polyethylene core. Although both mobile-core and fixed-core lumbar artificial disc designs have been used clinically, the effect of their design and the effect of placement within the disc space on the structural element loading, and in particular the facets and the implant itself, have not been investigated. A 3D nonlinear finite element model of an intact ligamentous L4-L5 motion segment was developed and validated in all 6 df based on previous experiments conducted on human cadavers. Facet loading of a mobile-core TDR and a fixed-core TDR were estimated with 4 different prosthesis placements for 3 different ranges of motion. Placing the mobile-core TDR anywhere within the disc space reduced facet loading by more than 50%, while the fixed-core TDR increased facet loading by more than 10% when compared with the intact disc in axial rotation. For central (ideal) placement, the mobile- and fixed-core implants were subjected to compressive stresses on the order of 3 MPa and 24 MPa, respectively. The mobile-core stresses were not affected by implant placement, while the fixed-core stresses increased by up to 40%. A mobile-core artificial disc design is less sensitive to placement, and unloads the facet joints, compared with a fixed-core design. The decreased core stress may result in a reduced potential for wear in a mobile-core prosthesis compared with a fixed-core prosthesis, which may increase the functional longevity of the device.

  20. Results of the prospective, randomized, controlled multicenter Food and Drug Administration investigational device exemption study of the ProDisc-C total disc replacement versus anterior discectomy and fusion for the treatment of 1-level symptomatic cervical disc disease.

    PubMed

    Murrey, Daniel; Janssen, Michael; Delamarter, Rick; Goldstein, Jeffrey; Zigler, Jack; Tay, Bobby; Darden, Bruce

    2009-04-01

    Cervical total disc replacement (TDR) is intended to address radicular pain and preserve functional motion between two vertebral bodies in patients with symptomatic cervical disc disease (SCDD). The purpose of this trial is to compare the safety and efficacy of cervical TDR, ProDisc-C (Synthes Spine Company, L.P., West Chester, PA), to anterior cervical discectomy and fusion (ACDF) surgery for the treatment of one-level SCDD between C3 and C7. The study was conducted at 13 sites. A noninferiority design with a 1:1 randomization was used. Two hundred nine patients were randomized and treated (106 ACDF; 103 ProDisc-C). Visual analog scale (VAS) pain and intensity (neck and arm), VAS satisfaction, neck disability index (NDI), neurological exam, device success, adverse event occurrence, and short form-36 (SF-36) standardized questionnaires. A prospective, randomized, controlled clinical trial was performed. Patients were enrolled and treated in accordance with the US Food and Drug Administration (FDA)-approved protocol. Patients were assessed pre- and postoperatively at six weeks, 3, 6, 12, 18, and 24 months. Demographics were similar between the two patient groups (ProDisc-C: 42.1+/-8.4 years, 44.7% males; Fusion: 43.5 +/- 7.1 years, 46.2% males). The most commonly treated level was C5-C6 (ProDisc-C: 56.3%; Fusion=57.5%). NDI and SF-36 scores were significantly less compared with presurgery scores at all follow-up visits for both the treatment groups (p<.0001). VAS neck pain intensity and frequency as well as VAS arm pain intensity and frequency were statistically lower at all follow-up timepoints compared with preoperative levels (p<.0001) but were not different between treatments. Neurologic success (improvement or maintenance) was achieved at 24 months in 90.9% of ProDisc-C and 88.0% of Fusion patients (p=.638). Results show that at 24 months postoperatively, 84.4% of ProDisc-C patients achieved a more than or equal to 4 degrees of motion or maintained motion relative to preoperative baseline at the operated level. There was a statistically significant difference in the number of secondary surgeries with 8.5% of Fusion patients needing a re-operation, revision, or supplemental fixation within the 24 month postoperative period compared with 1.8% of ProDisc-C patients (p=.033). At 24 months, there was a statistically significant difference in medication usage with 89.9% of ProDisc-C patients not on strong narcotics or muscle relaxants, compared with 81.5% of Fusion patients. The results of this clinical trial demonstrate that ProDisc-C is a safe and effective surgical treatment for patients with disabling cervical radiculopathy because of single-level disease. By all primary and secondary measures evaluated, clinical outcomes after ProDisc-C implantation were either equivalent or superior to those same clinical outcomes after Fusion.

  1. Interaction of micron and nano-sized particles with cells of the dura mater.

    PubMed

    Papageorgiou, Iraklis; Marsh, Rainy; Tipper, Joanne L; Hall, Richard M; Fisher, John; Ingham, Eileen

    2014-10-01

    Intervertebral total disc replacements (TDR) are used in the treatment of degenerative spinal disc disease. There are, however, concerns that they may be subject to long-term failure due to wear. The adverse effects of TDR wear have the potential to manifest in the dura mater and surrounding tissues. The aim of this study was to investigate the physiological structure of the dura mater, isolate the resident dural epithelial and stromal cells and analyse the capacity of these cells to internalise model polymer particles. The porcine dura mater was a collagen-rich structure encompassing regularly arranged fibroblastic cells within an outermost epithelial cell layer. The isolated dural epithelial cells had endothelial cell characteristics (positive for von Willebrand factor, CD31, E-cadherin and desmoplakin) and barrier functionality whereas the fibroblastic cells were positive for collagen I and III, tenascin and actin. The capacity of the dural cells to take up model particles was dependent on particle size. Nanometer sized particles readily penetrated both types of cells. However, dural fibroblasts engulfed micron-sized particles at a much higher rate than dural epithelial cells. The study suggested that dural epithelial cells may offer some barrier to the penetration of micron-sized particles but not nanometer sized particles. © 2014 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  2. Clinical outcomes, radiologic kinematics, and effects on sagittal balance of the 6 df LP-ESP lumbar disc prosthesis.

    PubMed

    Lazennec, Jean-Yves; Even, Julien; Skalli, Wafa; Rakover, Jean-Patrick; Brusson, Adrien; Rousseau, Marc-Antoine

    2014-09-01

    Surgical treatment of degenerative disc disease remains a controversial subject. Lumbar fusion has been associated with a potential risk of segmental junctional disease and sagittal balance misalignment. Motion preservation devices have been developed as an alternative to fusion. The LP-ESP disc is a one-piece deformable device achieving 6 df, including shock absorption and elastic return. This is the first clinical report on its use. To assess clinical outcomes and radiologic kinematics in the first 2 years after implantation. Prospective cohort of patients with LP-ESP total disc replacement (TDR) at the lumbar spine. Forty-six consecutive patients. Clinical outcomes were the visual analog scale (VAS) for pain, the Oswestry disability index (ODI), and the GHQ28 (General Health Questionnaire) psychological score. Radiologic data were the range of motion (ROM), sagittal balance parameters, and mean center of rotation (MCR). Patients had single-level TDR at L4-L5 or L5-S1. Outcomes were prospectively recorded for 2 years (before and at 3, 6, 12, and 24 months after surgery). The SpineView software was used for computed analysis of the radiographic data. Paired t tests were used for statistical comparisons. No intraoperative complication occurred. All clinical scores improved significantly at 24 months: the back pain VAS scores by a mean of 4.1 points and the ODI by 33 points. The average ROM of the instrumented level was 5.4°±4.8° at 2 years and more than 2° for 76% of prostheses. The MCR was in a physiological area in 73% of cases. The sagittal balance (pelvic tilt, sacral slope, and segmental lordosis) did not change significantly at any point of the follow-up. Results from the 2-year follow-up indicate that LP-ESP prosthesis recreates lumbar spine function similar to that of the healthy disc in terms of ROM, quality of movement, effect on sagittal balance, and absence of modification in the kinematics of the upper adjacent level. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Interaction of micron and nano-sized particles with cells of the dura mater

    PubMed Central

    Papageorgiou, Iraklis; Marsh, Rainy; Tipper, Joanne L; Hall, Richard M; Fisher, John; Ingham, Eileen

    2014-01-01

    Intervertebral total disc replacements (TDR) are used in the treatment of degenerative spinal disc disease. There are, however, concerns that they may be subject to long-term failure due to wear. The adverse effects of TDR wear have the potential to manifest in the dura mater and surrounding tissues. The aim of this study was to investigate the physiological structure of the dura mater, isolate the resident dural epithelial and stromal cells and analyse the capacity of these cells to internalise model polymer particles. The porcine dura mater was a collagen-rich structure encompassing regularly arranged fibroblastic cells within an outermost epithelial cell layer. The isolated dural epithelial cells had endothelial cell characteristics (positive for von Willebrand factor, CD31, E-cadherin and desmoplakin) and barrier functionality whereas the fibroblastic cells were positive for collagen I and III, tenascin and actin. The capacity of the dural cells to take up model particles was dependent on particle size. Nanometer sized particles readily penetrated both types of cells. However, dural fibroblasts engulfed micron-sized particles at a much higher rate than dural epithelial cells. The study suggested that dural epithelial cells may offer some barrier to the penetration of micron-sized particles but not nanometer sized particles. © 2014 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 1496–1505, 2014. PMID:24604838

  4. Biomechanics of the L5-S1 motion segment after total disc replacement - Influence of iatrogenic distraction, implant positioning and preoperative disc height on the range of motion and loading of facet joints.

    PubMed

    Dreischarf, Marcel; Schmidt, Hendrik; Putzier, Michael; Zander, Thomas

    2015-09-18

    Total disc replacement has been introduced to overcome negative side effects of spinal fusion. The amount of iatrogenic distraction, preoperative disc height and implant positioning have been considered important for surgical success. However, their effect on the postoperative range of motion (RoM) and loading of the facets merits further discussion. A validated osteoligamentous finite element model of the lumbosacral spine was employed and extended with four additional models to account for different disc heights. An artificial disc with a fixed center of rotation (CoR) was implemented in L5-S1. In 4000 simulations, the influence of distraction and the CoR's location on the RoM, facet joint forces (FJFs) and facet capsule ligament forces (FCLFs) was investigated. Distraction substantially altered segmental kinematics in the sagittal plane by decreasing range of flexion (0.5° per 1mm of distraction), increasing range of extension (0.7°/mm) and slightly affecting complete sagittal RoM (0.2°/mm). The distraction already strongly increased the FCLFs during surgery (up to 230N) and in flexion (~12N/mm), with higher values in models with larger preoperative disc heights, and increased FJFs in extension. A more anterior implant location decreased the RoM in all planes. In most loading cases, a more posterior location of the implant's CoR increased the FJFs and FCLFs, whereas a more caudal location increased the FCLFs but decreased the FJFs. The results of this study may explain the worse clinical results in patients with overdistraction after TDR. The complete RoM in the sagittal plane appears to be insensitive to detecting surgery-related biomechanical changes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.

    PubMed

    Siskey, Ryan; Ciccarelli, Lauren; Lui, Melissa K C; Kurtz, Steven M

    2016-11-01

    Most contemporary total disc replacements (TDRs) use conventional orthopaedic bearing couples such as ultrahigh-molecular-weight polyethylene (polyethylene) and cobalt-chromium (CoCr). Cervical total disc replacements incorporating polyetheretherketone (PEEK) bearings (specifically PEEK-on-PEEK bearings) have been previously investigated, but little is known about PEEK-on-ceramic bearings for TDR. (1) What is the tribologic behavior of a PEEK-on-ceramic bearing for cervical TDR under idealized, clean wear test conditions? (2) How does the PEEK-on-ceramic design perform under impingement conditions? (3) How is the PEEK-on-ceramic bearing affected by abrasive wear? (4) Is the particle morphology from PEEK-on-ceramic bearings for TDRs affected by adverse wear scenarios? PEEK-on-ceramic cervical TDR bearings were subjected to a 10 million cycle ideal wear test based on ASTM F2423 and ISO 181912-1 using a six-station spine wear simulator (MTS, Eden Prairie, MN, USA) with 5 g/L bovine serum concentration at 23° ± 2° C (ambient temperature). Validated 1 million cycle impingement and 5 million cycle abrasive tests were conducted on the PEEK-on-ceramic bearings based, in part, on retrieval analysis of a comparable bearing design as well as finite element analyses. The ceramic-on-PEEK couple was characterized for damage modes, mass and volume loss, and penetration and the lubricant was subjected to particle analysis. The resulting mass wear rate, volumetric wear rate, based on material density, and particle analysis were compared with clinically available cervical disc bearing couples. The three modes of wear (idealized, impingement, and abrasive) resulted in mean mass wear rates of 0.9 ± 0.2 mg/MC, 1.9 ± 0.5 mg/MC, and 2.8 ± 0.6 mg/MC, respectively. The mass wear rates were converted to volumetric wear rates using density and found to be 0.7 ± 0.1 mm 3 /MC, 1.5 ± 0.4 mm 3 /MC, and 2.1 ± 0.5 mm 3 /MC, respectively. During each test, the PEEK endplates were the primary sources of wear and demonstrated an abrasive wear mechanism. Under idealized and impingement conditions, the ceramic core also demonstrated slight polishing of the articulating surface but the change in mass was unmeasurable. During abrasive testing, the titanium transfer on the core was shown to polish over 5 MC of testing. In all cases and consistent with previous studies of other PEEK bearing couples, the particle size was primarily < 2 µm and morphology was smooth and spheroidal. Overall, the idealized PEEK-on-ceramic wear rate (0.7 ± 0.1 mm 3 /MC) appears comparable to the published wear rates for other polymer-on-hard bearing couples (0.3-6.7 mm 3 /MC) and within the range of 0.2 to 1.9 mm 3 /MC reported for PEEK-on-PEEK cervical disc designs. The particles, based on size and morphology, also suggest the wear mechanism is comparable between the PEEK-on-ceramic couple and other polymer-on-ceramic orthopaedic couples. The PEEK-on-ceramic bearing considered in this study is a novel bearing couple for use in total disc arthroplasty devices and will require clinical evaluation to fully assess the bearing couple and total disc design. However, the wear rates under idealized and adverse conditions, and particle size and morphology, suggest that PEEK-on-ceramic bearings may be a reasonable alternative to polyethylene-on-CoCr and metal-on-metal bearings currently used in cervical TDRs.

  6. Comparison of revision surgeries for one- to two-level cervical TDR and ACDF from 2002 to 2011.

    PubMed

    Nandyala, Sreeharsha V; Marquez-Lara, Alejandro; Fineberg, Steven J; Singh, Kern

    2014-12-01

    Cervical total disc replacement (TDR) and anterior cervical discectomy and fusion (ACDF) provide comparable outcomes for degenerative cervical pathology. However, revisions of these procedures are not well characterized. The purpose of this study is to examine the rates, epidemiology, perioperative complications, and costs between the revision procedures and to compare these outcomes with those of primary cases. This study is a retrospective database analysis. A total of 3,792 revision and 183,430 primary cases from the Nationwide Inpatient Sample (NIS) database from 2002 to 2011 were included. Incidence of revision cases, patient demographics, length of stay (LOS), in-hospital costs, mortality, and perioperative complications. Patients who underwent revision for either one- to two-level cervical TDR or ACDF were identified. SPSS v.20 was used for statistical analysis with χ(2) test for categorical data and independent sample t test for continuous data. The relative risk for perioperative complications with revisions was calculated in comparison with primary cases using a 95% confidence interval. An alpha level of less than 0.05 denoted statistical significance. There were 3,536 revision one- to two-level ACDFs and 256 revision cervical TDRs recorded in the NIS database from 2002 to 2011. The revision cervical TDR cohort demonstrated a significantly greater LOS (3.18 vs. 2.25, p<.001), cost ($16,998 vs. $15,222, p=.03), and incidence of perioperative wound infections (13.6 vs. 5.3 per 1,000, p<.001) compared with the ACDF revision cohort (p<.001). There were no differences in mortality between the revision surgical cohorts. Compared with primary cases, both revision cohorts demonstrated a significantly greater LOS and cost. Furthermore, patients who underwent revision demonstrated a greater incidence and risk for perioperative wound infections, hematomas, dysphagia, and neurologic complications relative to the primary procedures. This study demonstrated a significantly greater incidence of perioperative wound infection, LOS, and costs associated with a TDR revision compared with a revision ACDF. We propose that these differences are by virtue of the inherently more invasive nature of revising TDRs. In addition, compared with primary cases, revision procedures are associated with greater costs, LOS, and complications including wound infections, dysphagia, hematomas, and neurologic events. These additional risks must be considered before opting for a revision procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Clinical experience and two-year follow-up with a one-piece viscoelastic cervical total disc replacement.

    PubMed

    Chin, Kingsley Richard; Lubinski, Jacob Ryan; Zimmers, Kari Bracher; Sands, Barry Eugene; Pencle, Fabio

    2017-12-01

    The purpose of this study is to present clinical outcome data from a 2-year post-market study of a viscoelastic one-piece cervical total disc replacement (TDR) in Europe. Thirty-nine patients were implanted at five surgical sites in an European post-market clinical study. Clinical outcomes included improvement of neck disability index (NDI) and visual analog scale scores for neck and arm pain from baseline to 2-year follow-up, neurological examinations, patients view on the success of surgery, complications, and subsequent surgical interventions. Thirty patients had the Freedom ® Cervical Disc (FCD) implanted at a single level, and nine patients were implanted at two adjacent levels. The population had a similar distribution of male [20] and female [19] subjects, with a mean age of 45 years. All self-administered outcome measures showed significant clinically important improvements from baseline to the 2-year follow-up. Mean preoperative NDI score improved from 48% to 20%, 13%, 8%, 6% and 4% at 6 weeks, 3, 6, 12, and 24 months, respectively. Average preoperative visual analog scale (VAS) scores of the neck, right and left arm pain intensity and frequency showed significant improvement. All neurological outcome measurements showed immediate improvement from preoperative values and continued improvement throughout 2 years follow-up. From pre-op to 24 months, neurological deficits declined in the population from 21% to 6% for reflex function, 62% to 17% for sensory function, and 38% to 3% for motor function. No patients experienced a deterioration in any measured outcomes compared with the preoperative situation. Patient satisfaction increased over 2 years post-op, with 83% of patients responding that they would "definitely" choose to have the same treatment for their neck/arm condition and another 11% responding that they would "probably" choose to have the same treatment. The FCD performs as expected in patients with single-level and two-level degenerative disc disease.

  8. ALIF and total disc replacement versus 2-level circumferential fusion with TLIF: a prospective, randomized, clinical and radiological trial.

    PubMed

    Hoff, Eike K; Strube, Patrick; Pumberger, Matthias; Zahn, Robert K; Putzier, Michael

    2016-05-01

    Prospective, randomized trial. The treatment of degenerative disc disease (DDD) with two-level fusion has been associated with a reasonable rate of complications. The aim of the present study was to compare (Hybrid) stand-alone anterior lumbar interbody fusion (ALIF) at L5/S1 with total disc replacement at L4/5 (TDR) as an alternative surgical strategy to (Fusion) 2-level circumferential fusion employing transforaminal lumbar interbody fusion (TLIF) with transpedicular stabilization at L4-S1. A total of 62 patients with symptomatic DDD of segments L5/S1 (Modic ≥2°) and L4/5 (Modic ≤2°; positive discography) were enrolled; 31 were treated with Hybrid and 31 with Fusion. Preoperatively, at 0, 12, and a mean follow-up of 37 months, clinical (ODI, VAS) and radiological evaluations (plain/extension-flexion radiographs evaluated for implant failure, fusion, global and segmental lordosis, and ROM) were performed. In 26 of 31 Hybrid and 24 of 31 Fusion patients available at the final follow-up, we found a significant clinical improvement compared to preoperatively. Hybrid patients had significantly lower VAS scores immediately postoperatively and at follow-up compared to Fusion patients. The complication rates were low and similar between the groups. Lumbar lordosis increased in both groups. The increase was mainly located at L4-S1 in the Hybrid group and at L1-L4 in the Fusion group. Hybrid patients presented with increased ROM at L4/5 and L3/4, and Fusion patients presented with increased ROM at L3/4, with significantly greater ROM at L3/4 compared to Hybrid patients at follow-up. Hybrid surgery is a viable surgical alternative for the presented indication. Approach-related inferior trauma and the balanced restoration of lumbar lordosis resulted in superior clinical outcomes compared to two-level circumferential fusion with TLIF.

  9. Adjacent level effects of bi level disc replacement, bi level fusion and disc replacement plus fusion in cervical spine--a finite element based study.

    PubMed

    Faizan, Ahmad; Goel, Vijay K; Biyani, Ashok; Garfin, Steven R; Bono, Christopher M

    2012-03-01

    Studies delineating the adjacent level effect of single level disc replacement systems have been reported in literature. The aim of this study was to compare the adjacent level biomechanics of bi-level disc replacement, bi-level fusion and a construct having adjoining level disc replacement and fusion system. In total, biomechanics of four models- intact, bi level disc replacement, bi level fusion and fusion plus disc replacement at adjoining levels- was studied to gain insight into the effects of various instrumentation systems on cranial and caudal adjacent levels using finite element analysis (73.6N+varying moment). The bi-level fusion models are more than twice as stiff as compared to the intact model during flexion-extension, lateral bending and axial rotation. Bi-level disc replacement model required moments lower than intact model (1.5Nm). Fusion plus disc replacement model required moment 10-25% more than intact model, except in extension. Adjacent level motions, facet loads and endplate stresses increased substantially in the bi-level fusion model. On the other hand, adjacent level motions, facet loads and endplate stresses were similar to intact for the bi-level disc replacement model. For the fusion plus disc replacement model, adjacent level motions, facet loads and endplate stresses were closer to intact model rather than the bi-level fusion model, except in extension. Based on our finite element analysis, fusion plus disc replacement procedure has less severe biomechanical effects on adjacent levels when compared to bi-level fusion procedure. Bi-level disc replacement procedure did not have any adverse mechanical effects on adjacent levels. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Effect of multilevel lumbar disc arthroplasty on the operative- and adjacent-level kinematics and intradiscal pressures: an in vitro human cadaveric assessment.

    PubMed

    Dmitriev, Anton E; Gill, Norman W; Kuklo, Timothy R; Rosner, Michael K

    2008-01-01

    With lumbar arthroplasty gaining popularity, limited data are available highlighting changes in adjacent-level mechanics after multilevel procedures. Compare operative- and adjacent-segment range of motion (ROM) and intradiscal pressures (IDPs) after two-level arthroplasty versus circumferential arthrodesis. Cadaveric biomechanical study. Ten human cadaveric lumbar spines were used in this investigation. Biomechanical testing was performed according to a hybrid testing protocol using an unconstrained spine simulator under axial rotation (AR), flexion extension (FE), and lateral-bending (LB) loading. Specimens were tested in the following order: 1) Intact, 2) L3-L5 total disc replacement (TDR), 3) L3-L5 anterior interbody cages+pedicle screws. IDP was recorded at proximal and distal adjacent levels and normalized to controls (%intact). Full ROM was monitored at the operative and adjacent levels and reported in degrees. Kinematics assessment revealed L3-L5 ROM reduction after both reconstructions versus intact controls (p < .05). However, global quality of segmental motion distributed over L2-S1 was preserved in the arthroplasty group but was significantly altered after circumferential fixation. Furthermore, adjacent-level ROM was increased for the arthrodesis group under LB at both segments and during AR at L2-L3 relative to controls (p < .05). FE did not reveal any intergroup statistical differences. Nonetheless, after arthrodesis IDPs were increased proximally under all three loading modalities, whereas distally a significant IDP rise was noted during AR and LB (p < .05). No statistical differences in either biomechanical parameter were recorded at the adjacent levels between intact control and TDR groups. Our results indicate no significant adjacent-level biomechanical changes between arthroplasty and control groups. In contrast, significant alterations in ROM and IDP were recorded both proximally (ROM=LB & AR; IDP=AR, FE, LB) and distally (ROM=LB; IDP=AR & LB) after circumferential arthrodesis. Therefore, two-level lumbar arthroplasty maintains a more favorable biomechanical environment at the adjacent segments compared with the conventional transpedicular fixation technique. This, in turn, may have a positive effect on the rate of the transition syndrome postoperatively.

  11. Kinematics of a selectively constrained radiolucent anterior lumbar disc: comparisons to hybrid and circumferential fusion.

    PubMed

    Daftari, Tapan K; Chinthakunta, Suresh R; Ingalhalikar, Aditya; Gudipally, Manasa; Hussain, Mir; Khalil, Saif

    2012-10-01

    Despite encouraging clinical outcomes of one-level total disc replacements reported in literature, there is no compelling evidence regarding the stability following two-level disc replacement and hybrid constructs. The current study is aimed at evaluating the multidirectional kinematics of a two-level disc arthroplasty and hybrid construct with disc replacement adjacent to rigid circumferential fusion, compared to two-level fusion using a novel selectively constrained radiolucent anterior lumbar disc. Nine osteoligamentous lumbosacral spines (L1-S1) were tested in the following sequence: 1) Intact; 2) One-level disc replacement; 3) Hybrid; 4) Two-level disc replacement; and 5) Two-level fusion. Range of motion (at both implanted and adjacent level), and center of rotation in sagittal plane were recorded and calculated. At the level of implantation, motion was restored when one-level disc replacement was used but tended to decrease with two-level disc arthroplasty. The findings also revealed that both one-level and two-level disc replacement and hybrid constructs did not significantly change adjacent level kinematics compared to the intact condition, whereas the two-level fusion construct demonstrated a significant increase in flexibility at the adjacent level. The location of center of rotation in the sagittal plane at L4-L5 for the one-level disc replacement construct was similar to that of the intact condition. The one-level disc arthroplasty tended to mimic a motion profile similar to the intact spine. However, the two-level disc replacement construct tended to reduce motion and clinical stability of a two-level disc arthroplasty requires additional investigation. Hybrid constructs may be used as a surgical alternative for treating two-level lumbar degenerative disc disease. Published by Elsevier Ltd.

  12. Physiotherapeutic Rehabilitation Following Lumbar Total Disc Replacement: A Retrospective Study.

    PubMed

    Green, Adeline; Gilbert, Philippa; Scott-Young, Matthew; Abbott, Allan

    2016-09-01

    This study sought to answer the following questions: What are the outcomes of physiotherapy post lumbar total disc replacement (LTDR) compared with patient self-mediated rehabilitation? Is a difference in outcomes related to the number of physiotherapy sessions? This is a retrospective observational study of 600 patients post TDR. Patient outcomes for self-mediated rehabilitation (Group 1), 1-3 sessions of clinic-based physiotherapy (Group 2) and ≥4 sessions of clinic-based physiotherapy (Group 3) were analysed. Outcomes measures included the Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMQ), Short Form-36 Physical (SF-36 PCS) and Mental Subscale Components (SF-36 MCS), Visual Analogue Scale (VAS) for back and leg pain intensity. Patient's pre-operative baseline measures and post-operative follow-up measures at 3, 6, 12 and 24 months post-operatively were analysed. Oswestry Disability Index and RMQ had significantly lower scores in Group 3 compared with Group 1 at 3, 6, 12 and 24 months follow-up. Significantly lower scores for Group 2 compared with Group 1 were observed for the ODI at 3 months follow-up and for the RMQ at 3 and 6 months follow-up. Significantly lower scores were observed in Group 3 compared with Group 1 for VAS back pain at 3 months and VAS leg pain at 6 months follow-up. Significantly higher scores in Group 3 compared with Group 1 were also observed in the SF-36 PCS at 6, 12 and 24 months. Significantly higher scores in Group 2 compared with Group 1 were observed at 6 months follow up. These trends were also observed when investigating the percentage of patients with a greater 50% improvement in the outcome measure. Physiotherapy post-LTDR produces statistically significant and possibly clinically important improvements in functional disability, pain and quality of life outcomes compared with self-mediated rehabilitation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Foreword: Proceedings From the First Annual Lumbar Total Disc Replacement Summit.

    PubMed

    Blumenthal, Scott; Buttermann, Glenn; Garcia, Rolando; Gornet, Matthew; Grunch, Betsy; Guyer, Richard; Janssen, Michael; Kimball, Brent; Lewis, Adam; Mesiwala, Ali; Miller, Lynn; Morreale, Joseph; Reed, William; Sandhu, Faheem; Shackleford, Ian; Yue, James; Zigler, Jack; OConnell, Brent; Ferko, Nicole; Hollmann, Sarah

    2017-12-15

    : This publication focuses on proceedings from the First Annual Lumbar Total Disc Replacement Summit, held October 25, 2016 in Boston, MA. The Summit brought together 17 thought leading surgeons who employed a modified-Delphi method to determine where consensus existed pertaining to the utilization of lumbar total disc replacement as a standard of care for a subpopulation of patients suffering from degenerative disc disease.

  14. Quantification of soil water evaporation using TDR-microlysimetry

    USDA-ARS?s Scientific Manuscript database

    Soil water evaporation is conventionally measured using microlysimeters by evaluating the daily change in mass. Daily removal is laborious and replacement immediately after irrigation events is impractical because of field wetness which leads to delays and an underestimation of evaporation. Irrigati...

  15. In vitro and in silico investigations of disc nucleus replacement

    PubMed Central

    Reitmaier, Sandra; Shirazi-Adl, Aboulfazl; Bashkuev, Maxim; Wilke, Hans-Joachim; Gloria, Antonio; Schmidt, Hendrik

    2012-01-01

    Currently, numerous hydrogels are under examination as potential nucleus replacements. The clinical success, however, depends on how well the mechanical function of the host structure is restored. This study aimed to evaluate the extent to and mechanisms by which surgery for nucleus replacements influence the mechanical behaviour of the disc. The effects of an annulus defect with and without nucleus replacement on disc height and nucleus pressure were measured using 24 ovine motion segments. The following cases were considered: intact; annulus incision repaired by suture and glue; annulus incision with removal and re-implantation of nucleus tissue repaired by suture and glue or plug. To identify the likely mechanisms observed in vitro, a finite-element model of a human disc (L4–L5) was employed. Both studies were subjected to physiological cycles of compression and recovery. A repaired annulus defect did not influence the disc behaviour in vitro, whereas additional nucleus removal and replacement substantially decreased disc stiffness and nucleus pressure. Model predictions demonstrated the substantial effects of reductions in replaced nucleus water content, bulk modulus and osmotic potential on disc height loss and pressure, similar to measurements. In these events, the compression load transfer in the disc markedly altered by substantially increasing the load on the annulus when compared with the nucleus. The success of hydrogels for nucleus replacements is not only dependent on the implant material itself but also on the restoration of the environment perturbed during surgery. The substantial effects on the disc response of disruptions owing to nucleus replacements can be simulated by reduced nucleus water content, elastic modulus and osmotic potential. PMID:22337630

  16. Engineered disc-like angle-ply structures for intervertebral disc replacement.

    PubMed

    Nerurkar, Nandan L; Sen, Sounok; Huang, Alice H; Elliott, Dawn M; Mauck, Robert L

    2010-04-15

    To develop a construction algorithm in which electrospun nanofibrous scaffolds are coupled with a biocompatible hydrogel to engineer a mesenchymal stem cell (MSC)-based disc replacement. To engineer a disc-like angle-ply structure (DAPS) that replicates the multiscale architecture of the intervertebral disc. Successful engineering of a replacement for the intervertebral disc requires replication of its mechanical function and anatomic form. Despite many attempts to engineer a replacement for ailing and degenerated discs, no prior study has replicated the multiscale hierarchical architecture of the native disc, and very few have assessed the mechanical function of formed neo-tissues. A new algorithm for the construction of a disc analogue was developed, using agarose to form a central nucleus pulposus (NP) and oriented electrospun nanofibrous scaffolds to form the anulus fibrosus region (AF). Bovine MSCs were seeded into both regions and biochemical, histologic, and mechanical maturation were evaluated with in vitro culture. We show that mechanical testing in compression and torsion, loading methods commonly used to assess disc mechanics, reveal equilibrium and time-dependent behaviors that are qualitatively similar to native tissue, although lesser in magnitude. Further, we demonstrate that cells seeded into both AF and NP regions adopt distinct morphologies that mirror those seen in native tissue, and that, in the AF region, this ordered community of cells deposit matrix that is organized in an angle-ply configuration. Finally, constructs demonstrate functional development with long-term in vitro culture. These findings provide a new approach for disc tissue engineering that replicates multi-scale form and function of the intervertebral disc, providing a foundation from which to build a multi-scale, biologic, anatomically and hierarchically relevant composite disc analogue for eventual disc replacement.

  17. Translation of an Engineered Nanofibrous Disc-like Angle Ply Structure for Intervertebral Disc Replacement in a Small Animal Model

    PubMed Central

    Martin, John T.; Milby, Andrew H.; Chiaro, Joseph A.; Kim, Dong Hwa; Hebela, Nader M.; Smith, Lachlan J.; Elliott, Dawn M.; Mauck, Robert L.

    2015-01-01

    Intervertebral disc degeneration has been implicated in the etiology of low back pain; however the current surgical strategies for treating symptomatic disc disease are limited. A variety of materials have been developed to replace disc components, including the nucleus pulposus (NP), the annulus fibrosus (AF), and their combination into disc-like engineered constructs. We have previously shown that layers of electrospun poly(ε-caprolactone) scaffold, mimicking the hierarchical organization of the native AF, have functional parity with native tissue. Likewise, we have combined these structures with cell-seeded hydrogels (as an NP replacement) to form disc-like angle ply structures (DAPS). The objective of this study was to develop a model for the evaluation of DAPS in vivo. Through a series of studies, we developed a surgical approach to replace the rat caudal disc with an acellular DAPS and then stabilize the motion segment by external fixation. We then optimized cell infiltration into DAPS by including sacrificial poly(ethylene oxide) layers interspersed throughout the angle-ply structure. Our findings illustrate that DAPS are stable in the caudal spine, are infiltrated by cells from the peri-implant space, and that infiltration is expedited by providing additional routes for cell migration. These findings establish a new in vivo platform in which to evaluate and optimize the design of functional disc replacements. PMID:24560621

  18. Ulf Fernström (1915-1985) and his Contributions to the Development of Artificial Disc Replacements.

    PubMed

    Fisahn, Christian; Burgess, Brittni; Iwanaga, Joe; Chapman, Jens R; Oskouian, Rod J; Tubbs, R Shane

    2017-02-01

    Artificial disc replacements, which serve the function of separating vertebrae to allow for proper spinal alignment, can help treat debilitating low back pain in patients who have failed other conservative methods of treatment. A Swedish surgeon, Ulf Fernström, was the pioneer of artificial disc replacement, and his contribution in the form of Fernström balls dramatically altered spinal surgery and technique by showing the proper technique and implant that should be used for areas requiring motion in many planes. Ulf Fernström created his artificial disc inspired by the movement of the hip and knee joints. His implants attempted to restore disc spacing and articulation in patients who had failed conservative measures of treatment. Fernström balls were the first implants of their kind and represent the first attempt at artificial disc replacement. However, many surgeons and researchers questioned Fernström balls, claiming that their lack of elastic properties could damage patients. Of the wide range of implants on the market for the intervertebral disc space, all designs and applications of products stem from the initial discovery made by Fernström, thus making him a pioneer in disc replacement. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Comparative Effectiveness of Treatments for Chronic Low Back Pain: A Multiple Treatment Comparison Analysis.

    PubMed

    Rihn, Jeffrey A; Radcliff, Kristen; Norvell, Daniel C; Eastlack, Robert; Phillips, Frank M; Berland, Daniel; Sherry, Ned; Freedman, Mitchell; Vaccaro, Alexander R

    2017-06-01

    A systematic review and network meta-analysis. To determine current treatment options of chronic low back pain (LBP) as defined by randomized controlled trials (RCTs) and to compare effectiveness of those treatments using a mixed-treatment comparison (MTC). It is important to provide an evidence-based assessment of the treatment options that exist for LBP. A systematic search of RCTs was conducted in MEDLINE and the Cochrane Collaboration Library from 1990 to 2014. From the selected studies, we extracted preoperative and postoperative ODI and VAS back pain scores, additional surgeries, and complications. Standard and network meta-analytic techniques were used. Twelve RCTs were included in the analysis: 5 total disk replacement (TDR) versus fusion; 1 TDR versus exercise and cognitive behavioral therapy (CBT); 5 fusion versus exercise and CBT; and 1 fusion versus physical therapy (PT). On the basis of MTC, with respect to ODI change scores, the pooled mean difference favoring fusion over exercise and CBT was 2.0 points (95% CI, -1.2 to 4.8). The pooled mean difference favoring TDR over exercise and CBT was 6.4 points (95% CI, 3.2-9.3). The pooled mean difference favoring fusion over PT was 8.8 points (95% CI, 4.1-13.6). The pooled mean differences favoring TDR over fusion was 4.4 points (95% CI, 2.37-6.63). For PT versus structured exercise with CBT, the pooled mean difference favoring exercise with CBT over PT was 6.8 points (95% CI, 1.5-12.8). For TDR versus PT, the pooled mean difference favoring TDR over PT was 13.2 points (95% CI, 8.0-18.4). Additional surgery rates were similar between treatment options. All 4 treatments provided some benefit to patients with chronic LBP. According to the MTC analysis, TDR may be the most effective treatment and PT the least effective treatment for chronic LBP. This review is based on a limited number of RCT studies and does not support any 1 treatment modality for all patients.

  20. Translation of an engineered nanofibrous disc-like angle-ply structure for intervertebral disc replacement in a small animal model.

    PubMed

    Martin, John T; Milby, Andrew H; Chiaro, Joseph A; Kim, Dong Hwa; Hebela, Nader M; Smith, Lachlan J; Elliott, Dawn M; Mauck, Robert L

    2014-06-01

    Intervertebral disc degeneration has been implicated in the etiology of low back pain; however, the current surgical strategies for treating symptomatic disc disease are limited. A variety of materials have been developed to replace disc components, including the nucleus pulposus (NP), the annulus fibrosus (AF) and their combination into disc-like engineered constructs. We have previously shown that layers of electrospun poly(ε-caprolactone) scaffold, mimicking the hierarchical organization of the native AF, can achieve functional parity with native tissue. Likewise, we have combined these structures with cell-seeded hydrogels (as an NP replacement) to form disc-like angle-ply structures (DAPS). The objective of this study was to develop a model for the evaluation of DAPS in vivo. Through a series of studies, we developed a surgical approach to replace the rat caudal disc with an acellular DAPS and then stabilized the motion segment via external fixation. We then optimized cell infiltration into DAPS by including sacrificial poly(ethylene oxide) layers interspersed throughout the angle-ply structure. Our findings illustrate that DAPS are stable in the caudal spine, are infiltrated by cells from the peri-implant space and that infiltration is expedited by providing additional routes for cell migration. These findings establish a new in vivo platform in which to evaluate and optimize the design of functional disc replacements. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  1. Cervical facet force analysis after disc replacement versus fusion.

    PubMed

    Patel, Vikas V; Wuthrich, Zachary R; McGilvray, Kirk C; Lafleur, Matthew C; Lindley, Emily M; Sun, Derrick; Puttlitz, Christian M

    2017-05-01

    Cervical total disc replacement was developed to preserve motion and reduce adjacent-level degeneration relative to fusion, yet concerns remain that total disc replacement will lead to altered facet joint loading and long-term facet joint arthrosis. This study is intended to evaluate changes in facet contact force, pressure and surface area at the treated and superior adjacent levels before and after discectomy, disc replacement, and fusion. Ten fresh-frozen human cadaveric cervical spines were potted from C2 to C7 with pressure sensors placed into the facet joints of C3-C4 and C4-C5 via slits in the facet capsules. Moments were applied to the specimens to produce axial rotation, lateral bending and extension. Facet contact force and pressure were measured at both levels for intact, discectomy at C4-C5, disc replacement with ProDisc-C (Synthes Spine, West Chester, Pennsylvania, USA) at C4-C5, and anterior discectomy and fusion with Cervical Spine Locking Plate (Synthes Spine, West Chester, Pennsylvania, USA) at C4-C5. Facet contact area was calculated from the force and pressure measurements. An analysis of variance was used to determine significant differences with P-values <0.05 indicating significance. Facet contact force was elevated at the treated level under extension following both discectomy and disc replacement, while facet contact pressure and area were relatively unchanged. Facet contact force and area were decreased at the treated level following fusion for all three loading conditions. Total disc replacement preserved facet contact force for all scenarios except extension at the treated level, highlighting the importance of the anterior disco-ligamentous complex. This could promote treated-level facet joint disease. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis

    PubMed Central

    Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil

    2012-01-01

    Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869

  3. Southern Great Plains 1997 hydrology experiment: The spatial and temporal distribution of soil moisture within a quarter section pasture field

    NASA Technical Reports Server (NTRS)

    Tsegaye, T.; Coleman, T.; Tadesse, W.; Rajbhandari, N.; Senwo, Z.; Crosson, W.; Surrency, J.

    1998-01-01

    Understanding the spatial and temporal distribution of soil moisture near the soil surface is important to relate ground truth data to remotely sensed data using an electronically scanned thinned array radiometer (ESTAR). The research was conducted at the A-ARM EF site in the Little Washita Watershed in Chickasha Oklahoma. Soil moisture was measured on a 100 x 100-m grid on a quarter section (0.8 km by 0.8 km) size field where the DOE A-ARM SWATS is located. This site has several drainage channels and small ponds. The site is under four different land use practices, namely active pastureland, non-grazed pastureland covered with thick grass, forest area covered with trees, and a single residential area. Soil moisture was measured with a Time Domain Reflectometry (TDR) Delta-T 6-cm theta-probe and gravimetric soil moisture (GSM) technique for the top 6 cm of the soil depth. A fourth order polynomial equation was fitted to each probe calibration curve. The correlation between TDR and GSM measurement technique ranges from 0.81 to 0.91. Comparison of the spatial and temporal distribution of soil moisture measured by the TDR and GSM techniques showed very strong similarities. Such TDR probes can be used successfully to replace the GSM techniques to measure soil moisture content rapidly and accurately with site specific calibration.

  4. Valve assembly having remotely replaceable bearings

    DOEpatents

    Johnson, Evan R.; Tanner, David E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings.

  5. Total disc replacement for chronic back pain in the presence of disc degeneration.

    PubMed

    Jacobs, Wilco; Van der Gaag, Niels A; Tuschel, Alexander; de Kleuver, Marinus; Peul, Wilco; Verbout, A J; Oner, F Cumhur

    2012-09-12

    In the search for better surgical treatment of chronic low-back pain (LBP) in the presence of disc degeneration, total disc replacement has received increasing attention in recent years. A possible advantage of total disc replacement compared with fusion is maintained mobility at the operated level, which has been suggested to reduce the chance of adjacent segment degeneration. The aim of this systematic review was to assess the effect of total disc replacement for chronic low-back pain in the presence of lumbar disc degeneration compared with other treatment options in terms of patient-centred improvement, motion preservation and adjacent segment degeneration. A comprehensive search in Cochrane Back Review Group (CBRG) trials register, CENTRAL, MEDLINE, EMBASE, BIOSIS, ISI, and the FDA register was conducted. We also checked the reference lists and performed citation tracking of included studies. We included randomised controlled trials (RCTs) comparing total disc replacement with any other intervention for degenerative disc disease. We assessed risk of bias per study using the criteria of the CBRG. Quality of evidence was graded according to the GRADE approach. Two review authors independently selected studies and assessed risk of bias of the studies. Results and upper bounds of confidence intervals were compared against predefined clinically relevant differences. We included 40 publications, describing seven unique RCT's. The follow-up of the studies was 24 months, with only one extended to five years. Five studies had a low risk of bias, although there is a risk of bias in the included studies due to sponsoring and absence of any kind of blinding. One study compared disc replacement against rehabilitation and found a statistically significant advantage in favour of surgery, which, however, did not reach the predefined threshold for clinical relevance. Six studies compared disc replacement against fusion and found that the mean improvement in VAS back pain was 5.2 mm (of 100 mm) higher (two studies, 676 patients; 95% confidence interval (CI) 0.18 to 10.26) with a low quality of evidence while from the same studies leg pain showed no difference. The improvement of Oswestry score at 24 months in the disc replacement group was 4.27 points more than in the fusion group (five studies; 1207 patients; 95% CI 1.85 to 6.68) with a low quality of evidence. Both upper bounds of the confidence intervals for VAS back pain and Oswestry score were below the predefined clinically relevant difference. Choice of control group (circumferential or anterior fusion) did not appear to result in different outcomes. Although statistically significant, the differences between disc replacement and conventional fusion surgery for degenerative disc disease were not beyond the generally accepted clinical important differences with respect to short-term pain relief, disability and Quality of Life. Moreover, these analyses only represent a highly selected population. The primary goal of prevention of adjacent level disease and facet joint degeneration by using total disc replacement, as noted by the manufacturers and distributors, was not properly assessed and not a research question at all. Unfortunately, evidence from observational studies could not be used because of the high risk of bias, while these could have improved external validity assessment of complications in less selected patient groups. Non-randomised studies should however be very clear about patient selection and should incorporate independent, blinded outcome assessment, which was not the case in the excluded studies. Therefore, because we believe that harm and complications may occur after years, we believe that the spine surgery community should be prudent about adopting this technology on a large scale, despite the fact that total disc replacement seems to be effective in treating low-back pain in selected patients, and in the short term is at least equivalent to fusion surgery.

  6. An evaluation of information on the Internet of a new device: the lumbar artificial disc replacement.

    PubMed

    Garcia, Ryan M; Messerschmitt, Patrick J; Ahn, Nicholas U

    2009-02-01

    An analysis of websites, accessible to the public, was conducted pertaining to the lumbar artificial disc replacement. The objective was to investigate the content of information available on the Internet pertaining to the lumbar artificial disc replacement. The Internet is widely used by patients as an educational tool for health care information. Additionally, the Internet is used as a medium for direct-to-consumer marketing. Recent approval of the lumbar artificial disc replacement has led to the emergence of numerous websites offering information about this procedure. It is thought that patients can be influenced by information found on the Internet; therefore, it is imperative that this information be accurate and as complete as possible. Three commonly used search engines were used to locate 105 (35/search engine) websites providing information about the lumbar artificial disc replacement. Each website was evaluated with regard to authorship and content. Fifty-nine percent of the websites reviewed were authorized by a private physician group, 9% by an academic physician group, 6% by industry, 11% were news reports, and 15% were not otherwise categorized. Seventy-two percent offered a mechanism for direct contact and 30% provided clear patient selection criteria. Benefits were expressed in 87% of websites, whereas associated risks were described in 28% or less. European experiences were noted in 53%, whereas only 22% of websites detailed the current US experience. The results of this study demonstrate that much of the content of Internet-derived information pertaining to the lumbar artificial disc replacement is potentially misleading. Until long-term data are available, patients should be cautioned when using the Internet as a source for health care information, particularly with regard to the lumbar artificial disc replacement.

  7. Transforaminal Endoscopic Decompression for Foot Drop Twelve Years After Lumbar Total Disc Replacment: Technical Note.

    PubMed

    Telfeian, Albert E; Oyelese, Adetokunbo; Fridley, Jared; Gokaslan, Ziya L

    2018-05-19

    Lumbar total disc replacement (LTDR) is considered for the treatment of lumbar degenerative disc disease with the hope that by preserving motion the long-term fusion complication of adjacent segment disease can be avoided. The complications of LTDR can be divided into approach-related and long-term complications. Very little has been described about the complications and treatment for complications more than 10 years after the device has been implanted. Here we describe a tranforaminal endoscopic discectomy procedure for a patient presenting with foot drop twelve years after a L5-S1 total disc replacement. Copyright © 2018. Published by Elsevier Inc.

  8. Biomechanical comparison of a two-level Maverick disc replacement with a hybrid one-level disc replacement and one-level anterior lumbar interbody fusion.

    PubMed

    Erkan, Serkan; Rivera, Yamil; Wu, Chunhui; Mehbod, Amir A; Transfeldt, Ensor E

    2009-10-01

    Multilevel lumbar disc disease (MLDD) is a common finding in many patients. Surgical solutions for MLDD include fusion or disc replacement. The hybrid model, combining fusion and disc replacement, is a potential alternative for patients who require surgical intervention at both L5-S1 and L4-L5. The indications for this hybrid model could be posterior element insufficiency, severe facet pathology, calcified ligamentum flavum, and subarticular disease confirming spinal stenosis at L5-S1 level, or previous fusion surgery at L5-S1 and new symptomatic pathology at L4-L5. Biomechanical data of the hybrid model with the Maverick disc and anterior fusion are not available in the literature. To compare the biomechanical properties of a two-level Maverick disc replacement at L4-L5, L5-S1, and a hybrid model consisting of an L4-L5 Maverick disc replacement with an L5-S1 anterior lumbar interbody fusion using multidirectional flexibility test. An in vitro human cadaveric biomechanical study. Six fresh human cadaveric lumbar specimens (L4-S1) were subjected to unconstrained load in axial torsion (AT), lateral bending (LB), flexion (F), extension (E), and flexion-extension (FE) using multidirectional flexibility test. Four surgical treatments-intact, one-level Maverick at L5-S1, two-level Maverick between L4 and S1, and the hybrid model (anterior fusion at L5-S1 and Maverick at L4-L5) were tested in sequential order. The range of motion of each treatment was calculated. The Maverick disc replacement slightly reduced intact motion in AT and LB at both levels. The total FE motion was similar to the intact motion. However, the E motion is significantly increased (approximately 50% higher) and F motion is significantly decreased (30%-50% lower). The anterior fusion using a cage and anterior plate significantly reduced spinal motion compared with the condition (p<.05). No significant differences were found between two-level Maverick disc prosthesis and the hybrid model in terms of all motion types at L4-L5 level (p>.05). The Maverick disc preserved total motion but altered the motion pattern of the intact condition. This result is similar to unconstrained devices such as Charité. The motion at L4-L5 of the hybrid model is similar to that of two-level Maverick disc replacement. The fusion procedure using an anterior plate significantly reduced intact motion. Clinical studies are recommended to validate the efficacy of the hybrid model.

  9. ProDisc-L total disc replacement: a comparison of 1-level versus 2-level arthroplasty patients with a minimum 2-year follow-up.

    PubMed

    Hannibal, Matthew; Thomas, Derek J; Low, Jeffrey; Hsu, Ken Y; Zucherman, James

    2007-10-01

    This is a retrospective analysis of data that was collected prospectively from 2 concurrent FDA IDE lumbar arthroplasty clinical trials performed at a single center. To determine if there is a clinical difference between the 1-level ProDisc patients versus the 2-level ProDisc patients at a minimum of 2 years of follow-up. Marnay's work with ProDisc I prompted the U.S. Clinical Trials of the ProDisc II under the direction of the FDA. Disc replacement surgery in the United States has shown promising results for all types of prostheses up to 6 months. Marnay and colleagues showed that their results at 10 years were still promising, and they saw no significant difference between 1-level and multilevel disc replacements. The findings of Ipsen and colleagues suggest that multilevel arthroplasty cases may be less successful than disc replacement at a single level. Patients were part of the FDA clinical trial for the Prodisc II versus circumferential fusion study at a single institution. We identified 27 patients who received ProDisc at 1 level and 32 who received it at 2 levels with at least a 2-year follow-up, for a total of 59 patients. Unpaired t tests were performed on the mean results of Visual Analog Scale, Oswestry Disability Index, SF-36 Healthy Survey Physical Component Summary, and satisfaction using 10-cm line visual scale scores to determine a clinical difference if any between the 2 populations. While patients receiving ProDisc at 2 levels scored marginally lower in all evaluation indexes, score differences in each category were also found to hold no statistical significance. This study was unable to identify a statistically significant difference in outcome between 1- and 2-level ProDisc arthroplasty patients in a cohort from a single center. The equality of clinical effectiveness between 1- and 2-level ProDisc has yet to be determined.

  10. Focal hypermobility observed in cervical arthroplasty with Mobi-C.

    PubMed

    Kerferd, Jack William; Abi-Hanna, David; Phan, Kevin; Rao, Prashanth; Mobbs, Ralph J

    2017-12-01

    In recent decades cervical arthroplasty, or cervical disc replacement, has been steadily increasing in popularity as a procedure for the treatment of degenerative pathologies of the cervical spine. This is based on an evolving body of literature that documents superior outcomes in cervical disc replacement over fusion, for both single and double level pathologies, in well selected patients. One of the more recent and popular implants currently on the market is the Mobi-C cervical artificial disc (LDR Medical; Troyes, France). In this paper we report on two cases where focal hypermobility was observed following total disc replacement using the Mobi-C cervical artificial disc. This is followed by a discussion as to potential contributing factors to this hypermobility in relation to both implant design, and operative technique, suggesting potential changes that might prevent this in future patients.

  11. Stabilization with the Dynamic Cervical Implant: a novel treatment approach following cervical discectomy and decompression.

    PubMed

    Matgé, Guy; Berthold, Christophe; Gunness, Vimal Raj Nitish; Hana, Ardian; Hertel, Frank

    2015-03-01

    Although cervical total disc replacement (TDR) has shown equivalence or superiority to anterior cervical discectomy and fusion (ACDF), potential problems include nonphysiological motion (hypermobility), accelerated degeneration of the facet joints, particulate wear, and compromise of the mechanical integrity of the endplate during device fixation. Dynamic cervical stabilization is a novel motion-preserving concept that facilitates controlled, limited flexion and extension, but prevents axial rotation and lateral bending, thereby reducing motion across the facet joints. Shock absorption of the Dynamic Cervical Implant (DCI) device is intended to protect adjacent levels from accelerated degeneration. The authors conducted a prospective evaluation of 53 consecutive patients who underwent DCI stabilization for the treatment of 1-level (n = 42), 2-level (n = 9), and 3-level (n = 2) cervical disc disease with radiculopathy or myelopathy. Forty-seven patients (89%) completed all clinical and radiographic outcomes at a minimum of 24 months. Clinical outcomes consisted of Neck Disability Index (NDI) and visual analog scale (VAS) scores, neurological function at baseline and at latest follow-up, as well as patient satisfaction. Flexion-extension radiography was evaluated for device motion, implant migration, subsidence, and heterotopic ossification. Cervical sagittal alignment (Cobb angle), functional spinal unit (FSU) angle, and range of motion (ROM) at index and adjacent levels were evaluated with WEB 1000 software. The NDI score, VAS neck and arm pain scores, and neurological deficits were significantly reduced at each postoperative time point compared with baseline (p < 0.0001). At 24 months postoperatively, 91% of patients were very satisfied and 9% somewhat satisfied, while 89% would definitely and 11% would probably elect to have the same surgery again. In 47 patients with 58 operated levels, the radiographic assessment showed good motion (5°-12°) of the device in 57%, reduced motion (2°-5°) in 34.5%, and little motion (0-2°) in 8.5%. The Cobb and FSU angles improved, showing a clear tendency for lordosis with the DCI. Motion greater than 2° of the treated segment could be preserved in 91.5%, while 8.5% had a near segmental fusion. Mean ROM at index levels demonstrated satisfying motion preservation with DCI. Mean ROM at upper and lower adjacent levels showed maintenance of adjacent-level kinematics. Heterotopic ossification, including 20% minor and 15% major, had no direct impact on clinical results. There were 2 endplate subsidences detected with an increased segmental lordosis. One asymptomatic anterior device migration required reoperation. Three patients underwent a secondary surgery in another segment during follow-up, twice for a new disc herniation and once for an adjacent degeneration. There was no posterior migration and no device breakage. Preliminary results indicate that the DCI implanted using a proper surgical technique is safe and facilitates excellent clinical outcomes, maintains index-and adjacent-level ROM in the majority of cases, improves sagittal alignment, and may be suitable for patients with facet arthrosis who would otherwise not be candidates for cervical TDR. Shock absorption together with maintained motion in the DCI may protect adjacent levels from early degeneration in longer follow-up.

  12. In Vitro Maturation and In Vivo Integration and Function of an Engineered Cell-Seeded Disc-like Angle Ply Structure (DAPS) for Total Disc Arthroplasty.

    PubMed

    Martin, J T; Gullbrand, S E; Kim, D H; Ikuta, K; Pfeifer, C G; Ashinsky, B G; Smith, L J; Elliott, D M; Smith, H E; Mauck, R L

    2017-11-17

    Total disc replacement with an engineered substitute is a promising avenue for treating advanced intervertebral disc disease. Toward this goal, we developed cell-seeded disc-like angle ply structures (DAPS) and showed through in vitro studies that these constructs mature to match native disc composition, structure, and function with long-term culture. We then evaluated DAPS performance in an in vivo rat model of total disc replacement; over 5 weeks in vivo, DAPS maintained their structure, prevented intervertebral bony fusion, and matched native disc mechanical function at physiologic loads in situ. However, DAPS rapidly lost proteoglycan post-implantation and did not integrate into adjacent vertebrae. To address this, we modified the design to include polymer endplates to interface the DAPS with adjacent vertebrae, and showed that this modification mitigated in vivo proteoglycan loss while maintaining mechanical function and promoting integration. Together, these data demonstrate that cell-seeded engineered discs can replicate many characteristics of the native disc and are a viable option for total disc arthroplasty.

  13. Effect of feed delivery method on the behavior and growth of dairy heifers.

    PubMed

    Greter, A M; Leslie, K E; Mason, G J; McBride, B W; Devries, T J

    2010-04-01

    The objective of this study was to determine the effects of feed delivery method on growth, feeding competition, feeding, and sorting behavior of dairy heifers. Thirty-two Holstein heifers (146.2+/-21.9 d of age) were divided into 8 groups of 4 and exposed to 1 of 2 feed delivery treatments for 13 wk. The treatment rations contained 65% grass/alfalfa haylage and 35% textured concentrate (on a dry matter basis) fed as a 1) total mixed ration (TMR) or 2) top-dressed ration (TDR). Group dry matter intakes were recorded daily throughout the experiment. Feeding behavior, recorded using time-lapse video, and sorting behavior were measured for 7 d during each of wk 1, 5, 9, and 13. Sorting activity was determined through particle size analysis of the fresh feed and orts. The particle size separator separated feed into 4 fractions (long, medium, short, and fine). Sorting of each fraction was calculated as actual intake expressed as a percentage of predicted intake. Heifers were fecal scored for consistency of stool twice weekly using a scale from 1 (liquid) to 4 (solid); heifers were weighed every 2 wk. Neither dry matter intake (7.3 kg/d) nor average daily gain (1.3 kg/d) differed between treatments. Heifers fed the TDR tended to consume less neutral detergent fiber than heifers fed the TMR (4.77 vs. 4.91 kg/d). Heifers fed the TDR sorted against long particles (98.9 vs. 96.0%) and consumed short particles (100.3 vs. 101.1%) to a greater extent than did heifers fed the TMR. Daily feeding time did not differ between treatments (201.0 min/d), but heifers on the TDR did spend more time at the bunk in the 2h following feed delivery (50.1 vs. 32.0 min/d). Heifers fed the TDR were displaced from the feed bunk more frequently than heifers fed the TMR (17.6 vs. 8.6 times/d), particularly during the 2-h period following feed delivery. Fecal scores were lower for heifers on the TDR (2.7 vs. 3.4). These results suggest that feeding a TMR to replacement dairy heifers may promote a more even diurnal feeding pattern, minimize feed sorting and feed bunk competition, and promote more solid fecal consistency. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. National Prevalence and Trends of HIV Transmitted Drug Resistance in Mexico

    PubMed Central

    Avila-Ríos, Santiago; García-Morales, Claudia; Garrido-Rodríguez, Daniela; Ormsby, Christopher E.; Hernández-Juan, Ramón; Andrade-Villanueva, Jaime; González-Hernández, Luz A.; Torres-Escobar, Indiana; Navarro-Álvarez, Samuel; Reyes-Terán, Gustavo

    2011-01-01

    Background Transmitted drug resistance (TDR) remains an important concern for the management of HIV infection, especially in countries that have recently scaled-up antiretroviral treatment (ART) access. Methodology/Principal Findings We designed a study to assess HIV diversity and transmitted drug resistance (TDR) prevalence and trends in Mexico. 1655 ART-naïve patients from 12 Mexican states were enrolled from 2005 to 2010. TDR was assessed from plasma HIV pol sequences using Stanford scores and the WHO TDR surveillance mutation list. TDR prevalence fluctuations over back-projected dates of infection were tested. HIV subtype B was highly prevalent in Mexico (99.9%). TDR prevalence (Stanford score>15) in the country for the study period was 7.4% (95% CI, 6.2∶8.8) and 6.8% (95% CI, 5.7∶8.2) based on the WHO TDR surveillance mutation list. NRTI TDR was the highest (4.2%), followed by NNRTI (2.5%) and PI (1.7%) TDR. Increasing trends for NNRTI (p = 0.0456) and PI (p = 0.0061) major TDR mutations were observed at the national level. Clustering of viruses containing minor TDR mutations was observed with some apparent transmission pairs and geographical effects. Conclusions TDR prevalence in Mexico remains at the intermediate level and is slightly lower than that observed in industrialized countries. Whether regional variations in TDR trends are associated with differences in antiretroviral drug usage/ART efficacy or with local features of viral evolution remains to be further addressed. PMID:22110765

  15. A solid state video recorder as a direct replacement of a mechanically driven disc recording device in a security system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terry, P.L.

    1989-01-01

    Whether upgrading or developing a security system, investing in a solid state video recorder may prove to be quite prudent. Even though the initial cost of a solid state recorder may be more expensive, when comparing it to a disc recorder it is practically maintenance free. Thus, the cost effectiveness of a solid state video recorder over an extended period of time more than justifies the initial expense. This document illustrates the use of a solid state video recorder as a direct replacement. It replaces a mechanically driven disc recorder that existed in a synchronized video recording system. The originalmore » system was called the Universal Video Disc Recorder System. The modified system will now be referred to as the Solid State Video Recording System. 5 figs.« less

  16. Hybrids: good for cars and the environment-are they good for the spine too?

    PubMed

    Bono, Christopher M

    2009-10-01

    Erkan S, Rivera Y, Wu C, et al. Biomechanical comparison of a two-level Maverick disc replacement with a hybrid one-level disc replacement and one-level anterior lumbar interbody fusion. Spine J 2009;9:830-835 (in this issue).

  17. Evaluation of Electrospun Nanofiber-Anchored Silicone for the Degenerative Intervertebral Disc

    PubMed Central

    Riahanizad, S.

    2017-01-01

    The nucleus pulposus (NP) substitution by polymeric gel is one of the promising techniques for the repair of the degenerative intervertebral disc (IVD). Silicone gel is one of the potential candidates for a NP replacement material. Electrospun fiber anchorage to silicone disc, referred as ENAS disc, may not only improve the biomechanical performances of the gel but it can also improve restoration capability of the gel, which is unknown. This study successfully produced a novel process to anchor any size and shape of NP gel with electrospun fiber mesh. Viscoelastic properties of silicone and ENAS disc were measured using standard experimental techniques and compared with the native tissue properties. Ex vivo mechanical tests were conducted on ENAS disc-implanted rabbit tails to the compare the mechanical stability between intact and ENAS implanted spines. This study found that viscoelastic properties of ENAS disc are higher than silicone disc and comparable to the viscoelastic properties of human NP. The ex vivo studies found that the ENAS disc restore the mechanical functionality of rabbit tail spine, after discectomy of native NP and replacing the NP by ENAS disc. Therefore, the PCL ENF mesh anchoring technique to a NP implant can have clinical potential. PMID:29181144

  18. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... permanent dark ink or its equivalent; and (v) Presented in a form having sufficient clarity and contrast... statement that the replacement compact disc contains no new matter. The compact disc and copy must be...

  19. Design and evaluation of a high sensitivity spiral TDR scour sensor

    NASA Astrophysics Data System (ADS)

    Gao, Quan; (Bill Yu, Xiong

    2015-08-01

    Bridge scour accounts for more than half of the reported bridge failures in the United States. Scour monitoring technology based on time domain reflectometry (TDR) features the advantages of being automatic and inexpensive. The senior author’s team has developed a few generations of a TDR bridge scour monitoring system, which have succeeded in both laboratory and field evaluations. In this study, an innovative spiral TDR sensor is proposed to further improve the sensitivity of the TDR sensor in scour detection. The spiral TDR sensor is made of a parallel copper wire waveguide wrapped around a mounting rod. By using a spiral path for the waveguide, the TDR sensor achieves higher sensitivity than the traditional straight TDR probes due to longer travel distance of the electromagnetic (EM) wave per unit length in the spiral probe versus traditional probe. The performance of the new TDR spiral scour sensor is validated by calibration with liquids with known dielectric constant and wet soils. Laboratory simulated scour-refilling experiments are performed to evaluate the performance of the new spiral probe in detecting the sediment-water interface and therefore the scour-refill process. The tests results indicate that scour depth variation of less than 2 cm can be easily detected by this new spiral sensor. A theory is developed based on the dielectric mixing model to simplify the TDR signal analyses for scour depth detection. The sediment layer thickness (directly related to scour depth) varies linearly with the square root of the bulk dielectric constant of the water-sediment mixture measured by the spiral TDR probe, which matches the results of theoretical prediction. The estimated sediment layer thickness and therefore scour depth from the spiral TDR sensor agrees very well with that by direct physical measurement. The spiral TDR sensor is four times more sensitive than a traditional straight TDR probe.

  20. Primary Drug Resistance in South Africa: Data from 10 Years of Surveys

    PubMed Central

    Manasa, Justen; Katzenstein, David; Cassol, Sharon; Newell, Marie-Louise

    2012-01-01

    Abstract HIV-1 transmitted drug resistance (TDR) could reverse the gains of antiretroviral rollout. To ensure that current first-line therapies remain effective, TDR levels in recently infected treatment-naive patients need to be monitored. A literature review and data mining exercise was carried out to determine the temporal trends in TDR in South Africa. In addition, 72 sequences from seroconvertors identified from Africa Centre's 2010 HIV surveillance round were also examined for TDR. Publicly available data on TDR were retrieved from GenBank, curated in RegaDB, and analyzed using the Calibrated Population Resistance Program. There was no evidence of TDR from the 2010 rural KwaZulu Natal samples. Ten datasets with a total of 1618 sequences collected between 2000 and 2010 were pooled to provide a temporal analysis of TDR. The year with the highest TDR rate was 2002 [6.67%, 95% confidence interval (CI): 3.09–13.79%; n=6/90]. After 2002, TDR levels returned to <5% (WHO low-level threshold) and showed no statistically significant increase in the interval between 2002 and 2010. The most common mutations were associated with NNRTI resistance, K103N, followed by Y181C and Y188C/L. Five sequences had multiple resistance mutations associated with NNRTI resistance. There is no evidence of TDR in rural KwaZulu-Natal. TDR levels in South Africa have remained low following a downward trend since 2003. Continuous vigilance in monitoring of TDR is needed as more patients are initiated and maintained onto antiretroviral therapy. PMID:22251009

  1. An evaluation of information on the internet about a new device: the cervical artificial disc replacement.

    PubMed

    Qureshi, Sheeraz A; Koehler, Steven M; Lin, James D; Bird, Justin; Garcia, Ryan M; Hecht, Andrew C

    2012-05-01

    Cross-sectional survey. The objective of this study was to investigate the authorship, content, and quality of information available to the public on the Internet pertaining to the cervical artificial disc replacement device. The Internet is widely used by patients as an educational tool for health care information. In addition, the Internet is used as a medium for direct-to-consumer marketing. Increasing interest in cervical artificial disc replacement has led to the emergence of numerous Web sites offering information about this procedure. It is thought that patients can be influenced by information found on the Internet. A cross section of Web sites accessible to the general public was surveyed. Three commonly used search engines were used to locate 150 (50/search engine) Web sites providing information about the cervical artificial disc replacement. Each Web site was evaluated with regard to authorship and content. Fifty-three percent of the Web sites reviewed were authorized by a private physician group, 4% by an academic physician group, 13% by industry, 16% were news reports, and 14% were not otherwise categorized. Sixty-five percent of Web sites offered a mechanism for direct contact and 19% provided clear patient eligibility criteria. Benefits were expressed in 80% of Web sites, whereas associated risks were described in 35% or less. European experiences were noted in 17% of Web sites, whereas only 9% of Web sites detailed the current US experience. CONCLUSION.: The results of this study demonstrate that much of the content of the Internet-derived information pertaining to the cervical artificial disc replacement is for marketing purposes and may not represent unbiased information. Until we can confirm the content on a Web site to be accurate, patients should be cautioned when using the Internet as a source for health care information related to cervical disc replacement.

  2. 37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... by a typewriter or machine printer in permanent dark ink or its equivalent; and (v) Presented in a... accompanied by a statement that the replacement compact disc contains no new matter. The compact disc and copy...

  3. Prevalence and patterns of HIV transmitted drug resistance in Guatemala.

    PubMed

    Avila-Ríos, Santiago; Mejía-Villatoro, Carlos R; García-Morales, Claudia; Soto-Nava, Maribel; Escobar, Ingrid; Mendizabal, Ricardo; Girón, Amalia; García, Leticia; Reyes-Terán, Gustavo

    2011-12-01

    To assess human immunodeficiency virus (HIV) diversity and the prevalence of transmitted drug resistance (TDR) in Guatemala. One hundred forty-five antiretroviral treatment-naïve patients referred to the Roosevelt Hospital in Guatemala City were enrolled from October 2010 to March 2011. Plasma HIV pol sequences were obtained and TDR was assessed with the Stanford algorithm and the World Health Organization (WHO) TDR surveillance mutation list. HIV subtype B was highly prevalent in Guatemala (96.6%, 140/145), and a 2.8% (4/145) prevalence of BF1 recombinants and 0.7% (1/145) prevalence of subtype C viruses were found. TDR prevalence for the study period was 8.3% (12/145) with the Stanford database algorithm (score > 15) and the WHO TDR surveillance mutation list. Most TDR cases were associated with non-nucleoside reverse transcriptase inhibitors (NNRTIs) (83.3%, 10/12); a low prevalence of nucleoside reverse transcriptase inhibitors and protease inhibitors was observed in the cohort (< 1% for both families). Low selection of antiretroviral drug resistance mutations was found, except for NNRTI-associated mutations. Major NNRTI mutations such as K101E, K103N, and E138K showed higher frequencies than expected in ART-naïve populations. Higher literacy was associated with a greater risk of TDR (odds ratio 4.14, P = 0.0264). This study represents one of the first efforts to describe HIV diversity and TDR prevalence and trends in Guatemala. TDR prevalence in Guatemala was at the intermediate level. Most TDR cases were associated with NNRTIs. Further and continuous TDR surveillance is necessary to gain more indepth knowledge about TDR spread and trends in Guatemala and to optimize treatment outcomes in the country.

  4. Assessing the accuracy of TDR-based water leak detection system

    NASA Astrophysics Data System (ADS)

    Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.

    2018-03-01

    The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.

  5. Surveillance of transmitted HIV drug resistance in antiretroviral-naive patients aged less than 25 years, in Bangkok, Thailand.

    PubMed

    Sungkanuparph, Somnuek; Pasomsub, Ekawat; Chantratita, Wasun

    2014-01-01

    Emergence of transmitted HIV drug resistance (TDR) is a concern after global scale-up of antiretroviral therapy (ART). World Health Organization had developed threshold survey method for surveillance of TDR in resource-limited countries. ART in Thailand has been scaling up for >10 years. To evaluate the current TDR in Thailand, a cross-sectional study was conducted among antiretroviral-naive HIV-infected patients aged <25 years who newly visited infectious disease clinic in a university hospital, in 2011. HIV genotypic-resistance test was performed. World Health Organization 2009 surveillance drug-resistance mutations were used to define TDR. Of 50 patients, the prevalence of TDR was 4%. Of 2 patients with TDR, 1 had K103N and the other had Y181C mutations. Transmitted HIV drug resistance is emerging in Thailand after a decade of rapid scale-up of ART. Interventions to prevent TDR at the population level are essentially needed in Thailand. Surveillance for TDR in Thailand has to be regularly performed.

  6. Feed delivery method affects the learning of feeding and competitive behavior in dairy heifers.

    PubMed

    Greter, A M; Leslie, K E; Mason, G J; McBride, B W; DeVries, T J

    2010-08-01

    The objective of this study was to determine how different feeding methods may affect the learning of feeding, sorting, and competitive behavior of growing dairy heifers. We hypothesized that heifers previously fed a total mixed ration (TMR) would distribute their feeding time more evenly throughout the day, sort the new ration less, compete less for feed, maintain a more solid fecal consistency, and continue to grow rapidly compared with heifers previously fed a top-dressed ration (TDR). Thirty-two Holstein heifers (237.2+/-21.9 d of age) were divided into 8 groups of 4 and exposed to 1 of 2 treatments for 13 wk: 1) TMR or 2) TDR, with each containing 65% grass/alfalfa haylage and 35% textured concentrate on a dry matter (DM) basis. Following this feeding period, all heifers were switched to an unfamiliar TMR containing 56.1% grass/alfalfa haylage, 21.0% corn silage, 21.0% high-moisture corn, and 1.9% mineral supplement (DM basis) for 7 wk. Group DM intakes were recorded daily throughout the experiment. Feeding behavior, recorded using time-lapse video, and sorting behavior were measured for 7 d during wk 1, 4, and 7 after the dietary change. Feeding competition was measured on d 2, 4, and 6 of each recording week. Sorting activity was determined through particle size analysis of the fresh feed and orts. The particle size separator separated feed into 4 fractions (long, medium, short, and fine). Sorting of each fraction was calculated as actual intake expressed as a percentage of predicted intake. Animals were scored for fecal consistency twice weekly, using a scale from 1 (liquid) to 4 (solid). Heifers were weighed every 2 wk. Neither DM intake (9.0 kg/d) nor average daily gain (1.2 kg/d) differed between treatments. Sorting also did not differ between treatments. Heifers tended to spend more time feeding if they had previously been fed a TDR (198.8 vs. 186.8 min/d). As they had done before the dietary change, heifers previously fed the TDR spent more time at the bunk in the 2h following feed delivery (40.6 vs. 25.9 min/d). Heifers previously fed the TDR were displaced from the feed bunk more frequently than heifers previously fed the TMR (23.0 vs. 13.1 times/d), particularly during the 2-h period following feed delivery. Fecal scores were lower (more fluid in consistency) for heifers originally fed the TDR (3.2 vs. 3.7). The continued difference in feed bunk competition suggests that heifers previously fed the TDR had learned these patterns in the past, retaining them even when switched to an unfamiliar ration. Furthermore, lower fecal scores for heifers previously fed the TDR suggest altered rumen fermentation, possibly because of altered diurnal consumption patterns. These results show that feeding a TMR to replacement dairy heifers from a young age promotes a more even diurnal feeding pattern, minimizes feed bunk competition, and promotes a more solid fecal consistency. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    PubMed

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  8. 78 FR 24426 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-25

    ... application for the Kineflex/C Cervical Artificial Disc sponsored by SpinalMotion. The Kineflex/C is a metal-on-metal (cobalt chrome molybdenum alloy) cervical total disc replacement device. The Kineflex/C is... degenerative disc disease (DDD) where DDD is defined as discogenic back pain with degeneration of the disc as...

  9. MECHANICAL DESIGN CRITERIA FOR INTERVERTEBRAL DISC TISSUE ENGINEERING

    PubMed Central

    Nerurkar, Nandan L.; Elliott, Dawn M.; Mauck, Robert L.

    2009-01-01

    Due to the inability of current clinical practices to restore function to degenerated intervertebral discs, the arena of disc tissue engineering has received substantial attention in recent years. Despite tremendous growth and progress in this field, translation to clinical implementation has been hindered by a lack of well-defined functional benchmarks. Because successful replacement of the disc is contingent upon replication of some or all of its complex mechanical behaviour, it is critically important that disc mechanics be well characterized in order to establish discrete functional goals for tissue engineering. In this review, the key functional signatures of the intervertebral disc are discussed and used to propose a series of native tissue benchmarks to guide the development of engineered replacement tissues. These benchmarks include measures of mechanical function under tensile, compressive and shear deformations for the disc and its substructures. In some cases, important functional measures are identified that have yet to be measured in the native tissue. Ultimately, native tissue benchmark values are compared to measurements that have been made on engineered disc tissues, identifying measures where functional equivalence was achieved, and others where there remain opportunities for advancement. Several excellent reviews exist regarding disc composition and structure, as well as recent tissue engineering strategies; therefore this review will remain focused on the functional aspects of disc tissue engineering. PMID:20080239

  10. Short, multi-needle FDR sensor suitable for measuring soil water content

    USDA-ARS?s Scientific Manuscript database

    Time domain reflectometry (TDR) is a well-established electromagnetic technique used to measure soil water content. TDR sensors have been combined with heat pulse sensors to produce thermo-TDR sensors. Thermo-TDR sensors are restricted to having relatively short needles in order to accurately measur...

  11. Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty.

    PubMed

    Gornet, Matthew F; Burkus, J K; Harper, M L; Chan, F W; Skipor, A K; Jacobs, J J

    2013-04-01

    Metal-on-metal total disc replacement is a recent alternative treatment for degenerative disc disease. Wear and corrosion of these implants can lead to local and systemic transport of metal debris. This prospective longitudinal study examined the serum chromium and cobalt levels in 24 patients with cobalt-chromium alloy metal-on-metal lumbar disc replacements. Serum was assayed for chromium (Cr) and cobalt (Co) using high-resolution inductively-coupled plasma-mass spectrometry. Detection limits were 0.015 ng/mL for Cr and 0.04 ng/mL for Co. Median serum Co levels at pre-op, 3, 6, 12, 24, and 36-months post-op were 0.10, 1.03, 0.96, 0.98, 0.67, and 0.52 ng/mL, respectively. Median serum Cr levels were 0.06, 0.49, 0.65, 0.43, 0.52, and 0.50 ng/mL, respectively. In general, these results indicated that serum Co and Cr levels are elevated at all postoperative time points and are of the same order of magnitude as those observed in well-functioning metal-on-metal surface replacements of the hip and in metal-on-metal total hip replacements at similar postoperative time points.

  12. Defining the Ideal Lumbar Total Disc Replacement Patient and Standard of Care.

    PubMed

    Gornet, Matthew; Buttermann, Glenn; Guyer, Richard; Yue, James; Ferko, Nicole; Hollmann, Sarah

    2017-12-15

    : Lumbar total disc replacement, now in use since 2004, was determined by the panel to be a standard of care for the treatment of symptomatic single-level lumbar degenerative disc disease in the active patient subpopulation as outlined by the investigational device exemption study criteria. The large body of evidence supporting this statement, including surgeons' experiences, was presented and discussed. Consensus statements focusing on decision-making criteria reflected that efficacy, long-term safety, clinical outcomes with validated measures, and cost-effectiveness should form the basis of decision-making by payers. Diagnostic challenges with lumbar degenerative disc disease patients were discussed among the panel, and it was concluded that although variably used among surgeons, reliable tools exist to appropriately diagnose discogenic back pain.

  13. Intervertebral disc regeneration or repair with biomaterials and stem cell therapy--feasible or fiction?

    PubMed

    Chan, Samantha C W; Gantenbein-Ritter, Benjamin

    2012-05-31

    The "gold standard" for treatment of intervertebral disc herniations and degenerated discs is still spinal fusion, corresponding to the saying "no disc - no pain". Mechanical prostheses, which are currently implanted, do only have medium outcome success and have relatively high re-operation rates. Here, we discuss some of the biological intervertebral disc replacement approaches, which can be subdivided into at least two classes in accordance to the two different tissue types, the nucleus pulposus (NP) and the annulus fibrosus (AF). On the side of NP replacement hydrogels have been extensively tested in vitro and in vivo. However, these gels are usually a trade-off between cell biocompatibility and load-bearing capacity, hydrogels which fulfill both are still lacking. On the side of AF repair much less is known and the question of the anchoring of implants is still to be addressed. New hope for cell therapy comes from developmental biology investigations on the existence of intervertebral disc progenitor cells, which would be an ideal cell source for cell therapy. Also notochordal cells (remnants of the embryonic notochord) have been recently pushed back into focus since these cells have regenerative potential and can activate disc cells. Growth factor treatment and molecular therapies could be less problematic. The biological solutions for NP and AF replacement are still more fiction than fact. However, tissue engineering just scratched the tip of the iceberg, more satisfying solutions are yet to be added to the biomedical pipeline.

  14. Low Prevalence of Transmitted Drug Resistance in Patients Newly Diagnosed with HIV-1 Infection in Sweden 2003–2010

    PubMed Central

    Karlsson, Annika; Björkman, Per; Bratt, Göran; Ekvall, Håkan; Gisslén, Magnus; Sönnerborg, Anders; Mild, Mattias; Albert, Jan

    2012-01-01

    Transmitted drug resistance (TDR) is a clinical and epidemiological problem because it may contribute to failure of antiretroviral treatment. The prevalence of TDR varies geographically, and its prevalence in Sweden during the last decade has not been reported. Plasma samples from 1,463 patients newly diagnosed with HIV-1 infection between 2003 and 2010, representing 44% of all patients diagnosed in Sweden during this period, were analyzed using the WHO 2009 list of mutations for surveillance of TDR. Maximum likelihood phylogenetic analyses were used to determine genetic subtype and to investigate the relatedness of the sequences. Eighty-two patients showed evidence of TDR, representing a prevalence of 5.6% (95% CI: 4.5%–6.9%) without any significant time trends or differences between patients infected in Sweden or abroad. Multivariable logistic regression showed that TDR was positively associated with men who have sex with men (MSM) and subtype B infection and negatively associated with CD4 cell counts. Among patients with TDR, 54 (68%) had single resistance mutations, whereas five patients had multi-drug resistant HIV-1. Phylogenetic analyses identified nine significantly supported clusters involving 29 of the patients with TDR, including 23 of 42 (55%) of the patients with TDR acquired in Sweden. One cluster contained 18 viruses with a M41L resistance mutation, which had spread among MSM in Stockholm over a period of at least 16 years (1994–2010). Another cluster, which contained the five multidrug resistant viruses, also involved MSM from Stockholm. The prevalence of TDR in Sweden 2003–2010 was lower than in many other European countries. TDR was concentrated among MSM, where clustering of TDR strains was observed, which highlights the need for continued and improved measures for targeted interventions. PMID:22448246

  15. Low prevalence of transmitted drug resistance in patients newly diagnosed with HIV-1 infection in Sweden 2003-2010.

    PubMed

    Karlsson, Annika; Björkman, Per; Bratt, Göran; Ekvall, Håkan; Gisslén, Magnus; Sönnerborg, Anders; Mild, Mattias; Albert, Jan

    2012-01-01

    Transmitted drug resistance (TDR) is a clinical and epidemiological problem because it may contribute to failure of antiretroviral treatment. The prevalence of TDR varies geographically, and its prevalence in Sweden during the last decade has not been reported. Plasma samples from 1,463 patients newly diagnosed with HIV-1 infection between 2003 and 2010, representing 44% of all patients diagnosed in Sweden during this period, were analyzed using the WHO 2009 list of mutations for surveillance of TDR. Maximum likelihood phylogenetic analyses were used to determine genetic subtype and to investigate the relatedness of the sequences. Eighty-two patients showed evidence of TDR, representing a prevalence of 5.6% (95% CI: 4.5%-6.9%) without any significant time trends or differences between patients infected in Sweden or abroad. Multivariable logistic regression showed that TDR was positively associated with men who have sex with men (MSM) and subtype B infection and negatively associated with CD4 cell counts. Among patients with TDR, 54 (68%) had single resistance mutations, whereas five patients had multi-drug resistant HIV-1. Phylogenetic analyses identified nine significantly supported clusters involving 29 of the patients with TDR, including 23 of 42 (55%) of the patients with TDR acquired in Sweden. One cluster contained 18 viruses with a M41L resistance mutation, which had spread among MSM in Stockholm over a period of at least 16 years (1994-2010). Another cluster, which contained the five multidrug resistant viruses, also involved MSM from Stockholm. The prevalence of TDR in Sweden 2003-2010 was lower than in many other European countries. TDR was concentrated among MSM, where clustering of TDR strains was observed, which highlights the need for continued and improved measures for targeted interventions.

  16. First Line Treatment Response in Patients with Transmitted HIV Drug Resistance and Well Defined Time Point of HIV Infection: Updated Results from the German HIV-1 Seroconverter Study

    PubMed Central

    zu Knyphausen, Fabia; Scheufele, Ramona; Kücherer, Claudia; Jansen, Klaus; Somogyi, Sybille; Dupke, Stephan; Jessen, Heiko; Schürmann, Dirk; Hamouda, Osamah; Meixenberger, Karolin; Bartmeyer, Barbara

    2014-01-01

    Background Transmission of drug-resistant HIV-1 (TDR) can impair the virologic response to antiretroviral combination therapy. Aim of the study was to assess the impact of TDR on treatment success of resistance test-guided first-line therapy in the German HIV-1 Seroconverter Cohort for patients infected with HIV between 1996 and 2010. An update of the prevalence of TDR and trend over time was performed. Methods Data of 1,667 HIV-infected individuals who seroconverted between 1996 and 2010 were analysed. The WHO drug resistance mutations list was used to identify resistance-associated HIV mutations in drug-naïve patients for epidemiological analysis. For treatment success analysis the Stanford algorithm was used to classify a subset of 323 drug-naïve genotyped patients who received a first-line cART into three resistance groups: patients without TDR, patients with TDR and fully active cART and patients with TDR and non-fully active cART. The frequency of virologic failure 5 to 12 months after treatment initiation was determined. Results Prevalence of TDR was stable at a high mean level of 11.9% (198/1,667) in the HIV-1 Seroconverter Cohort without significant trend over time. Nucleotide reverse transcriptase inhibitor resistance was predominant (6.0%) and decreased significantly over time (OR = 0.92, CI = 0.87–0.98, p = 0.01). Non-nucleoside reverse transcriptase inhibitor (2.4%; OR = 1.00, CI = 0.92–1.09, p = 0.96) and protease inhibitor resistance (2.0%; OR = 0.94, CI = 0.861.03, p = 0.17) remained stable. Virologic failure was observed in 6.5% of patients with TDR receiving fully active cART, 5,6% of patients with TDR receiving non-fully active cART and 3.2% of patients without TDR. The difference between the three groups was not significant (p = 0.41). Conclusion Overall prevalence of TDR remained stable at a rather high level. No significant differences in the frequency of virologic failure were identified during first-line cART between patients with TDR and fully-active cART, patients with TDR and non-fully active cART and patients without TDR. PMID:24788613

  17. Finite Element Analysis of Influence of Axial Position of Center of Rotation of a Cervical Total Disc Replacement on Biomechanical Parameters: Simulated 2-Level Replacement Based on a Validated Model.

    PubMed

    Li, Yang; Zhang, Zhenjun; Liao, Zhenhua; Mo, Zhongjun; Liu, Weiqiang

    2017-10-01

    Finite element models have been widely used to predict biomechanical parameters of the cervical spine. Previous studies investigated the influence of position of rotational centers of prostheses on cervical biomechanical parameters after 1-level total disc replacement. The purpose of this study was to explore the effects of axial position of rotational centers of prostheses on cervical biomechanics after 2-level total disc replacement. A validated finite element model of C3-C7 segments and 2 prostheses, including the rotational center located at the superior endplate (SE) and inferior endplate (IE), was developed. Four total disc replacement models were used: 1) IE inserted at C4-C5 disc space and IE inserted at C5-C6 disc space (IE-IE), 2) IE-SE, 3) SE-IE, and 4) SE-SE. All models were subjected to displacement control combined with a 50 N follower load to simulate flexion and extension motions in the sagittal plane. For each case, biomechanical parameters, including predicted moments, range of rotation at each level, facet joint stress, and von Mises stress on the ultra-high-molecular-weight polyethylene core of the prostheses, were calculated. The SE-IE model resulted in significantly lower stress at the cartilage level during extension and at the ultra-high-molecular-weight polyethylene cores when compared with the SE-SE construct and did not generate hypermotion at the C4-C5 level compared with the IE-SE and IE-IE constructs. Based on the present analysis, the SE-IE construct is recommended for treating cervical disease at the C4-C6 level. This study may provide a useful model to inform clinical operations. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Mechanical design criteria for intervertebral disc tissue engineering.

    PubMed

    Nerurkar, Nandan L; Elliott, Dawn M; Mauck, Robert L

    2010-04-19

    Due to the inability of current clinical practices to restore function to degenerated intervertebral discs, the arena of disc tissue engineering has received substantial attention in recent years. Despite tremendous growth and progress in this field, translation to clinical implementation has been hindered by a lack of well-defined functional benchmarks. Because successful replacement of the disc is contingent upon replication of some or all of its complex mechanical behaviors, it is critically important that disc mechanics be well characterized in order to establish discrete functional goals for tissue engineering. In this review, the key functional signatures of the intervertebral disc are discussed and used to propose a series of native tissue benchmarks to guide the development of engineered replacement tissues. These benchmarks include measures of mechanical function under tensile, compressive, and shear deformations for the disc and its substructures. In some cases, important functional measures are identified that have yet to be measured in the native tissue. Ultimately, native tissue benchmark values are compared to measurements that have been made on engineered disc tissues, identifying where functional equivalence was achieved, and where there remain opportunities for advancement. Several excellent reviews exist regarding disc composition and structure, as well as recent tissue engineering strategies; therefore this review will remain focused on the functional aspects of disc tissue engineering. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Lumbar Disc Replacement for Junctional Decompensation After Fusion Surgery: Clinical and Radiological Outcome at an Average Follow-Up of 33 Months

    PubMed Central

    Sliwa, Karen; Weinberg, Ian R.; Sweet, Barry MBE; de Villiers, Malan; Candy, Geoffrey P.

    2007-01-01

    Background Failed fusion surgery remains difficult to treat. Few published data on disc replacement surgery after failed fusion procedures exist. Our objective was to evaluate outcomes of junctional lumbar disc replacement after previous fusion surgery and to correlate outcome with radiological changes to parameters of sagittal balance. Methods Out of a single-center prospective registry of 290 patients with 404 lumbar disc replacements, 27 patients had had a previous lumbar fusion operation on 1 to 4 lumbar segments and had completed a mean follow- up of 33 months (range: 18–56). We correlated the clinical outcome measures (patient satisfaction, 10-point pain score, and Oswestry Disability Index [ODI] score) to parameters of spinal sagittal alignment (sacral tilt, pelvic tilt, pelvic incidence, and lumbar lordosis). Results Postoperative hospital stay averaged 3.3 days (range: 2–8). Previously-employed patients went back to their jobs with a mean of 32 days (range: 21–42) after the procedure. At the latest follow-up, 1 of the patients considered the outcome to be poor, 3 fair, 8 good, and 15 excellent. Twenty-four patients “would undergo the operation again.” Average pain score decreased from 9.1 ± 1.0 (SD) to 3.2 ± 2.1 (P < .01). Average ODI decreased from 50.2 ± 9.9 preoperatively to 21.7 ± 14.2 (P ≤ .01). We found the change in pelvic tilt to be an independent predictor of better clinical outcome by multivariate analysis (P < .05). Conclusions In patients with junctional failure adjacent to a previous posterolateral fusion, disc replacement at the junctional level(s), compared with osteotomy and fusion surgery, offers the advantage of maintaining segmental mobility and correcting the flat-back deformity through a single approach with less operative time and blood loss. Early- to intermediate-term results are promising. The influence of changes in spinal sagittal alignment on clinical outcome needs to be addressed in future research. Clinical Relevance This is the first study on “junctional disc replacement patients” correlating clinical outcome to changes in spinal/pelvic alignment. PMID:25802584

  20. Prevalence of Transmitted HIV Drug Resistance Among Recently Infected Persons in San Diego, CA 1996-2013.

    PubMed

    Panichsillapakit, Theppharit; Smith, Davey M; Wertheim, Joel O; Richman, Douglas D; Little, Susan J; Mehta, Sanjay R

    2016-02-01

    Transmitted drug resistance (TDR) remains an important concern when initiating antiretroviral therapy (ART). Here, we describe the prevalence and phylogenetic relationships of TDR among ART-naive, HIV-infected individuals in San Diego from 1996 to 2013. Data were analyzed from 496 participants of the San Diego Primary Infection Cohort who underwent genotypic resistance testing before initiating therapy. Mutations associated with drug resistance were identified according to the WHO-2009 surveillance list. Network and phylogenetic analyses of the HIV-1 pol sequences were used to evaluate the relationships of TDR within the context of the entire cohort. The overall prevalence of TDR was 13.5% (67/496), with an increasing trend over the study period (P = 0.005). TDR was predominantly toward nonnucleoside reverse transcriptase inhibitors (NNRTIs) [8.5% (42/496)], also increasing over the study period (P = 0.005). By contrast, TDR to protease inhibitors and nucleos(t)ide reverse transcriptase inhibitors were 4.4% (22/496) and 3.8% (19/496), respectively, and did not vary with time. TDR prevalence did not differ by age, gender, race/ethnicity, or risk factors. Using phylogenetic analysis, we identified 52 transmission clusters, including 8 with at least 2 individuals sharing the same mutation, accounting for 23.8% (16/67) of the individuals with TDR. Between 1996 and 2013, the prevalence of TDR significantly increased among recently infected ART-naive individuals in San Diego. Around one-fourth of TDR occurred within clusters of recently infected individuals. These findings highlight the importance of baseline resistance testing to guide selection of ART and for public health monitoring.

  1. Performance comparison of TDR-based systems for permanent and diffused detection of water content and leaks

    NASA Astrophysics Data System (ADS)

    Cataldo, A.; De Benedetto, E.; Cannazza, G.; Huebner, C.; Trebbels, D.

    2017-01-01

    In this work, the performance of three time domain reflectometry (TDR) instruments (with different hardware architectures, specifications and costs) is comparatively assessed. The goal is to evaluate the performance of low-cost TDR instrumentation, in view of the development of a completely permanent TDR-based monitoring solution, wherein the costs of the instrument is so low, that it can be left on-site, even unguarded, and controlled remotely. Without losing generality, the applications considered for the comparative experiments are the TDR-based detection of leaks in underground pipes and, more in general, of soil water content variations. For this reason, both laboratory and in-the-field experiments are carried out by comparatively using three TDR instruments, in conjunction with wire-like sensing elements (SEs).

  2. Time Domain Reflectometry (TDR) monitoring system for deep seated landslides

    NASA Astrophysics Data System (ADS)

    Singer, J.; Thuro, K.; Festl, J.

    2012-04-01

    In the 1980s Time Domain Reflectometry (TDR) has been introduced as a subsurface deformation monitoring system in boreholes, which allows identifying and localizing discrete deformation zones with high accuracy. While TDR offers several advantages as e.g. low costs and the possibility to continuously monitor deformation along the complete borehole,TDR was not used widespread due to the fact that the amount of deformation sometimes could not be determined accurately and in some cases no deformation was detected at all. By the definition of calibrated installation standards and the usage of advanced signal analysis methods, it is possible to overcome this and a reliable quantification of deformation using TDR is possible. In the ongoing research the attempt is made to define different TDR measuring system configurations (measuring cable and grout combinations), where each is designated for a specific geological environment. These set-ups are then calibrated in laboratory shear tests and finally tested in field, if possible by comparing them with inclinometer measurements. To date monitoring data of three different deep seated landslides in the European Alps (Gschliefgraben, Aggenalm and Triesenberg) have been collected. The field test results clearly show that the new TDR system can fulfill the expectations and the deformation can be determined with sub-centimeter accuracy if one basic prerequisite concerning the mode of deformation is fulfilled: TDR can only be used when localized shear deformation is present. Since TDR data easily can be acquired continuously as well as remotely, it is possible to use a TDR measuring system as a valuable part of a monitoring system for landslide early warning. Since 2008 such a monitoring system is in operation at the Aggenalm landslide, where the TDR subsurface deformation measurements supplement the information on surface deformation from geotechnical and geodetic measuring systems to a 3D early warning system for instable slopes.

  3. Successful treatment of a patient after sudden loss of the disc in a Björk-Shiley convexo-concave mitral prosthesis.

    PubMed

    Scalia, D; Giacomin, A; Da Col, U; Valfre, C

    1987-10-01

    The patient's survival after minor strut fracture and migration of a Björk-Shiley mitral prosthetic disc is presented. The operation was carried out in two stages: first emergency replacement of the mitral prosthesis and, later, elective removal of the dislocated disc.

  4. Replacing Shox2 with human SHOX leads to congenital disc degeneration of the temporomandibular joint in mice

    PubMed Central

    Li, Xihai; Liu, Hongbing; Gu, Shuping; Liu, Chao; Sun, Cheng; Zheng, Yuqian; Chen, YiPing

    2013-01-01

    The temporomandibular joint (TMJ) consists of the glenoid fossa arising from the otic capsule through intramembranous ossification, the fibrocartilaginous disc and the condyle, derived from the secondary cartilage by endochondral ossification. We have reported previously that cranial neural crest-specific inactivation of the homeobox gene Shox2, which is expressed in the mesenchymal cells of maxilla-mandibular junction and later in the progenitor cells and perichondrium of the developing chondyle, led to dysplasia and ankylosis of the TMJ, and replacement of the mouse Shox2 with the human SHOX gene rescued the dysplastic and ankylosis phenotypes but developed a prematurely worn out articular disc. In this study, we investigated the molecular and cellular bases for the premature wear out articular disc in the TMJ of mice carrying the human SHOX replacement allele in the Shox2 locus (referred as Shox2SHOX-KI/KI). We found that the developmental process and expression of several key genes in the TMJ of Shox2SHOX-KI/KI mice appeared similar to the controls. However, the disc of the Shox2SHOX-KI/KI TMJ exhibited a reduced level of Col I and Aggrecan, accompanied by increased activities of matrix metalloproteinases (MMPs) and a down-regulation of Ihh expression. Dramatically increased cell apoptosis in the disc was also observed. These combinatory cellular and molecular defects appear to contribute to the observed disc phenotype, suggesting that while the human SHOX can exert similar function as the mouse Shox2 in regulating early TMJ development, it apparently has a distinct function in the regulation of those molecules that are involved in tissue homeostasis. PMID:24248941

  5. Biological intervertebral disc replacement: an in vivo model and comparison of two surgical techniques to approach the rat caudal disc

    PubMed Central

    Gebhard, Harry; James, Andrew R.; Bowles, Robby D.; Dyke, Jonathan P.; Saleh, Tatianna; Doty, Stephen P.; Bonassar, Lawrence J.; Härtl, Roger

    2011-01-01

    Study design: Prospective randomized animal study. Objective: To determine a surgical technique for reproducible and functional intervertebral disc replacement in an orthotopic animal model. Methods: The caudal 3/4 intervertebral disc (IVD) of the rat tail was approached by two surgical techniques: blunt dissection, stripping and retracting (Technique 1) or incising and repairing (Technique 2) the dorsal longitudinal tendons. The intervertebral disc was dissected and removed, and then either discarded or reinserted. Outcome measures were perioperative complications, spontaneous tail movement, 7T MRI (T1- and T2-sequences for measurement of disc space height (DSH) and disc hydration). Microcomputed tomographic imaging (micro CT) was additionally performed postmortem. Results: No vascular injuries occurred and no systemic or local infections were observed over the course of 1 month. Tail movements were maintained. With tendon retraction (Technique 1) gross loss of DSH occurred with both discectomy and reinsertion. Tendon division (Technique 2) maintained DSH with IVD reinsertion but not without. The DSH was demonstrated on MRI measurement. A new scoring system to assess IVD appearances was described. Conclusions: The rat tail model, with a tendon dividing surgical technique, can function as an orthotopic animal model for IVD research. Mechanical stimulation is maintained by preserved tail movements. 7T MRI is a feasible modality for longitudinal monitoring for the rat caudal disc. PMID:22956934

  6. Increase of Transmitted Drug Resistance among HIV-Infected Sub-Saharan Africans Residing in Spain in Contrast to the Native Population

    PubMed Central

    Yebra, Gonzalo; de Mulder, Miguel; Pérez-Elías, María Jesús; Pérez-Molina, José Antonio; Galán, Juan Carlos; Llenas-García, Jara; Moreno, Santiago; Holguín, África

    2011-01-01

    Background The prevalence of transmitted HIV drug resistance (TDR) is stabilizing or decreasing in developed countries. However, this trend is not specifically evaluated among immigrants from regions without well-implemented antiretroviral strategies. Methods TDR trends during 1996–2010 were analyzed among naïve HIV-infected patients in Spain, considering their origin and other factors. TDR mutations were defined according to the World Health Organization list. Results Pol sequence was available for 732 HIV-infected patients: 292 native Spanish, 226 sub-Saharan Africans (SSA), 114 Central-South Americans (CSA) and 100 from other regions. Global TDR prevalence was 9.7% (10.6% for Spanish, 8.4% for SSA and 7.9% for CSA). The highest prevalences were found for protease inhibitors (PI) in Spanish (3.1%), for non-nucleoside reverse transcriptase inhibitors (NNRTI) in SSA (6.5%) and for nucleoside reverse transcriptase inhibitors (NRTI) in both Spanish and SSA (6.5%). The global TDR rate decreased from 11.3% in 2004–2006 to 8.4% in 2007–2010. Characteristics related to a decreasing TDR trend in 2007-10 were Spanish and CSA origin, NRTI- and NNRTI-resistance, HIV-1 subtype B, male sex and infection through injection drug use. TDR remained stable for PI-resistance, in patients infected through sexual intercourse and in those carrying non-B variants. However, TDR increased among SSA and females. K103N was the predominant mutation in all groups and periods. Conclusion TDR prevalence tended to decrease among HIV-infected native Spanish and Central-South Americans, but it increased up to 13% in sub-Saharan immigrants in 2007–2010. These results highlight the importance of a specific TDR surveillance among immigrants to prevent future therapeutic failures, especially when administering NNRTIs. PMID:22046345

  7. Transmitted HIV Drug Resistance Is High and Longstanding in Metropolitan Washington, DC

    PubMed Central

    Kassaye, Seble G.; Grossman, Zehava; Balamane, Maya; Johnston-White, Betsy; Liu, Chenglong; Kumar, Princy; Young, Mary; Sneller, Michael C.; Sereti, Irini; Dewar, Robin; Rehm, Catherine; Meyer, William; Shafer, Robert; Katzenstein, David; Maldarelli, Frank

    2016-01-01

    Background. Washington, DC, has 2.5% human immunodeficiency virus (HIV) prevalence, 3.9% among African Americans. Antiretrovirals (ARTs) are the cornerstone for treatment and prevention. Monitoring changes in transmitted drug resistance (TDR) is critical for effective HIV care. Methods. HIV genotype data for individuals enrolled in research studies in metropolitan Washington, D.C., were used to identify TDR using the World Health Organization mutation list [Bennett DE, Camacho RJ, Otelea D, et al. Drug resistance mutations for surveillance of transmitted HIV-1 drug-resistance: 2009 update. PloS One 2009; 4:e4724]. HIV phylogenies were reconstructed using maximum likelihood and Bayesian methods. HIV transmission clusters were supported by 1000 bootstrap values >0.70 and posterior probability >0.95 of having a common ancestor. Results. Among 710 individuals enrolled in 1994–2013, the median age was 38.6 years, 46.2% were female, and 53.3% were African-American. TDR was 22.5% among 566 treatment-naive individuals; 15.8% had nucleoside/nucleotide reverse transcriptase inhibitor (NRTI) resistance, 9.8% had nonnucleoside reverse-transcriptase inhibitor (NNRTI) resistance, and 4.2% had protease inhibitor (PI) resistance. Single class TDR was 10.0%, 5.1%, and 1.6% to NRTIs, NNRTIs, and PIs. Dual TDR to PI and NRTI was seen in 1.6%, NRTI and NNRTI in 3.4%, and triple class TDR in 0.9%. TDR frequency decreased from 1994–2006 (27.1%) to 2007–2013 (19.4%; P = .02). Only 6/79 (7.6%) individuals within transmission clusters had evidence of TDR. Discussions. We identified high prevalence of TDR among HIV-infected individuals in metropolitan Washington, DC, regardless of gender. Active surveillance for TDR is needed to guide ART usage and analyses of risk group contributions to HIV transmission and resistance. PMID:27307507

  8. Comparison of performance of inclinometer casing and TDR technique

    NASA Astrophysics Data System (ADS)

    Aghda, S. M. Fatemi; Ganjalipour, K.; Nabiollahi, K.

    2018-03-01

    TDR (Time Domain Reflectometry) and GPR (Ground Penetrating Radar) are two of the electromagnetic methods in applied geophysics, which using them for various applications are developing. The Time Domain Reflectometry is a remote sensing method that has been used for years to determine the nature of the materials and spatial location. The use of TDR system has led to innovative applications of it and comparing it with previous measuring techniques, since it has developed. In this study, not only a summary of the basics of TDR application for monitoring of ground deformation is offered, but also a comparison of this technology with other measurement techniques (inclinometer casing) is provided. Actually, this paper presents a case study in which the opportunity arose to compare these two technologies in detecting subsurface deformation in slopes. A TDR system includes a radar wave receiver & generator, a transmission line and a waveguide. The generated electro-magnetic pulse moves toward the waveguide within the conductor cable and enters the test environment. For this study, slopes overlooking the Darian dam bottom outlet, power house and spillway were instrumented with RG59/U coaxial cables for TDR monitoring and slope inclinometer. Coaxial cables - as a TDR sensor - and inclinometer casings were installed in a same bore hole where coaxial cable was attached to the inclinometer casing. Shear and tensile deformations of the cable, which is caused by ground movements, significantly impacts on cable reflection coefficient. In Darian dam boreholes, the cable points subject to the shear and stretch were correlated with deformation points of the inclinometer casings in incremental displacement graphs. This study shows that TDR technique is more sensitive than inclinometer casing for small movement in the slide planes. Because manual processing of TDR data is hard and need experienced personnel, the authors have designed an algorithm to compare the shape of the new TDR waveforms with the base reading waveform in order to monitor the subsurface deformations.

  9. A comparison of retraction pressure during anterior cervical plate surgery and cervical disc replacement: a cadaveric study.

    PubMed

    Tortolani, P Justin; Cunningham, Bryan W; Vigna, Franco; Hu, Nianbin; Zorn, Candace M; McAfee, Paul C

    2006-07-01

    Dysphagia is a well-recognized complication after anterior cervical discectomy and fusion, observed in as high as 50% of cases by videofluoroscopic evaluation postoperatively. Esophageal injury due to surgical retraction is a complication due to which swallowing difficulties may ensue. There are limited published data evaluating the effect of soft tissue retraction on intraesophageal pressures during anterior cervical instrumentation procedures. The purpose of this study was to (a) measure the intraesophageal pressure secondary to retraction during anterior instrumentation, (b) determine whether any pressure differences exist between plating and cervical disc replacement, and (c) determine whether the surgical level or length of the plate influences the magnitude of intraesophageal pressure during retraction. An analysis of soft tissue retraction pressure was performed for anterior single-level and 3-level cervical plating and cervical disc replacement procedures. Using a 4-cm transverse incision, a Smith-Robinson anterior approach to the cervical spine was performed on 7 fresh, frozen cadavers. The correct placement of an esophageal pressure-transducing catheter was confirmed by laryngoscopy, manual palpation of the esophagus, and fluoroscopic imaging. Three surgical instrumentation groups were used for comparisons: (a) single-level plate (b) single-level Porous Coated Motion cervical disc replacement, and (c) 3-level plate. Hand-held appendiceal retractors were used to retract the soft tissues during screw insertion into the plate and during application of the disc prosthesis into the interspace. Care was taken to exert just enough force on the retractors to allow the surgeon to move the desired implant into the correct position. In addition the individual performing the retraction was blinded to the procedure being performed-1-level plating, 3-level plating, or disk replacement. Fluoroscopy confirmed that the pressure sensors were directly behind the retractors during data acquisition. Significantly greater intraesophageal pressures were demonstrated for single-level cervical plating at C5-6 compared to that at C3-4 (P=0.036). Similarly, significantly greater pressures were recorded at C5-6 versus C3-4 for the 3-level plating group (P<0.001). In contrast, there was no statistically significant difference in pressures observed during disk replacement at C5-6 compared to that at C3-4 (P=0.084). Significantly greater pressures were recorded during single-level plating compared to disc replacement at both C3-4 (P=0.016) and C5-6 (P=0.016). Three-level plating demonstrated significantly greater pressures at C5-6 compared to disk replacement (P<0.001) but no statistically significant difference compared to disk replacement at C3-4 (P=0.333). The highest mean pressure, 154.5+/-49.5 mm Hg, was recorded at C5-6 level during insertion of the 3-level plates. On the basis of the data presented here, anterior cervical plating results in significantly greater intraesophageal pressures when performed at C5-6 compared to C3-4. This holds regardless of whether the plate spans the distance from C3 to C6 (3-level plate) or the single C5-6 level. In addition, the insertion of the cervical disc replacement seems to require less esophageal retraction and hence reduced intraesophageal pressures when compared to anterior cervical plating.

  10. Transmitted drug resistance and type of infection in newly diagnosed HIV-1 individuals in Honduras.

    PubMed

    Murillo, Wendy; Paz-Bailey, Gabriela; Morales, Sonia; Monterroso, Edgar; Paredes, Mayte; Dobbs, Trudy; Parekh, Bharat S; Albert, Jan; Rivera, Ivette Lorenzana de

    2010-12-01

    Transmitted drug resistance (TDR) reduces the efficacy of antiretroviral treatment and is a public health concern. To gain insight in the epidemiology of TDR in Honduras by evaluating the amount of TDR in a representative sample of newly diagnosed individuals and by determining whether these are recent or established infections. Two hundred treatment-naïve, newly diagnosed HIV-positive individuals representing different population groups (general population, Garifunas ethnic group, female sex workers and men who have sex with men) and different geographic regions were enrolled during April 2004-April 2007. The HIV-1 pol gene was sequenced to identify drug-resistant mutations and TDR was scored as recommended by the WHO. Specimens were classified as recent or established infections using the BED assay. Among 200 samples analyzed from Honduran patients the prevalence of TDR was 7% (95% CI: 3.9-11.5%), 5% for non-nucleoside reverse transcriptase inhibitors (NNRTIs), 3% for nucleoside reverse transcriptase inhibitors (NRTIs) and 0.5% for protease inhibitors (PIs). Testing of these samples with the BED assay revealed that 12% of the specimens were associated with recent infections. TDR was significantly more common in specimens with recent infection (21%) than established infection (5%) (p=0.016). The prevalence of TDR in Honduras was moderate (7%). The percentage of specimens who were recently infected was low (12%), suggesting that late HIV diagnosis is common. The TDR prevalence was higher in recent than in established infections, which may indicate that TDR is increasing over time. The higher prevalence of NNRTI and NRTI mutations as compared to PI mutations is probably due to a broader and longer use of these drugs in Honduras. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery.

    PubMed

    Halic, Tansel; Kockara, Sinan; Bayrak, Coskun; Rowe, Richard

    2010-10-07

    Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians' training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called registration. This issue was overcome by a two-way (virtual object to real domain and real domain to virtual object) semi-automatic registration method. The applicability of the VICON MR setting for the ACDR surgical simulator is demonstrated. The main stream problems encountered in MR surgical simulator development are addressed. First, an effective environment for MR surgical development is constructed. Second, the strain and the stress intensities and critical forces are simulated under the various rasp instrument loadings with impacts that are applied on intervertebral surfaces of the anterior vertebrae throughout the rasping procedure. Third, two approaches are introduced to solve the registration problem in MR setting. Results show that our system creates an effective environment for surgical simulation development and solves tedious and time-consuming registration problems caused by misalignments. Further, the MR ACDR surgery simulator was tested by 5 different physicians who found that the MR simulator is effective enough to teach the anatomical details of cervical discs and to grasp the basics of the ACDR surgery and rasping procedure.

  12. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery

    PubMed Central

    2010-01-01

    Background Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians’ training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. Findings A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called registration. This issue was overcome by a two-way (virtual object to real domain and real domain to virtual object) semi-automatic registration method. Conclusions The applicability of the VICON MR setting for the ACDR surgical simulator is demonstrated. The main stream problems encountered in MR surgical simulator development are addressed. First, an effective environment for MR surgical development is constructed. Second, the strain and the stress intensities and critical forces are simulated under the various rasp instrument loadings with impacts that are applied on intervertebral surfaces of the anterior vertebrae throughout the rasping procedure. Third, two approaches are introduced to solve the registration problem in MR setting. Results show that our system creates an effective environment for surgical simulation development and solves tedious and time-consuming registration problems caused by misalignments. Further, the MR ACDR surgery simulator was tested by 5 different physicians who found that the MR simulator is effective enough to teach the anatomical details of cervical discs and to grasp the basics of the ACDR surgery and rasping procedure PMID:20946594

  13. Design of access-tube TDR sensor for soil water content: Theory

    USDA-ARS?s Scientific Manuscript database

    The design of a cylindrical access-tube mounted waveguide was developed for in-situ soil water content sensing using time-domain reflectometry (TDR). To optimize the design with respect to sampling volume and losses, we derived the electromagnetic fields produced by a TDR sensor with cylindrical geo...

  14. Toroidal resonance: Relation to pygmy mode, vortical properties, and anomalous deformation splitting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nesterenko, V. O., E-mail: nester@theor.jinr.ru; Kvasil, J.; Repko, A.

    2016-11-15

    We review a recent progress in investigation of the isoscalar toroidal dipole resonance (TDR). A possible relation of the TDR and low-energy dipole excitations (also called a pygmy resonance) is analyzed. It is shown that the dipole strength in the pygmy region can be understood as a local manifestation of the collective vortical toroidalmotion at the nuclear surface. Application of the TDR as a measure of the nuclear dipole vorticity is discussed. An anomalous splitting of the TDR in deformed nuclei is inspected.

  15. [Displacement and tissue remodeling of temporomandibular joint disc].

    PubMed

    Wang, M Q

    2017-03-09

    Sounding takes the highest prevalence of the signs of temporomandibular disorders (TMD). The well accepted theory of the mechanism for temporomandibular joint (TMJ) sounding is the internal derangement typically characterized by disc displacement. However, according to literature, there are approximately one third of asymptomatic joints in population had disc displacement, and, on the other hand, there are one fourth of TMJ sounding patients had not signs or very limited signs of disc displacement. Replacing the displaced disc to the normal position via methods like surgical operation did not achieve satisfactory long-term outcomes. In this review, we discuss and analyze the possible remodeling of the joint disc displacement diagnosed with imaging based on the anatomy and pathophysiology.

  16. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement.

    PubMed

    Yi, Seong; Kim, Keung Nyun; Yang, Moon Sul; Yang, Joong Won; Kim, Hoon; Ha, Yoon; Yoon, Do Heum; Shin, Hyun Chul

    2010-07-15

    Retrospective study of the difference of heterotopic ossification (HO) occurrence according to 3 different types of prosthesis. This study was designed to investigate the difference of HO occurrence according to different type of prosthesis. HO is defined as formation of the bone outside the skeletal system. Reported HO occurrence rate in cervical artificial disc replacement (ADR) was unexpectedly high and varied. But the influencing factors of HO in cervical ADR have not been elucidated well. The prosthesis-related factors for making difference of HO occurrence were investigated in this study. A total of 170 patients undergoing cervical arthroplasty with the Bryan cervical disc prosthesis (Medtroic Sofamor Danek, Memphis, TN), Mobi-C disc prosthesis (LDR Medical, Troyes, France), and ProDisc-C (Synthes, Inc., West Chester, PA) were included. Cervical lateral radiographs obtained before and after surgery were used to identify HO. Occurrence rate, occurrence-free period, location, and grade of HOs were investigated according to the different prosthesis. Each prosthesis group included patients as follows: Bryan disc, 81 patients; Mobi-C, 61 patients; and ProDisc-C, 28 patients. Overall HO rate was 40.6% (69 of 170 patients). Each HO occurrence rate by prosthesis was as follows: the Bryan disc group, 21.0%; Mobi-C group, 52.5%; and the ProDisc-C group, 71.4%. In the survival analysis, all patients showed 27.1 +/- 3.7 months as the median survival. The Bryan disc group showed statistically longer survival (48.4 +/- 7.4 months) than the other groups. Occurrence of HO is an inevitable postoperative complication after cervical ADR. The occurrence rate of HO was higher than our expectation. Moreover, definite differences in occurrence rate according to the prosthesis type were identified by this study.

  17. Increase in transmitted drug resistance in migrants from sub-Saharan Africa diagnosed with HIV-1 in Sweden.

    PubMed

    Andersson, Emmi; Nordquist, Agnes; Esbjörnsson, Joakim; Flamholc, Leo; Gisslén, Magnus; Hejdeman, Bo; Marrone, Gaetano; Norrgren, Hans; Svedhem, Veronica; Wendahl, Suzanne; Albert, Jan; Sönnerborg, Anders

    2018-04-24

    To study the trends of transmitted drug resistance (TDR) in HIV-1 patients newly diagnosed in Sweden, 2010-2016. Register-based study including all antiretroviral therapy-naive patients ≥18 years diagnosed with HIV-1 in Sweden 2010-2016. Patient data and viral pol sequences were extracted from the national InfCareHIV database. TDR was defined as the presence of surveillance drug resistance mutations (SDRMs). A CD4 T-cell decline trajectory model estimated time of infection. Phylogenetic inference was used for cluster analysis. Chi-square tests and logistic regressions were used to investigate relations between TDR, epidemiological and viral factors. One thousand, seven hundred and thirteen pol sequences were analyzed, corresponding to 71% of patients with a new HIV-1 diagnosis (heterosexuals: 53%; MSM: 34%). The overall prevalence of TDR was 7.1% (95% CI 5.8-8.3%). Nonnucleoside reverse transcriptase inhibitor (NNRTI) TDR increased significantly from 1.5% in 2010 to 6.2% in 2016, and was associated to infection and/or origin in sub-Saharan Africa (SSA). An MSM transmission cluster dating back to the 1990s with the M41L SDRM was identified. Twenty-five (1.5%) patients exhibited TDR to tenofovir (TDF; n = 8), emtricitabine/lamivudine (n = 9) or both (n = 8). NNRTI TDR has increased from 2010 to 2016 in HIV-1-infected migrants from SSA diagnosed in Sweden, mirroring the situation in SSA. TDR to tenofovir/emtricitabine, used in preexposure prophylaxis, confirms the clinical and epidemiological need for resistance testing in newly diagnosed patients.

  18. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device.

    PubMed

    Coogan, Jessica S; Francis, W Loren; Eliason, Travis D; Bredbenner, Todd L; Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A; Nicolella, Daniel P

    2016-01-01

    Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.

  19. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

    PubMed Central

    Coogan, Jessica S.; Francis, W. Loren; Eliason, Travis D.; Bredbenner, Todd L.; Stemper, Brian D.; Yoganandan, Narayan; Pintar, Frank A.; Nicolella, Daniel P.

    2016-01-01

    Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3–L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3–L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus. PMID:27990418

  20. A 6-DOF parallel bone-grinding robot for cervical disc replacement surgery.

    PubMed

    Tian, Heqiang; Wang, Chenchen; Dang, Xiaoqing; Sun, Lining

    2017-12-01

    Artificial cervical disc replacement surgery has become an effective and main treatment method for cervical disease, which has become a more common and serious problem for people with sedentary work. To improve cervical disc replacement surgery significantly, a 6-DOF parallel bone-grinding robot is developed for cervical bone-grinding by image navigation and surgical plan. The bone-grinding robot including mechanical design and low level control is designed. The bone-grinding robot navigation is realized by optical positioning with spatial registration coordinate system defined. And a parametric robot bone-grinding plan and high level control have been developed for plane grinding for cervical top endplate and tail endplate grinding by a cylindrical grinding drill and spherical grinding for two articular surfaces of bones by a ball grinding drill. Finally, the surgical flow for a robot-assisted cervical disc replacement surgery procedure is present. The final experiments results verified the key technologies and performance of the robot-assisted surgery system concept excellently, which points out a promising clinical application with higher operability. Finally, study innovations, study limitations, and future works of this present study are discussed, and conclusions of this paper are also summarized further. This bone-grinding robot is still in the initial stage, and there are many problems to be solved from a clinical point of view. Moreover, the technique is promising and can give a good support for surgeons in future clinical work.

  1. Design and testing of access-tube TDR soil water sensor

    USDA-ARS?s Scientific Manuscript database

    We developed the design of a waveguide on the exterior of an access tube for use in time-domain reflectometry (TDR) for in-situ soil water content sensing. In order to optimize the design with respect to sampling volume and losses, we derived the electromagnetic (EM) fields produced by a TDR sensor...

  2. Cross-Shear Implementation in Sliding-Distance-Coupled Finite Element Analysis of Wear in Metal-on-Polyethylene Total Joint Arthroplasty: Intervertebral Total Disc Replacement as an Illustrative Application

    PubMed Central

    Goreham-Voss, Curtis M.; Hyde, Philip J.; Hall, Richard M.; Fisher, John; Brown, Thomas D.

    2010-01-01

    Computational simulations of wear of orthopaedic total joint replacement implants have proven to valuably complement laboratory physical simulators, for pre-clinical estimation of abrasive/adhesive wear propensity. This class of numerical formulations has primarily involved implementation of the Archard/Lancaster relationship, with local wear computed as the product of (finite element) contact stress, sliding speed, and a bearing-couple-dependent wear factor. The present study introduces an augmentation, whereby the influence of interface cross-shearing motion transverse to the prevailing molecular orientation of the polyethylene articular surface is taken into account in assigning the instantaneous local wear factor. The formulation augment is implemented within a widely-utilized commercial finite element software environment (ABAQUS). Using a contemporary metal-on-polyethylene total disc replacement (ProDisc-L) as an illustrative implant, physically validated computational results are presented to document the role of cross-shearing effects in alternative laboratory consensus testing protocols. Going forward, this formulation permits systematically accounting for cross-shear effects in parametric computational wear studies of metal-on-polyethylene joint replacements, heretofore a substantial limitation of such analyses. PMID:20399432

  3. Successful Prevention of Transmission of Integrase Resistance in the Swiss HIV Cohort Study.

    PubMed

    Scherrer, Alexandra U; Yang, Wan-Lin; Kouyos, Roger D; Böni, Jürg; Yerly, Sabine; Klimkait, Thomas; Aubert, Vincent; Cavassini, Matthias; Battegay, Manuel; Hauser, Christoph; Calmy, Alexandra; Schmid, Patrick; Bernasconi, Enos; Günthard, Huldrych F

    2016-08-01

    The prevalence of integrase strand transfer inhibitor (INSTI)-transmitted drug resistance (TDR) may increase with the increasing use of INSTIs. We analyzed the prevalence of INSTI TDR in the Swiss HIV Cohort Study (2008-2014). In 1 of 1316 drug-naive samples (0.1%), a major INSTI TDR mutation was detected. Prevalence was stable, although INSTIs were increasingly used. We showed that this is in contrast to the introduction of previous drug classes, in which more treatment failures with resistant strains occurred and TDR was observed more rapidly. We demonstrated on a population-level that it is possible to avoid TDR to a new drug class for years. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  4. A New Non-Destructive TDR System Combined with a Piezoelectric Stack for Measuring Properties of Geomaterials

    PubMed Central

    Choi, Chanyong; Song, Minwoo; Kim, Daehyeon; Yu, Xiong

    2016-01-01

    Dry density and water content are two important factors affecting the degree of soil compaction. Conventional methods such as the sand cone test and the plate load test are used to measure such properties for evaluating the degree of compaction and the stiffness of soil in the field. However, these tests are generally very time-consuming and are inherent with some errors depending on the operator (in particular for the sand cone test). Elastic modulus is an indicator to describe the stress-strain behavior of soil and in some cases is used as a design input parameter. Although a rod type TDR (Time Domain Reflectometry) system has been recently proposed to overcome some shortcomings of the conventional methods (particularly the sand cone test), it requires driving the probes into the ground, thus implying that it is still a time-consuming and destructive testing method. This study aims to develop a new non-destructive TDR system that can rapidly measure the dry density, water content, and elastic modulus of soil on the surface of compacted soil, without disturbing the ground. In this study, the Piezoelectric Stack, which is an instrument for measuring the elastic modulus of soil, has been added to the TDR system with a flat type probe, leading to a non-destructive TDR system that is capable of measuring the dry density, water content, and elastic modulus of soil. The new TDR system developed is light enough for an engineer to carry. Results of the standard compaction and TDR tests on sand showed that the dry densities and the moisture contents measured with the new TDR system were in good agreement with those measured with the standard compaction test, respectively. Consequently, it appears that the new TDR system developed will be very useful to advance the current practice of compaction quality control. PMID:28773563

  5. Transmitted antiretroviral drug resistance in the men who have sex with men HIV patient cohort, Beijing, China, 2008-2011.

    PubMed

    Dai, Lili; Li, Ning; Wei, Feili; Li, Jingyun; Liu, Yongjian; Xia, Wei; Zhang, Tong; Guo, Caiping; Wang, Wen; Schwartz, Stanley A; Mahajan, Supriya D; Hsiao, Chiu-Bin; Wu, Hao

    2014-10-01

    Transmitted drug resistance (TDR) is an ongoing public health problem in HIV disease treatment. However, little is known about TDR among men who have sex with men (MSM) patients in China. In addition, TDR prevalence among patients with acute HIV infection (AHI) or early HIV infection (EHI) was believed higher than that of patients with chronic HIV infection (CHI), but as AHI is typically either unidentified or crudely defined in large populations, very few direct comparisons have been made. We did a retrospective analysis of TDR in 536 antiretroviral-naive MSM patients from our immunodeficiency clinics at You'an Hospital, Capital Medical University (CMU), in Beijing, China, 2008-2011. The cohort included 266 patients with AHI/EHI and 270 patients with CHI. We analyzed the subtype, estimated the TDR prevalence, and characterized the model of TDR and the predicted drug sensitivity. Additionally, we made a comparison of TDR between the patients with AHI/EHI and patients with CHI. Our results indicated that among the 536 patients, HIV-1 subtype CRF01_AE accounted for 52.1%, subtype B accounted for 24.8%, CRF07_BC/ CRF08_BC accounted for 21.6% (116/536), and 1.3% were denoted as unique recombinant forms (URFs). A total of 7.8% patients had one or more transmitted HIV-1 drug resistance mutations, representing 6.2% for PI-related mutations, 0.9% for NRTI-related mutations, and 1.7% for NNRTI-related mutations. Although patients with AHI/EHI had a higher TDR prevalence as compared to that of patients with CHI, the difference was not statistically significant. There was no significant difference in TDR model and predicted drug susceptibility between the two groups of patients either. This study provides important strategic information for public health planning by healthcare officials in China and warrants a comprehensive study with larger patient cohorts from various healthcare centers within China.

  6. A New Non-Destructive TDR System Combined with a Piezoelectric Stack for Measuring Properties of Geomaterials.

    PubMed

    Choi, Chanyong; Song, Minwoo; Kim, Daehyeon; Yu, Xiong

    2016-06-02

    Dry density and water content are two important factors affecting the degree of soil compaction. Conventional methods such as the sand cone test and the plate load test are used to measure such properties for evaluating the degree of compaction and the stiffness of soil in the field. However, these tests are generally very time-consuming and are inherent with some errors depending on the operator (in particular for the sand cone test). Elastic modulus is an indicator to describe the stress-strain behavior of soil and in some cases is used as a design input parameter. Although a rod type TDR (Time Domain Reflectometry) system has been recently proposed to overcome some shortcomings of the conventional methods (particularly the sand cone test), it requires driving the probes into the ground, thus implying that it is still a time-consuming and destructive testing method. This study aims to develop a new non-destructive TDR system that can rapidly measure the dry density, water content, and elastic modulus of soil on the surface of compacted soil, without disturbing the ground. In this study, the Piezoelectric Stack, which is an instrument for measuring the elastic modulus of soil, has been added to the TDR system with a flat type probe, leading to a non-destructive TDR system that is capable of measuring the dry density, water content, and elastic modulus of soil. The new TDR system developed is light enough for an engineer to carry. Results of the standard compaction and TDR tests on sand showed that the dry densities and the moisture contents measured with the new TDR system were in good agreement with those measured with the standard compaction test, respectively. Consequently, it appears that the new TDR system developed will be very useful to advance the current practice of compaction quality control.

  7. The Rice Basic Helix-Loop-Helix Transcription Factor TDR INTERACTING PROTEIN2 Is a Central Switch in Early Anther Development[C][W

    PubMed Central

    Fu, Zhenzhen; Yu, Jing; Cheng, Xiaowei; Zong, Xu; Xu, Jie; Chen, Mingjiao; Li, Zongyun; Zhang, Dabing; Liang, Wanqi

    2014-01-01

    In male reproductive development in plants, meristemoid precursor cells possessing transient, stem cell–like features undergo cell divisions and differentiation to produce the anther, the male reproductive organ. The anther contains centrally positioned microsporocytes surrounded by four distinct layers of wall: the epidermis, endothecium, middle layer, and tapetum. Here, we report that the rice (Oryza sativa) basic helix-loop-helix (bHLH) protein TDR INTERACTING PROTEIN2 (TIP2) functions as a crucial switch in the meristemoid transition and differentiation during early anther development. The tip2 mutants display undifferentiated inner three anther wall layers and abort tapetal programmed cell death, causing complete male sterility. TIP2 has two paralogs in rice, TDR and EAT1, which are key regulators of tapetal programmed cell death. We revealed that TIP2 acts upstream of TDR and EAT1 and directly regulates the expression of TDR and EAT1. In addition, TIP2 can interact with TDR, indicating a role of TIP2 in later anther development. Our findings suggest that the bHLH proteins TIP2, TDR, and EAT1 play a central role in regulating differentiation, morphogenesis, and degradation of anther somatic cell layers, highlighting the role of paralogous bHLH proteins in regulating distinct steps of plant cell–type determination. PMID:24755456

  8. Does location of rotation center in artificial disc affect cervical biomechanics?

    PubMed

    Mo, Zhongjun; Zhao, Yanbin; Du, Chengfei; Sun, Yu; Zhang, Ming; Fan, Yubo

    2015-04-15

    A 3-dimensional finite element investigation. To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Implantation of 5 prostheses was simulated at C5-C6 on the basis of a validated finite element cervical model (C3-C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implant interface. Cervical stability was extremely affected in extension and partially affected in flexion by total disc replacement. With the prostheses with mobile RC, cervical curvature was readjusted under a low follower load. The SA-V and BS-FS designs exhibited better performances in the entire segmental stiffness and in the stability of the operative level than the BS-MI and BS-FI designs in flexion. The 5 designs demonstrated varying advantages relative to the stress distribution in the facet cartilages and on the bone-implant interface. 5.

  9. Towards elimination of visceral leishmaniasis in the Indian subcontinent-Translating research to practice to public health.

    PubMed

    Hirve, Siddhivinayak; Kroeger, Axel; Matlashewski, Greg; Mondal, Dinesh; Banjara, Megha Raj; Das, Pradeep; Be-Nazir, Ahmed; Arana, Byron; Olliaro, Piero

    2017-10-01

    The decade following the Regional Strategic Framework for Visceral Leishmaniasis (VL) elimination in 2005 has shown compelling progress in the reduction of VL burden in the Indian subcontinent. The Special Programme for Research and Training in Tropical Diseases (TDR), hosted by the World Health Organization (WHO) and other stakeholders, has coordinated and financed research for the development of new innovative tools and strategies to support the regional VL elimination initiative. This paper describes the process of the TDR's engagement and contribution to this initiative. Multiple databases were searched to identify 152 scientific papers and reports with WHO funding or authorship affiliation around the following 3 framework strategies: detection of new cases, morbidity reduction, and prevention of infection. TDR has played a critical role in the evaluation and subsequent use of the 39-aminoacid-recombinant kinesin antigen (rK39) rapid diagnostic test (RDT) as a confirmatory test for VL in the national program. TDR has supported the clinical research and development of miltefosine and single-dose liposomal amphotericin B as a first-line treatment against VL. TDR has engaged with in-country researchers, national programme managers, and partners to generate evidence-based interventions for early detection and treatment of VL patients. TDR evaluated the quality, community acceptance, and cost effectiveness of indoor residual spraying, insecticide-treated bed nets, insecticide-impregnated durable wall linings, insecticidal paint, and environmental management as tools for integrated vector management in reducing sandfly density. TDR's engagement with country policy makers, scientists, and clinicians in the development of effective diagnosis, treatment, case detection, and vector control represents an important example of TDR's stewardship toward the elimination of VL in the Indian subcontinent.

  10. Transmission of HIV Drug Resistance and the Predicted Effect on Current First-line Regimens in Europe.

    PubMed

    Hofstra, L Marije; Sauvageot, Nicolas; Albert, Jan; Alexiev, Ivailo; Garcia, Federico; Struck, Daniel; Van de Vijver, David A M C; Åsjö, Birgitta; Beshkov, Danail; Coughlan, Suzie; Descamps, Diane; Griskevicius, Algirdas; Hamouda, Osamah; Horban, Andrzej; Van Kasteren, Marjo; Kolupajeva, Tatjana; Kostrikis, Leondios G; Liitsola, Kirsi; Linka, Marek; Mor, Orna; Nielsen, Claus; Otelea, Dan; Paraskevis, Dimitrios; Paredes, Roger; Poljak, Mario; Puchhammer-Stöckl, Elisabeth; Sönnerborg, Anders; Staneková, Danica; Stanojevic, Maja; Van Laethem, Kristel; Zazzi, Maurizio; Zidovec Lepej, Snjezana; Boucher, Charles A B; Schmit, Jean-Claude; Wensing, Annemarie M J; Puchhammer-Stockl, E; Sarcletti, M; Schmied, B; Geit, M; Balluch, G; Vandamme, A-M; Vercauteren, J; Derdelinckx, I; Sasse, A; Bogaert, M; Ceunen, H; De Roo, A; De Wit, S; Echahidi, F; Fransen, K; Goffard, J-C; Goubau, P; Goudeseune, E; Yombi, J-C; Lacor, P; Liesnard, C; Moutschen, M; Pierard, D; Rens, R; Schrooten, Y; Vaira, D; Vandekerckhove, L P R; Van den Heuvel, A; Van Der Gucht, B; Van Ranst, M; Van Wijngaerden, E; Vandercam, B; Vekemans, M; Verhofstede, C; Clumeck, N; Van Laethem, K; Beshkov, D; Alexiev, I; Lepej, S Zidovec; Begovac, J; Kostrikis, L; Demetriades, I; Kousiappa, I; Demetriou, V; Hezka, J; Linka, M; Maly, M; Machala, L; Nielsen, C; Jørgensen, L B; Gerstoft, J; Mathiesen, L; Pedersen, C; Nielsen, H; Laursen, A; Kvinesdal, B; Liitsola, K; Ristola, M; Suni, J; Sutinen, J; Descamps, D; Assoumou, L; Castor, G; Grude, M; Flandre, P; Storto, A; Hamouda, O; Kücherer, C; Berg, T; Braun, P; Poggensee, G; Däumer, M; Eberle, J; Heiken, H; Kaiser, R; Knechten, H; Korn, K; Müller, H; Neifer, S; Schmidt, B; Walter, H; Gunsenheimer-Bartmeyer, B; Harrer, T; Paraskevis, D; Hatzakis, A; Zavitsanou, A; Vassilakis, A; Lazanas, M; Chini, M; Lioni, A; Sakka, V; Kourkounti, S; Paparizos, V; Antoniadou, A; Papadopoulos, A; Poulakou, G; Katsarolis, I; Protopapas, K; Chryssos, G; Drimis, S; Gargalianos, P; Xylomenos, G; Lourida, G; Psichogiou, M; Daikos, G L; Sipsas, N V; Kontos, A; Gamaletsou, M N; Koratzanis, G; Sambatakou, H; Mariolis, H; Skoutelis, A; Papastamopoulos, V; Georgiou, O; Panagopoulos, P; Maltezos, E; Coughlan, S; De Gascun, C; Byrne, C; Duffy, M; Bergin, C; Reidy, D; Farrell, G; Lambert, J; O'Connor, E; Rochford, A; Low, J; Coakely, P; O'Dea, S; Hall, W; Mor, O; Levi, I; Chemtob, D; Grossman, Z; Zazzi, M; de Luca, A; Balotta, C; Riva, C; Mussini, C; Caramma, I; Capetti, A; Colombo, M C; Rossi, C; Prati, F; Tramuto, F; Vitale, F; Ciccozzi, M; Angarano, G; Rezza, G; Kolupajeva, T; Vasins, O; Griskevicius, A; Lipnickiene, V; Schmit, J C; Struck, D; Sauvageot, N; Hemmer, R; Arendt, V; Michaux, C; Staub, T; Sequin-Devaux, C; Wensing, A M J; Boucher, C A B; van de Vijver, D A M C; van Kessel, A; van Bentum, P H M; Brinkman, K; Connell, B J; van der Ende, M E; Hoepelman, I M; van Kasteren, M; Kuipers, M; Langebeek, N; Richter, C; Santegoets, R M W J; Schrijnders-Gudde, L; Schuurman, R; van de Ven, B J M; Åsjö, B; Kran, A-M Bakken; Ormaasen, V; Aavitsland, P; Horban, A; Stanczak, J J; Stanczak, G P; Firlag-Burkacka, E; Wiercinska-Drapalo, A; Jablonowska, E; Maolepsza, E; Leszczyszyn-Pynka, M; Szata, W; Camacho, R; Palma, C; Borges, F; Paixão, T; Duque, V; Araújo, F; Otelea, D; Paraschiv, S; Tudor, A M; Cernat, R; Chiriac, C; Dumitrescu, F; Prisecariu, L J; Stanojevic, M; Jevtovic, Dj; Salemovic, D; Stanekova, D; Habekova, M; Chabadová, Z; Drobkova, T; Bukovinova, P; Shunnar, A; Truska, P; Poljak, M; Lunar, M; Babic, D; Tomazic, J; Vidmar, L; Vovko, T; Karner, P; Garcia, F; Paredes, R; Monge, S; Moreno, S; Del Amo, J; Asensi, V; Sirvent, J L; de Mendoza, C; Delgado, R; Gutiérrez, F; Berenguer, J; Garcia-Bujalance, S; Stella, N; de Los Santos, I; Blanco, J R; Dalmau, D; Rivero, M; Segura, F; Elías, M J Pérez; Alvarez, M; Chueca, N; Rodríguez-Martín, C; Vidal, C; Palomares, J C; Viciana, I; Viciana, P; Cordoba, J; Aguilera, A; Domingo, P; Galindo, M J; Miralles, C; Del Pozo, M A; Ribera, E; Iribarren, J A; Ruiz, L; de la Torre, J; Vidal, F; Clotet, B; Albert, J; Heidarian, A; Aperia-Peipke, K; Axelsson, M; Mild, M; Karlsson, A; Sönnerborg, A; Thalme, A; Navér, L; Bratt, G; Karlsson, A; Blaxhult, A; Gisslén, M; Svennerholm, B; Bergbrant, I; Björkman, P; Säll, C; Mellgren, Å; Lindholm, A; Kuylenstierna, N; Montelius, R; Azimi, F; Johansson, B; Carlsson, M; Johansson, E; Ljungberg, B; Ekvall, H; Strand, A; Mäkitalo, S; Öberg, S; Holmblad, P; Höfer, M; Holmberg, H; Josefson, P; Ryding, U

    2016-03-01

    Numerous studies have shown that baseline drug resistance patterns may influence the outcome of antiretroviral therapy. Therefore, guidelines recommend drug resistance testing to guide the choice of initial regimen. In addition to optimizing individual patient management, these baseline resistance data enable transmitted drug resistance (TDR) to be surveyed for public health purposes. The SPREAD program systematically collects data to gain insight into TDR occurring in Europe since 2001. Demographic, clinical, and virological data from 4140 antiretroviral-naive human immunodeficiency virus (HIV)-infected individuals from 26 countries who were newly diagnosed between 2008 and 2010 were analyzed. Evidence of TDR was defined using the WHO list for surveillance of drug resistance mutations. Prevalence of TDR was assessed over time by comparing the results to SPREAD data from 2002 to 2007. Baseline susceptibility to antiretroviral drugs was predicted using the Stanford HIVdb program version 7.0. The overall prevalence of TDR did not change significantly over time and was 8.3% (95% confidence interval, 7.2%-9.5%) in 2008-2010. The most frequent indicators of TDR were nucleoside reverse transcriptase inhibitor (NRTI) mutations (4.5%), followed by nonnucleoside reverse transcriptase inhibitor (NNRTI) mutations (2.9%) and protease inhibitor mutations (2.0%). Baseline mutations were most predictive of reduced susceptibility to initial NNRTI-based regimens: 4.5% and 6.5% of patient isolates were predicted to have resistance to regimens containing efavirenz or rilpivirine, respectively, independent of current NRTI backbones. Although TDR was highest for NRTIs, the impact of baseline drug resistance patterns on susceptibility was largest for NNRTIs. The prevalence of TDR assessed by epidemiological surveys does not clearly indicate to what degree susceptibility to different drug classes is affected. © The Author 2015. Published by Oxford University Press for the Infectious Diseases Society of America.

  11. Determination of the intervertebral disc space from CT images of the lumbar spine

    NASA Astrophysics Data System (ADS)

    Korez, Robert; Å tern, Darko; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-03-01

    Degenerative changes of the intervertebral disc are among the most common causes of low back pain, where for individuals with significant symptoms surgery may be needed. One of the interventions is the total disc replacement surgery, where the degenerated disc is replaced by an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study we propose a method for the determination of the intervertebral disc space from three-dimensional (3D) computed tomography (CT) images of the lumbar spine. The first step of the proposed method is the construction of a model of vertebral bodies in the lumbar spine. For this purpose, a chain of five elliptical cylinders is initialized in the 3D image and then deformed to resemble vertebral bodies by introducing 25 shape parameters. The parameters are obtained by aligning the chain to the vertebral bodies in the CT image according to image intensity and appearance information. The determination of the intervertebral disc space is finally achieved by finding the planes that fit the endplates of the obtained parametric 3D models, and placing points in the space between the planes of adjacent vertebrae that enable surface reconstruction of the intervertebral disc space. The morphometric analysis of images from 20 subjects yielded 11:3 +/- 2:6, 12:1 +/- 2:4, 12:8 +/- 2:0 and 12:9 +/- 2:7 cm3 in terms of L1-L2, L2-L3, L3-L4 and L4-L5 intervertebral disc space volume, respectively.

  12. Detection and characterization of corrosion of bridge cables by time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Hunsperger, Robert G.; Folliard, Kevin; Chajes, Michael J.; Barot, Jignesh; Jhaveri, Darshan; Kunz, Eric

    1999-02-01

    In this paper, we develop and demonstrate a nondestructive evaluation technique for corrosion detection of embedded or encased steel cables. This technique utilizes time domain reflectometry (TDR), which has been traditionally used to detect electrical discontinuities in transmission lines. By applying a sensor wire along with the bridge cable, we can model the cable as an asymmetric, twin-conductor transmission line. Physical defects of the bridge cable will change the electromagnetic properties of the line and can be detected by TDR. Furthermore, different types of defects can be modeled analytically, and identified using TDR. TDR measurement results from several fabricated bridge cable sections with built-in defects are reported.

  13. Strategic emphases for tropical diseases research: a TDR perspective.

    PubMed

    Remme, Jan H F; Blas, Erik; Chitsulo, Lester; Desjeux, Philippe M P; Engers, Howard D; Kanyok, Thomas P; Kengeya Kayondo, Jane F; Kioy, Deborah W; Kumaraswami, Vasanthapuram; Lazdins, Janis K; Nunn, Paul P; Oduola, Ayoade; Ridley, Robert G; Toure, Yeya T; Zicker, Fabio; Morel, Carlos M

    2002-10-01

    Setting priorities for health research is a difficult task, especially for the neglected diseases of the poor. A new approach to priority setting for tropical diseases research has been adopted by the UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (known as the TDR). Priorities are defined on the basis of a comprehensive analysis of research needs and research opportunities for each of the ten major tropical diseases in the TDR portfolio. The resulting strategic emphases matrix reflects the priorities for tropical diseases research from the perspective of the TDR. Its purpose is not to impose global research priorities, but we believe the results could be useful to other organizations.

  14. Self-Sensing TDR with Micro-Strip Line

    DTIC Science & Technology

    2015-06-11

    detect impact damage of a CFRP plate in the second year (Todoroki A, et al., Impact damage detection of a carbon- fibre -reinforced-polymer plate...inspection methods is self-sensing technology that uses carbon fibres as sensors [1]-[11]. The self-sensing technology applies electric current to the...Time Domain Reflectometry (TDR) for damage detection [15]-[17]. Authors have developed a self-sensing TDR for detection of fibre breakages using a

  15. Active Time-Domain Reflectometry for Unattended Safeguards Systems FY15 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Moore, David E.

    2015-09-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-costmore » commercially available spread-spectrum TDR technology as one option for field implementation. This report describes PNNL’s FY15 progress in the viability study including: an overview of the TDR methods under investigation; description of the testing configurations and mock tampering scenarios; results from a preliminary sensitivity comparison of the two TDR methods; demonstration of a quantitative metric for estimating field performance that acknowledges the need for high detection probability while minimizing false alarms. FY15 progress reported here sets the stage for a rigorous comparison of the candidate TDR methods, over a range of deployment scenarios and perturbing effects typical of IAEA unattended monitoring systems.« less

  16. Do Postoperative Biomechanical Changes Induce Heterotopic Ossification After Cervical Arthroplasty?: A 5-Year Follow-up Study.

    PubMed

    Kim, Keun Su; Heo, Dong Hwa

    2016-07-01

    Prospective clinical study. To evaluate the factors that would predispose a patient to heterotopic ossification (HO) formation after cervical arthroplasty. HO after arthroplasty is one of the complications of cervical total disk replacement (TDR). However, the predisposing factors and pathophysiology of HO have not been precisely described. We prospectively enrolled and followed up 23 patients, who received single-level arthroplasty with ProDisc-C, for 5 years after the operation. The patients who developed grade 3 or 4 HO were classified into the "high-grade HO group," whereas the patients with grade 0, 1, or 2 HO were classified into the "low-grade HO group." We compared the postoperative changes in the range of motion (ROM) and height of the functional segmental unit (FSU) of the implantation segments between the 2 groups. The mean differences in height and ROM of the FSU were 2.59±1.42 mm and 6.7±3.2 degrees in the high-grade HO group, and 0.87±0.72 mm and 3.1±2.8 degrees in the low-grade HO group. The mean differences in height and ROM of the FSU were significantly higher in the high-grade HO group than in the low-grade HO group (P<0.05). After cervical arthroplasty, the height of the FSU and ROM of the implantation segments were significantly increased in the high-grade HO group compared with the low-grade HO group. Overcorrection of the height of the FSU and increase in the ROM of the implantation segment may influence the formation of HOs after cervical arthroplasty.

  17. Epidemiological surveillance of HIV-1 transmitted drug resistance among newly diagnosed individuals in Shijiazhuang, northern China, 2014-2015.

    PubMed

    Wang, Xianfeng; Liu, Xiaosong; Li, Feng; Zhou, Hong; Li, Jiefang; Wang, Yingying; Liu, Lihua; Liu, Shujun; Feng, Yi; Wang, Ning

    2018-01-01

    The widespread use of antiretroviral therapy (ART) has led to considerable concerns about the prevalence of transmitted drug resistance (TDR). Sexual contact, particularly men who have sex with men (MSM) was the most prevalent form of HIV transmission in Shijiazhuang. Hence, we conducted an epidemiological surveillance study on TDR among newly diagnosed individuals who infected-HIV through sexual contact in from 2014-2015. Genotypic resistance mutations were defined using the WHO-2009 surveillance list. Potential impact on antiretroviral drug was predicted according to the Stanford HIV db program version 7.0. The role of transmission clusters in drug resistant strains was evaluated by phylogenetic and network analyses. In this study, 589 individuals were recruited and 542 samples were amplified and sequenced successfully. The over prevalence of TDR was 6.1%: 1.8% to nucleoside reverse transcriptase inhibitors (NRTIs), 2.0% to non- NRTIs (NNRTIs) and 2.4% to protease inhibitors (PIs), respectively. We did not find significant differences in the TDR prevalence by demographic and clinical characteristics (p > 0.05). Using network and phylogenetic analysis, almost 60.0% sequences were clustered together. Of these clusters, 2 included at least two individuals carrying the same resistance mutation, accounting for 21.2% (7/33) individuals with TDR. No significant difference was observed in the clustering rate between the individuals with and without TDR. We obtained a moderate level TDR rate in studied region. These findings enhance our understanding of HIV-1 drug resistance prevalence in Shijiazhuang, and may be helpful for the comprehensive prevention and control of HIV-1.

  18. Turbulence and turbulent drag reduction in swirling flow: Inertial versus viscous forcing.

    PubMed

    Burnishev, Yuri; Steinberg, Victor

    2015-08-01

    We report unexpected results of a drastic difference in the transition to fully developed turbulent and turbulent drag reduction (TDR) regimes and in their properties in a von Karman swirling flow with counter-rotating disks of water-based polymer solutions for viscous (by smooth disks) as well as inertial (by bladed disks) forcing and by tracking just torque Γ(t) and pressure p(t) . For the viscous forcing, just a single TDR regime is found with the transition values of the Reynolds number (Re) Re turb c =Re TDR c ≃(4.8±0.2)×10(5) independent of ϕ , whereas for the inertial forcing two turbulent regimes are revealed. The first transition is to fully developed turbulence, and the second one is to the TDR regime with both Re turb c and Re TDR c depending on polymer concentration ϕ . Both regimes differ by the values of C f and C p , by the scaling exponents of the fundamental turbulent characteristics, by the nonmonotonic dependencies of skewness and flatness of the pressure PDFs on Re, and by the different frequency power spectra of p with the different dependencies of the main vortex peak frequency in the p power spectra on ϕ and Re. Thus our experimental results show the transition to the TDR regime in a von Karman swirling flow for the viscous and inertial forcings in a sharp contrast to the recent experiments [Phys. Fluids 10, 426 (1998); Phys. Rev. E 47, R28(R) (1993); and J. Phys.: Condens. Matter 17, S1195 (2005)] where the transition to TDR is observed in the same swirling flow with counter-rotating disks only for the viscous forcing. The latter result has led its authors to the wrong conclusion that TDR is a solely boundary effect contrary to the inertial forcing associated with the bulk effect, and this conception is currently rather widely accepted in literature.

  19. 77 FR 16917 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-23

    ... turbofan engines. This AD requires replacement of the high-pressure (HP) turbine spanner retaining nut... stage 2 high-pressure turbine (HPT) disc spanner retaining nuts did not receive the proper heat... HPT disc failure, possibly leading to release of high energy debris, resulting in damage to the...

  20. Anterior cervical discectomy and fusion (ACDF) versus cervical disc arthroplasty (CDA) for two contiguous levels cervical disc degenerative disease: a meta-analysis of randomized controlled trials.

    PubMed

    Zou, Shihua; Gao, Junyi; Xu, Bin; Lu, Xiangdong; Han, Yongbin; Meng, Hui

    2017-04-01

    Anterior cervical discectomy and fusion (ACDF) has been considered as a gold standard for symptomatic cervical disc degeneration (CDD), which may result in progressive degeneration of the adjacent segments. The artificial cervical disc was designed to reduce the number of lesions in the adjacent segments. Clinical studies have demonstrated equivalence of cervical disc arthroplasty (CDA) for anterior cervical discectomy and fusion in single segment cervical disc degeneration. But for two contiguous levels cervical disc degeneration (CDD), which kind of treatment method is better is controversial. To evaluate the clinical effects requiring surgical intervention between anterior cervical discectomy and fusion (ACDF) and cervical disc arthroplasty (CDA) at two contiguous levels cervical disc degeneration. We conducted a comprehensive search in multiple databases, including PubMed, Cochrane Central Register of Controlled Trials, EBSCO and EMBASE. We identified that six reports meet inclusion criteria. Two independent reviewers performed the data extraction from archives. Data analysis was conducted with RevMan 5.3. After applying inclusion and exclusion criteria, six papers were included in meta-analyses. The overall sample size at baseline was 650 patients (317 in the TDR group and 333 in the ACDF group). The results of the meta-analysis indicated that the CDA patients had significant superiorities in mean blood loss (P < 0.00001, standard mean differences (SMD) = -0.85, 95 % confidence interval (CI) = -1.22 to -0.48); reoperation (P = 0.0009, risk ratio (RR) = 0.28, 95 % confidence interval (CI) = 0.13-0.59), adjacent segment degeneration (P < 0.00001, risk ratio (RR) = 0.48, 95 % confidence interval (CI) = 0.40-0.58) and Neck Disability Index (P = 0.002, SMD = 0.31, 95 % CI = 0.12-0.50). No significant difference was identified between the two groups regarding mean surgical time (P = 0.84, SMD = -0.04, 95 % CI = -0.40 to 0.32), neck and arm pain scores (P = 0.52, SMD = 0.06, 95 % CI = -0.13 to 0.25) reported on a visual analog scale and rate of postoperative complications [risk ratio (RR) = 0.79; 95 % CI = 0.50-1.25; P = 0.31]. The CDA group of sagittal range of motion (ROM) of the operated and adjacent levels, functional segment units (FSU) and C2-7 is superior to ACDF group by radiographic data of peroperation, postoperation and follow-up. We can learn from this meta-analysis that the cervical disc arthroplasty (CDA) group is equivalent and in some aspects has more significant clinical outcomes than the ACDF group at two contiguous levels CDD.

  1. Disc dislodgment in Björk Shiley mitral valve prosthesis: two successfully operated cases.

    PubMed

    Dubernet, J; Irarrázaval, M J; Urzúa, J; Maturana, G; Morán, S; Lema, G; Asenjo, F; Fajuri, A

    1986-02-01

    Two patients with Björk Shiley mitral valve replacement had migration and embolization of the occluding disc. One patient suffered migration of the disc a few hours after surgery and the other had a strut fracture with disc translocation six years after the initial operation. Clinical signs in both cases were pulmonary edema, cardiogenic shock, and absence of prosthetic sounds. Both patients were reoperated on an emergency basis, recovering after a complicated postoperative course. They are on functional Class I, 8 and 1 years later, respectively, with their dislodged discs still in the abdominal aorta. The only hope for survival in these patients is emergency reoperation, once the prosthetic mitral valve dysfunction is confirmed.

  2. Investigation of Product Performance of Al-Metal Matrix Composites Brake Disc using Finite Element Analysis

    NASA Astrophysics Data System (ADS)

    Fatchurrohman, N.; Marini, C. D.; Suraya, S.; Iqbal, AKM Asif

    2016-02-01

    The increasing demand of fuel efficiency and light weight components in automobile sectors have led to the development of advanced material parts with improved performance. A specific class of MMCs which has gained a lot of attention due to its potential is aluminium metal matrix composites (Al-MMCs). Product performance investigation of Al- MMCs is presented in this article, where an Al-MMCs brake disc is analyzed using finite element analysis. The objective is to identify the potentiality of replacing the conventional iron brake disc with Al-MMCs brake disc. The simulation results suggested that the MMCs brake disc provided better thermal and mechanical performance as compared to the conventional cast iron brake disc. Although, the Al-MMCs brake disc dissipated higher maximum temperature compared to cast iron brake disc's maximum temperature. The Al-MMCs brake disc showed a well distributed temperature than the cast iron brake disc. The high temperature developed at the ring of the disc and heat was dissipated in circumferential direction. Moreover, better thermal dissipation and conduction at brake disc rotor surface played a major influence on the stress. As a comparison, the maximum stress and strain of Al-MMCs brake disc was lower than that induced on the cast iron brake disc.

  3. A simple approach to determine reactive solute transport using time domain reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vogeler, I.; Duwig, C.; Clothier, B.E.

    2000-02-01

    Time domain reflectometry (TDR) possesses potential for determining solute-transport parameters, such as dispersion coefficients and retardation factors for reactive solutes. The authors developed a simple method based on peak-to-peak measurements of water and solute velocities through the soil using TDR. The method was tested by carrying out unsaturated leaching experiments in the laboratory on two soil columns packed with a South Pacific soil from Mare, which is a ferrasol with variable surface charge. One column was left bare and the other was planted with mustard. Pulses of CaBr{sub 2} and Ca(NO{sub 3}){minus}{sub 2} were applied to the surface of eithermore » wet or dry soil and then leached by water from a rainfall simulator applied at a steady rate of between 30 and 45 mm h{sup {minus}1}. Water and solute transport were monitored by collecting the effluent. Contemporaneous in situ measurements of the water content and electrical conductivity were made using TDR. Transport parameters for the convection-dispersion equation, with a linear adsorption isotherm, were obtained from the flux concentration and the solute resident concentrations measured by TDR. Anion retardations between 1.2 and 1.7, and dispersivities between 1 and 9 mm, were found. Retardations also were calculated using the authors simple approach based on TDR-measured water and solute front velocities. These used TDR measurements of soil water content and bulk soil electrical conductivity with time, and were similar to those obtained from the effluent. The agreement suggests TDR could be a valuable in situ technique for obtaining the parameters relating to reactive solute transport through soil.« less

  4. Imaging Characteristics in ALK Fusion-Positive Lung Adenocarcinomas by Using HRCT

    PubMed Central

    Okumura, Sakae; Kuroda, Hiroaki; Uehara, Hirofumi; Mun, Mingyon; Takeuchi, Kengo; Nakagawa, Ken

    2014-01-01

    Objectives: We aimed to identify high-resolution computed tomography (HRCT) features useful to distinguish the anaplastic lymphoma kinase gene (ALK) fusion-positive and negative lung adenocarcinomas. Methods: We included 236 surgically resected adenocarcinoma lesions, which included 27 consecutive ALK fusion-positive (AP) lesions, 115 epidermal growth factor receptor mutation-positive lesions, and 94 double-negative lesions. HRCT parameters including size, air bronchograms, pleural indentation, spiculation, and tumor disappearance rate (TDR) were compared. In addition, prevalence of small lesions (≤20 mm) and solid lesions (TDR ≤20%) were compared. Results: AP lesions were significantly smaller and had lower TDR (%) than ALK fusion-negative (AN) lesions (tumor diameter: 20.7 mm ± 14.1 mm vs. 27.4 mm ± 13.8 mm, respectively, p <0.01; TDR: 22.8% ± 24.8% vs. 44.8% ± 33.2%, respectively, p <0.01). All AP lesions >20 mm (n = 7, 25.9%) showed a solid pattern. Among all small lesions, AP lesions had lower TDR and more frequent spiculation than AN lesions (p <0.01). Among solid lesions, AP lesions were smaller than AN lesions (p = 0.01). Conclusion: AP lung lesions were significantly smaller and had a lower TDR than AN lesions. Spiculation was more frequent in small lesions. Non-solid >20 mm lesions may be ALK fusion-negative. PMID:24899136

  5. Development of injectable hydrogels for nucleus pulposus replacement

    NASA Astrophysics Data System (ADS)

    Thomas, Jonathan D.

    Intervertebral disc degeneration has been reported as the underlying cause for 75% of cases of lower back pain and is marked by dehydration of the nucleus pulposus within the intervertebral disc. There have been many implant designs to replace the nucleus pulposus. Some researchers have proposed the replacement of the nucleus pulposus with hydrogel materials. The insertion of devices made from these materials further compromises the annulus of the disc. An ideal nucleus replacement could be injected into the disc space and form a solid in vivo. However, injectable replacements using curing elastomers and thermoplastic materials are not ideal because of the potentially harmful exothermic heat evolved from their reactions and the toxicity of the reactants used. We propose a hydrogel system that can be injected as a liquid at 25°C and solidified to yield a hydrogel within the intervertebral disc at 37°C. In aqueous solutions, these polymers have Lower Critical Solution Temperatures (LCST) between 25-37°C, making them unique candidate materials for this application. Poly(N-isopropylacrylamide) (PNIPAAm) is the most widely studied LCST polymer due to its drastic transition near body temperature. However, by itself, pure PNIPAAm forms a hydrogel that has low water content and can readily undergo plastic deformation. To increase the water content and impart elasticity to PNIPAAm hydrogels, grafted and branched hydrogel systems were created that incorporated the thermogelling PNIPAAm and hydrophilic poly(ethylene glycol) (PEG). In this research, the effects of polymer composition and monomer to initiator ratio, which controls polymer MW, on the in vitro swelling properties (mass, chemical, and compressive mechanical stability) of hydrogels formed from aqueous solutions of these polymers were evaluated. Immersion studies were also conducted in solutions to simulate the osmotic environment of the nucleus pulposus. The effects of repeated compression and unloading cycles on the water content and dimensional recovery of hydrogels made from three candidate polymer formulations were also determined. Unlike PNIPAAm and PEG grafted PNIPAAm hydrogels, PEG branched hydrogels have covalently linked networks. Addition of 7 mol% PEG branches to PNIPAAm resulted in a hydrogel with a higher water content and better elastic recovery than hydrogels made from pure PNIPAAm. PEG branched PNIPAAm hydrogels were shown to have mass, chemical, and compressive mechanical stability in vitro. Furthermore, these hydrogels showed superior dimensional recovery after compressive cycling than pure PNIPAAm and PEG grafted PNIPAAm hydrogels. The 7 mol% PEG branched PNIPAAm hydrogels have suitable swelling and mechanical properties to potentially serve as a nucleus pulposus replacement.

  6. Sagittal endplate morphology of the lower lumbar spine.

    PubMed

    Lakshmanan, Palaniappan; Purushothaman, Balaji; Dvorak, Vlasta; Schratt, Walter; Thambiraj, Sathya; Boszczyk, Maximilian

    2012-05-01

    The sagittal profile of lumbar endplates is discrepant from current simplified disc replacement and fusion device design. Endplate concavity is symmetrical in the coronal plane but shows considerable variability in the sagittal plane, which may lead to implant-endplate mismatch. The aim of this investigation is to provide further analysis of the sagittal endplate morphology of the mid to lower lumbar spine study (L3–S1), thereby identifying the presence of common endplate shape patterns across these levels and providing morphological reference values complementing the findings of previous studies. Observational study. A total of 174 magnetic resonance imaging (MRI) scans of the adult lumbar spine from the digital archive of our centre, which met the inclusion criteria, were studied. Superior (SEP) and inferior (IEP) endplate shape was divided into flat (no concavity), oblong (homogeneous concavity) and ex-centric (inhomogeneous concavity). The concavity depth (ECD) and location of concavity apex (ECA) relative to endplate diameter of the vertebrae L3–S1 were determined. Flat endplates were only predominant at the sacrum SEP (84.5%). The L5 SEP was flat in 24.7% and all other endplates in less than 10%. The majority of endplates were concave with a clear trend of endplate shape becoming more ex-centric from L3 IEP (56.9% oblong vs. 37.4% ex-centric) to L5 IEP (4% oblong vs. 94.3% ex-centric). Ex-centric ECA were always found in the posterior half of the lumbar endplates. Both the oblong and ex-centric ECD was 2-3 mm on average with the IEP of a motion segment regularly possessing the greater depth. A sex- or age-related difference could not be found. The majority of lumbar endplates are concave, while the majority of sacral endplates are flat. An oblong and an ex-centric endplate shape can be distinguished, whereby the latter is more common at the lower lumbar levels. The apex of the concavity of ex-centric discs is located in the posterior half of the endplate and the concavity of the inferior endplate is deeper than that of the superior endplate. Based on the above, the current TDR and ALIF implant design does not sufficiently match the morphology of lumbar endplates in the sagittal plane.

  7. Disc erosion in Models 103 and 104 of Beall mitral valve prostheses

    PubMed Central

    Gómez, Ricardo; Verduras, María José; Lopez-Quintana, Alfonso; Riera, Luis; Zerolo, Ignacio; Martinez-Bordiu, Cristóbal

    1981-01-01

    Three cases of severe disc variance and erosion of the Teflon-disc Beall mitral valve prosthesis (Models 103 and 104) are reported. In two patients, the Beall mitral valves were excised and replaced with two Björk-Shiley mitral valves. The remaining patient did not survive, and at autopsy, the lens was found at the aortic bifurcation level. Because of this potentially lethal complication, careful follow-up of patients with Beall mitral valve prostheses (Models 103 and 104) is recommended. Images PMID:15216211

  8. Infiltration and solute transport experiments in unsaturated sand and gravel, Cape Cod, Massachusetts: Experimental design and overview of results

    USGS Publications Warehouse

    Rudolph, David L.; Kachanoski , R. Gary; Celia, Michael A.; LeBlanc, Denis R.; Stevens, Jonathon H.

    1996-01-01

    A series of infiltration and tracer experiments was conducted in unsaturated sand and gravel deposits on Cape Cod, Massachusetts. A network of 112 porous cup lysimeters and 168 time domain reflectometry (TDR) probes was deployed at depths from 0.25 to 2.0 m below ground surface along the centerline of a 2-m by 10-m test plot. The test plot was irrigated at rates ranging from 7.9 to 37.0 cm h−1 through a sprinkler system. Transient and steady state water content distributions were monitored with the TDR probes and spatial properties of water content distributions were determined from the TDR data. The spatial variance of the water content tended to increase as the average water content increased. In addition, estimated horizontal correlation length scales for water content were significantly smaller than those estimated by previous investigators for saturated hydraulic conductivity. Under steady state flow conditions at each irrigation rate, a sodium chloride solution was released as a tracer at ground surface and tracked with both the lysimeter and TDR networks. Transect-averaged breakthrough curves at each monitoring depth were constructed both from solute concentrations measured in the water samples and flux concentrations inferred from the TDR measurements. Transport properties, including apparent solute velocities, dispersion coefficients, and total mass balances, were determined independently from both sets of breakthrough curves. The dispersion coefficients tended to increase with depth, reaching a constant value with the lysimeter data and appearing to increase continually with the TDR data. The variations with depth of the solute transport parameters, along with observations of water and solute mass balance and spatial distributions of water content, provide evidence of significant three-dimensional flow during the irrigation experiments. The TDR methods are shown to efficiently provide dense spatial and temporal data sets for both flow and solute transport in unsaturated sediments with minimal sediment and flow field disturbance. Combined implementation of lysimeters and TDR probes can enhance data interpretation particularly when three-dimensional flow conditions are anticipated.

  9. Simultaneous measurement of unfrozen water content and ice content in frozen soil using gamma ray attenuation and TDR

    NASA Astrophysics Data System (ADS)

    Zhou, Xiaohai; Zhou, Jian; Kinzelbach, Wolfgang; Stauffer, Fritz

    2014-12-01

    The freezing temperature of water in soil is not constant but varies over a range determined by soil texture. Consequently, the amounts of unfrozen water and ice change with temperature in frozen soil, which in turn affects hydraulic, thermal, and mechanical properties of frozen soil. In this paper, an Am-241 gamma ray source and time-domain reflectometry (TDR) were combined to measure unfrozen water content and ice content in frozen soil simultaneously. The gamma ray attenuation was used to determine total water content. The TDR was used to determine the dielectric constant of the frozen soil. Based on a four-phase mixing model, the amount of unfrozen water content in the frozen soil could be determined. The ice content was inferred by the difference between total water content and unfrozen water content. The gamma ray attenuation and the TDR were both calibrated by a gravimetric method. Water contents measured by gamma ray attenuation and TDR in an unfrozen silt column under infiltration were compared and showed that the two methods have the same accuracy and response to changes of water content. Unidirectional column freezing experiments were performed to apply the combined method of gamma ray attenuation and TDR for measuring unfrozen water content and ice content. The measurement error of the gamma ray attenuation and TDR was around 0.02 and 0.01 m3/m3, respectively. The overestimation of unfrozen water in frozen soil by TDR alone was quantified and found to depend on the amount of ice content. The higher the ice content, the larger the overestimation. The study confirmed that the combined method could accurately determine unfrozen water content and ice content in frozen soil. The results of soil column freezing experiments indicate that total water content distribution is affected by available pore space and the freezing front advance rate. It was found that there is similarity between the soil water characteristic and the soil freezing characteristic of variably saturated soil. Unfrozen water content is independent of total water content and affected only by temperature when the freezing point is reached.

  10. In vivo performance of an acellular disc-like angle ply structure (DAPS) for total disc replacement in a small animal model.

    PubMed

    Martin, John T; Kim, Dong Hwa; Milby, Andrew H; Pfeifer, Christian G; Smith, Lachlan J; Elliott, Dawn M; Smith, Harvey E; Mauck, Robert L

    2017-01-01

    Total intervertebral disc replacement with a biologic engineered disc may be an alternative to spinal fusion for treating end-stage disc disease. In previous work, we developed disc-like angle ply structures (DAPS) that replicate the structure and function of the native disc and a rat tail model to evaluate DAPS in vivo. Here, we evaluated a strategy in which, after in vivo implantation, endogenous cells could colonize the acellular DAPS and form an extracellular matrix organized by the DAPS topographical template. To do so, acellular DAPS were implanted into the caudal spines of rats and evaluated over 12 weeks by mechanical testing, histology, and microcomputed tomography. An external fixation device was used to stabilize the implant site and various control groups were included to evaluate the effect of immobilization. There was robust tissue formation within the DAPS after implantation and compressive mechanical properties of the implant matched that of the native motion segment. Immobilization provided a stable site for fibrous tissue formation after either a discectomy or a DAPS implantation, but bony fusion eventually resulted, with segments showing intervertebral bridging after long-term implantation, a process that was accelerated by the implanted DAPS. Thus, while compressive mechanical properties were replicated after DAPS implantation, methods to actively prevent fusion must be developed. Future work will focus on limiting fusion by remobilizing the motion segment after a period of integration, delivering pro-chondrogenic factors, and pre-seeding DAPS with cells prior to implantation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:23-31, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Geographic and temporal trends in the molecular epidemiology and genetic mechanisms of transmitted HIV-1 drug resistance: an individual-patient- and sequence-level meta-analysis.

    PubMed

    Rhee, Soo-Yon; Blanco, Jose Luis; Jordan, Michael R; Taylor, Jonathan; Lemey, Philippe; Varghese, Vici; Hamers, Raph L; Bertagnolio, Silvia; Rinke de Wit, Tobias F; Aghokeng, Avelin F; Albert, Jan; Avi, Radko; Avila-Rios, Santiago; Bessong, Pascal O; Brooks, James I; Boucher, Charles A B; Brumme, Zabrina L; Busch, Michael P; Bussmann, Hermann; Chaix, Marie-Laure; Chin, Bum Sik; D'Aquin, Toni T; De Gascun, Cillian F; Derache, Anne; Descamps, Diane; Deshpande, Alaka K; Djoko, Cyrille F; Eshleman, Susan H; Fleury, Herve; Frange, Pierre; Fujisaki, Seiichiro; Harrigan, P Richard; Hattori, Junko; Holguin, Africa; Hunt, Gillian M; Ichimura, Hiroshi; Kaleebu, Pontiano; Katzenstein, David; Kiertiburanakul, Sasisopin; Kim, Jerome H; Kim, Sung Soon; Li, Yanpeng; Lutsar, Irja; Morris, Lynn; Ndembi, Nicaise; Ng, Kee Peng; Paranjape, Ramesh S; Peeters, Martine; Poljak, Mario; Price, Matt A; Ragonnet-Cronin, Manon L; Reyes-Terán, Gustavo; Rolland, Morgane; Sirivichayakul, Sunee; Smith, Davey M; Soares, Marcelo A; Soriano, Vincent V; Ssemwanga, Deogratius; Stanojevic, Maja; Stefani, Mariane A; Sugiura, Wataru; Sungkanuparph, Somnuek; Tanuri, Amilcar; Tee, Kok Keng; Truong, Hong-Ha M; van de Vijver, David A M C; Vidal, Nicole; Yang, Chunfu; Yang, Rongge; Yebra, Gonzalo; Ioannidis, John P A; Vandamme, Anne-Mieke; Shafer, Robert W

    2015-04-01

    Regional and subtype-specific mutational patterns of HIV-1 transmitted drug resistance (TDR) are essential for informing first-line antiretroviral (ARV) therapy guidelines and designing diagnostic assays for use in regions where standard genotypic resistance testing is not affordable. We sought to understand the molecular epidemiology of TDR and to identify the HIV-1 drug-resistance mutations responsible for TDR in different regions and virus subtypes. We reviewed all GenBank submissions of HIV-1 reverse transcriptase sequences with or without protease and identified 287 studies published between March 1, 2000, and December 31, 2013, with more than 25 recently or chronically infected ARV-naïve individuals. These studies comprised 50,870 individuals from 111 countries. Each set of study sequences was analyzed for phylogenetic clustering and the presence of 93 surveillance drug-resistance mutations (SDRMs). The median overall TDR prevalence in sub-Saharan Africa (SSA), south/southeast Asia (SSEA), upper-income Asian countries, Latin America/Caribbean, Europe, and North America was 2.8%, 2.9%, 5.6%, 7.6%, 9.4%, and 11.5%, respectively. In SSA, there was a yearly 1.09-fold (95% CI: 1.05-1.14) increase in odds of TDR since national ARV scale-up attributable to an increase in non-nucleoside reverse transcriptase inhibitor (NNRTI) resistance. The odds of NNRTI-associated TDR also increased in Latin America/Caribbean (odds ratio [OR] = 1.16; 95% CI: 1.06-1.25), North America (OR = 1.19; 95% CI: 1.12-1.26), Europe (OR = 1.07; 95% CI: 1.01-1.13), and upper-income Asian countries (OR = 1.33; 95% CI: 1.12-1.55). In SSEA, there was no significant change in the odds of TDR since national ARV scale-up (OR = 0.97; 95% CI: 0.92-1.02). An analysis limited to sequences with mixtures at less than 0.5% of their nucleotide positions—a proxy for recent infection—yielded trends comparable to those obtained using the complete dataset. Four NNRTI SDRMs—K101E, K103N, Y181C, and G190A—accounted for >80% of NNRTI-associated TDR in all regions and subtypes. Sixteen nucleoside reverse transcriptase inhibitor (NRTI) SDRMs accounted for >69% of NRTI-associated TDR in all regions and subtypes. In SSA and SSEA, 89% of NNRTI SDRMs were associated with high-level resistance to nevirapine or efavirenz, whereas only 27% of NRTI SDRMs were associated with high-level resistance to zidovudine, lamivudine, tenofovir, or abacavir. Of 763 viruses with TDR in SSA and SSEA, 725 (95%) were genetically dissimilar; 38 (5%) formed 19 sequence pairs. Inherent limitations of this study are that some cohorts may not represent the broader regional population and that studies were heterogeneous with respect to duration of infection prior to sampling. Most TDR strains in SSA and SSEA arose independently, suggesting that ARV regimens with a high genetic barrier to resistance combined with improved patient adherence may mitigate TDR increases by reducing the generation of new ARV-resistant strains. A small number of NNRTI-resistance mutations were responsible for most cases of high-level resistance, suggesting that inexpensive point-mutation assays to detect these mutations may be useful for pre-therapy screening in regions with high levels of TDR. In the context of a public health approach to ARV therapy, a reliable point-of-care genotypic resistance test could identify which patients should receive standard first-line therapy and which should receive a protease-inhibitor-containing regimen.

  12. Geographic and Temporal Trends in the Molecular Epidemiology and Genetic Mechanisms of Transmitted HIV-1 Drug Resistance: An Individual-Patient- and Sequence-Level Meta-Analysis

    PubMed Central

    Rhee, Soo-Yon; Blanco, Jose Luis; Jordan, Michael R.; Taylor, Jonathan; Lemey, Philippe; Varghese, Vici; Hamers, Raph L.; Bertagnolio, Silvia; de Wit, Tobias F. Rinke; Aghokeng, Avelin F.; Albert, Jan; Avi, Radko; Avila-Rios, Santiago; Bessong, Pascal O.; Brooks, James I.; Boucher, Charles A. B.; Brumme, Zabrina L.; Busch, Michael P.; Bussmann, Hermann; Chaix, Marie-Laure; Chin, Bum Sik; D’Aquin, Toni T.; De Gascun, Cillian F.; Derache, Anne; Descamps, Diane; Deshpande, Alaka K.; Djoko, Cyrille F.; Eshleman, Susan H.; Fleury, Herve; Frange, Pierre; Fujisaki, Seiichiro; Harrigan, P. Richard; Hattori, Junko; Holguin, Africa; Hunt, Gillian M.; Ichimura, Hiroshi; Kaleebu, Pontiano; Katzenstein, David; Kiertiburanakul, Sasisopin; Kim, Jerome H.; Kim, Sung Soon; Li, Yanpeng; Lutsar, Irja; Morris, Lynn; Ndembi, Nicaise; NG, Kee Peng; Paranjape, Ramesh S.; Peeters, Martine; Poljak, Mario; Price, Matt A.; Ragonnet-Cronin, Manon L.; Reyes-Terán, Gustavo; Rolland, Morgane; Sirivichayakul, Sunee; Smith, Davey M.; Soares, Marcelo A.; Soriano, Vincent V.; Ssemwanga, Deogratius; Stanojevic, Maja; Stefani, Mariane A.; Sugiura, Wataru; Sungkanuparph, Somnuek; Tanuri, Amilcar; Tee, Kok Keng; Truong, Hong-Ha M.; van de Vijver, David A. M. C.; Vidal, Nicole; Yang, Chunfu; Yang, Rongge; Yebra, Gonzalo; Ioannidis, John P. A.; Vandamme, Anne-Mieke; Shafer, Robert W.

    2015-01-01

    Background Regional and subtype-specific mutational patterns of HIV-1 transmitted drug resistance (TDR) are essential for informing first-line antiretroviral (ARV) therapy guidelines and designing diagnostic assays for use in regions where standard genotypic resistance testing is not affordable. We sought to understand the molecular epidemiology of TDR and to identify the HIV-1 drug-resistance mutations responsible for TDR in different regions and virus subtypes. Methods and Findings We reviewed all GenBank submissions of HIV-1 reverse transcriptase sequences with or without protease and identified 287 studies published between March 1, 2000, and December 31, 2013, with more than 25 recently or chronically infected ARV-naïve individuals. These studies comprised 50,870 individuals from 111 countries. Each set of study sequences was analyzed for phylogenetic clustering and the presence of 93 surveillance drug-resistance mutations (SDRMs). The median overall TDR prevalence in sub-Saharan Africa (SSA), south/southeast Asia (SSEA), upper-income Asian countries, Latin America/Caribbean, Europe, and North America was 2.8%, 2.9%, 5.6%, 7.6%, 9.4%, and 11.5%, respectively. In SSA, there was a yearly 1.09-fold (95% CI: 1.05–1.14) increase in odds of TDR since national ARV scale-up attributable to an increase in non-nucleoside reverse transcriptase inhibitor (NNRTI) resistance. The odds of NNRTI-associated TDR also increased in Latin America/Caribbean (odds ratio [OR] = 1.16; 95% CI: 1.06–1.25), North America (OR = 1.19; 95% CI: 1.12–1.26), Europe (OR = 1.07; 95% CI: 1.01–1.13), and upper-income Asian countries (OR = 1.33; 95% CI: 1.12–1.55). In SSEA, there was no significant change in the odds of TDR since national ARV scale-up (OR = 0.97; 95% CI: 0.92–1.02). An analysis limited to sequences with mixtures at less than 0.5% of their nucleotide positions—a proxy for recent infection—yielded trends comparable to those obtained using the complete dataset. Four NNRTI SDRMs—K101E, K103N, Y181C, and G190A—accounted for >80% of NNRTI-associated TDR in all regions and subtypes. Sixteen nucleoside reverse transcriptase inhibitor (NRTI) SDRMs accounted for >69% of NRTI-associated TDR in all regions and subtypes. In SSA and SSEA, 89% of NNRTI SDRMs were associated with high-level resistance to nevirapine or efavirenz, whereas only 27% of NRTI SDRMs were associated with high-level resistance to zidovudine, lamivudine, tenofovir, or abacavir. Of 763 viruses with TDR in SSA and SSEA, 725 (95%) were genetically dissimilar; 38 (5%) formed 19 sequence pairs. Inherent limitations of this study are that some cohorts may not represent the broader regional population and that studies were heterogeneous with respect to duration of infection prior to sampling. Conclusions Most TDR strains in SSA and SSEA arose independently, suggesting that ARV regimens with a high genetic barrier to resistance combined with improved patient adherence may mitigate TDR increases by reducing the generation of new ARV-resistant strains. A small number of NNRTI-resistance mutations were responsible for most cases of high-level resistance, suggesting that inexpensive point-mutation assays to detect these mutations may be useful for pre-therapy screening in regions with high levels of TDR. In the context of a public health approach to ARV therapy, a reliable point-of-care genotypic resistance test could identify which patients should receive standard first-line therapy and which should receive a protease-inhibitor-containing regimen. PMID:25849352

  13. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    PubMed

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  14. What is the correlation of in vivo wear and damage patterns with in vitro TDR motion response?

    PubMed Central

    Kurtz, Steven M.; Patwardhan, Avinash; MacDonald, Daniel; Ciccarelli, Lauren; van Ooij, André; Lorenz, Mark; Zindrick, Michael; O’Leary, Patrick; Isaza, Jorge; Ross, Raymond

    2008-01-01

    Background Context Total disc replacements (TDRs) have been used to reduce pain and preserve motion. However, the comparison of polyethylene wear following long-term implantation to those tested using an in vitro model had not yet been investigated. Purpose The purpose of this study was to correlate wear and damage patterns in retrieved TDRs with motion patterns observed in a clinically validated in vitro lumbar spine model. We also sought to determine whether one-sided wear and motion patterns were associated with greater in vivo wear. Study Design This two-part study combined the evaluation of retrieved total disc replacements with a biomechanical study using human lumbar spines. Patient Sample 38 CHARITÉ lumbar artificial discs were retrieved from 32 patients (24 female, 75%) after 7.3 years average implantation (range: 1.8 to 16.1y). The components were implanted at L2/L3 (n=1), L3/L4 (n=2), L4/L5 (n=20), and L5/S1 (n=15). All the implants were removed due to intractable back pain and/or facet degeneration. In addition, they were removed due to subsidence (n=10), anterior migration (n=3), core dislocation (n=2), lateral subluxation (n=1), endplate loosening (n = 2), and osteolysis (n=1). In parallel, 7 new implants were evaluated at L4-L5 and 13 implants at L5-S1 in an in vitro lumbar spine model. Outcome Measures Retrieval analysis included evaluation of clinical data, dimensional measurements and assessment of the extent and severity of PE surface damage mechanisms. In vitro testing involved the observation of motion patterns during physiological loading. Methods For the retrievals, each side of the PE core was independently analyzed at the rim and dome for the presence of machining marks, wear, and fracture. 35 cores were further analyzed using MicroCT to determine whether the wear was one-sided, or symmetrically distributed. For the in vitro study the new implants were tested under physiologic loads (flexion-extension with a compressive follower preload) using a validated cadaveric lumbar spine model. The center of the prosthesis was 2 mm posterior to the mid-point of the vertebral body endplate in mid-sagittal plane. Motion patterns of the in vitro-tested implants were tracked using sequential video-flouroscopy. Results Substantial variability was observed in the wear patterns of the retrievals. 15/35 retrieved cores (43%) displayed one-sided wear patterns. The median dome penetration was 0.2 mm (range: 0.06 to 0.9 mm) and the median penetration rate was 0.04 mm/y (range: 0.01 to 0.2 mm/y). No significant difference in penetration or penetration rate was observed between retrievals with one-sided and symmetric wear patterns (p >0.05). Significant correlations were observed between implantation time and penetration (rho = 0.46, p = 0.004) and penetration rate (rho = −0.48, p = 0.003). In the in vitro study, there was clear visual evidence of motion at both articulations in 8/20 implantations. In additional 8/20 cases, there was some evidence of motion at both articulations; however, the predominant motion occurred at the top articulation. In 4/20 implantations motion could be visually detected only at the top articulation. Core entrapment and pinching was observed in 7/20 cases as the segment was extended, and was associated with visual evidence of core bending or deformation in 5/20 cases. PMID:18317190

  15. An anther development F-box (ADF) protein regulated by tapetum degeneration retardation (TDR) controls rice anther development.

    PubMed

    Li, Li; Li, Yixing; Song, Shufeng; Deng, Huafeng; Li, Na; Fu, Xiqin; Chen, Guanghui; Yuan, Longping

    2015-01-01

    In this study, we reported that a F-box protein, OsADF, as one of the direct targets of TDR , plays a critical role in rice tapetum cell development and pollen formation. The tapetum, the innermost sporophytic tissue of anther, plays an important supportive role in male reproduction in flowering plants. After meiosis, tapetal cells undergo programmed cell death (PCD) and provide nutrients for pollen development. Previously we showed that tapetum degeneration retardation (TDR), a basic helix-loop-helix transcription factor, can trigger tapetal PCD and control pollen wall development during anther development. However, the comprehensive regulatory network of TDR remains to be investigated. In this study, we cloned and characterized a panicle-specific expression F-box protein, anther development F-box (OsADF). By qRT-PCR and RNA in situ hybridization, we further confirmed that OsADF expressed specially in tapetal cells from stage 9 to stage 12 during anther development. In consistent with this specific expression pattern, the RNAi transgenic lines of OsADF exhibited abnormal tapetal degeneration and aborted microspores development, which eventually grew pollens with reduced fertility. Furthermore, we demonstrated that the TDR, a key regulator in controlling rice anther development, could regulate directly the expression of OsADF by binding to E-box motifs of its promoter. Therefore, this work highlighted the possible regulatory role of TDR, which regulates tapetal cell development and pollen formation via triggering the possible ADF-mediated proteolysis pathway.

  16. Monitoring stream stage, channel profile, and aqueous conductivity with time domain reflectometry (TDR).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brainard, James Robert; Tidwell, Vincent Carroll; Coplen, Amy K.

    2004-11-01

    Time domain reflectometry (TDR) operates by propagating a radar frequency electromagnetic pulse down a transmission line while monitoring the reflected signal. As the electromagnetic pulse propagates along the transmission line, it is subject to impedance by the dielectric properties of the media along the transmission line (e.g., air, water, sediment), reflection at dielectric discontinuities (e.g., air-water or water-sediment interface), and attenuation by electrically conductive materials (e.g., salts, clays). Taken together, these characteristics provide a basis for integrated stream monitoring; specifically, concurrent measurement of stream stage, channel profile and aqueous conductivity. Here, we make novel application of TDR within the contextmore » of stream monitoring. Efforts toward this goal followed three critical phases. First, a means of extracting the desired stream parameters from measured TDR traces was required. Analysis was complicated by the fact that interface location and aqueous conductivity vary concurrently and multiple interfaces may be present at any time. For this reason a physically based multisection model employing the S11 scatter function and Cole-Cole parameters for dielectric dispersion and loss was developed to analyze acquired TDR traces. Second, we explored the capability of this multisection modeling approach for interpreting TDR data acquired from complex environments, such as encountered in stream monitoring. A series of laboratory tank experiments were performed in which the depth of water, depth of sediment, and conductivity were varied systematically. Comparisons between modeled and independently measured data indicate that TDR measurements can be made with an accuracy of {+-}3.4x10{sup -3} m for sensing the location of an air/water or water/sediment interface and {+-}7.4% of actual for the aqueous conductivity. Third, monitoring stations were sited on the Rio Grande and Paria rivers to evaluate performance of the TDR system under normal field conditions. At the Rio Grande site (near Central Bridge in Albuquerque, New Mexico) continuous monitoring of stream stage and aqueous conductivity was performed for 6 months. Additionally, channel profile measurements were acquired at 7 locations across the river. At the Paria site (near Lee's Ferry, Arizona) stream stage and aqueous conductivity data were collected over a 4-month period. Comparisons drawn between our TDR measurements and USGS gage data indicate that the stream stage is accurate within {+-}0.88 cm, conductivity is accurate within {+-}11% of actual, and channel profile measurements agree within {+-}1.2 cm.« less

  17. Transformation diffusion reconstruction of three-dimensional histology volumes from two-dimensional image stacks.

    PubMed

    Casero, Ramón; Siedlecka, Urszula; Jones, Elizabeth S; Gruscheski, Lena; Gibb, Matthew; Schneider, Jürgen E; Kohl, Peter; Grau, Vicente

    2017-05-01

    Traditional histology is the gold standard for tissue studies, but it is intrinsically reliant on two-dimensional (2D) images. Study of volumetric tissue samples such as whole hearts produces a stack of misaligned and distorted 2D images that need to be reconstructed to recover a congruent volume with the original sample's shape. In this paper, we develop a mathematical framework called Transformation Diffusion (TD) for stack alignment refinement as a solution to the heat diffusion equation. This general framework does not require contour segmentation, is independent of the registration method used, and is trivially parallelizable. After the first stack sweep, we also replace registration operations by operations in the space of transformations, several orders of magnitude faster and less memory-consuming. Implementing TD with operations in the space of transformations produces our Transformation Diffusion Reconstruction (TDR) algorithm, applicable to general transformations that are closed under inversion and composition. In particular, we provide formulas for translation and affine transformations. We also propose an Approximated TDR (ATDR) algorithm that extends the same principles to tensor-product B-spline transformations. Using TDR and ATDR, we reconstruct a full mouse heart at pixel size 0.92µm×0.92µm, cut 10µm thick, spaced 20µm (84G). Our algorithms employ only local information from transformations between neighboring slices, but the TD framework allows theoretical analysis of the refinement as applying a global Gaussian low-pass filter to the unknown stack misalignments. We also show that reconstruction without an external reference produces large shape artifacts in a cardiac specimen while still optimizing slice-to-slice alignment. To overcome this problem, we use a pre-cutting blockface imaging process previously developed by our group that takes advantage of Brewster's angle and a polarizer to capture the outline of only the topmost layer of wax in the block containing embedded tissue for histological sectioning. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Total disc replacement using a tissue-engineered intervertebral disc in vivo: new animal model and initial results

    PubMed Central

    Gebhard, Harry; Bowles, Robby; Dyke, Jonathan; Saleh, Tatianna; Doty, Stephen; Bonassar, Lawrence; Härtl, Roger

    2010-01-01

    Study type: Basic science Introduction: Chronic back pain due to degenerative disc disease (DDD) is among the most important medical conditions causing morbidity and significant health care costs. Surgical treatment options include disc replacement or fusion surgery, but are associated with significant short- and long-term risks.1 Biological tissue-engineering of human intervertebral discs (IVD) could offer an important alternative.2 Recent in vitro data from our group have shown successful engineering and growth of ovine intervertebral disc composites with circumferentially aligned collagen fibrils in the annulus fibrosus (AF) (Figure 1).3 Figure 1 Tissue-engineered composite disc a Experimental steps to generate composite tissue-engineered IVDs3 b Example of different AF formulations on collagen alignment in the AF. Second harmonic generation and two-photon excited fluorescence images of seeded collagen gels (for AF) of 1 and 2.5 mg/ml over time. At seeding, cells and collagen were homogenously distributed in the gels. Over time, AF cells elongated and collagen aligned parallel to cells. Less contraction and less alignment is noted after 3 days in the 2.5 mg/mL gel. c Imaging-based creation of a virtual disc model that will serve as template for the engineered disc. Total disc dimensions (AF and NP) were retrieved from micro-computer tomography (CT) (left images), and nucleus pulposus (NP) dimensions alone were retrieved from T2-weighted MRI images (right images). Merging of MRI and micro-CT models revealed a composite disc model (middle image)—Software: Microview, GE Healthcare Inc., Princeton, NJ; and slicOmatic v4.3, TomoVision, Montreal, Canada. d Flow chart describing the process for generating multi-lamellar tissue engineered IVDs. IVDs are produced by allowing cell-seeded collagen layers to contract around a cell-seeded alginate core (NP) over time Objective: The next step is to investigate if biological disc implants survive, integrate, and restore function to the spine in vivo. A model will be developed that allows efficient in vivo testing of tissue-engineered discs of various compositions and characteristics. Methods: Athymic rats were anesthetized and a dorsal approach was chosen to perform a microsurgical discectomy in the rat caudal spine (Fig. 2,Fig. 3). Control group I (n = 6) underwent discectomy only, Control group II (n = 6) underwent discectomy, followed by reimplantation of the autologous disc. Two treatment groups (group III, n = 6, 1 month survival; group IV, n = 6, 6 months survival) received a tissue-engineered composite disc implant. The rodents were followed clinically for signs of infection, pain level and wound healing. X-rays and magnetic resonance imaging (MRI) were assessed postoperatively and up to 6 months after surgery (Fig. 6,Fig. 7). A 7 Tesla MRI (Bruker) was implemented for assessment of the operated level as well as the adjacent disc (hydration). T2-weighted sequences were interpreted by a semiquantitative score (0 = no signal, 1 = weak signal, 2 = strong signal and anatomical features of a normal disc). Histology was performed with staining for proteoglycans (Alcian blue) and collagen (Picrosirius red) (Fig. 4,Fig. 5). Figure 2 Disc replacement surgery a Operative situs with native disc that has been disassociated from both adjacent vertebrae b Native disc (left) and tissue-engineered implant (right) c Implant in situ before wound closureAF: Annulus fi brosus, nP: nucleus pulposus, eP: endplate, M: Muscle, T: Tendon, s: skin, art: artery, GP: Growth plate, B: Bone Figure 3 Disc replacement surgery. Anatomy of the rat caudal disc space a Pircrosirius red stained axial cut of native disc space b Saffranin-O stained sagittal cut of native disc space Figure 4 Histologies of three separate motion segments from three different rats. Animal one = native IVD, Animal two = status after discectomy, Animal three = tissue-engineered implant (1 month) a–c H&E (overall tissue staining for light micrsocopy) d–f Alcian blue (proteoglycans) g–i Picrosirius red (collagen I and II) Figure 5 Histology from one motion segment four months after implantation of a bio-engineered disc construct a Picrosirius red staining (collagen) b Polarized light microscopy showing collagen staining and collagen organization in AF region c Increased Safranin-O staining (proteoglycans) in NP region of the disc implant d Higher magnification of figure 5c: Integration between implanted tissue-engineered total disc replacement and vertebral body bone Figure 6 MRI a Disc space height measurements in flash/T1 sequence (top: implant (714.0 micrometer), bottom: native disc (823.5 micrometer) b T2 sequence, red circle surrounding the implant NP Figure 7 7 Tesla MRI imaging of rat tail IVDs showing axial images (preliminary pilot data) a Diffusion tensor imaging (DTI) on two explanted rat tail discs in Formalin b Higher magnification of a, showing directional alignment of collagen fibers (red and green) when compared to the color ball on top which maps fibers' directional alignment (eg, fibers directing from left to right: red, from top to bottom: blue) c Native IVD in vivo (successful imaging of top and bottom of the IVD (red) d Gradient echo sequence (GE) showing differentiation between NP (light grey) and AF (dark margin) e GE of reimplanted tail IVD at the explantation level f T1Rho sequence demonstrating the NP (grey) within the AF (dark margin), containing the yellow marked region of interest for value acquisition (preliminary data are consistent with values reported in the literature). g T2 image of native IVD in vivo for monitoring of hydration (white: NP) Results: The model allowed reproducible and complete discectomies as well as disc implantation in the rat tail spine without any surgical or postoperative complications. Discectomy resulted in immediate collapse of the disc space. Preliminary results indicate that disc space height was maintained after disc implantation in groups II, III and IV over time. MRI revealed high resolution images of normal intervertebral discs in vivo. Eight out of twelve animals (groups III and IV) showed a positive signal in T2-weighted images after 1 month (grade 0 = 4, grade 1 = 4, grade 2 = 4). Positive staining was seen for collagen as well as proteoglycans at the site of disc implantation after 1 month in each of the six animals with engineered implants (group III). Analysis of group IV showed positive T2 signal in five out of six animals and disc-height preservation in all animals after 6 months. Conclusions: This study demonstrates for the first time that tissue-engineered composite IVDs with circumferentially aligned collagen fibrils survive and integrate with surrounding vertebral bodies when placed in the rat spine for up to 6 months. Tissue-engineered composite IVDs restored function to the rat spine as indicated by maintenance of disc height and vertebral alignment. A significant finding was that maintenance of the composite structure in group III was observed, with increased proteoglycan staining in the nucleus pulposus region (Figure 4d–f). Proteoglycan and collagen matrix as well as disc height preservation and positive T2 signals in MRI are promising parameters and indicate functionality of the implants. PMID:23637671

  19. Total disc replacement using a tissue-engineered intervertebral disc in vivo: new animal model and initial results.

    PubMed

    Gebhard, Harry; Bowles, Robby; Dyke, Jonathan; Saleh, Tatianna; Doty, Stephen; Bonassar, Lawrence; Härtl, Roger

    2010-08-01

     Basic science Introduction:  Chronic back pain due to degenerative disc disease (DDD) is among the most important medical conditions causing morbidity and significant health care costs. Surgical treatment options include disc replacement or fusion surgery, but are associated with significant short- and long-term risks.1 Biological tissue-engineering of human intervertebral discs (IVD) could offer an important alternative.2 Recent in vitro data from our group have shown successful engineering and growth of ovine intervertebral disc composites with circumferentially aligned collagen fibrils in the annulus fibrosus (AF) (Figure 1).3 Figure 1 Tissue-engineered composite disc a Experimental steps to generate composite tissue-engineered IVDs3b Example of different AF formulations on collagen alignment in the AF. Second harmonic generation and two-photon excited fluorescence images of seeded collagen gels (for AF) of 1 and 2.5 mg/ml over time. At seeding, cells and collagen were homogenously distributed in the gels. Over time, AF cells elongated and collagen aligned parallel to cells. Less contraction and less alignment is noted after 3 days in the 2.5 mg/mL gel. c Imaging-based creation of a virtual disc model that will serve as template for the engineered disc. Total disc dimensions (AF and NP) were retrieved from micro-computer tomography (CT) (left images), and nucleus pulposus (NP) dimensions alone were retrieved from T2-weighted MRI images (right images). Merging of MRI and micro-CT models revealed a composite disc model (middle image)-Software: Microview, GE Healthcare Inc., Princeton, NJ; and slicOmatic v4.3, TomoVision, Montreal, Canada. d Flow chart describing the process for generating multi-lamellar tissue engineered IVDs. IVDs are produced by allowing cell-seeded collagen layers to contract around a cell-seeded alginate core (NP) over time Objective:  The next step is to investigate if biological disc implants survive, integrate, and restore function to the spine in vivo. A model will be developed that allows efficient in vivo testing of tissue-engineered discs of various compositions and characteristics.  Athymic rats were anesthetized and a dorsal approach was chosen to perform a microsurgical discectomy in the rat caudal spine (Fig. 2,Fig. 3). Control group I (n = 6) underwent discectomy only, Control group II (n = 6) underwent discectomy, followed by reimplantation of the autologous disc. Two treatment groups (group III, n = 6, 1 month survival; group IV, n = 6, 6 months survival) received a tissue-engineered composite disc implant. The rodents were followed clinically for signs of infection, pain level and wound healing. X-rays and magnetic resonance imaging (MRI) were assessed postoperatively and up to 6 months after surgery (Fig. 6,Fig. 7). A 7 Tesla MRI (Bruker) was implemented for assessment of the operated level as well as the adjacent disc (hydration). T2-weighted sequences were interpreted by a semiquantitative score (0 = no signal, 1 = weak signal, 2 = strong signal and anatomical features of a normal disc). Histology was performed with staining for proteoglycans (Alcian blue) and collagen (Picrosirius red) (Fig. 4,Fig. 5). Figure 2 Disc replacement surgery a Operative situs with native disc that has been disassociated from both adjacent vertebrae b Native disc (left) and tissue-engineered implant (right) c Implant in situ before wound closureAF: Annulus fi brosus, nP: nucleus pulposus, eP: endplate, M: Muscle, T: Tendon, s: skin, art: artery, GP: Growth plate, B: BoneFigure 3 Disc replacement surgery. Anatomy of the rat caudal disc space a Pircrosirius red stained axial cut of native disc space b Saffranin-O stained sagittal cut of native disc spaceFigure 4 Histologies of three separate motion segments from three different rats. Animal one = native IVD, Animal two = status after discectomy, Animal three = tissue-engineered implant (1 month) a-c H&E (overall tissue staining for light micrsocopy) d-f Alcian blue (proteoglycans) g-i Picrosirius red (collagen I and II)Figure 5 Histology from one motion segment four months after implantation of a bio-engineered disc construct a Picrosirius red staining (collagen) b Polarized light microscopy showing collagen staining and collagen organization in AF region c Increased Safranin-O staining (proteoglycans) in NP region of the disc implant d Higher magnification of figure 5c: Integration between implanted tissue-engineered total disc replacement and vertebral body boneFigure 6 MRI a Disc space height measurements in flash/T1 sequence (top: implant (714.0 micrometer), bottom: native disc (823.5 micrometer) b T2 sequence, red circle surrounding the implant NPFigure 7 7 Tesla MRI imaging of rat tail IVDs showing axial images (preliminary pilot data) a Diffusion tensor imaging (DTI) on two explanted rat tail discs in Formalin b Higher magnification of a, showing directional alignment of collagen fibers (red and green) when compared to the color ball on top which maps fibers' directional alignment (eg, fibers directing from left to right: red, from top to bottom: blue) c Native IVD in vivo (successful imaging of top and bottom of the IVD (red) d Gradient echo sequence (GE) showing differentiation between NP (light grey) and AF (dark margin) e GE of reimplanted tail IVD at the explantation level f T1Rho sequence demonstrating the NP (grey) within the AF (dark margin), containing the yellow marked region of interest for value acquisition (preliminary data are consistent with values reported in the literature). g T2 image of native IVD in vivo for monitoring of hydration (white: NP) Results:  The model allowed reproducible and complete discectomies as well as disc implantation in the rat tail spine without any surgical or postoperative complications. Discectomy resulted in immediate collapse of the disc space. Preliminary results indicate that disc space height was maintained after disc implantation in groups II, III and IV over time. MRI revealed high resolution images of normal intervertebral discs in vivo. Eight out of twelve animals (groups III and IV) showed a positive signal in T2-weighted images after 1 month (grade 0 = 4, grade 1 = 4, grade 2 = 4). Positive staining was seen for collagen as well as proteoglycans at the site of disc implantation after 1 month in each of the six animals with engineered implants (group III). Analysis of group IV showed positive T2 signal in five out of six animals and disc-height preservation in all animals after 6 months.  This study demonstrates for the first time that tissue-engineered composite IVDs with circumferentially aligned collagen fibrils survive and integrate with surrounding vertebral bodies when placed in the rat spine for up to 6 months. Tissue-engineered composite IVDs restored function to the rat spine as indicated by maintenance of disc height and vertebral alignment. A significant finding was that maintenance of the composite structure in group III was observed, with increased proteoglycan staining in the nucleus pulposus region (Figure 4d-f). Proteoglycan and collagen matrix as well as disc height preservation and positive T2 signals in MRI are promising parameters and indicate functionality of the implants.

  20. [LOCATION CHANGE OF ROTATION CENTER AFTER SINGLE SEGMENTAL CERVICAL DISC REPLACEMENT WITH ProDisc-C].

    PubMed

    Lou, Jigang; Liu, Hao; Rong, Xin; Gong, Quan; Song, Yueming; Li, Tao

    2015-01-01

    To evaluate the effectiveness of the single segmental cervical disc replacement with ProDisc-C, and to explore the location change of the flexion/extension center of rotation (COR) of the target level as well as its clinical significance. Between June 2010 and February 2012, 23 patients underwent single segmental cervical disc replacement with ProDisc-C, and the clinical data were retrospectively analyzed. Of 23 patients, 9 were male, and 14 were female with the age range from 27 to 65 years (mean, 45 years), and the disease duration ranged from 10 to 84 months (mean, 25 months). There were 15 patients with radiculopathy, 5 patients with myelopathy, and 3 patients with mixed cervical spondylosis. The involved segments were C4,5 in 5 cases, C5,6 in 14 cases, and C6,7 in 4 cases. Japanese Orthopaedic Association (JOA) score and neck disability index (NDI) were adopted to evaluate the effectiveness. Preoperative and Postoperative radiographic parameters, such as cervical overall range of motion (ROM), target segmental ROM, the adjacent segmental ROM, and intervertebral height were compared. Besides, the location changes of the COR of the target level were further analyzed by the alteration of its coordinates (COR-X, COR-Y), and the relationships between the location changes of the COR and the effectiveness or the radiographic results were analyzed. All the operations were completed successfully; 1 case had hoarseness after operation, which disappeared at 3 months after operation. All cases were followed up 18.3 months on average (range, 6-36 months). There was no device migration, loosening, subsidence, or fracture at last follow-up. The JOA score increased significantly and the NDI score decreased significantly at last follow-up when compared with preoperative scores (P < 0.05). No difference was found in the cervical overall ROM, target segmental ROM, the adjacent segmental ROM, and the COR-Y of the target level between pre-operation and last follow-up (P > 0.05); while the intervertebral height and the COR-X increased significantly (P < 0.05). The change of the COR-X had no obvious correlation with the postoperative JOA, NDI, and target segmental ROM (P > 0.05). According to whether the difference of the COR-X between pre- and post-operation was less than the average value 1.86 mm or not, the patients were divided into 2 groups; significant difference was shown in the postoperative target segmental ROM between 2 groups (P < 0.05), but no significant difference was found in the postoperative JOA, NDI, cervical overall ROM, adjacent segmental ROM, and the intervertebral height between 2 groups (P > 0.05). Single segmental cervical disc replacement with ProDisc-C can obtain satisfactory outcomes. The cervical overall ROM, target segmental ROM, and adjacent segmental ROM can be effectively maintained, and the intervertebral height is increased. The location of the flexion/extension COR of the target segment shifts forward after insertion of the ProDisc-C prosthesis, and the postoperative target segmental ROM becomes smaller as the distance of the displacement of the COR becomes greater.

  1. Time domain reflectometry measured moisture content of sewage sludge compost across temperatures.

    PubMed

    Cai, Lu; Chen, Tong-Bin; Gao, Ding; Liu, Hong-Tao; Chen, Jun; Zheng, Guo-Di

    2013-01-01

    Time domain reflectometry (TDR) is a prospective measurement technology for moisture content of sewage sludge composting material; however, a significant dependence upon temperature has been observed. The objective of this study was to assess the impacts of temperature upon moisture content measurement and determine if TDR could be used to monitor moisture content in sewage sludge compost across a range of temperatures. We also investigated the combined effects of temperature and conductivity on moisture content measurement. The results revealed that the moisture content of composting material could be determined by TDR using coated probes, even when the measured material had a moisture content of 0.581 cm(3)cm(-3), temperature of 70°C and conductivity of 4.32 mS cm(-1). TDR probes were calibrated as a function of dielectric properties that included temperature effects. When the bulk temperature varied from 20°C to 70°C, composting material with 0.10-0.70 cm(3)cm(-3) moisture content could be measured by TDR using coated probes, and calibrations based on different temperatures minimized the errors. Copyright © 2012. Published by Elsevier Ltd.

  2. Estimation of Soil-Water Characteristic Curves in Multiple-Cycles Using Membrane and TDR System

    PubMed Central

    Hong, Won-Taek; Jung, Young-Seok; Kang, Seonghun; Lee, Jong-Sub

    2016-01-01

    The objective of this study is to estimate multiple-cycles of the soil-water characteristic curve (SWCC) using an innovative volumetric pressure plate extractor (VPPE), which is incorporated with a membrane and time domain reflectometry (TDR). The pressure cell includes the membrane to reduce the experimental time and the TDR probe to automatically estimate the volumetric water content. For the estimation of SWCC using the VPPE system, four specimens with different grain size and void ratio are prepared. The volumetric water contents of the specimens according to the matric suction are measured by the burette system and are estimated in the TDR system during five cycles of SWCC tests. The volumetric water contents estimated by the TDR system are almost identical to those determined by the burette system. The experimental time significantly decreases with the new VPPE. The hysteresis in the SWCC is largest in the first cycle and is nearly identical after 1.5 cycles. As the initial void ratio decreases, the air entry value increases. This study suggests that the new VPPE may effectively estimate multiple-cycles of the SWCC of unsaturated soils. PMID:28774139

  3. LTPP Computed Parameter: Moisture Content

    DOT National Transportation Integrated Search

    2008-01-01

    A study was conducted to compute in situ soil parameters based on time domain reflectometry (TDR) traces obtained from Long Term Pavement Performance (LTPP) test sections instrumented for the seasonal monitoring program (SMP). Ten TDR sensors were in...

  4. Method and Apparatus for Monitoring the Integrity of a Geomembrane Liner using time Domain Reflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, John L.

    1998-11-09

    Leaks are detected in a multi-layered geomembrane liner by a two-dimensional time domain reflectometry (TDR) technique. The TDR geomembrane liner is constructed with an electrically conductive detection layer positioned between two electrically non-conductive dielectric layers, which are each positioned between the detection layer and an electrically conductive reference layer. The integrity of the TDR geomembrane liner is determined by generating electrical pulses within the detection layer and measuring the time delay for any reflected electrical energy caused by absorption of moisture by a dielectric layer.

  5. Method and apparatus for monitoring the integrity of a geomembrane liner using time domain reflectometry

    DOEpatents

    Morrison, John L [Idaho Falls, ID

    2001-04-24

    Leaks are detected in a multi-layered geomembrane liner by a two-dimensional time domain reflectometry (TDR) technique. The TDR geomembrane liner is constructed with an electrically conductive detection layer positioned between two electrically non-conductive dielectric layers, which are each positioned between the detection layer and an electrically conductive reference layer. The integrity of the TDR geomembrane liner is determined by generating electrical pulses within the detection layer and measuring the time delay for any reflected electrical energy caused by absorption of moisture by a dielectric layer.

  6. Turbulence and turbulent drag reduction in swirling flow: Inertial versus viscous forcing

    NASA Astrophysics Data System (ADS)

    Burnishev, Yuri; Steinberg, Victor

    2015-08-01

    We report unexpected results of a drastic difference in the transition to fully developed turbulent and turbulent drag reduction (TDR) regimes and in their properties in a von Karman swirling flow with counter-rotating disks of water-based polymer solutions for viscous (by smooth disks) as well as inertial (by bladed disks) forcing and by tracking just torque Γ (t ) and pressure p (t ) . For the viscous forcing, just a single TDR regime is found with the transition values of the Reynolds number (Re) Recturb=RecTDR≃(4.8 ±0.2 ) ×105 independent of ϕ , whereas for the inertial forcing two turbulent regimes are revealed. The first transition is to fully developed turbulence, and the second one is to the TDR regime with both Recturb and RecTDR depending on polymer concentration ϕ . Both regimes differ by the values of Cf and Cp, by the scaling exponents of the fundamental turbulent characteristics, by the nonmonotonic dependencies of skewness and flatness of the pressure PDFs on Re, and by the different frequency power spectra of p with the different dependencies of the main vortex peak frequency in the p power spectra on ϕ and Re. Thus our experimental results show the transition to the TDR regime in a von Karman swirling flow for the viscous and inertial forcings in a sharp contrast to the recent experiments [Phys. Fluids 10, 426 (1998), 10.1063/1.869532; Phys. Rev. E 47, R28(R) (1993), 10.1103/PhysRevE.47.R28; and J. Phys.: Condens. Matter 17, S1195 (2005), 10.1088/0953-8984/17/14/008] where the transition to TDR is observed in the same swirling flow with counter-rotating disks only for the viscous forcing. The latter result has led its authors to the wrong conclusion that TDR is a solely boundary effect contrary to the inertial forcing associated with the bulk effect, and this conception is currently rather widely accepted in literature.

  7. Borehole Time Domain Reflectometry in Layered Sandstone: Impact of Measurement Technique on Vadose Zone Process Identification

    NASA Astrophysics Data System (ADS)

    West, J.; Truss, S. W.

    2004-12-01

    An investigation is reported into the hydraulic behaviour of the vadose zone of a layered sandstone aquifer using borehole-based Time Domain Reflectometry (TDR). TDR has been widely applied to shallow soils but has seen limited application at greater depth and in cemented lithologies due to the difficulty of installing conventional TDR probes in rock and from boreholes. Here, flat TDR probes that are simply in contact with, rather than inserted within the medium under investigation, have been developed and applied in a field study. Both a commercially available portable packer TDR system (TRIME-B3L Borehole Packer Probe) and specially designed TDR probes, permanently installed in boreholes on grouted-in packers were used to monitor seasonal fluctuations in moisture content in the vadose zone of a layered sandstone over one year under natural rainfall loading. The data show that the vadose zone contains seasonal perched water tables that form when downward percolating moisture reaches layers of fine grained sandstone and siltstone and causes local saturation. The formation of perched water tables is likely to lead to lateral flow bypassing the less permeable, finer layers. This contrasts with behaviour inferred from previous studies of the same aquifer that used borehole radar and resistivity, which suggested its vadose zone behaviour was characterized by uniform downwards migration of wetting fronts. To investigate the impact of measurement technique on observed response, the TDR data reported here were used to produce simulated zero offset profile (ZOP) borehole radar responses. This simulation confirmed the limited ability of ZOP borehole radar to detect key vadose zone processes, because the phenomenon of critical refraction minimizes the sensitivity of the results to high moisture content layers. The study illustrates that inappropriate technique selection results in hydrological process mis-identification, with serious consequences for the usefulness of data in hydrological modeling.

  8. Active Time Domain Reflectometry for Tamper Indication in Unattended Safeguards Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheen, David M.; Smith, Leon E.; Tedeschi, Jonathan R.

    2015-07-14

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-cost commerciallymore » available spread-spectrum TDR technology as one option for field implementation. This paper describes the TDR methods under investigation and the associated benchtop test-bed, tampering scenarios of interest,, and viability measurement results to date (e.g., comparison of relative sensitivity to tamper scenarios).« less

  9. A Scientometric Evaluation of the Chagas Disease Implementation Research Programme of the PAHO and TDR

    PubMed Central

    Carbajal-de-la-Fuente, Ana Laura; Yadón, Zaida E.

    2013-01-01

    The Special Programme for Research and Training in Tropical Diseases (TDR) is an independent global programme of scientific collaboration cosponsored by the United Nations Children's Fund, the United Nations Development Program, the World Bank, and the World Health Organization. TDR's strategy is based on stewardship for research on infectious diseases of poverty, empowerment of endemic countries, research on neglected priority needs, and the promotion of scientific collaboration influencing global efforts to combat major tropical diseases. In 2001, in view of the achievements obtained in the reduction of transmission of Chagas disease through the Southern Cone Initiative and the improvement in Chagas disease control activities in some countries of the Andean and the Central American Initiatives, TDR transferred the Chagas Disease Implementation Research Programme (CIRP) to the Communicable Diseases Unit of the Pan American Health Organization (CD/PAHO). This paper presents a scientometric evaluation of the 73 projects from 18 Latin American and European countries that were granted by CIRP/PAHO/TDR between 1997 and 2007. We analyzed all final reports of the funded projects and scientific publications, technical reports, and human resource training activities derived from them. Results about the number of projects funded, countries and institutions involved, gender analysis, number of published papers in indexed scientific journals, main topics funded, patents inscribed, and triatomine species studied are presented and discussed. The results indicate that CIRP/PAHO/TDR initiative has contributed significantly, over the 1997–2007 period, to Chagas disease knowledge as well as to the individual and institutional-building capacity. PMID:24244761

  10. Long term pavement performance computed parameter : moisture content

    DOT National Transportation Integrated Search

    2008-01-01

    A study was conducted to compute in situ soil parameters based on time domain reflectometry (TDR) traces obtained from Long Term Pavement Performance (LTPP) test sections instrumented for the seasonal monitoring program (SMP). Ten TDR sensors were in...

  11. The 5-year cost-effectiveness of two-level anterior cervical discectomy and fusion or cervical disc replacement: a Markov analysis.

    PubMed

    Overley, Samuel C; McAnany, Steven J; Brochin, Robert L; Kim, Jun S; Merrill, Robert K; Qureshi, Sheeraz A

    2018-01-01

    Anterior cervical discectomy and fusion (ACDF) and cervical disc replacement (CDR) are both acceptable surgical options for the treatment of cervical myelopathy and radiculopathy. To date, there are limited economic analyses assessing the relative cost-effectiveness of two-level ACDF versus CDR. The purpose of this study was to determine the 5-year cost-effectiveness of two-level ACDF versus CDR. The study design is a secondary analysis of prospectively collected data. Patients in the Prestige cervical disc investigational device exemption (IDE) study who underwent either a two-level CDR or a two-level ACDF were included in the study. The outcome measures were cost and quality-adjusted life years (QALYs). A Markov state-transition model was used to evaluate data from the two-level Prestige cervical disc IDE study. Data from the 36-item Short Form Health Survey were converted into utilities using the short form (SF)-6D algorithm. Costs were calculated from the payer perspective. QALYs were used to represent effectiveness. A probabilistic sensitivity analysis (PSA) was performed using a Monte Carlo simulation. The base-case analysis, assuming a 40-year-old person who failed appropriate conservative care, generated a 5-year cost of $130,417 for CDR and $116,717 for ACDF. Cervical disc replacement and ACDF generated 3.45 and 3.23 QALYs, respectively. The incremental cost-effectiveness ratio (ICER) was calculated to be $62,337/QALY for CDR. The Monte Carlo simulation validated the base-case scenario. Cervical disc replacement had an average cost of $130,445 (confidence interval [CI]: $108,395-$152,761) with an average effectiveness of 3.46 (CI: 3.05-3.83). Anterior cervical discectomy and fusion had an average cost of $116,595 (CI: $95,439-$137,937) and an average effectiveness of 3.23 (CI: 2.84-3.59). The ICER was calculated at $62,133/QALY with respect to CDR. Using a $100,000/QALY willingness to pay (WTP), CDR is the more cost-effective strategy and would be selected 61.5% of the time by the simulation. Two-level CDR and ACDF are both cost-effective strategies at 5 years. Neither strategy was found to be more cost-effective with an ICER greater than the $50,000/QALY WTP threshold. The assumptions used in the analysis were strongly validated with the results of the PSA. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The TDR: A Repository for Long Term Storage of Geophysical Data and Metadata

    NASA Astrophysics Data System (ADS)

    Wilson, A.; Baltzer, T.; Caron, J.

    2006-12-01

    For many years Unidata has provided easy, low cost data access to universities and research labs. Historically Unidata technology provided access to data in near real time. In recent years Unidata has additionally turned to providing middleware to serve longer term data and associated metadata via its THREDDS technology, the most recent offering being the THREDDS Data Server (TDS). The TDS provides middleware for metadata access and management, OPeNDAP data access, and integration with the Unidata Integrated Data Viewer (IDV), among other benefits. The TDS was designed to support rolling archives of data, that is, data that exist only for a relatively short, predefined time window. Now we are creating an addition to the TDS, called the THREDDS Data Repository (TDR), which allows users to store and retrieve data and other objects for an arbitrarily long time period. Data in the TDR can also be served by the TDS. The TDR performs important functions of locating storage for the data, moving the data to and from the repository, assigning unique identifiers, and generating metadata. The TDR framework supports pluggable components that allow tailoring an implementation for a particular application. The Linked Environments for Atmospheric Discovery (LEAD) project provides an excellent use case for the TDR. LEAD is a multi-institutional Large Information Technology Research project funded by the National Science Foundation (NSF). The goal of LEAD is to create a framework based on Grid and Web Services to support mesoscale meteorology research and education. This includes capabilities such as launching forecast models, mining data for meteorological phenomena, and dynamic workflows that are automatically reconfigurable in response to changing weather. LEAD presents unique challenges in managing and storing large data volumes from real-time observational systems as well as data that are dynamically created during the execution of adaptive workflows. For example, in order to support storage of many large data products, the LEAD implementation of the TDR will provide a variety of data movement options, including gridftp. It will have a web service interface and will be callable programmatically as well as via interactive user requests. Future plans include the use of a mass storage device to provide robust long term storage. This talk will present the current state of the TDR effort.

  13. ReWritable Data Storage on DVD by Using Phase Change Technology

    NASA Astrophysics Data System (ADS)

    Kleine, H.; Martin, F.; Kapeller, M.; Cord, B.; Ebinger, H.

    It is expected that the next few years the VHS casette will be replaced by rewritable Digital Versatile Discs (DVD) for home video recording. At this moment three different standards DVD+RW, DVD-RW and DVD-RAM exist, out of which the DVD+RW is expected to dominate the market in Europe and the United States. The disc holds 4.7 GB of computer data, which is equivalent to several hours of high quality video content. At the heart of the disc is a thin film layer stack with a special phase change recording layer. By proper laser irradiation the disc can be overwritten up to 1000 times without noticeable quality loss. A shelf lifetime of 20-50 years is anticipated. With these characteristics the disc is well suited for consumer applications. The present article illuminates how a process engineer can control the disc recording sensitivity, the recording speed and the number of overwriting cycles by the design of the thin film layer stack.

  14. High-resolution moisture profiles from full-waveform probabilistic inversion of TDR signals

    NASA Astrophysics Data System (ADS)

    Laloy, Eric; Huisman, Johan Alexander; Jacques, Diederik

    2014-11-01

    This study presents an novel Bayesian inversion scheme for high-dimensional undetermined TDR waveform inversion. The methodology quantifies uncertainty in the moisture content distribution, using a Gaussian Markov random field (GMRF) prior as regularization operator. A spatial resolution of 1 cm along a 70-cm long TDR probe is considered for the inferred moisture content. Numerical testing shows that the proposed inversion approach works very well in case of a perfect model and Gaussian measurement errors. Real-world application results are generally satisfying. For a series of TDR measurements made during imbibition and evaporation from a laboratory soil column, the average root-mean-square error (RMSE) between maximum a posteriori (MAP) moisture distribution and reference TDR measurements is 0.04 cm3 cm-3. This RMSE value reduces to less than 0.02 cm3 cm-3 for a field application in a podzol soil. The observed model-data discrepancies are primarily due to model inadequacy, such as our simplified modeling of the bulk soil electrical conductivity profile. Among the important issues that should be addressed in future work are the explicit inference of the soil electrical conductivity profile along with the other sampled variables, the modeling of the temperature-dependence of the coaxial cable properties and the definition of an appropriate statistical model of the residual errors.

  15. Measurement of water pressure and deformation with time domain reflectometry cables

    NASA Astrophysics Data System (ADS)

    Dowding, Charles H.; Pierce, Charles E.

    1995-05-01

    Time domain reflectometry (TDR) techniques can be deployed to measure water pressures and relative dam abutment displacement with an array of coaxial cables either drilled and grouted or retrofitted through existing passages. Application of TDR to dam monitoring requires determination of appropriate cable types and methods to install these cables in existing dams or during new construction. This paper briefly discusses currently applied and developing TDR techniques and describes initial design considerations for TDR-based dam instrumentation. Water pressure at the base of or within the dam can be determined by measuring the water level within a hollow or air-filled coaxial cable. The ability to retrofit existing porous stone-tipped piezometers is an attractive attribute of the TDR system. Measurement of relative lateral movement can be accomplished by monitoring local shearing of a solid polyethylene-filled coaxial cable at the interface of the dam base and foundation materials or along adversely oriented joints. Uplift can be recorded by measuring cable extension as the dam displaces upward off its foundation. Since each monitoring technique requires measurements with different types of coaxial cables, a variety may be installed within the array. Multiplexing of these cables will allow monitoring from a single pulser, and measurements can be recorded on site or remotely via a modem at any time.

  16. The Role of Spatial Dispersion of Repolarization in Inherited and Acquired Sudden Cardiac Death Syndromes

    PubMed Central

    Antzelevitch, Charles

    2007-01-01

    This review examines the role of spatial electrical heterogeneity within ventricular myocardium on the function of the heart in health and disease. The cellular basis for transmural dispersion of repolarization (TDR) is reviewed and the hypothesis that amplification of spatial dispersion of repolarization underlies the development of life-threatening ventricular arrhythmias associated with inherited ion channelopathies is evaluated. The role of TDR in the long QT, short QT and Brugada syndromes as well as catecholaminergic polymorphic ventricular tachycardia (CPVT) are critically examined. In the long QT Syndrome, amplification of TDR is often secondary to preferential prolongation of the action potential duration (APD) of M cells, whereas in the Brugada Syndrome, it is thought to be due to selective abbreviation of the APD of right ventricular (RV) epicardium. Preferential abbreviation of APD of either endocardium or epicardium appears to be responsible for amplification of TDR in the short QT syndrome. In catecholaminergic polymorphic VT, reversal of the direction of activation of the ventricular wall is responsible for the increase in TDR. In conclusion, the long QT, short QT, Brugada and catecholaminergic polymorphic VT syndromes are pathologies with very different phenotypes and etiologies, but which share a common final pathway in causing sudden cardiac death. PMID:17586620

  17. Active methamphetamine use is associated with transmitted drug resistance to non-nucleoside reverse transcriptase inhibitors in individuals with HIV infection of unknown duration.

    PubMed

    Cachay, Edward R; Moini, Niousha; Kosakovsky Pond, Sergei L; Pesano, Rick; Lie, Yolanda S; Aiem, Heidi; Butler, David M; Letendre, Scott; Mathews, Wm Christopher; Smith, Davey M

    2007-01-01

    Frequent methamphetamine use among recently HIV infected individuals is associated with transmitted drug resistance (TDR) to non-nucleoside reverse transcriptase inhibitors (NNRTI); however, the reversion time of TDR to drug susceptible HIV may exceed 3 years. We assessed whether recreational substance use is associated with detectable TDR among individuals newly diagnosed with HIV infection of unknown duration. Cross-sectional analysis. Subjects were enrolled at the University California, San Diego Early Intervention Program. Demographic, clinical and substance use data were collected using structured interviews. Genotypic resistance testing was performed using GeneSeq, Monogram Biosciences. We analyzed the association between substance use and TDR using bivariate analyses and the corresponding transmission networks using phylogenetic models. Between April 2004 and July 2006, 115 individuals with genotype data were enrolled. The prevalence of alcohol, marijuana and methamphetamine use were 98%, 71% and 64% respectively. Only active methamphetamine use in the 30 days prior to HIV diagnosis was independently associated with TDR to NNRTI (OR: 6.6; p=0.002). Despite not knowing the duration of their HIV infection, individuals reporting active methamphetamine use in the 30 days prior to HIV diagnosis are at an increased risk of having HIV strains that are resistant to NNRTI.

  18. Comparing bulk electrical conductivities spatial series obtained by Time Domain Reflectometry and Electromagnetic Induction sensors

    NASA Astrophysics Data System (ADS)

    Saeed, Ali; Ajeel, Ali; dragonetti, giovanna; Comegna, Alessandro; Lamaddalena, Nicola; Coppola, Antonio

    2016-04-01

    The ability to determine and monitor the effects of salts on soils and plants, are of great importance to agriculture. To control its harmful effects, soil salinity needs to be monitored in space and time. This requires knowledge of its magnitude, temporal dynamics, and spatial variability. Conventional ground survey procedures by direct soil sampling are time consuming, costly and destructive. Alternatively, soil salinity can be evaluated by measuring the bulk electrical conductivity (σb) directly in the field. Time domain reflectometry (TDR) sensors allow simultaneous measurements of water content, θ, and σb. They may be calibrated for estimating the electrical conductivity of the soil solution (σw). However, they have a relatively small observation window and thus they are thought to only provide local-scale measurements. The spatial range of the sensors is limited to tens of centimeters and extension of the information to a large area can be problematic. Also, information on the vertical distribution of the σb soil profile may only be obtained by installing sensors at different depths. In this sense, the TDR may be considered as an invasive technique. Compared to the TDR, other geophysical methods based for example on Electromagnetic Induction (EMI) techniques are non-invasive methods and represent a viable alternative to traditional techniques for soil characterization. The problem is that all these techniques give depth-weighted apparent electrical conductivity (σa) measurements, depending on the specific depth distribution of the σb, as well as on the depth response function of the sensor used. In order to deduce the actual distribution of the bulk electrical conductivity, σb, in the soil profile, one needs to invert the signal coming from EMI. Because of their relatively lower observation window, TDR sensors provide quasi-point values and do not adequately integrate the spatial variability of the chemical concentration distribution in the soil solution (and of the water content) induced by natural soil heterogeneity. Thus, the variability of TDR readings is expected to come from a combination of smaller and larger-scale variations. By contrast, an EMI sensor reading partly smoothes the small-scale variability seen by a TDR probe. As a consequence, the variability revealed by profile-integrated EMI and local (within a given depth interval) TDR readings may have completely different characteristics. In this study, a comparison between the variability patterns of σb revealed by TDR and EMI sensors was carried out. The database came from a field experiment conducted in the Mediterranean Agronomic Institute (MAI) of Valenzano (Bari). The soil was pedologically classified as Colluvic Regosol, consisting of a silty loam with an average depth of 60 cm on a shallow fractured calcareous rock. The experimental field (30m x 15.6 m; for a total area of 468 m2) consisted of three transects of 30 m length and 4.2 width, cultivated with green bean and irrigated with three different salinity levels (1 dS/m, 3dS/m, 6dS/m). Each transect consisted of seven crop rows irrigated by a drip irrigation system (dripper discharge q=2 l/h.). Water salinity was induced by adding CaCl2 to the tap water. All crop-soil measurements were conducted along the middle row at 24 monitoring sites, 1m apart. The spatial and temporal evolution of bulk electrical conductivity (σb) of soil was monitored by i) an Electromagnetic Induction method (EM38-DD) and ii) Time Domain Reflectometry (TDR). Herein we will focus on the methodology we used to elaborate the database of this experiment. Mostly, the data elaboration was devoted to make TDR and EMI data actually comparable. Specifically, we analysed the effect of the different observation windows of TDR and EMI sensors on the different spatial and temporal variability observed in the data series coming from the two sensors. After exploring the different patterns and structures of variability of the original EMI and TDR data series the study assessed the potential of applying a Fourier's analysis to filter the original data series to extract the predominant, high-variance signal after removing the small- scale (high frequency) variance observed in the TDR data series.

  19. Surgical Treatment for Discogenic Low-Back Pain: Lumbar Arthroplasty Results in Superior Pain Reduction and Disability Level Improvement Compared With Lumbar Fusion

    PubMed Central

    2007-01-01

    Background The US Food and Drug Administration approved the Charité artificial disc on October 26, 2004. This approval was based on an extensive analysis and review process; 20 years of disc usage worldwide; and the results of a prospective, randomized, controlled clinical trial that compared lumbar artificial disc replacement to fusion. The results of the investigational device exemption (IDE) study led to a conclusion that clinical outcomes following lumbar arthroplasty were at least as good as outcomes from fusion. Methods The author performed a new analysis of the Visual Analog Scale pain scores and the Oswestry Disability Index scores from the Charité artificial disc IDE study and used a nonparametric statistical test, because observed data distributions were not normal. The analysis included all of the enrolled subjects in both the nonrandomized and randomized phases of the study. Results Subjects from both the treatment and control groups improved from the baseline situation (P < .001) at all follow-up times (6 weeks to 24 months). Additionally, these pain and disability levels with artificial disc replacement were superior (P < .05) to the fusion treatment at all follow-up times including 2 years. Conclusions The a priori statistical plan for an IDE study may not adequately address the final distribution of the data. Therefore, statistical analyses more appropriate to the distribution may be necessary to develop meaningful statistical conclusions from the study. A nonparametric statistical analysis of the Charité artificial disc IDE outcomes scores demonstrates superiority for lumbar arthroplasty versus fusion at all follow-up time points to 24 months. PMID:25802574

  20. [Self-assembly tissue engineering fibrocartilage model of goat temporomandibular joint disc].

    PubMed

    Kang, Hong; Li, Zhen-Qiang; Bi, Yan-Da

    2011-06-01

    To construct self-assembly fibrocartilage model of goat temporomandibular joint disc and observe the biological characteristics of the self-assembled fibrocartilage constructs, further to provide a basis for tissue engineering of the temporomandibular joint disc and other fibrocartilage. Cells from temporomandibular joint discs of goats were harvested and cultured. 5.5 x 10(6) cells were seeded in each agarose well with diameter 5 mm x depth 10 mm, daily replace of medium, cultured for 2 weeks. One day after seeding, goat temporomandibular joint disc cells in agarose wells were gathered and began to self-assemble into a disc-shaped base, then gradually turned into a round shape. When cultured for 2 weeks, hematoxylin-eosin staining was conducted and observed that cells were round and wrapped around by the matrix. Positive Safranin-O/fast green staining for glycosaminoglycans was observed throughout the entire constructs, and picro-sirius red staining was examined and distribution of numerous type I collagen was found. Immunohistochemistry staining demonstrated brown yellow particles in cytoplasm and around extracellular matrix, which showed self-assembly construct can produce type I collagen as native temporomandibular joint disc tissue. Production of extracellular matrix in self-assembly construct as native temporomandibular joint disc tissue indicates that the use of agarose wells to construct engineered temporomandibular joint disc will be possible and practicable.

  1. Analysis of the Function of Apoptosis during Imaginal Wing Disc Regeneration in Drosophila melanogaster.

    PubMed

    Diaz-Garcia, Sandra; Ahmed, Sara; Baonza, Antonio

    2016-01-01

    Regeneration is the ability that allows organisms to replace missing organs or lost tissue after injuries. This ability requires the coordinated activity of different cellular processes, including programmed cell death. Apoptosis plays a key role as a source of signals necessary for regeneration in different organisms. The imaginal discs of Drosophila melanogaster provide a particularly well-characterised model system for studying the cellular and molecular mechanisms underlying regeneration. Although it has been shown that signals produced by apoptotic cells are needed for homeostasis and regeneration of some tissues of this organism, such as the adult midgut, the contribution of apoptosis to disc regeneration remains unclear. Using a new method for studying disc regeneration in physiological conditions, we have defined the pattern of cell death in regenerating discs. Our data indicate that during disc regeneration, cell death increases first at the wound edge, but as regeneration progresses dead cells can be observed in regions far away from the site of damage. This result indicates that apoptotic signals initiated in the wound spread throughout the disc. We also present results which suggest that the partial inhibition of apoptosis does not have a major effect on disc regeneration. Finally, our results suggest that during disc regeneration distinct apoptotic signals might be acting simultaneously.

  2. Parallelism between gradient temperature raman spectroscopy and differential scanning calorimetry results

    USDA-ARS?s Scientific Manuscript database

    Temperature dependent Raman spectroscopy (TDR) applies the temperature gradients utilized in differential scanning calorimetry (DSC) to Raman spectroscopy, providing a straightforward technique to identify molecular rearrangements that occur just prior to phase transitions. Herein we apply TDR and D...

  3. A reevaluation of TDR propagation time determination in soils and geological media

    USDA-ARS?s Scientific Manuscript database

    Time domain reflectometry (TDR) is an established method for the determination of apparent dielectric permittivity and water content in soils. Using current waveform interpretation procedures, signal attenuation and variation in dielectric media properties along the transmission line can significant...

  4. Building professional capacity in ITS : guidelines on developing the future professional

    DOT National Transportation Integrated Search

    1999-07-01

    Time domain reflectometry (TDR) has become one of the most reliable methods for measuring in-situ soil moisture content. TDR sensors developed by the Federal Highway Administration (FHWA) are being used in the Long-Term Pavement Performance (LTPP) Se...

  5. TDR water content inverse profiling in layered soils during infiltration and evaporation

    NASA Astrophysics Data System (ADS)

    Greco, R.; Guida, A.

    2009-04-01

    During the last three decades, time domain reflectometry (TDR) has become one of the most commonly used tools for soil water content measurements either in laboratory or in the field. Indeed, TDR provides easy and cheap water content estimations with relatively small disturbance to the investigated soil. TDR measurements of soil water content are based on the strong correlation between relative dielectric permittivity of wet soil and its volumetric water content. Several expressions of the relationship between relative dielectric permittivity and volumetric water content have been proposed, empirically stated (Topp et al., 1980) as well as based on semi-analytical approach to dielectric mixing models (Roth et al., 1990; Whalley, 1993). So far, TDR field applications suffered the limitation due to the capability of the technique of estimating only the mean water content in the volume investigated by the probe. Whereas the knowledge of non homogeneous vertical water content profiles was needed, it was necessary to install either several vertical probes of different length or several horizontal probes placed in the soil at different depths, in both cases strongly increasing soil disturbance as well as the complexity of the measurements. Several studies have been recently dedicated to the development of inversion methods aimed to extract more information from TDR waveforms, in order to estimate non homogeneous moisture profiles along the axis of the metallic probe used for TDR measurements. A common feature of all these methods is that electromagnetic transient through the wet soil along the probe is mathematically modelled, assuming that the unknown soil water content distribution corresponds to the best agreement between simulated and measured waveforms. In some cases the soil is modelled as a series of small layers with different dielectric properties, and the waveform is obtained as the result of the superposition of multiple reflections arising from impedance discontinuities between the layers (Nguyen et al., 1997; Todoroff et al., 1998; Heimovaara, 2001; Moret et al., 2006). Other methods consider the dielectric properties of the soil as smoothly variable along probe axis (Greco, 1999; Oswald et al., 2003; Greco, 2006). Aim of the study is testing the applicability to layered soils of the inverse method for the estimation of water content profiles along vertical TDR waveguides, originally applied in laboratory to homogeneous soil samples with monotonic moisture distributions (Greco, 2006), and recently extended to field measurements with more general water content profiles (Greco and Guida, 2008). Influence of soil electrical conductivity, uniqueness of solution, choices of parametrization, parameters identifiabilty, sensitivity of the method to chosen parameters variations are discussed. Finally, the results of the application of the inverse method to a series of infiltration and evaporation experiments carried out in a flume filled with three soil layers of different physical characteristics are presented. ACKNOWLEDGEMENTS The research was co-financed by the Italian Ministry of University, by means of the PRIN 2006 PRIN program, within the research project entitled ‘Definition of critical rainfall thresholds for destructive landslides for civil protection purposes'. REFERENCES Greco, R., 1999. Measurement of water content profiles by single TDR experiments. In: Feyen, J., Wiyo, K. (Eds.), Modelling of Transport Processes in Soils. Wageningen Pers, Wageningen, the Netherlands, pp. 276-283. Greco, R., 2006. Soil water content inverse profiling from single TDR waveforms. J. Hydrol. 317, 325-339. Greco R., Guida A., 2008. Field measurements of topsoil moisture profiles by vertical TDR probes. J. Hydrol. 348, 442- 451. Heimovaara, T.J., 2001. Frequency domain modelling of TDR waveforms in order to obtain frequency dependent dielectric properties of soil samples: a theoretical approach. In: TDR 2001 - Second International Symposium on Time Domain Reflectometry for Innovative Geotechnical Applications. Northwestern University, Evanston, Illinois, pp. 19-21. Moret, D., Arrue, J.L., Lopez, M.V., Gracia, R., 2006. A new TDR waveform analysis approach for soil moisture profiling using a single probe. J. Hydrol. 321, 163-172. Nguyen, B.L., Bruining, J., Slob, E.C., 1997. Saturation profiles from dielectric (frequency domain reflectometry) measurements in porous media. In: Proceedings of International Workshop on characterization and Measurements of the Hydraulic Properties of Unsaturated Porous Media, Riverside, California, pp. 363-375. Oswald, B., Benedickter, H.R., Ba¨chtold, W., Flu¨hler, H., 2003. Spatially resolved water content profiles from inverted time domain reflectometry signals. Water Resour. Res. 39 (12), 1357. Todoroff, P., Lorion, R., Lan Sun Luk, J.-D., 1998. L'utilisation des génétiques pour l'identification de profils hydriques de sol a` partir de courbes réflectométriques. CR Acad. Sci. Paris, Sciences de la terre et des plane`tes 327, 607-610. Topp, G.C., Davis, J.L., Annan, A.P., 1980. Electromagnetic determination of soil water content: measurement in coaxial transmission lines. Water Resour. Res. 16, 574-582. Roth, K., Schulin, R., Fluhler, H., Attinger, W., 1990. Calibration of time domain reflectometry for water content measurement using a composite dielectric approach. Water Resour. Res. 26, 2267-2273. Whalley, W.R., 1993. Considerations on the use of time domain reflectometry (TDR) for measuring soil water content. J. Soil Sci. 44, 1-9.

  6. Epidemiological Surveillance of HIV-1 Transmitted Drug Resistance in Spain in 2004-2012: Relevance of Transmission Clusters in the Propagation of Resistance Mutations.

    PubMed

    Vega, Yolanda; Delgado, Elena; Fernández-García, Aurora; Cuevas, Maria Teresa; Thomson, Michael M; Montero, Vanessa; Sánchez, Monica; Sánchez, Ana Maria; Pérez-Álvarez, Lucia

    2015-01-01

    Our objectives were to carry out an epidemiological surveillance study on transmitted drug resistance (TDR) among individuals newly diagnosed of HIV-1 infection during a nine year period in Spain and to assess the role of transmission clusters (TC) in the propagation of resistant strains. An overall of 1614 newly diagnosed individuals were included in the study from January 2004 through December 2012. Individuals come from two different Spanish regions: Galicia and the Basque Country. Resistance mutations to reverse transcriptase inhibitors (RTI) and protease inhibitors (PI) were analyzed according to mutations included in the surveillance drug-resistance mutations list updated in 2009. TC were defined as those comprising viruses from five or more individuals whose sequences clustered in maximum likelihood phylogenetic trees with a bootstrap value ≥90%. The overall prevalence of TDR to any drug was 9.9%: 4.9% to nucleoside RTIs (NRTIs), 3.6% to non-nucleoside RTIs (NNRTIs), and 2.7% to PIs. A significant decrease of TDR to NRTIs over time was observed [from 10% in 2004 to 2% in 2012 (p=0.01)]. Sixty eight (42.2%) of 161 sequences with TDR were included in 25 TC composed of 5 or more individuals. Of them, 9 clusters harbored TDR associated with high level resistance to antiretroviral drugs. T215D revertant mutation was transmitted in a large cluster comprising 25 individuals. The impact of epidemiological networks on TDR frequency may explain its persistence in newly diagnosed individuals. The knowledge of the populations involved in TC would facilitate the design of prevention programs and public health interventions.

  7. [Rivastigmine as treatment for patients with mild to moderately severe Alzheimer disease under normal clinical practice conditions. The ENTERPRISE study].

    PubMed

    Cruz Jentoft, A J; Hernández, B

    2014-01-01

    Alzheimer disease (AD) causes progressive cognitive decline leading to loss of independence for activities of daily living; rivastigmine is one of the drugs used for symptomatic management. To assess the therapeutic use of different pharmaceutical forms of rivastigmine in patients with AD in normal clinical practice. Cross-sectional, observational, multi-centre study conducted on patients with mild to moderate AD treated with rivastigmine in Spanish outpatient clinics specialising in Geriatrics, Psychiatry, and Neurology. Data regarding use of oral (OR) and transdermal (TDR) rivastigmine, compliance (degree of adherence), and caregiver satisfaction with treatment were evaluated. In total, 2252 patients with a mean age of 77.2 years were included; 60.2% were women. AD was moderate to moderately severe in 58.4%. Rivastigmine treatment was started orally in 54.4% of the patients and transdermally in 45.6%; 35.6% of those who started treatment by the OR route switched to TDR. A single dose adjustment was sufficient for 77.5% of patients on TDR treatment vs 11.8% of patients receiving OR treatment. More patients on TDR treatment (80.8% vs. 57.1% on OR treatment) reached the maximum therapeutic dose of rivastigmine and did so in a shorter period of time (51.6 vs 205.8 days). Compliance rates (60.5% vs 47.2%) and caregivers' satisfaction with treatment (89.4% vs 81.9%) were also higher for TDR. In normal clinical practice, using the TDR route of administration improves dose titration and drug compliance, allowing more patients to reach the maximum recommended dose of rivastigmine in a shorter time period. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  8. Clinically relevant transmitted drug resistance to first line antiretroviral drugs and implications for recommendations.

    PubMed

    Monge, Susana; Guillot, Vicente; Alvarez, Marta; Chueca, Natalia; Stella, Natalia; Peña, Alejandro; Delgado, Rafael; Córdoba, Juan; Aguilera, Antonio; Vidal, Carmen; García, Federico

    2014-01-01

    The aim was to analyse trends in clinically relevant resistance to first-line antiretroviral drugs in Spain, applying the Stanford algorithm, and to compare these results with reported Transmitted Drug Resistance (TDR) defined by the 2009 update of the WHO SDRM list. We analysed 2781 sequences from ARV naive patients of the CoRIS cohort (Spain) between 2007-2011. Using the Stanford algorithm "Low-level resistance", "Intermediate resistance" and "High-level resistance" categories were considered as "Resistant". 70% of the TDR found using the WHO list were relevant for first-line treatment according to the Stanford algorithm. A total of 188 patients showed clinically relevant resistance to first-line ARVs [6.8% (95%Confidence Interval: 5.8-7.7)], and 221 harbored TDR using the WHO list [7.9% (6.9-9.0)]. Differences were due to a lower prevalence in clinically relevant resistance for NRTIs [2.3% (1.8-2.9) vs. 3.6% (2.9-4.3) by the WHO list] and PIs [0.8% (0.4-1.1) vs. 1.7% (1.2-2.2)], while it was higher for NNRTIs [4.6% (3.8-5.3) vs. 3.7% (3.0-4.7)]. While TDR remained stable throughout the study period, clinically relevant resistance to first line drugs showed a significant trend to a decline (p = 0.02). Prevalence of clinically relevant resistance to first line ARVs in Spain is decreasing, and lower than the one expected looking at TDR using the WHO list. Resistance to first-line PIs falls below 1%, so the recommendation of screening for TDR in the protease gene should be questioned in our setting. Cost-effectiveness studies need to be carried out to inform evidence-based recommendations.

  9. Approximation of Gas Volume in a Seafloor Sediment using Time Domain Reflectometry in the Okhotsk Sea

    NASA Astrophysics Data System (ADS)

    Aoki, S.; Noborio, K.; Matsumoto, R.

    2013-12-01

    Global warming has accelerated in recent decades as the concentration of carbon dioxide has increased in the atmosphere due to fossil fuel burning. In addition, increases in consuming fossil fuels have led to their depletion in recent years. One practical measure to meet these two challenges is the conversion of energy resources to natural gas that has less environmental impact. Gas hydrates that contain natural gas have been discovered in the sea around Japan. They are expected to serve as a new non-conventional natural gas resource. To understand the mechanism of gas hydrate accumulation, the amount of free gas in sediments should be known. However, it is difficult to measure this non-destructively without affecting other properties. In this study we examined a technique for measuring the amount of free gas using Time Domain Reflectometry (TDR). TDR was a method of measuring the dielectric constant of the soil. This method is based on the relationship between the volumetric water content and dielectric constant, to estimate the volumetric water content indirectly. TDR has commonly been used to measure the moisture content of soil such as cultivation and paddy. In our study, we used TDR to estimate the gas ratio in the sea-bottom sediment obtained from the Sea of Okhotsk. Measurement by the TDR method was difficult in a high electrical conductivity solution such as seawater. Therefore, we blunted the measurement sensitivity by coating TDR probe with plastic, which makes it possible to measure. We found that the gas phase rates differed depending on the depth and location, so gas phase existed up to about 10%.

  10. Time domain reflectometry measurements of solute transport across a soil layer boundary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nissen, H.H.; Moldrup, P.; Kachanoski, R.G.

    2000-02-01

    The mechanisms governing solute transport through layered soil are not fully understood. Solute transport at, above, and beyond the interface between two soil layers during quasi-steady-state soil water movement was investigated using time domain reflectometry (TDR). A 0.26-m sandy loam layer was packed on top of a 1.35-m fine sand layer in a soil column. Soil water content ({theta}) and bulk soil electrical conductivity (EC{sub b}) were measured by 50 horizontal and 2 vertical TDR probes. A new TDR calibration method that gives a detailed relationship between apparent relative dielectric permittivity (K{sub s}) and {theta} was applied. Two replicate solutemore » transport experiments were conducted adding a conservative tracer (CCl) to the surface as a short pulse. The convective lognormal transfer function model (CLT) was fitted to the TDR-measured time integral-normalized resident concentration breakthrough curves (BTCs). The BTCs and the average solute-transport velocities showed preferential flow occurred across the layer boundary. A nonlinear decrease in TDR-measured {theta} in the upper soil toward the soil layer boundary suggests the existence of a 0.10-m zone where water is confined towards fingered flow, creating lateral variations in the area-averaged water flux above the layer boundary. A comparison of the time integral-normalized flux concentration measured by vertical and horizontal TDR probes at the layer boundary also indicates a nonuniform solute transport. The solute dispersivity remained constant in the upper soil layer, but increased nonlinearly (and further down, linearly) with depth in the lower layer, implying convective-dispersive solute transport in the upper soil, a transition zone just below the boundary, and stochastic-convective solute transport in the remaining part of the lower soil.« less

  11. Complete Transversal Disc Fracture in a Björk-Shiley Delrin Mitral Valve Prosthesis 43 Years After Implantation.

    PubMed

    González-Santos, Jose María; Arnáiz-García, María Elena; Dalmau-Sorlí, María José; Sastre-Rincón, Jose Alfonso; Hernández-Hernández, Jesús; Pérez-Losada, María Elena; Sagredo-Meneses, Víctor; López-Rodríguez, Javier

    2016-10-01

    A patient who underwent previous implantation of a mitral valve replacement with a Björk-Shiley Delrin (BSD) mitral valve prosthesis during infancy was admitted to our institution 43 years later after an episode of syncope and cardiac arrest. Under extreme hemodynamic instability, a mitral valve prosthetic dysfunction causing massive mitral regurgitation was identified. The patient underwent an emergent cardiac operation, and a complete disc fracture with partial disc migration was found. Exceptional cases of mechanical prosthetic heart valve fracture exist. We report the first case of complete transversal disc rupture of a BSD mitral valve prosthesis after the longest period of implantation ever reported in that position. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Time domain reflectometry waveform analysis with second order bounded mean oscillation

    USDA-ARS?s Scientific Manuscript database

    Tangent-line methods and adaptive waveform interpretation with Gaussian filtering (AWIGF) have been proposed for determining reflection positions of time domain reflectometry (TDR) waveforms. However, the accuracy of those methods is limited for short probe TDR sensors. Second order bounded mean osc...

  13. Study on Elastic Helical TDR Sensing Cable for Distributed Deformation Detection

    PubMed Central

    Tong, Renyuan; Li, Ming; Li, Qing

    2012-01-01

    In order to detect distributed ground surface deformation, an elastic helical structure Time Domain Reflectometry (TDR) sensing cable is shown in this paper. This special sensing cable consists of three parts: a silicone rubber rope in the center; a couple of parallel wires coiling around the rope; a silicone rubber pipe covering the sensing cable. By analyzing the relationship between the impedance and the structure of the sensing cable, the impedance model shows that the sensing cable impedance will increase when the cable is stretched. This specific characteristic is verified in the cable stretching experiment which is the base of TDR sensing technology. The TDR experiment shows that a positive reflected signal is created at the stretching deformation point on the sensing cable. The results show that the deformation section length and the stretching elongation will both affect the amplitude of the reflected signal. Finally, the deformation locating experiments show that the sensing cable can accurately detect the deformation point position on the sensing cable. PMID:23012560

  14. Estimation of water absorption coefficient using the TDR method

    NASA Astrophysics Data System (ADS)

    Suchorab, Zbigniew; Majerek, Dariusz; Brzyski, Przemysław; Sobczuk, Henryk; Raczkowski, Andrzej

    2017-07-01

    Moisture accumulation and transport in the building barriers is an important feature that influences building performance, causing serious exploitation problems as increased energy use, mold and bacteria growth, decrease of indoor air parameters that may lead to sick building syndrome (SBS). One of the parameters that is used to describe moisture characteristic of the material is water absorption coefficient being the measure of capillary behavior of the material as a function of time and the surface area of the specimen. As usual it is determined using gravimetric methods according to EN 1925:1999 standard. In this article we demonstrate the possibility of determination of water absorption coefficient of autoclaved aerated concrete (AAC) using the Time Domain Reflectometry (TDR) method. TDR is an electric technique that had been adopted from soil science and can be successfully used for real-time monitoring of moisture transport in building materials and envelopes. Data achieved using TDR readouts show high correlation with standard method of moisture absorptivity coefficient determination.

  15. Left ventricular epicardial activation increases transmural dispersion of repolarization in healthy, long QT, and dilated cardiomyopathy dogs.

    PubMed

    Bai, Rong; Lü, Jiagao; Pu, Jun; Liu, Nian; Zhou, Qiang; Ruan, Yanfei; Niu, Huiyan; Zhang, Cuntai; Wang, Lin; Kam, Ruth

    2005-10-01

    Benefits of cardiac resynchronization therapy (CRT) are well established. However, less is understood concerning its effects on myocardial repolarization and the potential proarrhythmic risk. Healthy dogs (n = 8) were compared to a long QT interval (LQT) model (n = 8, induced by cesium chloride, CsCl) and a dilated cardiomyopathy with congestive heart failure (DCM-CHF, induced by rapid ventricular pacing, n = 5). Monophasic action potential (MAP) recordings were obtained from the subendocardium, midmyocardium, subepicardium, and the transmural dispersion of repolarization (TDR) was calculated. The QT interval and the interval from the peak to the end of the T wave (T(p-e)) were measured. All these characteristics were compared during left ventricular epicardial (LV-Epi), right ventricular endocardial (RV-Endo), and biventricular (Bi-V) pacing. In healthy dogs, TDR prolonged to 37.54 ms for Bi-V pacing and to 47.16 ms for LV-Epi pacing as compared to 26.75 ms for RV-Endo pacing (P < 0.001), which was parallel to an augmentation in T(p-e) interval (Bi-V pacing, 64.29 ms; LV-Epi pacing, 57.89 ms; RV-Endo pacing, 50.29 ms; P < 0.01). During CsCl exposure, Bi-V and LV-Epi pacing prolonged MAPD, TDR, and T(p-e) interval as compared to RV-Endo pacing. The midmyocardial MAPD (276.30 ms vs 257.35 ms, P < 0.0001) and TDR (33.80 ms vs 27.58 ms, P=0.002) were significantly longer in DCM-CHF dogs than those in healthy dogs. LV-Epi and Bi-V pacing further prolonged the MAPD and TDR in this model. LV-Epi and Bi-V pacing result in prolongation of ventricular repolarization time, and increase of TDR accounted for a parallel augmentation of the T(p-e) interval, which provides evidence that T(p-e) interval accurately represents TDR. These effects are magnified in the LQT and DCM-CHF canine models in addition to their intrinsic transmural heterogeneity in the intact heart. This mechanism may contribute to the development of malignant ventricular arrhythmias, such as torsades de pointes (TdP) in congestive heart failure (CHF) patients treated with CRT.

  16. An improved thermo-time domain reflectometry method for determination of ice contents in partially frozen soils

    NASA Astrophysics Data System (ADS)

    Tian, Zhengchao; Ren, Tusheng; Kojima, Yuki; Lu, Yili; Horton, Robert; Heitman, Joshua L.

    2017-12-01

    Measuring ice contents (θi) in partially frozen soils is important for both engineering and environmental applications. Thermo-time domain reflectometry (thermo-TDR) probes can be used to determine θi based on the relationship between θi and soil heat capacity (C). This approach, however, is accurate in partially frozen soils only at temperatures below -5 °C, and it performs poorly on clayey soils. In this study, we present and evaluate a soil thermal conductivity (λ)-based approach to determine θi with thermo-TDR probes. Bulk soil λ is described with a simplified de Vries model that relates λ to θi. From this model, θi is estimated using inverse modeling of thermo-TDR measured λ. Soil bulk density (ρb) and thermo-TDR measured liquid water content (θl) are also needed for both C-based and λ-based approaches. A theoretical analysis is performed to quantify the sensitivity of C-based and λ-based θi estimates to errors in these input parameters. The analysis indicates that the λ-based approach is less sensitive to errors in the inputs (C, λ, θl, and ρb) than is the C-based approach when the same or the same percentage errors occur. Further evaluations of the C-based and λ-based approaches are made using experimentally determined θi at different temperatures on eight soils with various textures, total water contents, and ρb. The results show that the λ-based thermo-TDR approach significantly improves the accuracy of θi measurements at temperatures ≤-5 °C. The root mean square errors of λ-based θi estimates are only half those of C-based θi. At temperatures of -1 and -2 °C, the λ-based thermo-TDR approach also provides reasonable θi, while the C-based approach fails. We conclude that the λ-based thermo-TDR method can reliably determine θi even at temperatures near the freezing point of water (0 °C).

  17. Directly coupled vs conventional time domain reflectometry in soils

    USDA-ARS?s Scientific Manuscript database

    Time domain reflectometry (TDR), a technique for estimation of soil water, measures the travel time of an electromagnetic pulse on electrodes embedded in the soil, but has limited application in commercial agriculture due to costs, labor, and sensing depth. Conventional TDR systems have employed ana...

  18. Wear characteristics of an unconstrained lumbar total disc replacement under a range of in vitro test conditions

    PubMed Central

    Fisher, John; Hall, Richard M.

    2015-01-01

    Abstract The effect of kinematics, loading and centre of rotation on the wear of an unconstrained total disc replacement have been investigated using the ISO 18192‐1 standard test as a baseline. Mean volumetric wear rate and surface morphological effects were reported. Changing the phasing of the flexions to create a low (but finite) amount of crossing path motion at the bearing surfaces resulted in a significant fall in wear volume. However, the rate of wear was still much larger than previously reported values under zero cross shear conditions. Reducing the load did not result in a significant change in wear rate. Moving the centre of rotation of the disc inferiorly did significantly increase wear rate. A phenomenon of debris re‐attachment on the UHMWPE surface was observed and hypothesised to be due to a relatively harsh tribological operating regime in which lubricant replenishment and particle migration out of the bearing contact zone were limited. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 46–52, 2017. PMID:26411540

  19. Active Methamphetamine Use is Associated with Transmitted Drug Resis-tance to Non-Nucleoside Reverse Transcriptase Inhibitors in Individuals with HIV Infection of Unknown Duration

    PubMed Central

    Cachay, Edward R; Moini, Niousha; Kosakovsky Pond, Sergei L; Pesano, Rick; Lie, Yolanda S; Aiem, Heidi; Butler, David M; Letendre, Scott; Mathews, Wm. Christopher; Smith, Davey M

    2007-01-01

    Background: Frequent methamphetamine use among recently HIV infected individuals is associated with transmitted drug resistance (TDR) to non-nucleoside reverse transcriptase inhibitors (NNRTI); however, the reversion time of TDR to drug susceptible HIV may exceed 3 years. We assessed whether recreational substance use is associated with detectable TDR among individuals newly diagnosed with HIV infection of unknown duration. Design: Cross-sectional analysis. Methods: Subjects were enrolled at the University California, San Diego Early Intervention Program. Demographic, clinical and substance use data were collected using structured interviews. Genotypic resistance testing was performed using GeneSeq™, Monogram Biosciences. We analyzed the association between substance use and TDR using bivariate analyses and the corresponding transmission networks using phylogenetic models. Results: Between April 2004 and July 2006, 115 individuals with genotype data were enrolled. The prevalence of alcohol, marijuana and methamphetamine use were 98%, 71% and 64% respectively. Only active methamphetamine use in the 30 days prior to HIV diagnosis was independently associated with TDR to NNRTI (OR: 6.6; p=0.002). Conclusion: Despite not knowing the duration of their HIV infection, individuals reporting active methamphetamine use in the 30 days prior to HIV diagnosis are at an increased risk of having HIV strains that are resistant to NNRTI. PMID:18923691

  20. Factors affecting the process of CO2 replacement of CH4 from methane hydrate in sediments - Constrained from experimental results

    NASA Astrophysics Data System (ADS)

    Lu, H.; Hu, G.; Vanderveen, J.; Liu, C.; Ratcliffe, C.; Ripmeester, J.

    2011-12-01

    CO2 replacement of CH4 from methane hydrate has been proposed as a method to produce gas from natural gas hydrate by taking advantage of both the production of natural gas and the sequestration of CO2. To examine the validity of this method DOE/Conoco-Philips is considering having a field test in Alaska. The reaction of CO2 replacing CH4 from methane hydrate has been confirmed to be thermodynamically feasible, but concern is always raised about the reaction kinetics. Some kinetic studies in the system of methane hydrate and liquid or gaseous CO2 have found that the reaction proceeds at a very low rate. Natural gas hydrate occurs in sediments with multi-components and complex structure, so matters will be even more complicated. Up to now, few investigations have been carried out concerning the factors affecting the reaction process of CO2 replacing CH4 from methane hydrate. Experiments were implemented with sands, which were recovered from Mallik 5L-38 well, Mackenzie Delta, Northwest Territory, Canada, sediment that previously contained hydrate although it had been dried completely before our experiments. The water-saturated sands were tightly charged into a plastic bottle (90 mm deep and 60 mm wide), and then this test specimen was sealed in a pressure cell. After methane hydrate was synthesized in the test specimen for 108 days under a pressure of 11 to 8 MPa and a temperature of 3 degrees Celsius, liquid CO2 was introduced into the pressure cell. The conditions under which CO2 was reacted with methane hydrate were ~5.3 MPa and 5 degrees Celsius. After reacting for 15 days, the test specimen was recovered. The test specimen was cut into ~10 mm thick discs, and sub-samples were further taken from each of the discs. In addition to the determination of hydrate saturation and the gas composition, Raman spectroscopic studies were carried out for the sub-samples obtained. The results revealed: 1) less CO2 replacement in the bottom disc of the test specimen as compared with that in the top disc, implying that diffusion was a factor that controlled the movement of CO2 in the sediments, 2) an inhomogeneous replacement reaction even within the same disc, indicating that the contact area between methane hydrate and CO2 was a factor that determined the degree of replacement of CH4 from methane hydrate 3) the separate appearance of CO2 Raman intensities and CH4 Raman intensities in some portions of the test specimen, suggesting that CO2 was present in the form of CO2 hydrate in addition to being together with CH4 in other parts of the hydrate. Further analysis found that both CO2 diffusion and the contact area for reaction were associated with the pore structure of the sediments, which were heterogeneous both in pore size and in pore shape as observed with high resolution X-ray CT.

  1. Disc-halo interactions in ΛCDM

    NASA Astrophysics Data System (ADS)

    Bauer, Jacob S.; Widrow, Lawrence M.; Erkal, Denis

    2018-05-01

    We present a new method for embedding a stellar disc in a cosmological dark matter halo and provide a worked example from a Λ cold dark matter zoom-in simulation. The disc is inserted into the halo at a redshift z = 3 as a zero-mass rigid body. Its mass and size are then increased adiabatically while its position, velocity, and orientation are determined from rigid-body dynamics. At z = 1, the rigid disc (RD) is replaced by an N-body disc whose particles sample a three-integral distribution function (DF). The simulation then proceeds to z = 0 with live disc (LD) and halo particles. By comparison, other methods assume one or more of the following: the centre of the RD during the growth phase is pinned to the minimum of the halo potential, the orientation of the RD is fixed, or the live N-body disc is constructed from a two rather than three-integral DF. In general, the presence of a disc makes the halo rounder, more centrally concentrated, and smoother, especially in the innermost regions. We find that methods in which the disc is pinned to the minimum of the halo potential tend to overestimate the amount of adiabatic contraction. Additionally, the effect of the disc on the subhalo distribution appears to be rather insensitive to the disc insertion method. The LD in our simulation develops a bar that is consistent with the bars seen in late-type spiral galaxies. In addition, particles from the disc are launched or `kicked up' to high galactic latitudes.

  2. Water and Salt Stresses, Kinetin and Protein Synthesis in Tobacco Leaves 1

    PubMed Central

    Ben-Zioni, Aliza; Itai, C.; Vaadia, Y.

    1967-01-01

    The capacity of tobacco (Nicotiana rustica) leaf discs to incorporate l-leucine 14C into proteins was measured. Leaf discs were obtained from plants which experienced soil water depletion, or which were exposed to a saline or osmotic stress in the root medium. The stresses were brief of relatively short duration and water potential did not decrease below 4 bars in the root media. Leaf discs were sampled 2 hours after stress removal, achieved by reirrigation, or replacement of saline and osmotic solutions with normal nutrient solution. Plants were always turgid when leaves were sampled. All stressed tissues showed reduced capacity to incorporate l-leucine 14C into protein. The reduction was about 50% and could not be attributed either to reduced uptake into the discs, or to possible isotopic dilution. Incorporation decreased progressively with leaf age in control discs as well as in stressed leaf discs. At all ages tested, incorporation in stressed discs was lower than that of the control. Full recovery of incorporation capacity in stressed discs was obtained when discs were sampled 72 hours after stress removal but not earlier. Kinetin pretreatment prior to incubation with labelled leucine partially restored incorporation in stressed discs. The differences in response to kinetin of stressed and control discs suggest a lower endogenous level of cytokinins in the stressed discs. The results were qualitatively similar regardless of the kind of stress given to the plants during pretreatment. This supports the hypothesis that the normal supply of root cytokinins is important in shoot metabolism. PMID:16656515

  3. The Discover artificial disc replacement versus fusion in cervical radiculopathy--a randomized controlled outcome trial with 2-year follow-up.

    PubMed

    Skeppholm, Martin; Lindgren, Lars; Henriques, Thomas; Vavruch, Ludek; Löfgren, Håkan; Olerud, Claes

    2015-06-01

    Several previous studies comparing artificial disc replacement (ADR) and fusion have been conducted with cautiously positive results in favor of ADR. This study is not, in contrast to most previous studies, an investigational device exemption study required by the Food and Drug Administration for approval to market the product in the United States. This study was partially funded with unrestricted institutional research grants by the company marketing the artificial disc used in this study. To compare outcomes between the concepts of an artificial disc to treatment with anterior cervical decompression and fusion (ACDF) and to register complications associated to the two treatments during a follow-up time of 2 years. This is a randomized controlled multicenter trial, including three spine centers in Sweden. The study included patients seeking care for cervical radiculopathy who fulfilled inclusion criteria. In total, 153 patients were included. Self-assessment with Neck Disability Index (NDI) as a primary outcome variable and EQ-5D and visual analog scale as secondary outcome variables. Patients were randomly allocated to either treatment with the Depuy Discover artificial disc or fusion with iliac crest bone graft and plating. Randomization was blinded to both patient and caregivers until time for implantation. Adverse events, complications, and revision surgery were registered as well as loss of follow-up. Data were available in 137 (91%) of the included and initially treated patients. Both groups improved significantly after surgery. NDI changed from 63.1 to 39.8 in an intention-to-treat analysis. No statistically significant difference between the ADR and the ACDF groups could be demonstrated with NDI values of 39.1 and 40.1, respectively. Nor in secondary outcome measures (EQ-5D and visual analog scale) could any statistically significant differences be demonstrated between the groups. Nine patients in the ADR group and three in the fusion group underwent secondary surgery because of various reasons. Two patients in each group underwent secondary surgery because of adjacent segment pathology. Complication rates were not statistically significant between groups. Artificial disc replacement did not result in better outcome compared to fusion measured with NDI 2 years after surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Cervical Laminoplasty

    MedlinePlus

    ... Medicine Acupuncture Herbal Supplements Surgical Options Anterior Cervical Fusion Artifical Disc Replacement (ADR) Bone Graft Alternatives Bone ... Percutaneous Vertebral Augmentation (PVA) Posterior Cervical Foraminotomy Spinal ... Nonsurgical Treatments Activity Modification Chiropractic – A Conversation with ...

  5. Comparing spatial series of soil bulk electrical conductivity as obtained by Time Domain Reflectometry and Electrical Resistivity Tomography

    NASA Astrophysics Data System (ADS)

    Saeed, Ali; Dragonetti, Giovanna; Comegna, Allessandro; Garre, Sarah; Lamaddalena, Nicola; Coppola, Antonio

    2016-04-01

    Conventional ground survey of soil root zone salinity by direct soil sampling are time consuming, costly and destructive. Alternatively, soil salinity can be evaluated by measuring the bulk electrical conductivity, σb, in the field. This approach is faster and cheaper, and allows a more intensive surveying. Measurements of σb can be made either in situ or with remote devices. Time domain reflectometry (TDR) sensors allow simultaneous measurements of water content, θ, and σb. They may be calibrated for estimating the electrical conductivity of the soil solution (σw). However, they have a relatively small observation window and thus they are thought to only provide local-scale measurements. The spatial range of the sensors is limited to tens of centimeters and extension of the information to a large area can be problematic. Also, information on the vertical distribution of the σb soil profile may only be obtained by installing sensors at different depths. In this sense, the TDR may be considered as an invasive technique. Compared to the TDR, other geophysical methods based for example on the Electrical Resistivity Tomography (ERT) techniques represent an alternative in respect to those traditional for soil salinity characterization. In order to deduce the actual distribution of the bulk electrical conductivity, σb, in the soil profile, one needs to invert the signal coming from ERT sensors. The latter, in turn, depends on the specific depth distribution of the σb, as well as on the electrical configuration of the sensor used. With these premises, the main aim of this study is to estimate the vertical σb distribution starting from resistivity data series measured using the ERT method under different salinity conditions and using TDR data as ground-truth data for calibration and validation of the ERT sensor. This way, limited measured TDR data may be used for translating extensive ERT apparent electrical conductivity, σa, measurements to estimate depth-distributions of σb. These, in turn, may be translated to many σw values by applying the σw-σb-θ calibration relationship obtained in the laboratory by using the TDR probes. A field experiment was conducted in the Mediterranean Agronomic Institute (MAI) of Valenzano (Bari - Italy). The experiment consisted of three transects 30 m long and 4.2 width, cultivated with green bean and irrigated with three different salinity levels (1 dS/m, 3 dS/m, and 6 dS/m). Each transect consisted of seven rows equipped by a dripper irrigation system, which supplied a water flux of 2 l/h. As for the salt application, CaCl2 were dissolved in tap water, and subsequently siphoned into the irrigation system. For each transect, 24 regularly spaced monitoring sites (1 m apart) were selected for soil measurements, using different equipments: i) a TDR100, ii) an ERT apparatus in the Wenner configuration array. Overall, 17 measurement campaigns were carried out. Monitoring along transects also allowed to evaluate the role of different smaller and larger scale heterogeneities on the electrical conductivity measured by the two different sensors. Because of the different variability patterns and structure of the ERT and TDR data due to the different observation windows, a site-by-site comparison of the corresponding readings may not reveal the actual correlation between the σb values deduced by ERT measurements on one side and the TDR data on the other. In order to make TDR and ERT data actually comparable, we analyzed the effect of the different observation windows of the two sensors on the different spatial and temporal variability observed in the two data series. Specifically, the study assessed the potential of applying a Fourier's analysis to filter the original data series to extract the predominant, high-variance signal after removing the small- scale (high frequency) variance observed in the TDR data series.

  6. Cost-effectiveness of lumbar artificial intervertebral disc replacement: driven by the choice of comparator.

    PubMed

    Parkinson, Bonny; Goodall, Stephen; Thavaneswaran, Prema

    2013-09-01

    Lower back pain is a common and costly condition in Australia. This paper aims to conduct an economic evaluation of lumbar artificial intervertebral disc replacement (AIDR) compared with lumbar fusion for the treatment of patients suffering from significant axial back pain and/or radicular (nerve root) pain, secondary to disc degeneration or prolapse, who have failed conservative treatment. A cost-effectiveness approach was used to compare costs and benefits of AIDR to five fusion approaches. Resource use was based on Medicare Benefits Schedule claims data and expert opinion. Effectiveness and re-operation rates were based on published randomized controlled trials. The key clinical outcomes considered were narcotic medication discontinuation, achievement of overall clinical success, achievement of Oswestry Disability Index success and quality-adjusted life-years gained. AIDR was estimated to be cost-saving compared with fusion overall ($1600/patient); however, anterior lumbar interbody fusion and posterolateral fusion were less costly by $2155 and $807, respectively. The incremental cost-effectiveness depends on the outcome considered and the comparator. AIDR is potentially a cost-saving treatment for lumbar disc degeneration, although longer-term follow-up data are required to substantiate this claim. The incremental cost-effectiveness depends on the outcome considered and the comparator, and further research is required before any firm conclusions can be drawn. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  7. Influence of polymer additives on turbulence in von Karman swirling flow between two disks. II

    NASA Astrophysics Data System (ADS)

    Burnishev, Yuri; Steinberg, Victor

    2016-03-01

    We present the experimental studies of the influence of polymer additives on the statistical and scaling properties of the fully developed turbulent regime in a von Karman swirling flow driven either by the smooth or bladed disks using only the global measurements of torque Γ and pressure p fluctuations in water- and water-sugar-based solutions of different viscosities, or elasticity El, and different polymer concentrations ϕ as a function of Re in the same apparatus. There are three highlights achieved and reported in the paper: (i) An observation of turbulent drag reduction (TDR) at both the inertial and viscous flow forcing, in a contradiction to a currently accepted opinion that only the viscous forcing leads to TDR, and the unexpected drastic difference in the transition to the fully developed turbulent and TDR regimes in von Karman swirling flow of water-based polymer solutions depending on the way of the forcing; (ii) a continuous transition to TDR in both the normalized torque drop and the rms pressure fluctuations drop and universality in scaling behavior of Cf in an agreement with theoretical predictions; and (iii) the dramatic differences in the appearance of the frequency power spectra of Γ and in particular p due to the different ways of the forcing are also observed. We discuss and summarize further the results in accordance with these three main achievements. The main message of these studies is that both the inertial forcing and viscous forcing of von Karman swirling flow between two counter-rotating disks lead to TDR in the sharp contrast to the currently accepted opinion [O. Cadot et al., "Turbulent drag reduction in a closed flow system: Boundary layer versus bulk effects," Phys. Fluids 10, 426 (1998); D. Bonn et al., "From scale scales to large scales in three-dimensional turbulence: The effect of diluted polymers," Phys. Rev. E 47, R28 (1993); and D. Bonn et al., "Turbulent drag reduction by polymers," J. Phys.: Condens. Matter 17, S1195 (2005)] that TDR can be observed only at the viscous driving. In this observation, Cadot et al. and Bonn et al., relate to exclusively boundary effect, whereas the existence of TDR in both ways of the flow forcing suggests that both boundary and bulk effects are responsible for TDR. The unexpected result of the striking difference in the transition to the fully developed turbulent and TDR regimes and in their properties in von Karman swirling flow of water-based polymer solutions for the viscous and inertial forcing is reported. For the viscous forcing, just the single turbulent regime is found with the transition values R ec turb = R ec T D R ≃ ( 4 . 8 ± 0 . 2 ) × 1 0 5 independent of polymer concentration ϕ, while for the inertial forcing two turbulent regimes are revealed: fully developed turbulence and the TDR regime with the transition values R ec turb < R ec T D R and both depending on ϕ. Thus in the case of the viscous forcing, the onset to turbulence is not altered by the addition of polymers in the contrast to the inertial forcing, where early turbulence is found. Both regimes differ by the scaling exponents of the fundamental turbulent characteristics, by the dependence of skewness and flatness of probability density functions of p on Re, and by the drastically different frequency power spectra of Γ and p with the different dependencies of their frequency peaks on ϕ. It is also demonstrated that the transition to the TDR state is a continuous one for both Γ ¯ and prms in accord with theoretical arguments and simulations presented in the work of Boffetta et al. ["Drag reduction in the turbulent Kolmogorov flow," Phys. Rev. E 71, 036307 (2005)]. Indeed, Cf presented as a function of R e / R ec T D R for different El show impressive collapse of the data and universal behavior above Rc T D R with the functional dependencies in a full agreement with the prediction from the numerical simulations (Boffetta et al.). Moreover, the crucial issue for the existence of TDR followed from the analysis of stresses in the TDR model is also satisfied in the experiment (Boffetta et al.). As pointed out in the work of Boffetta et al., understanding the reasons of this inequality meaning that the larger effectiveness of the momentum transfer to velocity fluctuations than to elastic stress would reveal the TDR physical mechanism. The power spectra of both Γ and p in the case of the inertial forcing are characterized by the emerging pronounced peaks and their higher harmonics in parallel with up to two orders of magnitude reduction of low frequency fluctuation amplitudes in both the water- and water-sugar-based polymer solutions compared with the power spectra for the Newtonian solvents. The peaks appear at R e ≥ R ec T D R and their normalized peak frequency fp/frot = 0.43 ± 0.02 is independent of El, ϕ, and Re. These observations agree with the numerical results, where the enhancement of the main flow compared to the Newtonian case and the strong reduction of turbulent fluctuations were also observed and quantified. On the other hand, in the case of the viscous forcing, polymers do not alter the appearance of the power spectra of p compared with water, though the scaled peak frequencies fp/frot vary with Re for all ϕ from unity at smaller Re to fp/frot = 0.6 ± 0.02 independent of ϕ and Re in the turbulent regime. Thus the inertial forcing turns out to be much more effective in the pumping energy from turbulent fluctuations into the main vortex due to stronger polymer stretching in the TDR regime that also reveals in more pronounced TDR. We suggest an explanation of the observed effects.

  8. A comparison of second order derivative based models for time domain reflectometry wave form analysis

    USDA-ARS?s Scientific Manuscript database

    Adaptive waveform interpretation with Gaussian filtering (AWIGF) and second order bounded mean oscillation operator Z square 2(u,t,r) are TDR analysis methods based on second order differentiation. AWIGF was originally designed for relatively long probe (greater than 150 mm) TDR waveforms, while Z s...

  9. Accuracy improvement in the TDR-based localization of water leaks

    NASA Astrophysics Data System (ADS)

    Cataldo, Andrea; De Benedetto, Egidio; Cannazza, Giuseppe; Monti, Giuseppina; Demitri, Christian

    A time domain reflectometry (TDR)-based system for the localization of water leaks has been recently developed by the authors. This system, which employs wire-like sensing elements to be installed along the underground pipes, has proven immune to the limitations that affect the traditional, acoustic leak-detection systems. Starting from the positive results obtained thus far, in this work, an improvement of this TDR-based system is proposed. More specifically, the possibility of employing a low-cost, water-absorbing sponge to be placed around the sensing element for enhancing the accuracy in the localization of the leak is addressed. To this purpose, laboratory experiments were carried out mimicking a water leakage condition, and two sensing elements (one embedded in a sponge and one without sponge) were comparatively used to identify the position of the leak through TDR measurements. Results showed that, thanks to the water retention capability of the sponge (which maintains the leaked water more localized), the sensing element embedded in the sponge leads to a higher accuracy in the evaluation of the position of the leak.

  10. Artificial Disc Replacement

    MedlinePlus

    ... Cervical Foraminotomy Spinal Fusion Nonsurgical Treatments Activity Modification Chiropractic – A Conversation with Dr. Jordan Gliedt, DC Directional ... with non-operative care such as medication, injections, chiropractic care and/or physical therapy. Typically, you will ...

  11. The use of polyurethane materials in the surgery of the spine: a review.

    PubMed

    St John, Kenneth R

    2014-12-01

    The spine contains intervertebral discs and the interspinous and longitudinal ligaments. These structures are elastomeric or viscoelastic in their mechanical properties and serve to allow and control the movement of the bony elements of the spine. The use of metallic or hard polymeric devices to replace the intervertebral discs and the creation of fusion masses to replace discs and/or vertebral bodies changes the load transfer characteristics of the spine and the range of motion of segments of the spine. The purpose of the study was to survey the literature, regulatory information available on the Web, and industry-reported device development found on the Web to ascertain the usage and outcomes of the use of polyurethane polymers in the design and clinical use of devices for spine surgery. A systematic review of the available information from all sources concerning the subject materials' usage in spinal devices was conducted. A search of the peer-reviewed literature combining spinal surgery with polyurethane or specific types and trade names of medical polyurethanes was performed. Additionally, information available on the Food and Drug Administration Web site and for corporate Web sites was reviewed in an attempt to identify pertinent information. The review captured devices that are in testing or have entered clinical practice that use elastomeric polyurethane polymers as disc replacements, dynamic stabilization of spinal movement, or motion limitation to relieve nerve root compression and pain and as complete a listing as possible of such devices that have been designed or tested but appear to no longer be pursued. This review summarizes the available information about the uses to which polyurethanes have been tested or are being used in spinal surgery. The use of polyurethanes in medicine has expanded as modifications to the stability of the polymers in the physiological environment have been improved. The potential for the use of elastomeric materials to more closely match the mechanical properties of the structures being replaced and to maintain motion between spinal segments appears to hold promise. The published results from the use of the devices that are discussed show early success with these applications of elastomeric materials. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Full-wave modeling of the time domain reflectometry signal in wetted sandy soils using a random microstructure discretization: Comparison with experiments

    NASA Astrophysics Data System (ADS)

    Rejiba, F.; Sagnard, F.; Schamper, C.

    2011-07-01

    Time domain reflectometry (TDR) is a proven, nondestructive method for the measurement of the permittivity and electrical conductivity of soils, using electromagnetic (EM) waves. Standard interpretation of TDR data leads to the estimation of the soil's equivalent electromagnetic properties since the wavelengths associated with the source signal are considerably greater than the microstructure of the soil. The aforementioned approximation tends to hide an important issue: the influence of the microstructure and phase configuration in the generation of a polarized electric field, which is complicated because of the presence of numerous length scales. In this paper, the influence of the microstructural distribution of each phase on the TDR signal has been studied. We propose a two-step EM modeling technique at a microscale range (?): first, we define an equivalent grain including a thin shell of free water, and second, we solve Maxwell's equations over the discretized, statistically distributed triphasic porous medium. Modeling of the TDR probe with the soil sample was performed using a three-dimensional finite difference time domain scheme. The effectiveness of this hybrid homogenization approach is tested on unsaturated Nemours sand with narrow granulometric fractions. The comparisons made between numerical and experimental results are promising, despite significant assumptions concerning (1) the TDR probe head and the coaxial cable and (2) the assumed effective medium theory homogenization associated with the electromagnetic processes arising locally between the liquid and solid phases at the grain scale.

  13. Quantification of soil water retention parameters using multi-section TDR-waveform analysis

    NASA Astrophysics Data System (ADS)

    Baviskar, S. M.; Heimovaara, T. J.

    2017-06-01

    Soil water retention parameters are important for describing flow in variably saturated soils. TDR is one of the standard methods used for determining water content in soil samples. In this study, we present an approach to estimate water retention parameters of a sample which is initially saturated and subjected to an incremental decrease in boundary head causing it to drain in a multi-step fashion. TDR waveforms are measured along the height of the sample at assumed different hydrostatic conditions at daily interval. The cumulative discharge outflow drained from the sample is also recorded. The saturated water content is obtained using volumetric analysis after the final step involved in multi-step drainage. The equation obtained by coupling the unsaturated parametric function and the apparent dielectric permittivity is fitted to a TDR wave propagation forward model. The unsaturated parametric function is used to spatially interpolate the water contents along TDR probe. The cumulative discharge outflow data is fitted with cumulative discharge estimated using the unsaturated parametric function. The weight of water inside the sample estimated at the first and final boundary head in multi-step drainage is fitted with the corresponding weights calculated using unsaturated parametric function. A Bayesian optimization scheme is used to obtain optimized water retention parameters for these different objective functions. This approach can be used for samples with long heights and is especially suitable for characterizing sands with a uniform particle size distribution at low capillary heads.

  14. Utilizing Time Domain Reflectometry on monitoring bedload in a mountain stream

    NASA Astrophysics Data System (ADS)

    Miyata, S.; Fujita, M.

    2015-12-01

    Understanding bedload transport processes in steep mountain streams is essential for disaster mitigation as well as predicting reservoir capacity and restoration of river ecosystem. Despite various monitoring methods proposed previously, precise bedload monitoring in steep streams still remains difficulty. This study aimed to develop a bedload monitoring system by continuous measurement of thickness and porosity of sediment under water that can be applicable to retention basins and pools in steep streams. When a probe of TDR (Time Domain Reflectometry) measurement system is inserted as to penetrate two adjacent layers with different dielectric constants, analysis of TDR waveform enables us to determine position of the layer boundary and ratio of materials in the layer. Methodology of analyzing observed TDR waveforms were established based on results of a series of column experiment, in which a single TDR probe with length of 40 cm was installed in a column filled with water and, then, sand was supplied gradually. Flume experiment was performed to apply the TDR system on monitoring sediment volume under flowing water conditions. Eight probes with lengths of 27 cm were distributed equally in a model retention basin (i.e., container), into which water and bedload were flowed from a connected flume. The model retention basin was weighed by a load cell and the sediment volume was calculated. A semi-automatic waveform analysis was developed to calculate continuously thicknesses and porosities of the sediment at the eight probes. Relative errors of sediment volume and bedload (=time differential of the volume) were 13 % at maximum, suggesting that the TDR system proposed in this study with multiple probes is applicable to bedload monitoring in retention basins of steep streams. Combination of this system and other indirect bedload monitoring method (e.g., geophone) potentially make a breakthrough for understanding sediment transport processes in steep mountain streams.

  15. Clinically Relevant Transmitted Drug Resistance to First Line Antiretroviral Drugs and Implications for Recommendations

    PubMed Central

    Monge, Susana; Guillot, Vicente; Alvarez, Marta; Chueca, Natalia; Stella, Natalia; Peña, Alejandro; Delgado, Rafael; Córdoba, Juan; Aguilera, Antonio; Vidal, Carmen; García, Federico; CoRIS

    2014-01-01

    Background The aim was to analyse trends in clinically relevant resistance to first-line antiretroviral drugs in Spain, applying the Stanford algorithm, and to compare these results with reported Transmitted Drug Resistance (TDR) defined by the 2009 update of the WHO SDRM list. Methods We analysed 2781 sequences from ARV naive patients of the CoRIS cohort (Spain) between 2007–2011. Using the Stanford algorithm “Low-level resistance”, “Intermediate resistance” and “High-level resistance” categories were considered as “Resistant”. Results 70% of the TDR found using the WHO list were relevant for first-line treatment according to the Stanford algorithm. A total of 188 patients showed clinically relevant resistance to first-line ARVs [6.8% (95%Confidence Interval: 5.8–7.7)], and 221 harbored TDR using the WHO list [7.9% (6.9–9.0)]. Differences were due to a lower prevalence in clinically relevant resistance for NRTIs [2.3% (1.8–2.9) vs. 3.6% (2.9–4.3) by the WHO list] and PIs [0.8% (0.4–1.1) vs. 1.7% (1.2–2.2)], while it was higher for NNRTIs [4.6% (3.8–5.3) vs. 3.7% (3.0–4.7)]. While TDR remained stable throughout the study period, clinically relevant resistance to first line drugs showed a significant trend to a decline (p = 0.02). Conclusions Prevalence of clinically relevant resistance to first line ARVs in Spain is decreasing, and lower than the one expected looking at TDR using the WHO list. Resistance to first-line PIs falls below 1%, so the recommendation of screening for TDR in the protease gene should be questioned in our setting. Cost-effectiveness studies need to be carried out to inform evidence-based recommendations. PMID:24637804

  16. Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.

    PubMed

    Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V

    1992-02-01

    From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.

  17. Tracking the career development of scientists in low- and middle-income countries trained through TDR's research capacity strengthening programmes: Learning from monitoring and impact evaluation.

    PubMed

    Halpaap, Béatrice; Vahedi, Mahnaz; Certain, Edith; Alvarado, Tini; Saint Martin, Caroline; Merle, Corinne; Mihut, Michael; Launois, Pascal

    2017-12-01

    The Special Programme for Research and Training in Tropical Diseases (TDR) co-sponsored by UNICEF, UNDP, World Bank and WHO has been supporting research capacity strengthening in low- and middle-income countries for over 40 years. In order to assess and continuously optimize its capacity strengthening approaches, an evaluation of the influence of TDR training grants on research career development was undertaken. The assessment was part of a larger evaluation conducted by the European Science Foundation. A comprehensive survey questionnaire was developed and sent to a group of 117 trainees supported by TDR who had completed their degree (masters or PhD) between 2000 and 2012; of these, seventy seven (77) responded. Most of the respondents (80%) rated TDR support as a very important factor that influenced their professional career achievements. The "brain drain" phenomenon towards high-income countries was particularly low amongst TDR grantees: the rate of return to their region of origin upon completion of their degree was 96%. A vast majority of respondents are still working in research (89%), with 81% of respondents having participated in multidisciplinary research activities; women engaged in multidisciplinary collaboration to a higher extent than men. However, only a minority of all have engaged in intersectoral collaboration, an aspect that would require further study. The post-degree career choices made by the respondents were strongly influenced by academic considerations. At the time of the survey, 92% of all respondents hold full-time positions, mainly in the public sector. Almost 25% of the respondents reported that they had influenced policy and practice changes. Some of the challenges and opportunities faced by trainees at various stages of their research career have been identified. Modalities to overcome these will require further investigation. The survey evidenced how TDR's research capacity grant programmes made a difference on researchers' career development and on south-south collaborations, by strengthening and localizing research capacity in lower income regions, and also showed there is more that needs to be done. The factors involved, challenges and lessons learnt may help donors and policy makers improve their future interventions with regard to designing capacity strengthening programmes and setting funding priorities.

  18. Cost-effectiveness of cervical total disc replacement vs fusion for the treatment of 2-level symptomatic degenerative disc disease.

    PubMed

    Ament, Jared D; Yang, Zhuo; Nunley, Pierce; Stone, Marcus B; Kim, Kee D

    2014-12-01

    Cervical total disc replacement (CTDR) was developed to treat cervical spondylosis, while preserving motion. While anterior cervical discectomy and fusion (ACDF) has been the standard of care for 2-level disease, a randomized clinical trial (RCT) suggested similar outcomes. Cost-effectiveness of this intervention has never been elucidated. To determine the cost-effectiveness of CTDR compared with ACDF. Data were derived from an RCT that followed up 330 patients over 24 months. The original RCT consisted of multi-institutional data including private and academic institutions. Using linear regression for the current study, health states were constructed based on the stratification of the Neck Disability Index and a visual analog scale. Data from the 12-item Short-Form Health Survey questionnaires were transformed into utilities values using the SF-6D mapping algorithm. Costs were calculated by extracting Diagnosis-Related Group codes from institutional billing data and then applying 2012 Medicare reimbursement rates. The costs of complications and return-to-work data were also calculated. A Markov model was built to evaluate quality-adjusted life-years (QALYs) for both treatment groups. The model adopted a third-party payer perspective and applied a 3% annual discount rate. Patients included in the original RCT had to be diagnosed as having radiculopathy or myeloradiculopathy at 2 contiguous levels from C3-C7 that was unresponsive to conservative treatment for at least 6 weeks or demonstrated progressive symptoms. Incremental cost-effectiveness ratio of CTDR compared with ACDF. A strong correlation (R2 = 0.6864; P < .001) was found by projecting a visual analog scale onto the Neck Disability Index. Cervical total disc replacement had an average of 1.58 QALYs after 24 months compared with 1.50 QALYs for ACDF recipients. Cervical total disc replacement was associated with $2139 greater average cost. The incremental cost-effectiveness ratio of CTDR compared with ACDF was $24,594 per QALY at 2 years. Despite varying input parameters in the sensitivity analysis, the incremental cost-effectiveness ratio value stays below the threshold of $50,000 per QALY in most scenarios (range, -$58,194 to $147,862 per QALY). The incremental cost-effectiveness ratio of CTDR compared with traditional ACDF is lower than the commonly accepted threshold of $50,000 per QALY. This remains true with varying input parameters in a robust sensitivity analysis, reaffirming the stability of the model and the sustainability of this intervention.

  19. Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation

    PubMed Central

    Liao, Zhenhua; Fogel, Guy R.; Pu, Ting; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF). Material/Methods Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P). Results Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p<0.05). 3DPD construct resulted in slight increase at the 3 instrumented levels (p>0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (p<0.05). Both 3DPD and 3PDP caused significant reduction of ROM at the arthrodesis level and produced motion increase at the arthroplasty level. For adjacent levels, 3P resulted in markedly increased contribution of both upper and lower adjacent levels (p<0.05). Significant motion increases lower than 3P were only noted at partly adjacent levels in some conditions for 3DPD and 3PDP (p<0.05). Conclusions ACDF eliminated motion within the construct and greatly increased adjacent motion. Artificial cervical disc replacement normalized motion of its segment and adjacent segments. While hybrid conditions failed to restore normal motion within the construct, they significantly normalized motion in adjacent segments compared with the 3-level ACDF condition. The artificial disc in 3-level constructs has biomechanical advantages compared to fusion in normalizing motion. PMID:26529430

  20. Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation.

    PubMed

    Liao, Zhenhua; Fogel, Guy R; Pu, Ting; Gu, Hongsheng; Liu, Weiqiang

    2015-11-03

    The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF). Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P). Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p<0.05). 3DPD construct resulted in slight increase at the 3 instrumented levels (p>0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (p<0.05). Both 3DPD and 3PDP caused significant reduction of ROM at the arthrodesis level and produced motion increase at the arthroplasty level. For adjacent levels, 3P resulted in markedly increased contribution of both upper and lower adjacent levels (p<0.05). Significant motion increases lower than 3P were only noted at partly adjacent levels in some conditions for 3DPD and 3PDP (p<0.05). ACDF eliminated motion within the construct and greatly increased adjacent motion. Artificial cervical disc replacement normalized motion of its segment and adjacent segments. While hybrid conditions failed to restore normal motion within the construct, they significantly normalized motion in adjacent segments compared with the 3-level ACDF condition. The artificial disc in 3-level constructs has biomechanical advantages compared to fusion in normalizing motion.

  1. A waveguide-on-access-tube (WOAT) TDR sensor for deep soil water content and bulk EC

    USDA-ARS?s Scientific Manuscript database

    A waveguide-on-access-tube (WOAT) TDR sensor was invented and the design optimized through a combination of electromagnetic modeling and several rounds of prototyping and testing in air, water, mixtures of water and ethylene glycol, sand, and silty clay loam soils over a range of water contents and ...

  2. Surveillance of transmitted HIV drug resistance using matched plasma and dried blood spot specimens from voluntary counseling and testing sites in Ho Chi Minh City, Vietnam, 2007-2008.

    PubMed

    Duc, Nguyen Bui; Hien, Bui Thu; Wagar, Nick; Tram, Tran Hong; Giang, Le Truong; Yang, Chunfu; Wolfe, Mitchell I; Hien, Nguyen Tran; Tuan, Nguyen Anh

    2012-05-01

    During 2007-2008, surveillance of transmitted human immunodeficiency virus (HIV) drug resistance (TDR) was performed following World Health Organization guidance among clients with newly diagnosed HIV infection attending voluntary counseling and testing (VCT) sites in Ho Chi Minh City (HCMC), Vietnam. Moderate (5%-15%) TDR to nonnucleoside reverse-transcriptase inhibitors (NNRTIs) was observed among VCT clients aged 18-21 years. Follow-up surveillance of TDR in HCMC and other geographic regions of Vietnam is warranted. Data generated will guide the national HIV drug resistance surveillance strategy and support selection of current and future first-line antiretroviral therapy and HIV prevention programs.

  3. A Model-Based Probabilistic Inversion Framework for Wire Fault Detection Using TDR

    NASA Technical Reports Server (NTRS)

    Schuet, Stefan R.; Timucin, Dogan A.; Wheeler, Kevin R.

    2010-01-01

    Time-domain reflectometry (TDR) is one of the standard methods for diagnosing faults in electrical wiring and interconnect systems, with a long-standing history focused mainly on hardware development of both high-fidelity systems for laboratory use and portable hand-held devices for field deployment. While these devices can easily assess distance to hard faults such as sustained opens or shorts, their ability to assess subtle but important degradation such as chafing remains an open question. This paper presents a unified framework for TDR-based chafing fault detection in lossy coaxial cables by combining an S-parameter based forward modeling approach with a probabilistic (Bayesian) inference algorithm. Results are presented for the estimation of nominal and faulty cable parameters from laboratory data.

  4. Doughnut strikes sandwich: the geometry of hot medium in accreting black hole X-ray binaries

    NASA Astrophysics Data System (ADS)

    Poutanen, Juri; Veledina, Alexandra; Zdziarski, Andrzej A.

    2018-06-01

    We study the effects of the mutual interaction of hot plasma and cold medium in black hole binaries in their hard spectral state. We consider a number of different geometries. In contrast to previous theoretical studies, we use a modern energy-conserving code for reflection and reprocessing from cold media. We show that a static corona above an accretion disc extending to the innermost stable circular orbit produces spectra not compatible with those observed. They are either too soft or require a much higher disc ionization than that observed. This conclusion confirms a number of previous findings, but disproves a recent study claiming an agreement of that model with observations. We show that the cold disc has to be truncated in order to agree with the observed spectral hardness. However, a cold disc truncated at a large radius and replaced by a hot flow produces spectra which are too hard if the only source of seed photons for Comptonization is the accretion disc. Our favourable geometry is a truncated disc coexisting with a hot plasma either overlapping with the disc or containing some cold matter within it, also including seed photons arising from cyclo-synchrotron emission of hybrid electrons, i.e. containing both thermal and non-thermal parts.

  5. A Structurally and Functionally Biomimetic Biphasic Scaffold for Intervertebral Disc Tissue Engineering

    PubMed Central

    Choy, Andrew Tsz Hang; Chan, Barbara Pui

    2015-01-01

    Tissue engineering offers high hopes for the treatment of intervertebral disc (IVD) degeneration. Whereas scaffolds of the disc nucleus and annulus have been extensively studied, a truly biomimetic and mechanically functional biphasic scaffold using naturally occurring extracellular matrix is yet to be developed. Here, a biphasic scaffold was fabricated with collagen and glycosaminoglycans (GAGs), two of the most abundant extracellular matrix components in the IVD. Following fabrication, the scaffold was characterized and benchmarked against native disc. The biphasic scaffold was composed of a collagen-GAG co-precipitate making up the nucleus pulposus-like core, and this was encapsulated in multiple lamellae of photochemically crosslinked collagen membranes comprising the annulus fibrosus-like lamellae. On mechanical testing, the height of our engineered disc recovered by ~82-89% in an annulus-independent manner, when compared with the 99% recovery exhibited by native disc. The annulus-independent nature of disc height recovery suggests that the fluid replacement function of the engineered nucleus pulposus core might mimic this hitherto unique feature of native disc. Biphasic scaffolds comprised of 10 annulus fibrosus-like lamellae had the best overall mechanical performance among the various designs owing to their similarity to native disc in most aspects, including elastic compliance during creep and recovery, and viscous compliance during recovery. However, the dynamic mechanical performance (including dynamic stiffness and damping factor) of all the biphasic scaffolds was similar to that of the native discs. This study contributes to the rationalized design and development of a biomimetic and mechanically viable biphasic scaffold for IVD tissue engineering. PMID:26115332

  6. The impact of transmission clusters on primary drug resistance in newly diagnosed HIV-1 infection.

    PubMed

    Yerly, Sabine; Junier, Thomas; Gayet-Ageron, Angèle; Amari, Emmanuelle Boffi El; von Wyl, Viktor; Günthard, Huldrych F; Hirschel, Bernard; Zdobnov, Evgeny; Kaiser, Laurent

    2009-07-17

    To monitor HIV-1 transmitted drug resistance (TDR) in a well defined urban area with large access to antiretroviral therapy and to assess the potential source of infection of newly diagnosed HIV individuals. All individuals resident in Geneva, Switzerland, with a newly diagnosed HIV infection between 2000 and 2008 were screened for HIV resistance. An infection was considered as recent when the positive test followed a negative screening test within less than 1 year. Phylogenetic analyses were performed by using the maximum likelihood method on pol sequences including 1058 individuals with chronic infection living in Geneva. Of 637 individuals with newly diagnosed HIV infection, 20% had a recent infection. Mutations associated with resistance to at least one drug class were detected in 8.5% [nucleoside reverse transcriptase inhibitors (NRTIs), 6.3%; non-nucleoside reverse transcriptase inhibitors (NNRTIs), 3.5%; protease inhibitors, 1.9%]. TDR (P-trend = 0.015) and, in particular, NNRTI resistance (P = 0.002) increased from 2000 to 2008. Phylogenetic analyses revealed that 34.9% of newly diagnosed individuals, and 52.7% of those with recent infection were linked to transmission clusters. Clusters were more frequent in individuals with TDR than in those with sensitive strains (59.3 vs. 32.6%, respectively; P < 0.0001). Moreover, 84% of newly diagnosed individuals with TDR were part of clusters composed of only newly diagnosed individuals. Reconstruction of the HIV transmission networks using phylogenetic analysis shows that newly diagnosed HIV infections are a significant source of onward transmission, particularly of resistant strains, thus suggesting an important self-fueling mechanism for TDR.

  7. Facilitating the Funding for the Conservation Through Tradeable Development Rights: AN Approach Through Mapping and Analyzing the Built Heritage at Ahmedabad, India

    NASA Astrophysics Data System (ADS)

    Routh, R.; Shah, P.

    2013-07-01

    In India, most of the built heritage is still retained by private ownership, who usually are un inproficient to provide the monetary support for the upkeep of the building. In such a scenario, the property goes into deterioration and is gradually lost. In response to this, the Ahmedabad Urban Develepment Authority (AUDA) have introduced a policy named Tradable Development Rights (TDR) for listed structures within the historic core of Ahmedabad, which will help in generating revenue for conservation of the built heritage. This paper discusses an apparatus which will assist the process of TDR by forming a common platform between the stakeholders to increase efficiency in the procurement and transaction procedure. The system comprises of a procedure which puts all the listed properties on an interactive map, classified according to the grade assigned to each along with the present physical condition of the building, along with information such as the heritage value, contact details, available FSI through TDR and at what amount. The map has been developed using Open Source GIS, and will act as a model for mapping and managing the inventory generated for Ahmedabad. This will help the builders approach the properties which have been graded in terms of importance and urgency as well as simultaneously providing public awareness by through necessary information which the property owner should know to avail the monetary benefits through TDR. The paper also highlights a comparative analysis and benefits of procuring the FSI available through TDR for the historic core.

  8. New types of time domain reflectometry sensing waveguides for bridge scour monitoring

    NASA Astrophysics Data System (ADS)

    Lin, Chih-Ping; Wang, Kai; Chung, Chih-Chung; Weng, Yu-Wen

    2017-07-01

    Scour is a major threat to bridge safety, especially in harsh fluvial environments. Real-time monitoring of bridge scour is still very limited due to the lack of robust and economic scour monitoring device. Time domain reflectometry (TDR) is an emerging waveguide-based technique holding great promise to develop more durable scour monitoring devices. This study presents new types of TDR sensing waveguides in forms of either sensing rod or sensing wire, taking into account of the measurement range, durability, and ease of field installation. The sensing rod is composed of a hollow grooved steel rod paired up with a metal strip on the insulating groove, while the sensing wire consists of two steel strands with one of them coated with an insulating jacket. The measurement sensitivity is inevitably sacrificed when other properties such as the measurement range, field durability, and installation easiness are enhanced. Factors affecting the measurement sensitivity were identified and experimentally evaluated for better arranging the waveguide conductors. A data reduction method for scour-depth estimation without the need for identifying the sediment/water reflection and a two-step calibration procedure for rating propagation velocities were proposed to work with the new types of TDR sensing waveguides. Both the calibration procedure and the data reduction method were experimentally validated. The test results indicated that the new TDR sensing waveguide provides accurate scour depth measurements regardless of the sacrificed sensitivity. The insulating coating of the new TDR sensing waveguide was also demonstrated to be effective in extending the measurement range up to at least 15 m.

  9. Active Time-Domain Reflectometry for Unattended Safeguards Systems: FY16 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Conrad, Ryan C.

    2016-10-21

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Traditional data security measures, for example tamper-indicating (TI) conduit, are impractical for the long separation distances (often 100 meters or more) between unattended monitoring system (UMS) components. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) for the detection of cable tampering in unattended radiation detection systems. The instrument concept under investigation would allow formore » unmanned cable integrity measurements, remote surveillance reporting and locating of cable faults and/or tampers. This report describes PNNL’s FY16 progress and includes: an overview of the TDR methods under investigation; description of the TDR evaluation testbed developed by PNNL; development and testing of advanced signal processing algorithms to extract weak signals from relatively high noise levels; and initial testing of a laboratory prototype intended for IAEA UMS applications and based on a commercially available TDR module. Preliminary viability findings and recommendations for the next stage of development and testing are provided.« less

  10. Biological treatment strategies for disc degeneration: potentials and shortcomings

    PubMed Central

    Nerlich, Andreas G.; Boos, Norbert

    2006-01-01

    Recent advances in molecular biology, cell biology and material sciences have opened a new emerging field of techniques for the treatment of musculoskeletal disorders. These new treatment modalities aim for biological repair of the affected tissues by introducing cell-based tissue replacements, genetic modifications of resident cells or a combination thereof. So far, these techniques have been successfully applied to various tissues such as bone and cartilage. However, application of these treatment modalities to cure intervertebral disc degeneration is in its very early stages and mostly limited to experimental studies in vitro or in animal studies. We will discuss the potential and possible shortcomings of current approaches to biologically cure disc degeneration by gene therapy or tissue engineering. Despite the increasing number of studies examining the therapeutic potential of biological treatment strategies, a practicable solution to routinely cure disc degeneration might not be available in the near future. However, knowledge gained from these attempts might be applied in a foreseeable future to cure the low back pain that often accompanies disc degeneration and therefore be beneficial for the patient. PMID:16983559

  11. Development of a Tunnel Diode Resonator technique for magnetic measurements in Electrostatic Levitation chamber

    NASA Astrophysics Data System (ADS)

    Spyrison, N. S.; Prommapan, P.; Kim, H.; Maloney, J.; Rustan, G. E.; Kreyssig, A.; Goldman, A. I.; Prozorov, R.

    2011-03-01

    The incorporation of the Tunnel Diode Resonator (TDR) technique into an ElectroStatic Levitation (ESL) apparatus was explored. The TDR technique is known to operate and behave well at low temperatures with careful attention to coil-sample positioning in a dark, shielded environment. With these specifications a frequency resolution of 10-9 in a few seconds counting time can be achieved. Complications arise when this technique is applied in the ESL chamber where a sample of molten metal is levitating less then 10 mm from the coil in a large electrostatic field. We have tested a variety of coils unconventional to TDR; including Helmholtz pairs and Archimedean spiral coils. Work was supported by the Nation Science Foundation under grant DMR-08-17157

  12. Building coherence and synergy among global health initiatives.

    PubMed

    Zicker, Fabio; Faid, Miriam; Reeder, John; Aslanyan, Garry

    2015-12-09

    The fast growth of global health initiatives (GHIs) has raised concerns regarding achievement of coherence and synergy among distinct, complementary and sometimes competing activities. Herein, we propose an approach to compare GHIs with regard to their main purpose and operational aspects, using the Special Programme for Research and Training in Tropical Diseases (TDR/WHO) as a case study. The overall goal is to identify synergies and optimize efforts to provide solutions to reduce the burden of diseases. Twenty-six long-established GHIs were identified from among initiatives previously associated/partnered with TDR/WHO. All GHIs had working streams that would benefit from linking to the capacity building or implementation research focus of TDR. Individual profiles were created using a common template to collect information on relevant parameters. For analytical purposes, GHIs were simultaneously clustered in five and eight groups according to their 'intended outcome' and 'operational framework', respectively. A set of specific questions was defined to assess coherence/alignment against a TDR reference profile by attributing a score, which was subsequently averaged per GHI cluster. GHI alignment scores for intended outcome were plotted against scores for operational framework; based on the analysis of coherence/alignment with TDR functions and operations, a risk level (high, medium or low) of engagement was attributed to each GHI. The process allowed a bi-dimensional ranking of GHIs with regards to how adequately they fit with or match TDR features and perspectives. Overall, more consistence was observed with regard to the GHIs' main goals and expected outcomes than with their operational aspects, reflecting the diversity of GHI business models. Analysis of coherence indicated an increasing common trend for enhancing the engagement of developing country stakeholders, building research capacity and optimization of knowledge management platforms in support of improved access to healthcare. The process used offers a broader approach that could be adapted by other GHIs to build coherence and synergy with peer organizations and helps highlight the potential contribution of each GHI in the new era of sustainable development goals. Emerging opportunities and new trends suggest that engagement between GHIs should be selective and tailored to ensure efficient collaborations.

  13. Trends in Transmission of Drug Resistance and Prevalence of Non-B Subtypes in Patients with Acute or Recent HIV-1 Infection in Barcelona in the Last 16 Years (1997-2012).

    PubMed

    Ambrosioni, Juan; Sued, Omar; Nicolas, David; Parera, Marta; López-Diéguez, María; Romero, Anabel; Agüero, Fernando; Marcos, María Ángeles; Manzardo, Christian; Zamora, Laura; Gómez-Carrillo, Manuel; Gatell, José María; Pumarola, Tomás; Miró, José María

    2015-01-01

    To evaluate the prevalence of transmitted drug resistance (TDR) and non-B subtypes in patients with acute/recent HIV-1 infection in Barcelona during the period 1997-2012. Patients from the "Hospital Clínic Primary HIV-1 Infection Cohort" with a genotyping test performed within 180 days of infection were included. The 2009 WHO List of Mutations for Surveillance of Transmitted HIV-1 Drug Resistance was used for estimating the prevalence of TDR and phylogenetic analysis for subtype determination. 189 patients with acute/recent HIV-1 infection were analyzed in 4 time periods (1997-2000, n=28; 2001-4, n=42; 2005-8, n=55 and 2009-12, n=64). The proportion of patients with acute/recent HIV-1 infection with respect to the total of newly HIV-diagnosed patients in our center increased over the time and was 2.18%, 3.82%, 4.15% and 4.55% for the 4 periods, respectively (p=0.005). The global prevalence of TDR was 9%, or 17.9%, 9.5%, 3.6% and 9.4% by study period (p=0.2). The increase in the last period was driven by protease-inhibitor and nucleoside-reverse-transcriptase-inhibitor resistance mutations while non-nucleoside-reverse-transcriptase inhibitor TDR and TDR of more than one family decreased. The overall prevalence of non-B subtypes was 11.1%, or 0%, 4.8%, 9.1% and 20.3 by study period (p=0.01). B/F recombinants, B/G recombinants and subtype F emerged in the last period. We also noticed an increase in the number of immigrant patients (p=0.052). The proportion of men-who-have-sex-with-men (MSM) among patients with acute/recent HIV-1 infection increased over the time (p=0.04). The overall prevalence of TDR in patients with acute/recent HIV-1 infection in Barcelona was 9%, and it has stayed relatively stable in recent years. Non-B subtypes and immigrants proportions progressively increased.

  14. The Formation and Fragmentation of Primordial Protostellar Discs

    NASA Astrophysics Data System (ADS)

    Clark, Paul C.; Glover, Simon C. O.; Smith, Rowan J.; Greif, Thomas H.; Klessen, Ralf S.; Bromm, Volker

    2010-11-01

    We study the formation and evolution of the protostellar discs that form around the first stars in the Universe. Using sink particles, we replace the gravitationally bound gas at densities higher than 1015 cm-3 and radii greater than 3 AU from the central protostellar core, with an accreting point mass that is able to gravitationally interact with the surrounding gas. We find the disc is gravitationally (or `Toomre') unstable, and is dominated by a strong m = 2 spiral mode. Although the angular momentum transport is dominated by a combination of gravitational torques and Reynolds stresses, which are extremely efficient mechanisms, the disc is unable to process the infalling material and grows increasingly gravitationally unstable. During the build-up of the disc, the temperature in the gas is regulated by a combination of H2 line cooling, collision-induced emission and H2 dissociation, which together help to offset heating from the gravitational collapse and feedback from the protostar. Once the disc starts to fragment, H2 dissociation keeps the gas almost isothermal as the collapse of the fragment progresses. The fragmentation occurs when the protostar/disc system is only 230 yr old and at a distance of ~20 AU from its sibling, by which point the central protostar has a mass of ~1 Msolar. Given the angular momentum of the new protostellar system, it is likely that the protostars will grow to become a massive binary system.

  15. Exploring the binding of 4-thiothymidine with human serum albumin by spectroscopy, atomic force microscopy, and molecular modeling methods.

    PubMed

    Zhang, Juling; Gu, Huaimin; Zhang, Xiaohui

    2014-01-30

    The interaction of 4-thiothymidine (S(4)TdR) with human serum albumin (HSA) was studied by equilibrium dialysis under normal physiological conditions. In this work, the mechanism of the interaction between S(4)TdR and human serum albumin (HSA) was exploited by fluorescence, UV, CD circular, and SERS spectroscopic. Fluorescence and UV spectroscopy suggest that HSA intensities are significantly decreased when adding S(4)TdR to HAS, and the quenching mechanism of the fluorescence is static. Also, the ΔG, ΔH, and ΔS values across temperature indicated that hydrophobic interaction was the predominant binding force. The CD circular results show that there is little change in the secondary structure of HSA except the environment of amino acid changes when adding S(4)TdR to HSA. The surface-enhanced Raman scattering (SERS) shows that the interaction between S(4)TdR and HSA can be achieved through different binding sites which are probably located in the II A and III A hydrophobic pockets of HSA which correspond to Sudlow's I and II binding sites. In addition, the molecular modeling displays that S(4)TdR-HSA complex is stabilized by hydrophobic forces, which result from amino acid residues. The atomic force microscopy results revealed that the single HSA molecular dimensions were larger after interaction of 4-thiothymidine. This work would be useful to understand the state of the transportation, distribution, and metabolism of the anticancer drugs in the human body, and it could provide a useful biochemistry parameter for the development of new anti-cancer drugs and research of pharmacology mechanisms. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Incident and long-term HIV-1 infection among pregnant women in Brazil: Transmitted drug resistance and mother-to-child transmission.

    PubMed

    Lima, Yanna Andressa Ramos; Cardoso, Ludimila Paula Vaz; Reis, Mônica Nogueira da Guarda; Stefani, Mariane Martins Araújo

    2016-11-01

    Primary infection, seroconversion, and transmitted drug resistance (TDR) during pregnancy may influence the risk of mother-to-child-transmission (MTCT) of HIV-1 infection. This study estimated recent seroconversion, TDR rates, HIV-1 subtypes and pregnancy outcomes among 95 recently diagnosed, antiretroviral (ARV)-naïve pregnant women recruited during antenatal care in central western Brazil. Recent seroconversion was defined by BED-capture enzyme immunoassay (<155 days) and ambiguous nucleotides base calls (<1 year) in pol sequences (protease-PR and reverse transcriptase-RT regions). TDR was evaluated by the Calibrated Population Resistance tool. HIV-1 subtypes were defined by REGA and phylogenetic analyses. The median age of participants was 25 years; the median gestational age at diagnosis was 20.5 weeks. Based on serology and sequence polymorphism, recent infection was identified in 11.6% (11/95) and, 9 of them (82%), probably seroconverted during pregnancy; one MTCT case was observed among them. Three cases of stillbirth were observed among chronic infected patients (3.6%; 3/84). Moderate rate of TDR was observed (9/90, 10%, CI95% 4.7-18.1%). Subtype B was 60% (54/90), 13.3% (12/90) was subtype C, 6.7% (6/90) was subtype F1. Recombinant B(PR) /F1(RT) and F1(PR) /B(RT) viruses comprised 15.5% (14/90); B(PR) /C(RT) mosaics represented 4.4% (4/90). Seroconversion during pregnancy, late presentation to antenatal care and moderate TDR identified in this study represent significant challenges for the MTCT elimination. J. Med. Virol. 88:1936-1943, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Towards elimination of visceral leishmaniasis in the Indian subcontinent—Translating research to practice to public health

    PubMed Central

    Kroeger, Axel; Matlashewski, Greg; Mondal, Dinesh; Banjara, Megha Raj; Das, Pradeep; Be-Nazir, Ahmed; Arana, Byron; Olliaro, Piero

    2017-01-01

    Background The decade following the Regional Strategic Framework for Visceral Leishmaniasis (VL) elimination in 2005 has shown compelling progress in the reduction of VL burden in the Indian subcontinent. The Special Programme for Research and Training in Tropical Diseases (TDR), hosted by the World Health Organization (WHO) and other stakeholders, has coordinated and financed research for the development of new innovative tools and strategies to support the regional VL elimination initiative. This paper describes the process of the TDR’s engagement and contribution to this initiative. Methodology/principal findings Multiple databases were searched to identify 152 scientific papers and reports with WHO funding or authorship affiliation around the following 3 framework strategies: detection of new cases, morbidity reduction, and prevention of infection. TDR has played a critical role in the evaluation and subsequent use of the 39-aminoacid–recombinant kinesin antigen (rK39) rapid diagnostic test (RDT) as a confirmatory test for VL in the national program. TDR has supported the clinical research and development of miltefosine and single-dose liposomal amphotericin B as a first-line treatment against VL. TDR has engaged with in-country researchers, national programme managers, and partners to generate evidence-based interventions for early detection and treatment of VL patients. TDR evaluated the quality, community acceptance, and cost effectiveness of indoor residual spraying, insecticide-treated bed nets, insecticide-impregnated durable wall linings, insecticidal paint, and environmental management as tools for integrated vector management in reducing sandfly density. Conclusions/significance TDR’s engagement with country policy makers, scientists, and clinicians in the development of effective diagnosis, treatment, case detection, and vector control represents an important example of TDR’s stewardship toward the elimination of VL in the Indian subcontinent. PMID:29023446

  18. Transmitted Drug Resistance and Phylogenetic Relationships among Acute and Early HIV-1 Infected Individuals in New York City

    PubMed Central

    Castor, Delivette; Low, Andrea; Evering, Teresa; Karmon, Sharon; Davis, Brandi; Figueroa, Amir; LaMar, Melissa; Garmon, Donald; Mehandru, Saurabh; Markowitz, Martin

    2012-01-01

    Background Transmitted drug resistance (TDR) is critical to managing HIV-1 infected individuals as well as being a public health concern. Here we report on TDR prevalence and include analyses of phylogenetic clustering of HIV-1 in a predominantly MSM cohort diagnosed during acute/recent HIV-1 infection (AHI) in New York City. Methods Genotypic resistance testing was conducted on plasma samples of 600 individuals with AHI (1995–2010). Sequences were used for resistance and phylogenetic analyses. Demographic and clinical data were abstracted from medical records. TDR was defined according to IAS USA and Stanford HIV database guidelines. Phylogenetic and other analyses were conducted using PAUP*4.0 and SAS, respectively. Results The mean duration since HIV-1 infection was 66.5 days. TDR prevalence was 14.3%, and stably ranged between 10.8% and 21.6% (Ptrend=0.42). NRTI resistance declined from 15.5% to 2.7% over the study period (Ptrend=0.005). M41L (3.7%), T215Y (4.0%), and K103N/S (4.7%) were the most common mutations. K103N/S prevalence increased from 1.9% to 8.0% between 1995 and 2010 (Ptrend=0.04). Using a rigorous definition of clustering, 19.3% (112/581) of subtype B viral sequences co-segregated into transmission clusters, and clusters increased over time. There were fewer and smaller transmission clusters than had been reported in a similar cohort in Montreal, but similar to reports from elsewhere. Conclusions TDR is stable in this cohort and remains a significant concern to both individual patient management and the public health. PMID:22592583

  19. Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

    PubMed

    Baxter, Ryan M; Macdonald, Daniel W; Kurtz, Steven M; Steinbeck, Marla J

    2013-06-05

    Wear, oxidation, and particularly rim impingement damage of ultra-high molecular weight polyethylene total disc replacement components have been observed following surgical revision. However, neither in vitro testing nor retrieval-based evidence has shown the effect(s) of impingement on the characteristics of polyethylene wear debris. Thus, we sought to determine (1) differences in polyethylene particle size, shape, number, or biological activity that correspond to mild or severe rim impingement and (2) in an analysis of all total disc replacements, regardless of impingement classification, whether there are correlations between the extent of regional damage and the characteristics of polyethylene wear debris. The extent of dome and rim damage was characterized for eleven retrieved polyethylene cores obtained at revision surgery after an average duration of implantation of 9.7 years (range, 4.6 to 16.1 years). Polyethylene wear debris was isolated from periprosthetic tissues with use of nitric acid and was imaged with use of environmental scanning electron microscopy. Subsequently, particle size, shape, number, biological activity, and chronic inflammation scores were determined. Grouping of particles by size ranges that represented high biological relevance (<0.1 to 1-μm particles), intermediate biological relevance (1 to 10-μm particles), and low biological relevance (>10-μm particles) revealed an increased volume fraction of particles in the <0.1 to 1-μm and 1 to 10-μm size ranges in the mild-impingement cohort as compared with the severe-impingement cohort. The increased volume fractions resulted in a higher specific biological activity per unit particle volume in the mild-impingement cohort than in the severe-impingement cohort. However, functional biological activity, which is normalized by particle volume (mm3/g of tissue), was significantly higher in the severe-impingement cohort. This increase was due to a larger volume of particles in all three size ranges. In both cohorts, the functional biological activity correlated with the chronic inflammatory response, and the extent of rim penetration positively correlated with increasing particle size, number, and functional biological activity. The results of this study suggest that severe rim impingement increases the production of biologically relevant particles from motion-preserving lumbar total disc replacement components. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  20. Severe Impingement of Lumbar Disc Replacements Increases the Functional Biological Activity of Polyethylene Wear Debris

    PubMed Central

    Baxter, Ryan M.; MacDonald, Daniel W.; Kurtz, Steven M.; Steinbeck, Marla J.

    2013-01-01

    Background: Wear, oxidation, and particularly rim impingement damage of ultra-high molecular weight polyethylene total disc replacement components have been observed following surgical revision. However, neither in vitro testing nor retrieval-based evidence has shown the effect(s) of impingement on the characteristics of polyethylene wear debris. Thus, we sought to determine (1) differences in polyethylene particle size, shape, number, or biological activity that correspond to mild or severe rim impingement and (2) in an analysis of all total disc replacements, regardless of impingement classification, whether there are correlations between the extent of regional damage and the characteristics of polyethylene wear debris. Methods: The extent of dome and rim damage was characterized for eleven retrieved polyethylene cores obtained at revision surgery after an average duration of implantation of 9.7 years (range, 4.6 to 16.1 years). Polyethylene wear debris was isolated from periprosthetic tissues with use of nitric acid and was imaged with use of environmental scanning electron microscopy. Subsequently, particle size, shape, number, biological activity, and chronic inflammation scores were determined. Results: Grouping of particles by size ranges that represented high biological relevance (<0.1 to 1-μm particles), intermediate biological relevance (1 to 10-μm particles), and low biological relevance (>10-μm particles) revealed an increased volume fraction of particles in the <0.1 to 1-μm and 1 to 10-μm size ranges in the mild-impingement cohort as compared with the severe-impingement cohort. The increased volume fractions resulted in a higher specific biological activity per unit particle volume in the mild-impingement cohort than in the severe-impingement cohort. However, functional biological activity, which is normalized by particle volume (mm3/g of tissue), was significantly higher in the severe-impingement cohort. This increase was due to a larger volume of particles in all three size ranges. In both cohorts, the functional biological activity correlated with the chronic inflammatory response, and the extent of rim penetration positively correlated with increasing particle size, number, and functional biological activity. Conclusions: The results of this study suggest that severe rim impingement increases the production of biologically relevant particles from motion-preserving lumbar total disc replacement components. Level of Evidence: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:23780545

  1. Geometry of the intervertebral volume and vertebral endplates of the human spine.

    PubMed

    van der Houwen, E B; Baron, P; Veldhuizen, A G; Burgerhof, J G M; van Ooijen, P M A; Verkerke, G J

    2010-01-01

    Replacement of a degenerated vertebral disc with an artificial intervertebral disc (AID) is currently possible, but poses problems, mainly in the force distribution through the vertebral column. Data on the intervertebral disc space geometry will provide a better fit of the prosthesis to the vertebrae, but current literature on vertebral disc geometry is very scarce or not suitable. In this study, existing CT-scans of 77 patients were analyzed to measure the intervertebral disc and vertebral endplate geometry of the lumbar spine. Ten adjacent points on both sides of the vertebrae (S1-superior to T12-inferior) and sagittal and transverse diameters were measured to describe the shape of the caudal and cranial vertebral planes of the vertebrae. It was found that the largest endplate depth is located in the middle or posterior regions of the vertebra, that there is a linear relationship between all inferior endplate depths and the endplate location (p < 0.0001) within the spinal column, and that the superior endplate depth increases with age by about 0.01 mm per year (p < 0.02). The wedge angle increases from T12-L1 to L5-S1. The results allow for improvement of the fit of intervertebral disc-prostheses to the vertebrae and optimized force transmission through the vertebral column.

  2. Time domain reshuffling for OFDM based indoor visible light communication systems.

    PubMed

    You, Xiaodi; Chen, Jian; Yu, Changyuan; Zheng, Huanhuan

    2017-05-15

    For orthogonal frequency division multiplexing (OFDM) based indoor visible light communication (VLC) systems, partial non-ideal transmission conditions such as insufficient guard intervals and a dispersive channel can result in severe inter-symbol crosstalk (ISC). By deriving from the inverse Fourier transform, we present a novel time domain reshuffling (TDR) concept for both DC-biased optical (DCO-) and asymmetrically clipped optical (ACO-) OFDM VLC systems. By using only simple operations in the frequency domain, potential high peaks can be relocated within each OFDM symbol to alleviate ISC. To simplify the system, we also propose an effective unified design of the TDR schemes for both DCO- and ACO-OFDM. Based on Monte-Carlo simulations, we demonstrate the statistical distribution of the signal high peak values and the complementary cumulative distribution function of the peak-to-average power ratio under different cases for comparison. Simulation results indicate improved bit error rate (BER) performance by adopting TDR to counteract ISC deterioration. For example, for binary phase shift keying at a BER of 10 -3 , the signal to noise ratio gains are ~1.6 dB and ~6.6 dB for DCO- and ACO-OFDM, respectively, with ISC of 1/64. We also show a reliable transmission by adopting TDR for rectangle 8-quadrature amplitude modulation with ISC of < 1/64.

  3. Postero-Lateral Disc Prosthesis Combined With a Unilateral Facet Replacement Device Maintains Quantity and Quality of Motion at a Single Lumbar Level

    PubMed Central

    Nayak, Aniruddh N.; Doarn, Michael C.; Gaskins, Roger B.; James, Chris R.; Cabezas, Andres F.; Castellvi, Antonio E.

    2014-01-01

    Background Mechanically replacing one or more pain generating articulations in the functional spinal unit (FSU) may be a motion preservation alternative to arthrodesis at the affected level. Baseline biomechanical data elucidating the quantity and quality of motion in such arthroplasty constructs is non-existent. Purpose The purpose of the study was to quantify the motion-preserving effect of a posterior total disc replacement (PDR) combined with a unilateral facet replacement (FR) system at a single lumbar level (L4-L5). We hypothesized that reinforcement of the FSU with unilateral FR to replace the resected, native facet joint following PDR implantation would restore quality and quantity of motion and additionally not change biomechanics at the adjacent levels. Study Design In-vitro study using human cadaveric lumbar spines. Methods Six (n = 6) cadaveric lumbar spines (L1-S1) were evaluated using a pure-moment stability testing protocol (±7.5 Nm) in flexion-extension (F/E), lateral bending (LB) and axial rotation (AR). Each specimen was tested in: (1) intact; (2) unilateral FR; and (3) unilateral FR + PDR conditions. Index and adjacent level ROM (using hybrid protocol) were determined opto-electronically. Interpedicular travel (IPT) and instantaneous center of rotation (ICR) at the index level were radiographically determined for each condition. ROM, ICR, and IPT measurements were compared (repeated measures ANOVA) between the three conditions. Results Compared to the intact spine, no significant changes in F/E, LB or AR ROM were identified as a result of unilateral FR or unilateral FR + PDR. No significant changes in adjacent L3-L4 or L5-S1 ROM were identified in any loading mode. No significant differences in IPT were identified between the three test conditions in F/E, LB or AR at the L4-L5 level. The ICRs qualitatively were similar for the intact and unilateral FR conditions and appeared to follow placement (along the anterior-posterior (AP) direction) of the PDR in the disc space Conclusion Biomechanically, quantity and quality of motion are maintained with combined unilateral FR + PDR at a single lumbar spinal level. PMID:25694929

  4. Fatigue based design and analysis of wheel hub for Student formula car by Simulation Approach

    NASA Astrophysics Data System (ADS)

    Gowtham, V.; Ranganathan, A. S.; Satish, S.; Alexis, S. John; Siva kumar, S.

    2016-09-01

    In the existing design of Wheel hub used for Student formula cars, the brake discs cannot be removed easily since the disc is mounted in between the knuckle and hub. In case of bend or any other damage to the disc, the replacement of the disc becomes difficult. Further using OEM hub and knuckle that are used for commercial vehicles will result in increase of unsprung mass, which should be avoided in Student formula cars for improving the performance. In this design the above mentioned difficulties have been overcome by redesigning the hub in such a way that the brake disc could be removed easily by just removing the wheel and the caliper and also it will have reduced weight when compared to existing OEM hub. A CAD Model was developed based on the required fatigue life cycles. The forces acting on the hub were calculated and linear static structural analysis was performed on the wheel hub for three different materials using ANSYS Finite Element code V 16.2. The theoretical fatigue strength was compared with the stress obtained from the structural analysis for each material.

  5. Plant GSK3 proteins regulate xylem cell differentiation downstream of TDIF-TDR signalling

    NASA Astrophysics Data System (ADS)

    Kondo, Yuki; Ito, Tasuku; Nakagami, Hirofumi; Hirakawa, Yuki; Saito, Masato; Tamaki, Takayuki; Shirasu, Ken; Fukuda, Hiroo

    2014-03-01

    During plant radial growth typically seen in trees, procambial and cambial cells act as meristematic cells in the vascular system to self-proliferate and differentiate into xylem cells. These two processes are regulated by a signalling pathway composed of a peptide ligand and its receptor; tracheary element differentiation inhibitory factor (TDIF) and TDIF RECEPTOR (TDR). Here we show that glycogen synthase kinase 3 proteins (GSK3s) are crucial downstream components of the TDIF signalling pathway suppressing xylem differentiation from procambial cells. TDR interacts with GSK3s at the plasma membrane and activates GSK3s in a TDIF-dependent fashion. Consistently, a specific inhibitor of plant GSK3s strongly induces xylem cell differentiation through BRI1-EMS SUPPRESSOR 1 (BES1), a well-known target transcription factor of GSK3s. Our findings provide insight into the regulation of cell fate determination in meristem maintenance.

  6. The predisposing factors for the heterotopic ossification after cervical artificial disc replacement.

    PubMed

    Yi, Seong; Shin, Dong Ah; Kim, Keung Nyun; Choi, Gwihyun; Shin, Hyun Chul; Kim, Keun Su; Yoon, Do Heum

    2013-09-01

    Heterotopic ossification (HO) is defined as a formation of bone outside the skeletal system. The reported HO occurrence rate in cervical artificial disc replacement (ADR) is unexpectedly high and is known to vary. However, the predisposing factors for HO in cervical ADR have not yet been elucidated. Investigation of the predisposing factors of HO in cervical arthroplasty and the relationship between degeneration of the cervical spine and HO occurrence. Retrospective study to discover predisposing factors of HO in cervical arthroplasty. A total of 170 patients who underwent cervical ADR were enrolled including full follow-up clinical and radiologic data. Radiologic outcomes were assessed by identification of HOs according to McAfee's classifications. This study enrolled a total of 170 patients who underwent cervical ADR. Pre-existing degenerative change included anterior or posterior osteophytes, ossification of the anterior longitudinal ligament, posterior longitudinal ligament, or ligamentum nuchae. The relationships between basic patient data, pre-existing degenerative change, and HO were investigated using linear logistic regression analysis. Among all 170 patients, HO was found in 69 patients (40.6%). Among the postulated predisposing factors, only male gender and artificial disc device type were shown to be statistically significant. Unexpectedly, preoperative degenerative changes in the cervical spine exerted no significant influence on the occurrence of HOs. The odds ratio of male gender compared with female gender was 2.117. With regard to device type, the odds ratios of Mobi-C (LDR medical, Troyes, France) and ProDisc-C (Synthes, Inc., West Chester, PA, USA) were 5.262 and 7.449, respectively, compared with the Bryan disc. Definite differences in occurrence rate according to the gender of patients and the prosthesis type were identified in this study. Moreover, factors indefinably expected to influence HO in the past were not shown to be risk factors thereof, the results of which may be meaningful to future studies. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Cervical disc arthroplasty: Pros and cons.

    PubMed

    Moatz, Bradley; Tortolani, P Justin

    2012-01-01

    Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing.

  8. Spatial distribution of soil moisture obtained from gravimetric and TDR methods for SMOS validation, at the Polesie test site SVRT 3275, in Poland

    NASA Astrophysics Data System (ADS)

    Usowicz, B.; Marczewski, W.; Lipiec, J.; Usowicz, J. B.; Sokolowska, Z.; Dabkowska-Naskret, H.; Hajnos, M.; Lukowski, M. I.

    2009-04-01

    The purpose is obtaining trustful ground based measurement data of SM (Soil Moisture) for validating SMOS, respectively to spatial and temporal distribution and variations. A use of Time Domain Reflectometric (TDR) method is fast, simple and less destructive, to the soil matter, than a usual standard gravimetric method. TDR tools operate efficiently, enable nearly instant measurements, and allow on collecting many measurements from numerous sites, even when operated manually in short time intervals. The method enables also very frequent sampling of SM at few selected fixed sites, when long terms of temporal variations are needed. In effect one obtains reasonably large data base for determining spatial and temporal distributions of SM. The study is devoted to determining a plan on collecting TDR data, in the scales of small and large field areas, and checking their relevance to those available from gravimetric methods. Finally, the ground based SM distributions are needed for validating other SM distributions, available remotely in larger scales, from the satellite data of ENVISAT-ASAR, and from SMOS (Soil Moisture and Ocean Salinity Mission) when it becomes operational. The ground based evaluations are served mainly by geo-statistical analysis. The space borne estimations are retrieved by image processing and physical models, proper to relevant Remote Sensing (RS) instruments on the orbit. Finally, validation must engage again the geo-statistical evaluations, to assess the agreement between direct and remote sensing means, and provide a measure of trust for extending the limited scales of the ground based data, on concluding the agreement in scales proper to the satellite data. The study is focused mainly on trustful evaluating data from the ground, provided independently on satellite data sources. SM ground based data are collected permanently at 2 selected tests sites, and temporary in areas around the tests sites, in one day sessions, repeated several times per vegetation season. Permanent measurements are provided in profiles, down to 50 cm below surface. Temporary SM measurements are collected by hand held TDR (FOM/mts type, Easy Test Ltd., Lublin, Poland) from the top surface layer (1-6 cm), in a grid covering small and large areas, containing few hundred sites. The same places are served by collecting soil samples for the gravimetric analysis of SM, bulk density, other physical and textural characteristics. Sessions on measurement in large areas on the scale of community are repeated for separate days. The two methods used were compared with correlation coefficient, regression equation and differences of values. The spatial variability of soil moisture from gravimetric and TDR measurements were analyzed using geostatistical methods. The semivariogram parameters were determined and mathematical functions were fitted to empirically derived semivariograms. These functions were used for estimation of spatial distribution of soil moisture in cultivated fields by the kriging method. The results showed that spatial distribution patterns of topsoil soil moisture in the investigated areas obtained from TDR and gravimetric methods were in general similar to each other. The TDR soil moisture contents were dependent on bulk density and texture of soil. In areas with fine-textured soils of lower soil bulk densities (approximately below 1.35 Mg m^-3) we observed that TDR soil moisture and spatial differentiation were greater compared to those with gravimetric method. However at higher bulk densities the inverse was true. The spatial patterns were further modified in areas with domination of coarse-textured soils. Decrease of measurement points results in smoothing soil moisture pattern and at the same time in a greater estimation error. The TDR method can be useful tool for ground moisture measurements and validation of satellite data. The use of specific calibration or correction for soil bulk density and texture with respect to the reflectometric method is recommended. The study is a contribution to the project SWEX (AO-3275) and funded by the Polish Ministry of Science and Higher Education (in part by Grant No. N305 046 31/1707 and in part by Grant No. N305 107 32/3865).

  9. Rapid Percolation of Water through Soil Macropores Affects Reading and Calibration of Large Encapsulated TDR Sensors

    NASA Astrophysics Data System (ADS)

    Matula, Svatopluk; Dolezal, Frantisek; Moreira Barradas, Joao Manuel

    2015-04-01

    The electromagnetic soil water content sensors are invaluable tools because of their selective sensitivity to water, versatility, ease of automation and large resolution. A common drawback of most their types is their preferential sensitivity to water near to their surfaces. The ways in which the drawback manifests itself were explored for the case of large Time-Domain Reflectometry (TDR) sensors Aqua-Tel-TDR (Automata, Inc., now McCrometer CONNECT). Their field performance was investigated and compared with the results of field and laboratory calibration. The field soil was loamy Chernozem on a carbonate-rich loess substrate, while the laboratory calibration was done in fine quartz sand. In the field, the sensors were installed horizontally into pre-bored holes after being wrapped in slurry of native soil or fine earth. Large sensor-to-sensor variability of readings was observed. It was partially removed by field calibration. The occurrence of percolation events could be easily recognised, because they made the TDR readings suddenly rising and sometimes considerably exceeding the saturated water content. After the events, the TDR readings fell, usually equally suddenly, remaining afterwards at the levels somewhat higher than those before the event. These phenomena can be explained by the preferential flow of water in natural and artificial soil macropores around the sensors. It is hypothesised that the percolating water which enters the gaps and other voids around the sensors accumulates there for short time, being hindered by the sensors themselves. This water also has a enlarged opportunity to get absorbed by the adjacent soil matrix. The variance of TDR readings obtained during the field calibration does not differ significantly from the variance of the corresponding gravimetric sampling data. This suggests that the slope of the field calibration equation is close to unity, in contrast to the laboratory calibration in quartz sand. This difference in slopes can be explained by the presence or absence, respectively, of gaps around the sensors. A typical percolation event and dry period records are presented and analysed. Sensors of this type can be used for qualitative detection of preferential flow and perhaps also for its quantification. The readings outside the percolation events indicate that the sensor environment imitates the native soil reasonably well and that the field-calibrated sensors can provide us with quantitative information about the actual soil water content.

  10. A TDR-Based Soil Moisture Monitoring System with Simultaneous Measurement of Soil Temperature and Electrical Conductivity

    PubMed Central

    Skierucha, Wojciech; Wilczek, Andrzej; Szypłowska, Agnieszka; Sławiński, Cezary; Lamorski, Krzysztof

    2012-01-01

    Elements of design and a field application of a TDR-based soil moisture and electrical conductivity monitoring system are described with detailed presentation of the time delay units with a resolution of 10 ps. Other issues discussed include the temperature correction of the applied time delay units, battery supply characteristics and the measurement results from one of the installed ground measurement stations in the Polesie National Park in Poland. PMID:23202009

  11. Spatial Fluctuations of the Intergalactic Temperature-Density Relation After Hydrogen Reionization

    NASA Astrophysics Data System (ADS)

    Keating, Laura C.; Puchwein, Ewald; Haehnelt, Martin G.

    2018-04-01

    The thermal state of the post-reionization IGM is sensitive to the timing of reionization and the nature of the ionizing sources. We have modelled here the thermal state of the IGM in cosmological radiative transfer simulations of a realistic, extended, spatially inhomogeneous hydrogen reionization process, carefully calibrated with Lyα forest data. We compare these with cosmological simulations run using a spatially homogeneous ionizing background. The simulations with a realistic growth of ionized regions and a realistic spread in reionization redshifts show, as expected, significant spatial fluctuations in the temperature-density relation (TDR) of the post-reionization IGM. The most recently ionized regions are hottest and exhibit a flatter TDR. In simulations consistent with the average TDR inferred from Lyα forest data, these spatial fluctuations have a moderate but noticeable effect on the statistical properties of the Lyα opacity of the IGM at z ˜ 4 - 6. This should be taken into account in accurate measurements of the thermal properties of the IGM and the free-streaming of dark matter from Lyα forest data in this redshift range. The spatial variations of the TDR predicted by our simulations are, however, smaller by about a factor two than would be necessary to explain the observed large spatial opacity fluctuations on large (≥ 50 h-1 comoving Mpc) scales at z ≳ 5.5.

  12. In sickness or in health: TDR's partners. 6. The French Development Research Institute (ORSTOM).

    PubMed

    1997-10-01

    One of the partner agencies working with the UN Development Program/World Bank/World Health Organization Special Programme for Research and Training in Tropical Diseases (TDR) is the French development research agency, ORSTOM. ORSTOM has been conducting research in intertropical regions for approximately 50 years with a particular focus on entomoparasitological aspects of vector-borne diseases. ORSTOM's close collaboration with TDR since the TDR Special Program was launched in 1975 has led to 1) improved knowledge about various aspects of trypanosomiasis that allowed identification of ways to control the epidemic; 2) reappraisal of the taxonomy of the parasitic protozoa responsible for Chagas disease and leishmaniasis; 3) improvements in the strategy to fight malaria; 4) assessment of the efficacy of ivermectin as a form of mass treatment for onchocerciasis; 5) improved knowledge about dracunculiasis that contributed to an eradication campaign; 6) expansion of the scope of biological control of bancroftian filariasis and other parasites; and 7) improved knowledge about ways to control two schistosome species. ORSTOM also participated in a training and structural enhancement initiative that resulted in creation of the Boake Medical and Veterinary Entomology Training Center. ORSTOM is currently undergoing a complete restructuring to respond to changes in international tropical disease research and to changing priorities that focus on vector-borne diseases, nutrition, AIDS, and health systems.

  13. Spatial fluctuations of the intergalactic temperature-density relation after hydrogen reionization

    NASA Astrophysics Data System (ADS)

    Keating, Laura C.; Puchwein, Ewald; Haehnelt, Martin G.

    2018-07-01

    The thermal state of the post-reionization IGM is sensitive to the timing of reionization and the nature of the ionizing sources. We have modelled here the thermal state of the IGM in cosmological radiative transfer simulations of a realistic, extended, spatially inhomogeneous hydrogen reionization process, carefully calibrated with Ly α forest data. We compare these with cosmological simulations run using a spatially homogeneous ionizing background. The simulations with a realistic growth of ionized regions and a realistic spread in reionization redshifts show, as expected, significant spatial fluctuations in the temperature-density relation (TDR) of the post-reionization IGM. The most recently ionized regions are hottest and exhibit a flatter TDR. In simulations consistent with the average TDR inferred from Ly α forest data, these spatial fluctuations have a moderate but noticeable effect on the statistical properties of the Ly α opacity of the IGM at z ˜ 4-6. This should be taken into account in accurate measurements of the thermal properties of the IGM and the free-streaming of dark matter from Ly α forest data in this redshift range. The spatial variations of the TDR predicted by our simulations are, however, smaller by about a factor of 2 than would be necessary to explain the observed large spatial opacity fluctuations on large (≥50 h-1 comoving Mpc) scales atz ≳ 5.5.

  14. [Minor strut fracture of the Björk-Shiley mitral valve].

    PubMed

    Sugita, T; Yasuda, R; Watarida, S; Onoe, M; Tabata, R; Mori, A

    1990-06-01

    In May, 1982, a 49-year-old man underwent mitral valve replacement (MVR) in our hospital with a 31 mm Björk-Shiley prosthesis for mitral regurgitation. He had been doing well until his episode of palpitation and dyspnea of sudden onset, and was transferred to our ICU with severe cardiogenic shock in Aug, 1986. Chest X-ray film revealed pulmonary edema and breakage of the valve with migration of the disc and the minor strut of the prosthesis. He was operated upon 5 hours after the onset of his complaints. The minor strut was removed from the left upper pulmonary vein and mitral valve re-replacement was done with a 29 mm Björk-Shiley Monostrut valve. The disc which had dislocated into the abdominal aorta was also recovered on the twenty-third post operative day. His postoperative course was uneventful. Immediate diagnosis and subsequent re-operation is absolute indication for rescue from acute cardiac failure due to mechanical failure of any prosthetic valve.

  15. Parametric modeling of the intervertebral disc space in 3D: application to CT images of the lumbar spine.

    PubMed

    Korez, Robert; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-10-01

    Gradual degeneration of intervertebral discs of the lumbar spine is one of the most common causes of low back pain. Although conservative treatment for low back pain may provide relief to most individuals, surgical intervention may be required for individuals with significant continuing symptoms, which is usually performed by replacing the degenerated intervertebral disc with an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study, we propose a method for parametric modeling of the intervertebral disc space in three dimensions (3D) and show its application to computed tomography (CT) images of the lumbar spine. The initial 3D model of the intervertebral disc space is generated according to the superquadric approach and therefore represented by a truncated elliptical cone, which is initialized by parameters obtained from 3D models of adjacent vertebral bodies. In an optimization procedure, the 3D model of the intervertebral disc space is incrementally deformed by adding parameters that provide a more detailed morphometric description of the observed shape, and aligned to the observed intervertebral disc space in the 3D image. By applying the proposed method to CT images of 20 lumbar spines, the shape and pose of each of the 100 intervertebral disc spaces were represented by a 3D parametric model. The resulting mean (±standard deviation) accuracy of modeling was 1.06±0.98mm in terms of radial Euclidean distance against manually defined ground truth points, with the corresponding success rate of 93% (i.e. 93 out of 100 intervertebral disc spaces were modeled successfully). As the resulting 3D models provide a description of the shape of intervertebral disc spaces in a complete parametric form, morphometric analysis was straightforwardly enabled and allowed the computation of the corresponding heights, widths and volumes, as well as of other geometric features that in detail describe the shape of intervertebral disc spaces. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Accuracy of CT parameters for assessment of tumour size and aggressiveness in lung adenocarcinoma with bronchoalveolar elements.

    PubMed

    Bhure, U N; Lardinois, D; Kalff, V; Hany, T F; Soltermann, A; Seifert, B; Steinert, H C

    2010-10-01

    Accurate determination of tumour size in lung adenocarcinoma with bronchoalveolar features (BAC) is important for the determination of TNM (tumour, nodes, metastasis) scores used in staging, prognosis and therapy response assessment. However, tumour sizes derived using lung window (LW) CT or soft-tissue/mediastinal window (MW) CT often give different results. This study examines which measurement correlates best with actual tumour size and which best identifies advanced disease. This retrospective study included 43 BAC patients who underwent surgical resection with mediastinal lymphadenectomy <4 weeks post CT scan. The largest unidimensional tumour diameter on each CT window was compared with actual histopathological tumour size (HP). LW, MW and HP size measurements and a recently described CT parameter - the modified tumour shadow disappearance rate (mTDR) = (1 - [MW/LW]) - were then used to determine which parameter best discriminated between the presence or absence of advanced disease. There was no difference between HP and LW sizes, but MW significantly underestimated HP size (p<0.0001). Unlike MW (p = 0.01) and mTDR (p = 0.001), neither HP (p = 0.14) nor LW (p = 0.10) distinguished between patients with or without advanced disease. On receiver operating characteristic (ROC) analysis at a cut-off of ≤0.13, the sensitivity and specificity of mTDR for detecting advanced disease were 69% and 89%, respectively. In patients with tumours ≤3 cm, only mTDR remained a significant predictor of advanced disease (p = 0.017), with best cut-off at ≤0.20, giving a sensitivity and specificity of 71% and 94%, respectively. MW better predicts advanced disease than LW and might also need to be recorded for RECIST (response evaluation criteria in solid tumours) assessment for T staging of BAC; however, mTDR appears to be an even better predictor and should also be used.

  17. Detection of an organic-non volatile compound in variable-contaminated volcanic soil samples via Time Domain Reflectometry (TDR) technique: Preliminary results

    NASA Astrophysics Data System (ADS)

    comegna, alessandro; coppola, antonio; dragonetti, giovanna; chaali, nesrine; sommella, angelo

    2014-05-01

    Hydrocarbons may be present in soils as non-aqueous phase liquids (NAPLs), which means that these organic compounds, exist as a separate and immiscible phase with respect to water and air commonly present in the soil. NAPLs, which can be accidentally introduced in the environment (for example by waste disposal sites, industrial spills, gasoline stations, etc), constitutes a serious geo-environmental problem, given the toxicity level and the high mobility. Time domain reflectometry (TDR) has became, over several decades, an important technique for water estimation in soils. In order to expand the potentiality of the TDR technique, the main objective of this study is to explore the capacity of dielectric response to detect the presence of NAPLs in volcanic soils. In laboratory, soil samples were oven dried at 105° C and passed through a 2 mm sieve. Known quantities of soil, water and NAPL (corn oil, a non-volatile and non-toxic organic compound) were mixed and repacked into plastic cylinders (16 cm high and 9.5 cm in diameter); in order to obtain forty different volumetric combinations of water and oil (i.e. θfg = θwater + θNAPL), with θNAPL varying from 0.05 to 0.40 by 0.05 cm3/cm3 increments. Data collected were employed to implement a multiphase mixing model which permitted conversion from a dielectric permittivity domain into a θf domain and vice versa. The results of this study show that, the TDR device is NAPL-sensitive, especially for θf values greater than 0.20. Further works will be built on this initial study, concentrating on improving the dielectric response-database, in order to: i) enhancing the model efficiency in terms of NAPL capability detention, and ii) validating the developed TDR interpretation tool with field results.

  18. Is the behavior of disc replacement adjacent to fusion affected by the location of the fused level in hybrid surgery?

    PubMed

    Wu, Ting-Kui; Meng, Yang; Wang, Bei-Yu; Hong, Ying; Rong, Xin; Ding, Chen; Chen, Hua; Liu, Hao

    2018-04-27

    Hybrid surgery (HS), consisting of cervical disc arthroplasty (CDA) at the mobile level, along with anterior cervical discectomy and fusion at the spondylotic level, could be a promising treatment for patients with multilevel cervical degenerative disc disease (DDD). An advantage of this technique is that it uses an optimal procedure according to the status of each level. However, information is lacking regarding the influence of the relative location of the replacement and the fusion segment in vivo. We conducted the present study to investigate whether the location of the fusion affected the behavior of the disc replacement and adjacent segments in HS in vivo. This is an observational study. The numbers of patients in the arthroplasty-fusion (AF) and fusion-arthroplasty (FA) groups were 51 and 24, respectively. The Japanese Orthopedic Association (JOA), Neck Disability Index (NDI), and Visual Analog Scale (VAS) scores were evaluated. Global and segmental lordosis, the range of motion (ROM) of C2-C7, and the operated and adjacent segments were measured. Fusion rate and radiological changes at adjacent levels were observed. Between January 2010 and July 2016, 75 patients with cervical DDD at two contiguous levels undergoing a two-level HS were retrospectively reviewed. The patients were divided into AF and FA groups according to the locations of the disc replacement. Clinical outcomes were evaluated according to the JOA, NDI, and VAS scores. Radiological parameters, including global and segmental lordosis, the ROM of C2-C7, the operated and adjacent segments, and complications, were also evaluated. Although the JOA, NDI, and VAS scores were improved in both the AF and the FA groups, no significant differences were found between the two groups at any follow-up point. Both groups maintained cervical lordosis, but no difference was found between the groups. Segmental lordosis at the fusion segment was significantly improved postoperatively (p<.001), whereas it was maintained at the arthroplasty segment. The ROM of C2-C7 was significantly decreased in both groups postoperatively (AF p=.001, FA p=.014), but no difference was found between the groups. The FA group exhibited a non-significant improvement in ROM at the arthroplasty segment. The ROM adjacent to the arthroplasty segment was increased, although not significantly, whereas the ROM adjacent to the fusion segment was significantly improved after surgery in both groups (p<.001). Fusion was achieved in all patients. No significant difference in complications was found between the groups. In HS, cephalic or caudal fusion segments to the arthroplasty segment did not affect the clinical outcomes and the behavior of CDA. However, the ROM of adjacent segments was affected by the location of the fusion segment; segments adjacent to fusion segments had greater ROMs than segments adjacent to arthroplasty segments. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Cervical disc arthroplasty: Pros and cons

    PubMed Central

    Moatz, Bradley; Tortolani, P. Justin

    2012-01-01

    Background: Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. Methods: This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Results: Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Conclusion: Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing. PMID:22905327

  20. Method for evaluation of laboratory craters using crater detection algorithm for digital topography data

    NASA Astrophysics Data System (ADS)

    Salamunićcar, Goran; Vinković, Dejan; Lončarić, Sven; Vučina, Damir; Pehnec, Igor; Vojković, Marin; Gomerčić, Mladen; Hercigonja, Tomislav

    In our previous work the following has been done: (1) the crater detection algorithm (CDA) based on digital elevation model (DEM) has been developed and the GT-115225 catalog has been assembled [GRS, 48 (5), in press, doi:10.1109/TGRS.2009.2037750]; and (2) the results of comparison between explosion-induced laboratory craters in stone powder surfaces and GT-115225 have been presented using depth/diameter measurements [41stLPSC, Abstract #1428]. The next step achievable using the available technology is to create 3D scans of such labo-ratory craters, in order to compare different properties with simple Martian craters. In this work, we propose a formal method for evaluation of laboratory craters, in order to provide objective, measurable and reproducible estimation of the level of achieved similarity between these laboratory and real impact craters. In the first step, the section of MOLA data for Mars (or SELENE LALT for Moon) is replaced with one or several 3D-scans of laboratory craters. Once embedment was done, the CDA can be used to find out whether this laboratory crater is similar enough to real craters, as to be recognized as a crater by the CDA. The CDA evaluation using ROC' curve represents how true detection rate (TDR=TP/(TP+FN)=TP/GT) depends on the false detection rate (FDR=FP/(TP+FP)). Using this curve, it is now possible to define the measure of similarity between laboratory and real impact craters, as TDR or FDR value, or as a distance from the bottom-right origin of the ROC' curve. With such an approach, the reproducible (formally described) method for evaluation of laboratory craters is provided.

  1. TTK Chitra tilting disc heart valve model TC2: An assessment of fatigue life and durability.

    PubMed

    Subhash, N N; Rajeev, Adathala; Sujesh, Sreedharan; Muraleedharan, C V

    2017-08-01

    Average age group of heart valve replacement in India and most of the Third World countries is below 30 years. Hence, the valve for such patients need to be designed to have a service life of 50 years or more which corresponds to 2000 million cycles of operation. The purpose of this study was to assess the structural performance of the TTK Chitra tilting disc heart valve model TC2 and thereby address its durability. The TC2 model tilting disc heart valves were assessed to evaluate the risks connected with potential structural failure modes. To be more specific, the studies covered the finite element analysis-based fatigue life prediction and accelerated durability testing of the tilting disc heart valves for nine different valve sizes. First, finite element analysis-based fatigue life prediction showed that all nine valve sizes were in the infinite life region. Second, accelerated durability test showed that all nine valve sizes remained functional for 400 million cycles under experimental conditions. The study ensures the continued function of TC2 model tilting disc heart valves over duration in excess of 50 years. The results imply that the TC2 model valve designs are structurally safe, reliable and durable.

  2. Time-Domain Reflectometry for Tamper Indication in Unattended Monitoring Systems for Safeguards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Moore, David E.

    2014-12-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended, remotely monitored measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Pacific Northwest National Laboratory (PNNL) leads a collaboration that is exploring various tamper-indicating (TI) measures that could help to address some of the long-standing detector and data-transmission authentication challenges with IAEA’s unattended systems. PNNL is investigating the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory goldmore » standard to which field-deployable options can be compared, and (2) a low-cost commercially available spread-spectrum TDR technology as one option for field implementation. This report describes PNNL’s progress and preliminary findings from the first year of the study, and describes the path forward.« less

  3. Early turbulence in von Karman swirling flow of polymer solutions

    NASA Astrophysics Data System (ADS)

    Burnishev, Yuri; Steinberg, Victor

    2015-01-01

    We present quantitative experimental results on the transition to early turbulence in von Karman swirling flow of water- and water-sugar-based polymer solutions compared to the transition to turbulence in their Newtonian solvents by measurements of solely global quantities as torque Γ(t) and pressure p(t) with large statistics as a function of Re. For the first time the transition values of Re_c\\textit{turb} to fully developed turbulence and turbulent drag reduction regime Re_c\\textit{TDR} are obtained as functions of elasticity El by using the solvents with different viscosities and polymer concentrations ϕ. Two scaling regions for fundamental turbulent characteristics are identified and they correspond to the turbulent and TDR regimes. Both Re_c\\textit{turb} and Re_c\\textit{TDR} are found via the dependence of the friction coefficient Cf and Cp, defined through scaled average torque \\barΓ and rms pressure fluctuations p\\textit{rms} , respectively, on Re for different El and ϕ and via the limits of the two scaling regions.

  4. Rock Slide Monitoring by Using TDR Inclinometers

    NASA Astrophysics Data System (ADS)

    Drusa, Marián; Bulko, Roman

    2016-12-01

    The geotechnical monitoring of the slope deformations is widespread at present time. In many geological localities and civil engineering construction areas, monitoring is a unique tool for controlling of negative factors and processes, also inform us about actual state of rock environment or interacting structures. It is necessary for risk assessment. In our case, geotechnical monitoring is controlling rockslide activity around in the future part of motorway. The construction of new highway route D1 from Bratislava to Košice crosses the territory which is affected by a massive rockslide close to Kraľovany village. There was a need to monitor the activity of a large unstable rockslide with deep shear planes. In this case of underground movement activity, the Department of Geotechnics of the University of Žilina installed inclinometers at the unstable area which worked on Time Domain Reflectometry (TDR) principle. Based on provided measurements, effectivity and suitability of TDR inclinometers for monitoring of deep underground movement activity is demonstrated.

  5. A comparison of petrophysical data inputs for establishing time-depth relationships: a guide for future drilling expeditions

    NASA Astrophysics Data System (ADS)

    Boaga, J.; Sauermilch, I.; Mateo, Z. R. P.

    2017-12-01

    Time-depth relationships (TDR) are crucial in correlating drillhole and core information to seismic reflection profiles, for accurate resource estimation, scientific interpretation and to guide drilling operations. Conventional seismic time-depth domain conversion utilizes downhole sonic logs (DSI), calibrated using available checkshot data, which are local travel times from the surface to a particular depth. Scientific drilling programs (ODP and IODP) also measure P-wave velocity (PWL or C) on recovered core samples. Only three percent of all ODP and IODP sites record all three velocity measurements, however this information can be instructive as sometimes these data input show dissimilar TDR. These representative sites provide us with an opportunity to perform a comparative analysis highlighting the differences and similarities of TDRs derived from checkshot, downhole, and laboratory measurements. We then discuss the impact of lithology, stratigraphy, water column and other petrophysical properties in the predictive accuracy of TDR calculations, in an effort to provide guidance for future drilling and coring expeditions.

  6. Differential CLE peptide perception by plant receptors implicated from structural and functional analyses of TDIF-TDR interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhijie; Chakraborty, Sayan; Xu, Guozhou

    Tracheary Element Differentiation Inhibitory Factor (TDIF) belongs to the family of post-translationally modified CLE (CLAVATA3/embryo surrounding region (ESR)-related) peptide hormones that control root growth and define the delicate balance between stem cell proliferation and differentiation in SAM (shoot apical meristem) or RAM (root apical meristem). In Arabidopsis, Tracheary Element Differentiation Inhibitory Factor Receptor (TDR) and its ligand TDIF signaling pathway is involved in the regulation of procambial cell proliferation and inhibiting its differentiation into xylem cells. Here we present the crystal structures of the extracellular domains (ECD) of TDR alone and in complex with its ligand TDIF resolved at 2.65more » Åand 2.75 Å respectively. These structures provide insights about the ligand perception and specific interactions between the CLE peptides and their cognate receptors. Our in vitro biochemical studies indicate that the interactions between the ligands and the receptors at the C-terminal anchoring site provide conserved binding. While the binding interactions occurring at the N-terminal anchoring site dictate differential binding specificities between different ligands and receptors. Our studies will open different unknown avenues of TDR-TDIF signaling pathways that will enhance our knowledge in this field highlighting the receptor ligand interaction, receptor activation, signaling network, modes of action and will serve as a structure function relationship model between the ligand and the receptor for various similar leucine-rich repeat receptor-like kinases (LRR-RLKs).« less

  7. Dynamic prognostication using conditional survival analysis for patients with operable lung adenocarcinoma

    PubMed Central

    Kim, Wooil; Lee, Ho Yun; Jung, Sin-Ho; Woo, Min-Ah; Kim, Hong Kwan; Choi, Yong Soo; Kim, Jhingook; Zo, Jae Ill; Shim, Young Mog; Han, Joungho; Jeong, Ji Yun; Choi, Joon Young; Lee, Kyung Soo

    2017-01-01

    Purpose To evaluate conditional survival among patients with surgically resected stage I-IIIa lung adenocarcinoma and identify changes in prognostic contributions for various prognostic factors over time. Patients and Methods We performed conditional survival analysis at each t0 (=0, 1, 2, 3, 4, 5 years) for 723 consecutive patients who underwent surgical resection for lung adenocarcinoma, stratified by various clinico-demographic features, as well as pathologic and imaging (tumor-shadow disappearance ratio [TDR] on CT and maximum standardized uptake value [SUVmax] on PET) characteristics. Uni- and multivariableCox regression analyses were performed to evaluate relationships between those variables and conditional survival. Results Three-year conditional overall survival (OS) and disease-free survival (DFS) were 92.12% and 75.51% at baseline, but improved steadily up to 98.33% and 95.95% at 5 years after surgery. In contrast to demographic factors, pathologic (stage, subtype, pathologic grade and differentiation) and radiologic factors (TDR and SUVmax) maintained a statistically significant association with subseqeunt 3-year OS until 3 years after surgery. According to the multivariableanalysis, high SUVmax and low TDR value were independent predictors of subsequent 3-year OS and DFS at baseline, 1 and 2 years after surgery, respectively. Conclusion Our findings based on CS provide theoretical background for clinicians to plan longer period of surveillance following lung adenocarcinoma resection in survivors with preoperatively high SUVmax and low TDR on PET-CT and chest CT, respectively. PMID:27793026

  8. Effective crop evapotranspiration measurement using time-domain reflectometry technique in a sub-humid region

    NASA Astrophysics Data System (ADS)

    Srivastava, R. K.; Panda, R. K.; Halder, Debjani

    2017-08-01

    The primary objective of this study was to evaluate the performance of the time-domain reflectometry (TDR) technique for daily evapotranspiration estimation of peanut and maize crop in a sub-humid region. Four independent methods were used to estimate crop evapotranspiration (ETc), namely, soil water balance budgeting approach, energy balance approach—(Bowen ratio), empirical methods approach, and Pan evaporation method. The soil water balance budgeting approach utilized the soil moisture measurement by gravimetric and TDR method. The empirical evapotranspiration methods such as combination approach (FAO-56 Penman-Monteith and Penman), temperature-based approach (Hargreaves-Samani), and radiation-based approach (Priestley-Taylor, Turc, Abetw) were used to estimate the reference evapotranspiration (ET0). The daily ETc determined by the FAO-56 Penman-Monteith, Priestley-Taylor, Turc, Pan evaporation, and Bowen ratio were found to be at par with the ET values derived from the soil water balance budget; while the methods Abetw, Penman, and Hargreaves-Samani were not found to be ideal for the determination of ETc. The study illustrates the in situ applicability of the TDR method in order to make it possible for a user to choose the best way for the optimum water consumption for a given crop in a sub-humid region. The study suggests that the FAO-56 Penman-Monteith, Turc, and Priestley-Taylor can be used for the determination of crop ETc using TDR in comparison to soil water balance budget.

  9. Use of soil moisture probes to estimate ground water recharge at an oil spill site

    USGS Publications Warehouse

    Delin, G.N.; Herkelrath, W.N.

    2005-01-01

    Soil moisture data collected using an automated data logging system were used to estimate ground water recharge at a crude oil spill research site near Bemidji, Minnesota. Three different soil moisture probes were tested in the laboratory as well as the field conditions of limited power supply and extreme weather typical of northern Minnesota: a self-contained reflectometer probe, and two time domain reflectometry (TDR) probes, 30 and 50 cm long. Recharge was estimated using an unsaturated zone water balance method. Recharge estimates for 1999 using the laboratory calibrations were 13 to 30 percent greater than estimates based on the factory calibrations. Recharge indicated by the self-contained probes was 170 percent to 210 percent greater than the estimates for the TDR probes regardless of calibration method. Results indicate that the anomalously large recharge estimates for the self-contained probes are not the result of inaccurate measurements of volumetric moisture content, but result from the presence of crude oil, or bore-hole leakage. Of the probes tested, the 50 cm long TDR probe yielded recharge estimates that compared most favorably to estimates based on a method utilizing water table fluctuations. Recharge rates for this probe represented 24 to 27 percent of 1999 precipitation. Recharge based on the 30 cm long horizontal TDR probes was 29 to 37 percent of 1999 precipitation. By comparison, recharge based on the water table fluctuation method represented about 29 percent of precipitation. (JAWRA) (Copyright ?? 2005).

  10. The Yucatan Minipig Temporomandibular Joint Disc Structure-Function Relationships Support Its Suitability for Human Comparative Studies.

    PubMed

    Vapniarsky, Natalia; Aryaei, Ashkan; Arzi, Boaz; Hatcher, David C; Hu, Jerry C; Athanasiou, Kyriacos A

    2017-11-01

    Frequent involvement of the disc in temporomandibular joint (TMJ) disorders warrants attempts to tissue engineer TMJ disc replacements. Physiologically, a great degree of similarity is seen between humans and farm pigs (FPs), but the pig's rapid growth confers a significant challenge for in vivo experiments. Minipigs have a slower growth rate and are smaller than FPs, but minipig TMJ discs have yet to be fully characterized. The objective of this study was to determine the suitability of the minipig for TMJ studies by extensive structural and functional characterization. The properties of minipig TMJ discs closely reproduced previously reported morphological, biochemical, and biomechanical values of human and FP discs. The width/length dimension ratio of the minipig TMJ disc was 1.95 (1.69 for human and 1.94 for FP). The biochemical evaluation revealed, on average per wet weight, 24.3% collagen (22.8% for human and 24.9% for FP); 0.8% glycosaminoglycan (GAG; 0.5% for human and 0.4% for FP); and 0.03% DNA (0.008% for human and 0.02% for FP). Biomechanical testing revealed, on average, compressive relaxation modulus of 50 kPa (37 kPa for human and 32 kPa for FP), compressive instantaneous modulus of 1121 kPa (1315 kPa for human and 1134 kPa for FP), and coefficient of viscosity of 13 MPa·s (9 MPa·s for human and 3 MPa·s for FP) at 20% strain. These properties also varied topographically in accordance to those of human and FP TMJ discs. Anisotropy, quantified by bidirectional tensile testing and histology, again was analogous among minipig, human, and FP TMJ discs. The minipig TMJ's ginglymoarthrodial nature was verified through cone beam computer tomography. Collectively, the similarities between minipig and human TMJ discs support the use of minipig as a relevant model for TMJ research; considering the practical advantages conferred by its growth rate and size, the minipig may be a preferred model over FP.

  11. Monitoring moisture storage in trees using time domain reflectometry

    USGS Publications Warehouse

    Constantz, J.; Murphy, F.

    1990-01-01

    Laboratory and field tests were performed to examine the feasibility of using time domain reflectometry (TDR) to monitor changes in the moisture storage of the woody parts of trees. To serve as wave guides for the TDR signal, pairs of stainless steel rods (13 cm long, 0.32 cm in diameter, and 2.5 cm separation) were driven into parallel pilot holes drilled into the woody parts of trees, and a cable testing oscilloscope was used to determine the apparent dielectric constant. A laboratory calibration test was performed on two sapwood samples, so that the relation between the volumetric water content and the apparent dielectric constant of the sapwood could be determined over a range of water contents. The resulting calibration curve for these sapwood samples was significantly different than the general calibration curve used for soils, showing a smaller change in the apparent dielectric constant for a given change in the volumetric water content than is typical for soils. The calibration curve was used to estimate the average volumetric water content to a depth of 13 cm in living trees. One field experiment was conducted on an English walnut tree (Juglans regia) with a diameter of 40 cm, growing in a flood-irrigated orchard on a Hanford sandy loam near Modesto, California (U.S.A.). Rods were driven into the tree at about 50 cm above the soil surface and monitored hourly for the month of August, 1988. The moisture content determined by TDR showed a gradual decrease from 0.44 to 0.42 cm3 cm-3 over a two week period prior to flood irrigation, followed by a rapid rise to 0.47 cm3 cm-3 over a four day period after irrigation, then again a gradual decline approaching the next irrigation. A second field experiment was made on ten evergreen and deciduous trees with diameters ranging from 30 to 120 cm, growing in the foothills of the Coast Range of central California. Rods were driven into each tree at 50 to 100 cm above the soil surface and monitored on a biweekly to monthly basis for over a year. Most trees showed an early spring maximum in moisture content determined by TDR associated with leaf growth, and a late summer minimum in moisture content associated with the end of the dry season. Moisture contents ranged from 0.20 to 0.70 cm3 cm-3, with an annual percentage change in moisture of 15% to 70% depending on species and environmental conditions. A final field test was performed in northern New Mexico (U.S.A.) to examine the effect of trunk freezing on TDR measurements. This test confirmed that freezing conditions were recorded as a total loss of liquid water by the TDR method. These results suggest that further TDR calibration for wood, plus some understanding of the relation between tree moisture and physiological stress could be useful to several disciplines, ranging from irrigation scheduling to watershed management to forest ecology. ?? 1990.

  12. Analysis of Coaxial Soil Cell in Reflection and Transmission

    PubMed Central

    Pelletier, Mathew G.; Viera, Joseph A.; Schwartz, Robert C.; Evett, Steven R.; Lascano, Robert J.; McMichael, Robert L.

    2011-01-01

    Accurate measurement of moisture content is a prime requirement in hydrological, geophysical and biogeochemical research as well as for material characterization and process control. Within these areas, accurate measurements of the surface area and bound water content is becoming increasingly important for providing answers to many fundamental questions ranging from characterization of cotton fiber maturity, to accurate characterization of soil water content in soil water conservation research to bio-plant water utilization to chemical reactions and diffusions of ionic species across membranes in cells as well as in the dense suspensions that occur in surface films. In these bound water materials, the errors in the traditional time-domain-reflectometer, “TDR”, exceed the range of the full span of the material’s permittivity that is being measured. Thus, there is a critical need to re-examine the TDR system and identify where the errors are to direct future research. One promising technique to address the increasing demands for higher accuracy water content measurements is utilization of electrical permittivity characterization of materials. This technique has enjoyed a strong following in the soil-science and geological community through measurements of apparent permittivity via time-domain-reflectometery as well in many process control applications. Recent research however, is indicating a need to increase the accuracy beyond that available from traditional TDR. The most logical pathway then becomes a transition from TDR based measurements to network analyzer measurements of absolute permittivity that will remove the adverse effects that high surface area soils and conductivity impart onto the measurements of apparent permittivity in traditional TDR applications. This research examines the theoretical basis behind the coaxial probe, from which the modern TDR probe originated from, to provide a basis on which to perform absolute permittivity measurements. The research reveals currently utilized formulations in accepted techniques for permittivity measurements which violate the underlying assumptions inherent in the basic models due to the TDR acting as an antenna by radiating energy off the end of the probe, rather than returning it back to the source as is the current assumption. To remove the effects of radiation from the experimental results obtain herein, this research utilized custom designed coaxial probes of various diameters and probe lengths by which to test the coaxial cell measurement technique for accuracy in determination of absolute permittivity. In doing so, the research reveals that the basic models available in the literature all omitted a key correction factor that is hypothesized by this research as being most likely due to fringe capacitance. To test this theory, a Poisson model of a coaxial cell was formulated to calculate the effective extra length provided by the fringe capacitance which is then used to correct the experimental results such that experimental measurements utilizing differing coaxial cell diameters and probe lengths, upon correction with the Poisson model derived correction factor, all produce the same results thereby lending support for the use of an augmented measurement technique, described herein, for measurement of absolute permittivity, as opposed to the traditional TDR measurement of apparent permittivity. PMID:22163757

  13. Measurements of effective non-rainfall in soil with the use of time-domain reflectometry technique

    NASA Astrophysics Data System (ADS)

    Nakonieczna, Anna; Kafarski, Marcin; Wilczek, Andrzej; Szypłowska, Agnieszka; Skierucha, Wojciech

    2014-05-01

    The non-rainfall vectors are fog, dew, hoarfrost and vapour adsorption directly from the atmosphere. The measurements of the amount of water supplied to the soil due to their temporary existence are essential, because in dry areas such water uptake can exceed that of rainfall. Although several devices and methods were proposed for estimating the effective non-rainfall input into the soil, the measurement standard has not yet been established. This is mainly due to obstacles in measuring small water additions to the medium, problems with taking readings in actual soil samples and atmospheric disturbances during their course in natural environment. There still exists the need for automated devices capable of measuring water deposition on real-world soil surfaces, whose resolution is high enough to measure the non-rainfall intensity and increase rate, which are usually very low. In order to achieve the desirable resolution and accuracy of the effective non-rainfall measurements the time-domain reflectometry (TDR) technique was employed. The TDR sensor designed and made especially for the purpose was an untypical waveguide. It consisted of a base made of laminate covered with copper, which served as a bottom of a cuboidal open container in which the examined materials were placed, and a copper signal wire placed on the top of the container. The wire adhered along its entire length to the tested material in order to eliminate the formation of air gaps between the two, what enhanced the accuracy of the measurements. The tested porous materials were glass beads, rinsed sand and three soil samples, which were collected in south-eastern Poland. The diameter ranges of their constituent particles were measured with the use of the laser diffraction technique. The sensor filled with the wetted material was placed on a scale and connected to the TDR meter. The automated readings of mass and TDR time were collected simultaneously every minute. The TDR time was correlated with the mass loss, which was a measure of the amount of water that evaporated from the porous medium. Preliminary measurements demonstrated that the temperature control is dispensable for the conducted laboratory studies, because small temperature variations do not influence the results noticeably. However, field measurements would definitely require advanced temperature calibration. The aim of the research was to test the designed sensor for the effective non-rainfall intensity measurements in actual soil samples. It turned out that the device is highly sensitive to the amount of water present in the investigated medium. The geometry of the sensor allowed obtaining satisfactory resolution, which in the case of soil samples did not exceed 0.015 mm of water. Moreover, the direct translation of the TDR time into the water amount present in the examined media is straightforward and workable among the tested materials, which is the main advantage of the presented measurement method. Hence, both the applied TDR technique and the construction of the sensor proved to be adequate for the planned measurements of the effective non-rainfall intensity.

  14. Monitoring moisture storage in trees using time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Constantz, Jim; Murphy, Fred

    1990-11-01

    Laboratory and field tests were performed to examine the feasibility of using time domain reflectometry (TDR) to monitor changes in the moisture storage of the woody parts of trees. To serve as wave guides for the TDR signal, pairs of stainless steel rods (13 cm long, 0.32 cm in diameter, and 2.5 cm separation) were driven into parallel pilot holes drilled into the woody parts of trees, and a cable testing oscilloscope was used to determine the apparent dielectric constant. A laboratory calibration test was performed on two sapwood samples, so that the relation between the volumetric water content and the apparent dielectric constant of the sapwood could be determined over a range of water contents. The resulting calibration curve for these sapwood samples was significantly different than the general calibration curve used for soils, showing a smaller change in the apparent dielectric constant for a given change in the volumetric water content than is typical for soils. The calibration curve was used to estimate the average volumetric water content to a depth of 13 cm in living trees. One field experiment was conducted on an English walnut tree ( Juglans regia) with a diameter of 40 cm, growing in a flood-irrigated orchard on a Hanford sandy loam near Modesto, California (U.S.A.). Rods were driven into the tree at about 50 cm above the soil surface and monitored hourly for the month of August, 1988. The moisture content determined by TDR showed a gradual decrease from 0.44 to 0.42 cm 3 cm -3 over a two week period prior to flood irrigation, followed by a rapid rise to 0.47 cm 3 cm -3 over a four day period after irrigation, then again a gradual decline approaching the next irrigation. A second field experiment was made on ten evergreen and deciduous trees with diameters ranging from 30 to 120 cm, growing in the foothills of the Coast Range of central California. Rods were driven into each tree at 50 to 100 cm above the soil surface and monitored on a biweekly to monthly basis for over a year. Most trees showed an early spring maximum in moisture content determined by TDR associated with leaf growth, and a late summer minimum in moisture content associated with the end of the dry season. Moisture contents ranged from 0.20 to 0.70 cm 3 cm -3, with an annual percentage change in moisture of 15% to 70% depending on species and environmental conditions. A final field test was performed in northern New Mexico (U.S.A.) to examine the effect of trunk freezing on TDR measurements. This test confirmed that freezing conditions were recorded as a total loss of liquid water by the TDR method. These results suggest that further TDR calibration for wood, plus some understanding of the relation between tree moisture and physiological stress could be useful to several disciplines, ranging from irrigation scheduling to watershed management to forest ecology.

  15. The First Wave: CD-ROM Adoption in Offices and Libraries: I.

    ERIC Educational Resources Information Center

    Paisley, William; Butler, Matilda

    1988-01-01

    The first of two articles provides an overview of four revolutions in publishing--the movable-type printing press, mechanization, the computer, and optical disc technology. The first phases of CD-ROM development--demonstration of feasibility and testing of replacement functions--are described and compared with earlier technologies. (3 references)…

  16. A Novel Tool for the Assessment Oxidative Stress in Age-Related Macular Degeneration: Thiol/Disulfide Homeostasis Revisited.

    PubMed

    Arıkan Yorgun, Mücella; Toklu, Yasin; Altınkaynak, Hasan; Tanrıverdi, Burak; Ergin, Merve; Biçer, Cemile

    2016-12-01

    To investigate thiol/disulfide status using a novel automated assay in patients with age-related macular degeneration (AMD) compared to age-matched healthy controls. A total of 64 AMD patients [51 (79%) non-exudative, 13 (21%) exudative AMD] and 21 age-matched healthy control subjects were enrolled in this study. Plasma total thiol, native thiol, disulfide levels were measured and native thiol/disulfide ratio (TDR) was calculated using a novel spectrophotometric assay. Patients with AMD had significantly lower levels of total thiol (434.8 ± 7.0 μmol/L vs. 472.2 ± 7.9 μmol/L, p < 0.001), native thiol (393.6 ± 6.5 μmol/L vs. 437.5 ± 7.1 μmol/L, p = 0.004) compared to healthy controls. However, plasma disulfide levels were higher in AMD patients (20.6 ± 0.9 μmol/L vs. 17.3 ± 1.3 μmol/L, p = 0.113) compared to healthy controls. The TDR was not statistically different between the early AMD group and healthy controls (24.2 ± 2.3 vs. 29.5 ± 3.1, p = 0.345). However, intermediate and advanced stage AMD groups had significantly lower levels of TDR compared to healthy controls (21.6 ± 2.6 vs. 29.5 ± 3.1, p = 0.023 and 20.3 ± 1.2 vs. 29.5 ± 3.1, p = 0.005, respectively). Native TDR was significantly lower in patients with exudative and non-exudative AMD (19.9 ± 2.3 vs. 29.5 ± 3.1, p = 0.024 and 21.8 ± 1.14 vs. 29.47 ± 3.1 respectively, p = 0.011). A greater extent of thiol consumption occurred in AMD patients compared to age-matched healthy controls. However, despite the similar levels of total thiol levels between several grades of AMD, the plasma native TDR value was decreased in accordance with the severity of the disease, which reflected the disease grade better.

  17. Fringe Capacitance Correction for a Coaxial Soil Cell

    PubMed Central

    Pelletier, Mathew G.; Viera, Joseph A.; Schwartz, Robert C.; Lascano, Robert J.; Evett, Steven R.; Green, Tim R.; Wanjura, John D.; Holt, Greg A.

    2011-01-01

    Accurate measurement of moisture content is a prime requirement in hydrological, geophysical and biogeochemical research as well as for material characterization and process control. Within these areas, accurate measurements of the surface area and bound water content is becoming increasingly important for providing answers to many fundamental questions ranging from characterization of cotton fiber maturity, to accurate characterization of soil water content in soil water conservation research to bio-plant water utilization to chemical reactions and diffusions of ionic species across membranes in cells as well as in the dense suspensions that occur in surface films. One promising technique to address the increasing demands for higher accuracy water content measurements is utilization of electrical permittivity characterization of materials. This technique has enjoyed a strong following in the soil-science and geological community through measurements of apparent permittivity via time-domain-reflectometry (TDR) as well in many process control applications. Recent research however, is indicating a need to increase the accuracy beyond that available from traditional TDR. The most logical pathway then becomes a transition from TDR based measurements to network analyzer measurements of absolute permittivity that will remove the adverse effects that high surface area soils and conductivity impart onto the measurements of apparent permittivity in traditional TDR applications. This research examines an observed experimental error for the coaxial probe, from which the modern TDR probe originated, which is hypothesized to be due to fringe capacitance. The research provides an experimental and theoretical basis for the cause of the error and provides a technique by which to correct the system to remove this source of error. To test this theory, a Poisson model of a coaxial cell was formulated to calculate the effective theoretical extra length caused by the fringe capacitance which is then used to correct the experimental results such that experimental measurements utilizing differing coaxial cell diameters and probe lengths, upon correction with the Poisson model derived correction factor, all produce the same results thereby lending support and for an augmented measurement technique for measurement of absolute permittivity. PMID:22346601

  18. Calibrating electromagnetic induction conductivities with time-domain reflectometry measurements

    NASA Astrophysics Data System (ADS)

    Dragonetti, Giovanna; Comegna, Alessandro; Ajeel, Ali; Piero Deidda, Gian; Lamaddalena, Nicola; Rodriguez, Giuseppe; Vignoli, Giulio; Coppola, Antonio

    2018-02-01

    This paper deals with the issue of monitoring the spatial distribution of bulk electrical conductivity, σb, in the soil root zone by using electromagnetic induction (EMI) sensors under different water and salinity conditions. To deduce the actual distribution of depth-specific σb from EMI apparent electrical conductivity (ECa) measurements, we inverted the data by using a regularized 1-D inversion procedure designed to manage nonlinear multiple EMI-depth responses. The inversion technique is based on the coupling of the damped Gauss-Newton method with truncated generalized singular value decomposition (TGSVD). The ill-posedness of the EMI data inversion is addressed by using a sharp stabilizer term in the objective function. This specific stabilizer promotes the reconstruction of blocky targets, thereby contributing to enhance the spatial resolution of the EMI results in the presence of sharp boundaries (otherwise smeared out after the application of more standard Occam-like regularization strategies searching for smooth solutions). Time-domain reflectometry (TDR) data are used as ground-truth data for calibration of the inversion results. An experimental field was divided into four transects 30 m long and 2.8 m wide, cultivated with green bean, and irrigated with water at two different salinity levels and using two different irrigation volumes. Clearly, this induces different salinity and water contents within the soil profiles. For each transect, 26 regularly spaced monitoring soundings (1 m apart) were selected for the collection of (i) Geonics EM-38 and (ii) Tektronix reflectometer data. Despite the original discrepancies in the EMI and TDR data, we found a significant correlation of the means and standard deviations of the two data series; in particular, after a low-pass spatial filtering of the TDR data. Based on these findings, this paper introduces a novel methodology to calibrate EMI-based electrical conductivities via TDR direct measurements. This calibration strategy consists of a linear mapping of the original inversion results into a new conductivity spatial distribution with the coefficients of the transformation uniquely based on the statistics of the two original measurement datasets (EMI and TDR conductivities).

  19. So You Want to Be Trustworthy: A Repository's Guide to Taking Reasonable Steps Towards Achieving ISO 16363

    NASA Astrophysics Data System (ADS)

    Stall, S.

    2016-12-01

    To be trustworthy is to be reliable, dependable, honest, principled, ethical, incorruptible, and more. A trustworthy person demonstrates these qualities over time and under all circumstances. A trustworthy repository demonstrates these qualities through the team that manages the repository and its responsible organization. The requirements of a Trusted Digital Repository (TDR) in ISO 16363 can be tough to reach and tough to maintain. Challenges include: limited funds, limited resources and/or skills, and an unclear path to successfully achieve the requirements. The ISO standard defines each requirement separately, but a successful certification recognizes that there are many cross-dependencies among the requirements. Understanding these dependencies leads to a more efficient path towards success. At AGU we recognize that reaching the goal of the TDR ISO standard, or any set of data management objectives defined by an organization, has a better chance at success if the organization clearly knows their current capability, the improvements that are needed, and the best way to make (and maintain) those changes. AGU has partnered with the CMMI® Institute to adapt their Data Management Maturity (DMM)SM model within the Earth and space sciences. Using the DMM, AGU developed a new Data Management Assessment Program aimed at helping data repositories, large and small, domain-specific to general, assess and improve data management practices to meet their goals - including becoming a Trustworthy Digital Repository. The requirements to achieve the TDR ISO standard are aligned to the data management best practices defined in the Data Management Maturity (DMM)SM model. Using the DMM as a process improvement tool in conjunction with the Data Management Assessment method, a team seeking the objective of the TDR ISO standard receives a clear road map to achieving their goal as an outcome of the assessment. Publishers and agencies are beginning to recommend or even require that repositories demonstrate that they are practicing best practices or meeting certain standards. Data preserved in a data facility that is working on achieving a TDR standard will have the level of care desired by the publishing community as well as the science community. Better Data Management results in Better Science.

  20. Temperature-driven adaptation of the bacterial community in peat measured by using thymidine and leucine incorporation.

    PubMed

    Ranneklev, S B; Bååth, E

    2001-03-01

    The temperature-driven adaptation of the bacterial community in peat was studied, by altering temperature to simulate self-heating and a subsequent return to mesophilic conditions. The technique used consisted of extracting the bacterial community from peat using homogenization-centrifugation and measuring the rates of thymidine (TdR) or leucine (Leu) incorporation by the extracted bacterial community at different temperatures. Increasing the peat incubation temperature from 25 degrees C to 35, 45, or 55 degrees C resulted in a selection of bacterial communities whose optimum temperatures for activity correlated to the peat incubation temperatures. Although TdR and Leu incorporations were significantly correlated, the Leu/TdR incorporation ratios were affected by temperature. Higher Leu/TdR incorporation ratios were found at higher temperatures of incubation of the extracted bacterial community. Higher Leu/TdR incorporation ratios were also found for bacteria in peat samples incubated at higher temperatures. The reappearance of the mesophilic community and disappearance of the thermophilic community when the incubation temperature of the peat was shifted down were monitored by measuring TdR incorporation at 55 degrees C (thermophilic activity) and 25 degrees C (mesophilic activity). Shifting the peat incubation temperature from 55 to 25 degrees C resulted in a recovery of the mesophilic activity, with a subsequent disappearance of the thermophilic activity. The availability of substrate for bacterial growth varied over time and among different peat samples. To avoid confounding effects of substrate availability, a temperature adaptation index was calculated. This index consisted of the log(10) ratio of TdR incorporation at 55 and 25 degrees C. The temperature index decreased linearly with time, indicating that no thermophilic activity would be detected by the TdR technique 1 month after the temperature downshift. There were no differences between the slopes of the temperature adaptation indices over time for peat samples incubated at 55 degrees C 3 or 11 days before incubation at 25 degrees C. Thus, different levels of bacterial activity did not affect the temperature-driven adaptation of the bacterial community.

  1. Temperature-Driven Adaptation of the Bacterial Community in Peat Measured by Using Thymidine and Leucine Incorporation

    PubMed Central

    Ranneklev, Sissel Brit; Bååth, Erland

    2001-01-01

    The temperature-driven adaptation of the bacterial community in peat was studied, by altering temperature to simulate self-heating and a subsequent return to mesophilic conditions. The technique used consisted of extracting the bacterial community from peat using homogenization-centrifugation and measuring the rates of thymidine (TdR) or leucine (Leu) incorporation by the extracted bacterial community at different temperatures. Increasing the peat incubation temperature from 25°C to 35, 45, or 55°C resulted in a selection of bacterial communities whose optimum temperatures for activity correlated to the peat incubation temperatures. Although TdR and Leu incorporations were significantly correlated, the Leu/TdR incorporation ratios were affected by temperature. Higher Leu/TdR incorporation ratios were found at higher temperatures of incubation of the extracted bacterial community. Higher Leu/TdR incorporation ratios were also found for bacteria in peat samples incubated at higher temperatures. The reappearance of the mesophilic community and disappearance of the thermophilic community when the incubation temperature of the peat was shifted down were monitored by measuring TdR incorporation at 55°C (thermophilic activity) and 25°C (mesophilic activity). Shifting the peat incubation temperature from 55 to 25°C resulted in a recovery of the mesophilic activity, with a subsequent disappearance of the thermophilic activity. The availability of substrate for bacterial growth varied over time and among different peat samples. To avoid confounding effects of substrate availability, a temperature adaptation index was calculated. This index consisted of the log10 ratio of TdR incorporation at 55 and 25°C. The temperature index decreased linearly with time, indicating that no thermophilic activity would be detected by the TdR technique 1 month after the temperature downshift. There were no differences between the slopes of the temperature adaptation indices over time for peat samples incubated at 55°C 3 or 11 days before incubation at 25°C. Thus, different levels of bacterial activity did not affect the temperature-driven adaptation of the bacterial community. PMID:11229900

  2. Analyses of GPR signals for characterization of ground conditions in urban areas

    NASA Astrophysics Data System (ADS)

    Hong, Won-Taek; Kang, Seonghun; Lee, Sung Jin; Lee, Jong-Sub

    2018-05-01

    Ground penetrating radar (GPR) is applied for the characterization of the ground conditions in urban areas. In addition, time domain reflectometry (TDR) and dynamic cone penetrometer (DCP) tests are conducted for the accurate analyses of the GPR images. The GPR images are acquired near a ground excavation site, where a ground subsidence occurred and was repaired. Moreover, the relative permittivity and dynamic cone penetration index (DCPI) are profiled through the TDR and DCP tests, respectively. As the ground in the urban area is kept under a low-moisture condition, the relative permittivity, which is inversely related to the electromagnetic impedance, is mainly affected by the dry density and is inversely proportional to the DCPI value. Because the first strong signal in the GPR image is shifted 180° from the emitted signal, the polarity of the electromagnetic wave reflected at the dense layer, where the reflection coefficient is negative, is identical to that of the first strong signal. The temporal-scaled GPR images can be accurately converted into the spatial-scaled GPR images using the relative permittivity determined by the TDR test. The distribution of the loose layer can be accurately estimated by using the spatial-scaled GPR images and reflection characteristics of the electromagnetic wave. Note that the loose layer distribution estimated in this study matches well with the DCPI profile and is visually verified from the endoscopic images. This study demonstrates that the GPR survey complemented by the TDR and DCP tests, may be an effective method for the characterization of ground conditions in an urban area.

  3. TDR Targets: a chemogenomics resource for neglected diseases.

    PubMed

    Magariños, María P; Carmona, Santiago J; Crowther, Gregory J; Ralph, Stuart A; Roos, David S; Shanmugam, Dhanasekaran; Van Voorhis, Wesley C; Agüero, Fernán

    2012-01-01

    The TDR Targets Database (http://tdrtargets.org) has been designed and developed as an online resource to facilitate the rapid identification and prioritization of molecular targets for drug development, focusing on pathogens responsible for neglected human diseases. The database integrates pathogen specific genomic information with functional data (e.g. expression, phylogeny, essentiality) for genes collected from various sources, including literature curation. This information can be browsed and queried using an extensive web interface with functionalities for combining, saving, exporting and sharing the query results. Target genes can be ranked and prioritized using numerical weights assigned to the criteria used for querying. In this report we describe recent updates to the TDR Targets database, including the addition of new genomes (specifically helminths), and integration of chemical structure, property and bioactivity information for biological ligands, drugs and inhibitors and cheminformatic tools for querying and visualizing these chemical data. These changes greatly facilitate exploration of linkages (both known and predicted) between genes and small molecules, yielding insight into whether particular proteins may be druggable, effectively allowing the navigation of chemical space in a genomics context.

  4. TDR Targets: a chemogenomics resource for neglected diseases

    PubMed Central

    Magariños, María P.; Carmona, Santiago J.; Crowther, Gregory J.; Ralph, Stuart A.; Roos, David S.; Shanmugam, Dhanasekaran; Van Voorhis, Wesley C.; Agüero, Fernán

    2012-01-01

    The TDR Targets Database (http://tdrtargets.org) has been designed and developed as an online resource to facilitate the rapid identification and prioritization of molecular targets for drug development, focusing on pathogens responsible for neglected human diseases. The database integrates pathogen specific genomic information with functional data (e.g. expression, phylogeny, essentiality) for genes collected from various sources, including literature curation. This information can be browsed and queried using an extensive web interface with functionalities for combining, saving, exporting and sharing the query results. Target genes can be ranked and prioritized using numerical weights assigned to the criteria used for querying. In this report we describe recent updates to the TDR Targets database, including the addition of new genomes (specifically helminths), and integration of chemical structure, property and bioactivity information for biological ligands, drugs and inhibitors and cheminformatic tools for querying and visualizing these chemical data. These changes greatly facilitate exploration of linkages (both known and predicted) between genes and small molecules, yielding insight into whether particular proteins may be druggable, effectively allowing the navigation of chemical space in a genomics context. PMID:22116064

  5. Ethanol-induced analgesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pohorecky, L.A.; Shah, P.

    1987-09-07

    The effect of ethanol (ET) on nociceptive sensitivity was evaluated using a new tail deflection response (TDR) method. The IP injection of ET (0.5 - 1.5 g/kg) produced raid dose-dependent analgesia. Near maximal effect (97% decrease in TDR) was produced with the 1.5 g/kg dose of ET ten minutes after injection. At ninety minutes post-injection there was still significant analgesia. Depression of ET-induced nociceptive sensitivity was partially reversed by a 1 mg/kg dose of naloxone. On the other hand, morphine (0.5 or 5.0 mg/kg IP) did not modify ET-induced analgesia, while 3.0 minutes of cold water swim (known to producemore » non-opioid mediated analgesia) potentiated ET-induced analgesic effect. The 0.5 g/kg dose of ET by itself did not depress motor activity in an open field test, but prevented partially the depression in motor activity produced by cold water swim (CWS). Thus, the potentiation by ET of the depression of the TDR produced by CWS cannot be ascribed to the depressant effects of ET on motor activity. 21 references, 4 figures, 1 table.« less

  6. NASA Hybrid Reflectometer Project

    NASA Technical Reports Server (NTRS)

    Lynch, Dana; Mancini, Ron (Technical Monitor)

    2002-01-01

    Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

  7. High HIV-1 Diversity and Prevalence of Transmitted Drug Resistance Among Antiretroviral-Naive HIV-Infected Pregnant Women from Rio de Janeiro, Brazil.

    PubMed

    Delatorre, Edson; Silva-de-Jesus, Carlos; Couto-Fernandez, José Carlos; Pilotto, Jose H; Morgado, Mariza G

    2017-01-01

    Antiretroviral (ARV) resistance mutations in human immunodeficiency virus type 1 (HIV-1) infection may reduce the efficacy of prophylactic therapy to prevent mother-to-child transmission (PMTCT) and future treatment options. This study evaluated the diversity and the prevalence of transmitted drug resistance (TDR) in protease (PR) and reverse transcriptase (RT) regions of HIV-1 pol gene among 87 ARV-naive HIV-1-infected pregnant women from Rio de Janeiro, Brazil, between 2012 and 2015. The viral diversity comprised HIV-1 subtypes B (67.8%), F1 (17.2%), and C (4.6%); the circulating recombinant forms 12_BF (2.3%), 28/29_BF, 39_BF, 02_AG (1.1% each) and unique recombinants forms (4.5%). The overall prevalence of any TDR was 17.2%, of which 5.7% for nucleoside RT inhibitors, 5.7% for non-nucleoside RT inhibitors, and 8% for PR inhibitors. The TDR prevalence found in this population may affect the virological outcome of the standard PMTCT ARV-regimens, reinforcing the importance of continuous monitoring.

  8. Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces.

    PubMed

    MacBarb, Regina F; Lindsey, Derek P; Bahney, Chelsea S; Woods, Shane A; Wolfe, Mark L; Yerby, Scott A

    2017-01-01

    An aging society and concomitant rise in the incidence of impaired bone health have led to the need for advanced osteoconductive spinal implant surfaces that promote greater biological fixation ( e.g. for interbody fusion cages, sacroiliac joint fusion implants, and artificial disc replacements). Additive manufacturing, i.e. 3D-printing, may improve bone integration by generating biomimetic spinal implant surfaces that mimic bone morphology. Such surfaces may foster an enhanced cellular response compared to traditional implant surfacing processes. This study investigated the response of human osteoblasts to additive manufactured (AM) trabecular-like titanium implant surfaces compared to traditionally machined base material with titanium plasma spray (TPS) coated surfaces, with and without a nanocrystalline hydroxyapatite (HA) coating. For TPS-coated discs, wrought Ti6Al4V ELI was machined and TPS-coating was applied. For AM discs, Ti6Al4V ELI powder was 3D-printed to form a solid base and trabecular-like porous surface. The HA-coating was applied via a precipitation dip-spin method. Surface porosity, pore size, thickness, and hydrophilicity were characterized. Initial cell attachment, proliferation, alkaline phosphatase (ALP) activity, and calcium production of hFOB cells ( n =5 per group) were measured. Cells on AM discs exhibited expedited proliferative activity. While there were no differences in mean ALP expression and calcium production between TPS and AM discs, calcium production on the AM discs trended 48% higher than on TPS discs ( p =0.07). Overall, HA-coating did not further enhance results compared to uncoated TPS and AM discs. Results demonstrate that additive manufacturing allows for controlled trabecular-like surfaces that promote earlier cell proliferation and trends toward higher calcium production than TPS coating. Results further showed that nanocrystalline HA may not provide an advantage on porous titanium surfaces. Additive manufactured porous titanium surfaces may induce a more osteogenic environment compared to traditional TPS, and thus present as an attractive alternative to TPS-coating for orthopedic spinal implants.

  9. Design limitations of Bryan disc arthroplasty.

    PubMed

    Fong, Shee Yan; DuPlessis, Stephan J; Casha, Steven; Hurlbert, R John

    2006-01-01

    Disc arthroplasty is gaining momentum as a surgical procedure in the treatment of spinal degenerative disease. Results must be carefully scrutinized to recognize benefits as well as limitations. The aim of this study was to investigate factors associated with segmental kyphosis after Bryan disc replacement. Prospective study of a consecutively enrolled cohort of 10 patients treated in a single center using the Bryan cervical disc prosthesis for single-level segmental reconstruction in the surgical treatment of cervical radiculopathy and/or myelopathy. Radiographic and quality of life outcome measures. Static and dynamic lateral radiographs were digitally analyzed in patients undergoing Bryan disc arthroplasty throughout a minimum 3-month follow-up period. Observations were compared with preoperative studies looking for predictive factors of postoperative spinal alignment. Postoperative end plate angles through the Bryan disc in the neutral position were kyphotic in 9 of 10 patients. Compared with preoperative end plate angulation there was a mean change of -7 degrees (towards kyphosis) in postoperative end plate alignment (p=.007, 95% confidence interval [CI] -6 degrees to -13 degrees). This correlated significantly with postoperative reduction in posterior vertebral body height of the caudal segment (p=.011, r2=.575) and postoperative functional spine unit (FSU) kyphosis (p=.032, r2=.46). Despite intraoperative distraction, postoperative FSU height was significantly reduced, on average by 1.7 mm (p=.040, 95% CI 0.5-2.8 mm). Asymmetrical end plate preparation occurs because of suboptimal coordinates to which the milling jig is referenced. Although segmental motion is preserved, Bryan disc arthroplasty demonstrates a propensity towards kyphotic orientation through the prosthesis likely as a result of intraoperative lordotic distraction. FSU angulation tends towards kyphosis and FSU height is decreased in the postoperative state from lack of anterior column support. Limitations of Bryan cervical disc arthroplasty should be carefully considered when reconstruction or maintenance of cervical lordosis is desirable.

  10. Comparative Study Between M6-C and Mobi-C Cervical Artificial Disc Replacement: Biomechanical Outcomes and Comparison with Normative Data.

    PubMed

    Pham, My; Phan, Kevin; Teng, Ian; Mobbs, Ralph J

    2018-05-01

    Cervical spondylosis affects a huge proportion of the middle-aged population. Degenerative changes can occur in multiple regions of the cervical spine typically affecting the joints, intervertebral discs and endplates. These changes lead to compression of adjacent nervous structures, which results in radiculopathic and myelopathic pain. Various treatment modalities are currently available with non-surgical approaches the initial go to if there is no symptomatic cord compression. Anterior cervical discectomy and fusion, or arthroplasty are the two common surgical approaches if non-surgical treatments fail to relieve symptoms of the patients or there are signs of central cord compression. However, studies have shown that there is an increased risk of adjacent segment disease related to fusion. Cervical disc arthroplasty aims to restore normal range of motion (ROM) in patients with pain and disability due to degenerative disc disease resistant to conservative care. Two common disc prostheses used include M6-C and Mobi-C. Both prostheses comprise a mobile polymer segment sandwiched between two metal endplates with mechanisms resembling an actual intervertebral disc. This study aims to compare the kinematics associated with these prostheses, against the normal range of motion in the non-degenerative population. Patients who underwent M6-C or Mobi-C disc replacements by the senior author from 2012 to 2015 were identified at a single tertiary institution. Routine 3-month postoperative lateral radiographs were analyzed for flexion and extension ROM angles at the involved vertebral level by two independent authors. Data was compared to previous published studies investigating cervical spine ROM of asymptomatic patients. There was no statistical significance in the difference of overall flexion range between M6-C and Mobi-C prostheses. However, overall range of extension of Mobi-C was greater compared to M6-C (P = 0.028). At C 5-6 , the range of flexion for both implants were similar but lesser compared to asymptomatic patients (P < 0.001). Range of extension was greater in the Mobi-C group (14.2° ± 5.1°) compared to the M6-C (7.3° ± 4.6°) (P = 0.0009). At C 6-7 , there were no statistical differences in both range of flexion and extension between the two prostheses and asymptomatic patients (P > 0.05). The early results regarding restoration of ROM following cervical arthroplasty using either M6-C or Mobi-C prosthesis are encouraging. Long-term follow-up studies are necessary to observe the change in ROM over time with physiological loading and wear patterns. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  11. Possible applications of time domain reflectometry in planetary exploration missions

    NASA Technical Reports Server (NTRS)

    Heckendorn, S.

    1982-01-01

    The use of a time domain reflectometer (TDR) for planetary exploration is considered. Determination of the apparent dielectric constant and hence, the volumetric water content of frozen and unfrozen soils using the TDR is described. Earth-based tests were performed on a New York state sandy soil and a Wyoming Bentonite. Use of both a cylindrical coaxial transmission line and a parallel transmission line as probes was evaluated. The water content of the soils was varied and the apparent dielectric constant measured in both frozen and unfrozen states. Advantages and disadvantages of the technique are discussed.

  12. A case of industrial safety appraisal for extension of service life of GTK-10-4 gas turbines used at gas transmission stations

    NASA Astrophysics Data System (ADS)

    Rybnikov, A. I.; Kovalev, A. G.; Kryukov, I. I.; Leont'ev, S. A.; Moshnikov, A. V.

    2017-04-01

    It is shown that the extended life and enhanced operational reliability of parts and subassemblies of the most popular GTK-10-4 gas transmission plants are determined by the enhanced efficiency of the control over technical condition and operational safety of turbine plants in conformity with industrial safety requirements imposed on gas pipeline compressor stations. It has been established that the materials of parts and subassemblies of gas turbine plants with different, especially with maximal operating time, shall be exposed to NDT for the purpose of determining the actual mechanical characteristics of these materials with different operating time and calculating residual life. The analysis of damageability and operating conditions has helped to identify parts and subassemblies for repair or replacement with the highest frequency of unacceptable defects. These parts and subassemblies have been shown to include base members of the axial compressor (AC), a turbine housing, an axial compressor rotor, high- and low-pressure turbine (HPT and LPT) discs, a 12-part holder, the housing of the holder of HPT and LPT guiding blades, a sealed baffler, and working and guiding AC, LPT and HPT blades. The most typical operational defects have been enumerated and analyzed. It has been determined that the primary task of the industrial safety appraisal for extending the life of GTK-10-4 with limit-exceeding operating time is to thoroughly examine HPT and LPT discs with more than 130,000 hours of operating time and establish by DT methods characteristics of materials for evaluation, taking account of their degradation, and residual life of critical turbine elements. In addition, it has been shown that the service life of HP turbine discs can be extended by replacing the disc material (EP-428 12% chromium steel) with a material with a higher linear expansion factor that somewhat exceeds the expansion factor of EI-893 nickel alloy used to melt out working blades.

  13. Biomechanics of Artificial Disc Replacements Adjacent to a 2-Level Fusion in 4-Level Hybrid Constructs: An In Vitro Investigation

    PubMed Central

    Liao, Zhenhua; Fogel, Guy R.; Wei, Na; Gu, Hongsheng; Liu, Weiqiang

    2015-01-01

    Background The ideal procedure for multilevel cervical degenerative disc diseases remains controversial. Recent studies on hybrid surgery combining anterior cervical discectomy and fusion (ACDF) and artificial cervical disc replacement (ACDR) for 2-level and 3-level constructs have been reported in the literature. The purpose of this study was to estimate the biomechanics of 3 kinds of 4-level hybrid constructs, which are more likely to be used clinically compared to 4-level arthrodesis. Material/Methods Eighteen human cadaveric spines (C2–T1) were evaluated in different testing conditions: intact, with 3 kinds of 4-level hybrid constructs (hybrid C3–4 ACDR+C4–6 ACDF+C6–7ACDR; hybrid C3–5ACDF+C5–6ACDR+C6–7ACDR; hybrid C3–4ACDR+C4–5ACDR+C5–7ACDF); and 4-level fusion. Results Four-level fusion resulted in significant decrease in the C3–C7 ROM compared with the intact spine. The 3 different 4-level hybrid treatment groups caused only slight change at the instrumented levels compared to intact except for flexion. At the adjacent levels, 4-level fusion resulted in significant increase of contribution of both upper and lower adjacent levels. However, for the 3 hybrid constructs, significant changes of motion increase far lower than 4P at adjacent levels were only noted in partial loading conditions. No destabilizing effect or hypermobility were observed in any 4-level hybrid construct. Conclusions Four-level fusion significantly eliminated motion within the construct and increased motion at the adjacent segments. For all 3 different 4-level hybrid constructs, ACDR normalized motion of the index segment and adjacent segments with no significant hypermobility. Compared with the 4-level ACDF condition, the artificial discs in 4-level hybrid constructs had biomechanical advantages compared to fusion in normalizing adjacent level motion. PMID:26694835

  14. Biomechanics of Artificial Disc Replacements Adjacent to a 2-Level Fusion in 4-Level Hybrid Constructs: An In Vitro Investigation.

    PubMed

    Liao, Zhenhua; Fogel, Guy R; Wei, Na; Gu, Hongsheng; Liu, Weiqiang

    2015-12-23

    BACKGROUND The ideal procedure for multilevel cervical degenerative disc diseases remains controversial. Recent studies on hybrid surgery combining anterior cervical discectomy and fusion (ACDF) and artificial cervical disc replacement (ACDR) for 2-level and 3-level constructs have been reported in the literature. The purpose of this study was to estimate the biomechanics of 3 kinds of 4-level hybrid constructs, which are more likely to be used clinically compared to 4-level arthrodesis. MATERIAL AND METHODS Eighteen human cadaveric spines (C2-T1) were evaluated in different testing conditions: intact, with 3 kinds of 4-level hybrid constructs (hybrid C3-4 ACDR+C4-6 ACDF+C6-7ACDR; hybrid C3-5ACDF+C5-6ACDR+C6-7ACDR; hybrid C3-4ACDR+C4-5ACDR+C5-7ACDF); and 4-level fusion. RESULTS Four-level fusion resulted in significant decrease in the C3-C7 ROM compared with the intact spine. The 3 different 4-level hybrid treatment groups caused only slight change at the instrumented levels compared to intact except for flexion. At the adjacent levels, 4-level fusion resulted in significant increase of contribution of both upper and lower adjacent levels. However, for the 3 hybrid constructs, significant changes of motion increase far lower than 4P at adjacent levels were only noted in partial loading conditions. No destabilizing effect or hypermobility were observed in any 4-level hybrid construct. CONCLUSIONS Four-level fusion significantly eliminated motion within the construct and increased motion at the adjacent segments. For all 3 different 4-level hybrid constructs, ACDR normalized motion of the index segment and adjacent segments with no significant hypermobility. Compared with the 4-level ACDF condition, the artificial discs in 4-level hybrid constructs had biomechanical advantages compared to fusion in normalizing adjacent level motion.

  15. Effects of Neonatal Enzyme Replacement Therapy and Simvastatin Treatment on Cervical Spine Disease in Mucopolysaccharidosis I Dogs

    PubMed Central

    Chiaro, Joseph A; O’Donnell, Patricia; Shore, Eileen M; Malhotra, Neil R; Ponder, Katherine P; Haskins, Mark E; Smith, Lachlan J

    2014-01-01

    Mucopolysaccharidosis I (MPS I) is a lysosomal storage disease characterized by deficient α-L-iduronidase activity, leading to the accumulation of poorly degraded glycosaminoglycans (GAGs). Children with MPS I exhibit high incidence of spine disease, including accelerated disc degeneration and vertebral dysplasia, which in turn lead to spinal cord compression and kypho-scoliosis. In this study we investigated the efficacy of neonatal enzyme replacement therapy (ERT), alone or in combination with oral simvastatin (ERT+SIM) for attenuating cervical spine disease progression in MPS I, using a canine model. Four groups were studied: normal controls; MPS I untreated; MPS I ERT treated; and MPS I ERT+SIM treated. Animals were euthanized at one year-of-age. Intervertebral disc condition and spinal cord compression were evaluated from MRIs and plain radiographs, vertebral bone condition and odontoid hypoplasia were evaluated using microcomputed tomography, and epiphyseal cartilage to bone conversion was evaluated histologically. Untreated MPS I animals exhibited more advanced disc degeneration and more severe spinal cord compression than normal animals. Both treatment groups resulted in partial preservation of disc condition and cord compression, with ERT+SIM not significantly better than ERT alone. Untreated MPS I animals had significantly lower vertebral trabecular bone volume and mineral density, while ERT treatment resulted in partial preservation of these properties. ERT+SIM treatment demonstrated similar, but not greater, efficacy. Both treatment groups partially normalized endochondral ossification in the vertebral epiphyses (as indicated by absence of persistent growth plate cartilage), and odontoid process size and morphology. These results indicate that ERT begun from a very early age attenuates the severity of cervical spine disease in MPS I, particularly for the vertebral bone and odontoid process, and that additional treatment with simvastatin does not provide a significant additional benefit over ERT alone. PMID:24898323

  16. Neurological complications of lumbar artificial disc replacement and comparison of clinical results with those related to lumbar arthrodesis in the literature: results of a multicenter, prospective, randomized investigational device exemption study of Charité intervertebral disc. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004.

    PubMed

    Geisler, Fred H; Blumenthal, Scott L; Guyer, Richard D; McAfee, Paul C; Regan, John J; Johnson, J Patrick; Mullin, Bradford

    2004-09-01

    Arthrodesis is the gold standard for surgical treatment of lumbar degenerative disc disease (DDD). Solid fusion, however, can cause stress and increased motion in the segments adjacent to the fused level. This may initiate and/or accelerate the adjacent-segment disease process. Artificial discs are designed to restore and maintain normal motion of the lumbar intervertebral segment. Restoring and maintaining normal motion of the segment reduces stresses and loads on adjacent level segments. A US Food and Drug Administration Investigational Device Exemptions multicentered study of the Charité artificial disc was completed. The control group consisted of individuals who underwent anterior lumbar interbody fusion involving BAK cages and iliac crest bone graft. This is the first report of Class I data in which a lumbar artificial disc is compared with lumbar fusion. Of 304 individuals enrolled in the study, 205 were randomized to the Charité disc-treated group and 99 to the BAK fusion-treated (control) group. Neurological status was equivalent between the two groups at 6, 12, and 24 months postoperatively. The number of patients with major, minor, or other neurological complications was equivalent. There was a greater incidence of both major and minor complications in the BAK fusion group at 0 to 42 days postoperatively. Compared with data reported in the lumbar fusion literature, the Charité disc-treated patients had equivalent or better mean changes in visual analog scale and Oswestry Disability Index scores. The Charité artificial disc is safe and effective for the treatment of single-level lumbar DDD, resulting in no higher incidence of neurological complications compared with BAK-assisted fusion and leading to equivalent or better outcomes compared with those obtained in the control group and those reported in the lumbar fusion literature.

  17. Rationale, principles and experimental evaluation of the concept of soft stabilization.

    PubMed

    Mulholland, Robert C; Sengupta, Dilip K

    2002-10-01

    The apparent clinical success of spinal stabilization methods that restrict rather than abolish movement in relieving mechanical back pain indicates that the concept of the aetiology of back pain should be reviewed. Further understanding of how degeneration affects disc biomechanics, and an understanding of how current soft stabilization systems alters them, may allow us to define more precisely what are the essential requirements of an ideal soft stabilization system. It appears that abnormal patterns of loading rather than abnormal movement are the reason that disc degeneration causes back pain in some patients. Abnormal load transmission is the principal cause of pain in osteoarthritic joints, and both osteotomy and, indeed, joint replacement succeed because they alter the load transmission across the joint. This concept is supported by the fact that abnormal patterns of stress distribution measured across the disc correlate with painful discs on discography. Clinically, it is often noted that back pain is primarily related to position or posture, rather than movement of the lumbar spine. Clinical success after solid fusion is unpredictable because it does not necessarily prevent painful loading across the disc, and also it may interfere with maintenance of sagittal balance in varying postures. The Graf ligament restricted flexion, and was modestly successful. It unfortunately increased the load over the posterior annulus. The Dynesys system reduces movement both in flexion and extension, and appears to be more successful. However, often it also unloads the disc to a degree that is unpredictable. The authors believe that this unloading of the disc is an important feature of a flexible stabilization system. A new a design of a flexible stabilization system has recently been described in an in vitro study, which unloads the disc by introduction of a load-sharing fulcrum near the axis of movement together with an elastic posterior ligament. This design produces maximal unloading of the disc, whilst allowing a restricted range of movement, which serves the important purpose of allowing the patient to maintain sagittal balance in varying postures.

  18. Assessment of initial soil moisture conditions for event-based rainfall-runoff modelling

    NASA Astrophysics Data System (ADS)

    Tramblay, Yves; Bouvier, Christophe; Martin, Claude; Didon-Lescot, Jean-François; Todorovik, Dragana; Domergue, Jean-Marc

    2010-06-01

    Flash floods are the most destructive natural hazards that occur in the Mediterranean region. Rainfall-runoff models can be very useful for flash flood forecasting and prediction. Event-based models are very popular for operational purposes, but there is a need to reduce the uncertainties related to the initial moisture conditions estimation prior to a flood event. This paper aims to compare several soil moisture indicators: local Time Domain Reflectometry (TDR) measurements of soil moisture, modelled soil moisture through the Interaction-Sol-Biosphère-Atmosphère (ISBA) component of the SIM model (Météo-France), antecedent precipitation and base flow. A modelling approach based on the Soil Conservation Service-Curve Number method (SCS-CN) is used to simulate the flood events in a small headwater catchment in the Cevennes region (France). The model involves two parameters: one for the runoff production, S, and one for the routing component, K. The S parameter can be interpreted as the maximal water retention capacity, and acts as the initial condition of the model, depending on the antecedent moisture conditions. The model was calibrated from a 20-flood sample, and led to a median Nash value of 0.9. The local TDR measurements in the deepest layers of soil (80-140 cm) were found to be the best predictors for the S parameter. TDR measurements averaged over the whole soil profile, outputs of the SIM model, and the logarithm of base flow also proved to be good predictors, whereas antecedent precipitations were found to be less efficient. The good correlations observed between the TDR predictors and the S calibrated values indicate that monitoring soil moisture could help setting the initial conditions for simplified event-based models in small basins.

  19. Transmitted drug resistance is still low in newly diagnosed human immunodeficiency virus type 1 CRF06_cpx-infected patients in Estonia in 2010.

    PubMed

    Avi, Radko; Huik, Kristi; Pauskar, Merit; Ustina, Valentina; Karki, Tõnis; Kallas, Eveli; Jõgeda, Ene-Ly; Krispin, Tõnu; Lutsar, Irja

    2014-03-01

    The presence of transmitted drug resistance (TDR) in treatment-naive HIV-1-positive subjects is of concern, especially in the countries of the former Soviet Union in which the number of subjects exposed to antiretrovirals (ARV) has exponentially increased during the past decade. We assessed the rate of TDR among newly diagnosed subjects in Estonia in 2010 and compared it to that in 2008. The study included 325 subjects (87% of all subjects tested HIV positive from January 1 to December 31, 2010). Of the 244 sequenced viral genomic RNA in the reverse transcriptase (RT) region 214 were CRF06_cpx, nine were subtype A1, three (one each) were subtype B and subtype C, CRF02_AG, and CRF03_AB; 15 viruses remained unclassified as putative recombinant forms between CRF06_cpx and subtype A1. HIV-1 TDR mutations in 2010 and 2008 (n=145) occurred at similar frequency in 4.5% (95% CI 2.45; 7.98) and 5.5% (95% CI 1.8; 9.24) of the patients, respectively. In 2010, 2.5% (6/244) of the sequences harbored nonnucleoside reverse transcriptase inhibitor (NNRTI) (K103N and K101E), 1.6% (4/244) nucleoside reverse transcriptase inhibitor (NRTI) (M41L, M184I, and K219E), and 0.4% (1/244) protease inhibitor (PI) (V82A) mutations. Our findings indicate that in spite of the increased consumption of ARVs the rate of TDR in Estonia has remained unchanged over the past 3 years. Similar stabilizing or even decreasing trends have been described in Western Europe and North America albeit at higher levels and in different socioeconomic backgrounds.

  20. Time-divided ingestion pattern of casein-based protein supplement stimulates an increase in fat-free body mass during resistance training in young untrained men.

    PubMed

    Burk, Andres; Timpmann, Saima; Medijainen, Luule; Vähi, Mare; Oöpik, Vahur

    2009-06-01

    We hypothesized that during prolonged resistance training, time-divided ingestion pattern of casein-based protein supplement is of superior efficiency in comparison with the ingestion of the same supplement immediately before each training session. In a crossover study, 13 men aged 18 to 19 years were evaluated during 2 well-controlled, 8-week training and supplementation periods. In the time-focused supplementation regimen (TFR), the subjects consumed the supplement in the morning and in the afternoon, immediately before the training session. Time-divided supplementation regimen (TDR) included 1 morning dose, whereas the second dose was ingested in the evening, 5 hours after training. The daily dose of the supplement contained approximately 70 g of protein (82% casein) and less than 1 g of carbohydrate and fat. Body mass, body composition (dual-energy x-ray absorptiometry scanned), and one-repetition maximum (1RM) for bench press and squat were determined at the beginning and at the end of both 8-week training and supplementation periods. Training produced a significant increase in 1RM strength both in the bench press (9.4% and 7.2%) and the squat exercise (10.7% and 17.8%) in the TFR and TDR, respectively, with no differences between the supplementation regimens. Fat-free mass increased from 62.4 +/- 1.2 to 63.5 +/- 1.3 kg (P = .046) with TDR, whereas no change was evident with TFR. The increase in 1RM strength in the squat exercise was related to the increase in fat-free mass in TDR (r = 0.569; P = .041). These findings may have practical implications for the timing of ingestion of protein supplements to enhance the efficacy of resistance training.

  1. Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients

    PubMed Central

    Ma, Wei-Guo; Hou, Bin; Abdurusul, Adiljan; Gong, Ding-Xu; Tang, Yue; Chang, Qian; Xu, Jian-Ping

    2015-01-01

    Background Dysfunction of mechanical heart valve prostheses is an unusual but potentially lethal complication after mechanical prosthetic valve replacement. We seek to report our experience with mechanical valve dysfunction regarding etiology, surgical techniques and early outcomes. Methods Clinical data of 48 patients with mechanical valve dysfunction surgically treated between October 1996 and June 2011 were analyzed. Results Mean age was 43.7±10.9 years and 34 were female (70.8%). The median interval from primary valve implantation to dysfunction was 44.5 months (range, 1 hour to 20 years). There were 21 emergent and 27 elective reoperations. The etiology was thrombosis in 19 cases (39.6%), pannus in 12 (25%), thrombosis and pannus in 11 (22.9%), improper disc orientation in 2 (4.1%), missing leaflet in 1 (2.1%), excessively long knot end in 1 (2.1%), endogenous factor in 1 (2.1%) and unidentified in 1 (2.1%). Surgical procedure was mechanical valve replacement in 37 cases (77.1%), bioprosthetic valve replacement in 7 (14.9%), disc rotation in 2 (4.2%) and excision of excessive knot end in 1 (2.1%). Early deaths occurred in 7 patients (14.6%), due to low cardiac output in 3 (6.3%), multi-organ failure in 2 (4.2%) and refractory ventricular fibrillation in 2 (4.2%). Complications occurred in 10 patients (20.8%). Conclusions Surgical management of mechanical valve dysfunction is associated with significant mortality and morbidity. Earlier identification and prompt reoperation are vital to achieving better clinical outcomes. The high incidence of thrombosis in this series highlights the need for adequate anticoagulation and regular follow-up after mechanical valve replacement. PMID:26793354

  2. Early UV emission from disc-originated matter (DOM) in Type Ia supernovae in the double-degenerate scenario

    NASA Astrophysics Data System (ADS)

    Levanon, Naveh; Soker, Noam

    2017-09-01

    We show that the blue and UV excess emission in the first few days of some Type Ia supernovae (SNe Ia) can be accounted in the double-degenerate (DD) scenario by the collision of the SN ejecta with circumstellar matter that was blown by the accretion disc formed during the merger process of the two white dwarfs (WDs). We assume that in cases of excess early light, the disc blows the circumstellar matter, that we term disc-originated matter (DOM), hours to days before explosion. To perform our analysis, we first provide a model-based definition for early excess light, replacing the definition of excess light relative to a power-law fit to the rising luminosity. We then examine the light curves of the SNe Ia iPTF14atg and SN 2012cg, and find that the collision of the ejecta with a DOM in the frame of the DD scenario can account for their early excess emission. Thus, early excess light does not necessarily imply the presence of a stellar companion in the frame of the single-degenerate scenario. Our findings further increase the variety of phenomena that the DD scenario can account for, and emphasize the need to consider all different SN Ia scenarios when interpreting observations.

  3. Adaptive alterations of elastic fibers in the bilaminar zone of rabbit temporomandibular joint following disc displacement.

    PubMed

    Gu, Zhiyuan; Wu, Huiling; Feng, Jianying; Shibata, Takanori; Hu, Ji'an; Zhang, Yinkai; Xie, Zhijian

    2002-12-01

    To study the adaptive alterations of elastic fibers in the bilaminar zone (BZ) of rabbit temporomandibular joint (TMJ) following disc displacement. Twenty-eight Japanese white rabbits were used in this study. The right temporomandibular joints of 20 of 28 rabbits were subjected to the surgical procedure of anterior disc displacement (ADD). Four rabbits in the surgical group were sacrificed at 2, 4, 6, 8 and 12 weeks after operation. Their temporomandibular joints were studied histochemically. Elastic fibers were reduced in number and ran irregularly in the superior lamina of BZ from ADD rabbits. The jungly elastic fibers (EFs) could still be seen at 2 weeks after operation. At 4 weeks, the number of EFs decreased significantly; EFs lost their jungly arrangement and were shaped like rough dots, of which the arrangement and the lengths were different. Six weeks after operation, many EFs were replaced by distorted, uneven, non-oriented fine EFs, distributed unevenly and some thick or fine EFs that ran irregularly. The number of EFs decreased further and their arrangement was more deranged at 8 weeks. At 10 and 12 weeks, EFs in the superior lamina of BZ were similar to those at 8 weeks. Our results show that EFs lost their function as well as their distribution and arrangement after disc displacement.

  4. Structural Investigations of Afghanistan Deduced from Remote Sensing and Potential Field Data

    NASA Astrophysics Data System (ADS)

    Saibi, Hakim; Azizi, Masood; Mogren, Saad

    2016-08-01

    This study integrates potential gravity and magnetic field data with remotely sensed images and geological data in an effort to understand the subsurface major geological structures in Afghanistan. Integrated analysis of Landsat SRTM data was applied for extraction of geological lineaments. The potential field data were analyzed using gradient interpretation techniques, such as analytic signal (AS), tilt derivative (TDR), horizontal gradient of the tilt derivative (HG-TDR), Euler Deconvolution (ED) and power spectrum methods, and results were correlated with known geological structures. The analysis of remote sensing data and potential field data reveals the regional geological structural characteristics of Afghanistan. The power spectrum analysis of magnetic and gravity data suggests shallow basement rocks at around 1 to 1.5 km depth. The results of TDR of potential field data are in agreement with the location of the major regional fault structures and also the location of the basins and swells, except in the Helmand region (SW Afghanistan) where many high potential field anomalies are observed and attributed to batholiths and near-surface volcanic rocks intrusions. A high-resolution airborne geophysical survey in the data sparse region of eastern Afghanistan is recommended in order to have a complete image of the potential field anomalies.

  5. An effective hair detection algorithm for dermoscopic melanoma images of skin lesions

    NASA Astrophysics Data System (ADS)

    Chakraborti, Damayanti; Kaur, Ravneet; Umbaugh, Scott; LeAnder, Robert

    2016-09-01

    Dermoscopic images are obtained using the method of skin surface microscopy. Pigmented skin lesions are evaluated in terms of texture features such as color and structure. Artifacts, such as hairs, bubbles, black frames, ruler-marks, etc., create obstacles that prevent accurate detection of skin lesions by both clinicians and computer-aided diagnosis. In this article, we propose a new algorithm for the automated detection of hairs, using an adaptive, Canny edge-detection method, followed by morphological filtering and an arithmetic addition operation. The algorithm was applied to 50 dermoscopic melanoma images. In order to ascertain this method's relative detection accuracy, it was compared to the Razmjooy hair-detection method [1], using segmentation error (SE), true detection rate (TDR) and false positioning rate (FPR). The new method produced 6.57% SE, 96.28% TDR and 3.47% FPR, compared to 15.751% SE, 86.29% TDR and 11.74% FPR produced by the Razmjooy method [1]. Because of the 7.27-9.99% improvement in those parameters, we conclude that the new algorithm produces much better results for detecting thick, thin, dark and light hairs. The new method proposed here, shows an appreciable difference in the rate of detecting bubbles, as well.

  6. Total Defense + Repair: A Novel Concept in Solar Protection and Skin Rejuvenation.

    PubMed

    McDaniel, David H; Hamzavi, Iltefat H; Zeichner, Joshua A; Fabi, Sabrina G; Bucay, Vivian W; Harper, Julie C; Comstock, Jody A; Makino, Elizabeth T; Mehta, Rahul C; Vega, Virginia L

    2015-07-01

    For more than a century, solar radiation has been known to contribute significantly to the extrinsic aging of skin. Until recently, this was almost exclusively attributed to the photodamage caused by ultraviolet (UV) light. However, a growing body of evidence now indicates that both infrared (IR) and visible light may also contribute to extrinsic skin aging. Infrared radiation, comprised of IR-A, IR-B, and IR-C, accounts for 54.3% of the total solar radiation reaching the skin. Studies have shown that IR radiation is also responsible for skin aging. Thus, IR-A radiation regulates hundreds of genes in skin, with roles in extracellular matrix (ECM) homeostasis regulation, apoptosis, cell growth, and stress responses. IR-B and IR-C radiation are primarily responsible for the increase in skin temperature associated with solar exposure, and are implicated in heat-related skin destruction of collagen and elastin, which is characterized by an increase in the expression of matrix metalloproteinases (MMPs). The contribution of visible light to photoaging is less well understood; however, some preliminary indication associates visible light with the upregulation of MMPs' expression, DNA damage, and keratinocyte proliferation. Interestingly, the common denominator that links skin damage to the different solar wavelengths is the enhanced production of reactive molecule species (RMS) and therewith increased oxidative stress. SkinMedica® Total Defense + Repair (TD+R; SkinMedica Inc., an Allergan company, Irvine, CA) is a "superscreen," which combines broad spectrum UV protection with a unique blend of antioxidants (SOL-IR Advanced Antioxidant Complex™) that provide protection from IR radiation while promoting skin repair. Preclinical studies have indicated that TD+R SPF34 prevents the formation of UV-induced sunburn cells and cyclobutane pyrimidine dimers while preserving or improving the expression of ECM genes. In addition, it prevents IR-A-triggered fragmentation of elastin fibers and expression of MMP-1. Initial clinical studies indicate that TDR+R SPF34 reduces the increase in surface temperature seen with IR radiation. A significant improvement in the appearance of lines and wrinkles was reported as early as week 2 in patients using TDR+R SPF34. In summary, we observed that the unique blend of antioxidants present in TD+R acts in harmony with SPF active ingredients, expanding solar protection beyond UV radiation and counterbalancing the deleterious effects of free radicals on skin cells by promoting endogenous repair.

  7. Tracking the career development of scientists in low- and middle-income countries trained through TDR’s research capacity strengthening programmes: Learning from monitoring and impact evaluation

    PubMed Central

    Halpaap, Béatrice; Vahedi, Mahnaz; Certain, Edith; Alvarado, Tini; Saint Martin, Caroline; Merle, Corinne; Mihut, Michael

    2017-01-01

    The Special Programme for Research and Training in Tropical Diseases (TDR) co-sponsored by UNICEF, UNDP, World Bank and WHO has been supporting research capacity strengthening in low- and middle-income countries for over 40 years. In order to assess and continuously optimize its capacity strengthening approaches, an evaluation of the influence of TDR training grants on research career development was undertaken. The assessment was part of a larger evaluation conducted by the European Science Foundation. A comprehensive survey questionnaire was developed and sent to a group of 117 trainees supported by TDR who had completed their degree (masters or PhD) between 2000 and 2012; of these, seventy seven (77) responded. Most of the respondents (80%) rated TDR support as a very important factor that influenced their professional career achievements. The “brain drain” phenomenon towards high-income countries was particularly low amongst TDR grantees: the rate of return to their region of origin upon completion of their degree was 96%. A vast majority of respondents are still working in research (89%), with 81% of respondents having participated in multidisciplinary research activities; women engaged in multidisciplinary collaboration to a higher extent than men. However, only a minority of all have engaged in intersectoral collaboration, an aspect that would require further study. The post-degree career choices made by the respondents were strongly influenced by academic considerations. At the time of the survey, 92% of all respondents hold full-time positions, mainly in the public sector. Almost 25% of the respondents reported that they had influenced policy and practice changes. Some of the challenges and opportunities faced by trainees at various stages of their research career have been identified. Modalities to overcome these will require further investigation. The survey evidenced how TDR’s research capacity grant programmes made a difference on researchers’ career development and on south-south collaborations, by strengthening and localizing research capacity in lower income regions, and also showed there is more that needs to be done. The factors involved, challenges and lessons learnt may help donors and policy makers improve their future interventions with regard to designing capacity strengthening programmes and setting funding priorities. PMID:29216192

  8. [Surgical treatment of thoracic disc herniation].

    PubMed

    Hrabálek, L; Kalita, O; Langová, K

    2010-08-01

    The aim of this study was to compare the efficiency of different surgical approaches to thoracic disc herniation, and to show the role of segmental fusion and selection of an appropriate microsurgical decompression technique for the successful outcome of surgery. A group of 27 patients, 10 men and 17 women, between 31 and 70 years (average age, 49.33 years) were included in this prospective study. They underwent surgery for thoracic degeneration disc disease in the period from June 1994 to August 2008. In all patients, the severity of myelopathy was assessed using the grading Frankel system and JOA score, axial and radicular pain intensity was evaluated with VAS and ODI rating systems. The diagnosis was established on the basis of thoracic spine radiography, thoracic spine MRI and a CT scan of the segment. A total of 30 thoracic segments, in the range of Th4/Th5 to Th12/L1, were indicated for surgery. Localisation of the hernia was medial at 19 segments, mediolateral at three and lateral at eight segments. Soft disc herniation was found in 17 cases and hard disc protrusion at the remaining 13 segments. Surgery for significant myelopathy was carried out in 23 patients and for pain in four patients. According to the surgical procedure used, the patients were allocated to two groups: group A comprised 10 patients treated without disc replacement through a laminectomy or a costotransversectomy exposure, and group B consisted of 17 patients undergo- ing intersomatic fusion via a thoracotomy. Clinical and radiographic examinations were made at regular intervals for at least 1 year of follow-up. The results of clinical assessment, including JOA scores, JOA Recovery Rate, VAS scores at rest and after exercise and ODI, were statistically analysed for each group and compared. There was a statistically significant difference in JOA evaluation of myelopathy between the groups in group A, the mean JOA score declined from 7.9 to 7.0, i.e., -0.9 point, while in group B it increased from 6.71 to 9.12, i.e., +2.41 points. The mean JOA Recovery Rate did not reach a plus value in group A, while in group B it improved by 55 %. JOA Recovery Rate: Of the seven patients in group A evaluated for myelopathy, a fair result was in one, unchanged in two and worse in four patients. Of the 16 patients evaluated for myelopathy in group B, the results were excellent in four, good in six, fair in four and unchanged in two patients. Frankel grade function: In group A, one patient improved by one grade, two remained unchanged, two deteriorated by one grade and two by two grades. In group B, five patients improved by one grade, two patients by two grades and two patients by three grades. Eight patients remained unchanged and no patient deteriorated. The post-operative pain intensity, as assessed by the mean VAS score, was lower at rest and after exercise in both groups; the score was better in group B, but the difference was not statistically significant. The ODI was evaluated only in group B its mean value improved from 41.4% to 26.1%, i.e., by 15.3%. Between 7 to 15 % of the patients have asymptomatic thoracic disc herniation, while symptomatic herniation is very rare and accounts for only 0.25 % to 0.57 % of herniated discs in the whole spine. Severe or progressive myelopathy is a clear indication for surgical intervention in thoracic disc herniation, but the role of surgery in pain control is controversial. There are five approaches for thoracic disc herniation. Transpleural anterolateral thoracotomy has an advantage over the other methods because it permits the treatment of all types of herniation, whether localised centrally, laterally or contralaterally, i.e., soft, calcified or sequestered intradural disc herniation. The results of treatment will depend on the outcome of surgical spinal cord decompression and the degree of spinal stabilisation achieved. The surgical procedure via thoracotomy with intersomatic fusion resulted in a statistically more significant improvement of myelopathy than the posterior approach without disc replacement, and it provided greater pain relief. The authors recommend to treat thoracic disc herniation by discectomy via a thoracotomy and by intersomatic fusion.

  9. Fortifying the Bone-Implant Interface Part 1: An In Vitro Evaluation of 3D-Printed and TPS Porous Surfaces

    PubMed Central

    Lindsey, Derek P.; Bahney, Chelsea S.; Woods, Shane A.; Wolfe, Mark L.; Yerby, Scott A.

    2017-01-01

    Background An aging society and concomitant rise in the incidence of impaired bone health have led to the need for advanced osteoconductive spinal implant surfaces that promote greater biological fixation (e.g. for interbody fusion cages, sacroiliac joint fusion implants, and artificial disc replacements). Additive manufacturing, i.e. 3D-printing, may improve bone integration by generating biomimetic spinal implant surfaces that mimic bone morphology. Such surfaces may foster an enhanced cellular response compared to traditional implant surfacing processes. Methods This study investigated the response of human osteoblasts to additive manufactured (AM) trabecular-like titanium implant surfaces compared to traditionally machined base material with titanium plasma spray (TPS) coated surfaces, with and without a nanocrystalline hydroxyapatite (HA) coating. For TPS-coated discs, wrought Ti6Al4V ELI was machined and TPS-coating was applied. For AM discs, Ti6Al4V ELI powder was 3D-printed to form a solid base and trabecular-like porous surface. The HA-coating was applied via a precipitation dip-spin method. Surface porosity, pore size, thickness, and hydrophilicity were characterized. Initial cell attachment, proliferation, alkaline phosphatase (ALP) activity, and calcium production of hFOB cells (n=5 per group) were measured. Results Cells on AM discs exhibited expedited proliferative activity. While there were no differences in mean ALP expression and calcium production between TPS and AM discs, calcium production on the AM discs trended 48% higher than on TPS discs (p=0.07). Overall, HA-coating did not further enhance results compared to uncoated TPS and AM discs. Conclusions Results demonstrate that additive manufacturing allows for controlled trabecular-like surfaces that promote earlier cell proliferation and trends toward higher calcium production than TPS coating. Results further showed that nanocrystalline HA may not provide an advantage on porous titanium surfaces. Clinical Relevance Additive manufactured porous titanium surfaces may induce a more osteogenic environment compared to traditional TPS, and thus present as an attractive alternative to TPS-coating for orthopedic spinal implants. PMID:28765799

  10. Evolution of Information Management at the GSFC Earth Sciences (GES) Data and Information Services Center (DISC): 2006-2007

    NASA Technical Reports Server (NTRS)

    Kempler, Steven; Lynnes, Christopher; Vollmer, Bruce; Alcott, Gary; Berrick, Stephen

    2009-01-01

    Increasingly sophisticated National Aeronautics and Space Administration (NASA) Earth science missions have driven their associated data and data management systems from providing simple point-to-point archiving and retrieval to performing user-responsive distributed multisensor information extraction. To fully maximize the use of remote-sensor-generated Earth science data, NASA recognized the need for data systems that provide data access and manipulation capabilities responsive to research brought forth by advancing scientific analysis and the need to maximize the use and usability of the data. The decision by NASA to purposely evolve the Earth Observing System Data and Information System (EOSDIS) at the Goddard Space Flight Center (GSFC) Earth Sciences (GES) Data and Information Services Center (DISC) and other information management facilities was timely and appropriate. The GES DISC evolution was focused on replacing the EOSDIS Core System (ECS) by reusing the In-house developed disk-based Simple, Scalable, Script-based Science Product Archive (S4PA) data management system and migrating data to the disk archives. Transition was completed in December 2007

  11. Pannus-related prosthetic valve dysfunction. Case report

    PubMed Central

    MOLDOVAN, MARIA-SÎNZIANA; BEDELEANU, DANIELA; KOVACS, EMESE; CIUMĂRNEAN, LORENA; MOLNAR, ADRIAN

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction. PMID:27004041

  12. Pannus-related prosthetic valve dysfunction. Case report.

    PubMed

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  13. [Design and research progress of zero profile cervical Interbody cage].

    PubMed

    Zhu, Jia; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2017-02-01

    Zero profile cervical interbody cage is an improvement of traditional fusion products and necessary supplement of emerging artificial intervertebral disc products. When applied in Anterior Cervical Decompression Fusion(ACDF), zero profile cervical interbody cage can preserve the advantages of traditional fusion and reduce the incidence of postoperative complications. Moreover, zero profile cervical interbody cage can be applied under the tabu symptoms of Artificial Cervical Disc Replacement(ACDR). This article summarizes zero profile interbody cage products that are commonly recognized and widely used in clinical practice in recent years, and reviews the progress of structure design and material research of zero profile cervical interbody cage products. Based on the latest clinical demands and research progress, this paper also discusses the future development directions of zero profile interbody cage.

  14. Biomechanical Characterization of an Annulus Sparing Spinal Disc Prosthesis

    PubMed Central

    Buttermann, Glenn R.; Beaubien, Brian P.

    2009-01-01

    Background Context Current spine arthroplasty devices, require disruption of the annulus fibrosus for implantation. Preliminary studies of a unique annulus sparing intervertebral prosthetic disc (IPD), found that preservation of the annulus resulted in load sharing of the annulus with the prosthesis. Purpose Determine flexibility of the IPD versus fusion constructs in normal and degenerated human spines. Study design/Setting Biomechanical comparison of motion segments in the intact, fusion and mechanical nucleus replacement states for normal and degenerated states. Patient setting Thirty lumbar motion segments. Outcomes Measures Intervertebral height; motion segment range-of-motion (ROM), neutral zone (NZ), stiffness. Methods Motion segments had multi-directional flexibility testing to 7.5 Nm for intact discs, discs reconstructed using the IPD (n=12), or after anterior/posterior fusions (n=18). Interbody height and axial compression stiffness changes were determined for the reconstructed discs by applying axial compression to 1500 N. Analysis included stratifying results to normal mobile vs. rigid degenerated intact motion segments. Results The mean interbody height increase was 1.5 mm for IPD reconstructed discs. vs 3.0 mm for fused segments. Axial compression stiffness was 3.0 ± 0.9 kN/mm for intact compared to 1.2 ± 0.4 kN/mm for IPD reconstructed segments. Reconstructed disc ROM was 9.0° ± 3.7° in flexion-extension, 10.6° ± 3.4° in lateral bending and 2.8° ± 1.4° in axial torsion which was similar to intact values and significantly greater than respective fusion values (p<0.001). Mobile intact segments exhibited significantly greater rotation after fusion vs. their more rigid counterparts (p<0.05), however, intact motion was not related to motion after IPD reconstruction. The NZ and rotational stiffness followed similar trends. Differences in NZ between mobile and rigid intact specimens tended to decrease in the IPD reconstructed state. Conclusion The annulus sparing IPD generally reproduced the intact segment biomechanics in terms of ROM, NZ, and stiffness. Furthermore, the IPD reconstructed discs imparted stability by maintaining a small neutral zone. The IPD reconstructed discs were significantly less rigid than the fusion constructs and may be an attractive alternative for the treatment of DDD. PMID:19540816

  15. Solid radiographic fusion with a nonconstrained device 5 years after cervical arthroplasty.

    PubMed

    Heary, Robert F; Goldstein, Ira M; Getto, Katarzyna M; Agarwal, Nitin

    2014-12-01

    Cervical disc arthroplasty (CDA) has been gaining popularity as a surgical alternative to anterior cervical discectomy and fusion. Spontaneous fusion following a CDA is uncommon. A few anecdotal reports of heterotrophic ossification around the implant sites have been noted for the BRYAN, ProDisc-C, Mobi-C, PRESTIGE, and PCM devices. All CDA fusions reported to date have been in devices that are semiconstrained. The authors reported the case of a 56-year-old man who presented with left C-7 radiculopathy and neck pain for 10 weeks after an assault injury. There was evidence of disc herniation at the C6-7 level. He was otherwise healthy with functional scores on the visual analog scale (VAS, 4.2); neck disability index (NDI, 16); and the 36-item short form health survey (SF-36; physical component summary [PSC] score 43 and mental component summary [MCS] score 47). The patient underwent total disc replacement in which the DISCOVER Artificial Cervical Disc (DePuy Spine, Inc.) was used. The patient was seen at regular follow-up visits up to 60 months. At his 60-month follow-up visit, he had complete radiographic fusion at the C6-7 level with bridging trabecular bone and no motion at the index site on dynamic imaging. He was pain free, with a VAS score of 0, NDI score of 0, and SF-36 PCS and MCS scores of 61 and 55, respectively. Conclusions This is the first case report that identifies the phenomenon of fusion around a nonconstrained cervical prosthesis. Despite this unwanted radiographic outcome, the patient's clinical outcome was excellent.

  16. Characterization of HIV Recent Infection Among High-Risk Men at Public STI Clinics in Mumbai.

    PubMed

    Truong, Hong-Ha M; Fatch, Robin; Grant, Robert M; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hemangi; Kellogg, Timothy A; Lindan, Christina P

    2018-02-16

    We examined associations with HIV recent infection and estimated transmitted drug resistance (TDR) prevalence among 3345 men at sexually transmitted infection clinics in Mumbai (2002-2005). HIV seroincidence was 7.92% by the BED-CEIA and was higher at a clinic located near brothels (12.39%) than at a hospital-based clinic (3.94%). HIV recent infection was associated with a lifetime history of female sex worker (FSW) partners, HSV-2, genital warts, and gonorrhea. TDR prevalence among recent infection cases was 5.7%. HIV testing services near sex venues may enhance case detection among high-risk men who represent a bridging population between FSWs and the men's other sexual partners.

  17. Ultra-wideband directional sampler

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    The Ultra-Wideband (UWB) Directional Sampler is a four port device that combines the function of a directional coupler with a high speed sampler. Two of the four ports operate at a high sub-nanosecond speed, in "real time", and the other two ports operate at a slow millisecond-speed, in "equivalent time". A signal flowing inbound to either of the high speed ports is sampled and coupled, in equivalent time, to the adjacent equivalent time port while being isolated from the opposite equivalent time port. A primary application is for a time domain reflectometry (TDR) situation where the reflected pulse returns while the outbound pulse is still being transmitted, such as when the reflecting discontinuity is very close to the TDR apparatus.

  18. Rapid surface colony counts determination with three new miniaturised techniques.

    PubMed

    Malik, K A

    1977-01-01

    Three different miniaturised methods for the rapid surface viable counting are described. The methods were tried in parallel to seven different existing methods (Table 1) for viable counts and were found to be easier, quicker and insome cases more accurate. The techniques require about 10% of the material and time needed for conventional spread-plates method and the results were in no way inferior to that (Table 1 and 2). Mini agar discs were cut aseptically with an especially designed stainless steel agar disc cutter (25 mm internal and 28 mm external diameter, Fig. 1b) or with a test tube of similar diameter. The area of the resulted mini-agar-disc of 25 mm diameter was kept such (about 1/10th of the normal plate) that the ratio of the colony-bearing area to the inoculm remained the same as on big plates in spread-plate-method (Table 2). In normal Petri dishes (about 90 mm diameter) up to seven mini agar discs were possible to cut. Each small agar disc was seperated from the other mini-disc by a distance of at least 6 mm (Fig. 1a). The empty place around the disc was still enlarged during over drying of the plates and during incubation. This created complete isolation from the neighbouring disc. For micro-determination of surface viable counts 10 micronl from each dilution was delivered on a well-dired mini-disc with a piston micropipette. The inoculm was immediately spread on the whole mini-disc with a specially designed flame sterilizable platinum-Mini-spreader (Fig. 2a). No spinning of the plate was needed. Alternatively the dropping pipette and spreader was replaced by a calibrated platinum wire Loop-spreader (Fig. 2b). A loop of 3 mm internal diameter made from a platinum-iridium wire of 0.75 mm thickness proved most useful and carried a drop of 10 micronl. Differences especially in surface tension of various diluting fluids did not influence to drop of this size and no recalibration was needed for water and nutrient broth. The loop was further shaped to Loop-spreader form. From each bacterial suspension 10 micronl were carried and spread on each mini-disc. The method is useful for pathogenic organisms as the loop can readily be flame sterilized. For routine purposes where only approximate numbers of bacteria need to be known a still rapid semiquantitative method was deviced making use of a calibrated stainless steel Stamping-disc (Fig. 2c). A disc of 25mm diameter and 1 mm thickness delivered approximateyl 10 microlitres of supensions and was found to be most useful to stamp seven dilutions on a single plate. In collections and bacteriology laboratories where by conventional methods large number of plates are to be plated and counted the presented techniques could prove most convenient, rapid and economical.

  19. Organotypic three-dimensional assays based on human leiomyoma–derived matrices

    PubMed Central

    Dourado, Mauricio Rocha; Sundquist, Elias; Apu, Ehsanul Hoque; Alahuhta, Ilkka; Tuomainen, Katja; Vasara, Jenni; Al-Samadi, Ahmed

    2018-01-01

    Alongside cancer cells, tumours exhibit a complex stroma containing a repertoire of cells, matrix molecules and soluble factors that actively crosstalk between each other. Recognition of this multifaceted concept of the tumour microenvironment (TME) calls for authentic TME mimetics to study cancer in vitro. Traditionally, tumourigenesis has been investigated in non-human, three-dimensional rat type I collagen containing organotypic discs or by means of mouse sarcoma-derived gel, such as Matrigel®. However, the molecular compositions of these simplified assays do not properly simulate human TME. Here, we review the main properties and benefits of using human leiomyoma discs and their matrix Myogel for in vitro assays. Myoma discs are practical for investigating the invasion of cancer cells, as are cocultures of cancer and stromal cells in a stiff, hypoxic TME mimetic. Myoma discs contain soluble factors and matrix molecules commonly present in neoplastic stroma. In Transwell, IncuCyte, spheroid and sandwich assays, cancer cells move faster and form larger colonies in Myogel than in Matrigel®. Additionally, Myogel can replace Matrigel® in hanging-drop and tube-formation assays. Myogel also suits three-dimensional drug testing and extracellular vesicle interactions. To conclude, we describe the application of our myoma-derived matrices in 3D in vitro cancer assays. This article is part of the discussion meeting issue ‘Extracellular vesicles and the tumour microenvironment’. PMID:29158312

  20. Organotypic three-dimensional assays based on human leiomyoma-derived matrices.

    PubMed

    Salo, Tuula; Dourado, Mauricio Rocha; Sundquist, Elias; Apu, Ehsanul Hoque; Alahuhta, Ilkka; Tuomainen, Katja; Vasara, Jenni; Al-Samadi, Ahmed

    2018-01-05

    Alongside cancer cells, tumours exhibit a complex stroma containing a repertoire of cells, matrix molecules and soluble factors that actively crosstalk between each other. Recognition of this multifaceted concept of the tumour microenvironment (TME) calls for authentic TME mimetics to study cancer in vitro Traditionally, tumourigenesis has been investigated in non-human, three-dimensional rat type I collagen containing organotypic discs or by means of mouse sarcoma-derived gel, such as Matrigel ® However, the molecular compositions of these simplified assays do not properly simulate human TME. Here, we review the main properties and benefits of using human leiomyoma discs and their matrix Myogel for in vitro assays. Myoma discs are practical for investigating the invasion of cancer cells, as are cocultures of cancer and stromal cells in a stiff, hypoxic TME mimetic. Myoma discs contain soluble factors and matrix molecules commonly present in neoplastic stroma. In Transwell, IncuCyte, spheroid and sandwich assays, cancer cells move faster and form larger colonies in Myogel than in Matrigel ® Additionally, Myogel can replace Matrigel ® in hanging-drop and tube-formation assays. Myogel also suits three-dimensional drug testing and extracellular vesicle interactions. To conclude, we describe the application of our myoma-derived matrices in 3D in vitro cancer assays.This article is part of the discussion meeting issue 'Extracellular vesicles and the tumour microenvironment'. © 2017 The Authors.

  1. In vitro biomechanical comparison after fixed- and mobile-core artificial cervical disc replacement versus fusion

    PubMed Central

    Lou, Jigang; Li, Yuanchao; Wang, Beiyu; Meng, Yang; Wu, Tingkui; Liu, Hao

    2017-01-01

    Abstract In vitro biomechanical analysis after cervical disc replacement (CDR) with a novel artificial disc prosthesis (mobile core) was conducted and compared with the intact model, simulated fusion, and CDR with a fixed-core prosthesis. The purpose of this experimental study was to analyze the biomechanical changes after CDR with a novel prosthesis and the differences between fixed- and mobile-core prostheses. Six human cadaveric C2–C7 specimens were biomechanically tested sequentially in 4 different spinal models: intact specimens, simulated fusion, CDR with a fixed-core prosthesis (Discover, DePuy), and CDR with a mobile-core prosthesis (Pretic-I, Trauson). Moments up to 2 Nm with a 75 N follower load were applied in flexion–extension, left and right lateral bending, and left and right axial rotation. The total range of motion (ROM), segmental ROM, and adjacent intradiscal pressure (IDP) were calculated and analyzed in 4 different spinal models, as well as the differences between 2 disc prostheses. Compared with the intact specimens, the total ROM, segmental ROM, and IDP at the adjacent segments showed no significant difference after arthroplasty. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment (C5/6) and total ROM than CDR with a fixed-core prosthesis (P > .05). Besides, the difference in IDP at C4/5 after CDR with 2 prostheses was without statistical significance in all the directions of motion. However, the IDP at C6/7 after CDR with a mobile-core prosthesis was lower than CDR with a fixed-core prosthesis in flexion, extension, and lateral bending, with significant difference (P < .05), but not under axial rotation. CDR with a novel prosthesis was effective to maintain the ROM at the target segment and did not affect the ROM and IDP at the adjacent segments. Moreover, CDR with a mobile-core prosthesis presented a little higher values of target segment and total ROM, but lower IDP at the inferior adjacent segment than CDR with a fixed-core prosthesis. PMID:29019902

  2. Topology-guided deformable registration with local importance preservation for biomedical images

    NASA Astrophysics Data System (ADS)

    Zheng, Chaojie; Wang, Xiuying; Zeng, Shan; Zhou, Jianlong; Yin, Yong; Feng, Dagan; Fulham, Michael

    2018-01-01

    The demons registration (DR) model is well recognized for its deformation capability. However, it might lead to misregistration due to erroneous diffusion direction when there are no overlaps between corresponding regions. We propose a novel registration energy function, introducing topology energy, and incorporating a local energy function into the DR in a progressive registration scheme, to address these shortcomings. The topology energy that is derived from the topological information of the images serves as a direction inference to guide diffusion transformation to retain the merits of DR. The local energy constrains the deformation disparity of neighbouring pixels to maintain important local texture and density features. The energy function is minimized in a progressive scheme steered by a topology tree graph and we refer to it as topology-guided deformable registration (TDR). We validated our TDR on 20 pairs of synthetic images with Gaussian noise, 20 phantom PET images with artificial deformations and 12 pairs of clinical PET-CT studies. We compared it to three methods: (1) free-form deformation registration method, (2) energy-based DR and (3) multi-resolution DR. The experimental results show that our TDR outperformed the other three methods in regard to structural correspondence and preservation of the local important information including texture and density, while retaining global correspondence.

  3. Pretreatment drug resistance in a large countrywide Ethiopian HIV-1C cohort: a comparison of Sanger and high-throughput sequencing.

    PubMed

    Telele, Nigus Fikrie; Kalu, Amare Worku; Gebre-Selassie, Solomon; Fekade, Daniel; Abdurahman, Samir; Marrone, Gaetano; Neogi, Ujjwal; Tegbaru, Belete; Sönnerborg, Anders

    2018-05-15

    Baseline plasma samples of 490 randomly selected antiretroviral therapy (ART) naïve patients from seven hospitals participating in the first nationwide Ethiopian HIV-1 cohort were analysed for surveillance drug resistance mutations (sDRM) by population based Sanger sequencing (PBSS). Also next generation sequencing (NGS) was used in a subset of 109 baseline samples of patients. Treatment outcome after 6- and 12-months was assessed by on-treatment (OT) and intention-to-treat (ITT) analyses. Transmitted drug resistance (TDR) was detected in 3.9% (18/461) of successfully sequenced samples by PBSS. However, NGS detected sDRM more often (24%; 26/109) than PBSS (6%; 7/109) (p = 0.0001) and major integrase strand transfer inhibitors (INSTI) DRMs were also found in minor viral variants from five patients. Patients with sDRM had more frequent treatment failure in both OT and ITT analyses. The high rate of TDR by NGS and the identification of preexisting INSTI DRMs in minor wild-type HIV-1 subtype C viral variants infected Ethiopian patients underscores the importance of TDR surveillance in low- and middle-income countries and shows added value of high-throughput NGS in such studies.

  4. A PC based time domain reflectometer for space station cable fault isolation

    NASA Technical Reports Server (NTRS)

    Pham, Michael; McClean, Marty; Hossain, Sabbir; Vo, Peter; Kouns, Ken

    1994-01-01

    Significant problems are faced by astronauts on orbit in the Space Station when trying to locate electrical faults in multi-segment avionics and communication cables. These problems necessitate the development of an automated portable device that will detect and locate cable faults using the pulse-echo technique known as Time Domain Reflectometry. A breadboard time domain reflectometer (TDR) circuit board was designed and developed at the NASA-JSC. The TDR board works in conjunction with a GRiD lap-top computer to automate the fault detection and isolation process. A software program was written to automatically display the nature and location of any possible faults. The breadboard system can isolate open circuit and short circuit faults within two feet in a typical space station cable configuration. Follow-on efforts planned for 1994 will produce a compact, portable prototype Space Station TDR capable of automated switching in multi-conductor cables for high fidelity evaluation. This device has many possible commercial applications, including commercial and military aircraft avionics, cable TV, telephone, communication, information and computer network systems. This paper describes the principle of time domain reflectometry and the methodology for on-orbit avionics utility distribution system repair, utilizing the newly developed device called the Space Station Time Domain Reflectometer (SSTDR).

  5. Measuring societal effects of transdisciplinary research projects: design and application of an evaluation method.

    PubMed

    Walter, Alexander I; Helgenberger, Sebastian; Wiek, Arnim; Scholz, Roland W

    2007-11-01

    Most Transdisciplinary Research (TdR) projects combine scientific research with the building of decision making capacity for the involved stakeholders. These projects usually deal with complex, societally relevant, real-world problems. This paper focuses on TdR projects, which integrate the knowledge of researchers and stakeholders in a collaborative transdisciplinary process through structured methods of mutual learning. Previous research on the evaluation of TdR has insufficiently explored the intended effects of transdisciplinary processes on the real world (societal effects). We developed an evaluation framework for assessing the societal effects of transdisciplinary processes. Outputs (measured as procedural and product-related involvement of the stakeholders), impacts (intermediate effects connecting outputs and outcomes) and outcomes (enhanced decision making capacity) are distinguished as three types of societal effects. Our model links outputs and outcomes of transdisciplinary processes via the impacts using a mediating variables approach. We applied this model in an ex post evaluation of a transdisciplinary process. 84 out of 188 agents participated in a survey. The results show significant mediation effects of the two impacts "network building" and "transformation knowledge". These results indicate an influence of a transdisciplinary process on the decision making capacity of stakeholders, especially through social network building and the generation of knowledge relevant for action.

  6. Soil nematode assemblages as bioindicators of radiation impact in the Chernobyl Exclusion Zone.

    PubMed

    Lecomte-Pradines, C; Bonzom, J-M; Della-Vedova, C; Beaugelin-Seiller, K; Villenave, C; Gaschak, S; Coppin, F; Dubourg, N; Maksimenko, A; Adam-Guillermin, C; Garnier-Laplace, J

    2014-08-15

    In radioecology, the need to understand the long-term ecological effects of radioactive contamination has been emphasised. This requires that the health of field populations is evaluated and linked to an accurate estimate of received radiological dose. The aim of the present study was to assess the effects of current radioactive contamination on nematode assemblages at sites affected by the fallout from the Chernobyl accident. First, we estimated the total dose rates (TDRs) absorbed by nematodes, from measured current soil activity concentrations, Dose Conversion Coefficients (DCCs, calculated using EDEN software) and soil-to-biota concentration ratios (from the ERICA tool database). The impact of current TDRs on nematode assemblages was then evaluated. Nematodes were collected in spring 2011 from 18 forest sites in the Chernobyl Exclusion Zone (CEZ) with external gamma dose rates, measured using radiophotoluminescent dosimeters, varying from 0.2 to 22 μGy h(-1). These values were one order of magnitude below the TDRs. A majority of bacterial-, plant-, and fungal-feeding nematodes and very few of the disturbance sensitive families were identified. No statistically significant association was observed between TDR values and nematode total abundance or the Shannon diversity index (H'). The Nematode Channel Ratio (which defines the relative abundance of bacterial- versus fungal-feeding nematodes) decreased significantly with increasing TDR, suggesting that radioactive contamination may influence nematode assemblages either directly or indirectly by modifying their food resources. A greater Maturity Index (MI), usually characterising better soil quality, was associated with higher pH and TDR values. These results suggest that in the CEZ, nematode assemblages from the forest sites were slightly impacted by chronic exposure at a predicted TDR of 200 μGy h(-1). This may be imputable to a dominant proportion of pollutant resistant nematodes in all sites. This might result from a selection at the expense of sensitive species after the accident. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Data Publishing and Sharing Via the THREDDS Data Repository

    NASA Astrophysics Data System (ADS)

    Wilson, A.; Caron, J.; Davis, E.; Baltzer, T.

    2007-12-01

    The terms "Team Science" and "Networked Science" have been coined to describe a virtual organization of researchers tied via some intellectual challenge, but often located in different organizations and locations. A critical component to these endeavors is publishing and sharing of content, including scientific data. Imagine pointing your web browser to a web page that interactively lets you upload data and metadata to a repository residing on a remote server, which can then be accessed by others in a secure fasion via the web. While any content can be added to this repository, it is designed particularly for storing and sharing scientific data and metadata. Server support includes uploading of data files that can subsequently be subsetted, aggregrated, and served in NetCDF or other scientific data formats. Metadata can be associated with the data and interactively edited. The THREDDS Data Repository (TDR) is a server that provides client initiated, on demand, location transparent storage for data of any type that can then be served by the THREDDS Data Server (TDS). The TDR provides functionality to: * securely store and "own" data files and associated metadata * upload files via HTTP and gridftp * upload a collection of data as single file * modify and restructure repository contents * incorporate metadata provided by the user * generate additional metadata programmatically * edit individual metadata elements The TDR can exist separately from a TDS, serving content via HTTP. Also, it can work in conjunction with the TDS, which includes functionality to provide: * access to data in a variety of formats via -- OPeNDAP -- OGC Web Coverage Service (for gridded datasets) -- bulk HTTP file transfer * a NetCDF view of datasets in NetCDF, OPeNDAP, HDF-5, GRIB, and NEXRAD formats * serving of very large volume datasets, such as NEXRAD radar * aggregation into virtual datasets * subsetting via OPeNDAP and NetCDF Subsetting services This talk will discuss TDR/TDS capabilities as well as how users can install this software to create their own repositories.

  8. TDR measurements looking for complex dielectric permittivity and complex magnetic permeability in lossy materials

    NASA Astrophysics Data System (ADS)

    Persico, Raffaele

    2017-04-01

    TDR probes can be exploited for the measure of the electromagnetic characteristics of the soil, or of any penetrable material. They are commonly exploited as instruments for the measure of the propagation velocity of the electromagnetic waves in the probed medium [1], in its turn useful for the proper focusing of GPR data [2-5]. However, a more refined hardware and processing can allow to extrapolate from these probes also the discrimination between dielectric and magnetic characteristics of the material under test, which can be relevant for a better interpretation of the buried scenario or in order to infer physical-chemical characteristics of the material at hand. This requires a TDR probe that can work in frequency domain, and in particular that allows to retrieve the reflection coefficient at the air soil interface. It has been already shown [6] that in lossless cases this can be promising. In the present contribution, it will be shown at the EGU conference that it is possible to look for both the relative complex permittivity and the relative magnetic permeability of the probed material, on condition that the datum has an acceptable SNR and that some diversity of information is guaranteed, either by multifrequency data or by a TDR that can prolong its arms in the soil. References [1] F. Soldovieri, G. Prisco, R. Persico, Application of Microwave Tomography in Hydrogeophysics: some examples, Vadose Zone Journal, vol. 7, n. 1 pp. 160-170, Feb. 2008. [2] I. Catapano, L. Crocco, R. Persico, M. Pieraccini, F. Soldovieri, "Linear and Nonlinear Microwave Tomography Approaches for Subsurface Prospecting: Validation on Real Data", IEEE Trans. on Antennas and Wireless Propagation Letters, vol. 5, pp. 49-53, 2006. [3] G. Leucci, N. Masini, R. Persico, F. Soldovieri." GPR and sonic tomography for structural restoration : the case of the Cathedral of Tricarico", Journal of Geophysics and Engineering, vol. 8, pp. S76-S92, Aug. 2011. [4] S. Piscitelli, E. Rizzo, F. Cristallo, V. Lapenna, L. Crocco, R. Persico, F. Soldovieri, GPR and Microwave Tomography for Detecting shallow Cavities in the Historical Area of Sassi of Matera (Southern Italy), Near Surface Geophysics, vol. 5, pp. 275-285, 2007. [5] R. Persico, Introduction to Ground Penetrating Radar: Inverse Scattering and data processing. Wiley, 2014, ISBN 9781118305003. [6] R. Persico, Preliminary experiments about the measure of the magnetic properties of a material by means of TDR probes, Proc. EGU Meeting, Vienna, April 17-22, 2016

  9. [Influence of pacing site on myocardial transmural dispersion of repolarization in intact normal and dilated cardiomyopathy dogs].

    PubMed

    Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin

    2003-12-25

    In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged MAPD of all the three layers of the myocardium (P<0.05) with the character that mid-layer MAPD was the longest and subepicardial MAPD was the shortest following subendocardial MAPD. At the same time, TDR prolonged from 26.75 ms at RV-Endo pacing to 37.54 ms at BiV pacing and to 47.16 ms at LV-Epi pacing (P<0.001). Meanwhile in surface ECG, BiV and LV-Epi pacing resulted in a longer Tp-Te) interval compared with RV-Endo pacing (P<0.01), without parallel QT interval prolongation. Furthermore, all the DCM-CHF model dogs showed manifestations of congestive heart failure and enlargement of left ventricles. Based on the lengthening of mid-layer MAPD from 257.35 ms to 276.30 ms (P<0.0001) and increase of TDR from 27.58 ms to 33.80 ms (P equals;0.002) in DCM-CHF model due to the structural disorders of myocardium compared with the normal dog, LV-Epi and BiV pacing also led to the effect of prolonging MAPD of three layers of the myocardium and enlarging TDR. From these results we make the conclusions that prolongation of MAPD of subendocardial, subepicardial and mid-layer myocardium and increase in TDR during pacing participating of LV (LV-Epi, BiV) may contribute to the formation of unidirectional block and reentry, which play roles or at least are the high risk factors in the development of malignant ventricular arrhythmia, especially in case of structural disorders of myocardium. These findings must be considered seriously when ventricular resynchronization therapy is performed to congestive heart failure patients.

  10. Theseus: tethered distributed robotics (TDR)

    NASA Astrophysics Data System (ADS)

    Digney, Bruce L.; Penzes, Steven G.

    2003-09-01

    The Defence Research and Development Canada's (DRDC) Autonomous Intelligent System's program conducts research to increase the independence and effectiveness of military vehicles and systems. DRDC-Suffield's Autonomous Land Systems (ALS) is creating new concept vehicles and autonomous control systems for use in outdoor areas, urban streets, urban interiors and urban subspaces. This paper will first give an overview of the ALS program and then give a specific description of the work being done for mobility in urban subspaces. Discussed will be the Theseus: Thethered Distributed Robotics (TDR) system, which will not only manage an unavoidable tether but exploit it for mobility and navigation. Also discussed will be the prototype robot called the Hedgehog, which uses conformal 3D mobility in ducts, sewer pipes, collapsed rubble voids and chimneys.

  11. Ultra-wideband directional sampler

    DOEpatents

    McEwan, T.E.

    1996-05-14

    The Ultra-Wideband (UWB) Directional Sampler is a four port device that combines the function of a directional coupler with a high speed sampler. Two of the four ports operate at a high sub-nanosecond speed, in ``real time``, and the other two ports operate at a slow millisecond-speed, in ``equivalent time``. A signal flowing inbound to either of the high speed ports is sampled and coupled, in equivalent time, to the adjacent equivalent time port while being isolated from the opposite equivalent time port. A primary application is for a time domain reflectometry (TDR) situation where the reflected pulse returns while the outbound pulse is still being transmitted, such as when the reflecting discontinuity is very close to the TDR apparatus. 3 figs.

  12. Percutaneous Endoscopic Cervical Discectomy (PECD): An Analysis of Outcome, Causes of Reoperation.

    PubMed

    Oh, Hyeong Seok; Hwang, Byeong-Wook; Park, Sang-Joon; Hsieh, Chang-Sheng; Lee, Sang-Ho

    2017-06-01

    Percutaneous endoscopic cervical discectomy (PECD) is regarded as an effective treatment modality in cervical disc herniation, including radicular pain and lateral location of disc herniation. This study aimed to evaluate the clinical and radiologic outcomes of PECD along with the causes of reoperation and the technique itself. Between January 2007 and November 2012, 101 patients underwent PECD at the Busan Wooridul Hospital. Three patients underwent a 2-level PECD. The mean follow-up period was 34 months (range, 18-72 months). The mean age was 46.1 years; the most common operation was at the C5-C6 level (n = 45), followed by C6-C7 (n = 35), C4-C5 (n = 16), and C3-C4 (n = 8). The clinical outcomes were evaluated via the visual analog scale of the neck and arm according to the Neck Disability Index and the modified Macnab criteria. Among 101 patients, 12 underwent an additional operation at the index level. Five patients had aggravated stenosis by disc height narrowing, 4 had recurred disc, 2 had remained disc, and 1 had sustained symptoms. After PECD, there was a significant improvement in the visual analog scale and Neck Disability Index scores (P < 0.001). According to the modified Macnab criteria, excellent concordance was achieved in 65 patients, good in 22, fair in 2, and poor in 12. The reoperation performed on 12 patients improved their clinical outcomes. The mean duration was 4.8 months (2 days to 18 months) until reoperation. There were 3 PECD revisions, 3 artificial disc replacements, 2 corpectomies, 2 anterior cervical discectomies and fusion with cages, and 2 transfers to another hospital. The common feature was older age (P = 0.016) and male sex (P = 0.031). Preoperative radiologic findings were characterized by the foraminal disc (P = 0.04), disc degeneration at the index level (P = 0.05), combined bony spur (P = 0.001), concomitant adjacent level degeneration (P = 0.019), cervical kyphosis (P = 0.015), and segmental angle deterioration after PECD (P = 0.038). No statistical correlation was seen between the operation level and herniation size (P > 0.05). In total, 87% patients showed successful clinical outcome. Poor and fair outcomes at initial PECD were overcome by revision surgery, which improved outcomes. Although PECD is a promising minimally invasive procedure for cervical disc treatment, the indications for PECD should be considered carefully. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Research priorities for the environment, agriculture and infectious diseases of poverty.

    PubMed

    2013-01-01

    This report reviews the connections between environmental change, modern agricultural practices and the occurrence of infectious diseases - especially those of poverty; proposes a multi-criteria decision analysis approach to determining the key research priorities; and explores the benefits and limitations of a more systems-based approach to conceptualizing and investigating the problem. The report is the output of the Thematic Reference Group on Environment, Agriculture and Infectious Diseases of Poverty (TRG 4), part of an independent think tank of international experts, established and funded by the Special Programme for Research and Training in Tropical Diseases (TDR) to identify key research priorities through review of research evidence and input from stakeholder consultations. The report concludes that mitigating the outcomes on human health will require far-reaching strategies - spanning the environment, climate, agriculture, social-ecological, microbial and public-health sectors; as well as inter-disciplinary research and intersectoral action. People will also need to modify their way of thinking and engage beyond their own specialities, since the challenges are systemic and are amplified by the increasing inter-connectedness of human populations. This is one of a series of disease and thematic reference group reports that have come out of the TDR Think Tank, all of which have contributed to the development of the Global Report for Research on Infectious Diseases of Poverty, available at www.who.int/tdr/capacity/global_report.

  14. Subsurface Investigation of the Neogene Mygdonian Basin, Greece Using Magnetic Data

    NASA Astrophysics Data System (ADS)

    Ibraheem, Ismael M.; Gurk, Marcus; Tougiannidis, Nikolaos; Tezkan, Bülent

    2018-02-01

    A high-resolution ground and marine magnetic survey was executed to determine the structure of the subsurface and the thickness of the sedimentary cover in the Mygdonian Basin. A spacing of approximately 250 m or 500 m between measurement stations was selected to cover an area of 15 km × 22 km. Edge detectors such as total horizontal derivative (THDR), analytic signal (AS), tilt derivative (TDR), enhanced total horizontal gradient of tilt derivative (ETHDR) were applied to map the subsurface structure. Depth was estimated by power spectrum analysis, tilt derivative, source parameter imaging (SPI), and 2D-forward modeling techniques. Spectral analysis and SPI suggest a depth to the basement ranging from near surface to 600 m. For some selected locations, depth was also calculated using the TDR technique suggesting depths from 160 to 400 m. 2D forward magnetic modeling using existing boreholes as constraints was carried out along four selected profiles and confirmed the presence of alternative horsts and grabens formed by parallel normal faults. The dominant structural trends inferred from THDR, AS, TDR, and ETHDR are N-S, NW-SE, NE-SW and E-W. This corresponds with the known structural trends in the area. Finally, a detailed structural map showing the magnetic blocks and the structural architecture of the Mygdonian Basin was drawn up by collating all of the results.

  15. The Black Record: A Selective Discography of Afro-Americana on Audio Discs Held by the Audio/Visual Department, John M. Olin Library.

    ERIC Educational Resources Information Center

    Dain, Bernice, Comp.; Nevin, David, Comp.

    The present revised and expanded edition of this document is an inclusive cumulation. A few items have been included which are on order as new to the collection or as replacements. This discography is intended to serve primarily as a local user's guide. The call number preceding each entry is based on the Audio-Visual Department's own, unique…

  16. KSC-07pd3643

    NASA Image and Video Library

    2007-12-14

    KENNEDY SPACE CENTER, FLA. -- In the cryogenic test bed facility at NASA's Kennedy Space Center, Time Domain Reflectometry, or TDR, instrumentation is being exposed to "wet" super-cold temperatures for identifying the signature of a cryogenic environment and calibrating the TDR equipment. The equipment will be used at the launch pad to test a procedure identical to a tanking test on space shuttle Atlantis' external tank planned for Dec. 18. The shuttle's planned launches on Dec. 6 and Dec. 9 were postponed because of false readings from the part of the engine cut-off, or ECO, sensor system that monitors the liquid hydrogen section of the tank. The liftoff date from NASA's Kennedy Space Center, Florida, is now targeted for Jan. 10, depending on the resolution of the problem in the fuel sensor system. Photo credit: NASA/Kim Shiflett

  17. KSC-07pd3639

    NASA Image and Video Library

    2007-12-14

    KENNEDY SPACE CENTER, FLA. -- In the cryogenic test bed facility at NASA's Kennedy Space Center, Time Domain Reflectometry, or TDR, instrumentation is being exposed to "wet" super-cold temperatures for identifying the signature of a cryogenic environment and calibrating the TDR equipment. The equipment will be used at the launch pad to test a procedure identical to a tanking test on space shuttle Atlantis' external tank planned for Dec. 18. The shuttle's planned launches on Dec. 6 and Dec. 9 were postponed because of false readings from the part of the engine cut-off, or ECO, sensor system that monitors the liquid hydrogen section of the tank. The liftoff date from NASA's Kennedy Space Center, Florida, is now targeted for Jan. 10, depending on the resolution of the problem in the fuel sensor system. Photo credit: NASA/Kim Shiflett

  18. KSC-07pd3640

    NASA Image and Video Library

    2007-12-14

    KENNEDY SPACE CENTER, FLA. -- In the cryogenic test bed facility at NASA's Kennedy Space Center, Time Domain Reflectometry, or TDR, instrumentation is being exposed to "wet" super-cold temperatures for identifying the signature of a cryogenic environment and calibrating the TDR equipment. The equipment will be used at the launch pad to test a procedure identical to a tanking test on space shuttle Atlantis' external tank planned for Dec. 18. The shuttle's planned launches on Dec. 6 and Dec. 9 were postponed because of false readings from the part of the engine cut-off, or ECO, sensor system that monitors the liquid hydrogen section of the tank. The liftoff date from NASA's Kennedy Space Center, Florida, is now targeted for Jan. 10, depending on the resolution of the problem in the fuel sensor system. Photo credit: NASA/Kim Shiflett

  19. KSC-07pd3641

    NASA Image and Video Library

    2007-12-14

    KENNEDY SPACE CENTER, FLA. -- In the cryogenic test bed facility at NASA's Kennedy Space Center, Time Domain Reflectometry, or TDR, instrumentation is being exposed to "wet" super-cold temperatures for identifying the signature of a cryogenic environment and calibrating the TDR equipment. The equipment will be used at the launch pad to test a procedure identical to a tanking test on space shuttle Atlantis' external tank planned for Dec. 18. The shuttle's planned launches on Dec. 6 and Dec. 9 were postponed because of false readings from the part of the engine cut-off, or ECO, sensor system that monitors the liquid hydrogen section of the tank. The liftoff date from NASA's Kennedy Space Center, Florida, is now targeted for Jan. 10, depending on the resolution of the problem in the fuel sensor system. Photo credit: NASA/Kim Shiflett

  20. Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-ohm High-Speed Cables

    NASA Technical Reports Server (NTRS)

    Theofylaktos, Onoufrios; Warner, Joseph D.

    2012-01-01

    In the radiofrequency (RF) world, in order to characterize cables that do not conform to the typical 50-omega impedance, a time domain reflectometer (TDR) would probably be the simplest and quickest tool to attain this goal. In the real world, not every engineer has a TDR at their disposal; however, they most likely have a network analyzer available. Given a generic 50-omega vector network analyzer (VNA), we would like to make S-parameter measurements for non-50-omega devices (DUTs). For that, we utilize RF balanced/unbalanced transformers (called baluns for short), which are primarily used to match the impedance between the two VNA ports and the DUT's input and output ports, for the two-port S-parameter measurements.

  1. Computation models simulating notochordal cell extinction during early ageing of an intervertebral disc.

    PubMed

    Louman-Gardiner, K M; Coombe, D; Hunter, C J

    2011-12-01

    Lower back pain due to intervertebral disc (IVD) degeneration is a prevalent problem which drastically affects the quality of life of millions of sufferers. Healthy IVDs begin with high populations of notochordal cells in the nucleus pulposus, while by the second stage of degeneration, these cells will be replaced by chondrocyte-like cells. Because the IVD is avascular, these cells rely on passive diffusion of nutrients to survive. It is thought that this transition in cell phenotype causes the shift of the IVD's physical properties, which impede the flow of nutrients. Our computational model of the IVD illustrates its ability to simulate the evolving chemical and mechanical environments occurring during the early ageing process. We demonstrate that, due to the insufficient nutrient supply and accompanying changes in physical properties of the IVD, there was a resultant exponential decay in the number of notochordal cells over time.

  2. The Application of Vibration Accelerations in the Assessment of Average Friction Coefficient of a Railway Brake Disc

    NASA Astrophysics Data System (ADS)

    Sawczuk, Wojciech

    2017-06-01

    Due to their wide range of friction characteristics resulting from the application of different friction materials and good heat dissipation conditions, railway disc brakes have long replaced block brakes in many rail vehicles. A block brake still remains in use, however, in low speed cargo trains. The paper presents the assessment of the braking process through the analysis of vibrations generated by the components of the brake system during braking. It presents a possibility of a wider application of vibroacoustic diagnostics (VA), which aside from the assessment of technical conditions (wear of brake pads) also enables the determination of the changes of the average friction coefficient as a function of the braking onset speed. Vibration signals of XYZ were measured and analyzed. The analysis of the results has shown that there is a relation between the values of the point measures and the wear of the brake pads.

  3. The fundamentals of biotribology and its application to spine arthroplasty

    PubMed Central

    Harper, Megan L.; Dooris, Andrew; Paré, Philippe E.

    2009-01-01

    The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results. PMID:25802638

  4. Quality of systematic reviews: an example of studies comparing artificial disc replacement with fusion in the cervical spine.

    PubMed

    Tashani, Osama A; El-Tumi, Hanan; Aneiba, Khaled

    2015-01-01

    Cervical artificial disc replacement (C-ADR) is now an alternative to anterior cervical discectomy and fusion (ACDF). Many studies have evaluated the efficacy of C-ADR compared with ACDF. This led to a series of systematic reviews and meta-analyses to evaluate the evidence of the superiority of one intervention against the other. The aim of the study presented here was to evaluate the quality of these reviews and meta-analyses. Medline via Ovid, Embase, and Cochrane Library were searched using the keywords: (total disk replacement, prosthesis, implantation, discectomy, and arthroplasty) AND (cervical vertebrae, cervical spine, and spine) AND (systematic reviews, reviews, and meta-analysis). Screening and data extraction were conducted by two reviewers independently. Two reviewers then assessed the quality of the selected reviews and meta-analysis using 11-item AMSTAR score which is a validated measurement tool to assess the methodological quality of systematic reviews. Screening of full reports of 46 relevant abstracts resulted in the selection of 15 systematic reviews and/or meta-analyses as eligible for this study. The two reviewers' inter-rater agreement level was high as indicated by kappa of >0.72. The AMSTAR score of the reviews ranged from 3 to 11. Only one study (a Cochrane review) scored 100% (AMSTAR 11). Five studies scored below (AMSTAR 5) indicating low-quality reviews. The most significant drawbacks of reviews of a score below 5 were not using an extensive search strategy, failure to use the scientific quality of the included studies appropriately in formulating a conclusion, not assessing publication bias, and not reporting the excluded studies. With a significant exception of a Cochrane review, the methodological quality of systematic reviews evaluating the evidence of C-ADR versus ACDF has to be improved.

  5. Improved Method of Locating Defects in Wiring Insulation

    NASA Technical Reports Server (NTRS)

    Greulich, Owen R.

    2004-01-01

    An improved method of locating small breaches in insulation on electrical wires combines aspects of the prior dielectric withstand voltage (DWV) and time-domain reflectometry (TDR) methods. The method was invented to satisfy a need for reliably and quickly locating insulation defects in spacecraft, aircraft, ships, and other complex systems that contain large amounts of wiring, much of it enclosed in structures that make it difficult to inspect. In the DWV method, one applies a predetermined potential (usually 1.5 kV DC) to the wiring and notes whether the voltage causes any arcing between the wiring and ground. The DWV method does not provide an indication of the location of the defect (unless, in an exceptional case, the arc happens to be visible). In addition, if there is no electrically conductive component at ground potential within about 0.010 in. (approximately equal to 0.254 mm) of the wire at the location of an insulation defect, then the DWV method does not provide an indication of the defect. Moreover, one does not have the option to raise the potential in an effort to increase the detectability of such a defect because doing so can harm previously undamaged insulation. In the TDR method as practiced heretofore, one applies a pulse of electricity having an amplitude of less than 25 V to a wire and measures the round-trip travel time for the reflection of the pulse from a defect. The distance along the wire from the point of application of the pulse to the defect is then calculated as the product of half the round-trip travel time and the characteristic speed of a propagation of an electromagnetic signal in the wire. While the TDR method as practiced heretofore can be used to locate a short or open circuit, it does not ordinarily enable one to locate a small breach in insulation because the pulse voltage is too low to cause arcing and thus too low to induce an impedance discontinuity large enough to generate a measurable reflection. The present improved method overcomes the weaknesses of both the prior DWV and the prior TDR method.

  6. Projecting the epidemiological effect, cost-effectiveness and transmission of HIV drug resistance in Vietnam associated with viral load monitoring strategies.

    PubMed

    Pham, Quang Duy; Wilson, David P; Nguyen, Thuong Vu; Do, Nhan Thi; Truong, Lien Xuan; Nguyen, Long Thanh; Zhang, Lei

    2016-05-01

    The objective of this study was to investigate the potential epidemiological impact of viral load (VL) monitoring and its cost-effectiveness in Vietnam, where transmitted HIV drug resistance (TDR) prevalence has increased from <5% to 5%-15% in the past decade. Using a population-based mathematical model driven by data from Vietnam, we simulated scenarios of various combinations of VL testing coverage, VL thresholds for second-line ART initiation and availability of HIV drug-resistance tests. We assessed the cost per disability-adjusted life year (DALY) averted for each scenario. Projecting expected ART scale-up levels, to approximately double the number of people on ART by 2030, will lead to an estimated 18 510 cases (95% CI: 9120-34 600 cases) of TDR and 55 180 cases (95% CI: 40 540-65 900 cases) of acquired drug resistance (ADR) in the absence of VL monitoring. This projection corresponds to a TDR prevalence of 16% (95% CI: 11%-24%) and ADR of 18% (95% CI: 15%-20%). Annual or biennial VL monitoring with 30% coverage is expected to relieve 12%-31% of TDR (2260-5860 cases), 25%-59% of ADR (9620-22 650 cases), 2%-6% of HIV-related deaths (360-880 cases) and 19 270-51 400 DALYs during 2015-30. The 30% coverage of VL monitoring is estimated to cost US$4848-5154 per DALY averted. The projected additional cost for implementing this strategy is US$105-268 million over 2015-30. Our study suggests that a programmatically achievable 30% coverage of VL monitoring can have considerable benefits for individuals and leads to population health benefits by reducing the overall national burden of HIV drug resistance. It is marginally cost-effective according to common willingness-to-pay thresholds. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Root zone soil water dynamics and its effects on above ground biomass in cellulosic and grain based bioenergy crops of Midwest USA

    NASA Astrophysics Data System (ADS)

    Bhardwaj, A. K.; Hamilton, S. K.; van Dam, R. L.; Diker, K.; Basso, B.; Glbrc-Sustainability Thrust-4. 3 Biogeochemistry

    2010-12-01

    Root-zone soil moisture constitutes an important variable for hydrological and agronomic models. In agriculture, crop yields are directly related to soil moisture, levels that are most important in the root zone area of the soil. One of the most accurate in-situ methods that has established itself as a recognized standard around the world uses Time Domain Reflectometry (TDR) to determine volumetric water content of the soil. We used automated field-to-desk TDR based systems to monitor temporal (1-hr interval) soil moisture variability in 10 different bioenergy cropping systems at the Great Lakes Bioenergy Research Center’s (GLBRC) sustainability research site in south western Michigan, U.S.A. These crops range from high-diversity, low-input grass mixes to low-diversity, high-input crop monocultures. We equipped the 28 x 40 m vegetation plots with 30 cm long TDR probes at seven depths from 10 cm to 1.25 m below surface. The parent material at the site consists of coarse sandy glacial tills in which a soil with an approximately 50cm thick A-Bt horizon has developed. Additional equipment permanently installed for each system includes soil moisture access tubes, multi-depth temperature sensors, and multi-electrode resistivity arrays. The access tubes were monitored using a portable TDR system at bi-weekly intervals. 2D dipole-dipole electrical resistivity tomography (ERT) data are collected in 4-week intervals, while a subset of the electrodes is used for bi-hourly monitoring. The continuous scans (1 hr) provided us the real time changes in water content, replenishment and depletion, providing indications of water uptake by plant roots and potential seasonal water limitation of biomass accumulation. The results show significant seasonal variations between the crops and cropping systems. Significant relationships were observed between soil moisture stress, above-ground biomass and rooting characteristics. The overall goal of the study is to quantify the components of water balance, and identify water quality and water use implications of these cropping systems.Key Words

  8. Heavy Chronic Intermittent Ethanol Exposure Alters Small Noncoding RNAs in Mouse Sperm and Epididymosomes.

    PubMed

    Rompala, Gregory R; Mounier, Anais; Wolfe, Cody M; Lin, Qishan; Lefterov, Iliya; Homanics, Gregg E

    2018-01-01

    While the risks of maternal alcohol abuse during pregnancy are well-established, several preclinical studies suggest that chronic preconception alcohol consumption by either parent may also have significance consequences for offspring health and development. Notably, since isogenic male mice used in these studies are not involved in gestation or rearing of offspring, the cross-generational effects of paternal alcohol exposure suggest a germline-based epigenetic mechanism. Many recent studies have demonstrated that the effects of paternal environmental exposures such as stress or malnutrition can be transmitted to the next generation via alterations to small noncoding RNAs in sperm. Therefore, we used high throughput sequencing to examine the effect of preconception ethanol on small noncoding RNAs in sperm. We found that chronic intermittent ethanol exposure altered several small noncoding RNAs from three of the major small RNA classes in sperm, tRNA-derived small RNA (tDR), mitochondrial small RNA, and microRNA. Six of the ethanol-responsive small noncoding RNAs were evaluated with RT-qPCR on a separate cohort of mice and five of the six were confirmed to be altered by chronic ethanol exposure, supporting the validity of the sequencing results. In addition to altered sperm RNA abundance, chronic ethanol exposure affected post-transcriptional modifications to sperm small noncoding RNAs, increasing two nucleoside modifications previously identified in mitochondrial tRNA. Furthermore, we found that chronic ethanol reduced epididymal expression of a tRNA methyltransferase, Nsun2 , known to directly regulate tDR biogenesis. Finally, ethanol-responsive sperm tDR are similarly altered in extracellular vesicles of the epididymis (i.e., epididymosomes), supporting the hypothesis that alterations to sperm tDR emerge in the epididymis and that epididymosomes are the primary source of small noncoding RNAs in sperm. These results add chronic ethanol to the growing list of paternal exposures that can affect small noncoding RNA abundance and nucleoside modifications in sperm. As small noncoding RNAs in sperm have been shown to causally induce heritable phenotypes in offspring, additional research is warranted to understand the potential effects of ethanol-responsive sperm small noncoding RNAs on offspring health and development.

  9. Heavy Chronic Intermittent Ethanol Exposure Alters Small Noncoding RNAs in Mouse Sperm and Epididymosomes

    PubMed Central

    Rompala, Gregory R.; Mounier, Anais; Wolfe, Cody M.; Lin, Qishan; Lefterov, Iliya; Homanics, Gregg E.

    2018-01-01

    While the risks of maternal alcohol abuse during pregnancy are well-established, several preclinical studies suggest that chronic preconception alcohol consumption by either parent may also have significance consequences for offspring health and development. Notably, since isogenic male mice used in these studies are not involved in gestation or rearing of offspring, the cross-generational effects of paternal alcohol exposure suggest a germline-based epigenetic mechanism. Many recent studies have demonstrated that the effects of paternal environmental exposures such as stress or malnutrition can be transmitted to the next generation via alterations to small noncoding RNAs in sperm. Therefore, we used high throughput sequencing to examine the effect of preconception ethanol on small noncoding RNAs in sperm. We found that chronic intermittent ethanol exposure altered several small noncoding RNAs from three of the major small RNA classes in sperm, tRNA-derived small RNA (tDR), mitochondrial small RNA, and microRNA. Six of the ethanol-responsive small noncoding RNAs were evaluated with RT-qPCR on a separate cohort of mice and five of the six were confirmed to be altered by chronic ethanol exposure, supporting the validity of the sequencing results. In addition to altered sperm RNA abundance, chronic ethanol exposure affected post-transcriptional modifications to sperm small noncoding RNAs, increasing two nucleoside modifications previously identified in mitochondrial tRNA. Furthermore, we found that chronic ethanol reduced epididymal expression of a tRNA methyltransferase, Nsun2, known to directly regulate tDR biogenesis. Finally, ethanol-responsive sperm tDR are similarly altered in extracellular vesicles of the epididymis (i.e., epididymosomes), supporting the hypothesis that alterations to sperm tDR emerge in the epididymis and that epididymosomes are the primary source of small noncoding RNAs in sperm. These results add chronic ethanol to the growing list of paternal exposures that can affect small noncoding RNA abundance and nucleoside modifications in sperm. As small noncoding RNAs in sperm have been shown to causally induce heritable phenotypes in offspring, additional research is warranted to understand the potential effects of ethanol-responsive sperm small noncoding RNAs on offspring health and development. PMID:29472946

  10. Endoscopic endonasal dacryocystorhinostomy with ostial stent intubation following nasolacrimal duct stent incarceration.

    PubMed

    Wang, Xiaopeng; Bian, Yang; Yan, Wentao; Daniel, Pelaez; Tu, Yunhai; Wu, Wencan

    2015-01-01

    To study the feasibility of endoscopic endonasal dacryocystorhinostomy (EE-DCR) with novel lacrimal ostial stent (LOS) intubation for patients with chronic dacryocystitis with incarceration of a previously implanted nasolacrimal duct stent (NDS). According to surgical procedure, 166 patients (167 eyes) were divided into two groups: EE-DCR with LOS intubation was performed on 126 patients (127 eyes) in the EE-DCR group; while external dacryocystorhinostomy (E-DCR) with silicone tube intubation was performed on 40 patients (40 eyes) in the E-DCR group. The LOS or silicone tube was retained for 3-6 months. All patients were followed up for 12-36 months. Success rate of tear drainage reconstruction (TDR) and complications were retrospectively compared. Excluding patients with early detachment of the LOS or the silicone tube, or with incomplete follow-up period, 117 patients (117 eyes) in the EE-DCR group and 36 patients (36 eyes) in the E-DCR group were included. The mean surgical time was 45.8 ± 11.5 min in the EE-DCR group and 68.1 ± 23.8 min in the E-DCR group (p < 0.001). Intraoperatively, the lacrimal sac was observed to become very small and its walls were thin, hyperemic and fragile, firmly attaching to the NDS by fibrous bands in all eyes. Upon final review, success rate of TDR was 83.8% (98/117) in the EE-DCR group, while 58.3% (21/36) in the E-DCR group (p < 0.01). Failure of TDR due to ostial closure by excessive fibrosis occurred in 14 out of 19 patients in the EE-DCR group, significantly less than the 11 out of 15 patients with failed TDR in the E-DCR group (χ(2 )= 6.959, p < 0.01). No significant difference existed in failures due to granuloma occluding the ostium or common canaliculus obstruction. EE-DCR with LOS intubation may be an effective procedure to manage the special subgroup of patients with chronic dacryocystitis with incarcerations of a previously implanted NDS.

  11. A Concept for the Development of Spatially Resolved Measurements for Soil Moisture with TEM Waveguides

    NASA Astrophysics Data System (ADS)

    Lapteva, Yulia; Schmidt, Felix; Bumberger, Jan

    2014-05-01

    Soil water content plays a leading role in delimitating water and energy fluxes at the land surface and controlling groundwater recharging. The information about water content in the soil would be very useful in overcoming the challenge of managing water resources under conditions of increasing scarcity in Southern Europe and the Mediterranean region.For collecting data about the water content in soil, it is possible to use remote sensing and groundwater monitoring, built wireless sensor networks for water monitoring. Remote sensing provides a unique capability to get the information of soil moisture at global and regional scales. Wireless environmental sensor networks enable to connect local and regional-scale soil water content observations. There exist different ground based soil moisture measurement methods such as TDR, FDR, electromagnetic waves (EW), electrical and acoustic methods. Among these methods, the time domain reflectometry (TDR) is considered to be the most important and widely used electromagnetic approach. The special techniques for the reconstruction of the layered soil with TDR are based on differential equations in the time domain and numerical optimization algorithms. However, these techniques are time- consuming and suffering from some problems, like multiple reflections at the boundary surfaces. To overcome these limitations, frequency domain measurement (FDM) techniques could be used. With devices like vector network analyzers (VNA) the accuracy of the measurement itself and of the calibration can be improved. For field applicable methods the reflection coefficient is mathematically transformed in the time domain, which can be treated like TDR-data and the same information can be obtained. There are already existed some experiments using the frequency domain data directly as an input for inversion algorithms to find the spatial distribution of the soil parameters. The model that is used represents an exact solution of the Maxwell's equations. It describes the one-dimensional wave propagation in a multi-layered medium, assuming the wave to be transverse electromagnetic (TEM). In the particular case of transmission lines with perpendicularly arranged layer transitions this assumption is very close to reality. Such waveguides and their frequency domain measurements in layered media are promising concerning a development ways working with soil moisture detection.

  12. Development and Translation of a Tissue-Engineered Disc in a Preclinical Rodent Model

    DTIC Science & Technology

    2013-10-01

    authors Dong Hwa Kim, John T. Martin, Dawn M. Elliott, Lachlan J. Smith , and Robert L. Mauck...Replacement in a Small Animal Model with authors John T. Martin, Andrew H. Milby, Joseph A. Chiaro, Dong Hwa Kim, Nader M. Hebela, Lachlan J. Smith , Dawn... Smith , Dawn M. Elliott, and Robert L. Mauck is now in review. To carry out this study, radiopaque scaffolds were generated from a 14.3% w/v slurry

  13. Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator

    PubMed Central

    Moghadas, Parshia; Shepherd, Duncan ET; Hukins, David WL

    2015-01-01

    The Charité® lumbar intervertebral disc replacement was subjected to wear testing in an electro-mechanical spine simulator. Sinusoidally varying compression (0.6–2 kN, frequency 2 Hz), rotation (±2°, frequency 1 Hz), flexion–extension (6° to −3°, frequency 1 Hz) and lateral bending (±2°, frequency 1 Hz) were applied out of phase to specimens immersed in diluted calf serum at 37 °C. The mass of the ultra-high-molecular weight polyethylene component of the device was measured at intervals of 0.5, 1, 2, 3, 4 and 5 million cycles; its volume was also measured by micro-computed tomography. Total mass and volume losses were 60.3 ± 4.6 mg (mean ± standard deviation) and 64.6 ± 6.0 mm3. Corresponding wear rates were 12.0 ± 1.4 mg per million cycles and 12.8 ± 1.2 mm3 per million cycles; the rate of loss of volume corresponds to a mass loss of 11.9 ± 1.1 mg per million cycles, that is, the two sets of measurements of wear agree closely. Wear rates also agree closely with measurements made in another laboratory using the same protocol but using a conventional mechanical spine simulator. PMID:25834002

  14. Agricultural Geophysics

    USDA-ARS?s Scientific Manuscript database

    The four geophysical methods predominantly used for agricultural purposes are resistivity, electromagnetic induction, ground penetrating radar (GPR), and time domain reflectometry (TDR). Resistivity and electromagnetic induction methods are typically employed to map lateral variations of apparent so...

  15. Analysis of the spinal nerve roots in relation to the adjacent vertebral bodies with respect to a posterolateral vertebral body replacement procedure.

    PubMed

    Awwad, Waleed; Bourget-Murray, Jonathan; Zeiadin, Nadil; Mejia, Juan P; Steffen, Thomas; Algarni, Abdulrahman D; Alsaleh, Khalid; Ouellet, Jean; Weber, Michael; Jarzem, Peter F

    2017-01-01

    This study aims to improve the understanding of the anatomic variations along the thoracic and lumbar spine encountered during an all-posterior vertebrectomy, and reconstruction procedure. This information will help improve our understanding of human spine anatomy and will allow better planning for a vertebral body replacement (VBR) through either a transpedicular or costotransversectomy approach. The major challenge to a total posterior approach vertebrectomy and VBR in the thoracolumbar spine lies in the preservation of important neural structures. This was a retrospective analysis. Hundred normal magnetic resonance imaging (MRI) spinal studies (T1-L5) on sagittal T2-weighted MRI images were studied to quantify: (1) mid-sagittal vertebral body (VB) dimensions (anterior, midline, and posterior VB height), (2) midline VB and associated intervertebral discs height, (3) mean distance between adjacent spinal nerve roots (DNN) and mean distance between the inferior endplate of the superior vertebrae to its respective spinal nerve root (DNE), and (4) posterior approach expansion ratio (PAER). (1) The mean anterior VB height gradually increased craniocaudally from T1 to L5. The mean midline and posterior VB height showed a similar pattern up to L2. Mean posterior VB height was larger than the mean anterior VB height from T1 to L2, consistent with anterior wedging, and then measured less than the mean anterior VB height, indicating posterior wedging. (2) Midline VB and intervertebral disc height gradually increased from T1 to L4. (3) DNN and DNE were similar, whereby they gradually increased from T1 to L3. (5) Mean PAER varied between 1.69 (T12) and 2.27 (L5) depending on anatomic level. The dimensions of the thoracic and lumbar vertebrae and discs vary greatly. Thus, any attempt at carrying out a VBR from a posterior approach should take into account the specifications at each spinal level.

  16. Tracking and data relay satellite system configuration and tradeoff study. Volume 5: TDRS spacecraft design, part 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A dual spin stabilized TDR spacecraft design is presented for low data rate (LDR) and medium data rate (MDR) user spacecraft telecommunication relay service. The relay satellite provides command and data return channels for unmanned users together with duplex voice and data communication channels for manned user spacecraft. TDRS/ground links are in the Ku band. Command links are provided at UHF for LDR users and S band for MDR users. Voice communication channels are provided at UHF/VHF for LDR users and at S band for MDR users. The spacecraft is designed for launch on the Delta 2914 with system deployment planned for 1978. This volume contains a description of the overall TDR spacecraft configuration, a detailed description of the spacecraft subsystems, a reliability analysis, and a product effectiveness plan.

  17. KSC-07pd3642

    NASA Image and Video Library

    2007-12-14

    KENNEDY SPACE CENTER, FLA. -- In the cryogenic test bed facility at NASA's Kennedy Space Center, technicians monitor readings during a test exposing Time Domain Reflectometry, or TDR, instrumentation to "wet" super-cold temperatures for identifying the signature of a cryogenic environment and calibrating the TDR equipment. The equipment will be used at the launch pad to test a procedure identical to a tanking test on space shuttle Atlantis' external tank planned for Dec. 18. The shuttle's planned launches on Dec. 6 and Dec. 9 were postponed because of false readings from the part of the engine cut-off, or ECO, sensor system that monitors the liquid hydrogen section of the tank. The liftoff date from NASA's Kennedy Space Center, Florida, is now targeted for Jan. 10, depending on the resolution of the problem in the fuel sensor system. Photo credit: NASA/Kim Shiflett

  18. Dielectric relaxation measurement and analysis of restricted water structure in rice kernels

    NASA Astrophysics Data System (ADS)

    Yagihara, Shin; Oyama, Mikio; Inoue, Akio; Asano, Megumi; Sudo, Seiichi; Shinyashiki, Naoki

    2007-04-01

    Dielectric relaxation measurements were performed for rice kernels by time domain reflectometry (TDR) with flat-end coaxial electrodes. Difficulties in good contact between the surfaces of the electrodes and the kernels are eliminated by a TDR set-up with a sample holder for a kernel, and the water content could be evaluated from relaxation curves. Dielectric measurements were performed for rice kernels, rice flour and boiled rice with various water contents, and the water amount and dynamic behaviour of water molecules were explained from restricted dynamics of water molecules and also from the τ-β (relaxation time versus the relaxation-time distribution parameter of the Cole-Cole equation) diagram. In comparison with other aqueous systems, the dynamic structure of water in moist rice is more similar to aqueous dispersion systems than to aqueous solutions.

  19. [Application of time domain reflectometry for determination of wate content in Xiangsha Yangwei pills].

    PubMed

    Long, Feng-Lai; Sun, Xiao-Mei; Peng, Xiu-Juan; Liu, Peng; He, Fang-Hui

    2016-08-01

    Xiangsha Yangwei pill was selected as a model drug in this research, and time domain reflectometry (TDR) was used to determine the water content in the pill. The effects of five factors including the number of pill layers, pill packing density, atmospheric moisture, ambient temperature and the ratio of pill formula were investigated on water content. The results showed that the number of pill layers and ambient temperature had significant effects on water content of pills, while the pill packing density, atmospheric moisture and pill formula ratio had little effect on the determination of water content in pills. The reflection value was stable when 6 layers of pills were used. Under the condition of 25 ℃ and 45% relative humidity, the water content of pills ranged from 4.01% to 22.38%, showing good linear relationship between water content and reflection value, and the model equation was as follows: Y=0.279X-21.670 (R²=0.997 0). Verification experiment was used to explain the feasibility of this prediction model. The precision of the method complied with the methodology standard. It is concluded that TDR can be used in determination of water content in Xiangsha Yangwei pills. Additionally, TDR, as a new way to quickly and efficiently determine the water content, has a prospect application in the processing of traditional Chinese medicine pharmacy, especially for concentrated pill. Copyright© by the Chinese Pharmaceutical Association.

  20. Influence of Clay Content, Mineralogy and Fabric On Radar Frequency Response of Aquifer Materials

    NASA Astrophysics Data System (ADS)

    West, L. J.; Handley, K.

    High frequency electromagnetic methods such as ground penetrating radar (GPR) and time domain reflectometry (TDR) are widely employed to measure water saturation in the vadose zone and water filled porosity in the saturated zone. However, previous work has shown that radar frequency dielectric properties are strongly influenced by clay as well as by water content. They have also shown that that the dielectric response of clay minerals is strongly frequency dependent, and that even a small proportion of clay such as that present in many sandstone aquifers can have a large effect at typi- cal GPR frequencies (around 100MHz). Hence accurate water content/porosity deter- mination requires clay type and content to be taken into account. Reported here are dielectric measurements on clay-sand mixtures, aimed at investigating the influence of clay mineralogy, particle shape, and the geometrical arrangement of the mixture constituents on GPR and TDR response. Dielectric permittivity (at 50-1000MHz) was measured for mixtures of Ottawa Sand and various clay minerals or clay size quartz rock flour, using a specially constructed dielectric cell. Both homogeneous and layered mixtures were tested. The influence of pore water salinity, clay type, and particle arrangement on the dielectric response is interpreted in terms of dielectric dispersion mechanisms. The appropriateness of var- ious dielectric mixing rules such as the Complex Refractive Index Method (CRIM) for determination of water content or porosity from field GPR and TDR data are dis- cussed.

  1. Loss of notochordal cell phenotype in 3D-cell cultures: implications for disc physiology and disc repair.

    PubMed

    Omlor, G W; Nerlich, A G; Tirlapur, U K; Urban, J P; Guehring, T

    2014-12-01

    Embryonic notochordal disc nucleus cells (NC) have been identified to protect disc tissue against disc degeneration but in human beings NC phenotype gets lost with aging and the pathophysiological mechanisms are poorly understood. NC may stimulate other cells via soluble factors, and NC-conditioned medium can be used to stimulate matrix production of other disc cells and mesenchymal stem cells and thus may be of special interest for biological disc repair. As this stimulatory effect is associated with the NC phenotype, we investigated how cell morphology and gene-expression of the NC phenotype changes with time in 3D-cell culture. NC and inner annulus chondrocyte-like cells (CLC) from immature pigtails (freshly isolated cells/tissue, 3D-alginate beads, 3D-clusters) were cultured for up to 16 days under normoxia and hypoxia. Protein-expression was analysed by immunohistology and gene-expression analysis was carried out on freshly isolated cells and cultured cells. Cell morphology and proliferation were analysed by two-photon-laser-microscopy. Two-photon-laser-microscopy showed a homogenous and small CLC population in the inner annulus, which differed from the large vacuole-containing NC in the nucleus. Immunohistology found 93 % KRT8 positive cells in the nucleus and intracellular and pericellular Col2, IL6, and IL12 staining while CLC were KRT8 negative. Freshly isolated NC showed significantly higher KRT8 and CAIII but lower Col2 gene-expression than CLC. NC in 3D-cultures demonstrated significant size reduction and loss of vacuoles with culture time, all indicating a loss of the characteristic NC morphology. Hypoxia reduced the rate of decrease in NC size and vacuoles. Gene-expression of KRT8 and CAIII in NC fell significantly early in culture while Col2 did not decrease significantly within the culture period. In CLC, KRT8 and CAIII gene-expression was low and did not change noticeably in culture, whereas Col2 expression fell with time in culture. 3D-culture caused a rapid loss of NC phenotype towards a CLC phenotype with disappearance of vacuoles, reduced cell size, increased proliferation, and gene-expression changes. These findings may be related to NC nutritional demands and support the latest hypothesis of NC maturation into CLC opposing the idea that NC get lost in human discs by cell death or apoptosis to be replaced by CLC from the inner annulus.

  2. Injectible bodily prosthetics employing methacrylic copolymer gels

    DOEpatents

    Mallapragada, Surya K.; Anderson, Brian C.

    2007-02-27

    The present invention provides novel block copolymers as structural supplements for injectible bodily prosthetics employed in medical or cosmetic procedures. The invention also includes the use of such block copolymers as nucleus pulposus replacement materials for the treatment of degenerative disc disorders and spinal injuries. The copolymers are constructed by polymerization of a tertiary amine methacrylate with either a (poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) polymer, such as the commercially available Pluronic.RTM. polymers, or a poly(ethylene glycol) methyl ether polymer.

  3. Anterior surgical management of single-level cervical disc disease: a cost-effectiveness analysis.

    PubMed

    Lewis, Daniel J; Attiah, Mark A; Malhotra, Neil R; Burnett, Mark G; Stein, Sherman C

    2014-12-01

    Cost-effectiveness analysis with decision analysis and meta-analysis. To determine the relative cost-effectiveness of anterior cervical discectomy with fusion (with autograft, allograft, or spacers), anterior cervical discectomy without fusion (ACD), and cervical disc replacement (CDR) for the treatment of 1-level cervical disc disease. There is debate as to the optimal anterior surgical strategy to treat single-level cervical disc disease. Surgical strategies include 3 techniques of anterior cervical discectomy with fusion (autograft, allograft, or spacer-assisted fusion), ACD, and CDR. Several controlled trials have compared these treatments but have yielded mixed results. Decision analysis provides a structure for making a quantitative comparison of the costs and outcomes of each treatment. A literature search was performed and yielded 156 case series that fulfilled our search criteria describing nearly 17,000 cases. Data were abstracted from these publications and pooled meta-analytically to estimate the incidence of various outcomes, including index-level and adjacent-level reoperation. A decision analytic model calculated the expected costs in US dollars and outcomes in quality-adjusted life years for a typical adult patient with 1-level cervical radiculopathy subjected to each of the 5 approaches. At 5 years postoperatively, patients who had undergone ACD alone had significantly (P < 0.001) more quality-adjusted life years (4.885 ± 0.041) than those receiving other treatments. Patients with ACD also exhibited highly significant (P < 0.001) differences in costs, incurring the lowest societal costs ($16,558 ± $539). Follow-up data were inadequate for comparison beyond 5 years. The results of our decision analytic model indicate advantages for ACD, both in effectiveness and costs, over other strategies. Thus, ACD is a cost-effective alternative to anterior cervical discectomy with fusion and CDR in patients with single-level cervical disc disease. Definitive conclusions about degenerative changes after ACD and adjacent-level disease after CDR await longer follow-up. 4.

  4. Storing, Browsing, Querying, and Sharing Data: the THREDDS Data Repository (TDR)

    NASA Astrophysics Data System (ADS)

    Wilson, A.; Lindholm, D.; Baltzer, T.

    2005-12-01

    The Unidata Internet Data Distribution (IDD) network delivers gigabytes of data per day in near real time to sites across the U.S. and beyond. The THREDDS Data Server (TDS) supports public browsing of metadata and data access via OPeNDAP enabled URLs for datasets such as these. With such large quantities of data, sites generally employ a simple data management policy, keeping the data for a relatively short term on the order of hours to perhaps a week or two. In order to save interesting data in longer term storage and make it available for sharing, a user must move the data herself. In this case the user is responsible for determining where space is available, executing the data movement, generating any desired metadata, and setting access control to enable sharing. This task sequence is generally based on execution of a sequence of low level operating system specific commands with significant user involvement. The LEAD (Linked Environments for Atmospheric Discovery) project is building a cyberinfrastructure to support research and education in mesoscale meteorology. LEAD orchestrations require large, robust, and reliable storage with speedy access to stage data and store both intermediate and final results. These requirements suggest storage solutions that involve distributed storage, replication, and interfacing to archival storage systems such as mass storage systems and tape or removable disks. LEAD requirements also include metadata generation and access in order to support querying. In support of both THREDDS and LEAD requirements, Unidata is designing and prototyping the THREDDS Data Repository (TDR), a framework for a modular data repository to support distributed data storage and retrieval using a variety of back end storage media and interchangeable software components. The TDR interface will provide high level abstractions for long term storage, controlled, fast and reliable access, and data movement capabilities via a variety of technologies such as OPeNDAP and gridftp. The modular structure will allow substitution of software components so that both simple and complex storage media can be integrated into the repository. It will also allow integration of different varieties of supporting software. For example, if replication is desired, replica management could be handled via a simple hash table or a complex solution such as Replica Locater Service (RLS). In order to ensure that metadata is available for all the data in the repository, the TDR will also generate THREDDS metadata when necessary. Users will be able to establish levels of access control to their metadata and data. Coupled with a THREDDS Data Server, both browsing via THREDDS catalogs and querying capabilities will be supported. This presentation will describe the motivating factors, current status, and future plans of the TDR. References: IDD: http://www.unidata.ucar.edu/content/software/idd/index.html THREDDS: http://www.unidata.ucar.edu/content/projects/THREDDS/tech/server/ServerStatus.html LEAD: http://lead.ou.edu/ RLS: http://www.isi.edu/~annc/papers/chervenakRLSjournal05.pdf

  5. Determining soil volumetric moisture content using time domain reflectometry

    DOT National Transportation Integrated Search

    1998-02-01

    Time domain reflectometry (TDR) is a technique used to measure indirectly the in situ volumetric moisture content of soil. Current research provides a variety of prediction equations that estimate the volumetric moisture content using the dielectric ...

  6. Inclinometer--time-domain reflectometry comparative study : research implementation plan.

    DOT National Transportation Integrated Search

    2005-10-01

    ODOT currently uses slope indicator probing to analyze subsurface conditions at roadway landslide : locations. However, the current method is subject to several limitations, and time domain reflectometry : (TDR) has been proposed as an alternative to...

  7. OBSERVATIONS ON THE UPTAKE OF TRITIATED THYMIDINE IN THE PRONUCLEI OF FERTILIZED SAND DOLLAR EMBRYOS.

    PubMed

    Simmel, E B; Karnofsky, D A

    1961-05-01

    Following fertilization of the egg of the sand dollar Echinarachnius parma, tritiated thymidine (H(3)TDR) was taken up independently by the male and female pronuclei beginning within about 15 to 20 minutes, and the labeled pronuclei fused at about 30 to 40 minutes. At cleavage 90 minutes later the labeled nuclear material was distributed to both daughter cells. Unfertilized eggs and sperm exposed to H(3)TDR did not show nuclear localization of thymidine. DNA replication, thus, is initiated in the haploid pronuclei shortly after fertilization and prior to fusion. The major portion of DNA synthesis, as evidenced by thymidine uptake, appears to be during a 20 to 30 minute period after fertilization. Fertilization is associated with the activation of a mechanism which initiates early and independent replication of DNA in both the male and female pronuclei.

  8. OBSERVATIONS ON THE UPTAKE OF TRITIATED THYMIDINE IN THE PRONUCLEI OF FERTILIZED SAND DOLLAR EMBRYOS

    PubMed Central

    Simmel, Eva B.; Karnofsky, David A.

    1961-01-01

    Following fertilization of the egg of the sand dollar Echinarachnius parma, tritiated thymidine (H3TDR) was taken up independently by the male and female pronuclei beginning within about 15 to 20 minutes, and the labeled pronuclei fused at about 30 to 40 minutes. At cleavage 90 minutes later the labeled nuclear material was distributed to both daughter cells. Unfertilized eggs and sperm exposed to H3TDR did not show nuclear localization of thymidine. DNA replication, thus, is initiated in the haploid pronuclei shortly after fertilization and prior to fusion. The major portion of DNA synthesis, as evidenced by thymidine uptake, appears to be during a 20 to 30 minute period after fertilization. Fertilization is associated with the activation of a mechanism which initiates early and independent replication of DNA in both the male and female pronuclei. PMID:19866590

  9. Cancer cells recovering from damage exhibit mitochondrial restructuring and increased aerobic glycolysis.

    PubMed

    Akakura, Shin; Ostrakhovitch, Elena; Sanokawa-Akakura, Reiko; Tabibzadeh, Siamak

    2014-06-13

    Instead of relying on mitochondrial oxidative phosphorylation, most cancer cells rely heavily on aerobic glycolysis, a phenomenon termed as "the Warburg effect". We considered that this effect is a direct consequence of damage which persists in cancer cells that recover from damage. To this end, we studied glycolysis and rate of cell proliferation in cancer cells that recovered from severe damage. We show that in vitro Damage-Recovered (DR) cells exhibit mitochondrial structural remodeling, display Warburg effect, and show increased in vitro and in vivo proliferation and tolerance to damage. To test whether cancer cells derived from tumor microenvironment can show similar properties, we isolated Damage-Recovered (T(DR)) cells from tumors. We demonstrate that T(DR) cells also show increased aerobic glycolysis and a high proliferation rate. These findings show that Warburg effect and its consequences are induced in cancer cells that survive severe damage. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Reduced DNA repair in mouse satellite DNA after treatment with methylmethanesulfonate, and N-methyl-N-nitrosourea.

    PubMed Central

    Bodell, W J; Banerjee, M R

    1976-01-01

    We have measured DNA repair in mouse satellite and main band DNA as resolved by Ag+-Cs2SO4 centrifugation in response to treatment with the alkylating agents, methyl methanesulfonate, and N-methyl-N-nitrosourea. We find that there is a statistically significant lower incorporation of 3H-Tdr into the satellite DNA as compared to the main band at varying periods after treatment with the alkylating agents. This suggests a reduced repair activity in the satellite DNA. We have measured the extent of binding of 14C-methyl methanesulfonate to the satellite, and main band DNA, and no difference in binding was observed, indicating that the reduced repair activity of satellite DNA is not due to a difference in binding of alkylating agents. We believe that the reduced incorporation of 3H-Tdr into satellite DNA may be due to its location in the condensed chromatin fraction. PMID:184436

  11. Temporomandibular Joint Disorders: A Review of Etiology, Clinical Management, and Tissue Engineering Strategies

    PubMed Central

    Murphy, Meghan K.; MacBarb, Regina F.; Wong, Mark E.; Athanasiou, Kyriacos A.

    2015-01-01

    Epidemiology reports state temporomandibular joint disorders (TMD) affect up to 25% of the population, yet their etiology and progression are poorly understood. As a result, treatment options are limited and fail to meet the long-term demands of the relatively young patient population. TMD are a class of degenerative musculoskeletal conditions associated with morphological and functional deformities. In up to 70% of cases, TMD are accompanied by malpositioning of the TMJ disc, termed “internal derangement.” Though onset is not well characterized, correlations between internal derangement and osteoarthritic change have been identified. Due to the complex and unique nature of each TMD case, diagnosis requires patient-specific analysis accompanied by various diagnostic modalities. Likewise, treatment requires customized plans to address the specific characteristics of each patient’s disease. In the mechanically demanding and biochemically active environment of the TMJ, therapeutic approaches capable of restoring joint functionality while responding to changes in the joint have become a necessity. Capable of integration and adaptation in the TMJ, one such approach, tissue engineering, carries significant potential in the development of repair and replacement tissues. The following review presents a synopsis of etiology, current treatment methods, and the future of tissue engineering for repairing and/or replacing diseased joint components, specifically the mandibular condyle and TMJ disc. Preceding the current trends in tissue engineering is an analysis of native tissue characterization, toward identifying tissue engineering objectives and validation metrics for restoring healthy and functional structures of the TMJ. PMID:24278954

  12. Cervical anterior hybrid technique with bi-level Bryan artificial disc replacement and adjacent segment fusion for cervical myelopathy over three consecutive segments.

    PubMed

    Chen, Jiang; Xu, Lin; Jia, Yu-Song; Sun, Qi; Li, Jin-Yu; Zheng, Chen-Ying; Bai, Chun-Xiao; Yu, Qin-Sheng

    2016-05-01

    This study aimed to assess the preliminary clinical efficacy and feasibility of the hybrid technique for multilevel cervical myelopathy. Considering the many shortcomings of traditional treatment methods for multilevel cervical degenerative myelopathy, hybrid surgery (bi-level Bryan artificial disc [Medtronic Sofamor Danek, Memphis, TN, USA] replacement and anterior cervical discectomy and fusion) should be considered. Between March 2006 and November 2012, 108 patients (68 men and 40 women, average age 45years) underwent hybrid surgery. Based on the Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), and Odom's criteria, the clinical symptoms and neurological function before and after surgery were evaluated. Mean surgery duration was 90minutes, with average blood loss of 30mL. Mean follow-up duration was 36months. At the final follow-up, the mean JOA (± standard deviation) scores were significantly higher compared with preoperative values (15.08±1.47 versus 9.18±1.22; P<0.01); meanwhile, NDI values were markedly decreased (12.32±1.03 versus 42.68±1.83; P<0.01). Using Odom's criteria, the clinical outcomes were rated as excellent (76 patients), good (22 patients), fair (six patients), and poor (four patients). These findings indicate that the hybrid method provides an effective treatment for cervical myelopathy over three consecutive segments, ensuring a good clinical outcome. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Temporomandibular disorders: a review of etiology, clinical management, and tissue engineering strategies.

    PubMed

    Murphy, Meghan K; MacBarb, Regina F; Wong, Mark E; Athanasiou, Kyriacos A

    2013-01-01

    Temporomandibular disorders (TMD) are a class of degenerative musculoskeletal conditions associated with morphologic and functional deformities that affect up to 25% of the population, but their etiology and progression are poorly understood and, as a result, treatment options are limited. In up to 70% of cases, TMD are accompanied by malpositioning of the temporomandibular joint (TMJ) disc, termed "internal derangement." Although the onset is not well characterized, correlations between internal derangement and osteoarthritic change have been identified. Because of the complex and unique nature of each TMD case, diagnosis requires patient-specific analysis accompanied by various diagnostic modalities. Likewise, treatment requires customized plans to address the specific characteristics of each patient's disease. In the mechanically demanding and biochemically active environment of the TMJ, therapeutic approaches that can restore joint functionality while responding to changes in the joint have become a necessity. One such approach, tissue engineering, which may be capable of integration and adaptation in the TMJ, carries significant potential for the development of repair and replacement tissues. The following review presents a synopsis of etiology, current treatment methods, and the future of tissue engineering for repairing and/or replacing diseased joint components, specifically the mandibular condyle and TMJ disc. An analysis of native tissue characterization to assist clinicians in identifying tissue engineering objectives and validation metrics for restoring healthy and functional structures of the TMJ is followed by a discussion of current trends in tissue engineering.

  14. Performance of the STAR Event Plane Detector

    NASA Astrophysics Data System (ADS)

    Ewigleben, Justin; Justin Ewigleben Collaboration

    2017-09-01

    The Beam Energy Scan (BES) program at the Relativistic Heavy-Ion Collider has shown hints of a critical point and first order phase transition at the BES energies. Key measurements for locating the critical point and determining the first order phase transition are limited by poor event plane resolution, limited statistics and a TPC-only centrality determination. A new event plane and collision centrality detector (EPD) is planned to replace the existing detector, the Beam-Beam Counter (BBC), with higher granularity and acceptance. The design of the EPD consists of two scintillator discs at z = +/- 3.75m from the center of STAR, covering 2.2 < η < 5.1. One quarter of a single disc was installed in STAR for the 2017 run for commissioning. In this talk we will discuss the detector performance during this commissioning run in both proton-proton collisions at √{ s = 510 } GeV and Au-Au collisions at √{sNN = 54.4 } GeV. NSF Grant 1614474.

  15. Mapping patterns of soil properties and soil moisture using electromagnetic induction to investigate the impact of land use changes on soil processes

    NASA Astrophysics Data System (ADS)

    Robinet, Jérémy; von Hebel, Christian; van der Kruk, Jan; Govers, Gerard; Vanderborght, Jan

    2016-04-01

    As highlighted by many authors, classical or geophysical techniques for measuring soil moisture such as destructive soil sampling, neutron probes or Time Domain Reflectometry (TDR) have some major drawbacks. Among other things, they provide point scale information, are often intrusive and time-consuming. ElectroMagnetic Induction (EMI) instruments are often cited as a promising alternative hydrogeophysical methods providing more efficiently soil moisture measurements ranging from hillslope to catchment scale. The overall objective of our research project is to investigate whether a combination of geophysical techniques at various scales can be used to study the impact of land use change on temporal and spatial variations of soil moisture and soil properties. In our work, apparent electrical conductivity (ECa) patterns are obtained with an EM multiconfiguration system. Depth profiles of ECa were subsequently inferred through a calibration-inversion procedure based on TDR data. The obtained spatial patterns of these profiles were linked to soil profile and soil water content distributions. Two catchments with contrasting land use (agriculture vs. natural forest) were selected in a subtropical region in the south of Brazil. On selected slopes within the catchments, combined EMI and TDR measurements were carried out simultaneously, under different atmospheric and soil moisture conditions. Ground-truth data for soil properties were obtained through soil sampling and auger profiles. The comparison of these data provided information about the potential of the EMI technique to deliver qualitative and quantitative information about the variability of soil moisture and soil properties.

  16. Effects of 5-Fluorodeoxyuridine and Related Halogenated Pyrimidines on the Sand-Dollar Embryo

    PubMed Central

    Karnofsky, David A.; Basch, Ross S.

    1960-01-01

    The embryo of the sand-dollar (Echinarachnius parma) was exposed to various concentrations of fluorinated pyrimidines immediately after fertilization. FUDR (5-fluorodeoxyuridine) was most active, and a concentration of 2 to 4 mγ/10 cc. (0.8 to 1.6 x 10-6 m.eq./liter) blocked development at the early blastula stage. Larger doses interrupted development at the same stage. This effect was prevented by thymidine (TDR) and thymine (T); and these pyrimidines protected against many times the minimal lethal concentration of FUDR. TDR was active as a protective agent if added just before early blastula formation. The other fluorinated pyrimidines, 5-fluorouracil (FU), 5-fluorouridine (FUR), 5-fluorocytidine (FCR), 5-fluorodeoxycytidine (FCDR), and 5-fluoroorotic acid (FO), were also studied. These drugs produced effects on embryonic development similar to those seen with FUDR. The effective concentrations, however, varied greatly. T and TDR provided protection against these drugs, but in most cases they were not so effective as against FUDR. 5-Bromodeoxyurdine (BrUDR), beginning at the early blastula stage, caused a random pattern of embryonic death up to the pluteus stage. This drug has been shown to be incorporated into bacterial DNA. BrUDR protected embryos against the early lethal effects of FUDR presumably acting as a thymidine substitute, but the embryos died subsequently in a pattern similar to that seen with BrUDR alone. FUDR and BrUDR appear to inhibit the formation and alter the structure of DNA, respectively, distinctive effects whch may provide a means for studying the role of DNA in embryonic development. PMID:14404541

  17. Effects of 5-fluorodeoxyuridine and related halogenated pyrimidines on the sand-dollar embryo.

    PubMed

    KARNOFSKY, D A; BASCH, R S

    1960-02-01

    The embryo of the sand-dollar (Echinarachnius parma) was exposed to various concentrations of fluorinated pyrimidines immediately after fertilization. FUDR (5-fluorodeoxyuridine) was most active, and a concentration of 2 to 4 mgamma/10 cc. (0.8 to 1.6 x 10(-6) m.eq./liter) blocked development at the early blastula stage. Larger doses interrupted development at the same stage. This effect was prevented by thymidine (TDR) and thymine (T); and these pyrimidines protected against many times the minimal lethal concentration of FUDR. TDR was active as a protective agent if added just before early blastula formation. The other fluorinated pyrimidines, 5-fluorouracil (FU), 5-fluorouridine (FUR), 5-fluorocytidine (FCR), 5-fluorodeoxycytidine (FCDR), and 5-fluoroorotic acid (FO), were also studied. These drugs produced effects on embryonic development similar to those seen with FUDR. The effective concentrations, however, varied greatly. T and TDR provided protection against these drugs, but in most cases they were not so effective as against FUDR. 5-Bromodeoxyurdine (BrUDR), beginning at the early blastula stage, caused a random pattern of embryonic death up to the pluteus stage. This drug has been shown to be incorporated into bacterial DNA. BrUDR protected embryos against the early lethal effects of FUDR presumably acting as a thymidine substitute, but the embryos died subsequently in a pattern similar to that seen with BrUDR alone. FUDR and BrUDR appear to inhibit the formation and alter the structure of DNA, respectively, distinctive effects whch may provide a means for studying the role of DNA in embryonic development.

  18. PubMed Central

    Russo, Vincenzo; Papa, Andrea Antonio; Rago, Anna; D'Ambrosio, Paola; Cimmino, Giovanni; Palladino, Alberto; Nigro, Gerardo

    2016-01-01

    Sudden cardiac death in myotonic dystrophy type I (DM1) patients can be attributed to atrioventricular blocks as far as to the development of life-threatening arrhythmias which occur even in hearts with normal left ventricular systolic and diastolic function. Heterogeneity of ventricular repolarization is considered to provide an electrophysiological substrate for malignant arrhythmias. QTc dispersion (QTc-D), JTc dispersion (JTc-D) and transmural dispersion of repolarization (TDR) could reflect the physiological variability of regional and transmural ventricular repolarization. Aim of the present study was to investigate the heterogeneity of ventricular repolarization in patients with DM1 and preserved diastolic and systolic cardiac function. The study enrolled 50 DM1 patients (mean age 44 ± 5 years; M:F: 29:21) with preserved systolic and diastolic function of left ventricle among 247 DM1 patients followed at Cardiomyology and Medical Genetics of Second University of Naples, and 50 sexand age-matched healthy controls. The electrocardiographic parameters investigated were the following: Heart Rate, QRS duration, maximum and minimum QT and JT intervals, QTc- D, JTc-D and TDR. Compared to the controls, the DM1 group presented increased values of QTc-D (86.7 ± 40.1 vs 52.3 ± 11.9 ms; p = 0.03), JTc-D (78.6 ± 31.3 vs 61.3 ± 10.2 ms; p = 0.001) and TDR (101.6 ± 18.06 vs 90.1 ± 14.3 ms; p = 0.004) suggesting a significant increase in regional and transmural heterogeneity of the ventricular repolarization in these patients, despite a preserved systolic and diastolic cardiac function. PMID:28344440

  19. Identification of potentially cytotoxic lesions induced by UVA photoactivation of DNA 4-thiothymidine in human cells

    PubMed Central

    Reelfs, Olivier; Macpherson, Peter; Ren, Xiaolin; Xu, Yao-Zhong; Karran, Peter; Young, Antony R.

    2011-01-01

    Photochemotherapy—in which a photosensitizing drug is combined with ultraviolet or visible radiation—has proven therapeutic effectiveness. Existing approaches have drawbacks, however, and there is a clinical need to develop alternatives offering improved target cell selectivity. DNA substitution by 4-thiothymidine (S4TdR) sensitizes cells to killing by ultraviolet A (UVA) radiation. Here, we demonstrate that UVA photoactivation of DNA S4TdR does not generate reactive oxygen or cause direct DNA breakage and is only minimally mutagenic. In an organotypic human skin model, UVA penetration is sufficiently robust to kill S4TdR-photosensitized epidermal cells. We have investigated the DNA lesions responsible for toxicity. Although thymidine is the predominant UVA photoproduct of S4TdR in dilute solution, more complex lesions are formed when S4TdR-containing oligonucleotides are irradiated. One of these, a thietane/S5-(6-4)T:T, is structurally related to the (6-4) pyrimidine:pyrimidone [(6-4) Py:Py] photoproducts induced by UVB/C radiation. These lesions are detectable in DNA from S4TdR/UVA-treated cells and are excised from DNA more efficiently by keratinocytes than by leukaemia cells. UVA irradiation also induces DNA interstrand crosslinking of S4TdR-containing duplex oligonucleotides. Cells defective in repairing (6-4) Py:Py DNA adducts or processing DNA crosslinks are extremely sensitive to S4TdR/UVA indicating that these lesions contribute significantly to S4TdR/UVA cytotoxicity. PMID:21890905

  20. Field evaluations of "ShapeAccelArray" in-place MEMS inclinometer strings for subsurface deformation monitoring.

    DOT National Transportation Integrated Search

    2012-03-01

    Continuous monitoring of subsurface ground movements is accomplished with in-place instruments utilizing automated data acquisition methods. These typically include TDR (Time Domain Reflectometry) or assemblies of several servo-accelerometer-based, e...

  1. Determination of medium electrical properties through full-wave modelling of frequency domain reflectrometry data

    NASA Astrophysics Data System (ADS)

    André, Frédéric; Lambot, Sébastien

    2015-04-01

    Accurate knowledge of the shallow soil properties is of prime importance in agricultural, hydrological and environmental engineering. During the last decade, numerous geophysical techniques, either invasive or resorting to proximal or remote sensing, have been developed and applied for quantitative characterization of soil properties. Amongst them, time domain reflectrometry (TDR) and frequency domain reflectometry (FDR) are recognized as standard techniques for the determination of soil dielectric permittivity and electrical conductivity, based on the reflected electromagnetic waves from a probe inserted into the soil. TDR data were first commonly analyzed in the time domain using methods considering only a part of the waveform information. Later, advancements have led to the possibility of analyzing the TDR signal through full-wave inverse modeling either in the time or the frequency domains. A major advantage of FDR compared to TDR is the possibility to increase the bandwidth, thereby increasing the information content of the data and providing more detailed characterization of the medium. Amongst the recent works in this field, Minet et al. (2010) developed a modeling procedure for processing FDR data based on an exact solution of Maxwell's equations for wave propagation in one-dimensional multilayered media. In this approach, the probe head is decoupled from the medium and is fully described by characteristic transfer functions. The authors successfully validated the method for homogeneous sand subject to a range of water contents. In the present study, we further validated the modelling approach using reference liquids with well-characterized frequency-dependent electrical properties. In addition, the FDR model was coupled with a dielectric mixing model to investigate the ability of retrieving water content, pore water electrical conductivity and sand porosity from inversion of FDR data acquired in sand subject to different water content levels. Finally, the possibility of reconstructing the vertical profile of the properties by inversion of FDR data collected during progressive insertion of the probe into a vertically heterogeneous medium was also investigated. Index Terms: Frequency domain reflectrometry (FDR), frequency dependence, dielectric permittivity, electrical conductivity Reference: Minet J., Lambot S., Delaide G., Huisman J.A., Vereecken H., Vanclooster M., 2010. A generalized frequency domain reflectometry modeling technique for soil electrical properties determination. Vadose Zone Journal, 9: 1063-1072.

  2. Transmitted antiretroviral drug resistance in treatment naïve HIV-infected persons in London in 2011 to 2013.

    PubMed

    McFaul, Katie; Lim, Charlotte; Jones, Rachael; Asboe, David; Pozniak, Anton; Sonecha, Sonali; Boffito, Marta; Nwokolo, Nneka

    2014-01-01

    Previously published UK data on HIV transmitted drug resistance (TDR) shows that it ranges between 3 and 9.4% [1,2]. However, there are no recent data from populations where HIV transmission rates are increasing. The aim of this study was to assess the prevalence of TDR in untreated HIV-infected individuals attending three HIV specialist clinics under the HIV Directorate, Chelsea and Westminster Hospital and based throughout London - the Kobler Clinic, 56 Dean Street and West London Centre for Sexual Health. We included all patients with a HIV diagnosis, no history of antiretroviral therapy (ART) intake, attending one of the three clinics (Kobler (K), 56 Dean Street (DS) and West London (WL)), between 2011 and 2013 who started antiretrovirals. Reverse transcriptase (RT) and protease region sequencing was performed using Vircotype virtual phenotype resistance analysis. Drug resistance mutations were identified according to Stanford University HIV Drug Resistance Database (http://hivdb.stanford.edu/). Among 1705 HIV-1-infected patients enrolled in the study, 1252 were males (919 were MSM), 107 were females and 346 had no gender recorded. Ethnicity was 51.1% white British/Irish/other, 6.1% African, 2.1% Caribbean, 2.8% Asian, 1.3% Indian/Pakistani/Bangladeshi, 4.2%, other, 3.2% not stated, and 29.2% unknown. 547 were from K (84.3% males, 48.3% MSM), 826 were from DS (84.3% males, 71.9% MSM), and 109 from WL (87.2% males, 56.0% MSM), 223 from other sites not specified. 77.5% (1321 of 1705) of patients had baseline viral resistance testing performed. Prevalence of primary resistance in those with a baseline viral resistance test was 13.5% overall: 19.3% in K, 14.9% in DS, and 14.7% in WL. The most common mutations detected were: NRTI: 184V, 215F, 41L; NNRTI 103N, 179D, 90I; PI 90M, 46I, and 82A. Among patients who tested with TDR, 79.1% had one single mutation, 18.7% and 2.2% exhibited dual or triple class-resistant viruses, respectively. This study across a large HIV Medicine Directorate reported an overall TDR prevalence which is higher than that previously published and with significant rates of NNRTI resistance at baseline.

  3. A radiopaque electrospun scaffold for engineering fibrous musculoskeletal tissues: Scaffold characterization and in vivo applications.

    PubMed

    Martin, John T; Milby, Andrew H; Ikuta, Kensuke; Poudel, Subash; Pfeifer, Christian G; Elliott, Dawn M; Smith, Harvey E; Mauck, Robert L

    2015-10-01

    Tissue engineering strategies have emerged in response to the growing prevalence of chronic musculoskeletal conditions, with many of these regenerative methods currently being evaluated in translational animal models. Engineered replacements for fibrous tissues such as the meniscus, annulus fibrosus, tendons, and ligaments are subjected to challenging physiologic loads, and are difficult to track in vivo using standard techniques. The diagnosis and treatment of musculoskeletal conditions depends heavily on radiographic assessment, and a number of currently available implants utilize radiopaque markers to facilitate in vivo imaging. In this study, we developed a nanofibrous scaffold in which individual fibers included radiopaque nanoparticles. Inclusion of radiopaque particles increased the tensile modulus of the scaffold and imparted radiation attenuation within the range of cortical bone. When scaffolds were seeded with bovine mesenchymal stem cells in vitro, there was no change in cell proliferation and no evidence of promiscuous conversion to an osteogenic phenotype. Scaffolds were implanted ex vivo in a model of a meniscal tear in a bovine joint and in vivo in a model of total disc replacement in the rat coccygeal spine (tail), and were visualized via fluoroscopy and microcomputed tomography. In the disc replacement model, histological analysis at 4 weeks showed that the scaffold was biocompatible and supported the deposition of fibrous tissue in vivo. Nanofibrous scaffolds that include radiopaque nanoparticles provide a biocompatible template with sufficient radiopacity for in vivo visualization in both small and large animal models. This radiopacity may facilitate image-guided implantation and non-invasive long-term evaluation of scaffold location and performance. The healing capacity of fibrous musculoskeletal tissues is limited, and injury or degeneration of these tissues compromises the standard of living of millions in the US. Tissue engineering repair strategies for the intervertebral disc, meniscus, tendon and ligament have progressed from in vitro to in vivo evaluation using a variety of animal models, and the clinical application of these technologies is imminent. The composition of most scaffold materials however does not allow for visualization by methods available to clinicians (e.g., radiography), and thus it is not possible to assess their performance in situ. In this work, we describe a radiopaque nanofibrous scaffold that can be visualized radiographically in both small and large animal models and serve as a framework for the development of an engineered fibrous tissue. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. Effects of radial compression on a novel simulated intervertebral disc-like assembly using bone marrow-derived mesenchymal stem cell cell-sheets for annulus fibrosus regeneration.

    PubMed

    See, Eugene Yong-Shun; Toh, Siew Lok; Goh, James Cho-Hong

    2011-10-01

    The aim of this study was to develop a tissue engineering approach in regenerating the annulus fibrosus (AF) as part of an overall strategy to produce a tissue-engineered intervertebral disc (IVD) replacement. To determine whether a rehabilitative simulation regime on bone marrow–derived mesenchymal stem cell cell-sheet is able to aid the regeneration of the AF. No previous study has used bone marrow–derived mesenchymal stem cell cell-sheets simulated by a rehabilitative regime to regenerate the AF. The approach was to use bone marrow–derived stem cells to form cell-sheets and incorporating them onto silk scaffolds to simulate the native lamellae of the AF. The in vitro experimental model used to study the efficacy of such a system was made up of the tissue engineering AF construct wrapped around a silicone disc to form a simulated IVD-like assembly. The assembly was cultured within a custom-designed bioreactor that provided a compressive mechanical stimulation onto the silicone disc. The silicone nucleus pulposus would bulge radially and compress the simulated AF to mimic the physiological conditions. The simulated IVD-like assembly was compressed using a rehabilitative regime that lasted for 4 weeks at 0.25 Hz, for 15 minutes each day. With the rehabilitative regime, the cell-sheets remained viable but showed a decrease in cell numbers and viability. Gene expression analysis showed significant upregulation of IVD-related genes and there was an increased ratio of collagen type II to collagen type I found within the extracellular matrix. The results suggested that a rehabilitative regime caused extensive remodeling to take place within the simulated IVD-like assembly, producing extracellular matrix similar to that found in the inner AF.

  5. Biomechanical changes of the lumbar segment after total disc replacement : charite(r), prodisc(r) and maverick(r) using finite element model study.

    PubMed

    Kim, Ki-Tack; Lee, Sang-Hun; Suk, Kyung-Soo; Lee, Jung-Hee; Jeong, Bi-O

    2010-06-01

    The purpose of this study was to analyze the biomechanical effects of three different constrained types of an artificial disc on the implanted and adjacent segments in the lumbar spine using a finite element model (FEM). The created intact model was validated by comparing the flexion-extension response without pre-load with the corresponding results obtained from the published experimental studies. The validated intact lumbar model was tested after implantation of three artificial discs at L4-5. Each implanted model was subjected to a combination of 400 N follower load and 5 Nm of flexion/extension moments. ABAQUS version 6.5 (ABAQUS Inc., Providence, RI, USA) and FEMAP version 8.20 (Electronic Data Systems Corp., Plano, TX, USA) were used for meshing and analysis of geometry of the intact and implanted models. Under the flexion load, the intersegmental rotation angles of all the implanted models were similar to that of the intact model, but under the extension load, the values were greater than that of the intact model. The facet contact loads of three implanted models were greater than the loads observed with the intact model. Under the flexion load, three types of the implanted model at the L4-5 level showed the intersegmental rotation angle similar to the one measured with the intact model. Under the extension load, all of the artificial disc implanted models demonstrated an increased extension rotational angle at the operated level (L4-5), resulting in an increase under the facet contact load when compared with the adjacent segments. The increased facet load may lead to facet degeneration.

  6. Time-domain reflectometry of water content in portland cement concrete

    DOT National Transportation Integrated Search

    1997-11-01

    Time-domain reflectometry is useful for measuring the moisture content of solids. However, little information exists on its use with portland cement concrete. By monitoring the response from TDR sensors embedded in concrete as the concrete dried, the...

  7. Total prosthetic replacement of atrioventricular valves in the dog

    PubMed Central

    Den Otter, G.

    1968-01-01

    The free-floating cone and cage valve, described in a previous study as being successful as a substitute for the right atrioventricular valve, does not perform well when it is inserted in the mitral ostium. A tilting cone or disc was constructed and tested in a series of 15 dogs. This prosthesis gave excellent results in 12 animals. The reasons for its failure in the remaining three is discussed. The prosthesis presented has advantages over any ball and cage valve, mainly because of its smaller volume. Images PMID:5654076

  8. Clinical Evaluation and Magnetic Resonance Imaging Assessment of Intradiscal Methylene Blue Injection for the Treatment of Discogenic Low Back Pain.

    PubMed

    Zhang, XiaoJun; Hao, Jie; Hu, Zhenming; Yang, HaiTao

    2016-01-01

    Low back pain is a common worldwide health problem and has a significant socioeconomic impact on public health. Internal disc disruption has been considered as the most common cause of low back pain. Various therapies, including interbody fusion, disc replacement, injection therapies, and thermal annular procedures have been utilized for the treatment of discogenic low back pain. Recently, a new method of intradiscal methylene blue injection has been introduced to treat discogenic low back pain, but the clinical outcomes are controversial. To investigate the clinical outcomes and magnetic resonance imaging changes of intradiscal methylene blue injection for the treatment of discogenic low back pain. Observational study. An interventional low back pain management practice in a university hospital. A total of 33 patients were selected to be treated with intradiscal methylene blue injection. The clinical outcomes were evaluated by numeric rating scale and Oswestry Disability Index at pretreatment, one month, 3, 6, and 12 months after treatment. The magnetic resonance imaging changes of involved intervertebral discs were assessed by apparent diffusion coefficient and T2 values at pretreatment, 3, 6, and 12 months after treatment. All of the patients got a follow-up period up to 12 months. The mean numeric rating scale scores at pretreatment, one month, 3, 6, and 12 months after treatment were 6.54, 2.98, 3.23, 3.66, and 4.72, respectively. There was a minimum of 2 points reduction at one month, 3, and 6 months after treatment, but less than 2 points reduction at 12 months. There was at least 50% improvement on the Oswestry Disability Index at one month, 3, and 6 months after treatment, but not at 12 months. The mean apparent diffusion coefficient and T2 value were significantly higher at 6 and12 months after treatment compared to pretreatment, but there was no significant difference between pretreatment and 3 months after treatment. This is an observational study with a relatively small sample size and short-term follow-up. The intradiscal methylene blue injection might be an effective therapy for discogenic low back pain for the short-term and could improve disc degeneration condition to some extent.Key words: Low back pain, discogenic pain, internal disc disruption, provocation discography, methylene blue, intradiscal injection, disc degeneration, magnetic resonance, imaging.

  9. Inclinometer - Time Domain Reflectometry Comparative Study

    DOT National Transportation Integrated Search

    2004-12-01

    Four pairs of inclinometers and time domain reflectometry (TDR) cables were set up to make a side-by-side : comparison of the performance of these systems in detecting slippage of soils in the shoulders of State Route 124 : and State Route 338 in Mei...

  10. Inclinometer--time-domain reflectometry comparative study.

    DOT National Transportation Integrated Search

    2004-12-01

    Four pairs of inclinometers and time domain reflectometry (TDR) cables were set up to make a side-by-side : comparison of the performance of these systems in detecting slippage of soils in the shoulders of State Route 124 : and State Route 338 in Mei...

  11. The biomechanics of a multilevel lumbar spine hybrid using nucleus replacement in conjunction with fusion.

    PubMed

    Dahl, Michael C; Ellingson, Arin M; Mehta, Hitesh P; Huelman, Justin H; Nuckley, David J

    2013-02-01

    Degenerative disc disease is commonly a multilevel pathology with varying deterioration severity. The use of fusion on multiple levels can significantly affect functionality and has been linked to persistent adjacent disc degeneration. A hybrid approach of fusion and nucleus replacement (NR) has been suggested as a solution for mildly degenerated yet painful levels adjacent to fusion. To compare the biomechanical metrics of different hybrid implant constructs, hypothesizing that an NR+fusion hybrid would be similar to a single-level fusion and perform more naturally compared with a two-level fusion. A cadaveric in vitro repeated-measures study was performed to evaluate a multilevel lumbar NR+fusion hybrid. Eight cadaveric spines (L3-S1) were tested in a Spine Kinetic Simulator (Instron, Norwood, MA, USA). Pure moments of 8 Nm were applied in flexion/extension, lateral bending, and axial rotation as well as compression loading. Specimens were tested intact; fused (using transforaminal lumbar interbody fusion instrumentation with posterior rods) at L5-S1; with a nuclectomy at L4-L5 including fusion at L5-S1; with NR at L4-L5 including fusion at L5-S1; and finally with a two-level fusion spanning L4-S1. Repeated-measures analysis of variance and corrected t tests were used to statistically compare outcomes. The NR+fusion hybrid and single-level fusion exhibited no statistical differences for range of motion (ROM), stiffness, neutral zone, and intradiscal pressure in all loading directions. Compared with two-level fusion, the hybrid affords the construct 41.9% more ROM on average. Two-level fusion stiffness was statistically higher than all other constructs and resulted in significantly lower ROM in flexion, extension, and lateral bending. The hybrid construct produced approximately half of the L3-L4 adjacent-level pressures as the two-level fusion case while generating similar pressures to the single-level fusion case. These data portend more natural functional outcomes and fewer adjacent disc complications for a multilevel NR+fusion hybrid compared with the classical two-level fusion. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Southern Hemisphere origins for interannual variations of Tibetan Plateau snow cover in boreal summer

    NASA Astrophysics Data System (ADS)

    Wu, Z.

    2017-12-01

    The climate response to the Tibetan Plateau (TP) snow cover (TPSC) has been receiving extensive concern. However, relatively few studies have devoted to revealing the potential factors that can contribute to the TPSC variability on the interannual time scale. Especially during the boreal summer, snow cover can persist over the TP at high elevations, which exerts profound influences on the local and remote climate change. The present study finds that May Southern Hemisphere (SH) annular mode (SAM), the dominating mode of atmospheric circulation variability in the SH extratropics, exhibits a significant positive relationship with the boreal summer TPSC interannual variability. Observational analysis and numerical experiments manifest that the signal of May SAM can be "prolonged" by a meridional Indian Ocean tripole (IOT) sea surface temperature anomaly (SSTA) via atmosphere-ocean interaction. The IOT SSTA pattern persists into the following summer and excites anomalous local-scale zonal vertical circulation. Subsequently, a positive (or negative) tropical dipole rainfall (TDR) mode is induced with deficient (or sufficient) precipitation in tropical western Indian Ocean and sufficient (or deficient) precipitation in eastern Indian Ocean-Maritime continent. Rossby wave source diagnosis reveals that the wave energies, generated by the latent heat release of the TDR mode, propagate northward into western TP. As a response, abnormal cyclonic circulation and upward movement are triggered and prevail over western TP, providing favorable dynamical conditions for more TPSC, and vice versa. Hence, the IOT SSTA plays an "ocean bridge" role and the TDR mode acts as an "atmosphere bridge" role in the process of May SAM impacting the following summer TPSC variability. The results of our work may provide new insight about the cross-equatorial propagation of the SAM influence. Keywords Southern Hemisphere annular mode; Tibetan Plateau snow cover; Rossby wave source

  13. Inverse modeling of rainfall infiltration with a dual permeability approach using different matrix-fracture coupling variants.

    NASA Astrophysics Data System (ADS)

    Blöcher, Johanna; Kuraz, Michal

    2017-04-01

    In this contribution we propose implementations of the dual permeability model with different inter-domain exchange descriptions and metaheuristic optimization algorithms for parameter identification and mesh optimization. We compare variants of the coupling term with different numbers of parameters to test if a reduction of parameters is feasible. This can reduce parameter uncertainty in inverse modeling, but also allow for different conceptual models of the domain and matrix coupling. The different variants of the dual permeability model are implemented in the open-source objective library DRUtES written in FORTRAN 2003/2008 in 1D and 2D. For parameter identification we use adaptations of the particle swarm optimization (PSO) and Teaching-learning-based optimization (TLBO), which are population-based metaheuristics with different learning strategies. These are high-level stochastic-based search algorithms that don't require gradient information or a convex search space. Despite increasing computing power and parallel processing, an overly fine mesh is not feasible for parameter identification. This creates the need to find a mesh that optimizes both accuracy and simulation time. We use a bi-objective PSO algorithm to generate a Pareto front of optimal meshes to account for both objectives. The dual permeability model and the optimization algorithms were tested on virtual data and field TDR sensor readings. The TDR sensor readings showed a very steep increase during rapid rainfall events and a subsequent steep decrease. This was theorized to be an effect of artificial macroporous envelopes surrounding TDR sensors creating an anomalous region with distinct local soil hydraulic properties. One of our objectives is to test how well the dual permeability model can describe this infiltration behavior and what coupling term would be most suitable.

  14. Seasonal variations measured by TDR and GPR on an anthropogenic sandy soil and the implications for utility detection

    NASA Astrophysics Data System (ADS)

    Curioni, Giulio; Chapman, David N.; Metje, Nicole

    2017-06-01

    The electromagnetic (EM) soil properties are dynamic variables that can change considerably over time, and they fundamentally affect the performance of Ground Penetrating Radar (GPR). However, long-term field studies are remarkably rare and records of the EM soil properties and their seasonal variation are largely absent from the literature. This research explores the extent of the seasonal variation of the apparent permittivity (Ka) and bulk electrical conductivity (BEC) measured by Time Domain Reflectometry (TDR) and their impact on GPR results, with a particularly important application to utility detection. A bespoke TDR field monitoring station was specifically developed and installed in an anthropogenic sandy soil in the UK for 22 months. The relationship between the temporal variation of the EM soil properties and GPR performance has been qualitatively assessed, highlighting notably degradation of the GPR images during wet periods and a few days after significant rainfall events following dry periods. Significantly, it was shown that by assuming arbitrary average values (i.e. not extreme values) of Ka and BEC which do not often reflect the typical conditions of the soil, it can lead to significant inaccuracies in the estimation of the depth of buried targets, with errors potentially up to approximately 30% even over a depth of 0.50 m (where GPR is expected to be most accurate). It is therefore recommended to measure or assess the soil conditions during GPR surveys, and if this is not possible to use typical wet and dry Ka values reported in the literature for the soil expected at the site, to improve confidence in estimations of target depths.

  15. Patterns of entrapped air dissolution in a two-dimensional pilot-scale synthetic aquifer.

    PubMed

    McLeod, Heather C; Roy, James W; Smith, James E

    2015-01-01

    Past studies of entrapped air dissolution have focused on one-dimensional laboratory columns. Here the multidimensional nature of entrapped air dissolution was investigated using an indoor tank (180 × 240 × 600 cm(3) ) simulating an unconfined sand aquifer with horizontal flow. Time domain reflectometry (TDR) probes directly measured entrapped air contents, while dissolved gas conditions were monitored with total dissolved gas pressure (PTDG ) probes. Dissolution occurred as a diffuse wedge-shaped front from the inlet downgradient, with preferential dissolution at depth. This pattern was mainly attributed to increased gas solubility, as shown by PTDG measurements. However, compression of entrapped air at greater depths, captured by TDR and leading to lower quasi-saturated hydraulic conductivities and thus greater velocities, also played a small role. Linear propagation of the dissolution front downgradient was observed at each depth, with both TDR and PTDG , with increasing rates with depth (e.g, 4.1 to 5.7× slower at 15 cm vs. 165 cm depth). PTDG values revealed equilibrium with the entrapped gas initially, being higher at greater depth and fluctuating with the barometric pressure, before declining concurrently with entrapped air contents to the lower PTDG of the source water. The observed dissolution pattern has long-term implications for a wide variety of groundwater management issues, from recharge to contaminant transport and remediation strategies, due to the persistence of entrapped air near the water table (potential timescale of years). This study also demonstrated the utility of PTDG probes for simple in situ measurements to detect entrapped air and monitor its dissolution. © 2014 Her Majesty the Queen in Right of Canada Groundwater © 2014, National Ground Water Association.

  16. Deletion Analysis of the Tumorous-Head (tuh–3) Gene in DROSOPHILA MELANOGASTER

    PubMed Central

    Kuhn, David T.; Woods, Daniel F.; Andrew, Deborah J.

    1981-01-01

    In the presence of the naturally occurring maternal-effect alleles tuh-1h or tuh-1g, the tuh-3 mutant gene can cause the tumorous-head trait or the sac-testis trait. The tuh-3 gene functions as a semidominant in the presence of the tuh-1h maternal effect. Eye-antennal structures are replaced by posterior abdominal tergites and genital structures. If tuh-1h is replaced by its naturally occurring allele tuh-1g, tuh-3 functions as a recessive hypomorph and the defect switches from anterior to posterior structures, with a male genital-disc defect appearing with variable penetrance. Function and regulation of tuh-3+ may better be understood in light of the cytological localization of tuh-3 either adjacent to or as part of the bithorax complex. The tuh-3+ gene product appears to be essential for normal development, at least in the posterior end of the embryo. PMID:6804305

  17. Conservative and esthetic cast gold fixed partial dentures-inlay, onlay, and partial veneer retainers, custom composite pontics, and stress-breakers: part I: fundamental design principles.

    PubMed

    Stevenson, Richard G; Refela, Jane A

    2009-01-01

    Although in today's dental world implant restorations are considered the standard of care in the replacement of missing teeth, clinical contraindications and patient nonacceptance of implant placement can be encountered. Several scenarios are discussed here in which a single missing tooth can be restored with conservative fixed partial dentures (FPD) that employ cast gold retainers; each with a customized design in order to preserve tooth structure, maintain esthetics, and provide a long-term prognosis. The abutment teeth are prepared for conservative partial coverage restorations by using Brasseler burs (Brasseler USA, Savannah, GA, USA). Impressions are taken of the preparations, along with any retentive features, utilizing either the Vented Pin Channel technique or the Shooshan Plastic Pin technique. The latter technique utilizes Kodex twist drills and corresponding impression pins (Coltene Whaledent Inc., Mahwah, NJ, USA). The conservative FPD with non-rigid connectors is fabricated by using type III gold alloy. The pontic cage portion is chemically prepared utilizing the Panavia F2.0 cement kit (Kuraray America Inc., Houston, TX, USA) or other dual-polymerizing resin cement and restored with any type of direct composite resin material. A palette of opaquers and tints are used for chairside characterization of the esthetic pontic facing. The final polish of the pontic is completed by using FlexiDisc and FlexiBuff discs (Cosmedent Inc., Chicago, IL, USA). CLINICAL SIGNIFICANCE In cases where an implant restoration is contraindicated for replacement of a single tooth, a semi-precision FPD is a conservative, functional, and esthetic alternative.

  18. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    PubMed

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Cervical Disk Replacement With Discover Versus Fusion in a Single-Level Cervical Disk Disease: A Prospective Single-Center Randomized Trial With a Minimum 2-Year Follow-up.

    PubMed

    Rožanković, Marjan; Marasanov, Sergej M; Vukić, Miroslav

    2017-06-01

    Prospective randomized study. To compare the clinical outcome after Discover arthroplasty versus anterior cervical discectomy and fusion (ACDF) in patients treated for symptomatic single-level cervical disk disease. ACDF is still the gold standard for surgical treatment of cervical spine degenerative disk disease. However, results of many studies suggest that it may cause degenerative changes at levels immediately above and below the fusion, known as adjacent segment degenerative disease. Cervical arthroplasty has recently been introduced as an alternative to standard procedure of ACDF. It showed decreased surgical morbidity, decreased complications from postoperative immobilization, and an earlier return to previous level of function. A total of 105 consecutive patients with single-level cervical disk disease, producing radiculopathy and/or myelopathy were randomly divided into groups to undergo ACDF or Discover arthroplasty. All patients were evaluated with preoperative and postoperative serial radiographic studies and clinically, using Neck Disability Index, Visual Analog Scale and neurological status at 3, 6, 12, and 24 months. The results of our study indicate that cervical arthroplasty using Discover Artificial Cervical Disc provides favorable clinical and radiologic outcomes in a follow-up period of 24 months. There has been significant improvement in clinical parameters, Visual Analog Scale and Neck Disability Index, at 3, 6, 12, and 24 months in arthroplasty group comparing to control group. The Discover artificial cervical disc replacement offers favorable outcome compared with ACDF for a single-level cervical disk disease at short-term and long-term follow-up.

  20. Understanding United States Investigational Device Exemption Studies-Clinical Relevance and Importance for Healthcare Economics.

    PubMed

    Ament, Jared D; Mollan, Scott; Greenan, Krista; Binyamin, Tamar; Kim, Kee D

    2017-06-01

    The US Food and Drug Administration allows a previously unapproved device to be used clinically to collect safety and effectiveness data under their Investigational Device Exemption (IDE) category. The process usually falls under 3 different trial categories: noninferiority, equivalency, and superiority. To confidently inform our patients, understanding the basic concepts of these trials is paramount. The purpose of this manuscript was to provide a comprehensive review of these topics using recently published IDE trials and economic analyses of cervical total disc replacement as illustrative examples. In 2006, an IDE was initiated to study the safety and effectiveness of total disc replacement controlled against the standard of care, anterior cervical discectomy, and fusion. Under the IDE, randomized controlled trials comparing both 1 and 2 level cervical disease were completed. The sponsor designed the initial trial as noninferiority; however, using adaptive methodology, superiority could be claimed in the 2-level investigation. Healthcare economics are critical in medical decision making and reimbursement practices. Once both cost- and quality-adjusted life-year (QALY) are known for each patient, the incremental cost-effectiveness ratio is calculated. Willingness-to-pay is controversial, but a commonly cited guideline considers interventions costing below 20 000 $/QALY strongly cost effective and more than 100 000 $/QALY as not cost effective. While large Food and Drug Administration IDE studies are often besieged by complex statistical considerations and calculations, it is fundamentally important that clinicians understand at least the terminology and basic concepts on a practical level. Copyright © 2017 by the Congress of Neurological Surgeons

  1. [Effect of Basic Fibroblast Growth Factor and Transforming Growth Factor-Β1 Combined with Bone Marrow Mesenchymal Stem Cells on the Repair of Degenerated Intervertebral Discs in Rat Models].

    PubMed

    Jiang, Chao; Li, Da-peng; Zhang, Zhi-jian; Shu, Hao-ming; Hu, Lang; Li, Zheng-nan; Huang, Yong-hui

    2015-08-01

    To evaluate the effects of the combination of basic fibroblast growth factor (bFGF), transforming growth factor-Β1 (TGF-Β1), bone marrow mesenchymal stem cells (BMSCs), and temperature-responsive chitosan hydrogel (TCH) gel on the repair of degenerative intervertebral disc in rat models. Rat models of intervertebral disc degeneration were established by acupuncture. The degenerative effects were observed under magnetic resonance imaging (MRI). The BMSCs was cultured in vitro and then transfected by adenovirus with enhanced green fluorescent protein to make it carry the gene of enhanced green fluorescent protein,which functioned as fluorescence labeling. The SD rat models of intervertebral disc degeneration were divided into four groups: group A, treated with the combination of bFGF, TGF-Β1,BMSCs,and TCH gel; group B, treated with the combination of BMSCs and TCH gel;group C, treated with the combination of bFGF,TGF-Β1, and TCH gel;and group D, treated with PBS buffer solution. After the corresponding reagents were injected into the degenerative intervertebral discs of each group, the rats were cultivated for another four weeks and then the repair effects of the intervertebral discs were observed under MRI. Furthermore,the intervertebral discs of each group were taken out and observed by HE and Masson staining. The nucleus pulposus was aspirated and the expressions of aggrecan,collagen 2,Sox-9,and collagen I of nucleus pulposus of each group were tested by reverse transcription polymerase chain reaction and Western blot. The transplanted BMSCs survived in the intervertebral disc and differentiated into nucleus pulposus-like cells. MRI showed that:the signal intensity of the nucleus pulposus of group A was much higher than that of the rest groups, the signal intensity of group B was higher than that of group C, and the signal intensity of group D was the lowest,in which the dura mater spinalis was in compression and the spinal cord changed in beaded shape. The differences of the Pfirrmann grading among the four groups had statistical significance (P<0.05). The results of the HE and Masson stains showed:the intervertebral disc of group A was well-structured,the quantity of nucleus pulposus cells was larger than that of the other three groups,and the boundary between the nucleus pulposus and the annulus fibrosus was clearly defined;the quantity of the nucleus pulposus cells of group B was larger than that of group C, and the broken annulus fibrosus was not observed in group B, while the broken annulus fibrosus could be observed in group C; and, the nucleus pulposus cells of group D were replaced by fibrous tissue. The results of the reverse transcription polymerase chain reaction and Western blot tests showed that,in terms of the expressions of aggrecan,collagen 2 and Sox-9,group A was the highest, followed by group B,group C,and group D (P<0.05); in terms of the expression of collagen 1,there was no obvious difference among these four groups (P>0.05). The transplanted BMSCs can survive in the degenerative intervertebral disc and differentiate into nucleus pulposus-like cells. The combination of bFGF, TGF-Β1, BMSCs,and TCH gel has obvious repair effect on the degenerative intervertebral discs. The effect of the combination of BMSCs and TCH gel on transplantation therapy of the degenerative intervertebral discs is better than that of the combination of bFGF, TGF-Β1 and TCH gel but worse than that of the combination of bFGF, TGF-Β1, BMSCs, and TCH gel.

  2. Evaluation of Tag Attachments on Small Cetaceans

    DTIC Science & Technology

    2013-09-30

    silicon-based antifouling coating, “Propspeed,” as a means to further reduce drag and improve tag performance. Examples of the experimental tags are...the TDR tags, prepared by Wildlife Computers (Figure 1). Half of these were treated with Propspeed antifouling coating, and the other half were left

  3. Field tests of a down-hole TDR profiling water content measurement system

    USDA-ARS?s Scientific Manuscript database

    Accurate soil profile water content monitoring at multiple depths has previously been possible only using the neutron probe (NP), but with great effort and at unsatisfactory intervals. Despite the existence of several capacitance systems for profile water content measurements, accuracy and spatial r...

  4. The use of recycled concrete aggregate in a dense graded aggregate base course.

    DOT National Transportation Integrated Search

    2008-03-01

    The research project was broken up into 2 different parts. The first part involved evaluating the potential use of the Time : Domain Reflectometry, TDR (ASTM D6780), as a non-nuclear means for determining the dry density and moisture content of : gra...

  5. Effects of Multiple Crimps and Cable Length on Reflection Signatures from Long Cables

    DOT National Transportation Integrated Search

    2002-03-19

    The accuracy of time domain reflectometry (TDR) measurements of rock shearing with cable lengths greater than 60 m has not been adequately documented. This paper presents the results of controlled crimping and shearing of a 530 m long, 22.2mm diamete...

  6. Sustainable smallholder intensification through improved water management requires adjusted fertilizer recommendation

    NASA Astrophysics Data System (ADS)

    Gedfew, Muluye; Schmitter, Petra; Nakawuka, Prossie; Tilahun, Seifu A.; Steenhuis, Tammo; Langan, Simon

    2017-04-01

    In Sub-Saharan Africa small scale irrigation is developing rapidly. Whilst emphasis is mainly placed on water resource availability and access for irrigation, less attention is paid to the interaction of water management on nutrient balances. The quality and quantity of irrigation water delivered to the field not only controls the nutrient flow dynamic system in the soil media but also affects production and uptake. The objective of this study is to evaluate the effect of different water management methods on partial nutrient balances in irrigated fields of the Ethiopian highlands. The study was conducted during the dry season of 2016 where farmers cultivated consecutively tomato and pepper. Farmers were grouped into three water management treatments: irrigation based on Time Domain reflect meter (TDR), on the standard crop water requirements (CWR) and the traditional farmers practice (FARM). The average water consumption for tomato in the CWR, TDR and FARM groups were 590 mm, 476 mm and 575 mm, respectively. The comparison of the water use at different stages showed that traditional farmer practice used less water at the initial stage and more water at the maturity stage which influenced the crop yield and the nutrient dynamics of NPK. For pepper, the linkage to the supplemental irrigation was slightly different due to the onset of the rainy season. The average tomato yield obtained in the farmer practice plots was 20.8 Mg ha-1 which was significantly lower than those obtained in the TDR (31.67 Mg ha-1) and the CWR (33.2 Mg ha-1) plots. The average partial nitrogen (N) depletion balance obtained for tomato in the TDR, CWR and FARM treatment were -91 kg ha-1, -151 kg ha-1 and 19 kg ha-1 respectively. For phosphorus (P) the calculated depletion balance was -0.6 kg ha-1, -0.5 kg ha-1, and - 0.2 kg ha-1, respectively whereas for potassium (K) the balances were largely negative (i.e. -284 kg ha-1, -270 kg ha-1 and -97 kg ha-1, respectively). Similar observations were found for pepper. The N and K balances were less negative when farmers used organic fertilizers aside from inorganic fertilizers compared to those farmers who only applied Urea and Di-Ammonium Phosphate (DAP). Furthermore, the largest negative nutrient balances were obtained for the water management leading to the highest crop and water productivity (i.e. CWR). Hence, introducing sustainable water management practices in irrigation requires associated fertilizer recommendations to compensate for the increased yields obtained, avoiding land degradation in the long term.

  7. Applications of 3D printing in the management of severe spinal conditions.

    PubMed

    Provaggi, Elena; Leong, Julian J H; Kalaskar, Deepak M

    2017-06-01

    The latest and fastest-growing innovation in the medical field has been the advent of three-dimensional printing technologies, which have recently seen applications in the production of low-cost, patient-specific medical implants. While a wide range of three-dimensional printing systems has been explored in manufacturing anatomical models and devices for the medical setting, their applications are cutting-edge in the field of spinal surgery. This review aims to provide a comprehensive overview and classification of the current applications of three-dimensional printing technologies in spine care. Although three-dimensional printing technology has been widely used for the construction of patient-specific anatomical models of the spine and intraoperative guide templates to provide personalized surgical planning and increase pedicle screw placement accuracy, only few studies have been focused on the manufacturing of spinal implants. Therefore, three-dimensional printed custom-designed intervertebral fusion devices, artificial vertebral bodies and disc substitutes for total disc replacement, along with tissue engineering strategies focused on scaffold constructs for bone and cartilage regeneration, represent a set of promising applications towards the trend of individualized patient care.

  8. Growth of magnesium diboride films on 2 inch diameter copper discs by hybrid physical–chemical vapor deposition

    DOE PAGES

    Withanage, Wenura K.; Xi, X. X.; Nassiri, Alireza; ...

    2017-02-16

    Here, magnesium diboride (MgB 2) coating is a potential candidate to replace bulk niobium (Nb) for superconducting radio frequency cavities due to the appealing superconducting properties of MgB 2. MgB 2 coating on copper may allow cavity operation near 20–25 K as a result of the high transition temperature (T c) of MgB 2 and excellent thermal conductivity of Cu. We have grown MgB 2 films on 2 inch diameter Cu discs by hybrid physical–chemical vapor deposition for radio frequency characterization. Structural and elemental analyses showed a uniform MgB 2 coating on top of a Mg–Cu alloy layer with occasionalmore » intrusion of Mg–Cu alloy regions. High T c values of around 37 K and high critical current density (J c) on the order of 107 A cm –2 at zero field were observed. Radio frequency measurements at 11.4 GHz confirmed a high T c and showed a quality factor (Q 0) much higher than for Cu and close to that of Nb.« less

  9. Growth of magnesium diboride films on 2 inch diameter copper discs by hybrid physical–chemical vapor deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Withanage, Wenura K.; Xi, X. X.; Nassiri, Alireza

    Here, magnesium diboride (MgB 2) coating is a potential candidate to replace bulk niobium (Nb) for superconducting radio frequency cavities due to the appealing superconducting properties of MgB 2. MgB 2 coating on copper may allow cavity operation near 20–25 K as a result of the high transition temperature (T c) of MgB 2 and excellent thermal conductivity of Cu. We have grown MgB 2 films on 2 inch diameter Cu discs by hybrid physical–chemical vapor deposition for radio frequency characterization. Structural and elemental analyses showed a uniform MgB 2 coating on top of a Mg–Cu alloy layer with occasionalmore » intrusion of Mg–Cu alloy regions. High T c values of around 37 K and high critical current density (J c) on the order of 107 A cm –2 at zero field were observed. Radio frequency measurements at 11.4 GHz confirmed a high T c and showed a quality factor (Q 0) much higher than for Cu and close to that of Nb.« less

  10. Growth of magnesium diboride films on 2 inch diameter copper discs by hybrid physical–chemical vapor deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Withanage, Wenura K.; Xi, X. X.; Nassiri, Alireza

    Magnesium diboride (MgB2) coating is a potential candidate to replace bulk niobium (Nb) for superconducting radio frequency cavities due to the appealing superconducting properties of MgB2. MgB2 coating on copper may allow cavity operation near 20–25 K as a result of the high transition temperature (T c) of MgB2 and excellent thermal conductivity of Cu. We have grown MgB2 films on 2 inch diameter Cu discs by hybrid physical–chemical vapor deposition for radio frequency characterization. Structural and elemental analyses showed a uniform MgB2 coating on top of a Mg–Cu alloy layer with occasional intrusion of Mg–Cu alloy regions. High Tmore » c values of around 37 K and high critical current density (J c) on the order of 107 A cm-2 at zero field were observed. Radio frequency measurements at 11.4 GHz confirmed a high T c and showed a quality factor (Q 0) much higher than for Cu and close to that of Nb.« less

  11. Percutaneous Transcatheter One-Step Mechanical Aortic Disc Valve Prosthesis Implantation: A Preliminary Feasibility Study in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav

    Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less

  12. Biologic canine and human intervertebral disc repair by notochordal cell-derived matrix: from bench towards bedside.

    PubMed

    Bach, Frances C; Tellegen, Anna R; Beukers, Martijn; Miranda-Bedate, Alberto; Teunissen, Michelle; de Jong, Willem A M; de Vries, Stefan A H; Creemers, Laura B; Benz, Karin; Meij, Björn P; Ito, Keita; Tryfonidou, Marianna A

    2018-05-29

    The socioeconomic burden of chronic back pain related to intervertebral disc (IVD) disease is high and current treatments are only symptomatic. Minimally invasive strategies that promote biological IVD repair should address this unmet need. Notochordal cells (NCs) are replaced by chondrocyte-like cells (CLCs) during IVD maturation and degeneration. The regenerative potential of NC-secreted substances on CLCs and mesenchymal stromal cells (MSCs) has already been demonstrated. However, identification of these substances remains elusive. Innovatively, this study exploits the regenerative NC potential by using healthy porcine NC-derived matrix (NCM) and employs the dog as a clinically relevant translational model. NCM increased the glycosaminoglycan and DNA content of human and canine CLC aggregates and facilitated chondrogenic differentiation of canine MSCs in vitro . Based on these results, NCM, MSCs and NCM+MSCs were injected in mildly (spontaneously) and moderately (induced) degenerated canine IVDs in vivo and, after six months of treatment, were analyzed. NCM injected in moderately (induced) degenerated canine IVDs exerted beneficial effects at the macroscopic and MRI level, induced collagen type II-rich extracellular matrix production, improved the disc height, and ameliorated local inflammation. MSCs exerted no (additive) effects. In conclusion, NCM induced in vivo regenerative effects on degenerated canine IVDs. NCM may, comparable to demineralized bone matrix in bone regeneration, serve as 'instructive matrix', by locally releasing growth factors and facilitating tissue repair. Therefore, intradiscal NCM injection could be a promising regenerative treatment for IVD disease, circumventing the cumbersome identification of bioactive NC-secreted substances.

  13. Leaflet embolisation from Duromedics valves: a report of two cases.

    PubMed

    Kumar, N; Balasundaram, S; Rickard, M; al Halees, Z; Duran, C M

    1991-12-01

    Embolization of parts of mechanical valves has been reported since the inception of prosthetic valve implantation. We report here two cases of embolization of one hemileaflet of a Duromedic bileaflet prosthesis in the mitral position due to a pivot fracture. Both presented with moderately severe mitral regurgitation and pulmonary edema and were successfully managed by replacement of the malfunctioning prostheses. The embolised disc was located in the left common iliac artery by abdominal ultrasound and removed by an inguinal, retroperitoneal approach with low morbidity. Both patients left hospital and are doing well to-date.

  14. Validation of Tethya samaaii Ribeiro & Muricy, 2011, replacement name for the sponge Tethya rubra Samaai & Gibbons, 2005 (Demospongiae, Tethyida, Tethyidae).

    PubMed

    Samaai, Toufiek; Gibbons, Mark J; Muricy, Guilherme

    2017-11-14

    Tethya samaaii Ribeiro & Muricy, 2011 is a massive, irregularly globular or sub-spherical sponge with basal rooting processes or a disc-like attachment (Figure 1A). It was described from Oudekraal, on the west coast of South Africa as Tethya rubra Samaai & Gibbons, 2005 based on specimens collected during two surveys in 1996 (Samaai & Gibbons 2005). This species was later reported from Algoa Bay, on the southeast coast of South Africa by Waterworth et al. (2017).

  15. Improved theory of time domain reflectometry with variable coaxial cable length for electrical conductivity measurements

    USDA-ARS?s Scientific Manuscript database

    Although empirical models have been developed previously, a mechanistic model is needed for estimating electrical conductivity (EC) using time domain reflectometry (TDR) with variable lengths of coaxial cable. The goals of this study are to: (1) derive a mechanistic model based on multisection tra...

  16. --No Title--

    Science.gov Websites

    interoperability emerging infrastructure for data management on computational grids Software Packages Services : ATLAS: Management and Steering: Computing Management Board Software Project Management Board Database Model Group Computing TDR: 4.5 Event Data 4.8 Database and Data Management Services 6.3.4 Production and

  17. Should Project Managers Buy Technical Data

    DTIC Science & Technology

    2017-04-06

    Should Project Managers Buy Technical Data? Jerry Harper April 6, 2017 PUBLISHED BY The Defense...intellectual property (IP) management and technical data rights (TDR) strategies. According to DoD Instruction 5000.02 (DoD, 2017), project managers (PMs...Defense Authorization Act NDI ................nondevelopmental item PM ................. project manager R&D ...............research and development

  18. Profiling soil water content sensor

    USDA-ARS?s Scientific Manuscript database

    A waveguide-on-access-tube (WOAT) sensor system based on time domain reflectometry (TDR) principles was developed to sense soil water content and bulk electrical conductivity in 20-cm (8 inch) deep layers from the soil surface to depths of 3 m (10 ft) (patent No. 13/404,491 pending). A Cooperative R...

  19. LUX-ZEPLIN (LZ) Technical Design Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mount, B. J.

    In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

  20. Status Of the ILC Main Linac Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, Arun; Kapin, Valery; Solyak, Nikolay

    2017-05-01

    International Linear collider (ILC) is a proposed accelerator facility which is primarily based on two 11-km long superconducting main linacs. In this paper we present recent updates on the main linac design and discuss changes made in order to meet specification outlined in the technical design report (TDR).

  1. INFLUENCE OF LIGHT ON BACTERIOPLANKTON PRODUCTION AND RESPIRATION IN A SUBTROPICAL CORAL REEF

    EPA Science Inventory

    The influence of sunlight on bacterioplankton production (14C-leucine (Leu) and 3H-thymidine (TdR) incorporation; changes in cell abundances) and O2 consumption was investigated in a shallow subtropical coral reef located near Key Largo, Florida. Quartz (light) and opaque (dark) ...

  2. Selected nursery projects at the Missoula Technology and Development Center

    Treesearch

    Brian Vachowski

    2007-01-01

    The USDA Forest Service Missoula Technology and Development Center (MTDC) offers technical expertise, technology transfer, and new equipment development to federal, state, and private forest nurseries. Current and recently completed projects at MTDC include a container block steam sterilizer, shielded herbicide sprayer, time-domain reflectometry (TDR) nursery soil...

  3. No tillage effect on water retention characteristics of soil aggregates in rainfed semiarid conditions.

    NASA Astrophysics Data System (ADS)

    Blanco-Moure, Nuria; López, M. Victoria; Moret, David

    2010-05-01

    The evaluation of changes in soil moisture retention characteristics associated to alterations in soil structure is of great interest in tillage studies. Most of these studies have evaluated soil properties in samples of total soil but not in individual aggregates. However, soil behavior at a macroscale level depends on the aggregate properties. A better knowledge of aggregate characteristics, as the water retention properties, will help to explain, for example, the response of soil to tillage, compaction and crop growth, and hence, to plan adequate soil management practices. In this study we determine the water retention curve of soil aggregates of different sizes from a soil under two tillage systems (conventional and no tillage). The study was carried out in a silty clay loam soil of semiarid Aragon (NE Spain). Two tillage systems were compared: no tillage (NT) and conventional tillage with mouldboard plough (CT). Water retention curves (WRC) were determined for soil surface aggregates (0-5 cm) of three different sizes (8-4, 4-2 and 2-1 mm in diameter) by using the TDR-pressure cell (Moret et al. 2008. Soil Till. Res, 100, 114-119). The TDR-pressure cell is a non-destructive method which permits determining WRC with the only one and same soil sample. Thus, the pressure cell was filled with aggregates up to 4 cm height, weighted and wetted to saturation from the bottom. Pressure steps were sequentially applied at -0.5, -1.5, -3, -5, -10, -33, -100, -300 kPa, and water content of each aggregate sample was measured gravimetrically and by TDR 24 h after starting each pressure head step. The volume of the sample within the cell was also determined at this moment in order to obtain the bulk density and thus calculate the volumetric water content. A good relationship was obtained between the volumetric water content calculated from the gravimetric water content and the corresponding values measured by TDR (r2=0.907; p≤0.05). Within the same tillage treatment, no significant differences in WRC were found among soil aggregate sizes. Soil aggregates under CT retained more water at lower pressure heads in all aggregate sizes; in contrast the retention was more effective in those from NT at high pressure level. The extensive structural degradation of the CT aggregates observed during wetting with the consequent decrease in the soil volume within the transparent cell, can help to explain the different behaviour of both soils. The CT aggregates were probably disintegrated by slaking, causing a reduction in water drainage and, therefore, an increase in soil water content at low pressure heads. This idea was also confirmed with the application of the double exponential function proposed by Dexter et al. (2008. Geoderma 173, 243-253). The WRC curves measured by TDR were successfully fitted to the theoretical model proposed by Dexter (r2=0.986; p≤0.05). Thus, the model estimated that the large porosity between aggregates retain slightly more water under CT (0.36-0.39 m3 m-3) than under NT (0.31-0.35 m3 m-3). On the contrary, pores inside the aggregates tend to storage more water in NT (0.16-0.20 m3 m-3vs. 0.13-0.17 m3 m-3 in CT). These results show the suitability of NT to reduce the risk of soil crusting and compaction in agricultural lands of Aragón.

  4. A new strips tracker for the upgraded ATLAS ITk detector

    NASA Astrophysics Data System (ADS)

    David, C.

    2018-01-01

    The ATLAS detector has been designed and developed to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This document gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

  5. Does postmenopausal hormone replacement therapy affect intraocular pressure?

    PubMed

    Abramov, Yoram; Borik, Sharon; Yahalom, Claudia; Fatum, Muhammad; Avgil, Gadiel; Brzezinski, Amnon; Banin, Eyal

    2005-08-01

    To assess the effects of postmenopausal hormone replacement therapy (HRT) on intraocular pressure (IOP). This was a cross-sectional controlled study, including 107 women aged 60 to 80 years receiving HRT and 107 controls who have never received HRT. All subjects underwent IOP assessment and funduscopic photography for cup-to-disc (C/D) ratios, and completed questionnaires regarding personal and family history of glaucoma, hormone replacement therapy, lifetime estrogen and progesterone exposure, and cardiovascular risk factors. Main Outcome Measures included IOP, prevalence of increased IOP, and C/D ratios. The groups did not differ in mean IOP (15.3 versus 15.3 mm Hg), mean vertical (0.18 versus 0.21) and horizontal (0.17 versus 0.14) C/D ratios, and in prevalence of increased IOP (15% versus 14%), C/D ratio (7% versus 7%), or glaucoma (9% versus 11%). A personal history of ischemic heart disease was the only risk factor associated with increased IOP (O.R. = 4.63, P = 0.003). Lifetime estrogen and progesterone exposure, including pregnancies, deliveries, menstruation years, and the use of oral contraceptives did not significantly affect the risk for increased IOP. Hormone replacement therapy and lifetime estrogen and progesterone exposure do not seem to affect IOP or the risk for increased IOP. A personal history of ischemic heart disease may be associated with a higher risk for this disorder.

  6. Design and field tests of a directly coupled waveguide-on-access-tube soil water sensor

    USDA-ARS?s Scientific Manuscript database

    Sensor systems capable of monitoring soil water content can provide a useful tool for irrigation control. Current systems are limited by installation depth, labor, accuracy, and cost. Time domain reflectometry (TDR) is an approach for monitoring soil water content that relates the travel time of an ...

  7. 77 FR 4927 - Loan Workouts and Nonaccrual Policy, and Regulatory Reporting of Troubled Debt Restructured Loans

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... modified loans totaling $2.2 billion, which equates to a 16.42 percent delinquency rate for these loans. \\2... maintain separate, manual delinquency computations and nonaccrual schedules. In response to feedback from... reporting requirement and allow delinquency on TDR loans to be calculated consistent with loan contract...

  8. Field performance of three real-time moisture sensors in sandy loam and clay loam soils

    USDA-ARS?s Scientific Manuscript database

    The study was conducted to evaluate HydraProbe (HyP), Campbell Time Domain Reflectometry (TDR) and Watermarks (WM) moisture sensors for their ability to estimate water content based on calibrated neutron probe measurements. The three sensors were in-situ tested under natural weather conditions over ...

  9. Feasibility of using cone penetrometer truck (CPT) to install time domain reflectometry (TDR) and fiber optic slope failure detectors in pavement structures.

    DOT National Transportation Integrated Search

    2011-02-01

    A new method of cable installation using a heavy-duty Cone Penetration Test : (CPT) truck was developed and practiced successfully in this study. The coaxial and fiber : optic cables were pushed along with the cone rods by the hydraulic system integr...

  10. Rapid screening of fatty acid alkyl esters in olive oils by time domain reflectometry.

    PubMed

    Berardinelli, Annachiara; Ragni, Luigi; Bendini, Alessandra; Valli, Enrico; Conte, Lanfranco; Guarnieri, Adriano; Toschi, Tullia Gallina

    2013-11-20

    The main aim of the present research is to assess the possibility of quickly screening fatty acid alkyl esters (FAAE) in olive oils using time domain reflectometry (TDR) and partial least-squares (PLS) multivariate statistical analysis. Eighteen virgin olive oil samples with fatty acid alkyl ester contents and fatty acid ethyl ester/methyl ester ratios (FAEE/FAME) ranging from 3 to 100 mg kg(-1) and from 0.3 to 2.6, respectively, were submitted to tests with time domain resolution of 1 ps. The results obtained in test set validation demonstrated that this new and fast analytical approach is able to predict FAME, FAEE, and FAME + FAEE contents with R(2) values of 0.905, 0.923, and 0.927, respectively. Further measurements on mixtures between olive oil and FAAE standards confirmed that the prediction is based on a direct influence of fatty acid alkyl esters on the TDR signal. The suggested technique appeared potentially suitable for monitoring one of the most important quality attribute of the olive oil in the extraction process.

  11. The International Linear Collider Technical Design Report - Volume 2: Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baer, Howard; Barklow, Tim; Fujii, Keisuke

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  12. The International Linear Collider Technical Design Report - Volume 4: Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behnke, Ties

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  13. Effect of temperature, high pressure and freezing/thawing of dry-cured ham slices on dielectric time domain reflectometry response.

    PubMed

    Rubio-Celorio, Marc; Garcia-Gil, Núria; Gou, Pere; Arnau, Jacint; Fulladosa, Elena

    2015-02-01

    Dielectric Time Domain Reflectometry (TDR) is a useful technique for the characterization and classification of dry-cured ham according to its composition. However, changes in the behavior of dielectric properties may occur depending on environmental factors and processing. The effect of temperature, high pressure (HP) and freezing/thawing of dry-cured ham slices on the obtained TDR curves and on the predictions of salt and water contents when using previously developed predictive models, was evaluated in three independent experiments. The results showed that at temperatures below 20 °C there is an increase of the predicted salt content error, being more important in samples with higher water content. HP treatment caused a decrease of the reflected signal intensity due to the major mobility of available ions promoting an increase of the predicted salt content. Freezing/thawing treatment caused an increase of the reflected signal intensity due to the microstructural damages and the loss of water and ions, promoting a decrease of the predicted salt content.

  14. Spallation Neutron Source Second Target Station Integrated Systems Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ankner, John Francis; An, Ke; Blokland, Willem

    The Spallation Neutron Source (SNS) was designed from the beginning to accommodate both an accelerator upgrade to increase the proton power and a second target station (STS). Four workshops were organized in 2013 and 2014 to identify key science areas and challenges where neutrons will play a vital role [1-4]. Participants concluded that the addition of STS to the existing ORNL neutron sources was needed to complement the strengths of High Flux Isotope Reactor (HFIR) and the SNS first target station (FTS). To address the capability gaps identified in the workshops, a study was undertaken to identify instrument concepts thatmore » could provide the required new science capabilities. The study outlined 22 instrument concepts and presented an initial science case for STS [5]. These instrument concepts formed the basis of a planning suite of instruments whose requirements determined an initial site layout and moderator selection. An STS Technical Design Report (TDR) documented the STS concept based on those choices [6]. Since issue of the TDR, the STS concept has significantly matured as described in this document.« less

  15. Chronology of Late Quaternary Glacial Cycles in the Bering Trough, Gulf of Alaska: Constraints from Core-Log-Seismic Integration across the Continental Shelf and Slope

    NASA Astrophysics Data System (ADS)

    Clary, W. A.; Worthington, L. L.; Daigle, H.; Slagle, A. L.; Gulick, S. P. S.

    2016-12-01

    Sediments offshore Southern Alaska offer a natural laboratory to study glacial erosion, sediment deposition, and orogenesis. A major goal of Integrated Ocean Drilling Program (IODP) Expedition 341 was investigation of interrelationships among tectonic processes, paleoclimate, and glacial activity. Here, we focus on core-log-seismic integration of IODP Sites U1420 and U1421 on the shallow shelf and slope near the Bering Trough, a glacially derived shelf-crossing landform. These sites sample glacial and marine sediments that record a history of sedimentation following the onset of glacial intensification near the mid-Pleistocene transition (1.2 Ma) and Yakutat microplate convergence with North America. Ocean drilling provides important stratigraphic, physical properties, and age data in depth which support development of a stratigraphic model that can be extended across the shelf if carefully calibrated to local and regional seismic surveys. We use high resolution multichannel seismic, core, and logging data to develop a time-depth relationship (TDR) and update the developing chronostratigraphic model based on correlation of seismic sequence boundaries and drilling-related data, including biostratigraphic and paleomagnetic age controls. We calibrate, combine, and interpolate core and logging data at each site to minimize gaps in physical property information and generate synthetic seismic traces. At Site U1421, vertical seismic profiling further constrains the TDR, and provides input for the initial velocity model during the tie. Finally, we match reflectors in the synthetic trace with events in nearby seismic reflection data to establish a TDR at each site. We can use this relationship to better interpret the development of the Bering Trough, a recurring and favored path for ice streams and glacial advance. Initial results suggest late Pleistocene sedimentation rates of at least 1 km/m.y. on average, and variable sedimentation rates which are possibly correlated with paleoenvironmental indicators such as sea ice related species of diatoms.

  16. The effect of transmitted HIV-1 drug resistance on pre-therapy viral load.

    PubMed

    Harrison, Linda; Castro, Hannah; Cane, Patricia; Pillay, Deenan; Booth, Clare; Phillips, Andrew; Geretti, Anna Maria; Dunn, David

    2010-07-31

    Reduced replication capacity of viruses expressing drug resistant mutations implies that patients with transmitted drug resistance (TDR) could have lower HIV RNA viral load than those infected with wild-type virus. We performed analysis using data from the UK HIV Drug Resistance Database and the UK CHIC study. Eligible patients had a resistance test performed between 1997 and 2007 while naive to antiretroviral therapy, were 16 years or older, and had a viral load and CD4 cell count measurement within 6 months of this test. Models were adjusted for CD4 cell count, viral subtype, ethnicity, risk group, sex, age, calendar year, clinical centre, and viral load assay. Of a total of 7994 patients included, 709 (9%) had TDR: 604 (85%) had resistance to one drug class only [350 nucleos(t)ide reverse transcriptase inhibitors (NRTIs), 164 non-nucleos(t)ide reverse transcriptase inhibitors (NNRTIs), 90 protease inhibitors (PIs)], 77 (11%) to two classes (42 NRTIs/NNRTIs, 31 NRTIs/PIs, 4 NNRTIs/PIs), and 28 (4%) had resistance to all three classes. The overall mean (SD) viral load at the time of resistance testing was 4.60 (0.82) log(10) copies/ml, and did not differ by class of TDR. However, patients harbouring M184V/I (n = 61) had a significantly lower viral load [adjusted mean difference -0.33 log10 copies/ml (95% CI -0.54 to -0.11), 53% lower (95% CI 22 to 71%), P = 0.002] compared to wild-type virus. Our study provides clear evidence of an in-vivo fitness cost associated with the M184V/I mutation independent of drug effects which select for this mutation. This was not observed for any other mutation, but true effects may have been obscured by reversion of initially resistant viruses to wild-type.

  17. Individual dietary specialization and dive behaviour in the California sea otter: Using archival time depth data to detect alternative foraging strategies

    NASA Astrophysics Data System (ADS)

    Tinker, M. T.; Costa, D. P.; Estes, J. A.; Wieringa, N.

    2007-02-01

    The existence of individual prey specializations has been reported for an ever-growing number of taxa, and has important ramifications for our understanding of predator-prey dynamics. We use the California sea otter population as a case study to validate the use of archival time-depth data to detect and measure differences in foraging behaviour and diet. We collected observational foraging data from radio-tagged sea otters that had been equipped with Mk9 time depth recorders (TDRs, Wildlife Computers, Redmond, WA). After recapturing the study animals and retrieving the TDRs it was possible to compare the two data types, by matching individual dives from the TDR record with observational data and thus examining behavioural correlates of capture success and prey species. Individuals varied with respect to prey selection, aggregating into one of three distinct dietary specializations. A number of TDR-derived parameters, particularly dive depth and post-dive surface interval, differed predictably between specialist types. A combination of six dive parameters was particularly useful for discriminating between specialist types, and when incorporated into a multivariate cluster analysis, these six parameters resulted in classification of 13 adult female sea otters into three clusters that corresponded almost perfectly to the diet-based classification (1 out of 13 animals was misclassified). Thus based solely on quantifiable traits of time-depth data that have been collected over an appropriate period (in this case 1 year per animal), it was possible to assign female sea otters to diet type with >90% accuracy. TDR data can thus be used as a tool to measure the degree of individual specialization in sea otter populations, a conclusion that will likely apply to other diving marine vertebrates as well. Our ultimate goals must be both to understand the causes of individual specialization, and to incorporate such variation into models of population- and community-level food web dynamics.

  18. Longitudinal trends of HIV drug resistance in a large Canadian cohort, 1996-2016.

    PubMed

    Rocheleau, G; Brumme, C J; Shoveller, J; Lima, V D; Harrigan, P R

    2018-02-01

    We aim to identify long-term trends in HIV drug resistance before and after combined antiretroviral therapy (cART) initiation. IAS-USA (2015) mutations were identified in 23 271 HIV protease-reverse transcriptase sequences from 6543 treatment naïve adults in British Columbia. Participants who started cART between 1996 and 2014 were followed until April 2016. Equality of proportions test was used to compare the percentage of participants with acquired drug resistance (ADR) or transmitted drug resistance (TDR) in 1996, to those in 2014. Kaplan-Meier was used to estimate time to ADR in four drug resistance categories. Multivariable regression odds ratios (OR) of ADR for select clinical variables were determined by 5-year eras of cART initiation. The proportion of individuals with ADR declined from 39% (51/132) to 3% (8/322) in 1996-2014 (p <0.0001), while the proportion with TDR increased from 12% (16/132) to 18% (59/322) (p 0.14). The estimated proportions of individuals with ADR rose to 29% (NNRTI), 28% (3TC/FTC), 14% (other nRTI), and 7% (PI) after >16 years of therapy. After 5 years on therapy, participants initiating cART in 1996-2000 had 5.5-times more 3TC/FTC ADR, 5.3-times more other nRTI ADR, 4.7-times more NNRTI ADR, and 24-times more PI ADR than those starting in 2011-2014. The individuals with highest odds of developing ADR in 1996-2010 were adherent to regimens at levels between 60% and 80%, which shifted to <40% adherent in 2011-2014. HIV drug resistance transitioned from being primarily selected de-novo to being driven by TDR. Among those who started treatment in the past 5 years, ADR is rare and observed mostly in the lowest adherence strata. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Individual dietary specialization and dive behaviour in the California sea otter: Using archival time-depth data to detect alternative foraging strategies

    USGS Publications Warehouse

    Tinker, M.T.; Costa, D.P.; Estes, J.A.; Wieringa, N.

    2007-01-01

    The existence of individual prey specializations has been reported for an ever-growing number of taxa, and has important ramifications for our understanding of predator-prey dynamics. We use the California sea otter population as a case study to validate the use of archival time-depth data to detect and measure differences in foraging behaviour and diet. We collected observational foraging data from radio-tagged sea otters that had been equipped with Mk9 time depth recorders (TDRs, Wildlife Computers, Redmond, WA). After recapturing the study animals and retrieving the TDRs it was possible to compare the two data types, by matching individual dives from the TDR record with observational data and thus examining behavioural correlates of capture success and prey species. Individuals varied with respect to prey selection, aggregating into one of three distinct dietary specializations. A number of TDR-derived parameters, particularly dive depth and post-dive surface interval, differed predictably between specialist types. A combination of six dive parameters was particularly useful for discriminating between specialist types, and when incorporated into a multivariate cluster analysis, these six parameters resulted in classification of 13 adult female sea otters into three clusters that corresponded almost perfectly to the diet-based classification (1 out of 13 animals was misclassified). Thus based solely on quantifiable traits of time-depth data that have been collected over an appropriate period (in this case 1 year per animal), it was possible to assign female sea otters to diet type with >90% accuracy. TDR data can thus be used as a tool to measure the degree of individual specialization in sea otter populations, a conclusion that will likely apply to other diving marine vertebrates as well. Our ultimate goals must be both to understand the causes of individual specialization, and to incorporate such variation into models of population- and community-level food web dynamics. ?? 2007 Elsevier Ltd. All rights reserved.

  20. Predictive thermodynamics for ionic solids and liquids.

    PubMed

    Glasser, Leslie; Jenkins, H Donald Brooke

    2016-08-21

    The application of thermodynamics is simple, even if the theory may appear intimidating. We describe tools, developed over recent years, which make it easy to estimate often elusive thermodynamic parameter values, generally (but not exclusively) for ionic materials, both solid and liquid, as well as for their solid hydrates and solvates. The tools are termed volume-based thermodynamics (VBT) and thermodynamic difference rules (TDR), supplemented by the simple salt approximation (SSA) and single-ion values for volume, Vm, heat capacity, , entropy, , formation enthalpy, ΔfH°, and Gibbs formation energy, ΔfG°. These tools can be applied to provide values of thermodynamic and thermomechanical properties such as standard enthalpy of formation, ΔfH°, standard entropy, , heat capacity, Cp, Gibbs function of formation, ΔfG°, lattice potential energy, UPOT, isothermal expansion coefficient, α, and isothermal compressibility, β, and used to suggest the thermodynamic feasibility of reactions among condensed ionic phases. Because many of these methods yield results largely independent of crystal structure, they have been successfully extended to the important and developing class of ionic liquids as well as to new and hypothesised materials. Finally, these predictive methods are illustrated by application to K2SnCl6, for which known experimental results are available for comparison. A selection of applications of VBT and TDR is presented which have enabled input, usually in the form of thermodynamics, to be brought to bear on a range of topical problems. Perhaps the most significant advantage of VBT and TDR methods is their inherent simplicity in that they do not require a high level of computational expertise nor expensive high-performance computation tools - a spreadsheet will usually suffice - yet the techniques are extremely powerful and accessible to non-experts. The connection between formula unit volume, Vm, and standard thermodynamic parameters represents a major advance exploited by these techniques.

  1. Effect of neonatal gene therapy on lumbar spine disease in mucopolysaccharidosis VII dogs

    PubMed Central

    Smith, Lachlan J; Martin, John T; O'Donnell, Patricia; Wang, Ping; Elliott, Dawn M; Haskins, Mark E; Ponder, Katherine P

    2012-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient β-glucuronidase (GUSB) activity, which leads to accumulation of chondroitin, heparan, and dermatan sulfate glycosaminoglycans in various tissues including those of the spine. Associated spine disease can be due to abnormalities in the vertebrae, the intervertebral discs, or other spine tissues. The goal of this study was to determine if neonatal gene therapy could prevent lumbar spine disease in MPS VII dogs. MPS VII dogs were injected intravenously with a retroviral vector (RV) expressing canine GUSB at 2 to 3 days after birth, which resulted in transduction of hepatocytes that secreted GUSB into blood. Expression was stable for up to 11 years, and mean survival was increased from 0.4 years in untreated dogs to 6.1 years in treated dogs. Despite a profound positive clinical effect, 6-month-old RV-treated MPS VII dogs still had hypoplastic ventral epiphyses with reduced calcification in the lumbar spine, which resulted in a reduced stiffness and increased range of motion that was not improved relative to untreated MPS VII dogs. At six to 11 years of age, ventral vertebrae remained hypoplastic in RV-treated MPS VII dogs, and there was desiccation of the nucleus pulposus in some discs. Histochemical staining demonstrated that discs did not have detectable GUSB activity despite high serum GUSB activity, which is likely due to poor diffusion into this relatively avascular structure. Thus, neonatal gene therapy cannot prevent lumbar spine disease in MPS VII dogs, which predicts that enzyme replacement therapy (ERT) will similarly be relatively ineffective even if started at birth. PMID:22510705

  2. Competition among gene regulatory networks imposes order within the eye-antennal disc of Drosophila

    PubMed Central

    Weasner, Bonnie M.; Kumar, Justin P.

    2013-01-01

    The eye-antennal disc of Drosophila gives rise to numerous adult tissues, including the compound eyes, ocelli, antennae, maxillary palps and surrounding head capsule. The fate of each tissue is governed by the activity of unique gene regulatory networks (GRNs). The fate of the eye, for example, is controlled by a set of fourteen interlocking genes called the retinal determination (RD) network. Mutations within network members lead to replacement of the eyes with head capsule. Several studies have suggested that in these instances all retinal progenitor and precursor cells are eliminated via apoptosis and as a result the surrounding head capsule proliferates to compensate for retinal tissue loss. This model implies that the sole responsibility of the RD network is to promote the fate of the eye. We have re-analyzed eyes absent mutant discs and propose an alternative model. Our data suggests that in addition to promoting an eye fate the RD network simultaneously functions to actively repress GRNs that are responsible for directing antennal and head capsule fates. Compromising the RD network leads to the inappropriate expression of several head capsule selector genes such as cut, Lim1 and wingless. Instead of undergoing apoptosis, a population of mutant retinal progenitors and precursor cells adopt a head capsule fate. This transformation is accompanied by an adjustment of cell proliferation rates such that just enough head capsule is generated to produce an intact adult head. We propose that GRNs simultaneously promote primary fates, inhibit alternative fates and establish cell proliferation states. PMID:23222441

  3. Fluid mechanics of heart valves.

    PubMed

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  4. Growth factor effects on costal chondrocytes for tissue engineering fibrocartilage

    PubMed Central

    Johns, D.E.; Athanasiou, K.A.

    2010-01-01

    Tissue engineered fibrocartilage could become a feasible option for replacing tissues like the knee meniscus or temporomandibular joint disc. This study employed five growth factors insulin-like growth factor-I, transforming growth factor-β1, epidermal growth factor, platelet-derived growth factor-BB, and basic fibroblast growth factor in a scaffoldless approach with costal chondrocytes, attempting to improve biochemical and mechanical properties of engineered constructs. Samples were quantitatively assessed for total collagen, glycosaminoglycans, collagen type I, collagen type II, cells, compressive properties, and tensile properties at two time points. Most treated constructs were worse than the no growth factor control, suggesting a detrimental effect, but the IGF treatment tended to improve the constructs. Additionally, the 6wk time point was consistently better than 3wks, with total collagen, glycosaminoglycans, and aggregate modulus doubling during this time. Further optimization of the time in culture and exogenous stimuli will be important in making a more functional replacement tissue. PMID:18597118

  5. Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.

    PubMed

    Grupp, Thomas M; Yue, James J; Garcia, Rolando; Basson, Janet; Schwiesau, Jens; Fritz, Bernhard; Blömer, Wilhelm

    2009-01-01

    Wear simulation is an essential pre-clinical method to predict the mid- and long-term clinical wear behavior of newly introduced devices for total disc arthroplasty. The main requirement of a suitable method for spinal wear simulation has to be the ability to distinguish between design concepts and allow for a direct comparison of predicate devices. The objective of our study was to investigate the influence of loading and kinematic patterns based on two different protocols for spinal wear simulation (ISO/FDIS 18192-1 (2006) and ASTM F2423-05). In vitro wear simulation was performed with six activ L lumbar artificial disc devices (Aesculap Tuttlingen, Germany). The applied kinematic pattern of movement was multidirectional for ISO (elliptic track) and unidirectional with a curvilinear shape for ASTM. Testing was done for 10 million cycles in the ISO loading mode and afterwards with the same specimens for 5 million cycles according to the ASTM protocol with a customized six-station servohydraulic spinal wear simulator (EndoLab Thansau, Germany). Gravimetrical and geometrical wear assessment, a slide track analysis correlated to an optical surface characterization, and an estimation of particle size and morphology were performed. The gravimetric wear rate for the first 10 million cycles was ISO(initial) = 2.7 +/- 0.3 mg/million cycles. During the ASTM test period (10-15 million cycles) a gravimetric wear rate of 0.14 +/- 0.06 mg/million cycles was estimated. The wear rates between the ISO and ASTM driven simulations differ substantially (approximately 20-fold) and statistical analysis demonstrates a significant difference (p < 0.001) between the test groups. The main explanation of divergency between ISO and ASTM driven wear simulations is the multidirectional pattern of movement described in the ISO document resulting in a cross-shear stress on the polyethylene material. Due to previous retrieval observations, it seems to be very unlikely that a lumbar artificial disc is loaded with a linear wear path.Testing according to ASTM F2423-05 with pure unidirectional motion does not reflect the kinematics of TDA patients' daily activities. Based on our findings it seems to be more reliable to predict the clinical wear behavior of an artificial disc replacement using the ISO/FDIS 18192-1 method.

  6. Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation

    PubMed Central

    Yue, James J.; Garcia, Rolando; Basson, Janet; Schwiesau, Jens; Fritz, Bernhard; Blömer, Wilhelm

    2008-01-01

    Wear simulation is an essential pre-clinical method to predict the mid- and long-term clinical wear behavior of newly introduced devices for total disc arthroplasty. The main requirement of a suitable method for spinal wear simulation has to be the ability to distinguish between design concepts and allow for a direct comparison of predicate devices. The objective of our study was to investigate the influence of loading and kinematic patterns based on two different protocols for spinal wear simulation (ISO/FDIS 18192-1 (2006) and ASTM F2423-05). In vitro wear simulation was performed with six activ® L lumbar artificial disc devices (Aesculap Tuttlingen, Germany). The applied kinematic pattern of movement was multidirectional for ISO (elliptic track) and unidirectional with a curvilinear shape for ASTM. Testing was done for 10 million cycles in the ISO loading mode and afterwards with the same specimens for 5 million cycles according to the ASTM protocol with a customized six-station servohydraulic spinal wear simulator (EndoLab Thansau, Germany). Gravimetrical and geometrical wear assessment, a slide track analysis correlated to an optical surface characterization, and an estimation of particle size and morphology were performed. The gravimetric wear rate for the first 10 million cycles was ISOinitial = 2.7 ± 0.3 mg/million cycles. During the ASTM test period (10–15 million cycles) a gravimetric wear rate of 0.14 ± 0.06 mg/million cycles was estimated. The wear rates between the ISO and ASTM driven simulations differ substantially (approximately 20-fold) and statistical analysis demonstrates a significant difference (p < 0.001) between the test groups. The main explanation of divergency between ISO and ASTM driven wear simulations is the multidirectional pattern of movement described in the ISO document resulting in a cross-shear stress on the polyethylene material. Due to previous retrieval observations, it seems to be very unlikely that a lumbar artificial disc is loaded with a linear wear path.Testing according to ASTM F2423-05 with pure unidirectional motion does not reflect the kinematics of TDA patients‘ daily activities. Based on our findings it seems to be more reliable to predict the clinical wear behavior of an artificial disc replacement using the ISO/FDIS 18192-1 method. PMID:19050942

  7. Adjacent-level arthroplasty following cervical fusion.

    PubMed

    Rajakumar, Deshpande V; Hari, Akshay; Krishna, Murali; Konar, Subhas; Sharma, Ankit

    2017-02-01

    OBJECTIVE Adjacent-level disc degeneration following cervical fusion has been well reported. This condition poses a major treatment dilemma when it becomes symptomatic. The potential application of cervical arthroplasty to preserve motion in the affected segment is not well documented, with few studies in the literature. The authors present their initial experience of analyzing clinical and radiological results in such patients who were treated with arthroplasty for new or persistent arm and/or neck symptoms related to neural compression due to adjacent-segment disease after anterior cervical discectomy and fusion (ACDF). METHODS During a 5-year period, 11 patients who had undergone ACDF anterior cervical discectomy and fusion (ACDF) and subsequently developed recurrent neck or arm pain related to adjacent-level cervical disc disease were treated with cervical arthroplasty at the authors' institution. A total of 15 devices were implanted (range of treated levels per patient: 1-3). Clinical evaluation was performed both before and after surgery, using a visual analog scale (VAS) for pain and the Neck Disability Index (NDI). Radiological outcomes were analyzed using pre- and postoperative flexion/extension lateral radiographs measuring Cobb angle (overall C2-7 sagittal alignment), functional spinal unit (FSU) angle, and range of motion (ROM). RESULTS There were no major perioperative complications or device-related failures. Statistically significant results, obtained in all cases, were reflected by an improvement in VAS scores for neck/arm pain and NDI scores for neck pain. Radiologically, statistically significant increases in the overall lordosis (as measured by Cobb angle) and ROM at the treated disc level were observed. Three patients were lost to follow-up within the first year after arthroplasty. In the remaining 8 cases, the duration of follow-up ranged from 1 to 3 years. None of these 8 patients required surgery for the same vertebral level during the follow-up period. CONCLUSIONS Artificial cervical disc replacement in patients who have previously undergone cervical fusion surgery appears to be safe, with encouraging early clinical results based on this small case series, but more data from larger numbers of patients with long-term follow-up are needed. Arthroplasty may provide an additional tool for the management of post-fusion adjacent-level cervical disc disease in carefully selected patients.

  8. Robust spatialization of soil water content at the scale of an agricultural field using geophysical and geostatistical methods

    NASA Astrophysics Data System (ADS)

    Henine, Hocine; Tournebize, Julien; Laurent, Gourdol; Christophe, Hissler; Cournede, Paul-Henry; Clement, Remi

    2017-04-01

    Research on the Critical Zone (CZ) is a prerequisite for undertaking issues related to ecosystemic services that human societies rely on (nutrient cycles, water supply and quality). However, while the upper part of CZ (vegetation, soil, surface water) is readily accessible, knowledge of the subsurface remains limited, due to the point-scale character of conventional direct observations. While the potential for geophysical methods to overcome this limitation is recognized, the translation of the geophysical information into physical properties or states of interest remains a challenge (e.g. the translation of soil electrical resistivity into soil water content). In this study, we propose a geostatistical framework using the Bayesian Maximum Entropy (BME) approach to assimilate geophysical and point-scale data. We especially focus on the prediction of the spatial distribution of soil water content using (1) TDR point-scale measurements of soil water content, which are considered as accurate data, and (2) soil water content data derived from electrical resistivity measurements, which are uncertain data but spatially dense. We used a synthetic dataset obtained with a vertical 2D domain to evaluate the performance of this geostatistical approach. Spatio-temporal simulations of soil water content were carried out using Hydrus-software for different scenarios: homogeneous or heterogeneous hydraulic conductivity distribution, and continuous or punctual infiltration pattern. From the simulations of soil water content, conceptual soil resistivity models were built using a forward modeling approach and point sampling of water content values, vertically ranged, were done. These two datasets are similar to field measurements of soil electrical resistivity (using electrical resistivity tomography, ERT) and soil water content (using TDR probes) obtained at the Boissy-le-Chatel site, in Orgeval catchment (East of Paris, France). We then integrated them into a specialization framework to predict the soil water content distribution and the results were compared to initial simulations (Hydrus results). We obtained more reliable water content specialization models when using the BME method. The presented approach integrates ERT and TDR measurements, and results demonstrate that its use significantly improves the spatial distribution of water content estimations. The approach will be applied to the experimental dataset collected at the Boissy le Châtel site where ERT data were collected daily during one hydrological year, using Syscal pro 48 electrodes (with a financial support of Equipex-Critex) and 10 TDR probes were used to monitor water content variation. Hourly hydrological survey (tile drainage discharge, precipitation, evapotranspiration variables and water table depth) were conducted at the same site. Data analysis and the application of geostatistical framework on the experimental dataset of 2015-2016 show satisfactory results and are reliable with the hydrological behavior of the study site.

  9. Clinical and radiographic analysis of an artificial cervical disc: 7-year follow-up from the Prestige prospective randomized controlled clinical trial: Clinical article.

    PubMed

    Burkus, J Kenneth; Traynelis, Vincent C; Haid, Regis W; Mummaneni, Praveen V

    2014-10-01

    The authors assess the long-term safety and efficacy of cervical disc replacement with the Prestige Cervical Disc in a prospective, randomized, multicenter trial at 7 years of follow-up. At 31 investigational sites, 541 patients with single-level cervical disc disease with radiculopathy were randomized to 1 of 2 treatment groups: 276 investigational group patients underwent anterior cervical discectomy and arthroplasty with the Prestige disc, and 265 control group patients underwent anterior cervical discectomy and fusion. Clinical outcomes included Neck Disability Index, the 36-Item Short-Form Health Survey, and neck and arm pain scores. Radiographs were assessed for angle of motion and fusion. Clinical and radiographic outcomes were evaluated preoperatively, intraoperatively, and at 1.5, 3, 6, 12, 24, 36, 60, and 84 months. Of the 541 patients treated, 395 patients (73%; 212 investigational and 183 control patients) completed 7 years of clinical follow-up. Significant improvements achieved by 1.5 months in both groups were sustained at 7 years. In the investigational group, mean Neck Disability Index improvements from preoperative scores were 38.2 and 37.5 at 60 and 84 months, respectively. In the control group, the corresponding means were 33.8 and 31.9. The differences between the investigational and control groups at the 60-month and 84-month periods were significant (p = 0.014 and 0.002, respectively). The overall rates of maintenance or improvement in neurological status in the investigational group were significantly higher: 92.2% and 88.2% at 60 months and 84 months, respectively, compared with 85.7% and 79.7% in the control group (p = 0.017 and 0.011, respectively). At 84 months, the percentage of working patients in the investigational group was 73.9%, and in the control group, 73.1%. Postoperatively, the implant effectively maintained average angular motion of 6.67° at 60 months and 6.75° at 84 months. Cumulative rates for surgery at the index level were lower (p < 0.001) in the investigational group (11 [4.8%] of 276) when compared with the control group (29 [13.7%] of 265) (based on life-table method), and there were statistical differences between the investigational and control groups with specific regard to the rate of subsequent revision and supplemental fixation surgical procedures. Rates for additional surgical procedures that involved adjacent levels were lower in the investigational group than in the control group (11 [4.6%] of 276 vs. 24 [11.9%] of 265, respectively). Cervical disc arthroplasty has the potential for preserving motion at the operated level while providing biomechanical stability and global neck mobility and may result in a reduction in adjacent-segment degeneration. The Prestige Cervical Disc maintains improved clinical outcomes and segmental motion after implantation at 7-year follow-up. Clinical trial registration no. NCT00642876 ( ClinicalTrials.gov ).

  10. Comparison of animal discs used in disc research to human lumbar disc: torsion mechanics and collagen content.

    PubMed

    Showalter, Brent L; Beckstein, Jesse C; Martin, John T; Beattie, Elizabeth E; Espinoza Orías, Alejandro A; Schaer, Thomas P; Vresilovic, Edward J; Elliott, Dawn M

    2012-07-01

    Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these with the human disc. To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar discs, and cow, rat, and mouse caudal discs. Collagen content was measured and normalized by dry weight for the same discs except the rat and the mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human discs. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Disc torsion mechanics are comparable with human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented are useful for selecting and interpreting results for animal disc models. Structural organization of the fiber angle may explain the differences that were noted between species after geometric normalization.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, J E; Smith, J T; Mathis, M V

    Based on the limited measurements and the attempts to activate the high voltage power supply, the Source Range Monitor which includes NI-AMP-2 is not operating. Since there appears to be an excessive load on the high voltage, it appears that either the detector or cable is defective. However, TDR measurements did not indicate a significant problem with the cable using low level test signals.

  12. Information management system: A summary discussion. [for use in the space shuttle sortie, modular space station and TDR satellite

    NASA Technical Reports Server (NTRS)

    Sayers, R. S.

    1972-01-01

    An information management system is proposed for use in the space shuttle sortie, the modular space station, the tracking data relay satellite and associated ground support systems. Several different information management functions, including data acquisition, transfer, storage, processing, control and display are integrated in the system.

  13. [Research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration].

    PubMed

    Liang, Hang; Deng, Xiangyu; Shao, Zengwu

    2017-10-01

    To summarize the research progress of intervertebral disc endogenous stem cells for intervertebral disc regeneration and deduce the therapeutic potential of endogenous repair for intervertebral disc degeneration. The original articles about intervertebral disc endogenous stem cells for intervertebral disc regeneration were extensively reviewed; the reparative potential in vivo and the extraction and identification in vitro of intervertebral disc endogenous stem cells were analyzed; the prospect of endogenous stem cells for intervertebral disc regeneration was predicted. Stem cell niche present in the intervertebral discs, from which stem cells migrate to injured tissues and contribute to tissues regeneration under certain specific microenvironment. Moreover, the migration of stem cells is regulated by chemokines system. Tissue specific progenitor cells have been identified and successfully extracted and isolated. The findings provide the basis for biological therapy of intervertebral disc endogenous stem cells. Intervertebral disc endogenous stem cells play a crucial role in intervertebral disc regeneration. Therapeutic strategy of intervertebral disc endogenous stem cells is proven to be a promising biological approach for intervertebral disc regeneration.

  14. Comparison of Animal Discs Used in Disc Research to Human Lumbar Disc: Torsion Mechanics and Collagen Content

    PubMed Central

    Showalter, Brent L.; Beckstein, Jesse C.; Martin, John T.; Beattie, Elizabeth E.; Orías, Alejandro A. Espinoza; Schaer, Thomas P.; Vresilovic, Edward J.; Elliott, Dawn M.

    2012-01-01

    Study Design Experimental measurement and normalization of in vitro disc torsion mechanics and collagen content for several animal species used in intervertebral disc research and comparing these to the human disc. Objective To aid in the selection of appropriate animal models for disc research by measuring torsional mechanical properties and collagen content. Summary of Background Data There is lack of data and variability in testing protocols for comparing animal and human disc torsion mechanics and collagen content. Methods Intervertebral disc torsion mechanics were measured and normalized by disc height and polar moment of inertia for 11 disc types in 8 mammalian species: the calf, pig, baboon, goat, sheep, rabbit, rat, and mouse lumbar, and cow, rat, and mouse caudal. Collagen content was measured and normalized by dry weight for the same discs except the rat and mouse. Collagen fiber stretch in torsion was calculated using an analytical model. Results Measured torsion parameters varied by several orders of magnitude across the different species. After geometric normalization, only the sheep and pig discs were statistically different from human. Fiber stretch was found to be highly dependent on the assumed initial fiber angle. The collagen content of the discs was similar, especially in the outer annulus where only the calf and goat discs were statistically different from human. Disc collagen content did not correlate with torsion mechanics. Conclusion Disc torsion mechanics are comparable to human lumbar discs in 9 of 11 disc types after normalization by geometry. The normalized torsion mechanics and collagen content of the multiple animal discs presented is useful for selecting and interpreting results for animal models of the disc. Structural composition of the disc, such as initial fiber angle, may explain the differences that were noted between species after geometric normalization. PMID:22333953

  15. Electromagnetic versus Lense-Thirring alignment of black hole accretion discs

    NASA Astrophysics Data System (ADS)

    Polko, Peter; McKinney, Jonathan C.

    2017-01-01

    Accretion discs and black holes (BHs) have angular momenta that are generally misaligned, which can lead to warped discs and bends in any jets produced. We examine whether a disc that is misaligned at large radii can be aligned more efficiently by the torque of a Blandford-Znajek (BZ) jet than by Lense-Thirring (LT) precession. To obtain a strong result, we will assume that these torques maximally align the disc, rather than cause precession, or disc tearing. We consider several disc states that include radiatively inefficient thick discs, radiatively efficient thin discs, and super-Eddington accretion discs. The magnetic field strength of the BZ jet is chosen as either from standard equipartition arguments or from magnetically arrested disc (MAD) simulations. We show that standard thin accretion discs can reach spin-disc alignment out to large radii long before LT would play a role, due to the slow infall time that gives even a weak BZ jet time to align the disc. We show that geometrically thick radiatively inefficient discs and super-Eddington discs in the MAD state reach spin-disc alignment near the BH when density profiles are shallow as in magnetohydrodynamical simulations, while the BZ jet aligns discs with steep density profiles (as in advection-dominated accretion flows) out to larger radii. Our results imply that the BZ jet torque should affect the cosmological evolution of BH spin magnitude and direction, spin measurements in active galactic nuclei and X-ray binaries, and the interpretations for Event Horizon Telescope observations of discs or jets in strong-field gravity regimes.

  16. U.S. EPA, Pesticide Product Label, RANGE CATTLE LIVESTOCK & SHEEP DIP CONCENTRATE, 03/02/1984

    EPA Pesticide Factsheets

    2011-04-21

    ... CiSDc~e of in a ~an,tdr.f ~arCf1:1 )r lnc~'1erd~~cn, crt 1~ d~~owe~:'/ sta~e ~nc :oca1 aLJt~ori~ies. ~~ :urp~~c. :; Jur··~~, s:a, :~~ ~f ;~~~e. ...

  17. 12 CFR Appendix C to Part 741 - Interpretive Ruling and Policy Statement on Loan Workouts, Nonaccrual Policy, and Regulatory...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... such circumstances exist, and as long as they exist—consistent with GAAP the Cost Recovery Method of... loans (herein after referred to as TDR or TDRs). 1 Terms defined in the Glossary will be italicized on... “workouts” for further descriptions of each term. Borrower retention programs or new loans are not...

  18. Stacked microbial desalination cells to enhance water desalination efficiency.

    PubMed

    Chen, Xi; Xia, Xue; Liang, Peng; Cao, Xiaoxin; Sun, Haotian; Huang, Xia

    2011-03-15

    Microbial desalination cell (MDC) is a new method to obtain clean water from brackish water using electricity generated from organic matters by exoelectrogenic bacteria. Anions and cations, derived from salt solution filled in the desalination chamber between the anode and cathode, move to the anode and cathode chambers under the force of electrical field, respectively. On the basis of the primitive single-desalination-chambered MDC, stacked microbial desalination cells (SMDCs) were developed in order to promote the desalination rate in the present study. The effects of desalination chamber number and external resistance were investigated. Results showed that a remarkable increase in the total desalination rate (TDR) could be obtained by means of increasing the desalination cell number and reducing the external resistance, which caused the charge transfer efficiency increased since the SMDCs enabled more pairs of ions separated while one electron passed through the external circuit. The maximum TDR of 0.0252 g/h was obtained using a two-desalination-chambered SMDC with an external resistance of 10 Ω, which was 1.4 times that of single-desalination-chambered MDC. SMDCs proved to be an effective approach to increase the total water desalination rate if provided a proper desalination chamber number and external resistance.

  19. Carotenoid distribution in wild Japanese tree frogs (Hyla japonica) exposed to ionizing radiation in Fukushima.

    PubMed

    Giraudeau, Mathieu; Bonzom, Jean-Marc; Ducatez, Simon; Beaugelin-Seiller, Karine; Deviche, Pierre; Lengagne, Thierry; Cavalie, Isabelle; Camilleri, Virginie; Adam-Guillermin, Christelle; McGraw, Kevin J

    2018-05-09

    The nuclear accident in the Fukushima prefecture released a large amount of artificial radionuclides that might have short- and long-term biological effects on wildlife. Ionizing radiation can be a harmful source of reactive oxygen species, and previous studies have already shown reduced fitness effects in exposed animals in Chernobyl. Due to their potential health benefits, carotenoid pigments might be used by animals to limit detrimental effects of ionizing radiation exposure. Here, we examined concentrations of carotenoids in blood (i.e. a snapshot of levels in circulation), liver (endogenous carotenoid reserves), and the vocal sac skin (sexual signal) in relation to the total radiation dose rates absorbed by individual (TDR from 0.2 to 34 µGy/h) Japanese tree frogs (Hyla japonica). We found high within-site variability of TDRs, but no significant effects of the TDR on tissue carotenoid levels, suggesting that carotenoid distribution in amphibians might be less sensitive to ionizing radiation exposure than in other organisms or that the potential deleterious effects of radiation exposure might be less significant or more difficult to detect in Fukushima than in Chernobyl due to, among other things, differences in the abundance and mixture of each radionuclide.

  20. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adolphsen, Chris

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  1. The International Linear Collider Technical Design Report - Volume 1: Executive Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behnke, Ties; Brau, James E.; Foster, Brian

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  2. The International Linear Collider Technical Design Report - Volume 3.I: Accelerator \\& in the Technical Design Phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adolphsen, Chris

    2013-06-26

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carriedmore » out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.« less

  3. Kinematic Evaluation of Association between Disc Bulge Migration, Lumbar Segmental Mobility, and Disc Degeneration in the Lumbar Spine Using Positional Magnetic Resonance Imaging

    PubMed Central

    Hu, Jonathan K.; Morishita, Yuichiro; Montgomery, Scott R.; Hymanson, Henry; Taghavi, Cyrus E.; Do, Duc; Wang, Jeff C.

    2011-01-01

    Degenerative disc disease and disc bulge in the lumbar spine are common sources of lower back pain. Little is known regarding disc bulge migration and lumbar segmental mobility as the lumbar spine moves from flexion to extension. In this study, 329 symptomatic (low back pain with or without neurological symptoms) patients with an average age of 43.5 years with varying degrees of disc degeneration were examined to characterize the kinematics of the lumbar intervertebral discs through flexion, neutral, and extension weight-bearing positions. In this population, disc bulge migration associated with dynamic motion of the lumbar spine significantly increased with increased grade of disk degeneration. Although no obvious trends relating the migration of disc bulge and angular segmental mobility were seen, translational segmental mobility tended to increase with disc bulge migration in all of the degenerative disc states. It appears that many factors, both static (intervertebral disc degeneration or disc height) and dynamic (lumbar segmental mobility), affect the mechanisms of lumbar disc bulge migration. PMID:24353937

  4. Intervertebral disc-derived stem cells: implications for regenerative medicine and neural repair.

    PubMed

    Erwin, W Mark; Islam, Diana; Eftekarpour, Eftekhar; Inman, Robert D; Karim, Muhammad Zia; Fehlings, Michael G

    2013-02-01

    An in vitro and in vivo evaluation of intervertebral disc (IVD)-derived stem/progenitor cells. To determine the chondrogenic, adipogenic, osteogenic, and neurogenic differentiation capacity of disc-derived stem/progenitor cells in vitro and neurogenic differentiation in vivo. Tissue repair strategies require a source of appropriate cells that could be used to replace dead or damaged cells and tissues such as stem cells. Here we examined the potential use of IVD-derived stem cells in regenerative medicine approaches and neural repair. Nonchondrodystrophic canine IVD nucleus pulposus (NP) cells were used to generate stem/progenitor cells (NP progenitor cells [NPPCs]) and the NPPCs were differentiated in vitro into chondrogenic, adipogenic, and neurogenic lineages and in vivo into the neurogenic lineage. NPPCs were compared with bone marrow-derived mesenchymal (stromal) stem cells in terms of the expression of stemness genes. The expression of the neural crest marker protein 0 and the Brachyury gene were evaluated in NP cells and NPPCs. NPPCs contain stem/progenitor cells and express "stemness" genes such as Sox2, Oct3/4, Nanog, CD133, Nestin, and neural cell adhesion molecule but differ from mesenchymal (stromal) stem cells in the higher expression of the Nanog gene by NPPCs. NPPCs do not express protein 0 or the Brachyury gene both of which are expressed by the totality of IVD NP cells. The percentage of NPPCs within the IVD is 1% of the total as derived by colony-forming assay. NPPCs are capable of differentiating along chondrogenic, adipogenic, and neurogenic lineages in vitro and into oligodendrocyte, neuron, and astroglial specific precursor cells in vivo within the compact myelin-deficient shiverer mouse. We propose that the IVD NP represents a regenerative niche suggesting that the IVD could represent a readily accessible source of precursor cells for neural repair and regeneration.

  5. Biosignatures in modern sulfates: texture, composition and depositional environments of gypsum deposits at Guerrero Negro, Baja, Mexico

    NASA Astrophysics Data System (ADS)

    Vogel, M. B.; Des Marais, D. J.; Jahnke, L. L.; Turk, K.; Kubo, M.

    2007-12-01

    Gypsum (CaSO4·H2O) is an important phase in biogeochemistry and sedimentology as a mineral sink for sulfur, a paleoclimatic indicator, and an endolithic niche for phototrophic and chemotrophic bacteria. Sulfate deposits are also important targets of exploration for evidence of habitable environments and life on Mars. Gypsum deposits from a range of sedimentary environments at the Guerrero Negro crystallizer ponds and sabkha settings were investigated for microscale structure and composition to differentiate fabrics formed under microbial influence from those formed under abiogenic conditions. Sub-sedimentary gypsum forms in sabkha environments as mm to cm scale selenite discs (termed bird beak gypsum; Warren, 2006) and selenite disc aggregates. Selenite discs and other sub-sedimentary gypsum are characterized by a sinuous axial microtexture and poikilitically enclosed detrital particles. Sub-aqueous gypsum forms as cements, granules (termed gypsooids), and massive botryoidal crusts that line the sediment water interface and margins of managed crystallizer ponds and natural anchialine pools. Sub-aqueous gypsum exhibits a wide range of textures and mineral/biofilm associations that include amorphous to euhedral, tabular, needle and lensoidal morphologies. Elemental sulfur forms rinds on prismatic, growth aligned gypsum twins and reticulate magnesian carbonate is interspersed with both twinned crystals and rosette aggregates in stratified sub-aqueous environments. Intracrystalline biofilms and cell material was observed in association with nearly all sub-aqueous morphologies but only scarce evidence has been found for intercrystalline microbial communities. Columnar microbial communities living in anchialine pools were found to host precipitation of mm scale gypsum granules in their EPS matrix. Fine scale gypsum textures are unlikely to persist through diagenetic alteration, but understanding their primary associations with sulfur and carbonates is necessary for interpreting sulfates or their replacement phases in the ancient record.

  6. Survivorship and clinical outcomes after multi-level anterior lumbar reconstruction with stand-alone anterior lumbar interbody fusion or hybrid construct.

    PubMed

    Chen, Benjamin; Akpolat, Yusuf T; Williams, Paul; Bergey, Darren; Cheng, Wayne K

    2016-06-01

    In multilevel disc disease, there is still uncertainty regarding whether multiple total disc replacement is more effective and safer than fusion. Our objective was to measure and compare the clinical outcome of multilevel hybrid constructs with stand-alone anterior lumbar interbody fusion (ALIF) using a retrospective analysis. Sixty-four patients with chronic low back pain determined to be from two or three-level degenerative disc disease were included. Thirty-three patients were treated with hybrid fusion and 31 with ALIF. Several parameters were retrospectively reviewed, including blood loss, operation time, hospital stay, Visual Analog Scale (VAS) score, Oswestry Disability Index (ODI), and survivorship without the need for revision surgery. Telephone follow-ups were conducted to ascertain survivorship, clinical outcomes (VAS, ODI) and patient satisfaction. Operation time was longer in the hybrid group (p=0.021). The hybrid group showed a significant improvement in VAS and ODI with 52.2% and 50.0% improvement versus 28.3% and 25.5% in the ALIF group (p<0.05). At the telephone follow-up for patient satisfaction, 95.7% (n=22) of the hybrid group were satisfied and 95.2% (n=21) of the ALIF group were satisfied. Seventy-four percent (n=17) in the hybrid group and 85.7% (n=18) in the ALIF group would choose to do the initial surgery again. Kaplan-Meier analysis showed 80.5% survivorship for hybrids and 75.9% for ALIF at 5years. With our clinical outcomes in VAS and ODI scores, these results, when taken together, indicate that hybrid fusion is a valid and viable alternative to ALIF fusion, with at least equal if not better clinical outcomes in terms of survivorship, back pain, and disability scores. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Three-dimensional development of tensile pre-strained annulus fibrosus cells for tissue regeneration: An in-vitro study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chuah, Yon Jin; Lee, Wu Chean; Wong, Hee Kit

    Prior research has investigated the immediate response after application of tensile strain on annulus fibrosus (AF) cells for the past decade. Although mechanical strain can produce either catabolic or anabolic consequences to the cell monolayer, little is known on how to translate these findings into further tissue engineering applications. Till to date, the application and effect of tensile pre-strained cells to construct a three-dimensional (3D) AF tissue remains unknown. This study aims to investigate the effect of tensile pre-strained exposure of 1 to 24 h on the development of AF pellet culture for 3 weeks. Equibiaxial cyclic tensile strain wasmore » applied on AF monolayer cells over a period of 24 h, which was subsequently developed into a cell pellet. Investigation on cellular proliferation, phenotypic gene expression, and histological changes revealed that tensile pre-strain for 24 h had significant and lasting effect on the AF tissue development, with enhanced cell proliferation, and up-regulation of collagen type I, II, and aggrecan expression. Our results demonstrated the regenerative ability of AF cell pellets subjected to 24 h tensile pre-straining. Knowledge on the effects of tensile pre-strain exposure is necessary to optimize AF development for tissue reconstruction. Moreover, the tensile pre-strained cells may further be utilized in either cell therapy to treat mild disc degeneration disease, or the development of a disc construct for total disc replacement. - Highlights: • Establishment of tensile pre-strained cell line population for annulus development. • Tensile strain limits collagen gene expression declination in monolayer culture. • Tensile pre-strained cells up-regulate their matrix protein in 3D pellet culture.« less

  8. Effect of five-membered ring and heteroatom substitution on charge transport properties of perylene discotic derivatives: A theoretical approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Navarro, Amparo, E-mail: anavarro@ujaen.es; Fernández-Liencres, M. Paz; Peña-Ruiz, Tomás

    2016-08-07

    Density functional theory calculations were carried out to investigate the evolvement of charge transport properties of a set of new discotic systems as a function of ring and heteroatom (B, Si, S, and Se) substitution on the basic structure of perylene. The replacement of six-membered rings by five-membered rings in the reference compound has shown a prominent effect on the electron reorganization energy that decreases ∼0.2 eV from perylene to the new carbon five-membered ring derivative. Heteroatom substitution with boron also revealed to lower the LUMO energy level and increase the electron affinity, therefore lowering the electron injection barrier comparedmore » to perylene. Since the rate of the charge transfer between two molecules in columnar discotic systems is strongly dependent on the orientation of the stacked cores, the total energy and transfer integral of a dimer as a disc is rotated with respect to the other along the stacking axis have been predicted. Aimed at obtaining a more realistic approach to the bulk structure, the molecular geometry of clusters made up of five discs was fully optimized, and charge transfer rate and mobilities were estimated for charge transport along a one dimensional pathway. Heteroatom substitution with selenium yields electron transfer integral values ∼0.3 eV with a relative disc orientation of 25°, which is the preferred angle according to the dimer energy profile. All the results indicate that the tetraselenium-substituted derivative, not synthetized so far, could be a promising candidate among those studied in this work for the fabrication of n-type semiconductors based on columnar discotic liquid crystals materials.« less

  9. Silk-based multilayered angle-ply annulus fibrosus construct to recapitulate form and function of the intervertebral disc.

    PubMed

    Bhunia, Bibhas K; Kaplan, David L; Mandal, Biman B

    2018-01-16

    Recapitulation of the form and function of complex tissue organization using appropriate biomaterials impacts success in tissue engineering endeavors. The annulus fibrosus (AF) represents a complex, multilamellar, hierarchical structure consisting of collagen, proteoglycans, and elastic fibers. To mimic the intricacy of AF anatomy, a silk protein-based multilayered, disc-like angle-ply construct was fabricated, consisting of concentric layers of lamellar sheets. Scanning electron microscopy and fluorescence image analysis revealed cross-aligned and lamellar characteristics of the construct, mimicking the native hierarchical architecture of the AF. Induction of secondary structure in the silk constructs was confirmed by infrared spectroscopy and X-ray diffraction. The constructs showed a compressive modulus of 499.18 ± 86.45 kPa. Constructs seeded with porcine AF cells and human mesenchymal stem cells (hMSCs) showed ∼2.2-fold and ∼1.7-fold increases in proliferation on day 14, respectively, compared with initial seeding. Biochemical analysis, histology, and immunohistochemistry results showed the deposition of AF-specific extracellular matrix (sulfated glycosaminoglycan and collagen type I), indicating a favorable environment for both cell types, which was further validated by the expression of AF tissue-specific genes. The constructs seeded with porcine AF cells showed ∼11-, ∼5.1-, and ∼6.7-fold increases in col I α 1 , sox 9, and aggrecan genes, respectively. The differentiation of hMSCs to AF-like tissue was evident from the enhanced expression of the AF-specific genes. Overall, the constructs supported cell proliferation, differentiation, and ECM deposition resulting in AF-like tissue features based on ECM deposition and morphology, indicating potential for future studies related to intervertebral disc replacement therapy.

  10. Effect of five-membered ring and heteroatom substitution on charge transport properties of perylene discotic derivatives: A theoretical approach.

    PubMed

    Navarro, Amparo; Fernández-Liencres, M Paz; Peña-Ruiz, Tomás; García, Gregorio; Granadino-Roldán, José M; Fernández-Gómez, Manuel

    2016-08-07

    Density functional theory calculations were carried out to investigate the evolvement of charge transport properties of a set of new discotic systems as a function of ring and heteroatom (B, Si, S, and Se) substitution on the basic structure of perylene. The replacement of six-membered rings by five-membered rings in the reference compound has shown a prominent effect on the electron reorganization energy that decreases ∼0.2 eV from perylene to the new carbon five-membered ring derivative. Heteroatom substitution with boron also revealed to lower the LUMO energy level and increase the electron affinity, therefore lowering the electron injection barrier compared to perylene. Since the rate of the charge transfer between two molecules in columnar discotic systems is strongly dependent on the orientation of the stacked cores, the total energy and transfer integral of a dimer as a disc is rotated with respect to the other along the stacking axis have been predicted. Aimed at obtaining a more realistic approach to the bulk structure, the molecular geometry of clusters made up of five discs was fully optimized, and charge transfer rate and mobilities were estimated for charge transport along a one dimensional pathway. Heteroatom substitution with selenium yields electron transfer integral values ∼0.3 eV with a relative disc orientation of 25°, which is the preferred angle according to the dimer energy profile. All the results indicate that the tetraselenium-substituted derivative, not synthetized so far, could be a promising candidate among those studied in this work for the fabrication of n-type semiconductors based on columnar discotic liquid crystals materials.

  11. Imaginal Disc Abnormalities in Lethal Mutants of Drosophila

    PubMed Central

    Shearn, Allen; Rice, Thomas; Garen, Alan; Gehring, Walter

    1971-01-01

    Late lethal mutants of Drosophila melanogaster, dying after the larval stage of development, were isolated. The homozygous mutant larvae were examined for abnormal imaginal disc morphology, and the discs were injected into normal larval hosts to test their capacities to differentiate into adult structures. In about half of the mutants analyzed, disc abnormalities were found. Included among the abnormalities were missing discs, small discs incapable of differentiating, morphologically normal discs with limited capacities for differentiation, and discs with homeotic transformations. In some mutants all discs were affected, and in others only certain discs. The most extreme abnormal phenotype is a class of “discless” mutants. The viability of these mutant larvae indicates that the discs are essential only for the development of an adult and not of a larva. The late lethals are therefore a major source of mutants for studying the genetic control of disc formation. Images PMID:5002822

  12. Intermediate mass black holes in AGN discs - I. Production and growth

    NASA Astrophysics Data System (ADS)

    McKernan, B.; Ford, K. E. S.; Lyra, W.; Perets, H. B.

    2012-09-01

    Here we propose a mechanism for efficiently growing intermediate mass black holes (IMBH) in discs around supermassive black holes. Stellar mass objects can efficiently agglomerate when facilitated by the gas disc. Stars, compact objects and binaries can migrate, accrete and merge within discs around supermassive black holes. While dynamical heating by cusp stars excites the velocity dispersion of nuclear cluster objects (NCOs) in the disc, gas in the disc damps NCO orbits. If gas damping dominates, NCOs remain in the disc with circularized orbits and large collision cross-sections. IMBH seeds can grow extremely rapidly by collisions with disc NCOs at low relative velocities, allowing for super-Eddington growth rates. Once an IMBH seed has cleared out its feeding zone of disc NCOs, growth of IMBH seeds can become dominated by gas accretion from the active galactic nucleus (AGN) disc. However, the IMBH can migrate in the disc and expand its feeding zone, permitting a super-Eddington accretion rate to continue. Growth of IMBH seeds via NCO collisions is enhanced by a pile-up of migrators. We highlight the remarkable parallel between the growth of IMBH in AGN discs with models of giant planet growth in protoplanetary discs. If an IMBH becomes massive enough it can open a gap in the AGN disc. IMBH migration in AGN discs may stall, allowing them to survive the end of the AGN phase and remain in galactic nuclei. Our proposed mechanisms should be more efficient at growing IMBH in AGN discs than the standard model of IMBH growth in stellar clusters. Dynamical heating of disc NCOs by cusp stars is transferred to the gas in an AGN disc helping to maintain the outer disc against gravitational instability. Model predictions, observational constraints and implications are discussed in a companion paper (Paper II).

  13. Synthesis of perfluoroalkylene aromatic diamines

    NASA Technical Reports Server (NTRS)

    Paciorek, K. L.; Ito, T. I.; Nakahara, J. H.; Kratzer, R. H.

    1978-01-01

    Analogues of methylene dianilines were synthesized, in which the methylene group between the two aromatic nuclei was replaced by various perfluoroalkylene linkage. The hydrolytic thermal, and thermal oxidative stabilities of PMR Polyimides derived from these diamines were determined. Three types of PMR Polyimide discs were fabricated from the dimethyl ester of 3,3', 4,4'-benzophenonetetracarboxylic acid, the methyl ester of 5-norbornene-2,3-dicarboxylic acid, and one of the following three diamines: methyl dianiline, 1,3-bis(4-aminophenyl)hexafluoropropane, and 2,2-bis(4-aminophenyl)hexafluoropropane. The polyimide based on 2,2-bis(4-aminophenyl)hexafluoropropane exhibited the best hydrolytic, thermal, and thermal oxidative stability as determined by moisture uptake and thermogravimetric analysis.

  14. Drill bit assembly for releasably retaining a drill bit cutter

    DOEpatents

    Glowka, David A.; Raymond, David W.

    2002-01-01

    A drill bit assembly is provided for releasably retaining a polycrystalline diamond compact drill bit cutter. Two adjacent cavities formed in a drill bit body house, respectively, the disc-shaped drill bit cutter and a wedge-shaped cutter lock element with a removable fastener. The cutter lock element engages one flat surface of the cutter to retain the cutter in its cavity. The drill bit assembly thus enables the cutter to be locked against axial and/or rotational movement while still providing for easy removal of a worn or damaged cutter. The ability to adjust and replace cutters in the field reduces the effect of wear, helps maintains performance and improves drilling efficiency.

  15. The effect of parental factors in children with large cup-to-disc ratios.

    PubMed

    Park, Hae-Young Lopilly; Ha, Min Ji; Shin, Sun Young

    2017-01-01

    To investigate large cup-to-disc ratios (CDR) in children and to determine the relationship between parental CDR and clinical characteristics associated with glaucoma. Two hundred thirty six children aged 6 to 12 years with CDR ≥ 0.6 were enrolled in this study. Subjects were classified into two groups based on parental CDR: disc suspect children with disc suspect (CDR ≥0.6) parents and disc suspect children without disc suspect parents. Ocular variables were compared between the two groups. Of the 236 disc suspect children, 100 (42.4%) had at least one disc suspect parent. Intraocular pressure (IOP) was higher in disc suspect children with disc suspect parents (16.52±2.66 mmHg) than in disc suspect children without disc suspect parents (14.38±2.30 mmHg, p = 0.023). In the group with disc suspect parents, vertical CDR significantly correlated with IOP (R = -0.325, p = 0.001), average retinal nerve fiber layer (RNFL) thickness (R = -0.319, p = 0.001), rim area (R = -0.740, p = 0.001), and cup volume (R = 0.499, p = 0.001). However, spherical equivalent (R = 0.333, p = 0.001), AL (R = -0.223, p = 0.009), and disc area (R = 0.325, p = 0.001) significantly correlated with vertical CDR in disc suspect children without disc suspect parents, in contrast to those with disc suspect parents. Larger vertical CDR was associated with the presence of disc suspect parents (p = 0.001), larger disc area (p = 0.001), thinner rim area (p = 0.001), larger average CDR (p = 0.001), and larger cup volume (p = 0.021). Family history of large CDR was a significant factor associated with large vertical CDR in children. In children with disc suspect parents, there were significant correlations between IOP and average RNFL thickness and vertical CDR.

  16. Effects of disc warping on the inclination evolution of star-disc-binary systems

    NASA Astrophysics Data System (ADS)

    Zanazzi, J. J.; Lai, Dong

    2018-07-01

    Several recent studies have suggested that circumstellar discs in young stellar binaries may be driven into misalignement with their host stars due to the secular gravitational interactions between the star, disc, and the binary companion. The disc in such systems is twisted/warped due to the gravitational torques from the oblate central star and the external companion. We calculate the disc warp profile, taking into account the bending wave propagation and viscosity in the disc. We show that for typical protostellar disc parameters, the disc warp is small, thereby justifying the `flat-disc' approximation adopted in previous theoretical studies. However, the viscous dissipation associated with the small disc warp/twist tends to drive the disc towards alignment with the binary or the central star. We calculate the relevant time-scales for the alignment. We find that the alignment is effective for sufficiently cold discs with strong external torques, especially for systems with rapidly rotating stars, but is ineffective for the majority of the star-disc-binary systems. Viscous warp-driven alignment may be necessary to account for the observed spin-orbit alignment in multiplanet systems if these systems are accompanied by an inclined binary companion.

  17. Simulating Dynamic Equilibria: A Class Experiment

    NASA Astrophysics Data System (ADS)

    Harrison, John A.; Buckley, Paul D.

    2000-08-01

    A first-order reversible reaction is simulated on an overhead projector using small coins or discs. A simulation is carried out in which initially there are 24 discs representing reactant A and none representing reactant B. At the end of each minute half of the reactant A discs get converted to reactant B, and one quarter of the reactant B discs get converted to reactant A discs. Equilibrium is established with 8 A discs and 16 B discs, and no further net change is observed as the simulation continues. Another simulation beginning with 48 A discs and 0 B discs leads at equilibrium to 16 A discs and 32 B discs. These results illustrate how dynamic equilibria are established and allow the introduction of the concept of an equilibrium constant. Le Châtelier's principle is illustrated by further simulations.

  18. Gas turbine sealing apparatus

    DOEpatents

    Wiebe, David J; Wessell, Brian J; Ebert, Todd; Beeck, Alexander; Liang, George; Marussich, Walter H

    2013-02-19

    A gas turbine includes forward and aft rows of rotatable blades, a row of stationary vanes between the forward and aft rows of rotatable blades, an annular intermediate disc, and a seal housing apparatus. The forward and aft rows of rotatable blades are coupled to respective first and second portions of a disc/rotor assembly. The annular intermediate disc is coupled to the disc/rotor assembly so as to be rotatable with the disc/rotor assembly during operation of the gas turbine. The annular intermediate disc includes a forward side coupled to the first portion of the disc/rotor assembly and an aft side coupled to the second portion of the disc/rotor assembly. The seal housing apparatus is coupled to the annular intermediate disc so as to be rotatable with the annular intermediate disc and the disc/rotor assembly during operation of the gas turbine.

  19. Manipulator having thermally conductive rotary joint for transferring heat from a test specimen

    DOEpatents

    Haney, S.J.; Stulen, R.H.; Toly, N.F.

    1983-05-03

    A manipulator for rotatably moving a test specimen in an ultra-high vacuum chamber includes a translational unit movable in three mutually perpendicular directions. A manipulator frame is rigidly secured to the translational unit for rotatably supporting a rotary shaft. A first copper disc is rigidly secured to an end of the rotary shaft for rotary movement within the vacuum chamber. A second copper disc is supported upon the first disc. The second disc receives a cryogenic cold head and does not rotate with the first disc. The second disc receives a cryogenic cold head and does not rotate with the first disc. A sapphire plate is interposed between the first and second discs to prevent galling of the copper material while maintaining high thermal conductivity between the first and second discs. A spring is disposed on the shaft to urge the second disc toward the first disc and compressingly engage the interposed sapphire plate. A specimen mount is secured to the first disc for rotation within the vacuum chamber. The specimen maintains high thermal conductivity with the second disc receiving the cryogenic transfer line.

  20. On the diversity and statistical properties of protostellar discs

    NASA Astrophysics Data System (ADS)

    Bate, Matthew R.

    2018-04-01

    We present results from the first population synthesis study of protostellar discs. We analyse the evolution and properties of a large sample of protostellar discs formed in a radiation hydrodynamical simulation of star cluster formation. Due to the chaotic nature of the star formation process, we find an enormous diversity of young protostellar discs, including misaligned discs, and discs whose orientations vary with time. Star-disc interactions truncate discs and produce multiple systems. Discs may be destroyed in dynamical encounters and/or through ram-pressure stripping, but reform by later gas accretion. We quantify the distributions of disc mass and radii for protostellar ages up to ≈105 yr. For low-mass protostars, disc masses tend to increase with both age and protostellar mass. Disc radii range from of order 10 to a few hundred au, grow in size on time-scales ≲ 104 yr, and are smaller around lower mass protostars. The radial surface density profiles of isolated protostellar discs are flatter than the minimum mass solar nebula model, typically scaling as Σ ∝ r-1. Disc to protostar mass ratios rarely exceed two, with a typical range of Md/M* = 0.1-1 to ages ≲ 104 yr and decreasing thereafter. We quantify the relative orientation angles of circumstellar discs and the orbit of bound pairs of protostars, finding a preference for alignment that strengths with decreasing separation. We also investigate how the orientations of the outer parts of discs differ from the protostellar and inner disc spins for isolated protostars and pairs.

  1. Novel localized heating technique on centrifugal microfluidic disc with wireless temperature monitoring system.

    PubMed

    Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman

    2015-01-01

    Recent advances in the field of centrifugal microfluidic disc suggest the need for electrical interface in the disc to perform active biomedical assays. In this paper, we have demonstrated an active application powered by the energy harvested from the rotation of the centrifugal microfluidic disc. A novel integration of power harvester disc onto centrifugal microfluidic disc to perform localized heating technique is the main idea of our paper. The power harvester disc utilizing electromagnetic induction mechanism generates electrical energy from the rotation of the disc. This contributes to the heat generation by the embedded heater on the localized heating disc. The main characteristic observed in our experiment is the heating pattern in relative to the rotation of the disc. The heating pattern is monitored wirelessly with a digital temperature sensing system also embedded on the disc. Maximum temperature achieved is 82 °C at rotational speed of 2000 RPM. The technique proves to be effective for continuous heating without the need to stop the centrifugal motion of the disc.

  2. Linear analysis of the evolution of nearly polar low-mass circumbinary discs

    NASA Astrophysics Data System (ADS)

    Lubow, Stephen H.; Martin, Rebecca G.

    2018-01-01

    In a recent paper Martin & Lubow showed through simulations that an initially tilted disc around an eccentric binary can evolve to polar alignment in which the disc lies perpendicular to the binary orbital plane. We apply linear theory to show both analytically and numerically that a nearly polar aligned low-mass circumbinary disc evolves to polar alignment and determine the alignment time-scale. Significant disc evolution towards the polar state around moderately eccentric binaries can occur for typical protostellar disc parameters in less than a typical disc lifetime for binaries with orbital periods of order 100 yr or less. Resonant torques are much less effective at truncating the inner parts of circumbinary polar discs than the inner parts of coplanar discs. For polar discs, they vanish for a binary eccentricity of unity. The results agree with the simulations in showing that discs can evolve to a polar state. Circumbinary planets may then form in such discs and reside on polar orbits.

  3. A new in vivo animal model to create intervertebral disc degeneration characterized by MRI, radiography, CT/discogram, biochemistry, and histology.

    PubMed

    Zhou, HaoWei; Hou, ShuXun; Shang, WeiLin; Wu, WenWen; Cheng, Yao; Mei, Fang; Peng, BaoGan

    2007-04-15

    A new in vivo sheep model was developed that produced disc degeneration through the injection of 5-bromodeoxyuridine (BrdU) into the intervertebral disc. This process was studied using magnetic resonance imaging (MRI), radiography, CT/discogram, histology, and biochemistry. To develop a sheep model of intervertebral disc degeneration that more faithfully mimics the pathologic hallmarks of human intervertebral disc degeneration. Recent studies have shown age-related alterations in proteoglycan structure and organization in human intervertebral discs. An animal model that involves the use of age-related changes in disc cells can be beneficial over other more invasive degenerative models that involves directly damaging the matrix of disc tissue. Twelve sheep were injected with BrdU or vehicle (phosphate-buffered saline) into the central region of separate lumbar discs. Intact discs were used as controls. At the 2-, 6-, 10-, and 14-week time points, discs underwent MRI, radiography, histology, and biochemical analyses. A CT/discogram study was performed at the 14-week time point. MRI demonstrated a progressive loss of T2-weighted signal intensity at BrdU-injected discs over the 14-week study period. Radiograph findings included osteophyte and disc space narrowing formed by 10 weeks post-BrdU treatment. CT discography demonstrated internal disc disruption in several BrdU-treated discs at the 14-week time point. Histology showed a progressive loss of the normal architecture and cell density of discs from the 2-week time point to the 14-week time point. A progressive loss of cell proliferation capacity, water content, and proteoglycans was also documented. BrdU injection into the central region of sheep discs resulted in degeneration of intervertebral discs. This progressive, degenerative process was confirmed using MRI, histology, and by observing changes in biochemistry. Degeneration occurred in a manner that was similar to that observed in human disc degeneration.

  4. Are Collapsed Cervical Discs Amenable to Total Disc Arthroplasty?: Analysis of Prospective Clinical Data With 2-Year Follow Up.

    PubMed

    Patwardhan, Avinash G; Carandang, Gerard; Voronov, Leonard I; Havey, Robert M; Paul, Gary A; Lauryssen, Carl; Coric, Domagoj; Dimmig, Thomas; Musante, David

    2016-12-15

    Analysis of prospectively collected radiographic data. To investigate the influence of preoperative index-level range of motion (ROM) and disc height on postoperative ROM after cervical total disc arthroplasty (TDA) using compressible disc prostheses. Clinical studies demonstrate benefits of motion preservation over fusion; however, questions remain unanswered as to which preoperative factors have the ability to identify patients who are most likely to have good postoperative motion, which is the primary rationale for TDA. We analyzed prospectively collected data from a single-arm, multicenter study with 2-year follow up of 30 patients with 48 implanted levels. All received compressible cervical disc prostheses of 6 mm-height (M6C, Spinal Kinetics, Sunnyvale, CA). The influence of index-level preoperative disc height and ROM (each with two levels: below-median and above-median) on postoperative ROM was analyzed using 2 x 2 ANOVA. We further analyzed the radiographic outcomes of a subset of discs with preoperative height less than 3 mm, the so-called "collapsed" discs. Shorter (3.0 ± 0.4 mm) discs were significantly less mobile preoperatively than taller (4.4 ± 0.5 mm) discs (6.7° vs. 10.5°, P = 0.01). The postoperative ROM did not differ between the shorter and taller discs (5.6° vs. 5.0°, P = 0.63). Tall discs that were less mobile preoperatively had significantly smaller postoperative ROM than short discs with above-median preoperative mobility (P < 0.05). The "collapsed discs" (n = 8) were less mobile preoperatively compared with all discs combined (5.1° vs. 8.6°, P < 0.01). These discs were distracted to more than two times the preoperative height, from 2.6 to 5.7 mm, and had significantly greater postoperative ROM than all discs combined (7.6° vs. 5.3°, P < 0.05). We observed a significant interaction between preoperative index-level disc height and ROM in influencing postoperative ROM. Although limited by small sample size, the results suggest discs with preoperative height less than 3 mm may be amenable to disc arthroplasty using compressible disc prostheses. 2.

  5. CT morphometry of adult thoracic intervertebral discs.

    PubMed

    Fletcher, Justin G R; Stringer, Mark D; Briggs, Christopher A; Davies, Tilman M; Woodley, Stephanie J

    2015-10-01

    Despite being commonly affected by degenerative disorders, there are few data on normal thoracic intervertebral disc dimensions. A morphometric analysis of adult thoracic intervertebral discs was, therefore, undertaken. Archival computed tomography scans of 128 recently deceased individuals (70 males, 58 females, 20-79 years) with no known spinal pathology were analysed to determine thoracic disc morphometry and variations with disc level, sex and age. Reliability was assessed by intraclass correlation coefficients (ICCs). Anterior and posterior intervertebral disc heights and axial dimensions were significantly greater in men (anterior disc height 4.0±1.4 vs 3.6±1.3 mm; posterior disc height 3.6±0.90 vs 3.4±0.93 mm; p<0.01). Disc heights and axial dimensions at T4-5 were similar or smaller than at T2-3, but thereafter increased caudally (mean anterior disc height T4-5 and T10-11, 2.7±0.7 and 5.4±1.2 mm, respectively, in men; 2.6±0.8 and 5.1±1.3 mm, respectively, in women; p<0.05). Except at T2-3, anterior disc height decreased with advancing age and anteroposterior and transverse disc dimensions increased; posterior and middle disc heights and indices of disc shape showed no consistent statistically significant changes. Most parameters showed substantial to almost perfect agreement for intra- and inter-rater reliability. Thoracic disc morphometry varies significantly and consistently with disc level, sex and age. This study provides unique reference data on adult thoracic intervertebral disc morphometry, which may be useful when interpreting pathological changes and for future biomechanical and functional studies.

  6. Geometrical Effects in Two-Dimensional Arrays of Josephson Junctions

    DTIC Science & Technology

    1992-05-01

    Iot (4.3.4.b) dyd a .. s -f sin =o0 (4.3.4.c) ~r Tdr n snadrs where a, 13, and rare the gauge-invariant phase differences denoted in Fig. 4.8. If we...Receive Slit Coils *_ * Slit Set-screw / -Tr Drive Coil IDrive Leads if Coil Fig. 8.7. Schematic drawing of the two-coil mututal-inductance apparatus we

  7. Clinical, epidemiological and treatment failure data among HIV-1 non-B-infected patients in the Spanish AIDS Research Network Cohort.

    PubMed

    Torrecilla García, Esther; Yebra Sanz, Gonzalo; Llácer-Delicado, Teresa; Rubio García, Rafael; González-García, Juan; García García, Federico; López-Aldeguer, José; Asensi Álvarez, Víctor; Holguín Fernández, África

    2016-01-01

    The prevalence of HIV-1 non-B variants is increasing in Spain, showing a higher number of transmitted drug resistance mutations (TDR) since 2002. This study presents the features of non-B-infected patients enrolled in the cohort of antiretroviral treatment (ART) naïve HIV-infected patients included in the Research Network on HIV/AIDS (CoRIS). The study includes a selected group of HIV-1 non-B-infected subjects from 670 subjects with pol sequences collected from 2004 to 2008 in the CoRIS cohort. Epidemiological-clinical-virological data were analyzed since cohort entry until October 2011, considering the presence or absence of treatment failure (TF). Eighty two non-B infected subjects with known HIV-1 variants were selected from 2004 to 2008 in the CoRIS cohort, being mainly female, immigrants, infected by recombinant viruses, and by heterosexual route. They had an intermediate TDR rate (9.4%), a high rate of TF (25.6%), of losses to follow-up (35%), of coinfections (32.9%), and baseline CD4+ counts ≥350cells/mm(3) (61.8%). Non-B subjects with TF showed higher rates of heterosexual infection (85.7% vs. 69.5%, p<0.05), tuberculosis (30.8% vs. 9.1%, p=0.10) and hepatitis C (23.8% vs. 13.9%, p=0.34) coinfections and lower rates of syphilis (0% vs. 21.9%, p<0.05), and had more frequently received first-line ART including protease inhibitors (PIs) than patients without TF (70% vs. 30%, p<0.05). Interestingly, infection with non-B variants reduced the risk of TDR to nucleoside reverse transcriptase inhibitors and increased the risk to PIs. HIV-1 non-B-infected patients in Spain had a particular epidemiological and clinical profile that should be considered during their clinical management. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  8. Bibliometric analysis of worldwide publications on multi-, extensively, and totally drug - resistant tuberculosis (2006-2015).

    PubMed

    Sweileh, Waleed M; AbuTaha, Adham S; Sawalha, Ansam F; Al-Khalil, Suleiman; Al-Jabi, Samah W; Zyoud, Sa'ed H

    2016-01-01

    The year 2015 marked the end of United Nations Millennium Development Goals which was aimed at halting and reversing worldwide tuberculosis (TB). The emergence of drug resistance is a major challenge for worldwide TB control. The aim of this study was to give a bibliometric overview of publications on multi-, extensively, and totally drug-resistant TB. Scopus database was used to retrieve articles on multidrug resistant (MDR), extensively drug-resistant (XDR), and totally drug-resistant (TDR) tuberculosis for the study period (2006-2015). The number of publications, top productive countries and institutions, citation analysis, co-authorships, international collaboration, active authors, and active journals were retrieved and analyzed. A total of 2260 journal articles were retrieved. The mean ± SD citations per article was 7.04 ± 16.0. The h -index of retrieved data was 76. The number of publications showed a three - fold increase over the study period compared with less than two - fold increase in tuberculosis research during the same study period. Stratified by number of publications, the United States of America ranked first while Switzerland ranked first in productivity per 100 million people, and South Africa ranked first in productivity stratified per one trillion Gross Domestic Product. Three of the High Burden Countries (HBC) MDR-TB (India, China, and South Africa) were present in top productive countries. High percentage of international collaboration was seen among most HBC MDR-TB. Except for Plos One journal, most active journals in publishing articles on MDR, XDR, TDR-TB were in infection - related fields and in general medicine. Top 20 cited articles were published in prestigious journal such as Lancet and New England Journal of Medicine . The themes in top 20 cited articles were diverse, ranging from molecular biology, diagnostic tools, co-infection with HIV, and results of new anti-TB drugs. Publications on MDR, XDR and TDR - TB are increasing in the past decade. International collaboration was common. Many low resourced African and Asian countries will benefit from research leading to new diagnostic and screening technology of TB. The exchange of expertise, ideas and technology is of paramount importance in this field.

  9. Monitoring water cycle elements using GNSS geodetic receivers at the field research station Marquardt, Germany

    NASA Astrophysics Data System (ADS)

    Simeonov, Tzvetan; Vey, Sibylle; Alshawaf, Fadwa; Dick, Galina; Guerova, Guergana; Güntner, Andreas; Hohmann, Christian; Kunwar, Ajeet; Trost, Benjamin; Wickert, Jens

    2017-04-01

    Water storage variations in the atmosphere and in soils are among the most dynamic within the Earth's water cycle. The continuous measurement of water storage in these media with a high spatial and temporal resolution is a challenging task, not yet completely solved by various observation techniques. With the development of the Global Navigation Satellite Systems (GNSS) a new approach for atmospheric water vapor estimation in the atmosphere and in parallel of soil moisture in the vicinity of GNSS ground stations was established in the recent years with several key advantages compared to traditional techniques. Regional and global GNSS networks are nowadays operationally used to provide the Integrated Water Vapor (IWV) information with high temporal resolution above the individual stations. Corresponding data products are used to improve the day-by-day weather prediction of leading forecast centers. Selected stations from these networks can be used to additionally derive the soil moisture in the vicinity of the receivers. Such parallel measurement of IWV and soil moisture using a single measuring device provides a unique possibility to analyze water fluxes between the atmosphere and the land surface. We installed an advanced experimental GNSS setup for hydrology at the field research station of the Leibniz Institute for Agricultural Engineering and Bioeconomy in Marquardt, around 30km West of Berlin, Germany. The setup includes several GNSS receivers, various Time Domain Reflectometry (TDR) sensors at different depths for soil moisture measurement and an meteorological station. The setup was mainly installed to develop and improve GNSS based techniques for soil moisture determination and to analyze GNSS IWV and SM in parallel on a long-term perspective. We introduce initial results from more than two years of measurements. The comparison in station Marquardt shows good agreement (correlation 0.79) between the GNSS derived soil moisture and the TDR measurements. A detailed study for several periods with different GNSS settings, vegetation and soil conditions in the vicinity of the station is presented with emphasis on the behavior of GNSS derived soil moisture, compared to TDR. Case studies of intense rainfall events and lasting dry periods show the interaction between the IWV and soil moisture.

  10. Technical features and criteria in designing fiber-reinforced composite materials: from the aerospace and aeronautical field to biomedical applications.

    PubMed

    Gloria, Antonio; Ronca, Dante; Russo, Teresa; D'Amora, Ugo; Chierchia, Marianna; De Santis, Roberto; Nicolais, Luigi; Ambrosio, Luigi

    2011-01-01

    Polymer-based composite materials are ideal for applications where high stiffness-to-weight and strength-to-weight ratios are required. From aerospace and aeronautical field to biomedical applications, fiber-reinforced polymers have replaced metals, thus emerging as an interesting alternative. As widely reported, the mechanical behavior of the composite materials involves investigation on micro- and macro-scale, taking into consideration micromechanics, macromechanics and lamination theory. Clinical situations often require repairing connective tissues and the use of composite materials may be suitable for these applications because of the possibility to design tissue substitutes or implants with the required mechanical properties. Accordingly, this review aims at stressing the importance of fiber-reinforced composite materials to make advanced and biomimetic prostheses with tailored mechanical properties, starting from the basic principle design, technologies, and a brief overview of composites applications in several fields. Fiber-reinforced composite materials for artificial tendons, ligaments, and intervertebral discs, as well as for hip stems and mandible models will be reviewed, highlighting the possibility to mimic the mechanical properties of the soft and hard tissues that they replace.

  11. Quantitating Human Optic Disc Topography

    NASA Astrophysics Data System (ADS)

    Graebel, William P.; Cohan, Bruce E.; Pearch, Andrew C.

    1980-07-01

    A method is presented for quantitatively expressing the topography of the human optic disc, applicable in a clinical setting to the diagnosis and management of glaucoma. Pho-tographs of the disc illuminated by a pattern of fine, high contrast parallel lines are digitized. From the measured deviation of the lines as they traverse the disc surface, disc topography is calculated, using the principles of optical sectioning. The quantitators applied to express this topography have the the following advantages : sensitivity to disc shape; objectivity; going beyond the limits of cup-disc ratio estimates and volume calculations; perfect generality in a mathematical sense; an inherent scheme for determining a non-subjective reference frame to compare different discs or the same disc over time.

  12. Asymmetric MHD outflows/jets from accreting T Tauri stars

    NASA Astrophysics Data System (ADS)

    Dyda, S.; Lovelace, R. V. E.; Ustyugova, G. V.; Lii, P. S.; Romanova, M. M.; Koldoba, A. V.

    2015-06-01

    Observations of jets from young stellar objects reveal the asymmetric outflows from some sources. A large set of 2.5D magnetohydrodynamic simulations was carried out for axisymmetric viscous/diffusive disc accretion to rotating magnetized stars for the purpose of assessing the conditions where the outflows are asymmetric relative to the equatorial plane. We consider initial magnetic fields that are symmetric about the equatorial plane and consist of a radially distributed field threading the disc (disc field) and a stellar dipole field. (1) For pure disc-fields the symmetry or asymmetry of the outflows is affected by the mid-plane plasma β of the disc. For discs with small plasma β, outflows are symmetric to within 10 per cent over time-scales of hundreds of inner disc orbits. For higher β discs, the coupling of the upper and lower coronal plasmas is broken, and quasi-periodic field motion leads to asymmetric episodic outflows. (2) Accreting stars with a stellar dipole field and no disc-field exhibit episodic, two component outflows - a magnetospheric wind and an inner disc wind. Both are characterized by similar velocity profiles but the magnetospheric wind has densities ≳ 10 times that of the disc wind. (3) Adding a disc field parallel to the stellar dipole field enhances the magnetospheric winds but suppresses the disc wind. (4) Adding a disc field which is antiparallel to the stellar dipole field in the disc suppresses the magnetospheric and disc winds. Our simulations reproduce some key features of observations of asymmetric outflows of T Tauri stars.

  13. Ranges of Cervical Intervertebral Disc Deformation During an In Vivo Dynamic Flexion–Extension of the Neck

    PubMed Central

    Yu, Yan; Mao, Haiqing; Li, Jing-Sheng; Tsai, Tsung-Yuan; Cheng, Liming; Wood, Kirkham B.; Li, Guoan; Cha, Thomas D.

    2017-01-01

    While abnormal loading is widely believed to cause cervical spine disc diseases, in vivo cervical disc deformation during dynamic neck motion has not been well delineated. This study investigated the range of cervical disc deformation during an in vivo functional flexion–extension of the neck. Ten asymptomatic human subjects were tested using a combined dual fluoroscopic imaging system (DFIS) and magnetic resonance imaging (MRI)-based three-dimensional (3D) modeling technique. Overall disc deformation was determined using the changes of the space geometry between upper and lower endplates of each intervertebral segment (C3/4, C4/5, C5/6, and C6/7). Five points (anterior, center, posterior, left, and right) of each disc were analyzed to examine the disc deformation distributions. The data indicated that between the functional maximum flexion and extension of the neck, the anterior points of the discs experienced large changes of distraction/compression deformation and shear deformation. The higher level discs experienced higher ranges of disc deformation. No significant difference was found in deformation ranges at posterior points of all the discs. The data indicated that the range of disc deformation is disc level dependent and the anterior region experienced larger changes of deformation than the center and posterior regions, except for the C6/7 disc. The data obtained from this study could serve as baseline knowledge for the understanding of the cervical spine disc biomechanics and for investigation of the biomechanical etiology of disc diseases. These data could also provide insights for development of motion preservation surgeries for cervical spine. PMID:28334358

  14. Ranges of Cervical Intervertebral Disc Deformation During an In Vivo Dynamic Flexion-Extension of the Neck.

    PubMed

    Yu, Yan; Mao, Haiqing; Li, Jing-Sheng; Tsai, Tsung-Yuan; Cheng, Liming; Wood, Kirkham B; Li, Guoan; Cha, Thomas D

    2017-06-01

    While abnormal loading is widely believed to cause cervical spine disc diseases, in vivo cervical disc deformation during dynamic neck motion has not been well delineated. This study investigated the range of cervical disc deformation during an in vivo functional flexion-extension of the neck. Ten asymptomatic human subjects were tested using a combined dual fluoroscopic imaging system (DFIS) and magnetic resonance imaging (MRI)-based three-dimensional (3D) modeling technique. Overall disc deformation was determined using the changes of the space geometry between upper and lower endplates of each intervertebral segment (C3/4, C4/5, C5/6, and C6/7). Five points (anterior, center, posterior, left, and right) of each disc were analyzed to examine the disc deformation distributions. The data indicated that between the functional maximum flexion and extension of the neck, the anterior points of the discs experienced large changes of distraction/compression deformation and shear deformation. The higher level discs experienced higher ranges of disc deformation. No significant difference was found in deformation ranges at posterior points of all the discs. The data indicated that the range of disc deformation is disc level dependent and the anterior region experienced larger changes of deformation than the center and posterior regions, except for the C6/7 disc. The data obtained from this study could serve as baseline knowledge for the understanding of the cervical spine disc biomechanics and for investigation of the biomechanical etiology of disc diseases. These data could also provide insights for development of motion preservation surgeries for cervical spine.

  15. The presence of pleiotrophin in the human intervertebral disc is associated with increased vascularization: an immunohistologic study.

    PubMed

    Johnson, William E B; Patterson, Angela M; Eisenstein, Stephen M; Roberts, Sally

    2007-05-20

    An immunohistological study of surgical specimens of human intervertebral disc. To examine the presence of pleiotrophin in diseased or damaged intervertebral disc tissue and the association between its presence and the extent of tissue vascularization and innervation. Increased levels of pleiotrophin, a growth and differentiation factor that is active in various pathophysiologic processes, including angiogenesis, has been associated with osteoarthritic changes of human articular cartilage. The association between pleiotrophin expression and pathologic conditions of the human intervertebral disc is unknown. Specimens of human lumbar intervertebral discs, obtained following surgical discectomy, were divided into 3 groups: non-degenerated discs (n = 7), degenerated discs (n = 6), and prolapsed discs (n = 11). Serial tissue sections of each specimen were immunostained to determine the presence of pleiotrophin, blood vessels (CD34-positive endothelial cells), and nerves (neurofilament 200 kDa [NF200]-positive nerve fibers). Pleiotrophin immunoreactivity was seen in disc cells, endothelial cells, and in the extracellular matrix in most specimens of intervertebral disc but was most prevalent in vascularized tissue in prolapsed discs. There was a significant correlation between the presence of pleiotrophin-positive disc cells and that of CD34-positive blood vessels. NF200-positive nerves were seen in vascularized areas of more degenerated discs, but nerves did not appear to codistribute with blood vessels or pleiotrophin positivity in prolapsed discs. Pleiotrophin is present in pathologic human intervertebral discs, and its prevalence and distribution suggest that it may play a role in neovascularization of diseased or damaged disc tissue.

  16. Retrieval analysis of motion preserving spinal devices and periprosthetic tissues

    PubMed Central

    Kurtz, Steven M.; Steinbeck, Marla; Ianuzzi, Allyson; van Ooij, André; Punt, Ilona M.; Isaza, Jorge; Ross, E.R.S.

    2009-01-01

    This article reviews certain practical aspects of retrieval analysis for motion preserving spinal implants and periprosthetic tissues as an essential component of the overall revision strategy for these implants. At our institution, we established an international repository for motion-preserving spine implants in 2004. Our repository is currently open to all spine surgeons, and is intended to be inclusive of all cervical and lumbar implant designs such as artificial discs and posterior dynamic stabilization devices. Although a wide range of alternative materials is being investigated for nonfusion spine implants, many of the examples in this review are drawn from our existing repository of metal-on-polyethylene, metal-on-metal lumbar total disc replacements (TDRs), and polyurethane-based dynamic motion preservation devices. These devices are already approved or nearing approval for use in the United States, and hence are the most clinically relevant at the present time. This article summarizes the current literature on the retrieval analysis of these implants and concludes with recommendations for the development of new test methods that are based on the current state of knowledge of in vivo wear and damage mechanisms. Furthermore, the relevance and need to evaluate the surrounding tissue to obtain a complete understanding of the biological reaction to implant component corrosion and wear is reviewed. PMID:25802641

  17. In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials.

    PubMed

    Scholes, Susan C; Joyce, Thomas J

    2013-06-01

    Bovine serum is the lubricant recommended by several international standards for the wear testing of orthopaedic biomaterials; however, there are issues over its use due to batch variation, degradation, cost and safety. For these reasons, alternative lubricants were investigated. A 50-station Super-CTPOD (circularly translating pin-on-disc) wear test rig was used, which applied multidirectional motion to ultra-high-molecular-weight polyethylene test pins rubbing against cobalt chromium discs. Thirteen possible alternative lubricants were tested. The use of soy protein as a lubricant gave statistically higher wear, while soya oil, olive oil, Channel Island milk, whole milk, whey, wheatgerm oil, 11 mg/mL egg white, albumin/globulin mix and albumin/globulin/chondroitin sulphate mix all gave statistically lower wear than bovine serum. The lubricants giving the closest wear results to bovine serum were 20 and 40 mg/mL egg white solutions. A light absorbance assay found that these egg white solutions suffered from a high degradation rate that increased with increasing protein content. While egg white solutions offer the best alternative lubricant to bovine serum due to the wear volumes produced, cost-effectiveness and safety of handling, protein degradation will still occur, leading to the need for regular lubricant replacement. Of the lubricants tested in this study, none were found to be superior to bovine serum.

  18. In-situ photopolymerized and monitored implants: successful application to an intervertebral disc replacement

    NASA Astrophysics Data System (ADS)

    Schmocker, Andreas M.; Khoushabi, Azadeh; Bourban, Pierre-Etienne; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe

    2016-02-01

    Photopolymerization is a common method to harden materials initially in a liquid state. A surgeon can directly trigger the solidification of a dental implant or a bone or tissue filler by using ultra-violet light. Traditionally, photopolymerization has been used mainly in dentistry. Over the last decade advances in material development including a wide range of biocompatible gel- and cement-systems open up a new avenue for in-situ photopolymerization. We designed a miniaturized light probe where a photoactive material can be 1) mixed, pressurized and injected 2) photopolymerized or photoactivated and 3) monitored during the chemical reaction. The device enables surgeries to be conducted through a hole smaller than 500 μm in diameter. Using a combination of Raman and fluorescence spectroscopy, the current state of the photopolymerization was inferred and monitored in real time within an in-vitro tissue model. It was also possible to determine roughly the position of the probe within the tissue cavity by analysing the fluorescence signal. Using the technique hydrogels were successfully implanted into a bovine intervertebral disc model. Mechanical tests could not obstruct the functionality of the implant. Finally, the device was also used for other application such as the implantation of a hydrogel into an aneurysm tissue cavity which will be presented at the conference.

  19. MRI evaluation of spontaneous intervertebral disc degeneration in the alpaca cervical spine.

    PubMed

    Stolworthy, Dean K; Bowden, Anton E; Roeder, Beverly L; Robinson, Todd F; Holland, Jacob G; Christensen, S Loyd; Beatty, Amanda M; Bridgewater, Laura C; Eggett, Dennis L; Wendel, John D; Stieger-Vanegas, Susanne M; Taylor, Meredith D

    2015-12-01

    Animal models have historically provided an appropriate benchmark for understanding human pathology, treatment, and healing, but few animals are known to naturally develop intervertebral disc degeneration. The study of degenerative disc disease and its treatment would greatly benefit from a more comprehensive, and comparable animal model. Alpacas have recently been presented as a potential large animal model of intervertebral disc degeneration due to similarities in spinal posture, disc size, biomechanical flexibility, and natural disc pathology. This research further investigated alpacas by determining the prevalence of intervertebral disc degeneration among an aging alpaca population. Twenty healthy female alpacas comprised two age subgroups (5 young: 2-6 years; and 15 older: 10+ years) and were rated according to the Pfirrmann-grade for degeneration of the cervical intervertebral discs. Incidence rates of degeneration showed strong correlations with age and spinal level: younger alpacas were nearly immune to developing disc degeneration, and in older animals, disc degeneration had an increased incidence rate and severity at lower cervical levels. Advanced disc degeneration was present in at least one of the cervical intervertebral discs of 47% of the older alpacas, and it was most common at the two lowest cervical intervertebral discs. The prevalence of intervertebral disc degeneration encourages further investigation and application of the lower cervical spine of alpacas and similar camelids as a large animal model of intervertebral disc degeneration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Archival-grade optical disc design and international standards

    NASA Astrophysics Data System (ADS)

    Fujii, Toru; Kojyo, Shinichi; Endo, Akihisa; Kodaira, Takuo; Mori, Fumi; Shimizu, Atsuo

    2015-09-01

    Optical discs currently on the market exhibit large variations in life span among discs, making them unsuitable for certain business applications. To assess and potentially mitigate this problem, we performed accelerated degradation testing under standard ISO conditions, determined the probable disc failure mechanisms, and identified the essential criteria necessary for a stable disc composition. With these criteria as necessary conditions, we analyzed the physical and chemical changes that occur in the disc components, on the basis of which we determined technological measures to reduce these degradation processes. By applying these measures to disc fabrication, we were able to develop highly stable optical discs.

Top