NASA Astrophysics Data System (ADS)
Bodor, Petra; Eröss, Anita; Kovács, József; Mádl-Szönyi, Judit
2016-04-01
The subsurface part of the hydrologic cycle, the saturated groundwater flow can be mostly studied in regional discharge areas. In these regions the water has already spent geologically long time under the surface, therefore the upwelling water reflect the effect of the geometry and boundary conditions of the whole flow field, its geology and chemical processes. According to these conditions, the discharging waters can be characterized with different values and variability of physicochemical parameters (temperature, total dissolved solids, cations, anions, gas content etc.). This question has special interest in carbonate systems where the concept of regional groundwater flow was only introduced in the last few years. Hydrographs and chemographs are frequently used in karst studies to demonstrate the effect of variability of the system and to derive information for the nature of flow inside the karst (channel, fracture or matrix). Usually these graphs show abrupt changes after precipitation events, but this is typical for epigenic karsts. However, discharge areas, where hypogenic karsts developed, can behave differently due to their feeding flow systems. These systems and their effects are not so well studied yet. In this study we examined hydrographs and chemographs of the regional discharge area of a deep and thick carbonate range of Buda Thermal Karst and tried to understand those mechanisms which determine the hydrological and hydrochemical behaviour of the region. Here cold, lukewarm and also thermal waters discharge along the River Danube. The variability of physicochemical parameters (temperature, electric conductivity, pH, volume discharge, water level, dissolved CO2 and 222Rn, δ18O, δD) of the discharging water was studied to understand influencing mechanisms. We tried to understand the effect of precipitation (short and long term) and the effect of River Danube with geomathematical methods for the lukewarm components of the discharging water. Based on the results, it was found that the hydrological and hydrochemical parameters of the regional discharge zone are only slightly variable compared to the other parts of the system. The local effect of precipitation is not detectable at the area, and it has only buffered influence in the recharge zone based on comparison with integrated precipitation. However, this buffered effect is eliminated at the discharge zone. It means that these regional discharge zones of carbonates are less sensitive to the change in short and long term climatic conditions. This can be explained easily by their position in the gravity-driven flow systems. However, the transient effect of the river influences the discharge conditions, therefore the hydrological and hydrochemical conditions. These findings display the quasi permanent flow conditions regarding the regional discharge areas of carbonates with the superimposed transient effect of the river. The research was supported by the NK 101356 OTKA research grant.
Discharge transient coupling in large space power systems
NASA Technical Reports Server (NTRS)
Stevens, N. John; Stillwell, R. P.
1990-01-01
Experiments have shown that plasma environments can induce discharges in solar arrays. These plasmas simulate the environments found in low earth orbits where current plans call for operation of very large power systems. The discharges could be large enough to couple into the power system and possibly disrupt operations. Here, the general concepts of the discharge mechanism and the techniques of coupling are discussed. Data from both ground and flight experiments are reviewed to obtain an expected basis for the interactions. These concepts were applied to the Space Station solar array and distribution system as an example of the large space power system. The effect of discharges was found to be a function of the discharge site. For most sites in the array discharges would not seriously impact performance. One location at the negative end of the array was identified as a position where discharges could couple to charge stored in system capacitors. This latter case could impact performance.
Wheatcroft, R.A.; Goni, M.A.; Hatten, J.A.; Pasternack, G.B.; Warrick, J.A.
2010-01-01
Recent research has shown that small, mountainous river systems (SMRS) account for a significant fraction of the global flux of sediment and particulate organic carbon (POC) to the ocean. The enormous number of SMRS precludes intensive studies of the sort conducted on large systems, necessitating development of a conceptual framework that permits cross-system comparison and scaling up. Herein, we introduce the geomorphic concept of effective discharge to the problem of source-to-sink POC transport. This idea recognizes that transport effectiveness is the product of discharge frequency and magnitude, wherein the latter is quantified as a power-law relationship between discharge and load (the 'rating curve'). An analytical solution for effective discharge (Qe) identifies two key variables: the standard deviation of the natural logarithm of discharge (??q), and the rating exponent of constituent i (bi Data from selected SMRS are used to show that for a given river Qe-POC < Qesediment, Qe for different POC constituents (e.g., POCfossil vs. POC(modern) differs in predictable ways, and Qe for a particular constituent can vary seasonally. When coupled with the idea that discharge peaks of small rivers may be coincident with specific oceanic conditions (e.g., large waves, wind from a certain direction) that determine dispersal and burial, these findings have potentially important implications for POC fate on continental margins. Future studies of POC transport in SMRS should exploit the conceptual framework provided herein and seek to identify how constituent-specific effective discharges vary between rivers and respond to perturbations. ?? 2010, by the American Society of Limnology and Oceanography, Inc.
A comparative study on the activity of TiO2 in pulsed plasma under different discharge conditions
NASA Astrophysics Data System (ADS)
Lijuan, DUAN; Nan, JIANG; Na, LU; Kefeng, SHANG; Jie, LI; Yan, WU
2018-05-01
In the present study, a combination of pulsed discharge plasma and TiO2 (plasma/TiO2) has been developed in order to study the activity of TiO2 by varying the discharge conditions of pulsed voltage, discharge mode, air flow rate and solution conductivity. Phenol was used as the chemical probe to characterize the activity of TiO2 in a pulsed discharge system. The experimental results showed that the phenol removal efficiency could be improved by about 10% by increasing the applied voltage. The phenol removal efficiency for three discharge modes in the plasma-discharge-alone system was found to be highest in the spark mode, followed by the spark–streamer mode and finally the streamer mode. In the plasma/TiO2 system, the highest catalytic effect of TiO2 was observed in the spark–streamer discharge mode, which may be attributed to the favorable chemical and physical effects from the spark–streamer discharge mode, such as ultraviolet light, O3, H2O2, pyrolysis, shockwaves and high-energy electrons. Meanwhile, the optimal flow rate and conductivity were 0.05 m3 l‑1 and 10 μS cm‑1, respectively. The main phenolic intermediates were hydroquinone, catechol, and p-benzoquinone during the discharge treatment process. A different phenol degradation pathway was observed in the plasma/TiO2 system as compared to plasma alone. Analysis of the reaction intermediates demonstrated that p-benzoquinone reduction was selectively catalyzed on the TiO2 surface. The effective decomposition of phenol constant (D e) increased from 74.11% to 79.16% when TiO2 was added, indicating that higher phenol mineralization was achieved in the plasma/TiO2 system.
Challenges in Patient Discharge Planning in the Health System of Iran: A Qualitative Study
Gholizadeh, Masumeh; Delgoshaei, Bahram; Gorji, Hasan Abulghasem; Torani, Sogand; Janati, Ali
2016-01-01
Background: One of the main factors relating to quality of hospitals is effective discharge planning. Discharge planning promotes the quality of inpatient care and reduces unplanned hospital readmission. The current study investigated the challenges of discharge planning observed in the health system of Iran. Methods: This qualitative research was conducted using a thematic and framework analyses to identify the challenges under each themes defined by the World Health Organization (WHO), to understand barriers in developing an effective discharge planning system in Iran health system. The data was collected from detailed semi-structured interviews and sessions of focus group discussions. This study involved 51 participants including health policy makers, hospital and health managers, faculty members, nurses, practitioners, community medicine specialists and other professionals of the Ministry of Health and Medical Education (MOHME). To reduce the bias and to increase the credibility of the study, evaluation criteria from Lincoln and Guba were used. All interviews and FGDs were recorded and transcribed, then analyzed by the software MAXQDA-11 and also manually. Results: According to the WHO health systems framework, challenges of effective hospital discharge planning were divided into six areas, leadership/governance, service delivery, information, financing, health workforce, and medical production(themes), in which there were 5,3,2,2,3,1 subthemes respectively. Conclusion: It is evident from the findings of this study that changes in the perspective of policy makers, health staff and managers, strengthening of systematic approach, and establishment of required infrastructures are essential for successful implementation of effective discharge planning in health systems in Iran. PMID:26755460
NASA Technical Reports Server (NTRS)
Hruby, Vladimir (Inventor); Demmons, Nathaniel (Inventor); Ehrbar, Eric (Inventor); Pote, Bruce (Inventor); Rosenblad, Nathan (Inventor)
2014-01-01
An autonomous method for minimizing the magnitude of plasma discharge current oscillations in a Hall effect plasma device includes iteratively measuring plasma discharge current oscillations of the plasma device and iteratively adjusting the magnet current delivered to the plasma device in response to measured plasma discharge current oscillations to reduce the magnitude of the plasma discharge current oscillations.
Environmentally-induced voltage limitations in large space power systems
NASA Technical Reports Server (NTRS)
Stevens, N. J.
1984-01-01
Large power systems proposed for future space missions imply higher operating voltage requirements which, in turn, will interact with the space plasma environment. The effects of these interactions can only be inferred because of the limited data base of ground simulations, small test samples, and two space flight experiments. This report evaluates floating potentials for a 100 kW power system operating at 300, 500, 750, and 1000 volts in relation to this data base. Of primary concern is the possibility of discharging to space. The implications of such discharges were studied at the 500 volt operational setting. It was found that discharging can shut down the power system if the discharge current exceeds the array short circuit current. Otherwise, a power oscillation can result that ranges from 2 to 20 percent, depending upon the solar array area involved in the discharge. Means of reducing the effect are discussed.
Noyes, Jane; Brenner, Maria; Fox, Patricia; Guerin, Ashleigh
2014-05-01
To report a novel review to develop a health systems model of successful transition of children with complex healthcare needs from hospital to home. Children with complex healthcare needs commonly experience an expensive, ineffectual and prolonged nurse-led discharge process. Children gain no benefit from prolonged hospitalization and are exposed to significant harm. Research to enable intervention development and process evaluation across the entire health system is lacking. Novel mixed-method integrative review informed by health systems theory. DATA CINAHL, PsychInfo, EMBASE, PubMed, citation searching, personal contact. REVIEW Informed by consultation with experts. English language studies, opinion/discussion papers reporting research, best practice and experiences of children, parents and healthcare professionals and purposively selected policies/guidelines from 2002-December 2012 were abstracted using Framework synthesis, followed by iterative theory development. Seven critical factors derived from thirty-four sources across five health system levels explained successful discharge (new programme theory). All seven factors are required in an integrated care pathway, with a dynamic communication loop to facilitate effective discharge (new programme logic). Current health system responses were frequently static and critical success factors were commonly absent, thereby explaining ineffectual discharge. The novel evidence-based model, which reconceptualizes 'discharge' as a highly complex longitudinal health system intervention, makes a significant contribution to global knowledge to drive practice development. Research is required to develop process and outcome measures at different time points in the discharge process and future trials are needed to determine the effectiveness of integrated health system discharge models. © 2013 John Wiley & Sons Ltd.
Hensel, Karol; Kučerová, Katarína; Tarabová, Barbora; Janda, Mário; Machala, Zdenko; Sano, Kaori; Mihai, Cosmin Teodor; Ciorpac, Mitică; Gorgan, Lucian Dragos; Jijie, Roxana; Pohoata, Valentin; Topala, Ionut
2015-06-06
Atmospheric pressure DC-driven self-pulsing transient spark (TS) discharge operated in air and pulse-driven dielectric barrier discharge plasma jet (PJ) operated in helium in contact with water solutions were used for inducing chemical effects in water solutions, and the treatment of bacteria (Escherichia coli), mammalian cells (Vero line normal cells, HeLa line cancerous cells), deoxyribonucleic acid (dsDNA), and protein (bovine serum albumin). Two different methods of water solution supply were used in the TS: water electrode system and water spray system. The effects of both TS systems and the PJ were compared, as well as a direct exposure of the solution to the discharge with an indirect exposure to the discharge activated gas flow. The chemical analysis of water solutions was performed by using colorimetric methods of UV-VIS absorption spectrophotometry. The bactericidal effects of the discharges on bacteria were evaluated by standard microbiological plate count method. Viability, apoptosis and cell cycle were assessed in normal and cancerous cells. Viability of cells was evaluated by trypan blue exclusion test, apoptosis by Annexin V-FITC/propidium iodide assay, and cell cycle progression by propidium iodide/RNase test. The effect of the discharges on deoxyribonucleic acid and protein were evaluated by fluorescence and UV absorption spectroscopy. The results of bacterial and mammalian cell viability, apoptosis, and cell cycle clearly show that cold plasma can inactivate bacteria and selectively target cancerous cells, which is very important for possible future development of new plasma therapeutic strategies in biomedicine. The authors found that all investigated bio-effects were stronger with the air TS discharge than with the He PJ, even in indirect exposure.
Partial Discharge Ultrasound Detection Using the Sagnac Interferometer System
Li, Xiaomin; Gao, Yan; Zhang, Hongjuan; Wang, Dong; Jin, Baoquan
2018-01-01
Partial discharge detection is crucial for electrical cable safety evaluation. The ultrasonic signals frequently generated in the partial discharge process contains important characteristic information. However, traditional ultrasonic transducers are easily subject to strong electromagnetic interference in environments with high voltages and strong magnetic fields. In order to overcome this problem, an optical fiber Sagnac interferometer system is proposed for partial discharge ultrasound detection. Optical fiber sensing and time-frequency analysis of the ultrasonic signals excited by the piezoelectric ultrasonic transducer is realized for the first time. The effective frequency band of the Sagnac interferometer system was up to 175 kHz with the help of a designed 10 kV partial discharge simulator device. Using the cumulative histogram method, the characteristic ultrasonic frequency band of the partial discharges was between 28.9 kHz and 57.6 kHz for this optical fiber partial discharge detection system. This new ultrasound sensor can be used as an ideal ultrasonic source for the intrinsically safe detection of partial discharges in an explosive environment. PMID:29734682
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Ben; He, Feng; Ouyang, Jiting, E-mail: jtouyang@bit.edu.cn
2015-12-15
Simulation work is very important for understanding the formation of self-organized discharge patterns. Previous works have witnessed different models derived from other systems for simulation of discharge pattern, but most of these models are complicated and time-consuming. In this paper, we introduce a convenient phenomenological dynamic model based on the basic dynamic process of glow discharge and the voltage transfer curve (VTC) to study the dielectric barrier glow discharge (DBGD) pattern. VTC is an important characteristic of DBGD, which plots the change of wall voltage after a discharge as a function of the initial total gap voltage. In the modeling,more » the combined effect of the discharge conditions is included in VTC, and the activation-inhibition effect is expressed by a spatial interaction term. Besides, the model reduces the dimensionality of the system by just considering the integration effect of current flow. All these greatly facilitate the construction of this model. Numerical simulations turn out to be in good accordance with our previous fluid modeling and experimental result.« less
40 CFR 125.64 - Effect of the discharge on other point and nonpoint sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Effect of the discharge on other point... (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Criteria for Modifying the Secondary Treatment Requirements Under Section 301(h) of the Clean Water Act...
40 CFR 125.64 - Effect of the discharge on other point and nonpoint sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Effect of the discharge on other point... (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Criteria for Modifying the Secondary Treatment Requirements Under Section 301(h) of the Clean Water Act...
40 CFR 125.64 - Effect of the discharge on other point and nonpoint sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 22 2014-07-01 2013-07-01 true Effect of the discharge on other point... (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Criteria for Modifying the Secondary Treatment Requirements Under Section 301(h) of the Clean Water Act...
40 CFR 125.64 - Effect of the discharge on other point and nonpoint sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Effect of the discharge on other point... (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Criteria for Modifying the Secondary Treatment Requirements Under Section 301(h) of the Clean Water Act...
40 CFR 125.64 - Effect of the discharge on other point and nonpoint sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 23 2013-07-01 2013-07-01 false Effect of the discharge on other point... (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Criteria for Modifying the Secondary Treatment Requirements Under Section 301(h) of the Clean Water Act...
Framework and components for effective discharge planning system: a delphi methodology
2012-01-01
Background To reduce avoidable hospital readmissions, effective discharge planning and appropriate post discharge support care are key requirements. This study is a 3-staged process to develop, pretest and pilot a framework for an effective discharge planning system in Hong Kong. This paper reports on the methodology of Delphi approach and findings of the second stage on pre-testing the framework developed so as to validate and attest to its applicability and practicability in which consensus was sought on the key components of discharge planning. Methods Delphi methodology was adopted to engage a group of experienced healthcare professionals to rate and discuss the framework and components of an effective discharge planning. The framework was consisted 36 statements under 5 major themes: initial screening, discharge planning process, coordination of discharge, implementation of discharge, and post discharge follow-up. Each statement was rated independently based on 3 aspects including clarity, validity and applicability on a 5-point Likert-scale. Statement with 75% or above of participants scoring 4–5 on all 3 aspects would be included in the discharge planning framework. For those statements not reaching 75% of consensus in any one of the aspect, it would be revised or discarded following the group discussion, and be re-rated in another round. Results A total of 24 participants participated in the consensus-building process. In round one rating, consensus was achieved in 25 out of 36 statements. Among those 11 statements not reaching consensus, the major concern was related to the “applicability” of the statements. The participants expressed a lack of manpower, skills and time in particular during weekends and long holidays in carrying out assessment and care plans within 24 h after admission. There were also timeliness and availability issue in providing transportation and necessary equipment to the patients. To make the statements more applicable, the wordings of some of the statements were revised to provide greater flexibility. Due to the lack of a statement in clarifying the role of the members of the healthcare professional team, one additional statement on the role and responsibility of the multidisciplinary team members was added. The first theme on “initial screening” was further revised to “initial screening and assessment” to better reflect the first stage of discharge planning process. After two rounds of rating process, all the 36 statements and the newly added statement reached consensus Conclusions A structured, systematic and coordinated system of hospital discharge system is required to facilitate the discharge process to ensure a smooth patient transition from the hospital to the community and improve patient health outcome in both clinical and social aspect. The findings of this paper provide a reference framework helping policymakers and hospital managers to facilitate the development of a coherent and systematized discharge planning process. Adopting a Delphi approach also demonstrates the values of the method as a pre-test (before the clinical run) of the components and requirements of a discharge planning system taking into account of the local context and system constraints, which would lead to improvements to its applicability and practicability. To confirm the applicability and practicability of this consensus framework for discharge planning system, the third stage of process of development of the discharge planning framework is to apply and pilot the framework in a hospital setting to evaluate its feasibility, applicability and impact in hospital including satisfaction from both the perspectives of staff and patients. PMID:23151173
Design methods, selection, and cost-effectiveness of stormwater quality structures
DOT National Transportation Integrated Search
2000-11-01
Implementation of the National Pollutant Discharge Elimination System (NPDES) and Texas Pollutant : Discharge Elimination System (TPDES) requires that the Texas Department of Transportation (TxDOT) : adopt a variety of stormwater quality measures to ...
Potential efficiencies of open- and closed-cycle CO, supersonic, electric-discharge lasers
NASA Technical Reports Server (NTRS)
Monson, D. J.
1976-01-01
Computed open- and closed-cycle system efficiencies (laser power output divided by electrical power input) are presented for a CW carbon monoxide, supersonic, electric-discharge laser. Closed-system results include the compressor power required to overcome stagnation pressure losses due to supersonic heat addition and a supersonic diffuser. The paper shows the effect on the system efficiencies of varying several important parameters. These parameters include: gas mixture, gas temperature, gas total temperature, gas density, total discharge energy loading, discharge efficiency, saturated gain coefficient, optical cavity size and location with respect to the discharge, and supersonic diffuser efficiency. Maximum open-cycle efficiency of 80-90% is predicted; the best closed-cycle result is 60-70%.
Investigation of flame structure in plasma-assisted turbulent premixed methane-air flame
NASA Astrophysics Data System (ADS)
Hualei, ZHANG; Liming, HE; Jinlu, YU; Wentao, QI; Gaocheng, CHEN
2018-02-01
The mechanism of plasma-assisted combustion at increasing discharge voltage is investigated in detail at two distinctive system schemes (pretreatment of reactants and direct in situ discharge). OH-planar laser-induced fluorescence (PLIF) technique is used to diagnose the turbulent structure methane-air flame, and the experimental apparatus consists of dump burner, plasma-generating system, gas supply system and OH-PLIF system. Results have shown that the effect of pretreatment of reactants on flame can be categorized into three regimes: regime I for voltage lower than 6.6 kV; regime II for voltage between 6.6 and 11.1 kV; and regime III for voltage between 11.1 and 12.5 kV. In regime I, aerodynamic effect and slower oxidation of higher hydrocarbons generated around the inner electrode tip plays a dominate role, while in regime III, the temperature rising effect will probably superimpose on the chemical effect and amplify it. For wire-cylinder dielectric barrier discharge reactor with spatially uneven electric field, the amount of radicals and hydrocarbons are decreased monotonically in radial direction which affects the flame shape. With regard to in situ plasma discharge in flames, the discharge pattern changes from streamer type to glow type. Compared with the case of reactants pretreatment, the flame propagates further in the upstream direction. In the discharge region, the OH intensity is highest for in situ plasma assisted combustion, indicating that the plasma energy is coupled into flame reaction zone.
Health effects of Halon 1301 exposure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holness, D.L.; House, R.A.
1992-07-01
An accidental discharge of a Halon 1301 system is reported. Thirty-one workers were assessed, 22 who were present at the time of the discharge, and 9 who worked the next shift. The incident was complicated by a small Freon-22 leak several hours later. Throat, eye, and nasal irritation and lightheadedness were reported by the majority of workers. Workers present during the halon discharge reported significantly more lightheadedness, headache, voice change, cough, and a fast heartbeat than did those who worked the later shift. These differences were significant even after correcting for confounding factors such as age, sex, and sense ofmore » anxiety at the time of the incident. The possible causes for the irritant symptoms include breakdown products of Halon 1301 and Freon-22 or contaminants from the halon discharge system. Although these irritant effects may not be an effect of Halon 1301 alone, they may occur in these discharge situations, and workers should be advised of this possibility. The possible cardiac and central nervous system effects also should be considered. The importance of a clear-cut protocol to deal with such incidents as well as worker education are discussed.« less
[Spectral diagnosis of hydroxyl radical in multiphase pulsed discharge system].
Wang, Hui-juan; Li, Jie; Quan, Xie; Wu, Yan; Li, Guo-feng
2007-12-01
A gas-liquid hybrid pulsed discharge system with a multi-needle-to-plate electrode geometry was used in the present study. A multiphase (gas-liquid-solid) pulsed discharge system was then formed by adding glasses beads immobilized with TiO2 photocatalyst into the discharge system. In the present paper, ultraviolet light produced during the pulsed discharge process was used as the lamp-house to induce the photocatalytic activity of the TiO2 photocatalyst. The synergistic effect of pulsed discharge and TiO2 photocatalysis was reviewed by the spectral diagnosis of hydroxyl radical ( *OH) in the pulsed discharge system. The obtained results showed that the emission spectrum of *OH could be observed at 306 nm (A2Sigma+-->X2II), 309 mn (A2Sigma+ (v' = 0) --> X2II (v" = 0)) and 313 nm (A2Sigma+ (v' = 1) --> X2II (v" = 1) transition). The relative emission intensity of *OH at 313 nm in the discharge system was the strongest among the three characteristic spectra. The relative emission intensity of *OH at 313 nm was stronger by adding TiO2 photocatalyst into the pulsed discharge system than that in the sole pulsed discharge system. In the case of experiments that changing the gas bubbling varieties and initial solution pH values, the results revealed that the relative emission intensity of *OH at 313 nm in the synergistic system was stronger when Ar was used as bubbling gas compared with that when air and oxygen were bubbled into the reaction system. Furthermore, the acidic solution system was favorable for producing more *OH, and therefore the corresponding emission intensity of *OH at 313 nm was stronger than that in the neutral and basic solution.
Williams, Donald R.; Sams, James I.; Mulkerrin, Mary E.
1996-01-01
This report describes the results of a study by the U.S. Geological Survey, done in cooperation with the Somerset Conservation District, to locate and sample abandoned coal-mine discharges in the Stonycreek River Basin, to prioritize the mine discharges for remediation, and to determine the effects of the mine discharges on water quality of the Stonycreek River and its major tributaries. From October 1991 through November 1994, 270 abandoned coal-mine discharges were located and sampled. Discharges from 193 mines exceeded U.S. Environmental Protection Agency effluent standards for pH, discharges from 122 mines exceeded effluent standards for total-iron concentration, and discharges from 141 mines exceeded effluent standards for total-manganese concentration. Discharges from 94 mines exceeded effluent standards for all three constituents. Only 40 mine discharges met effluent standards for pH and concentrations of total iron and total manganese.A prioritization index (PI) was developed to rank the mine discharges with respect to their loading capacity on the receiving stream. The PI lists the most severe mine discharges in a descending order for the Stonycreek River Basin and for subbasins that include the Shade Creek, Paint Creek, Wells Creek, Quemahoning Creek, Oven Run, and Pokeytown Run Basins.Passive-treatment systems that include aerobic wetlands, compost wetlands, and anoxic limestone drains (ALD's) are planned to remediate the abandoned mine discharges. The successive alkalinity-producing-system treatment combines ALD technology with the sulfate reduction mechanism of the compost wetland to effectively remediate mine discharge. The water quality and flow of each mine discharge will determine which treatment system or combination of treatment systems would be necessary for remediation.A network of 37 surface-water sampling sites was established to determine stream-water quality during base flow. A series of illustrations show how water quality in the mainstem deteriorates downstream because of inflows from tributaries affected by acidic mine discharges. From the upstream mainstem site (site 801) to the outflow mainstem site (site 805), pH decreased from 6.8 to 4.2, alkalinity was completely depleted by inflow acidities, and total-iron discharges increased from 30 to 684 pounds per day. Total-manganese and total-sulfate discharges increased because neither constituent precipitates readily. Also, discharges of manganese and sulfate entering the mainstem from tributary streams have a cumulative effect.Oven Run and Pokeytown Run are two small tributary streams significantly affected by acidic mine drainage (AMD) that flow into the Stonycreek River near the town of Hooversville. The Pokeytown Run inflow is about 0.5 mile downstream from the Oven Run inflow. These two streams are the first major source of AMD flowing into the Stonycreek River. Data collected on the Stonycreek River above the Oven Run inflow and below the Pokeytown Run inflow show a decrease in pH from 7.6 to 5.1, a decrease in alkalinity concentration from 42 to 2 milligrams per liter, an increase in total sulfate discharge from 18 to 41 tons per day, and an increase in total iron discharge from 29 to 1,770 pounds per day. Data collected at three mainstem sites on the Stonycreek River below Oven Run and Pokeytown Run show a progressive deterioration in river water quality from AMD.Shade Creek and Paint Creek are other tributary streams to the Stonycreek River that have a significant negative effect on water quality of the Stonycreek River. One third of the abandoned-mine discharges sampled were in the Shade Creek and Paint Creek Basins.
Tsuzuki, Y; Koottatep, T; Jiawkok, S; Saengpeng, S
2010-01-01
In developing countries with large Millennium Development Goals (MDGs) sanitation indicator, pollutant discharge reduction function of wastewater treatment systems should be considered. In this paper, pollutant generations per capita (PGCs) and pollutant discharges per capita (PDCs) are estimated as a base dataset for wastewater management in Thailand. PDCs of black water, i.e. toilet wastewater, are found to be much smaller than PGCs of black water. However, PDCs of gray water, i.e. municipal wastewater other than toilet wastewater are large. Gray water is often discharged without treatment and contributes much to ambient water deterioration. Moreover, possible 5-day biological oxygen demand (BOD5) discharge reductions with "soft interventions", i.e. measurements in households to reduce wastewater pollutant discharge such as using a paper filter or a plastic net in kitchen sinks and so on, are estimated as 39, 21 and 34% for BOD5, total Kjeldahl nitrogen (TKN) and phosphate (PO4-P), respectively. For the estimation, environmental accounting housekeeping (EAH) books of domestic wastewater, spreadsheets with pollutant discharges by water usages and possible effects of "soft interventions" are applied. The framework of this study with "soft intervention" effects on pollutant discharge reductions should enhance wastewater management especially in the areas under development of wastewater treatment systems.
NASA Astrophysics Data System (ADS)
Zhu, Xinlei; Zhang, Liancheng; Huang, Yifan; Wang, Jin; Liu, Zhen; Yan, Keping
2017-07-01
A new sparker system based on pulsed spark discharge with a single electrode has already been utilized for oceanic seismic exploration. However, the electro-acoustic energy efficiency of this system is lower than that of arc discharge based systems. A simple electrode structure was investigated in order to improve the electro-acoustic energy efficiency of the spark discharge. Experiments were carried out on an experimental setup with discharge in water driven by a pulsed power source. The voltage-current waveform, acoustic signal and bubble oscillation were recorded when the relative position of the electrode varied. The electro-acoustic energy efficiency was also calculated. The load voltage had a saltation for the invaginated electrode tip, namely an obvious voltage remnant. The more the electrode tip was invaginated, the larger the pressure peaks and first period became. The results show that electrode recessing into the insulating layer is a simple and effective way to improve the electro-acoustic energy efficiency from 2% to about 4%.
Assessing the Effects of Climate on Global Fluvial Discharge Variability
NASA Astrophysics Data System (ADS)
Hansford, M. R.; Plink-Bjorklund, P.
2017-12-01
Plink-Bjorklund (2015) established the link between precipitation seasonality and river discharge variability in the monsoon domain and subtropical rivers (see also Leier et al, 2005; Fielding et al., 2009), resulting in distinct morphodynamic processes and a sedimentary record distinct from perennial precipitation zone in tropical rainforest zone and mid latitudes. This study further develops our understanding of discharge variability using a modern global river database created with data from the Global Runoff Data Centre (GRDC). The database consists of daily discharge for 595 river stations and examines them using a series of discharge variability indexes (DVI) on different temporal scales to examine how discharge variability occurs in river systems around the globe. These indexes examine discharge of individual days and monthly averages that allows for comparison of river systems against each other, regardless of size of the river. Comparing river discharge patterns in seven climate zones (arid, cold, humid subtropics, monsoonal, polar, rainforest, and temperate) based off the Koppen-Geiger climate classifications reveals a first order climatic control on discharge patterns and correspondingly sediment transport. Four groupings of discharge patterns emerge when coming climate zones and DVI: persistent, moderate, seasonal, and erratic. This dataset has incredible predictive power about the nature of discharge in fluvial systems around the world. These seasonal effects on surface water supply affects river morphodynamics and sedimentation on a wide timeframe, ranging from large single events to an inter-annual or even decadal timeframe. The resulting sedimentary deposits lead to differences in fluvial architecture on a range of depositional scales from sedimentary structures and bedforms to channel complex systems. These differences are important to accurately model for several reasons, ranging from stratigraphic and paleoenviromental reconstructions to more economic reasons, such as predicting reservoir presence, distribution, and connectivity in continental basins. The ultimate objective of this research is to develop differentiated fluvial facies and architecture based on the observed discharge patterns in the different climate zones.
Yield of H2O2 in Gas-Liquid Phase with Pulsed DBD
NASA Astrophysics Data System (ADS)
Jiang, Song; Wen, Yiyong; Liu, Kefu
2014-01-01
Electric discharge in water can generate a large number of oxidants such as ozone, hydrogen peroxide and hydroxyl radicals. In this paper, a non-thermal plasma processing system was established by means of pulsed dielectric barrier discharge in gas-liquid phase. The electrodes of discharge reactor were staggered. The yield of H2O2 was enhanced after discharge. The effects of discharge time, discharge voltage, frequency, initial pH value, and feed gas were investigated. The concentration of hydrogen peroxide and ozone was measured after discharge. The experimental results were fully analyzed. The chemical reaction equations in water were given as much as possible. At last, the water containing Rhodamine B was tested in this system. The degradation rate came to 94.22% in 30 min.
NASA Technical Reports Server (NTRS)
Gelalles, A G; Marsh, E T
1933-01-01
Using the method of weighing fuel collected in a receiver during a definite interval of the injection period, rates of discharge were determined, and the effects noted, when various changes were made in a fuel-injection system. The injection system consisted primarily of a by-pass controlled fuel pump and an automatic injection valve. The variables of the system studied were the pump speed, pump-throttle setting, discharge-orifice diameter, injection-valve opening and closing pressures, and injection-tube length and diameter.
NASA Technical Reports Server (NTRS)
Rothrock, A M; Lee, D W
1932-01-01
Tests were made to determine the effect of the reservoir volume on the discharge pressures in the injection system of the N.A.C.A. spray photography equipment. The data obtained are applicable to the design of a common rail fuel-injection system. The data show that an injection system of the type described can be designed so that not more than full load fuel quantity can be injected into the engine cylinders, and so that the fuel spray characteristics remain constant over a large range of engine speeds. Formulas are presented for computing the volume of the reservoir and the diameter of the discharge orifice.
Degradation of imidacloprid in wastewater by dielectric barrier discharge system
NASA Astrophysics Data System (ADS)
Li, Kebin
2018-03-01
The degradation behavior of imidacloprid in wastewater was investigated with dielectric barrier discharge (DBD) system and the effect of several factors that could influence degradation process was explored in this study. The study showed that imidacloprid could be effectively removed by DBD system under certain conditions. The optimal removal efficiency was 75.6% when applied voltage was 75 V and 160 min was selected as the discharge time. Moreover, lower conductivity and alkaline environment were favorable for the imidacloprid degradation. The presence of Cu2+ and Fe2+ could benefit for the imidacloprid degradation, however the catalytic effect of Cu2+ was lower than that of Fe2+. Furthermore, methanol as scavenger decreased the removal efficiency of imidacloprid owing to the scavenger inhibited the generation of hydroxyl radicals during the DBD process.
Auto-Detection of Partial Discharges in Power Cables by Descrete Wavelet Transform
NASA Astrophysics Data System (ADS)
Yasuda, Yoh; Hara, Takehisa; Urano, Koji; Chen, Min
One of the serious problems that may happen in power XLPE cables is destruction of insulator. The best and conventional way to prevent such a crucial accident is generally supposed to ascertain partial corona discharges occurring at small void in organic insulator. However, there are some difficulties to detect those partial discharges because of existence of external noises in detected data, whose patterns are hardly identified at a glance. By the reason of the problem, there have been a number of researches on the way of development to accomplish detecting partial discharges by employing neural network (NN) system, which is widely known as the system for pattern recognition. We have been developing the NN system of the auto-detection for partial discharges, which we actually input numerical data of waveform itself into and obtained appropriate performance from. In this paper, we employed Descrete Wavelet Transform (DWT) to acquire more detailed transformed data in order to put them into the NN system. Employing DWT, we became able to express the waveform data in time-frequency space, and achieved effective detectiton of partial discharges by NN system. We present here the results using DWT analysis for partial discharges and noise signals which we obtained actually. Moreover, we present results out of the NN system which were dealt with those transformed data.
Patient experience with discharge instructions in postdischarge recovery: a qualitative study.
Horstman, Molly J; Mills, Whitney L; Herman, Levi I; Cai, Cecilia; Shelton, George; Qdaisat, Tareq; Berger, David H; Naik, Aanand D
2017-02-22
We examined the role of discharge instructions in postoperative recovery for patients undergoing colorectal surgery and report themes related to patient perceptions of discharge instructions and postdischarge experience. Semistructured interviews were conducted as part of a formative evaluation of a Project Re-Engineered Discharge intervention adapted for surgical patients. Michael E. DeBakey VA Medical Center, a tertiary referral centre in Houston, Texas. Twelve patients undergoing elective colorectal surgery. Interviews were conducted at the two-week postoperative appointment. Participants demonstrated understanding of the content in the discharge instructions. During the interviews, participants reported several positive roles for discharge instructions in their postdischarge care: a sense of security, a reminder of inhospital education, a living document and a source of empowerment. Despite these positive associations, participants reported that the instructions provided insufficient information to promote access to care that effectively addressed acute issues following discharge. Participants noted difficulty reaching providers after discharge, which resulted in the adoption of workarounds to overcome system barriers. Despite concerted efforts to provide patient-centred instructions, the discharge instructions did not provide enough context to effectively guide postdischarge interactions with the healthcare system. Insufficient information on how to access and communicate with the most appropriate personnel in the healthcare system is an important barrier to patients receiving high-quality postdischarge care. Tools and strategies from team training programmes, such as team strategies and tools to enhance performance and patient safety, could be adapted to include patients and provide them with structured methods for communicating with healthcare providers post discharge. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
46 CFR 76.23-10 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 76.23-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-10 Quantity, pipe sizes, and discharge rates. (a) General. (1) The system shall be so designed and arranged that the overhead is effectively...
46 CFR 76.23-10 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 76.23-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-10 Quantity, pipe sizes, and discharge rates. (a) General. (1) The system shall be so designed and arranged that the overhead is effectively...
46 CFR 76.23-10 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 76.23-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-10 Quantity, pipe sizes, and discharge rates. (a) General. (1) The system shall be so designed and arranged that the overhead is effectively...
46 CFR 76.23-10 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 76.23-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-10 Quantity, pipe sizes, and discharge rates. (a) General. (1) The system shall be so designed and arranged that the overhead is effectively...
46 CFR 76.23-10 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 76.23-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Sprinkling System, Details § 76.23-10 Quantity, pipe sizes, and discharge rates. (a) General. (1) The system shall be so designed and arranged that the overhead is effectively...
An experimental system for controlled exposure of biological samples to electrostatic discharges.
Marjanovič, Igor; Kotnik, Tadej
2013-12-01
Electrostatic discharges occur naturally as lightning strokes, and artificially in light sources and in materials processing. When an electrostatic discharge interacts with living matter, the basic physical effects can be accompanied by biophysical and biochemical phenomena, including cell excitation, electroporation, and electrofusion. To study these phenomena, we developed an experimental system that provides easy sample insertion and removal, protection from airborne particles, observability during the experiment, accurate discharge origin positioning, discharge delivery into the sample either through an electric arc with adjustable air gap width or through direct contact, and reliable electrical insulation where required. We tested the system by assessing irreversible electroporation of Escherichia coli bacteria (15 mm discharge arc, 100 A peak current, 0.1 μs zero-to-peak time, 0.2 μs peak-to-halving time), and gene electrotransfer into CHO cells (7 mm discharge arc, 14 A peak current, 0.5 μs zero-to-peak time, 1.0 μs peak-to-halving time). Exposures to natural lightning stroke can also be studied with this system, as due to radial current dissipation, the conditions achieved by a stroke at a particular distance from its entry are also achieved by an artificial discharge with electric current downscaled in magnitude, but similar in time course, correspondingly closer to its entry. © 2013.
Khanna, Sankalp; Boyle, Justin; Good, Norm; Lind, James
2012-10-01
To investigate the effect of hospital occupancy levels on inpatient and ED patient flow parameters, and to simulate the impact of shifting discharge timing on occupancy levels. Retrospective analysis of hospital inpatient data and ED data from 23 reporting public hospitals in Queensland, Australia, across 30 months. Relationships between outcome measures were explored through the aggregation of the historic data into 21 912 hourly intervals. Main outcome measures included admission and discharge rates, occupancy levels, length of stay for admitted and emergency patients, and the occurrence of access block. The impact of shifting discharge timing on occupancy levels was quantified using observed and simulated data. The study identified three stages of system performance decline, or choke points, as hospital occupancy increased. These choke points were found to be dependent on hospital size, and reflect a system change from 'business-as-usual' to 'crisis'. Effecting early discharge of patients was also found to significantly (P < 0.001) impact overcrowding levels and improve patient flow. Modern hospital systems have the ability to operate efficiently above an often-prescribed 85% occupancy level, with optimal levels varying across hospitals of different size. Operating over these optimal levels leads to performance deterioration defined around occupancy choke points. Understanding these choke points and designing strategies around alleviating these flow bottlenecks would improve capacity management, reduce access block and improve patient outcomes. Effecting early discharge also helps alleviate overcrowding and related stress on the system. © 2012 CSIRO. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Modified PADSS (Post Anaesthetic Discharge Scoring System) for monitoring outpatients discharge.
Palumbo, Piergaspare; Tellan, Guglielmo; Perotti, Bruno; Pacilè, Maria Antonietta; Vietri, Francesco; Illuminati, Giulio
2013-01-01
The decision to discharge a patient undergoing day surgery is a major step in the hospitalization pathway, because it must be achieved without compromising the quality of care, thus ensuring the same assistance and wellbeing as for a long-term stay. Therefore, the use of an objective assessment for the management of a fair and safe discharge is essential. The authors propose the Post Anaesthetic Discharge Scoring System (PADSS), which considers six criteria: vital signs, ambulation, nausea/vomiting, pain, bleeding and voiding. Each criterion is given a score ranging from 0 to 2. Only patients who achieve a score of 9 or more are considered ready for discharge. Furthermore, PADSS has been modified to ensure a higher level of safety, thus the "vital signs" criteria must never score lower than 2, and none of the other five criteria must ever be equal to 0, even if the total score reaches 9. The effectiveness of PADSS was analyzed on 2432 patients, by recording the incidence of postoperative complications and the readmission to hospital. So far PADDS has proved to be an efficient system that guarantees safe discharge.
Liang, Peng; Wu, Wenlong; Wei, Jincheng; Yuan, Lulu; Xia, Xue; Huang, Xia
2011-08-01
A bioelectrochemical system (BES) can be operated in both "microbial fuel cell" (MFC) and "microbial electrolysis cell" (MEC) modes, in which power is delivered and invested respectively. To enhance the electric current production, a BES was operated in MFC mode first and a capacitor was used to collect power from the system. Then the charged capacitor discharged electrons to the system itself, switching into MEC mode. This alternate charging and discharging (ACD) mode helped the system produce 22-32% higher average current compared to an intermittent charging (IC) mode, in which the capacitor was first charged from an MFC and then discharged to a resistor, at 21.6 Ω external resistance, 3.3 F capacitance and 300 mV charging voltage. The effects of external resistance, capacitance and charging voltage on average current were studied. The average current reduced as the external resistance and charging voltage increased and was slightly affected by the capacitance. Acquisition of higher average current in the ACD mode was attributed to the shorter discharging time compared to the charging time, as well as a higher anode potential caused by discharging the capacitor. Results from circuit analysis and quantitatively calculation were consistent with the experimental observations.
Bipolar and Monopolar Lithium-Ion Battery Technology at Yardney
NASA Technical Reports Server (NTRS)
Russell, P.; Flynn, J.; Reddy, T.
1996-01-01
Lithium-ion battery systems offer several advantages: intrinsically safe; long cycle life; environmentally friendly; high energy density; wide operating temperature range; good discharge rate capability; low self-discharge; and no memory effect.
Space platform power system hardware testbed
NASA Technical Reports Server (NTRS)
Sable, D.; Patil, A.; Sizemore, T.; Deuty, S.; Noon, J.; Cho, B. H.; Lee, F. C.
1991-01-01
The scope of the work on the NASA Space Platform includes the design of a multi-module, multi-phase boost regulator, and a voltage-fed, push-pull autotransformer converter for the battery discharger. A buck converter was designed for the charge regulator. Also included is the associated mode control electronics for the charger and discharger, as well as continued development of a comprehensive modeling and simulation tool for the system. The design of the multi-module boost converter is discussed for use as a battery discharger. An alternative battery discharger design is discussed using a voltage-fed, push-pull autotransformer converter. The design of the charge regulator is explained using a simple buck converter. The design of the mode controller and effects of locating the bus filter capacitor bank 20 feet away from the power ORU are discussed. A brief discussion of some alternative topologies for battery charging and discharging is included. The power system modeling is described.
He, Jiazhen; Lu, Yehu; Chen, Yan; Li, Jun
2017-09-15
In addition to direct thermal energy from a heating source, a large amount of thermal energy stored in clothing will continuously discharge to skin after exposure. Investigating the thermal hazardous effect of clothing caused by stored energy discharge is crucial for the reliability of thermal protective clothing. In this study several indices were proposed and applied to evaluate the impact of thermal energy discharge on human skin. The heat discharge from different layers of fabric systems was investigated, and the influences of air gaps and applied compression were examined. Heat fluxes at the boundaries of fabric layers and the distribution of heat discharge were determined. Additionally, the correlation between heat storage during exposure and heat discharge after exposure was identified. The results demonstrated that heat discharge to the skin could be correlated with heat storage within the fabric, however, it highly depended on the air gap under clothing, the applied compression, and the insulation provided by the fabric layers. Results from this study could contribute to thoroughly understanding the thermal hazardous effect of clothing and enhance the technical basis for developing new fabric combinations to minimize energy discharge after exposure. Copyright © 2017 Elsevier B.V. All rights reserved.
Occurrence of Volcanic CO2 by Groundwater Flow Systems in the Eifel Mountains, Germany
NASA Astrophysics Data System (ADS)
Weyer, K.; May, F.; Ellis, J. C.
2011-12-01
Weyer (2010) showed why and how discharge areas of regional groundwater flow systems are also discharge points of natural and stored CO2. As groundwater flow systems reach to great depth by penetrating aquitards and caprocks any successful design of on-shore geological carbon storage must regard the migration effects groundwater flow systems exert on stored CO2. Eventually all of the CO2 will be dissolved by groundwater and migrate to the discharge areas of these flow systems. By implication there will rarely be the anticipated permanent storage of CO2 in the subsurface. Instead the deep ground water flow will transport the dissolved CO2 into surface waters. A telling example of such a system is the Green River in Utah with its natural discharge points of volcanic CO2 and the artificial discharge point Crystal Geyser, a flowing abandoned well located at the bank of the Green River. The advantage of this situation is that there have been hydrogeological tools developed which allow the determination of the flow path of the groundwater flow systems and their approximate time scale to reach their groundwater discharge areas. These time spans may be as large as 50,000 to 100,000 years. In any case residence times of a thousand years and more would suffice in mitigating the atmospheric effect of CO2 discharge. The above concepts have so far not created much resonance in the scientific and practical world of geologic CO2 storage. Therefore the investigation of groundwater dynamics at areas with natural discharge of volcanic CO2 provides a test for the effect groundwater flow systems will exert on the geologic storage of CO2. The Eifel Mountains in Germany present such a natural laboratory as it contains over a hundred known Tertiary and Quaternary volcanoes. Its discharge points of water carrying CO2 are well-known as they have been used for generations for the production of carbonated mineral waters. For the western part of the Eifel-Mountains, May (2002) listed all known natural CO2 discharge points with coordinates. The high resolution digital topographical maps of the area outline the elevation of the groundwater table in these mountains as the topography controls the elevation of the groundwater table. The detailed network of rivers, creeks and lakes denotes the location of groundwater discharge areas draining into the surface waters. Büchel and Mertens (1982) provided the locations of volcanic eruption centers in the western part of the Eifel Mountains. After combining the above information in a series of small scale DEMs created with 'SURFER' it became directly obvious that all known natural CO2 discharge points are directly related to discharge areas while the occurrence of volcanic eruption centers is concentrated in the recharge areas for regional groundwater flow. Quod erat demonstrandum. Büchel, G., H. Mertes (1982). Die Eruptionszentren des Westeifeler Vulkanfeldes. Zeitschr. DGG, 131: 409-429. May, Franz (2002). Säuerlinge der Vulkaneifel und der Südeifel. Mainzer geowissen. Mitt., 31: 7-58. Weyer, K. U. (2010). Differing physical processes in off-shore and on-shore CO2 storage. Private publication based on a poster presented at GHGT-10, Amsterdam. 8 pp, July 2010.
Berenbrock, Charles
1993-01-01
substantially less in late summer than in the spring. A hydraulic head/spring discharge relation was developed for two sites at Indian Bathtub Spring and a nearby test hole. The relation for Indian Bathtub Spring indicated that a spring discharge of 2,400 gallons per minute would relate to a hydraulic head of about 2,708 feet at the spring, which is about 34 feet higher than the head at zero spring discharge.
CO2 Dissociation by Low Current Gliding Discharge in the Reverse Vortex Flow
NASA Astrophysics Data System (ADS)
Gutsol, Alexander
2012-10-01
If performed with high energy efficiency, plasma-chemical dissociation of carbon dioxide can be a way of converting and storing energy when there is an excess of electric energy, for example generated by solar elements of wind turbines. CO2 dissociation with efficiency of up to 90% was reported earlier for low pressure microwave discharge in supersonic flow. A new plasma-chemical system uses a low current gliding discharge in the reverse vortex flow of plasma gas. The system is a development of the Gliding Arc in Tornado reactor. The system was used to study dissociation of CO2 in wide ranges of the following experimental parameters: reactor pressure (15-150 kPa), discharge current (50-500 mA), gas flow rate (3-30 liters per minute), and electrode gap length (1-10 cm). Additionally, the effect of thermal energy recuperation on CO2 dissociation efficiency was tested. Plasma chemical efficiency of CO2 dissociation is very low (about 3%) in a short discharge at low pressures (about 15 kPa) when it is defined by electronic excitation. The highest efficiency (above 40%) was reached at pressures 50-70 kPa in a long discharge with thermal energy recuperation. It means that the process is controlled by thermal dissociation with subsequent effective quenching. Plasma chemical efficiency was determined from the data of chromatographic analysis and oscilloscope electric power integration, and also was checked calorimetrically by the thermal balance of the system.
Glow discharge plasma deposition of thin films
Weakliem, Herbert A.; Vossen, Jr., John L.
1984-05-29
A glow discharge plasma reactor for deposition of thin films from a reactive RF glow discharge is provided with a screen positioned between the walls of the chamber and the cathode to confine the glow discharge region to within the region defined by the screen and the cathode. A substrate for receiving deposition material from a reactive gas is positioned outside the screened region. The screen is electrically connected to the system ground to thereby serve as the anode of the system. The energy of the reactive gas species is reduced as they diffuse through the screen to the substrate. Reactive gas is conducted directly into the glow discharge region through a centrally positioned distribution head to reduce contamination effects otherwise caused by secondary reaction products and impurities deposited on the reactor walls.
A cost-effectiveness evaluation of hospital discharge counseling by pharmacists.
Chinthammit, Chanadda; Armstrong, Edward P; Warholak, Terri L
2012-04-01
This study estimated the cost-effectiveness of pharmacist discharge counseling on medication-related morbidity in both the high-risk elderly and general US population. A cost-effectiveness decision analytic model was developed using a health care system perspective based on published clinical trials. Costs included direct medical costs, and the effectiveness unit was patients discharged without suffering a subsequent adverse drug event. A systematic review of published studies was conducted to estimate variable probabilities in the cost-effectiveness model. To test the robustness of the results, a second-order probabilistic sensitivity analysis (Monte Carlo simulation) was used to run 10 000 cases through the model sampling across all distributions simultaneously. Pharmacist counseling at hospital discharge provided a small, but statistically significant, clinical improvement at a similar overall cost. Pharmacist counseling was cost saving in approximately 48% of scenarios and in the remaining scenarios had a low willingness-to-pay threshold for all scenarios being cost-effective. In addition, discharge counseling was more cost-effective in the high-risk elderly population compared to the general population. This cost-effectiveness analysis suggests that discharge counseling by pharmacists is quite cost-effective and estimated to be cost saving in over 48% of cases. High-risk elderly patients appear to especially benefit from these pharmacist services.
System for Measuring Conditional Amplitude, Phase, or Time Distributions of Pulsating Phenomena
Van Brunt, Richard J.; Cernyar, Eric W.
1992-01-01
A detailed description is given of an electronic stochastic analyzer for use with direct “real-time” measurements of the conditional distributions needed for a complete stochastic characterization of pulsating phenomena that can be represented as random point processes. The measurement system described here is designed to reveal and quantify effects of pulse-to-pulse or phase-to-phase memory propagation. The unraveling of memory effects is required so that the physical basis for observed statistical properties of pulsating phenomena can be understood. The individual unique circuit components that comprise the system and the combinations of these components for various measurements, are thoroughly documented. The system has been applied to the measurement of pulsating partial discharges generated by applying alternating or constant voltage to a discharge gap. Examples are shown of data obtained for conditional and unconditional amplitude, time interval, and phase-of-occurrence distributions of partial-discharge pulses. The results unequivocally show the existence of significant memory effects as indicated, for example, by the observations that the most probable amplitudes and phases-of-occurrence of discharge pulses depend on the amplitudes and/or phases of the preceding pulses. Sources of error and fundamental limitations of the present measurement approach are analyzed. Possible extensions of the method are also discussed. PMID:28053450
Residuals Charges for Pollution Control: A Policy Evaluation
ERIC Educational Resources Information Center
Freeman, A. Myrick, III; Haveman, Robert H.
1972-01-01
Contrasts the effects of a policy of regulation of pollutant discharge by enforcement of a permit system with the likely consequences of a policy of charging for effluents, thus increasing the cost of discharge. The charge for residuals is favored, and it is suggested that trials of the system be conducted, perhaps with a federal tax on emission…
Characteristics of a corona discharge with a hot corona electrode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulumbaev, E. B.; Lelevkin, V. M.; Niyazaliev, I. A.
The effect of the temperature of the corona electrode on the electrical characteristics of a corona discharge was studied experimentally. A modified Townsend formula for the current-voltage characteristic of a one-dimensional corona is proposed. Gasdynamic and thermal characteristics of a positive corona discharge in a coaxial electrode system are calculated. The calculated results are compared with the experimental data.
Effects of arcing due to spacecraft charging on spacecraft survival
NASA Technical Reports Server (NTRS)
Rosen, A.; Sanders, N. L.; Ellen, J. M., Jr.; Inouye, G. T.
1978-01-01
A quantitative assessment of the hazard associated with spacecraft charging and arcing on spacecraft systems is presented. A literature survey on arc discharge thresholds and characteristics was done and gaps in the data and requirements for additional experiments were identified. Calculations of coupling of arc discharges into typical spacecraft systems were made and the susceptibility of typical spacecraft to disruption by arc discharges was investigated. Design guidelines and recommended practices to reduce or eliminate the threat of malfunction and failures due to spacecraft charging/arcing were summarized.
Design and research on discharge performance for aluminum-air battery
NASA Astrophysics Data System (ADS)
Liu, Zu; Zhao, Junhong; Cai, Yanping; Xu, Bin
2017-01-01
As a kind of clean energy, the research of aluminum air battery is carried out because aluminum-air battery has advantages of high specific energy, silence and low infrared. Based on the research on operating principle of aluminum-air battery, a novel aluminum-air battery system was designed composed of aluminum-air cell and the circulation system of electrolyte. A system model is established to analyze the polarization curve, the constant current discharge performance and effect of electrolyte concentration on the performance of monomer. The experimental results show that the new energy aluminum-air battery has good discharge performance, which lays a foundation for its application.
Report #2007-P-00023, May 14, 2007. EPA did not provide effective enforcement oversight of major facilities with National Pollutant Discharge Elimination System permits in long-term significant noncompliance.
NASA Astrophysics Data System (ADS)
Pucci, Amleto A.; Pope, Daryll A.
1995-05-01
Stream flow in the Coastal Plain of New Jersey is primarily controlled by ground-water discharge. Ground-water flow in a 400 square mile area (1035 km 2) of the Potomac-Raritan-Magothy aquifer system (PRMA) in the northern Coastal Plain of New Jersey was simulated to examine development effects on water resources. Simulations showed that historical development caused significant capture of regional ground-water discharge to streams and wetlands. The Cretaceous PRMA primarily is composed of fine to coarse sand, clays and silts which form the Upper and Middle aquifers and their confining units. The aquifer outcrops are the principal areas of recharge and discharge for the regional flow system and have many traversing streams and surface-water bodies. A quasi-three-dimensional numerical model that incorporated ground-water/surface-water interactions and boundary flows from a larger regional model was used to represent the PRMA. To evaluate the influence of ground-water development on interactions in different areas, hydrogeologically similar and contiguous model stream cells were aggregated as 'stream zones'. The model representation of surface-water and ground-water interaction was limited in the areas of confining unit outcrops and because of this, simulated ground-water discharge could not be directly compared with base flow. Significant differences in simulated ground-water and surface-water interactions between the predevelopment and developed system, include; (1) redistribution of recharge and discharge areas; (2) reduced ground-water discharge to streams. In predevelopment, the primary discharge for the Upper and Middle aquifers is to low-lying streams and wetlands; in the developed system, the primary discharge is to ground-water withdrawals. Development reduces simulated ground-water discharge to streams in the Upper Aquifer from 61.4 to 10% of the Upper Aquifer hydrologic budget (28.9%, if impounded stream flow is included). Ground-water discharge to streams in the Middle Aquifer decreases from 80.0 to 22% of the Middle Aquifer hydrologic budget. The utility of assessing ground-water/surface-water interaction in a regional hydrogeologic system by simulation responses to development is demonstrated and which can compensate for lack of long-term stream-gaging data in determining management decisions.
Pulsed high voltage electric discharge disinfection of microbially contaminated liquids.
Anpilov, A M; Barkhudarov, E M; Christofi, N; Kop'ev, V A; Kossyi, I A; Taktakishvili, M I; Zadiraka, Y
2002-01-01
To examine the use of a novel multielectrode slipping surface discharge (SSD) treatment system, capable of pulsed plasma discharge directly in water, in killing micro-organisms. Potable water containing Escherichia coli and somatic coliphages was treated with pulsed electric discharges generated by the SSD. The SSD system was highly efficient in the microbial disinfection of water with a low energy utilization (eta approximately 10-4 kW h l-1). The SSD treatment was effective in the destruction of E. coli and its coliphages through the generation of u.v. radiation, ozone and free radicals. The non-thermal treatment method can be used for the eradication of micro-organisms in a range of contaminated liquids, including milk, negating the use of pasteurization. The method utilizes multipoint electric discharges capable of treating large volumes of liquid under static and flowing regimes.
Mkanta, William N.; Chumbler, Neale R.; Yang, Kai; Saigal, Romesh; Abdollahi, Mohammad; Mejia de Grubb, Maria C.; Ezekekwu, Emmanuel U.
2017-01-01
Ability to predict discharge destination would be a useful way of optimizing posthospital care. We conducted a cross-sectional, multiple state study of inpatient services to assess the likelihood of home discharges in 2009 among Medicaid enrollees who were discharged following general hospitalizations. Analyses were conducted using hospitalization data from the states of California, Georgia, Michigan, and Mississippi. A total of 33 160 patients were included in the study among which 13 948 (42%) were discharged to their own homes and 19 212 (58%) were discharged to continue with institutional-based treatment. A multiple logistic regression model showed that gender, age, race, and having ambulatory care-sensitive conditions upon admission were significant predictors of home-based discharges. Females were at higher odds of home discharges in the sample (odds ratio [OR] = 1.631; 95% confidence interval [CI], 1.520-1.751), while patients with ambulatory care-sensitive conditions were less likely to get home discharges (OR = 0.739; 95% CI, 0.684-0.798). As the nation engages in the continued effort to improve the effectiveness of the health care system, cost savings are possible if providers and systems of care are able to identify admission factors with greater prospects for in-home services after discharge.
Experimental Investigation of A Heat Pipe-Assisted Latent Heat Thermal Energy Storage System
NASA Astrophysics Data System (ADS)
Tiari, Saeed; Mahdavi, Mahboobe; Qiu, Songgang
2016-11-01
In the present work, different operation modes of a latent heat thermal energy storage system assisted by a heat pipe network were studied experimentally. Rubitherm RT55 enclosed by a vertical cylindrical container was used as the Phase Change Material (PCM). The embedded heat pipe network consisting of a primary heat pipe and an array of four secondary heat pipes were employed to transfer heat to the PCM. The primary heat pipe transports heat from the heat source to the heat sink. The secondary heat pipes transfer the extra heat from the heat source to PCM during charging process or retrieve thermal energy from PCM during discharging process. The effects of heat transfer fluid (HTF) flow rate and temperature on the thermal performance of the system were investigated for both charging and discharging processes. It was found that the HTF flow rate has a significant effect on the total charging time of the system. Increasing the HTF flow rate results in a remarkable increase in the system input thermal power. The results also showed that the discharging process is hardly affected by the HTF flow rate but HTF temperature plays an important role in both charging and discharging processes. The authors would like to acknowledge the financial supports by Temple University for the project.
[Desulphurization with multi-needle-water film electrodes by corona discharge].
Huang, Xu-ran; Li, Guo-feng; Li, Jie; Wu, Yan
2008-09-01
The study of this paper adopted stainless steel multi-needle as a high voltage electrode system, and water film as low voltage electrode. The electrodes were supplied with negative DC high voltage. Polluted gas containing sulfur dioxide (SO2) flowed into the corona discharge field from the center of the high voltage electrode system in an axis direction, then get across the water surface. Under the effect of corona discharge plasma and water absorption, SO2 was removed by converting it into sulfuric acid. The effect of the three factors which were the applied voltage, SO2 inlet concentration and duration of the exposure to the corona discharge on desulphurization efficiency has been studied mostly. Moreover, the concentrations of SO3(2-) and SO4(2-) ions in the water were measured and the mechanism of desulphurization was analyzed. The results showed that there was a synergistic effect on the removal of SO2 when combining corona discharge and water absorption, and both the desulphurization efficiency and the amount of sulfuric acid increased evidently. As the applied voltage and the duration increased, the desulphurization efficiency increased. Also, the SO2 inlet concentration had effect on desulphurization efficiency. When the SO2 inlet concentration was 430 x 10(-6), the voltage was 14.5 kV and the duration was 7.5 s, a desulphurization efficiency of more than 90% could be attained.
Liu, J; Li, Y P; Huang, G H; Zeng, X T; Nie, S
2016-01-01
In this study, an interval-stochastic-based risk analysis (RSRA) method is developed for supporting river water quality management in a rural system under uncertainty (i.e., uncertainties exist in a number of system components as well as their interrelationships). The RSRA method is effective in risk management and policy analysis, particularly when the inputs (such as allowable pollutant discharge and pollutant discharge rate) are expressed as probability distributions and interval values. Moreover, decision-makers' attitudes towards system risk can be reflected using a restricted resource measure by controlling the variability of the recourse cost. The RSRA method is then applied to a real case of water quality management in the Heshui River Basin (a rural area of China), where chemical oxygen demand (COD), total nitrogen (TN), total phosphorus (TP), and soil loss are selected as major indicators to identify the water pollution control strategies. Results reveal that uncertainties and risk attitudes have significant effects on both pollutant discharge and system benefit. A high risk measure level can lead to a reduced system benefit; however, this reduction also corresponds to raised system reliability. Results also disclose that (a) agriculture is the dominant contributor to soil loss, TN, and TP loads, and abatement actions should be mainly carried out for paddy and dry farms; (b) livestock husbandry is the main COD discharger, and abatement measures should be mainly conducted for poultry farm; (c) fishery accounts for a high percentage of TN, TP, and COD discharges but a has low percentage of overall net benefit, and it may be beneficial to cease fishery activities in the basin. The findings can facilitate the local authority in identifying desired pollution control strategies with the tradeoff between socioeconomic development and environmental sustainability.
2011-03-24
and radiation resistance of rare earth permanent magnets for applications such as ion thrusters and high efficiency Stirling Radioisotope Generators...from Electron Transitioning Discharge Current Discharge Power Discharge Voltage Θ Divergence Angle Earths Gravity at Sea Level...Hall effect thruster HIVAC High Voltage Hall Accelerator LEO Low Earth Orbit LDS Laser Displacement System LVDT Linear variable differential
Power Balance Modeling of Local Helicity Injection for Non-Solenoidal ST Startup
NASA Astrophysics Data System (ADS)
Weberski, J. D.; Barr, J. L.; Bongard, M. W.; Fonck, R. J.; Perry, J. M.; Reusch, J. A.
2017-10-01
A zero-dimensional power balance model for predicting Ip(t) for Local Helicity Injection (LHI) discharges has been used to interpret experimental results from recent experimental campaigns using high-field-side (HFS) helicity injection. This model quantifies LHI's effective drive (Veff) through helicity balance while enforcing the Taylor relaxation current limit and tracking inductive effects to determine Ip(t) . Recent analysis of HFS LHI discharges indicate LHI is the dominant source of drive and provides Veff up to 1.3 V while geometric effects and inductive drive provide < 0.1 V throughout much of the discharge. In contrast to previous analysis of low-field-side (LFS) LHI discharges, which were driven by Veff = 0.3 V and 2.0 V from geometric effects and inductive drive. A significant remaining uncertainty in the model is the resistive dissipation of LHI discharges. This requires greater understanding of LHI confinement scaling and impurity content, which are currently under investigation. However, the model and experimental Ip(t) exhibit good agreement for parameters consistent with previous experimental findings. Extrapolation of plasma parameters and shaping from recent experiments allow for the model to project the performance of LHI systems. These projections indicate Ip 0.3 MA can be accessed on Pegasus via HFS LHI through changes to injector geometry to provide more Veff. This regime can be accessed via a LFS system by increasing the Taylor relaxation current limit early in the discharge. Work supported by US DOE Grants DE-FG02-96ER54375 and DE-SC0006928.
Liquid hydrogen turbopump rapid start program. [thermal preconditioning using coatings
NASA Technical Reports Server (NTRS)
Wong, G. S.
1973-01-01
This program was to analyze, test, and evaluate methods of achieving rapid-start of a liquid hydrogen feed system (inlet duct and turbopump) using a minimum of thermal preconditioning time and propellant. The program was divided into four tasks. Task 1 includes analytical studies of the testing conducted in the other three tasks. Task 2 describes the results from laboratory testing of coating samples and the successful adherence of a KX-635 coating to the internal surfaces of the feed system tested in Task 4. Task 3 presents results of testing an uncoated feed system. Tank pressure was varied to determine the effect of flowrate on preconditioning. The discharge volume and the discharge pressure which initiates opening of the discharge valve were varied to determine the effect on deadhead (no through-flow) start transients. Task 4 describes results of testing a similar, internally coated feed system and illustrates the savings in preconditioning time and propellant resulting from the coatings.
Effect of Propellant Feed System Coupling and Hydraulic Parameters on Analysis of Chugging
NASA Technical Reports Server (NTRS)
Wood, Don J.; Dorsch, Robert G.
1967-01-01
A digital distributed parameter model was used to study the effects of propellant-feed- system coupling and various hydraulic parameters on the analytical prediction of chugging instabilities. Coupling between the combustion chamber and feed system was controlled by varying the compliance of the injector-dome region. The coupling with the feed system above the pump was varied by changing the amount of cavitation compliance at the pump inlet. The stability limits and chugging frequencies proved to be strongly dependent on the degree of feed-system coupling. The maximum stability condition occurred with intermediate coupling. Under conditions of a high degree of feed-system-combustor coupling, the stability limits and chugging frequencies were primarily dependent on the feed-system characteristics; the responses were characterized by beating patterns. For the system analyzed, the pump suction line had little effect on the stability limits or chugging frequencies. Beating, present under the condition of near zero injector -dome compliance, was eliminated when the suction line was decoupled by employing a sufficiently high value of pump-inlet compliance. Under conditions of maximum feed-system coupling, the magnitude and distribution of line losses in the discharge line had a significant effect on the stability limits but had negligible effect on the chugging frequency and beating characteristics. Also, the length of the discharge line greatly affected the stability limits, chugging frequency, and beating characteristics. The length of the suction line, however, had little effect on the stability limits and chugging frequency but did influence the beating pattern. A resistive-shunt device attached to the pump discharge line to suppress chugging was investigated. The analysis showed that the device was effective under conditions of high feed-system coupling.
Treatment of Wastewater with High Conductivity by Pulsed Discharge Plasma
NASA Astrophysics Data System (ADS)
Wang, Zhaojun; Jiang, Song; Liu, Kefu
2014-07-01
A wastewater treatment system was established by means of pulsed dielectric barrier discharge (DBD). The main advantage of this system is that the wastewater is employed as one of the electrodes for the degradation of rhodamine B, which makes use of the high conductivity and lessenes its negative influence on the discharge process. At the same time, the reactive species like ozone and ultraviolet (UV) light generated by the DBD can be utilized for the treatment of wastewater. The effects of some factors like conductivity, peak pulse voltage, discharge frequency and pH values were investigated. The results show that the combination of these reactive species could enhance the degradation of the dye while the ozone played the most important role in the process. The degradation efficiency was enhanced with the increase of energy supplied. The reduction in the concentration of rhodamine B was much more effective with high solution conductivity; under the highest conductivity condition, the degradation rate could rise to 99%.
Simulation of diffuse-charge capacitance in electric double layer capacitors
NASA Astrophysics Data System (ADS)
Sun, Ning; Gersappe, Dilip
2017-01-01
We use a Lattice Boltzmann Model (LBM) in order to simulate diffuse-charge dynamics in Electric Double Layer Capacitors (EDLCs). Simulations are carried out for both the charge and the discharge processes on 2D systems of complex random electrode geometries (pure random, random spheres and random fibers). The steric effect of concentrated solutions is considered by using a Modified Poisson-Nernst-Planck (MPNP) equations and compared with regular Poisson-Nernst-Planck (PNP) systems. The effects of electrode microstructures (electrode density, electrode filler morphology, filler size, etc.) on the net charge distribution and charge/discharge time are studied in detail. The influence of applied potential during discharging process is also discussed. Our studies show how electrode morphology can be used to tailor the properties of supercapacitors.
NASA Astrophysics Data System (ADS)
Felder, Guido; Zischg, Andreas; Weingartner, Rolf
2015-04-01
Estimating peak discharges with very low probabilities is still accompanied by large uncertainties. Common estimation methods are usually based on extreme value statistics applied to observed time series or to hydrological model outputs. However, such methods assume the system to be stationary and do not specifically consider non-stationary effects. Observed time series may exclude events where peak discharge is damped by retention effects, as this process does not occur until specific thresholds, possibly beyond those of the highest measured event, are exceeded. Hydrological models can be complemented and parameterized with non-linear functions. However, in such cases calibration depends on observed data and non-stationary behaviour is not deterministically calculated. Our study discusses the option of considering retention effects on extreme peak discharges by coupling hydrological and hydraulic models. This possibility is tested by forcing the semi-distributed deterministic hydrological model PREVAH with randomly generated, physically plausible extreme precipitation patterns. The resulting hydrographs are then used to force the hydraulic model BASEMENT-ETH (riverbed in 1D, potential inundation areas in 2D). The procedure ensures that the estimated extreme peak discharge does not exceed the physical limit given by the riverbed capacity and that the dampening effect of inundation processes on peak discharge is considered.
Water quality trading (WQT) under the Clean Water Act is a compliance option for water quality based effluent limitations in a National Pollutant Discharge Elimination System (NPDES) permit (i.e., the requirements for discharging, monitoring, and reporting). States that have enac...
Condenser for extreme-UV lithography with discharge source
Sweatt, William C.; Kubiak, Glenn D.
2001-01-01
Condenser system, for use with a ringfield camera in projection lithography, employs quasi grazing-incidence collector mirrors that are coated with a suitable reflective metal such as ruthenium to collect radiation from a discharge source to minimize the effect of contaminant accumulation on the collecting mirrors.
NASA Astrophysics Data System (ADS)
Shang, Kefeng; Wang, Hao; Li, Jie; Lu, Na; Jiang, Nan; Wu, Yan
2017-06-01
Pulsed discharge in water and over water surfaces generates ultraviolet radiation, local high temperature, shock waves, and chemical reactive species, including hydroxyl radicals, hydrogen peroxide, and ozone. Pulsed discharge plasma (PDP) can oxidize and mineralize pollutants very efficiently, but high energy consumption restricts its application for industrial wastewater treatment. A novel method for improving the energy efficiency of wastewater treatment by PDP was proposed, in which peroxydisulfate (PDS) was added to wastewater and PDS was activated by PDP to produce more strong oxidizing radicals, including sulfate radicals and hydroxyl radicals, leading to a higher oxidation capacity for the PDP system. The experimental results show that the increase in solution conductivity slightly decreased the discharge power of the pulse discharge over the water surface. An increase in the discharge intensity improved the activation of PDS and therefore the degradation efficiency and energy efficiency of p-nitrophenol (PNP). An increase in the addition dosage of PDS greatly facilitated the degradation of PNP at a molar ratio of PDS to PNP of lower than 80:1, but the performance enhancement was no longer obvious at a dosage of more than 80:1. Under an applied voltage of 20 kV and a gas discharge gap of 2 mm, the degradation efficiency and energy efficiency of the PNP reached 90.7% and 45.0 mg kWh-1 for the plasma/PDS system, respectively, which was 34% and 18.0 mg kWh-1 higher than for the discharge plasma treatment alone. Analysis of the physical and chemical effects indicated that ozone and hydrogen peroxide were important for PNP degradation and UV irradiation and heat from the discharge plasma might be the main physical effects for the activation of PDS.
Effect of residence times on River Mondego estuary eutrophication vulnerability.
Duarte, A S; Pinho, J L; Pardal, M A; Neto, J M; Vieira, J P; Santos, F S
2001-01-01
The south arm of the Mondego estuary, located in the central western Atlantic coast of Portugal, is almost silted up in the upstream area. So, the water circulation is mostly driven by tides and the tributary river Pranto discharges. Eutrophication has been taking place in this ecosystem during last twelve years, where macroalgae reach a luxuriant development covering a significant area of the intertidal muddy flat. A sampling program was carried out from June 1993 to June 1994. Available data on salinity profiles and on nutrients loading into the south arm were used in order to get a better understanding of the ongoing changes. River Pranto flow discharges, controlled by a sluice, were also monitored. Integral formulations are typically based on assumptions of steady state and well-mixed systems and thus cannot take into account the space and time variability of estuarine residence times, due to river discharge flow, tidal coefficients, discharge(s) location and time of release during the tidal cycle. This work presents the hydrodynamics modelling (2D-H) of this system in order to estimate the residence times variability and to assess their effect on the estuarine eutrophication vulnerability, contributing to better environmental management strategies selection.
Design Flexibility of Redox Flow Systems. [for energy storage applications
NASA Technical Reports Server (NTRS)
Hagedorn, N. H.; Thaller, L. H.
1982-01-01
The characteristics inherent in Redox flow systems permit considerable latitude in designing systems for specific storage applications. The first of these characteristics is the absence of plating/deplating reactions with their attendant morphology changes at the electrodes. This permits a given Redox system to operate over a wide range of depths of discharge and charge/discharge rates. The second characteristic is the separation of power generating components (stacks) from the energy storage components (tanks). This results in cost effective system design, ease of system growth via modularization, and freedom from sizing restraints so that the whole spectrum of applications, from utilities down to single residence can be considered. The final characteristic is the commonality of the reactant fluids which assures that all cells at all times are receiving reactants at the same state of charge. Since no cell can be out of balance with respect to any other cell, it is possible for some cells to be charged while others are discharging, in effect creating a DC to DC transformer. It is also possible for various groups of cells to be connected to separate loads, thus supplying a range of output voltages. Also, trim cells can be used to maintain constant bus voltage as the load is changed or as the depth of discharge increases. The commonality of reactant fluids also permits any corrective measures such as rebalancing to occur at the system level instead of at the single cell level.
Gotlib Conn, Lesley; Zwaiman, Ashley; DasGupta, Tracey; Hales, Brigette; Watamaniuk, Aaron; Nathens, Avery B
2018-01-01
Challenges delivering quality care are especially salient during hospital discharge and care transitions. Severely injured patients discharged from a trauma centre will go either home, to rehabilitation or another acute care hospital with complex management needs. This purpose of this study was to explore the experiences of trauma patients and families treated in a regional academic trauma centre to better understand and improve their discharge and care transition experiences. A qualitative study using inductive thematic analysis was conducted between March and October 2016. Telephone interviews were conducted with trauma patients and/or a family member after discharge from the trauma centre. Data collection and analysis were completed inductively and iteratively consistent with a qualitative approach. Twenty-four interviews included 19 patients and 7 family members. Participants' experiences drew attention to discharge and transfer processes that either (1) Fostered quality discharge or (2) Impeded quality discharge. Fostering quality discharge was ward staff preparation efforts; establishing effective care continuity; and, adequate emotional support. Impeding discharge quality was perceived pressure to leave the hospital; imposed transfer decisions; and, sub-optimal communication and coordination around discharge. Patient-provider communication was viewed to be driven by system, rather than patient need. Inter-facility information gaps raised concern about receiving facilities' ability to care for injured patients. The quality of trauma patient discharge and transition experiences is undermined by system- and ward-level processes that compete, rather than align, in producing high quality patient-centred discharge. Local improvement solutions focused on modifiable factors within the trauma centre include patient-oriented discharge education and patient navigation; however, these approaches alone may be insufficient to enhance patient experiences. Trauma patients encounter complex barriers to quality discharge that likely require a comprehensive, multimodal intervention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Payment source and length of use among home health agency discharges.
Han, Beth; Remsburg, Robin E; Lubitz, James; Goulding, Margie
2004-11-01
Our study compared (1) length of use among home health care (HHC) discharges with Medicare, Medicaid, or private health insurance between 1991 and 2000 and (2) factors associated with length of HHC use among discharges with Medicare, Medicaid, or private health insurance. Data were obtained from the 1992, 1994, 1996, 1998, and 2000 National Home and Hospice Care Surveys (n = 18,416). Logistic regressions and stratified analyses by primary payment source were applied. After adjusting for covariates, Medicare HHC patients were from 0.52 to 0.75 times less likely to be discharged within 30 days in 1991-1996 than in 1997-1998. Medicaid patients were 0.37 times less likely to be discharged within 30 days in 1991-1992 than in 1997-1998. Patients with private insurance were 2.05 times more likely to be discharged within 30 days in 1993-1994 than in 1997-1998. No significant difference in length of use was found at the multivariate level between 1997-1998 and 1999-2000 among HHC patients with Medicare, Medicaid, or private health insurance. Results for being discharged within 60 days were similar to these described above. Our study shows that length of HHC use among Medicare discharges decreased after the implementation of the Medicare interim payment system. We did not find a spillover effect of the Medicare interim payment system on length of HHC use among discharges with Medicaid or private health insurance. Our results can help health professionals and policy makers better understand the dynamic associations between payment systems and length of use of HHC services.
Characterization of electrical discharges on Teflon dielectrics used as spacecraft thermal control
NASA Technical Reports Server (NTRS)
Yadlowsky, E. J.; Hazelton, R. C.; Churchill, R. J.
1979-01-01
The dual effects of system degradation and reduced life of synchronous-orbit satellites as a result of differential spacecraft charging underscore the need for a clearer understanding of the prevailing electrical discharge phenomena. In a laboratory simulation, the electrical discharge current, surface voltage, emitted particle fluxes, and photo-emission associated with discharge events on electron beam irradiated silver-backed Teflon samples were measured. Sample surface damage was examined with optical and electron beam microscopes. The results are suggestive of a model in which the entire sample surface is discharged by lateral sub-surface currents flowing from a charge deposition layer through a localized discharge channel to the back surface of the sample. The associated return current pulse appears to have a duration which may be a signature by which different discharge processes may be characterized.
Discharge destination following hip fracture: comparative effectiveness and cost analyses.
Pitzul, Kristen B; Wodchis, Walter P; Kreder, Hans J; Carter, Michael W; Jaglal, Susan B
2017-09-30
This study determines outcomes and costs of similar hip fracture patients that were discharged from hospital to a rehabilitation facility or to the community within 1 year. Community patients had worse outcomes and lower costs compared to rehabilitation facility patients. This study contributes to understanding hip fracture quality of care. The purpose of this study is to determine the impact on mortality and rehospitalization, as well as health system cost, of similar hip fracture patients being discharged to an inpatient rehabilitation facility or directly to the community within 1 year in Ontario, Canada. This was a retrospective study of a propensity-matched cohort completed from the health system perspective. Administrative databases were used to identify and match two groups of older adults (total n = 18,773) discharged alive from acute care for hip fracture repair: patients discharged to inpatient rehabilitation were matched to patients discharged to the community. A higher proportion of patients discharged to the community (27-42%) died or were rehospitalized (SD highipr = 0.21, SD lowipr = 0.33) and had substantially lower health system costs (SD highipr = 0.65, SD lowipr = 0.42) up to 1 year post-acute discharge compared to similar patients discharged to inpatient rehabilitation facilities (IPR) (10-11%). This study demonstrates that similar hip fracture patients are discharged to different post-acute settings (i.e., home-based rehabilitation and inpatient rehabilitation) and have different outcomes, thereby calling into question the appropriateness of post-acute rehabilitation delivery in Ontario, Canada. Future research should focus on determining how trade-offs in resource allocation between settings would impact patient outcomes.
Discharge characteristics of four highway drainage systems in Ohio
Straub, D.E.
1995-01-01
Excessive water in the subbase of high-way combined with large traffic volumes and heavy loads is a major cause of road deterioration. Prompt removal of any excess water in a subbase will decrease the road deterioration and extend the effective life of a highway. This study presents discharge characteristics of four highway subbase drainage systems. These systems consisted of shallow, longitudal trenches with geocomposite drain materials (edge drains made from a polyethylene core surrounded by a geotextile filter fabric) that underline the joint between the shoulder and the traffic lane of State Route 16, approximately 1.0 mile southeast of Granville, Ohio. For selected rainfall-runoff events the maximum discharge, discharge characteristics from April 1991 through November 1993 were computed for three geocomposite products- a post type, an oblong-pipe type, and a cusp type-and a conventional perforated pipe edge drain. In general, the discharge characteristics of the conventional edge drain and that of the oblong-pipe edge drain were similar for most of the rainfall-runoff event characteristics. Both produced most of the highest maximum discharges and largest discharge volumes among the four longitudal edge drains. The post edge drain produced smaller maximum discharge and volumes than the conventional and oblong-pipe edge drains, but it had the shortest lag times for most of the event characteristics. The cusp edge drain produced small maximum discharges and small volumes similar to those from the post edge drain, but it had the longest lag times of all the edge drains for most of the event characteristics. The cusp edge drain may have also had some problems during installation which could have affected the discharge characteristics.
System and method for altering characteristics of materials using an electrohydraulic discharge
Banerjee, Sujit
2003-06-03
System and method for oxidizing contaminants to alter specific properties, such as tack, of contaminants. The present invention reduces the tack of the stickies and pitch by exposing the materials for a short duration to low-energy pulsed electrical discharges between a pair of electrodes that are submerged in a liquid medium, such as a fiber stream, water, a pulp slurry, or whitewater. An electrical discharge in the liquid medium oxidizes materials, which may be dissolved or suspended therein, such as stickies, pitch, sulfide, ink, toner, and other substances, thereby reducing tack, odor, and/or zeta potential, as well as producing other desirable effect.
Advanced high frequency partial discharge measuring system
NASA Technical Reports Server (NTRS)
Karady, George G.
1994-01-01
This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.
Effects of Prospective Payment Financing on Rehabilitation Income.
ERIC Educational Resources Information Center
Evans, Ron L.; And Others
1990-01-01
This study compared 187 patients discharged from a Veterans Administration hospital rehabilitation unit with 215 discharges that occurred following implementation of a prospective payment system. There were no significant differences in demographics, self-care ability, or readmissions. Length of stay and referrals for home health care decreased,…
Wilcox, Christie L.; Headlam, Jasmine L.; Doyle, Thomas K.; Yanagihara, Angel A.
2017-01-01
Stings from the hydrozoan species in the genus Physalia cause intense, immediate skin pain and elicit serious systemic effects. There has been much scientific debate about the most appropriate first aid for these stings, particularly with regard to whether vinegar use is appropriate (most current recommendations recommend against vinegar). We found that only a small percentage (≤1.0%) of tentacle cnidae discharge during a sting event using an ex vivo tissue model which elicits spontaneous stinging from live cnidarian tentacles. We then tested a variety of rinse solutions on both Atlantic and Pacific Physalia species to determine if they elicit cnidae discharge, further investigating any that did not cause immediate significant discharge to determine if they are able to inhibit cnidae discharge in response to chemical and physical stimuli. We found commercially available vinegars, as well as the recently developed Sting No More® Spray, were the most effective rinse solutions, as they irreversibly inhibited cnidae discharge. However, even slight dilution of vinegar reduced its protective effects. Alcohols and folk remedies, such as urine, baking soda and shaving cream, caused varying amounts of immediate cnidae discharge and failed to inhibit further discharge, and thus likely worsen stings. PMID:28445412
NASA Astrophysics Data System (ADS)
Tang, Enling; Zhao, Liangliang; Han, Yafei; Zhang, Qingming; Wang, Ruizhi; He, Liping; Liu, Shuhua
2018-04-01
Due to the actual situation of spacecraft surface' charging, such as convex corners, weld line, whalebone and a multiple-interfaces with different materials, all these are main factors leading to uneven charging of spacecraft surface, even creating gradient potential. If the charging spacecraft surface is impacted by debris or micrometeor, discharge effect induced by impacting will pose a serious threat to spacecraft in orbit. So realizing spacecraft charging surface with different potential differences and grasping discharge characteristics are a decisive importance at the different experimental conditions in laboratory. To simulate the spacecraft surface with a gradient potential in laboratory, spacecraft surface is split into different parts, which different gaps reserved in 2 adjacent surface is added resistance to create different potential surfaces, and the high potential surface as a impact target in the split targets. Charging circuit system realizing different gradient potential and discharge test system are built by ourselves, combining with two-stage light gas gun loading system, six sets of experiments have been performed about hypervelocity impact on 2A12 aluminum split targets with gradient potentials. In the experiments, gaps of 2A12 aluminum target are the same among different parts in every experiments, the gaps of the split targets are 2mm, 3mm, 5mm, 7mm and 10mm in the experiments, respectively. And the applied voltage is 300V in all the experiments and high-potential 2A12 aluminum plate as the impact target. The experiments have been performed at the impact velocity of about 3km/s and the incidence angles of 60o and 90o (between projectile flying trajectory and target plane), respectively. Voltage probe and current probes are used for acquiring discharge voltages and currents during the process of the impact. The experimental results showed that the discharge induced by impact plasma were generated among high and low-potential target by forming a plasma discharge channel. With the increasing of the gaps among the high and low-potential targets, the peak values of the discharge current decreased first then increased. When the gaps of split targets reached a certain value, the peak values of the discharge current decreased again. Meanwhile, the gaps among high and low-potential targets was 5mm, the peak value of the discharge current was the smallest. With the increasing of the gaps among the split targets, a primary discharge duration also increased. However, when the gaps among the split targets were greater than 5mm, increasing trend of discharge duration would slow down. When the gaps among the split targets were greater than 7mm, there was a secondary discharge phenomenon, and the physical explanations were given about the influence of different gaps among the split targets on the discharge effects created by hypervelocity impact.
Performance Charts for a Turbojet System
NASA Technical Reports Server (NTRS)
Karp, Irving M.
1947-01-01
Convenient charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet system. These charts take into account the effects of ram pressure, compressor pressure ratio, ratio of combustion-chamber-outlet temperature to atmospheric temperature, compressor efficiency, turbine efficiency, combustion efficiency, discharge-nozzle coefficient, losses in total pressure in the inlet to the jet-propulsion unit and in the combustion chamber, and variation in specific heats with temperature. The principal performance charts show clearly the effects of the primary variables and correction charts provide the effects of the secondary variables. The performance of illustrative cases of turbojet systems is given. It is shown that maximum thrust per unit mass rate of air flow occurs at a lower compressor pressure ratio than minimum specific fuel consumption. The thrust per unit mass rate of air flow increases as the combustion-chamber discharge temperature increases. For minimum specific fuel consumption, however, an optimum combustion-chamber discharge temperature exists, which in some cases may be less than the limiting temperature imposed by the strength temperature characteristics of present materials.
Perri-Moore, Seneca; Kuang, Jinqiu; Bray, Bruce E; Ngo, Long; Doig, Alexa; Zeng-Treitler, Qing
2016-01-01
Objectives First, to evaluate the effect of standard vs pictograph-enhanced discharge instructions on patients’ immediate and delayed recall of and satisfaction with their discharge instructions. Second, to evaluate the effect of automated pictograph enhancement on patient satisfaction with their discharge instructions. Materials and Methods Glyph, an automated healthcare informatics system, was used to automatically enhance patient discharge instructions with pictographs. Glyph was developed at the University of Utah by our research team. Patients in a cardiovascular medical unit were randomized to receive pictograph-enhanced or standard discharge instructions. Measures of immediate and delayed recall and satisfaction with discharge instructions were compared between two randomized groups: pictograph (n = 71) and standard (n = 73). Results Study participants who received pictograph-enhanced discharge instructions recalled 35% more of their instructions at discharge than those who received standard discharge instructions. The ratio of instructions at discharge was: standard = 0.04 ± 0.03 and pictograph-enhanced = 0.06 ± 0.03. The ratio of instructions at 1 week post discharge was: standard = 0.04 ± 0.02 and pictograph-enhanced 0.04 ± 0.02. Additionally, study participants who received pictograph-enhanced discharge instructions were more satisfied with the understandability of their instructions at 1 week post-discharge than those who received standard discharge instructions. Discussion Pictograph-enhanced discharge instructions have the potential to increase patient understanding of and satisfaction with discharge instructions. Conclusion It is feasible to automatically illustrate discharge instructions and provide them to patients in a timely manner without interfering with clinical work. Illustrations in discharge instructions were found to improve patients’ short-term recall of discharge instructions and delayed satisfaction (1-week post hospitalization) with the instructions. Therefore, it is likely that patients’ understanding of and interaction with their discharge instructions is improved by the addition of illustrations. PMID:27234601
Hill, Brent; Perri-Moore, Seneca; Kuang, Jinqiu; Bray, Bruce E; Ngo, Long; Doig, Alexa; Zeng-Treitler, Qing
2016-11-01
First, to evaluate the effect of standard vs pictograph-enhanced discharge instructions on patients' immediate and delayed recall of and satisfaction with their discharge instructions. Second, to evaluate the effect of automated pictograph enhancement on patient satisfaction with their discharge instructions. Glyph, an automated healthcare informatics system, was used to automatically enhance patient discharge instructions with pictographs. Glyph was developed at the University of Utah by our research team. Patients in a cardiovascular medical unit were randomized to receive pictograph-enhanced or standard discharge instructions. Measures of immediate and delayed recall and satisfaction with discharge instructions were compared between two randomized groups: pictograph (n = 71) and standard (n = 73). Study participants who received pictograph-enhanced discharge instructions recalled 35% more of their instructions at discharge than those who received standard discharge instructions. The ratio of instructions at discharge was: standard = 0.04 ± 0.03 and pictograph-enhanced = 0.06 ± 0.03. The ratio of instructions at 1 week post discharge was: standard = 0.04 ± 0.02 and pictograph-enhanced 0.04 ± 0.02. Additionally, study participants who received pictograph-enhanced discharge instructions were more satisfied with the understandability of their instructions at 1 week post-discharge than those who received standard discharge instructions. Pictograph-enhanced discharge instructions have the potential to increase patient understanding of and satisfaction with discharge instructions. It is feasible to automatically illustrate discharge instructions and provide them to patients in a timely manner without interfering with clinical work. Illustrations in discharge instructions were found to improve patients' short-term recall of discharge instructions and delayed satisfaction (1-week post hospitalization) with the instructions. Therefore, it is likely that patients' understanding of and interaction with their discharge instructions is improved by the addition of illustrations. Published by Oxford University Press on behalf of the American Medical Informatics Association 2015. This work is written by US Government employees and is in the public domain in the United States.
Frehmann, T; Nafo, I; Niemann, A; Geiger, W F
2002-01-01
For the examination of the effects of different storm water management strategies in an urban catchment area on receiving water quality, an integrated simulation of the sewer system, wastewater treatment plant and receiving water is carried out. In the sewer system real-time control measures are implemented. As examples of source control measures the reduction of wastewater and the reduction of the amount of impervious surfaces producing storm water discharges are examined. The surface runoff calculation and the simulation of the sewer system and the WWTP are based on a MATLAB/SIMULINK simulation environment. The impact of the measures on the receiving water is simulated using AQUASIM. It can be shown that the examined storm water management measures, especially the source control measures, can reduce the combined sewer overflow volume and the pollutant discharge load considerably. All examined measures also have positive effects on the receiving water quality. Moreover, the reduction of impervious surfaces avoids combined sewer overflow activities, and in consequence prevents pollutants from discharging into the receiving water after small rainfall events. However, the receiving water quality improvement may not be seen as important enough to avoid acute receiving water effects in general.
Optimization of a Small-Scale Engine Using Plasma Enhanced Ignition
2013-03-01
PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 6. AUTHOR(S) 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT...systems were tested in the small engine and their effects on engine performance determined through comparison with a regular spark discharge (thermal...pulse plasma discharge system purchased from Plasmatronics LLC. Air fuel ratio (λ units are used in this report) sweeps were performed at several
Radionuclides in groundwater flow system understanding
NASA Astrophysics Data System (ADS)
Erőss, Anita; Csondor, Katalin; Horváth, Ákos; Mádl-Szőnyi, Judit; Surbeck, Heinz
2017-04-01
Using radionuclides is a novel approach to characterize fluids of groundwater flow systems and understand their mixing. Particularly, in regional discharge areas, where different order flow systems convey waters with different temperature, composition and redox-state to the discharge zone. Radium and uranium are redox-sensitive parameters, which causes fractionation along groundwater flow paths. Discharging waters of regional flow systems are characterized by elevated total dissolved solid content (TDS), temperature and by reducing conditions, and therefore with negligible uranium content, whereas local flow systems have lower TDS and temperature and represent oxidizing environments, and therefore their radium content is low. Due to the short transit time, radon may appear in local systems' discharge, where its source is the soil zone. However, our studies revealed the importance of FeOOH precipitates as local radon sources throughout the adsorption of radium transported by the thermal waters of regional flow systems. These precipitates can form either by direct oxidizing of thermal waters at discharge, or by mixing of waters with different redox state. Therefore elevated radon content often occurs in regional discharge areas as well. This study compares the results of geochemical studies in three thermal karst areas in Hungary, focusing on radionuclides as natural tracers. In the Buda Thermal Karst, the waters of the distinct discharge areas are characterized by different temperature and chemical composition. In the central discharge area both lukewarm (20-35°C, 770-980 mg/l TDS) and thermal waters (40-65°C, 800-1350 mg/l TDS), in the South only thermal water discharge (33-43°C, 1450-1700 mg/l TDS) occur. Radionuclides helped to identify mixing of fluids and to infer the temperature and chemical composition of the end members for the central discharge area. For the southern discharge zone mixing components could not be identified, which suggests different cave formation. The Bükk karst area is largely compartmentalized owing to the complex geological and structural build-up. Majority of the waters is low mineralized (TDS < 600 mg/l) regardless of their temperatures (8-77 °C). This may indicate deep but relatively fast/short flow paths. Thermal wells, characterized by higher TDS (1000-2500 mg/l) and radium content (400-1900 mBq/l), show the effects of hydrocarbon reservoir fluids. In the Villány Thermal Karst area the majority of the springs have lukewarm (20-26°C) waters with 712-930 mg/l TDS. Natural thermal water discharge (52-62°C, 1100 mg/l TDS) can be found only in Harkány. Here the highest concentration of radionuclides (226Ra: 230 mBq/l, 238+234U: 66 mBq/l, 222Rn: 43 Bq/l) suggest mixing of different flow systems. The results reflect the effect of different hydrogeological environments and flow regimes but similarities also could be revealed. The National Research, Development and Innovation Fund has provided financial support to the Villány project under the grant agreement no. PD 116227. The Bükk research was supported by the European Union and the State of Hungary, co-financed by the European Social Fund in the framework of TÁMOP-4.2.4.A/ 2-11/1-2012-0001 National Excellence Program. The Buda Thermal Karst research was funded by Shell International E&P and by the Hungarian Scientific Research Fund under the grant agreement no. NK 101356.
NASA Astrophysics Data System (ADS)
Santoro, N.; Mount, G.
2017-12-01
Acid mine drainage (AMD) emanating from three abandoned mines feed an estimated 126 pounds of iron per day into the Tanoma remediation wetlands located in Tanoma, Pennsylvania. Along with the iron released into the system, 1500-2800 gallons of AMD per minute is seasonally discharged into the passive system. This high rate of discharge produces areas of high velocity flow that scour the wetland bottom moving precipitants and destroying vegetation roots. Although the discharge into Tanoma is known to be damaging, other discharges to surface waters have shown iron and heavy metal concentrations several times higher, and are left untreated to enter reservoir systems. This draws attention to these remediation sites, the processes used to treat them, and the effectiveness of each site. With most of the research that's been conducted in the AMD remediation field relating to in-lab experiments on iron concentrations, there is very little information in the literature about the effects of these large influxes of heavy metals and the effects it has on the biodiversity and methane production within a AMD remediation site. This research investigates the presence and concentration of heavy metals with the treatment wetland and other surface water sources using inductively coupled plasma optical emission spectroscopy (ICP-OES) and drone based aerial photography. Furthermore, our ICP data is compared with biodiversity patterns and methane levels within the Tanoma AMD site to identify relationships and the potential effect they have on the productivity and effectiveness of the remediation site through time.
Computational study of arc discharges: Spark plug and railplug ignitors
NASA Astrophysics Data System (ADS)
Ekici, Ozgur
A theoretical study of electrical arc discharges that focuses on the discharge processes in spark plug and railplug ignitors is presented. The aim of the study is to gain a better understanding of the dynamics of electrical discharges, more specifically the transfer of electrical energy into the gas and the effect of this energy transfer on the flow physics. Different levels of computational models are presented to investigate the types of arc discharges seen in spark plugs and railplugs (i.e., stationary and moving arc discharges). Better understanding of discharge physics is important for a number of applications. For example, improved fuel economy under the constraint of stricter emissions standards and improved plug durability are important objectives of current internal combustion engine designs. These goals can be achieved by improving the existing systems (spark plug) and introducing more sophisticated ignition systems (railplug). In spite of the fact spark plug and railplug ignitors are the focus of this work, the methods presented in this work can be extended to study the discharges found in other applications such as plasma torches, laser sparks, and circuit breakers. The system of equations describing the physical processes in an air plasma is solved using computational fluid dynamics codes to simulate thermal and flow fields. The evolution of the shock front, temperature, pressure, density, and flow of a plasma kernel were investigated for both stationary and moving arcs. Arc propagation between the electrodes under the effects of gas dynamics and electromagnetic processes was studied for moving arcs. The air plasma is regarded as a continuum, single substance material in local thermal equilibrium. Thermophysical properties of high temperature air are used to take into consideration the important processes such as dissociation and ionization. The different mechanisms and the relative importance of several assumptions in gas discharges and thermal plasma modeling were investigated. Considering the complex nature of the studied problem, the computational models aid in analyzing the analytical theory and serve as relatively inexpensive tools when compared to experiments in design process.
Effective communication with primary care providers.
Smith, Karen
2014-08-01
Effective communication requires direct interaction between the hospitalist and the primary care provider using a standardized method of information exchange with the opportunity to ask questions and assign accountability for follow-up roles. The discharge summary is part of the process but does not provide the important aspects of handoff, such as closed loop communication and role assignments. Hospital discharge is a significant safety risk for patients, with more than half of discharged patients experiencing at least one error. Hospitalist and primary care providers need to collaborate to develop a standardized system to communicate about shared patients that meets handoff requirements. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bosilovich, Michael G.; Yang, Runhua; Houser, Paul R.
1998-01-01
Land surface hydrology for the Off-line Land-surface GEOS Analysis (OLGA) system and Goddard Earth Observing System (GEOS-1) Data Assimilation System (DAS) has been examined using a river routing model. The GEOS-1 DAS land-surface parameterization is very simple, using an energy balance prediction of surface temperature and prescribed soil water. OLGA uses near-surface atmospheric data from the GEOS-1 DAS to drive a more comprehensive parameterization of the land-surface physics. The two global systems are evaluated using a global river routing model. The river routing model uses climatologic surface runoff from each system to simulate the river discharge from global river basins, which can be compared to climatologic river discharge. Due to the soil hydrology, the OLGA system shows a general improvement in the simulation of river discharge compared to the GEOS-1 DAS. Snowmelt processes included in OLGA also have a positive effect on the annual cycle of river discharge and source runoff. Preliminary tests of a coupled land-atmosphere model indicate improvements to the hydrologic cycle compared to the uncoupled system. The river routing model has provided a useful tool in the evaluation of the GCM hydrologic cycle, and has helped quantify the influence of the more advanced land surface model.
Oil flow at the scroll compressor discharge: visualization and CFD simulation
NASA Astrophysics Data System (ADS)
Xu, Jiu; Hrnjak, Pega
2017-08-01
Oil is important to the compressor but has other side effect on the refrigeration system performance. Discharge valves located in the compressor plenum are the gateway for the oil when leaving the compressor and circulate in the system. The space in between: the compressor discharge plenum has the potential to separate the oil mist and reduce the oil circulation ratio (OCR) in the system. In order to provide information for building incorporated separation feature for the oil flow near the compressor discharge, video processing method is used to quantify the oil droplets movement and distribution. Also, CFD discrete phase model gives the numerical approach to study the oil flow inside compressor plenum. Oil droplet size distributions are given by visualization and simulation and the results show a good agreement. The mass balance and spatial distribution are also discussed and compared with experimental results. The verification shows that discrete phase model has the potential to simulate the oil droplet flow inside the compressor.
ERIC Educational Resources Information Center
Shouse, M. N.; Scordato, J. C.; Farber, P. R.
2004-01-01
Neural generators related to different sleep components have different effects on seizure discharge. These sleep-related systems can provoke seizure discharge propagation during nonrapid eye movement (NREM) sleep and can suppress propagation during REM sleep. Experimental manipulations of discrete physiological components were conducted in feline…
Collisionless electron heating in inductively coupled discharges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaing, K.C.; Aydemir, A.Y.
1996-07-01
A kinetic theory of collisionless electron heating is developed for inductively coupled discharges with a finite height L. The novel effect associated with the finite-length system is the resonance between the bounce motion of the electrons and the wave frequency, leading to enhanced heating. The theory is in agreement with results of particle simulations.
NASA Astrophysics Data System (ADS)
Hosseini, Seiyed Mossa; Ataie-Ashtiani, Behzad; Simmons, Craig T.
2017-09-01
A simple conceptual rainfall-runoff model is proposed for the estimation of groundwater balance components in complex karst aquifers. In the proposed model the effects of memory length of different karst flow systems of base-flow, intermediate-flow, and quick-flow and also time variation of recharge area (RA) during a hydrological year were investigated. The model consists of three sub-models: soil moisture balance (SMB), epikarst balance (EPB), and groundwater balance (GWB) to simulate the daily spring discharge. The SMB and EPB sub-models utilize the mass conservation equation to compute the variation of moisture storages in the soil cover and epikarst, respectively. The GWB sub-model computes the spring discharge hydrograph through three parallel linear reservoirs for base-flow, intermediate-flow, and quick-flow. Three antecedent recharge indices are defined and embedded in the model structure to deal with the memory effect of three karst flow systems to antecedent recharge flow. The Sasan Karst aquifer located in the semi-arid region of south-west Iran with a continuous long-term (21-years) daily meteorological and discharge data are considered to describe model calibration and validation procedures. The effects of temporal variations of RA of karst formations during the hydrological year namely invariant RA, two RA (winter and summer), four RA (seasonal), and twelve RA (monthly) are assessed to determine their impact on the model efficiency. Results indicated that the proposed model with monthly-variant RA is able to reproduce acceptable simulation results based on modified Kling-Gupta efficiency (KGE = -0.83). The results of density-based global sensitivity analysis for dry (June to September) and a wet (October to May) period reveal the dominant influence of RA (with sensitivity indices equal to 0.89 and 0.93, respectively) in spring discharge simulation. The sensitivity of simulated spring discharge to memory effect of different karst formations during the dry period is greater than the wet period. In addition, the results reveal the important role of intermediate-flow system in the hydrological modeling of karst systems during the wet period. Precise estimation of groundwater budgets for a better decision making regarding water supplies from complex karst systems with long memory effect can considerably be improved by use of the proposed model.
Going with the flow: using species-discharge relationships to forecast losses in fish biodiversity.
Xenopoulos, Marguerite A; Lodge, David M
2006-08-01
In response to the scarcity of tools to make quantitative forecasts of the loss of aquatic species from anthropogenic effects, we present a statistical model that relates fish species richness to river discharge. Fish richness increases logarithmically with discharge, an index of habitat space, similar to a species-area curve in terrestrial systems. We apply the species-discharge model as a forecasting tool to build scenarios of changes in riverine fish richness from climate change, water consumption, and other anthropogenic drivers that reduce river discharge. Using hypothetical reductions in discharges (of magnitudes that have been observed in other rivers), we predict that reductions of 20-90% in discharge would result in losses of 2-38% of the fish species in two biogeographical regions in the United States (Lower Ohio-Upper Mississippi and Southeastern). Additional data on the occurrence of specific species relative to specific discharge regimes suggests that fishes found exclusively in high discharge environments (e.g., Shovelnose sturgeon) would be most vulnerable to reductions in discharge. Lag times in species extinctions after discharge reduction provide a window of opportunity for conservation efforts. Applications of the species-discharge model can help prioritize such management efforts among species and rivers.
Gandara, Esteban; Ungar, Jonathan; Lee, Jason; Chan-Macrae, Myrna; O'Malley, Terrence; Schnipper, Jeffrey L
2010-06-01
Effective communication among physicians during hospital discharge is critical to patient care. Partners Healthcare (Boston) has been engaged in a multi-year process to measure and improve the quality of documentation of all patients discharged from its five acute care hospitals to subacute facilities. Partners first engaged stakeholders to develop a consensus set of 12 required data elements for all discharges to subacute facilities. A measurement process was established and later refined. Quality improvement interventions were then initiated to address measured deficiencies and included education of physicians and nurses, improvements in information technology, creation of or improvements in discharge documentation templates, training of hospitalists to serve as role models, feedback to physicians and their service chiefs regarding reviewed cases, and case manager review of documentation before discharge. To measure improvement in quality as a result of these efforts, rates of simultaneous inclusion of all 12 applicable data elements ("defect-free rate") were analyzed over time. Some 3,101 discharge documentation packets of patients discharged to subacute facilities from January 1, 2006, through September 2008 were retrospectively studied. During the 11 monitored quarters, the defect-free rate increased from 65% to 96% (p < .001 for trend). The largest improvements were seen in documentation of preadmission medication lists, allergies, follow-up, and warfarin information. Institution of rigorous measurement, feedback, and multidisciplinary, multimodal quality improvement processes improved the inclusion of data elements in discharge documentation required for safe hospital discharge across a large integrated health care system.
An experimental system for symmetric capacitive rf discharge studies
NASA Astrophysics Data System (ADS)
Godyak, V. A.; Piejak, R. B.; Alexandrovich, B. M.
1990-09-01
An experimental system has been designed and built to comprehensively study the electrical and plasma characteristics in symmetric capacitively coupled rf discharges at low gas pressures. Descriptions of the system concept, the discharge chamber, the vacuum-gas control system, and the rf matching and electrical measurement system are presented together with some results of electrical measurements carried out in an argon discharge at 13.56 MHz. The system has been specifically designed to facilitate external discharge parameter measurements and probe measurements and to be compatible with a wide variety of other diagnostics. External electrical measurements and probe measurements within the discharge show that it is an ideal vehicle to study low-pressure rf discharge physics. Measurements from this system should be comparable to one-dimensional rf symmetric capacitive discharge theories and may help to verify them. Although only a few results are given here, the system has been operated reliably over a wide range of gas pressures and should give reproducible and accurate results for discharge electrical characteristics and plasma parameters over a wide range of driving frequency and gas components.
Raabe, Ellen; Stonehouse, David; Ebersol, Kristin; Holland, Kathryn; Robbins, Lisa
2011-01-01
Along the Gulf Coast of Florida north of Tampa Bay lies a region characterized by an open marsh coast, low topographic gradient, water-bearing limestone, and scattered springs. The Floridan aquifer system is at or near land surface in this region, discharging water at a consistent 70-72°F. The thermal contrast between ambient water and aquifer discharge during winter months can be distinguished using airborne thermal-infrared imagery. An airborne thermal-infrared mapping system was used to collect imagery along 126 miles of the Gulf Coast from Jefferson to Levy County, FL, in March 2009. The imagery depicts a large number of discharge locations and associated warm-water plumes in ponds, creeks, rivers, and nearshore waters. A thermal contrast of 6°F or more was set as a conservative threshold for identifying sites, statistically significant at the 99% confidence interval. Almost 900 such coastal and submarine-discharge locations were detected, averaging seven to nine per mile along this section of coast. This represents approximately one hundred times the number of previously known discharge sites in the same area. Several known coastal springs in Taylor and Levy Counties were positively identified with the imagery and were used to estimate regional discharge equivalent to one 1st-order spring, discharging 100 cubic feet per second or more, for every two miles of coastline. The number of identified discharge sites is a conservative estimate and may represent two-thirds of existing features due to low groundwater levels at time of overflight. The role of aquifer discharge in coastal and estuarine health is indisputable; however, mapping and quantifying discharge in a complex karst environment can be an elusive goal. The results of this effort illustrate the effectiveness of the instrument and underscore the influence of coastal springs along this stretch of the Florida coast.
NPDES (National Pollution Discharge & Elimination System) Minor Dischargers
As authorized by the Clean Water Act, the National Pollutant Discharge Elimination System (NPDES) permit program controls water pollution by regulating point sources that discharge pollutants into waters of the United States. The NPDES permit program regulates direct discharges from municipal and industrial wastewater treatment facilities that discharge directly into surface waters. The NPDES permit program is part of the Permit Compliance System (PCS) which issues, records, tracks, and regulates point source discharge facilities. Individual homes that are connected to a municipal system, use a septic system, or do not have a surface discharge do not need an NPDES permit. Facilities in PCS are identified as either major or minor. Within the major/minor classification, facilities are grouped into municipals or non-municipals. In many cases, non-municipals are industrial facilities. This data layer contains Minor dischargers. Major municipal dischargers include all facilities with design flows of greater than one million gallons per day; minor dischargers are less that one million gallons per day. Essentially, a minor discharger does not meet the discharge criteria for a major. Since its introduction in 1972, the NPDES permit program is responsible for significant improvements to our Nation's water quality.
Power Plant Bromide Discharges and Downstream Drinking Water Systems in Pennsylvania.
Good, Kelly D; VanBriesen, Jeanne M
2017-10-17
Coal-fired power plants equipped with wet flue gas desulfurization (FGD) systems have been implicated in increasing bromide levels and subsequent increases in disinfection byproducts at downstream drinking water plants. Bromide was not included as a regulated constituent in the recent steam electric effluent limitations guidelines and standards (ELGs) since the U.S. EPA analysis suggested few drinking water facilities would be affected by bromide discharges from power plants. The present analysis uses a watershed approach to identify Pennsylvania drinking water intakes downstream of wet FGD discharges and to assess the potential for bromide discharge effects. Twenty-two (22) public drinking water systems serving 2.5 million people were identified as being downstream of at least one wet FGD discharge. During mean August conditions (generally low-flow, minimal dilution) in receiving rivers, the median predicted bromide concentrations contributed by wet FGD at Pennsylvania intake locations ranged from 5.2 to 62 μg/L for the Base scenario (including only natural bromide in coal) and from 16 to 190 μg/L for the Bromide Addition scenario (natural plus added bromide for mercury control); ranges depend on bromide loads and receiving stream dilution capacity.
Effects of gas temperature on NO(x) removal by dielectric barrier discharge.
Wang, Tao; Sun, Bao-Min; Xiao, Hai-Ping
2013-01-01
The purpose of this investigation is to discuss the effect of gas temperature on NO(x) removal by dielectric barrier discharge. The Boltzmann equation was used to analyse the electron distribution function in the reactor, and experiments were conducted to find out the effects of different temperatures. The calculation results show that, with a rise in the temperature, E/N increases, increasing the ionization rate. When the ratio of electric field strength to total gas density (E/N) rises from 50 to 150 Td, the ionization rate and electron mean energy increase by 2.0 x 10(5) and 2.3, respectively. The experiments show that in the NO/N2 system, when the temperature increases to 1 30 degrees C and the applied voltage is 11.1 kV, the discharge power is 44.7 W, which is higher than the discharge power of 35.4 W found at 25 degrees C; in the NO/O2/N2 system, an increase in the temperature increases the decomposition of active O3 species, producing a negative effect on NO oxidation; in the NO/O2/N2/C2H4 system, when the temperature increases, the quantity of active species HO2 increases and the NO removal reaction rate increases, reflecting an obvious improvement in the NO removal; and in the NO/O2/N2/C2H4/H2O system, at 25 degrees C, 90 degrees C, and 130 degrees C, when the energy density is 239.7 J L(-1), the NO removal efficiencies are 52.8%, 66.4%, and 71.0%, respectively.
Improvement of growth rate of plants by bubble discharge in water
NASA Astrophysics Data System (ADS)
Takahata, Junichiro; Takaki, Koichi; Satta, Naoya; Takahashi, Katsuyuki; Fujio, Takuya; Sasaki, Yuji
2015-01-01
The effect of bubble discharge in water on the growth rate of plants was investigated experimentally for application to plant cultivation systems. Spinach (Spinacia oleracea), radish (Raphanus sativus var. sativus), and strawberry (Fragaria × ananassa) were used as specimens to clarify the effect of the discharge treatment on edible parts of the plants. The specimens were cultivated in pots filled with artificial soil, which included chicken manure charcoal. Distilled water was sprayed on the artificial soil and drained through a hole in the pots to a water storage tank. The water was circulated from the water storage tank to the cultivation pots after 15 or 30 min discharge treatment on alternate days. A magnetic compression-type pulsed power generator was used to produce the bubble discharge with a repetition rate of 250 pps. The plant height in the growth phase and the dry weight of the harvested plants were improved markedly by the discharge treatment in water. The soil and plant analyzer development (SPAD) value of the plants also improved in the growth phase of the plants. The concentration of nitrate nitrogen, which mainly contributed to the improvement of the growth rate, in the water increased with the discharge treatment. The Brix value of edible parts of Fragaria × ananassa increased with the discharge treatment. The inactivation of bacteria in the water was also confirmed with the discharge treatment.
[Automatic adjustment control system for DC glow discharge plasma source].
Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning
2011-03-01
There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.
Atmospheric Pressure Plasma Induced Sterilization and Chemical Neutralization
NASA Astrophysics Data System (ADS)
Garate, Eusebio; Evans, Kirk; Gornostaeva, Olga; Alexeff, Igor; Lock Kang, Weng; Wood, Thomas K.
1998-11-01
We are studying chemical neutralization and surface decontamination using atmospheric pressure plasma discharges. The plasma is produced by corona discharge from an array of pins and a ground plane. The array is constructed so that various gases, like argon or helium, can be flowed past the pins where the discharge is initiated. The pin array can be biased using either DC, AC or pulsed discharges. Results indicate that the atmospheric plasma is effective in sterilizing surfaces with biological contaminants like E-coli and bacillus subtilus cells. Exposure times of less than four minutes in an air plasma result in a decrease in live colony counts by six orders of magnitude. Greater exposure times result in a decrease of live colony counts of up to ten orders of magnitude. The atmospheric pressure discharge is also effective in decomposing organic phosphate compounds that are simulants for chemical warfare agents. Details of the decomposition chemistry, by-product formation, and electrical energy consumption of the system will be discussed.
Tahmasebian, Shahram; Langarizadeh, Mostafa; Ghazisaeidi, Marjan; Mahdavi-Mazdeh, Mitra
2016-01-01
Introduction: Case-based reasoning (CBR) systems are one of the effective methods to find the nearest solution to the current problems. These systems are used in various spheres as well as industry, business, and economy. The medical field is not an exception in this regard, and these systems are nowadays used in the various aspects of diagnosis and treatment. Methodology: In this study, the effective parameters were first extracted from the structured discharge summary prepared for patients with chronic kidney diseases based on data mining method. Then, through holding a meeting with experts in nephrology and using data mining methods, the weights of the parameters were extracted. Finally, fuzzy system has been employed in order to compare the similarities of current case and previous cases, and the system was implemented on the Android platform. Discussion: The data on electronic discharge records of patients with chronic kidney diseases were entered into the system. The measure of similarity was assessed using the algorithm provided in the system, and then compared with other known methods in CBR systems. Conclusion: Developing Clinical fuzzy CBR system used in Knowledge management framework for registering specific therapeutic methods, Knowledge sharing environment for experts in a specific domain and Powerful tools at the point of care. PMID:27708490
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
33 CFR 157.12 - Oil discharge monitoring and control system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Oil discharge monitoring and... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12 Oil discharge monitoring and control system. (a) Each vessel must have an oil discharge monitoring and control system (monitoring system) that...
1991-05-01
schedule for construction, upgrading or operation of wastewater treatment facilities or any other environmental programs, which may effect storm water quality of...if the storm water quality may be similar. c. Two sets of samples are required to be collected: (1) A grab during the first 30 minutes of the rainfall
Nanoscale discharge electrode for minimizing ozone emission from indoor corona devices.
Bo, Zheng; Yu, Kehan; Lu, Ganhua; Mao, Shun; Chen, Junhong; Fan, Fa-Gung
2010-08-15
Ground-level ozone emitted from indoor corona devices poses serious health risks to the human respiratory system and the lung function. Federal regulations call for effective techniques to minimize the indoor ozone production. In this work, stable atmospheric corona discharges from nanomaterials are demonstrated using horizontally suspended carbon nanotubes (CNTs) as the discharge electrode. Compared with the conventional discharges employing micro- or macroscale electrodes, the corona discharge from CNTs could initiate and operate at a much lower voltage due to the small electrode diameter, and is thus energy-efficient. Most importantly, the reported discharge is environmentally friendly since no ozone (below the detection limit of 0.5 ppb) was detected for area current densities up to 0.744 A/m(2) due to the significantly reduced number of electrons and plasma volume generated by CNT discharges. The resulting discharge current density depends on the CNT loading. Contrary to the conventional wisdom, negative CNT discharges should be used to enhance the current density owing to the efficient field emission of electrons from the CNT surface.
A Study of the Effects of Detergents on Typical Bilge Waters and Correlation of Oil Particle Sizes
1975-07-01
Code 15 Supplementary Notet 1 T v/atei6. Abstract il removal systems for treating bilge r are drastically affected by the condi- tion...to develop effi cient oil removal systems for treating discharged bilgewaters. The oil -removi ng efficiency of any oil-water separator is grossly...difficulty i n removal from the bilge water during or prior to discharge. However, all bil~es are usually collection point s for other var ious a ~ 1
Stability of backwater-influenced river bifurcations: A study of the Mississippi-Atchafalaya system
NASA Astrophysics Data System (ADS)
Edmonds, D. A.
2012-04-01
In this paper I use numerical modeling to show that the hydraulic backwater profile creates a feedback that may stabilize river bifurcations. The numerical model simulates flow and sediment transport in the Mississippi-Atchafalaya River system without the Old River Control Structure. The results show that bifurcation evolution strongly depends on the discharge upstream of the bifurcation. At upstream discharges greater than 12600 m3 s-1 the Atchafalaya River discharge increases through time at the expense of the Mississippi River. Interestingly, at upstream discharges lower than 12600 m3 s-1 the opposite occurs and the Mississippi River discharge increases at the expense of the Atchafalaya River. The capture direction changes because the backwater profile of each river varies enough at high and low discharge to invert the water surface slope ratio. These results suggest that the capture direction would change at high and low flow, which would have a stabilizing effect by preventing the runaway growth of one channel. Accounting for this, I calculate that in the absence of the Old River Control Structure capture would not happen catastrophically, but rather the Atchafalaya River would capture the Mississippi River in ˜300 years from present day.
Analysis and design of a high power, digitally-controlled spacecraft power system
NASA Technical Reports Server (NTRS)
Lee, F. C.; Cho, B. H.
1990-01-01
The progress to date on the analysis and design of a high power, digitally controlled spacecraft power system is described. Several battery discharger topologies were compared for use in the space platform application. Updated information has been provided on the battery voltage specification. Initially it was thought to be in the 30 to 40 V range. It is now specified to be 53 V to 84 V. This eliminated the tapped-boost and the current-fed auto-transformer converters from consideration. After consultations with NASA, it was decided to trade-off the following topologies: (1) boost converter; (2) multi-module, multi-phase boost converter; and (3) voltage-fed push-pull with auto-transformer. A non-linear design optimization software tool was employed to facilitate an objective comparison. Non-linear design optimization insures that the best design of each topology is compared. The results indicate that a four-module, boost converter with each module operating 90 degrees out of phase is the optimum converter for the space platform. Large-signal and small-signal models were generated for the shunt, charger, discharger, battery, and the mode controller. The models were first tested individually according to the space platform power system specifications supplied by NASA. The effect of battery voltage imbalance on parallel dischargers was investigated with respect to dc and small-signal responses. Similarly, the effects of paralleling dischargers and chargers were also investigated. A solar array and shunt model was included in these simulations. A model for the bus mode controller (power control unit) was also developed to interface the Orbital replacement Unit (ORU) model to the platform power system. Small signal models were used to generate the bus impedance plots in the various operating modes. The large signal models were integrated into a system model, and time domain simulations were performed to verify bus regulation during mode transitions. Some changes have subsequently been incorporated into the models. The changes include the use of a four module boost discharger, and a new model for the mode controller, which includes the effects of saturation. The new simulations for the boost discharger show the improvement in bus ripple that can be achieved by phase-shifted operation of each of the boost modules.
42 CFR 412.4 - Discharges and transfers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...
42 CFR 412.4 - Discharges and transfers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...
42 CFR 412.4 - Discharges and transfers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...
42 CFR 412.4 - Discharges and transfers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...
42 CFR 412.4 - Discharges and transfers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES General Provisions § 412.4 Discharges... hospital inpatient is considered discharged from a hospital paid under the prospective payment system when... the initial discharge) to another hospital that is— (1) Paid under the prospective payment system...
Simpson, Michael R.; Oltmann, Richard N.
1993-01-01
Discharge measurement of large rivers and estuaries is difficult, time consuming, and sometimes dangerous. Frequently, discharge measurements cannot be made in tide-affected rivers and estuaries using conventional discharge-measurement techniques because of dynamic discharge conditions. The acoustic Doppler discharge-measurement system (ADDMS) was developed by the U.S. Geological Survey using a vessel-mounted acoustic Doppler current profiler coupled with specialized computer software to measure horizontal water velocity at 1-meter vertical intervals in the water column. The system computes discharge from water-and vessel-velocity data supplied by the ADDMS using vector-algebra algorithms included in the discharge-measurement software. With this system, a discharge measurement can be obtained by engaging the computer software and traversing a river or estuary from bank to bank; discharge in parts of the river or estuarine cross sections that cannot be measured because of ADDMS depth limitations are estimated by the system. Comparisons of ADDMS-measured discharges with ultrasonic-velocity-meter-measured discharges, along with error-analysis data, have confirmed that discharges provided by the ADDMS are at least as accurate as those produced using conventional methods. In addition, the advantage of a much shorter measurement time (2 minutes using the ADDMS compared with 1 hour or longer using conventional methods) has enabled use of the ADDMS for several applications where conventional discharge methods could not have been used with the required accuracy because of dynamic discharge conditions.
Characteristics of electromagnetic interference generated by arc discharges. [in spacecraft
NASA Technical Reports Server (NTRS)
Leung, Philip
1986-01-01
Electromagnetic interference (EMI) signatures resulting from arc discharges are characterized, and the effects of electrostatic discharges (ESDs) on the design of spacecraft systems are investigated. EMI characterization experiments were performed on Mylar, Teflon, Kapton, fused silica, and fiberglass in a vacuum chamber with acrylic walls; the experimental design and procedures are described. Discharge current pulses and RF spectra generated by the sample materials are examined. The relation between the magnitude of EMI generated during an ESD event and the material, environment, and geometry is studied. The solar-array/plasma interaction is analyzed; particular attention is given to the rate of discharge as a function of plasma density. The physical mechanisms of ESD-generated EMI are discussed. The data reveal that ESD parameters are dependent on the test environment.
Tillman, F.D.; Callegary, J.B.; Nagler, P.L.; Glenn, E.P.
2012-01-01
Groundwater is a vital water resource in the arid to semi-arid southwestern United States. Accurate accounting of inflows to and outflows from the groundwater system is necessary to effectively manage this shared resource, including the important outflow component of groundwater discharge by vegetation. A simple method for estimating basin-scale groundwater discharge by vegetation is presented that uses remote sensing data from satellites, geographic information systems (GIS) land cover and stream location information, and a regression equation developed within the Southern Arizona study area relating the Enhanced Vegetation Index from the MODIS sensors on the Terra satellite to measured evapotranspiration. Results computed for 16-day composited satellite passes over the study area during the 2000 through 2007 time period demonstrate a sinusoidal pattern of annual groundwater discharge by vegetation with median values ranging from around 0.3 mm per day in the cooler winter months to around 1.5 mm per day during summer. Maximum estimated annual volume of groundwater discharge by vegetation was between 1.4 and 1.9 billion m3 per year with an annual average of 1.6 billion m3. A simplified accounting of the contribution of precipitation to vegetation greenness was developed whereby monthly precipitation data were subtracted from computed vegetation discharge values, resulting in estimates of minimum groundwater discharge by vegetation. Basin-scale estimates of minimum and maximum groundwater discharge by vegetation produced by this simple method are useful bounding values for groundwater budgets and groundwater flow models, and the method may be applicable to other areas with similar vegetation types.
Lequerica, Anthony; Krch, Denise; Lengenfelder, Jean; Chiaravalloti, Nancy; Arango-Lasprilla, Juan Carlos; Hammond, Flora M; O'Neil-Pirozzi, Therese M; Perrin, Paul B; Sander, Angelle M
2015-01-01
To examine the effect of primary language on admission and discharge FIM™ communication ratings in a sample of individuals with moderate-to-severe traumatic brain injury (TBI). Secondary data analysis of rehabilitation admission and discharge FIM™ communication ratings of 2795 individuals hospitalized at a Traumatic Brain Injury Model Systems (TBIMS) centre between 2007-2012. Individuals who spoke no English were rated worse on functional communication outcomes at inpatient rehabilitation discharge relative to individuals whose primary language was English. These findings may reflect systematic bias in FIM™ communication ratings of non-English-speaking individuals with TBI and/or TBI-induced communication difficulties in non-English-speaking individuals. Clinical and research implications are discussed.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Yim, John; Herman, Daniel; Peterson, Peter Y.; Williams, George J.; Gilland, James; Hofer, Richard; Mikellides, Ioannis
2016-01-01
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front magnetic pole cover thruster configuration with the thruster body electrically tied to cathode, and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68% and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the discharge current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability were mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 1×10-5 Torr-Xe (for thruster flow rates of 20.5 mg/s). Power spectral density analysis of the discharge current waveforms showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant breathing mode frequency. Finally, IVB maps of the TDU-1 thruster indicated that the discharge current became more oscillatory with higher discharge current peak-to-peak and RMS values with increased facility background pressure at lower thruster mass flow rates; thruster operation at higher flow rates resulted in less change to the thruster's IVB characteristics with elevated background pressure.
RECENT DEVELOPMENTS IN HYDROLOGIC INSTRUMENTATION.
Latkovich, Vito J.
1985-01-01
The availability of space-age materials and implementation of state-of-the-art electronics is making possible the recent developments of hydrologic instrumentation. Material developments include: Synthetic-fiber sounding and tag lines; fiberglass wading rod; polymer (plastic) sheaves, pulleys and sampler components; and polymer (plastic) bucket wheels for current meters. These materials are very cost effective and efficient. Electromechanical and electronic developments and applications include: adaptable data acquisition system; downhole sampler for hazardous substances; current-meter digitizer; hydraulic power/drive system for discharge measurements and water-quality sampling; non-contact water-level sensors; minimum data recorder; acoustic velocity meters, and automated current meter discharge-measurement system.
NASA Technical Reports Server (NTRS)
Trouong, Long V.; Wolff, Frederic J.; Dravid, Narayan V.; Li, Ponlee
2000-01-01
Replacement of one module of the battery charge discharge unit (BCDU) of the International Space Station (ISS) by a flywheel energy storage unit (FESU) is under consideration. Integration of these two dissimilar systems is likely to surface difficulties in areas of system stability and fault protection. Other issues that need to be addressed include flywheel charge and discharge profiles and their effect on the ISS power system as well as filter sizing for power Ability purposes. This paper describes a SABER based simulation to study these issues.
Liquid over-feeding air conditioning system and method
Mei, Viung C.; Chen, Fang C.
1993-01-01
A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant.
Smith, Kenneth J; Handler, Steven M; Kapoor, Wishwa N; Martich, G Daniel; Reddy, Vivek K; Clark, Sunday
2016-07-01
This study sought to determine the effects of automated primary care physician (PCP) communication and patient safety tools, including computerized discharge medication reconciliation, on discharge medication errors and posthospitalization patient outcomes, using a pre-post quasi-experimental study design, in hospitalized medical patients with ≥2 comorbidities and ≥5 chronic medications, at a single center. The primary outcome was discharge medication errors, compared before and after rollout of these tools. Secondary outcomes were 30-day rehospitalization, emergency department visit, and PCP follow-up visit rates. This study found that discharge medication errors were lower post intervention (odds ratio = 0.57; 95% confidence interval = 0.44-0.74; P < .001). Clinically important errors, with the potential for serious or life-threatening harm, and 30-day patient outcomes were not significantly different between study periods. Thus, automated health system-based communication and patient safety tools, including computerized discharge medication reconciliation, decreased hospital discharge medication errors in medically complex patients. © The Author(s) 2015.
Singlet oxygen generation in gas discharge for oxygen-iodine laser pumping
NASA Astrophysics Data System (ADS)
Lopaev, D. V.; Braginsky, O. V.; Klopovsky, K. S.; Kovalev, A. S.; Mankelevich, Yu. A.; Popov, N. A.; Rakhimov, A. T.; Rakhimova, T. V.; Vasilieva, A. N.
2004-09-01
The possibility of development of effective discharged singlet oxygen (SO) generator (DSOG) for oxygen-iodine laser (OIL) is studied in detail. Researches of kinetics of oxygen atoms and oxygen molecules in the lowest metastable singlet states have been carried out in the different discharges and its afterglow (DC discharges, E-beam controlled discharge and RF discharges) in both CW and pulsed mode in a wide range of conditions (pressures, gas mixtures, energy deposits etc.). The models developed for all the discharges have allowed us to analyze SO generation and loss mechanisms and to find out the key-parameters controlling the highest SO yield. It is shown that in addition to spatial plasma uniformity at low E/N and high specific energy deposit per oxygen molecule, DSOG must be oxygen atom free to avoid fast three-body quenching of SO by atomic oxygen with increasing pressure and thereby to provide pressure scaling (in tens Torrs) for applying to real OIL systems.
Study of runaway electrons using the conditional average sampling method in the Damavand tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pourshahab, B., E-mail: bpourshahab@gmail.com; Sadighzadeh, A.; Abdi, M. R., E-mail: r.abdi@phys.ui.ac.ir
2017-03-15
Some experiments for studying the runaway electron (RE) effects have been performed using the poloidal magnetic probes system installed around the plasma column in the Damavand tokamak. In these experiments, the so-called runaway-dominated discharges were considered in which the main part of the plasma current is carried by REs. The induced magnetic effects on the poloidal pickup coils signals are observed simultaneously with the Parail–Pogutse instability moments for REs and hard X-ray bursts. The output signals of all diagnostic systems enter the data acquisition system with 2 Msample/(s channel) sampling rate. The temporal evolution of the diagnostic signals is analyzedmore » by the conditional average sampling (CAS) technique. The CASed profiles indicate RE collisions with the high-field-side plasma facing components at the instability moments. The investigation has been carried out for two discharge modes—low-toroidal-field (LTF) and high-toroidal-field (HTF) ones—related to both up and down limits of the toroidal magnetic field in the Damavand tokamak and their comparison has shown that the RE confinement is better in HTF discharges.« less
DeSimone, Leslie A.
2004-01-01
Water-supply withdrawals and wastewater disposal in the Assabet River Basin in eastern Massachusetts alter the flow and water quality in the basin. Wastewater discharges and stream-flow depletion from ground-water withdrawals adversely affect water quality in the Assabet River, especially during low-flow months (late summer) and in headwater areas. Streamflow depletion also contributes to loss of aquatic habitat in tributaries to the river. In 19972001, water-supply withdrawals averaged 9.9 million gallons per day (Mgal/d). Wastewater discharges to the Assabet River averaged 11 Mgal/d and included about 5.4 Mgal/d that originated from sources outside of the basin. The effects of current (2004) and future withdrawals and discharges on water resources in the basin were investigated in this study. Steady-state and transient ground-water-flow models were developed, by using MODFLOW-2000, to simulate flow in the surficial glacial deposits and underlying crystalline bedrock in the basin. The transient model simulated the average annual cycle at dynamic equilibrium in monthly intervals. The models were calibrated to 19972001 conditions of water withdrawals, wastewater discharges, water levels, and nonstorm streamflow (base flow plus wastewater discharges). Total flow through the simulated hydrologic system averaged 195 Mgal/d annually. Recharge from precipitation and ground-water discharge to streams were the dominant inflow and outflow, respectively. Evapotranspiration of ground water from wetlands and non-wetland areas also were important losses from the hydrologic system. Water-supply withdrawals and infiltration to sewers averaged 5 and 1.3 percent, respectively, of total annual out-flows and were larger components (12 percent in September) of the hydrologic system during low-flow months. Water budgets for individual tributary and main stem subbasins identified areas, such as the Fort Meadow Brook and the Assabet Main Stem Upper subbasins, where flows resulting from anthropo-genic activities were relatively large percentages, compared to other subbasins, (more than 20 percent in September) of total out-flows. Wastewater flows in the Assabet River accounted for 55, 32, and 20 percent of total nonstorm streamflow (base flow plus wastewater discharge) out of the Assabet Main Stem Upper, Middle, and Lower subbasins, respectively, in an average September. The ground-water-flow models were used to evaluate water-management alternatives by simulating hypothetical scenarios of altered withdrawals and discharges. A scenario that included no water management quantified nonstorm stream-flows that would result without withdrawals, discharges, septic-system return flow, or consumptive use. Tributary flows in this scenario increased in most subbasins by 2 to 44 percent relative to 19972001 conditions. The increases resulted mostly from variable combinations of decreased withdrawals and decreased infiltration to sewers. Average annual nonstorm streamflow in the Assabet River decreased slightly in this scenario, by 2 to 3 percent annually, because gains in ground-water discharge were offset by the elimination of wastewater discharges. A second scenario quantified the effects of increasing withdrawals and discharges to currently permitted levels. In this simulation, average annual tributary flows decreased in most subbasins, by less than 1 to 10 percent relative to 19972001 conditions. In the Assabet River, flows increased slightly, 1 to 5 percent annually, and the percentage of wastewater in the river increased to 69, 42, and 27 percent of total nonstorm streamflow out of the Assabet Main Stem Upper, Middle, and Lower subbasins, respectively, in an average September. A third set of scenarios quantified the effects of ground-water discharge of wastewater at four hypothetical sites, while maintaining 19972000 wastewater discharges to the Assabet River. Wastewater, discharged at a constant rate that varied among sites from 0.3 to 1
Mathew, George; Kho, Abel; Dexter, Paul; Bloodworth, Nathaniel; Fantz, Corinne; Spell, Nathan; LaBorde, David V
2012-06-01
To develop a clinical decision support system activated at the time of discharge to reduce potentially inappropriate discharges from unidentified or unaddressed abnormal laboratory values. We identified 106 laboratory tests for possible inclusion in the discharge alert filter. We selected 7 labs as widely available, commonly obtained, and associated with high risk for potential morbidity or mortality within abnormal ranges. We identified trigger thresholds at levels that would capture significant laboratory abnormalities while avoiding excessive flag generation because of laboratory results that minimally deviate outside the normal reference range. We selected sodium (>155 or <125 mmol/L), potassium (<2.5 or >6 mEq/dL) phosphorous (<1.6 mg/dL), magnesium (<1.2 mg/dL), creatinine greater than 1.1 with a rise of 20% or more between the 2 most recent results, white blood cell count (>11,000 cells/mm with a rise of 20% or more between the 2 most recent results), and international normalized ratio greater than 4. A discharge alert filter that reliably and effectively identifies patients that may be discharged in unsafe situations because of unaddressed critical laboratory values can improve patient safety at discharge and potentially reduce the incidence of costly litigation. Further research is needed to validate whether the proposed discharge alert filter is effective at improving patient safety at discharge.
Contamination enhanced electrostatic discharge mechanisms
NASA Technical Reports Server (NTRS)
Jeffrey, J. A.; Maag, C. R.
1979-01-01
The two problems of enhanced electrostatic discharge (ESD) and contamination are discussed. It is shown that there is a synergistic relationship between them such that one enhances the probability of occurance of the other. The action of both provides substantially more deleterious affects than the effects of both separately. Mechanisms for such a relationship are discussed as well as application to large advanced technology systems.
Jellyfish Stings and Their Management: A Review
Cegolon, Luca; Heymann, William C.; Lange, John H.; Mastrangelo, Giuseppe
2013-01-01
Jellyfish (cnidarians) have a worldwide distribution. Despite most being harmless, some species may cause local and also systemic reactions. Treatment of jellyfish envenomation is directed at: alleviating the local effects of venom, preventing further nematocyst discharges and controlling systemic reactions, including shock. In severe cases, the most important step is stabilizing and maintaining vital functions. With some differences between species, there seems to be evidence and consensus on oral/topical analgesics, hot water and ice packs as effective painkillers and on 30 s application of domestic vinegar (4%–6% acetic acid) to prevent further discharge of unfired nematocysts remaining on the skin. Conversely, alcohol, methylated spirits and fresh water should be carefully avoided, since they could massively discharge nematocysts; pressure immobilization bandaging should also be avoided, as laboratory studies show that it stimulates additional venom discharge from nematocysts. Most treatment approaches are presently founded on relatively weak evidence; therefore, further research (especially randomized clinical trials) is strongly recommended. Dissemination of appropriate treatment modalities should be deployed to better inform and educate those at risk. Adequate signage should be placed at beaches to notify tourists of the jellyfish risk. Swimmers in risky areas should wear protective equipment. PMID:23434796
2009-09-01
observed today, it is discussed further in Section 1.1. In addition to the work done in propulsion with coaxial electro thermal pulse plasma thrusters (PPTs...initial plasma conditions. The literature supported these findings for more basic laboratory capillaries, but the effect on a thruster device was unknown...An in- depth investigation of different ignition systems were conducted for a capillary discharge based pulsed plasma thruster. In addition to
Effective discharge analysis of ecological processes in streams
Doyle, Martin W.; Stanley, Emily H.; Strayer, David L.; Jacobson, Robert B.; Schmidt, John C.
2005-01-01
Discharge is a master variable that controls many processes in stream ecosystems. However, there is uncertainty of which discharges are most important for driving particular ecological processes and thus how flow regime may influence entire stream ecosystems. Here the analytical method of effective discharge from fluvial geomorphology is used to analyze the interaction between frequency and magnitude of discharge events that drive organic matter transport, algal growth, nutrient retention, macroinvertebrate disturbance, and habitat availability. We quantify the ecological effective discharge using a synthesis of previously published studies and modeling from a range of study sites. An analytical expression is then developed for a particular case of ecological effective discharge and is used to explore how effective discharge varies within variable hydrologic regimes. Our results suggest that a range of discharges is important for different ecological processes in an individual stream. Discharges are not equally important; instead, effective discharge values exist that correspond to near modal flows and moderate floods for the variable sets examined. We suggest four types of ecological response to discharge variability: discharge as a transport mechanism, regulator of habitat, process modulator, and disturbance. Effective discharge analysis will perform well when there is a unique, essentially instantaneous relationship between discharge and an ecological process and poorly when effects of discharge are delayed or confounded by legacy effects. Despite some limitations the conceptual and analytical utility of the effective discharge analysis allows exploring general questions about how hydrologic variability influences various ecological processes in streams.
White, M.A.; Schmidt, J.C.; Topping, D.J.
2005-01-01
Wavelet analysis is a powerful tool with which to analyse the hydrologic effects of dam construction and operation on river systems. Using continuous records of instantaneous discharge from the Lees Ferry gauging station and records of daily mean discharge from upstream tributaries, we conducted wavelet analyses of the hydrologic structure of the Colorado River in Grand Canyon. The wavelet power spectrum (WPS) of daily mean discharge provided a highly compressed and integrative picture of the post-dam elimination of pronounced annual and sub-annual flow features. The WPS of the continuous record showed the influence of diurnal and weekly power generation cycles, shifts in discharge management, and the 1996 experimental flood in the post-dam period. Normalization of the WPS by local wavelet spectra revealed the fine structure of modulation in discharge scale and amplitude and provides an extremely efficient tool with which to assess the relationships among hydrologic cycles and ecological and geomorphic systems. We extended our analysis to sections of the Snake River and showed how wavelet analysis can be used as a data mining technique. The wavelet approach is an especially promising tool with which to assess dam operation in less well-studied regions and to evaluate management attempts to reconstruct desired flow characteristics. Copyright ?? 2005 John Wiley & Sons, Ltd.
Brooks, Steven J; Harman, Christopher; Grung, Merete; Farmen, Eivind; Ruus, Anders; Vingen, Sjur; Godal, Brit F; Barsiene, Janina; Andreikenaite, Laura; Skarpheðinsdottir, Halldóra; Liewenborg, Birgitta; Sundt, Rolf C
2011-01-01
The Norwegian water column monitoring program investigates the biological effects of offshore oil and gas activities in Norwegian waters. In three separate surveys in 2006, 2008, and 2009, bioaccumulation and biomarker responses were measured in mussels (Mytilus edulis) and Atlantic cod (Gadus morhua) held in cages at known distances from the produced water (PW) discharge at the Ekofisk oil field. Identical monitoring studies performed in all three years have allowed the biological effects and bioaccumulation data to be compared, and in addition, enabled the potential environmental benefits of a PW treatment system (CTour), implemented in 2008, to be evaluated. The results of the 2009 survey showed that caged animals were exposed to low levels of PW components, with highest tissue concentrations in mussels located closest to the PW discharge. Mussels located approximately 1-2 km away demonstrated only background concentrations of target compounds. Concentrations of polycyclic aromatic hydrocarbons (PAH) and alkyl phenol (AP) metabolites in the bile of caged cod were elevated at stations 200-250 m from the discharge. There was also a signal of exposure relative to discharge for the biomarkers CYP1A in fish and micronuclei in mussels. All other fish and mussel biomarkers showed no significant exposure effects in 2009. The mussel bioaccumulation data in 2009 indicated a lower exposure to the PW effluent than seen previously in 2008 and 2006, resulting in an associated general improvement in the health of the caged mussels. This was due to the reduction in overall discharge of PW components (measured as oil in water) into the area in 2009 compared to previous years as a result of the improved PW treatment system.
Plasma breakdown in a capacitively-coupled radiofrequency argon discharge
NASA Astrophysics Data System (ADS)
Smith, H. B.; Charles, C.; Boswell, R. W.
1998-10-01
Low pressure, capacitively-coupled rf discharges are widely used in research and commercial ventures. Understanding of the non-equilibrium processes which occur in these discharges during breakdown is of interest, both for industrial applications and for a deeper understanding of fundamental plasma behaviour. The voltage required to breakdown the discharge V_brk has long been known to be a strong function of the product of the neutral gas pressure and the electrode seperation (pd). This paper investigates the dependence of V_brk on pd in rf systems using experimental, computational and analytic techniques. Experimental measurements of V_brk are made for pressures in the range 1 -- 500 mTorr and electrode separations of 2 -- 20 cm. A Paschen-style curve for breakdown in rf systems is developed which has the minimum breakdown voltage at a much smaller pd value, and breakdown voltages which are significantly lower overall, than for Paschen curves obtained from dc discharges. The differences between the two systems are explained using a simple analytic model. A Particle-in-Cell simulation is used to investigate a similar pd range and examine the effect of the secondary emission coefficient on the rf breakdown curve, particularly at low pd values. Analytic curves are fitted to both experimental and simulation results.
A systematic review of the cost and cost-effectiveness of electronic discharge communications
Sevick, Laura K; Esmail, Rosmin; Tang, Karen; Lorenzetti, Diane L; Ronksley, Paul; James, Matthew; Santana, Maria; Ghali, William A; Clement, Fiona
2017-01-01
Background The transition between acute care and community care can be a vulnerable period in a patients’ treatment due to the potential for postdischarge adverse events. The vulnerability of this period has been attributed to factors related to the miscommunication between hospital-based and community-based physicians. Electronic discharge communication has been proposed as one solution to bridge this communication gap. Prior to widespread implementation of these tools, the costs and benefits should be considered. Objective To establish the cost and cost-effectiveness of electronic discharge communications compared with traditional discharge systems for individuals who have completed care with one provider and are transitioning care to a new provider. Methods We conducted a systematic review of the published literature, using best practices, to identify economic evaluations/cost analyses of electronic discharge communication tools. Inclusion criteria were: (1) economic analysis and (2) electronic discharge communication tool as the intervention. Quality of each article was assessed, and data were summarised using a component-based analysis. Results One thousand unique abstracts were identified, and 57 full-text articles were assessed for eligibility. Four studies met final inclusion criteria. These studies varied in their primary objectives, methodology, costs reported and outcomes. All of the studies were of low to good quality. Three of the studies reported a cost-effectiveness measure ranging from an incremental daily cost of decreasing average discharge note completion by 1 day of $0.331 (2003 Canadian), a cost per page per discharge letter of €9.51 and a dynamic net present value of €31.1 million for a 5-year implementation of the intervention. None of the identified studies considered clinically meaningful patient or quality outcomes. Discussion Economic analyses of electronic discharge communications are scarcely reported, and with inconsistent methodology and outcomes. Further studies are needed to understand the cost-effectiveness and value for patient care. PMID:28674136
Xu, Zuxin; Xiong, Lijun; Li, Huaizheng; Liao, Zhengliang; Yin, Hailong; Wu, Jun; Xu, Jin; Chen, Hao
2017-04-01
For storm drainages inappropriately connected with sewage, wet weather discharge is a major factor that adversely affects receiving waters. A study of the wet weather influences of rainfall-discharge variables on storm drainages connected with sewage was conducted in the downtown Shanghai area (374 ha). Two indicators, event mean concentration (EMC) and event pollutant load per unit area (EPL), were used to describe the pollution discharge during 20 rain events. The study showed that the total rainfall and discharge volume were important factors that affect the EMCs and EPLs of the chemical oxygen demand, total phosphorus, and especially those of NH 4 + -N. The pollutant concentrations at the beginning of the discharge and the discharge period were also major factors that influence the EMCs of these three pollutants. Regression relationships between the rainfall-discharge variables and discharge volume/ EPLs (R 2 = 0.824-0.981) were stronger than the relationships between the rainfall-discharge variables and EMCs. These regression equations can be considered reliable in the system, with a relative validation error of less than ±10% for the discharge volume, and less than ±20% for the EPLs. The results presented in this paper provide guidance for effectively controlling pollution in similar storm drainages.
Murla, Damian; Gutierrez, Oriol; Martinez, Montse; Suñer, David; Malgrat, Pere; Poch, Manel
2016-04-15
During heavy rainfall, the capacity of sewer systems and wastewater treatment plants may be surcharged producing uncontrolled wastewater discharges and a depletion of the environmental quality. Therefore there is a need of advanced management tools to tackle with these complex problems. In this paper an environmental decision support system (EDSS), based on the integration of mathematical modeling and knowledge-based systems, has been developed for the coordinated management of urban wastewater systems (UWS) to control and minimize uncontrolled wastewater spills. Effectiveness of the EDSS has been tested in a specially designed virtual UWS, including two sewers systems, two WWTP and one river subjected to typical Mediterranean rain conditions. Results show that sewer systems, retention tanks and wastewater treatment plants improve their performance under wet weather conditions and that EDSS can be very effective tools to improve the management and prevent the system from possible uncontrolled wastewater discharges. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Wenjuan; Gu, Zhenyu; Teng, Fuhua; Lu, Jianhai; Dong, Shibi; Miao, Xiaoping; Wu, Zhongbiao
2018-06-01
The degradation of xylene in the dielectric barrier discharge plasma and photocatalyst process was studied, focusing on the synergetic effect of UV rays from plasma process and external UV lamps on the decomposition of xylene. The results showed that xylene could be decomposed by the discharge process in plasma system, whereas the UV rays from plasma process was very weak. After adding TiO2, the removal efficiency of xylene and energy yield in plasma process were enhanced since energetic particles activated the catalysis of TiO2. The removal efficiency of xylene and energy field in plasma and photocatalyst process combined with external UV lamps were further enhanced attributed to the degradation effect of plasma, the catalysis of TiO2 activated by plasma, the photolysis of UV rays and the photocatalysis of photocatalyst. The synergetic effect of UV rays from external UV lamps was obvious.
Space Environment Effects on Materials : An Overview
NASA Technical Reports Server (NTRS)
Garrett, Henry B.
2006-01-01
A general overview on the space environment and its effects on materials is presented. The topics include: 1) Impact of Space Effects on Spacecraft Costs; 2) Space Environment Effects on Spacecraft by Source; 3) Primary Source of Space Effects: The Sun; 4) The Earth's Environment; 5) Trapped Radiation Belts; 6) Aurora Are Everywhere; 7) Spacecraft Interactions; 8) Atmospheric Effects; 9) Contaminant Effects on Materials; 10) Meteoroid/Debris Effects on Materials; 11) Spacecraft Surface Charging; 12) Surface Discharge Effects; 13) Internal Electrostatic Discharge--Satellite Killer; 14) Plasma Interactions DS-1 Ion Engines; 15) Radiation Effects on Spacecraft Systems and Materials; 16) Total Ionizing Dose Effects Total Ionizing Dose Effects; 17) Man-Made Sources of Space Effects Man-Made Sources of Space Effects; and 18) Space Environments Versus Interactions.
Scale effects and a method for similarity evaluation in micro electrical discharge machining
NASA Astrophysics Data System (ADS)
Liu, Qingyu; Zhang, Qinhe; Wang, Kan; Zhu, Guang; Fu, Xiuzhuo; Zhang, Jianhua
2016-08-01
Electrical discharge machining(EDM) is a promising non-traditional micro machining technology that offers a vast array of applications in the manufacturing industry. However, scale effects occur when machining at the micro-scale, which can make it difficult to predict and optimize the machining performances of micro EDM. A new concept of "scale effects" in micro EDM is proposed, the scale effects can reveal the difference in machining performances between micro EDM and conventional macro EDM. Similarity theory is presented to evaluate the scale effects in micro EDM. Single factor experiments are conducted and the experimental results are analyzed by discussing the similarity difference and similarity precision. The results show that the output results of scale effects in micro EDM do not change linearly with discharge parameters. The values of similarity precision of machining time significantly increase when scaling-down the capacitance or open-circuit voltage. It is indicated that the lower the scale of the discharge parameter, the greater the deviation of non-geometrical similarity degree over geometrical similarity degree, which means that the micro EDM system with lower discharge energy experiences more scale effects. The largest similarity difference is 5.34 while the largest similarity precision can be as high as 114.03. It is suggested that the similarity precision is more effective in reflecting the scale effects and their fluctuation than similarity difference. Consequently, similarity theory is suitable for evaluating the scale effects in micro EDM. This proposed research offers engineering values for optimizing the machining parameters and improving the machining performances of micro EDM.
Converse, Kathryn A.
1995-01-01
Wetlands accumulate pollutants from adjacent areas through intentional discharge of sewage or industrial wastes, runoff of agricultural fertilizers and pesticides, and discharge from municipal storm drains. Coastal wetlands receive more pollutants indirectly as the endpoint for upland drainage systems and directly through petroleum spills and insect abatement. Wetlands that serve as evaporation basins during seasonally high water, especially in more arid climates, concentrate natural compounds and as well as pollutants. The ability of wetlands to be effective filtration systems for wastewater nutrients through microbial transformations, uptake by plants, and deposition of particulate matter, and the shortage of water in arid climates has resulted in revision of wetland regulations. Wetlands can now be developed for wastewater treatment and natural wetlands can be restored or converted to wastewater treatment systems. The effect of these accumulation pollutants on wetland ecology and wildlife health needs to be recognized.
Acoustic Doppler discharge-measurement system
Simpson, Michael R.; Oltmann, Richard N.; ,
1990-01-01
A discharge-measurement system that uses a vessel-mounted acoustic Doppler current profiler has been developed and tested by the U.S. Geological Survey. Discharge measurements using the system require a fraction of the time needed for conventional current-meter discharge measurements and do not require shore-based navigational aids or tag lines for positioning the vessel.
NASA Astrophysics Data System (ADS)
Audier, P.; Fénot, M.; Bénard, N.; Moreau, E.
2016-02-01
The case presented here deals with plasma flow control applied to a cross-flow configuration, more specifically to a film cooling system. The ability of a plasma dielectric barrier discharge actuator for film cooling effectiveness enhancement is investigated through an experimental set-up, including a film injection from an elongated slot into a thermally uniform cross-flow. Two-dimensional particle image velocimetry and infrared-thermography measurements are performed for three different blowing ratios of M = 0.4, 0.5, and 1. Results show that the effectiveness can be increased when the discharge is switched on, as predicted by the numerical results available in literature. Whatever the blowing ratio, the actuator induces a deflection of the jet flow towards the wall, increases its momentum, and delays its diffusion in the cross-flow.
NASA Astrophysics Data System (ADS)
Piliouras, Anastasia; Kim, Wonsuck; Carlson, Brandee
2017-10-01
Vegetation is an important component of constructional landscapes, as plants enhance deposition and provide organic sediment that can increase aggradation rates to combat land loss. We conducted two sets of laboratory experiments using alfalfa (Medicago sativa) to determine the effects of plants on channel organization and large-scale delta dynamics. In the first set, we found that rapid vegetation colonization enhanced deposition but inhibited channelization via increased form drag that reduced the shear stress available for sediment entrainment and transport. A second set of experiments used discharge fluctuations between flood and base flow (or interflood). Interfloods were critical for reworking the topset via channel incision and lateral migration to create channel relief and prevent rapid plant colonization. These low-flow periods also greatly reduced the topset slope in the absence of vegetation by removing topset sediment and delivering it to the shoreline. Floods decreased relief by filling channels with sediment, resulting in periods of rapid progradation and enhanced aggradation over the topset surface, which was amplified by vegetation. The combination of discharge fluctuations and vegetation thus provided a balance of vertical aggradation and lateral progradation. We conclude that plants can inhibit channelization in depositional systems and that discharge fluctuations encourage channel network organization to naturally balance against aggradation. Thus, variations in discharge are an important aspect of understanding the ecomorphodynamics of aggrading surfaces and modeling vegetated deltaic systems, and the combined influences of plants and discharge variations can act to balance vertical and lateral delta growth.
Investment threshold and management reflection for industrial system cleaning: a case for China.
Fang, Yiping
2012-03-01
The recognition that industrial activity plays an essential role in a sustainable society is now widespread. To understand the causal relationship between industrial pollution abatement expenditure and industrial system cleaning level in China is of considerable importance, especially under extremely rapid industrial growth and serious pressure of industrial pollutants abatement context. We use composite index assessment method and regression analysis in this paper. We establish the mathematical model between composite industrial cleaner index and investment intensity for industrial pollutants abatement, and analyze the effects of industrial pollutants treatment and discharge indicators on composite industrial cleaner index in China. Results show that: (1) There is significant nonlinear relationship between composite industrial cleaner index and investment intensity for industrial pollutants abatement. (2) From single indicator perspective, the effect of investment intensity on pollutants treatment indicators is positively, on the contrary, the effect of investment intensity on pollutants discharge indicators is negatively; (3) From decomposition cleaner index perspective, the effect of pollutants discharge level (process control) is higher than pollutants treatment capacity (end-of-pipe) on composite industrial cleaner index; (4) There is threshold between investment intensity and composite cleaner industrial index, it is a crucial reference scale for industrial environmental management in selected period.
Penetration and Duration of Fuel Sprays from a Pump Injection System
NASA Technical Reports Server (NTRS)
Rothrock, A M; Marsh, E T
1931-01-01
High-speed motion pictures were taken of individual fuel sprays from a pump injection system. The changes in the spray-tip penetration with changes in the pump speed, injection-valve opening and closing pressures, discharge-orifice area, injection-tube length and diameter, and pump throttle setting were measured. In addition, the effects of the variables on the time lag and duration of injection can be controlled by the dimensions of the injection tube, the area of the discharge orifice, and the injection-valve opening and closing pressures.
Bradycardia and asystole during generalised interictal EEG discharges.
Sforza, Emilia; Pichot, Vincent; Gschwind, Markus; Roche, Frédéric; Maeder-Ingvar, Malin
2014-12-01
Few studies have investigated the effects of interictal epileptic discharges on the cardiac autonomic system. This study reports the case of a 37-year-old man with refractory generalised epilepsy, who recently reported an increase in frequency of nocturnal tonic-clonic seizures, not responding to treatment. During the nocturnal video study, in non-rapid eye movements sleep, we recorded 106 generalised sharp- and polyspike-waves lasting for 3 to 7 seconds, associated with bradycardia and asystole, without behavioural changes and without increase in deltoid muscle activity. The asystole had a duration of between 3 and 8 seconds. In one case, a 7 second asystole was associated with a tonic-clonic generalised seizure. A 24-hour electrocardiographic study revealed a bradycardia and a Wenckebach atrioventricular block. Heart rate analysis at the time of the interictal epileptic discharges revealed an abrupt increase in the RR interval, occurring simultaneously with the onset of interictal epileptic discharges and followed by a return to values below baseline value. A cardiac pacemaker was installed with a reduction of asystole length during the interictal epileptic discharges. Our findings indicate, for the first time, the role of interictal generalised discharges in EEG-related asystole and bradycardia. These data support the hypothesis that some patients with epilepsy may be predisposed to disturbances of the autonomic cardiac system.
Foster Care Dynamics and System Science: Implications for Research and Policy.
Wulczyn, Fred; Halloran, John
2017-10-05
Although system is a word frequently invoked in discussions of foster care policy and practice, there have been few if any attempts by child welfare researchers to understand the ways in which the foster care system is a system. As a consequence, insights from system science have yet to be applied in meaningful ways to the problem of making foster care systems more effective. In this study, we draw on population biology to organize a study of admissions and discharges to foster care over a 15-year period. We are interested specifically in whether resource constraints, which are conceptualized here as the number of beds, lead to a coupling of admissions and discharges within congregate care. The results, which are descriptive in nature, are consistent with theory that ties admissions and discharges together because of a resource constraint. From the data, it is clear that the underlying system exerts an important constraint on what are normally viewed as individual-level decisions. Our discussion calls on extending efforts to understand the role of system science in studies of child welfare systems, with a particular emphasis on the role of feedback as a causal influence.
Shon, Changwoo; Chung, Seolhee; Yi, Seonju; Kwon, Soonman
2011-01-01
The purpose of this study was to examine the impact of Diagnosis-Related Group (DRG)-based payment on the length of stay and the number of outpatient visits after discharge in for patients who had undergone caesarean section. This study used the health insurance data of the patients in health care facilities that were paid by the Fee-For-Service (FFS) in 2001-2004, but they participated in the DRG payment system in 2005-2007. In order to examine the net effects of DRG payment, the difference-in-differences (DID) method was adopted to observe the difference in health care utilization before and after the participation in the DRG payment system. The dependent variables of the regression model were the length of stay and number of outpatient visits after discharge, and the explanatory variables included the characteristics of the patients and the health care facilities. The length of stay in DRG-paid health care facilities was greater than that in the FFS-paid ones. Yet, DRG payment has no statistically significant effect on the number of outpatient visits after discharge. The results of this study that DRG payment was not effective in reducing the length of stay can be related to the nature of voluntary participation in the DRG system. Only those health care facilities that are already efficient in terms of the length of stay or that can benefit from the DRG payment may decide to participate in the program.
Love, William J; Lehenbauer, Terry W; Kass, Philip H; Van Eenennaam, Alison L; Aly, Sharif S
2014-01-01
Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized "BRD positive" if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves.
Love, William J.; Lehenbauer, Terry W.; Kass, Philip H.; Van Eenennaam, Alison L.
2014-01-01
Several clinical scoring systems for diagnosis of bovine respiratory disease (BRD) in calves have been proposed. However, such systems were based on subjective judgment, rather than statistical methods, to weight scores. Data from a pair-matched case-control study on a California calf raising facility was used to develop three novel scoring systems to diagnose BRD in preweaned dairy calves. Disease status was assigned using both clinical signs and diagnostic test results for BRD-associated pathogens. Regression coefficients were used to weight score values. The systems presented use nasal and ocular discharge, rectal temperature, ear and head carriage, coughing, and respiratory quality as predictors. The systems developed in this research utilize fewer severity categories of clinical signs, require less calf handling, and had excellent agreement (Kappa > 0.8) when compared to an earlier scoring system. The first scoring system dichotomized all clinical predictors but required inducing a cough. The second scoring system removed induced cough as a clinical abnormality but required distinguishing between three levels of nasal discharge severity. The third system removed induced cough and forced a dichotomized variable for nasal discharge. The first system presented in this study used the following predictors and assigned values: coughing (induced or spontaneous coughing, 2 points), nasal discharge (any discharge, 3 points), ocular discharge (any discharge, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C or 102.5°F, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 95.4% cases and 88.6% controls. The second presented system categorized the predictors and assigned weights as follows: coughing (spontaneous only, 2 points), mild nasal discharge (unilateral, serous, or watery discharge, 3 points), moderate to severe nasal discharge (bilateral, cloudy, mucoid, mucopurlent, or copious discharge, 5 points), ocular discharge (any discharge, 1 point), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥4. This system correctly classified 89.3% cases and 92.8% controls. The third presented system used the following predictors and scores: coughing (spontaneous only, 2 points), nasal discharge (any, 4 points), ocular discharge (any, 2 points), ear and head carriage (ear droop or head tilt, 5 points), fever (≥39.2°C, 2 points), and respiratory quality (abnormal respiration, 2 points). Calves were categorized “BRD positive” if their total score was ≥5. This system correctly classified 89.4% cases and 90.8% controls. Each of the proposed systems offer few levels of clinical signs and data-based weights for on-farm diagnosis of BRD in dairy calves. PMID:24482759
Shan, Bao-Qing; Li, Nan; Tang, Wen-Zhong
2012-11-01
Ecological drainage system (EDS) including ditches, ponds and wetland was constructed at the Paifangchen village on the north of Chaohu Lake, Anhui, and its retention effect on pollution was investigated. With the comprehensive function of sewage discharge, collecting and process, the system could intercept runoff pollutants effectively. The results acquired from 3 rainfall events showed that the retention rates of EDS to TSS, COD, TP and TN were 78.2%, 57.8%, 55.5% and 64.2% respectively, and the concentrations at outflow of the system to TSS, COD, TP and NH4(+) -N were 23.5, 66.3, 0.49 and 3.03 mg x L(-1) separately, met the first standard of "Integrated Wastewater Discharge Standards". Ponds were the important unit of EDS and the daily water quality concentrations of TSS, COD, TP and TN were 28.0, 31.2, 0.47 and 4.65 mg x L(-1) respectively, met the V standard of "Environment Quality Standards for Surface Water" basically.
Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors.
Zhang, Chongxing; Dong, Ming; Ren, Ming; Huang, Wenguang; Zhou, Jierui; Gao, Xuze; Albarracín, Ricardo
2018-02-11
Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of metal-enclosed switchgear. The transient earth voltage method, an effective non-intrusive method, has substantial engineering application value for estimating the insulation condition of switchgear. However, the practical application effectiveness of TEV detection is not satisfactory because of the lack of a TEV detection application method, i.e., a method with sufficient technical cognition and analysis. This paper proposes an innovative online PD detection system and a corresponding application strategy based on an intelligent feedback distributed TEV wireless sensor network, consisting of sensing, communication, and diagnosis layers. In the proposed system, the TEV signal or status data are wirelessly transmitted to the terminal following low-energy signal preprocessing and acquisition by TEV sensors. Then, a central server analyzes the correlation of the uploaded data and gives a fault warning level according to the quantity, trend, parallel analysis, and phase resolved partial discharge pattern recognition. In this way, a TEV detection system and strategy with distributed acquisition, unitized fault warning, and centralized diagnosis is realized. The proposed system has positive significance for reducing the fault rate of medium voltage switchgear and improving its operation and maintenance level.
Effect of Doppler flow meter position on discharge measurement in surcharged manholes.
Yang, Haoming; Zhu, David Z; Liu, Yanchen
2018-02-01
Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.
Insulator edge voltage gradient effects in spacecraft charging phenomena
NASA Technical Reports Server (NTRS)
Stevens, N. J.; Purvis, C. K.; Staskus, J. V.
1978-01-01
Insulating surfaces on geosynchronous satellites were charged by geomagnetic substorms to a point where discharges occur. The electromagnetic pulses from these discharges couple into satellite electronic systems disrupting operations are examined. Laboratory tests conducted on insulator charging have indicated that discharges appear to be initiated at insulator edges where voltage gradients can exist. An experimental investigation was conducted to measure edge voltage gradients on silvered Teflon samples as they are charged by monoenergetic electron beams. It was found that the surface voltage at insulator edges can be approximated by an exponential expression based on an electron current density balance.
Liquid over-feeding air conditioning system and method
Mei, V.C.; Chen, F.C.
1993-09-21
A refrigeration air conditioning system utilizing a liquid over-feeding operation is described. A liquid refrigerant accumulator-heat exchanger is placed in the system to provide a heat exchange relationship between hot liquid refrigerant discharged from condenser and a relatively cool mixture of liquid and vaporous refrigerant discharged from the evaporator. This heat exchange relationship substantially sub-cools the hot liquid refrigerant which undergoes little or no evaporation across the expansion device and provides a liquid over-feeding operation through the evaporator for effectively using 100 percent of evaporator for cooling purposes and for providing the aforementioned mixture of liquid and vaporous refrigerant. 1 figure.
Discharge measurements using a broad-band acoustic Doppler current profiler
Simpson, Michael R.
2002-01-01
The measurement of unsteady or tidally affected flow has been a problem faced by hydrologists for many years. Dynamic discharge conditions impose an unreasonably short time constraint on conventional current-meter discharge-measurement methods, which typically last a minimum of 1 hour. Tidally affected discharge can change more than 100 percent during a 10-minute period. Over the years, the U.S. Geological Survey (USGS) has developed moving-boat discharge-measurement techniques that are much faster but less accurate than conventional methods. For a bibliography of conventional moving-boat publications, see Simpson and Oltmann (1993, page 17). The advent of the acoustic Doppler current profiler (ADCP) made possible the development of a discharge-measurement system capable of more accurately measuring unsteady or tidally affected flow. In most cases, an ADCP discharge-measurement system is dramatically faster than conventional discharge-measurement systems, and has comparable or better accuracy. In many cases, an ADCP discharge-measurement system is the only choice for use at a particular measurement site. ADCP systems are not yet ?turnkey;? they are still under development, and for proper operation, require a significant amount of operator training. Not only must the operator have a rudimentary knowledge of acoustic physics, but also a working knowledge of ADCP operation, the manufacturer's discharge-measurement software, and boating techniques and safety.
Mode transition of a Hall thruster discharge plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hara, Kentaro, E-mail: kenhara@umich.edu; Sekerak, Michael J., E-mail: msekerak@umich.edu; Boyd, Iain D.
2014-05-28
A Hall thruster is a cross-field plasma device used for spacecraft propulsion. An important unresolved issue in the development of Hall thrusters concerns the effect of discharge oscillations in the range of 10–30 kHz on their performance. The use of a high speed Langmuir probe system and ultra-fast imaging of the discharge plasma of a Hall thruster suggests that the discharge oscillation mode, often called the breathing mode, is strongly correlated to an axial global ionization mode. Stabilization of the global oscillation mode is achieved as the magnetic field is increased and azimuthally rotating spokes are observed. A hybrid-direct kinetic simulationmore » that takes into account the transport of electronically excited atoms is used to model the discharge plasma of a Hall thruster. The predicted mode transition agrees with experiments in terms of the mean discharge current, the amplitude of discharge current oscillation, and the breathing mode frequency. It is observed that the stabilization of the global oscillation mode is associated with reduced electron transport that suppresses the ionization process inside the channel. As the Joule heating balances the other loss terms including the effects of wall loss and inelastic collisions, the ionization oscillation is damped, and the discharge oscillation stabilizes. A wide range of the stable operation is supported by the formation of a space charge saturated sheath that stabilizes the electron axial drift and balances the Joule heating as the magnetic field increases. Finally, it is indicated from the numerical results that there is a strong correlation between the emitted light intensity and the discharge current.« less
Estimated discharge of treated wastewater in Florida, 1990
Marella, R.L.
1994-01-01
According to the Florida Department of Environ- mental Protection, 5,100 wastewater treatment systems were in operation during 1990. Of this total, 72 percent were domestic wastewater facilities and 28 percent were industrial waste- water facilities. The number of wastewater systems inventoried for 1990 was 1,062 (systems that treated and discharged more than 0.01 Mgal/d or had a plant capacity of greater than 0.04 Mgal/d. Based on this inventory, the estimated discharge of treated wastewater in Florida during 1990 totaled 1,638 million gallons per day. Approxi- mately 65 percent of this water was discharged to surface water during 1990 and the remaining 35 percent was discharged to ground water. Discharge to surface water includes effluent outfalls into the Atlantic Ocean (32 percent), while the re- maining (68 percent) is discharged into the Gulf of Mexico, bays, rivers, wetlands, and other surface water bodies throughout Florida. Discharge to ground-water includes treated effluent outfalls to land application systems (reuse systems and spray fields), drain fields, percolation ponds (51 percent), and to injection wells (49 percent). An estimated 322 million gallons per day of the treated domestic and industrial wastewater was reused during 1990. Discharge of treated domestic wastewater from the 994 systems inventoried in Florida during 1990 totaled 1,353 million gallons per day and served an estimated 8.58 million people (66 percent of the population of Florida in 1990). The remaining 34 percent of the popu- lation (4.36 million) are served by the 2,700 smaller domestic wastewater systems or have individual septic tanks. In 1990, there were 1.56 million septic tanks in Florida. Discharge of industrial wastewater was inventoried for 68 systems in 1990 and totaled 285 million gallons per day. Discharge of domestic wastewater in- creased more than 20 percent and industrial wastewater discharge increased 5 percent from 1985 to 1990. (USGS)
Control system for 5 MW neutral beam ion source for SST1
NASA Astrophysics Data System (ADS)
Patel, G. B.; Onali, Raja; Sharma, Vivek; Suresh, S.; Tripathi, V.; Bandyopadhyay, M.; Singh, N. P.; Thakkar, Dipal; Gupta, L. N.; Singh, M. J.; Patel, P. J.; Chakraborty, A. K.; Baruah, U. K.; Mattoo, S. K.
2006-01-01
This article describes the control system for a 5MW ion source of the NBI (neutral beam injector) for steady-state superconducting tokamak-1 (SST-1). The system uses both hardware and software solutions. It comprises a DAS (data acquisition system) and a control system. The DAS is used to read the voltage and current signals from eight filament heater power supplies and 24 discharge power supplies. The control system is used to adjust the filament heater current in order to achieve an effective control on the discharge current in the plasma box. The system consists of a VME (Verse Module Eurocard) system and C application program running on a VxWorks™ real-time operating system. A PID (proportional, integral, and differential) algorithm is used to control the filament heater current. Experiments using this system have shown that the discharge current can be controlled within 1% accuracy for a PID loop time of 20ms. Response of the control system to the pressure variation of the gas in the chamber has also been studied and compared with the results obtained from those of an uncontrolled system. The present approach increases the flexibility of the control system. It not only eases the control of the plasma but also allows an easy changeover to various operation scenarios.
Cover cropping to reduce nitrate loss through subsurface drainage in the northern U.S. corn belt.
Strock, J S; Porter, P M; Russelle, M P
2004-01-01
Despite the use of best management practices for nitrogen (N) application rate and timing, significant losses of nitrate nitrogen (NO3(-)-N) in drainage discharge continue to occur from row crop cropping systems. Our objective was to determine whether a autumn-seeded winter rye (Secale cereale L.) cover crop following corn (Zea mays L.) would reduce NO3(-)-N losses through subsurface tile drainage in a corn-soybean [Glycine mar (L.) Merr.] cropping system in the northern Corn Belt (USA) in a moderately well-drained soil. Both phases of the corn-soybean rotation, with and without the winter rye cover crop following corn, were established in 1998 in a Normania clay loam (fine-loamy, mixed, mesic Aquic Haplustoll) soil at Lamberton, MN. Cover cropping did not affect subsequent soybean yield, but reduced drainage discharge, flow-weighted mean nitrate concentration (FWMNC), and NO3(-)-N loss relative to winter fallow, although the magnitude of the effect varied considerably with annual precipitation. Three-year average drainage discharge was lower with a winter rye cover crop than without (p = 0.06). Over three years, subsurface tile-drainage discharge was reduced 11% and NO3(-)-N loss was reduced 13% for a corn-soybean cropping system with a rye cover crop following corn than with no rye cover crop. We estimate that establishment of a winter rye cover crop after corn will be successful in one of four years in southwestern Minnesota. Cover cropping with rye has the potential to be an effective management tool for reducing NO3(-)-N loss from subsurface drainage discharge despite challenges to establishment and spring growth in the north-central USA.
An Apparatus for Measuring Rates of Discharge of a Fuel-Injection System
NASA Technical Reports Server (NTRS)
Dutee, Francis J
1941-01-01
A portable apparatus for rapidly determining rates of discharge of a fuel-injection system is described. Satisfactory operation of this apparatus with injection-pump speeds up to 2400 r.p.m was obtained. Rate-of-discharge tests were made with several cam-plunger-valve injection systems with long injection tubes. A check valve designed to reduce secondary discharges was tested. This check valve was operated with injection-pump speeds up to 2400 r.p.m without the occurrence of large secondary discharges.
Ahm, Malte; Thorndahl, Søren; Nielsen, Jesper E; Rasmussen, Michael R
2016-12-01
Combined sewer overflow (CSO) structures are constructed to effectively discharge excess water during heavy rainfall, to protect the urban drainage system from hydraulic overload. Consequently, most CSO structures are not constructed according to basic hydraulic principles for ideal measurement weirs. It can, therefore, be a challenge to quantify the discharges from CSOs. Quantification of CSO discharges are important in relation to the increased environmental awareness of the receiving water bodies. Furthermore, CSO discharge quantification is essential for closing the rainfall-runoff mass-balance in combined sewer catchments. A closed mass-balance is an advantage for calibration of all urban drainage models based on mass-balance principles. This study presents three different software sensor concepts based on local water level sensors, which can be used to estimate CSO discharge volumes from hydraulic complex CSO structures. The three concepts were tested and verified under real practical conditions. All three concepts were accurate when compared to electromagnetic flow measurements.
A comprehensive inpatient discharge system.
O'Connell, E. M.; Teich, J. M.; Pedraza, L. A.; Thomas, D.
1996-01-01
Our group has developed a computer system that supports all phases of the inpatient discharge process. The system fills in most of the physician's discharge order form and the nurse's discharge abstract, using information available from sign-out, order entry, scheduling, and other databases. It supplies information for referrals to outside institutions, and provides a variety of instruction materials for patients. Discharge forms can be completed in advance, so that the patient is not waiting for final paperwork. Physicians and nurses can work on their components independently, rather than in series. Response to the system has been very favorable. PMID:8947755
Stolp, Bernard J.; Brooks, Lynette E.; Solder, John
2017-03-28
The Malad-Lower Bear River study area in Box Elder County, Utah, consists of a valley bounded by mountain ranges and is mostly agricultural or undeveloped. The Bear and Malad Rivers enter the study area with a combined average flow of about 1,100,000 acre-feet per year (acre-ft/yr), and this surface water dominates the hydrology. Groundwater occurs in consolidated rock and basin fill. Groundwater recharge occurs from precipitation in the mountains and moves through consolidated rock to the basin fill. Recharge occurs in the valley from irrigation. Groundwater discharge occurs to rivers, springs and diffuse seepage areas, evapotranspiration, field drains, and wells. Groundwater, including springs, is a source for municipal and domestic water supply. Although withdrawal from wells is a small component of the groundwater budget, there is concern that additional groundwater development will reduce the amount of flow in the Malad River. Historical records of surface-water diversions, land use, and groundwater levels indicate relatively stable hydrologic conditions from the 1960s to the 2010s, and that current groundwater development has had little effect on the groundwater system. Average annual recharge to and discharge from the groundwater flow system are estimated to be 164,000 and 228,000 acre-ft/yr, respectively. The imbalance between recharge and discharge represents uncertainties resulting from system complexities, and the possibility of groundwater inflow from surrounding basins.This study reassesses the hydrologic system, refines the groundwater budget, and creates a numerical groundwater flow model that is used to analyze the effects of groundwater withdrawals on surface water. The model uses the detailed catalog of locations and amounts of groundwater recharge and discharge defined during this study. Calibrating the model to adequately simulate recharge, discharge, and groundwater levels results in simulated aquifer properties that can be used to understand the relation between pumping and the reduction in discharge to rivers, springs, natural vegetation, and field drains. Simulations run by the calibrated model were used to calculate the reduction of groundwater discharge to the Malad River (stream depletion) in response to a well withdrawal of 360 acre-ft/yr at any location within the study area. Modeling results show that streamflow depletion in the Malad River depends on both depth and location of groundwater withdrawal, and varies from less than 1 percent to 96 percent of the well withdrawal. The relation between simulated withdrawal and reductions in Malad River streamflow, Bear River streamflow, and spring discharge are shown on capture maps.
NASA Astrophysics Data System (ADS)
Rodríguez-Sinobas, L.; Gil-Rodríguez, M.; Sánchez, R.; Losada, A.; Castañón, G.; Juana, L.; Laguna, F. V.; Benítez, J.
2010-05-01
Conventional drip irrigation is considered one of the most efficient irrigation systems. Alternatively to traditional surface drip irrigation systems (DI), laterals are deployed underneath the soil surface, as in subsurface drip irrigation (SDI), leading to a higher potential efficiency, which is of especial interest in places where water is a limited source. The design and management of DI and SDI systems involve selection of an appropriate combination of emitter discharge rate and spacing between emitters and the inlet pressure and irrigation time for any given set of soil, crop, and climatic conditions, as well as understanding the wetted zone pattern around the emitter. Likewise, water distribution is affected by soil hydraulic properties, initial water content, emitter discharge, irrigation frequency, evapotranspiration and root characteristics. However, complexity arousing of soil water properties and soil profile characteristics means that these are often not properly considered in the design and management of those systems. A better understanding of the infiltration process around the discharge point source should contribute to increase water use efficiency and thus to reduce the risk of environmental impact of irrigation. In this regard, numerical models have been proved to be a powerful tool to analyze the evolution of the wetting pattern during the distribution and redistribution processes, in order to explore irrigation management strategies, to set up the duration of irrigation, and finally to optimize water use efficiency. Also, irrigation design variables such as emitter spacing and discharge could also be assessed. In this study the suitability of the HYDRUS-2D to simulate infiltration process around an emitter during irrigation of a loamy soil with drip and SDI laterals has been addressed. The model was then applied in order to evaluate the main dimensions of the wetted soil volume surrounding the emitter during irrigation. Irrigation uniformity with DI and SDI laterals were determined by field evaluations at different inlet head pressures. Results were related with estimations made on water distribution within the soil that were simulated taking into account the emitter discharge at different lateral locations, initial soil water content, soil hydraulic properties and time of irrigation. Conclusions highlight the effect of emitter discharge, emitter spacing, and irrigation time on wetting patterns, and thus solute transport, in both drip and subsurface drip irrigation. The effect of emitter depth was also considered in SDI. Some recommendations for the design and management of these irrigation systems are also provided.
Masterson, John P.
2004-01-01
The U.S. Geological Survey, in cooperation with the National Park Service, Massachusetts Executive Office of Environmental Affairs, Cape Cod Commission, and the Towns of Eastham, Provincetown, Truro, and Wellfleet, began an investigation in 2000 to improve the understanding of the hydrogeology of the four freshwater lenses of the Lower Cape Cod aquifer system and to assess the effects of changing ground-water pumping, recharge conditions, and sea level on ground-water flow in Lower Cape Cod, Massachusetts. A numerical flow model was developed with the computer code SEAWAT to assist in the analysis of freshwater and saltwater flow. Model simulations were used to determine water budgets, flow directions, and the position and movement of the freshwater/saltwater interface. Model-calculated water budgets indicate that approximately 68 million gallons per day of freshwater recharge the Lower Cape Cod aquifer system with about 68 percent of this water moving through the aquifer and discharging directly to the coast, 31 percent flowing through the aquifer, discharging to streams, and then reaching the coast as surface-water discharge, and the remaining 1 percent discharging to public-supply wells. The distribution of streamflow varies greatly among flow lenses and streams; in addition, the subsurface geology greatly affects the position and movement of the underlying freshwater/saltwater interface. The depth to the freshwater/saltwater interface varies throughout the study area and is directly proportional to the height of the water table above sea level. Simulated increases in sea level appear to increase water levels and streamflows throughout the Lower Cape Cod aquifer system, and yet decrease the depth to the freshwater/saltwater interface. The resulting change in water levels and in the depth to the freshwater/saltwater interface from sea-level rise varies throughout the aquifer system and is controlled largely by non-tidal freshwater streams. Pumping from large-capacity municipal-supply wells increases the potential for effects on surface-water bodies, which are affected by pumping and wastewater-disposal locations and rates. Pumping wells that are upgradient of surface-water bodies potentially capture water that would otherwise discharge to these surface-water bodies, thereby reducing streamflow and pond levels. Kettle-hole ponds, such as Duck Pond in Wellfleet, that are near the top of a freshwater flow lens, appear to be more susceptible to changing pumping and recharge conditions than kettle-hole ponds closer to the coast or near discharge boundaries, such as the Herring River.
Massanari, R M; Wilkerson, K; Streed, S A; Hierholzer, W J
1987-01-01
Proper reporting of discharge diagnoses, including complications of medical care, is essential for maximum recovery of revenues under the prospective reimbursement system. To evaluate the effectiveness of abstracting techniques in identifying nosocomial infections at discharge, discharge abstracts of patients with nosocomial infections were reviewed during September through November of 1984. Patients with nosocomial infections were identified using modified Centers for Disease Control (CDC) definitions and trained surveillance technicians. Records which did not include the diagnosis of nosocomial infections in the discharge abstract were identified, and potential lost revenues were estimated. We identified 631 infections in 498 patients. On average, only 57 per cent of the infections were properly recorded and coded in the discharge abstract. Of the additional monies which might be anticipated by the health care institution to assist in the cost of care of adverse events, approximately one-third would have been lost due to errors in coding in the discharge abstract. Although these lost revenues are substantial, they constitute but a small proportion of the potential costs to the institution when patients acquire nosocomial infections. PMID:3105338
Sakson, Grazyna; Brzezinska, Agnieszka; Zawilski, Marek
2018-04-14
Heavy metals are among the priority pollutants which may have toxic effects on receiving water bodies. They are detected in most of samples of stormwater runoff, but the concentrations are very variable. This paper presents results of study on the amount of heavy metals discharged from urban catchment in Lodz (Poland) in 2011-2013. The research was carried out to identify the most important sources of their emission and to assess the threats to receiving water quality and opportunities of their limitation. The city is equipped with a combined sewerage in the center with 18 combined sewer overflows and with separate system in other parts. Stormwater and wastewater from both systems are discharged into 18 small urban rivers. There is a need of restoration of water bodies in the city. Research results indicate that the main issue is high emission of heavy metals, especially zinc and copper, contained in stormwater. Annual mass loads (g/ha/year) from separate system were 1629 for Zn and 305 for Cu. It was estimated that about 48% of the annual load of Zn, 38% of Cu, 61% of Pb, and 40% of Cd discharged into receiving water came from separate system, respectively 4% of Zn and Cu, 10% of Pb and 11% of Cd from CSOs, and the remaining part from wastewater treatment plant. Effective reduction of heavy metals loads discharged into receiving water requires knowledge of sources and emissions for each catchment. Obtained data may indicate the need to apply centralized solution or decentralized by source control.
The mechanism of nickel ferrite formation by glow discharge effect
NASA Astrophysics Data System (ADS)
Frolova, L. A.
2018-04-01
The influence of various factors on the formation of nickel ferrite by the glow discharge effect has been studied. The ferritization process in the system FeSO4-NiSO4-NaOH-H2O has been studied by the methods of potentiometric titration, measurement of electrical conductivity, residual concentrations and apparent sediment volume. It has been established that the process proceeds in a multistage fashion at pH 11-12 with the formation of polyhydroxo complexes, an intermediate compound and the ferrite formation by its oxidation with active radicals.
Image registration for a UV-Visible dual-band imaging system
NASA Astrophysics Data System (ADS)
Chen, Tao; Yuan, Shuang; Li, Jianping; Xing, Sheng; Zhang, Honglong; Dong, Yuming; Chen, Liangpei; Liu, Peng; Jiao, Guohua
2018-06-01
The detection of corona discharge is an effective way for early fault diagnosis of power equipment. UV-Visible dual-band imaging can detect and locate corona discharge spot at all-weather condition. In this study, we introduce an image registration protocol for this dual-band imaging system. The protocol consists of UV image denoising and affine transformation model establishment. We report the algorithm details of UV image preprocessing, affine transformation model establishment and relevant experiments for verification of their feasibility. The denoising algorithm was based on a correlation operation between raw UV images, a continuous mask and the transformation model was established by using corner feature and a statistical method. Finally, an image fusion test was carried out to verify the accuracy of affine transformation model. It has proved the average position displacement error between corona discharge and equipment fault at different distances in a 2.5m-20 m range are 1.34 mm and 1.92 mm in the horizontal and vertical directions, respectively, which are precise enough for most industrial applications. The resultant protocol is not only expected to improve the efficiency and accuracy of such imaging system for locating corona discharge spot, but also supposed to provide a more generalized reference for the calibration of various dual-band imaging systems in practice.
Application of effective discharge analysis to environmental flow decision-making
McKay, S. Kyle; Freeman, Mary C.; Covich, A.P.
2016-01-01
Well-informed river management decisions rely on an explicit statement of objectives, repeatable analyses, and a transparent system for assessing trade-offs. These components may then be applied to compare alternative operational regimes for water resource infrastructure (e.g., diversions, locks, and dams). Intra- and inter-annual hydrologic variability further complicates these already complex environmental flow decisions. Effective discharge analysis (developed in studies of geomorphology) is a powerful tool for integrating temporal variability of flow magnitude and associated ecological consequences. Here, we adapt the effectiveness framework to include multiple elements of the natural flow regime (i.e., timing, duration, and rate-of-change) as well as two flow variables. We demonstrate this analytical approach using a case study of environmental flow management based on long-term (60 years) daily discharge records in the Middle Oconee River near Athens, GA, USA. Specifically, we apply an existing model for estimating young-of-year fish recruitment based on flow-dependent metrics to an effective discharge analysis that incorporates hydrologic variability and multiple focal taxa. We then compare three alternative methods of environmental flow provision. Percentage-based withdrawal schemes outcompete other environmental flow methods across all levels of water withdrawal and ecological outcomes.
Application of Effective Discharge Analysis to Environmental Flow Decision-Making.
McKay, S Kyle; Freeman, Mary C; Covich, Alan P
2016-06-01
Well-informed river management decisions rely on an explicit statement of objectives, repeatable analyses, and a transparent system for assessing trade-offs. These components may then be applied to compare alternative operational regimes for water resource infrastructure (e.g., diversions, locks, and dams). Intra- and inter-annual hydrologic variability further complicates these already complex environmental flow decisions. Effective discharge analysis (developed in studies of geomorphology) is a powerful tool for integrating temporal variability of flow magnitude and associated ecological consequences. Here, we adapt the effectiveness framework to include multiple elements of the natural flow regime (i.e., timing, duration, and rate-of-change) as well as two flow variables. We demonstrate this analytical approach using a case study of environmental flow management based on long-term (60 years) daily discharge records in the Middle Oconee River near Athens, GA, USA. Specifically, we apply an existing model for estimating young-of-year fish recruitment based on flow-dependent metrics to an effective discharge analysis that incorporates hydrologic variability and multiple focal taxa. We then compare three alternative methods of environmental flow provision. Percentage-based withdrawal schemes outcompete other environmental flow methods across all levels of water withdrawal and ecological outcomes.
NASA Astrophysics Data System (ADS)
Abou Zakhem, Boulos; Kattaa, Bassam
2017-10-01
The effects of climate change and overexploitation are being strongly perceived in the studied area and the springs discharge is obviously affected. In this paper, Ras El Ain spring discharge and precipitation were analyzed by normalized methods on an yearly timescale. The deficit of Ras El Ain spring discharge due to overexploitation factors and drought effects was estimated. Cumulative drought analyses were carried out using SPI10 and SQI10. Finally, the decreasing trends of the spring discharge due to the deficiency in rainfall were analyzed. The main results reveal that the annual mean deficit of Ras El Ain spring discharge due to overpumping was between 32 and 45%, whereas, annual mean deficit related to drought was between 22 and 35% on average, during the last 30 years (post-1984). The moving averages of SPI and SQI delineate very well the drought periods during last three decades. The cumulative droughts using SPI10 and SQI10 reveal that wet period (pre-1984) with positive values was characterized by high precipitation and spring discharge. Overexploitation period (1984-1989) is distinguished by decreasing SQI10 values whereas, SPI10 is almost stable. The response of the karst system to the precipitation signal has been changed, during the drought period (1990-2000), and the spring behaviour has been modified due to the first overexploitation period. Finally, overexploitation period (2001-2008) is related to the second phase of groundwater intensive pumping for irrigation purposes. Consequently, this period is completely catastrophic causing the drying up of the spring. The decreasing trends analyzed using DPI and DQI showed annual decreasing rates relative to the mean values of -0.268% and -0.105%, respectively. Thus, the results of theoretical model reveal that precipitation will decrease by about DPI = -20.7% and the discharge will decline by about -9.2% by 2050. Consequently, the declining discharge due to climatic variation under natural conditions as pre-1984 was about 10%. Whereas, the catastrophic drying up of the spring was probably the consequence of the anthropogenic effects. Accordingly, it requires the development of sustainable water resources management program to reduce long-term drought risks, restore the groundwater reservoir and minimize the overexploitation effects on spring discharge.
A neurophysiologic model for aggressive behavior in the cat.
Andy, O J; Giurintano, L P; Giurintano, S L
1978-01-01
A neurophysiologic model for aggressive behavior in the cat is proposed. Stimulus-bound and seizure-bound aggression was evaluated in relation to limbic and basal ganglia induced seizures (after-discharges). Electrically induced limbic and basal ganglia after-discharges were used because they are known to implicate septohypothalamic sites from which aggression can be elicited by direct stimulation. The occurrence of behavioral aggression is correlated with the discharge characteristics of a single discharging system and with two interacting discharging systems. Aggression is composed of autonomic and somato-motor components which poses relatively low and high thresholds, respectively, for their activation. Aggression occurring during a combined septum and amygdala discharge was more intense and prolonged than with a septum discharge alone. Participation of a slow frequency discharging basal ganglia system activated seizure-bound aggression in an otherwise nonaggressive limbic seizure. The limbic and basal ganglia stimulations and after-discharges lowered the excitability threshold of the aggression system and made it more vulnerable to being activated by external stimuli, such as visual and auditory stimuli. These observations are reminiscent of patients with aggressive behavior associated with psychomotor seizures.
Wicklein, S.M.; Gain, W.S.
1999-01-01
The St. Sebastian River lies in the southern part of the Indian River basin on the east coast of Florida. Increases in freshwater discharge due to urbanization and changes in land use have reduced salinity in the St. Sebastian River and, consequently, salinity in the Indian River, affecting the commercial fishing industry. Wind, water temperature, tidal flux, freshwater discharge, and downstream salinity all affect salinity in the St. Sebastian River estuary, but freshwater discharge is the only one of these hydrologic factors which might be affected by water-management practices. A probability analysis of salinity conditions in the St. Sebastian River estuary, taking into account the effects of freshwater discharge over a period from May 1992 to March 1996, was used to determine the likelihood (probability) that salinities, as represented by daily mean specific- conductance values, will fall below a given threshold. The effects of freshwater discharge on salinities were evaluated with a simple volumetric model fitted to time series of measured specific conductance, by using nonlinear optimization techniques. Specific-conductance values for two depths at monitored sites represent stratified flow which results from differences in salt concentration between freshwater and saltwater. Layering of freshwater and saltwater is assumed, and the model is applied independently to each layer with the assumption that the water within the layer is well mixed. The model of specific conductance as a function of discharge (a salinity response model) was combined with a model of residual variation to produce a total probability model. Flow distributions and model residuals were integrated to produce a salinity distribution and determine differences in salinity probabilities as a result of changes in water-management practices. Two possible management alternatives were analyzed: stormwater detention (reducing the peak rate of discharge but not reducing the overall flow volume) and stormwater retention (reducing peak discharges without later release). Detention of freshwater discharges increased the probability of specific- conductance values falling below a given limit (20,000 microsiemens per centimeter) for all sites but one. The retention of freshwater input to the system decreased the likelihood of falling below a selected limit of specific conductance at all sites. For limits of specific conductance (1,000 microsiemens per centimeter or 20,000 microsiemens per centimeter, depending on the site), the predicted days of occurrence below a limit decreased ranging from 17 to 68 percent of the predicted days of occurrence for unregulated flow. The primary finding to be drawn from the discharge-salinity analysis is that an empirical-response model alone does not provide adequate information to assess the response of the system to changes in flow regime. Whether a given level of discharge can produce a given response on a given day is not as important as the probability of that response on a given day and over a period of many days. A deterministic model of the St. Sebastian River estuary based only on discharge would predict that retention of discharge peaks should increase the average salinity conditions in the St. Sebastian River estuary. The probabilistic model produces a very different response indicating that salinity can decrease by a power of three as discharges increase, and that random factors can predominate and control salinity until discharges increase sufficiently to flush the entire system of saltwater.
Low-Cost, High-Performance Hall Thruster Support System
NASA Technical Reports Server (NTRS)
Hesterman, Bryce
2015-01-01
Colorado Power Electronics (CPE) has built an innovative modular PPU for Hall thrusters, including discharge, magnet, heater and keeper supplies, and an interface module. This high-performance PPU offers resonant circuit topologies, magnetics design, modularity, and a stable and sustained operation during severe Hall effect thruster current oscillations. Laboratory testing has demonstrated discharge module efficiency of 96 percent, which is considerably higher than current state of the art.
Brown, Larry R.; Bauer, Marissa L.
2010-01-01
Alteration of natural flow regimes is generally acknowledged to have negative effects on native biota; however, methods for defining ecologically appropriate flow regimes in managed river systems are only beginning to be developed. Understanding how past and present water management has affected rivers is an important part of developing such tools. In this paper, we evaluate how existing hydrologic infrastructure and management affect streamflow characteristics of rivers in the Central Valley, California and discuss those characteristics in the context of habitat requirements of native and alien fishes. We evaluated the effects of water management by comparing observed discharges with estimated discharges assuming no water management ("full natural runoff"). Rivers in the Sacramento River drainage were characterized by reduced winter–spring discharges and augmented discharges in other months. Rivers in the San Joaquin River drainage were characterized by reduced discharges in all months but particularly in winter and spring. Two largely unaltered streams had hydrographs similar to those based on full natural runoff of the regulated rivers. The reduced discharges in the San Joaquin River drainage streams are favourable for spawning of many alien species, which is consistent with observed patterns of fish distribution and abundance in the Central Valley. However, other factors, such as water temperature, are also important to the relative success of native and alien resident fishes. As water management changes in response to climate change and societal demands, interdisciplinary programs of research and monitoring will be essential for anticipating effects on fishes and to avoid unanticipated ecological outcomes.
Discharge planning in mental health care: an integrative review of the literature.
Nurjannah, Intansari; Mills, Jane; Usher, Kim; Park, Tanya
2014-05-01
To identify the evidence base related to discharge planning in the context of acute and community mental healthcare service provision to ascertain the need for future research. Discharge planning is an important activity when preparing consumers to transition from hospital to home. The efficiency of discharge planning for consumers living with a mental health issue can influence both the number of future readmissions to acute-care facilities and their quality of life at home. An integrative review of the peer-reviewed literature. This review uses specific search terms and a 21-year time frame to search two key nursing databases CINAHL (Cinahl Information Systems, Glendale, CA, USA) and PSYCHINFO (American Psychological Association, Washington, DC, USA) for research reports investigating the substantive area of enquiry. Hand searches of reference lists and author searches were also conducted. Nineteen peer-reviewed journal articles met the inclusion criteria for this review. Research findings about discharge planning for people living with a mental health issue identify the importance of communication between health professionals, consumers and their families to maximise the effectiveness of this process. The complexity of consumer's healthcare needs influences the discharge planning process and impacts on aftercare compliance and readmission rates. There is a limited amount of research findings relating to differences between health professionals and families' perceptions of the level of information required for effective discharge planning, and the appropriate level of involvement of individuals living with a mental health issue in their own discharge planning. Results from this integrative review will inform future research related to this topic. Discharge planning for consumers living with a mental health issue involves many stakeholders who have different expectations regarding the type of information required and the necessary level of involvement of people living with a mental health issue in this process. Comprehensive discharge planning can result in reduced readmissions to both acute and community mental health services. Understanding the impact of effective communication on the outcomes of discharge planning is an important step in promoting success. © 2013 John Wiley & Sons Ltd.
Effects of an Internally-Mounted Cathode on Hall Thruster Plume Properties
NASA Technical Reports Server (NTRS)
Hofer, Richard R.; Johnson, Lee K.; Goebel, Dan M.; Fitzgerald, Dennis J.
2006-01-01
The effects of cathode position on the plume properties of an 8 kW BHT-8000 Busek Hall thruster are discussed. Experiments were conducted at the Jet Propulsion Laboratory (JPL) in a vacuum chamber suitable for the development and qualification of high-power Hall thrusters. Multi-mode Hall thruster operation was demonstrated at operating conditions ranging from 200-500 V discharge voltage, 10-40 A discharge current, and 2-8 kW discharge power. Reductions in plume divergence and increased near-field plume symmetries were found to result from the use of an internally-mounted cathode instead of the traditional externally-mounted configuration. High-current hollow cathodes developed at JPL utilizing lanthanum hexaboride (LaB6) emitters were also demonstrated. Discharge currents up to 100 A were achieved with the cathode operating alone and up to 40 A during operation with the Hall thruster. LaB6 cathodes were investigated because of their potential to reduce overall system cost and risk due to less stringent xenon purity and handling requirements.
NASA Astrophysics Data System (ADS)
Zhang, Yanzong; Zheng, Jingtang; Qu, Xianfeng; Yu, Weizhao; Chen, Honggang
2008-06-01
Catalysis and regeneration efficiency of granular activated carbon (GAC) and activated carbon fiber (ACF) were investigated in a non-equilibrium plasma water treatment reactor with a combination of pulsed streamer discharge and GAC or ACF. The experimental results show that the degradation efficiency of methyl orange (MO) by the combined treatment can increase 22% (for GAC) and 24% (for ACF) respectively compared to pulsed discharge treatment alone, indicating that the combined treatment has a synergetic effect. The MO degradation efficiency by the combined treatment with pulsed discharge and saturated GAC or ACF can increase 12% and 17% respectively compared to pulsed discharge treatment alone. Both GAC and ACF show catalysis and the catalysis of ACF is prominent. Meanwhile, the regeneration of GAC and ACF are realized in this process. When H2O2 is introduced into the system, the utilization efficiency of ozone and ultraviolet light is improved and the regeneration efficiency of GAC and ACF is also increased.
Yan, Renhua; Li, Lingling; Gao, Junfeng
2018-05-08
Exploring the hydrological regulation of a lowland polder is essential for increasing knowledge regarding the role of polders associated with pumping stations in lowlands. In this study, the Lowland Polder Hydrology and Phosphorus modelling System (PHPS) was applied to the Jianwei polder as a case study for quantifying the regulation effects of a lowland polder with pumping on discharge and phosphorus loads. The results indicate that the polder significantly affected the temporal distribution and annual amount of catchment discharge. Compared with a no-pumping scenario, an agricultural polder with pumping stations generated a sharper discharge hydrograph with higher peak-values and lower minimum-values, as well as an 8.6% reduction in average annual discharge. It also decreased the phosphorus export to downstream water bodies by 5.33 kg/hm 2 /yr because of widespread ditches and ponds, a lower hydraulic gradient, and increased retention times of surface water in ponds. Copyright © 2018 Elsevier B.V. All rights reserved.
Shim, Sung J; Kumar, Arun; Jiao, Roger
2016-01-01
A hospital is considering deploying a radiofrequency identification (RFID) system and setting up a new "discharge lounge" to improve the patient discharge process. This study uses computer simulation to model and compare the current process and the new process, and it assesses the impact of the RFID system and the discharge lounge on the process in terms of resource utilization and time taken in the process. The simulation results regarding resource utilization suggest that the RFID system can slightly relieve the burden on all resources, whereas the RFID system and the discharge lounge together can significantly mitigate the nurses' tasks. The simulation results in terms of the time taken demonstrate that the RFID system can shorten patient wait times, staff busy times, and bed occupation times. The results of the study could prove helpful to others who are considering the use of an RFID system in the patient discharge process in hospitals or similar processes.
Nuclear Power and the Environment.
ERIC Educational Resources Information Center
Dukert, Joseph M.
Described are the major environmental effects resulting from the production of electricity by nuclear power plants. Discussed are effects of waste heat, radioactivity, radioactive waste elimination, costs, and future prospects. Included are diagrams illustrating cooling tower operation, effects of thermal discharge into water systems, radioactive…
Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher
NASA Technical Reports Server (NTRS)
Butz, James R.; Turchi, Craig S.; Kimball, Amanda; McKinnon, Thomas; Riedel, Edward
2010-01-01
A fine-water-mist fire-suppression device has been designed so that it can be discharged uniformly in any orientation via a high-pressure gas propellant. Standard fire extinguishers used while slightly tilted or on their side will not discharge all of their contents. Thanks to the new design, this extinguisher can be used in multiple environments such as aboard low-gravity spacecraft, airplanes, and aboard vehicles that may become overturned prior to or during a fire emergency. Research in recent years has shown that fine water mist can be an effective alternative to Halons now banned from manufacture. Currently, NASA uses carbon dioxide for fire suppression on the International Space Station (ISS) and Halon chemical extinguishers on the space shuttle. While each of these agents is effective, they have drawbacks. The toxicity of carbon dioxide requires that the crew don breathing apparatus when the extinguishers are deployed on the ISS, and Halon use in future spacecraft has been eliminated because of international protocols on substances that destroy atmospheric ozone. A major advantage to the new system on occupied spacecraft is that the discharged system is locally rechargeable. Since the only fluids used are water and nitrogen, the system can be recharged from stores of both carried aboard the ISS or spacecraft. The only support requirement would be a pump to fill the water and a compressor to pressurize the nitrogen propellant gas. This system uses a gaseous agent to pressurize the storage container as well as to assist in the generation of the fine water mist. The portable fire extinguisher hardware works like a standard fire extinguisher with a single storage container for the agents (water and nitrogen), a control valve assembly for manual actuation, and a discharge nozzle. The design implemented in the proof-of-concept experiment successfully extinguished both open fires and fires in baffled enclosures.
Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif
2017-01-01
Introduction Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%–38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. Methods We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Results Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p <0.0001), missing frequency (3.5% to 2.2%, p=0.04), missing strength errors (32.4% to 10.2%, p <0.0001) and legibility (0.7% to 0.2%, p=0.005). E-prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). Conclusion A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive. PMID:28874948
Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif
2017-08-01
Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%-38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p <0.0001), missing frequency (3.5% to 2.2%, p=0.04), missing strength errors (32.4% to 10.2%, p <0.0001) and legibility (0.7% to 0.2%, p=0.005). E-prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive.
NASA Astrophysics Data System (ADS)
Yin, Zelin; Zhang, Ruirui; Tong, Jie; Chen, Xi
2013-12-01
Partial discharges (PDs) are an electrical phenomenon that occurs within a transformer whenever the voltage stress is sufficient to produce ionization in voids or inclusions within a solid dielectric, at conductor/dielectric interfaces, or in bubbles within liquid dielectrics such as oil; high-frequency transient current discharges will then appear repeatedly and will progressively deteriorate the insulation, ultimately leading to breakdown. Fiber sensor has great potential on the partial discharge detection in high-voltage equipment for its immunity to electromagnetic interference and it can take direct measurement in the high voltage equipment. The energy released in PDs produces a number of effects, resulting in flash, chemical and structural changes and electromagnetic emissions and so on. Acoustic PD detection is based on the mechanical pressure wave emitted from the discharge and fluorescent fiber PD detection is based on the emitted light produced by ionization, excitation and recombination processes during the discharge. Both of the two methods have the shortage of weak anti-interference capacity in the physical environment, like thunder or other sound source. In order to avoid the false report, an all-fiber combined PD detection system of the two methods is developed in this paper. In the system the fluorescent fiber PD sensor is considered as a reference signal, three F-P based PD detection sensors are used to both monitor the PD intensity and calculate the exact position of the discharge source. Considering the wave band of the F-P cavity and the fluorescent probe are quite different, the reflection spectrum of the F-P cavity is in the infrared region, however the fluorescent probe is about 600nm to 700nm, thus the F-P sensor and fluorescent fiber probe can be connected in one fiber and the reflection light can be detected by two different detectors without mutual interference. The all-fiber partial discharge monitoring system not only can detect the PDs but also can ensure the position of the PD source and is of great anti-interference capacity in harsh environment.
Test stand for gas-discharge chamber of TEA CO2 lasers with pulse-periodical energy supply
NASA Astrophysics Data System (ADS)
Shorin, Vladimyr P.; Bystrov, N. D.; Zhuravlyov, O. A.; Nekrasov, V. V.
1997-05-01
Test stand for function optimization (incomposition of gas- dynamic circuit (GDC) of operating characteristics of full- size discharge chamber of flowing TEA carbon-dioxide lasers (power up to 100 kW) was created in Samara State Aerospace University (former Kuibyshev Aviation Institute). Test stand includes an inside-type GDC, low inductive generators of voltage pulses of preionization and main discharges, two-flow rate system of gas supply and noise immunity diagnostic system. Module construction of units of GDC, power supplies of preionization and main discharges allows to change configuration of stand's systems for providing given properties of gas flow and its energy supply. This test stand can also be used in servicing of laser system. The diagnostic system of this stand allows us to analyze energy properties of discharge by means of oscillographic measurements of voltage and current with following processing of discharges' volt- ampere characteristics by means of a computer; rate of non- stationary gas-dynamic disturbances in discharge gap of discharge chamber was measured by means of pulse holographic system (UlG-1M) with data processing of schliren- and interferogram (density fluctuation sensitivity approximately 10-2) and sensor measurement system of gas-dynamic shock and acoustics process with resonance frequency exceeding 100 kHz. Research results of process of plasma plate wave and channel structures interaction with mediums, including actuation non-stationary gas-dynamic flows, cavitation erosion of preionization electrodes' dielectric substructure, ancillary heating of channels by main volumetric discharge are presented as well.
Warne, A.G.; Toth, L.A.; White, W.A.
2000-01-01
Major controls on the retention, distribution, and discharge of surface water in the historic (precanal) Kissimmee drainage basin and river were investigated to determine reference conditions for ecosystem restoration. Precanal Kissimmee drainage-basin hydrology was largely controlled by landforms derived from relict, coastal ridge, lagoon, and shallow-shelf features; widespread carbonate solution depressions; and a poorly developed fluvial drainage network. Prior to channelization for flood control, the Kissimmee River was a very low gradient, moderately meandering river that flowed from Lake Kissimmee to Lake Okeechobee through the lower drainage basin. We infer that during normal wet seasons, river discharge rapidly exceeded Lake Okeechobee outflow capacity, and excess surface water backed up into the low-gradient Kissimmee River. This backwater effect induced bankfull and peak discharge early in the flood cycle and transformed the flood plain into a shallow aquatic system with both lacustrine and riverine characteristics. The large volumes of surface water retained in the lakes and wetlands of the upper basin maintained overbank flow conditions for several months after peak discharge. Analysis indicates that most of the geomorphic work on the channel and flood plain occurred during the frequently recurring extended periods of overbank discharge and that discharge volume may have been significant in determining channel dimensions. Comparison of hydrogeomorphic relationships with other river systems identified links between geomorphology and hydrology of the precanal Kissimmee River. However, drainage-basin and hydraulic geometry models derived solely from general populations of river systems may produce spurious reference conditions for restoration design criteria.
Generator and Setup for Emulating Exposures of Biological Samples to Lightning Strokes.
Rebersek, Matej; Marjanovic, Igor; Begus, Samo; Pillet, Flavien; Rols, Marie-Pierre; Miklavcic, Damijan; Kotnik, Tadej
2015-10-01
We aimed to develop a system for controlled exposure of biological samples to conditions they experience when lightning strikes their habitats. We based the generator on a capacitor charged via a bridge rectifier and a dc-dc converter, and discharged via a relay, delivering arcs similar to natural lightning strokes in electric current waveform and similarly accompanied by acoustic shock waves. We coupled the generator to our exposure chamber described previously, measured electrical and acoustic properties of arc discharges delivered, and assessed their ability to inactivate bacterial spores. Submicrosecond discharges descended vertically from the conical emitting electrode across the air gap, entering the sample centrally and dissipating radially toward the ring-shaped receiving electrode. In contrast, longer discharges tended to short-circuit the electrodes. Recording at 341 000 FPS with Vision Research Phantom v2010 camera revealed that initial arc descent was still vertical, but became accompanied by arcs leaning increasingly sideways; after 8-12 μs, as the first of these arcs formed direct contact with the receiving electrode, it evolved into a channel of plasmified air and short-circuited the electrodes. We eliminated this artefact by incorporating an insulating cylinder concentrically between the electrodes, precluding short-circuiting between them. While bacterial spores are highly resistant to electric pulses delivered through direct contact, we showed that with arc discharges accompanied by an acoustic shock wave, spore inactivation is readily obtained. The presented system allows scientific investigation of effects of arc discharges on biological samples. This system will allow realistic experimental studies of lightning-triggered horizontal gene transfer and assessment of its role in evolution.
Piliouras, Anastasia; Kim, Wonsuck; Carlson, Brandee
2017-10-04
Vegetation is an important component of constructional landscapes, as plants enhance deposition and provide organic sediment that can increase aggradation rates to combat land loss. We conducted two sets of laboratory experiments using alfalfa ( Medicago sativa) to determine the effects of plants on channel organization and large-scale delta dynamics. In the first set, we found that rapid vegetation colonization enhanced deposition but inhibited channelization via increased form drag that reduced the shear stress available for sediment entrainment and transport. A second set of experiments used discharge fluctuations between flood and base flow (or interflood). Interfloods were critical for reworkingmore » the topset via channel incision and lateral migration to create channel relief and prevent rapid plant colonization. These low flow periods also greatly reduced the topset slope in the absence of vegetation by removing topset sediment and delivering it to the shoreline. Floods decreased relief by filling channels with sediment, resulting in periods of rapid progradation and enhanced aggradation over the topset surface, which was amplified by vegetation. The combination of discharge fluctuations and vegetation thus provided a balance of vertical aggradation and lateral progradation. We conclude that plants can inhibit channelization in depositional systems, and that discharge fluctuations encourage channel network organization to naturally balance against aggradation. Furthermore, variations in discharge are an important aspect of understanding the ecomorphodynamics of aggrading surfaces and modeling vegetated deltaic systems, and the combined influences of plants and discharge variations can act to balance vertical and lateral delta growth.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piliouras, Anastasia; Kim, Wonsuck; Carlson, Brandee
Vegetation is an important component of constructional landscapes, as plants enhance deposition and provide organic sediment that can increase aggradation rates to combat land loss. We conducted two sets of laboratory experiments using alfalfa ( Medicago sativa) to determine the effects of plants on channel organization and large-scale delta dynamics. In the first set, we found that rapid vegetation colonization enhanced deposition but inhibited channelization via increased form drag that reduced the shear stress available for sediment entrainment and transport. A second set of experiments used discharge fluctuations between flood and base flow (or interflood). Interfloods were critical for reworkingmore » the topset via channel incision and lateral migration to create channel relief and prevent rapid plant colonization. These low flow periods also greatly reduced the topset slope in the absence of vegetation by removing topset sediment and delivering it to the shoreline. Floods decreased relief by filling channels with sediment, resulting in periods of rapid progradation and enhanced aggradation over the topset surface, which was amplified by vegetation. The combination of discharge fluctuations and vegetation thus provided a balance of vertical aggradation and lateral progradation. We conclude that plants can inhibit channelization in depositional systems, and that discharge fluctuations encourage channel network organization to naturally balance against aggradation. Furthermore, variations in discharge are an important aspect of understanding the ecomorphodynamics of aggrading surfaces and modeling vegetated deltaic systems, and the combined influences of plants and discharge variations can act to balance vertical and lateral delta growth.« less
Nduwimana, André; Yang, Xiang-Long; Wang, Li-Ren
2007-01-01
Wastewater stabilization ponds generate low cost by-products that are useful for agriculture. The utilization of these by-products for soil amendment and as a source of nutrients for plants requires a high level of sanitation and stabilization of the organic matter, to maintain acceptable levels of soil, water and air quality. In this study, two aquaculture wastewater treatment systems; recirculating system and a floating plant bed system were designed to improve the quality of irrigation water in local communities with low income. In both systems the grass species Lolium perenne Lam was used as a plant biofilter while vegetable specie Amaranthus viridis was used to evaluate the performance of the system and the suitability of the phyto-treated water for irrigation. It was found that the harmful material removal rate for recirculating system was 88.9% for TAN (total ammonia nitrogen), 90% for NO2(-)-N, 64.8% for NO3(-)-N while for floating plant bed system 82.7% for TAN, 82% for NO2(-)-N and 60.5% for NO3(-)-N. Comparative analysis of the efficiency of waste element removal between the two systems revealed that both systems performed well, however, plant growth was not robust for floating plant bed system while recirculating system is energy consuming. Although both systems did not attain sufficient levels of TN (total nitrogen) and TP (total phosphorus) load reduction, the treatment with L. perenne remarkably improved the irrigation water quality. A. viridis plants irrigated with the phyto-treated discharge water had lesser concentrations of heavy metals in their tissues compared to those irrigated with untreated discharge. The control plants irrigated with untreated discharge were also found to be highly lignified with few stems and small leaves.
Device for generation of pulsed corona discharge
Gutsol, Alexander F [San Ramon, CA; Fridman, Alexander [Marlton, NJ; Blank, Kenneth [Philadelphia, PA; Korobtsev, Sergey [Moscow, RU; Shiryaevsky, Valery [Moscow, RU; Medvedev, Dmitry [Moscow, RU
2012-05-08
The invention is a method and system for the generation of high voltage, pulsed, periodic corona discharges capable of being used in the presence of conductive liquid droplets. The method and system can be used, for example, in different devices for cleaning of gaseous or liquid media using pulsed corona discharge. Specially designed electrodes and an inductor increase the efficiency of the system, permit the plasma chemical oxidation of detrimental impurities, and increase the range of stable discharge operations in the presence of droplets of water or other conductive liquids in the discharge chamber.
NASA Technical Reports Server (NTRS)
Palmer, A. J.; Hess, L. D.; Stephens, R. R.
1976-01-01
A theoretical and experimental investigation into the possibility of achieving CW discharge pumped excimer laser oscillation is reported. Detailed theoretical modeling of capillary discharge pumping of the XeF and KXe and K2 excimer systems was carried out which predicted the required discharge parameters for reaching laser threshold on these systems. Capillary discharge pumping of the XeF excimer system was investigated experimentally. The experiments revealed a lower excimer level population density than predicted theoretically by about an order of magnitude. The experiments also revealed a fluorine consumption problem in the discharge in agreement with theory.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... Remediation Facility Discharges in the Commonwealth of Massachusetts (Including Both Commonwealth and Indian Country Lands) and the State of New Hampshire: The Remediation General Permits (RGP) AGENCY: Environmental... Discharge Elimination System (NPDES) general permits for remediation facility discharges to certain waters...
NASA Technical Reports Server (NTRS)
Berrier, B. L.; Leavitt, L. D.; Bangert, L. S.
1985-01-01
An investigation has been conducted in the Langley 16 Foot Transonic Tunnel to determine the weight flow measurement characteristics of a multiple critical Venturi system and the nozzle discharge coefficient characteristics of a series of convergent calibration nozzles. The effects on model discharge coefficient of nozzle throat area, model choke plate open area, nozzle pressure ratio, jet total temperature, and number and combination of operating Venturis were investigated. Tests were conducted at static conditions (tunnel wind off) at nozzle pressure ratios from 1.3 to 7.0.
Lewelling, B.R.
2004-01-01
Riverine and palustrine wetlands are a major ecological component of river basins in west-central Florida. Healthy wetlands are dependent, in part, upon the frequency and duration of periodic flooding or inundation. This report assesses the extent, area, depth, frequency, and duration of periodic flooding and the effects of potential surface-water withdrawals on wetlands along five river systems in the upper Hillsborough River watershed: Hillsborough and New Rivers, Blackwater and Itchepackesassa Creeks, and East Canal. Results of the study were derived from step-backwater analyses performed for each of the river systems using the U.S. Army Corps of Engineers Hydrologic Engineering Center-River Analysis System (HEC-RAS) one-dimensional model. Step-backwater analyses were performed based on daily mean discharges at the 10th, 50th, 70th, 80th, 90th, 95th, 99.5th, and 99.97th percentiles for selected periods. The step-backwater analyses computed extent of inundation, area of inundation, and hydraulic depth. An assessment of the net reduction of areal inundation for each of the selected percentile discharges was computed if 10 percent of the total river flow were diverted for potential withdrawals. The extent of areal inundation at a cross section is controlled by discharge volume, topography, and the degree to which the channel is incised. Areal inundation can occur in reaches characterized by low topographic relief in the upper Hillsborough watershed during most, if not all, selected discharge percentiles. Most river systems in the watershed, however, have well defined and moderately incised channels that generally confine discharges within the banks at the 90th percentile. The greatest increase in inundated area along the five river systems generally occurred between the 95th to 99.5th percentile discharges. The decrease in inundated area that would result from a potential 10-percent discharge withdrawal at the five river systems ranged as follows: Hillsborough River, 7 to 940 acres (2.0 to 6.0 percent); and New River, 0.2 to 58.9 acres (0 to 11.9 percent); Blackwater Creek, 3.3 to 148 acres (2.2 to 9.4 percent); Itchepackesassa Creek, 1.0 to 104 acres (0.9 to 10.8 percent); and East Canal 0.7 to 34.6 acres (0.5 to 7.6 percent).
Hydrologic data collection activities in the Solomon Gulch basin near Valdez, Alaska
Bigelow, B.B.
1988-01-01
In 1981, the Alaska Power Authority completed construction of a dam spillway at the north end of Solomon Lake near Valdez. Regulation and diversion from the dam since 1982 have significantly altered the natural flow characteristics of Solomon Gulch. In September 1986, the Geological Survey began data collection to determine mean daily discharge at four sites below Solomon Lake and thus document the effects of regulation and diversion of water on the flow at various points in the system. Periodic discharge measurements and continuous records of water stage were obtained at two of the sites, and daily discharge values were computed for all four sites. The report contains descriptions of the data collection sites and the discharge records for each site for September 1986 and water year 1987. (USGS)
An Investigation of Ionic Flows in a Sphere-Plate Electrode Gap
NASA Astrophysics Data System (ADS)
Z. Alisoy, H.; Alagoz, S.; T. Alisoy, G.; B. Alagoz, B.
2013-10-01
This paper presents analyses of ion flow characteristics and ion discharge pulses in a sphere-ground plate electrode system. As a result of variation in electric field intensity in the electrode gap, the ion flows towards electrodes generate non-uniform discharging pulses. Inspection of these pulses provides useful information on ionic stream kinetics, the effective thickness of ion cover around electrodes, and the timing of ion clouds discharge pulse sequences. A finite difference time domain (FDTD) based space-charge motion simulation is used for the numerical analysis of the spatio-temporal development of ionic flows following the first Townsend avalanche, and the simulation results demonstrate expansion of the positive ion flow and compression of the negative ion flow, which results in non-uniform discharge pulse characteristics.
Integrating unmanned aerial systems and LSPIV for rapid, cost-effective stream gauging
NASA Astrophysics Data System (ADS)
Lewis, Quinn W.; Lindroth, Evan M.; Rhoads, Bruce L.
2018-05-01
Quantifying flow in rivers is fundamental to assessments of water supply, water quality, ecological conditions, hydrological responses to storm events, and geomorphological processes. Image-based surface velocity measurements have shown promise in extending the range of discharge conditions that can be measured in the field. The use of Unmanned Aerial Systems (UAS) in image-based measurements of surface velocities has the potential to expand applications of this method. Thus far, few investigations have assessed this potential by evaluating the accuracy and repeatability of discharge measurements using surface velocities obtained from UAS. This study uses large-scale particle image velocimetry (LSPIV) derived from videos captured by cameras on a UAS and a fixed tripod to obtain discharge measurements at ten different stream locations in Illinois, USA. Discharge values are compared to reference values measured by an acoustic Doppler current profiler, a propeller meter, and established stream gauges. The results demonstrate the effects of UAS flight height, camera steadiness and leveling accuracy, video sampling frequency, and LSPIV interrogation area size on surface velocities, and show that the mean difference between fixed and UAS cameras is less than 10%. Differences between LSPIV-derived and reference discharge values are generally less than 20%, not systematically low or high, and not related to site parameters like channel width or depth, indicating that results are relatively insensitive to camera setup and image processing parameters typically required of LSPIV. The results also show that standard velocity indices (between 0.85 and 0.9) recommended for converting surface velocities to depth-averaged velocities yield reasonable discharge estimates, but are best calibrated at specific sites. The study recommends a basic methodology for LSPIV discharge measurements using UAS that is rapid, cost-efficient, and does not require major preparatory work at a measurement location, pre- and post-processing of imagery, or extensive background in image analysis and PIV.
A systematic review of the cost and cost-effectiveness of electronic discharge communications.
Sevick, Laura K; Esmail, Rosmin; Tang, Karen; Lorenzetti, Diane L; Ronksley, Paul; James, Matthew; Santana, Maria; Ghali, William A; Clement, Fiona
2017-07-02
The transition between acute care and community care can be a vulnerable period in a patients' treatment due to the potential for postdischarge adverse events. The vulnerability of this period has been attributed to factors related to the miscommunication between hospital-based and community-based physicians. Electronic discharge communication has been proposed as one solution to bridge this communication gap. Prior to widespread implementation of these tools, the costs and benefits should be considered. To establish the cost and cost-effectiveness of electronic discharge communications compared with traditional discharge systems for individuals who have completed care with one provider and are transitioning care to a new provider. We conducted a systematic review of the published literature, using best practices, to identify economic evaluations/cost analyses of electronic discharge communication tools. Inclusion criteria were: (1) economic analysis and (2) electronic discharge communication tool as the intervention. Quality of each article was assessed, and data were summarised using a component-based analysis. One thousand unique abstracts were identified, and 57 full-text articles were assessed for eligibility. Four studies met final inclusion criteria. These studies varied in their primary objectives, methodology, costs reported and outcomes. All of the studies were of low to good quality. Three of the studies reported a cost-effectiveness measure ranging from an incremental daily cost of decreasing average discharge note completion by 1 day of $0.331 (2003 Canadian), a cost per page per discharge letter of €9.51 and a dynamic net present value of €31.1 million for a 5-year implementation of the intervention. None of the identified studies considered clinically meaningful patient or quality outcomes. Economic analyses of electronic discharge communications are scarcely reported, and with inconsistent methodology and outcomes. Further studies are needed to understand the cost-effectiveness and value for patient care. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
LOUISIANA ENVIRONMENTAL MODELING SYSTEM FOR HYPOXIA RELATED ISSUES
An environmental assessment tool to evaluate the impacts of nonpoint source (NPS) pollutants discharged from Mississippi River basins into the Gulf of Mexico and to assess their effects on receiving water quality will be described. This system (Louisiana Environmental Modeling S...
NASA Astrophysics Data System (ADS)
Lin, Chunjing; Xu, Sichuan; Chang, Guofeng; Liu, Jinling
2015-02-01
A passive thermal management system (TMS) for LiFePO4 battery modules using phase change material (PCM) as the heat dissipation source to control battery temperature rise is developed. Expanded graphite matrix and graphite sheets are applied to compensate low thermal conductivity of PCM and improve temperature uniformity of the batteries. Constant current discharge and mixed charge-discharge duties were applied on battery modules with and without PCM on a battery thermal characteristics test platform. Experimental results show that PCM cooling significantly reduces the battery temperature rise during short-time intense use. It is also found that temperature uniformity across the module deteriorates with the increasing of both discharge time and current rates. The maximum temperature differences at the end of 1C and 2C-rate discharges are both less than 5 °C, indicating a good performance in battery thermal uniformity of the passive TMS. Experiments on warm-keeping performance show that the passive TMS can effectively keep the battery within its optimum operating temperature for a long time during cold weather uses. A three dimensional numerical model of the battery pack with the passive TMS was conducted using ANSYS Fluent. Temperature profiles with respect to discharging time reveal that simulation shows good agreement with experiment at 1C-discharge rate.
O'Connor, N; Milosavljević, V; Daniels, S
2011-08-01
In this paper we present the development and application of a real time atmospheric pressure discharge monitoring diagnostic. The software based diagnostic is designed to extract latent electrical and optical information associated with the operation of an atmospheric pressure dielectric barrier discharge (APDBD) over long time scales. Given that little is known about long term temporal effects in such discharges, the diagnostic methodology is applied to the monitoring of an APDBD in helium and helium with both 0.1% nitrogen and 0.1% oxygen gas admixtures over periods of tens of minutes. Given the large datasets associated with the experiments, it is shown that this process is much expedited through the novel application of multivariate correlations between the electrical and optical parameters of the corresponding chemistries which, in turn, facilitates comparisons between each individual chemistry also. The results of these studies show that the electrical and optical parameters of the discharge in helium and upon the addition of gas admixtures evolve over time scales far longer than the gas residence time and have been compared to current modelling works. It is envisaged that the diagnostic together with the application of multivariate correlations will be applied to rapid system identification and prototyping in both experimental and industrial APDBD systems in the future.
Performance Measurements and Mapping of a R-407C Vapor Injection Scroll Compressor
NASA Astrophysics Data System (ADS)
Lumpkin, Domenique; Spielbauer, Niklas; Groll, Eckhard
2017-08-01
Environmental conditions significantly define the performance of HVAC&R systems. Vapor compression systems in hot climates tend to operate at higher pressure ratios, leading to increased discharge temperatures. Higher discharge temperatures can lead to higher irreversibilities in the compression process, lower specific enthalpies differences across the evaporator, and possibly a reduction in the compressor life due to the breakdown of the oil used for lubrication. To counter these effects, the use of economized, vapor injection compressors is proposed for vapor compression systems in high temperature climates. Such compressors are commercially available for refrigeration applications, in particular, supermarket refrigeration systems. However, compressor maps for vapor injection compressors are limited and none exist for R-407C. Through calorimeter testing, a compressor map for a single-port vapor injection compressor using R-407C was developed. A standard correlation for mapping single-port vapor injection compressors is proposed and validated using the compressor test results. The system and compressor performance with and without vapor injection was considered. As expected, with vapor injection there was a reduction in compressor discharge temperatures and an increase in the system coefficient of performance. The proposed dimensionless correlation is more accurate than the AHRI polynomial for mapping the injection ratio, discharge temperature, and compressor heat loss. The predicted volumetric efficiency values from the dimensionless correlation is within 1% of the measured valued. Similarly, the predicted isentropic efficiency values are within 2% of the measured values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Yenan; Dong, Lifang, E-mail: donglfhbu@163.com; Zhao, Longhu
2014-10-15
The interaction between micro-discharges involved in surface discharges (SDs) is studied in dielectric barrier discharge system. Instantaneous images taken by high speed cameras show that the SDs are induced by volume discharges (VDs). They cannot cross the midperpendicular of two neighbouring volume charges at low voltage while they stretch along it at high voltage, indicating that there is interaction between SDs. The differences of plasma parameters between SD and VD are studied by optical emission spectroscopy. The simulation of the electric fields of the wall charges accumulated by VD further confirms the existence of the interaction.
NASA Astrophysics Data System (ADS)
Mao, Xumei; Wang, Hua; Feng, Liang
2018-05-01
In a groundwater flow system, the age of groundwater should gradually increase from the recharge zone to the discharge zone within the same streamline. However, it is occasionally observed that the groundwater age becomes younger in the discharge zone in the piedmont alluvial plain, and the oldest age often appears in the middle of the plain. A new set of groundwater chemistry and isotopes was employed to reassess the groundwater 14C ages from the discharge zone in the North China Plain (NCP). Carbonate precipitation, organic matter oxidation and cross-flow mixing in the groundwater from the recharge zone to the discharge zone are recognized according to the corresponding changes of HCO3- (or DIC) and δ13C in the same streamline of the third aquifer of the NCP. The effects of carbonate precipitation and organic matter oxidation are calibrated with a 13C mixing model and DIC correction, but these corrected 14C ages seem unreasonable because they grow younger from the middle plain to the discharge zone in the NCP. The relationship of Cl- content and the recharge distance is used to estimate the expected Cl- content in the discharge zone, and ln(a14C)/Cl is proposed to correct the a14C in groundwater for the effect of cross-flow mixing. The 14C ages were reassessed with the corrected a14C due to the cross-flow mixing varying from 1.25 to 30.58 ka, and the groundwater becomes older gradually from the recharge zone to the discharge zone. The results suggest that the reassessed 14C ages are more reasonable for the groundwater from the discharge zone due to cross-flow mixing.
Plasma Discharge Process in a Pulsed Diaphragm Discharge System
NASA Astrophysics Data System (ADS)
Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu
2014-12-01
As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Yim, John; Herman, Daniel; Williams, George; Gilland, James; Peterson, Peter; Hofer, Richard; Mikellides, Ioannis
2016-01-01
NASAs Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) Hall thruster has been the subject of extensive technology maturation in preparation for flight system development. Part of the technology maturation effort included experimental evaluation of the TDU-1 thruster with conducting and dielectric front pole cover materials in two different electrical configurations. A graphite front pole cover thruster configuration with the thruster body electrically tied to cathode and an alumina front pole cover thruster configuration with the thruster body floating were evaluated. Both configurations were also evaluated at different facility background pressure conditions to evaluate background pressure effects on thruster operation. Performance characterization tests found that higher thruster performance was attained with the graphite front pole cover configuration with the thruster electrically tied to cathode. A total thrust efficiency of 68 and a total specific impulse of 2,820 s was demonstrated at a discharge voltage of 600 V and a discharge power of 12.5 kW. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations and with maps of the current-voltage-magnetic field (IVB). Analysis of TDU-1 discharge current waveforms found that lower normalized discharge current peak-to-peak and root mean square magnitudes were attained when the thruster was electrically floated with alumina front pole covers. Background pressure effects characterization tests indicated that the thruster performance and stability was mostly invariant to changes in the facility background pressure for vacuum chamber pressure below 110-5 Torr-Xe (for thruster flow rate above 8 mgs). Power spectral density analysis of the discharge current waveform showed that increasing the vacuum chamber background pressure resulted in a higher discharge current dominant frequency. Finally the IVB maps of the TDU-1 thruster taken at elevated magnetic fields indicated that the discharge current became more oscillatory with increased facility background pressure at lower thruster mass flow rates, where thruster operation at higher flow rates resulted in less change to the thrusters IVB characteristics.
Studies of corona and back discharges in carbon dioxide
NASA Astrophysics Data System (ADS)
Czech, Tadeusz; Sobczyk, Arkadiusz Tomasz; Jaworek, Anatol; Krupa, Andrzej; Rajch, Eryk
2013-01-01
Results of spectroscopic investigations and current-voltage characteristics of corona and back discharges generated in point-plane electrode geometry in CO2 at atmospheric pressure for positive and negative polarity of the discharge electrode are presented in the paper. Three forms of back discharge, for both polarities, were investigated: glow, streamer and low-current back-arc. To generate the back-discharges for the conditions similar to electrostatic precipitator, the plate electrode was covered with fly ash layer. In order to characterize back discharge processes, the emission spectra were measured and compared with those obtained for normal discharge, generated in the same electrode configuration but without the fly ash layer on the plate electrode. The measurements have shown that optical emission spectral lines of atoms and molecules, excited or ionised in back discharge, depend on the forms of the discharge, the discharge current, and are different in the zones close to needle electrode and fly ash layer. From the comparison of spectral lines of back and normal discharges, an effect of fly ash layer on discharge characteristics and morphology has been determined. In normal corona, the emission spectra are mainly predetermined by the working gas components, but in the case of back discharge, the atomic and molecular lines, resulting from chemical composition of fly ash, are also identified. Differences in the spectra of back discharge for positive and negative polarities of the needle electrode have been explained by considering the kind of ions generated in the crater in fly ash layer. For back arc, the emission of spectral lines of atoms and molecules from fly ash layer can be recorded in the crater zone, but in the needle zone, only the emission lines of CO2 and its decomposition products (CO and C2) can be noticed. The studies of back discharge in CO2, as one of the main components of flue gases, were undertaken because this type of discharge, after unwanted inception, decreases the energy and collection efficiencies of electrostatic precipitator. The second reason behind these studies is that CO2 is the main component of flue gas leaving oxyfuel boiler that re-circulates in the combustion-precipitation cycle. It was shown that discharges in CO2 lead to contamination of discharge electrode with carbonaceous products that can cause severe maintenance problems of electrostatic precipitator. The recognition of the characteristics of electrostatic precipitator operating in the oxyfuel system is, therefore, of crucial importance for exhaust gas cleaning in modern combustion systems.
Book, Katrin; Dinkel, Andreas; Henrich, Gerhard; Stuhr, Claudia; Peuker, Mareike; Härtl, Kristin; Brähler, Elmar; Herschbach, Peter
2013-12-01
The objective of this study is to determine whether the inclusion of a 'psychooncological statement' (PO-statement) in the discharge summary enhances patient-physician communication about psychosocial issues across the inpatient and outpatient sector. A total of 1416 cancer patients were randomly assigned to the intervention (with PO-statement in the discharge summary) or control group (discharge summary without PO-statement). Shortly before discharge from the hospital (T1), patients from the intervention group were screened for psychosocial distress. Based on the electronic clinical documentation system, screening results were subsequently integrated into the discharge summary, which automatically generated a PO-statement. To determine the effect of the PO-statement, patients as well as their primary care physicians (n = 596) were asked during follow-up care (T2) whether psychosocial distress was discussed during the last consultation. Including a PO-statement in the discharge summary did not result in more frequent discussions about psychosocial issues compared with the control group from the patients' and physicians' perspectives. Instead, discussions about psychosocial well-being were significantly associated with women of the patient (p = <0.001) and the physician (p = 0.011), medical discipline (gynecologists; p = 0.002), cancer diagnosis (gynecological cancer; p = 0.002), metastases (p = <0.001), professional training of patients (none, p = 0.026), and psychosocial qualification of physicians (p = 0.018). Written information on psychosocial distress in the discharge summary alone does not affect communication. Copyright © 2013 John Wiley & Sons, Ltd.
Zhai, Xiaodong; Ding, Yanjun; Peng, Zhimin; Luo, Rui
2012-07-10
Nitric oxide (NO) concentrations were measured using the γ band system spectrum based on the strong self-absorption effect of NO in pulsed corona discharges. The radiative transitional intensities of the NO γ band were simulated based on the theory of molecular spectroscopy. The intensities of some bands, especially γ(0,0) and γ(1,0), are weakened by the self-absorption. The correlations between the spectral self-absorption intensities and NO concentration were validated using a modified Beer-Lambert law with a combined factor K relating the branching ratio and the NO concentration, and a nonlinear index α that is applicable to the broadband system. Optical emissive spectra in pulsed corona discharges in NO and N2/He mixtures were used to evaluate the two parameters for various conditions. Good agreement between the experimental and theoretical results verifies the self-absorption behavior seen in the UV spectra of the NO γ bands.
NASA Astrophysics Data System (ADS)
Baraer, M.; Chesnokova, A.; Huh, K. I.; Laperriere-Robillard, T.
2017-12-01
Saint-Elias Mountains host numerous cryospheric systems such as glaciers, seasonal and perennial snow cover, permafrost, aufeis, and different forms of buried ice. Those systems are very sensitive to climate changes and exhibit ongoing reduction in extent and/or changes in formation/ablation times. Because they highly influence the hydrological regimes of rivers, cryospheric changes raise concerns about consequences for regional water resources and ecosystems. The present study combines historical data analysis and hydrological modeling in order to estimate how cryospheric changes impact hydrological regimes at eight watersheds of different glacier cover (0- 30%) in the southwest Yukon. Methods combine traditional hydrograph analysis techniques and more advance techniques such as Fast Fourier Transform filters used to isolate significant trends in discharge properties from noise or climatic oscillations. Measured trends in discharge variables are connected to cryospheric changes by using a water balance / peak water model (Baraer et al., 2012), here adapted to the main cryospheric systems that characterize the southwest Yukon.Results show three distinct hydrological regimes for (1) non glacierized, (2) glacierized, and (3) major lakes hosting catchments. The studied glacierized catchments have not passed the "peak water" yet and still exhibit increases in yearly and late summer discharges and a decrease in runoff variability. All watersheds show an increase in winter discharge and a snowmelt-driven shift of yearly peak discharge toward earlier in the season. The study suggests that, in a couple of decades, water resources and dependent ecosystems will face the combined effects of (A) a shift in the contribution trend from declining perennial cryospheric systems and (B) continuing alteration of the contribution from the seasonal cryospheric systems.
[Wearable Automatic External Defibrillators].
Luo, Huajie; Luo, Zhangyuan; Jin, Xun; Zhang, Leilei; Wang, Changjin; Zhang, Wenzan; Tu, Quan
2015-11-01
Defibrillation is the most effective method of treating ventricular fibrillation(VF), this paper introduces wearable automatic external defibrillators based on embedded system which includes EGG measurements, bioelectrical impedance measurement, discharge defibrillation module, which can automatic identify VF signal, biphasic exponential waveform defibrillation discharge. After verified by animal tests, the device can realize EGG acquisition and automatic identification. After identifying the ventricular fibrillation signal, it can automatic defibrillate to abort ventricular fibrillation and to realize the cardiac electrical cardioversion.
Masterson, John P.; Carlson, Carl S.; Walter, Donald A.; Other contributing authors: Bent, Gardner C.; Massey, Andrew J.
2009-01-01
The glacial sediments that underlie the Plymouth-Carver-Kingston-Duxbury area of southeastern Massachusetts compose an important aquifer system that is the primary source of water for a region undergoing rapid development. Population increases and land-use changes in this area has led to two primary environmental effects that relate directly to groundwater resources: (1) increases in pumping that can adversely affect environmentally sensitive groundwater-fed surface waters, such as ponds, streams, and wetlands; and (2) adverse effects of land use on the quality of water in the aquifer. In response to these concerns, the U.S. Geological Survey, in cooperation with the Massachusetts Department of Environmental Protection, began an investigation in 2005 to improve the understanding of the hydrogeology in the area and to assess the effects of changing pumping and recharge conditions on groundwater flow in the Plymouth-Carver-Kingston-Duxbury aquifer system. A numerical flow model was developed based on the USGS computer program MODFLOW-2000 to assist in the analysis of groundwater flow. Model simulations were used to determine water budgets, flow directions, and the sources of water to pumping wells, ponds, streams, and coastal areas. Model-calculated water budgets indicate that approximately 298 million gallons per day (Mgal/d) of water recharges the Plymouth-Carver-Kingston-Duxbury aquifer system. Most of this water (about 70 percent) moves through the aquifer, discharges to streams, and then reaches the coast as surface-water discharge. Of the remaining 30 percent of flow, about 25 percent of the water that enters the aquifer as recharge discharges directly to coastal areas and 5 percent discharges to pumping wells. Groundwater withdrawals are anticipated to increase from the current (2005) rate of about 14 Mgal/d to about 21 Mgal/d by 2030. Pumping from large-capacity production wells decreases water levels and increases the potential for effects on surface-water bodies, which are affected by pumping and wastewater disposal locations and rates. Pumping wells that are upgradient of surface-water bodies potentially capture water that would otherwise discharge to these surface-water bodies, thereby reducing streamflow and pond levels. The areas most affected by proposed increases in groundwater withdrawals are in the Towns of Plymouth and Wareham where more than half of the proposed increase in pumping will occur. In response to an increase of about 7 Mgal/d of pumping, groundwater discharge to streams is reduced by about 6 cubic feet per second (ft3/s) (about 4 Mgal/d) from a total of about 325 ft3/s. Reduction in streamflow is moderated by an increase of artificial recharge from wastewater returned to the aquifer by onsite domestic septic systems and centralized wastewater treatment facilities. It is anticipated that about 3 Mgal/d of the 7 Mgal/d of increase in pumped water will be returned to the aquifer as wastewater by 2030. Currently (2005) about 3 percent of groundwater discharge to streams is from wastewater return flow to the aquifer during average conditions. During drought conditions, the component of streamflow augmented by wastewater return flow doubles as wastewater recharge remains constant and aquifer recharge rates decrease. Wastewater return flow, whether as direct groundwater discharge to streams or as an additional source of aquifer recharge, increases the height of the water table near streams, thereby moderating the effects of increased groundwater withdrawals on streamflow. An analysis of a simulated drought similar to the 1960s drought of record indicates that the presence of streams moderates the effects on water levels of reduced aquifer recharge. The area where water-table altitudes were least affected by drought was in the Weweantic River watershed in the Town of Carver. Water levels decreased by less than 2 feet from current average conditions compared to decreases of greater than 5
Effects of suburban development on runoff generation in the Croton River basin, New York, USA
Burns, D.; Vitvar, T.; McDonnell, J.; Hassett, J.; Duncan, J.; Kendall, C.
2005-01-01
The effects of impervious area, septic leach-field effluent, and a riparian wetland on runoff generation were studied in three small (0.38-0.56 km 2) headwater catchments that represent a range of suburban development (high density residential, medium density residential, and undeveloped) within the Croton River basin, 70 km north of New York City. Precipitation, stream discharge, and groundwater levels were monitored at 10-30 min intervals for 1 year, and stream water and groundwater samples were collected biweekly for ??18O, NO3-, and SO42- analysis for more than 2 years during an overlapping period in 2000-2002. Data from 27 storms confirmed that peak magnitudes increased and recession time decreased with increasing development, but lags in peak arrival and peak discharge/mean discharge were greatest in the medium density residential catchment, which contains a wetland in which storm runoff is retained before entering the stream. Baseflow during a dry period from Aug. 2001-Feb. 2002 was greatest in the high-density residential catchment, presumably from the discharge of septic effluent through the shallow groundwater system and into the stream. In contrast, moderate flows during a wet period from Mar.-Aug. 2002 were greatest in the undeveloped catchment, possibly as a result of greater subsurface storage or greater hydraulic conductivity at this site. The mean residence time of baseflow was about 30 weeks at all three catchments, indicating that human influence was insufficient to greatly affect the groundwater recharge and discharge properties that determine catchment residence time. These results suggest that while suburban development and its associated impervious surfaces and storm drains accelerate the transport of storm runoff into streams, the combined effects of remnant natural landscape features such as wetlands and human alterations such as deep groundwater supply and septic systems can change the expected effects of human development on storm runoff and groundwater recharge. ?? 2005 Elsevier B.V. All rights reserved.
Increasing Flood Risk due to Run-off Outflow near Estuarine City during Storm Event
NASA Astrophysics Data System (ADS)
Son, S.; Lee, C.; Do, K.; Jung, T.
2017-12-01
Tropical cyclone easily causes inundation damage to low-lying coastal area and the damage may be amplified due to tide motion, sea-level rise, riverine discharges. Specifically, typhoons are accompanied by intensive rainfall, which will of course raise the river water level and thus enhance the flooding damages. If the tidal cycle coincides the high water, flooding will be even aggravated. In the present study, we simulated storm surge motions at the coastal area considering combined effects of tidal and river discharge with aim to improve the accuracy of flooding prediction. The quasi 3-dimension ocean circulation model, Delf3D was used which solves the unsteady shallow water equation in the 2D and 3D. Since Delft3D is much applicable to accommodate the indirect flooding factors such as riverine discharge and short waves, outer-coupled modeling system was established to account for combined tide-surge-riverine discharge effects. In such integrated system, 11 tidal constituents were input as open boundary condition using TPXO 7.2 model, while the water level per unit time was preliminary calculated by HEC-HMS model and input as the upstream boundary conditions for river inside the domain. Typhoon MAEMI which attacked Masan city located at southern coast of South Korea and caused severe inundation damages in 2003 was selected for the study event. Basic information for typhoon such as path, wind speed, atmospheric pressure every 3 hours was provided by the Korea Meteorological Agency and was adopted. The simulation was implemented with tide and storm surge boundary conditions focusing on the target area, Masan, while the additional consideration on the discharge of the river inside the domain was also made. Simulated water level at the fixed location was compared to the observation for its verification and the extent of inundation areas of Masan were compared between observed and calculated. The marginal contribution of riverine discharge on the flooding area(or depth) was assessed by comparing tide-surge with tide-surge-riverine discharge simulations. Finally, the importance of the specific consideration on the riverine discharge during storm surge modeling can be addressed.
Hydrogeological controls on spatial patterns of groundwater discharge in peatlands
NASA Astrophysics Data System (ADS)
Hare, Danielle K.; Boutt, David F.; Clement, William P.; Hatch, Christine E.; Davenport, Glorianna; Hackman, Alex
2017-11-01
Peatland environments provide important ecosystem services including water and carbon storage, nutrient processing and retention, and wildlife habitat. However, these systems and the services they provide have been degraded through historical anthropogenic agricultural conversion and dewatering practices. Effective wetland restoration requires incorporating site hydrology and understanding groundwater discharge spatial patterns. Groundwater discharge maintains wetland ecosystems by providing relatively stable hydrologic conditions, nutrient inputs, and thermal buffering important for ecological structure and function; however, a comprehensive site-specific evaluation is rarely feasible for such resource-constrained projects. An improved process-based understanding of groundwater discharge in peatlands may help guide ecological restoration design without the need for invasive methodologies and detailed site-specific investigation. Here we examine a kettle-hole peatland in southeast Massachusetts historically modified for commercial cranberry farming. During the time of our investigation, a large process-based ecological restoration project was in the assessment and design phases. To gain insight into the drivers of site hydrology, we evaluated the spatial patterning of groundwater discharge and the subsurface structure of the peatland complex using heat-tracing methods and ground-penetrating radar. Our results illustrate that two groundwater discharge processes contribute to the peatland hydrologic system: diffuse lower-flux marginal matrix seepage and discrete higher-flux preferential-flow-path seepage. Both types of groundwater discharge develop through interactions with subsurface peatland basin structure, often where the basin slope is at a high angle to the regional groundwater gradient. These field observations indicate strong correlation between subsurface structures and surficial groundwater discharge. Understanding these general patterns may allow resource managers to more efficiently predict and locate groundwater seepage, confirm these using remote sensing technologies, and incorporate this information into restoration design for these critical ecosystems.
NASA Astrophysics Data System (ADS)
Wang, Yujie; Zhang, Xu; Liu, Chang; Pan, Rui; Chen, Zonghai
2018-06-01
The power capability and maximum charge and discharge energy are key indicators for energy management systems, which can help the energy storage devices work in a suitable area and prevent them from over-charging and over-discharging. In this work, a model based power and energy assessment approach is proposed for the lithium-ion battery and supercapacitor hybrid system. The model framework of the lithium-ion battery and supercapacitor hybrid system is developed based on the equivalent circuit model, and the model parameters are identified by regression method. Explicit analyses of the power capability and maximum charge and discharge energy prediction with multiple constraints are elaborated. Subsequently, the extended Kalman filter is employed for on-board power capability and maximum charge and discharge energy prediction to overcome estimation error caused by system disturbance and sensor noise. The charge and discharge power capability, and the maximum charge and discharge energy are quantitatively assessed under both the dynamic stress test and the urban dynamometer driving schedule. The maximum charge and discharge energy prediction of the lithium-ion battery and supercapacitor hybrid system with different time scales are explored and discussed.
RELATIVE POTENCIES FOR ACUTE EFFECTS OF PYRETHROIDS ON MOTOR FUNCTION IN RATS.
A proposed common mode-of-action for pyrethroid insecticides, includes alterations in sodium channel dynamics in nervous system tissues, consequent disturbance of neuronal membrane polarization, abnormal discharge in targeted neurons, and changes in nervous system function. The p...
NPDES Permit for Denver Federal Center Municipal Separate Storm Sewer System in Colorado
Denver Federal Center Municipal Separate Storm Sewer System is authorized to discharge from all municipal separate storm sewer outfalls existing as of the effective date of permit CO-R042004 to receiving waters Lakewood, Jefferson County, Colorado.
Hubbard, Laura E.; Keefe, Steffanie H.; Kolpin, Dana W.; Barber, Larry B.; Duris, Joseph W.; Hutchinson, Kasey J.; Bradley, Paul M.
2016-01-01
Effluent-impacted surface water has the potential to transport not only water, but wastewater-derived contaminants to shallow groundwater systems. To better understand the effects of effluent discharge on in-stream and near-stream hydrologic conditions in wastewater-impacted systems, water-level changes were monitored in hyporheic-zone and shallow-groundwater piezometers in a reach of Fourmile Creek adjacent to and downstream of the Ankeny (Iowa, USA) wastewater treatment plant (WWTP). Water-level changes were monitored from approximately 1.5 months before to 0.5 months after WWTP closure. Diurnal patterns in WWTP discharge were closely mirrored in stream and shallow-groundwater levels immediately upstream and up to 3 km downstream of the outfall, indicating that such discharge was the primary control on water levels before shutdown. The hydrologic response to WWTP shutdown was immediately observed throughout the study reach, verifying the far-reaching hydraulic connectivity and associated contaminant transport risk. The movement of WWTP effluent into alluvial aquifers has implications for potential WWTP-derived contamination of shallow groundwater far removed from the WWTP outfall.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Pipe sizes and discharge rates for enclosed ventilation... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. (a) The minimum pipe size for the initial...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. 108.437 Section 108.437 Shipping COAST GUARD, DEPARTMENT OF... Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.437 Pipe sizes and discharge rates for...
Design of a fast computer-based partial discharge diagnostic system
NASA Technical Reports Server (NTRS)
Oliva, Jose R.; Karady, G. G.; Domitz, Stan
1991-01-01
Partial discharges cause progressive deterioration of insulating materials working in high voltage conditions and may lead ultimately to insulator failure. Experimental findings indicate that deterioration increases with the number of discharges and is consequently proportional to the magnitude and frequency of the applied voltage. In order to obtain a better understanding of the mechanisms of deterioration produced by partial discharges, instrumentation capable of individual pulse resolution is required. A new computer-based partial discharge detection system was designed and constructed to conduct long duration tests on sample capacitors. This system is capable of recording large number of pulses without dead time and producing valuable information related to amplitude, polarity, and charge content of the discharges. The operation of the system is automatic and no human supervision is required during the testing stage. Ceramic capacitors were tested at high voltage in long duration tests. The obtained results indicated that the charge content of partial discharges shift towards high levels of charge as the level of deterioration in the capacitor increases.
Analysis of the internal temperature of the cells in a battery pack during SOC balancing
NASA Astrophysics Data System (ADS)
Mizanur, R.; Rashid, M. M.; Rahman, A.; Zahirul Alam, A. H. M.; Ihsan, S.; Mollik, M. S.
2017-03-01
Lithium-ion batteries are more suitable for the application of electric vehicle due to high energy and power density compared to other rechargeable batteries. However, the battery pack temperature has a great impact on the overall performance, cycle life, normal charging-discharging behaviour and even safety. During rapid charge transferring process, the internal temperature may exceed its allowable limit (460C). In this paper, an analysis of internal temperature during charge balancing and discharging conditions is presented. Specific interest is paid to the effects of temperature on the different rate of ambient temperature and discharging current. Matlab/Simulink Li-ion battery model and quasi-resonant converter base balancing system are used to study the temperature effect. Rising internal temperature depends on the rate of balancing current and ambient temperature found in the simulation results.
Effects of Lightning in the Upper Atmosphere
NASA Astrophysics Data System (ADS)
Sentman, Davis D.; Pasko, Victor P.; Morrill, Jeff S.
2010-02-01
AGU Chapman Conference on Effects of Thunderstorms and Lightning in the Upper Atmosphere; University Park, Pennsylvania, 10-14 May 2009; The serendipitous observation in 1989 of electrical discharge in the high atmosphere induced by thundercloud lightning launched a new field of geophysical investigation. From this single unexpected observation sprang a vigorous and fertile new research field that simultaneously encompasses geophysical disciplines that are normally pursued independently, such as meteorology and lightning, plasma and gas discharge physics, atmospheric chemistry, ionospheric physics, and energetic particle physics. Transient electrical discharge in the upper atmosphere spans the full range of altitudes between the tropopause and the ionosphere and takes a variety of forms that carry the whimsical names red sprites, blue jets, gigantic jets, elves (emissions of light and very low frequency perturbations from electromagnetic pulse sources), and sprite halos, collectively known as transient luminous events (TLEs). To date, TLEs have been observed from ground and airborne or spaceborne platforms above thunderstorm systems worldwide, and radio observations made concomitantly with optical observations have shown that they are produced by the transient far fields of thundercloud lightning. TLEs appear to be large-scale (tens of kilometers in dimension), upper atmospheric versions of conventional gas discharge akin to weakly ionized, collision-dominated systems found in laboratory discharge devices (millimeter-centimeter dimensions), with characteristic energies of a few electron volts. The dominant physical processes have been identified as described by the familiar kinetic theory of the photochemistry of the upper atmosphere, but with electric field-driven electron impact ionization playing the role of photolysis or energetic precipitating particle-induced ionization.
The effect of temperature on pulsed positive streamer discharges in air over the range 292 K–1438 K
NASA Astrophysics Data System (ADS)
Ono, Ryo; Ishikawa, Yuta
2018-05-01
The effect of temperature on pulsed positive streamer discharges in air is measured by comparing atmospheric-pressure, high-temperature discharges with low-pressure, room-temperature discharges at the same air densities n and discharge voltages. Both discharges have the same reduced electric field E/n, so the differences between the two discharges only depend on the temperature, which is varied from 292 K to 1438 K. Temperature affects the discharge pulse energy most significantly; at 1438 K, the energy of an atmospheric-pressure discharge pulse is approximately 30 times larger than that of the corresponding 20.5 kPa, room-temperature discharge. Temperature also affects the shapes of the streamers when K, but no significant effect is observed for K. There is also no significant temperature effect on the spatially integrated intensity of N2(C–B) emission. However, temperature strongly affects the ratio of the integrated emission intensity to the discharge energy. No effect of the temperature is observed on the propagation velocity of the primary streamer or on the length of the secondary streamer.
NASA Astrophysics Data System (ADS)
Du, Chang Ming; Wang, Jing; Zhang, Lu; Xia Li, Hong; Liu, Hui; Xiong, Ya
2012-01-01
Gliding arc discharge has been investigated in recent years as an innovative physicochemical technique for contaminated water treatment at atmospheric pressure and ambient temperature. In this study we tested a gas-liquid gliding arc discharge reactor, the bacterial suspension of which was treated circularly. When the bacterial suspension was passed through the electrodes and circulated at defined flow rates, almost 100% of the bacteria were killed in less than 3.0 min. Experimental results showed that it is possible to achieve an abatement of 7.0 decimal logarithm units within only 30 s. Circulation flow rates and types of feeding gas caused a certain impact on bacteria inactivation, but the influences are not obvious. So, under the promise of sterilization effect, industrial applications can select their appropriate operating conditions. All inactivation curves presented the same three-phase profile showing an apparent sterilization effect. Analysis of the scanning electron microscope images of bacterial cells supports the speculation that the gas-liquid gliding arc discharge plasma is acting under various mechanisms driven essentially by oxidation and the effect of electric field. These results enhance the possibility of applying gas-liquid gliding arc discharge decontamination systems to disinfect bacterial-contaminated water. Furthermore, correlational research indicates the potential applications of this technology in rapid sterilization of medical devices, spacecraft and food.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-24
... Pollutant Discharge Elimination System (AgPDES) program pursuant to Section 402(b) of the Clean Water Act... Discharge Elimination System (NPDES) permit program under Section 402(n)(3) of the Act for all discharges of... through Friday, excluding legal holidays, at EPA Region 6, 1445 Ross Ave., Dallas, Texas 75202. A copy of...
CO2 conversion in non-thermal plasma and plasma/g-C3N4 catalyst hybrid processes
NASA Astrophysics Data System (ADS)
Lu, Na; Sun, Danfeng; Zhang, Chuke; Jiang, Nan; Shang, Kefeng; Bao, Xiaoding; Li, Jie; Wu, Yan
2018-03-01
Carbon dioxide conversion at atmosphere pressure and low temperature has been studied in a cylindrical dielectric barrier discharge (DBD) reactor. Pure CO2 feed flows to the discharge zone and typical filamentary discharges were obtained in each half-cycle of the applied voltage. The gas temperature increased with discharge time and discharge power, which was found to affect the CO2 decomposition deeply. As the DBD reactor was cooled to ambient temperature, both the conversion of CO2 and the CO yield were enhanced. Especially the energy efficiencies changed slightly with the increase of discharge power and were much higher in cooling condition comparing to those without cooling. At a discharge power of 40 W, the energy efficiency under cooling condition was approximately six times more than that without cooling. Gas flow rate was observed to affect CO2 conversion and 0.1 L min-1 was obtained as optimum gas flow rate under cooling condition. In addition, the CO2 conversion rate in plasma/g-C3N4 catalyst hybrid system was twice times as that in plasma-alone system. In case of cooling, the existence of g-C3N4 catalyst contributed to a 47% increase of CO2 conversion compared to the sole plasma process. The maximum energy-efficiency with g-C3N4 was 0.26 mmol kJ-1 at 20 W, which increased by 157% compared to that without g-C3N4. The synergistic effect of DBD plasma with g-C3N4 on pure CO2 conversion was verified.
NASA Astrophysics Data System (ADS)
Richardson, M. J.; Zuck, N.; Gardner, W. D.
2016-02-01
Flow from the Mississippi-Atchafalaya River System generally peaks during the spring freshet, discharging nutrient-rich fresh water and sediment into the northern Gulf of Mexico. The peak discharge varies year to year as a result of varying drought or flood conditions in the Mississippi watershed. When compared to an 8-year climatological average, summer 2012 is characterized by low discharge into the northern Gulf of Mexico, whereas summer 2013 is characterized by average discharge conditions. Water samples were collected during four cruises during June and August of 2012 and 2013 to assess the changes in concentration and composition of bulk particulate matter. While no consistent relationship between particulate matter composition and hypoxia was observed, there are several statistically significant seasonal and inter-annual changes in the concentration and composition of particulate matter associated with varying river discharge. There is also evidence that some sub-pycnocline turbidity and chlorophyll-a may be due to in situ primary productivity, rather than settled plankton containing chlorophyll-a.
Corollary discharge provides the sensory content of inner speech.
Scott, Mark
2013-09-01
Inner speech is one of the most common, but least investigated, mental activities humans perform. It is an internal copy of one's external voice and so is similar to a well-established component of motor control: corollary discharge. Corollary discharge is a prediction of the sound of one's voice generated by the motor system. This prediction is normally used to filter self-caused sounds from perception, which segregates them from externally caused sounds and prevents the sensory confusion that would otherwise result. The similarity between inner speech and corollary discharge motivates the theory, tested here, that corollary discharge provides the sensory content of inner speech. The results reported here show that inner speech attenuates the impact of external sounds. This attenuation was measured using a context effect (an influence of contextual speech sounds on the perception of subsequent speech sounds), which weakens in the presence of speech imagery that matches the context sound. Results from a control experiment demonstrated this weakening in external speech as well. Such sensory attenuation is a hallmark of corollary discharge.
Analyzing discharge strategies during acute care: a discrete-event simulation study.
Crawford, Elizabeth A; Parikh, Pratik J; Kong, Nan; Thakar, Charuhas V
2014-02-01
We developed a discrete-event simulation model of patient pathway through an acute care hospital that comprises an ED and several inpatient units. The effects of discharge timing on ED waiting and boarding times, ambulance diversions, leave without treatment, and readmissions were explicitly modeled. We then analyzed the impact of 1 static and 2 proactive discharge strategies on these system outcomes. Our analysis indicated that although the 2 proactive discharge strategies significantly reduced ED waiting and boarding times, and several other measures, compared with the static strategy (P < 0.01), the number of readmissions increased substantially. Further analysis indicated that these findings are sensitive to changes in patient arrival rate and conditions for ambulance diversion. Determining the appropriate time to discharge patients not only can affect individual patients' health outcomes, but also can affect various aspects of the hospital. The study improves our understanding of how individual inpatient discharge decisions can be objectively viewed in terms of their impact on other operations, such as ED crowding and readmission, in an acute care hospital.
NASA Astrophysics Data System (ADS)
David, Matej; Gollasch, Stephan; Penko, Ludvik
2018-03-01
Information about the profile of ballast water discharges in a port is one of the basic elements of the decision making process in ballast water risk assessment and management, and supports the evaluation of dimensions and processes of aquatic species invasions with vessels ballast water. In the lack of ballast water reporting, ballast water discharge assessments need to be conducted. In this study we have assessed and compared ballast water discharge profiles of two ports with different maritime traffic and cargo profiles, the Port of Hamburg (Germany) and the Muuga Harbour, Port of Tallinn (Estonia). This study shows methods and approaches which can be used to assess volumes and donor ports of ballast water discharges for a port at the level of each vessel call. These methods and approaches can be applied to any port to support the implementation of feasible and efficient ballast water management measures and to enable environmental studies including long-term accumulation risks of disinfection by-products from ballast water management systems making use of active substances, as well as for discharges of other chemical compounds.
Climate and floods still govern California levee breaks
Florsheim, J.L.; Dettinger, M.D.
2007-01-01
Even in heavily engineered river systems, climate still governs flood variability and thus still drives many levee breaks and geomorphic changes. We assemble a 155-year record of levee breaks for a major California river system to find that breaks occurred in 25% of years during the 20th Century. A relation between levee breaks and river discharge is present that sets a discharge threshold above which most levee breaks occurred. That threshold corresponds to small floods with recurrence intervals of ???2-3 years. Statistical analysis illustrates that levee breaks and peak discharges cycle (broadly) on a 12-15 year time scale, in time with warm-wet storm patterns in California, but more slowly or more quickly than ENSO and PDO climate phenomena, respectively. Notably, these variations and thresholds persist through the 20th Century, suggesting that historical flood-control effects have not reduced the occurrence or frequency of levee breaks. Copyright 2007 by the American Geophysical Union.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, R.K.; Chowdhury, S.
The aim of this paper is to access the influence of water quality both on the occurrence of, and utilization by, elephants (Elephas maximus) in a riverine habitat. Mining operations and other anthropogenic changes to natural river systems have caused degradation of the ecosystem for elephants. A decline in their numbers has been seen throughout the Singhbhum Forests, India due to fragmentation and loss of habitat. The need to preserve and restore the habitat of the elephant is accepted, but until the factors that influence their distribution are known and understood, suitable management plans cannot be implemented. The study areamore » was the catchment of the river Koina where waste discharge from an iron oremine and processing plant impact upon water quality. The study period from April 1995 to March 1996 looked at sections of the river where unregulated mine discharge was made, and where regulation through tailing ponds controlled total suspended solids (TSS) output from the mine waste water to the river system. Various physico-chemical parameters recorded at seven sampling stations were quantified. Principal Component Analysis (PCA) segregated the key parameters in determining the discharge levels of both regulated and unregulated discharge at various sites.« less
Sekimoto, Kanako; Sakakura, Motoshi; Kawamukai, Takatomo; Hike, Hiroshi; Shiota, Teruhisa; Usui, Fumihiko; Bando, Yasuhiko; Takayama, Mitsuo
2016-08-02
Herein it is shown that a combination of direct analysis in real time (DART) with a corona discharge system consisting of only a needle electrode easily improves DART ionization efficiency. Positive and negative DC corona discharges led to a formation of abundant excited helium atoms as well as the reactant ions H3O(+)(H2O)n and O2˙(-) in the DART analyte ionization area. These phenomena resulted in an increase in the absolute intensities of (de)protonated analytes by a factor of 2-20 over conventional DART. The other analyte ions detected in this corona-DART system (i.e., molecular ions, fragment ions, oxygenated (de)protonated analytes, dehydrogenated deprotonated analytes, and negative ion adducts) were quite similar to those obtained from DART alone. This indicates a lack of side reactions due to the corona discharge. The change in the relative intensities of individual analyte-related ions due to the combination of a corona discharge system with DART suggests that there is no effect of the abundant excited helium in the analyte ionization area on the fragmentation processes or enhancement of oxidation due to hydroxyl radicals HO˙. Furthermore, it was found that the corona-DART combination can be applied to the highly sensitive analysis of n-alkanes, in which the alkanes are ionized as positive ions via hydride abstraction and oxidation, independent of the type of alkane or the mass spectrometer used.
NASA Astrophysics Data System (ADS)
Yan, Huijie; Yang, Liang; Qi, Xiaohua; Ren, Chunsheng
2015-02-01
The effect of a DC bias on the electrohydrodynamics (EHD) force induced by a surface dielectric barrier AC discharge actuator for airflow control at the atmospheric pressure is investigated. The measurement of the surface potential due to charge deposition at different DC biases is carried out by using a special designed corona like discharge potential probe. From the surface potential data, the plasma electromotive force is shown not affected much by the DC biases except for some reduction of the DC bias near the exposed electrode edge for the sheath-like configuration. The total thrust is measured by an analytical balance, and an almost linear relationship to the potential voltage at the exposed electrode edge is found for the direct thrust force. The temporally averaged ionic wind characteristics are investigated by Pitot tube sensor and schlieren visualization system. It is found that the ionic wind velocity profiles with different DC biases are almost the same in the AC discharge plasma area but gradually diversified in the further downstream area as well as the upper space away from the discharge plasma area. Also, the DC bias can significantly modify the topology of the ionic wind produced by the AC discharge actuator. These results can provide an insight into how the DC biases to affect the force generation.
Deployed communication between the Role 3 and Role 1.
Parsons, Iain T
2015-06-01
The discharge summary is the most common method for documenting a patient's diagnostic findings, hospital management and arrangements for post-discharge follow up. After being discharged from hospital, patients are routinely reviewed without a discharge summary being available. A recent review revealed that a significant proportion of patients discharged from the Role 3 had no evidence of their admission on their permanent medical record. The aim of this audit was to assess the transition of discharge summaries from Role 3 to Role 1 during Op HERRICK 18. The intention was to review where errors in the transfer of discharge information between Role 3 and Role 1 might be occurring with a view to implementing improvements. Two audits assessed the delivery of discharge information. A re-audit was performed 1 month after a system was implemented. The transfer of discharge information was poor with only 1/40 (2.5%) summaries arriving from R3 to R1. Following implementation of a system the transfer of discharge information improved to 24/30 (80%). The adoption of a system to transit discharge information from R3 to R1 resulted in a drastic improvement. Ideally, a future electronic patient record system used by all facets of Defence Medical Services would limit the potential for future adverse events due to communication failure. Regular audits assessing the transfer of discharge information should form part of standard audit cycles in future contingency operations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Colombia's discharge fee program: incentives for polluters or regulators?
Blackman, Allen
2009-01-01
Colombia's discharge fee system for water effluents is often held up as a model of a well-functioning, economic incentive pollution control program in a developing country. Yet few objective evaluations of the program have appeared. Based on a variety of primary and secondary data, this paper finds that in its first 5 years, the program was beset by a number of serious problems including limited implementation in many regions, widespread noncompliance by municipal sewerage authorities, and a confused relationship between discharge fees and emissions standards. Nevertheless, in some watersheds, pollution loads dropped significantly after the program was introduced. While proponents claim the incentives that discharge fees created for polluters to cut emissions in a cost-effective manner were responsible, this paper argues that the incentives they created for regulatory authorities to improve permitting, monitoring, and enforcement were at least as important.
NASA Technical Reports Server (NTRS)
Palmer, A. J.; Hess, L. D.; Stephens, R. R.; Pepper, D. M.
1977-01-01
The results of a two-year investigation into the possibility of developing continuous wave excimer lasers are reported. The program included the evaluation and selection of candidate molecular systems and discharge pumping techniques. The K Ar/K2 excimer dimer molecules and the xenon fluoride excimer molecule were selected for study; each used a transverse and capillary discharges pumping technique. Experimental and theoretical studies of each of the two discharge techniques applied to each of the two molecular systems are reported. Discharge stability and fluorine consumption were found to be the principle impediments to extending the XeF excimer laser into the continuous wave regime. Potassium vapor handling problems were the principal difficulty in achieving laser action on the K Ar/K2 system. Of the four molecular systems and pumping techniques explored, the capillary discharge pumped K Ar/K2 system appears to be the most likely candidate for demonstrating continuous wave excimer laser action primarily because of its predicted lower pumping threshold and a demonstrated discharge stability advantage.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Pinero, Luis; Haag, Thomas; Huang, Wensheng; Ahern, Drew; Liang, Ray; Shilo, Vlad
2016-01-01
NASAs Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This presentation presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation, open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thrusters discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.
Effect of discharge summary availability during post-discharge visits on hospital readmission.
van Walraven, Carl; Seth, Ratika; Austin, Peter C; Laupacis, Andreas
2002-03-01
To determine if the delivery of hospital discharge summaries to follow-up physicians decreases the risk of hospital readmission. Eight hundred eighty-eight patients discharged from a single hospital following treatment for an acute medical illness. Teaching hospital in a universal health-care system. We determined the date that each patient's discharge summary was printed and the physicians to whom it was sent. Summary receipt was confirmed by survey and phoning each physician's office. Each patient's hospital chart was reviewed to determine their acute and chronic medical conditions as well as their course in hospital. Using population-based administrative databases, all post-hospitalization visits were identified. For each of these visits, we determined whether the summary was available. Time to nonelective hospital readmission during 3 months following discharge. The discharge summary was available for only 568 of 4,639 outpatient visits (12.2%). Overall, 240 (27.0%) of patients were urgently readmitted to hospital. After adjusting for significant patient and hospitalization factors, we found a trend toward a decreased risk of readmission for patients who were seen in follow-up by a physician who had received a summary (relative risk 0.74, 95% confidence interval 0.50 to 1.11). The risk of rehospitalization may decrease when patients are assessed following discharge by physicians who have received the discharge summary. Further research is required to determine if better continuity of patient information improves patient outcomes.
Follow-on cable coupling lightning test, volume 1
NASA Technical Reports Server (NTRS)
Danforth, Richard
1990-01-01
A redesigned solid rocket motor test article was subjected to simulated lightning strikes. This test was performed to evaluate the effects of lightning strike to the redesigned motor and Space Transportation System. The purpose of the test was to evaluate the performance of systems tunnel design changes when subjected to the lightning discharges. The goal of the design changes was to reduce lightning induced coupling to cables within the systems tunnel. The test article was subjected to several different amounts and kinds of discharges. Changes in coupling levels detected during the tests are recorded. The dominant mode of coupling appears to be caused by the diffusion of the magnetic fields through the system tunnel covers. The results from bond strap integrity testing showed that 16 of 18 bond straps survived. Design change evaluations showed that coupling reduction ranged from 0 to 36 decibels for each type of cable. The type of cable has less effect on coupling than does strike location and strike levels. Recommendations for design changes are made.
Thermal Characterization Study of Lithium-Ion Cells
NASA Technical Reports Server (NTRS)
Britton, Doris L.; Miller, Thomas B.; Bennett, William R.
2007-01-01
The primary challenge in designing a full scale lithium-ion (Li-ion) battery system is safety under both normal operating as well as abusive conditions. The normal conditions involve expected charge/discharge cycles and it is known that heat evolves in batteries during those cycles. This is a major concern in the design for high power applications and careful thermal management is necessary to alleviate this concern. An emerging thermal measurement technology, such as the electrochemical calorimetric of batteries, will aid in the development of advanced, safe battery system. To support this technology, several "commercial-off-the-shelf" (COTS) Li-ion cells with different chemistries and designs are being evaluated for different cycling regimes at a given operating temperature. The Accelerated Rate Calorimeter (ARC)-Arbin cycler setup is used to measure the temperature, voltage, and current of the cells at different charge/discharge rates. Initial results demonstrated good cell cyclability. During the cycle testing, the cell exhibited an endothermic cooling in the initial part of the charge cycle. The discharge portion of the cycle is exothermic during the entire discharge period. The presence of an endothermic reaction indicates a significant entropy effect during the beginning of charge cycle. Further studies will be performed to understand the thermal characteristics of the Li-ion cells at the different operating conditions. The effects on the thermal response on cell aging and states-of-charge will also be identified.
Dogdu, Gamze; Yalcuk, Arda; Postalcioglu, Seda
2017-02-01
There are more than a hundred textile industries in Turkey that discharge large quantities of dye-rich wastewater, resulting in water pollution. Such effluents must be treated to meet discharge limits imposed by the Water Framework Directive in Turkey. Industrial treatment facilities must be required to monitor operations, keep them cost-effective, prevent operational faults, discharge-limit infringements, and water pollution. This paper proposes the treatment of actual textile wastewater by vertical flow constructed wetland (VFCW) systems operation and monitoring effluent wastewater quality using fuzzy logic with a graphical user interface. The treatment performance of VFCW is investigated in terms of chemical oxygen demand and ammonium nitrogen (NH4-N) content, color, and pH parameters during a 75-day period of operation. A computer program was developed with a fuzzy logic system (a decision- making tool) to graphically present (via a status analysis chart) the quality of treated textile effluent in relation to the Turkish Water Pollution Control Regulation. Fuzzy logic is used in the evaluation of data obtained from the VFCW systems and for notification of critical states exceeding the discharge limits. This creates a warning chart that reports any errors encountered in a reactor during the collection of any sample to the concerned party.
Optical emission spectroscopy of point-plane corona and back-corona discharges in air
NASA Astrophysics Data System (ADS)
Czech, T.; Sobczyk, A. T.; Jaworek, A.
2011-12-01
Results of spectroscopic investigations and current-voltage characteristics of corona discharge and back discharge on fly-ash layer, generated in point-plane electrode geometry in air at atmospheric pressure are presented in the paper. The characteristics of both discharges are similar but differ in the current and voltage ranges of all the discharge forms distinguished during the experiments. Three forms of back discharge, for positive and negative polarity, were investigated: glow, streamer and low-current back-arc. In order to characterize ionisation and excitation processes in back discharge, the emission spectra were measured and compared with those obtained for normal corona discharge generated in the same electrode configuration but with fly ash layer removed. The emission spectra were measured in two discharge zones: near the tip of needle electrode and near the plate. Visual forms of the discharge were recorded with digital camera and referred to current-voltage characteristics and emission spectra. The measurements have shown that spectral lines emitted by back discharge depend on the form of discharge and the discharge current. From the comparison of the spectral lines of back and normal discharges an effect of fly ash layer on the discharge morphology can be determined. The recorded emission spectra formed by ionised gas and plasma near the needle electrode and fly ash layer are different. It should be noted that in back arc emission, spectral lines of fly ash layer components can be distinguished. On the other hand, in needle zone, the emission of high intensity N2 second positive system and NO γ lines can be noticed. Regardless of these gaseous lines, also atomic lines of dust layer were present in the spectrum. The differences in spectra of back discharge for positive and negative polarities of the needle electrode have been explained by considering the kind of ions generated in the crater in fly ash layer. The aim of these studies is to better understand the discharge processes encountered in electrostatic precipitators.
Phenol degradation by TiO2 photocatalysts combined with different pulsed discharge systems.
Zhang, Yi; Lu, Jiani; Wang, Xiaoping; Xin, Qing; Cong, Yanqing; Wang, Qi; Li, Chunjuan
2013-11-01
Films of TiO2 nanotubes distributed over the inner surface of a discharge reactor cylinder (CTD) or adhered to a stainless steel electrode surface (PTD) in a discharge reactor were compared with a single-discharge (SD) system to investigate their efficiencies in phenol degradation. Morphology studies indicated that the TiO2 film was destroyed in the PTD system, but that there was no change in the CTD system after discharge. X-ray diffraction results revealed that the anatase phase of the original sample was preserved in the CTD system, but that an anatase-to-rutile phase transformation occurred in the PTD system after discharge. The highest efficiencies of phenol degradation and total organic carbon (TOC) mineralization were observed in the CTD system, and there was no decrease in phenol degradation efficiency upon reuse of a TiO2 film, indicating high catalysis activity and stability of the TiO2 photocatalysts in the combined treatment. TiO2 photocatalysts favored the formation of hydrogen peroxide and disfavored the formation of ozone. A greater degree of oxidation of intermediates and higher energy efficiency in phenol oxidation were observed with the TiO2-plasma systems, especially in the CTD system, compared to those with the SD system. Copyright © 2013 Elsevier Inc. All rights reserved.
Soil thaw effects on river discharge recessions of a subarctic catchment
NASA Astrophysics Data System (ADS)
Ploum, Stefan; Lyon, Steve; Teuling, Ryan; van der Velde, Ype
2017-04-01
Thawing permafrost in circumpolar regions is likely to change subsurface hydrology. In high latitude areas continuous permafrost is expected to partially thaw leading to sporadic permafrost with deeper groundwater flow paths. Moreover, freeze-thaw cycles of the shallow subsurface are likely to increase. River discharge recession analysis can be particularly useful to understand the hydrological effects of a thawing Arctic. Here we examine river discharge recessions of the Abiskojokka, a 560 km2 watershed with sporadic permafrost, using a river discharge record of 30 years (1985 - 2015). Snow observation records were used to separate river recessions in snowmelt and snowfree periods. We found significant differences between recessions during the snowmelt and snowfree seasons. During the snowmelt, recessions were close to linear (b=1.11), while during the snowfree period, recessions were more non-linear (b=1.54). Typically, non-linearity has been found to increase with discharge magnitude, while we observed the opposite (snowfree periods tend to have lower discharges than the snowmelt periods). We explain these contrasting results by hypothesizing that increased connectivity (increasing magnitude and number of water flow paths) between groundwater and stream leads to higher non-linearity. In temperate catchments without frozen soils, connectivity tends to increase with increasing discharge. In contrast, in Arctic systems, where soils are frozen, connectivity between groundwater and stream is limited. Therefore, thawing of frozen soils is expected to increase connectivity and thus non-linearity of river discharges. We tested this hypothesis with a detailed analysis of all spring flood recessions. Years with cold soil temperatures (b=1.08) and years with a below median snowpack depth were found to have progressively linear slopes (b=1.08 and 1.01 respectively). On the other hand, years with warm soil conditions show increasingly non-linear recessions (b=1.67). Although limited in spatial extent, these results further support our connectivity hypothesis, which predicts increasing non-linearity of river discharges (higher discharge peaks and lower low flows under the same precipitation regime) as permafrost thaws.
Mutzner, Lena; Staufer, Philipp; Ort, Christoph
2016-11-01
Wet-weather discharges contribute to anthropogenic micropollutant loads entering the aquatic environment. Thousands of wet-weather discharges exist in Swiss sewer systems, and we do not have the capacity to monitor them all. We consequently propose a model-based approach designed to identify critical discharge points in order to support effective monitoring. We applied a dynamic substance flow model to four substances representing different entry routes: indoor (Triclosan, Mecoprop, Copper) as well as rainfall-mobilized (Glyphosate, Mecoprop, Copper) inputs. The accumulation on different urban land-use surfaces in dry weather and subsequent substance-specific wash-off is taken into account. For evaluation, we use a conservative screening approach to detect critical discharge points. This approach considers only local dilution generated onsite from natural, unpolluted areas, i.e. excluding upstream dilution. Despite our conservative assumptions, we find that the environmental quality standards for Glyphosate and Mecoprop are not exceeded during any 10-min time interval over a representative one-year simulation period for all 2500 Swiss municipalities. In contrast, the environmental quality standard is exceeded during at least 20% of the discharge time at 83% of all modelled discharge points for Copper and at 71% for Triclosan. For Copper, this corresponds to a total median duration of approximately 19 days per year. For Triclosan, discharged only via combined sewer overflows, this means a median duration of approximately 10 days per year. In general, stormwater outlets contribute more to the calculated effect than combined sewer overflows for rainfall-mobilized substances. We further evaluate the Urban Index (A urban,impervious /A natural ) as a proxy for critical discharge points: catchments where Triclosan and Copper exceed the corresponding environmental quality standard often have an Urban Index >0.03. A dynamic substance flow analysis allows us to identify the most critical discharge points to be prioritized for more detailed analyses and monitoring. This forms a basis for the efficient mitigation of pollution. Copyright © 2016 Elsevier Ltd. All rights reserved.
Television Image of a Large Upward Electrical Discharge Above a Thunderstorm System
NASA Astrophysics Data System (ADS)
Franz, R. C.; Nemzek, R. J.; Winckler, J. R.
1990-07-01
An image of an unusual luminous electrical discharge over a thunderstorm 250 kilometers from the observing site has been obtained with a low-light-level television camera. The discharge began at the cloud tops at 14 kilometers and extended into the clear air 20 kilometers higher. The image, which had a duration of less than 30 milliseconds, resembled two jets or fountains and was probably caused by two localized electric charge concentrations at the cloud tops. Large upward discharges may create a hazard for aircraft and rocket launches and, by penetrating into the ionosphere, may initiate whistler waves and other effects on a magnetospheric scale. Such upward electrical discharges may account for unexplained photometric observations of distant lightning events that showed a low rise rate of the luminous pulse and no electromagnetic sferic pulse of the type that accompanies cloud-to-earth lightning strokes. An unusually high rate of such photometric events was recorded during the night of 22 to 23 September 1989 during a storm associated with hurricane Hugo.
Television image of a large upward electrical discharge above a thunderstorm system.
Franz, R C; Nemzek, R J; Winckler, J R
1990-07-06
An image of an unusual luminous electrical discharge over a thunderstorm 250 kilometers from the observing site has been obtained with a low-light-level television camera. The discharge began at the cloud tops at 14 kilometers and extended into the clear air 20 kilometers higher. The image, which had a duration of less than 30 milliseconds,resembled two jets or fountains and was probably caused by two localizd electric charge concentrations at the cloud tops. Large upward discharges may create a hazard for aircraft and rocket launches and, by penetrating into the ionosphere, may initiate whistler waves and other effects on a magnetospheric scale. Such upward electrical discharges may account for unexplained photometric observations of distant lightning events that showed a low rise rate of the luminous pulse and no electromagnetic sferic pulse of the type that accompanies cloud-to-earth lightning strokes. An unusually high rate of such photometric events was recorded during the night of 22 to 23 September 1989 during a storm associated with hurricane Hugo.
NASA Astrophysics Data System (ADS)
Li, Yanran; Chen, Duo; Li, Li; Zhang, Jiwei; Li, Guang; Liu, Hongxia
2017-11-01
GIS (gas insulated switchgear), is an important equipment in power system. Partial discharge plays an important role in detecting the insulation performance of GIS. UHF method and ultrasonic method frequently used in partial discharge (PD) detection for GIS. However, few studies have been conducted on comparison of this two methods. From the view point of safety, it is necessary to investigate UHF method and ultrasonic method for partial discharge in GIS. This paper presents study aimed at clarifying the effect of UHF method and ultrasonic method for partial discharge caused by free metal particles in GIS. Partial discharge tests were performed in laboratory simulated environment. Obtained results show the ability of anti-interference of signal detection and the accuracy of fault localization for UHF method and ultrasonic method. A new method based on UHF method and ultrasonic method of PD detection for GIS is proposed in order to greatly enhance the ability of anti-interference of signal detection and the accuracy of detection localization.
49 CFR 393.83 - Exhaust systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... combustible part of the motor vehicle. (b) No exhaust system shall discharge to the atmosphere at a location... gasoline engine shall discharge to the atmosphere at or within 6 inches forward of the rearmost part of the bus. (d) The exhaust system of a bus using fuels other than gasoline shall discharge to the atmosphere...
49 CFR 393.83 - Exhaust systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... combustible part of the motor vehicle. (b) No exhaust system shall discharge to the atmosphere at a location... gasoline engine shall discharge to the atmosphere at or within 6 inches forward of the rearmost part of the bus. (d) The exhaust system of a bus using fuels other than gasoline shall discharge to the atmosphere...
49 CFR 393.83 - Exhaust systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... combustible part of the motor vehicle. (b) No exhaust system shall discharge to the atmosphere at a location... gasoline engine shall discharge to the atmosphere at or within 6 inches forward of the rearmost part of the bus. (d) The exhaust system of a bus using fuels other than gasoline shall discharge to the atmosphere...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-01
... (NPDES) General Permit for Municipal Separate Storm Sewer Systems in the Middle Rio Grande Watershed in... Elimination System (NPDES) general permit for storm water discharges from municipal separate storm sewer... issued for various categories of storm water discharges. Section 402(p)(2) requires permits for five...
Research on Battery Energy Storage System Based on User Side
NASA Astrophysics Data System (ADS)
Wang, Qian; Zhang, Yichi; Yun, Zejian; Wang, Xuguang; Zhang, Dong; Bian, Di
2018-01-01
This paper introduces the effect of user side energy storage on the user side and the network side, a battery energy storage system for the user side is designed. The main circuit topology of the battery energy storage system based on the user side is given, the structure is mainly composed of two parts: DC-DC two-way half bridge converter and DC-AC two-way converter, a control strategy combining battery charging and discharging characteristics is proposed to decouple the grid side and the energy storage side, and the block diagram of the charging and discharging control of the energy storage system is given. The simulation results show that the battery energy storage system of the user side can not only realize reactive power compensation of low-voltage distribution network, but also improve the power quality of the users.
40 CFR 122.5 - Effect of a permit.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Effect of a permit. 122.5 Section 122.5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS EPA ADMINISTERED PERMIT PROGRAMS: THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Definitions and General...
40 CFR 122.5 - Effect of a permit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Effect of a permit. 122.5 Section 122.5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS EPA ADMINISTERED PERMIT PROGRAMS: THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Definitions and General...
Code of Federal Regulations, 2014 CFR
2014-07-01
... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...
Code of Federal Regulations, 2013 CFR
2013-07-01
... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...
Code of Federal Regulations, 2010 CFR
2010-07-01
... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...
Code of Federal Regulations, 2012 CFR
2012-07-01
... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...
Code of Federal Regulations, 2011 CFR
2011-07-01
... an approved oil discharge monitoring and control system or, if discharged before the required oil... mixture in the ballast. Use of an oil discharge monitoring and control system is not required. This... OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Vessel Operation § 157.43...
Novel Membrane Separation System for Shipboard Oily Wastewater Treatment
2010-12-01
OPNAVINST 5090.1B CH-2 regulates Navy ships to the same discharge limit for bilgewater and other oily waste discharges . Future discharge limits of...applicable to all Navy ship classes. An additional benefit is the potential to remove additional constituents of concern from bilgewater discharge ...treatment system on a Navy ship ................................................................ 26! 19. Shipboard Membrane Resistance of Full-Scale
Kitamura, Tatsuru; Shiota, Shigehito; Jinkawa, Shigetoshi; Kitamura, Maki; Hino, Shoryoku
2018-01-01
During hospitalization for behavioural and psychological symptoms of dementia (BPSD), it is imperative to build a support system for each patient in the community for after they obtain symptom remission. To this end, patients lacking adequate family support are less likely to be discharged to their own homes and need stronger support systems to be established. This study therefore investigated the effects of home-visit nursing before admission on time to home discharge among patients with limited familial care who were hospitalized for treatment of BPSD. A single-centre chart review study was conducted on consecutive patients admitted from home between April 2013 and September 2015 for treatment of BPSD and who had lived alone or with a working family member. Time to home discharge was compared between patients who had home-visit nursing before their admission and those who did not. In total, 58 patients were enrolled in the study, of whom 12 had preceding home-visit nursing (PHN group) and 46 did not (non-PHN group). Patients in the PHN group were younger (77.7 ± 4.9 vs. 84.1 ± 6.1 years, P = 0.0011) and had higher Mini-Mental State Examination scores (16.8 ± 7.2 vs 11.8 ± 7.3, P = 0.0287). A multivariate Cox proportional hazard regression analysis adjusted for age and Mini-Mental State Examination scores showed a higher likelihood of discharge to home in the PHN group (hazard ratio: 3.85; 95% confidence interval: 1.27-11.6;, P = 0.017) than in the non-PHN group. Home-visit nursing before admission of BPSD patients for treatment could improve the rate of discharge to home among patients with limited familial care after subsequent hospitalization. Home-visit nursing could also enhance collaborative relationships between social and hospital-based care systems, and early implementation could improve the likelihood of vulnerable patient types remaining in their own homes for as long as possible. © 2018 Japanese Psychogeriatric Society.
Li, Hao; Zhang, Gaofei; Ma, Rui; You, Zheng
2014-01-01
An effective multisource energy harvesting system is presented as power supply for wireless sensor nodes (WSNs). The advanced system contains not only an expandable power management module including control of the charging and discharging process of the lithium polymer battery but also an energy harvesting system using the maximum power point tracking (MPPT) circuit with analog driving scheme for the collection of both solar and vibration energy sources. Since the MPPT and the power management module are utilized, the system is able to effectively achieve a low power consumption. Furthermore, a super capacitor is integrated in the system so that current fluctuations of the lithium polymer battery during the charging and discharging processes can be properly reduced. In addition, through a simple analog switch circuit with low power consumption, the proposed system can successfully switch the power supply path according to the ambient energy sources and load power automatically. A practical WSNs platform shows that efficiency of the energy harvesting system can reach about 75-85% through the 24-hour environmental test, which confirms that the proposed system can be used as a long-term continuous power supply for WSNs.
Li, Hao; Zhang, Gaofei; Ma, Rui; You, Zheng
2014-01-01
An effective multisource energy harvesting system is presented as power supply for wireless sensor nodes (WSNs). The advanced system contains not only an expandable power management module including control of the charging and discharging process of the lithium polymer battery but also an energy harvesting system using the maximum power point tracking (MPPT) circuit with analog driving scheme for the collection of both solar and vibration energy sources. Since the MPPT and the power management module are utilized, the system is able to effectively achieve a low power consumption. Furthermore, a super capacitor is integrated in the system so that current fluctuations of the lithium polymer battery during the charging and discharging processes can be properly reduced. In addition, through a simple analog switch circuit with low power consumption, the proposed system can successfully switch the power supply path according to the ambient energy sources and load power automatically. A practical WSNs platform shows that efficiency of the energy harvesting system can reach about 75–85% through the 24-hour environmental test, which confirms that the proposed system can be used as a long-term continuous power supply for WSNs. PMID:25032233
Modeling of glow discharge in a gas flow
NASA Astrophysics Data System (ADS)
Galeev, I. G.; Asadullin, T. Ya
2017-11-01
The discharge plasma of positive column in electronegative gas flow has been described by two-dimensional integro-differential system of equations written in the approximation of “narrow channel”. An efficient algorithm of solving this system of equations is suggested. In this work an implicit method is used of solution with selection gradient of the electric field along the channel. The simulation of discharge characteristics was conducted under various boundary conditions at the inlet of the discharge area and with various full discharge currents.
Pulsed plasma processing for control of diesel engine emissions
NASA Astrophysics Data System (ADS)
Vogtlin, G. E.; Freytag, E. K.; Bardsley, J. N.; Wallman, H.
1993-02-01
Electrical discharges can be used as an after treatment for diesel exhaust. We are presently involved in research to determine the feasibility of this process. These discharges have been shown to remove nitric oxide, sulfur dioxide, particulates, and many organic compounds. A key issue is the efficiency of this removal since it effects both capital and operating costs. These discharges must be of short duration, less than one microsecond, to avoid energy losses due to heating of bulk gas molecules. The voltage must be kept below the voltage breakdown limit where ion heating creates an arc discharge. The basic process is the acceleration of electrons which then collide with gas molecules to form radicals such as O and OH. These radicals then react with and eliminate pollutants. Two basic electrode geometries are used to generate these discharges. The barrier discharge is when one or both of the electrodes is insulated and the pulse length is limited by charging of the insulator. This discharge must be driven by alternating current to permit alternating charging of the insulator. The other geometry is when one electrode has a peak voltage stress five or more times the average stress. We have been investigating the high stress geometry which uses a small wire inside a pipe. The principal experimental apparatus utilized by this effort uses a closed loop gas system. This system permits the production of various gas combinations prior to testing. Analysis can be conducted during or after these tests. The recirculated gas can be heated up to 400 F. This system can measure the energy used and the pollutant removal to determine efficiency. Our primary goal is the simultaneous removal of nitric oxide and particulates typical of diesel exhaust.
High-frequency underwater plasma discharge application in antibacterial activity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, M. W.; Choi, S.; Lyakhov, K.
Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O{sub 2}) injected and hydrogen peroxide (H{sub 2}O{sub 2}) added discharge in water was achieved. The effect of H{sub 2}O{sub 2} dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H{sub 2}O{sub 2} addition with O{sub 2} injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population onmore » the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH{sup •}, H, and O). Interestingly, the results demonstrated that O{sub 2} injected and H{sub 2}O{sub 2} added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.« less
Gas discharge headlights and visibility of coloured road signs.
Venkatachalam, Kannan; Smith, George
2000-01-01
BACKGROUND: Automotive headlamps mostly use the tungsten halogen bulb but several years ago a new type of headlamp, the gas discharge bulb, was introduced. Because of the different spectral output of this type of lamp, there has been a suggestion that it may affect the colour recognition and sign conspicuity under night-time conditions. In this study, the visibility of the road signs is used to examine the effect of the gas discharge lamp's spectrum compared with that of the conventional halogen headlamp. METHODS: The spectral output of the lamps and the spectral reflectance of common-coloured road signs were measured using a Spectra-Pritchard spectroradiometer. Using luminous reflectance data, chromaticity co-ordinates and the colorimetric shift of the road signs, when illuminated by gas discharge lamps, were plotted using CIE x,y co-ordinate system. Colour rendering indices of the lamp were calculated using Munsell samples and road signs as proscribed by the CIE Publication. In addition, the visibility index of the road signs was calculated using Adrian's 'Visibility of Target' model. RESULTS: The gas discharge headlamp has more energy in the blue region and less energy in the red region of the spectrum than the halogen headlamp. The general colour rendering index of the gas discharge lamp is higher than that of the halogen lamp. When compared with daylight, all coloured road signs used in this study have less colorimetric shift when illuminated by the gas discharge headlamp than by the halogen headlamp. CONCLUSION: The result indicates that the gas discharge lamp, while having a very different spectrum from daylight or tungsten halogen lamps, should not have a deleterious effect on sign detection or recognition, when compared to daylight or tungsten halogen lamps.
High-frequency underwater plasma discharge application in antibacterial activity
NASA Astrophysics Data System (ADS)
Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U.; Mongre, R. K.; Jeong, D. K.; Suresh, R.; Lee, H. J.
2017-03-01
Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli ( E. coli) by generating high-frequency, high-voltage, oxygen (O2) injected and hydrogen peroxide (H2O2) added discharge in water was achieved. The effect of H2O2 dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H2O2 addition with O2 injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH•, H, and O). Interestingly, the results demonstrated that O2 injected and H2O2 added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.
Secondary preventive medication persistence and adherence 1 year after stroke.
Bushnell, C D; Olson, D M; Zhao, X; Pan, W; Zimmer, L O; Goldstein, L B; Alberts, M J; Fagan, S C; Fonarow, G C; Johnston, S C; Kidwell, C; Labresh, K A; Ovbiagele, B; Schwamm, L; Peterson, E D
2011-09-20
Data on long-term use of secondary prevention medications following stroke are limited. The Adherence eValuation After Ischemic stroke-Longitudinal (AVAIL) Registry assessed patient, provider, and system-level factors influencing continuation of prevention medications for 1 year following stroke hospitalization discharge. Patients with ischemic stroke or TIA discharged from 106 hospitals participating in the American Heart Association Get With The Guidelines-Stroke program were surveyed to determine their use of warfarin, antiplatelet, antihypertensive, lipid-lowering, and diabetes medications from discharge to 12 months. Reasons for stopping medications were ascertained. Persistence was defined as continuation of all secondary preventive medications prescribed at hospital discharge, and adherence as continuation of prescribed medications except those stopped according to health care provider instructions. Of the 2,880 patients enrolled in AVAIL, 88.4% (2,457 patients) completed 1-year interviews. Of these, 65.9% were regimen persistent and 86.6% were regimen adherent. Independent predictors of 1-year medication persistence included fewer medications prescribed at discharge, having an adequate income, having an appointment with a primary care provider, and greater understanding of why medications were prescribed and their side effects. Independent predictors of adherence were similar to those for persistence. Although up to one-third of stroke patients discontinued one or more secondary prevention medications within 1 year of hospital discharge, self-discontinuation of these medications is uncommon. Several potentially modifiable patient, provider, and system-level factors associated with persistence and adherence may be targets for future interventions.
Effect of pulsed corona discharge voltage and feed gas flow rate on dissolved ozone concentration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prasetyaningrum, A., E-mail: ajiprasetyaningrum@gmail.com; Ratnawati,; Jos, B.
Ozonization is one of the methods extensively used for water purification and degradation of organic materials. Ozone (O{sub 3}) is recognized as a powerful oxidizing agent. Due to its strong oxidability and better environmental friendless, ozone increasing being used in domestic and industrial applications. Current technology in ozone production utilizes several techniques (corona discharge, ultra violet radiation and electrolysis). This experiment aimed to evaluating effect of voltage and gas flow rate on ozone production with corona discharge. The system consists of two net-type stainless steel electrode placed in a dielectric barrier. Three pulsed voltage (20, 30, 40 KV) and flowmore » rate (5, 10, 15 L/min) were prepare for operation variable at high frequency (3.7 kHz) with AC pulsed power supply. The dissolved ozone concentration depends on the applied high-voltage level, gas flow rate and the discharge exposure duration. The ozone concentration increases with decreasing gas flow rate. Dissolved ozone concentrations greater than 200 ppm can be obtained with a minimum voltage 40 kV.« less
High voltage testing for the Majorana Demonstrator
Abgrall, N.; Arnquist, I. J.; Avignone, III, F. T.; ...
2016-04-04
The Majorana Collaboration is constructing the Majorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the Majorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of themore » high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during the Majorana Demonstrator commissioning phase were studied. Furthermore, a stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.« less
High voltage testing for the Majorana Demonstrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.
2016-07-01
The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path,more » including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.« less
Effect of pulsed corona discharge voltage and feed gas flow rate on dissolved ozone concentration
NASA Astrophysics Data System (ADS)
Prasetyaningrum, A.; Ratnawati, Jos, B.
2015-12-01
Ozonization is one of the methods extensively used for water purification and degradation of organic materials. Ozone (O3) is recognized as a powerful oxidizing agent. Due to its strong oxidability and better environmental friendless, ozone increasing being used in domestic and industrial applications. Current technology in ozone production utilizes several techniques (corona discharge, ultra violet radiation and electrolysis). This experiment aimed to evaluating effect of voltage and gas flow rate on ozone production with corona discharge. The system consists of two net-type stainless steel electrode placed in a dielectric barrier. Three pulsed voltage (20, 30, 40 KV) and flow rate (5, 10, 15 L/min) were prepare for operation variable at high frequency (3.7 kHz) with AC pulsed power supply. The dissolved ozone concentration depends on the applied high-voltage level, gas flow rate and the discharge exposure duration. The ozone concentration increases with decreasing gas flow rate. Dissolved ozone concentrations greater than 200 ppm can be obtained with a minimum voltage 40 kV.
Experimental study of a vertical jet in a vegetated crossflow.
Ben Meftah, Mouldi; De Serio, Francesca; Malcangio, Daniela; Mossa, Michele; Petrillo, Antonio Felice
2015-12-01
Aquatic ecosystems have long been used as receiving environments of wastewater discharges. Effluent discharge in a receiving water body via single jet or multiport diffuser, reflects a number of complex phenomena, affecting the ecosystem services. Discharge systems need to be designed to minimize environmental impacts. Therefore, a good knowledge of the interaction between effluents, discharge systems and receiving environments is required to promote best environmental management practice. This paper reports innovative 3D flow velocity measurements of a jet discharged into an obstructed crossflow, simulating natural vegetated channel flows for which correct environmental management still lacks in literature. In recent years, numerous experimental and numerical studies have been conducted on vegetated channels, on the one hand, and on turbulent jets discharged into unvegetated crossflows, on the other hand. Despite these studies, however, there is a lack of information regarding jets discharged into vegetated crossflow. The present study aims at obtaining a more thorough understanding of the interaction between a turbulent jet and an obstructed crossflow. In order to achieve such an objective, a series of laboratory experiments was carried out in the Department of Civil, Environmental, Building Engineering and Chemistry of the Technical University of Bari - Italy. The physical model consists of a vertical jet discharged into a crossflow, obstructed by an array of vertical, rigid, circular and threaded steel cylinders. Analysis of the measured flow velocities shows that the array of emergent rigid vegetation significantly affects the jet and the ambient flow structures. It reduces the mean channel velocity, allowing the jet to penetrate higher into the crossflow. It significantly increases the transversal flow motion, promoting a major lateral spreading of the jet within the crossflow. Due to the vegetation array effects, the jet undergoes notable variations in its vortical structure. The variation of the flow patterns affects the mixing process and consequently the dilution of pollutants discharged in receiving water bodies. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zeng, Jiansheng; Qian, Suyun; Zheng, Mingqiong; Wang, Yin; Zhou, Gaojun; Wang, Haiyan
2013-12-01
To investigate the epidemiology and resuscitation effects of cardiopulmonary arrest among hospitalized children and adolescents in Beijing. A prospective multicentre study was conducted in four hospitals in urban/suburban areas of Beijing. Patients aged 1 month-18 years with cardiopulmonary arrest and received cardiopulmonary resuscitation (CPR) who were consecutively hospitalised during the study period (1 September 2008-31 December 2010) were enrolled. Data was collected and analyzed using the "in-hospital Utstein style". Neurological outcome was assessed with the pediatric cerebral performance category (PCPC) among patients who survived. 201 of 108,673 hospitalized patients (0.18%) had cardiopulmonary arrest during their hospitalization. Of these, 174 patients underwent CPR. The most common causes of cardiopulmonary arrest were the diseases of respiratory system (29.3%) and circulatory system (19.0%). The most common initial rhythm was bradycardia (72.4%). About 108 patients (62.1%) had restoration of spontaneous circulation (ROSC). Forty-nine patients (28.2%) survived to hospital discharge, 25 (14.5%) survived 6 months post discharge, and 21 (12.1%) survived 1 year post discharge. Out of the 21 patients who survived 1 year after hospital discharge, 18 had good neurological outcome. Multivariate logistic regression analysis showed age, duration of CPR and endotracheal intubation performed before cardiopulmonary arrest were independent factors of cardiopulmonary resuscitation effect. The prevalence of in-hospital cardiopulmonary arrest in children and adolescents is low. The long-term result of children and adolescents survived from cardiopulmonary resuscitation is quite good. Age, CPR duration and endotracheal intubation performed before cardiopulmonary arrest were independent factors of cardiopulmonary resuscitation effect. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
High energy density primary batteries
NASA Technical Reports Server (NTRS)
Horning, R. J.; Beck, W. R.
1972-01-01
By the use of fractional factorials, paths of steepest ascent and direct comparison experimentation, performance characteristics of the CuF2/LiAsF6-MF/Li electrochemical system were optimized under conditions of temperature environment, discharge rate, active stand, and use of anhydrous cathodes. Two hundred ampere-hours/lb of CuF2 and 600 watt-hours/lb of CuF2 were achieved in anhydrous cells at plus 40 C and at a discharge rate of 10 ma sq cm. Electrical performance is primarily altered by temperature and discharge rate; however, other factors such as cathode water content, cathode conductor content, separator thickness, and the use of SO2 gas also have significant effects.
Large springs of east Tennessee
Sun, Pao-chang P.; Criner, J.H.; Poole, J.L.
1963-01-01
Springs constitute an important source of water in east Tennessee, and many individual springs are capable of supplying the large quantities needed for municipal and industrial supplies. Most of the springs in east Tennessee issue from solution openings and fractured and faulted zones in limestone and dolomite of the Knox Group, Chickamauga Limestone, and Conasauga Group. The ability of these rocks to yield a sustained flow of water to springs is dependent on a system of interconnected openings through which water can infiltrate from the land surface and move to points of natural discharge. Ninety springs were selected for detailed study, and 84 of these are analyzed in terms of magnitude and variability of discharge. Of the 84 springs analyzed, 4 flow at an average rate of 10 to 100 cfs (cubic feet per second), 62 at an average rate of 1 to 10 cfs, and 18 at an average rate of 1 cfs or less. Of the 90 springs, 75 are variable in their discharge; that is, the ratio of their fluctuations to their average discharges exceeds 100 percent. Mathematical analysis of the flow recession curve of Mill Spring near Jefferson City shows that the hydrologic system contributing to the flow of the spring has an effective capacity of about 70 million cubic feet of water. The rate of depletion of this volume of water, in the absence of significant precipitation, averages 0.0056 cfs per day between the time when the hydrologic system is full and the time when the spring ceases to flow. From such a curve it is possible to determine at any time the residual volume of water remaining in the system and the expected rate of decrease in discharge from that time to cessation of flow. Correlation of discharge measurements of 22 springs with those of Mill Spring shows that rough approximations of discharge can be projected for springs for which few measurements are available. Seventeen of the springs analyzed in this manner show good correlation with Mill Spring: that is, their coefficients of correlation were 0.70 or better as compared with a perfect correlation factor of 1.00.
Cabral, Mathilde; Toure, Aminata; Garçon, Guillaume; Diop, Cheikh; Bouhsina, Saâd; Dewaele, Dorothée; Cazier, Fabrice; Courcot, Dominique; Tall-Dia, Anta; Shirali, Pirouz; Diouf, Amadou; Fall, Mamadou; Verdin, Anthony
2015-11-01
The purpose of the study was to determine Pb and Cd concentrations in humans and to assess the effect of co-exposure to these metals on biomarkers of oxidative stress and nephrotoxicity. Blood and urine levels of Pb and Cd, oxidative stress and urinary renal biomarkers were measured in 77 subjects neighboring a discharge and 52 in the control site. Exposed subjects showed significantly higher levels of lead and cadmium in blood and urine than the controls. Excessive production of reactive oxygen species induced by these metals in exposed subjects conducted to a decrease in antioxidant defense system (GPx, Selenium, GSH) and an increase in lipid peroxidation (MDA). Moreover, changes in markers of nephrotoxicity (high urinary concentrations of total protein, RBP and CC16, as well as GSTα and LDH increased activities) suggested the occurrence of discrete and early signs of impaired renal function for the discharge neighboring population. Copyright © 2015 Elsevier Ltd. All rights reserved.
Multi-spark discharge system for preparation of nutritious water
NASA Astrophysics Data System (ADS)
Nakaso, Tetsushi; Harigai, Toru; Kusumawan, Sholihatta Aziz; Shimomura, Tomoya; Tanimoto, Tsuyoshi; Suda, Yoshiyuki; Takikawa, Hirofumi
2018-01-01
The nitrogen compound concentration in water is increased by atmospheric-pressure plasma discharge treatment. A rod-to-water electrode discharge treatment system using plasma discharge has been developed by our group to obtain water with a high concentration of nitrogen compounds, and this plasma-treated water improves the growth of chrysanthemum roots. However, it is difficult to apply the system to the agriculture because the amount of treated water obtained by using the system too small. In this study, a multi-spark discharge system (MSDS) equipped multiple spark plugs is presented to obtain a large amount of plasma-treated water. The MSDS consisted of inexpensive parts in order to reduce the system introduction cost for agriculture. To suppress the temperature increase of the spark plugs, the 9 spark plugs were divided into 3 groups, which were discharged in order. The plasma-treated water with a NO3- concentration of 50 mg/L was prepared using the MSDS for 90 min, and the treatment efficiency was about 6 times higher than that of our previous system. It was confirmed that the NO2-, O3, and H2O2 concentrations in the water were also increased by treating the water using the MSDS.
Methods for accurate estimation of net discharge in a tidal channel
Simpson, M.R.; Bland, R.
2000-01-01
Accurate estimates of net residual discharge in tidally affected rivers and estuaries are possible because of recently developed ultrasonic discharge measurement techniques. Previous discharge estimates using conventional mechanical current meters and methods based on stage/discharge relations or water slope measurements often yielded errors that were as great as or greater than the computed residual discharge. Ultrasonic measurement methods consist of: 1) the use of ultrasonic instruments for the measurement of a representative 'index' velocity used for in situ estimation of mean water velocity and 2) the use of the acoustic Doppler current discharge measurement system to calibrate the index velocity measurement data. Methods used to calibrate (rate) the index velocity to the channel velocity measured using the Acoustic Doppler Current Profiler are the most critical factors affecting the accuracy of net discharge estimation. The index velocity first must be related to mean channel velocity and then used to calculate instantaneous channel discharge. Finally, discharge is low-pass filtered to remove the effects of the tides. An ultrasonic velocity meter discharge-measurement site in a tidally affected region of the Sacramento-San Joaquin Rivers was used to study the accuracy of the index velocity calibration procedure. Calibration data consisting of ultrasonic velocity meter index velocity and concurrent acoustic Doppler discharge measurement data were collected during three time periods. Two sets of data were collected during a spring tide (monthly maximum tidal current) and one of data collected during a neap tide (monthly minimum tidal current). The relative magnitude of instrumental errors, acoustic Doppler discharge measurement errors, and calibration errors were evaluated. Calibration error was found to be the most significant source of error in estimating net discharge. Using a comprehensive calibration method, net discharge estimates developed from the three sets of calibration data differed by less than an average of 4 cubic meters per second, or less than 0.5% of a typical peak tidal discharge rate of 750 cubic meters per second.
Effect of discharge duct geometry on centrifugal fan performance and noise emission
NASA Astrophysics Data System (ADS)
Nelson, David A.; Butrymowicz, William; Thomas, Christopher
2005-09-01
Non-ideal inlet and discharge duct geometries can cause significant changes to both the aerodynamic performance (``fan curve'') and specific sound power emission of a fan. A proper understanding of actual installed performance, as well as a good estimate of the system backpressure curve, is critical to achieving flow and acoustic goals as well as other criteria such as power consumption, mass and volume. To this end a battery of ISO 10302 tests was performed on a blower assembly which supports the Advanced Animal Habitat, being developed by ORBITEC for deployment on the International Space Station. The blower assembly consists of (4) identical centrifugal fans that, amongst themselves and across two prototypes, incorporated several discharge geometries. The inlet geometries were identical in all cases. Thus by comparing the dimensionless pressure-flow and noise emission characteristics across the cases, significant insight into the nature and potential magnitude of these effects is gained.
Measuring the degradation level of polymer films subjected to partial discharges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bozzo, R.; Gemme, C.; Guastavino, F.
1996-12-31
Polymer films have been subjected to partial discharge (PD) aging. It is shown that statistical quantities derived from partial discharges patterns can be related to test conditions, film characteristics and degradation level. PDs have been measured by means of a digital system. Several resulting PD patterns have been elaborated and about 50 derived and statistical quantities have been obtained for each pattern. The effects of the test conditions on the derived quantities has been studied with relevance to the following items: To recognize the kind of film under test; to correlate the value of quantities with the degradation level ofmore » the film (i.e., to focus at the quantities which change with time); to find a link between the quantities values and the test ambient conditions (i.e., relative humidity); to determine the influence of the film thickness; and to evidence the effect of the voltage level.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... drainage from diked storage areas by valves to prevent a discharge into the drainage system or facility... facility drainage systems from undiked areas with a potential for a discharge (such as where piping is... pumps. Whatever techniques you use, you must engineer facility drainage systems to prevent a discharge...
Bell, Jr., Harold S.
1979-01-01
This invention sets forth a double-acting piston, which carries a floating piston, and which is reciprocated in a housing, for feeding coal to a high pressure gasifier system. The housing has a plurality of solids (for instance: coal) in-feeding ports and a single discharge port, the latter port being in communication with a high pressure gasifier system. The double-acting piston sequentially and individually communicates each of the in-feeding ports with the discharge port. The floating piston both seals off the discharge port while each in-feeding port is receiving coal or the like, to prevent undue escape of gas from the gasifier system, and translates in the housing, following a discharge of coal or the like into the discharge port, to return gas which has been admitted into the housing back into the gasifier system.
Continuous pressure letdown system
Sprouse, Kenneth M.; Matthews, David R.; Langowski, Terry
2010-06-08
A continuous pressure letdown system connected to a hopper decreases a pressure of a 2-phase (gas and solid) dusty gas stream flowing through the system. The system includes a discharge line for receiving the dusty gas from the hopper, a valve, a cascade nozzle assembly positioned downstream of the discharge line, a purge ring, an inert gas supply connected to the purge ring, an inert gas throttle, and a filter. The valve connects the hopper to the discharge line and controls introduction of the dusty gas stream into the discharge line. The purge ring is connected between the discharge line and the cascade nozzle assembly. The inert gas throttle controls a flow rate of an inert gas into the cascade nozzle assembly. The filter is connected downstream of the cascade nozzle assembly.
Modification of medullary respiratory-related discharge patterns by behaviors and states of arousal.
Chang, F C
1992-02-07
The modulatory influences of behaviors and states of arousal on bulbar respiratory-related unit (RRU) discharge patterns were studied in an unanesthetized, freely behaving guinea pig respiratory model system. When fully instrumented, this model system permits concurrent monitoring and recording of (i) single units from either Bötzinger complex or nucleus para-ambiguus; (ii) electrocorticogram; and, (iii) diaphragmatic EMG. In addition to being used in surveys of RRU discharge patterns in freely behaving states, the model system also offered a unique opportunity in investigating the effects of pentobarbital on RRU discharge patterns before, throughout the course of, and during recovery from anesthesia. In anesthetized preparations, a particular RRU discharge pattern (such as tonic, incrementing or decrementing) typically displayed little, if any notable variation. The most striking development following pentobarbital was a state of progressive bradypnea attributable to a significantly augmented RRU cycle duration, burst duration and an increase in the RRU spike frequencies during anesthesia. In freely behaving states, medullary RRU activities rarely adhered to a fixed, immutable discharge pattern. More specifically, the temporal organization (such as burst duration, cycle duration, and the extent of modulation of within-burst spike frequencies) of RRU discharge patterns regularly showed complex and striking variations, not only with states of arousal (sleep/wakefulness, anesthesia) but also with discrete alterations in electrocorticogram (ECoG) activities and a multitude of on-going behavioral repertoires such as volitional movement, postural modification, phonation, mastication, deglutition, sniffing/exploratory behavior, alerting/startle reflexes. Only during sleep, and on occasions when the animal assumed a motionless, resting posture, could burst patterns of relatively invariable periodicity and uniform temporal attributes be observed. RRU activities during sniffing reflex is worthy of further note in that, based on power spectrum analyses of concurrently recorded ECoG activities, this particular discharge pattern was clearly associated with the activation of a 6-10 Hz theta rhythm. These findings indicated that bulbar RRU activity patterns are subject to change by not only behaviors and sleep/wakefulness cycles, but also a variety of modulatory influences and feedback/feedforward biases from other central and peripheral physiological control mechanisms.
40 CFR 125.120 - Scope and purpose.
Code of Federal Regulations, 2010 CFR
2010-07-01
....120 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Ocean Discharge Criteria § 125.120 Scope... Elimination System (NPDES) permits for the discharge of pollutants from a point source into the territorial...
40 CFR 125.120 - Scope and purpose.
Code of Federal Regulations, 2011 CFR
2011-07-01
....120 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Ocean Discharge Criteria § 125.120 Scope... Elimination System (NPDES) permits for the discharge of pollutants from a point source into the territorial...
Study on energy saving effect of IHX on vehicle air conditioning system
NASA Astrophysics Data System (ADS)
Li, Huguang; Tong, Lin; Xu, Ming; Wei, Wangrui; Zhao, Meng; Wang, Long
2018-02-01
In this paper, the performance of Internal Heat Exchanger (IHX) air conditioning system for R134a is investigated in bench test and vehicle test. Comparison for cooling capacity and energy consumption between IHX air conditioning system and traditional tube air conditioning system are conducted. The suction temperature and discharge temperature of compressor is also recorded. The results show that IHX air conditioning system has higher cooling capacity, the vent temperature decrease 2.3 °C in idle condition. But the suction temperature and discharge temperature of compressor increase 10°C. IHX air conditioning system has lower energy consumption than traditional tube air conditioning system. Under the experimental conditions in this paper, the application of IHX can significantly reduce the energy consumption of air conditioning system. At 25°C of environment temperature, AC system energy consumption decrease 14%, compressor energy consumption decrease 16%. At 37°C of environment temperature, AC system energy consumption decrease 16%, compressor energy consumption decrease 13%.
Sevick, Laura K; Santana, Maria-Jose; Ghali, William A; Clement, Fiona
2017-01-01
Objective To complete an economic evaluation within a randomised controlled trial (RCT) comparing the use of an electronic discharge communication tool (eDCT) compared with usual care. Setting Patients being discharged from a single tertiary care centre’s internal medicine Medical Teaching Units. Participants Between January 2012 and December 2013, 1399 patients were randomised to a discharge mechanism. Forty-five patients were excluded from the economic evaluation as they did not have data for the index hospitalisation cost; 1354 patients contributed to the economic evaluation. Intervention eDCT generated at discharge containing structured content on reason for admission, details of the hospital stay, treatments received and follow-up care required. The control group was discharged via traditional dictation methods. Primary and secondary outcome measures The primary economic outcome was the cost per quality-adjusted life year (QALY) gained. Secondary outcomes included the cost per death avoided and the cost per readmission avoided. Results The average transcription cost was $C22.28 per patient, whereas the estimated cost of the eDCT was $C13.33 per patient. The cost per QALY gained was $C239 933 in the eDCT arm compared with usual care due to the very small gains in effectiveness and approximately $C800difference in resource utilisation costs. The bootstrap analyses resulted in eDCT being more effective and more costly in 29.2% of samples, less costly and more effective in 29.2% of samples, less effective and more costly in 23.9% of samples and finally, less costly and less effective in 17.7% of samples. Conclusions The eDCT reduced per patient costs of the generation of discharge summaries. The bootstrap estimates demonstrate considerable uncertainty supporting the finding of neutrality reported in the clinical component of the RCT. The immediate transcription cost savings and previously documented provider and patient satisfaction may increase the impetus for organisations to invest in such systems, provided they have a foundation of eHealth infrastructure and readiness. Trial registration number NCT01402609. PMID:29247110
The penalty points system in Ireland - Does it remain effective 14 years on?
Downey, C; Donnelly, M
2018-06-01
Road traffic accidents (RTAs) are the leading cause of trauma related mortality in Ireland. The penalty points system (PPS) was introduced in Ireland in 2002 to incentivise safer driving and reduce injury. Its early effect was studied previously 1 which concluded that there was a slight reduction in RTA related femoral shaft fractures (a sensitive indicator of high energy trauma) and a dramatic reduction in RTA related discharges. We hypothesized that over the following 14 years, the penalty points system might lose its effectiveness. Data was again collected from the same HIPE departments from six Dublin teaching hospitals and also University Hospital Waterford (to represent both an urban and a more rural population cohort respectively) examining RTA related femoral shaft fractures over an identical 6 month period (October-April). RTA related discharge data over an identical 6 month period was again acquired and analysed from Beaumont Hospital, Dublin (identical data source to previous study). These results were compared with the identical 6 month period in 2001/02 & 2002/03 (October-April). The total number of RTA related femoral shaft fracture discharges in Dublin decreased from 16 post introduction of PPS in the 2002/03 6-month period to 7 in 2015/16 6-month period. The number remained the same in the Waterford region (n = 5). The total RTA related discharges in Beaumont Hospital, Dublin decreased from 70 post PPS introduction to 57 in the 2015/16 6-month period. This represents an incidence rate of 4.5/1000 discharges (vs 6.9 post introduction) which was a statistically significant reduction (p = 0.014). The mean length of stay for these patients reduced from 13 to 7.7 days. There were consistent reductions in head injury (major & minor), lower limb fracture and facial fracture since the introduction of the PPS. The upper limb, pelvic/acetabular and thoracic injuries remained largely unchanged. Whilst RTA related spinal and abdominal injuries decreased after the introduction of the PPS, this study shows that these injuries have unfortunately increased since the post-PPS study in 2002/03. These results further support the effectiveness of the penalty points system and at a time where road death figures are under the spotlight, endorse the efficacious strategies implemented by the road safety authority in Ireland. Copyright © 2017 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Gao, Liang; Feng, Chun-Lei; Wang, Zhi-Wei; Ding, Hongbin
2017-05-01
The current paucity of spatial and temporal characterization of reactive oxygen and nitrogen species (RONS) concentration has been a major hurdle to the advancement and clinical translation of low temperature atmospheric plasmas. In this study, an advanced laser induced fluorescence (LIF) system has been developed to be an effective antibacterial surface discharge reactor for the diagnosis of RONS, where the highest spatial and temporal resolution of the LIF system has been achieved to ˜100 μm scale and ˜20 ns scale, respectively. Measurements on an oxidative OH radical have been carried out as typical RONS for the benchmark of the whole LIF system, where absolute number density calibration has been performed on the basis of the laser Rayleigh scattering method. Requirements for pixel resolved spatial distribution and outer plasma region detection become challenging tasks due to the low RONS concentration (˜ppb level) and strong interference, especially the discharge induced emission and pulsed laser induced stray light. In order to design the highly sensitive LIF system, a self-developed fluorescence telescope, the optimization of high precision synchronization among a tunable pulsed laser, a surface discharge generator, intensified Charge Coupled Device (iCCD) camera, and an oscilloscope have been performed. Moreover, an image BOXCAR approach has been developed to remarkably improve the sensitivity of the whole LIF system by optimizing spatial and temporal gating functions via both hardware and software, which has been integrated into our automatic control and data acquisition system on the LabVIEW platform. In addition, a reciprocation averaging measurement has been applied to verify the accuracy of the whole LIF detecting system, indicating the relative standard deviation of ˜3%.
NASA Astrophysics Data System (ADS)
Ike, Innocent S.; Sigalas, Iakovos; Iyuke, Sunny E.
2017-02-01
The effects of self-discharge on the performance of symmetric electric double-layer capacitors (EDLCs) and active electrolyte-enhanced supercapacitors were examined by incorporating self-discharge into electrochemical capacitor models during charging and discharging. The sources of self-discharge in capacitors were side reactions or redox reactions and several impurities and electric double-layer (EDL) instability. The effects of self-discharge during capacitor storage was negligible since it took a fully charged capacitor a minimum of 14.0 days to be entirely discharged by self-discharge in all conditions studied, hence self-discharge in storage condition can be ignored. The first and second charge-discharge cycle energy efficiencies η_{{{{E}}1}} and η_{{{{E}}2}} of a capacitor of electrode effective conductivity α1 = 0.05 S/cm with only EDL instability self-discharge with current density J_{{VR}} = 1.25 × 10-3 A/cm2 were 72.33% and 72.34%, respectively. Also, energy efficiencies η_{{{{E}}1}} and η_{{{{E}}2}} of a similar capacitor with both side reactions and redox reactions and EDL instability self-discharges with current densities J_{{VR}} = 0.00125 A/cm2 and J_{{{{VR}}1}} = 0.0032 A/cm2 were 38.13% and 38.14% respectively, compared with 84.24% and 84.25% in a similar capacitor without self-discharge. A capacitor with only EDL instability self-discharge and that with both side reactions and redox reactions and EDL instability self-discharge lost 9.73 Wh and 28.38 Wh of energy, respectively, through self-discharge during charging and discharging. Hence, EDLCs charging and discharging time is significantly dependent on the self-discharge rate which are too large to be ignored.
High Voltage Discharge Profile on Soil Breakdown Using Impulse Discharge
NASA Astrophysics Data System (ADS)
Fajingbesi, F. E.; Midi, N. S.; Elsheikh, E. M. A.; Yusoff, S. H.
2017-06-01
Grounding terminals are mandatory in electrical appliance design as they provide safety route during overvoltage faults. The soil (earth) been the universal ground is assumed to be at zero electric potential. However, due to properties like moisture, pH and available nutrients; the electric potential may fluctuate between positive and negative values that could be harmful for internally connected circuits on the grounding terminal. Fluctuations in soil properties may also lead to current crowding effect similar to those seen at the emitters of semiconductor transistors. In this work, soil samples are subjected to high impulse voltage discharge and the breakdown characteristics was profiled. The results from profiling discharge characteristics of soil in this work will contribute to the optimization of grounding protection system design in terms of electrode placement. This would also contribute to avoiding grounding electrode current crowding, ground potential rise fault and electromagnetic coupling faults.
Dalal, Anuj K; Schnipper, Jeffrey L; Poon, Eric G; Williams, Deborah H; Rossi-Roh, Kathleen; Macleay, Allison; Liang, Catherine L; Nolido, Nyryan; Budris, Jonas; Bates, David W; Roy, Christopher L
2012-01-01
Physicians are often unaware of the results of tests pending at discharge (TPADs). The authors designed and implemented an automated system to notify the responsible inpatient physician of the finalized results of TPADs using secure, network email. The system coordinates a series of electronic events triggered by the discharge time stamp and sends an email to the identified discharging attending physician once finalized results are available. A carbon copy is sent to the primary care physicians in order to facilitate communication and the subsequent transfer of responsibility. Logic was incorporated to suppress selected tests and to limit notification volume. The system was activated for patients with TPADs discharged by randomly selected inpatient-attending physicians during a 6-month pilot. They received approximately 1.6 email notifications per discharged patient with TPADs. Eighty-four per cent of inpatient-attending physicians receiving automated email notifications stated that they were satisfied with the system in a brief survey (59% survey response rate). Automated email notification is a useful strategy for managing results of TPADs.
NASA Astrophysics Data System (ADS)
Deal, Eric; Braun, Jean
2017-04-01
Climatic forcing undoubtedly plays an important role in shaping the Earth's surface. However, precisely how climate affects erosion rates, landscape morphology and the sedimentary record is highly debated. Recently there has been a focus on the influence of short-term variability in rainfall and river discharge on the relationship between climate and erosion rates. Here, we present a simple probabilistic argument, backed by modelling, that demonstrates that the way the Earth's surface responds to short-term climatic forcing variability is primarily determined by the existence and magnitude of erosional thresholds. We find that it is the ratio between the threshold magnitude and the mean magnitude of climatic forcing that determines whether variability matters or not and in which way. This is a fundamental result that applies regardless of the nature of the erosional process. This means, for example, that we can understand the role that discharge variability plays in determining fluvial erosion efficiency despite doubts about the processes involved in fluvial erosion. We can use this finding to reproduce the main conclusions of previous studies on the role of discharge variability in determining long-term fluvial erosion efficiency. Many aspects of the landscape known to influence discharge variability are affected by human activity, such as land use and river damming. Another important control on discharge variability, rainfall intensity, is also expected to increase with warmer temperatures. Among many other implications, our findings help provide a general framework to understand and predict the response of the Earth's surface to changes in mean and variability of rainfall and river discharge associated with the anthropogenic activity. In addition, the process independent nature of our findings suggest that previous work on river discharge variability and erosion thresholds can be applied to other erosional systems.
Xu, Wen-Tao; Peng, Hong-Jie; Huang, Jia-Qi; Zhao, Chen-Zi; Cheng, Xin-Bing; Zhang, Qiang
2015-09-07
The self-discharge of a lithium-sulfur cell decreases the shelf-life of the battery and is one of the bottlenecks that hinders its practical applications. New insights into both the internal chemical reactions in a lithium-sulfur system and effective routes to retard self-discharge for highly stable batteries are crucial for the design of lithium-sulfur cells. Herein, a lithium-sulfur cell with a carbon nanotube/sulfur cathode and lithium-metal anode in lithium bis(trifluoromethanesulfonyl)imide/1,3-dioxolane/dimethyl ether electrolyte was selected as the model system to investigate the self-discharge behavior. Both lithium anode passivation and polysulfide anion diffusion suppression strategies are applied to reduce self-discharge of the lithium-sulfur cell. When the lithium-metal anode is protected by a high density passivation layer induced by LiNO3 , a very low shuttle constant of 0.017 h(-1) is achieved. The diffusion of the polysulfides is retarded by an ion-selective separator, and the shuttle constants decreased. The cell with LiNO3 additive maintained a discharge capacity of 97 % (961 mAh g(-1) ) of the initial capacity after 120 days at open circuit, which was around three times higher than the routine cell (32 % of initial capacity, corresponding to 320 mAh g(-1) ). It is expected that lithium-sulfur batteries with ultralow self-discharge rates may be fabricated through a combination of anode passivation and polysulfide shuttle control, as well as optimization of the lithium-sulfur cell configuration. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Imaging motional Stark effect measurements at ASDEX Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ford, O. P.; Burckhart, A.; McDermott, R.
2016-11-15
This paper presents an overview of results from the Imaging Motional Stark Effect (IMSE) diagnostic obtained during its first measurement campaign at ASDEX Upgrade since installation as a permanent diagnostic. A brief overview of the IMSE technique is given, followed by measurements of a standard H-mode discharge, which are compared to equilibrium reconstructions showing good agreement where expected. The development of special discharges for the calibration of pitch angle is reported and safety factor profile changes during sawteeth crashes are shown, which can be resolved to a few percent due to the high sensitivity at good time resolution of themore » new IMSE system.« less
46 CFR 108.453 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 108.453 Section 108.453 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.453 Discharge...
46 CFR 108.453 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 108.453 Section 108.453 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.453 Discharge...
Johnson, K E; McMorris, B J; Raynor, L A; Monsen, K A
2013-01-01
The Omaha System is a standardized interface terminology that is used extensively by public health nurses in community settings to document interventions and client outcomes. Researchers using Omaha System data to analyze the effectiveness of interventions have typically calculated p-values to determine whether significant client changes occurred between admission and discharge. However, p-values are highly dependent on sample size, making it difficult to distinguish statistically significant changes from clinically meaningful changes. Effect sizes can help identify practical differences but have not yet been applied to Omaha System data. We compared p-values and effect sizes (Cohen's d) for mean differences between admission and discharge for 13 client problems documented in the electronic health records of 1,016 young low-income parents. Client problems were documented anywhere from 6 (Health Care Supervision) to 906 (Caretaking/parenting) times. On a scale from 1 to 5, the mean change needed to yield a large effect size (Cohen's d ≥ 0.80) was approximately 0.60 (range = 0.50 - 1.03) regardless of p-value or sample size (i.e., the number of times a client problem was documented in the electronic health record). Researchers using the Omaha System should report effect sizes to help readers determine which differences are practical and meaningful. Such disclosures will allow for increased recognition of effective interventions.
Corona discharge detection based on UV pulse method
NASA Astrophysics Data System (ADS)
Zhao, Taifei; Lei, Yangfei; Hou, Peng
2016-03-01
With the reforming and opening up, as well as the rapid economic development of china, the shortage of electricity resources in the eastern region has become a problem. Therefore, we have started the program of power transmission from west to east, and have speeding up the development of high-voltage transmission technologies with high efficiency, long-distance, and high-capacity. An important issue during the power transmission is the insulation design. Recently, there have been more and more power grid accidents are escalating. Therefore, timely discovering an forecasting insulation deteriorations using advance detection techniques is of special practical significance for the equipment maintenance and repairing , and especially avoiding power accidents. On this basis, this paper carries out the research of high-voltage transmission line corona discharge detection system using the solar blind and FPGA. The experimental result shows that our system can amplify week signals with different intensity of 5100 5000100 times, with high sensitivity and anti-interference ability. The result also proves that this system can effectively detect the ultraviolet pulse light signal of the corona discharge insulation.
NASA Astrophysics Data System (ADS)
Elfa, R. R.; Nafarizal, N.; Ahmad, M. K.; Sahdan, M. Z.; Soon, C. F.
2017-03-01
Atmospheric pressure plasma driven by Neon transformer power supply argon is presented in this paper. Atmospheric pressure plasma system has attracted researcher interest over low pressure plasma as it provides a flexibility process, cost-efficient, portable device and vacuum-free device. Besides, another golden key of this system is the wide promising application in the field of work cover from industrial and engineering to medical. However, there are still numbers of fundamental investigation that are necessary such as device configuration, gas configuration and its effect. Dielectric barrier discharge which is also known as atmospheric pressure plasma discharge is created when there is gas ionization process occur which enhance the movement of atom and electron and provide energetic particles. These energetic particles can provide modification and cleaning property to the sample surface due to the bombardment of the high reactive ion and radicals to the sample surface. In order to develop atmospheric pressure plasma discharge, a high voltage and high frequency power supply is needed. In this work, we used a neon transformer power supply as the power supply. The flow of the Ar is feed into 10 mm cylinder quartz tube with different treatment time in order to investigate the effect of the plasma discharge. The analysis of each treatment time is presented by optical emission spectroscopy (OES) and water contact angle (WCA) measurement. The increase of gas treatment time shows increases intensity of reactive Ar and reduces the angle of water droplets in water contact angle. Treatment time of 20 s microslide glass surface shows that the plasma needle discharges have modified the sample surface from hydrophilic surface to superhydrophilic surface. Thus, this leads to another interesting application in reducing sample surface adhesion to optimize productivity in the industry of paintings, semiconductor and more.
Shao, Hui; Mi, Ze; Ji, Wei-gang; Zhang, Cheng-huan; Zhang, Teng; Ren, Shuan-cheng; Zhu, Zhi-ru
2015-11-01
Accumulated soluble amyloid β (Aβ)-induced aberrant neuronal network activity has been recognized as a key causative factor leading to cognitive deficits which are the most outstanding characteristic of Alzheimer's disease (AD). As an important structure associated with learning and memory, the hippocampus is one of the brain regions that are impaired very early in AD, and the hippocampal CA1 region is selectively vulnerable to soluble Aβ oligomers. Our recent study showed that soluble Aβ1-42 oligomers induced hyperactivity and perturbed the firing patterns in hippocampal neurons. Rhynchophylline (RIN) is an important active tetracyclic oxindole alkaloid isolated from Uncaria rhynchophylla which is a traditional Chinese medicine and often used to treat central nervous system illnesses such as hypertension, convulsions, tremor, stroke etc. Previous evidence showed that RIN possessed neuroprotective effects of improving the cognitive function of mice with Alzheimer-like symptoms. In the present study, we aimed to investigate the protective effect of RIN against soluble Aβ1-42 oligomers-induced hippocampal hyperactivity. The results showed that (1) the mean frequency of spontaneous discharge was increased by the local application of 3 μM soluble Aβ1-42 oligomers; (2) 30 μM RIN did not exert any obvious effects on basal physiological discharges; and (3) treatment with RIN effectively inhibited the soluble Aβ1-42 oligomers-induced enhancement of spontaneous discharge, in a concentration-dependent manner with an IC50 = 9.0 μM. These in vivo electrophysiological results indicate that RIN can remold the spontaneous discharges disturbed by Aβ and counteract the deleterious effect of Aβ1-42 on neural circuit. The experimental findings provide further evidence to affirm the potential of RIN as a worthy candidate for further development into a therapeutic agent for AD.
Heat recovery system employing a temperature controlled variable speed fan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, W.T.
1986-05-20
A heat recovery system is described for use in recovering heat from an industrial process producing a heated fluid comprising: a source of inlet air; a housing coupled to the source and including a heat exchanger; means for passing the heated fluid through the heat exchanger; the housing including means for moving a variable volume of air adjustable over a continuous range from the source through the heat exchanger; air discharge means communicating with the housing for discharging air which has passed through the heat exchanger; a control system including first temperature sensing means for sensing the discharge temperature ofmore » the discharge air moving through the discharge means and a control circuit coupled to the first temperature sensing means and to the moving means for varying the volume of air moved in response to the sensed discharge temperature to control the temperature of discharge air passing through the discharge means at a first predetermined value; and the control system including second temperature sensing means for sensing the temperature of the source of inlet air and valve means coupled to and controlled by the control circuit to cause liquid to bypass the heat exchanger when the inlet air temperature rises above a second predetermined value.« less
High-speed imaging system for observation of discharge phenomena
NASA Astrophysics Data System (ADS)
Tanabe, R.; Kusano, H.; Ito, Y.
2008-11-01
A thin metal electrode tip instantly changes its shape into a sphere or a needlelike shape in a single electrical discharge of high current. These changes occur within several hundred microseconds. To observe these high-speed phenomena in a single discharge, an imaging system using a high-speed video camera and a high repetition rate pulse laser was constructed. A nanosecond laser, the wavelength of which was 532 nm, was used as the illuminating source of a newly developed high-speed video camera, HPV-1. The time resolution of our system was determined by the laser pulse width and was about 80 nanoseconds. The system can take one hundred pictures at 16- or 64-microsecond intervals in a single discharge event. A band-pass filter at 532 nm was placed in front of the camera to block the emission of the discharge arc at other wavelengths. Therefore, clear images of the electrode were recorded even during the discharge. If the laser was not used, only images of plasma during discharge and thermal radiation from the electrode after discharge were observed. These results demonstrate that the combination of a high repetition rate and a short pulse laser with a high speed video camera provides a unique and powerful method for high speed imaging.
Gafurov, M M; Aliev, A R; Ataev, M B; Rabadanov, K Sh
2013-10-01
The effects of high-voltage pulsed discharge (HVPD activation) on vibrational spectra of ion salt systems have been studied. The peculiarities of spectral display of HVPD in ion melts and aqueous solutions of electrolytes, in ion-conducting phases of crystalline and glassy salt systems have been investigated. After HVPD a salt system is in non-equilibrium activated state. In the activated state of a salt system, the relaxation time of the vibrational excited states of molecular ions is shorter than in the equilibrium state if the vibrational relaxation rate increases with temperature in the system. For those systems for which the relaxation rate decreases at elevated temperatures, the relaxation time of the vibrational excited states of molecular ions is longer than in the equilibrium state. HVPD activation of a salt system can change the configuration of the electron shell of molecular ions. Therefore, the lifetime values of activated state of salt systems are abnormally large. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Shao, Honglan; Xie, Feng; Liu, Chengyu; Liu, Zhihui; Zhang, Changxing; Yang, Gui; Wang, Jianyu
2016-04-01
The cooling water discharged from the coastal plants flow into the sea continuously, whose temperature is higher than original sea surface temperature (SST). The fact will have non-negligible influence on the marine environment in and around where the plants site. Hence, it's significant to monitor the temporal and spatial variation of the warm-water discharge for the assessment of the effect of the plant on its surrounding marine environment. The paper describes an approach for the dynamic monitoring of the warm-water discharge of coastal plants based on the airborne high-resolution thermal infrared remote sensing technology. Firstly, the geometric correction was carried out for the thermal infrared remote sensing images acquired on the aircraft. Secondly, the atmospheric correction method was used to retrieve the sea surface temperature of the images. Thirdly, the temperature-rising districts caused by the warm-water discharge were extracted. Lastly, the temporal and spatial variations of the warm-water discharge were analyzed through the geographic information system (GIS) technology. The approach was applied to Qinshan nuclear power plant (NPP), in Zhejiang Province, China. In considering with the tide states, the diffusion, distribution and temperature-rising values of the warm-water discharged from the plant were calculated and analyzed, which are useful to the marine environment assessment.
NASA Astrophysics Data System (ADS)
Tweed, Sarah O.; Leblanc, Marc; Webb, John A.; Lubczynski, Maciek W.
2007-02-01
Identifying groundwater recharge and discharge areas across catchments is critical for implementing effective strategies for salinity mitigation, surface-water and groundwater resource management, and ecosystem protection. In this study, a synergistic approach has been developed, which applies a combination of remote sensing and geographic information system (GIS) techniques to map groundwater recharge and discharge areas. This approach is applied to an unconfined basalt aquifer, in a salinity and drought prone region of southeastern Australia. The basalt aquifer covers ~11,500 km2 in an agriculturally intensive region. A review of local hydrogeological processes allowed a series of surface and subsurface indicators of groundwater recharge and discharge areas to be established. Various remote sensing and GIS techniques were then used to map these surface indicators including: terrain analysis, monitoring of vegetation activity, and mapping of infiltration capacity. All regions where groundwater is not discharging to the surface were considered potential recharge areas. This approach, applied systematically across a catchment, provides a framework for mapping recharge and discharge areas. A key component in assigning surface and subsurface indicators is the relevance to the dominant recharge and discharge processes occurring and the use of appropriate remote sensing and GIS techniques with the capacity to identify these processes.
NASA Astrophysics Data System (ADS)
Kimata, F.; Tasaka, S.; Asai, Y.
2016-12-01
Wariishi Spa is locating at Atotsugawa active fault, and it is an flowing spring from the 850m depth by the bore hole. The spring is coming from the rain fall through the geological boundary. Discharge was measured 100L/minute by manual every week in 1977. In 1990, measurement system was updated to 1Hz by electromagnetic flowmeter system. Co-seismic discharge rises are measured for about 100 examples of the earthquake occurrence in around area. The discharge rise is decreasing asymptotic convergence with time. In 2011 Tohoku Earthquake, the discharge of spring is a rise of 30 L/minutes, and it took 1 and half year to return to 20 L/minute. Ontake Volcano is one of the active volcanoes in same mountain range, but it is located about 50 km south from the Wariishi spa. There are three active volcanoes between Wariishi Spa and Ontake Volcano. The volcano was erupted in a phreatic explosion on September 27, 2014. There is no observation of the discharge change at the eruption in the hot spring. There are other hot spring systems in Wariishi spa. The spa has a periodic spring with one to two-hour frequencies. The periodic frequencies are depended on the discharge volume. Therefore, at the co-seismic discharge rise, the shortenings of periodic frequencies are observed. Hence, the mechanism of main discharge and periodic spring is located at the depth of 850 m. Based on discussion on time series of discharge spa, there are observed many pulsed noises between the periodic springs. The noises are caused by gas bubbling from the precise examinations. It is suggested that gas bubbling is different mechanism with periodic spring, because no effects on the periodic spring frequency. Bubbling is sourced from more deep than 850 m. Gas bubbling was observed about 50 times between the periodic spa around the Ontake volcano eruption. There is no report on such gas bubbling rise since 2012. Discussed above, it is suggested some changes of strain field at central Japan, especially in the mountain region before and after the 2014 Ontake volcano eruption. As result, gas bubbling was rise and Ontake volcano was erupted.
Armstrong, James; Forrest, Helen; Crawford, Mark W
2015-10-01
Discharge criteria based on physiological scoring systems can be used in the postanesthesia care unit (PACU) to fast-track patients after ambulatory surgery; however, studies comparing physiological scoring systems with traditional time-based discharge criteria are lacking. The purpose of this study was to compare PACU discharge readiness times using physiological vs time-based discharge criteria in pediatric ambulatory surgical patients. We recorded physiological observations from consecutive American Society of Anesthesiologists physical status I-III patients aged 1-18 yr who were admitted to the PACU after undergoing ambulatory surgery in a tertiary academic pediatric hospital. The physiological score was a combination of the Aldrete and Chung systems. Scores were recorded every 15 min starting upon arrival in the PACU. Patients were considered fit for discharge once they attained a score ≥12 (maximum score, 14), provided no score was zero, with the time to achieve a score ≥12 defining the criteria-based discharge (CBD) time. Patients were discharged from the PACU when both the CBD and the existing time-based discharge (TBD) criteria were met. The CBD and TBD data were compared using Kaplan-Meier and log-rank analysis. Observations from 506 children are presented. Median (interquartile range [IQR]) age was 5.5 [2.8-9.9] yr. Median [IQR] CBD and TBD PACU discharge readiness times were 30 [15-45] min and 60 [45-60] min, respectively. Analysis of Kaplan-Meier curves indicated a significant difference in discharge times using the different criteria (hazard ratio, 5.43; 95% confidence interval, 4.51 to 6.53; P < 0.001). All patients were discharged home without incident. This prospective study suggests that discharge decisions based on physiological criteria have the potential for significantly speeding the transit of children through the PACU, thereby enhancing PACU efficiency and resource utilization.
Effect of Discharge Summary Availability During Post-discharge Visits on Hospital Readmission
van Walraven, Carl; Seth, Ratika; Austin, Peter C; Laupacis, Andreas
2002-01-01
OBJECTIVE To determine if the delivery of hospital discharge summaries to follow-up physicians decreases the risk of hospital readmission. SUBJECTS Eight hundred eighty-eight patients discharged from a single hospital following treatment for an acute medical illness. SETTING Teaching hospital in a universal health-care system. DESIGN We determined the date that each patient's discharge summary was printed and the physicians to whom it was sent. Summary receipt was confirmed by survey and phoning each physician's office. Each patient's hospital chart was reviewed to determine their acute and chronic medical conditions as well as their course in hospital. Using population-based administrative databases, all post-hospitalization visits were identified. For each of these visits, we determined whether the summary was available. MAIN OUTCOME MEASURES Time to nonelective hospital readmission during 3 months following discharge. RESULTS The discharge summary was available for only 568 of 4,639 outpatient visits (12.2%). Overall, 240 (27.0%) of patients were urgently readmitted to hospital. After adjusting for significant patient and hospitalization factors, we found a trend toward a decreased risk of readmission for patients who were seen in follow-up by a physician who had received a summary (relative risk 0.74, 95% confidence interval 0.50 to 1.11). CONCLUSIONS The risk of rehospitalization may decrease when patients are assessed following discharge by physicians who have received the discharge summary. Further research is required to determine if better continuity of patient information improves patient outcomes. PMID:11929504
Self-learning control system for plug-in hybrid vehicles
DeVault, Robert C [Knoxville, TN
2010-12-14
A system is provided to instruct a plug-in hybrid electric vehicle how optimally to use electric propulsion from a rechargeable energy storage device to reach an electric recharging station, while maintaining as high a state of charge (SOC) as desired along the route prior to arriving at the recharging station at a minimum SOC. The system can include the step of calculating a straight-line distance and/or actual distance between an orientation point and the determined instant present location to determine when to initiate optimally a charge depleting phase. The system can limit extended driving on a deeply discharged rechargeable energy storage device and reduce the number of deep discharge cycles for the rechargeable energy storage device, thereby improving the effective lifetime of the rechargeable energy storage device. This "Just-in-Time strategy can be initiated automatically without operator input to accommodate the unsophisticated operator and without needing a navigation system/GPS input.
NASA Astrophysics Data System (ADS)
Zhou, Ming; Wu, Jianyang; Xu, Xiaoyi; Mu, Xin; Dou, Yunping
2018-02-01
In order to obtain improved electrical discharge machining (EDM) performance, we have dedicated more than a decade to correcting one essential EDM defect, the weak stability of the machining, by developing adaptive control systems. The instabilities of machining are mainly caused by complicated disturbances in discharging. To counteract the effects from the disturbances on machining, we theoretically developed three control laws from minimum variance (MV) control law to minimum variance and pole placements coupled (MVPPC) control law and then to a two-step-ahead prediction (TP) control law. Based on real-time estimation of EDM process model parameters and measured ratio of arcing pulses which is also called gap state, electrode discharging cycle was directly and adaptively tuned so that a stable machining could be achieved. To this end, we not only theoretically provide three proved control laws for a developed EDM adaptive control system, but also practically proved the TP control law to be the best in dealing with machining instability and machining efficiency though the MVPPC control law provided much better EDM performance than the MV control law. It was also shown that the TP control law also provided a burn free machining.
Oxidation of ammonium sulfite by a multi-needle-to-plate gas phase pulsed corona discharge reactor
NASA Astrophysics Data System (ADS)
Ren, Hua; Lu, Na; Shang, Kefeng; Li, Jie; Wu, Yan
2013-03-01
The oxidation of ammonium sulfite in the ammonia-based flue gas desulfurization (FGD) process was investigated in a multi-needle-to-plate gas phase pulsed corona discharge reactor in this paper. The effect of several parameters, including capacitance and peak pulse voltage of discharge system, electrode gap and bubbling gas flow rate on the oxidation rate of ammonium sulfite was reviewed. The oxidation rate of ammonium sulfite could reach 47.2% at the capacitance, the peak pulse voltage, electrode gap and bubbling gas flow rate equal to 2 nF, -24.6 k V, 35 mm and 4 L min-1 within treatment time of 40 min The experimental results indicate that the gas phase pulsed discharge system with a multi-needle-to-plate electrode can oxide the ammonium sulfite. The oxidation rate increased with the applied capacitance and peak pulse voltage and decreased with the electrode gap. As the bubbling gas flow rate increased, the oxidation rate increased first and then tended to reach a stationary value. These results would be important for the process optimization of the (NH4)2SO3 to (NH4)2SO4 oxidation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greig, A., E-mail: amelia.greig@anu.edu.au; Charles, C.; Boswell, R. W.
2016-01-15
Rovibrational spectroscopy band fitting of the nitrogen (N{sub 2}) second positive system is a technique used to estimate the neutral gas temperature of N{sub 2} discharges, or atomic discharges with trace amounts of a N{sub 2} added. For mixtures involving argon and N{sub 2}, resonant energy transfer between argon metastable atoms (Ar*) and N{sub 2} molecules may affect gas temperature estimates made using the second positive system. The effect of Ar* resonance energy transfer is investigated here by analyzing neutral gas temperatures of argon-N{sub 2} mixtures, for N{sub 2} percentages from 1% to 100%. Neutral gas temperature estimates are highermore » than expected for mixtures involving greater than 5% N{sub 2} addition, but are reasonable for argon with less than 5% N{sub 2} addition when compared with an analytic model for ion-neutral charge exchange collisional heating. Additional spatiotemporal investigations into neutral gas temperature estimates with 10% N{sub 2} addition demonstrate that although absolute temperature values may be affected by Ar* resonant energy transfer, spatiotemporal trends may still be used to accurately diagnose the discharge.« less
NASA Astrophysics Data System (ADS)
Choi, Kwangseok; Mogami, Tomofumi; Suzuki, Teruo
2014-04-01
To detect electrostatic discharges generated by polymer granules within a metal silo, we developed a novel and simple electrostatic discharge detector that utilizes a photosensor. The novel detector consists of a photosensor module in a metal cylinder, an optical band-pass filter, a quartz glass, a power supply, an amplifier for the photosensor module, and a digital oscilloscope. In this study, we conducted experiments at a real pneumatic powder transport facility that includes a metal silo to evaluate the novel detector using polypropylene granules. To determine the performance of the novel detector, we observed the electrostatic discharge within the metal silo using a conventional image intensifier system. The results obtained from the experiments show that the novel detector worked well in this study. The signals obtained with the novel detector were identical to the electrostatic discharges obtained with the conventional image intensifier system. The greatest advantage of this novel detector is that it is effective even when placed under external lights. In addition, the influence of various optical band-pass filters on the performance of the novel detector was discussed. Our study confirmed that an optical band-pass filter with a center wavelength of λ 330 nm (λ1/2: 315-345 nm) was the best performer among the optical band-pass filters used in this study.
Choi, Kwangseok; Mogami, Tomofumi; Suzuki, Teruo
2014-04-01
To detect electrostatic discharges generated by polymer granules within a metal silo, we developed a novel and simple electrostatic discharge detector that utilizes a photosensor. The novel detector consists of a photosensor module in a metal cylinder, an optical band-pass filter, a quartz glass, a power supply, an amplifier for the photosensor module, and a digital oscilloscope. In this study, we conducted experiments at a real pneumatic powder transport facility that includes a metal silo to evaluate the novel detector using polypropylene granules. To determine the performance of the novel detector, we observed the electrostatic discharge within the metal silo using a conventional image intensifier system. The results obtained from the experiments show that the novel detector worked well in this study. The signals obtained with the novel detector were identical to the electrostatic discharges obtained with the conventional image intensifier system. The greatest advantage of this novel detector is that it is effective even when placed under external lights. In addition, the influence of various optical band-pass filters on the performance of the novel detector was discussed. Our study confirmed that an optical band-pass filter with a center wavelength of λ 330 nm (λ1/2: 315-345 nm) was the best performer among the optical band-pass filters used in this study.
EPA NetDMR CROMERR System Checklist
The Network Disharge Monitoring Report (NetDMR) electronic reporting system is used for the receipt of discharge monitoring reports (DMRs) under the National Pollutant Discharge Elimination System (NPDES) program,
Non-Contact Thermal Characterization of NASA's HERMeS Hall Thruster
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Myers, James L.; Yim, John T.; Neff, Gregory
2015-01-01
The thermal characterization test of NASA's 12.5-kW Hall Effect Rocket with Magnetic Shielding has been completed. This thruster was developed to support a number of potential Solar Electric Propulsion Technology Demonstration Mission concepts, including the Asteroid Redirect Robotic Mission concept. As a part of the preparation for this characterization test, an infrared-based, non-contact thermal imaging system was developed to measure the temperature of various thruster surfaces that are exposed to high voltage or plasma. An in-situ calibration array was incorporated into the setup to improve the accuracy of the temperature measurement. The key design parameters for the calibration array were determined in a separate pilot test. The raw data from the characterization test was analyzed though further work is needed to obtain accurate anode temperatures. Examination of the front pole and discharge channel temperatures showed that the thruster temperature was driven more by discharge voltage than by discharge power. Operation at lower discharge voltages also yielded more uniform temperature distributions than at higher discharge voltages. When operating at high discharge voltage, increasing the magnetic field strength appeared to have made the thermal loading azimuthally more uniform.
Wolk, Adam; Wang, Erwin; Horak, Bernard; Cloonan, Patricia; Adams, Michael; Moore, Eileen; Jaipaul, Chitra Komal; Brown, Gabrielle; Dasgupta, Dabanjan; Deluca, Danielle; Grossman, Mila
2013-01-01
Evaluate the effect of a modest financial incentive on time-to-discharge summary dictation among medicine residents. Pay-for-performance incentives are used in a number of health care settings. Studies are lacking on their use with medical residents and other trainees. Timely completion of discharge summaries is necessary for effective follow-up after hospitalization, and residents perform the majority of discharge summary dictations in academic medical centers. Medicine residents with the lowest average discharge-to-dictation time during their 1-month inpatient medicine ward rotation were rewarded with a $50 gift card. Discharge data were captured using an autopopulating electronic database. The average discharge-to-dictation time was reduced from 7.44 to 1.84 days, representing a 75.3% decrease. Almost 90% of discharge summary dictations were performed on the day of discharge. A modest financial incentive resulted in a marked improvement in the time-to-discharge summary dictation by medicine residents. Pay-for-performance programs may be an effective strategy for improving the quality and efficiency of patient care in academic medical centers.
Kircher, J.E.
1981-01-01
Sediment discharge was computed for four locations along the North Platte, South Platte, and the Platte Rivers between North Platte and Grand Island, Nebraska in order to determine the effective discharge. The total-sediment discharge was computed by the Colby method and modified Einstein method so that comparisons could be made with the measured total-sediment discharge. The results agreed closely. The Colby method is the simplest and most convenient to use. The mean annual total-sediment discharge for the four sites investigated ranged from 150 tons per day for the South Platte River at North Platte to 1,260 tons per day for the Platte River near Grand Island. The effective discharge at the sites ranged from 41 to 158 cubic meters per second. The probability of the effective discharge being equaled or exceeded ranged from 1 to 30 percent for the four sites. (USGS)
[Environmental effects of combined sewage detention tank in central Shanghai].
Cheng, Jiang; Lü, Yong-peng; Huang, Xiao-fang; Guo, Sheng
2009-08-15
Through measuring the processes of precipitation, discharge and pollutant concentration over 20 times from 2006 to 2008 in Chendulu combined sewerage system (CSS) along Suzhou Creek in central Shanghai, the environmental effects of Chendulu combined sewage detention tank (CSDT), the first running CSDT in China, were studied. The results show that CSDT could improve CSS discharge capacity effectively with promoted interception ratio from 3.87 to 6.90-9.92. The mean annual combined sewer overflow (CSO) reduction and reduction rate are 9.10 x 10(4) m3 and 9.00%, respectively, and those of sanitary waste discharged directly to Suzhou Creek in non-rain-weather are 8.37 x 10(4) m(3) and 100% , respectively. The mean annual pollutants decrease rate of COD, BOD5, SS, NH4+ -N and TP of CSO are 13.76%, 19.69%, 15.29%, 18.24% and 15.10%, respectively, and those CSO pollutants decrease 41.21 t, 12.37 t, 50.10 t, 2.12 t and 0.29 t annually, respectively. The CSDT also could decrease sanitary waste discharged to Suzhou Creek totally, and those decreased pollutants are 20.75 t, 4.87 t, 14.90 t, 4.49 t and 0.30 t annually, respectively. The analysis shows that the CSDT design standard, running models and rainfall characteristics are the important influencing factors to realize the environmental effects of CSDT.
Church, P.E.; Armstrong, D.S.; Granato, G.E.; Stone, V.J.; Smith, K.P.; Provencher, P.L.
1996-01-01
Four test sites along a 7-mile section of Route 25 in southeastern Massachusetts, each representing a specific highway-drainage system, were instrumented to determine the effectiveness of the drainage systems in preventing contamination of ground water by road salt. One of the systems discharges highway runoff onsite through local drainpipes. The other systems use trunkline drainpipes through which runoff from highway surfaces, shoulders, and median strips is diverted and discharged into either a local stream or a coastal waterway. Route 25 was completed and opened to traffic in the summer of 1987. Road salt was first applied to the highway in the winter of 1987-88. The study area is on a thick outwash plain composed primarily of sand and gravel. Water-table depths range from 15 to 60 feet below land surface at the four test sites. Ground-water flow is in a general southerly direction, approximately perpendicular to the highway. Streamflow in the study area is controlled primarily by ground-water discharge. Background concentrations of dissolved chloride, sodium, and calcium-the primary constituents of road salt-are similar in ground water and surface water and range from 5 to 20, 5 to 10, and 1 to 5 milligrams per liter, respectively. Data-collection programs were developed for monitoring the application of road salt to the highway, the quantity of road-salt water entering the ground water, diverted through the highway-drainage systems, and entering a local stream. The Massachusetts Highway Department monitored road salt applied to the highway and reported these data to the U.S. Geological Survey. The U.S. Geological Survey designed and operated the ground-water, highway- drainage, and surface-water data-collection programs. A road-salt budget will be calculated for each test site so that the effectiveness of the different highway-drainage systems in preventing contamination of ground water by road salt can be determined.
Spatial Shifts in Tidal-Fluvial Environments
NASA Astrophysics Data System (ADS)
Dykstra, S. L.; Dzwonkowski, B.
2017-12-01
Fresh water discharge damps tidal propagation and increases the phase lag, which has important impacts on system-wide sediment transport process and ecological structure. Here, the role of discharge on spatial variability in the dynamics of tidal rivers is investigated in Mobile Bay and Delta, a microtidal diurnal system where discharge ranges multiple orders of magnitude. Long-term observations at 7 velocity stations and 20 water level stations, ranging over 260km along the system, were analyzed. Observations of the tidal extinguishing point in both velocity and water level were highly variable with significant shifts in location covering a distance over 140km. The velocity stations also allowed for measuring the extent of flood (i.e. point where tidal flow is arrested by discharge) shifting 100km. With increased discharge, flow characteristics at station locations can transition from an estuary (i.e. bidirectional tidal flow) to a tidal river to a traditional fluvial environment. This revealed systematic discharge induced damping and an increase in phase lag. Interestingly, before damping occurs, the tide amplifies ( 15%) seaward of the extent of flood. Another consistent pattern is the higher sensitivity of the velocity signal to discharge than water level. This causes the velocity to lag more and create progressive tides. In a microtidal diurnal system, the signal propagates further inland than a semidiurnal tide due to its lower frequency but is easily damped due to the small amplitude, creating large shifts. Previous research has focused on environments dominated by semidiurnal tides with similar magnitudes to discharge using water level observations. For example, the well studied Columbia and the St. Lawrence rivers have small shifts in their tidal extinguishing point O(10km) (Jay 2016, Matte 2014). These shifts are not large enough to observe process like discharge-induced amplification and damping at the same site like in the Mobile system, but they may indicate a decoupling of the water level and velocity signal by discharge. Throughout the world, shifts in tidal rivers are created by seasonal discharge patterns, but large storms can quickly disrupt a system and move it over 140km in a few days.
Water quality facility investigation : summary report.
DOT National Transportation Integrated Search
2006-12-01
The genesis for this research project was a desire to comply with the National Pollutant Discharge Elimination : System (NPDES) as cost effectively as possible. The construction of stormwater handling and treatment facilities is : costly because of t...
An evaluation of Dynamic TOPMODEL for low flow simulation
NASA Astrophysics Data System (ADS)
Coxon, G.; Freer, J. E.; Quinn, N.; Woods, R. A.; Wagener, T.; Howden, N. J. K.
2015-12-01
Hydrological models are essential tools for drought risk management, often providing input to water resource system models, aiding our understanding of low flow processes within catchments and providing low flow predictions. However, simulating low flows and droughts is challenging as hydrological systems often demonstrate threshold effects in connectivity, non-linear groundwater contributions and a greater influence of water resource system elements during low flow periods. These dynamic processes are typically not well represented in commonly used hydrological models due to data and model limitations. Furthermore, calibrated or behavioural models may not be effectively evaluated during more extreme drought periods. A better understanding of the processes that occur during low flows and how these are represented within models is thus required if we want to be able to provide robust and reliable predictions of future drought events. In this study, we assess the performance of dynamic TOPMODEL for low flow simulation. Dynamic TOPMODEL was applied to a number of UK catchments in the Thames region using time series of observed rainfall and potential evapotranspiration data that captured multiple historic droughts over a period of several years. The model performance was assessed against the observed discharge time series using a limits of acceptability framework, which included uncertainty in the discharge time series. We evaluate the models against multiple signatures of catchment low-flow behaviour and investigate differences in model performance between catchments, model diagnostics and for different low flow periods. We also considered the impact of surface water and groundwater abstractions and discharges on the observed discharge time series and how this affected the model evaluation. From analysing the model performance, we suggest future improvements to Dynamic TOPMODEL to improve the representation of low flow processes within the model structure.
Crystal structure and electrochemical characteristics of non-AB 5 type La-Ni system alloys
NASA Astrophysics Data System (ADS)
Shi, Siqi; Ouyang, Chuying; Lei, Minsheng
The La-Ni system compounds have been prepared by arc-melting method under Ar atmosphere. X-ray diffraction analysis reveals that the as-prepared alloys consist of different phases. The electrochemical properties, including activation, maximum discharge capacity, high rate chargeability (HRC), and high rate dischargeability (HRD) of these alloy electrodes have been studied through the charge-discharge recycle testing at different temperatures and charge (or discharge) currents. Among the La-Ni alloy electrodes studied, LaNi 2.28 alloy has the most excellent high rate charging performance, and La 2Ni 7 alloy exhibit the highest high rate dischargeability, while La 7Ni 3 alloy is capable of discharging at low temperature.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... Elimination System (NPDES) General Permit for Discharges From Concentrated Animal Feeding Operations (CAFOs... permit for discharges from eligible owners/operators of concentrated animal feeding operations (CAFOs... of the final permit, animal feeding operations that are defined as CAFOs or designated as CAFOs by...
Excel spreadsheet of National Pollutant Discharge Elimination System (NPDES) permits as of 4/2000 for the Albemarle-Pamlico Estuary watershed. Permitted flow is in millions of gallons per day. Discharge codes are:
1 Domestic - Municipal
2 Domestic - Industrial/Commercial
NASA Astrophysics Data System (ADS)
Nyssen, J.; Pontzeele, J.; Billi, P.
2011-05-01
SummaryThe European beaver ( Castor fiber) was recently reintroduced to Belgium, after an absence of more than 150 years; around 120 beaver dam systems have been established. In Europe, few studies consider the hydrological effects of those dams, and the spatial scale larger than that of one beaver pond system has not been addressed at all. This research focuses on the hydrological effects of a series of six beaver dams on the Chevral R., a second order tributary of the Ourthe Orientale R. in a forested area of the Ardennes. Thereby, also the Ourthe Orientale sub-basin itself was taken into account, being the area with probably the highest density of beaver dams in Belgium. The main research questions regarded: (1) the extent to which discharge peaks are reduced at the very location and well downstream of beaver dams and (2) the impact of the beaver dams on low flows. The first approach consisted of a temporal analysis of the Ourthe Orientale discharge and precipitation data for the periods 1978-2003 (before) and 2004-2009 (after the establishment of beaver dams in the sub-basin). The second study determined the in situ impact of the beaver dams: discharges were measured (September 2009-March 2010) upstream as well as downstream of the 0.52 ha beaver dam system on the Chevral river, and changes in water level within the system of six dams were monitored. Our findings indicate that there is a significant lowering of discharge peaks in the downstream river reaches due to the effect of the beaver dams. The temporal analysis of the Ourthe Orientale sub-basin shows an increase in the recurrence interval for major floods; for instance, the recurrence interval of a reference flood of 60 m 3 s -1 increased from 3.4 years to 5.6 years since the establishment of the beaver dams. At the scale of the Chevral beaver dams' site, we measured that the dams top off the peak flows, in addition delaying them by approximately 1 day. There are also increased low flows: Q355 (i.e. the discharge exceeded 355 days in a year) of the Ourthe Orientale was 0.6 (±0.15) m 3 s -1 before beaver dam installation and 0.88 (±0.52) m 3 s -1 thereafter. These findings agree with studies that suggest natural measures for flood control at the level of small mountain streams instead or in complement of building large anthropogenic constructions. Nevertheless, more studies are needed to assess the effectiveness of beaver dams in flood mitigation at the scale of sub-basins.
User's manual for computer program BASEPLOT
Sanders, Curtis L.
2002-01-01
The checking and reviewing of daily records of streamflow within the U.S. Geological Survey is traditionally accomplished by hand-plotting and mentally collating tables of data. The process is time consuming, difficult to standardize, and subject to errors in computation, data entry, and logic. In addition, the presentation of flow data on the internet requires more timely and accurate computation of daily flow records. BASEPLOT was developed for checking and review of primary streamflow records within the U.S. Geological Survey. Use of BASEPLOT enables users to (1) provide efficiencies during the record checking and review process, (2) improve quality control, (3) achieve uniformity of checking and review techniques of simple stage-discharge relations, and (4) provide a tool for teaching streamflow computation techniques. The BASEPLOT program produces tables of quality control checks and produces plots of rating curves and discharge measurements; variable shift (V-shift) diagrams; and V-shifts converted to stage-discharge plots, using data stored in the U.S. Geological Survey Automatic Data Processing System database. In addition, the program plots unit-value hydrographs that show unit-value stages, shifts, and datum corrections; input shifts, datum corrections, and effective dates; discharge measurements; effective dates for rating tables; and numeric quality control checks. Checklist/tutorial forms are provided for reviewers to ensure completeness of review and standardize the review process. The program was written for the U.S. Geological Survey SUN computer using the Statistical Analysis System (SAS) software produced by SAS Institute, Incorporated.
NASA Astrophysics Data System (ADS)
Gallin, Louis-Jonardan; Farges, Thomas; Marchiano, Régis; Coulouvrat, François; Defer, Eric; Rison, William; Schulz, Wolfgang; Nuret, Mathieu
2016-04-01
In the framework of the European Hydrological Cycle in the Mediterranean Experiment project, a field campaign devoted to the study of electrical activity during storms took place in the south of France in 2012. An acoustic station composed of four microphones and four microbarometers was deployed within the coverage of a Lightning Mapping Array network. On the 26 October 2012, a thunderstorm passed just over the acoustic station. Fifty-six natural thunder events, due to cloud-to-ground and intracloud flashes, were recorded. This paper studies the acoustic reconstruction, in the low frequency range from 1 to 40 Hz, of the recorded flashes and their comparison with detections from electromagnetic networks. Concurrent detections from the European Cooperation for Lightning Detection lightning location system were also used. Some case studies show clearly that acoustic signal from thunder comes from the return stroke but also from the horizontal discharges which occur inside the clouds. The huge amount of observation data leads to a statistical analysis of lightning discharges acoustically recorded. Especially, the distributions of altitudes of reconstructed acoustic detections are explored in detail. The impact of the distance to the source on these distributions is established. The capacity of the acoustic method to describe precisely the lower part of nearby cloud-to-ground discharges, where the Lightning Mapping Array network is not effective, is also highlighted.
Clancy, A N; Macrides, F; Singer, A G; Agosta, W C
1984-10-01
The importance of the vomeronasal (accessory olfactory) system for the copulatory responses of male hamsters to a high molecular weight fraction (HMF) of vaginal discharge was assessed in animals that had their vomeronasal organs (VNO) removed. These organs were extirpated bilaterally using an oral approach through the palate so as to eliminate the peripheral afferents to the accessory olfactory bulb (AOB) with minimal or no damage to the main olfactory system. The selective peripheral deafferentation procedure was verified by applying horseradish peroxidase intranasally following intraperitoneal injections of epinephrine to facilitate the vomeronasal pumping mechanism that draws fluids into the VNO. Heavy, bilateral anterograde labeling was evident in the olfactory nerve afferents within the main olfactory bulb of males that had their VNO removed and of animals that received sham surgery. Sham-operated males also had heavy, bilateral labeling in the vomeronasal nerve afferents within the AOB, whereas no such labeling occurred among animals with bilateral removal of the VNO. In sham-operated animals, both the HMF and the unfractionated discharge significantly increased the incidence of intromission attempts toward anesthetized males (surrogate females) whose hindquarters were scented with these stimuli. The unfractionated discharge also produced a significant elevation of overt copulatory behavior in males with selective peripheral deafferentation of the vomeronasal system, whereas the HMF did not facilitate copulatory behavior in these animals.(ABSTRACT TRUNCATED AT 250 WORDS)
Use of a Smartphone for Collecting Data on River Discharge and Communication of Flood Risk.
NASA Astrophysics Data System (ADS)
Pena-Haro, S.; Lüthi, B.; Philippe, T.
2015-12-01
Although many developed countries have well-established systems for river monitoring and flood early warning systems, the population affected in developing countries by flood events is unsettled. Even more, future climate development is likely to increase the intensity and frequency of extreme weather events and therefore bigger impacts on the population can be expected.There are different types of flood forecasting systems, some are based on hydrologic models fed with rainfall predictions and observed river levels. Flood hazard maps are also used to increase preparedness in case of an extreme event, however these maps are static since they do not incorporate daily changing conditions on river stages. However, and especially in developing countries, data on river stages are scarce. Some of the reasons are that traditional fixed monitoring systems do not scale in terms of costs, repair is difficult as well as operation and maintenance, in addition vandalism poses additional challenges. Therefore there is a need of cheaper and easy-to-use systems for collecting information on river stage and discharge. We have developed a mobile device application for determining the water stage and discharge of open-channels (e.g. rivers, artificial channels, irrigation furrows). Via image processing the water level and surface velocity are measured, combining this information with priori knowledge on the channel geometry the discharge is estimated. River stage and discharge measurement via smart phones provides a non-intrusive, accurate and cost-effective monitoring method. No permanent installations, which can be flooded away, are needed. The only requirement is that the field of view contains two reference markers with known scale and with known position relative to the channel geometry, therefore operation and maintenance costs are very low. The other advantage of using smartphones, is that the data collected can be immediately sent via SMS to a central database. This information can be easily gathered for its use within models and redistributed, using the same channels, among interested stakeholders and the community.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Pinero, Luis; Haag, Thomas; Huang, Wensheng; Ahern, Drew; Liang, Ray; Shilo, Vlad
2016-01-01
NASA's Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This paper presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation along with open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thruster's discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.
Timely diagnosis of dairy calf respiratory disease using a standardized scoring system.
McGuirk, Sheila M; Peek, Simon F
2014-12-01
Respiratory disease of young dairy calves is a significant cause of morbidity, mortality, economic loss, and animal welfare concern but there is no gold standard diagnostic test for antemortem diagnosis. Clinical signs typically used to make a diagnosis of respiratory disease of calves are fever, cough, ocular or nasal discharge, abnormal breathing, and auscultation of abnormal lung sounds. Unfortunately, routine screening of calves for respiratory disease on the farm is rarely performed and until more comprehensive, practical and affordable respiratory disease-screening tools such as accelerometers, pedometers, appetite monitors, feed consumption detection systems, remote temperature recording devices, radiant heat detectors, electronic stethoscopes, and thoracic ultrasound are validated, timely diagnosis of respiratory disease can be facilitated using a standardized scoring system. We have developed a scoring system that attributes severity scores to each of four clinical parameters; rectal temperature, cough, nasal discharge, ocular discharge or ear position. A total respiratory score of five points or higher (provided that at least two abnormal parameters are observed) can be used to distinguish affected from unaffected calves. This can be applied as a screening tool twice-weekly to identify pre-weaned calves with respiratory disease thereby facilitating early detection. Coupled with effective treatment protocols, this scoring system will reduce post-weaning pneumonia, chronic pneumonia, and otitis media.
Storck, Florian R; Schmidt, Carsten K; Wülser, Richard; Brauch, Heinz-Jürgen
2012-01-01
Drinking water is often produced from surface water by riverbank filtration (RBF) or artificial groundwater recharge (AGR). In this study, an AGR system was exemplarily investigated and results were compared with those of RBF systems, in which the effects of redox milieu, temperature and surface water discharge on the cleaning efficiency were evaluated. Besides bulk parameters such as DOC (dissolved organic carbon), organic trace pollutants including iodinated X-ray contrast media, personal care products, complexing agents, and pharmaceuticals were investigated. At all studied sites, levels of TOC (total organic carbon), DOC, AOX (adsorbable organic halides), SAC (spectral absorption coefficient at 254 nm), and turbidity were reduced significantly. DOC removal was stimulated at higher groundwater temperatures during AGR. Several substances were generally easily removable during both AGR and RBF, regardless of the site, season, discharge or redox regime. For some more refractory substances, however, removal efficiency turned out to be significantly influenced by redox conditions.
Rapid mortality of pest arthropods by direct exposure to a dielectric barrier discharge
NASA Astrophysics Data System (ADS)
Bures, Brian Lee
The spread of arthropods due to trade of agricultural commodities and travel of humans is a significant problem in many countries. Limiting the movement of pest species is commonly achieved by the use of chemical pesticides at quarantine facilities. One potential alternative to chemical pesticides is direct exposure of contaminated commodities to ambient pressure electrical discharges. The arthropods are directly exposed to a 5.0 cm helium discharge with power densities on the order of 60 mW/cm3. Direct measurement of chemical species and ambient gas temperature shows the DBD treatment remains effective when the chemically reactive species are suppressed by helium, and when the ambient gas temperature of the discharge is below 40°C. In addition to gas temperature measurements and chemical species identification, the electron temperature and electron density were measured using the neutral bremsstrahlung continuum technique. This study is the first successful implementation of the neutral bremsstrahlung continuum emission diagnostic to a barrier discharge. The primary advantages of the diagnostic for barrier discharges are the measurement is passive and the spatial resolution is only limited by the collimation of the light and the sensitivity of the detector. Although the electron temperature (1.0--1.5 eV) and electron density (˜108 cm-3) are modest, non-chemical dielectric barrier discharge (DBD) treatment of arthropods has proven effective in significantly reducing the population of some arthropods including human body lice, green peach aphids, and western flower thrips. However, the treatment was not universally effective on all arthropod species. German cockroaches and citrus mealy bugs showed substantial resistance to the treatment. The study has shown the treatment does not always induce instant mortality: however, the mortality increases over a 24 hr-period after treatment. Based upon visual observation and the time after treatment to reach maximum mortality, the mode of action is either direct damage to the nervous system or changes to the hydrocarbon layer that protects the arthropods from dehydration.
Point geospatial dataset representing locations of NPDES outfalls/dischargers for facilities which generally represent the site of the discharge. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from treated waste water that is discharged into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more dischargers. The location represents the discharge point of a discrete conveyance such as a pipe or man made ditch.
Nutrient discharge from China’s aquaculture industry and associated environmental impacts
NASA Astrophysics Data System (ADS)
Zhang, Ying; Bleeker, Albert; Liu, Junguo
2015-04-01
China’s aquaculture industry accounts for the largest share of the world’s fishery production, and provides a principal source of protein for the nation’s booming population. However, the environmental effects of the nutrient loadings produced by this industry have not been systematically studied or reviewed. Few quantitative estimates exist for nutrient discharge from aquaculture and the resultant nutrient enrichment in waters and sediments. In this paper, we evaluate nutrient discharge from aquacultural systems into aquatic ecosystems and the resulting nutrient enrichment of water and sediments, based on data from 330 cases in 51 peer-reviewed publications. Nitrogen use efficiency ranged from 11.7% to 27.7%, whereas phosphorus use efficiency ranged from 8.7% to 21.2%. In 2010, aquacultural nutrient discharges into Chinese aquatic ecosystems included 1044 Gg total nitrogen (184 Gg N from mariculture; 860 Gg N freshwater culture) and 173 Gg total phosphorus (22 Gg P from mariculture; 151 Gg P from freshwater culture). Water bodies and sediments showed high levels of nutrient enrichment, especially in closed pond systems. However, this does not mean that open aquacultural systems have smaller nutrient losses. Improvement of feed efficiency in cage systems and retention of nutrients in closed systems will therefore be necessary. Strategies to increase nutrient recycling, such as integrated multi-trophic aquaculture, and social measures, such as subsidies, should be increased in the future. We recommend the recycling of nutrients in water and sediments by hybrid agricultural-aquacultural systems and the adoption of nutrient use efficiency as an indicator at farm or regional level for the sustainable development of aquaculture; such indicators; together with water quality indicators, can be used to guide evaluations of technological, policy, and economic approaches to improve the sustainability of Chinese aquaculture.
Worthington, Thomas A; Brewer, Shannon K; Farless, Nicole; Grabowski, Timothy B; Gregory, Mark S
2014-01-01
Habitat fragmentation and flow regulation are significant factors related to the decline and extinction of freshwater biota. Pelagic-broadcast spawning cyprinids require moving water and some length of unfragmented stream to complete their life cycle. However, it is unknown how discharge and habitat features interact at multiple spatial scales to alter the transport of semi-buoyant fish eggs. Our objective was to assess the relationship between downstream drift of semi-buoyant egg surrogates (gellan beads) and discharge and habitat complexity. We quantified transport time of a known quantity of beads using 2-3 sampling devices at each of seven locations on the North Canadian and Canadian rivers. Transport time was assessed based on median capture time (time at which 50% of beads were captured) and sampling period (time period when 2.5% and 97.5% of beads were captured). Habitat complexity was assessed by calculating width∶depth ratios at each site, and several habitat metrics determined using analyses of aerial photographs. Median time of egg capture was negatively correlated to site discharge. The temporal extent of the sampling period at each site was negatively correlated to both site discharge and habitat-patch dispersion. Our results highlight the role of discharge in driving transport times, but also indicate that higher dispersion of habitat patches relates to increased retention of beads within the river. These results could be used to target restoration activities or prioritize water use to create and maintain habitat complexity within large, fragmented river systems.
Worthington, Thomas A.; Brewer, Shannon K.; Farless, Nicole; Grabowski, Timothy B.; Gregory, Mark S.
2014-01-01
Habitat fragmentation and flow regulation are significant factors related to the decline and extinction of freshwater biota. Pelagic-broadcast spawning cyprinids require moving water and some length of unfragmented stream to complete their life cycle. However, it is unknown how discharge and habitat features interact at multiple spatial scales to alter the transport of semi-buoyant fish eggs. Our objective was to assess the relationship between downstream drift of semi-buoyant egg surrogates (gellan beads) and discharge and habitat complexity. We quantified transport time of a known quantity of beads using 2–3 sampling devices at each of seven locations on the North Canadian and Canadian rivers. Transport time was assessed based on median capture time (time at which 50% of beads were captured) and sampling period (time period when 2.5% and 97.5% of beads were captured). Habitat complexity was assessed by calculating width:depth ratios at each site, and several habitat metrics determined using analyses of aerial photographs. Median time of egg capture was negatively correlated to site discharge. The temporal extent of the sampling period at each site was negatively correlated to both site discharge and habitat-patch dispersion. Our results highlight the role of discharge in driving transport times, but also indicate that higher dispersion of habitat patches relates to increased retention of beads within the river. These results could be used to target restoration activities or prioritize water use to create and maintain habitat complexity within large, fragmented river systems.
Plasma Discharges in Gas Bubbles in Liquid Water: Breakdown Mechanisms and Resultant Chemistry
NASA Astrophysics Data System (ADS)
Gucker, Sarah M. N.
The use of atmospheric pressure plasmas in gases and liquids for purification of liquids has been investigated by numerous researchers, and is highly attractive due to their strong potential as a disinfectant and sterilizer. However, the fundamental understanding of plasma production in liquid water is still limited. Despite the decades of study dedicated to electrical discharges in liquids, many physical aspects of liquids, such as the high inhomogeneity of liquids, complicate analyses. For example, the complex nonlinearities of the fluid have intricate effects on the electric field of the propagating streamer. Additionally, the liquid material itself can vaporize, leading to discontinuous liquid-vapor boundaries. Both can and do often lead to notable hydrodynamic effects. The chemistry of these high voltage discharges on liquid media can have circular effects, with the produced species having influence on future discharges. Two notable examples include an increase in liquid conductivity via charged species production, which affects the discharge. A second, more complicated scenario seen in some liquids (such as water) is the doubling or tripling of molecular density for a few molecule layers around a high voltage electrode. These complexities require technological advancements in optical diagnostics that have only recently come into being. This dissertation investigates several aspects of electrical discharges in gas bubbles in liquids. Two primary experimental configurations are investigated: the first allows for single bubble analysis through the use of an acoustic trap. Electrodes may be brought in around the bubble to allow for plasma formation without physically touching the bubble. The second experiment investigates the resulting liquid phase chemistry that is driven by the discharge. This is done through a dielectric barrier discharge with a central high voltage surrounded by a quartz discharge tube with a coil ground electrode on the outside. The plasma is created either through flowing gas around the high voltage electrode in the discharge tube or self-generated by the plasma as in the steam discharge. This second method allows for large scale processing of contaminated water and for bulk chemical and optical analysis. Breakdown mechanisms of attached and unattached gas bubbles in liquid water were investigated using the first device. The breakdown scaling relation between breakdown voltage, pressure and dimensions of the discharge was studied. A Paschen-like voltage dependence for air bubbles in liquid water was discovered. The results of high-speed photography suggest the physical charging of the bubble due to a high voltage pulse; this charging can be significant enough to produce rapid kinetic motion of the bubble about the electrode region as the applied electric field changes over a voltage pulse. Physical deformation of the bubble is observed. This charging can also prevent breakdown from occurring, necessitating higher applied voltages to overcome the phenomenon. This dissertation also examines the resulting chemistry from plasma interacting with the bubble-liquid system. Through the use of optical emission spectroscopy, plasma parameters such as electron density, gas temperature, and molecular species production and intensity are found to have a time-dependence over the ac voltage cycle. This dependence is also source gas type dependent. These dependencies afford effective control over plasma-driven decomposition. The effect of plasma-produced radicals on various wastewater simulants is studied. Various organic dyes, halogenated compounds, and algae water are decomposed and assessed. Toxicology studies with melanoma cells exposed to plasma-treated dye solutions are completed, demonstrating the non-cytotoxic quality of the decomposition process. Thirdly, this dissertation examines the steam plasma system, developed through this research to circumvent the acidification associated with gas-feed discharges. This steam plasma creates its own gas pocket via field emission. This steam plasma is shown to have strong decontamination properties, with residual effects lasting beyond two weeks that continue to decompose contaminants. Finally, a "two-dimensional bubble" was developed and demonstrated as a novel diagnostic device to study the gas-water interface, the reaction zone. This device is shown to provide convenient access to the reaction zone and decomposition of various wastewater simulants is investigated.
TRICARE revision to CHAMPUS DRG-based payment system, pricing of hospital claims. Final rule.
2014-05-21
This Final rule changes TRICARE's current regulatory provision for inpatient hospital claims priced under the DRG-based payment system. Claims are currently priced by using the rates and weights that are in effect on a beneficiary's date of admission. This Final rule changes that provision to price such claims by using the rates and weights that are in effect on a beneficiary's date of discharge.
Elkjær, Karina; Labouriau, Rodrigo; Ancker, Marie-Louise; Gustafsson, Hans; Callesen, Henrik
2013-12-01
A detailed study of 398,237 lactations of Danish Holstein dairy cows was undertaken. The objective was to investigate the information gained by evaluating vaginal discharge in cows from 5 to 19 days post-partum (p.p.) using an ordinal scale from 0 to 9. The study focused on the interval from calving to first insemination (CFI) and the non-return rate 56 days after first insemination (NR56), adjusted for the confounders milk production and body condition score (BCS). For the analyses, BCS was evaluated on the same day that the uterine score was made. Milk production was defined as test-day milk yield in the first month p.p. The study showed that the evaluation of vaginal discharge according to this score system permitted ranking of cows according to CFI and NR56, i.e. an increasing uterine score was associated with a significantly longer time from calving to first insemination and significantly reduced the probability of success of the first insemination. Reproductive success was already affected if the uterine score had reached 4 (i.e. before the discharge smelled abnormally). The negative effect on CFI and NR56 increased as the uterine score increased, which suggested that the uterine scoring system was a useful guide to dairy producers. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Johnson, D. A.; Reid, M. A.
1985-01-01
The Cr(III) complexes present in the acidified chromium solutions used in the iron-chromium redox energy storage system have been isolated and identified as Cr(H2O)6(3+) and Cr(H2O)5Cl(2+) by ion-exchange chromatography and visible spectrophotometry. The cell reactions during charge-discharge cycles have been followed by means of visible spectrophotometry. The spectral bands were resolved into component peaks and concentrations of the Cr(III) species calculated using Beer's law. During the charge mode, Cr(H2O)5Cl(2+) is reduced to Cr(H2O)5Cl(+), and during the discharge mode Cr(H2O)5Cl(+) is oxidized back to Cr(H2O)5Cl(2+). Electrode potential measurements also support this interpretation. Hysteresis effects in the charge-discharge curves can be explained by the slow attainment of equilibrium between Cr(H2O)6(3+) and Cr(H2O)5Cl(2+).
Blee, John; Roux, Ryan K; Gautreaux, Stefani; Sherer, Jeffrey T; Garey, Kevin W
2015-07-15
The effects of dispensing inhalers to patients with chronic obstructive pulmonary disease (COPD) on hospital discharge were evaluated. Data were collected in 2011-12 for patients with COPD who had hospital orders for the study inhalers (preintervention group) and after implementation of the multidose medication dispensing on discharge (MMDD) service (2013-14) (postintervention group). The primary objective of this study was to assess inhaler adherence and readmission rates before and after MMDD implementation. Adherence was defined as filling the discharge prescription for the multidose inhaler at a Harris Health pharmacy within three days of discharge or having at least seven days of medication left in an inhaler from a previous prescription that was filled or refilled before hospital admission. All patients in the postintervention group were considered adherent, since every patient was given the remainder of his or her multidose inhaler when discharged. Data from 620 patients (412 in the preintervention group, 208 in the postintervention group) were collected. During the preintervention time period, 88 of 412 patients were readmitted within 30 days compared with 18 of 208 patients during the postintervention period (p < 0.001). The intervention was associated with a significant reduction in 30-day readmissions (p = 0.0016) and 60-day readmissions (p = 0.0056). A targeted pharmacy program to provide COPD patients being discharged from the hospital with the multidose inhalers they had used during hospitalization was associated with improved medication adherence, as measured by prescription filling behavior, and reduced rates of 30- and 60-day hospital readmissions. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
48 CFR 3052.217-97 - Discharge of liens (USCG).
Code of Federal Regulations, 2010 CFR
2010-10-01
...) (a) The Contractor shall immediately discharge or cause to be discharged, any lien or right in rem of... materials furnished under this contract. (b) If any such lien or right in rem is not immediately discharged... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Discharge of liens (USCG...
Engineering and Design: Fire Protection for Helicopter Hangars
1997-10-15
B-5 4.5 ESFR Sprinkler Systems Design Requirements...Early Suppression Fast Response ( ESFR ) sprinklers operating at a minimum discharge pressure of 345 kPa (50 psi). 3.13.2 Conventional automatic sprinkler...using ESFR sprinklers. 4.1.3 Although foam-water sprinkler systems using AFFF generally provide optimum effectiveness in combating a combustible or
Jinadatha, Chetan; Villamaria, Frank C; Ganachari-Mallappa, Nagaraja; Brown, Donna S; Liao, I-Chia; Stock, Eileen M; Copeland, Laurel A; Zeber, John E
2015-04-01
Whereas pulsed xenon-based ultraviolet light no-touch disinfection systems are being increasingly used for room disinfection after patient discharge with manual cleaning, their effectiveness in the absence of manual disinfection has not been previously evaluated. Our study indicates that pulsed xenon-based ultraviolet light systems effectively reduce aerobic bacteria in the absence of manual disinfection. These data are important for hospitals planning to adopt this technology as adjunct to routine manual disinfection. Published by Elsevier Inc.
Aucott, W.R.; Meadows, R.S.; Patterson, G.G.
1987-01-01
Base flow was computed to estimate discharge from regional aquifers for six large streams in the upper Coastal Plain of South Carolina and parts of North Carolina and Georgia. Aquifers that sustain the base flow of both large and small streams are stratified into shallow and deep flow systems. Base-flow during dry conditions on main stems of large streams was assumed to be the discharge from the deep groundwater flow system. Six streams were analyzed: the Savannah, South and North Fork Edisto, Lynches, Pee Dee, and the Luber Rivers. Stream reaches in the Upper Coastal Plain were studied because of the relatively large aquifer discharge in these areas in comparison to the lower Coastal Plain. Estimates of discharge from the deep groundwater flow system to the six large streams averaged 1.8 cu ft/sec/mi of stream and 0.11 cu ft/sec/sq mi of surface drainage area. The estimates were made by subtracting all tributary inflows from the discharge gain between two gaging stations on a large stream during an extreme low-flow period. These estimates pertain only to flow in the deep groundwater flow system. Shallow flow systems and total base flow are > flow in the deep system. (USGS)
Tien, Der-Chi; Tseng, Kuo-Hsiung; Liao, Chih-Yu; Tsung, Tsing-Tshih
2008-10-01
Nanoscale techniques for silver production may assist the resurgence of the medical use of silver, especially given that pathogens are showing increasing resistance to antibiotics. Traditional chemical synthesis methods for colloidal silver (CS) may lead to the presence of toxic chemical species or chemical residues, which may inhibit the effectiveness of CS as an antibacterial agent. To counter these problems a spark discharge system (SDS) was used to fabricate a suspension of colloidal silver in deionized water with no added chemical surfactants. SDS-CS contains both metallic silver nanoparticles (Ag(0)) and ionic silver forms (Ag(+)). The antimicrobial affect of SDS-CS on Staphylococcus aureus was studied. The results show that CS solutions with an ionic silver concentration of 30 ppm or higher are strong enough to destroy S. aureus. In addition, it was found that a solution's antimicrobial potency is directly related to its level of silver ion concentration.
Colman, Steven M.; Keigwin, L.D.; Forester, R.M.
1994-01-01
Two episodes of meltwater influx from glacial Lake Agassiz are recorded as prominent sedimentologic, isotopic, magnetic, and faunal signatures in southern Lake Michigan profundal sediments. As a tributary to the main path of eastward Lake Agassiz flow, southern Lake Michigan recorded only the largest, catastrophic discharges. The distinctive Wilmette Bed, a massive gray mud that interrrupts laminated red glaciolacustrine clays, marks the first episode, which occurred near the beginning of the Younger Dryas cooling events. The associated discharge may have played a role in the inception or severity of the Younger Dryas event. An oxygen isotope excursion in biogenic carbonate and changes in ostracode assemblages mark the second episode, which appears to have had at least two pulses, dated by accelerator mass spectrometer 14C ages on biogenic carbonate at about 8.9 and 8.6 ka. The second episode occurred during the early Holocene peak in global meltwater discharge and apparently had little widespread climatic or oceanographic effect. The contrast between the effects associated with these two episodes of meltwater discharge emphasizes the complexity of the ice sheet-ocean-climate system. -Authors
Zhang, Yi; Zhou, Minghua; Hao, Xiaolong; Lei, Lecheng
2007-03-01
The effect of gas bubbling on the removal efficiency of 4-chlorophenol (4-CP) in aqueous solution has been investigated using a novel pulsed high voltage gas-liquid hybrid discharge reactor, which generates gas-phase discharge above the water surface simultaneously with the spark discharge directly in the liquid. The time for 100% of 4-CP degradation in the case of oxygen bubbling (7 min) was much shorter than that in the case of nitrogen bubbling (25 min) as plenty of hydrogen peroxide and ozone formed in oxygen atmosphere enhanced the removal efficiency of 4-CP. Except for the main similar intermediates (4-chlorocatechol, hydroquinone and 1,4-benzoquinone) produced in the both cases of oxygen and nitrogen bubbling, special intermediates (5-chloro-3-nitropyrocatechol, 4-chloro-2-nitrophenol, nitrate and nitrite ions) were produced in nitrogen atmosphere. The reaction pathway of 4-CP in the case of oxygen bubbling was oxygen/ozone attack on the radical hydroxylated derivatives of 4-CP. However, in the case of nitrogen bubbling, hydroxylation was the main reaction pathway with effect of N atom on degradation of 4-CP.
Risk Factors for Institutionalization After Traumatic Brain Injury Inpatient Rehabilitation.
Eum, Regina S; Brown, Allen W; Watanabe, Thomas K; Zasler, Nathan D; Goldstein, Richard; Seel, Ronald T; Roth, Elliot J; Zafonte, Ross D; Glenn, Mel B
To create a profile of individuals with traumatic brain injury (TBI) who received inpatient rehabilitation and were discharged to an institutional setting using characteristics measured at rehabilitation discharge. The Traumatic Brain Injury Model Systems National Database is a prospective, multicenter, longitudinal database for people with moderate to severe TBI. We analyzed data for participants enrolled from January 2002 to June 2012 who had lived in a private residence before TBI. This cross-sectional study used logistic regression analyses to identify sociodemographic factors, lengths of stay, and cognitive and physical functioning levels that differentiated patients discharged to institutional versus private settings. Older age, living alone before TBI, and lower levels of function at rehabilitation discharge (independence in locomotion, bladder management, comprehension, and social interaction) were significantly associated with higher institutionalization rates and provided the best models identifying factors associated with institutionalization. Institutionalization was also associated with decreased independence in bed-chair-wheelchair transfers and increased duration of posttraumatic amnesia. Individuals institutionalized after inpatient rehabilitation for TBI were older, lived alone before injury, had longer posttraumatic amnesia durations, and were less independent in specific functional characteristics. Research evaluating the effect of increasing postdischarge support and improving treatment effectiveness in these functional areas is recommended.
2015-12-01
salinity effect caused by the Amur River’s discharge into the Tatar Strait, and a one- month delay after maximum discharge in September. The research...discovered another low salinity effect through the Korea Strait in summer by the Changjiang River’s discharge into the East China Sea, which identified... effect caused by the Amur River’s discharge into the Tatar Strait, and a one-month delay after maximum discharge in September. The research discovered
1980-12-01
AFIT/GEO/EE/80D-1 I -’ SYSTEM OPTIMIZATION OF THE GLOW DISCHARGE OPTICAL SPECTROSCOPY TECHNIQUE USED FOR IMPURITY PROFILING OF ION IMPLANTED GALLIUM ...EE/80D-1 (\\) SYSTEM OPTIMIZATION OF THE GLOW DISCHARGE OPTICAL SPECTROSCOPY TECHNIQUE USED FOR IMPURITY PROFILING OF ION IMPLANTED GALLIUM ARSENIDE...semiconductors, specifically annealed and unan- nealed ion implanted gallium arsenide (GaAs). Methods to improve the sensitivity of the GDOS system have
Mabire, Cédric; Dwyer, Andrew; Garnier, Antoine; Pellet, Joanie
2018-04-01
To determine the effectiveness of nursing discharge planning interventions on health-related outcomes for older inpatients discharged home. Inadequate discharge planning for the ageing population poses significant challenges for health services. Effective discharge planning interventions have been examined in several studies, but little information is available on nursing interventions for older people. Despite the research published on the importance of discharge planning, the impact on patient's health outcomes still needs to be evaluated in practice. Systematic review and meta-analysis. A systematic search was undertaken across 13 databases to retrieve published and unpublished studies in English between 2000-2015. Critical appraisal, data extraction and meta-analysis followed the methodology of the Joanna Briggs Institute. Thirteen studies were included in the review, 2 of 13 were pilot studies and one had a pre-post design. Included studies involved 3,964 participants with a median age of 77 years. Nurse discharge planning did not significantly reduce hospital readmission or quality of life, except readmission was lower across studies conducted in the USA. The overall effect score for nurse discharge planning on length of stay was statistically significant and positive. Nursing discharge planning is a complex intervention and difficult to evaluate. Findings suggest that nursing discharge planning for older inpatients discharged home increases the length of stay yet neither reduces readmission rate nor improves quality of life. © 2017 John Wiley & Sons Ltd.
Carré, N; Uhry, Z; Velten, M; Trétarre, B; Schvartz, C; Molinié, F; Maarouf, N; Langlois, C; Grosclaude, P; Colonna, M
2006-09-01
Cancer registries have a complete recording of new cancer cases occurring among residents of a specific geographic area. In France, they cover only 13% of the population. For thyroid cancer, where incidence rate is highly variable according to the district conversely to mortality, national incidence estimates are not accurate. A nationwide database, such as hospital discharge system, could improve this estimate but its positive predictive value and sensibility should be evaluated. The positive predictive value and the sensitivity for thyroid cancer case ascertainment (ICD-10) of the national hospital discharge system in 1999 and 2000 were estimated using the cancer registries database of 10 French districts as gold standard. The linkage of the two databases required transmission of nominative information from the health facilities of the study. From the registries database, a logistic regression analysis was carried out to identify factors related to being missed by the hospital discharge system. Among the 973 standardized discharge charts selected from the hospital discharge system, 866 were considered as true positive cases, and 107 as false positive. Forty five of the latter group were prevalent cases. The predictive positive value was 89% (95% confidence interval (CI): 87-91%) and did not differ according to the district (p=0,80). According to the cancer registries, 322 thyroid cancer cases diagnosed in 1999 or 2000 were missed by the hospital discharge system. Thus, the sensitivity of this latter system was 73% (70-76%) and varied significantly from 62% to 85% across districts (p<0.001) and according to the type of health facility (p<0.01). Predictive positive value of the French hospital discharge system for ascertainment of thyroid cancer cases is high and stable across districts. Sensitivity is lower and varies significantly according to the type of health facility and across districts, which limits the interest of this database for a national estimate of thyroid cancer incidence rate.
Discharge Planning in Chronic Conditions
McMartin, K
2013-01-01
Background Chronically ill people experience frequent changes in health status accompanied by multiple transitions between care settings and care providers. Discharge planning provides support services, follow-up activities, and other interventions that span pre-hospital discharge to post-hospital settings. Objective To determine if discharge planning is effective at reducing health resource utilization and improving patient outcomes compared with standard care alone. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2004, until December 13, 2011. Review Methods Reports, randomized controlled trials, systematic reviews, and meta-analyses with 1 month or more of follow-up and limited to specified chronic conditions were examined. Outcomes included mortality/survival, readmissions and emergency department (ED) visits, hospital length of stay (LOS), health-related quality of life (HRQOL), and patient satisfaction. Results One meta-analysis compared individualized discharge planning to usual care and found a significant reduction in readmissions favouring individualized discharge planning. A second meta-analysis compared comprehensive discharge planning with postdischarge support to usual care. There was a significant reduction in readmissions favouring discharge planning with postdischarge support. However, there was significant statistical heterogeneity. For both meta-analyses there was a nonsignificant reduction in mortality between the study arms. Limitations There was difficulty in distinguishing the relative contribution of each element within the terms “discharge planning” and “postdischarge support.” For most studies, “usual care” was not explicitly described. Conclusions Compared with usual care, there was moderate quality evidence that individualized discharge planning is more effective at reducing readmissions or hospital LOS but not mortality, and very low quality evidence that it is more effective at improving HRQOL or patient satisfaction. Compared with usual care, there was low quality evidence that the discharge planning plus postdischarge support is more effective at reducing readmissions but not more effective at reducing hospital LOS or mortality. There was very low quality evidence that it is more effective at improving HRQOL or patient satisfaction. Plain Language Summary Chronically ill people experience frequent changes in their health status and multiple transitions between care settings and care providers (e.g., hospital to home). Discharge planning provides support services, follow-up activities and other interventions that span pre-hospital discharge to post-hospital settings. A review of the effects of different discharge plans was conducted. After searching for relevant studies, 11 studies were found that compared discharge planning with routine discharge care. This review indicates that: Individualized discharge planning reduces initial hospital length of stay and subsequent readmission to hospital but does not reduce mortality. The effect on health-related quality of life (HRQOL) or patient satisfaction is uncertain. Discharge planning plus postdischarge support reduces readmissions but does not reduce the initial hospital length of stay or mortality after discharge. The effect on HRQOL or patient satisfaction is uncertain. PMID:24167538
Extension of spatiotemporal chaos in glow discharge-semiconductor systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akhmet, Marat, E-mail: marat@metu.edu.tr; Fen, Mehmet Onur; Rafatov, Ismail
2014-12-15
Generation of chaos in response systems is discovered numerically through specially designed unidirectional coupling of two glow discharge-semiconductor systems. By utilizing the auxiliary system approach, [H. D. I. Abarbanel, N. F. Rulkov, and M. M. Sushchik, Phys. Rev. E 53, 4528–4535 (1996)] it is verified that the phenomenon is not a chaos synchronization. Simulations demonstrate various aspects of the chaos appearance in both drive and response systems. Chaotic control is through the external circuit equation and governs the electrical potential on the boundary. The expandability of the theory to collectives of glow discharge systems is discussed, and this increases themore » potential of applications of the results. Moreover, the research completes the previous discussion of the chaos appearance in a glow discharge-semiconductor system [D. D. Šijačić U. Ebert, and I. Rafatov, Phys. Rev. E 70, 056220 (2004).].« less
Extension of spatiotemporal chaos in glow discharge-semiconductor systems.
Akhmet, Marat; Rafatov, Ismail; Fen, Mehmet Onur
2014-12-01
Generation of chaos in response systems is discovered numerically through specially designed unidirectional coupling of two glow discharge-semiconductor systems. By utilizing the auxiliary system approach, [H. D. I. Abarbanel, N. F. Rulkov, and M. M. Sushchik, Phys. Rev. E 53, 4528-4535 (1996)] it is verified that the phenomenon is not a chaos synchronization. Simulations demonstrate various aspects of the chaos appearance in both drive and response systems. Chaotic control is through the external circuit equation and governs the electrical potential on the boundary. The expandability of the theory to collectives of glow discharge systems is discussed, and this increases the potential of applications of the results. Moreover, the research completes the previous discussion of the chaos appearance in a glow discharge-semiconductor system [D. D. Šijačić U. Ebert, and I. Rafatov, Phys. Rev. E 70, 056220 (2004).].
NASA Astrophysics Data System (ADS)
Chuang, K. Y.; Tishchenko, P. Y.; Gong, G. C.; Chou, W. C.; Tishchenko, P. P.; Shkirnikova, E. M.
2016-02-01
Continental shelves are active sites of air-sea CO2 exchange and represent an important component of the global carbon budget. In this study, we investigated the CO2 system and pertinent hydrographic parameters in two distinct continental shelf systems in the Northwest Pacific in summer 2014: the East China Sea shelf (ECSS) and the Peter the Great Bay (PGB) of the Japan/East Sea. The results show that the average temperature, pH, chlorophyll a and nutrients in the ECSS are higher, but salinity, dissolved inorganic carbon, and fugacity of CO2 are lower than those in the PGB. Meanwhile, the ECSS acted as a sink of atmospheric CO2, but the PGB was a source. We suggest that the observed divergent behaviors in terms of CO2 absorption between the ECSS and the PGB may be associated with their difference in riverine runoff. Under the influence of the Yangtze River, the nutrient discharge into the ECSS is much higher than that into the PGB, where only a few small rivers empty into. The high nutrient discharge into the ECSS may stimulate high biological production, which may drawdown CO2 and thereby driving the ECSS to act as a CO2 sink despite high temperature in summer. On the contrary, the warming effect may dominate over the effect of biological production in the PGB due to the limited nutrient discharge, and thus turn the PGB to be a source of atmospheric CO2. The results of this study imply that riverine nutrient discharge may exert a large control on net ecosystem productivity in shelf areas, which may subsequently play a critical role on determining whether a shelf system acts as a source or a sink of atmospheric CO2.
Muus, Kyle J; Knudson, Alana; Klug, Marilyn G; Gokun, Jane; Sarrazin, Mary; Kaboli, Peter
2010-01-01
Hospital re-admissions for patients with congestive heart failure (CHF) are relatively common and costly occurrences within the US health infrastructure, including the Veterans Affairs (VA) healthcare system. Little is known about CHF re-admissions among rural veteran patients, including the effects of socio-demographics and follow-up outpatient visits on these re-admissions. To examine socio-demographics of US veterans with CHF who had 30 day potentially preventable re-admissions and compare the effect of 30 day VA post-discharge service use on these re-admissions for rural- and urban-dwelling veterans. The 2005-2007 VA data were analyzed to examine patient characteristics and hospital admissions for 36 566 veterans with CHF. The CHF patients who were and were not re-admitted to a VA hospital within 30 days of discharge were identified. Logistic regression was used to examine and compare the effect of VA post-acute service use on re-admissions between rural- and urban-dwelling veterans. Re-admitted veterans tended to be older (p=.002), had disability status (p=.024) and had longer hospital stays (p<.001). Veterans Affairs follow-up visits were negatively associated with re-admissions for both rural and urban veterans with CHF (ORs 0.16-0.76). Rural veterans aged 65 years and older who had VA emergency room visits following discharge were at high risk for re-admission (OR=2.66). Post-acute follow-up care is an important factor for promoting recovery and good health among hospitalized veterans with CHF, regardless of their rural or urban residence. Older, rural veterans with CHF are in need of special attention for VA discharge planning and follow up with primary care providers.
Increased future ice discharge from Antarctica owing to higher snowfall.
Winkelmann, R; Levermann, A; Martin, M A; Frieler, K
2012-12-13
Anthropogenic climate change is likely to cause continuing global sea level rise, but some processes within the Earth system may mitigate the magnitude of the projected effect. Regional and global climate models simulate enhanced snowfall over Antarctica, which would provide a direct offset of the future contribution to global sea level rise from cryospheric mass loss and ocean expansion. Uncertainties exist in modelled snowfall, but even larger uncertainties exist in the potential changes of dynamic ice discharge from Antarctica and thus in the ultimate fate of the precipitation-deposited ice mass. Here we show that snowfall and discharge are not independent, but that future ice discharge will increase by up to three times as a result of additional snowfall under global warming. Our results, based on an ice-sheet model forced by climate simulations through to the end of 2500 (ref. 8), show that the enhanced discharge effect exceeds the effect of surface warming as well as that of basal ice-shelf melting, and is due to the difference in surface elevation change caused by snowfall on grounded versus floating ice. Although different underlying forcings drive ice loss from basal melting versus increased snowfall, similar ice dynamical processes are nonetheless at work in both; therefore results are relatively independent of the specific representation of the transition zone. In an ensemble of simulations designed to capture ice-physics uncertainty, the additional dynamic ice loss along the coastline compensates between 30 and 65 per cent of the ice gain due to enhanced snowfall over the entire continent. This results in a dynamic ice loss of up to 1.25 metres in the year 2500 for the strongest warming scenario. The reported effect thus strongly counters a potential negative contribution to global sea level by the Antarctic Ice Sheet.
Masterson, John P.; Pope, Jason P.; Monti, Jack; Nardi, Mark R.; Finkelstein, Jason S.; McCoy, Kurt J.
2013-11-14
Updates to the regional hydrologic budget include revised estimates of aquifer recharge, water use and streamflow data. Inflow to the aquifer system of about 20,000 million gallons per day (Mgal/d) includes 19,600 Mgal/d from recharge from precipitation, 200 Mgal/d of recharge from wastewater via onsite domestic septic systems, and 200 Mgal/d from the release of water from aquifer storage. Outflow from the aquifer system includes groundwater discharge to streams (11,900 Mgal/d), groundwater withdrawals (1,500 Mgal/d), and groundwater discharge to coastal waters (6,600 Mgal/d). A numerical modeling analysis is required to improve this hydrologic budget calculation and to forecast future changes in water levels and aquifer storage caused by groundwater withdrawals, land-use changes, and the effects of climate variability and change.
Hydrogen desorption using honeycomb finned heat exchangers integrated in adsorbent storage systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corgnale, Claudio; Hardy, Bruce; Chahine, Richard
One of the main technical hurdles associated with adsorbent based hydrogen storage systems is relative to their ability to discharge hydrogen effectively, as dictated by fuel cell requirements. In this study, a new honeycomb finned heat exchanger concept was examined to evaluate its potential as a heat transfer system for hydrogen desorption. A bench scale 0.5 L vessel was equipped with the proposed heat exchanger, filled with MOF-5® adsorbent material. The heating power, required to desorb hydrogen, was provided by a 100 W electric heater placed in the center of the honeycomb structure. Two desorption tests, at room temperature andmore » under cryogenic temperatures, were carried out to evaluate the hydrogen desorption performance of the proposed system under different operating conditions. The bench scale vessel performance was verified from both an experimental and a modeling point of view, demonstrating the ability to desorb about 45% of the adsorbed hydrogen in reduced time and applying low heating power. Further modeling analyses were also carried out showing the potential of the proposed system to reach high hydrogen discharging rates at cryogenic temperature conditions and operating pressures between 100 bar and 5 bar. The proposed adsorption system also demonstrated to be able to discharge all the available hydrogen in less than 500 s operating at cryogenic conditions and with a nominal heating power of 100 W.« less
Hydrogen desorption using honeycomb finned heat exchangers integrated in adsorbent storage systems
Corgnale, Claudio; Hardy, Bruce; Chahine, Richard; ...
2018-03-01
One of the main technical hurdles associated with adsorbent based hydrogen storage systems is relative to their ability to discharge hydrogen effectively, as dictated by fuel cell requirements. In this study, a new honeycomb finned heat exchanger concept was examined to evaluate its potential as a heat transfer system for hydrogen desorption. A bench scale 0.5 L vessel was equipped with the proposed heat exchanger, filled with MOF-5® adsorbent material. The heating power, required to desorb hydrogen, was provided by a 100 W electric heater placed in the center of the honeycomb structure. Two desorption tests, at room temperature andmore » under cryogenic temperatures, were carried out to evaluate the hydrogen desorption performance of the proposed system under different operating conditions. The bench scale vessel performance was verified from both an experimental and a modeling point of view, demonstrating the ability to desorb about 45% of the adsorbed hydrogen in reduced time and applying low heating power. Further modeling analyses were also carried out showing the potential of the proposed system to reach high hydrogen discharging rates at cryogenic temperature conditions and operating pressures between 100 bar and 5 bar. The proposed adsorption system also demonstrated to be able to discharge all the available hydrogen in less than 500 s operating at cryogenic conditions and with a nominal heating power of 100 W.« less
Cummins, Sharon; Zhu, Shu-Hong; Gamst, Anthony; Kirby, Carrie; Brandstein, Kendra; Klonoff-Cohen, Hillary; Chaplin, Edward; Morris, Timothy; Seymann, Gregory; Lee, Joshua
2012-08-01
Hospitalized smokers often quit smoking, voluntarily or involuntarily; most relapse soon after discharge. Extended follow-up counseling can help prevent relapse. However, it is difficult for hospitals to provide follow-up and smokers rarely leave the hospital with quitting aids (for example, nicotine patches). This study aims to test a practical model in which hospitals work with a state cessation quitline. Hospital staff briefly intervene with smokers at bedside and refer them to the quitline. Depending on assigned condition, smokers may receive nicotine patches at discharge or extended quitline telephone counseling post-discharge. This project establishes a practical model that lends itself to broader dissemination, while testing the effectiveness of the interventions in a rigorous randomized trial. This randomized clinical trial (N = 1,640) tests the effect of two interventions on long-term quit rates of hospitalized smokers in a 2 x 2 factorial design. The interventions are (1) nicotine patches (eight-week, step down program) dispensed at discharge and (2) proactive telephone counseling provided by the state quitline after discharge. Subjects are randomly assigned into: usual care, nicotine patches, telephone counseling, or both patches and counseling. It is hypothesized that patches and counseling have independent effects and their combined effect is greater than either alone. The primary outcome measure is thirty-day abstinence at six months; a secondary outcome is biochemically validated smoking status. Cost-effectiveness analysis is conducted to compare each intervention condition (patch alone, counseling alone, and combined interventions) against the usual care condition. Further, this study examines whether smokers' medical diagnosis is a moderator of treatment effect. Generalized linear (binomial) mixed models will be used to study the effect of treatment on abstinence rates. Clustering is accounted for with hospital-specific random effects. If this model is effective, quitlines across the U.S. could work with interested hospitals to set up similar systems. Hospital accreditation standards related to tobacco cessation performance measures require follow-up after discharge and provide additional incentive for hospitals to work with quitlines. The ubiquity of quitlines, combined with the consistency of quitline counseling delivery as centralized state operations, make this partnership attractive. Smoking cessation in hospitalized smokers NCT01289275. Date of registration February 1, 2011; date of first patient August 3, 2011.
Groene, Raluca Oana; Orrego, Carola; Suñol, Rosa; Barach, Paul; Groene, Oliver
2012-01-01
Background Handover practices at hospital discharge are relatively under-researched, particularly as regards the specific risks and additional requirements for handovers involving vulnerable patients with limited language, cognitive and social resources. Objective To explore handover practices at discharge and to focus on the patients’ role in handovers and on the potential additional risks for vulnerable patients. Methods We conducted qualitative interviews with patients, hospital professionals and primary care professionals in two hospitals and their associated primary care centres in Catalonia, Spain. Results We identified handover practices at discharge that potentially put patients at risk. Patients did not feel empowered in the handover but were expected to transfer information between care providers. Professionals identified lack of medication reconciliation at discharge, loss of discharge information, and absence of plans for follow-up care in the community as quality and safety problems for discharge handovers. These occurred for all patients, but appeared to be more frequent and have a greater negative effect in patients with limited language comprehension and/or lack of family and social support systems. Conclusions Discharge handovers are often haphazard. Healthcare professionals do not consider current handover practices safe, with patients expected to transfer information without being empowered to understand and act on it. This can lead to misinformation, omission or duplication of tests or interventions and, potentially, patient harm. Vulnerable patients may be at greater risk given their limited language, cognitive and social resources. Patient safety at discharge could benefit from strategies to enhance patient education and promote empowerment. PMID:23112285
Mehta, Rajnikant L; Baxendale, Bryn; Roth, Katie; Caswell, Victoria; Le Jeune, Ivan; Hawkins, Jack; Zedan, Haya; Avery, Anthony J
2017-09-05
Hospital discharge summaries are a key communication tool ensuring continuity of care between primary and secondary care. Incomplete or untimely communication of information increases risk of hospital readmission and associated complications. The aim of this study was to evaluate whether the introduction of a new electronic discharge system (NewEDS) was associated with improvements in the completeness and timeliness of discharge information, in Nottingham University Hospitals NHS Trust, England. A before and after longitudinal study design was used. Data were collected using the gold standard auditing tool from the Royal College of Physicians (RCP). This tool contains a checklist of 57 items grouped into seven categories, 28 of which are classified as mandatory by RCP. Percentage completeness (out of the 28 mandatory items) was considered to be the primary outcome measure. Data from 773 patients discharged directly from the acute medical unit over eight-week long time periods (four before and four after the change to the NewEDS) from August 2010 to May 2012 were extracted and evaluated. Results were summarised by effect size on completeness before and after changeover to NewEDS respectively. The primary outcome variable was represented with percentage of completeness score and a non-parametric technique was used to compare pre-NewEDS and post-NewEDS scores. The changeover to the NewEDS resulted in an increased completeness of discharge summaries from 60.7% to 75.0% (p < 0.001) and the proportion of summaries created under 24 h from discharge increased significantly from 78.0% to 93.0% (p < 0.001). Furthermore, five of the seven grouped checklist categories also showed significant improvements in levels of completeness (p < 0.001), although there were reduced levels of completeness for three items (p < 0.001). The introduction of a NewEDS was associated with a significant improvement in the completeness and timeliness of hospital discharge communication.
McMahon, P.B.; Lull, K.J.; Dennehy, K.F.; Collins, J.A.
1995-01-01
Water-quality studies conducted by the Metro Wastewater Reclamation District have indicated that during low flow in segments of the South Platte River between Denver and Fort Lupton, concentrations of dissolved oxygen are less than minimum concen- trations set by the State of Colorado. Low dissolved-oxygen concentrations are observed in two reaches of the river-they are about 3.3 to 6.4 miles and 17 to 25 miles downstream from the Metro Waste- water Reclamation District effluent outfalls. Concentrations of dissolved oxygen recover between these two reaches. Studies conducted by the U.S. Geological Survey have indicated that ground-water discharge to the river may contribute to these low dissolved-oxygen concentrations. As a result, an assessment was made of the quantity and quality of ground-water discharge to the South Platte River from Denver to Fort Lupton. Measurements of surface- water and ground-water discharge and collections of surface water and ground water for water-quality analyses were made from August 1992 through January 1993 and in May and July 1993. The quantity of ground-water discharge to the South Platte River was determined indirectly by mass balance of surface-water inflows and outflows and directly by instantaneous measurements of ground-water discharge across the sediment/water interface in the river channel. The quality of surface water and ground water was determined by sampling and analysis of water from the river and monitoring wells screened in the alluvial aquifer adjacent to the river and by sampling and analysis of water from piezometers screened in sediments underlying the river channel. The ground-water flow system was subdivided into a large-area and a small-area flow system. The precise boundaries of the two flow systems are not known. However, the large-area flow system is considered to incorporate all alluvial sediments in hydrologic connection with the South Platte River. The small- area flow system is considered to incorporate the alluvial aquifer in the vicinity of the river. Flow-path lengths in the large-area flow system were considered to be on the order of hundreds of feet to more than a mile, whereas in the small-area flow system, they were considered to be on the order of feet to hundreds of feet. Mass-balance estimates of incremental ground-water discharge from the large- area flow system ranged from -27 to 17 cubic feet per second per mile in three reaches of the river; the median rate was 4.6 cubic feet per second per mile. The median percentage of surface-water discharge derived from ground-water discharge in the river reaches studied was 13 percent. Instantaneous measurements of ground-water discharge from the small-area flow system ranged from -1,360 to 1,000 cubic feet per second per mile, with a median value of -5.8 cubic feet per second per mile. Hourly measurements of discharge from the small-area flow system indicated that the high rates of discharge were transient and may have been caused by daily fluctuations in river stage due to changing effluent-discharge rates from the Metro Wastewater Reclamation District treatment plant. Higher river stages caused surface water to infiltrate bed sediments underlying the river channel, and lower river stages allowed ground water to discharge into the river. Although stage changes apparently cycled large quantities of water in and out of the small- area flow system, the process probably provided no net gain or loss of water to the river. In general, mass balance and instantaneous measurements of ground-water discharge indicated that the ground- water flow system in the vicinity of the river consisted of a large-area flow system that provided a net addition of water to the river and a small- area flow system that cycled water in and out of the riverbed sediments, but provided no net addition of water to the river. The small-area flow system was superimposed on the large-area flow system. The median values of pH and dissolved oxygen
Lee, Den-Ching A; Williams, Cylie; Lalor, Aislinn F; Brown, Ted; Haines, Terry P
2018-05-09
High rates of unplanned hospital readmissions are a burden on healthcare systems and individuals. This study examined factors at, and after initial hospital discharge and their associations with unplanned hospital readmission for older adults up to six months post-discharge from subacute care. Older subacute care patients were surveyed prior to discharge, and assessed monthly post-discharge for six months. Data included the Geriatric Depression Scale, Phone-Fitt sub-scales, Friendship Scale, modified Lubben Social Network Scale, unplanned hospital readmission, self-reported physical capacity and falls in the last month were collected. Regression analyses were used to examine relationships between unplanned hospital readmission and variables that may predispose this outcome. Participants (n = 311) completed the baseline assessment. N = 218 (70%) completed all at six-month post-discharge. Eighty-nine (29%) participants shared 143 readmissions. Those with cancer history (adjusted OR [95% CI]) (1.97 [1.15, 3.39]), neurological disease other than stroke (2.95 [1.32, 6.57]) and dependence on others to assist in bending tasks (1.94 [1.14, 3.29]) at initial discharge were associated with readmission within six months post-discharge. Those who fell in the last month (adjusted OR [robust 95% CI]) (2.28 [1.43, 3.64]), being less physical active (0.98 [0.96, 0.99]), and dependence on others in moving around residence (2.63 [1.37, 5.06]) after initial discharge were associated with a readmission in the next month within six months post-discharge. Trials investigating the effectiveness of strategies to reduce falls, build physical capacity, increase physical activity level, and connection with health care services after discharge to prevent readmission are warranted. Copyright © 2018 Elsevier B.V. All rights reserved.
Effective Discharge and Annual Sediment Yield on Brazos River
NASA Astrophysics Data System (ADS)
Rouhnia, M.; Salehi, M.; Keyvani, A.; Ma, F.; Strom, K. B.; Raphelt, N.
2012-12-01
Geometry of an alluvial river alters dynamically over the time due to the sediment mobilization on the banks and bottom of the river channel in various flow rates. Many researchers tried to define a single representative discharge for these morphological processes such as "bank-full discharge", "effective discharge" and "channel forming discharge". Effective discharge is the flow rate in which, the most sediment load is being carried by water, in a long term period. This project is aimed to develop effective discharge estimates for six gaging stations along the Brazos River from Waco, TX to Rosharon, TX. The project was performed with cooperation of the In-stream Flow Team of the Texas Water Development Board (TWDB). Project objectives are listed as: 1) developing "Flow Duration Curves" for six stations based on mean-daily discharge by downloading the required, additional data from U.S Geological Survey website, 2) developing "Rating Curves" for six gaging stations after sampling and field measurements in three different flow conditions, 3) developing a smooth shaped "Sediment Yield Histogram" with a well distinguished peak as effective discharge. The effective discharge was calculated using two methods of manually and automatic bin selection. The automatic method is based on kernel density approximation. Cross-sectional geometry measurements, particle size distributions and water field samples were processed in the laboratory to obtain the suspended sediment concentration associated with flow rate. Rating curves showed acceptable trends, as the greater flow rate we experienced, the more sediment were carried by water.
Suffoletto, Brian; Lynch, Michael; Pacella, Charissa B; Yealy, Donald M; Callaway, Clifton W
2018-04-01
Prescription drug monitoring programs (PDMPs) enable registered prescribers to obtain real-time information on patients' prescription history of controlled medications. We sought to describe the effect of a state-mandated PDMP on opioid prescribing by emergency medicine providers. We retrospectively analyzed electronic medical records of 122,732 adult patients discharged with an opioid prescription from 15 emergency departments in a single health system in Pennsylvania from July 2015 to March, 2017. We used an interrupted time series design to evaluate the percentage of patients discharged each month with an opioid prescription before and after state law-mandated PDMP use on August 25, 2016. From August (pre-PDMP) to September, 2016 (post-PDMP), the opioid prescribing rate decreased from 12.4% (95% confidence interval [CI], 10.8%-14.1%) to 10.2% (95% CI, 8.8%-11.8%). For each month between September 2016 to March 2017, there was a mean decline of .46% (95% CI, -.38% to -.53%) in the percentage of patients discharged with an opioid prescription. There was heterogeneity in opioid prescribing across hospitals as well as according to patient diagnosis. This study examined the effect of a state-mandated PDMP on opioid prescribing among emergency medicine providers from 15 different hospitals in a single health system. Findings support current PDMP mandates in reducing opioid prescriptions, which could curb the prescription opioid epidemic and may ultimately reduce abuse, misuse, and overdose death. Copyright © 2017 The American Pain Society. Published by Elsevier Inc. All rights reserved.
Increased future ice discharge from Antarctica owing to higher snowfall
NASA Astrophysics Data System (ADS)
Winkelmann, Ricarda; Levermann, Anders; Martin, Maria A.; Frieler, Katja
2013-04-01
Anthropogenic climate change is likely to cause continuing global sea-level rise, but some processes within the Earth system may mitigate the magnitude of the projected effect. Regional and global climate models simulate enhanced snowfall over Antarctica, which would provide a direct offset of the future contribution to global sea level rise from cryospheric mass loss and ocean expansion. Uncertainties exist in modelled snowfall, but even larger uncertainties exist in the potential changes of dynamic ice discharge from Antarctica. Here we show that snowfall and discharge are not independent, but that future ice discharge will increase by up to three times as a result of additional snowfall under global warming. Our results, based on an ice-sheet model forced by climate simulations through to the end of 2500, show that the enhanced discharge effect exceeds the effect of surface warming as well as that of basal ice-shelf melting, and is due to the difference in surface elevation change caused by snowfall on grounded versus floating ice. Although different underlying forcings drive ice loss from basal melting versus increased snowfall, similar ice dynamical processes are nonetheless at work in both; therefore results are relatively independent of the specific representation of the transition zone. In an ensemble of simulations designed to capture ice-physics uncertainty, the additional dynamic ice loss along the coastline compensates between 30 and 65 per cent of the ice gain due to enhanced snowfall over the entire continent. This results in a dynamic ice loss of up to 1.25 metres in the year 2500 for the strongest warming scenario.
Modeling of non-thermal plasma in flammable gas mixtures
NASA Astrophysics Data System (ADS)
Napartovich, A. P.; Kochetov, I. V.; Leonov, S. B.
2008-07-01
An idea of using plasma-assisted methods of fuel ignition is based on non-equilibrium generation of chemically active species that speed up the combustion process. It is believed that gain in energy consumed for combustion acceleration by plasmas is due to the non-equilibrium nature of discharge plasma, which allows radicals to be produced in an above-equilibrium amount. Evidently, the size of the effect is strongly dependent on the initial temperature, pressure, and composition of the mixture. Of particular interest is comparison between thermal ignition of a fuel-air mixture and non-thermal plasma initiation of the combustion. Mechanisms of thermal ignition in various fuel-air mixtures have been studied for years, and a number of different mechanisms are known providing an agreement with experiments at various conditions. The problem is -- how to conform thermal chemistry approach to essentially non-equilibrium plasma description. The electric discharge produces much above-equilibrium amounts of chemically active species: atoms, radicals and ions. The point is that despite excess concentrations of a number of species, total concentration of these species is far below concentrations of the initial gas mixture. Therefore, rate coefficients for reactions of these discharge produced species with other gas mixture components are well known quantities controlled by the translational temperature, which can be calculated from the energy balance equation taking into account numerous processes initiated by plasma. A numerical model was developed combining traditional approach of thermal combustion chemistry with advanced description of the plasma kinetics based on solution of electron Boltzmann equation. This approach allows us to describe self-consistently strongly non-equilibrium electric discharge in chemically unstable (ignited) gas. Equations of pseudo-one-dimensional gas dynamics were solved in parallel with a system of thermal chemistry equations, kinetic equations for charged particles (electrons, positive and negative ions), and with the electric circuit equation. The electric circuit comprises power supply, ballast resistor connected in series with the discharge and capacity. Rate coefficients for electron-assisted reactions were calculated from solving the two-term spherical harmonic expansion of the Boltzmann equation. Such an approach allows us to describe influence of thermal chemistry reactions (burning) on the discharge characteristics. Results of comparison between the discharge and thermal ignition effects for mixtures of hydrogen or ethylene with dry air will be reported. Effects of acceleration of ignition by discharge plasma will be analyzed. In particular, the role of singlet oxygen produced effectively in the discharge in ignition speeding up will be discussed.
Plasma discharge self-cleaning filtration system
Cho, Young I.; Fridman, Alexander; Gutsol, Alexander F.; Yang, Yong
2014-07-22
The present invention is directed to a novel method for cleaning a filter surface using a plasma discharge self-cleaning filtration system. The method involves utilizing plasma discharges to induce short electric pulses of nanoseconds duration at high voltages. These electrical pulses generate strong Shockwaves that disintegrate and dislodge particulate matter located on the surface of the filter.
Halford, Keith J.; Plume, Russell W.
2011-01-01
Assessing hydrologic effects of developing groundwater supplies in Snake Valley required numerical, groundwater-flow models to estimate the timing and magnitude of capture from streams, springs, wetlands, and phreatophytes. Estimating general water-table decline also required groundwater simulation. The hydraulic conductivity of basin fill and transmissivity of basement-rock distributions in Spring and Snake Valleys were refined by calibrating a steady state, three-dimensional, MODFLOW model of the carbonate-rock province to predevelopment conditions. Hydraulic properties and boundary conditions were defined primarily from the Regional Aquifer-System Analysis (RASA) model except in Spring and Snake Valleys. This locally refined model was referred to as the Great Basin National Park calibration (GBNP-C) model. Groundwater discharges from phreatophyte areas and springs in Spring and Snake Valleys were simulated as specified discharges in the GBNP-C model. These discharges equaled mapped rates and measured discharges, respectively. Recharge, hydraulic conductivity, and transmissivity were distributed throughout Spring and Snake Valleys with pilot points and interpolated to model cells with kriging in geologically similar areas. Transmissivity of the basement rocks was estimated because thickness is correlated poorly with transmissivity. Transmissivity estimates were constrained by aquifer-test results in basin-fill and carbonate-rock aquifers. Recharge, hydraulic conductivity, and transmissivity distributions of the GBNP-C model were estimated by minimizing a weighted composite, sum-of-squares objective function that included measurement and Tikhonov regularization observations. Tikhonov regularization observations were equations that defined preferred relations between the pilot points. Measured water levels, water levels that were simulated with RASA, depth-to-water beneath distributed groundwater and spring discharges, land-surface altitudes, spring discharge at Fish Springs, and changes in discharge on selected creek reaches were measurement observations. The effects of uncertain distributed groundwater-discharge estimates in Spring and Snake Valleys on transmissivity estimates were bounded with alternative models. Annual distributed groundwater discharges from Spring and Snake Valleys in the alternative models totaled 151,000 and 227,000 acre-feet, respectively and represented 20 percent differences from the 187,000 acre-feet per year that discharges from the GBNP-C model. Transmissivity estimates in the basin fill between Baker and Big Springs changed less than 50 percent between the two alternative models. Potential effects of pumping from Snake Valley were estimated with the Great Basin National Park predictive (GBNP-P) model, which is a transient groundwater-flow model. The hydraulic conductivity of basin fill and transmissivity of basement rock were the GBNP-C model distributions. Specific yields were defined from aquifer tests. Captures of distributed groundwater and spring discharges were simulated in the GBNP-P model using a combination of well and drain packages in MODFLOW. Simulated groundwater captures could not exceed measured groundwater-discharge rates. Four groundwater-development scenarios were investigated where total annual withdrawals ranged from 10,000 to 50,000 acre-feet during a 200-year pumping period. Four additional scenarios also were simulated that added the effects of existing pumping in Snake Valley. Potential groundwater pumping locations were limited to nine proposed points of diversion. Results are presented as maps of groundwater capture and drawdown, time series of drawdowns and discharges from selected wells, and time series of discharge reductions from selected springs and control volumes. Simulated drawdown propagation was attenuated where groundwater discharge could be captured. General patterns of groundwater capture and water-table declines were similar for all scenarios. Simulated drawdowns greater than 1 ft propagated outside of Spring and Snake Valleys after 200 years of pumping in all scenarios.
NASA Astrophysics Data System (ADS)
Wu, Yishan; Li, Jun; Ye, Jianchun; Chen, Xiaohong; Li, Huili; Huang, Sumei; Zhao, Ran; Ou-Yang, Wei
2017-10-01
Corona discharge-induced wind (CDIW) has been widely utilized in production lines in the food and semiconductor industries and in indoor devices such as electrostatic precipitators. Some ozone is inevitably emitted, posing serious health risks to respiratory system and lung function of a human being. In this work, a greener corona discharge with enhanced wind generation for a needle-to-cylinder discharge structure is demonstrated using a simple dip-coating method to attach carbon nanotubes (CNTs) to the discharge electrode of a stainless steel needle. Compared with a conventional discharge electrode without CNT decoration, the velocity of the CDIW is greatly enhanced, the onset voltage is lowered, the energy conversion efficiency is greatly improved and the concentration of generated ozone is much reduced, making this easy method of CNT decoration a promising candidate for greener corona discharge systems. In addition, several impact factors for improved performance are discussed mathematically and phenomenologically, providing an insight into the corona discharge and wind generation.
Charged Particle Environments in Earth's Magnetosphere and their Effects on Space System
NASA Technical Reports Server (NTRS)
Minow, Joseph I.
2009-01-01
This slide presentation reviews information on space radiation environments important to magnetospheric missions including trapped radiation, solar particle events, cosmic rays, and solar winds. It also includes information about ion penetration of the magnetosphere, galactic cosmic rays, solar particle environments, CRRES internal discharge monitor, surface charging and radiation effects.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
..., pesticides will not pose unreasonable risks to human health and the environment. All new pesticides must... human health and environmental effects associated with use of the product. Under FIFRA, EPA is required... health and environmental effects and exposures. The applicant for registration of the pesticide must...
The National Pollutant Discharge Elimination System (NPDES) stormwater program regulates some stormwater discharges from three potential sources: municipal separate storm sewer systems (MS4s), construction activities, and industrial activities.
de Jesus, Isac Silva; Ferreira, Milena; Silva-Júnior, Urbano Lopes; Alves-Gomes, José Antônio
2017-12-01
Considering the conserved nature of synaptic physiology among vertebrates, we tested the effects of three psychotropics (diazepam, doxapram, and nicotine) on Microsternarchus cf. bilineatus, measuring 10 parameters associated to the electric organ discharges rhythm and waveform before and after the administration of each drug and a control group. There were statistically significant differences (p < 0.005) among all the experimental groups, F (70, 22619.25) = 77.7, between the two experimental phases within their respective drug treatment, F (80, 24604.51) = 16.0, and among the six experimental hours within their respective phases and groups, F (320, 37124.15) = 4.1. We observed a common general trend of reduction in the electric organ's (EO) firing rate, regardless of the expected stimulant or depressor effect of the drugs on the central nervous system (CNS). The intensity of the response changed with the treatment. The observed changes in the fishes' behavior may be a result of the drugs' direct action on the CNS or a combination of this with systemic effects of each substance tested, also in the EO.
Equalizer system and method for series connected energy storing devices
Rouillard, Jean; Comte, Christophe; Hagen, Ronald A.; Knudson, Orlin B.; Morin, Andre; Ross, Guy
1999-01-01
An apparatus and method for regulating the charge voltage of a number of electrochemical cells connected in series is disclosed. Equalization circuitry is provided to control the amount of charge current supplied to individual electrochemical cells included within the series string of electrochemical cells without interrupting the flow of charge current through the series string. The equalization circuitry balances the potential of each of the electrochemical cells to within a pre-determined voltage setpoint tolerance during charging, and, if necessary, prior to initiating charging. Equalization of cell potentials may be effected toward the end of a charge cycle or throughout the charge cycle. Overcharge protection is also provided for each of the electrochemical cells coupled to the series connection. During a discharge mode of operation in accordance with one embodiment, the equalization circuitry is substantially non-conductive with respect to the flow of discharge current from the series string of electrochemical cells. In accordance with another embodiment, equalization of the series string of cells is effected during a discharge cycle.
Discharge indices for water quality loads
Vogel, Richard M.; Stedinger, Jery R.; Hooper, Richard P.
2003-01-01
Effective discharge has been used to describe the streamflow level that is responsible for transporting the most sediment over the long term. Careful inspection reveals that this concept may not have been well defined, and different interpretations have led to conflicting representations. Because total load is ultimately the quantity of interest, we define a new index, the half‐load discharge, which is that discharge above and below which half the total long‐term load is transported. The value of the half‐load discharge is derived for a reasonable model of flows and constituent concentration. The effective discharge has generally been thought to be a relatively common or frequent flood. The half‐load discharge is generally a much greater and less frequent flow than commonly used estimators of the effective discharge. Relations provided here for the frequency and magnitude of the half‐load discharge provide evidence that it is relatively rare floods that transport most of the sediment over the long term. These ideas apply to other constituents as well.
Damping of acoustic waves in a 1 kHz repetition rate XeCl laser
NASA Astrophysics Data System (ADS)
Sentis, M. L.; Canarelli, P.; Delaporte, Ph.; Forestier, B. M.; Fontaine, B. L.
To increase the pulse repetition frequency, the average power, and the beam quality of excimer laser systems, the problem of damping of the strong acoustic waves induced by the active medium excitation must be solved. In order to achieve this goal, different electrodes and acoustic damping configuration have been studied. Excitation of the active medium at high repetition rate (up to 1000 Hz) in a subsonic loop was achieved by means of a classical discharge, through transfer capacitors. The discharge is preionized by X-rays generated by a wire ion plasma gun. The effects of different kinds of electrodes (solid, screen, nickel felt) and transversal acoustic dampers on the stability of the discharge and on the pulse to pulse output energy are discussed.
Seamone, Evan R.; McGuire, James; Clark, Sean; Smee, Daniel; Dow, Daniel
2014-01-01
The cultural divide between US military and civilian institutions amplifies the consequences of military discharge status on public health and criminal justice systems in a manner that is invisible to a larger society. Prompt removal of problematic wounded warriors through retributive justice is more expedient than lengthy mental health treatment. Administrative and punitive discharges usually preclude Department of Veterans Affairs eligibility, posing a heavy public health burden. Moving upstream—through military rehabilitative justice addressing military offenders’ mental health needs before discharge—will reduce the downstream consequences of civilian maladjustment and intergenerational transmission of mental illness. The public health community can play an illuminating role by gathering data about community effect and by advocating for policy change at Department of Veterans Affairs and community levels. PMID:25122020
In situ dc oxygen‐discharge cleaning system for optical elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koide, Tsuneharu; Shidara, Tetsuo; Tanaka, Kenichiro
1989-07-15
In situ dc oxygen‐discharge cleaning arrangements have been developed at the Photon Factory for the removal of carbon contamination from optical surfaces. A high cleaning rate could be achieved by producing an oxygen plasma close to the optical elements with special care taken to avoid any harmful effects from the discharge; contaminant carbon was completely removed within a few hours, at most. This short exposure time and the use of dry oxygen gas resulted in a restoration of the original ultrahigh vacuum without a bakeout. Results with a Seya‐Namioka beamline for gas‐phase experiments showed a flux enhancement amounting to amore » factor of 50, and results with a grasshopper beamline showed a nearly complete recovery of the light intensity, even at the carbon K edge.« less
Discharge characteristics of a high speed fuel injection system
NASA Technical Reports Server (NTRS)
Matthews, Robertson
1925-01-01
Discussed here are some discharge characteristics of a fuel injection system intended primarily for high speed service. The system consisted of a cam actuated fuel pump, a spring loaded automatic injection valve, and a connecting tube.
2014-01-01
To enhance ambulation and facilitate hospital discharge of total artificial heart (TAH)–supported patients, we adapted a mobile ventricular assistance device (VAD) driver (Excor) for TAH use and report on the performance of Excor-driven TAH patients discharged home. Ten patients stabilized on a TAH, driven by the CSS (“Circulatory Support System”), were progressively switched over to the Excor in hospital over 14 days as a pilot, with daily hemodynamics and laboratory parameters measured. Twenty-two stable TAH patients were subsequently placed on the Excor, trained, and discharged home. Clinical and hemodynamic parameters were followed. All pilot study patients were clinically stable on the Excor, with no decrease in TAH output noted (6.3 + 0.3 L/min [day 1] vs. 5.8 + 0.2 L/min [day 14], p = 0.174), with a trend suggesting improvement of both hepatic and renal function. Twenty-two TAH patients were subsequently successfully discharged home on the portable driver and were supported out of hospital for up to 598 days (range, 2–598; mean = 179 ± 140 days), remaining ambulatory, New York Heart Association (NYHA) class I or II, and free of readmission for 88.5% of the time of support. TAH patients may be effectively and safely supported by a mobile drive system. As such, the utility of the TAH may be extended to support patients beyond the hospital, at home, with overall ambulatory freedom. PMID:24577369
Seniors' need for and use of Medicare home health services.
Hubbert, Ann O; Hays, Bevely J
2002-01-01
This study examined: (a) nature and extent of seniors' need for care both at time of admission to and discharge from Medicare home health services, and (b) relationships among admission need, service utilization, need at discharge, and discharge disposition for one episode of home care services. The sample of 195 was stratified by home health discharge disposition: (a) acute group, (b) chronic group, and (c) stable home group. Two classification systems were used to access the seniors' level of need, the mandated Medicare case-mix system (CMS) and a holistic intensity of need system. Findings show that there were no differences in services received by the three groups, that discharge did not mean seniors' need for home care services had been eliminated or reduced, and that caregiver support impacts seniors' need for home care.
Dielectric surface discharges: Effects of combined low-energy and high-energy incident electrons
NASA Technical Reports Server (NTRS)
Balmain, K. G.; Hirt, W.
1981-01-01
Dielectric surface discharges affected by the addition of high energy electrons at 5 pA/sq cm to a primary 20 keV, 10 nA/sq cm electron beam with the high energy broad spectrum particles coming from the beta decay of Strontium 90 are studied. Kapton exhibits significantly increased discharge strength, increased waiting time between discharges, and a decreased number of discharges per specimen before discharge cessation. Mylar exhibits similar but less pronounced effects, while Teflon is relatively unaffected. With Kapton and Mylar, the high energy electrons act in some way to delay the instant of discharge ignition so that more charge can be accumulated and hence released during discharge.
NASA Astrophysics Data System (ADS)
The present conference discusses topics in EM shielding effectiveness, system-level EMC, EMP effects, circuit-level EMI testing, EMI control, analysis techniques for system-level EMC, EMP protective measures, EMI test methods, electrostatic-discharge testing, printed circuit-board design for EMC, and EM environment effects. Also discussed are EMI measurement procedures, EM spectrum-management issues for the 21st century, antenna and propagation effects on EMI testing, EMI control in cables, socioeconomic aspects of EMC, systemwide EMI controls, and EM radiation and coupling.
Assessing dry weather flow contribution in TSS and COD storm events loads in combined sewer systems.
Métadier, M; Bertrand-Krajewski, J L
2011-01-01
Continuous high resolution long term turbidity measurements along with continuous discharge measurements are now recognised as an appropriate technique for the estimation of in sewer total suspended solids (TSS) and Chemical Oxygen Demand (COD) loads during storm events. In the combined system of the Ecully urban catchment (Lyon, France), this technique is implemented since 2003, with more than 200 storm events monitored. This paper presents a method for the estimation of the dry weather (DW) contribution to measured total TSS and COD event loads with special attention devoted to uncertainties assessment. The method accounts for the dynamics of both discharge and turbidity time series at two minutes time step. The study is based on 180 DW days monitored in 2007-2008. Three distinct classes of DW days were evidenced. Variability analysis and quantification showed that no seasonal effect and no trend over the year were detectable. The law of propagation of uncertainties is applicable for uncertainties estimation. The method has then been applied to all measured storm events. This study confirms the interest of long term continuous discharge and turbidity time series in sewer systems, especially in the perspective of wet weather quality modelling.
Chemical Physics of Charge Mechanisms in Nonmetallic Spacecraft Materials.
1979-05-01
techniques may not provide data truly representative of actual in-orbit space - craft charging effects . The results of the discharge characterization...phenomena, commonly referred to collectively as space - !. craft charging effects , can produce undesirable and sometimes serious prob- lems with the...lifetime of future space systems requires a practical understanding of spacecraft charging phenomena and their effects . The laboratory program
Phillips, P J; Schubert, C; Argue, D; Fisher, I; Furlong, E T; Foreman, W; Gray, J; Chalmers, A
2015-04-15
Septic-system discharges can be an important source of micropollutants (including pharmaceuticals and endocrine active compounds) to adjacent groundwater and surface water systems. Groundwater samples were collected from well networks tapping glacial till in New England (NE) and sandy surficial aquifer New York (NY) during one sampling round in 2011. The NE network assesses the effect of a single large septic system that receives discharge from an extended health care facility for the elderly. The NY network assesses the effect of many small septic systems used seasonally on a densely populated portion of Fire Island. The data collected from these two networks indicate that hydrogeologic and demographic factors affect micropollutant concentrations in these systems. The highest micropollutant concentrations from the NE network were present in samples collected from below the leach beds and in a well downgradient of the leach beds. Total concentrations for personal care/domestic use compounds, pharmaceutical compounds and plasticizer compounds generally ranged from 1 to over 20 μg/L in the NE network samples. High tris(2-butoxyethyl phosphate) plasticizer concentrations in wells beneath and downgradient of the leach beds (>20 μg/L) may reflect the presence of this compound in cleaning agents at the extended health-care facility. The highest micropollutant concentrations for the NY network were present in the shoreline wells and reflect groundwater that is most affected by septic system discharges. One of the shoreline wells had personal care/domestic use, pharmaceutical, and plasticizer concentrations ranging from 0.4 to 5.7 μg/L. Estradiol equivalency quotient concentrations were also highest in a shoreline well sample (3.1 ng/L). Most micropollutant concentrations increase with increasing specific conductance and total nitrogen concentrations for shoreline well samples. These findings suggest that septic systems serving institutional settings and densely populated areas in coastal settings may be locally important sources of micropollutants to adjacent aquifer and marine systems. Published by Elsevier B.V.
Improving large-scale groundwater models by considering fossil gradients
NASA Astrophysics Data System (ADS)
Schulz, Stephan; Walther, Marc; Michelsen, Nils; Rausch, Randolf; Dirks, Heiko; Al-Saud, Mohammed; Merz, Ralf; Kolditz, Olaf; Schüth, Christoph
2017-05-01
Due to limited availability of surface water, many arid to semi-arid countries rely on their groundwater resources. Despite the quasi-absence of present day replenishment, some of these groundwater bodies contain large amounts of water, which was recharged during pluvial periods of the Late Pleistocene to Early Holocene. These mostly fossil, non-renewable resources require different management schemes compared to those which are usually applied in renewable systems. Fossil groundwater is a finite resource and its withdrawal implies mining of aquifer storage reserves. Although they receive almost no recharge, some of them show notable hydraulic gradients and a flow towards their discharge areas, even without pumping. As a result, these systems have more discharge than recharge and hence are not in steady state, which makes their modelling, in particular the calibration, very challenging. In this study, we introduce a new calibration approach, composed of four steps: (i) estimating the fossil discharge component, (ii) determining the origin of fossil discharge, (iii) fitting the hydraulic conductivity with a pseudo steady-state model, and (iv) fitting the storage capacity with a transient model by reconstructing head drawdown induced by pumping activities. Finally, we test the relevance of our approach and evaluated the effect of considering or ignoring fossil gradients on aquifer parameterization for the Upper Mega Aquifer (UMA) on the Arabian Peninsula.
Sun, Bing; Xin, Yanbin; Zhu, Xiaomei; Gao, Zhiying; Yan, Zhiyu; Ohshima, Takayuki
2018-04-01
In this work, the bacterial inactivation effects of shock waves, ultraviolet (UV) light, and electric field produced by high-voltage pulsed discharge in liquid with needle-plate configurations were studied. The contributions of each effect on the bacterial killing ratio in the discharge process were obtained individually by modifying reactor type and usage of glass, quartz, and black balloons. The results showed that the location from the discharge center axis significantly influenced the effects of shock waves and electric fields, although the effect of UV light was not affected by the location in the reactor. The effects of shock waves and electric fields were improved by decreasing the distance from the discharge center axis. Under this experimental condition, the effects of shock waves, UV light, and electric fields produced by discharges on bacterial inactivation were approximately 36.1%, 30.8%, 12.7%, respectively. Other contributions seemed to be due to activated species. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Yanran; Chen, Duo; Zhang, Jiwei; Chen, Ning; Li, Xiaoqi; Gong, Xiaojing
2017-09-01
GIS (gas insulated switchgear), is an important equipment in power system. Partial discharge plays an important role in detecting the insulation performance of GIS. UHF method and ultrasonic method frequently used in partial discharge (PD) detection for GIS. It is necessary to investigate UHF method and ultrasonic method for partial discharge in GIS. However, very few studies have been conducted on the method combined this two methods. From the view point of safety, a new method based on UHF method and ultrasonic method of PD detection for GIS is proposed in order to greatly enhance the ability of anti-interference of signal detection and the accuracy of fault localization. This paper presents study aimed at clarifying the effect of the new method combined UHF method and ultrasonic method. Partial discharge tests were performed in laboratory simulated environment. Obtained results show the ability of anti-interference of signal detection and the accuracy of fault localization for this new method combined UHF method and ultrasonic method.
Medina, M; Andrade, S; Faugeron, S; Lagos, N; Mella, D; Correa, J A
2005-04-01
Copper mine tailings have been discharged around the city of Chanaral, in northern Chile, for more than 60 years. This report summarizes a 17-month long monitoring study of species richness and biodiversity at five intertidal sites around the point of the tailing discharge. Total dissolved copper in sites close to the point of discharge varied between 8.72 microg/l and 34.15 microg/l, showing that there has not been a significant reduction since 1994. However, species richness has increased, suggesting a possible recovery of the system. While diversity of sessile organisms correlates negatively with dissolved copper, diversity of mobile invertebrates did not correlate with the metal concentration. To explain the observed results we discuss the role of algal turf interference on the distribution of mobile invertebrates at reference sites, a top-down effect caused by the absence of carnivores at impacted sites, and an avoidance strategy by some species to reduce their contact with contaminated seawater.
46 CFR 95.15-25 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 193.15-25 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 95.15-25 - Discharge outlets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 95.15-25 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 193.15-25 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...
Bothner, Michael H.; Butman, Bradford; Casso, Michael A.
2010-01-01
During the period August 14-23, 2002, the discharge of total suspended solids (TSS) from the Massachusetts Water Resources Authority sewage-treatment plant ranged from 32 to 132 milligrams per liter, causing the monthly average discharge to exceed the limit specified in the National Pollution Discharge Elimination System permit. Time-series monitoring data collected by the U.S. Geological Survey in western Massachusetts Bay were examined to evaluate changes in environmental conditions during and after this exceedance event. The rate of sediment trapping and the concentrations of near-bottom suspended sediment measured near the outfall in western Massachusetts Bay increased during this period. Because similar increases in sediment-trapping rate were observed in the summers of 2003 and 2004, however, the increase in 2002 cannot be definitively attributed to the increased TSS discharge. Concentrations of copper and silver in trapped sediment collected 10 and 20 days following the 2002 TSS event were elevated compared to those in pre-event samples. Maximum concentrations were less than 50 percent of toxicity guidelines. Photographs of surficial bottom sediments obtained before and after the TSS event do not show sediment accumulation on the sea floor. Concentrations of silver, Clostridium perfringens, and clay in surficial bottom sediments sampled 10 weeks after the discharge event at a depositional site 3 kilometers west of the outfall were unchanged from those in samples obtained before the event. Simulation of the TSS event by using a coupled hydrodynamic-wave-sediment-transport model could enhance understanding of these observations and of the effects of the exceedance on the local marine environment.
Effect of catalysts on dc corona discharge poisoning
NASA Astrophysics Data System (ADS)
Pekárek, S.
2011-02-01
The processes of ozone generation in non-thermal plasma produced by an electrical discharge in air at atmospheric pressure are burdened by the presence of nitrogen oxides, which on the one hand contribute to ozone generation and on the other hand are responsible for unpleasant discharge poisoning. The term discharge poisoning refers to the situation when the discharge ozone formation completely breaks down. Discharge poisoning can be affected by placing a catalyst in the discharge chamber. For the dc hollow needle to mesh corona discharge enhanced by the flow of air through the needle electrode we studied the effect of titanium dioxide TiO2, ZSM-5 zeolite or Cu++ZSM-5 zeolite on discharge poisoning by monitoring the ozone, nitrogen monoxide and nitrogen dioxide discharge production. We found that placing globules of any of these catalysts on the mesh decreases the energy density of the onset of discharge poisoning, and this energy density is smallest for a discharge with globules of a TiO2 on the mesh.
Characterizing shipboard bilgewater effluent before and after treatment.
McLaughlin, Christine; Falatko, Debra; Danesi, Robin; Albert, Ryan
2014-04-01
Operational discharges from oceangoing vessels, including discharges of bilgewater, release oil into marine ecosystems that can potentially damage marine life, terrestrial life, human health, and the environment. Bilgewater is a mix of oily fluids and other pollutants from a variety of sources onboard a vessel. If bilgewater cannot be retained onboard, it must be treated by an oily water separator before discharge for larger ocean-going vessels. We evaluated the effectiveness of bilgewater treatment systems by analyzing land-based type approval data, collecting and analyzing shipboard bilgewater effluent data, assessing bilgewater effluent concentrations compared to regulatory standards, evaluating the accuracy of shipboard oil content monitors relative to analytical results, and assessing additional pollution reduction benefits of treatment systems. Land-based type approval data were gathered for 20 treatment systems. Additionally, multiple samples of influent and effluent from operational bilgewater treatment systems onboard three vessels were collected and analyzed, and compared to the land-based type approval data. Based on type approval data, 15 treatment systems were performing below 5 ppm oil. Shipboard performance measurements verified land-based type approval data for the three systems that were sampled. However, oil content monitor readings were more variable than actual oil concentration measurements from effluent samples, resulting in false negatives and positives. The treatment systems sampled onboard for this study generally reduced the majority of other potentially harmful pollutants, which are not currently regulated, with the exception of some heavy metal analytes.
Mills, Pamela Ruth; Weidmann, Anita Elaine; Stewart, Derek
2017-12-01
Background Electronic prescribing system implementation is recommended to improve patient safety and general practitioner's discharge information communication. There is a paucity of information about hospital staff perspectives before and after system implementation. Objective To explore hospital staff views regarding prescribing and discharge communication systems before and after hospital electronic prescribing and medicines administration (HEPMA) system implementation. Setting A 560 bed United Kingdom district general hospital. Methods Semi-structured face-to-face qualitative interviews with a purposive sample of hospital staff involved in the prescribing and discharge communication process. Interviews transcribed verbatim and coded using the Framework Approach. Behavioural aspects mapped to Theoretical Domains Framework (TDF) to highlight associated behavioural change determinants. Main outcome measure Staff perceptions before and after implementation. Results Nineteen hospital staff (consultant doctors, junior doctors, pharmacists and advanced nurse practitioners) participated before and after implementation. Pre-implementation main themes were inpatient chart and discharge letter design and discharge communication process with issues of illegible and inaccurate information. Improved safety was anticipated after implementation. Post-implementation themes were improved inpatient chart clarity and discharge letter quality. TDF domains relevant to staff behavioural determinants preimplementation were knowledge (task or environment); skills (competence); social/professional roles and identity; beliefs about capabilities; environmental context and resources (including incidents). An additional two were relevant post-implementation: social influences and behavioural regulation (including self-monitoring). Participants described challenges and patient safety concerns pre-implementation which were mostly resolved post-implementation. Conclusion HEPMA implementation produced perceptions of patient safety improvement. TDF use enabled behaviour change analysis due to implementation, for example, staff adoption of behaviours to ensure general practitioners receive good quality discharge information.
Packham, C; Gray, D; Weston, C; Large, A; Silcocks, P; Hampton, J
2002-01-01
Objectives: To explore the effects of alternative methods of defining myocardial infarction on the numbers and survival patterns of patients identified as having sustained a confirmed myocardial infarct. Design: An inclusive historical cohort of patients admitted with a suspected heart attack. Patients were recoded from raw clinical data (collected at the index admission) to the epidemiological definitions of myocardial infarction used by the Nottingham heart attack register (NHAR), the World Health Organization (MONICA), and the UK heart attack study. Setting: Single health district. Patients: The NHAR identified all patients admitted in 1992 with suspected myocardial infarction. Outcome measures: Survival at 30 days and four year postdischarge. Results: 2739 patients were identified, of whom 90% survived to discharge. Recoding increased the numbers of patients defined as having confirmed myocardial infarction from 26% under the original NHAR classification to 69%, depending on the classification system used. In confirmed myocardial infarction, subsequent 30 day survival from admission varied from 77–86% depending on the classification system; four year survival after discharge was not affected. The distribution of important prognostic variables differed significantly between groups of patients with confirmed myocardial infarction defined by different systems. Patients with suspected but unconfirmed myocardial infarction under all classification systems had a worse postdischarge mortality. Conclusions: The classification system used had a substantial effect on the numbers of patients identified as having had a myocardial infarct, and on the 30 day survival. There were significant numbers of patients with more atypical presentations, not labelled as myocardial infarction, who did badly following discharge. More research is needed on these patients. PMID:12231586
PRN 93-10: Effluent Discharge Labeling Statements
This notice describes revised effluent discharge labeling statements required on all manufacturing use products and end use products that may be discharged to waters of the United States ormunicipal sewer systems.
46 CFR 76.17-20 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.17-20 Section 76.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-20 Discharge outlets. (a) Discharge outlets shall be of an...
46 CFR 95.17-20 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.17-20 Section 95.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-20 Discharge outlets. (a) Discharge outlets shall be...
46 CFR 95.17-20 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.17-20 Section 95.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-20 Discharge outlets. (a) Discharge outlets shall be...
46 CFR 76.17-20 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.17-20 Section 76.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-20 Discharge outlets. (a) Discharge outlets shall be of an...
32 CFR 724.402 - Naval Discharge Review Board.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 5 2011-07-01 2011-07-01 false Naval Discharge Review Board. 724.402 Section 724.402 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY PERSONNEL NAVAL DISCHARGE REVIEW BOARD Principal Elements of the Navy Department Discharge Review System § 724.402 Naval...
32 CFR 724.402 - Naval Discharge Review Board.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 5 2010-07-01 2010-07-01 false Naval Discharge Review Board. 724.402 Section 724.402 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY PERSONNEL NAVAL DISCHARGE REVIEW BOARD Principal Elements of the Navy Department Discharge Review System § 724.402 Naval...
Chromium toxicity to nitrifying bacteria: implications to wastewater treatment
Chromium, a heavy metal that enters wastewater treatment plants (WWTPs) through industrial discharges, can be toxic to microorganisms carrying out important processes within biological wastewater treatment systems. The effect of Cr(III) and Cr(VI) on ammonia dependent specific ox...
Compressor discharge bleed air circuit in gas turbine plants and related method
Anand, Ashok Kumar; Berrahou, Philip Fadhel; Jandrisevits, Michael
2002-01-01
A gas turbine system that includes a compressor, a turbine component and a load, wherein fuel and compressor discharge bleed air are supplied to a combustor and gaseous products of combustion are introduced into the turbine component and subsequently exhausted to atmosphere. A compressor discharge bleed air circuit removes bleed air from the compressor and supplies one portion of the bleed air to the combustor and another portion of the compressor discharge bleed air to an exhaust stack of the turbine component in a single cycle system, or to a heat recovery steam generator in a combined cycle system. In both systems, the bleed air diverted from the combustor may be expanded in an air expander to reduce pressure upstream of the exhaust stack or heat recovery steam generator.
Compressor discharge bleed air circuit in gas turbine plants and related method
Anand, Ashok Kumar [Niskayuna, NY; Berrahou, Philip Fadhel [Latham, NY; Jandrisevits, Michael [Clifton Park, NY
2003-04-08
A gas turbine system that includes a compressor, a turbine component and a load, wherein fuel and compressor discharge bleed air are supplied to a combustor and gaseous products of combustion are introduced into the turbine component and subsequently exhausted to atmosphere. A compressor discharge bleed air circuit removes bleed air from the compressor and supplies one portion of the bleed air to the combustor and another portion of the compressor discharge bleed air to an exhaust stack of the turbine component in a single cycle system, or to a heat recovery steam generator in a combined cycle system. In both systems, the bleed air diverted from the combustor may be expanded in an air expander to reduce pressure upstream of the exhaust stack or heat recovery steam generator.
Data network, collection, and analysis in the Diamond Valley flow system, central Nevada
Knochenmus, Lari A.; Berger, David L.; Moreo, Michael T.; Smith, J. LaRue
2011-01-01
Future groundwater development and its effect on future municipal, irrigation, and alternative energy uses in the Diamond Valley flow system are of concern for officials in Eureka County, Nevada. To provide a better understanding of the groundwater resources, the U.S. Geological Survey, in cooperation with Eureka County, commenced a multi-phase study of the Diamond Valley flow system in 2005. Groundwater development primarily in southern Diamond Valley has resulted in water-level declines since the 1960s ranging from less than 5 to 100 feet. Groundwater resources in the Diamond Valley flow system outside of southern Diamond Valley have been relatively undeveloped. Data collected during phase 2 of the study (2006-09) included micrometeorological data at 4 evapotranspiration stations, 3 located in natural vegetation and 1 located in an agricultural field; groundwater levels in 95 wells; water-quality constituents in aquifers and springs at 21 locations; lithologic information from 7 recently drilled wells; and geophysical logs from 3 well sites. This report describes what was accomplished during phase 2 of the study, provides the data collected, and presents the approaches to strengthen relations between evapotranspiration rates measured at micrometeorological stations and spatially distributed groundwater discharge. This report also presents the approach to improve delineation of areas of groundwater discharge and describes the current methodology used to improve the accuracy of spatially distributed groundwater discharge rates in the Diamond Valley flow system.
NASA Astrophysics Data System (ADS)
Montiel, Daniel; Dimova, Natasha; Andreo, Bartolomé; Prieto, Jorge; García-Orellana, Jordi; Rodellas, Valentí
2018-02-01
Groundwater discharge in coastal karst aquifers worldwide represents a substantial part of the water budget and is a main pathway for nutrient transport to the sea. Groundwater discharge to the sea manifests under different forms, making its assessment very challenging particularly in highly heterogeneous coastal systems karst systems. In this study, we present a methodology approach to identify and quantify four forms of groundwater discharge in a mixed lithology system in southern Spain (Maro-Cerro Gordo) that includes an ecologically protected coastal area comprised of karstic marble. We found that groundwater discharge to the sea occurs via: (1) groundwater-fed creeks, (2) coastal springs, (3) diffuse groundwater seepage through seabed sediments, and (4) submarine springs. We used a multi-method approach combining tracer techniques (salinity, 224Ra, and 222Rn) and direct measurements (seepage meters and flowmeters) to evaluate the discharge. Groundwater discharge via submarine springs was the most difficult to assess due to their depth (up to 15 m) and extensive development of the springs conduits. We determined that the total groundwater discharge over the 16 km of shoreline of the study area was at least 11 ± 3 × 103 m3 d-1 for the four types of discharge assessed. Groundwater-derived nitrate (NO3-) fluxes to coastal waters over ∼3 km (or 20%) in a highly populated and farmed section of Maro-Cerro Gordo was 641 ± 166 mol d-1, or ∼75% of the total NO3- loading in the study area. We demonstrate in this study that a multi-method approach must be applied to assess all forms of SGD and derived nutrient fluxes to the sea in highly heterogeneous karst aquifer systems.
Hoppe, H; Messmann, S; Giga, A; Grüning, H
2009-01-01
In some cities, industrial enterprises' discharges into municipal sewage systems have a major impact on the quantity and quality of inflows to the municipal treatment plants. In many cases, industrial discharges stand out on account of the great fluctuations in their volumetric rates of flow, pollution loads and temperatures. As a result, these discharges put a great strain on the sewage system, the treatment plant, and ultimately the receiving waters. The enterprises concerned have to pay the treatment plant operators fees based on the load and/or volume discharged. In most cases, qualitative monitoring operations merely consist of spot checks. This means that continuously surveillance is not possible and infringements of the permissible limit values are only discovered by accident. If impermissible discharges are carried out that may be susceptible to causing a treatment plant failure, the rapid initiation of countermeasures is not possible. Hence, spectrometer probes and mobile flowmeters were used in order to determine volumetric rates of flow, COD concentrations, and ultimately the loads discharged. The possibilities for, and limits to, online monitoring as well as shortcomings of spot-checks are discussed in the course of this paper, which also includes an uncertainty analysis.
Gardner, Philip M.
2018-04-10
Pah Tempe Springs, located in Washington County, Utah, contribute about 95,000 tons of dissolved solids annually along a 1,500-foot gaining reach of the Virgin River. The river gains more than 10 cubic feet per second along the reach as thermal, saline springwater discharges from dozens of orifices located along the riverbed and above the river on both banks. The spring complex discharges from fractured Permian Toroweap Limestone where the river crosses the north-south trending Hurricane Fault. The Bureau of Reclamation Colorado River Basin Salinity Control Program is evaluating the feasibility of capturing and desalinizing the discharge of Pah Tempe Springs to improve downstream water quality in the Virgin River. The most viable plan, identified by the Bureau of Reclamation in early studies, is to capture spring discharge by pumping thermal groundwater from within the Hurricane Fault footwall damage zone and to treat this water prior to returning it to the river.Three multiple-day interference tests were conducted between November 2013 and November 2014, wherein thermal groundwater was pumped from fractured carbonate rock in the fault damage zone at rates of up to 7 cubic feet per second. Pumping periods for these tests lasted approximately 66, 74, and 67 hours, respectively, and the tests occurred with controlled streamflows of approximately 2.0, 3.5, and 24.5 cubic feet per second, respectively, in the Virgin River upstream from the springs reach. Specific conductance, water temperature, and discharge were monitored continuously in the river (upstream and downstream of the springs reach) at selected individual springs, and in the pumping discharge during each of the tests. Water levels were monitored in three observation wells screened in the thermal system. Periodic stream and groundwater samples were analyzed for dissolved-solids concentration and the stable isotopes of oxygen and hydrogen. Additional discrete measurements of field parameters (specific conductance, water temperature, pH, and discharge) were made at up to 26 sites along the springs reach. These data demonstrate the interaction between the saline, thermal groundwater system and the Virgin River, and provide estimates of reductions in dissolved-solids loads to the river.The interference tests show that pumping thermal groundwater from the shallow carbonate aquifer adjacent to the springs is effective at capturing high dissolved-solids loads discharging from Pah Tempe Springs before they enter the Virgin River. Discharge measurements made in the Virgin River downstream of the springs reach show that streamflow is reduced by approximately the amount pumped, indicating that complete capture of thermal discharge is possible. During the February 2014 test, the dissolved-solids load removed by pumping (190 tons per day) was approximately equal to the dissolved-solids load reduction observed in the river below the springs reach, indicating near 100-percent efficient capture of spring-sourced dissolved solids. However, an observed decrease in temperature and specific conductance of the pumping discharge during the high-flow test in November 2014 showed that capture of the cool, fresh river water can occur and is more likely at a higher stage in the Virgin River.
Wagner, Chad R.; Mueller, David S.
2011-01-01
A negative bias in discharge measurements made with an acoustic Doppler current profiler (ADCP) can be caused by the movement of sediment on or near the streambed. The integration of a global positioning system (GPS) to track the movement of the ADCP can be used to avoid the systematic negative bias associated with a moving streambed. More than 500 discharge transects from 63 discharge measurements with GPS data were collected at sites throughout the US, Canada, and New Zealand with no moving bed to compare GPS and bottom-track-referenced discharges. Although the data indicated some statistical bias depending on site conditions and type of GPS data used, these biases were typically about 0.5% or less. An assessment of differential correction sources was limited by a lack of data collected in a range of different correction sources and different GPS receivers at the same sites. Despite this limitation, the data indicate that the use of Wide Area Augmentation System (WAAS) corrected positional data is acceptable for discharge measurements using GGA as the boat-velocity reference. The discharge data based on GPS-referenced boat velocities from the VTG data string, which does not require differential correction, were comparable to the discharges based on GPS-referenced boat velocities from the differentially-corrected GGA data string. Spatial variability of measure discharges referenced to GGA, VTG and bottom-tracking is higher near the channel banks. The spatial variability of VTG-referenced discharges is correlated with the spatial distribution of maximum Horizontal Dilution of Precision (HDOP) values and the spatial variability of GGA-referenced discharges is correlated with proximity to channel banks.
Means of introducing an analyte into liquid sampling atmospheric pressure glow discharge
Marcus, R. Kenneth; Quarles, Jr., Charles Derrick; Russo, Richard E.; Koppenaal, David W.; Barinaga, Charles J.; Carado, Anthony J.
2017-01-03
A liquid sampling, atmospheric pressure, glow discharge (LS-APGD) device as well as systems that incorporate the device and methods for using the device and systems are described. The LS-APGD includes a hollow capillary for delivering an electrolyte solution to a glow discharge space. The device also includes a counter electrode in the form of a second hollow capillary that can deliver the analyte into the glow discharge space. A voltage across the electrolyte solution and the counter electrode creates the microplasma within the glow discharge space that interacts with the analyte to move it to a higher energy state (vaporization, excitation, and/or ionization of the analyte).
Patel, Hemali; Fang, Margaret C; Mourad, Michelle; Green, Adrienne; Wachter, Robert M; Murphy, Ryan D; Harrison, James D
2018-06-01
Improving early discharges may improve patient flow and increase hospital capacity. We conducted a national survey of academic medical centers addressing the prevalence, importance, and effectiveness of early-discharge initiatives. We assembled a list of hospitalist and general internal medicine leaders at 115 US-based academic medical centers. We emailed each institutional representative a 30-item online survey regarding early-discharge initiatives. The survey included questions on discharge prioritization, the prevalence and effectiveness of early-discharge initiatives, and barriers to implementation. We received 61 responses from 115 institutions (53% response rate). Forty-seven (77%) "strongly agreed" or "agreed" that early discharge was a priority. "Discharge by noon" was the most cited goal (n = 23; 38%) followed by "no set time but overall goal for improvement" (n = 13; 21%). The majority of respondents reported early discharge as more important than obtaining translators for non-English-speaking patients and equally important as reducing 30-day readmissions and improving patient satisfaction. The most commonly reported factors delaying discharge were availability of postacute care beds (n = 48; 79%) and patient-related transport complications (n = 44; 72%). The most effective early discharge initiatives reported involved changes to the rounding process, such as preemptive identification and early preparation of discharge paperwork (n = 34; 56%) and communication with patients about anticipated discharge (n = 29; 48%). There is a strong interest in increasing early discharges in an effort to improve hospital throughput and patient flow. © 2017 Society of Hospital Medicine.
Hangar Fire Suppression Utilizing Novec 1230
2018-01-01
The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...fuel fires in aircraft hangars. A 30×30×8-ft concrete-and-steel test structure was constructed for this test series . Four discharge assemblies...structure. System discharge parameters---discharge time , discharge rate, and quantity of agent discharged---were adjusted to produce the desired Novec 1230
Desimone, Leslie A.; Howes, Brian L.
1998-01-01
Nitrogen transport and transformations were followed over the initial 3 years of development of a plume of wastewater-contaminated groundwater in Cape Cod, Massachusetts. Ammonification and nitrification in the unsaturated zone and ammonium sorption in the saturated zone were predominant, while loss of fixed nitrogen through denitrification was minor. The major effect of transport was the oxidation of discharged organic and inorganic forms to nitrate, which was the dominant nitrogen form in transit to receiving systems. Ammonification and nitrification in the unsaturated zone transformed 16–19% and 50–70%, respectively, of the total nitrogen mass discharged to the land surface during the study but did not attenuate the nitrogen loading. Nitrification in the unsaturated zone also contributed to pH decrease of 2 standard units and to an N2O increase (46–660 µg N/L in the plume). Other processes in the unsaturated zone had little net effect: Ammonium sorption removed <1% of the total discharged nitrogen mass; filtering of particulate organic nitrogen was less than 3%; ammonium and nitrate assimilation was less than 6%; and ammonia volatilization was less than 0.25%. In the saturated zone a central zone of anoxic groundwater (DO ≤ 0.05 mg/L) was first detected 17 months after effluent discharge to the aquifer began, which expanded at about the groundwater-flow velocity. Although nitrate was dominant at the water table, the low, carbon-limited rates of denitrification in the anoxic zone (3.0–9.6 (ng N/cm3)/d) reduced only about 2% of the recharged nitrogen mass to N2. In contrast, ammonium sorption in the saturated zone removed about 16% of the recharged nitrogen mass from the groundwater. Ammonium sorption was primarily limited to anoxic zone, where nitrification was prevented, and was best described by a Langmuir isotherm in which effluent ionic concentrations were simulated. The initial nitrogen load discharged from the groundwater system may depend largely on the growth and stability of the sorbed ammonium pool, which in turn depends on effluent-loading practices, subsurface microbial processes, and saturation of available exchange sites.
Magnitude of Anemia at Discharge Increases 30-Day Hospital Readmissions.
Koch, Colleen G; Li, Liang; Sun, Zhiyuan; Hixson, Eric D; Tang, Anne; Chagin, Kevin; Kattan, Michael; Phillips, Shannon C; Blackstone, Eugene H; Henderson, J Michael
2017-12-01
Anemia during hospitalization is associated with poor health outcomes. Does anemia at discharge place patients at risk for hospital readmission within 30 days of discharge? Our objectives were to examine the prevalence and magnitude of anemia at hospital discharge and determine whether anemia at discharge was associated with 30-day readmissions among a cohort of hospitalizations in a single health care system. From January 1, 2009, to August 31, 2011, there were 152,757 eligible hospitalizations within a single health care system. The endpoint was any hospitalization within 30 days of discharge. The University HealthSystem Consortium's clinical database was used for demographics and comorbidities; hemoglobin values are from the hospitals' electronic medical records, and readmission status was obtained from the University HealthSystem Consortium administrative data systems. Mild anemia was defined as hemoglobin of greater than 11 to less than 12 g/dl in women and greater than 11 to less than 13 g/dl in men; moderate, greater than 9 to less than or equal to 11 g/dl; and severe, less than or equal to 9 g/dl. Logistic regression was used to assess the association of anemia and 30-day readmissions adjusted for demographics, comorbidity, and hospitalization type. Among 152,757 hospitalizations, 72% of patients were discharged with anemia: 31,903 (21%), mild; 52,971 (35%), moderate; and 25,522 (17%), severe. Discharge anemia was associated with severity-dependent increased odds for 30-day hospital readmission compared with those without anemia: for mild anemia, 1.74 (1.65-1.82); moderate anemia, 2.76 (2.64-2.89); and severe anemia, 3.47 (3.30-3.65), P < 0.001. Anemia at discharge is associated with a severity-dependent increased risk for 30-day readmission. A strategy focusing on anemia treatment care paths during index hospitalization offers an opportunity to influence subsequent readmissions.
Dielectric surface discharges - Effects of combined low-energy and high-energy incident electrons
NASA Technical Reports Server (NTRS)
Balmain, K. G.; Hirt, W.
1983-01-01
Dielectric surface discharges affected by the addition of high energy electrons at 5 pA/sq cm to a primary 20 keV, 10 nA/sq cm electron beam with the high energy broad spectrum particles coming from the beta decay of Strontium 90 are studied. Kapton exhibits significantly increased discharge strength, increased waiting time between discharges, and a decreased number of discharges per specimen before discharge cessation. Mylar exhibits similar but less pronounced effects, while Teflon is relatively unaffected. With Kapton and Mylar, the high energy electrons act in some way to delay the instant of discharge ignition so that more charge can be accumulated and hence released during discharge. Previously announced in STAR as N82-14222
Harsh, John F.; Laczniak, Randell J.
1990-01-01
The ground-water flow system in the Coastal Plain of Virginia and adjacent parts of Maryland and North Carolina consists of a water table aquifer and an underlying sequence of confined aquifers and intervening confining units composed of unconsolidated sand and clay. A digital flow model was developed to enhance knowledge of the behavior of the ground-water flow system in response to its development. Ten pumping periods covering 90 yr of withdrawal simulated the history of ground-water development. Simulated potentiometric-surface maps for 1980 show lowered water levels and the development of coalescing cones of depression around the cities of Franklin, Suffolk, and Williamsburg and the town of West Point, all in Virginia. The largest simulated decline in water level, about 210 ft was near Franklin. Water budgets indicate that over the period of simulation (1891-1980): (1) pumpage from the model area increased by about 105 Mgal/d; (2) lateral boundary outflow increased by about 5 Mgal/d; (3) ground-water flow to streams and coastal water decreased by about 107.5 Mgal/d; (4) lateral boundary inflow increased by about 0.7 Mgal/d, and (5) water released from aquifer storage increased by about 1.6 Mgal/d. Simulated rates of recharge into the confined aquifer system at the end of the final pumping period (1980) varied up to 3.8 in/yr. and simulated rates of discharge out of the confined system varied up to 2.2 in/yr. Results of simulations show an increase of about 110 Mgal/d into the confined system from the unconfined system over the period of simulation. This increase in flow into the confined system affected local discharge of ground water to streams and regional discharge to coastal water. Lowering the storage coefficient of the aquifer had a minimal effect simulated water levels, whereas increasing the storage coefficient had a much more significant effect.
Experimental Evaluation of a High Speed Flywheel for an Energy Cache System
NASA Astrophysics Data System (ADS)
Haruna, J.; Murai, K.; Itoh, J.; Yamada, N.; Hirano, Y.; Fujimori, T.; Homma, T.
2011-03-01
A flywheel energy cache system (FECS) is a mechanical battery that can charge/discharge electricity by converting it into the kinetic energy of a rotating flywheel, and vice versa. Compared to a chemical battery, a FECS has great advantages in durability and lifetime, especially in hot or cold environments. Design simulations of the FECS were carried out to clarify the effects of the composition and dimensions of the flywheel rotor on the charge/discharge performance. The rotation speed of a flywheel is limited by the strength of the materials from which it is constructed. Three materials, carbon fiber-reinforced polymer (CFRP), Cr-Mo steel, and a Mg alloy were examined with respect to the required weight and rotation speed for a 3 MJ (0.8 kWh) charging/discharging energy, which is suitable for an FECS operating with a 3-5 kW photovoltaic device in an ordinary home connected to a smart grid. The results demonstrate that, for a stationary 3 MJ FECS, Cr-Mo steel was the most cost-effective, but also the heaviest, Mg-alloy had a good balance of rotation speed and weight, which should result in reduced mechanical loss and enhanced durability and lifetime of the system, and CFRP should be used for applications requiring compactness and a higher energy density. Finally, a high-speed prototype FW was analyzed to evaluate its fundamental characteristics both under acceleration and in the steady state.
Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aleksandrov, A. F.; Petrov, A. K., E-mail: alpetrov57@gmail.com; Vavilin, K. V.
2016-03-15
Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.
NASA Technical Reports Server (NTRS)
Kendall, B. R. F.
1983-01-01
A specialized spectrometer was designed and developed to measure the mass and velocity distributions of neutral particles (molecules and molecular clusters) released from metal-backed Teflon and Kapton films. Promising results were obtained with an insulation breakdown initiation system based on a moveable contact touching the insulated surfaces. A variable energy, high voltage pulse is applied to the contact. The resulting surface damage sites can be made similar in size and shape to those produced by a high voltage electron beam system operating at similar discharge energies. The point discharge apparatus was used for final development of several high speed recording systems and for measurements of the composition of the materials given off by the discharge. Results with this apparatus show evolution of large amounts of fluorocarbon fragments from discharge through Teflon FEP, while discharges through Kapton produce mainly very light hydrocarbon fragments at masses below about 80 a.m.u.
Effect of pulsed current charging on the performance of nickel-cadium cells
NASA Technical Reports Server (NTRS)
Bedrossian, A. A.; Cheh, H. Y.
1977-01-01
The effect of pulsed current charging on the charge acceptance of NiCd cells in terms of mass transfer, kinetic, and structural considerations was investigated. A systemic investigation on the performance of Ni-Cd cells by pulsed current charging was conducted under a variety of well-defined charge-discharge conditions. Experiments were carried out with half cells and film electrodes. The system behavior was studied by charge acceptance, mechanistic, and structural measurements.
Large-capacity pump vaporizer for liquid hydrogen and nitrogen
NASA Technical Reports Server (NTRS)
Hauser, J. A.
1970-01-01
Pump vaporizer system delivers 500 standard cubic feet per minute of hydrogen or nitrogen, one system delivers both gases. Vacuum-jacketed pump discharges liquid hydrogen or liquid nitrogen into vaporizing system heated by ambient air. Principal characteristics of the flow and discharge system, pump, and vaporizer are given.
NASA Technical Reports Server (NTRS)
Davis, Donald Y. (Inventor); Hitch, Bradley D. (Inventor)
1994-01-01
A fluid channeling system includes a fluid ejector, a heat exchanger, and a fluid pump disposed in series flow communication The ejector includes a primary inlet for receiving a primary fluid, and a secondary inlet for receiving a secondary fluid which is mixed with the primary fluid and discharged therefrom as ejector discharge. Heat is removed from the ejector discharge in the heat exchanger, and the heat exchanger discharge is compressed in the fluid pump and channeled to the ejector secondary inlet as the secondary fluid In an exemplary embodiment, the temperature of the primary fluid is greater than the maximum operating temperature of a fluid motor powering the fluid pump using a portion of the ejector discharge, with the secondary fluid being mixed with the primary fluid so that the ejector discharge temperature is equal to about the maximum operating temperature of the fluid motor.
How does the anthropogenic activity affect the spring discharge?
NASA Astrophysics Data System (ADS)
Hao, Yonghong; Zhang, Juan; Wang, Jiaojiao; Li, Ruifang; Hao, Pengmei; Zhan, Hongbin
2016-09-01
Karst hydrological process has largely been altered by climate change and human activity. In many places throughout the world, human activity (e.g. groundwater pumping and dewatering from mining) has intensified and surpassed climate change, where human activity becomes the primary factor that affects groundwater system. But it is still largely unclear how the human activity affects spring discharge in magnitude and periodicity. This study investigates the effects of anthropogenic activity on spring discharge, using the Xin'an Springs of China as an example. The Xin'an Spring discharge were divided into two time periods: the pre-development period from 1956 to 1971 and the post-development period from 1972 to 2013. We confirm the dividing time (i.e. 1971) of these two periods using the Wilcoxon rank-sum test. Then the wavelet transform and wavelet coherence were used to analyze the karst hydrological processes for the two periods respectively. We analyze the correlations of precipitation and the Xin'an spring discharge with the monsoons including the Indian Summer Monsoon (ISM) and the West North Pacific Monsoon (WNPM) and the climate teleconnections including El Niño Southern Oscillation (ENSO) and Pacific Decadal Oscillation (PDO), respectively. The results indicated that the spring discharge was attenuated about 19.63% under the influence of human activity in the Xin'an Springs basin. However, human activity did not alter the size of the resonance frequencies between the spring discharge and the monsoons. In contrast, it reinforced the periodicities of the monsoons-driven spring discharge. It suggested that human has adapted to the major climate periodicities, and human activity had the same rhyme with the primary climate periodicity. In return, human activity enhances the correlation between the monsoons and the spring discharge.
Incidence and Predictors of Microbiology Results Returning Post-Discharge and Requiring Follow-up
El-Kareh, Robert; Roy, Christopher; Brodsky, Gregor; Perencevich, Molly; Poon, Eric G.
2013-01-01
Background Failure to follow up microbiology results pending at discharge can delay appropriate treatment, increasing the risk of patient harm and litigation. Limited data describe the frequency of post-discharge microbiology results requiring a treatment change. Objective To determine the incidence and predictors of post-discharge microbiology results requiring follow-up Design Cross sectional Setting Large academic hospital during 2007 Measurements We evaluated blood, urine, sputum and cerebral spinal fluid (CSF) cultures ordered for hospitalized patients. We identified cultures that returned post-discharge and determined which were clinically important and not treated by an antibiotic to which they were susceptible. We reviewed a random subset to assess the potential need for antibiotic change. Using logistic regression, we identified significant predictors of results requiring follow-up. Results Of 77,349 inpatient culture results, 8,668 (11%) returned post-discharge. Of these, 385 (4%) were clinically important and untreated at discharge. Among 94 manually-reviewed cases, 53% potentially required a change in therapy. Urine cultures were more likely to potentially require therapy change than non-urine cultures (aOR 2.8, 95% CI 1.1–7.2; p=0.03). Also, 76% of 25 results from surgical services potentially required a therapy change, compared with 59% of 29 results from general medicine, 38% of 16 results from oncology and 33% of 24 results from medical subspecialties. Overall, 2.4% of post-discharge cultures potentially necessitated an antibiotic change. Conclusion Many microbiology results return post-discharge and some necessitate a change in treatment. These results arise from many specialties, suggesting the need for a hospital-wide system to ensure effective communication of these results. PMID:21661103
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Gilland, James H.; Haag, Thomas W.; Mackey, Jonathan; Yim, John; Pinero, Luis; Williams, George; Peterson, Peter; Herman, Daniel
2017-01-01
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.
Feasibility of a nickel-metal hydride battery for totally implantable artificial hearts.
Okamoto, E; Yoshida, T; Fujiyoshi, M; Shimanaka, M; Takeuchi, A; Mitamura, Y; Mikami, T
1996-01-01
An implantable rechargeable battery is one of the key technologies for totally implantable artificial hearts. The nickel-metal hydride (Ni-MH) battery is promising for its high energy density of 1.5-2.0 times that of a nickel-cadmium battery. In this study, the effects of pulsatile discharge loads on the operating time and cycle life of Ni-MH batteries at 39 degrees C were studied. Two battery cells (TH-3M, 1,200 mAh, phi 14.5 x 49 mm; Toshiba, Tokyo, Japan) in series were charge/discharge cycled at 39 degrees C using a charge current of 1CA (1,200 mA) and then were fully discharged to 1.0 V/cell under either pulsatile discharge loads, which mimicked a systole (1 A for 0.3 sec) and a diastole (0.4 A for 0.3 sec), or a non pulsatile discharge load equivalent to the average of the pulsatile loads (0.7 A). Each cycle life test was interrupted on the 482nd cycle under pulsatile load, and on the 423rd cycle under non pulsatile load, because of malfunction of each battery charger. The tests showed that the pulsatile discharge cells had significantly (p < 0.001) less operating time (74.0 +/- 7.15 min) throughout the test period (up to 482 days) compared to the cells under equivalent non pulsatile discharge loads (93.7 +/- 7.74 min). The pulsatile-discharged Ni-MH cells provide significantly less operating time than the constantly discharged cells; the Ni-MH battery has an operating time of over 78 min and a cycle life of almost 500 cycles at 39 degrees C. In conclusion, the Ni-MH battery is feasible as an implantable back-up battery for a totally implantable artificial heart system.
Zajd, Henry J.
2007-01-01
The need for accurate real-time discharge in the International Niagara River hydro power system requires reliable, accurate and reproducible data. The U.S. Geological Survey has been widely using Acoustic Doppler Current Profilers (ADCP) to accurately measure discharge in riverine channels since the mid-1990s. The use of the ADCP to measure discharge has remained largely untested at hydroelectric-generation facilities such as the New York Power Authority's (NYPA) Niagara Power Project in Niagara Falls, N.Y. This facility has a large, engineered diversion channel with the capacity of high volume discharges in excess of 100,000 cubic feet per second (ft3/s). Facilities such as this could benefit from the use of an ADCP, if the ADCP discharge measurements prove to be more time effective and accurate than those obtained from the flow-calculation techniques that are currently used. Measurements of diversion flow by an ADCP in the 'Pant Leg' diversion channel at the Niagara Power Project were made on November 6, 7, and 8, 2006, and compared favorably (within 1 percent) with those obtained concurrently by a conventional Price-AA current-meter measurement during one of the ADCP measurement sessions. The mean discharge recorded during each 2-hour individual ADCP measurement session compared favorably with (3.5 to 6.8 percent greater than) the discharge values computed by the flow-calculation method presently in use by NYPA. The use of ADCP technology to measure discharge could ultimately permit increased power-generation efficiency at the NYPA Niagara Falls Power Project by providing improved predictions of the amount of water (and thus the power output) available.
NASA Astrophysics Data System (ADS)
Marec, J.; Bloyet, E.; Chaker, M.; Leprince, P.; Nghiem, P.
Microwave discharges first appeared as unwanted and disturbing effects. However, beginning about the end of World War II, Professors Allis and Brown at the Massachusetts Institute of Technology started to investigate the physics of these discharges. During the next few years, many experimental and theoretical studies were undertaken. However, in the early 60's and for about 15 years, there were few studies of such discharges because of the theoretical difficulties encountered. Effectively, the impossibility of modeling microwave discharges prevented a good understanding of their behavior, and their future use did not appear promising. Recently there has been new interest in these discharges. The plasmas produced by microwave discharges find applications in areas such as: 1) spectroscopy (because of their low contamination), and 2) plasma chemistry. Another advantage of these discharges as compared to d.c. discharges is their ease of operation.
The Impact of Harness Impedance on Hall Thruster Discharge Oscillations
NASA Technical Reports Server (NTRS)
Pinero, Luis R.
2017-01-01
Hall thrusters exhibit characteristic discharge voltage and current oscillations during steady-state operation. The lower frequency breathing-mode current oscillations are inherent to each thruster and could impact thruster operation and power processing unit (PPU) design. The design of the discharge output filter, in particular, the output capacitor is important because it supplies the high peak current oscillations that the thruster demands. However, space-rated, high-voltage capacitors are not readily available and can have significant mass and volume. So, it is important for a PPU designer to know what is the minimum amount of capacitance required to operate a thruster. Through Simulation Program with Integrated Circuit Emphasis modeling and electrical measurements on the Hall Effect Rocket with Magnetic Shielding thruster, it was shown that the harness impedance between the power supply and the thruster is the main contributor towards generating voltage ripple at the thruster. Also, increasing the size of the discharge filter capacitor, as previously implemented during thruster tests, does not reduce the voltage oscillations. The electrical characteristics of the electrical harness between the discharge supply and the thruster is crucial to system performance and could have a negative impact on performance, life and operation.
The Impact of Harness Impedance on Hall Thruster Discharge Oscillations
NASA Technical Reports Server (NTRS)
Pinero, Luis R.
2017-01-01
Hall thrusters exhibit characteristic discharge voltage and current oscillations during steady-state operation. The lower frequency breathing-mode current oscillations are inherent to each thruster and could impact thruster operation and PPU design. The design of the discharge output filter, in particular, the output capacitor is important because it supplies the high peak current oscillations that the thruster demands. However, space-rated, high-voltage capacitors are not readily available and can have significant mass and volume. So, it is important for a PPU designer to know what is the minimum amount of capacitance required to operate a thruster. Through SPICE modeling and electrical measurements on the Hall Effect Rocket with Magnetic Shielding (HERMeS) thruster, it was shown that the harness impedance between the power supply and the thruster is the main contributor towards generating voltage ripple at the thruster. Also, increasing the size of the discharge filter capacitor, as previously implemented during thruster tests, does not reduce the voltage oscillations. The electrical characteristics of the electrical harness between the discharge supply and the thruster is crucial to system performance and could have a negative impact on performance, life and operation.
Lampe, David C.; Bayless, E. Randall
2013-01-01
The U.S. Geological Survey (USGS) collected data and simulated groundwater flow to increase understanding of the hydrology and the effects of drainage alterations to the water table in the vicinity of Long Lake, near Gary, Indiana. East Long Lake and West Long Lake (collectively known as Long Lake) make up one of the largest interdunal lakes within the Indiana Dunes National Lakeshore. The National Park Service is tasked with preservation and restoration of wetlands in the Indiana Dunes National Lakeshore along the southern shoreline of Lake Michigan. Urban development and engineering have modified drainage and caused changes in the distribution of open water, streams and ditches, and groundwater abundance and flow paths. A better understanding of the effects these modifications have on the hydrologic system in the area will help the National Park Service, the Gary Sanitary District (GSD), and local stakeholders manage and protect the resources within the study area.This study used hydrologic data and steady-state groundwater simulations to estimate directions of groundwater flow and the effects of various engineering controls and climatic conditions on the hydrology near Long Lake. Periods of relatively high and low groundwater levels were examined and simulated by using MODFLOW and companion software. Simulated hydrologic modifications examined the effects of (1) removing the beaver dams in US-12 ditch, (2) discontinuing seepage of water from the filtration pond east of East Long Lake, (3) discontinuing discharge from US-12 ditch to the GSD sewer system, (4) decreasing discharge from US-12 ditch to the GSD sewer system, (5) connecting East Long Lake and West Long Lake, (6) deepening County Line Road ditch, and (7) raising and lowering the water level of Lake Michigan.Results from collected hydrologic data indicate that East Long Lake functioned as an area of groundwater recharge during October 2002 and a “flow-through” lake during March 2011, with the groundwater divide south of US-12. Wetlands to the south of West Long Lake act as points of recharge to the surficial aquifer in both dry- and wet-weather conditions.Among the noteworthy results from a dry-weather groundwater flow model simulation are (1) US-12 ditch does not receive water from East Long Lake or West Long Lake, (2) the filtration pond at the east end of East Long Lake, when active, contributed approximately 10 percent of the total water entering East Long Lake, and (3) County Line Road ditch has little effect on simulated water level.Among the noteworthy results from a wet-weather groundwater flow simulation are (1) US-12 ditch does not receive water from East Long Lake or West Long Lake, (2) when the seepage from the filtration pond to the surficial aquifer is not active, sources of inflow to East Long Lake are restricted to only precipitation (46 percent of total) and inflow from the surficial aquifer (54 percent of total), and (3) County Line Road ditch bisects the groundwater divide and creates two water-table mounds south of US-12.The results from a series of model scenarios simulating certain engineering controls and changes in Lake Michigan levels include the following: (1) The simulated removal of beaver dams in US-12 ditch during a wet-weather simulation increased discharge from the ditch to the Gary Sanitary system by 13 percent. (2) Discontinuation of seepage from the filtration pond east of East Long Lake decreased discharge from US-12 ditch to the Gary Sanitary system by 2.3 percent. (3) Simulated discontinuation of discharge from the US-12 ditch to the GSD sewer system increased the area where the water table was estimated to be above the land surface beyond the inundated area in the initial wet-weather simulation. (4) Simulated modifications to the control structure at the discharge point of US-12 ditch to the GSD sewer system can decrease discharge by as much as 61 percent while increasing the simulated inundated area during dry weather and decrease discharge as much as 6 percent while increasing the simulated inundated area during wet weather. (5) Deepening of County Line Road ditch can decrease the discharge from US-12 ditch by 26 percent during dry weather and 24 percent during wet weather, as well as decrease the extent of flooded areas south and east of the filtration pond near Ogden Dunes. (7) The increase of the Lake Michigan water level to match the historical maximum can increase the discharge from US-12 ditch by 14 percent during dry weather and by 9.6 percent during wet weather. (8) The decrease of the Lake Michigan water level to match the historical minimum can decrease the discharge from US-12 ditch by 7.4 percent during dry weather and by 3.1 percent during wet weather.The results of this study can be used by water-resource managers to understand how surrounding ditches affect water levels in East and West Long Lake and in the surrounding wetlands and residential areas. The groundwater model developed in this study can be applied in the future to answer questions about how alterations to the drainage system in the area will affect water levels in East and West Long Lake and surrounding areas. The modeling methods developed in this study provide a template for other studies of groundwater flow and groundwater/surface-water interactions within the shallow surficial aquifer in northern Indiana, and in similar hydrologic settings that include surficial sand aquifers in coastal settings.
Facility and market factors affecting transitions from nursing home to community.
Arling, Greg; Abrahamson, Kathleen A; Cooke, Valerie; Kane, Robert L; Lewis, Teresa
2011-09-01
Research into nursing home transitions has given limited attention to the facility or community contexts. To identify facility and market factors affecting transitions of nursing home residents back to the community. Multilevel models were used to estimate effects of facility and market factors on facility-level community discharge rates after controlling for resident demographic, health, and functional conditions. Facility discharge rates were adjusted using Empirical Bayes estimation. Annual cohort of first-time admissions (N=24,648) to 378 Minnesota nursing facilities in 75 nursing home markets from July 2005 to June 2006. Community discharge within 90 days of admission; facility occupancy, payer mix, ownership, case-mix acuity, size, admissions from hospitals, nurse staffing level, and proportion of admissions preferring or having support to return to the community; and nursing market population size, average occupancy, market concentration, and availability of home and community-based services. Rates of community discharge (Empirical Bayes residual) were highest in facilities with more residents preferring community discharge, more Medicare days, higher nurse staffing levels, and higher occupancy. In addition, facilities had higher community discharge rates if they were located in markets with a greater ratio of home and community-based services recipients to nursing home residents and with larger populations. State Medicaid programs should undertake system-level interventions that encourage nursing facilities to reduce unused bed capacity, balance the mix of payers, invest in nurse staffing, and take other steps to promote community discharges. In addition, states should increase home and community-based services, particularly in markets with low community discharge rates.
Yakhnitsa, V.
2013-01-01
Cerebellar Purkinje cells are excited by two afferent pathways: climbing and mossy fibers. Climbing fibers evoke large “complex spikes” (CSs) that discharge at low frequencies. Mossy fibers synapse on granule cells whose parallel fibers excite Purkinje cells and may contribute to the genesis of “simple spikes” (SSs). Both afferent systems convey vestibular information to folia 9c–10. After making a unilateral labyrinthectomy (UL) in mice, we tested how the discharge of CSs and SSs was changed by the loss of primary vestibular afferent mossy fibers during sinusoidal roll tilt. We recorded from cells identified by juxtacellular neurobiotin labeling. The UL preferentially reduced vestibular modulation of CSs and SSs in folia 8–10 contralateral to the UL. The effects of a UL on Purkinje cell discharge were similar in folia 9c–10, to which vestibular primary afferents project, and in folia 8–9a, to which they do not project, suggesting that vestibular primary afferent mossy fibers were not responsible for the UL-induced alteration of SS discharge. UL also induced reduced vestibular modulation of stellate cell discharge contralateral to the UL. We attribute the decreased modulation to reduced vestibular modulation of climbing fibers. In summary, climbing fibers modulate CSs directly and SSs indirectly through activation of stellate cells. Whereas vestibular primary afferent mossy fibers cannot account for the modulated discharge of SSs or stellate cells, the nonspecific excitation of Purkinje cells by parallel fibers may set an operating point about which the discharges of SSs are sculpted by climbing fibers. PMID:23966673
Gugelmann, Hallam; Shofer, Frances S; Meisel, Zachary F; Perrone, Jeanmarie
2013-09-01
Prescription opioid overdoses and deaths constitute a public health epidemic, and recent studies show that emergency department (ED) prescribers may contribute to this crisis. We hypothesized that a multidisciplinary educational intervention would decrease ED opioid packs dispensed at discharge. This prospective study implemented a "bundle" of interdisciplinary educational modalities: lectures, journal clubs, case discussions, and an electronic medical record decision support tool. Implementation occurred in 2 urban EDs in the same health system at different times ("affiliate," September 2011; "primary," January 2012) to better distinguish its effects. The primary outcome was preintervention/postintervention change in opioid discharge packs dispensed to all patients treated and discharged through August 2012 and was assessed by 2-way analysis of variance. The secondary outcome was bivariate analysis (using Fisher exact test) of change in opioid dispensing among patients with known risk factors for prescription opioid dependence: age less than 65 years, history of substance abuse, chronic pain, or psychiatric disorders. A total of 71,512 and 45,746 patients were evaluated and discharged from primary and affiliate EDs, respectively. Orders for opioid discharge packs decreased from 13.9% to 8.4% and 4.7% to 1.9% at the primary and affiliate hospitals (P < .0001). Dispensing among individuals at risk for opioid dependence at the primary ED decreased from 21.8% to 13.9%. A staged, multidisciplinary intervention targeting nurses, residents, nurse practitioners, and attending physicians was associated with decreased orders for opioid discharge packs in 2 urban EDs. Opioid discharge pack orders decreased slightly more among patients with risk factors for prescription opioid dependence. © 2013.
Zaharia, Carmen
2012-07-01
The paper analyses the environment pollution state in different case studies of economic activities (i.e. co-generation electric and thermal power production, iron profile manufacturing, cement processing, waste landfilling, and wood furniture manufacturing), evaluating mainly the environmental cumulative impacts (e.g. cumulative impact against the health of the environment and different life forms). The status of the environment (air, water resources, soil, and noise) is analysed with respect to discharges such as gaseous discharges in the air, final effluents discharged in natural receiving basins or sewerage system, and discharges onto the soil together with the principal pollutants expressed by different environmental indicators corresponding to each specific productive activity. The alternative methodology of global pollution index (I (GP)*) for quantification of environmental impacts is applied. Environmental data analysis permits the identification of potential impact, prediction of significant impact, and evaluation of cumulative impact on a commensurate scale by evaluation scores (ES(i)) for discharge quality, and global effect to the environment pollution state by calculation of the global pollution index (I (GP)*). The I (GP)* values for each productive unit (i.e. 1.664-2.414) correspond to an 'environment modified by industrial/economic activity within admissible limits, having potential of generating discomfort effects'. The evaluation results are significant in view of future development of each productive unit and sustain the economic production in terms of environment protection with respect to a preventive environment protection scheme and continuous measures of pollution control.
USDA-ARS?s Scientific Manuscript database
Effects of treatment voltage and time of in-package atmospheric cold plasma (ACP) were studied on ozone formation, microbiological quality, surface color, and pH of fresh chicken fillets. Samples were sealed in food trays in air, treated with a dielectric-barrier-discharge (DBD) ACP system, and stor...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-03
... significantly affect plant safety and would not have a significant adverse effect on the probability of an... effluents. No changes to the National Pollution Discharge Elimination System permit are needed. No effects... Magnuson-Steven's Act are expected. There are no impacts to the air or ambient air quality. There are no...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-20
... substantially reducing the harmful effects of impingement and entrainment. As a result, the Agency anticipates... simply EA). This document presents the analysis of compliance costs, closures, energy supply effects, and... propagation of fish, shellfish, and wildlife and provides for recreation in and on the water. 33 U.S.C. 1251(a...
Reporting of Sepsis Cases for Performance Measurement Versus for Reimbursement in New York State.
Prescott, Hallie C; Cope, Tara M; Gesten, Foster C; Ledneva, Tatiana A; Friedrich, Marcus E; Iwashyna, Theodore J; Osborn, Tiffany M; Seymour, Christopher W; Levy, Mitchell M
2018-05-01
Under "Rory's Regulations," New York State Article 28 acute care hospitals were mandated to implement sepsis protocols and report patient-level data. This study sought to determine how well cases reported under state mandate align with discharge records in a statewide administrative database. Observational cohort study. First 27 months of mandated sepsis reporting (April 1, 2014, to June 30, 2016). Hospitalizations with sepsis at New York State Article 28 acute care hospitals. Sepsis regulations with mandated reporting. We compared cases reported to the New York State Department of Health Sepsis Clinical Database with discharge records in the Statewide Planning and Research Cooperative System database. We classified discharges as 1) "coded sepsis discharges"-a diagnosis code for severe sepsis or septic shock and 2) "possible sepsis discharges," using Dombrovskiy and Angus criteria. Of 111,816 sepsis cases reported to the New York State Department of Health Sepsis Clinical Database, 105,722 (94.5%) were matched to discharge records in Statewide Planning and Research Cooperative System. The percentage of coded sepsis discharges reported increased from 67.5% in the first quarter to 81.3% in the final quarter of the study period (mean, 77.7%). Accounting for unmatched cases, as many as 82.7% of coded sepsis discharges were potentially reported, whereas at least 17.3% were unreported. Compared with unreported discharges, reported discharges had higher rates of acute organ dysfunction (e.g., cardiovascular dysfunction 63.0% vs 51.8%; p < 0.001) and higher in-hospital mortality (30.2% vs 26.1%; p < 0.001). Hospital characteristics (e.g., number of beds, teaching status, volume of sepsis cases) were similar between hospitals with a higher versus lower percent of discharges reported, p values greater than 0.05 for all. Hospitals' percent of discharges reported was not correlated with risk-adjusted mortality of their submitted cases (Pearson correlation coefficient 0.11; p = 0.17). Approximately four of five discharges with a diagnosis code of severe sepsis or septic shock in the Statewide Planning and Research Cooperative System data were reported in the New York State Department of Health Sepsis Clinical Database. Incomplete reporting appears to be driven more by underrecognition than attempts to game the system, with minimal bias to risk-adjusted hospital performance measurement.
The effect of NACHRI children's hospital designation on outcome in pediatric malignant brain tumors.
Donoho, Daniel A; Wen, Timothy; Liu, Jonathan; Zarabi, Hosniya; Christian, Eisha; Cen, Steven; Zada, Gabriel; McComb, J Gordon; Krieger, Mark D; Mack, William J; Attenello, Frank J
2017-08-01
OBJECTIVE Although current pediatric neurosurgery guidelines encourage the treatment of pediatric malignant brain tumors at specialized centers such as pediatric hospitals, there are limited data in support of this recommendation. Previous studies suggest that children treated by higher-volume surgeons and higher-volume hospitals may have better outcomes, but the effect of treatment at dedicated children's hospitals has not been investigated. METHODS The authors analyzed the Healthcare Cost and Utilization Project Kids' Inpatient Database (KID) from 2000-2009 and included all patients undergoing a craniotomy for malignant pediatric brain tumors based on ICD-9-CM codes. They investigated the effects of patient demographics, tumor location, admission type, and hospital factors on rates of routine discharge and mortality. RESULTS From 2000 through 2009, 83.6% of patients had routine discharges, and the in-hospital mortality rate was 1.3%. In multivariate analysis, compared with children treated at an institution designated as a pediatric hospital by NACHRI (National Association of Children's Hospitals and Related Institutions), children receiving treatment at a pediatric unit within an adult hospital (OR 0.5, p < 0.01) or a general hospital without a designated pediatric unit (OR 0.4, p < 0.01) were less likely to have routine discharges. Treatment at a large hospital (> 400 beds; OR 1.8, p = 0.02) and treatment at a teaching hospital (OR 1.7, p = 0.02) were independently associated with greater likelihood of routine discharge. However, patients transferred between facilities had a significantly decreased likelihood of routine discharge (OR 0.5, p < 0.01) and an increased likelihood of mortality (OR 5.0, p < 0.01). Procedural volume was not associated with rate of routine discharge or mortality. CONCLUSIONS These findings may have implications for planning systems of care for pediatric patients with malignant brain tumors. The authors hope to motivate future research into the specific factors that may lead to improved outcomes at designated pediatric hospitals.
Understanding the occupational and organizational boundaries to safe hospital discharge.
Waring, Justin; Marshall, Fiona; Bishop, Simon
2015-01-01
Safe hospital discharge relies upon communication and coordination across multiple occupational and organizational boundaries. Our aim was to understand how these boundaries can exacerbate health system complexity and represent latent sociocultural threats to safe discharge. An ethnographic study was conducted in two local health and social care systems (health economies) in England, focusing on two clinical areas: stroke and hip fracture patients. Data collection involved 345 hours of observations and 220 semi-structured interviews with health and social care professionals, patients and their lay carers. Hospital discharge involves a dynamic network of interactions between heterogeneous health and social care actors, each characterized by divergent ways of organizing discharge activities; cultures of collaboration and interaction and understanding of what discharge involves and how it contributes to patient recovery. These interrelated dimensions elaborate the occupational and organisational boundaries that can influence communication and coordination in hospital discharge. Hospital discharge relies upon the coordination of multiple actors working across occupational and organizational boundaries. Attention to the sociocultural boundaries that influence communication and coordination can help inform interventions that might support enhanced discharge safety. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
46 CFR 34.15-25 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
46 CFR 34.17-20 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Discharge outlets-T/ALL. 34.17-20 Section 34.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Fixed Foam Extinguishing Systems, Details § 34.17-20 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
46 CFR 34.17-20 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Discharge outlets-T/ALL. 34.17-20 Section 34.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Fixed Foam Extinguishing Systems, Details § 34.17-20 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
46 CFR 34.15-25 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
46 CFR 34.15-25 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
46 CFR 34.15-25 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
46 CFR 34.15-25 - Discharge outlets-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Discharge outlets-T/ALL. 34.15-25 Section 34.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 34.15-25 Discharge outlets—T/ALL. (a) Discharge outlets shall be of an approved...
Wang, Tiecheng; Qu, Guangzhou; Pei, Shuzhao; Liang, Dongli; Hu, Shibin
2016-07-01
Pulsed discharge plasma (PDP) combined with charcoal (PDP-charcoal) was employed to treat dye wastewater, with methyl orange (MO) as the model pollutant. The charcoal was prepared using spent tea leaves and was characterized by scanning electron microscopy, Fourier-transform infrared spectroscopy, and Boehm titration to investigate the adsorption and catalytic characteristics before and after adsorption and PDP treatment. The prepared charcoal exhibited a high MO adsorption capacity, and the adsorption process followed the pseudo-second-order kinetic model and the Freundlich model. The MO decoloration efficiency reached 69.8 % within 7.5 min of treatment in the PDP-charcoal system, whereas values of 29.2 and 25.9 % were achieved in individual PDP and charcoal systems, respectively. The addition of n-butanol and H2PO4 (-) presented inhibitive effects on MO decoloration in the PDP system. However, these effects were much weaker in the PDP-charcoal system. In addition, the effects of charcoal on O3 and H2O2 formation were evaluated, and the results showed that both the O3 and H2O2 concentrations decreased in the presence of charcoal. The MO decomposition intermediates were analyzed using UV-Vis spectrometry and GC-MS. 1,4-Benzoquinone, 4-nitrophenol, 4-hydroxyaniline, and N,N'-dimethylaniline were detected. A possible pathway for MO decomposition in this system was proposed.
Region 9 NPDES Facilities - Waste Water Treatment Plants
Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.
San Juan Sanz, Isabel; Díaz-Agero-Pérez, Cristina; Robustillo-Rodela, Ana; Pita López, María José; Oliva Iñiguez, Lourdes; Monge-Jodrá, Vicente
2014-10-01
Monitoring surgical site infection (SSI) performed during hospitalization can underestimate its rates due to the shortening in hospital stay. The aim of this study was to determine the actual rates of SSI using a post-discharge monitoring system. All patients who underwent herniorraphy or mastectomy in the Hospital Universitario Ramón y Cajal from 1 January 2011 to 31 December 2011 were included. SSI data were collected prospectively according to the continuous quality improvement indicators (Indicadores Clinicos de Mejora Continua de la Calidad [INCLIMECC]) monitoring system. Post-discharge follow-up was conducted by telephone survey. A total of 409patients were included in the study, of whom 299 underwent a herniorraphy procedure, and 110 underwent a mastectomy procedure. For herniorrhaphy, the SSI rate increased from 6.02% to 7.6% (the post-discharge survey detected 21.7% of SSI). For mastectomy, the SSI rate increased from 1.8% to 3.6% (the post-discharge survey detected 50% of SSI). Post-discharge monitoring showed an increased detection of SSI incidence. Post-discharge monitoring is useful to analyze the real trend of SSI, and evaluate improvement actions. Post-discharge follow-up methods need to standardised. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Optical fiber sensor of partial discharges in High Voltage DC experiments
NASA Astrophysics Data System (ADS)
Búa-Núñez, I.; Azcárraga-Ramos, C. G.; Posada-Román, J. E.; Garcia-Souto, J. A.
2014-05-01
A setup simulating High Voltage DC (HVDC) transformers barriers was developed to demonstrate the effectiveness of an optical fiber (OF) sensor in detecting partial discharges (PD) under these peculiar conditions. Different PD detection techniques were compared: electrical methods, and acoustic methods. Standard piezoelectric sensors (R15i-AST) and the above mentioned OF sensors were used for acoustic detection. The OF sensor was able to detect PD acoustically with a sensitivity better than the other detection methods. The multichannel instrumentation system was tested in real HVDC conditions with the aim of analyzing the behavior of the insulation (mineral oil/pressboard).
NASA Technical Reports Server (NTRS)
Manzella, David; Jacobson, David; Jankovsky, Robert
2001-01-01
A 2.3 kW stationary plasma thruster designed to operate at high voltage was tested at discharge voltages between 300 and 1250 V. Discharge specific impulses between 1600 and 3700 sec were demonstrated with thrust between 40 and 145 mN. Test data indicated that discharge voltage can be optimized for maximum discharge efficiency. The optimum discharge voltage was between 500 and 700 V for the various anode mass flow rates considered. The effect of operating voltage on optimal magnet field strength was investigated. The effect of cathode flow rate on thruster efficiency was considered for an 800 V discharge.
NASA Astrophysics Data System (ADS)
Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng
2018-05-01
Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.
Evaluation of the potentials of humic acid removal in water by gas phase surface discharge plasma.
Wang, Tiecheng; Qu, Guangzhou; Ren, Jingyu; Yan, Qiuhe; Sun, Qiuhong; Liang, Dongli; Hu, Shibin
2016-02-01
Degradation of humic acid (HA), a predominant type of natural organic matter in ground water and surface waters, was conducted using a gas phase surface discharge plasma system. HA standard and two surface waters (Wetland, and Weihe River) were selected as the targets. The experimental results showed that about 90.9% of standard HA was smoothly removed within 40 min's discharge plasma treatment at discharge voltage 23.0 kV, and the removal process fitted the first-order kinetic model. Roles of some active species in HA removal were studied by evaluating the effects of solution pH and OH radical scavenger; and the results presented that O3 and OH radical played significant roles in HA removal. Scanning electron microscope (SEM) and FTIR analysis showed that HA surface topography and molecular structure were changed during discharge plasma process. The mineralization of HA was analyzed by UV-Vis spectrum, dissolved organic carbon (DOC), specific UV absorbance (SUVA), UV absorption ratios, and excitation-emission matrix (EEM) fluorescence. The formation of disinfection by-products during HA sample chlorination was also identified, and CHCl3 was detected as the main disinfection by-product, but discharge plasma treatment could suppress its formation to a certain extent. In addition, approximately 82.3% and 67.9% of UV254 were removed for the Weihe River water and the Wetland water after 40 min of discharge plasma treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wong, Hannah J; Wu, Robert C; Caesar, Michael; Abrams, Howard; Morra, Dante
2010-08-01
Timely access to emergency patient care is an important quality and efficiency issue. Reduced discharges of inpatients at weekends are a reality to many hospitals and may reduce hospital efficiency and contribute to emergency department (ED) congestion. To evaluate the daily number of ED beds occupied by inpatients after evenly distributing inpatient discharges over the course of the week using a computer simulation model. Simulation modelling study from an academic care hospital in Toronto, Canada. Daily historical data from the general internal medicine (GIM) department between 15 January and 15 December for two years, 2005 and 2006, were used for model building and validation, respectively. There was good agreement between model simulations and historical data for both ED and ward censuses and their respective lengths of stay (LOS), with the greatest difference being +7.8% for GIM ward LOS (model: 9.3 days vs historical: 8.7 days). When discharges were smoothed across the 7 days, the number of ED beds occupied by GIM patients decreased by approximately 27-57% while ED LOS decreased 7-14 hours. The model also demonstrated that patients occupying hospital beds who no longer require acute care have a considerable impact on ED and ward beds. Smoothing out inpatient discharges over the course of a week had a positive effect on decreasing the number of ED beds occupied by inpatients. Despite the particular challenges associated with weekend discharges, simulation experiments suggest that discharges evenly spread across the week may significantly reduce bed requirements and ED LOS.
Kinetics of charged particles in a high-voltage gas discharge in a nonuniform electrostatic field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolpakov, V. A., E-mail: kolpakov683@gmail.com; Krichevskii, S. V.; Markushin, M. A.
A high-voltage gas discharge is of interest as a possible means of generating directed flows of low-temperature plasma in the off-electrode space distinguished by its original features [1–4]. We propose a model for calculating the trajectories of charges particles in a high-voltage gas discharge in nitrogen at a pressure of 0.15 Torr existing in a nonuniform electrostatic field and the strength of this field. Based on the results of our calculations, we supplement and refine the extensive experimental data concerning the investigation of such a discharge published in [1, 2, 5–8]; good agreement between the theory and experiment has beenmore » achieved. The discharge burning is initiated and maintained through bulk electron-impact ionization and ion–electron emission. We have determined the sizes of the cathode surface regions responsible for these processes, including the sizes of the axial zone involved in the discharge generation. The main effect determining the kinetics of charged particles consists in a sharp decrease in the strength of the field under consideration outside the interelectrode space, which allows a free motion of charges with specific energies and trajectories to be generated in it. The simulation results confirm that complex electrode systems that allow directed plasma flows to be generated at a discharge current of hundreds or thousands of milliamperes and a voltage on the electrodes of 0.3–1 kV can be implemented in practice [3, 9, 10].« less
A digital underwater video camera system for aquatic research in regulated rivers
Martin, Benjamin M.; Irwin, Elise R.
2010-01-01
We designed a digital underwater video camera system to monitor nesting centrarchid behavior in the Tallapoosa River, Alabama, 20 km below a peaking hydropower dam with a highly variable flow regime. Major components of the system included a digital video recorder, multiple underwater cameras, and specially fabricated substrate stakes. The innovative design of the substrate stakes allowed us to effectively observe nesting redbreast sunfish Lepomis auritus in a highly regulated river. Substrate stakes, which were constructed for the specific substratum complex (i.e., sand, gravel, and cobble) identified at our study site, were able to withstand a discharge level of approximately 300 m3/s and allowed us to simultaneously record 10 active nests before and during water releases from the dam. We believe our technique will be valuable for other researchers that work in regulated rivers to quantify behavior of aquatic fauna in response to a discharge disturbance.
Simulations of Atmospheric Plasma Arcs
NASA Astrophysics Data System (ADS)
Pearcy, Jacob; Chopra, Nirbhav; Jaworski, Michael
2017-10-01
We present the results of computer simulation of cylindrical plasma arcs with characteristics similar to those predicted to be relevant in magnetohydrodynamic (MHD) power conversion systems. These arcs, with core temperatures on the order of 1 eV, place stringent limitations on the lifetime of conventional electrodes used in such systems, suggesting that a detailed analysis of arc characteristics will be crucial in designing more robust electrode systems. Simulations utilize results from NASA's Chemical Equilibrium with Applications (CEA) program to solve the Elenbaas-Heller equation in a variety of plasma compositions, including approximations of coal-burning plasmas as well as pure gas discharges. The effect of carbon dioxide injection on arc characteristics, emulating discharges from molten carbonate salt electrodes, is also analyzed. Results include radial temperature profiles, composition maps, and current-voltage (IV) characteristics of these arcs. Work supported by DOE contract DE-AC02-09CH11466.