Sample records for diseases reference laboratory

  1. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  2. Public health microbiology in Germany: 20 years of national reference centers and consultant laboratories.

    PubMed

    Beermann, Sandra; Allerberger, Franz; Wirtz, Angela; Burger, Reinhard; Hamouda, Osamah

    2015-10-01

    In 1995, in agreement with the German Federal Ministry of Health, the Robert Koch Institute established a public health microbiology system consisting of national reference centers (NRCs) and consultant laboratories (CLs). The goal was to improve the efficiency of infection protection by advising the authorities on possible measures and to supplement infectious disease surveillance by monitoring selected pathogens that have high public health relevance. Currently, there are 19 NRCs and 40 CLs, each appointed for three years. In 2009, an additional system of national networks of NRCs and CLs was set up in order to enhance effectiveness and cooperation within the national reference laboratory system. The aim of these networks was to advance exchange in diagnostic methods and prevention concepts among reference laboratories and to develop geographic coverage of services. In the last two decades, the German public health laboratory reference system coped with all major infectious disease challenges. The European Union and the European Centre for Disease Prevention and Control (ECDC) are considering implementing a European public health microbiology reference laboratory system. The German reference laboratory system should be well prepared to participate actively in this upcoming endeavor. Copyright © 2015 Elsevier GmbH. All rights reserved.

  3. Predictive value and efficiency of laboratory testing.

    PubMed

    Galen, R S

    1980-11-01

    Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.

  4. Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo

    PubMed Central

    Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828

  5. Implementation of a national reference laboratory for Buruli ulcer disease in Togo.

    PubMed

    Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela

    2013-01-01

    In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.

  6. Lyme Disease Diagnosed by Alternative Methods: A Phenotype Similar to That of Chronic Fatigue Syndrome.

    PubMed

    Patrick, David M; Miller, Ruth R; Gardy, Jennifer L; Parker, Shoshana M; Morshed, Muhammad G; Steiner, Theodore S; Singer, Joel; Shojania, Kam; Tang, Patrick

    2015-10-01

    A subset of patients reporting a diagnosis of Lyme disease can be described as having alternatively diagnosed chronic Lyme syndrome (ADCLS), in which diagnosis is based on laboratory results from a nonreference Lyme specialty laboratory using in-house criteria. Patients with ADCLS report symptoms similar to those reported by patients with chronic fatigue syndrome (CFS). We performed a case-control study comparing patients with ADCLS and CFS to each other and to both healthy controls and controls with systemic lupus erythematosus (SLE). Subjects completed a history, physical exam, screening laboratory tests, 7 functional scales, reference serology for Lyme disease using Centers for Disease Control and Prevention criteria, reference serology for other tick-associated pathogens, and cytokine expression studies. The study enrolled 13 patients with ADCLS (12 of whom were diagnosed by 1 alternative US laboratory), 25 patients with CFS, 25 matched healthy controls, and 11 SLE controls. Baseline clinical data and functional scales indicate significant disability among ADCLS and CFS patients and many important differences between these groups and controls, but no significant differences between each other. No ADCLS patient was confirmed as having positive Lyme serology by reference laboratory testing, and there was no difference in distribution of positive serology for other tick-transmitted pathogens or cytokine expression across the groups. In British Columbia, a setting with low Lyme disease incidence, ADCLS patients have a similar phenotype to that of CFS patients. Disagreement between alternative and reference laboratory Lyme testing results in this setting is most likely explained by false-positive results from the alternative laboratory. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. The role and importance of veterinary laboratories in the prevention and control of infectious diseases of animals.

    PubMed

    Truszczyński, M J

    1998-08-01

    Veterinary laboratories which deal with infectious diseases form three groups according to the tasks for which they are responsible. The first group includes central or national veterinary laboratories, national or international reference laboratories, high-security laboratories, district regional or state veterinary diagnostic laboratories. The major role of these laboratories is to assist national Veterinary Services in diagnosing infectious animal diseases. The second group comprises laboratories that produce veterinary diagnostic kits and those that produce veterinary vaccines. The third group is composed of veterinary research laboratories, which generally concentrate on basic research and do not contribute directly to the diagnosis and control of infectious animal diseases. The author describes the objectives of each of the three groups of laboratories.

  8. The role of diagnostic laboratories in support of animal disease surveillance systems.

    PubMed

    Zepeda, C

    2007-01-01

    Diagnostic laboratories are an essential component of animal disease surveillance systems. To understand the occurrence of disease in populations, surveillance systems rely on random or targeted surveys using three approaches: clinical, serological and virological surveillance. Clinical surveillance is the basis for early detection of disease and is usually centered on the detection of syndromes and clinical findings requiring confirmation by diagnostic laboratories. Although most of the tests applied usually perform to an acceptable standard, several have not been properly validated in terms of their diagnostic sensitivity and specificity. Sensitivity and specificity estimates can vary according to local conditions and, ideally, should be determined by national laboratories where the tests are to be applied. The importance of sensitivity and specificity estimates in the design and interpretation of statistically based surveys and risk analysis is fundamental to establish appropriate disease control and prevention strategies. The World Organisation for Animal Health's (OIE) network of reference laboratories acts as centers of expertise for the diagnosis of OIE listed diseases and have a role in promoting the validation of OIE prescribed tests for international trade. This paper discusses the importance of the epidemiological evaluation of diagnostic tests and the role of the OIE Reference Laboratories and Collaborating Centres in this process.

  9. An overview of the roles and structure of international high-security veterinary laboratories for infectious animal diseases.

    PubMed

    Murray, P K

    1998-08-01

    The unique structure, role and operations of government high-security (HS) laboratories which work on animal diseases are described, with particular reference to the laboratories of nine countries. High-security laboratories provide cost-effective insurance against catastrophic losses which could occur following exotic disease outbreaks. The importance of these laboratories is reflected in the fact that several new laboratories have recently been constructed at considerable expense and older facilities have undergone major renovations. Biosecurity is fundamental to the operation of high-security laboratories, so good facility design and microbiological security practices are very important. High-security laboratories conduct exotic disease diagnosis, certification and surveillance, and also perform research into virology, disease pathogenesis and improvements to diagnostic tests and vaccines. The mandate of these laboratories includes the training of veterinarians in the recognition of exotic diseases. One extremely important role is the provision of expert advice on exotic diseases and participation (both nationally and internationally) in policy decisions regarding animal disease issues.

  10. The OIE World Animal Health Information System: the role of OIE Reference Laboratories and Collaborating Centres in disease reporting.

    PubMed

    Ben Jebara, K

    2010-12-01

    One of the main objectives of the World Organisation for Animal Health (OIE) is to ensure transparency in and knowledge of the world animal health situation. To achieve this objective, the OIE relies on its network of Member Countries, which is complemented by the activities of 221 Reference Laboratories (RLs) and Collaborating Centres. The RL mandate states that, in the case of positive results for diseases notifiable to the OIE, the laboratory should inform the OIE Delegate of the Member Country from which the samples originated and send a copy of the information to OIE Headquarters. However, since 2006 the OIE has received a lower than expected number of notifications from RLs, which implies eitherthat the majority of samples are sent to national laboratories or that some RLs are not fully complying with their mandate. The OIE sent a questionnaire to RLs in preparation for the Second Global Conference of OIE Reference Laboratories and Collaborating Centres (Paris, France, 21-23 June 2010). Two main factors emerged: the need for RLs to clarify their role and responsibilities in disease reporting and the need for an awareness campaign to sensitise national Veterinary Services to the importance of conducting more surveillance (and consequently of submitting samples to RLs) for all OIE-listed diseases. Reference laboratories indicated two main reasons for not sharing more data on positive samples with the OIE: i) a perceived contradiction between their mandate as OIE RLs and the standards of the International Organization for Standardization (ISO) dealing with confidentiality; and ii) certain Member Countries or stakeholders asking RLs not to share positive results with the OIE, for political or economic reasons. The OIE has put forward proposals to help RLs resolve these problems in future. The use of ISO standards must be clarified and there must be improved communication between the OIE and its RLs. A lack of transparency about a significant disease event can jeopardise the biosecurity of several countries, an entire region or even the whole world. The reference status of a non-transparent RL could be questioned.

  11. Hematological reference values of healthy Malaysian population.

    PubMed

    Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N

    2009-10-01

    Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.

  12. [SWOT analysis of laboratory certification and accreditation on detection of parasitic diseases].

    PubMed

    Xiong, Yan-hong; Zheng, Bin

    2014-04-01

    This study analyzes the strength, weakness, opportunity and threat (SWOT) of laboratory certification and accreditation on detection of parasitic diseases by SWOT analysis comprehensively, and it puts forward some development strategies specifically, in order to provide some indicative references for the further development.

  13. How Can We Identify the Elimination of Infectious Diseases? Experience From an Active Measles Laboratory Surveillance System in the Republic of Korea.

    PubMed

    Yang, Tae Un; Kang, Hae Ji; Eom, Hye Eun; Park, Young-Joon; Park, Ok; Kim, Su Jin; Nam, Jeong-Gu; Kim, Sung Soon; Jeong, Eun Kyeong

    2015-11-01

    Global efforts have markedly decreased the disease burden of vaccine-preventable diseases. Many countries have made considerable progress toward the elimination of measles. As elimination is approached, the very low incidence achieved by high vaccination coverage has underscored the need for a sensitive and timely surveillance system. In the Republic of Korea, an active laboratory surveillance system (ALSS) was implemented to supplement the existing passive surveillance system in 2006. The ALSS connects 5 major commercial laboratories and the national measles reference laboratory, where referred samples with positive or equivocal results are retested. Annually, from 2009 to 2013, 3714 suspected cases were detected through the ALSS, an expansion of 8- to 57-fold, compared with only the passive surveillance system. The ALSS, with its sensitivity and timeliness, is a reasonable strategy to supplement the existing measles surveillance system and to help identify the elimination of measles. © 2015 APJPH.

  14. Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females

    PubMed Central

    Ryden, Ingvar; Lind, Lars

    2012-01-01

    Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333

  15. The Naval Health Research Center Respiratory Disease Laboratory.

    PubMed

    Ryan, M; Gray, G; Hawksworth, A; Malasig, M; Hudspeth, M; Poddar, S

    2000-07-01

    Concern about emerging and reemerging respiratory pathogens prompted the development of a respiratory disease reference laboratory at the Naval Health Research Center. Professionals working in this laboratory have instituted population-based surveillance for pathogens that affect military trainees and responded to threats of increased respiratory disease among high-risk military groups. Capabilities of this laboratory that are unique within the Department of Defense include adenovirus testing by viral shell culture and microneutralization serotyping, influenza culture and hemagglutination inhibition serotyping, and other special testing for Streptococcus pneumoniae, Streptococcus pyogenes, Mycoplasma pneumonia, and Chlamydia pneumoniae. Projected capabilities of this laboratory include more advanced testing for these pathogens and testing for other emerging pathogens, including Bordetella pertussis, Legionella pneumoniae, and Haemophilus influenzae type B. Such capabilities make the laboratory a valuable resource for military public health.

  16. Burkholderia pseudomallei: Challenges for the Clinical Microbiology Laboratory.

    PubMed

    Hemarajata, Peera; Baghdadi, Jonathan D; Hoffman, Risa; Humphries, Romney M

    2016-12-01

    Melioidosis is a potentially fatal infection caused by the bacterium Burkholderia pseudomallei Clinical diagnosis of melioidosis can be challenging since there is no pathognomonic clinical syndrome, and the organism is often misidentified by methods used routinely in clinical laboratories. Although the disease is more prevalent in Thailand and northern Australia, sporadic cases may be encountered in areas where it is not endemic, including the United States. Since the organism is considered a tier 1 select agent according to the Centers for Disease Control and Prevention and the U.S. Department of Agriculture Animal and Plant Health Inspection Service, clinical laboratories must be proficient at rapidly recognizing isolates suspicious for B. pseudomallei, be able to safely perform necessary rule-out tests, and to refer suspect isolates to Laboratory Response Network reference laboratories. In this minireview, we report a case of melioidosis encountered at our institution and discuss the laboratory challenges encountered when dealing with clinical isolates suspicious for B. pseudomallei or clinical specimens from suspected melioidosis cases. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  17. [Comparison of serological procedures used for the diagnosis of viral exanthema in laboratories participating in the measles elimination plan].

    PubMed

    de Ory, Fernando; Sanz, Juan Carlos; Echevarría, Juan Emilio; Mosquera, María del Mar; Guisasola, María Eulalia

    2004-01-01

    The comparison of serological methods used by the laboratories participating in the Network for the Elimination of Measles to diagnose measles virus infection as well as differential diagnosis with other exanthematic diseases are compared. One panel of 20 serum samples including measles (12), rubella (4), parvovirus B19 (2) and dengue (2) infections was established. All cases were diagnosed by detection of specific IgM. The panel was sent to the laboratories of the Network. The results were compared with those obtained at the reference laboratory. Regarding measles, IgM response from 20 laboratories (19 by ELISA and 1 by indirect immunofluorescence) was obtained, with an agreement of 91.5%. Related to rubella IgM, replay from 6 laboratories, using ELISA, was received, with an agreement of 98.7%. With respect to parvovirus B19 IgM, response from 10 laboratories (8 by ELISA and 2 by indirect immunofluorescence) was obtained, with an agreement of 94.6%. Results about dengue virus were not reported by any laboratory. Some laboratories from the network should review the methods used for the diagnosis of measles and other exanthematic diseases. The results reassert the need for a reference laboratory to support confirmation of the results.

  18. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    PubMed

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  19. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2017-01-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) −1.292 (n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was −0.71%, −0.42% and −0.13%, respectively. For the combined precision, the equation y (CV) = −0.398 × (triglycerides value) + 1.797 (n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time. PMID:26680645

  20. Performance of serological tests for syphilis in sexually transmitted diseases clinics in Guangxi Autonomous Region, China: implications for syphilis surveillance and control.

    PubMed

    Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S

    2009-03-01

    China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.

  1. [The National Reference Centres and Reference Laboratories. Importance and tasks].

    PubMed

    Laude, G; Ammon, A

    2005-09-01

    Since 1995, the German Federal Ministry for Health and Social Security funds National Reference Centres (NRC) for the laboratory surveillance of important pathogens and syndromes. Which pathogens or syndromes are selected to be covered by a NRC depends on their epidemiological relevance, the special diagnostic tools, problems with antimicrobial resistance and necessary infection control measures. Currently, there are 15 NRC, which are appointed for a period of 3 years (currently from January 2005 through December 2007). Towards the end of their appointment all NRC are evaluated by a group of specialists. The assessment of their achievements is guided by a catalogue of tasks for the NRC. In addition to the NRC, a total of 50 laboratories are appointed which provide specialist expertise for additional pathogens in order to have a broad range of pathogens for which specialist laboratories are available. Their predominant task is to give advice and support for special diagnostic problems. Both NRC and the specialist laboratories are important parts of the network for infectious disease epidemiology.

  2. [Microbiological Surveillance of Measles and Rubella in Spain. Laboratory Network].

    PubMed

    Echevarría, Juan Emilio; Fernández García, Aurora; de Ory, Fernando

    2015-01-01

    The Laboratory is a fundamental component on the surveillance of measles and rubella. Cases need to be properly confirmed to ensure an accurate estimation of the incidence. Strains should be genetically characterized to know the transmission pattern of these viruses and frequently, outbreaks and transmission chains can be totally discriminated only after that. Finally, the susceptibility of the population is estimated on the basis of sero-prevalence surveys. Detection of specific IgM response is the base of the laboratory diagnosis of these diseases. It should be completed with genomic detection by RT-PCR to reach an optimal efficiency, especially when sampling is performed early in the course of the disease. Genotyping is performed by genomic sequencing according to reference protocols of the WHO. Laboratory surveillance of measles and rubella in Spain is organized as a net of regional laboratories with different capabilities. The National Center of Microbiology as National Reference Laboratory (NRL), supports regional laboratories ensuring the availability of all required techniques in the whole country and watching for the quality of the results. The NRL is currently working in the implementation of new molecular techniques based on the analysis of genomic hypervariable regions for the strain characterization at sub-genotypic levels and use them in the surveillance.

  3. Laboratory capacity for diagnosis of foot-and-mouth disease in Eastern Africa: implications for the progressive control pathway.

    PubMed

    Namatovu, Alice; Wekesa, Sabenzia Nabalayo; Tjørnehøj, Kirsten; Dhikusooka, Moses Tefula; Muwanika, Vincent B; Siegsmund, Hans Redlef; Ayebazibwe, Chrisostom

    2013-01-24

    Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006-2010. The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples.

  4. Laboratory capacity for diagnosis of foot-and-mouth disease in Eastern Africa: implications for the progressive control pathway

    PubMed Central

    2013-01-01

    Background Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006–2010. Results The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. Conclusions This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples. PMID:23347795

  5. Clinical symptoms and laboratory findings supporting early diagnosis of Crimean-Congo hemorrhagic fever in Iran.

    PubMed

    Mostafavi, Ehsan; Pourhossein, Behzad; Chinikar, Sadegh

    2014-07-01

    Crimean-Congo hemorrhagic fever (CCHF) is a zoonotic disease, which is usually transmitted to humans by tick bites or contact with blood or other infected tissues of livestock. Patients suffering from CCHF demonstrate an extensive spectrum of clinical symptoms. As it can take considerable time from suspecting the disease in hospital until reaching a definitive diagnosis in the laboratory, understanding the clinical symptoms and laboratory findings of CCHF patients is of paramount importance for clinicians. The data were collected from patients who were referred to the Laboratory of Arboviruses and Viral Hemorrhagic Fevers at the Pasteur institute of Iran with a primary diagnosis of CCHF between 1999 and 2012 and were assessed by molecular and serologic tests. Referred patients were divided into two groups: patients with a CCHF positive result and patients with a CCHF negative result. The laboratory and clinical findings of these two groups were then compared. Two-thousand five hundred thirty-six probable cases of CCHF were referred to the laboratory, of which 871 cases (34.3%) were confirmed to be CCHF. Contact with infected humans and animals increased the CCHF infection risk (P < 0.001). A tick bite was not a risk factor. Fever; bleeding, vomiting, leucopoenia, thrombocytopenia, and increases in alanine transaminase (ALT) and aspartate transaminase (AST) levels were also indicative of CCHF infection. Accurate and speedy diagnosis of CCHF and appropriate treatment play an important role in patient survival and the application of the findings of this study can prove helpful as a key for early diagnosis. © 2014 Wiley Periodicals, Inc.

  6. Underreporting of viral encephalitis and viral meningitis, Ireland, 2005-2008.

    PubMed

    Kelly, Tara A; O'Lorcain, Piaras; Moran, Joanne; Garvey, Patricia; McKeown, Paul; Connell, Jeff; Cotter, Suzanne

    2013-01-01

    Viral encephalitis (VE) and viral meningitis (VM) have been notifiable infectious diseases under surveillance in the Republic of Ireland since 1981. Laboratories have reported confirmed cases by detection of viral nucleic acid in cerebrospinal fluid since 2004. To determine the prevalence of these diseases in Ireland during 2005-2008, we analyzed 3 data sources: Hospital In-patient Enquiry data (from hospitalized following patients discharge) accessed through Health Intelligence Ireland, laboratory confirmations from the National Virus Reference Laboratory, and events from the Computerised Infectious Disease Reporting surveillance system. We found that the national surveillance system underestimates the incidence of these diseases in Ireland with a 10-fold higher VE hospitalization rate and 3-fold higher VM hospitalization rate than the reporting rate. Herpesviruses were responsible for most specified VE and enteroviruses for most specified VM from all 3 sources. Recommendations from this study have been implemented to improve the surveillance of these diseases in Ireland.

  7. SENIORLAB: a prospective observational study investigating laboratory parameters and their reference intervals in the elderly.

    PubMed

    Risch, Martin; Nydegger, Urs; Risch, Lorenz

    2017-01-01

    In clinical practice, laboratory results are often important for making diagnostic, therapeutic, and prognostic decisions. Interpreting individual results relies on accurate reference intervals and decision limits. Despite the considerable amount of resources in clinical medicine spent on elderly patients, accurate reference intervals for the elderly are rarely available. The SENIORLAB study set out to determine reference intervals in the elderly by investigating a large variety of laboratory parameters in clinical chemistry, hematology, and immunology. The SENIORLAB study is an observational, prospective cohort study. Subjectively healthy residents of Switzerland aged 60 years and older were included for baseline examination (n = 1467), where anthropometric measurements were taken, medical history was reviewed, and a fasting blood sample was drawn under optimal preanalytical conditions. More than 110 laboratory parameters were measured, and a biobank was set up. The study participants are followed up every 3 to 5 years for quality of life, morbidity, and mortality. The primary aim is to evaluate different laboratory parameters at age-related reference intervals. The secondary aims of this study include the following: identify associations between different parameters, identify diagnostic characteristics to diagnose different circumstances, identify the prevalence of occult disease in subjectively healthy individuals, and identify the prognostic factors for the investigated outcomes, including mortality. To obtain better grounds to justify clinical decisions, specific reference intervals for laboratory parameters of the elderly are needed. Reference intervals are obtained from healthy individuals. A major obstacle when obtaining reference intervals in the elderly is the definition of health in seniors because individuals without any medical condition and any medication are rare in older adulthood. Reference intervals obtained from such individuals cannot be considered representative for seniors in a status of age-specific normal health. In addition to the established methods for determining reference intervals, this longitudinal study utilizes a unique approach, in that survival and long-term well-being are taken as indicators of health in seniors. This approach is expected to provide robust and representative reference intervals that are obtained from an adequate reference population and not a collective of highly selected individuals. The present study was registered under International Standard Randomized Controlled Trial Number registry: ISRCTN53778569.

  8. Role of congenital rubella reference laboratory: 21-months-surveillance in Liguria, Italy.

    PubMed

    Canepa, P; Valle, L; Cristina, E; De Florentiis, D; Parodi, V; Banfi, F; Zancolli, M; Durando, P; Icardi, G; Ansaldi, F

    2009-12-01

    Rubella is generally a mild rush fever disease when acquired in childhood, but when infection occurs during the first months of pregnancy, high risk of trans-placental transmission to the foetus and of congenital anomalies exists. In November 2003, a National Plan for measles and congenital rubella elimination was approved in Italy. The aim was to reduce and maintain Congenital Rubella Syndrome incidence lower than 1 case per 100,000 live births/year by 2007. Since June 2006, Liguria Administrative Region recognized U.O. Hygiene, "San Martino" University Hospital, Genoa, as regional reference laboratory for diagnosis of rubella infection during pregnancy and post-partum. Twenty-one-month virological-surveillance results between April 2007 and December 2008 were reported in terms of demographic data, risk factors, access reasons, clinical picture, vaccination, previous rubella disease, laboratory results of pregnant women and newborns. Since the beginning of surveillance, 65 pregnant women with suspected virus infection and 18 newborns with suspected congenital rubella were followed up. The results of laboratory surveillance highlighted (i) the importance of an early screening, (ii) the suboptimal specificity of chemiluminescent assays, that often yield false positive IgM results and (iii) the fundamental role of second-level laboratory to confirm the serological diagnosis and to detect the virus by molecular techniques.

  9. Genetics Home Reference: von Willebrand disease

    MedlinePlus

    ... PubMed Nichols WL, Hultin MB, James AH, Manco-Johnson MJ, Montgomery RR, Ortel TL, Rick ME, Sadler ... JE, Yawn BP, James AH, Hultin MB, Manco-Johnson MJ, Weinstein M. Clinical and laboratory diagnosis of ...

  10. Hematology and biochemistry reference intervals for Ontario commercial nursing pigs close to the time of weaning

    PubMed Central

    Perri, Amanda M.; O’Sullivan, Terri L.; Harding, John C.S.; Wood, R. Darren; Friendship, Robert M.

    2017-01-01

    The evaluation of pig hematology and biochemistry parameters is rarely done largely due to the costs associated with laboratory testing and labor, and the limited availability of reference intervals needed for interpretation. Within-herd and between-herd biological variation of these values also make it difficult to establish reference intervals. Regardless, baseline reference intervals are important to aid veterinarians in the interpretation of blood parameters for the diagnosis and treatment of diseased swine. The objective of this research was to provide reference intervals for hematology and biochemistry parameters of 3-week-old commercial nursing piglets in Ontario. A total of 1032 pigs lacking clinical signs of disease from 20 swine farms were sampled for hematology and iron panel evaluation, with biochemistry analysis performed on a subset of 189 randomly selected pigs. The 95% reference interval, mean, median, range, and 90% confidence intervals were calculated for each parameter. PMID:28373729

  11. Syphilis testing practices in the Americas.

    PubMed

    Trinh, Thuy T; Kamb, Mary L; Luu, Minh; Ham, D Cal; Perez, Freddy

    2017-09-01

    To present the findings of the Pan American Health Organization's 2014 survey on syphilis testing policies and practices in the Americas. Representatives of national/regional reference and large, lower-level laboratories from 35 member states were invited to participate. A semi-structured, electronically administered questionnaire collected data on syphilis tests, algorithms, equipment/commodities, challenges faced and basic quality assurance (QA) strategies employed (i.e. daily controls, standard operating procedures, technician training, participating in external QA programmes, on-site evaluations). The 69 participating laboratories from 30 (86%) member states included 41 (59%) national/regional reference and 28 (41%) lower-level laboratories. Common syphilis tests conducted were the rapid plasma reagin (RPR) (62% of surveyed laboratories), venereal disease research laboratory (VDRL) (54%), fluorescent treponemal antibody absorption (FTA-ABS) (41%) and Treponema pallidum haemagglutination assay (TPHA) (32%). Only three facilities reported using direct detection methods, and 28 (41% overall, 32% of lower-level facilities) used rapid tests. Most laboratories (62%) used only traditional testing algorithms (non-treponemal screening and treponemal confirmatory testing); however, 12% used only a reverse sequence algorithm (treponemal test first), and 14% employed both algorithms. Another nine (12%) laboratories conducted only one type of serologic test. Although most reference (97%) and lower-level (89%) laboratories used at least one QA strategy, only 16% reported using all five basic strategies. Commonly reported challenges were stock-outs of essential reagents or commodities (46%), limited staff training (73%) and insufficient equipment (39%). Many reference and clinical laboratories in the Americas face challenges in conducting appropriate syphilis testing and in ensuring quality of testing. © 2017 John Wiley & Sons Ltd The Pan-American Health Organization retains copyright and all other rights in the manuscript of this article as submitted for publication.

  12. Underreporting of Viral Encephalitis and Viral Meningitis, Ireland, 2005–2008

    PubMed Central

    O’Lorcain, Piaras; Moran, Joanne; Garvey, Patricia; McKeown, Paul; Connell, Jeff; Cotter, Suzanne

    2013-01-01

    Viral encephalitis (VE) and viral meningitis (VM) have been notifiable infectious diseases under surveillance in the Republic of Ireland since 1981. Laboratories have reported confirmed cases by detection of viral nucleic acid in cerebrospinal fluid since 2004. To determine the prevalence of these diseases in Ireland during 2005–2008, we analyzed 3 data sources: Hospital In-patient Enquiry data (from hospitalized following patients discharge) accessed through Health Intelligence Ireland, laboratory confirmations from the National Virus Reference Laboratory, and events from the Computerised Infectious Disease Reporting surveillance system. We found that the national surveillance system underestimates the incidence of these diseases in Ireland with a 10-fold higher VE hospitalization rate and 3-fold higher VM hospitalization rate than the reporting rate. Herpesviruses were responsible for most specified VE and enteroviruses for most specified VM from all 3 sources. Recommendations from this study have been implemented to improve the surveillance of these diseases in Ireland. PMID:23965781

  13. 42 CFR 7.1 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.1 Applicability. The provisions of this part are applicable to private entities requesting from the Centers for Disease Control (CDC) reference biological standards and biological preparations for use in their laboratories. ...

  14. 42 CFR 7.1 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.1 Applicability. The provisions of this part are applicable to private entities requesting from the Centers for Disease Control (CDC) reference biological standards and biological preparations for use in their laboratories. ...

  15. 42 CFR 7.1 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.1 Applicability. The provisions of this part are applicable to private entities requesting from the Centers for Disease Control (CDC) reference biological standards and biological preparations for use in their laboratories. ...

  16. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    PubMed Central

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty; Dumoulin, Christine; Ramos-Arroyo, Maria; Biunno, Ida; Bauer, Peter; Kline, Margaret; Landwehrmeyer, G Bernhard

    2012-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original results from 121 laboratories across 15 countries. We report on 1326 duplicate results; a discrepancy in reporting the upper allele occurred in 51% of cases, this reduced to 13.3% and 9.7% when we applied acceptable measurement errors proposed by the American College of Medical Genetics and the Draft European Best Practice Guidelines, respectively. Duplicate results were available for 1250 lower alleles; discrepancies occurred in 40% of cases. Clinically significant discrepancies occurred in 4.0% of cases with a potential unexplained misdiagnosis rate of 0.3%. There was considerable variation in the discrepancy rate among 10 of the countries participating in this study. Out of 1326 samples, 348 were re-analysed by an accredited diagnostic laboratory, based in Germany, with concordance rates of 93% and 94% for the upper and lower alleles, respectively. This became 100% if the acceptable measurement errors were applied. The central laboratory correctly reported allele sizes for six standard reference samples, blind to the known result. Our study differs from external quality assessment (EQA) schemes in that these are duplicate results obtained from a large sample of patients across the whole diagnostic range. We strongly recommend that laboratories state an error rate for their measurement on the report, participate in EQA schemes and use reference materials regularly to adjust their own internal standards. PMID:21811303

  17. National Biocontainment Training Center

    DTIC Science & Technology

    2016-10-01

    and the high containment capabilities of the Galveston National Laboratory. U.S. Food and Drug Administration Training – Marisa Hickey, D.V.M., MPH...in the Netherlands focused specifically on “healthy food and healthy environment.” The CVI is the national reference laboratory that is focused on...the health of both animals and humans. They provide research for government and commercial entities on animal diseases that threaten the food supply

  18. PFGE standard operating procedures for Listeria monocytogenes: harmonizing the typing of food and clinical strains in Europe.

    PubMed

    Michelon, Damien; Félix, Benjamin; Vingadassalon, Noemie; Mariet, Jean-François; Larsson, Jonas T; Møller-Nielsen, Eva; Roussel, Sophie

    2015-03-01

    Listeria monocytogenes is a foodborne pathogen responsible for a severe disease known as listeriosis. The European Centre for Disease Prevention and Control (ECDC) coordinates a network of national public health laboratories (NPHLs) in charge of typing clinical strains. In food, it is the European Union Reference Laboratory for L. monocytogenes (EURL Lm), which manages a network of National Reference Laboratories (NRLs). A pulsed-field gel electrophoresis (PFGE) standard operating procedure (EURL SOP) has been used routinely at the EURL Lm since 2007. The EURL Lm has recommended that NRLs use the EURL SOP, whereas the Statens Serum Institut (SSI), under contract for ECDC, requested that NPHLs use Halpins' SOP (HSOP) published in 2010 for the PulseNet USA network. An update of Halpins' SOP (uHSOP) was published in 2013. To facilitate the exchange of profiles among human and food European reference laboratories, it is crucial to ensure that the PFGE profiles obtained with these different SOPs are comparable. The aim here was to compare the EURL SOP with HSOP and uHSOP. The panel comprised 114 well-characterized SSI/EURL strains. All were characterized at the EURL using both the EURL SOP and uHSOP. Seventy of the 114 strains were also characterized at the SSI using HSOP. The EURL SOP and uHSOP produced indistinguishable combined (ApaI/AscI) profiles for the 114 strains tested. The EURL SOP and HSOP produced indistinguishable combined profiles for 69 of the 70 strains tested. One strain displayed for the AscI profile an additional low-intensity band at 184 kbp with HSOP. For this strain, SSI and EUR Lm had already observed the same profile from NPHLs and NRLs. However, this deviation is minor as it accounted for about 1% of all the 114 combined profiles. This study should facilitate the exchange of reproducible PFGE profiles among human and food reference laboratories.

  19. Laboratory diagnostics of chronic kidney disease in Croatia: state of the art

    PubMed Central

    Honović, Lorena; Matica, Jasminka; Knežević, Branka; Vojak, Sanela Šimić

    2015-01-01

    Introduction Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia. Materials and methods An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions. Results The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein. Conclusions There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia. PMID:25672470

  20. Strengthening systems for communicable disease surveillance: creating a laboratory network in Rwanda

    PubMed Central

    2011-01-01

    Background The recent emergence of a novel strain of influenza virus with pandemic potential underscores the need for quality surveillance and laboratory services to contribute to the timely detection and confirmation of public health threats. To provide a framework for strengthening disease surveillance and response capacities in African countries, the World Health Organization Regional Headquarters for Africa (AFRO) developed Integrated Disease Surveillance and Response (IDSR) aimed at improving national surveillance and laboratory systems. IDSR emphasizes the linkage of information provided by public health laboratories to the selection of relevant, appropriate and effective public health responses to disease outbreaks. Methods We reviewed the development of Rwanda's National Reference Laboratory (NRL) to understand essential structures involved in creating a national public health laboratory network. We reviewed documents describing the NRL's organization and record of test results, conducted site visits, and interviewed health staff in the Ministry of Health and in partner agencies. Findings were developed by organizing thematic categories and grouping examples within them. We purposefully sought to identify success factors as well as challenges inherent in developing a national public health laboratory system. Results Among the identified success factors were: a structured governing framework for public health surveillance; political commitment to promote leadership for stronger laboratory capacities in Rwanda; defined roles and responsibilities for each level; coordinated approaches between technical and funding partners; collaboration with external laboratories; and use of performance results in advocacy with national stakeholders. Major challenges involved general infrastructure, human resources, and budgetary constraints. Conclusions Rwanda's experience with collaborative partnerships contributed to creation of a functional public health laboratory network. PMID:21702948

  1. U.S. Army Medical Research Institute of Infectious Diseases

    MedlinePlus

    ... Health Organization. As a reference laboratory for the Department of Defense, we set the standard for identification of biological agents. Our customers in the Army and the Department of Defense know us as a "tech base" organization that ...

  2. Trueness and precision of the real-time RT-PCR method for quantifying the chronic bee paralysis virus genome in bee homogenates evaluated by a comparative inter-laboratory study.

    PubMed

    Schurr, Frank; Cougoule, Nicolas; Rivière, Marie-Pierre; Ribière-Chabert, Magali; Achour, Hamid; Ádám, Dán; Castillo, Carlos; de Graaf, Dirk C; Forsgren, Eva; Granato, Anna; Heinikainen, Sirpa; Jurovčíková, Júlia; Kryger, Per; Manson, Christine; Ménard, Marie-Françoise; Perennes, Stéphane; Schäfer, Marc O; Ibañez, Elena San Miguel; Silva, João; Gajger, Ivana Tlak; Tomkies, Victoria; Toplak, Ivan; Viry, Alain; Zdańska, Dagmara; Dubois, Eric

    2017-10-01

    The Chronic bee paralysis virus (CBPV) is the aetiological agent of chronic bee paralysis, a contagious disease associated with nervous disorders in adult honeybees leading to massive mortalities in front of the hives. Some of the clinical signs frequently reported, such as trembling, may be confused with intoxication syndromes. Therefore, laboratory diagnosis using real-time PCR to quantify CBPV loads is used to confirm disease. Clinical signs of chronic paralysis are usually associated with viral loads higher than 10 8 copies of CBPV genome copies per bee (8 log 10 CBPV/bee). This threshold is used by the European Union Reference Laboratory for Bee Health to diagnose the disease. In 2015, the accuracy of measurements of three CBPV loads (5, 8 and 9 log 10 CBPV/bee) was assessed through an inter-laboratory study. Twenty-one participants, including 16 European National Reference Laboratories, received 13 homogenates of CBPV-infected bees adjusted to the three loads. Participants were requested to use the method usually employed for routine diagnosis. The quantitative results (n=270) were analysed according to international standards NF ISO 13528 (2015) and NF ISO 5725-2 (1994). The standard deviations of measurement reproducibility (S R ) were 0.83, 1.06 and 1.16 at viral loads 5, 8 and 9 log 10 CBPV/bee, respectively. The inter-laboratory confidence of viral quantification (+/- 1.96S R ) at the diagnostic threshold (8 log 10 CBPV/bee) was+/- 2.08 log 10 CBPV/bee. These results highlight the need to take into account the confidence of measurements in epidemiological studies using results from different laboratories. Considering this confidence, viral loads over 6 log 10 CBPV/bee may be considered to indicate probable cases of chronic paralysis. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Development of an algorithm for production of inactivated arbovirus antigens in cell culture

    PubMed Central

    Goodman, C.H.; Russell, B.J.; Velez, J.O.; Laven, J.J.; Nicholson, W.L; Bagarozzi, D.A.; Moon, J.L.; Bedi, K.; Johnson, B.W.

    2015-01-01

    Arboviruses are medically important pathogens that cause human disease ranging from a mild fever to encephalitis. Laboratory diagnosis is essential to differentiate arbovirus infections from other pathogens with similar clinical manifestations. The Arboviral Diseases Branch (ADB) reference laboratory at the CDC Division of Vector-Borne Diseases (DVBD) produces reference antigens used in serological assays such as the virus-specific immunoglobulin M antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA). Antigen production in cell culture has largely replaced the use of suckling mice; however, the methods are not directly transferable. The development of a cell culture antigen production algorithm for nine arboviruses from the three main arbovirus families, Flaviviridae, Togaviridae, and Bunyaviridae, is described here. Virus cell culture growth and harvest conditions were optimized, inactivation methods were evaluated, and concentration procedures were compared for each virus. Antigen performance was evaluated by the MAC-ELISA at each step of the procedure. The antigen production algorithm is a framework for standardization of methodology and quality control; however, a single antigen production protocol was not applicable to all arboviruses and needed to be optimized for each virus. PMID:25102428

  4. The laboratory diagnosis of syphilis.

    PubMed

    Ratnam, Sam

    2005-01-01

    Syphilis has several clinical manifestations, making laboratory testing a very important aspect of diagnosis. In North America, many unsuspected cases are discovered by laboratory testing. The etiological agent, Treponema pallidum, cannot be cultured, and there is no single optimal alternative test. Serological testing is the most frequently used approach in the laboratory diagnosis of syphilis. The present paper discusses the various serological and alternative tests currently available along with their limitations, and relates their results to the likely corresponding clinical stage of the disease. The need to use multiple tests is discussed, and the importance of quality control is noted. The complexity of syphilis serology means that the services of reference laboratories and clinical experts are often needed.

  5. Clinical Investigation Program. Annual Progress Report. Volume 1

    DTIC Science & Technology

    1994-01-20

    Suport Labs Resch Chemist 13 0644 GS Salata, KF Allergy Microbiologist 12 0403 CS Billups, L Flow Cytom Microbiologist 12 0403 GS Dobek, AS Inf Disease 5...continued to increase laboratory research support to principal investigators throughout the medical center. The DCI Flow Cytometry Laboratory provided...Kalman PhD. Mitogen-Inducible T Suppressor Cell 12 Assay by Flow Cytometry (12/89) * Reference is to page number(s) in Volume II. 30 PROTOCOL NUMBER

  6. 42 CFR 7.1 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.1 Applicability. The provisions of this part are applicable to private entities requesting from the Centers for Disease Control and Prevention (CDC) reference biological Standards and Biological preparations for use in their laboratories. [78 FR 43820, July 22, 2013] ...

  7. 42 CFR 7.1 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BIOLOGICAL STANDARDS AND BIOLOGICAL PREPARATIONS § 7.1 Applicability. The provisions of this part are applicable to private entities requesting from the Centers for Disease Control and Prevention (CDC) reference biological Standards and Biological preparations for use in their laboratories. [78 FR 43820, July 22, 2013] ...

  8. Capacity-building efforts by the AFHSC-GEIS program.

    PubMed

    Sanchez, Jose L; Johns, Matthew C; Burke, Ronald L; Vest, Kelly G; Fukuda, Mark M; Yoon, In-Kyu; Lon, Chanthap; Quintana, Miguel; Schnabel, David C; Pimentel, Guillermo; Mansour, Moustafa; Tobias, Steven; Montgomery, Joel M; Gray, Gregory C; Saylors, Karen; Ndip, Lucy M; Lewis, Sheri; Blair, Patrick J; Sjoberg, Paul A; Kuschner, Robert A; Russell, Kevin L; Blazes, David L; Witt, Clara J; Money, Nisha N; Gaydos, Joel C; Pavlin, Julie A; Gibbons, Robert V; Jarman, Richard G; Stoner, Mikal; Shrestha, Sanjaya K; Owens, Angela B; Iioshi, Naomi; Osuna, Miguel A; Martin, Samuel K; Gordon, Scott W; Bulimo, Wallace D; Waitumbi, Dr John; Assefa, Berhane; Tjaden, Jeffrey A; Earhart, Kenneth C; Kasper, Matthew R; Brice, Gary T; Rogers, William O; Kochel, Tadeusz; Laguna-Torres, Victor Alberto; Garcia, Josefina; Baker, Whitney; Wolfe, Nathan; Tamoufe, Ubald; Djoko, Cyrille F; Fair, Joseph N; Akoachere, Jane Francis; Feighner, Brian; Hawksworth, Anthony; Myers, Christopher A; Courtney, William G; Macintosh, Victor A; Gibbons, Thomas; Macias, Elizabeth A; Grogl, Max; O'Neil, Michael T; Lyons, Arthur G; Houng, Huo-Shu; Rueda, Leopoldo; Mattero, Anita; Sekonde, Edward; Sang, Rosemary; Sang, William; Palys, Thomas J; Jerke, Kurt H; Millard, Monica; Erima, Bernard; Mimbe, Derrick; Byarugaba, Denis; Wabwire-Mangen, Fred; Shiau, Danny; Wells, Natalie; Bacon, David; Misinzo, Gerald; Kulanga, Chesnodi; Haverkamp, Geert; Kohi, Yadon Mtarima; Brown, Matthew L; Klein, Terry A; Meyers, Mitchell; Schoepp, Randall J; Norwood, David A; Cooper, Michael J; Maza, John P; Reeves, William E; Guan, Jian

    2011-03-04

    Capacity-building initiatives related to public health are defined as developing laboratory infrastructure, strengthening host-country disease surveillance initiatives, transferring technical expertise and training personnel. These initiatives represented a major piece of the Armed Forces Health Surveillance Center, Division of Global Emerging Infections Surveillance and Response System (AFHSC-GEIS) contributions to worldwide emerging infectious disease (EID) surveillance and response. Capacity-building initiatives were undertaken with over 80 local and regional Ministries of Health, Agriculture and Defense, as well as other government entities and institutions worldwide. The efforts supported at least 52 national influenza centers and other country-specific influenza, regional and U.S.-based EID reference laboratories (44 civilian, eight military) in 46 countries worldwide. Equally important, reference testing, laboratory infrastructure and equipment support was provided to over 500 field sites in 74 countries worldwide from October 2008 to September 2009. These activities allowed countries to better meet the milestones of implementation of the 2005 International Health Regulations and complemented many initiatives undertaken by other U.S. government agencies, such as the U.S. Department of Health and Human Services, the U.S. Agency for International Development and the U.S. Department of State.

  9. Capacity-building efforts by the AFHSC-GEIS program

    PubMed Central

    2011-01-01

    Capacity-building initiatives related to public health are defined as developing laboratory infrastructure, strengthening host-country disease surveillance initiatives, transferring technical expertise and training personnel. These initiatives represented a major piece of the Armed Forces Health Surveillance Center, Division of Global Emerging Infections Surveillance and Response System (AFHSC-GEIS) contributions to worldwide emerging infectious disease (EID) surveillance and response. Capacity-building initiatives were undertaken with over 80 local and regional Ministries of Health, Agriculture and Defense, as well as other government entities and institutions worldwide. The efforts supported at least 52 national influenza centers and other country-specific influenza, regional and U.S.-based EID reference laboratories (44 civilian, eight military) in 46 countries worldwide. Equally important, reference testing, laboratory infrastructure and equipment support was provided to over 500 field sites in 74 countries worldwide from October 2008 to September 2009. These activities allowed countries to better meet the milestones of implementation of the 2005 International Health Regulations and complemented many initiatives undertaken by other U.S. government agencies, such as the U.S. Department of Health and Human Services, the U.S. Agency for International Development and the U.S. Department of State. PMID:21388564

  10. Challenges of measles and rubella laboratory diagnostic in the era of elimination.

    PubMed

    Hübschen, J M; Bork, S M; Brown, K E; Mankertz, A; Santibanez, S; Ben Mamou, M; Mulders, M N; Muller, C P

    2017-08-01

    The Member States of the WHO European Region adopted the goal of measles and rubella elimination more than 10 years ago, but so far only 21 of 53 countries have reached this target. Laboratory investigation of suspected cases is essential to support disease elimination efforts. Therefore, WHO maintains a network of accredited laboratories providing high-quality testing. Laboratory investigation heavily relies on specific IgM serology and increasingly on virus detection by reverse transcription (RT)-PCR, but other methods such as IgG avidity testing and genetic characterization of virus strains have gained in importance. In elimination settings, often few samples from suspected cases are available for testing, but testing proficiency must be maintained. The predictive value of an IgM-positive result decreases and other rash-fever disease aetiologies become more important. In addition, cases with a rash after measles/rubella vaccination or with mild disease after waning of vaccine-induced antibodies are seen more often. Thus, it is necessary to perform comprehensive and potentially time-consuming and costly investigations of every suspected case using quality-controlled laboratory methods. At the same time rapid feedback to public health officers is required for timely interventions. The introduction of new laboratory methods for comprehensive case investigations requires training of staff under the supervision of WHO-accredited reference laboratories and the definition of appropriate test algorithms. Clinical, laboratory, and epidemiological data are essential for final case classification and investigation of chains of transmission in the endgame of measles and rubella elimination. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. All rights reserved.

  11. Establishing a China malaria diagnosis reference laboratory network for malaria elimination.

    PubMed

    Yin, Jian-hai; Yan, He; Huang, Fang; Li, Mei; Xiao, Hui-hui; Zhou, Shui-sen; Xia, Zhi-gui

    2015-01-28

    In China, the prevalence of malaria has reduced dramatically due to the elimination programme. The continued success of the programme will depend upon the accurate diagnosis of the disease in the laboratory. The basic requirements for this are a reliable malaria diagnosis laboratory network and quality management system to support case verification and source tracking. The baseline information of provincial malaria laboratories in the China malaria diagnosis reference laboratory network was collected and analysed, and a quality-assurance activity was carried out to assess their accuracies in malaria diagnosis by microscopy using WHO standards and PCR. By the end of 2013, nineteen of 24 provincial laboratories have been included in the network. In the study, a total of 168 staff were registered and there was no bias in their age, gender, education level, and position. Generally Plasmodium species were identified with great accuracy by microscopy and PCR. However, Plasmodium ovale was likely to be misdiagnosed as Plasmodium vivax by microscopy. China has established a laboratory network for primary malaria diagnosis which will cover a larger area. Currently, Plasmodium species can be identified fairly accurately by microscopy and PCR. However, laboratory staff need additional trainings on accurate identification of P. ovale microscopically and good performance of PCR operations.

  12. Complex reference values for endocrine and special chemistry biomarkers across pediatric, adult, and geriatric ages: establishment of robust pediatric and adult reference intervals on the basis of the Canadian Health Measures Survey.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David

    2015-08-01

    Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.

  13. Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance.

    PubMed

    Khairnar, Krishna; Martin, Donald; Lau, Rachel; Ralevski, Filip; Pillai, Dylan R

    2009-12-09

    Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR), and two rapid diagnostic immuno-chromatographic tests (ICT) in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD) analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. QPCR is the most analytically sensitive method (sensitivity 99.41%), followed by CARESTART (sensitivity 88.24%), and BINAXNOW (sensitivity 86.47%) for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R(2) = 0.9746) in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/microl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more costly than reference microscopy. These data suggest that multiplex QPCR although more costly confers a significant diagnostic advantage in terms of LOD compared to reference microscopy and ICTs for all four species. Quality assurance of QPCR is essential to the maintenance of proficiency in the clinical laboratory. ICTs showed good concordance between readers however lacked sensitivity for non-falciparum species due to antigenic differences and low parasitemia. Multiplex QPCR but not ICTs is an essential adjunct to microscopy in the reference laboratory detection of malaria species specifically due to the superior LOD. ICTs are better suited to the non-reference laboratory where lower specimen volumes challenge microscopy proficiency in the non-endemic setting.

  14. Round robin test on quantification of amyloid-β 1-42 in cerebrospinal fluid by mass spectrometry.

    PubMed

    Pannee, Josef; Gobom, Johan; Shaw, Leslie M; Korecka, Magdalena; Chambers, Erin E; Lame, Mary; Jenkins, Rand; Mylott, William; Carrillo, Maria C; Zegers, Ingrid; Zetterberg, Henrik; Blennow, Kaj; Portelius, Erik

    2016-01-01

    Cerebrospinal fluid (CSF) amyloid-β 1-42 (Aβ42) is an important biomarker for Alzheimer's disease, both in diagnostics and to monitor disease-modifying therapies. However, there is a great need for standardization of methods used for quantification. To overcome problems associated with immunoassays, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as a critical orthogonal alternative. We compared results for CSF Aβ42 quantification in a round robin study performed in four laboratories using similar sample preparation methods and LC-MS instrumentation. The LC-MS results showed excellent correlation between laboratories (r(2) >0.98), high analytical precision, and good correlation with enzyme-linked immunosorbent assay (r(2) >0.85). The use of a common reference sample further decreased interlaboratory variation. Our results indicate that LC-MS is suitable for absolute quantification of Aβ42 in CSF and highlight the importance of developing a certified reference material. Copyright © 2016 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  15. Coryneform bacteria in infectious diseases: clinical and laboratory aspects.

    PubMed Central

    Coyle, M B; Lipsky, B A

    1990-01-01

    Coryneform isolates from clinical specimens frequently cannot be identified by either reference laboratories or research laboratories. Many of these organisms are skin flora that belong to a large number of taxonomic groups, only 40% of which are in the genus Corynebacterium. This review provides an update on clinical presentations, microbiological features, and pathogenic mechanisms of infections with nondiphtheria Corynebacterium species and other pleomorphic gram-positive rods. The early literature is also reviewed for a few coryneforms, especially those whose roles as pathogens are controversial. Recognition of newly emerging opportunistic coryneforms is dependent on sound identification schemes which cannot be developed until cell wall analyses and nucleic acid studies have defined the taxonomic groups and all of the reference strains within each taxon have been shown by molecular methods to be authentic members. Only then can reliable batteries of biochemical tests be selected for distinguishing each taxon. PMID:2116939

  16. Communicable Disease Research

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The COSMIC program FITLOS is used regularly by the Centers for Disease Control (CDC), for analyzing data from radioimmunoassays, which involve testing human body substances to provide information on how deficits or excesses of those substances affect a body's ability to ward off disease. A liquid scintillation counter's data is analyzed by the FITLOS program. FITLOS data, then aids in establishing reference methods for hospitals and other health laboratories in their radioimmunoassays. CDC's use of this program enabled them to avoid the cost of designing and developing a new program.

  17. The new policy of the Food and Agriculture Organization of the United Nations and its Reference Centres for the Animal Production and Health Division.

    PubMed

    Lubroth, J

    2007-01-01

    The article explains the current procedures to be followed for institutes that are, were or would like to become Reference Centres for the Food and Agriculture Organization (FAO) of the United Nations. Within the realm of animal health many of the Reference Laboratories and Reference Centres of the World Organisation for Animal Health (OIE) are the same as those of the Animal and Health Division of FAO, particularly for diseases that are transboundary in nature, but they also address other aspects concerning health, production, standard setting, agriculture, conservation, water, and biotechnology.

  18. Laboratory Diagnosis and Characterization of Fungal Disease in Patients with Cystic Fibrosis (CF): A Survey of Current UK Practice in a Cohort of Clinical Microbiology Laboratories.

    PubMed

    Boyle, Maeve; Moore, John E; Whitehouse, Joanna L; Bilton, Diana; Downey, Damian G

    2018-03-02

    There is much uncertainty as to how fungal disease is diagnosed and characterized in patients with cystic fibrosis (CF). A 19-question anonymous electronic questionnaire was developed and distributed to ascertain current practice in clinical microbiology laboratories providing a fungal laboratory service to CF centres in the UK. Analyses of responses identified the following: (1) current UK laboratory practice, in general, follows the current guidelines, but the scope and diversity of what is currently being delivered by laboratories far exceeds what is detailed in the guidelines; (2) there is a lack of standardization of fungal tests amongst laboratories, outside of the current guidelines; (3) both the UK CF Trust Laboratory Standards for Processing Microbiological Samples from People with Cystic Fibrosis and the US Cumulative Techniques and Procedures in Clinical Microbiology (Cumitech) Guidelines 43 Cystic Fibrosis Microbiology need to be updated to reflect both new methodological innovations, as well as better knowledge of fungal disease pathophysiology in CF; (4) there is a need for clinical medicine to decide upon a stratification strategy for the provision of new fungal assays that will add value to the physician in the optimal management of CF patients; (5) there is also a need to rationale what assays should be performed at local laboratory level and those which are best served at National Mycology Reference Laboratory level; and (6) further research is required in developing laboratory assays, which will help ascertain the clinical importance of 'old' fungal pathogens, as well as 'emerging' fungal pathogens.

  19. Constraints on transportation of reagents, reference materials and samples, difficulties and possible solutions: a user's perspective.

    PubMed

    Blanchard, P C

    2006-01-01

    The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.

  20. [Tasks and duties of veterinary reference laboratories for food borne zoonoses].

    PubMed

    Ellerbroek, Lüppo; Alter, T; Johne, R; Nöckler, K; Beutin, L; Helmuth, R

    2009-02-01

    Reference laboratories are of central importance for consumer protection. Field expertise and high scientific competence are basic requirements for the nomination of a national reference laboratory. To ensure a common approach in the analysis of zoonotic hazards, standards have been developed by the reference laboratories together with national official laboratories on the basis of Art. 33 of Directive (EG) No. 882/2004. Reference laboratories function as arbitrative boards in the case of ambivalent or debatable results. New methods for detection of zoonotic agents are developed and validated to provide tools for analysis, e. g., in legal cases, if results from different parties are disputed. Besides these tasks, national reference laboratories offer capacity building and advanced training courses and control the performance of ring trials to ensure consistency in the quality of analyses in official laboratories. All reference laboratories work according to the ISO standard 17025 which defines the grounds for strict laboratory quality rules and in cooperation with the respective Community Reference Laboratories (CRL). From the group of veterinary reference laboratories for food-borne zoonoses, the national reference laboratories are responsible for Listeria monocytogenes, for Campylobacter, for the surveillance and control of viral and bacterial contamination of bivalve molluscs, for E. coli, for the performance of analysis and tests on zoonoses (Salmonella), and from the group of parasitological zoonotic agents, the national reference laboratory for Trichinella.

  1. Concordance in diagnostic testing for respiratory pathogens of bighorn sheep

    USGS Publications Warehouse

    Walsh, Daniel P.; Cassirer, E. Frances; Bonds, Michael D.; Brown, Daniel R.; Edwards, William H.; Weiser, Glen C.; Drew, Mark L.; Briggs, Robert E.; Fox, Karen A.; Miller, Michael W.; Shanthalingam, Sudarvili; Srikumaran, Subramaniam; Besser, Thomas E.

    2016-01-01

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack of appropriate standardized commercial kits. Results of diagnostic testing may also be called into question when investigators report different etiologies for disease outbreaks, despite similar clinical and pathologic findings. To evaluate reliability of diagnostic testing for respiratory pathogens of bighorn sheep (Ovis canadensis), we conducted a series of ring tests across 6 laboratories routinely involved in detection of Mycoplasma ovipneumoniae, Pasteurellaceae, lktA (the Pasteurellaceae gene encoding leukotoxin), and 3 reference laboratories. Consistency of results for replicate samples within laboratories was high (median agreement = 1.0). Agreement between laboratories was high for polymerase chain reaction (PCR) detection of M. ovipneumoniae and culture isolation of Mannheimia spp. and Bibersteinia trehalosi(median agreement = 0.89–0.95, Kappa = 0.65–0.74), and lower for PCR detection of Mannheimiaspp. lktA (median agreement = 0.58, Kappa = 0.12). Most errors on defined status samples were false negatives, suggesting test sensitivity was a greater problem than specificity. However, tests for M. haemolytica and lktA yielded some false positive results. Despite differences in testing protocols, median agreement among laboratories and correct classification of controls for most agents was ≥0.80, meeting or exceeding the standard required by federal proficiency testing programs. This information is valuable for interpreting test results, laboratory quality assessments, and advancing diagnosis of respiratory disease in wild sheep. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  2. EDQM biological reference preparation for rabies vaccine (inactivated) for veterinary use.

    PubMed

    Daas, A; Bruckner, L; Milne, C

    2015-01-01

    Rabies is a deadly zoonotic disease. Control of rabies in animals by vaccination is an important strategy to protect humans from infection and control the spread of the disease. Requirements for the quality control of rabies vaccines (inactivated) for veterinary use include an in vivo quantitative potency determination as outlined in the Ph. Eur. monograph 0451. Performance of this assay requires a reference preparation calibrated in International Units (IU). A European Pharmacopeia (Ph. Eur.) Biological Reference Preparation (BRP) for rabies vaccines (inactivated) for veterinary use, calibrated in IU, has been established for this purpose. Due to the dwindling stocks of the current batch (batch 4) of Ph. Eur. BRP for rabies vaccines (inactivated) for veterinary use, a collaborative study was run as part of the EDQM Biological Standardisation Programme to establish BRP batch 5. Ten laboratories, including Official Medicines Control Laboratories and manufacturers, participated. The candidate BRP5 was assayed against the 6(th) International Standard for rabies vaccine using the in vivo vaccination-challenge assay (monograph 0451) to assign a potency value. The candidate was also compared to BRP batch 4 to establish continuity. Taking into account the results from the comparisons a potency of 10 IU/vial was assigned and in March 2015 the Ph. Eur. Commission adopted the material as Ph. Eur. BRP for rabies vaccines (inactivated) for veterinary use batch 5. In addition to the in vivo assay 3 laboratories tested the candidate material using their in-house in vitro assays for information.

  3. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Electronic reporting of all reference laboratory results: An important step toward a truly all-encompassing, integrated health record.

    PubMed

    Kratz, Alexander

    2016-09-01

    Results from reference laboratories are often not easily available in electronic health records. This article describes a multi-pronged, long-term approach that includes bringing send-out tests in-house, upgrading the laboratory information system, interfacing more send-out tests and more reference laboratories, utilizing the "miscellaneous assay" option offered by some reference laboratories, and scanning all remaining paper reports from reference laboratories for display in the electronic health record. This allowed all laboratory results obtained in association with a patient visit, whether performed in-house or at a reference laboratory, to be available in the integrated electronic health record. This was achieved without manual data entry of reference laboratory results, thereby avoiding the risk of transcription errors. A fully integrated electronic health record that contains all laboratory results can be achieved by maximizing the number of interfaced reference laboratory assays and making all non-interfaced results available as scanned documents. © The Author(s) 2015.

  5. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories.

    PubMed

    Koenen, F; Uttenthal, A; Meindl-Böhmer, A

    2007-12-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning contingency plans. These plans should ensure that in the event of an outbreak access to facilities, equipment, resources, trained personnel, and all other facilities needed for the rapid and efficient eradication of the outbreak is guaranteed, and that the procedures to follow are well rehearsed. It is essential that these plans are established during 'peace-time' and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance of a well-documented laboratory contingency plan. The major pitfalls encountered were shortage of space, difficulties in guaranteeing biosecurity and sufficient supplies of sterile equipment and consumables. The need for a standardised laboratory information management system, that is used by all those involved in order to reduce the administrative load, is also discussed.

  6. Trends in the Epidemiology of Campylobacteriosis in Israel (1999-2012).

    PubMed

    Bassal, Ravit; Lerner, Larisa; Valinsky, Lea; Agmon, Vered; Peled, Nehama; Block, Colin; Keller, Nati; Keness, Yoram; Taran, Diana; Shainberg, Bracha; Ken-Dror, Shifra; Treygerman, Orit; Rouach, Tsvi; Lowenthal, Shulamit; Shohat, Tamar; Cohen, Daniel

    2016-08-01

    The objective of this study was to examine the recent trends in the epidemiology of campylobacteriosis in Israel. A Sentinel Laboratory-Based Surveillance Network for Bacterial Enteric Diseases was established in Israel by the Israel Center for Disease Control (ICDC). This network generated data on subjects from whom Campylobacter spp. was isolated in community and hospital laboratories. Further characterization of the isolates was done at the Campylobacter National Reference Laboratory. Data from these two sources were integrated and analyzed at the ICDC. Between 1999 and 2012, 40,978 Campylobacter stool isolates were reported to the ICDC by the sentinel laboratories. The incidence rate of campylobacteriosis increased from 65.7 per 100,000 in 1999 to 101.7 per 100,000 in 2012. This increase resulted from a significant rise in the incidence of campylobacteriosis in the Jewish population which, since 2009, surpassed the consistent higher incidence of the disease in Israeli Arabs. The peak morbidity in Israel consistently occurred in late spring, with a risk excess in males compared with females, in younger age groups and earlier in the life span among Arabs than among Jews and others. These results suggest that further analytical studies should be carried out to identify risk factors responsible for the increased incidence of campylobacteriosis and better direct prevention and control of the disease in Israel.

  7. Factitious diarrhea induced by stimulant laxatives: accuracy of diagnosis by a clinical reference laboratory using thin layer chromatography.

    PubMed

    Shelton, Joseph H; Santa Ana, Carol A; Thompson, Donald R; Emmett, Michael; Fordtran, John S

    2007-01-01

    Surreptitious ingestion of laxatives can lead to serious factitious diseases that are difficult to diagnose. Most cases involve ingestion of bisacodyl or senna. Thin layer chromatography (TLC) of urine or stool is the only commercially available test for these laxatives. Such testing is considered highly reliable, but its accuracy in clinical practice is unknown. Our aim was to evaluate the reliability of TLC laxative testing by a clinical reference laboratory in the United States. Diarrhea was induced in healthy volunteers by ingestion of bisacodyl, senna, or a control laxative (n = 11 for each laxative group). Samples of urine and diarrheal stool were sent in blinded fashion to the clinical reference laboratory for bisacodyl and senna analysis. TLC testing for bisacodyl-induced diarrhea revealed a sensitivity of 73% and specificity of 91% when urine was tested and sensitivity and specificity of 91% and 96%, respectively, when stool was analyzed. When diarrhea was induced by senna, the TLC assay for senna failed to identify even a single urine or stool specimen as positive (zero% sensitivity). Considering the expected prevalence of surreptitious laxative abuse in patients with chronic idiopathic diarrhea (2.4%-25%, depending on the clinical setting), TLC of urine or stool for bisacodyl by this reference laboratory would often produce misleading results, and testing for senna would have no clinical value. The major problems are false-positive tests for bisacodyl and false-negative tests for senna.

  8. Characterization of 107 Genomic DNA Reference Materials for CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1

    PubMed Central

    Pratt, Victoria M.; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H.; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E.; Wu, Alan H.B.; Yeo, Kiang-Teck J.; Zeller, Markus; Kalman, Lisa

    2010-01-01

    Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research. PMID:20889555

  9. Severe congenital toxoplasmosis in the United States: clinical and serologic findings in untreated infants.

    PubMed

    Olariu, Tudor Rares; Remington, Jack S; McLeod, Rima; Alam, Ambereen; Montoya, Jose G

    2011-12-01

    Congenital toxoplasmosis can cause significant neurologic manifestations and other untoward sequelae. The Palo Alto Medical Foundation Toxoplasma Serology Laboratory database was searched for data on infants 0 to 180 days old, in whom congenital toxoplasmosis had been confirmed and who had been tested for Toxoplasma gondii-specific immunoglobulin G (IgG), IgM, and IgA antibodies, between 1991 and 2005. Their clinical findings were confirmed at the National Collaborative Chicago-based Congenital Toxoplasmosis Study center. We reviewed available clinical data and laboratory profiles of 164 infants with congenital toxoplasmosis whose mothers had not been treated for the parasite during gestation. One or more severe clinical manifestations of congenital toxoplasmosis were reported in 84% of the infants and included eye disease (92.2%), brain calcifications (79.6%), and hydrocephalus (67.7%). In 61.6% of the infants, eye disease, brain calcifications, and hydrocephalus were present concurrently. T. gondii-specific IgM, IgA, and IgE antibodies were demonstrable in 86.6%, 77.4%, and 40.2% of the infants, respectively. Testing for IgM and IgA antibodies increased the sensitivity of making the diagnosis of congenital toxoplasmosis to 93% compared with testing for IgM or IgA individually. IgM and IgA antibodies were still present in 43.9% of infants diagnosed between 1 and 6 months of life. Our study reveals that severe clinical signs of congenital toxoplasmosis including hydrocephalus, eye disease, or intracranial calcifications occurred in 85% infants whose sera were referred to our reference Toxoplasma Serology Laboratory during a period of 15 years. Laboratory tests, including serologic and polymerase chain reaction tests, were critical for diagnosis in the infants. Our results contrast remarkably with those of European investigators who rarely observe severe clinical signs in infants with congenital toxoplasmosis.

  10. Sources and performance criteria of uncertainty of reference measurement procedures.

    PubMed

    Mosca, Andrea; Paleari, Renata

    2018-05-29

    This article wants to focus on the today available Reference Measurement Procedures (RMPs) for the determination of various analytes in Laboratory Medicine and the possible tools to evaluate their performance in the laboratories who are currently using them. A brief review on the RMPs has been performed by investigating the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. In order to evaluate their performances, we have checked the organization of three international ring trials, i.e. those regularly performed by the IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine (RELA), by the Center for Disease Control and Prevention (CDC) cholesterol network and by the IFCC Network for HbA 1c . Several RMPs are available through the JCTLM database, but the best way to collect information about the RMPs and their uncertainties is to look at the reference measurement service providers (RMS). This part of the database and the background on how to listed in the database is very helpful for the assessment of expanded uncertainty (MU) and performance in general of RMPs. Worldwide, 17 RMS are listed in the database, and for most of the measurands more than one RMS is able to run the relative RMPs, with similar expanded uncertainties. As an example, for a-amylase, 4 SP offer their services with MU between 1.6 and 3.3%. In other cases (such as total cholesterol, the U may span over a broader range, i.e. from 0.02 to 3.6%). With regard to the performance evaluation, the approach is often heterogenous, and it is difficult to compare the performance of laboratories running the same RMP for the same measurand if involved in more than one EQAS. The reference measurement services have been created to help laboratory professionals and manufacturers to implement the correct metrological traceability, and the JCTLM database is the only correct way to retrieve all the necessary important information to this end. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. District, state or regional veterinary diagnostic laboratories.

    PubMed

    Gosser, H S; Morehouse, L G

    1998-08-01

    The district, regional or state laboratory is the local laboratory to which veterinarian practitioners usually submit samples, and consequently these laboratories are usually the first to observe a suspected disease problem. In most countries, these laboratories are under the jurisdiction of the State or region in which they are located. In the United States of America (USA), most veterinary diagnostic laboratories are State-associated and operate under the aegis of either the State Department of Agriculture or a university. The national laboratory provides reference assistance to the State laboratories. In the USA, the national Laboratory (the National Veterinary Services Laboratories) acts as a consultant to confirm difficult diagnoses and administer performance tests for State-associated laboratories. District, state or regional laboratories need to share information regarding technological advances in diagnostic procedures. This need was met in the USA by the formation of the American Association of Veterinary Laboratory Diagnosticians (AAVLD) in the late 1950s. Another requirement of district, state or regional diagnostic laboratories is a method to confirm quality assurance, which was fulfilled in the USA by an accreditation programme established through the AAVLD. The Accreditation Committee evaluates laboratories (on request) in terms of organisation, personnel, physical facilities and equipment, records, finance and budget. Those laboratories which meet the standards as established in the 'Essential Requirements for Accreditation' are given accreditation status, which indicates that they have the expertise and facilities to perform tests on food-producing animals for shipment in national or international commerce and on companion, laboratory or zoo animals. While confidentiality of test records is most important, it is becoming necessary to release certain types of animal disease test information if a country is to participate in the exportation of animals and animal products. As district, state and regional laboratories operate under many different administrative entities (i.e., universities, State governments and the Federal government), various checks at different administrative levels provide safeguards and reduce the possibility of faulty disease reporting.

  12. Impact of clinical awareness and diagnostic tests on the underdiagnosis of Clostridium difficile infection.

    PubMed

    Alcalá, L; Reigadas, E; Marín, M; Martín, A; Catalán, P; Bouza, E

    2015-08-01

    A multicenter study of Clostridium difficile infection (CDI) performed during 2008 in Spain revealed that two of every three episodes went undiagnosed or were misdiagnosed owing to nonsensitive diagnostic tests or lack of clinical suspicion and request. Since then, efforts have been made to improve the diagnostic tests used by laboratories and to increase the awareness of this disease among both clinicians and microbiologists. Our objective was to evaluate the impact of these efforts by assessing the current magnitude of underdiagnosis of CDI in Spain using two point-prevalence studies performed on one day each in January and July of 2013. A total of 111 Spanish laboratories selected all unformed stool specimens received for microbiological diagnosis on these days, and toxigenic culture was performed at a central reference laboratory. Toxigenic isolates were characterized both pheno- and genotypically. The reference laboratory detected 103 episodes of CDI in patients aged 2 years or more. Half (50.5 %) of the episodes were not diagnosed in the participating laboratories, owing to insensitive diagnostic tests (15.5 %) or the lack of clinical suspicion and request (35.0 %). The main ribotypes were 014, 078/126, 001/072, and 106. Ribotype 027 caused 2.9 % of all cases. Despite all the interventions undertaken, CDI remains a highly neglected disease because of the lack of sensitive diagnostic tests in some institutions and, especially, the absence of clinical suspicion, mainly in patients with community-associated CDI. Toxigenic C. difficile should be routinely sought in unformed stools sent for microbiological diagnosis, regardless of their origin.

  13. Implications of false positive serology of Toxoplasma gondii in a pre-transplant patient.

    PubMed

    Beal, Stacy; Racsa, Lori; Alatoom, Adnan

    2014-01-01

    A 21-year-old white male with cystic fibrosis. Pre-transplant workup in preparation for bilateral lung transplant. Cystic fibrosis diagnosed at age 3, onset of insulin-dependent diabetes around age 20, and multiple hospitalizations for pulmonary and gastrointestinal complications. FAMILY AND SOCIAL HISTORY: The patient lives with his father and stepmother, has a pet bearded dragon, and has multiple tattoos and piercings. His stepmother has a cat, but he does not clean the litter box. The pre-transplant workup included several tests for infectious diseases, tests of organ function, radiology studies, and markers of malignancy. The only significant finding was a positive Toxoplasma gondii (T. gondii) IgM titer (> or = 1:40) (reference values for IgM: negative; < 1:40, positive; > or = 1:40) and IgG (1:2048) (reference values for IgG: negative; < 1:16, equivocal; > or = 1:16 - < 1:256, positive; > or = 1:256). Testing was done by indirect immunofluorescence assay (IFA) in April 2012 in our hospital laboratory. The patient was treated with sulfadiazine, leucovorin, and pyrimethamine. Three months later (July), he returned for follow-up testing. Real-time polymerase chain reaction (PCR) for T. gondii DNA performed by a reference laboratory was negative. One month later (August), Toxoplasma serology was performed by enzyme-linked immunosorbent assay (ELISA) by a different reference laboratory and showed an elevated IgM of 0.95 IU/mL (reference values: negative; < 0.55 IU/mL, equivocal; > or = 0.55- < 0.65 IU/mL, positive; > or = 0.65 IU/mL) and a normal level of IgG (< 4 IU/mL). At this time, PCR was repeated and was negative. An additional month later (September), the patient's serology studies were performed at a third reference laboratory and showed an elevated IgM of 1.32 IU/mL (reference values: negative; 0.89, equivocal; 0.90 - 1.09, positive; > 1.10) and a normal IgG.

  14. CLSI-derived hematology and biochemistry reference intervals for healthy adults in eastern and southern Africa.

    PubMed

    Karita, Etienne; Ketter, Nzeera; Price, Matt A; Kayitenkore, Kayitesi; Kaleebu, Pontiano; Nanvubya, Annet; Anzala, Omu; Jaoko, Walter; Mutua, Gaudensia; Ruzagira, Eugene; Mulenga, Joseph; Sanders, Eduard J; Mwangome, Mary; Allen, Susan; Bwanika, Agnes; Bahemuka, Ubaldo; Awuondo, Ken; Omosa, Gloria; Farah, Bashir; Amornkul, Pauli; Birungi, Josephine; Yates, Sarah; Stoll-Johnson, Lisa; Gilmour, Jill; Stevens, Gwynn; Shutes, Erin; Manigart, Olivier; Hughes, Peter; Dally, Len; Scott, Janet; Stevens, Wendy; Fast, Pat; Kamali, Anatoli

    2009-01-01

    Clinical laboratory reference intervals have not been established in many African countries, and non-local intervals are commonly used in clinical trials to screen and monitor adverse events (AEs) among African participants. Using laboratory reference intervals derived from other populations excludes potential trial volunteers in Africa and makes AE assessment challenging. The objective of this study was to establish clinical laboratory reference intervals for 25 hematology, immunology and biochemistry values among healthy African adults typical of those who might join a clinical trial. Equal proportions of men and women were invited to participate in a cross sectional study at seven clinical centers (Kigali, Rwanda; Masaka and Entebbe, Uganda; two in Nairobi and one in Kilifi, Kenya; and Lusaka, Zambia). All laboratories used hematology, immunology and biochemistry analyzers validated by an independent clinical laboratory. Clinical and Laboratory Standards Institute guidelines were followed to create study consensus intervals. For comparison, AE grading criteria published by the U.S. National Institute of Allergy and Infectious Diseases Division of AIDS (DAIDS) and other U.S. reference intervals were used. 2,990 potential volunteers were screened, and 2,105 (1,083 men and 1,022 women) were included in the analysis. While some significant gender and regional differences were observed, creating consensus African study intervals from the complete data was possible for 18 of the 25 analytes. Compared to reference intervals from the U.S., we found lower hematocrit and hemoglobin levels, particularly among women, lower white blood cell and neutrophil counts, and lower amylase. Both genders had elevated eosinophil counts, immunoglobulin G, total and direct bilirubin, lactate dehydrogenase and creatine phosphokinase, the latter being more pronounced among women. When graded against U.S. -derived DAIDS AE grading criteria, we observed 774 (35.3%) volunteers with grade one or higher results; 314 (14.9%) had elevated total bilirubin, and 201 (9.6%) had low neutrophil counts. These otherwise healthy volunteers would be excluded or would require special exemption to participate in many clinical trials. To accelerate clinical trials in Africa, and to improve their scientific validity, locally appropriate reference ranges should be used. This study provides ranges that will inform inclusion criteria and evaluation of adverse events for studies in these regions of Africa.

  15. Creatine and guanidinoacetate reference values in a French population.

    PubMed

    Joncquel-Chevalier Curt, Marie; Cheillan, David; Briand, Gilbert; Salomons, Gajja S; Mention-Mulliez, Karine; Dobbelaere, Dries; Cuisset, Jean-Marie; Lion-François, Laurence; Des Portes, Vincent; Chabli, Allel; Valayannopoulos, Vassili; Benoist, Jean-François; Pinard, Jean-Marc; Simard, Gilles; Douay, Olivier; Deiva, Kumaran; Tardieu, Marc; Afenjar, Alexandra; Héron, Delphine; Rivier, François; Chabrol, Brigitte; Prieur, Fabienne; Cartault, François; Pitelet, Gaëlle; Goldenberg, Alice; Bekri, Soumeya; Gerard, Marion; Delorme, Richard; Porchet, Nicole; Vianey-Saban, Christine; Vamecq, Joseph

    2013-11-01

    Creatine and guanidinoacetate are biomarkers of creatine metabolism. Their assays in body fluids may be used for detecting patients with primary creatine deficiency disorders (PCDD), a class of inherited diseases. Their laboratory values in blood and urine may vary with age, requiring that reference normal values are given within the age range. Despite the long known role of creatine for muscle physiology, muscle signs are not necessarily the major complaint expressed by PCDD patients. These disorders drastically affect brain function inducing, in patients, intellectual disability, autistic behavior and other neurological signs (delays in speech and language, epilepsy, ataxia, dystonia and choreoathetosis), being a common feature the drop in brain creatine content. For this reason, screening of PCDD patients has been repeatedly carried out in populations with neurological signs. This report is aimed at providing reference laboratory values and related age ranges found for a large scale population of patients with neurological signs (more than 6 thousand patients) previously serving as a background population for screening French patients with PCDD. These reference laboratory values and age ranges compare rather favorably with literature values for healthy populations. Some differences are also observed, and female participants are discriminated from male participants as regards to urine but not blood values including creatine on creatinine ratio and guanidinoacetate on creatinine ratio values. Such gender differences were previously observed in healthy populations; they might be explained by literature differential effects of testosterone and estrogen in adolescents and adults, and by estrogen effects in prepubertal age on SLC6A8 function. Finally, though they were acquired on a population with neurological signs, the present data might reasonably serve as reference laboratory values in any future medical study exploring abnormalities of creatine metabolism and transport. © 2013 Elsevier Inc. All rights reserved.

  16. Utility of NIST Whole-Genome Reference Materials for the Technical Validation of a Multigene Next-Generation Sequencing Test.

    PubMed

    Shum, Bennett O V; Henner, Ilya; Belluoccio, Daniele; Hinchcliffe, Marcus J

    2017-07-01

    The sensitivity and specificity of next-generation sequencing laboratory developed tests (LDTs) are typically determined by an analyte-specific approach. Analyte-specific validations use disease-specific controls to assess an LDT's ability to detect known pathogenic variants. Alternatively, a methods-based approach can be used for LDT technical validations. Methods-focused validations do not use disease-specific controls but use benchmark reference DNA that contains known variants (benign, variants of unknown significance, and pathogenic) to assess variant calling accuracy of a next-generation sequencing workflow. Recently, four whole-genome reference materials (RMs) from the National Institute of Standards and Technology (NIST) were released to standardize methods-based validations of next-generation sequencing panels across laboratories. We provide a practical method for using NIST RMs to validate multigene panels. We analyzed the utility of RMs in validating a novel newborn screening test that targets 70 genes, called NEO1. Despite the NIST RM variant truth set originating from multiple sequencing platforms, replicates, and library types, we discovered a 5.2% false-negative variant detection rate in the RM truth set genes that were assessed in our validation. We developed a strategy using complementary non-RM controls to demonstrate 99.6% sensitivity of the NEO1 test in detecting variants. Our findings have implications for laboratories or proficiency testing organizations using whole-genome NIST RMs for testing. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  17. Performance of Panfungal- and Specific-PCR-Based Procedures for Etiological Diagnosis of Invasive Fungal Diseases on Tissue Biopsy Specimens with Proven Infection: a 7-Year Retrospective Analysis from a Reference Laboratory

    PubMed Central

    Bernal-Martinez, L.; Castelli, M. V.; Rodriguez-Tudela, J. L.; Cuenca-Estrella, M.

    2014-01-01

    A retrospective analysis of real-time PCR (RT-PCR) results for 151 biopsy samples obtained from 132 patients with proven invasive fungal diseases was performed. PCR-based techniques proved to be fast and sensitive and enabled definitive diagnosis in all cases studied, with detection of a total of 28 fungal species. PMID:24574295

  18. The use of reference change values in clinical laboratories.

    PubMed

    Bugdayci, Guler; Oguzman, Hamdi; Arattan, Havva Yasemin; Sasmaz, Guler

    2015-01-01

    The use of Reference Change Values (RCV) has been advocated as very useful for monitoring individuals. Most of these are performed for monitoring individuals in acute situations and for following up the improvement or deterioration of chronic diseases. In our study, we aimed at evaluating the RCV calculation for 24 clinical chemistry analytes widely used in clinical laboratories and the utilization of this data. Twenty-four serum samples were analyzed with Abbott kits (Abbott Laboratories, Abbott Park, IL, USA), manufactured for use with the Architect c8000 (Abbott Laboratories, Abbott Park, IL, USA) auto-analyzer. We calculated RCV using the following formula: RCV = Z x 2 1/2x (CVA2 + CVw2)1/2. Four reference change values (RCV) were calculated for each analyte using four statistical probabilities (0.95, and 0.99, unidirectional and bidirectional). Moreover, by providing an interval after identifying upper and lower limits with the Reference Change Factor (RCF), serially measured tests were calculated by using two formulas: exp (Z x 2 1/2 x (CV(A)2 + CVw2)½/100) for RCF(UP) and (1/RCF(UP)) for RCF(DOWN). RCVs of these analytes were calculated as 14.63% for glucose, 29.88% for urea, 17.75% for ALP, 53.39% for CK, 46.98% for CK-MB, 21.00% amylase, 8.00% for total protein, 8.70% for albumin, 51.08% for total bilirubin, 86.34% for direct bilirubin, 6.40% for calcium, 15.03% for creatinine, 21.47% for urate, 14.19% for total cholesterol, 46.62% for triglyceride, 20.51% for HDL-cholesterol, 29.59% for AST, 46.31% for ALT, 31.54% for GGT, 20.92% for LDH, 19.75% for inorganic phosphate, 3.05% for sodium, 11.75% for potassium, 4.44% for chloride (RCV, p < 0.05, unidirectionally). We suggest using RCV as well as using population-based reference intervals in clinical laboratories. RCV could be available as a tool for making clinical decision, especially when monitoring individuals.

  19. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.

  20. The management of Gaucher disease in developing countries: a successful experience in Southern Brazil.

    PubMed

    Krug, B C; Schwartz, I V; Lopes de Oliveira, F; Alegra, T; Campos Martins, N L; Todeschini, L A; Picon, P D

    2010-01-01

    Gaucher disease (GD) is a genetic disease caused by glucocerebrosidase deficiency. GD is treated by enzyme replacement therapy (ERT) with imiglucerase, a high-cost drug provided by the Brazilian Ministry of Health (BMH). This study reports the implementation of the BMH guidelines for GD in the southernmost state of the country. We review the clinical and laboratorial data for patients seen at the reference center for GD from Rio Grande do Sul, Brazil (July 2003 to June 2006). Twenty-five patients were included in this study. At baseline, 19/20 were on ERT (mean dosage of imiglucerase = 51.8 U/kg/infusion), 3/17 presented anemia, and 5/16 thrombocytopenia. The amount of imiglucerase prescribed to these patients was adjusted according to the guidelines in July 2003; out of them, 18 were receiving ERT in the reference center at month 36 (mean dosage of imiglucerase = 27.5 U/kg/infusion), 2/18 presented anemia, and 4/18 presented thrombocytopenia. The analysis of the liver, spleen, and bone data presented some limitations, but the available information suggests that patients did not deteriorate. GD patients who initiated ERT after July 2003 (n = 5) received lower dosage of imiglucerase since the beginning of the treatment; most of them demonstrated clinical and laboratorial response. From baseline to month 36, the consumption of imiglucerase by the reference center showed a significant reduction, which represented savings of USD 3 million to the public health system. The model of care of GD patients suggested by the BMH guidelines appears to be cost-effective and could be an example for management of rare diseases in underdeveloped countries. Copyright © 2009 S. Karger AG, Basel.

  1. Brucella abortus Strain 2308 Wisconsin Genome: Importance of the Definition of Reference Strains

    PubMed Central

    Suárez-Esquivel, Marcela; Ruiz-Villalobos, Nazareth; Castillo-Zeledón, Amanda; Jiménez-Rojas, César; Roop II, R. Martin; Comerci, Diego J.; Barquero-Calvo, Elías; Chacón-Díaz, Carlos; Caswell, Clayton C.; Baker, Kate S.; Chaves-Olarte, Esteban; Thomson, Nicholas R.; Moreno, Edgardo; Letesson, Jean J.; De Bolle, Xavier; Guzmán-Verri, Caterina

    2016-01-01

    Brucellosis is a bacterial infectious disease affecting a wide range of mammals and a neglected zoonosis caused by species of the genetically homogenous genus Brucella. As in most studies on bacterial diseases, research in brucellosis is carried out by using reference strains as canonical models to understand the mechanisms underlying host pathogen interactions. We performed whole genome sequencing analysis of the reference strain B. abortus 2308 routinely used in our laboratory, including manual curated annotation accessible as an editable version through a link at https://en.wikipedia.org/wiki/Brucella#Genomics. Comparison of this genome with two publically available 2308 genomes showed significant differences, particularly indels related to insertional elements, suggesting variability related to the transposition of these elements within the same strain. Considering the outcome of high resolution genomic techniques in the bacteriology field, the conventional concept of strain definition needs to be revised. PMID:27746773

  2. Systemic Epstein-Barr Virus-positive T-Cell Lymphoproliferative Disease of Childhood With Good Response to Steroid Therapy.

    PubMed

    Kim, Do-Hoon; Kim, Myungshin; Kim, Yonggoo; Han, Kyungja; Han, Eunhee; Lee, Jae Wook; Chung, Nack-Gyun; Cho, Bin

    2017-11-01

    Systemic Epstein-Barr virus (EBV)-positive T-cell lymphoproliferative disease of childhood is a rare disease and has a very fulminant clinical course with high mortality. A 21-month-old female patient was referred to our hospital with a 1 week history of fever and was subsequently diagnosed with systemic Epstein-Barr virus-positive T-cell lymphoproliferative disease of childhood. After starting treatment with dexamethasone, she showed early defervescence and improvement of laboratory parameters, and has remained disease-free after stopping steroid treatment, although longer follow-up is necessary. Our report underscores the possibility that this disease entity may be heterogenous in terms of prognosis.

  3. A multicenter study on PIVKA reference interval of healthy population and establishment of PIVKA cutoff value for hepatocellular carcinoma diagnosis in China.

    PubMed

    Qin, X; Tang, G; Gao, R; Guo, Z; Liu, Z; Yu, S; Chen, M; Tao, Z; Li, S; Liu, M; Wang, L; Hou, L; Xia, L; Cheng, X; Han, J; Qiu, L

    2017-08-01

    The aim of this study was to investigate the reference interval of protein-induced vitamin K absence or antagonist-II (PIVKA-II) in China population and to evaluate its medical decision level for hepatocellular carcinoma (HCC) diagnosis. To determine the reference range for Chinese individuals, a total of 855 healthy subjects in five typical regions of China were enrolled in this study to obtain a 95% reference interval. In a case-control study which recruited the subjects diagnosed with HCC, metastatic liver cancer, bile duct cancer, hepatitis, cirrhosis, other benign liver diseases and the subjects administrated anticoagulant, receiver operating characteristic analysis was used to determine PIVKA-II cutoff value for a medical decision. The concentration of PIVKA-II had no relationship with age or gender and that region was a significant factor associated with the level of PIVKA-II. The 95% reference interval determined in this study for PIVKA-II in Chinese healthy individuals was 28 mAU/mL, and the cutoff value which to distinguish patients with HCC from disease control groups is 36.5 mAU/mL. In clinical applications, it is recommended that each laboratory chooses their own reference interval based on the regional population study or cutoff value for disease diagnosis. © 2017 John Wiley & Sons Ltd.

  4. Laboratory confirmation of rubella infection in suspected measles cases.

    PubMed

    Vaidya, Sunil R; Raut, Chandrashekhar G; Jadhav, Santoshkumar M

    2016-10-01

    As a part of measles outbreak based surveillance undertaken by the World Health Organization India, suspected measles cases were referred for the laboratory diagnosis at National Institute of Virology (NIV) Pune and NIV Unit Bengaluru. Altogether, 4,592 serum samples were referred during 2010-2015 from the States of Karnataka (n = 1,173), Kerala (n = 559), and Maharashtra (n = 2,860). Initially, serum samples were tested in measles IgM antibody EIA and samples with measles negative and equivocal results (n = 1,954) were subjected to rubella IgM antibody detection. Overall, 62.9% (2,889/4,592) samples were laboratory confirmed measles, 27.7% (542/1,954) were laboratory confirmed rubella and remaining 25.2% (1,161/4,592) were negative for measles and rubella. The measles vaccination status was available for 1,206 cases. Among the vaccinated individuals, 50.7% (612/1,206) were laboratory confirmed measles. The contribution of laboratory confirmed measles was 493 (40.8%) from Maharashtra, 90 (7.5%) from Karnataka, and 29 (2.4%) from Kerala. Since, 1/3rd of suspected measles cases were laboratory confirmed rubella, an urgent attention needed to build rubella surveillance in India. Additional efforts are required to rule out other exanthematous disease including Dengue and Chikungunya in measles and rubella negatives. J. Med. Virol. 88:1685-1689, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  6. Validation of Metagenomic Next-Generation Sequencing Tests for Universal Pathogen Detection.

    PubMed

    Schlaberg, Robert; Chiu, Charles Y; Miller, Steve; Procop, Gary W; Weinstock, George

    2017-06-01

    - Metagenomic sequencing can be used for detection of any pathogens using unbiased, shotgun next-generation sequencing (NGS), without the need for sequence-specific amplification. Proof-of-concept has been demonstrated in infectious disease outbreaks of unknown causes and in patients with suspected infections but negative results for conventional tests. Metagenomic NGS tests hold great promise to improve infectious disease diagnostics, especially in immunocompromised and critically ill patients. - To discuss challenges and provide example solutions for validating metagenomic pathogen detection tests in clinical laboratories. A summary of current regulatory requirements, largely based on prior guidance for NGS testing in constitutional genetics and oncology, is provided. - Examples from 2 separate validation studies are provided for steps from assay design, and validation of wet bench and bioinformatics protocols, to quality control and assurance. - Although laboratory and data analysis workflows are still complex, metagenomic NGS tests for infectious diseases are increasingly being validated in clinical laboratories. Many parallels exist to NGS tests in other fields. Nevertheless, specimen preparation, rapidly evolving data analysis algorithms, and incomplete reference sequence databases are idiosyncratic to the field of microbiology and often overlooked.

  7. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    PubMed

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Establishment of the first international repository for transfusion-relevant bacteria reference strains: ISBT working party transfusion-transmitted infectious diseases (WP-TTID), subgroup on bacteria.

    PubMed

    Störmer, M; Arroyo, A; Brachert, J; Carrero, H; Devine, D; Epstein, J S; Gabriel, C; Gelber, C; Goodrich, R; Hanschmann, K-M; Heath, D G; Jacobs, M R; Keil, S; de Korte, D; Lambrecht, B; Lee, C-K; Marcelis, J; Marschner, S; McDonald, C; McGuane, S; McKee, M; Müller, T H; Muthivhi, T; Pettersson, A; Radziwon, P; Ramirez-Arcos, S; Reesink, H W; Rojo, J; Rood, I; Schmidt, M; Schneider, C K; Seifried, E; Sicker, U; Wendel, S; Wood, E M; Yomtovian, R A; Montag, T

    2012-01-01

    Bacterial contamination of platelet concentrates (PCs) still remains a significant problem in transfusion with potential important clinical consequences, including death. The International Society of Blood Transfusion Working Party on Transfusion-Transmitted Infectious Diseases, Subgroup on Bacteria, organised an international study on Transfusion-Relevant Bacteria References to be used as a tool for development, validation and comparison of both bacterial screening and pathogen reduction methods. Four Bacteria References (Staphylococcus epidermidis PEI-B-06, Streptococcus pyogenes PEI-B-20, Klebsiella pneumoniae PEI-B-08 and Escherichia coli PEI-B-19) were selected regarding their ability to proliferate to high counts in PCs and distributed anonymised to 14 laboratories in 10 countries for identification, enumeration and bacterial proliferation in PCs after low spiking (0·3 and 0·03 CFU/ml), to simulate contamination occurring during blood donation. Bacteria References were correctly identified in 98% of all 52 identifications. S. pyogenes and E. coli grew in PCs in 11 out of 12 laboratories, and K. pneumoniae and S. epidermidis replicated in all participating laboratories. The results of bacterial counts were very consistent between laboratories: the 95% confidence intervals were for S. epidermidis: 1·19-1·32 × 10(7) CFU/ml, S. pyogenes: 0·58-0·69 × 10(7) CFU/ml, K. pneumoniae: 18·71-20·26 × 10(7) CFU/ml and E. coli: 1·78-2·10 × 10(7) CFU/ml. The study was undertaken as a proof of principle with the aim to demonstrate (i) the quality, stability and suitability of the bacterial strains for low-titre spiking of blood components, (ii) the property of donor-independent proliferation in PCs, and (iii) their suitability for worldwide shipping of deep frozen, blinded pathogenic bacteria. These aims were successfully fulfilled. The WHO Expert Committee Biological Standardisation has approved the adoption of these four bacteria strains as the first Repository for Transfusion-Relevant Bacteria Reference Strains and, additionally, endorsed as a project the addition of six further bacteria strain preparations suitable for control of platelet contamination as the next step of enlargement of the repository. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.

  9. The use of digital PCR to improve the application of quantitative molecular diagnostic methods for tuberculosis.

    PubMed

    Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F

    2016-08-03

    Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.

  10. Billing code algorithms to identify cases of peripheral artery disease from administrative data

    PubMed Central

    Fan, Jin; Arruda-Olson, Adelaide M; Leibson, Cynthia L; Smith, Carin; Liu, Guanghui; Bailey, Kent R; Kullo, Iftikhar J

    2013-01-01

    Objective To construct and validate billing code algorithms for identifying patients with peripheral arterial disease (PAD). Methods We extracted all encounters and line item details including PAD-related billing codes at Mayo Clinic Rochester, Minnesota, between July 1, 1997 and June 30, 2008; 22 712 patients evaluated in the vascular laboratory were divided into training and validation sets. Multiple logistic regression analysis was used to create an integer code score from the training dataset, and this was tested in the validation set. We applied a model-based code algorithm to patients evaluated in the vascular laboratory and compared this with a simpler algorithm (presence of at least one of the ICD-9 PAD codes 440.20–440.29). We also applied both algorithms to a community-based sample (n=4420), followed by a manual review. Results The logistic regression model performed well in both training and validation datasets (c statistic=0.91). In patients evaluated in the vascular laboratory, the model-based code algorithm provided better negative predictive value. The simpler algorithm was reasonably accurate for identification of PAD status, with lesser sensitivity and greater specificity. In the community-based sample, the sensitivity (38.7% vs 68.0%) of the simpler algorithm was much lower, whereas the specificity (92.0% vs 87.6%) was higher than the model-based algorithm. Conclusions A model-based billing code algorithm had reasonable accuracy in identifying PAD cases from the community, and in patients referred to the non-invasive vascular laboratory. The simpler algorithm had reasonable accuracy for identification of PAD in patients referred to the vascular laboratory but was significantly less sensitive in a community-based sample. PMID:24166724

  11. Reference values for 34 frequently used laboratory tests in 80-year-old men and women.

    PubMed

    Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders

    2016-10-01

    Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Evaluation of the World Health Organization global measles and rubella quality assurance program, 2001-2008.

    PubMed

    Stambos, Vicki; Leydon, Jennie; Riddell, Michaela; Clothier, Hazel; Catton, Mike; Featherstone, David; Kelly, Heath

    2011-07-01

    During 2001-2008, the Victorian Infectious Diseases Reference Laboratory (VIDRL) prepared and provided a measles and rubella proficiency test panel for distribution to the World Health Organization (WHO) measles and rubella network laboratories as part of their annual laboratory accreditation assessment. Panel test results were forwarded to VIDRL, and results from 8 consecutive years were analyzed. We assessed the type of assays used and results achieved on the basis of the positive and negative interpretation of submitted results, by year and WHO region, for measles and rubella. Over time, there has been a noticeable increase in laboratory and WHO regional participation. For all panels, the proportion of laboratories in all WHO regions using the WHO-validated Dade Behring assay for measles and rubella-specific IgM antibodies ranged from 35% to 100% and 59% to 100%, respectively. For all regions and years, the proportion of laboratories obtaining a pass score ranged from 87% to 100% for measles and 93% to 100% for rubella. During 2001-2008, a large proportion of laboratories worldwide achieved and maintained a pass score for both measles and rubella. Measles and rubella proficiency testing is regarded as a major achievement for the WHO measles and rubella laboratory program. © The Author 2011. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved.

  13. Prevalence of. cap alpha. /sub 1/-antitrypsin heterozygotes (Pi MZ) in patients with obstructive pulmonary disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shigeoka, J.W.; Hall, W.J.; Hyde, R.W.

    1976-01-01

    An increased incidence of intermediate deficiency of serum ..cap alpha../sub 1/-antitrypsin resulting from Pi phenotype MZ has been reported in patients with chronic obstructive pulmonary disease (COPD) by some laboratories but not confirmed by others. Prevalence of Pi MZ was determined in patients with COPD among 502 subjects referred to a pulmonary function testing laboratory in a region with low concentrations of air pollutants. Control prevalences were obtained from 930 randomly selected subjects in the same community as well as from patients without COPD referred to the laboratory. Depending on criteria used to define COPD, 155 to 306 subjects hadmore » COPD. Pi MZ prevalence in subjects with COPD varied from 1.5 to 4 times the prevalence in the community control group and in the patients without COPD. This difference approached significance or was significant. Because Pi MZ was present in only 3.5 to 4.5% of patients with COPD, Pi MZ is not a major factor in the etiology of COPD in this community. The higher incidence of Pi MZ in patients with COPD reported by other investigators may be explained by small sample size, bias in selection of study or control population groups, or the development of COPD from interaction between Pi MZ and air pollutants or other factors not present in this community.« less

  14. Active-learning laboratory session to teach the four M's of diabetes care.

    PubMed

    Darbishire, Patricia L; Plake, Kimberly S; Nash, Christiane L; Shepler, Brian M

    2009-04-07

    To implement an active-learning methodology for teaching diabetes care to pharmacy students and evaluate its effectiveness. Laboratory instruction was divided into 4 primary areas of diabetes care, referred to by the mnemonic, the 4 M's: meal planning, motion, medication, and monitoring. Students participated in skill-based learning laboratory stations and in simulated patient experiences. A pretest, retrospective pretest, and posttest were administered to measure improvements in students' knowledge about diabetes and confidence in providing care to diabetes patients. Students knowledge of and confidence in each area assessed improved. Students enjoyed the laboratory session and felt it contributed to their learning. An active-learning approach to teaching diabetes care allowed students to experience aspects of the disease from the patient's perspective. This approach will be incorporated in other content areas.

  15. Evaluation of molecular typing of foodborne pathogens in European reference laboratories from 2012 to 2013

    PubMed Central

    Schjørring, Susanne; Niskanen, Taina; Torpdahl, Mia; Björkman, Jonas T; Nielsen, Eva Møller

    2016-01-01

    In 2012, the European Centre for Disease Prevention and Control (ECDC) initiated external quality assessment (EQA) schemes for molecular typing including the National Public Health Reference Laboratories in Europe. The overall aim for these EQA schemes was to enhance the European surveillance of food-borne pathogens by evaluating and improving the quality and comparability of molecular typing. The EQAs were organised by Statens Serum Institut (SSI) and included Salmonella enterica subsp. enterica, verocytotoxin-producing Escherichia coli (VTEC) and Listeria monocytogenes. Inter-laboratory comparable pulsed-field gel electrophoresis (PFGE) images were obtained from 10 of 17 of the participating laboratories for Listeria, 15 of 25 for Salmonella, but only nine of 20 for VTEC. Most problems were related to PFGE running conditions and/or incorrect use of image acquisition. Analysis of the gels was done in good accordance with the provided guidelines. Furthermore, we assessed the multilocus variable-number tandem repeat analysis (MLVA) scheme for S. Typhimurium. Of 15 laboratories, nine submitted correct results for all analysed strains, and four had difficulties with one strain only. In conclusion, both PFGE and MLVA are prone to variation in quality, and there is therefore a continuous need for standardisation and validation of laboratory performance for molecular typing methods of food-borne pathogens in the human public health sector. PMID:28006653

  16. Indirect methods for reference interval determination - review and recommendations.

    PubMed

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  17. A sensitive LC-MS/MS method for the quantification of urinary 8-iso-prostaglandin F2α (8-iso-PGF2α) including pediatric reference interval.

    PubMed

    Xiao, Yi; Fu, Xiaowei; Pattengale, Paul; Dien Bard, Jennifer; Xu, Yan-Kang; O'Gorman, Maurice R

    2016-09-01

    Oxidative stress has been implicated in numerous diseases, including arthritis, atherosclerosis, Alzheimer's disease, cancer, diabetes, hypertension, and inflammation. 8-iso-prostaglandin F2α, a member of the F2 isoprostane family, has been well-accepted as a valuable biomarker for the assessment of oxidative stress. We report the development and validation of an ultra-sensitive LC-MS/MS assay for urinary 8-iso-PGF2α measurements in pediatric population. The assay was linear from 0.024 to 20nmol/l (R(2)=0.99). Recoveries were above 85% and matrix effects were below 5%. The variability was determined at nmol/l concentration: the intra-day variability (%CV) ranged from 3.9% to 4.5% (n=20); and the inter-day variability ranged from 4.3% to 5.7% (n=20). The accuracy of our laboratory developed test was evaluated with a clinical reference laboratory (n=39), and a correlation coefficient of 0.9257 was observed. Reference interval were established to be <0.5ng/mg creatinine in a group of pediatric population (2months-18years, n=123). The precision of the assay will allow for accurate assessment of oxidative stress, and is acceptable for patient testing, particularly in pediatric population. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Laboratory preparedness for detection and monitoring of Shiga toxin 2-producing Escherichia coli O104:H4 in Europe and response to the 2011 outbreak.

    PubMed

    Rosin, P; Niskanen, T; Palm, D; Struelens, M; Takkinen, J

    2013-06-20

    A hybrid strain of enteroaggregative and Shiga toxin 2-producing Escherichia coli (EAEC-STEC) serotype O104:H4 strain caused a large outbreak of haemolytic uraemic syndrome and bloody diarrhoea in 2011 in Europe. Two surveys were performed in the European Union (EU) and European Economic Area (EEA) countries to assess their laboratory capabilities to detect and characterise this previously uncommon STEC strain. Prior to the outbreak, 11 of the 32 countries in this survey had capacity at national reference laboratory (NRL) level for epidemic case confirmation according to the EU definition. During the outbreak, at primary diagnostic level, nine countries reported that clinical microbiology laboratories routinely used Shiga toxin detection assays suitable for diagnosis of infections with EAEC-STEC O104:H4, while 14 countries had NRL capacity to confirm epidemic cases. Six months after the outbreak, 22 countries reported NRL capacity to confirm such cases following initiatives taken by NRLs and the European Centre for Disease Prevention and Control (ECDC) Food- and Waterborne Disease and Zoonoses laboratory network. These data highlight the challenge of detection and confirmation of epidemic infections caused by atypical STEC strains and the benefits of coordinated EU laboratory networks to strengthen capabilities in response to a major outbreak.

  19. [The history of organization of the research laboratories based at the Department of Otorhinolaryngology of the Faculty of General Medicine].

    PubMed

    Lapchenko, A S; Kucherov, A G; Ivanets, I V; Aslamazova, V I; Order, R Ya; Yushkina, M A

    This article was designed to describe the history of the establishment and development of the research divisions based at the Department of Otorhinolaryngology of the Faculty of General Medicine, N.I. Pirogov Russian National Research Medical University, including laser, vestibulogical, and audiological laboratories. The authors present an overview of the main research activities and achievements of the Department with special reference to the management of Meniere's disease, cochlear-vestibular disorders associated with sensorineural hearing loss, injuries to the organs of hearing, and diseases of the central nervous system. Also discussed are the peculiarities of the laser-assisted medical care and the possibilities for the application of therapeutic and surgical lasers for the purposes of the practical otorhinolaryngological work.

  20. Laboratory preparedness in EU/EEA countries for detection of novel avian influenza A(H7N9) virus, May 2013

    PubMed Central

    Broberg, E; Pereyaslov, D; Struelens, M; Palm, D; Meijer, A; Ellis, J; Zambon, M; McCauley, J; Daniels, R

    2015-01-01

    Following human infections with novel avian influenza A(H7N9) viruses in China, the European Centre for Disease Prevention and Control, the World Health Organization (WHO) Regional Office for Europe and the European Reference Laboratory Network for Human Influenza (ERLI-Net) rapidly posted relevant information, including real-time RT-PCR protocols. An influenza RNA sequence-based computational assessment of detection capabilities for this virus was conducted in 32 national influenza reference laboratories in 29 countries, mostly WHO National Influenza Centres participating in the WHO Global Influenza Surveillance and Response System (GISRS). Twenty-seven countries considered their generic influenza A virus detection assay to be appropriate for the novel A(H7N9) viruses. Twenty-two countries reported having containment facilities suitable for its isolation and propagation. Laboratories in 27 countries had applied specific H7 real-time RT-PCR assays and 20 countries had N9 assays in place. Positive control virus RNA was provided by the WHO Collaborating Centre in London to 34 laboratories in 22 countries to allow evaluation of their assays. Performance of the generic influenza A virus detection and H7 and N9 subtyping assays was good in 24 laboratories in 19 countries. The survey showed that ERLI-Net laboratories had rapidly developed and verified good capability to detect the novel A(H7N9) influenza viruses. PMID:24507469

  1. Evaluation of Commercially Available Diagnostic Tests for the Detection of Dengue Virus NS1 Antigen and Anti-Dengue Virus IgM Antibody

    PubMed Central

    Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.

    2014-01-01

    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157

  2. Prevention of infectious tick-borne diseases in humans: Comparative studies of the repellency of different dodecanoic acid-formulations against Ixodes ricinus ticks (Acari: Ixodidae)

    PubMed Central

    Schwantes, Ulrich; Dautel, Hans; Jung, Gerd

    2008-01-01

    Background Ticks of the species Ixodes ricinus are the main vectors of Lyme Borreliosis and Tick-borne Encephalitis – two rapidly emerging diseases in Europe. Repellents provide a practical means of protection against tick bites and can therefore minimize the transmission of tick-borne diseases. We developed and tested seven different dodecanoic acid (DDA)-formulations for their efficacy in repelling host-seeking nymphs of I. ricinus by laboratory screening. The ultimately selected formulation was then used for comparative investigations of commercially available tick repellents in humans. Methods Laboratory screening tests were performed using the Moving-object (MO) bioassay. All test formulations contained 10% of the naturally occurring active substance DDA and differed only in terms of the quantitative and qualitative composition of inactive ingredients and fragrances. The test procedure used in the human bioassays is a modification of an assay described by the U.S. Environmental Protection Agency and recommended for regulatory affairs. Repellency was computed using the equation: R = 100 - NR/N × 100, where NR is the number of non-repelled ticks, and N is the respective number of control ticks. All investigations were conducted in a controlled laboratory environment offering standardized test conditions. Results All test formulations strongly repelled nymphs of I. ricinus (100-81% protection) as shown by the MO-bioassay. The majority of ticks dropped off the treated surface of the heated rotating drum that served as the attractant (1 mg/cm2 repellent applied). The 10% DDA-based formulation, that produced the best results in laboratory screening, was as effective as the coconut oil-based reference product. The mean protection time of both preparations was generally similar and averaged 8 hours. Repellency investigations in humans showed that the most effective 10% DDA-based formulation (~1.67 mg/cm2 applied) strongly avoided the attachment of I. ricinus nymphs and adults for at least 6 hours. The test repellent always provided protection (83-63%) against I. ricinus nymphs equivalent to the natural coconut oil based reference product and a better protection (88-75%) against adult ticks than the synthetic Icaridin-containing reference repellent. Conclusion We found that the 10% DDA-based formulation (ContraZeck®) is an easily applied and very effective natural repellent against I. ricinus ticks. By reducing the human-vector contact the product minimises the risk of transmission of tick-borne diseases in humans. PMID:18397516

  3. Estimated Glomerular Filtration Rate; Laboratory Implementation and Current Global Status.

    PubMed

    Miller, W Greg; Jones, Graham R D

    2018-01-01

    In 2002, the Kidney Disease Outcomes Quality Initiative guidelines for identifying and treating CKD recommended that clinical laboratories report estimated glomerular filtration rate (eGFR) with every creatinine result to assist clinical practitioners to identify people with early-stage CKD. At that time, the original Modification of Diet in Renal Disease (MDRD) Study equation based on serum creatinine measurements was recommended for calculating eGFR. Because the MDRD Study equation was developed using a nonstandardized creatinine method, a Laboratory Working Group of the National Kidney Disease Education program was formed and implemented standardized calibration traceability for all creatinine methods from global manufacturers by approximately 2010. A modified MDRD Study equation for use with standardized creatinine was developed. The Chronic Kidney Disease Epidemiology Collaboration developed a new equation in 2009 that was more accurate than the MDRD Study equation at values above 60 mL/min/1.73 m 2 . As of 2017, reporting eGFR with creatinine is almost universal in many countries. A reference system for cystatin C became available in 2010, and manufacturers are in the process to standardize cystatin C assays. Equations for eGFR based on standardized cystatin C alone and with creatinine are now available from the Chronic Kidney Disease Epidemiology Collaboration and other groups. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  4. Development of a gas chromatography-mass spectrometry technique to diagnose white snakeroot (Ageratina altissima) poisoning in a cow

    USDA-ARS?s Scientific Manuscript database

    An 8-year-old, crossbred beef cow was referred to the Indiana Animal Disease Diagnostic Laboratory at Purdue University for a complete necropsy in October 2009. The cow was the sixth to die in a 7-day period. Affected cows were reportedly stumbling and became weak, excitable, and recumbent. Histolog...

  5. The effect of positive family history of autoimmunity in juvenile idiopathic arthritis characteristics; a case control study.

    PubMed

    Khani, Mehdi; Ziaee, Vahid; Moradinejad, Mohamad-Hassan; Parvaneh, Nima

    2013-10-01

    To compare Juvenile Idiopathic Arthritis (JIA) patients with and without family history of autoimmune disease with respect to clinical features and laboratory data. Sixteen JIA patients with family history of autoimmune disease were identified during study, 32 patients were chosen for comparative group from referred patients to the rheumatology clinic according to the date of referral. Two groups were compared with respect to age of onset, sex, subtype, disease activity, duration of active disease and laboratory variables. The age of onset was significantly lower in JIA patients with family history of autoimmunity (4.7 years vs. 7.0 years; P=0.02), polyarthicular subtype was more frequent in patients with positive family history (50% vs.25%; P=0.04) most of JIA patients with positive family history were in the active phase at the time of study (64% vs 25%; P=0.02) and had a longer duration of active disease (21.0 months vs 12.3 months; P=0.04). Patients with positive family history had more positive ANA (43.5%% vs 12.5%; P=0.01) and also more positive ADA (75% vs 20.8%; P=0.002). Two groups were similar according to sex, and other laboratory variables. JIA patients with family history of autoimmune disease seem to have a more severe disease than patients without such family history, they are younger at the onset, and have mostly poyarthicular subtype. They also have more ANA and ADA positivity. These findings are different from familial JIA case-control studies according to active disease duration, subtype, and ANA positivity.

  6. Livestock-associated meticillin-resistant Staphylococcus aureus (MRSA) among human MRSA isolates, European Union/European Economic Area countries, 2013

    PubMed Central

    Kinross, Pete; Petersen, Andreas; Skov, Robert; Van Hauwermeiren, Evelyn; Pantosti, Annalisa; Laurent, Frédéric; Voss, Andreas; Kluytmans, Jan; Struelens, Marc J; Heuer, Ole; Monnet, Dominique L

    2017-01-01

    Currently, surveillance of livestock-associated meticillin-resistant Staphylococcus aureus (LA-MRSA) in humans in Europe is not systematic but mainly event-based. In September 2014, the European Centre for Disease Prevention and Control (ECDC) initiated a questionnaire to collect data on the number of LA-MRSA from human samples (one isolate per patient) from national/regional reference laboratories in European Union/European Economic Area (EU/EEA) countries in 2013. Identification of LA-MRSA as clonal complex (CC) 398 by multilocus sequence typing (MLST) was preferred, although surrogate methods such as spa-typing were also accepted. The questionnaire was returned by 28 laboratories in 27 EU/EEA countries. Overall, LA-MRSA represented 3.9% of 13,756 typed MRSA human isolates, but it represented ≥ 10% in five countries (Belgium, Denmark, Spain, the Netherlands and Slovenia). Seven of the reference laboratories did not type MRSA isolates in 2013. To monitor the dispersion of LA-MRSA and facilitate targeted control measures, we advocate periodic systematic surveys or integrated multi-sectorial surveillance. PMID:29113628

  7. Livestock-associated meticillin-resistant Staphylococcus aureus (MRSA) among human MRSA isolates, European Union/European Economic Area countries, 2013.

    PubMed

    Kinross, Pete; Petersen, Andreas; Skov, Robert; Van Hauwermeiren, Evelyn; Pantosti, Annalisa; Laurent, Frédéric; Voss, Andreas; Kluytmans, Jan; Struelens, Marc J; Heuer, Ole; Monnet, Dominique L

    2017-11-01

    Currently, surveillance of livestock-associated meticillin-resistant Staphylococcus aureus (LA-MRSA) in humans in Europe is not systematic but mainly event-based. In September 2014, the European Centre for Disease Prevention and Control (ECDC) initiated a questionnaire to collect data on the number of LA-MRSA from human samples (one isolate per patient) from national/regional reference laboratories in European Union/European Economic Area (EU/EEA) countries in 2013. Identification of LA-MRSA as clonal complex (CC) 398 by multilocus sequence typing (MLST) was preferred, although surrogate methods such as spa -typing were also accepted. The questionnaire was returned by 28 laboratories in 27 EU/EEA countries. Overall, LA-MRSA represented 3.9% of 13,756 typed MRSA human isolates, but it represented ≥ 10% in five countries (Belgium, Denmark, Spain, the Netherlands and Slovenia). Seven of the reference laboratories did not type MRSA isolates in 2013. To monitor the dispersion of LA-MRSA and facilitate targeted control measures, we advocate periodic systematic surveys or integrated multi-sectorial surveillance.

  8. Armored RNA as Virus Surrogate in a Real-Time Reverse Transcriptase PCR Assay Proficiency Panel

    PubMed Central

    Hietala, S. K.; Crossley, B. M.

    2006-01-01

    In recent years testing responsibilities for high-consequence pathogens have been expanded from national reference laboratories into networks of local and regional laboratories in order to support enhanced disease surveillance and to test for surge capacity. This movement of testing of select agents and high-consequence pathogens beyond reference laboratories introduces a critical need for standardized, noninfectious surrogates of disease agents for use as training and proficiency test samples. In this study, reverse transcription-PCR assay RNA targets were developed and packaged as armored RNA for use as a noninfectious, quantifiable synthetic substitute for four high-consequence animal pathogens: classical swine fever virus; foot-and-mouth disease virus; vesicular stomatitis virus, New Jersey serogroup; and vesicular stomatitis virus, Indiana serogroup. Armored RNA spiked into oral swab fluid specimens mimicked virus-positive clinical material through all stages of the reverse transcription-PCR testing process, including RNA recovery by four different commercial extraction procedures, reverse transcription, PCR amplification, and real-time detection at target concentrations consistent with the dynamic ranges of the existing real-time PCR assays. The armored RNA concentrations spiked into the oral swab fluid specimens were stable under storage conditions selected to approximate the extremes of time and temperature expected for shipping and handling of proficiency panel samples, including 24 h at 37°C and 2 weeks at temperatures ranging from ambient room temperature to −70°C. The analytic test performance, including the reproducibility over the dynamic range of the assays, indicates that armored RNA can provide a noninfectious, quantifiable, and stable virus surrogate for specific assay training and proficiency test purposes. PMID:16390950

  9. Active-Learning Laboratory Session to Teach the Four M's of Diabetes Care

    PubMed Central

    Plake, Kimberly S.; Nash, Christiane L.; Shepler, Brian M.

    2009-01-01

    Objective To implement an active-learning methodology for teaching diabetes care to pharmacy students and evaluate its effectiveness. Design Laboratory instruction was divided into 4 primary areas of diabetes care, referred to by the mnemonic, the 4 M's: meal planning, motion, medication, and monitoring. Students participated in skill-based learning laboratory stations and in simulated patient experiences. A pretest, retrospective pretest, and posttest were administered to measure improvements in students' knowledge about diabetes and confidence in providing care to diabetes patients. Assessment Students knowledge of and confidence in each area assessed improved. Students enjoyed the laboratory session and felt it contributed to their learning. Conclusion An active-learning approach to teaching diabetes care allowed students to experience aspects of the disease from the patient's perspective. This approach will be incorporated in other content areas. PMID:19513160

  10. Whole genome sequencing in clinical and public health microbiology

    PubMed Central

    Kwong, J. C.; McCallum, N.; Sintchenko, V.; Howden, B. P.

    2015-01-01

    SummaryGenomics and whole genome sequencing (WGS) have the capacity to greatly enhance knowledge and understanding of infectious diseases and clinical microbiology. The growth and availability of bench-top WGS analysers has facilitated the feasibility of genomics in clinical and public health microbiology. Given current resource and infrastructure limitations, WGS is most applicable to use in public health laboratories, reference laboratories, and hospital infection control-affiliated laboratories. As WGS represents the pinnacle for strain characterisation and epidemiological analyses, it is likely to replace traditional typing methods, resistance gene detection and other sequence-based investigations (e.g., 16S rDNA PCR) in the near future. Although genomic technologies are rapidly evolving, widespread implementation in clinical and public health microbiology laboratories is limited by the need for effective semi-automated pipelines, standardised quality control and data interpretation, bioinformatics expertise, and infrastructure. PMID:25730631

  11. Whole genome sequencing in clinical and public health microbiology.

    PubMed

    Kwong, J C; McCallum, N; Sintchenko, V; Howden, B P

    2015-04-01

    Genomics and whole genome sequencing (WGS) have the capacity to greatly enhance knowledge and understanding of infectious diseases and clinical microbiology.The growth and availability of bench-top WGS analysers has facilitated the feasibility of genomics in clinical and public health microbiology.Given current resource and infrastructure limitations, WGS is most applicable to use in public health laboratories, reference laboratories, and hospital infection control-affiliated laboratories.As WGS represents the pinnacle for strain characterisation and epidemiological analyses, it is likely to replace traditional typing methods, resistance gene detection and other sequence-based investigations (e.g., 16S rDNA PCR) in the near future.Although genomic technologies are rapidly evolving, widespread implementation in clinical and public health microbiology laboratories is limited by the need for effective semi-automated pipelines, standardised quality control and data interpretation, bioinformatics expertise, and infrastructure.

  12. Reproductive and early life stages pathology - Histopathology workshop report

    USGS Publications Warehouse

    Bruno, D.W.; Nowak, B.; Elliott, Diane G.

    2006-01-01

    Pathology occurring during reproduction and larval development represents an important part of the life cycle of fish, and the diseases that affect eggs and larvae often result in significant losses. However, mortality during this period is frequently ignored or poorly researched as the temptation is to replace the losses rather than investigate the causes. A histopathology workshop organised at the newly refurnished laboratory within the Danish Veterinary School was an opportunity to discuss the pathology of selected diseases associated with Reproductive and Early Life Stages Pathology. Several people also kindly provided reference slides.

  13. Ocular toxoplasmosis in the United States: recent and remote infections.

    PubMed

    Jones, Jeffrey L; Bonetti, Valerie; Holland, Gary N; Press, Cindy; Sanislo, Steven R; Khurana, Rahul N; Montoya, Jose G

    2015-01-15

    We tested all samples from patients with ocular toxoplasmosis sent to the Palo Alto Medical Foundation Toxoplasma Reference Laboratory from June 2004 through August 2010 for serologic evidence of recent Toxoplasma gondii infection. Of 205 patients aged 10-96 years, 11.7% had recent infection. Many people develop ocular disease soon after T. gondii infection. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  14. Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review.

    PubMed

    Earley, Amy; Miskulin, Dana; Lamb, Edmund J; Levey, Andrew S; Uhlig, Katrin

    2012-06-05

    Clinical laboratories are increasingly reporting estimated glomerular filtration rate (GFR) by using serum creatinine assays traceable to a standard reference material. To review the performance of GFR estimating equations to inform the selection of a single equation by laboratories and the interpretation of estimated GFR by clinicians. A systematic search of MEDLINE, without language restriction, between 1999 and 21 October 2011. Cross-sectional studies in adults that compared the performance of 2 or more creatinine-based GFR estimating equations with a reference GFR measurement. Eligible equations were derived or reexpressed and validated by using creatinine measurements traceable to the standard reference material. Reviewers extracted data on study population characteristics, measured GFR, creatinine assay, and equation performance. Eligible studies compared the MDRD (Modification of Diet in Renal Disease) Study and CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equations or modifications thereof. In 12 studies in North America, Europe, and Australia, the CKD-EPI equation performed better at higher GFRs (approximately >60 mL/min per 1.73 m(2)) and the MDRD Study equation performed better at lower GFRs. In 5 of 8 studies in Asia and Africa, the equations were modified to improve their performance by adding a coefficient derived in the local population or removing a coefficient. Methods of GFR measurement and study populations were heterogeneous. Neither the CKD-EPI nor the MDRD Study equation is optimal for all populations and GFR ranges. Using a single equation for reporting requires a tradeoff to optimize performance at either higher or lower GFR ranges. A general practice and public health perspective favors the CKD-EPI equation. Kidney Disease: Improving Global Outcomes.

  15. Validation of a case definition for leptospirosis diagnosis in patients with acute severe febrile disease admitted in reference hospitals at the State of Pernambuco, Brazil.

    PubMed

    Albuquerque Filho, Alfredo Pereira Leite de; Araújo, Jéssica Guido de; Souza, Inacelli Queiroz de; Martins, Luciana Cardoso; Oliveira, Marta Iglis de; Silva, Maria Jesuíta Bezerra da; Montarroyos, Ulisses Ramos; Miranda Filho, Demócrito de Barros

    2011-01-01

    Leptospirosis is often mistaken for other acute febrile illnesses because of its nonspecific presentation. Bacteriologic, serologic, and molecular methods have several limitations for early diagnosis: technical complexity, low availability, low sensitivity in early disease, or high cost. This study aimed to validate a case definition, based on simple clinical and laboratory tests, that is intended for bedside diagnosis of leptospirosis among hospitalized patients. Adult patients, admitted to two reference hospitals in Recife, Brazil, with a febrile illness of less than 21 days and with a clinical suspicion of leptospirosis, were included to test a case definition comprising ten clinical and laboratory criteria. Leptospirosis was confirmed or excluded by a composite reference standard (microscopic agglutination test, ELISA, and blood culture). Test properties were determined for each cutoff number of the criteria from the case definition. Ninety seven patients were included; 75 had confirmed leptospirosis and 22 did not. Mean number of criteria from the case definition that were fulfilled was 7.8±1.2 for confirmed leptospirosis and 5.9±1.5 for non-leptospirosis patients (p<0.0001). Best sensitivity (85.3%) and specificity (68.2%) combination was found with a cutoff of 7 or more criteria, reaching positive and negative predictive values of 90.1% and 57.7%, respectively; accuracy was 81.4%. The case definition, for a cutoff of at least 7 criteria, reached average sensitivity and specificity, but with a high positive predictive value. Its simplicity and low cost make it useful for rapid bedside leptospirosis diagnosis in Brazilian hospitalized patients with acute severe febrile disease.

  16. The European network of Biosafety-Level-4 laboratories: enhancing European preparedness for new health threats.

    PubMed

    Nisii, C; Castilletti, C; Di Caro, A; Capobianchi, M R; Brown, D; Lloyd, G; Gunther, S; Lundkvist, A; Pletschette, M; Ippolito, G

    2009-08-01

    Emerging and re-emerging infections and possible bioterrorism acts will continue to challenge both the medical community and civilian populations worldwide, urging health authorities to respond rapidly and effectively. Established in 2005, the European Community (EC)-funded European Network of Biosafety-Level-4 laboratories (Euronet-P4), which brings together the laboratories in Porton Down, London, Hamburg, Marburg, Solna, Lyon and Rome, seeks to increase international collaboration in the areas of high containment laboratory biosafety and viral diagnostic capability, to strengthen Europe's capacity to respond to an infectious disease emergency, and to offer assistance to countries not equipped with such costly facilities. Network partners have agreed on a common strategy to fill the gaps identified in the field of risk group-4 agents' laboratory diagnosis, namely the lack of standardization and of reference samples. The network has received a further 3-year funding, to offer assistance to external laboratories, and to start the planning of field activities.

  17. Identification of Medically Actionable Secondary Findings in the 1000 Genomes

    PubMed Central

    Olfson, Emily; Cottrell, Catherine E.; Davidson, Nicholas O.; Gurnett, Christina A.; Heusel, Jonathan W.; Stitziel, Nathan O.; Chen, Li-Shiun; Hartz, Sarah; Nagarajan, Rakesh; Saccone, Nancy L.; Bierut, Laura J.

    2015-01-01

    The American College of Medical Genetics and Genomics (ACMG) recommends that clinical sequencing laboratories return secondary findings in 56 genes associated with medically actionable conditions. Our goal was to apply a systematic, stringent approach consistent with clinical standards to estimate the prevalence of pathogenic variants associated with such conditions using a diverse sequencing reference sample. Candidate variants in the 56 ACMG genes were selected from Phase 1 of the 1000 Genomes dataset, which contains sequencing information on 1,092 unrelated individuals from across the world. These variants were filtered using the Human Gene Mutation Database (HGMD) Professional version and defined parameters, appraised through literature review, and examined by a clinical laboratory specialist and expert physician. Over 70,000 genetic variants were extracted from the 56 genes, and filtering identified 237 variants annotated as disease causing by HGMD Professional. Literature review and expert evaluation determined that 7 of these variants were pathogenic or likely pathogenic. Furthermore, 5 additional truncating variants not listed as disease causing in HGMD Professional were identified as likely pathogenic. These 12 secondary findings are associated with diseases that could inform medical follow-up, including cancer predisposition syndromes, cardiac conditions, and familial hypercholesterolemia. The majority of the identified medically actionable findings were in individuals from the European (5/379) and Americas (4/181) ancestry groups, with fewer findings in Asian (2/286) and African (1/246) ancestry groups. Our results suggest that medically relevant secondary findings can be identified in approximately 1% (12/1092) of individuals in a diverse reference sample. As clinical sequencing laboratories continue to implement the ACMG recommendations, our results highlight that at least a small number of potentially important secondary findings can be selected for return. Our results also confirm that understudied populations will not reap proportionate benefits of genomic medicine, highlighting the need for continued research efforts on genetic diseases in these populations. PMID:26332594

  18. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  19. [The role of reference laboratories in animal health programmes in South America].

    PubMed

    Bergmann, I E

    2003-08-01

    The contribution of the Panamerican Foot and Mouth Disease (FMD) Centre (PANAFTOSA), as an OIE (World organisation for animal health) regional reference laboratory for the diagnosis of FMD and vesicular stomatitis, and for the control of the FMD vaccine, has been of fundamental importance to the development, implementation and harmonisation of modern laboratory procedures in South America. The significance of the work conducted by PANAFTOSA is particularly obvious when one considers the two pillars on which eradication programmes are based, namely: a well-structured regional laboratory network, and the creation of a system which allows technology and new developments to be transferred to Member Countries as quickly and efficiently as possible. Over the past decade, PANAFTOSA has kept pace with the changing epidemiological situation on the continent, and with developments in the international political and economical situation. This has involved the strengthening of quality policies, and the elaboration and implementation of diagnostic tools that make for more thorough epidemiological analyses. The integration of PANAFTOSA into the network of national laboratories and its cooperation with technical and scientific institutes, universities and the private sector means that local needs can be met, thanks to the design and rapid implementation of methodological tools which are validated using internationally accepted criteria. This collaboration, which ensures harmonisation of laboratory tests and enhances the quality of national Veterinary Services, serves to promote greater equity, a prerequisite for regional eradication strategies and this in turn, helps to increase competitiveness in the region.

  20. Safe and cost-effective protocol for shipment of samples from Foot-and-Mouth Disease suspected cases for laboratory diagnostic.

    PubMed

    Romey, A; Relmy, A; Gorna, K; Laloy, E; Zientara, S; Blaise-Boisseau, S; Bakkali Kassimi, L

    2018-02-01

    An essential step towards the global control and eradication of foot-and-mouth disease (FMD) is the identification of circulating virus strains in endemic regions to implement adequate outbreak control measures. However, due to the high biological risk and the requirement for biological samples to be shipped frozen, the cost of shipping samples becomes one of major obstacles hindering submission of suspected samples to reference laboratories for virus identification. In this study, we report the development of a cost-effective and safe method for shipment of FMD samples. The protocol is based on the inactivation of FMD virus (FMDV) on lateral flow device (LFD, penside test routinely used in the field for rapid immunodetection of FMDV), allowing its subsequent detection and typing by RT-PCR and recovery of live virus upon RNA transfection into permissive cells. After live FMDV collection onto LFD strip and soaking in 0.2% citric acid solution, the virus is totally inactivated. Viral RNA is still detectable by real-time RT-PCR following inactivation, and the virus strain can be characterized by sequencing of the VP1 coding region. In addition, live virus can be rescued by transfecting RNA extract from treated LFD into cells. This protocol should help promoting submission of FMD suspected samples to reference laboratories (by reducing the cost of sample shipping) and thus characterization of FMDV strains circulating in endemic regions. © 2017 Blackwell Verlag GmbH.

  1. Impact of RNA Degradation on Viral Diagnosis: An Understated but Essential Step for the Successful Establishment of a Diagnosis Network

    PubMed Central

    Relova, Damarys; Acevedo, Ana M.; Coronado, Liani; Perera, Carmen L.

    2018-01-01

    The current global conditions, which include intensive globalization, climate changes, and viral evolution among other factors, have led to an increased emergence of viruses and new viral diseases; RNA viruses are key drivers of this evolution. Laboratory networks that are linked to central reference laboratories are required to conduct both active and passive environmental surveillance of this complicated global viral environment. These tasks require a continuous exchange of strains or field samples between different diagnostic laboratories. The shipment of these samples on dry ice represents both a biological hazard and a general health risk. Moreover, the requirement to ship on dry ice could be hampered by high costs, particularly in underdeveloped countries or regions located far from each other. To solve these issues, the shipment of RNA isolated from viral suspensions or directly from field samples could be a useful way to share viral genetic material. However, extracted RNA stored in aqueous solutions, even at −70 °C, is highly prone to degradation. The current study evaluated different RNA storage conditions for safety and feasibility for future use in molecular diagnostics. The in vitro RNA-transcripts obtained from an inactivated highly pathogenic avian influenza (HPAI) H5N1 virus was used as a model. The role of secondary structures in the protection of the RNA was also explored. Of the conditions evaluated, the dry pellet matrix was best able to protect viral RNA under extreme storage conditions. This method is safe, cost-effective and assures the integrity of RNA samples for reliable molecular diagnosis. This study aligns with the globally significant “Global One Health” paradigm, especially with respect to the diagnosis of emerging diseases that require confirmation by reference laboratories. PMID:29415432

  2. A composite CBRN surveillance and testing service

    NASA Astrophysics Data System (ADS)

    Niemeyer, Debra M.

    2004-08-01

    The terrorist threat coupled with a global military mission necessitates quick and accurate identification of environmental hazards, and CBRN early warning. The Air Force Institute for Operational Health (AFIOH) provides fundamental support to protect personnel from and mitigate the effects of untoward hazards exposures. Sustaining healthy communities since 1955, the organizational charter is to enhance warfighter mission effectiveness, protect health, improve readiness and reduce costs, assess and manage risks to human heath and safety, operational performance and the environment. The AFIOH Surveillance Directorate provides forward deployed and reach-back surveillance, agent identification, and environ-mental regulatory compliance testing. Three unique laboratories process and analyze over two million environmental samples and clinical specimens per year, providing analytical chemistry, radiological assessment, and infectious disease testing, in addition to supporting Air Force and Department of Defense (DoD) clinical reference laboratory and force health protection testing. Each laboratory has an applied or investigational testing section where new technologies and techniques are evaluated, and expert consultative support to assist in technology assessments and test analyses. The Epidemiology Surveillance Laboratory and Analytical Chemistry Laboratory are critical assets of the Centers for Disease Control and Prevention (CDC) National Laboratory Response Network. Deployable assets provide direct support to the Combatant Commander and include the Air Force Radiological Assessment Team, and the Biological Augmentation Team. A diverse directorate, the synergistic CBRN response capabilities are a commander"s force protection tool, critical to maintaining combat power.

  3. Determination of reference ranges for elements in human scalp hair.

    PubMed

    Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W

    1998-06-01

    Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.

  4. Experimenting with Spirituality: Analyzing "The God Gene" in a Nonmajors Laboratory Course

    ERIC Educational Resources Information Center

    Silveira, Linda A.

    2008-01-01

    References linking genes to complex human traits, such as personality type or disease susceptibility, abound in the news media and popular culture. In his book "The God Gene: How Faith is Hardwired into Our Genes", Dean Hamer argues that a variation in the "VMAT2" gene plays a role in one's openness to spiritual experiences. In a nonmajors class,…

  5. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  6. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  7. Development of a Genomic DNA Reference Material Panel for Myotonic Dystrophy Type 1 (DM1) Genetic Testing

    PubMed Central

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine

    2014-01-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132

  8. Malignant diseases of hematopoietic and lymphoid tissues in Chernobyl clean-up workers.

    PubMed

    Gluzman, Daniel; Imamura, Nobutaka; Sklyarenko, Lylia; Nadgornaya, Valentina; Zavelevich, Michael; Machilo, Vasily

    2005-01-01

    The question as to whether the incidence of leukemias and malignant lymphomas among the clean-up workers increased in 18 years after the catastrophe is still a point of much controversy. Precise diagnosis of the main forms of hematopoietic malignancies and comparison of these data with those in the general population will be helpful in estimating thr relative contribution of the radiation factor to the overall incidence of such pathologies. In all, 187 consecutive cases of malignant diseases of hematopoietic and lymphoid tissues in Chernobyl clean-up workers were analyzed in Ukrainian Reference Laboratory in 1996-2003. A total of 1942 consecutive patients of general population, mainly the residents of Kyiv city and district, diagnosed in References Laboratory at the same period comprised the group of comparison. The morphology and cytochemistry of bone marrow and peripheral blood cells were studied. Immunocytochemical techniques (PAP, APAAP, ABC) and the panel of monoclonal antibodies to differentiation antigens of leukocytes were employed for immunophenotyping leukemic cells. Various types of malignant disease of hematopoietic and lymphoid tissues were registered in Chernobyl clean-up workers under study including myelodysplastic syndromes (nine patients), acute lymphoblastic leukemia (eight) and acute myeloblastic leukemia (31), chromic myeloid leukemia (17), multiple myeloma (17) and other forms of chromic myeloproliferative and lymphoproliferative disease including B-cell chromic lymphocytic leukemia (49 patients). The verified diagnosis of tumors of hematopoietic malignancies according to modern classification (EGIL, WHO) could be the prerequisite for further analytical epidemiology study of leukemias that may be related to the Chernobyl accident.

  9. Quality assurance in the HIV/AIDS laboratory network of China.

    PubMed

    Jiang, Yan; Qiu, Maofeng; Zhang, Guiyun; Xing, Wenge; Xiao, Yao; Pan, Pinliang; Yao, Jun; Ou, Chin-Yih; Su, Xueli

    2010-12-01

    In 2009, there were 8273 local screening laboratories, 254 confirmatory laboratories, 35 provincial confirmatory central laboratories and 1 National AIDS Reference Laboratory (NARL) in China. These laboratories were located in Center for Disease Control and Prevention (CDC) facilities, hospitals, blood donation clinics, maternal and child health (MCH) hospitals and border health quarantine health-care facilities. The NARL and provincial laboratories provide quality assurance through technical, bio-safety and managerial training; periodic proficiency testing; on-site supervisory inspections; and commercial serologic kit evaluations. From 2002 to 2009, more than 220 million HIV antibody tests were performed at screening laboratories, and all reactive and indeterminate samples were confirmed at confirmatory laboratories. The use of highly technically complex tests, including CD4 cell enumeration, viral load, dried blood spot (DBS)-based early infant diagnosis (EID), drug resistance (DR) genotyping, HIV-1 subtyping and incidence assays, have increased in recent years and their performance quality is closely monitored. China has made significant progress in establishing a well-coordinated HIV laboratory network and QA systems. However, the coverage and intensity of HIV testing and quality assurance programmes need to be strengthened so as to ensure that more infected persons are diagnosed and that they receive timely prevention and treatment services.

  10. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  11. Parents of children referred to a sleep laboratory for disordered breathing reported anxiety, daytime sleepiness and poor sleep quality.

    PubMed

    Cadart, Marion; De Sanctis, Livio; Khirani, Sonia; Amaddeo, Alessandro; Ouss, Lisa; Fauroux, Brigitte

    2018-07-01

    We evaluated the impact that having a child with sleep-disordered breathing had on their parents, including their own sleep quality. Questionnaires were completed by 96 parents of 86 children referred for a sleep study or control of continuous positive airway pressure (CPAP) or noninvasive ventilation (NIV) at the sleep laboratory of the Necker Hospital, Paris, France, between October 2015 and January 2016. The questionnaires evaluated anxiety and depression, family functioning, the parents' quality of life, daytime sleepiness and sleep quality. The children had a mean age of seven ±five years and most of the responses (79%) came from their mothers. These showed that 26% of parents showed moderate-to-severe anxiety, 8% moderate-to-severe depression, 6% complex family cohesion, 59% moderate-to-severe daytime sleepiness and 54% poor sleep quality. Anxiety was higher in mothers than in fathers (p < 0.001). The questionnaire scores did not differ according to the child's age, the results of the sleep studies or the CPAP or NIV treatment. The symptoms seem to be more commonly related to the child's underlying disease than their sleep-disordered breathing. The parents of children referred to a sleep laboratory reported frequent anxiety, daytime sleepiness and poor sleep quality. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  12. Laboratory-based surveillance of Neisseria meningitidis isolates from disease cases in Latin American and Caribbean countries, SIREVA II 2006-2010.

    PubMed

    Ibarz-Pavón, Ana Belén; Lemos, Ana Paula; Gorla, Maria Cecilia; Regueira, Mabel; Gabastou, Jean-Marc

    2012-01-01

    Published data on the epidemiology of meningococcal disease in Latin America and the Caribbean region is scarce and, when available, it is often published in Spanish and/or in non-peer-reviewed journals, making it difficult for the international scientific community to have access. Laboratory data on 4,735 Neisseria meningitidis strains was collected and reported by the National Reference Laboratories in 19 Latin American countries and the Caribbean Epidemiology Centre (CAREC) between 2006 and 2010 as part of the work carried out by the SIREVA II network. Serogroup and MIC to penicillin, rifampin and chloramphenicol were determined. Isolates were mainly obtained from patients <5 years, but each year around 25% of isolates came from adult patients. Serogroup distribution was highly variable among countries. Serogroup C was the main cause of disease in Brazil; the majority of disease seen in the Southern cone was caused by serogroup B, but serogroup W135 strains have increased in recent years. In the Andean and Mexico, Central America and Caribbean regions, serogroups B and C were equally present, and serogroup Y was frequently isolated. Isolates were generally susceptible to chloramphenicol, penicillin and rifampin, but almost 60% of isolates characterized in Southern cone countries presented intermediate resistance to penicillin. Five rifampin-resistant isolates have been isolated in Uruguay and Brazil. Serogroup distribution is highly variable among countries, but some geographic structuring can be inferred from these data. Epidemiological and laboratory data are scarce among Andean and Mexico, Central America and Caribbean countries. Evaluation and implementation of corrective measures on disease surveillance and reporting systems and the implementation of molecular diagnostic techniques and molecular characterization on meningococcal isolates are advised.

  13. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    PubMed Central

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  14. The Effect of Positive Family History of Autoimmunity in Juvenile Idiopathic Arthritis Characteristics; a Case Control Study

    PubMed Central

    Khani, Mehdi; Ziaee, Vahid; Moradinejad, Mohamad-Hassan; Parvaneh, Nima

    2013-01-01

    Objective To compare Juvenile Idiopathic Arthritis (JIA) patients with and without family history of autoimmune disease with respect to clinical features and laboratory data. Methods Sixteen JIA patients with family history of autoimmune disease were identified during study, 32 patients were chosen for comparative group from referred patients to the rheumatology clinic according to the date of referral. Two groups were compared with respect to age of onset, sex, subtype, disease activity, duration of active disease and laboratory variables. Findings The age of onset was significantly lower in JIA patients with family history of autoimmunity (4.7 years vs. 7.0 years; P=0.02), polyarthicular subtype was more frequent in patients with positive family history (50% vs.25%; P=0.04) most of JIA patients with positive family history were in the active phase at the time of study (64% vs 25%; P=0.02) and had a longer duration of active disease (21.0 months vs 12.3 months; P=0.04). Patients with positive family history had more positive ANA (43.5%% vs 12.5%; P=0.01) and also more positive ADA (75% vs 20.8%; P=0.002). Two groups were similar according to sex, and other laboratory variables. Conclusion JIA patients with family history of autoimmune disease seem to have a more severe disease than patients without such family history, they are younger at the onset, and have mostly poyarthicular subtype. They also have more ANA and ADA positivity. These findings are different from familial JIA case-control studies according to active disease duration, subtype, and ANA positivity. PMID:24800019

  15. Molecular digital pathology: progress and potential of exchanging molecular data.

    PubMed

    Roy, Somak; Pfeifer, John D; LaFramboise, William A; Pantanowitz, Liron

    2016-09-01

    Many of the demands to perform next generation sequencing (NGS) in the clinical laboratory can be resolved using the principles of telepathology. Molecular telepathology can allow facilities to outsource all or a portion of their NGS operation such as cloud computing, bioinformatics pipelines, variant data management, and knowledge curation. Clinical pathology laboratories can electronically share diverse types of molecular data with reference laboratories, technology service providers, and/or regulatory agencies. Exchange of electronic molecular data allows laboratories to perform validation of rare diseases using foreign data, check the accuracy of their test results against benchmarks, and leverage in silico proficiency testing. This review covers the emerging subject of molecular telepathology, describes clinical use cases for the appropriate exchange of molecular data, and highlights key issues such as data integrity, interoperable formats for massive genomic datasets, security, malpractice and emerging regulations involved with this novel practice.

  16. Mapping of the US Domestic Influenza Virologic Surveillance Landscape.

    PubMed

    Jester, Barbara; Schwerzmann, Joy; Mustaquim, Desiree; Aden, Tricia; Brammer, Lynnette; Humes, Rosemary; Shult, Pete; Shahangian, Shahram; Gubareva, Larisa; Xu, Xiyan; Miller, Joseph; Jernigan, Daniel

    2018-07-17

    Influenza virologic surveillance is critical each season for tracking influenza circulation, following trends in antiviral drug resistance, detecting novel influenza infections in humans, and selecting viruses for use in annual seasonal vaccine production. We developed a framework and process map for characterizing the landscape of US influenza virologic surveillance into 5 tiers of influenza testing: outpatient settings (tier 1), inpatient settings and commercial laboratories (tier 2), state public health laboratories (tier 3), National Influenza Reference Center laboratories (tier 4), and Centers for Disease Control and Prevention laboratories (tier 5). During the 2015-16 season, the numbers of influenza tests directly contributing to virologic surveillance were 804,000 in tiers 1 and 2; 78,000 in tier 3; 2,800 in tier 4; and 3,400 in tier 5. With the release of the 2017 US Pandemic Influenza Plan, the proposed framework will support public health officials in modeling, surveillance, and pandemic planning and response.

  17. A guide to utilization of the microbiology laboratory for diagnosis of infectious diseases: 2013 recommendations by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM)(a).

    PubMed

    Baron, Ellen Jo; Miller, J Michael; Weinstein, Melvin P; Richter, Sandra S; Gilligan, Peter H; Thomson, Richard B; Bourbeau, Paul; Carroll, Karen C; Kehl, Sue C; Dunne, W Michael; Robinson-Dunn, Barbara; Schwartzman, Joseph D; Chapin, Kimberle C; Snyder, James W; Forbes, Betty A; Patel, Robin; Rosenblatt, Jon E; Pritt, Bobbi S

    2013-08-01

    The critical role of the microbiology laboratory in infectious disease diagnosis calls for a close, positive working relationship between the physician and the microbiologists who provide enormous value to the health care team. This document, developed by both laboratory and clinical experts, provides information on which tests are valuable and in which contexts, and on tests that add little or no value for diagnostic decisions. Sections are divided into anatomic systems, including Bloodstream Infections and Infections of the Cardiovascular System, Central Nervous System Infections, Ocular Infections, Soft Tissue Infections of the Head and Neck, Upper Respiratory Infections, Lower Respiratory Tract infections, Infections of the Gastrointestinal Tract, Intraabdominal Infections, Bone and Joint Infections, Urinary Tract Infections, Genital Infections, and Skin and Soft Tissue Infections; or into etiologic agent groups, including Tickborne Infections, Viral Syndromes, and Blood and Tissue Parasite Infections. Each section contains introductory concepts, a summary of key points, and detailed tables that list suspected agents; the most reliable tests to order; the samples (and volumes) to collect in order of preference; specimen transport devices, procedures, times, and temperatures; and detailed notes on specific issues regarding the test methods, such as when tests are likely to require a specialized laboratory or have prolonged turnaround times. There is redundancy among the tables and sections, as many agents and assay choices overlap. The document is intended to serve as a reference to guide physicians in choosing tests that will aid them to diagnose infectious diseases in their patients.

  18. Executive summary: a guide to utilization of the microbiology laboratory for diagnosis of infectious diseases: 2013 recommendations by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM)(a).

    PubMed

    Baron, Ellen Jo; Miller, J Michael; Weinstein, Melvin P; Richter, Sandra S; Gilligan, Peter H; Thomson, Richard B; Bourbeau, Paul; Carroll, Karen C; Kehl, Sue C; Dunne, W Michael; Robinson-Dunn, Barbara; Schwartzman, Joseph D; Chapin, Kimberle C; Snyder, James W; Forbes, Betty A; Patel, Robin; Rosenblatt, Jon E; Pritt, Bobbi S

    2013-08-01

    The critical role of the microbiology laboratory in infectious disease diagnosis calls for a close, positive working relationship between the physician and the microbiologists who provide enormous value to the health care team. This document, developed by both laboratory and clinical experts, provides information on which tests are valuable and in which contexts, and on tests that add little or no value for diagnostic decisions. Sections are divided into anatomic systems, including Bloodstream Infections and Infections of the Cardiovascular System, Central Nervous System Infections, Ocular Infections, Soft Tissue Infections of the Head and Neck, Upper Respiratory Infections, Lower Respiratory Tract infections, Infections of the Gastrointestinal Tract, Intraabdominal Infections, Bone and Joint Infections, Urinary Tract Infections, Genital Infections, and Skin and Soft Tissue Infections; or into etiologic agent groups, including Tickborne Infections, Viral Syndromes, and Blood and Tissue Parasite Infections. Each section contains introductory concepts, a summary of key points, and detailed tables that list suspected agents; the most reliable tests to order; the samples (and volumes) to collect in order of preference; specimen transport devices, procedures, times, and temperatures; and detailed notes on specific issues regarding the test methods, such as when tests are likely to require a specialized laboratory or have prolonged turnaround times. There is redundancy among the tables and sections, as many agents and assay choices overlap. The document is intended to serve as a reference to guide physicians in choosing tests that will aid them to diagnose infectious diseases in their patients.

  19. A Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2013 Recommendations by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM)a

    PubMed Central

    Baron, Ellen Jo; Miller, J. Michael; Weinstein, Melvin P.; Richter, Sandra S.; Gilligan, Peter H.; Thomson, Richard B.; Bourbeau, Paul; Carroll, Karen C.; Kehl, Sue C.; Dunne, W. Michael; Robinson-Dunn, Barbara; Schwartzman, Joseph D.; Chapin, Kimberle C.; Snyder, James W.; Forbes, Betty A.; Patel, Robin; Rosenblatt, Jon E.; Pritt, Bobbi S.

    2013-01-01

    The critical role of the microbiology laboratory in infectious disease diagnosis calls for a close, positive working relationship between the physician and the microbiologists who provide enormous value to the health care team. This document, developed by both laboratory and clinical experts, provides information on which tests are valuable and in which contexts, and on tests that add little or no value for diagnostic decisions. Sections are divided into anatomic systems, including Bloodstream Infections and Infections of the Cardiovascular System, Central Nervous System Infections, Ocular Infections, Soft Tissue Infections of the Head and Neck, Upper Respiratory Infections, Lower Respiratory Tract infections, Infections of the Gastrointestinal Tract, Intraabdominal Infections, Bone and Joint Infections, Urinary Tract Infections, Genital Infections, and Skin and Soft Tissue Infections; or into etiologic agent groups, including Tickborne Infections, Viral Syndromes, and Blood and Tissue Parasite Infections. Each section contains introductory concepts, a summary of key points, and detailed tables that list suspected agents; the most reliable tests to order; the samples (and volumes) to collect in order of preference; specimen transport devices, procedures, times, and temperatures; and detailed notes on specific issues regarding the test methods, such as when tests are likely to require a specialized laboratory or have prolonged turnaround times. There is redundancy among the tables and sections, as many agents and assay choices overlap. The document is intended to serve as a reference to guide physicians in choosing tests that will aid them to diagnose infectious diseases in their patients. PMID:23845951

  20. Direct detection and characterization of foot-and-mouth disease virus in East Africa using a field-ready real-time PCR platform.

    PubMed

    Howson, E L A; Armson, B; Lyons, N A; Chepkwony, E; Kasanga, C J; Kandusi, S; Ndusilo, N; Yamazaki, W; Gizaw, D; Cleaveland, S; Lembo, T; Rauh, R; Nelson, W M; Wood, B A; Mioulet, V; King, D P; Fowler, V L

    2018-02-01

    Effective control and monitoring of foot-and-mouth disease (FMD) relies upon rapid and accurate disease confirmation. Currently, clinical samples are usually tested in reference laboratories using standardized assays recommended by The World Organisation for Animal Health (OIE). However, the requirements for prompt and serotype-specific diagnosis during FMD outbreaks, and the need to establish robust laboratory testing capacity in FMD-endemic countries have motivated the development of simple diagnostic platforms to support local decision-making. Using a portable thermocycler, the T-COR™ 8, this study describes the laboratory and field evaluation of a commercially available, lyophilized pan-serotype-specific real-time RT-PCR (rRT-PCR) assay and a newly available FMD virus (FMDV) typing assay (East Africa-specific for serotypes: O, A, Southern African Territories [SAT] 1 and 2). Analytical sensitivity, diagnostic sensitivity and specificity of the pan-serotype-specific lyophilized assay were comparable to that of an OIE-recommended laboratory-based rRT-PCR (determined using a panel of 57 FMDV-positive samples and six non-FMDV vesicular disease samples for differential diagnosis). The FMDV-typing assay was able to correctly identify the serotype of 33/36 FMDV-positive samples (no cross-reactivity between serotypes was evident). Furthermore, the assays were able to accurately detect and type FMDV RNA in multiple sample types, including epithelial tissue suspensions, serum, oesophageal-pharyngeal (OP) fluid and oral swabs, both with and without the use of nucleic acid extraction. When deployed in laboratory and field settings in Tanzania, Kenya and Ethiopia, both assays reliably detected and serotyped FMDV RNA in samples (n = 144) collected from pre-clinical, clinical and clinically recovered cattle. These data support the use of field-ready rRT-PCR platforms in endemic settings for simple, highly sensitive and rapid detection and/or characterization of FMDV. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  1. Improved Specimen-Referral System and Increased Access to Quality Laboratory Services in Ethiopia: The Role of the Public-Private Partnership.

    PubMed

    Kebede, Yenew; Fonjungo, Peter N; Tibesso, Gudeta; Shrivastava, Ritu; Nkengasong, John N; Kenyon, Thomas; Kebede, Amha; Gadde, Renuka; Ayana, Gonfa

    2016-04-15

    Nonstandardized specimen-transport logistics, lack of laboratory personnel to transport specimens, lack of standard specimen containers, and long turnaround time (TAT) hindered access to quality laboratory services. The objective of the Becton, Dickinson, and Company (BD)-US President's Emergency Plan for AIDS Relief (PEPFAR) Public-Private Partnership (PPP) was to support country-specific programs to develop integrated laboratory systems, services, and quality improvement strategies, with an emphasis on strengthening the specimen-referral system (SRS). In 2007, through the Centers for Disease Control and Prevention (CDC), the Ethiopian Public Health Institute (EPHI) joined with the BD-PEPFAR PPP to strengthen laboratory systems. A joint planning and assessment committee identified gaps in the SRS for prioritization and intervention and piloted the system in Addis Ababa and Amhara Region. The PPP established standardized, streamlined specimen logistics, using the Ethiopian Postal Service Enterprise to support a laboratory network in which 554 facilities referred specimens to 160 laboratories. The PPP supported procuring 400 standard specimen containers and the training of 586 laboratory personnel and 81 postal workers. The average TAT was reduced from 7 days (range, 2-14 days) to 2 days (range, 1-3 days) in Addis Ababa and from 10 days (range, 6-21 days) to 5 days (range, 2-6 days) in Amhara Region. This study highlights the feasibility and untapped potential of PPPs to strengthen laboratory systems. This planned and structured approach to improving specimen referral enhanced access to quality laboratory services. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  2. First Definition of Reference Intervals of Liver Function Tests in China: A Large-Population-Based Multi-Center Study about Healthy Adults

    PubMed Central

    Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie

    2013-01-01

    Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449

  3. Validation conform ISO-15189 of assays in the field of autoimmunity: Joint efforts in The Netherlands.

    PubMed

    Mulder, Leontine; van der Molen, Renate; Koelman, Carin; van Leeuwen, Ester; Roos, Anja; Damoiseaux, Jan

    2018-05-01

    ISO 15189:2012 requires validation of methods used in the medical laboratory, and lists a series of performance parameters for consideration to include. Although these performance parameters are feasible for clinical chemistry analytes, application in the validation of autoimmunity tests is a challenge. Lack of gold standards or reference methods in combination with the scarcity of well-defined diagnostic samples of patients with rare diseases make validation of new assays difficult. The present manuscript describes the initiative of Dutch medical immunology laboratory specialists to combine efforts and perform multi-center validation studies of new assays in the field of autoimmunity. Validation data and reports are made available to interested Dutch laboratory specialists. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.

    PubMed

    Jones, Graham R D; Jackson, Craig

    2016-01-30

    The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Transport equations of electrodiffusion processes in the laboratory reference frame.

    PubMed

    Garrido, Javier

    2006-02-23

    The transport equations of electrodiffusion processes use three reference frames for defining the fluxes: Fick's reference in diffusion, solvent-fixed reference in transference numbers, and laboratory fluxes in electric conductivity. The convenience of using only one reference frame is analyzed here from the point of view of the thermodynamics of irreversible processes. A relation between the fluxes of ions and solvent and the electric current density is deduced first from a mass and volume balance. This is then used to show that (i) the laboratory and Fick's diffusion coefficients are identical and (ii) the transference numbers of both the solvent and the ion in the laboratory reference frame are related. Finally, four experimental methods for the measurement of ion transference numbers are analyzed critically. New expressions for evaluating transference numbers for the moving boundary method and the chronopotentiometry technique are deduced. It is concluded that the ion transport equation in the laboratory reference frame plays a key role in the description of electrodiffusion processes.

  6. Enteric Disease Surveillance Under the AFHSC-GEIS: Current Efforts, Landscape Analysis and Vision Forward

    DTIC Science & Technology

    2011-01-01

    Severe diarrhea study at Cairo University • Case-control study of modifiable risk behaviors • Molecular biology and cholera/ rotavirus microbiology...capacity as WHO Rotavirus Reference Laboratory • Norovirus outbreak response support, Incirlik Air Base, Turkey NMRCD-Peru • Cohort study among basic...identified rotavirus as the leading causative agent • Advanced characterization of Campylobacter spp. and Shigella spp. USAMRU-K • Movement of Enteric

  7. Managing a cluster outbreak of psittacosis in Belgium linked to a pet shop visit in The Netherlands.

    PubMed

    DE Boeck, C; Dehollogne, C; Dumont, A; Spierenburg, M; Heijne, M; Gyssens, I; VAN DER Hilst, J; Vanrompay, D

    2016-06-01

    In July 2013, a Belgian couple were admitted to hospital because of pneumonia. Medical history revealed contact with birds. Eleven days earlier, they had purchased a lovebird in a pet shop in The Netherlands. The bird became ill, with respiratory symptoms. The couple's daughter who accompanied them to the pet shop, reported similar symptoms, but was travelling abroad. On the suspicion of psittacosis, pharyngeal swabs from the couple were taken and sent to the Belgian reference laboratory for psittacosis. Culture and nested polymerase chain reaction (PCR) tests were positive for the presence of Chlamydia psittaci, and ompA genotyping indicated genotype A in both patients. The patients were treated with doxycycline and the daughter started quinolone therapy; all three recovered promptly. Psittacosis is a notifiable disease in Belgium and therefore local healthcare authorities were informed. They contacted their Dutch colleagues, who visited the pet shop. Seven pooled faecal samples were taken and analysed using PCR by the Dutch national reference laboratory for notifiable animal diseases for the presence of Chlamydia psittaci. Four (57%) samples tested positive, genotyping revealed genotype A. Enquiring about exposure to pet birds is essential when patients present with pneumonia. Reporting to health authorities, even across borders, is warranted to prevent further spread.

  8. Detection of erythrovirus B19 in thyroidectomy specimens from Graves' disease patients: a case-control study.

    PubMed

    Page, Cyril; Hoffmann, Thomas Walter; Benzerdjeb, Nassim; Duverlie, Gilles; Sevestre, Henri; Desailloud, Rachel

    2013-08-01

    Environmental factors, such as viruses, are thought to contribute to the development of thyroid autoimmunity. Erythrovirus B19 (EVB19) is suspected to be involved in Hashimoto's thyroiditis, but no direct evidence is available concerning the role of EVB19 infection in Graves' disease. The objective of this study was to investigate whether the presence of EVB19 is more frequent in thyroidectomy specimens of patients undergoing thyroidectomy for Graves' disease (cases) than for multinodular thyroid (controls). Serum and thyroidectomy specimens were prospectively collected from 64 patients referred for total thyroidectomy over a 5-year period (2007-2011) and were investigated retrospectively and blindly for circulating EVB19 DNA by q-PCR (Qiagen), and for EVB19 thyrocyte infection by immunochemistry (VP2-Antibody, Dako). EVB19 serology was also determined. General clinical and laboratory data were collected. Twenty patients were referred for Graves' disease and 44 patients were referred for non-autoimmune multinodular thyroid. Patients with thyroid cancer were excluded. Ten percent of Graves' disease patients and 27.7% of control patients had positive staining of thyrocytes for EVB19 antibodies (ns). EVB19-positive and EVB19-negative cases did not differ. EVB19-positive controls were older than EVB19-negative controls (mean age: 57.5 [35-74] vs. 45 [28-80] years, P=0.03) No case of acute EVB19 infection was identified. EVB19-positive serology was more frequent in controls than in Graves' disease patients (88% vs. 45%, P<0.0001). EVB19 was detected in thyrocytes, but not more frequently in Graves' disease patients than in controls. Further studies are needed to determine the role of EVB19 infection in thyroid diseases. Copyright © 2013 Wiley Periodicals, Inc.

  9. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method.

    PubMed

    Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz

    2017-01-01

    High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.

  10. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.

    PubMed

    Higgins, Victoria; Chan, Man Khun; Nieuwesteeg, Michelle; Hoffman, Barry R; Bromberg, Irvin L; Gornall, Doug; Randell, Edward; Adeli, Khosrow

    2016-01-01

    The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has recently established pediatric age- and sex-specific reference intervals for over 85 biochemical markers on the Abbott Architect system. Previously, CALIPER reference intervals for several biochemical markers were successfully transferred from Abbott assays to Roche, Beckman, Ortho, and Siemens assays. This study further broadens the CALIPER database by performing transference and verification for 52 biochemical assays on the Roche cobas 6000 and the Roche Modular P. Using CLSI C28-A3 and EP9-A2 guidelines, transference of the CALIPER reference intervals was attempted for 16 assays on the Roche cobas 6000 and 36 on the Modular P. Calculated reference intervals were further verified using 100 healthy CALIPER samples. Most assays showed strong correlation between assay systems and were transferable from Abbott to the Roche cobas 6000 (81%) and the Modular P (86%). Bicarbonate and magnesium were not transferable on either system and calcium and prealbumin were not transferable to the Modular P. Of the transferable analytes, 62% and 61% were verified on the cobas 6000 and the Modular P, respectively. This study extends the utility of the CALIPER database to two additional analytical systems, which facilitates the broad application of CALIPER reference intervals at pediatric centers utilizing Roche biochemical assays. Transference studies across different analytical platforms can later be collectively analyzed in an attempt to develop common reference intervals across all clinical chemistry instruments to harmonize laboratory test interpretation in diagnosis and monitoring of pediatric disease. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Diagnosis of hyperthyroidism in cats with mild chronic kidney disease.

    PubMed

    Wakeling, J; Moore, K; Elliott, J; Syme, H

    2008-06-01

    In cats with concurrent hyperthyroidism and non-thyroidal illnesses such as chronic kidney disease, total thyroxine concentrations are often within the laboratory reference range (19 to 55 nmol/l). The objective of the study was to determine total thyroxine, free thyroxine and/or thyroid-stimulating hormone concentrations in cats with mild chronic kidney disease. Total thyroxine, free thyroxine and thyroid-stimulating hormone were measured in three groups. The hyperthyroidism-chronic kidney disease group (n=16) had chronic kidney disease and clinical signs compatible with hyperthyroidism but a plasma total thyroxine concentration within the reference range. These cats were subsequently confirmed to be hyperthyroid at a later date. The chronic kidney disease-only group (n=20) had chronic kidney disease but no signs of hyperthyroidism. The normal group (n=20) comprised clinically healthy senior (>8 years) cats. In 4 of 20 euthyroid chronic kidney disease cats, free thyroxine concentrations were borderline or high (> or =40 pmol/l). In the hyperthyroidism-chronic kidney disease group, free thyroxine was high in 15 of 16 cats, while thyroid-stimulating hormone was low in 16 of 16 cats. Most hyperthyroidism-chronic kidney disease cats (14 of 16) had total thyroxine greater than 30 nmol/l, whereas all the chronic kidney disease-only cats had total thyroxine less than 30 nmol/l. The combined measurement of free thyroxine with total thyroxine or thyroid-stimulating hormone may be of merit in the diagnosis of hyperthyroidism in cats with chronic kidney disease.

  12. Clinical Characteristic of the HIV/AIDS Patients with Cryptosporidiosis Referring to Behavioral Diseases Consultation Center, Imam Khomeini Hospital, Tehran in 2013.

    PubMed

    Gholami, Rashid; Gholami, Shirzad; Emadi-Kouchak, Hamid; Abdollahi, Alireza; Shahriari, Mona

    2016-01-01

    Cryptosporidium is known as an opportunist disease-causing agent in man in recent decades. It causes diarrhea and intestinal disorders in the immune deficit and immune competent individuals. This study was aimed to investigate the clinical characteristics of HIV/AIDS patients with cryptosporidiosis infection. This cross-sectional descriptive study was performed on 53 HIV/AIDS patients referred to the Behavior Disease Consultation Center of Imam Khomeini Hospital in Tehran, Iran in 2013. First, the patients were studied clinically and the context data were recorded in a questionnaire for parasitological examination and referred to the laboratory for eosinophil count, and CD4 count per ml of blood. Cryptosporidiosis was observed in 4 (7.6%) of the total 53 HIV/AIDS patients. The highest prevalence of infection was observed in the age range of 30-39 yr. It was observed in different sexes as 5.7% of male and 1.9% of female, but statistically was insignificant (P=0.163).75% of patients had no intestinal symptom, 11.4% with acute diarrhea and 3.8% with chronic diarrhea. Cryptosporidiosis cases were observed in 5.7% of patients without intestinal symptom. Practitioners in the clinical examination for the detection of the opportunistic intestinal protozoan infection should use clinical and paraclinical characteristics of the HIV/AIDS patients for the diagnostic of Cryptosporidium and other opportunistic parasitic diseases.

  13. [Real-time PCR detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae DNA in clinical specimens].

    PubMed

    Vacková, Z; Lžičařová, D; Stock, N K; Kozáková, J

    2015-10-01

    The study aim was to implement a molecular real-time polymerase chain reaction (PCR) assay recommended by the CDC (Centers for Disease Control and Prevention) for the detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae in clinical (culture negative) specimens from patients with suspected invasive bacterial disease. Clinical specimens are referred to the National Reference Laboratory (NRL) for Meningococcal Infections, Unit for Airborne Bacterial Infections, Centre for Epidemiology and Microbiology, National Institute of Public Health from various regions of the Czech Republic. Clinical specimens are, in particular, cerebrospinal fluid, anti-coagulated blood or serum and, exceptionally, post-mortem specimens. The NRL has implemented molecular diagnosis of these bacterial pathogens involved in meningitis and sepsis from clinical specimens since 1999. The first diagnostic method was semi-nested PCR followed by electrophoretic analysis. In 2014, a molecular qualitative real-time PCR assay was implemented.

  14. Differences in levels of albumin, ALT, AST, γ-GT and creatinine in frail, moderately healthy and healthy elderly individuals.

    PubMed

    Edvardsson, Maria; Sund-Levander, Märtha; Milberg, Anna; Wressle, Ewa; Marcusson, Jan; Grodzinsky, Ewa

    2018-02-23

    Reference intervals are widely used as decision tools, providing the physician with information about whether the analyte values indicate ongoing disease process. Reference intervals are generally based on individuals without diagnosed diseases or use of medication, which often excludes elderly. The aim of the study was to assess levels of albumin, alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine and γ-glutamyl transferase (γ-GT) in frail, moderately healthy and healthy elderly indivuduals. Blood samples were collected from individuals >80 years old, nursing home residents, in the Elderly in Linköping Screening Assessment and Nordic Reference Interval Project, a total of 569 individuals. They were divided into three cohorts: frail, moderately healthy and healthy, depending on cognitive and physical function. Albumin, ALT, AST, creatinine and γ-GT were analyzed using routine methods. Linear regression predicted factors for 34% of the variance in albumin were activities of daily living (ADL), gender, stroke and cancer. ADLs, gender and weight explained 15% of changes in ALT. For AST levels, ADLs, cancer and analgesics explained 5% of changes. Kidney disease, gender, Mini Mental State Examination (MMSE) and chronic obstructive pulmonary disease explained 25% of the variation in creatinine levels and MMSE explained three per cent of γ-GT variation. Because a group of people are at the same age, they should not be assessed the same way. To interpret results of laboratory tests in elderly is a complex task, where reference intervals are one part, but far from the only one, to take into consideration.

  15. The value of the Thomas-plot in the diagnostic work up of anemic patients referred by general practitioners.

    PubMed

    Leers, M P G; Keuren, J F W; Oosterhuis, W P

    2010-12-01

    In patients with inflammatory conditions, diagnosing classic iron deficiency or anemia of chronic disease is challenging. In this study, we assessed the diagnostic value of the so-called Thomas'-plot [soluble transferrin receptor (sTfR)/log ferritin (sTfr/log Ferr) and the reticulocyte hemoglobin equivalent (Ret-HE)] in the anemia work up of patients referred by general practitioners. During July 2008-March 2009, 337 consecutive patients were included because of lowered Hb values. The laboratory results of the first 133 consecutive patients were used to determine the cut-off values for the diagnostic plot. The laboratory results of these patients were assessed and interpreted independently by two investigators, blinded from sTfR/log Ferr and Ret-HE values. The following 204 patients were used to test the plot in practice. In 32% of the first 133 patients, no indication of the cause of anemia could be found. However, when using the diagnostic plot in the following 204 patients, this fraction decreased to 14%. The 'Thomas'-plot is of diagnostic value for distinguishing functional iron deficiency from classic iron deficiency in a patient population referred by general practitioners. © 2010 Blackwell Publishing Ltd.

  16. Validity of diagnoses, procedures, and laboratory data in Japanese administrative data.

    PubMed

    Yamana, Hayato; Moriwaki, Mutsuko; Horiguchi, Hiromasa; Kodan, Mariko; Fushimi, Kiyohide; Yasunaga, Hideo

    2017-10-01

    Validation of recorded data is a prerequisite for studies that utilize administrative databases. The present study evaluated the validity of diagnoses and procedure records in the Japanese Diagnosis Procedure Combination (DPC) data, along with laboratory test results in the newly-introduced Standardized Structured Medical Record Information Exchange (SS-MIX) data. Between November 2015 and February 2016, we conducted chart reviews of 315 patients hospitalized between April 2014 and March 2015 in four middle-sized acute-care hospitals in Shizuoka, Kochi, Fukuoka, and Saga Prefectures and used them as reference standards. The sensitivity and specificity of DPC data in identifying 16 diseases and 10 common procedures were identified. The accuracy of SS-MIX data for 13 laboratory test results was also examined. The specificity of diagnoses in the DPC data exceeded 96%, while the sensitivity was below 50% for seven diseases and variable across diseases. When limited to primary diagnoses, the sensitivity and specificity were 78.9% and 93.2%, respectively. The sensitivity of procedure records exceeded 90% for six procedures, and the specificity exceeded 90% for nine procedures. Agreement between the SS-MIX data and the chart reviews was above 95% for all 13 items. The validity of diagnoses and procedure records in the DPC data and laboratory results in the SS-MIX data was high in general, supporting their use in future studies. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  17. [Imported diseases, the epidemiological challenge of communicable diseases (author's transl)].

    PubMed

    Gsell, O

    1978-06-01

    Imported infectious diseases being seen more often in consequence of intensive human contacts with developing countries through labourers and tourists, but also in consequence of immigration and of import of exotic diseases and of food, favoured by the quick air traffic, can be divided into 5 groups: 1. Imported diseases from the tropics (exotic diseases) 2. Imported agents from the tropics with human infection in the native country 3. Re-importation of diseases which were eliminated in the homelands 4. Diseases which are as well imported as also native 5. Single disease importations from neighboured countries. The imported infections are discussed systematically, caused by viruses, rickettsias, bacteries, protozoes, fungi, and followed by references to statistics, laboratory infection reports, questions of insurance. Imported diseases of the future are especially mentioned. Knowledge of the tropical infections as a main danger for our "civilized" world should be part of the medical training, since imported infectious diseases cause an epidemiologic challenge in the modern picture of communicable infections.

  18. Responses to a questionnaire on networking between OIE Reference Laboratories and OIE Collaborating Centres.

    PubMed

    Brückner, G K; Linnane, S; Diaz, F; Vallat, B

    2007-01-01

    Two separate questionnaires were distributed to 20 OIE Collaborating Centres and 160 OIE Reference Laboratories to assess the current status of networking and collaboration among OIE Reference Laboratories and between OIE Reference Laboratories and OIE Collaborating Centres. The questionnaire for the OIE Reference Laboratories contained 7 sections with questions on networking between laboratories, reporting of information, biosecurity quality control, and financing. Emphasis was placed in obtaining information on inter-laboratory relationships and exchange of expertise, training needs and sharing of data and information. The questionnaire for the OIE Collaborating Centres contained six sections with the emphasis on aspects related to awareness of services that can be provided, expertise that could be made available, sharing of information and the relationship with the national veterinary services of the countries concerned. The responses to the questionnaires were collated, categorised and statistically evaluated to allow for tentative inferences on the data provided. Valuable information emanated from the data identifying the current status of networking and indicating possible shortcomings that could be addressed to improve networking.

  19. The Qatar genome project: translation of whole-genome sequencing into clinical practice.

    PubMed

    Zayed, Hatem

    2016-10-01

    Qatar Genome Project was launched in 2013 with the intent to sequence the genome of each Qatari citizen in an effort to protect Qataris from the high rate of indigenous genetic diseases by allowing the mapping of disease-causing variants/rare variants and establishing a Qatari reference genome. Indeed, this project is expected to have numerous global benefits because the elevated homogeneity of the Qatari population, that will make Qatar an excellent genetic laboratory that will generate a wealth of data that will allow us to make sense of the genotype-phenotype correlations of many diseases, especially the complex multifactorial diseases, and will pave the way for changing the traditional medical practice of looking first at the phenotype rather than the genotype. © 2016 John Wiley & Sons Ltd.

  20. Evaluation of a multiplex PCR to identify and serotype Actinobacillus pleuropneumoniae serovars 1, 5, 7, 12 and 15.

    PubMed

    Turni, C; Singh, R; Schembri, M A; Blackall, P J

    2014-10-01

    The aim of this study was to validate a multiplex PCR for the species identification and serotyping of Actinobacillus pleuropneumoniae serovars 1, 5, 7, 12 and 15. All 15 reference strains and 411 field isolates (394 from Australia, 11 from Indonesia, five from Mexico and one from New Zealand) of A. pleuropneumoniae were tested with the multiplex PCR. The specificity of this multiplex PCR was validated on 26 non-A. pleuropneumoniae species. The multiplex PCR gave the expected results with all 15 serovar reference strains and agreed with conventional serotyping for all field isolates from serovars 1 (n = 46), 5 (n = 81), 7 (n = 80), 12 (n = 16) and serovar 15 (n = 117). In addition, a species-specific product was amplified in the multiplex PCR with all 411 A. pleuropneumoniae field isolates. Of 25 nontypeable field isolates only two did not yield a serovar-specific band in the multiplex PCR. This multiplex PCR for serovars 1, 5, 7, 12 and 15 is species specific and capable of serotyping isolates from diverse locations. Significance and impact of the study: A multiplex PCR that can recognize serovars 1, 5, 7, 12 and 15 of A. pleuropneumoniae was developed and validated. This novel diagnostic tool will enable frontline laboratories to provide key information (the serovar) to guide targeted prevention and control programmes for porcine pleuropneumonia, a serious economic disease of pigs. The previous technology, traditional serotyping, is typically provided by specialized reference laboratories, limiting the capacity to respond to this key disease. © 2014 The Society for Applied Microbiology.

  1. Recommendation for the review of biological reference intervals in medical laboratories.

    PubMed

    Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel

    2016-12-01

    This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.

  2. Reference values for 27 clinical chemistry tests in 70-year-old males and females.

    PubMed

    Carlsson, Lena; Lind, Lars; Larsson, Anders

    2010-01-01

    Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.

  3. Make versus buy: a financial perspective.

    PubMed

    Kisner, Harold J

    2003-01-01

    Clinical laboratories are often faced with the decision to either perform a service in-house using their own assets or outsource the service to another vendor. This decision affects many aspects of the laboratory's business, from the macroeconomic perspective of outsourcing the laboratory service to a laboratory vendor, to the microeconomics of determining whether to refer a test out to their reference laboratory or perform the test in-house. The basis for decision making includes many variables, but a detailed financial analysis is usually the basis for the decision, especially when the decision only affects the laboratory and not the rest of the institution. Other factors often come into play, and depending on the magnitude, the "make versus buy" decision could be based more on strategic or political factors than economics. Even when noneconomic factors are involved, an effort usually is made to quantify those factors so that the make versus buy decision is reduced to financial terms. The previous article in this issue, "Effectively Managing Your Reference Laboratory Relationship" by Ronald L. Weiss, M.D., focused on the "buy" decision relating to managing the reference laboratory relationship. Although that article took a more clinical perspective through the eyes of the reference laboratory, this article looks at the make versus buy decision from a financial perspective through the eyes of the buying party.

  4. EMQN/CMGS best practice guidelines for the molecular genetic testing of Huntington disease.

    PubMed

    Losekoot, Monique; van Belzen, Martine J; Seneca, Sara; Bauer, Peter; Stenhouse, Susan A R; Barton, David E

    2013-05-01

    Huntington disease (HD) is caused by the expansion of an unstable polymorphic trinucleotide (CAG)n repeat in exon 1 of the HTT gene, which translates into an extended polyglutamine tract in the protein. Laboratory diagnosis of HD involves estimation of the number of CAG repeats. Molecular genetic testing for HD is offered in a wide range of laboratories both within and outside the European community. In order to measure the quality and raise the standard of molecular genetic testing in these laboratories, the European Molecular Genetics Quality Network has organized a yearly external quality assessment (EQA) scheme for molecular genetic testing of HD for over 10 years. EQA compares a laboratory's output with a fixed standard both for genotyping and reporting of the results to the referring physicians. In general, the standard of genotyping is very high but the clarity of interpretation and reporting of the test result varies more widely. This emphasizes the need for best practice guidelines for this disorder. We have therefore developed these best practice guidelines for genetic testing for HD to assist in testing and reporting of results. The analytical methods and the potential pitfalls of molecular genetic testing are highlighted and the implications of the different test outcomes for the consultand and his or her family members are discussed.

  5. Can we Predict Disease Course with Clinical Factors?

    PubMed

    Vegh, Zsuzsanna; Kurti, Zsuzsanna; Golovics, Petra A; Lakatos, Peter L

    2018-01-01

    The disease phenotype at diagnosis and the disease course of Crohn's disease (CD) and ulcerative colitis (UC) show remarkable heterogeneity across patients. This review aims to summarize the currently available evidence on clinical and some environmental predictive factors, which clinicians should evaluate in the everyday practice together with other laboratory and imaging data to prevent disease progression, enable a more personalized therapy, and avoid negative disease outcomes. In recent population-based epidemiological and referral cohort studies, the evolution of disease phenotype of CD and UC varied significantly. Most CD and severe UC patients still require hospitalization or surgery/colectomy during follow-up. A change in the natural history of inflammatory bowel diseases (IBD) with improved outcomes in parallel with tailored positioning of aggressive immunomodulator and biological therapy has been suspected. According to the currently available literature, it is of major importance to refer IBD cases at risk for adverse disease outcomes as early during the disease course as possible. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    PubMed

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  7. Changes in serotype distribution of Haemophilus influenzae meningitis isolates identified through laboratory-based surveillance following routine childhood vaccination against H. influenzae type b in Brazil.

    PubMed

    Zanella, Rosemeire C; Bokermann, Sérgio; Andrade, Ana Lúcia S S; Flannery, Brendan; Brandileone, Maria Cristina de C

    2011-11-08

    Following routine childhood vaccination against Haemophilus influenzae type b (Hib) disease in Brazil in 1999, passive laboratory surveillance reported increasing numbers of non-b serotypes and nontypeable H. influenzae (NTHi) from meningitis cases. To characterize this increase, we analyzed data on 3910 H. influenzae isolated from cerebrospinal fluid or blood from meningitis cases that were sent to the national reference laboratory for serotyping from 1990 to 2008. Hib accounted for 98% of H. influenzae meningitis isolates received during 1990-1999 versus 59% during 2000-2008, while non-b serotypes increased from 1% to 19% and NTHi increased from 2% to 22% of H. influenzae isolates received during the two periods. Higher proportions of non-b serotypes and NTHi than Hib were isolated from blood rather than cerebrospinal fluid. Estimated incidence rates for H. influenzae meningitis for Sao Paulo state remained below 1 case per million population during 2000-2008, although annual incidence of NTHi meningitis (mean, 0.03 cases per 100,000 population) increased in several age groups. Changes in surveillance for H. influenzae following introduction of Hib conjugate vaccine likely contributed to increased numbers of non-b and nontypeable H. influenzae meningitis isolates received at the national reference laboratory. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes

    PubMed Central

    Pratt, Victoria M.; Everts, Robin E.; Aggarwal, Praful; Beyer, Brittany N.; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A.; Smith, Chingying Huang; Toji, Lorraine H.; Turner, Amy; Kalman, Lisa V.

    2017-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention–based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. PMID:26621101

  9. Prevalence of vitamin D deficiency and rickets in children with cholestasis in Iran.

    PubMed

    Mohammadi, Bahram; Najafi, Mehri; Farahmand, Fateme; Motamed, Farzaneh; Ghajarzadeh, Mahsa; Mohammadi, Jamshid; Eshagh Roze, Mohammad

    2012-01-01

    This study was aimed to determine prevalence of vitamin D deficiency and rickets in children with cholestatic liver diseases. Forty eight children with established cholestatic liver disease who referred to gastrointestinal clinic of Children Medical Center (Tehran, Iran) between April 2010 and March 2011 were enrolled in a cross-sectional study. Laboratory analysis including calcium, phosphate, albumin, total and direct bilirubin, aminotransferases, alkalinephosphatase (ALP), prothrombin time (PT), parathyroid hormone (PTH), total protein determined by routine laboratory techniques. Mean age of participants was 299.1 ± 676.8 days (range 2-3600 days) whereas twenty one were female (43.8%) and 27 (56.3%) were male. Twenty two (45.8%) had evidences of rickets in X-ray evaluation. Three children with rickets and two with normal X-ray had vitamin D deficiency while ten in rickets group and 16 in normal group had vitamin D insufficiency. The main underlying diseases were anatomical biliary atresia in cases with rickets and idiopathic in other group. Rickets and vitamin D deficiency should be considered in chronic cholestatic children.

  10. Uptake of recommended common reference intervals for chemical pathology in Australia.

    PubMed

    Jones, Graham Rd; Koetsier, Sabrina

    2017-05-01

    Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.

  11. Pediatric reference intervals for alkaline phosphatase.

    PubMed

    Zierk, Jakob; Arzideh, Farhad; Haeckel, Rainer; Cario, Holger; Frühwald, Michael C; Groß, Hans-Jürgen; Gscheidmeier, Thomas; Hoffmann, Reinhard; Krebs, Alexander; Lichtinghagen, Ralf; Neumann, Michael; Ruf, Hans-Georg; Steigerwald, Udo; Streichert, Thomas; Rascher, Wolfgang; Metzler, Markus; Rauh, Manfred

    2017-01-01

    Interpretation of alkaline phosphatase activity in children is challenging due to extensive changes with growth and puberty leading to distinct sex- and age-specific dynamics. Continuous percentile charts from birth to adulthood allow accurate consideration of these dynamics and seem reasonable for an analyte as closely linked to growth as alkaline phosphatase. However, the ethical and practical challenges unique to pediatric reference intervals have restricted the creation of such percentile charts, resulting in limitations when clinical decisions are based on alkaline phosphatase activity. We applied an indirect method to generate percentile charts for alkaline phosphatase activity using clinical laboratory data collected during the clinical care of patients. A total of 361,405 samples from 124,440 patients from six German tertiary care centers and one German laboratory service provider measured between January 2004 and June 2015 were analyzed. Measurement of alkaline phosphatase activity was performed on Roche Cobas analyzers using the IFCC's photometric method. We created percentile charts for alkaline phosphatase activity in girls and boys from birth to 18 years which can be used as reference intervals. Additionally, data tables of age- and sex-specific percentile values allow the incorporation of these results into laboratory information systems. The percentile charts provided enable the appropriate differential diagnosis of changes in alkaline phosphatase activity due to disease and changes due to physiological development. After local validation, integration of the provided percentile charts into result reporting facilitates precise assessment of alkaline phosphatase dynamics in pediatrics.

  12. Operational Art and the Incident Command System: Public Health’s Bridge in Bioterrorism Preparedness and Response

    DTIC Science & Technology

    2003-03-22

    e.g., tuberculosis screening or a maximal treadmill test ); and 3) tertiary prevention limits disability and rehabilitation where the disease or injury...major city/county laboratories to develop the capacity to conduct rapid and accurate diagnostic and reference testing for select biologic agents likely...system, but it has not been thoroughly tested and coordinated in the civilian sector. The association of mass casualty care with hospital

  13. Association of Reference Pricing for Diagnostic Laboratory Testing With Changes in Patient Choices, Prices, and Total Spending for Diagnostic Tests.

    PubMed

    Robinson, James C; Whaley, Christopher; Brown, Timothy T

    2016-09-01

    Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with access to price information, reference pricing was associated with patient choice of lower-cost laboratories and reductions in prices and payments by both employer and employees.

  14. Serological Diagnosis of Paracoccidioidomycosis: High Rate of Inter-laboratorial Variability among Medical Mycology Reference Centers

    PubMed Central

    Vidal, Monica Scarpelli Martinelli; Del Negro, Gilda Maria Barbaro; Vicentini, Adriana Pardini; Svidzinski, Teresinha Inez Estivalet; Mendes-Giannini, Maria Jose; Almeida, Ana Marisa Fusco; Martinez, Roberto; de Camargo, Zoilo Pires; Taborda, Carlos Pelleschi; Benard, Gil

    2014-01-01

    Background Serological tests have long been established as rapid, simple and inexpensive tools for the diagnosis and follow-up of PCM. However, different protocols and antigen preparations are used and the few attempts to standardize the routine serological methods have not succeeded. Methodology/Principal findings We compared the performance of six Brazilian reference centers for serological diagnosis of PCM. Each center provided 30 sera of PCM patients, with positive high, intermediate and low titers, which were defined as the “reference” titers. Each center then applied its own antigen preparation and serological routine test, either semiquantitative double immunodifusion or counterimmmunoelectrophoresis, in the 150 sera from the other five centers blindly as regard to the “reference” titers. Titers were transformed into scores: 0 (negative), 1 (healing titers), 2 (active disease, low titers) and 3 (active disease, high titers) according to each center's criteria. Major discordances were considered between scores indicating active disease and scores indicating negative or healing titers; such discordance when associated with proper clinical and other laboratorial data, may correspond to different approaches to the patient's treatment. Surprisingly, all centers exhibited a high rate of “major” discordances with a mean of 31 (20%) discordant scores. Alternatively, when the scores given by one center to their own sera were compared with the scores given to their sera by the remaining five other centers, a high rate of major discordances was also found, with a mean number of 14.8 sera in 30 presenting a discordance with at least one other center. The data also suggest that centers that used CIE and pool of isolates for antigen preparation performed better. Conclusion There are inconsistencies among the laboratories that are strong enough to result in conflicting information regarding the patients' treatment. Renewed efforts should be promoted to improve standardization of the serological diagnosis of PCM. PMID:25211336

  15. Mortality among British Columbians testing for hepatitis C antibody.

    PubMed

    Yu, Amanda; Spinelli, John J; Cook, Darrel A; Buxton, Jane A; Krajden, Mel

    2013-04-02

    Hepatitis C virus (HCV) infection is a major preventable and treatable cause of morbidity and mortality. The ability to link population based centralized laboratory HCV testing data with administrative databases provided a unique opportunity to compare mortality between HCV seronegative and seropositive individuals. Through the use of laboratory testing patterns and results, the objective of this study was to differentiate the viral effects of mortality due to HCV infection from risk behaviours/activities that are associated with acquisition of HCV infection. Serological testing data from the British Columbia (BC) Centre for Disease Control Public Health Microbiology and Reference Laboratory from 1992-2004 were linked to the BC Vital Statistics Agency death registry. Four groups of HCV testers were defined by their HCV antibody (anti-HCV) testing patterns: single non-reactive (SNR); serial multiple tested non-reactive (MNR); reactive at initial testing (REAC); and seroconverter (SERO) (previously seronegative followed by reactive, a marker for incident infection). Standardized mortality ratios (SMRs) were calculated to compare the relative risk of all cause and disease specific mortality to that of the BC population for each serological group. Time dependent Cox proportional hazard regression was used to compare hazard ratios (HRs) among HCV serological groups. All anti-HCV testers had higher SMRs than the BC population. Referent to the SNR group, the REAC group had higher risks for liver (HR: 9.62; 95% CI=8.55-10.87) and drug related mortality (HR: 13.70; 95% CI=11.76-16.13). Compared to the REAC group, the SERO group had a lower risk for liver (HR: 0.53; 95% CI=0.24-0.99), but a higher risk for drug related mortality (HR: 1.54; 95% CI=1.12-2.05). These findings confirm that individuals who test anti-HCV positive have increased mortality related to progressive liver disease, and that a substantial proportion of the mortality is attributable to drug use and risk behaviours/activities associated with HCV acquisition. Mortality reduction in HCV infected individuals will require comprehensive prevention programming to reduce the harms due to behaviours/activities which relate to HCV acquisition, as well as HCV treatment to prevent progression of chronic liver disease.

  16. Population-based pediatric reference intervals for general clinical chemistry analytes on the Abbott Architect ci8200 instrument.

    PubMed

    Ridefelt, Peter; Aldrimer, Mattias; Rödöö, Per-Olof; Niklasson, Frank; Jansson, Leif; Gustafsson, Jan; Hellberg, Dan

    2012-02-29

    Reference intervals are crucial decision-making tools aiding clinicians in differentiating between healthy and diseased populations. However, for children such values often are lacking or incomplete. Blood samples were obtained from 692 healthy children, aged 6 months to 18 years, recruited in daycare centers and schools. Twelve common general clinical chemistry analytes were measured on the Abbott Architect ci8200 platform; sodium, potassium, chloride, calcium, albumin-adjusted calcium, phosphate, magnesium, creatinine (Jaffe and enzymatic), cystatin C, urea and uric acid. Age- and gender specific pediatric reference intervals were defined by calculating the 2.5th and 97.5th percentiles. The data generated is primarily applicable to a Caucasian population when using the Abbott Architect platform, but could be used by any laboratory if validated for the local patient population.

  17. U.S. Geological Survey Standard Reference Sample Project: Performance Evaluation of Analytical Laboratories

    USGS Publications Warehouse

    Long, H. Keith; Daddow, Richard L.; Farrar, Jerry W.

    1998-01-01

    Since 1962, the U.S. Geological Survey (USGS) has operated the Standard Reference Sample Project to evaluate the performance of USGS, cooperator, and contractor analytical laboratories that analyze chemical constituents of environmental samples. The laboratories are evaluated by using performance evaluation samples, called Standard Reference Samples (SRSs). SRSs are submitted to laboratories semi-annually for round-robin laboratory performance comparison purposes. Currently, approximately 100 laboratories are evaluated for their analytical performance on six SRSs for inorganic and nutrient constituents. As part of the SRS Project, a surplus of homogeneous, stable SRSs is maintained for purchase by USGS offices and participating laboratories for use in continuing quality-assurance and quality-control activities. Statistical evaluation of the laboratories results provides information to compare the analytical performance of the laboratories and to determine possible analytical deficiences and problems. SRS results also provide information on the bias and variability of different analytical methods used in the SRS analyses.

  18. [On the way to national reference system of laboratory medicine].

    PubMed

    Muravskaia, N P; Men'shikov, V V

    2014-10-01

    The application of standard samples and reference techniques of implementation of measurements is needed for a valid support of reliability of analyses applied in clinical diagnostic laboratories. They play role of landmarks under metrologic monitoring, calibration of devices and control of quality of results. The article presents analysis of shortcomings interfering with formation of national reference system in Russia harmonized with possibilities provided by international organizations. Among them are the joint Committee on metrologic monitoring in laboratory medicine under the auspices of the International Bureau of Weights and Measures, the International Federation of clinical chemistry and laboratory medicine, etc. The results of the recent development of national normative documents, standard samples and techniques assisted by the authors of article are considered. They are the first steps to organization of national reference system which would comprise all range of modern analytical technologies of laboratory medicine. The national and international measures are proposed to enhance the promptest resolving of task of organization of national reference system for laboratory medicine in the interests of increasing of effectiveness of medical care to citizen of Russia.

  19. Molecular diagnosis of α-thalassemia in a multiethnic population.

    PubMed

    Gilad, Oded; Shemer, Orna Steinberg; Dgany, Orly; Krasnov, Tanya; Nevo, Michal; Noy-Lotan, Sharon; Rabinowicz, Ron; Amitai, Nofar; Ben-Dor, Shifra; Yaniv, Isaac; Yacobovich, Joanne; Tamary, Hannah

    2017-06-01

    α-Thalassemia, one of the most common genetic diseases, is caused by deletions or point mutations affecting one to four α-globin genes. Molecular diagnosis is important to prevent the most severe forms of the disease. However, the diagnosis of α-thalassemia is complex due to a high variability of the genetic defects involved, with over 250 described mutations. We summarize herein the findings of genetic analyses of DNA samples referred to our laboratory for the molecular diagnosis of α-thalassemia, along with a detailed clinical description. We utilized a diagnostic algorithm including Gap-PCR, to detect known deletions, followed by sequencing of the α-globin gene, to identify known and novel point mutations, and multiplex ligation-dependent probe amplification (MLPA) for the diagnosis of rare or novel deletions. α-Thalassemia was diagnosed in 662 of 975 samples referred to our laboratory. Most commonly found were deletions (75.3%, including two novel deletions previously described by us); point mutations comprised 25.4% of the cases, including five novel mutations. Our population included mostly Jews (of Ashkenazi and Sephardic origin) and Muslim Arabs, who presented with a higher rate of point mutations and hemoglobin H disease. Overall, we detected 53 different genotype combinations causing a spectrum of clinical phenotypes, from asymptomatic to severe anemia. Our work constitutes the largest group of patients with α-thalassemia originating in the Mediterranean whose clinical characteristics and molecular basis have been determined. We suggest a diagnostic algorithm that leads to an accurate molecular diagnosis in multiethnic populations. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Development of an evidence-based approach to external quality assurance for breast cancer hormone receptor immunohistochemistry: comparison of reference values.

    PubMed

    Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E

    2011-07-01

    External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.

  1. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil.

    PubMed

    Wludarski, Sheila Cristina Lordelo; Lopes, Lisandro Ferreira; Duarte, Ivison Xavier; Carvalho, Filomena Marino; Weiss, Lawrence; Bacchi, Carlos Eduardo

    2011-01-01

    Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community) laboratories in Brazil. Retrospective study at a reference pathology laboratory. The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. There was concordance in 89.4% (447/500 cases) and 85.0% (425/500 cases) of the results from estrogen (κ = 0.744, P < 0.001) and progesterone (κ = 0.688, P < 0.001) receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  2. Laboratory Measurement Implications of Decreasing Childhood Blood Lead Levels

    PubMed Central

    Caldwell, Kathleen L.; Cheng, Po-Yung; Jarrett, Jeffery M.; Makhmudov, Amir; Vance, Kathryn; Ward, Cynthia D.; Jones, Robert L.; Mortensen, Mary E.

    2017-01-01

    In 2012, the Centers for Disease Control and Prevention (CDC) adopted its Advisory Committee on Childhood Lead Poisoning Prevention (ACCLPP) recommendation to use a population-based reference value to identify children and environments associated with lead hazards. The current reference value of 5 μg/dL is calculated as the 97.5th percentile of the distribution of blood lead levels (BLL) in children one to five years old from 2007–2010 National Health and Nutrition Examination Survey (NHANES) data. We calculated and updated selected percentiles, including the 97.5th percentile, using NHANES 2011–2014 blood lead data and examined demographic characteristics of children whose blood lead was ≥90th percentile value. The 97.5% percentile BLL of 3.48 μg/dL highlighted analytical laboratory and clinical interpretation challenges of blood lead measurements ≤ 5 μg/dL. Review of five years of results for target blood lead values < 11 μg/dL for U.S. clinical laboratories participating in CDC’s voluntary Lead and Multi-Element Proficiency (LAMP) quality assurance program showed 40% unable to quantify and reported a non-detectable result at a target blood lead value of 1.48 μg/dL compared 5.5 % at a target blood lead of 4.60 μg/dL. We describe actions taken at CDC’s Environmental Health Laboratory in the Division of Laboratory Sciences, which measures blood lead for NHANES, to improve analytical accuracy and precision and to reduce external lead contamination during blood collection and analysis. PMID:28771411

  3. Nanomedicine: Promising Tiny Machine for the Healthcare in Future-A Review

    PubMed Central

    Saha, Moni

    2009-01-01

    One of the 21st century’s most promising technologies is nanotechnology. Nanomedicine, an offshoot of nanotechnology, refers to highly specific medical intervention at the molecular scale for curing disease or repairing damaged tissues, such as bone, muscle, or nerve. Nanotechnology is a collective term referring to technological developments on the nanometer scale, usually 0.1-100 nm. A nanometer is one-billionth of a meter, too small to be seen with a conventional laboratory microscope. It is at this size scale - about 100 nanometers or less - that biological molecules and structures inside living cells operate. Therefore, nanotechnology is engineering and manufacturing at the molecular scale. Utilities of nanotechnology to biomedical sciences imply creation of materials and devices designed to interact with the body at sub-cellular scales with a high degree of specificity. This could be potentially translated into targeted cellular and tissue-specific clinical applications aimed at maximal therapeutic effects with very limited adverse-effects. Nanomedicine can offer impressive resolutions for various life threatening diseases. Disease areas which can be expected to benefit most from nanotechnology within the next few years are cancer, diseases of the cardiovascular system, the lungs, blood, neurological (especially neurodegenerative) diseases, diabetes, inflammatory/infectious diseases, Parkinson’s or Alzheimer’s disease and orthopaedic problems. In the first half of the 21st century, nanomedicine should eliminate virtually all common diseases of the 20th century, and virtually all medical pain. This article presents an overview of some of the applications of nanotechnology in nanomedicine. PMID:22216376

  4. Recommendations for Management of Endemic Diseases and Travel Medicine in Solid-Organ Transplant Recipients and Donors: Latin America.

    PubMed

    Clemente, Wanessa Trindade; Pierrotti, Lígia Camera; Abdala, Edson; Morris, Michele I; Azevedo, Luiz S; López-Vélez, Rogelio; Cuenca-Estrella, Manuel; Torre-Cisneros, Julian; Petersen, Eskild; Camargo, Luis Fernando A; Wright, Alissa Jade; Beeching, Nicholas J; Vilela, Eduardo Garcia; Santoro-Lopes, Guilherme; Len, Oscar; Stucchi, Raquel S B; Manuel, Oriol; Faria, Luciana Costa; Leblebicioglu, Hakan; Huprikar, Shirish; Molina, Israel; Mourão, Paulo Henrique Orlandi; Kotton, Camille N; Aguado, José María

    2018-02-01

    The Recommendations for Management of Endemic Diseases and Travel Medicine in Solid-Organ Transplant Recipients and Donors: Latin America clinical practice guideline is intended to guide clinicians caring for solid-organ transplant (SOT) donors, candidates and recipients regarding infectious diseases (ID) issues related to this geographical region, mostly located in the tropics. These recommendations are based on both systematic reviews of relevant literature and expert opinion from both transplant ID and travel medicine specialists. The guidelines provide recommendations for risk evaluation and laboratory investigation, as well as management and prevention of infection of the most relevant endemic diseases of Latin America. This summary includes a brief description of the guideline recommendations but does not include the complete rationale and references for each recommendation, which is available in the online version of the article, published in this journal as a supplement. The supplement contains 10 reviews referring to endemic or travel diseases (eg, tuberculosis, Chagas disease [ChD], leishmaniasis, malaria, strongyloidiasis and schistosomiasis, travelers diarrhea, arboviruses, endemic fungal infections, viral hepatitis, and vaccines) and an illustrative section with maps (http://www.pmourao.com/map/). Contributors included experts from 13 countries (Brazil, Canada, Chile, Denmark, France, Italy, Peru, Spain, Switzerland, Turkey, United Kingdom, United States, and Uruguay) representing four continents (Asia, the Americas and Europe), along with scientific and medical societies.

  5. Cholera in the time of war: implications of weak surveillance in Syria for the WHO's preparedness—a comparison of two monitoring systems

    PubMed Central

    Sparrow, Annie; Almilaji, Khaled; Tajaldin, Bachir; Teodoro, Nicholas; Langton, Paul

    2016-01-01

    Background Public health breakdown from the Syrian government's targeting of healthcare systems in politically unsympathetic areas has yielded a resurgence of infectious diseases. Suspected cholera recently reappeared but conflict-related constraints impede laboratory confirmation. Given the government's previous under-reporting of infectious outbreaks and the reliance of the WHO on government reporting, we sought to assess the reliability of current surveillance systems. Methods We compared weekly surveillance reports of waterborne diseases from the Syrian government's (WHO-associated) Early Warning and Response System (EWARS), based in Damascus, and the independent, non-governmental Early Warning and Response Network (EWARN) headquartered in Gaziantep, Turkey. We compared raw case rates by EWARS and EWARN and assessed the quality of reporting against the WHO benchmarks. Results We identified significant under-reporting and delays in the government's surveillance. On average, EWARS reports were published 24 days (range 12–61) after the reference week compared with 11 days (5–21) for EWARN. Average completeness for EWARS was 75% (55–84%), compared with 92% for EWARN (85–99%). Average timeliness for EWARS was 79% (51–100%), compared with 88% for EWARN (70–97%). EWARS made limited use of rapid diagnostic tests, and rates of collection of stool samples for laboratory cholera testing were well below reference levels. Conclusions In the context of the current Syrian war, the government's surveillance is inadequate due to lack of access to non-government held territory, an incentive to under-report the consequence of government attacks on health infrastructure, and an impractical insistence on laboratory confirmation. These findings should guide the WHO reform for surveillance in conflict zones. PMID:28588951

  6. Biochemical marker reference values across pediatric, adult, and geriatric ages: establishment of robust pediatric and adult reference intervals on the basis of the Canadian Health Measures Survey.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David

    2015-08-01

    Biological covariates such as age and sex can markedly influence biochemical marker reference values, but no comprehensive study has examined such changes across pediatric, adult, and geriatric ages. The Canadian Health Measures Survey (CHMS) collected comprehensive nationwide health information and blood samples from children and adults in the household population and, in collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), examined biological changes in biochemical markers from pediatric to geriatric age, establishing a comprehensive reference interval database for routine disease biomarkers. The CHMS collected health information, physical measurements, and biosamples (blood and urine) from approximately 12 000 Canadians aged 3-79 years and measured 24 biochemical markers with the Ortho Vitros 5600 FS analyzer or a manual microplate. By use of CLSI C28-A3 guidelines, we determined age- and sex-specific reference intervals, including corresponding 90% CIs, on the basis of specific exclusion criteria. Biochemical marker reference values exhibited dynamic changes from pediatric to geriatric age. Most biochemical markers required some combination of age and/or sex partitioning. Two or more age partitions were required for all analytes except bicarbonate, which remained constant throughout life. Additional sex partitioning was required for most biomarkers, except bicarbonate, total cholesterol, total protein, urine iodine, and potassium. Understanding the fluctuations in biochemical markers over a wide age range provides important insight into biological processes and facilitates clinical application of biochemical markers to monitor manifestation of various disease states. The CHMS-CALIPER collaboration addresses this important evidence gap and allows the establishment of robust pediatric and adult reference intervals. © 2015 American Association for Clinical Chemistry.

  7. Retinal vasculitis and cystoid macular edema after body tattooing: a case report.

    PubMed

    Moschos, M M; Guex-Crosier, Y

    2004-05-01

    To report a case of retinal vasculitis occurring after the placement of permanent tattoos. A 21-year-old male was referred to our department with impairment of visual acuity. Permanent tattoos covered the head, body, arms and legs. The patient was examined with ophthalmoscopy, fluorescein angiography, indocyanine green angiography and optical coherence tomography. Systemic medical and laboratory work-up were performed in order to exclude an infectious agent or an inflammatory disease. He had no history of intravenous drug abuse. Our patient presented severe posterior uveitis associated with retinal vasculitis and cystoid macular edema. Laboratory tests ruled out all diseases causing vasculitis. HIV and B, C hepatitis tests were negative. Cystoid macular edema and vasculitis were resolved after immunosuppressive therapy. This is the first description of a retinal vasculitis associated with cystoid macular edema in a completely healthy individual after the placement of permanent tattoos. A phagocytosis of tattoo pigments leading to their lysis is described in the literature as a mechanism causing vasculitis.

  8. Thyroid Ultrasonography in Differentiation between Graves' Disease and Hashimoto's Thyroiditis.

    PubMed

    Pishdad, P; Pishdad, G R; Tavanaa, S; Pishdad, R; Jalli, R

    2017-03-01

    Graves' disease and Hashimoto's thyroiditis are the most common causes of hyper and hypothyroidism, respectively. Differentiation of these 2 diseases, if the patient is euthyroid, may sometimes be extremely difficult on the basis of clinical and laboratory findings. The purpose of this study was to determine the sensitivity and specificity of gray scale sonography in differentiation of Graves' disease from Hashimoto's thyroiditis. This study included 149 patients divided into three groups, patients with Graves' disease (34 patients, mean age = 36.8 ± 10.17 years), Patients with Hashimoto's thyroiditis (62 patients, mean age = 33.4 ± 12.16 years) and control group (53 healthy people, mean age = 34.74 ± 16.87 years). Members of all groups were referred to a single radiologist for thyroid sonography for evaluation of thyroid echogenicity pattern. A total of 117 women and 32 men were examined by sonography. The most common sonographic pattern in Hashimoto and Graves' was homogenous hypo-echogenicity which was observed in 45.2% and 47.1% of cases, respectively. Peripheral hypo-echogenicity pattern was seen in 40.3% of Hashimoto's group with 100% specificity and 40.3% sensitivity. Central-hypoechogenic pattern was observed in 17.6% of Graves' group with 100% and 17.6% specificity and sensitivity, respectively. Our findings indicate that sonography has high specificity but low sensitivity in the diagnosis of either Graves' disease or Hashimoto's thyroiditis. It is therefore not possible to differentiate between these two diseases using sonography alone. Confirmation by laboratory data is also needed.

  9. A UK NEQAS ICC and ISH multicentre study using the Kreatech Poseidon HER2 FISH probe: intersite variation can be rigorously controlled using FISH.

    PubMed

    Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith

    2010-02-01

    To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.

  10. Comparison of results of fluconazole disk diffusion testing for Candida species with results from a central reference laboratory in the ARTEMIS global antifungal surveillance program.

    PubMed

    Pfaller, M A; Hazen, K C; Messer, S A; Boyken, L; Tendolkar, S; Hollis, R J; Diekema, D J

    2004-08-01

    The accuracy of antifungal susceptibility tests is important for accurate resistance surveillance and for the clinical management of patients with serious infections. Our main objective was to compare the results of fluconazole disk diffusion testing of Candida spp. performed by ARTEMIS participating centers with disk diffusion and MIC results obtained by the central reference laboratory. A total of 2,949 isolates of Candida spp. were tested by NCCLS disk diffusion and reference broth microdilution methods in the central reference laboratory. These results were compared to the results of disk diffusion testing performed in the 54 participating centers. All tests were performed and interpreted following NCCLS recommendations. Overall categorical agreement between participant disk diffusion test results and reference laboratory MIC results was 87.4%, with 0.2% very major errors (VME) and 3.3% major errors (ME). The categorical agreement between the disk diffusion test results obtained in the reference laboratory with the MIC test results was similar: 92.8%. Likewise, good agreement was observed between participant disk diffusion test results and reference laboratory disk diffusion test results: 90.4%, 0.4% VME, and 3.4% ME. The disk diffusion test was especially reliable in detecting those isolates of Candida spp. that were characterized as resistant by reference MIC testing. External quality assurance data obtained by surveillance programs such as the ARTEMIS Global Antifungal Surveillance Program ensure the generation of useful surveillance data and result in the continued improvement of antifungal susceptibility testing practices.

  11. Urgent needs in fostering neglected tropical diseases (NTDs) laboratory capacity in WHO Western Pacific Region: results from the external quality assessment on NTDs diagnosis in 2012-2015.

    PubMed

    Lu, Yan; Gonzales, Glenda; Chen, Shao-Hong; Li, Hao; Cai, Yu-Chun; Chu, Yan-Hong; Ai, Lin; Chen, Mu-Xin; Chen, Hai-Ning; Chen, Jia-Xu

    2017-06-08

    Neglected tropical diseases (NTDs) are a heterogeneous group of mainly chronic, debilitating and often stigmatizing diseases that largely affects low-income and politically marginalized populations, causing a large burden of public health, social and economies in the NTDs endemic countries. NTDs are caused by infections with a range of pathogen, including bacteria, parasites, protozoa and viruses. The accurate diagnosis of NTDs is important for reducing morbidity, preventing mortality and for monitoring of control programs. External Quality Assessment (EQA), a component of laboratory quality assurance, aims to assess the performance of participating laboratories in detecting parasitic infections. The aim of this paper is to report the findings and put forward the recommendations on capacity build from the EQA results of participating NTDs laboratories in selected countries in the WHO Western Pacific Region from 2012 to 2015. Reference or public health laboratories at national level working on NTDs in 6 countries participated in EQAs organized by the National Institute of Parasitic Diseases (NIPD) of Chinese Center for Disease Control and Prevention (CDC) based in Shanghai, China. Two representatives of each participating laboratory were invited to NIPD to detect NTDs' parasitic infections using the same prepared samples for serological tests (IHA and ELISA) and helminth eggs' morphological tests (Direct smear and Kato-Katz). All of the results were scored and analyzed by using SPSS statistics 19.0 software. The percentage of participants who had EQA score ≥ 60 during 2012-2015 for direct smear test were 80.00% (2012), 71.43% (2013), 100% (2014) and 75.00% (2015), whereas for Kato-Katz test were 80.00% (2012), 57.14% (2013), 100% (2014) and 37.50% (2015), respectively. The detection rate of helminth eggs varied in different species, with Ascaris lumbricoides being the highest at 94.07% in average. All laboratories did very well with ELISA tests as shown by the high scores in all four years except Lab A in the first and last EQA. For the positive or negative judgments of serum samples, the total coincidence rates of ELISA between 2012 and 2015 were 90.00%, 99.29%, 94.29% and 98.75%, respectively. While the total coincidence rates of IHA were respectively 100%, 95.00%, 90.00% and 97.50%. However, detecting low levels of serum antibody remained problematic for IHA when the titres of samples were taken into consideration. This study demonstrate that EQA scheme have been beneficial to the participating laboratories. The EQA programme identifies certain deficiencies which were needed to overcome and improved the laboratories' performance in helminthiasis diagnosis. However, further optimization of accuracy and uniformity in NTDs diagnosis remains a big challenge.

  12. Food insecurity is associated with chronic disease among low-income NHANES participants.

    PubMed

    Seligman, Hilary K; Laraia, Barbara A; Kushel, Margot B

    2010-02-01

    Food insecurity refers to the inability to afford enough food for an active, healthy life. Numerous studies have shown associations between food insecurity and adverse health outcomes among children. Studies of the health effects of food insecurity among adults are more limited and generally focus on the association between food insecurity and self-reported disease. We therefore examined the association between food insecurity and clinical evidence of diet-sensitive chronic disease, including hypertension, hyperlipidemia, and diabetes. Our population-based sample included 5094 poor adults aged 18-65 y participating in the NHANES (1999-2004 waves). We estimated the association between food insecurity (assessed by the Food Security Survey Module) and self-reported or laboratory/examination evidence of diet-sensitive chronic disease using Poisson regression. We adjusted the models to account for differences in age, gender, race, educational attainment, and income. Food insecurity was associated with self-reported hypertension [adjusted relative risk (ARR) 1.20; 95% CI, 1.04-1.38] and hyperlipidemia (ARR 1.30; 95% CI, 1.09-1.55), but not diabetes (ARR 1.19; 95% CI, 0.89-1.58). Food insecurity was associated with laboratory or examination evidence of hypertension (ARR 1.21; 95% CI, 1.04-1.41) and diabetes (ARR 1.48; 95% CI, 0.94-2.32). The association with laboratory evidence of diabetes did not reach significance in the fully adjusted model unless we used a stricter definition of food insecurity (ARR 2.42; 95% CI, 1.44-4.08). These data show that food insecurity is associated with cardiovascular risk factors. Health policy discussions should focus increased attention on ability to afford high-quality foods for adults with or at risk for chronic disease.

  13. A new multiplex real-time PCR test for HSV1/2 and syphilis: an evaluation of its impact in the laboratory and clinical setting.

    PubMed

    Scott, Laura Jane; Gunson, Rory N; Carman, William F; Winter, Andrew J

    2010-12-01

    To develop, evaluate and implement a new multiplex real-time PCR test for the detection of herpes simplex virus (HSV)1, HSV2 and syphilis in a single sample using a single test. A multiplex real-time PCR test detecting HSV1, HSV2 and Treponema pallidum was designed, validated and evaluated for a period of 6 months on patients attending the Sandyford Initiative (a series of genitourinary medicine clinics in and around Glasgow). A total of 692 samples were tested, and T pallidum PCR positives were confirmed by a second PCR at the Scottish Reference Laboratory (SBSTIRL). All PCR results were aligned with dark ground microscopy findings and serological results where available and compared. The laboratory validation of the multiplex assay showed the test to be sensitive, specific and robust. Of the 692 samples, 139 were positive for HSV1, 136 for HSV2, 15 for syphilis, one for both syphilis and HSV1, and 401 were negative; the reference laboratory confirmed all T pallidum PCR-positive samples. The PCR test was more sensitive than both dark ground microscopy and serological testing for the diagnosis of primary syphilis. The introduction of this new test has led to a better turnaround time for the diagnosis of genital ulcer disease, better detection of primary syphilis infection, and the detection of unexpected cases of syphilis where the aetiological agent suspected was HSV.

  14. Comparison of RFFIT tests with different standard sera and testing procedures.

    PubMed

    Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong

    2012-06-01

    The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.

  15. [Serological screening for Trypanosoma cruzi among blood donors in central Brazil].

    PubMed

    de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F

    1992-07-01

    The present study compares the results of serological screening for Trypanosoma cruzi infection done at blood banks with results obtained in Chagas' disease studies undertaken by the Reference Laboratory of the Federal University of Goiás (UFG) and evaluates the use of the enzyme-linked immunosorbent assay (ELISA) for this purpose. The study was conducted with data from six of the eight blood banks in the city of Goiânia in central Brazil, an urban area in which this infection is highly endemic. The population studied consisted of 1,513 volunteers who had donated blood for the first time between October 1988 and April 1989. The sample represented 50% of all first-time blood donors during the period. Of these donors, 94% were residents of urban areas, and of these, approximately 26% had migrated from the countryside. Nearly 90% of the blood donations in the city are received at these banks, which normally use the indirect hemagglutination and complement-fixation tests. The samples selected for the study of T. cruzi antibody in first-time blood donors were assayed at the Reference Laboratory of the Federal University of Goiás using the indirect hemagglutination (IH), indirect immunofluorescence (IF), and enzyme-linked immunosorbent assay (ELISA) tests, independently of the serological classification performed by the blood banks. Comparison of the results provided by the latter with the positivity pattern established in the study (IH and IF yielded simultaneous positive results in the Reference Laboratory) revealed a relative sensitivity of 77%, with extremes ranging between 50% and 100%, depending on the blood bank studied.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Guidelines for Mass Screening of Congenital Hypothyroidism (2014 revision)

    PubMed Central

    Nagasaki, Keisuke; Minamitani, Kanshi; Anzo, Makoto; Adachi, Masanori; Ishii, Tomohiro; Onigata, Kazumichi; Kusuda, Satoshi; Harada, Shohei; Horikawa, Reiko; Minagawa, Masanori; Mizuno, Haruo; Yamakami, Yuji; Fukushi, Masaru; Tajima, Toshihiro

    2015-01-01

    Purpose of developing the guidelines: Mass screening for congenital hypothyroidism started in 1979 in Japan, and the prognosis for intelligence has been improved by early diagnosis and treatment. The incidence was about 1/4000 of the birth population, but it has increased due to diagnosis of subclinical congenital hypothyroidism. The disease requires continuous treatment, and specialized medical facilities should make a differential diagnosis and treat subjects who are positive in mass screening to avoid unnecessary treatment. The Guidelines for Mass Screening of Congenital Hypothyroidism (1998 version) were developed by the Mass Screening Committee of the Japanese Society for Pediatric Endocrinology in 1998. Subsequently, new findings on prognosis and problems in the adult phase have emerged. Based on these new findings, the 1998 guidelines were revised in the current document (hereinafter referred to as the Guidelines). Target disease/conditions: Primary congenital hypothyroidism. Users of the Guidelines: Physician specialists in pediatric endocrinology, pediatric specialists, physicians referring patients to pediatric practitioners, general physicians, laboratory technicians in charge of mass screening, and patients. PMID:26594093

  17. Characterization of Escherichia coli O157:H7 in New Zealand using multiple-locus variable-number tandem-repeat analysis.

    PubMed

    Dyet, K H; Robertson, I; Turbitt, E; Carter, P E

    2011-03-01

    Recently, multiple-locus variable-number tandem-repeat analysis (MLVA) has been proposed as an alternative to pulsed-field gel electrophoresis (PFGE) for characterization of Escherichia coli O157:H7. In this study we characterized 118 E. coli O157:H7 isolates from cases of gastrointestinal disease in New Zealand using XbaI PFGE profiles and a MLVA scheme that assessed variability in eight polymorphic loci. The 118 isolates characterized included all 80 E. coli O157:H7 referred to New Zealand's Enteric Reference Laboratory in 2006 and 29 phage-type 2 isolates from 2005. When applied to these isolates the discriminatory power of PFGE and MLVA was not significantly different. However, MLVA data may be more epidemiologically relevant as isolates from family clusters of disease had identical MLVA profiles, even when the XbaI PFGE profiles differed slightly. Furthermore, most isolates with indistinguishable XbaI PFGE profiles that did not appear to be epidemiologically related had distinct MLVA profiles.

  18. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in April 2001

    USGS Publications Warehouse

    Woodworth, M.T.; Connor, B.F.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  19. Results of the U. S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2002

    USGS Publications Warehouse

    Woodworth, M.T.; Conner, B.F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  20. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2002

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  1. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2001

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  2. Results of the U.S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2000

    USGS Publications Warehouse

    Farrar, Jerry W.; Copen, Ashley M.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  3. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 1999

    USGS Publications Warehouse

    Farrar, T.W.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  4. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in March 2003

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  5. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 2000

    USGS Publications Warehouse

    Connor, B.F.; Currier, J.P.; Woodworth, M.T.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  6. [Multiorgan autoimmune syndrome: case report].

    PubMed

    Ghiringhelli, Paolo; Chelazzi, Paolo; Chelazzi, Giovanni; Bellintani, Claudio; Rania, Simone

    2003-01-01

    The present case report refers to a multiorgan autoimmune disease manifesting following thymectomy performed for a benign thymoma. This disease is characterized by hypothyroidism, severe myasthenia, polymyositis and alopecia which are organ-specific diseases probably with a different time of onset but which are all an expression of the same immunopathologic process occurring in individuals who have a genetic predisposition. Characteristic of the present case is not only the association of the different immunopathologic clinical pictures but also the rather difficult differential diagnosis between a hypothyroidism-related myopathy and polymyositis. It was possible to formulate the diagnosis by integrating the results of clinical and laboratory evaluation with the therapeutic outcome. The onset of the syndrome was attributed to the withdrawal, following surgery, of the inhibitory effects of the thymoma on some clones of autoreactive lymphocytes.

  7. BiliChek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method.

    PubMed

    Karon, Brad S; Wickremasinghe, Andrea C; Lo, Stanley F; Saenger, Amy K; Cook, Walter J

    2010-08-01

    To determine the relationship between BiliChek TcB (Respironics, Marietta GA) and Doumas reference serum or plasma total bilirubin (TSB). Pooled samples with values assigned by the Doumas reference method were used to establish the relationship between a local laboratory and reference Doumas TSB. We then established the relationship between TcB and TSB in the 3 months before and after reassignment of calibrator setpoints undertaken to match the local laboratory to Doumas reference bilirubin values. Before calibrator setpoint reassignment TSB as measured in our laboratory overestimated Doumas reference bilirubin. After calibrator adjustment laboratory TSB was within 1.7-6.8 micromol/L (0.1-0.4 mg/dL) of Doumas reference values. Mean bias between BiliChek TcB and TSB was 42.8+/-22.2 micromol/L (2.5+/-1.3mg/dL) (n=94) before and 49.6+/-22.2 micromol/L (2.9+/-1.3mg/dL) (n=115) after calibration adjustment. BiliChek TcB significantly overestimates TSB as measured by the Doumas reference method. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Subjects hospitalized with the 2009 pandemic influenza A (H1N1) virus in a respiratory infection unit: clinical factors correlating with ICU admission.

    PubMed

    Rovina, Nikoletta; Erifaki, Magdalini; Katsaounou, Paraskevi; Lyxi, Georgia; Koutsoukou, Antonia; Koulouris, Nikolaos G; Alchanatis, Manos

    2014-10-01

    The 2009 pandemic influenza A (H1N1) virus was accompanied by high morbidity and mortality. The aim of this study was to describe the clinical characteristics of patients with documented 2009 influenza A (H1N1) virus admitted to a reference chest hospital, the disease outcome, and risk factors associated with ICU admission. We assessed 109 subjects admitted to the respiratory infection unit of a hospital for chest disease with signs and symptoms of the 2009 influenza A (H1N1) virus between April 2009 and December 2010. Demographic data, comorbidities, clinical signs and symptoms, laboratory tests, radiographic findings, treatment, and final outcomes were all recorded. Factors associated with severe disease requiring ICU admission were determined. Ninety subjects (82.5%) had laboratory-confirmed 2009 influenza A (H1N1). Sixty-four percent of these subjects had pneumonia on admission, 26% had respiratory failure, and 11% required care in the ICU. Dyspnea and the presence of infiltrates on chest x-rays were the most common signs among the subjects with H1N1. All subjects were treated with antiviral therapy, and 75% received antibiotic treatment based on their clinical and laboratory findings. The predictive factors of ICU admission were severe hypoxemia and lymphocytosis. The outcome of subjects with influenza A (H1N1) virus infection was influenced by the severity of the disease on admission, the subjects' underlying conditions, and complications during hospitalization. Copyright © 2014 by Daedalus Enterprises.

  9. Magnetic Stirrer Method for the Detection of Trichinella Larvae in Muscle Samples.

    PubMed

    Mayer-Scholl, Anne; Pozio, Edoardo; Gayda, Jennifer; Thaben, Nora; Bahn, Peter; Nöckler, Karsten

    2017-03-03

    Trichinellosis is a debilitating disease in humans and is caused by the consumption of raw or undercooked meat of animals infected with the nematode larvae of the genus Trichinella. The most important sources of human infections worldwide are game meat and pork or pork products. In many countries, the prevention of human trichinellosis is based on the identification of infected animals by means of the artificial digestion of muscle samples from susceptible animal carcasses. There are several methods based on the digestion of meat but the magnetic stirrer method is considered the gold standard. This method allows the detection of Trichinella larvae by microscopy after the enzymatic digestion of muscle samples and subsequent filtration and sedimentation steps. Although this method does not require special and expensive equipment, internal controls cannot be used. Therefore, stringent quality management should be applied throughout the test. The aim of the present work is to provide detailed handling instructions and critical control points of the method to analysts, based on the experience of the European Union Reference Laboratory for Parasites and the National Reference Laboratory of Germany for Trichinella.

  10. Microscopic diagnosis of sodium acetate-acetic acid-formalin-fixed stool samples for helminths and intestinal protozoa: a comparison among European reference laboratories.

    PubMed

    Utzinger, J; Botero-Kleiven, S; Castelli, F; Chiodini, P L; Edwards, H; Köhler, N; Gulletta, M; Lebbad, M; Manser, M; Matthys, B; N'Goran, E K; Tannich, E; Vounatsou, P; Marti, H

    2010-03-01

    The present study aimed to compare the diagnostic performance of different European reference laboratories in diagnosing helminths and intestinal protozoa, using an ether-concentration method applied to sodium acetate-acetic acid-formalin (SAF)-preserved faecal samples. In total, 102 stool specimens were analysed during a cross-sectional parasitological survey in urban farming communities in Côte d'Ivoire. Five SAF-preserved faecal samples were prepared from each specimen and forwarded to the participating reference laboratories, processed and examined under a microscope adhering to a standard operating procedure (SOP). Schistosoma mansoni (cumulative prevalence: 51.0%) and hookworm (cumulative prevalence: 39.2%) were the predominant helminths. There was excellent agreement (kappa > 0.8; p < 0.001) among the reference laboratories for the diagnosis of S. mansoni, hookworm, Trichuris trichiura and Ascaris lumbricoides. Moderate agreement (kappa = 0.54) was found for Hymenolepis nana, and lesser agreement was observed for other, less prevalent helminths. The predominant intestinal protozoa were Entamoeba coli (median prevalence: 67.6%), Blastocystis hominis (median prevalence: 55.9%) and Entamoeba histolytica/Entamoeba dispar (median prevalence: 47.1%). Substantial agreement among reference laboratories was found for E. coli (kappa = 0.69), but only fair or moderate agreement was found for other Entamoeba species, Giardia intestinalis and Chilomastix mesnili. There was only poor agreement for B. hominis, Isospora belli and Trichomonas intestinalis. In conclusion, although common helminths were reliably diagnosed by European reference laboratories, there was only moderate agreement between centres for pathogenic intestinal protozoa. Continued external quality assessment and the establishment of a formal network of reference laboratories is necessary to further enhance both accuracy and uniformity in parasite diagnosis.

  11. Provincial Comparison of Pharmacist Prescribing in Canada Using Alberta’s Model as the Reference Point

    PubMed Central

    Bhatia, Surya; Simpson, Scot H; Bungard, Tammy

    2017-01-01

    Background In the past decade, pharmacist practice has evolved tremendously in Canada, but the scope of practice varies substantially from one province to another. Objective To describe pharmacists’ scopes of practice relevant to prescribing within various jurisdictions of Canada, using the prescribing model in Alberta (authors’ province) as the reference point. Methods This cross-sectional survey consisted of clinical scenarios for emergency prescribing, adapting or renewing a prescription, and initial-access prescribing for a chronic disease. Pharmacists were asked about their ability to administer injections and to order or access the results of laboratory tests, as well as certification and training requirements and reimbursement models. Results Thirteen pharmacists representing Canadian provinces other than Alberta were surveyed in late 2015, for comparison with Alberta. With specific reference to the scenarios presented, pharmacists were able to prescribe in an emergency in 9 of the 10 provinces, renew prescriptions in all provinces, and adapt prescriptions in 6 provinces. Three provinces required that pharmacists have collaborative practice agreements identifying a specific practice area in order to initiate a prescription for a chronic disease (with 6–12 pharmacists per province having such agreements). Alberta required pharmacists to have authorization, based on a detailed application, in order to initiate any provincially regulated drug (with about 1150 pharmacists having this authorization). Pharmacists were allowed to administer vaccines in 9 provinces, and 5 provinces allowed pharmacists to administer drugs by injection. Three provinces had systems in place for pharmacists to access laboratory test results, and 2 allowed pharmacists to order laboratory tests. Five provinces had government-reimbursed programs in place for select prescribing services; however, all 9 provinces with public vaccination programs reimbursed pharmacists for this service. Conclusions Pharmacist prescribing differs among Canadian provinces. Although most provinces allow emergency prescribing and renewal or adaptation of prescriptions by pharmacists, only 4 provinces allow prescription initiation, with variable criteria and scope. Despite some progress to enhance patient flow through the health care system (e.g., by allowing pharmacists to extend prescriptions), further work should be pursued to harmonize clinical practices across Canada and to enable pharmacists to initiate and manage drug therapy. PMID:29109578

  12. Patient satisfaction and uptake of private-sector run malaria diagnosis clinics in a post-conflict district in Sri Lanka.

    PubMed

    Fernando, Deepika; de Silva, Nipun Lakshitha; Ackers, Isabella; Abeyasinghe, Rabindra; Wijeyaratne, Pandu; Rajapakse, Senaka

    2014-06-23

    With the incidence of malaria in Sri Lanka declining, intensive parasitological surveillance has been identified as a key strategy to achieve elimination by end 2014. Tropical and Environmental Diseases and Health Associates Private Limited (TEDHA) in collaboration with the Anti-Malaria Campaign established 43 malaria diagnostic laboratories (MDL) in four post-conflict districts of the Northern and Eastern Provinces. This study assesses the patterns of referral of patients with fever for malaria diagnosis by health care providers (HCPs) in four government hospitals in one of the districts of the Northern Province, and patient satisfaction with the laboratory services offered. In this prospective descriptive study, data was collected on the proportion of fever patients being referred by the HCP in hospitals for malaria screening, and the proportion thereof who underwent screening. An interviewer-administered questionnaire was also used to assess patient satisfaction among those attending MDL, which was graded on a scale of 0-4. Of patients presenting to the hospitals with fever, only 44.3% were referred for malaria screening; 81.7% of them underwent screening. Referral depended largely on the presence of a permanent staff HCP. Satisfaction levels were high, with 86.55% giving an overall rating of 4. Comfort within the laboratory was rated satisfactory in three of the four hospitals. This study demonstrates the success of a public-private partnership in the malaria control programme in Sri Lanka. Malaria is considered low on the differential diagnosis in patients with fever even in previously malaria-endemic areas, due to the declining incidence of malaria and the increase in other febrile illnesses in these areas during the recent past. Private sector run malaria diagnostic services provided free of charge within government hospitals are viable and effective, and had good patient satisfaction ratings. In a country on the brink of eliminating malaria, there should be further emphasis on ensuring that HCPs refer patients for malaria diagnosis, in order to prevent a resurgence of the disease.

  13. Experimental infection of snakes with Ophidiomyces ophiodiicola causes pathological changes that typify snake fungal disease

    USGS Publications Warehouse

    Lorch, Jeffrey M.; Lankton, Julia S.; Werner, Katrien; Falendysz, Elizabeth A.; McCurley, Kevin; Blehert, David S.

    2015-01-01

    IMPORTANCE Skin infections in snakes, referred to as snake fungal disease (SFD), have been reported with increasing frequency in wild snakes in the eastern United States. While most of these infections are associated with the fungusOphidiomyces ophiodiicola, there has been no conclusive evidence to implicate this fungus as a primary pathogen. Furthermore, it is not understood why the infections affect different host populations differently. Our experiment demonstrates that O. ophiodiicola is the causative agent of SFD and can elicit pathological changes that likely impact fitness of wild snakes. This information, and the laboratory model we describe, will be essential in addressing unresolved questions regarding disease ecology and outcomes of O. ophiodiicola infection and helping to conserve snake populations threatened by the disease. The SFD model of infection also offers utility for exploring larger concepts related to comparative fungal virulence, host response, and host-pathogen evolution.

  14. First proficiency testing to evaluate the ability of European Union National Reference Laboratories to detect staphylococcal enterotoxins in milk products.

    PubMed

    Hennekinne, Jacques-Antoine; Gohier, Martine; Maire, Tiphaine; Lapeyre, Christiane; Lombard, Bertrand; Dragacci, Sylviane

    2003-01-01

    The European Commission has designed a network of European Union-National Reference Laboratories (EU-NRLs), coordinated by a Community Reference Laboratory (CRL), for control of hygiene of milk and milk products (Council Directive 92/46/ECC). As a common contaminant of milk and milk products such as cheese, staphylococcal enterotoxins are often involved in human outbreaks and should be monitored regularly. The main tasks of the EU-CRLs were to select and transfer to the EU-NRLs a reference method for detection of enterotoxins, and to set up proficiency testing to evaluate the competency of the European laboratory network. The first interlaboratory exercise was performed on samples of freeze-dried cheese inoculated with 2 levels of staphylococcal enterotoxins (0.1 and 0.25 ng/g) and on an uninoculated control. These levels were chosen considering the EU regulation for staphylococcal enterotoxins in milk and milk products and the limit of detection of the enzyme-linked immunosorbent assay test recommended in the reference method. The trial was conducted according to the recommendations of ISO Guide 43. Results produced by laboratories were compiled and compared through statistical analysis. Except for data from 2 laboratories for the uninoculated control and cheese inoculated at 0.1 ng/g, all laboratories produced satisfactory results, showing the ability of the EU-NRL network to monitor the enterotoxin contaminant.

  15. 'Aussie normals': an a priori study to develop clinical chemistry reference intervals in a healthy Australian population.

    PubMed

    Koerbin, G; Cavanaugh, J A; Potter, J M; Abhayaratna, W P; West, N P; Glasgow, N; Hawkins, C; Armbruster, D; Oakman, C; Hickman, P E

    2015-02-01

    Development of reference intervals is difficult, time consuming, expensive and beyond the scope of most laboratories. The Aussie Normals study is a direct a priori study to determine reference intervals in healthy Australian adults. All volunteers completed a health and lifestyle questionnaire and exclusion was based on conditions such as pregnancy, diabetes, renal or cardiovascular disease. Up to 91 biochemical analyses were undertaken on a variety of analytical platforms using serum samples collected from 1856 volunteers. We report on our findings for 40 of these analytes and two calculated parameters performed on the Abbott ARCHITECTci8200/ci16200 analysers. Not all samples were analysed for all assays due to volume requirements or assay/instrument availability. Results with elevated interference indices and those deemed unsuitable after clinical evaluation were removed from the database. Reference intervals were partitioned based on the method of Harris and Boyd into three scenarios, combined gender, males and females and age and gender. We have performed a detailed reference interval study on a healthy Australian population considering the effects of sex, age and body mass. These reference intervals may be adapted to other manufacturer's analytical methods using method transference.

  16. External Quality Assessment Scheme for reference laboratories - review of 8 years' experience.

    PubMed

    Kessler, Anja; Siekmann, Lothar; Weykamp, Cas; Geilenkeuser, Wolf Jochen; Dreazen, Orna; Middle, Jonathan; Schumann, Gerhard

    2013-05-01

    We describe an External Quality Assessment Scheme (EQAS) intended for reference (calibration) laboratories in laboratory medicine and supervised by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine and the responsible Committee on Traceability in Laboratory Medicine. The official EQAS website, RELA (www.dgkl-rfb.de:81), is open to interested parties. Information on all requirements for participation and results of surveys are published annually. As an additional feature, the identity of every participant in relation to the respective results is disclosed. The results of various groups of measurands (metabolites and substrates, enzymes, electrolytes, glycated hemoglobins, proteins, hormones, thyroid hormones, therapeutic drugs) are discussed in detail. The RELA system supports reference measurement laboratories preparing for accreditation according to ISO 17025 and ISO 15195. Participation in a scheme such as RELA is one of the requirements for listing of the services of a calibration laboratory by the Joint Committee on Traceability in Laboratory Medicine.

  17. Feline leprosy due to Candidatus 'Mycobacterium lepraefelis': Further clinical and molecular characterisation of eight previously reported cases and an additional 30 cases.

    PubMed

    O'Brien, Carolyn R; Malik, Richard; Globan, Maria; Reppas, George; McCowan, Christina; Fyfe, Janet A

    2017-09-01

    This paper, the last in a series of three on 'feline leprosy', provides a detailed description of disease referable to the previously unnamed species, Candidatus 'Mycobacterium lepraefelis', a close relative of the human pathogens Mycobacterium leprae and Mycobacterium lepromatosis. Cases were sourced retrospectively and prospectively for this observational study, describing clinical, geographical and molecular microbiological data for cats definitively diagnosed with Candidatus 'M lepraefelis' infection. A total of 145 cases of feline leprosy were scrutinised; 114 'new' cases were sourced from the Victorian Infectious Diseases Reference Laboratory (VIDRL) records, veterinary pathology laboratories or veterinarians, and 31 cases were derived from six published studies. Thirty-eight cats were definitively diagnosed with Candidatus 'M lepraefelis' infection. Typically, cats tended to be middle-aged or older when first infected, with a male predilection. Affected cats typically had widespread cutaneous lesions, in some cases after initially localised disease. Advanced cases were often systemically unwell. All cats had outdoor access. The histological picture was lepromatous in the majority of patients, although two cases had tuberculoid disease. In one case that underwent necropsy, lesions were evident in the liver, spleen and lungs. Treatment was varied, although most cats received a combination of oral clarithromycin and rifampicin. Prognosis for recovery was variable, but typically poor. Candidatus 'M lepraefelis' typically causes high bacterial index (lepromatous) feline leprosy that in some cases progresses to systemic mycobacteriosis. The disease has a variable clinical course and prognosis. Many cases either died or were euthanased due to the infection. Multilocus sequence analysis reveals a heterogeneous picture and further analysis of draft genome sequencing may give clues to the taxonomy and epidemiology of this organism. Prospective treatment trials and/or additional drug susceptibility testing in specialised systems would further inform treatment recommendations. Comparative aspects: This paper finishes with a discussion of comparative aspects of infection caused by the three feline leproid disease agents that have been the subject of this series: Candidatus 'Mycobacterium tarwinense', Mycobacterium lepraemurium and Candidatus 'M lepraefelis'.

  18. An automated and objective method for age partitioning of reference intervals based on continuous centile curves.

    PubMed

    Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping

    2016-10-01

    Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  19. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  20. Monitoring of anticoagulant therapy in heart disease: considerations for the current assays.

    PubMed

    Boroumand, Mohammadali; Goodarzynejad, Hamidreza

    2010-01-01

    Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to "normalize" all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation, and congenital factor deficiencies. In contrast to marked progress in the standardization of PT reagents for INR reporting, no standardization system has been globally adopted for standardization of PTT reagents. Recently College of American Pathologists recommend that individual laboratories establish their own therapeutic range by using aPTT values calibrated against accepted therapeutic unfractionated heparin (UFH) levels calibrated against accepted therapeutic UFH levels performing anti-Xa test (which is the most accurate assay for monitoring UFH therapy).Herein, we review recent data on the monitoring of conventional anticoagulant agents. Marked interlaboratory variability still exists for PT, INR, and PTT tests. Further research should be focused on improving the standardization and calibration of these assays.

  1. Performance in Measurement of Serum Cystatin C by Laboratories Participating in the College of American Pathologists 2014 CYS Survey.

    PubMed

    Eckfeldt, John H; Karger, Amy B; Miller, W Greg; Rynders, Gregory P; Inker, Lesley A

    2015-07-01

    Cystatin C is becoming an increasingly popular biomarker for estimating glomerular filtration rate, and accurate measurements of cystatin C concentrations are necessary for accurate estimates of glomerular filtration rate. To assess the accuracy of cystatin C concentration measurements in laboratories participating in the College of American Pathologists CYS Survey. Two fresh frozen serum pools, the first from apparently healthy donors and the second from patients with chronic kidney disease, were prepared and distributed to laboratories participating in the CYS Survey along with the 2 usual processed human plasma samples. Target values were established for each pool by using 2 immunoassays and ERM DA471/IFCC international reference material. For the normal fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.960 mg/L), the all-method mean (SD, % coefficient of variation [CV]) reported by all of the 123 reporting laboratories was 0.894 mg/L (0.128 mg/L, 14.3%). For the chronic kidney disease pool (ERM-DA471/IFCC-traceable target of 2.37 mg/L), the all-method mean (SD, %CV) was 2.258 mg/L (0.288 mg/L, 12.8%). There were substantial method-specific biases (mean milligram per liter reported for the normal pool was 0.780 for Siemens, 0.870 for Gentian, 0.967 for Roche, 1.061 for Diazyme, and 0.970 for other/not specified reagents; and mean milligram per liter reported for the chronic kidney disease pool was 2.052 for Siemens, 2.312 for Gentian, 2.247 for Roche, 2.909 for Diazyme, and 2.413 for other/not specified reagents). Manufacturers need to improve the accuracy of cystatin C measurement procedures if cystatin C is to achieve its full potential as a biomarker for estimating glomerular filtration rate.

  2. Laboratory database population surveillance to improve detection of progressive chronic kidney disease.

    PubMed

    Kennedy, David M; Chatha, Kamaljit; Rayner, Hugh C

    2013-09-01

    Some patients with chronic kidney disease are still referred late for specialist care despite the evidence that earlier detection and intervention can halt or delay progression to end-stage kidney disease (ESKD). To develop a population surveillance system using existing laboratory data to enable early detection of patients at high risk of ESKD by reviewing cumulative graphs of estimated glomerular filtration rate (eGFR). A database was developed, updated daily with data from the laboratory computer. Cumulative eGFR graphs containing up to five years of data are reviewed by clinical scientists for all primary care patients or out-patients with a low eGFR for their age. For those with a declining trend, a report containing the eGFR graph is sent to the requesting doctor. A retrospective audit was performed using historical data to assess the predictive value of the graphs. In nine months, we reported 370,000 eGFR results, reviewing 12,000 eGFR graphs. On average 60 graphs per week were flagged as 'high' or 'intermediate' risk. Patients with graphs flagged as high risk had a significantly higher mortality after 3.5 years and a significantly greater chance of requiring renal replacement therapy after 4.5 years of follow-up. Five patients (7%) with graphs flagged as high risk had a sustained >25% fall in eGFR without evidence of secondary care referral. Feedback about the service from requesting clinicians was 73% positive. We have developed a system for laboratory staff to review cumulative eGFR graphs for a large population and identify patients at highest risk of developing ESKD. Further research is needed to measure the impact of this service on patient outcomes. © 2013 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  3. [Establishing biological reference intervals of alanine transaminase for clinical laboratory stored database].

    PubMed

    Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen

    2015-08-25

    To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.

  4. Establishment of Traceability of Reference Grade Hydrometers at National Physical Laboratory, India (npli)

    NASA Astrophysics Data System (ADS)

    Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.

    The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.

  5. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes: A GeT-RM Collaborative Project.

    PubMed

    Pratt, Victoria M; Everts, Robin E; Aggarwal, Praful; Beyer, Brittany N; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A; Smith, Chingying Huang; Toji, Lorraine H; Turner, Amy; Kalman, Lisa V

    2016-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  6. Report on the U.S. Geological Survey's Evaluation Program Standard Reference Samples Distributed in October 1995: T-137 (Trace Constituents), M-136 (Major Constituents), N-47 (Nutrient Constituents), N-48 (Nutrient Constituents), P-25 (Low Ionic Strength Constituents), and Hg-21 (Mercury)

    USGS Publications Warehouse

    Farrar, Jerry W.; Long, H. Keith

    1996-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  7. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1994; T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), and Hg-18 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  8. Report of the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1993; T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents, N-38 (nutrients), N-39 (nutrients), P-20 (low ionic strength, and Hg-16 (mercury)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1993-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  9. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples distributed in March 1999

    USGS Publications Warehouse

    Farrar, Jerry W.; Chleboun, Kimberly M.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  10. Evaluation of a Spotted Fever Group Rickettsia Public Health Surveillance System in Tennessee.

    PubMed

    Fill, Mary-Margaret A; Moncayo, Abelardo C; Bloch, Karen C; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-09-01

    Spotted fever group (SFG) rickettsioses are endemic in Tennessee, with ∼2,500 cases reported during 2000-2012. Because of this substantial burden of disease, we performed a three-part evaluation of Tennessee's routine surveillance for SFG rickettsioses cases and deaths to assess the system's effectiveness. Tennessee Department of Health (TDH) SFG rickettsioses surveillance records were matched to three patient series: 1) patients with positive serologic specimens from a commercial reference laboratory during 2010-2011, 2) tertiary medical center patients with positive serologic tests during 2007-2013, and 3) patients identified from death certificates issued during 1995-2014 with SFG rickettsiosis-related causes of death. Chart reviews were performed and patients were classified according to the Council of State and Territorial Epidemiologists' case definition. Of 254 SFG Rickettsia -positive serologic specimens from the reference laboratory, 129 (51%) met the case definition for confirmed or probable cases of rickettsial disease after chart review. The sensitivity of the TDH surveillance system to detect cases was 45%. Of the 98 confirmed or probable cases identified from the medical center, the sensitivity of the TDH surveillance system to detect cases was 34%. Of 27 patients identified by death certificates, 12 (44%) were classified as confirmed or probable cases; four (33%) were reported to TDH, but none were correctly identified as deceased. Cases of SFG rickettsioses were underreported and fatalities not correctly identified. Efforts are needed to improve SFG rickettsiosis surveillance in Tennessee.

  11. Cost analysis of an integrated vaccine-preventable disease surveillance system in Costa Rica.

    PubMed

    Toscano, C M; Vijayaraghavan, M; Salazar-Bolaños, H M; Bolaños-Acuña, H M; Ruiz-González, A I; Barrantes-Solis, T; Fernández-Vargas, I; Panero, M S; de Oliveira, L H; Hyde, T B

    2013-07-02

    Following World Health Organization recommendations set forth in the Global Framework for Immunization Monitoring and Surveillance, Costa Rica in 2009 became the first country to implement integrated vaccine-preventable disease (iVPD) surveillance, with support from the U.S. Centers for Disease Control and Prevention (CDC) and the Pan American Health Organization (PAHO). As surveillance for diseases prevented by new vaccines is integrated into existing surveillance systems, these systems could cost more than routine surveillance for VPDs targeted by the Expanded Program on Immunization. We estimate the costs associated with establishing and subsequently operating the iVPD surveillance system at a pilot site in Costa Rica. We retrospectively collected data on costs incurred by the institutions supporting iVPD surveillance during the preparatory (January 2007 through August 2009) and implementation (September 2009 through August 2010) phases of the iVPD surveillance project in Costa Rica. These data were used to estimate costs for personnel, meetings, infrastructure, office equipment and supplies, transportation, and laboratory facilities. Costs incurred by each of the collaborating institutions were also estimated. During the preparatory phase, the estimated total cost was 128,000 U.S. dollars (US$), including 64% for personnel costs. The preparatory phase was supported by CDC and PAHO. The estimated cost for 1 year of implementation was US$ 420,000, including 58% for personnel costs, 28% for laboratory costs, and 14% for meeting, infrastructure, office, and transportation costs combined. The national reference laboratory and the PAHO Costa Rica office incurred 64% of total costs, and other local institutions supporting iVPD surveillance incurred the remaining 36%. Countries planning to implement iVPD surveillance will require adequate investments in human resources, laboratories, data management, reporting, and investigation. Our findings will be valuable for decision makers and donors planning and implementing similar strategies in other countries. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Cost analysis of an integrated vaccine-preventable disease surveillance system in Costa Rica✩

    PubMed Central

    Toscano, C.M.; Vijayaraghavan, M.; Salazar-Bolaños, H.M.; Bolaños-Acuña, H.M.; Ruiz-González, A.I.; Barrantes-Solis, T.; Fernández-Vargas, I.; Panero, M.S.; de Oliveira, L.H.; Hyde, T.B.

    2015-01-01

    Introduction Following World Health Organization recommendations set forth in the Global Framework for Immunization Monitoring and Surveillance, Costa Rica in 2009 became the first country to implement integrated vaccine-preventable disease (iVPD) surveillance, with support from the U.S. Centers for Disease Control and Prevention (CDC) and the Pan American Health Organization (PAHO). As surveillance for diseases prevented by new vaccines is integrated into existing surveillance systems, these systems could cost more than routine surveillance for VPDs targeted by the Expanded Program on Immunization. Objectives We estimate the costs associated with establishing and subsequently operating the iVPD surveillance system at a pilot site in Costa Rica. Methods We retrospectively collected data on costs incurred by the institutions supporting iVPD surveillance during the preparatory (January 2007 through August 2009) and implementation (September 2009 through August 2010) phases of the iVPD surveillance project in Costa Rica. These data were used to estimate costs for personnel, meetings, infrastructure, office equipment and supplies, transportation, and laboratory facilities. Costs incurred by each of the collaborating institutions were also estimated. Results During the preparatory phase, the estimated total cost was 128,000 U.S. dollars (US$), including 64% for personnel costs. The preparatory phase was supported by CDC and PAHO. The estimated cost for 1 year of implementation was US$ 420,000, including 58% for personnel costs, 28% for laboratory costs, and 14% for meeting, infrastructure, office, and transportation costs combined. The national reference laboratory and the PAHO Costa Rica office incurred 64% of total costs, and other local institutions supporting iVPD surveillance incurred the remaining 36%. Conclusions Countries planning to implement iVPD surveillance will require adequate investments in human resources, laboratories, data management, reporting, and investigation. Our findings will be valuable for decision makers and donors planning and implementing similar strategies in other countries. PMID:23777698

  13. Feline leprosy due to Candidatus 'Mycobacterium tarwinense':Further clinical and molecular characterisation of 15 previously reported cases and an additional 27 cases

    PubMed

    O'Brien, Carolyn R; Malik, Richard; Globan, Maria; Reppas, George; McCowan, Christina; Fyfe, Janet A

    2017-05-01

    This paper, the first in a series of three on 'feline leprosy', provides a detailed description of disease referable to Candidatus 'Mycobacterium tarwinense', the most common cause of feline leprosy in Victoria, Australia. Cases were sourced retrospectively and prospectively for this observational study, describing clinical, geographical and molecular microbiological data for cats definitively diagnosed with Candidatus 'M tarwinense' infection. A total of 145 cases of feline leprosy were scrutinised; 114 'new' cases were sourced from the Victorian Infectious Diseases Reference Laboratory records, veterinary pathology laboratories or veterinarians, and 31 cases were derived from six published studies. Forty-two cats were definitively diagnosed with Candidatus 'M tarwinense' infection. Typically, cats were between 3 and 11 years of age, with no gender predilection, and were generally systemically well. All had outdoor access. Most cats underwent surgical resection of lesions with adjunctive medical therapy, often utilising a combination of oral clarithromycin and rifampicin for at least 3 months. Prognosis for recovery was generally good. Resolution of lesions was not observed in the absence of treatment, but a number of untreated cats continued to enjoy an acceptable quality of life despite persistence of the disease, which extended locally but did not appear to disseminate to internal organs. Preliminary results of draft genome sequencing confirmed that the species is a member of the Mycobacterium simiae complex. Candidatus 'M tarwinense', a fastidious member of the M simiae complex, is capable of causing feline leprosy with a tendency to produce lesions on the head, particularly involving the eyes and periocular skin. The disease has an indolent clinical course and generally responds favourably to therapy despite lesions often containing large numbers of organisms. Detailed genomic analysis may yield clues as to the environmental niche and culture requirement of this elusive organism. Prospective treatment trials and/or drug susceptibility testing in specialised systems would further inform treatment recommendations.

  14. Clinical laboratory assessments for Mycoplasma genitalium in a high-prevalence sexually-transmitted infection community reveal epidemiologic dichotomies with Trichomonas vaginalis.

    PubMed

    Munson, Erik; Munson, Kimber L; Schell, Ronald F

    2017-02-01

    Mycoplasma genitalium is an emerging agent of sexually-transmitted infection and is responsible for clinically-significant genital tract disease in both females and males. Similar to scenarios recently experienced with the urogenital flagellate Trichomonas vaginalis, an evolving molecular diagnostic reference standard based on transcription-mediated amplification allows for accurate detection of the organism, plus additional insight into disease epidemiology. Areas covered. The basis for this article includes primary peer-reviewed literature plus compilations of data derived from routine clinical laboratory screening of females and males for agents of sexually-transmitted infection. Introductory laboratory and epidemiologic data related to T. vaginalis provides not only a foreshadowing to the dichotomies inherent to M. genitalium prevalence but also advocacy of a common non-invasive specimen source that could be used to screen females for both agents. This review also documents increased prevalence rates of M. genitalium in both females and males by way of transcription-mediated amplification. Expert commentary. Molecular detection of M. genitalium should be a consideration in the development of comprehensive sexually-transmitted infection screening programs for both females and males. Transcription-mediated amplification has additionally identified novel facets of M. genitalium and T. vaginalis epidemiology that warrant further investigation.

  15. Harmonization in laboratory medicine: Requests, samples, measurements and reports.

    PubMed

    Plebani, Mario

    2016-01-01

    In laboratory medicine, the terms "standardization" and "harmonization" are frequently used interchangeably as the final goal is the same: the equivalence of measurement results among different routine measurement procedures over time and space according to defined analytical and clinical quality specifications. However, the terms define two distinct, albeit closely linked, concepts based on traceability principles. The word "standardization" is used when results for a measurement are equivalent and traceable to the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure (RMP). "Harmonization" is generally used when results are equivalent, but neither a high-order primary reference material nor a reference measurement procedure is available. Harmonization is a fundamental aspect of quality in laboratory medicine as its ultimate goal is to improve patient outcomes through the provision of accurate and actionable laboratory information. Patients, clinicians and other healthcare professionals assume that clinical laboratory tests performed by different laboratories at different times on the same sample and specimen can be compared, and that results can be reliably and consistently interpreted. Unfortunately, this is not necessarily the case, because many laboratory test results are still highly variable and poorly standardized and harmonized. Although the initial focus was mainly on harmonizing and standardizing analytical processes and methods, the scope of harmonization now also includes all other aspects of the total testing process (TTP), such as terminology and units, report formats, reference intervals and decision limits as well as tests and test profiles, requests and criteria for interpretation. Several projects and initiatives aiming to improve standardization and harmonization in the testing process are now underway. Laboratory professionals should therefore step up their efforts to provide interchangeable and comparable laboratory information in order to ultimately assure better diagnosis and treatment in patient care.

  16. Thyroid Ultrasonography in Differentiation between Graves’ Disease and Hashimoto’s Thyroiditis

    PubMed Central

    Pishdad, P.; Pishdad, G.R.; Tavanaa, S.; Pishdad, R.; Jalli, R.

    2017-01-01

    Objective: Graves’ disease and Hashimoto’s thyroiditis are the most common causes of hyper and hypothyroidism, respectively. Differentiation of these 2 diseases, if the patient is euthyroid, may sometimes be extremely difficult on the basis of clinical and laboratory findings. The purpose of this study was to determine the sensitivity and specificity of gray scale sonography in differentiation of Graves’ disease from Hashimoto’s thyroiditis. Methods: This study included 149 patients divided into three groups, patients with Graves’ disease (34 patients, mean age = 36.8 ± 10.17 years), Patients with Hashimoto’s thyroiditis (62 patients, mean age = 33.4 ± 12.16 years) and control group (53 healthy people, mean age = 34.74 ± 16.87 years). Members of all groups were referred to a single radiologist for thyroid sonography for evaluation of thyroid echogenicity pattern. Results: A total of 117 women and 32 men were examined by sonography. The most common sonographic pattern in Hashimoto and Graves’ was homogenous hypo-echogenicity which was observed in 45.2% and 47.1% of cases, respectively. Peripheral hypo-echogenicity pattern was seen in 40.3% of Hashimoto’s group with 100% specificity and 40.3% sensitivity. Central-hypoechogenic pattern was observed in 17.6% of Graves’ group with 100% and 17.6% specificity and sensitivity, respectively. Conclusion: Our findings indicate that sonography has high specificity but low sensitivity in the diagnosis of either Graves’ disease or Hashimoto’s thyroiditis. It is therefore not possible to differentiate between these two diseases using sonography alone. Confirmation by laboratory data is also needed. PMID:28451576

  17. Species identification of Aspergillus, Fusarium and Mucorales with direct surface analysis by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    De Carolis, E; Posteraro, B; Lass-Flörl, C; Vella, A; Florio, A R; Torelli, R; Girmenia, C; Colozza, C; Tortorano, A M; Sanguinetti, M; Fadda, G

    2012-05-01

    Accurate species discrimination of filamentous fungi is essential, because some species have specific antifungal susceptibility patterns, and misidentification may result in inappropriate therapy. We evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for species identification through direct surface analysis of the fungal culture. By use of culture collection strains representing 55 species of Aspergillus, Fusarium and Mucorales, a reference database was established for MALDI-TOF MS-based species identification according to the manufacturer's recommendations for microflex measurements and MALDI BioTyper 2.0 software. The profiles of young and mature colonies were analysed for each of the reference strains, and species-specific spectral fingerprints were obtained. To evaluate the database, 103 blind-coded fungal isolates collected in the routine clinical microbiology laboratory were tested. As a reference method for species designation, multilocus sequencing was used. Eighty-five isolates were unequivocally identified to the species level (≥99% sequence similarity); 18 isolates producing ambiguous results at this threshold were initially rated as identified to the genus level only. Further molecular analysis definitively assigned these isolates to the species Aspergillus oryzae (17 isolates) and Aspergillus flavus (one isolate), concordant with the MALDI-TOF MS results. Excluding nine isolates that belong to the fungal species not included in our reference database, 91 (96.8%) of 94 isolates were identified by MALDI-TOF MS to the species level, in agreement with the results of the reference method; three isolates were identified to the genus level. In conclusion, MALDI-TOF MS is suitable for the routine identification of filamentous fungi in a medical microbiology laboratory. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  18. Similarities and differences between older and young adult patients with celiac disease.

    PubMed

    Kalkan, Çağdaş; Karakaya, Fatih; Soykan, Irfan

    2017-11-01

    Celiac disease is an autoimmune enteropathy with variable clinical symptoms. Elderly patients can have different manifestations from those of young patients. The aims of the present study were to investigate whether any differences or similarities exist between older and young patients with celiac disease with a special emphasis on concurrent autoimmune diseases. Celiac disease patients were stratified as older and younger patients. These two groups were then compared by means of clinical symptoms, laboratory parameters and concurrent autoimmune diseases. Factors associated with the presence of an autoimmune disease were identified by univariate and multivariate analysis. There were 66 older patients (mean age 67.7 ± 3.2 years, 50 women), and 277 younger patients (mean age 35.9 ± 11.7 years, 207 women). Of the 66 older patients, eight patients had gastrointestinal symptoms and 58 patients had extradigestive symptoms. In the younger group, the number of patients referred due to gastrointestinal symptoms was higher (8 [12.2%] vs 200 (72.2%), P < 0.001) compared with the older group. Whereas 10 (15.1%) older patients showed polyautoimmunity, 55 (19.8%) younger patients had polyautoimmunity. Multiple autoimmune syndrome was more common in older patients compared with young patients (31 [47%] vs 12 [4%], P < 0.001, respectively). The presentation of celiac disease clinically, histologically and by means of laboratory parameters is different in older and young patients. Polyautoimmunity and multiple autoimmune syndrome are more common in older patients compared with younger patients. A biopsy score of Marsh score type, antinuclear antibody positivity, high serum anti-tissue transglutaminase immunoglobulin A level and low hemoglobin level were risk factors for having an autoimmune disease. Geriatr Gerontol Int 2017; 17: 2060-2067. © 2017 Japan Geriatrics Society.

  19. Reference Values for TSH and Free Thyroid Hormones in Healthy Pregnant Women in Poland: A Prospective, Multicenter Study.

    PubMed

    Kostecka-Matyja, Marta; Fedorowicz, Anna; Bar-Andziak, Ewa; Bednarczuk, Tomasz; Buziak-Bereza, Monika; Dumnicka, Paulina; Górska, Maria; Krasnodębska, Małgorzata; Niedźwiedzka, Beata; Pach, Dorota; Ruchała, Marek; Siewko, Katarzyna; Solnica, Bogdan; Sowiński, Jerzy; Szelachowska, Małgorzata; Trofimiuk-Müldner, Małgorzata; Wachowiak-Ochmańska, Katarzyna; Hubalewska-Dydejczyk, Alicja

    2017-04-01

    The diagnosis and treatment of thyroid diseases in pregnant women remains a challenge. Various medical associations recommend establishing the reference intervals for thyroid hormones by a local laboratory. Considering differences within geophysical, socioeconomic conditions, and iodine prophylaxis in various populations, it is advisable to assess reference intervals for thyroid hormones specific to a region of residence. The objective was to assess trimester-specific reference intervals for TSH, fT 3 , and fT 4 for pregnant women in the Polish population. We conducted a prospective study in 4 centers representing different regions of Poland (Krakow, Warsaw, Poznan, and Bialystok). Our study included consecutive, healthy pregnant women (172 patients), with an age range of 27-47 years. All women had a negative history for thyroid diseases, normal thyroid peroxidase antibody levels, and proper iodine prophylaxis. All newborns had TSH levels in the appropriate reference range. Serum TSH, fT 3 , fT 4 , and thyroid-peroxidase antibodies were measured in each trimester. The reference intervals were calculated using the percentile method, as recommended by the International Federation of Clinical Chemistry. The reference values calculated were 0.009-3.177, 0.05-3.442, and 0.11-3.53 mIU/L for TSH; 3.63-6.55, 3.29-5.45, and 3.1-5.37 pmol/L for fT 3 ; and 11.99-21.89, 10.46-16.67, and 8.96-17.23 pmol/L for fT 4 in consecutive trimesters of pregnancy. Reference intervals for pregnant women when compared to the general population showed a lower concentration of TSH in every trimester of pregnancy and lower fT 4 in the 2nd and 3rd trimesters. Using appropriate trimester-specific reference intervals may improve care of pregnant women by preventing misdiagnosis and inadequate treatment.

  20. Viral encephalitis of tilapia larvae: primary characterization of a novel herpes-like virus.

    PubMed

    Shlapobersky, Mark; Sinyakov, Michael S; Katzenellenbogen, Mark; Sarid, Ronit; Don, Jeremy; Avtalion, Ramy R

    2010-04-10

    We report here an outbreak of an acute disease that caused high mortality rate in laboratory-reared tilapia larvae. The disease was initially observed in inbred gynogenetic line of blue tilapia larvae (Oreochromis aureus) and could be transmitted to larvae of other tilapia species. Based on the clinical manifestation (a whirling syndrome), we refer to the disease as viral encephalitis of tilapia larvae. The disease-associated DNA virus is described and accordingly designated tilapia larvae encephalitis virus (TLEV). A primary morphological, biophysical and molecular characterization of TLEV is presented. By virtue of these properties, the newly discovered virus is a herpes-like virus. Phylogenetic analysis, albeit limited, confirms this assumption and places TLEV within the family of Herpesviridae and distantly from the families Alloherpesviridae and Iridoviridae. By using PCR with virus-specific primers, diseased larvae and adult TLEV carriers were also identified in tilapia delivered from external hatcheries. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Instantaneous progression reference frame for calculating pelvis rotations: Reliable and anatomically-meaningful results independent of the direction of movement.

    PubMed

    Kainz, Hans; Lloyd, David G; Walsh, Henry P J; Carty, Christopher P

    2016-05-01

    In motion analysis, pelvis angles are conventionally calculated as the rotations between the pelvis and laboratory reference frame. This approach assumes that the participant's motion is along the anterior-posterior laboratory reference frame axis. When this assumption is violated interpretation of pelvis angels become problematic. In this paper a new approach for calculating pelvis angles based on the rotations between the pelvis and an instantaneous progression reference frame was introduced. At every time-point, the tangent to the trajectory of the midpoint of the pelvis projected into the horizontal plane of the laboratory reference frame was used to define the anterior-posterior axis of the instantaneous progression reference frame. This new approach combined with the rotation-obliquity-tilt rotation sequence was compared to the conventional approach using the rotation-obliquity-tilt and tilt-obliquity-rotation sequences. Four different movement tasks performed by eight healthy adults were analysed. The instantaneous progression reference frame approach was the only approach that showed reliable and anatomically meaningful results for all analysed movement tasks (mean root-mean-square-differences below 5°, differences in pelvis angles at pre-defined gait events below 10°). Both rotation sequences combined with the conventional approach led to unreliable results as soon as the participant's motion was not along the anterior-posterior laboratory axis (mean root-mean-square-differences up to 30°, differences in pelvis angles at pre-defined gait events up to 45°). The instantaneous progression reference frame approach enables the gait analysis community to analysis pelvis angles for movements that do not follow the anterior-posterior axis of the laboratory reference frame. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Quality assurance of reference standards from nine European solar-ultraviolet monitoring laboratories.

    PubMed

    Gröbner, Julian; Rembges, Diana; Bais, Alkiviadis F; Blumthaler, Mario; Cabot, Thierry; Josefsson, Weine; Koskela, Tapani; Thorseth, Trond M; Webb, Ann R; Wester, Ulf

    2002-07-20

    A program for quality assurance of reference standards has been initiated among nine solar-UV monitoring laboratories. By means of a traveling lamp package that comprises several 1000-W ANSI code DXW-type quartz-halogen lamps, a 0.1-ohm shunt, and a 6-1/2 digit voltmeter, the irradiance scales used by the nine laboratories were compared with one another; a relative uncertainty of 1.2% was found. The comparison of 15 reference standards yielded differences of as much as 9%; the average difference was less than 3%.

  3. Retrospective analysis of clinical information in Crimean-Congo haemorrhagic fever patients: 2014-2015, India

    PubMed Central

    Mourya, Devendra T.; Viswanathan, Rajlakshmi; Jadhav, Santosh Kumar; Yadav, Pragya D.; Basu, Atanu; Chadha, Mandeep S.

    2017-01-01

    Background & objectives: Differential diagnosis of Crimean-Congo haemorrhagic fever (CCHF) from other acute febrile illnesses with haemorrhagic manifestation is challenging in India. Nosocomial infection is a significant mode of transmission due to exposure of healthcare workers to blood and body fluids of infected patients. Being a risk group 4 virus, laboratory confirmation of infection is not widely available. In such a situation, early identification of potential CCHF patients would be useful in limiting the spread of the disease. The objective of this study was to retrospectively analyse clinical and laboratory findings of CCHF patients that might be useful in early detection of a CCHF case in limited resource settings. Methods: Retrospective analysis of clinical and laboratory data of patients suspected to have CCHF referred for diagnosis from Gujarat and Rajasthan States of India (2014-2015) was done. Samples were tested using CCHF-specific real time reverse transcription (RT)-PCR and IgM ELISA. Results: Among the 69 patients referred, 21 were laboratory confirmed CCHF cases of whom nine had a history of occupational exposure. No clustering of cases was noted. Platelet count cut-off for detection of positive cases by receiver operating characteristic curve was 21.5×10[9]/l with sensitivity 82.4 per cent and specificity 82.1 per cent. Melaena was a significant clinical presentation in confirmed positive CCHF patients. Interpretation & conclusions: The study findings suggest that in endemic areas thrombocytopenia and melaena may be early indicators of CCHF. Further studies are needed to confirm these findings. PMID:28948959

  4. Real-time polymerase chain reaction and culture in the diagnosis of invasive group B streptococcal disease in infants: a retrospective study.

    PubMed

    Meehan, M; Cafferkey, M; Corcoran, S; Foran, A; Hapnes, N; LeBlanc, D; McGuinness, C; Nusgen, U; O'Sullivan, N; Cunney, R; Drew, R

    2015-12-01

    Group B streptococcus (GBS) is a leading cause of invasive disease in infants. Accurate and rapid diagnosis is crucial to reduce morbidity and mortality. Real-time polymerase chain reaction (PCR) targeting the dltR gene was utilised for the direct detection of GBS DNA in blood and cerebrospinal fluid (CSF) from infants at an Irish maternity hospital. A retrospective review of laboratory and patient records during the period 2011-2013 was performed in order to evaluate PCR and culture for the diagnosis of invasive GBS disease. A total of 3570 blood and 189 CSF samples from 3510 infants had corresponding culture and PCR results. Culture and PCR exhibited concordance in 3526 GBS-negative samples and 13 (25%) GBS-positive samples (n = 53). Six (11%) and 34 (64%) GBS-positive samples were positive only in culture or PCR, respectively. Culture and PCR identified more GBS-positive infants (n = 47) than PCR (n = 43) or culture (n = 16) alone. Using culture as the reference standard, the sensitivity, specificity, and positive and negative predictive values for PCR on blood samples were 71.4%, 99.2%, 25% and 99.9%, and for CSF samples, they were 60%, 97.8%, 42.9% and 98.9%, respectively. The sensitivity and positive predictive values were improved (blood: 84.6% and 55%; CSF: 77.8% and 100%, respectively) when maternal risk factors and other laboratory test results were considered. The findings in this study recommend the use of direct GBS real-time PCR for the diagnosis of GBS infection in infants with a clinical suspicion of invasive disease and as a complement to culture, but should be interpreted in the light of other laboratory and clinical findings.

  5. The Air Force's central reference laboratory: maximizing service while minimizing cost.

    PubMed

    Armbruster, D A

    1991-11-01

    The Laboratory Services Branch (Epi Lab) of the Epidemiology Division, Brooks AFB, Texas, is designated by regulation to serve as the Air Force's central reference laboratory, providing clinical laboratory testing support to all Air Force medical treatment facilities (MTFs). Epi Lab recognized that it was not offering the MTFs a service comparable to civilian reference laboratories and that, as a result, the Air Force medical system was spending hundreds of thousands of dollars yearly for commercial laboratory support. An in-house laboratory upgrade program was proposed to and approved by the USAF Surgeon General, as a Congressional Efficiencies Add project, to launch a two-phase initiative consisting of a 1-year field trial of 30 MTFs, followed by expansion to another 60 MTFs. Major components of the program include overnight air courier service to deliver patient samples to Epi Lab, a mainframe computer laboratory information system and electronic reporting of results to the MTFs throughout the CONUS. Application of medical marketing concepts and the Total Quality Management (TQM) philosophy allowed Epi to provide dramatically enhanced reference service at a cost savings of about $1 million to the medical system. The Epi Lab upgrade program represents an innovative problem-solving approach, combining technical and managerial improvements, resulting in substantial patient care service and financial dividends. It serves as an example of successful application of TQM and marketing within the military medical system.

  6. Bacterial and fungal components in house dust of farm children, Rudolf Steiner school children and reference children--the PARSIFAL Study.

    PubMed

    Schram, D; Doekes, G; Boeve, M; Douwes, J; Riedler, J; Ublagger, E; von Mutius, E; Budde, J; Pershagen, G; Nyberg, F; Alm, J; Braun-Fahrländer, C; Waser, M; Brunekreef, B

    2005-05-01

    Growing up on a farm and an anthroposophic lifestyle are associated with a lower prevalence of allergic diseases in childhood. It has been suggested that the enhanced exposure to endotoxin is an important protective factor of farm environments. Little is known about exposure to other microbial components on farms and exposure in anthroposophic families. To assess the levels and determinants of bacterial endotoxin, mould beta(1,3)-glucans and fungal extracellular polysaccharides (EPS) in house dust of farm children, Steiner school children and reference children. Mattress and living room dust was collected in the homes of 229 farm children, 122 Steiner children and 60 and 67 of their respective reference children in five European countries. Stable dust was collected as well. All samples were analysed in one central laboratory. Determinants were assessed by questionnaire. Levels of endotoxin, EPS and glucans per gram of house dust in farm homes were 1.2- to 3.2-fold higher than levels in reference homes. For Steiner children, 1.1- to 1.6-fold higher levels were observed compared with their reference children. These differences were consistently found across countries, although mean levels varied considerably. Differences between groups and between countries were also significant after adjustment for home and family characteristics. Farm children are not only consistently exposed to higher levels of endotoxin, but also to higher levels of mould components. Steiner school children may also be exposed to higher levels of microbial agents, but differences with reference children are much less pronounced than for farm children. Further analyses are, however, required to assess the association between exposure to these various microbial agents and allergic and airway diseases in the PARSIFAL population.

  7. Age and sex variation in serum albumin concentration: an observational study.

    PubMed

    Weaving, Gary; Batstone, Gifford F; Jones, Richard G

    2016-01-01

    In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.

  8. Quantitative comparison of DNA methylation assays for biomarker development and clinical applications.

    PubMed

    2016-07-01

    DNA methylation patterns are altered in numerous diseases and often correlate with clinically relevant information such as disease subtypes, prognosis and drug response. With suitable assays and after validation in large cohorts, such associations can be exploited for clinical diagnostics and personalized treatment decisions. Here we describe the results of a community-wide benchmarking study comparing the performance of all widely used methods for DNA methylation analysis that are compatible with routine clinical use. We shipped 32 reference samples to 18 laboratories in seven different countries. Researchers in those laboratories collectively contributed 21 locus-specific assays for an average of 27 predefined genomic regions, as well as six global assays. We evaluated assay sensitivity on low-input samples and assessed the assays' ability to discriminate between cell types. Good agreement was observed across all tested methods, with amplicon bisulfite sequencing and bisulfite pyrosequencing showing the best all-round performance. Our technology comparison can inform the selection, optimization and use of DNA methylation assays in large-scale validation studies, biomarker development and clinical diagnostics.

  9. Quality assurance and quality improvement in U.S. clinical molecular genetic laboratories.

    PubMed

    Chen, Bin; Richards, C Sue; Wilson, Jean Amos; Lyon, Elaine

    2011-04-01

    A robust quality-assurance program is essential for laboratories that perform molecular genetic testing to maintain high-quality testing and be able to address challenges associated with performance or delivery of testing services as the use of molecular genetic tests continues to expand in clinical and public health practice. This unit discusses quality-assurance and quality-improvement considerations that are critical for molecular genetic testing performed for heritable diseases and conditions. Specific discussion is provided on applying regulatory standards and best practices in establishing/verifying test performance, ensuring quality of the total testing process, monitoring and maintaining personnel competency, and continuing quality improvement. The unit provides a practical reference for laboratory professionals to use in recognizing and addressing essential quality-assurance issues in human molecular genetic testing. It should also provide useful information for genetics researchers, trainees, and fellows in human genetics training programs, as well as others who are interested in quality assurance and quality improvement for molecular genetic testing. 2011 by John Wiley & Sons, Inc.

  10. Principles and applications of flow cytometry and cell sorting in companion animal medicine.

    PubMed

    Wilkerson, Melinda J

    2012-01-01

    Flow cytometry measures multiple characteristic of single cells using light scatter properties and fluorescence properties of fluorescent probes with specificity to cellular constituents. The use of flow cytometry in the veterinary clinical laboratory has become more routine in veterinary diagnostic laboratories and institutions (http://www.vet.k-state.edu/depts/dmp/service/immunology/index.htm), and reference laboratories. The most common applications in small animal medicine includes quantitation of erythrocytes and leukocytes in automated hematology instruments, detection of antibodies to erythrocytes and platelets in cases of immune-mediated diseases, immunophenotyping of leukocytes and lymphocytes in immunodeficiency syndromes, or leukemias and lymphomas. DNA content analysis to identify aneuploidy or replicating cells in tumor preparations has not gained routine acceptance because of the variability of prognostic results. Other applications including cell sorting and multiplexing using microspheres are potential assays of the future once they become validated and the instrumentation footprint becomes more and more compact, less expensive, and easier to use.

  11. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).

  12. In vitro vaccine potency testing: a proposal for reducing animal use for requalification testing.

    PubMed

    Brown, K; Stokes, W

    2012-01-01

    This paper proposes a program under which the use of animals for requalification of in vitro potency tests could be eliminated. Standard References (USDA/CVB nomenclature) would be developed, characterized, stored and monitored by selected reference laboratories worldwide. These laboratories would employ scientists skilled in protein and glycoprotein chemistry and equipped with state-of-the-art instruments for required analyses. After Standard References are established, the reference laboratories would provide them to the animal health industry as "gold standards". Companies would then establish and validate a correlation between the Standard Reference and the company Master Reference (USDA/CVB nomenclature) using an internal in vitro assay. After this correlation is established, the company could use the Standard References for qualifying, monitoring and requalifying company Master References without the use of animals. Such a program would eliminate the need for animals for requalification of Master References and the need for each company to develop and validate a battery of Master Reference Monitoring assays. It would also provide advantages in terms of reduced costs and reduced time for requalification testing. As such it would provide a strong incentive for companies to develop and use in vitro assays for potency testing.

  13. [STUDYING GASTRIC ULCERATION EFFECT OF A NEW DRUG INTENDED FOR TREATMENT OF CHRONIC INFLAMMATORY DISEASES OF KIDNEYS AND URINARY TRACT.

    PubMed

    Murashko, T O; Smirnov, I V; Ivanov, A A; Postnikov, P S; Nemtsev, A O; Bondarev, A A; Udut, V V; Prisukhin, A N; Kornaukhov, A N; Sergeev, T S

    2016-08-01

    Gastric ulceration properties (gastrointestinal toxicity) of the sodium salt of 4-(0-β-D-glucopyranosyloxy) benzoic acid, a new nonsteroidal anti-inflammatory drug (NSAID) intended for the treatment of chronic inflammatory diseases of the kidney and urinary tract, have been tested on laboratory animals. Acute NSAID-induced gastropathy was induced in rats by oral administration of indomethacin, nimesulide, diclofenac, acetylsalicylic acid and the new drug. Test animals were killed by instantaneous decapitation 4 h after treatment and their gastrointestinal tracts were studied by pathomorphological methods on micropreparations and histological sections of gastric mucosa. It was established that the new drug, in contrast to reference NSAIDS, did not exhibit gastropathic action on the gastric mucosa.

  14. Manganese recycling in the United States in 1998

    USGS Publications Warehouse

    Jones, Thomas S.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  15. Hematology and Serum Biochemistry Reference Intervals for Six-Week-Old, Farm-Reared Chinese Ring-Necked Pheasants ( Phasianus colchicus ) from Minnesota.

    PubMed

    Dzikamunhenga, R S; Griffith, R W; Hostetter, S; Fisher, P; Larson, W

    2017-06-01

    Chinese ring-necked pheasants ( Phasianus colchicus ) are commonly farmed in intensive operations for purposes such as meat production, hunting preserves, or research. Under these conditions, pheasants frequently suffer medical ailments such as bacterial, viral, and parasitic infections or nutritional or metabolic disorders. Relatively little scientific information exists regarding clinical pathology reference intervals (RIs) for farm-reared pheasants. The objective of this study was to determine RIs for hematologic and serum biochemical variables for Chinese ring-necked pheasants from Minnesota at 6 wk of age. Blood samples from 119 clinically healthy Chinese ring-necked pheasants were analyzed using standard techniques. Reference intervals were generated in Microsoft® Excel® 2013 (Microsoft, Redmond, WA) using Reference Value Advisor freeware version 2.1 (Microsoft). Ninety-five percent RIs were determined using nonparametric methods that followed Clinical and Laboratory Standards Institute guidelines. These RIs will be useful for the monitoring of health and diagnosis of disease in confined Chinese ring-necked pheasant populations that are approximately 6 wk old.

  16. IAP Guidelines on Rickettsial Diseases in Children.

    PubMed

    Rathi, Narendra; Kulkarni, Atul; Yewale, Vijay

    2017-03-15

    To formulate practice guidelines on rickettsial diseases in children for pediatricians across India. Rickettsial diseases are increasingly being reported from various parts of India. Due to low index of suspicion, nonspecific clinical features in early course of disease, and absence of easily available, sensitive and specific diagnostic tests, these infections are difficult to diagnose. With timely diagnosis, therapy is easy, affordable and often successful. On the other hand, in endemic areas, where healthcare workers have high index of suspicion for these infections, there is rampant and irrational use of doxycycline as a therapeutic trial in patients of undifferentiated fevers. Thus, there is a need to formulate practice guidelines regarding rickettsial diseases in children in Indian context. A committee was formed for preparing guidelines on rickettsial diseases in children in June 2016. A meeting of consultative committee was held in IAP office, Mumbai and scientific content was discussed. Methodology and results were scrutinized by all members and consensus was reached. Textbook references and published guidelines were also used in few instances to make recommendations. Various Indian and international publications pertinent to present study were collated and guidelines were approved by all committee members. Future updates in these guidelines will be dictated by new scientific data in the field of rickettsial diseases in children. Indian tick typhus and scrub typhus are commonly seen rickettsial diseases in India. It is recommended that practicing pediatricians should be well conversant with compatible clinical scenario, suggestive epidemiological features, differential diagnoses and suggestive laboratory features to make diagnosis and avoid over diagnosis of these infections, as suggested in these guidelines. Doxycycline is the drug of choice and treatment should begin promptly without waiting for confirmatory laboratory results.

  17. Analysis of on-line clinical laboratory manuals and practical recommendations.

    PubMed

    Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron

    2004-04-01

    On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.

  18. [The requirements of standard and conditions of interchangeability of medical articles].

    PubMed

    Men'shikov, V V; Lukicheva, T I

    2013-11-01

    The article deals with possibility to apply specific approaches under evaluation of interchangeability of medical articles for laboratory analysis. The development of standardized analytical technologies of laboratory medicine and formulation of requirements of standards addressed to manufacturers of medical articles the clinically validated requirements are to be followed. These requirements include sensitivity and specificity of techniques, accuracy and precision of research results, stability of reagents' quality in particular conditions of their transportation and storage. The validity of requirements formulated in standards and addressed to manufacturers of medical articles can be proved using reference system, which includes master forms and standard samples, reference techniques and reference laboratories. This approach is supported by data of evaluation of testing systems for measurement of level of thyrotrophic hormone, thyroid hormones and glycated hemoglobin HB A1c. The versions of testing systems can be considered as interchangeable only in case of results corresponding to the results of reference technique and comparable with them. In case of absence of functioning reference system the possibilities of the Joined committee of traceability in laboratory medicine make it possible for manufacturers of reagent sets to apply the certified reference materials under development of manufacturing of sets for large listing of analytes.

  19. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  20. Refractory hypocalcaemia complicating metastatic prostatic carcinoma

    PubMed Central

    Rizzo, Christopher; Vella, Sandro; Cachia, Mario J

    2015-01-01

    A 72-year-old man with a background of ischaemic heart disease was referred to the accident and emergency department with a 1-week history of worsening dyspnoea and lethargy. A chest X-ray revealed a right-sided lobar pneumonia and a prolonged corrected QT interval was noted on his ECG at presentation. Laboratory investigations confirmed severe hypocalcaemia, significant vitamin D deficiency and relative hypoparathyroidism. A markedly elevated prostate-specific antigen was also identified. Bone scintigraphy demonstrated widespread osteoblastic bone metastases. Severe hypocalcaemia persisted despite treatment and he succumbed after 60 days of hospitalisation. PMID:26123464

  1. Biosafety: guidelines for working with pathogenic and infectious microorganisms.

    PubMed

    Coico, Richard; Lunn, George

    2005-11-01

    This unit, in conjunction with local and national guidelines and regulations, provides the basic biosafety information needed to perform the procedures detailed in this manual. Topics discussed include routine precautions when working with biohazards, disinfectants, disposal of biohazards, biosafety levels (as established by the U.S. National Institutes of Health, and the Centers for Disease Control and Prevention), animal facilities, and clinical laboratories. In addition, resources for more information are provided in the Literature Cited and Key References sections and in URLs given text and within the Internet Resources section.

  2. 42 CFR 493.1264 - Standard: Parasitology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1264 Standard: Parasitology. (a) The laboratory must have available a reference collection... these references in the laboratory for appropriate comparison with diagnostic specimens. (b) The...

  3. Expansion of Surveillance for Vaccine-preventable Diseases: Building on the Global Polio Laboratory Network and the Global Measles and Rubella Laboratory Network Platforms.

    PubMed

    Mulders, Mick N; Serhan, Fatima; Goodson, James L; Icenogle, Joseph; Johnson, Barbara W; Rota, Paul A

    2017-07-01

    Laboratory networks were established to provide accurate and timely laboratory confirmation of infections, an essential component of disease surveillance systems. The World Health Organization (WHO) coordinates global laboratory surveillance of vaccine-preventable diseases (VPDs), including polio, measles and rubella, yellow fever, Japanese encephalitis, rotavirus, and invasive bacterial diseases. In addition to providing high-quality laboratory surveillance data to help guide disease control, elimination, and eradication programs, these global networks provide capacity-building and an infrastructure for public health laboratories. There are major challenges with sustaining and expanding the global laboratory surveillance capacity: limited resources and the need for expansion to meet programmatic goals. Here, we describe the WHO-coordinated laboratory networks supporting VPD surveillance and present a plan for the further development of these networks. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  4. Surveillance of infectious diseases in the Arctic.

    PubMed

    Bruce, M; Zulz, T; Koch, A

    2016-08-01

    This study reviews how social and environmental issues affect health in Arctic populations and describes infectious disease surveillance in Arctic Nations with a special focus on the activities of the International Circumpolar Surveillance (ICS) project. We reviewed the literature over the past 2 decades looking at Arctic living conditions and their effects on health and Arctic surveillance for infectious diseases. In regards to other regions worldwide, the Arctic climate and environment are extreme. Arctic and sub-Arctic populations live in markedly different social and physical environments compared to those of their more southern dwelling counterparts. A cold northern climate means people spending more time indoors, amplifying the effects of household crowding, smoking and inadequate ventilation on the person-to-person spread of infectious diseases. The spread of zoonotic infections north as the climate warms, emergence of antibiotic resistance among bacterial pathogens, the re-emergence of tuberculosis, the entrance of HIV into Arctic communities, the specter of pandemic influenza or the sudden emergence and introduction of new viral pathogens pose new challenges to residents, governments and public health authorities of all Arctic countries. ICS is a network of hospitals, public health agencies, and reference laboratories throughout the Arctic working together for the purposes of collecting, comparing and sharing of uniform laboratory and epidemiological data on infectious diseases of concern and assisting in the formulation of prevention and control strategies (Fig. 1). In addition, circumpolar infectious disease research workgroups and sentinel surveillance systems for bacterial and viral pathogens exist. The ICS system is a successful example of collaborative surveillance and research in an extreme environment. Published by Elsevier Ltd.

  5. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples: T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents) and Hg-27 (Mercury) distributed in September 1998

    USGS Publications Warehouse

    Farrar, Jerry W.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples -- T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents), and Hg- 27 (mercury) -- which were distributed in September 1998 to 162 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  6. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1993 : T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for eight standard reference samples--T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)--that were distributed in October 1993 to 158 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 145 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the eight reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the eight standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  7. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1994 : T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength) and Hg-19 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1995-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 7 standard reference samples--T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength), and Hg-19 (mercury). The samples were distributed in October 1994 to 131 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 121 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  8. Bibliography of references to avian botulism: Update

    USGS Publications Warehouse

    Wilson, Sonoma S.; Locke, Louis N.

    1982-01-01

    This bibliography, first compiled in 1970 (Allen and Wilson 1977) and published in 1977 in response to many requests for information on avian botulism, has been updated to include the literature published through 1980.In general, only articles dealing primarily with the avian disease are included, as opposed to those concerned with the various aspects of the biology of Clostridium botulinum, either type C or E. A few exceptions, such as Bengtson's report of the first isolation and description of the type C organism, are included for their historical interest. Progress reports and other administrative documents not available for distribution on request are excluded, as are most textbook accounts, which are generally summaries of work published elsewhere.This bibliography was a cooperative effort by the National Wildlife Health Laboratory, U.S. Fish and Wildlife Service, and the U.S. National Park Service. The National Park Service provided partial funding for the work through Contract No. 89100-0491.Although the authors attempted to list every important reference, they make no claim to complete coverage of the published literature. The authors will be grateful to users of the bibliography who call attention to errors or omissions.Wayne I. Jensen (Retired)Milton Friend, Director, National Wildlife Health Laboratory

  9. Diagnostic tool for red blood cell membrane disorders: Assessment of a new generation ektacytometer☆

    PubMed Central

    Da Costa, Lydie; Suner, Ludovic; Galimand, Julie; Bonnel, Amandine; Pascreau, Tiffany; Couque, Nathalie; Fenneteau, Odile; Mohandas, Narla

    2016-01-01

    Inherited red blood cell (RBC) membrane disorders, such as hereditary spherocytosis, elliptocytosis and hereditary ovalocytosis, result from mutations in genes encoding various RBC membrane and skeletal proteins. The RBC membrane, a composite structure composed of a lipid bilayer linked to a spectrin/actin-based membrane skeleton, confers upon the RBC unique features of deformability and mechanical stability. The disease severity is primarily dependent on the extent of membrane surface area loss. RBC membrane disorders can be readily diagnosed by various laboratory approaches that include RBC cytology, flow cytometry, ektacytometry, electrophoresis of RBC membrane proteins and genetics. The reference technique for diagnosis of RBC membrane disorders is the osmotic gradient ektacytometry. However, in spite of its recognition as the reference technique, this technique is rarely used as a routine diagnosis tool for RBC membrane disorders due to its limited availability. This may soon change as a new generation of ektacytometer has been recently engineered. In this review, we describe the workflow of the samples shipped to our Hematology laboratory for RBC membrane disorder analysis and the data obtained for a large cohort of French patients presenting with RBC membrane disorders using a newly available version of the ektacytomer. PMID:26603718

  10. Validation of a high-throughput real-time polymerase chain reaction assay for the detection of capripoxviral DNA.

    PubMed

    Stubbs, Samuel; Oura, Chris A L; Henstock, Mark; Bowden, Timothy R; King, Donald P; Tuppurainen, Eeva S M

    2012-02-01

    Capripoxviruses, which are endemic in much of Africa and Asia, are the aetiological agents of economically devastating poxviral diseases in cattle, sheep and goats. The aim of this study was to validate a high-throughput real-time PCR assay for routine diagnostic use in a capripoxvirus reference laboratory. The performance of two previously published real-time PCR methods were compared using commercially available reagents including the amplification kits recommended in the original publication. Furthermore, both manual and robotic extraction methods used to prepare template nucleic acid were evaluated using samples collected from experimentally infected animals. The optimised assay had an analytical sensitivity of at least 63 target DNA copies per reaction, displayed a greater diagnostic sensitivity compared to conventional gel-based PCR, detected capripoxviruses isolated from outbreaks around the world and did not amplify DNA from related viruses in the genera Orthopoxvirus or Parapoxvirus. The high-throughput robotic DNA extraction procedure did not adversely affect the sensitivity of the assay compared to manual preparation of PCR templates. This laboratory-based assay provides a rapid and robust method to detect capripoxviruses following suspicion of disease in endemic or disease-free countries. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  11. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  12. The disease management approach to cost containment.

    PubMed

    Goldstein, R

    1998-01-01

    Disease management has been around a long time, certainly since Pasteur. Its initial focus was to eliminate or contain epidemics. In the 20th century, American public health scientists and officials have used disease management to address a high-risk, often poor population. Currently, the population-based principles of disease management, including disease prevention activities, are being applied to noninfectious diseases. Two examples of public health disease prevention strategies are vaccinations and chlorination of water. Hospitals are now providing post-hospital disease management programs for selected chronic conditions that account for a high volume of repeat admissions or emergency department visits, such as chronic heart failure, asthma, and cancer. In other words, hospitals are spending money on a program that, if done right, will reduce their inpatient revenues. They are doing so for various reasons (e.g., because they have established at-risk financial partnerships with their physicians, or possibly because other area hospitals are doing it, or possibly because they want to keep the ancillaries [x-rays, laboratory, pharmacy, ambulatory surgery, etc]). Regardless of the reasons, hospital case managers will be charged with referring qualified patients to both hospital-based and provider-based disease management programs.

  13. Development of a candidate reference material for adventitious virus detection in vaccine and biologicals manufacturing by deep sequencing

    PubMed Central

    Mee, Edward T.; Preston, Mark D.; Minor, Philip D.; Schepelmann, Silke; Huang, Xuening; Nguyen, Jenny; Wall, David; Hargrove, Stacey; Fu, Thomas; Xu, George; Li, Li; Cote, Colette; Delwart, Eric; Li, Linlin; Hewlett, Indira; Simonyan, Vahan; Ragupathy, Viswanath; Alin, Voskanian-Kordi; Mermod, Nicolas; Hill, Christiane; Ottenwälder, Birgit; Richter, Daniel C.; Tehrani, Arman; Jacqueline, Weber-Lehmann; Cassart, Jean-Pol; Letellier, Carine; Vandeputte, Olivier; Ruelle, Jean-Louis; Deyati, Avisek; La Neve, Fabio; Modena, Chiara; Mee, Edward; Schepelmann, Silke; Preston, Mark; Minor, Philip; Eloit, Marc; Muth, Erika; Lamamy, Arnaud; Jagorel, Florence; Cheval, Justine; Anscombe, Catherine; Misra, Raju; Wooldridge, David; Gharbia, Saheer; Rose, Graham; Ng, Siemon H.S.; Charlebois, Robert L.; Gisonni-Lex, Lucy; Mallet, Laurent; Dorange, Fabien; Chiu, Charles; Naccache, Samia; Kellam, Paul; van der Hoek, Lia; Cotten, Matt; Mitchell, Christine; Baier, Brian S.; Sun, Wenping; Malicki, Heather D.

    2016-01-01

    Background Unbiased deep sequencing offers the potential for improved adventitious virus screening in vaccines and biotherapeutics. Successful implementation of such assays will require appropriate control materials to confirm assay performance and sensitivity. Methods A common reference material containing 25 target viruses was produced and 16 laboratories were invited to process it using their preferred adventitious virus detection assay. Results Fifteen laboratories returned results, obtained using a wide range of wet-lab and informatics methods. Six of 25 target viruses were detected by all laboratories, with the remaining viruses detected by 4–14 laboratories. Six non-target viruses were detected by three or more laboratories. Conclusion The study demonstrated that a wide range of methods are currently used for adventitious virus detection screening in biological products by deep sequencing and that they can yield significantly different results. This underscores the need for common reference materials to ensure satisfactory assay performance and enable comparisons between laboratories. PMID:26709640

  14. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-01-01

    Introduction With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. Materials and methods In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Results Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Conclusions Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia. PMID:27812306

  15. Experimental Autoimmune Encephalomyelitis (EAE) as Animal Models of Multiple Sclerosis (MS).

    PubMed

    Glatigny, Simon; Bettelli, Estelle

    2018-01-08

    Multiple sclerosis (MS) is a multifocal demyelinating disease of the central nervous system (CNS) leading to the progressive destruction of the myelin sheath surrounding axons. It can present with variable clinical and pathological manifestations, which might reflect the involvement of distinct pathogenic processes. Although the mechanisms leading to the development of the disease are not fully understood, numerous evidences indicate that MS is an autoimmune disease, the initiation and progression of which are dependent on an autoimmune response against myelin antigens. In addition, genetic susceptibility and environmental triggers likely contribute to the initiation of the disease. At this time, there is no cure for MS, but several disease-modifying therapies (DMTs) are available to control and slow down disease progression. A good number of these DMTs were identified and tested using animal models of MS referred to as experimental autoimmune encephalomyelitis (EAE). In this review, we will recapitulate the characteristics of EAE models and discuss how they help shed light on MS pathogenesis and help test new treatments for MS patients. Copyright © 2018 Cold Spring Harbor Laboratory Press; all rights reserved.

  16. Chemical mutagenesis in laboratory mammals. A bibliography on the effects of chemicals on germ cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Von Halle, E.S.

    1973-09-01

    A list of references is presented on chemical mutagenesis in laboratory mammals. The references relate primarily to chemical effects on germ cells. Only references to the use of chemicals or chemicals and radiation are included. The publication includes a citation index, agent index, chemical abstracts registry number index, organism index, KWIC index, author index, and first author index. (ERB)

  17. Improved Specimen-Referral System and Increased Access to Quality Laboratory Services in Ethiopia: The Role of the Public-Private Partnership

    PubMed Central

    Kebede, Yenew; Fonjungo, Peter N.; Tibesso, Gudeta; Shrivastava, Ritu; Nkengasong, John N.; Kenyon, Thomas; Kebede, Amha; Gadde, Renuka; Ayana, Gonfa

    2016-01-01

    Background. Nonstandardized specimen-transport logistics, lack of laboratory personnel to transport specimens, lack of standard specimen containers, and long turnaround time (TAT) hindered access to quality laboratory services. The objective of the Becton, Dickinson, and Company (BD)–US President's Emergency Plan for AIDS Relief (PEPFAR) Public-Private Partnership (PPP) was to support country-specific programs to develop integrated laboratory systems, services, and quality improvement strategies, with an emphasis on strengthening the specimen-referral system (SRS). Methods. In 2007, through the Centers for Disease Control and Prevention (CDC), the Ethiopian Public Health Institute (EPHI) joined with the BD-PEPFAR PPP to strengthen laboratory systems. A joint planning and assessment committee identified gaps in the SRS for prioritization and intervention and piloted the system in Addis Ababa and Amhara Region. Results. The PPP established standardized, streamlined specimen logistics, using the Ethiopian Postal Service Enterprise to support a laboratory network in which 554 facilities referred specimens to 160 laboratories. The PPP supported procuring 400 standard specimen containers and the training of 586 laboratory personnel and 81 postal workers. The average TAT was reduced from 7 days (range, 2–14 days) to 2 days (range, 1–3 days) in Addis Ababa and from 10 days (range, 6–21 days) to 5 days (range, 2–6 days) in Amhara Region. Conclusions. This study highlights the feasibility and untapped potential of PPPs to strengthen laboratory systems. This planned and structured approach to improving specimen referral enhanced access to quality laboratory services. PMID:27025700

  18. How Do Experienced Physicians Access and Evaluate Laboratory Test Results for the Chronic Patient? A Qualitative Analysis.

    PubMed

    Torsvik, Torbjørn; Lillebo, Børge; Hertzum, Morten

    2018-04-01

     Electronic health records may present laboratory test results in a variety of ways. Little is known about how the usefulness of different visualizations of laboratory test results is influenced by the complex and varied process of clinical decision making.  The purpose of this study was to investigate how clinicians access and utilize laboratory test results when caring for patients with chronic illness.  We interviewed 10 attending physicians about how they access and assess laboratory tests when following up patients with chronic illness. The interviews were audio-recorded, transcribed verbatim, and analyzed qualitatively.  Informants preferred different visualizations of laboratory test results, depending on what aspects of the data they were interested in. As chronic patients may have laboratory test results that are permanently outside standardized reference ranges, informants would often look for significant change, rather than exact values. What constituted significant change depended on contextual information (e.g., the results of other investigations, intercurrent diseases, and medical interventions) spread across multiple locations in the electronic health record. For chronic patients, the temporal relations between data could often be of special interest. Informants struggled with finding and synthesizing fragmented information into meaningful overviews.  The presentation of laboratory test results should account for the large variety of associated contextual information needed for clinical comprehension. Future research is needed to improve the integration of the different parts of the electronic health record. Schattauer GmbH Stuttgart.

  19. Hand-arm vibration syndrome: What family physicians should know.

    PubMed

    Shen, Shixin Cindy; House, Ronald A

    2017-03-01

    To provide family physicians with an understanding of the epidemiology, pathogenesis, symptoms, diagnosis, and management of hand-arm vibration syndrome (HAVS), an important and common occupational disease in Canada. A MEDLINE search was conducted for research and review articles on HAVS. A Google search was conducted to obtain gray literature relevant to the Canadian context. Additional references were obtained from the articles identified. Hand-arm vibration syndrome is a prevalent occupational disease affecting workers in multiple industries in which vibrating tools are used. However, it is underdiagnosed in Canada. It has 3 components-vascular, in the form of secondary Raynaud phenomenon; sensorineural; and musculoskeletal. Hand-arm vibration syndrome in its more advanced stages contributes to substantial disability and poor quality of life. Its diagnosis requires careful history taking, in particular occupational history, physical examination, laboratory tests to rule out alternative diagnoses, and referral to an occupational medicine specialist for additional investigations. Management involves reduction of vibration exposure, avoidance of cold conditions, smoking cessation, and medication. To ensure timely diagnosis of HAVS and improve prognosis and quality of life, family physicians should be aware of this common occupational disease and be able to elicit the relevant occupational history, refer patients to occupational medicine clinics, and appropriately initiate compensation claims. Copyright© the College of Family Physicians of Canada.

  20. [Laboratory accreditation and proficiency testing].

    PubMed

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  1. Dominance of international 'high-risk clones' among metallo-β-lactamase-producing Pseudomonas aeruginosa in the UK.

    PubMed

    Wright, Laura L; Turton, Jane F; Livermore, David M; Hopkins, Katie L; Woodford, Neil

    2015-01-01

    Carbapenem-resistant isolates of Pseudomonas aeruginosa producing metallo-β-lactamases (MBLs) are increasingly reported worldwide and often belong to particular 'high-risk clones'. This study aimed to characterize a comprehensive collection of MBL-producing P. aeruginosa isolates referred to the UK national reference laboratory from multiple UK laboratories over a 10 year period. Isolates were referred to the UK national reference laboratory between 2003 and 2012 for investigation of resistance mechanisms and/or outbreaks. MBL genes were detected by PCR. Typing was carried out by nine-locus variable-number tandem repeat (VNTR) analysis and MLST. MBL-producing P. aeruginosa isolates were referred from 267 source patients and 89 UK laboratories. The most common isolation sites were urine (24%), respiratory (18%), wounds (17%) and blood (13%). VIM-type MBLs predominated (91% of all MBLs found), but a few IMP- and NDM-type enzymes were also identified. Diverse VNTR types were seen, but 86% of isolates belonged to six major complexes. MLST of representative isolates from each complex showed that they corresponded to STs 111, 233, 235, 357, 654 and 773, respectively. Isolates belonging to these complexes were received from between 9 and 25 UK referring laboratories each. The incidence of MBL-producing P. aeruginosa is increasing in the UK. The majority of these isolates belong to several 'high-risk clones', which have been previously reported internationally as host clones of MBLs. © Crown copyright 2014.

  2. Multicomponent blood lipid analysis by means of near infrared spectroscopy, in geese.

    PubMed

    Bazar, George; Eles, Viktoria; Kovacs, Zoltan; Romvari, Robert; Szabo, Andras

    2016-08-01

    This study provides accurate near infrared (NIR) spectroscopic models on some laboratory determined clinicochemical parameters (i.e. total lipid (5.57±1.95 g/l), triglyceride (2.59±1.36 mmol/l), total cholesterol (3.81±0.68 mmol/l), high density lipoprotein (HDL) cholesterol (2.45±0.58 mmol/l)) of blood serum samples of fattened geese. To increase the performance of multivariate chemometrics, samples significantly deviating from the regression models implying laboratory error were excluded from the final calibration datasets. Reference data of excluded samples having outlier spectra in principal component analysis were not marked as false. Samples deviating from the regression models but having non outlier spectra in PCA were identified as having false reference constituent values. Based on the NIR selection methods, 5% of the reference measurement data were rated as doubtful. The achieved models reached R(2) of 0.864, 0.966, 0.850, 0.793, and RMSE of 0.639 g/l, 0.232 mmol/l, 0.210 mmol/l, 0.241 mmol/l for total lipid, triglyceride, total cholesterol and HDL cholesterol, respectively, during independent validation. Classical analytical techniques focus on single constituents and often require chemicals, time-consuming measurements, and experienced technicians. NIR technique provides a quick, cost effective, non-hazardous alternative method for analysis of several constituents based on one single spectrum of each sample, and it also offers the possibility for looking at the laboratory reference data critically. Evaluation of reference data to identify and exclude falsely analyzed samples can provide warning feedback to the reference laboratory, especially in the case of analyses where laboratory methods are not perfectly suited to the subjected material and there is an increased chance of laboratory error. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. [Useful web sites for information about the recommendations of good practices in laboratory medicine].

    PubMed

    Szymanowicz, A; Watine, J

    2010-12-01

    In this paper are presented some useful web sites to find updated reference tables concerning the recommendations of professional practices in laboratory medicine. The knowledge of these reference tables can allow the biologist to develop its role of advice to the clinicians. It can also help him to assure a relevant interpretation of the laboratory results and to value the interest for the patient.

  4. Validity of administrative data claim-based methods for identifying individuals with diabetes at a population level.

    PubMed

    Southern, Danielle A; Roberts, Barbara; Edwards, Alun; Dean, Stafford; Norton, Peter; Svenson, Lawrence W; Larsen, Erik; Sargious, Peter; Lau, David C W; Ghali, William A

    2010-01-01

    This study assessed the validity of a widely-accepted administrative data surveillance methodology for identifying individuals with diabetes relative to three laboratory data reference standard definitions for diabetes. We used a combination of linked regional data (hospital discharge abstracts and physician data) and laboratory data to test the validity of administrative data surveillance definitions for diabetes relative to a laboratory data reference standard. The administrative discharge data methodology includes two definitions for diabetes: a strict administrative data definition of one hospitalization code or two physician claims indicating diabetes; and a more liberal definition of one hospitalization code or a single physician claim. The laboratory data, meanwhile, produced three reference standard definitions based on glucose levels +/- HbA1c levels. Sensitivities ranged from 68.4% to 86.9% for the administrative data definitions tested relative to the three laboratory data reference standards. Sensitivities were higher for the more liberal administrative data definition. Positive predictive values (PPV), meanwhile, ranged from 53.0% to 88.3%, with the liberal administrative data definition producing lower PPVs. These findings demonstrate the trade-offs of sensitivity and PPV for selecting diabetes surveillance definitions. Centralized laboratory data may be of value to future surveillance initiatives that use combined data sources to optimize case detection.

  5. Next-Generation Sequencing for Infectious Disease Diagnosis and Management: A Report of the Association for Molecular Pathology.

    PubMed

    Lefterova, Martina I; Suarez, Carlos J; Banaei, Niaz; Pinsky, Benjamin A

    2015-11-01

    Next-generation sequencing (NGS) technologies are increasingly being used for diagnosis and monitoring of infectious diseases. Herein, we review the application of NGS in clinical microbiology, focusing on genotypic resistance testing, direct detection of unknown disease-associated pathogens in clinical specimens, investigation of microbial population diversity in the human host, and strain typing. We have organized the review into three main sections: i) applications in clinical virology, ii) applications in clinical bacteriology, mycobacteriology, and mycology, and iii) validation, quality control, and maintenance of proficiency. Although NGS holds enormous promise for clinical infectious disease testing, many challenges remain, including automation, standardizing technical protocols and bioinformatics pipelines, improving reference databases, establishing proficiency testing and quality control measures, and reducing cost and turnaround time, all of which would be necessary for widespread adoption of NGS in clinical microbiology laboratories. Copyright © 2015 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  6. Prenatal molecular diagnosis of inherited neuromuscular diseases: Duchenne/Becker muscular dystrophy, myotonic dystrophy type 1 and spinal muscular atrophy.

    PubMed

    Esposito, Gabriella; Ruggiero, Raffaella; Savarese, Maria; Savarese, Giovanni; Tremolaterra, Maria Roberta; Salvatore, Francesco; Carsana, Antonella

    2013-12-01

    Neuromuscular disease is a broad term that encompasses many diseases that either directly, via an intrinsic muscle disorder, or indirectly, via a nerve disorder, impairs muscle function. Here we report the experience of our group in the counselling and molecular prenatal diagnosis of three inherited neuromuscular diseases, i.e., Duchenne/Becker muscular dystrophy (DMD/BMD), myotonic dystrophy type 1 (DM1), spinal muscular atrophy (SMA). We performed a total of 83 DMD/BMD, 15 DM1 and 54 SMA prenatal diagnoses using a combination of technologies for either direct or linkage diagnosis. We identified 16, 5 and 10 affected foetuses, respectively. The improvement of analytical procedures in recent years has increased the mutation detection rate and reduced the analytical time. Due to the complexity of the experimental procedures and the high, specific professional expertise required for both laboratory activities and the related counselling, these types of analyses should be preferentially performed in reference molecular diagnostic centres.

  7. TESTING PRACTICES AND VOLUME OF NON-LYME TICKBORNE DISEASES IN THE UNITED STATES

    PubMed Central

    Connally, Neeta P.; Hinckley, Alison F.; Feldman, Katherine A.; Kemperman, Melissa; Neitzel, David; Wee, Siok-Bi; White, Jennifer L.; Mead, Paul S.; Meek, James I.

    2015-01-01

    Large commercial laboratories in the United States were surveyed regarding the number of specimens tested for eight tickborne diseases in 2008. Seven large commercial laboratories reported testing a total of 2,927,881 specimens nationally (including Lyme disease). Of these, 495,585 specimens (17 percent) were tested for tickborne diseases other than Lyme disease. In addition to large commercial laboratories, another 1,051 smaller commercial, hospital, and government laboratories in four states (CT, MD, MN, and NY) were surveyed regarding tickborne disease testing frequency, practices, and results. Ninety-two of these reported testing a total of 10,091 specimens for four tickborne diseases other than Lyme disease. We estimate the cost of laboratory diagnostic testing for non-Lyme disease tickborne diseases in 2008 to be $9.6 million. These data provide a baseline to evaluate trends in tickborne disease test utilization and insight into the burden of these diseases. PMID:26565931

  8. Isotope reference materials

    USGS Publications Warehouse

    Coplen, Tyler B.

    2010-01-01

    Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.

  9. Animal welfare and the refinement of neuroscience research methods--a case study of Huntington's disease models.

    PubMed

    Olsson, I Anna S; Hansen, Axel K; Sandøe, Peter

    2008-07-01

    The use of animals in biomedical and other research presents an ethical dilemma: we do not want to lose scientific benefits, nor do we want to cause laboratory animals to suffer. Scientists often refer to the potential human benefits of animal models to justify their use. However, even if this is accepted, it still needs to be argued that the same benefits could not have been achieved with a mitigated impact on animal welfare. Reducing the adverse effects of scientific protocols ('refinement') is therefore crucial in animal-based research. It is especially important that researchers share knowledge on how to avoid causing unnecessary suffering. We have previously demonstrated that even in studies in which animal use leads to spontaneous death, scientists often fail to report measures to minimize animal distress (Olsson et al. 2007). In this paper, we present the full results of a case study examining reports, published in peer-reviewed journals between 2003 and 2004, of experiments employing animal models to study the neurodegenerative disorder Huntington's disease. In 51 references, experiments in which animals were expected to develop motor deficits so severe that they would have difficulty eating and drinking normally were conducted, yet only three references were made to housing adaptation to facilitate food and water intake. Experiments including end-stages of the disease were reported in 14 papers, yet of these only six referred to the euthanasia of moribund animals. If the reference in scientific publications reflects the actual application of refinement, researchers do not follow the 3Rs (replacement, reduction, refinement) principle. While in some cases, it is clear that less-than-optimal techniques were used, we recognize that scientists may apply refinement without referring to it; however, if they do not include such information in publications, it suggests they find it less relevant. Journal publishing policy could play an important role: first, in ensuring that referees seriously consider whether submitted studies were indeed carried out with the smallest achievable negative impact on the animals and, secondly, in encouraging scientists to share refinements through the inclusion of a 3Rs section in papers publishing the results of animal-based research.

  10. Imported malaria to Northern Ireland: improving surveillance for better intervention

    PubMed Central

    Ong, GM; Smyth, B

    2006-01-01

    Malaria is a preventable disease, which is under notified in the UK. This study sought to evaluate the current surveillance arrangements in Northern Ireland (NI), describe the epidemiology of malaria and make appropriate recommendations. A case was defined as a resident or visitor to NI with laboratory confirmed malaria, diagnosed by the NI haematology laboratories and/or the Malaria Reference Laboratory (MRL) from 1998–2003. Laboratory data were compared with notifications and hospital admission data. One hundred and fourteen laboratory cases were identified compared with 63 notifications received by the regional surveillance centre. Six cases were associated with two episodes of malaria reflecting recurrence and or reinfection. P. falciparum was the most common infection with two fatalities reported; this was particularly associated with travel to West Africa. Most cases were associated with short visits to malarious areas. Thirty-three percent of all cases did not take prophylaxis and, of those that did, approximately half were taking a prophylactic regime appropriate to the region visited. This study highlights the need for improved surveillance of malaria in order to capture risk factors and other relevant information to inform public and professional education. This would facilitate increasing local awareness, enhancing prescription of and compliance with appropriate chemoprophylaxis and enabling early diagnosis and treatment of malaria. PMID:16755943

  11. Standardized protocols for quality control of MRM-based plasma proteomic workflows.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H

    2013-01-04

    Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.

  12. DNA-Based Methods in the Immunohematology Reference Laboratory

    PubMed Central

    Denomme, Gregory A

    2010-01-01

    Although hemagglutination serves the immunohematology reference laboratory well, when used alone, it has limited capability to resolve complex problems. This overview discusses how molecular approaches can be used in the immunohematology reference laboratory. In order to apply molecular approaches to immunohematology, knowledge of genes, DNA-based methods, and the molecular bases of blood groups are required. When applied correctly, DNA-based methods can predict blood groups to resolve ABO/Rh discrepancies, identify variant alleles, and screen donors for antigen-negative units. DNA-based testing in immunohematology is a valuable tool used to resolve blood group incompatibilities and to support patients in their transfusion needs. PMID:21257350

  13. Results of an inter and intra laboratory exercise on the assessment of complex autosomal DNA profiles.

    PubMed

    Benschop, Corina C G; Connolly, Edward; Ansell, Ricky; Kokshoorn, Bas

    2017-01-01

    The interpretation of complex DNA profiles may differ between laboratories and reporting officers, which can lead to discrepancies in the final reports. In this study, we assessed the intra and inter laboratory variation in DNA mixture interpretation for three European ISO17025-accredited laboratories. To this aim, 26 reporting officers analyzed five sets of DNA profiles. Three main aspects were considered: 1) whether the mixed DNA profiles met the criteria for comparison to a reference profile, 2) the actual result of the comparison between references and DNA profiling data and 3) whether the weight of the DNA evidence could be assessed. Similarity in answers depended mostly on the complexity of the tasks. This study showed less variation within laboratories than between laboratories which could be the result of differences between internal laboratory guidelines and methods and tools available. Results show the profile types for which the three laboratories report differently, which informs indirectly on the complexity threshold the laboratories employ. Largest differences between laboratories were caused by the methods available to assess the weight of the DNA evidence. This exercise aids in training forensic scientists, refining laboratory guidelines and explaining differences between laboratories in court. Undertaking more collaborative exercises in future may stimulate dialog and consensus regarding interpretation. For training purposes, DNA profiles of the mixed stains and questioned references are made available. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Analytical characterization and clinical evaluation of an enzyme-linked immunosorbent assay for measurement of afamin in human plasma.

    PubMed

    Dieplinger, Benjamin; Egger, Margot; Gabriel, Christian; Poelz, Werner; Morandell, Elisabeth; Seeber, Beata; Kronenberg, Florian; Haltmayer, Meinhard; Mueller, Thomas; Dieplinger, Hans

    2013-10-21

    Comparative proteomics has recently identified afamin, the newest member of the albumin gene family, as a potential biomarker for ovarian cancer. The aim of this study was the analytical and clinical evaluation of a sandwich enzyme-linked immunosorbent assay for the determination of afamin in human plasma. We evaluated precision, linearity, and detection limit of the assay, analyte stability and biological variability, determined reference values and quantified afamin concentrations in various diseases. Within-run and total coefficients of variation were <10%. The method was linear across the tested measurement range. Detection limit was 7 mg/L for the assay. The analyte was stable for 24 h at room temperature, for 48 h at 4°C, and for at least one year at -20°C and -80°C. The reference change value for healthy individuals was 24%. Age- and sex-independent reference values in healthy blood donors were 45-99 mg/L (median 68 mg/L). In the clinical assay evaluation afamin plasma concentrations were modestly decreased in patients with heart failure. Patients with pneumonia or sepsis exhibited markedly decreased afamin plasma concentrations. However, patients with chronic renal disease or chronic obstructive pulmonary disease showed no difference in afamin plasma concentrations as compared to healthy individuals. Correlation analyses revealed an inverse association between afamin and inflammatory biomarkers. The afamin assay meets quality specifications for laboratory medicine. The results of the clinical assay evaluation revealed novel insights with respect to afamin as a potential negative acute phase protein and should encourage further studies. © 2013.

  15. Adult Hematology and Clinical Chemistry Laboratory Reference Ranges in a Zimbabwean Population.

    PubMed

    Samaneka, Wadzanai P; Mandozana, Gibson; Tinago, Willard; Nhando, Nehemiah; Mgodi, Nyaradzo M; Bwakura-Dangarembizi, Mutsawashe F; Munjoma, Marshall W; Gomo, Zvenyika A R; Chirenje, Zvavahera M; Hakim, James G

    2016-01-01

    Laboratory reference ranges used for clinical care and clinical trials in various laboratories in Zimbabwe were derived from textbooks and research studies conducted more than ten years ago. Periodic verification of these ranges is essential to track changes over time. The purpose of this study was to establish hematology and chemistry laboratory reference ranges using more rigorous methods. A community-based cross-sectional study was carried out in Harare, Chitungwiza, and Mutoko. A multistage sampling technique was used. Samples were transported from the field for analysis at the ISO15189 certified University of Zimbabwe-University of California San Francisco Central Research Laboratory. Hematology and clinical chemistry reference ranges lower and upper reference limits were estimated at the 2.5th and 97.5th percentiles respectively. A total of 769 adults (54% males) aged 18 to 55 years were included in the analysis. Median age was 28 [IQR: 23-35] years. Males had significantly higher red cell counts, hemoglobin, hematocrit, and mean corpuscular hemoglobin compared to females. Females had higher white cell counts, platelets, absolute neutrophil counts, and absolute lymphocyte counts compared to males. There were no gender differences in eosinophils, monocytes, and absolute basophil count. Males had significantly higher levels of urea, sodium, potassium, calcium, creatinine, amylase, total protein, albumin and liver enzymes levels compared to females. Females had higher cholesterol and lipase compared with males. There are notable differences in the white cell counts, neutrophils, cholesterol, and creatinine kinase when compared with the currently used reference ranges. Data from this study provides new country specific reference ranges which should be immediately adopted for routine clinical care and accurate monitoring of adverse events in research studies.

  16. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... All approved material incorporated by reference may be inspected at the National Archives and Records... Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington...: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research Triangle Park, NC...

  18. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... All approved material incorporated by reference may be inspected at the National Archives and Records... Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE., Washington...: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research Triangle Park, NC...

  19. Extensively Drug-Resistant Tuberculosis (XDR TB)

    MedlinePlus

    ... TB Reference Laboratory Network, the National TB Surveillance System in the United States, the national reference laboratory of South Korea, and ... capacity in the U.S. and abroad; and Developing education, risk, and media communications ... – United States, 1993–2006 CDC. CDC’s Role in Preventing XDR ...

  20. [Advance in studies on food allergy mechanism based on gut barrier].

    PubMed

    Wang, Juan-hong; Li, Huan-zhou; Li, Meng; Pan, Su-hua

    2015-04-01

    Food allergies, as a type of adverse immune-mediated reactions to ingested food proteins, have become a serious public health issue that harms children and adults health, with increasing incidence year by year. However, without effective therapy for food allergies, doctors-have mostly advised to avoid allergens and provided symptomatic treatment. According to the findings of many studies, allergic diseases are correlated with intestinal barrier function injury, as evidenced by the significant increase in the intestinal permeability among patients with food allergies. In this paper, recent studies on correlations between food allergies and intestinal barrier functions, intestinal barrier function injury mechanisms of allergic foods and food allergy intervention strategies based on intestinal barrier functions were summarized to provide reference for laboratory researches and clinical treatment of food allergic diseases.

  1. Treatment of end-stage renal disease with continuous ambulatory peritoneal dialysis in rural Guatemala

    PubMed Central

    Moore, Jillian; Garcia, Pablo; Flood, David

    2018-01-01

    A 42-year-old indigenous Maya man presented to a non-profit clinic in rural Guatemala with signs, symptoms and laboratory values consistent with uncontrolled diabetes. Despite appropriate treatment, approximately 18 months after presentation, he was found to have irreversible end-stage renal disease (ESRD) of uncertain aetiology. He was referred to the national public nephrology clinic and subsequently initiated home-based continuous ambulatory peritoneal dialysis. With primary care provided by the non-profit clinic, his clinical status improved on dialysis, but socioeconomic and psychological challenges persisted for the patient and his family. This case shows how care for people with ESRD in low- and middle-income countries requires scaling up renal replacement therapy and ensuring access to primary care, mental healthcare and social work services. PMID:29705734

  2. European Proficiency testing of national reference laboratories for the confirmation of sulfonamide residues in muscle and milk.

    PubMed

    Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal

    2005-03-01

    Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.

  3. The capacity of diagnostic laboratories in Kenya for detecting infectious diseases.

    PubMed

    Slotved, H-C; Yatich, Kennedy K; Sam, Shem Otoi; Ndhine, Edwardina Otieno

    2017-01-01

    The aim of this study is to present data of the diagnostic capacity of Kenyan laboratories to diagnose a number of human pathogens. The study is based on the data obtained from a biosecurity survey conducted in Kenya in 2014/2015 and data from the Statistical Abstract of Kenya for 2015. The biosecurity survey has previously been published; however, the survey also included information on laboratory capacity to handle a number of pathogens, which have not been published. Data were retrieved from the survey on 86 laboratory facilities. The data include information from relevant categories such as training laboratories, human diagnostic laboratories, veterinary diagnostic laboratories, and research laboratories. The disease incidence in Kenya ranges widely from malaria and diarrhea with an incidence rate of around 10.000 per year to diseases such as cholera and yellow fever with an incidence rate of 1 per year or less for all age groups. The data showed that diseases with the highest number of diagnostic facilities were mainly malaria-, HIV-, tuberculosis-, and diarrhea-related infectious diseases. The study generally shows that the laboratory facilities have the capacity of detecting the infectious diseases with the highest incidence rates. Furthermore, it seems that the number of facilities able to detect a particular disease is related to the incidence rate of the disease.

  4. Evaluation of positive Rift Valley fever virus formalin-fixed paraffin embedded samples as a source of sequence data for retrospective phylogenetic analysis.

    PubMed

    Mubemba, B; Thompson, P N; Odendaal, L; Coetzee, P; Venter, E H

    2017-05-01

    Rift Valley fever (RVF), caused by an arthropod borne Phlebovirus in the family Bunyaviridae, is a haemorrhagic disease that affects ruminants and humans. Due to the zoonotic nature of the virus, a biosafety level 3 laboratory is required for isolation of the virus. Fresh and frozen samples are the preferred sample type for isolation and acquisition of sequence data. However, these samples are scarce in addition to posing a health risk to laboratory personnel. Archived formalin-fixed, paraffin-embedded (FFPE) tissue samples are safe and readily available, however FFPE derived RNA is in most cases degraded and cross-linked in peptide bonds and it is unknown whether the sample type would be suitable as reference material for retrospective phylogenetic studies. A RT-PCR assay targeting a 490 nt portion of the structural G N glycoprotein encoding gene of the RVFV M-segment was applied to total RNA extracted from archived RVFV positive FFPE samples. Several attempts to obtain target amplicons were unsuccessful. FFPE samples were then analysed using next generation sequencing (NGS), i.e. Truseq ® (Illumina) and sequenced on the Miseq ® genome analyser (Illumina). Using reference mapping, gapped virus sequence data of varying degrees of shallow depth was aligned to a reference sequence. However, the NGS did not yield long enough contigs that consistently covered the same genome regions in all samples to allow phylogenetic analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Vipie: web pipeline for parallel characterization of viral populations from multiple NGS samples.

    PubMed

    Lin, Jake; Kramna, Lenka; Autio, Reija; Hyöty, Heikki; Nykter, Matti; Cinek, Ondrej

    2017-05-15

    Next generation sequencing (NGS) technology allows laboratories to investigate virome composition in clinical and environmental samples in a culture-independent way. There is a need for bioinformatic tools capable of parallel processing of virome sequencing data by exactly identical methods: this is especially important in studies of multifactorial diseases, or in parallel comparison of laboratory protocols. We have developed a web-based application allowing direct upload of sequences from multiple virome samples using custom parameters. The samples are then processed in parallel using an identical protocol, and can be easily reanalyzed. The pipeline performs de-novo assembly, taxonomic classification of viruses as well as sample analyses based on user-defined grouping categories. Tables of virus abundance are produced from cross-validation by remapping the sequencing reads to a union of all observed reference viruses. In addition, read sets and reports are created after processing unmapped reads against known human and bacterial ribosome references. Secured interactive results are dynamically plotted with population and diversity charts, clustered heatmaps and a sortable and searchable abundance table. The Vipie web application is a unique tool for multi-sample metagenomic analysis of viral data, producing searchable hits tables, interactive population maps, alpha diversity measures and clustered heatmaps that are grouped in applicable custom sample categories. Known references such as human genome and bacterial ribosomal genes are optionally removed from unmapped ('dark matter') reads. Secured results are accessible and shareable on modern browsers. Vipie is a freely available web-based tool whose code is open source.

  6. Use, location, and timeliness of clinical microbiology testing in Georgia for select infectious diseases.

    PubMed

    Brzozowski, Amanda K; Silk, Benjamin J; Berkelman, Ruth L; Loveys, Deborah A; Caliendo, Angela M

    2012-01-01

    Although clinical microbiology testing facilitates both public health surveillance of infectious diseases and patient care, research on testing patterns is scant. We surveyed hospital laboratories in Georgia to assess their diagnostic testing practices. Using e-mail, all directors of hospital laboratories in Georgia were invited to participate. The survey focused on timing and location of diagnostic testing in 2006 for 6 reportable diseases: giardiasis, legionellosis, meningococcal disease, pertussis, Rocky Mountain spotted fever, and West Nile virus disease. Of 141 laboratories, 62 (44%) responded to the survey. Hospitals varied widely in their use of diagnostic testing in 2006, with 95.1% testing for meningococcal disease, but only 66.1% and 63.3% testing for legionellosis and West Nile virus disease, respectively. Most laboratories (91%) performed gram stain/culture to diagnose meningococcal disease in-house and 23% performed ova and parasite panels for giardiasis were conducted in-house. Fewer than 11% of laboratories performed in-house testing for the remaining diseases. Laboratories affiliated with small hospitals (≤100 beds) were more likely to send specimens for outside testing compared with laboratories associated with large hospitals (>250 beds). Median turnaround time for ova and parasite panel testing for giardiasis was significantly shorter for in-house testing (1.0 days) than within-system (2.25 days) or outside laboratory (3.0 days) testing (P = .0003). No laboratories reported in-house testing for meningococcal disease, pertussis, or Rocky Mountain spotted fever using polymerase chain reaction. Many hospitals did not order diagnostic tests for important infectious diseases during 2006, even for relatively common diseases. In addition, hospital laboratories were unlikely to perform diagnostic testing in-house; sending specimens to an outside laboratory may result in substantial delays in receiving results. These unsettling findings have adverse implications for both patient care and public health surveillance; they indicate an immediate need to study nationally the use and timeliness of clinical microbiologic testing.

  7. Medical Services: Veterinary/Medical Food Inspection and Laboratory Service

    DTIC Science & Technology

    1997-11-06

    cosmetics. (2) Laboratory diagnosis of communicable and zoonotic diseases and conditions of military interest. (3) Management of laboratory animal...veterinary food inspection service. (b) Prevention and control of communicable diseases of animals and zoonotic diseases and conditions. (c...Development of command zoonotic disease control programs. (2) Advise the MACOM of sanitary defects or epizootics that may be detected through the laboratory

  8. Recovery of viral RNA and infectious foot-and-mouth disease virus from positive lateral-flow devices.

    PubMed

    Fowler, Veronica L; Bankowski, Bartlomiej M; Armson, Bryony; Di Nardo, Antonello; Valdazo-Gonzalez, Begoña; Reid, Scott M; Barnett, Paul V; Wadsworth, Jemma; Ferris, Nigel P; Mioulet, Valérie; King, Donald P

    2014-01-01

    Foot-and-mouth disease Virus (FMDV) is an economically important, highly contagious picornavirus that affects both wild and domesticated cloven hooved animals. In developing countries, the effective laboratory diagnosis of foot-and-mouth disease (FMD) is often hindered by inadequate sample preservation due to difficulties in the transportation and storage of clinical material. These factors can compromise the ability to detect and characterise FMD virus in countries where the disease is endemic. Furthermore, the high cost of sending infectious virus material and the biosecurity risk it presents emphasises the need for a thermo-stable, non-infectious mode of transporting diagnostic samples. This paper investigates the potential of using FMDV lateral-flow devices (LFDs) for dry transportation of clinical samples for subsequent nucleic acid amplification, sequencing and recovery of infectious virus by electroporation. FMDV positive samples (epithelial suspensions and cell culture isolates) representing four FMDV serotypes were applied to antigen LFDs: after which it was possible to recover viral RNA that could be detected using real-time RT-PCR. Using this nucleic acid, it was also possible to recover VP1 sequences and also successfully utilise protocols for amplification of complete FMD virus genomes. It was not possible to recover infectious FMDV directly from the LFDs, however following electroporation into BHK-21 cells and subsequent cell passage, infectious virus could be recovered. Therefore, these results support the use of the antigen LFD for the dry, non-hazardous transportation of samples from FMD endemic countries to international reference laboratories.

  9. [Investigation of reference intervals of blood gas and acid-base analysis assays in China].

    PubMed

    Zhang, Lu; Wang, Wei; Wang, Zhiguo

    2015-10-01

    To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument system groups and between most of two instrument system groups in all assays. The difference of reference intervals of blood gas and acid-base analysis assays used in China laboratories is moderate, which is better than other specialties in clinical laboratories.

  10. 46 CFR 164.013-2 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... All approved material incorporated by reference may be inspected at the National Archives and Records Administration (NARA), and at the U.S. Coast Guard, Lifesaving and Fire Safety Division (CG-ENG-4), 2100 2nd St... as follows: Underwriters Laboratories (UL) Underwriters Laboratories, Inc., P.O. Box 13995, Research...

  11. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    PubMed

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  12. Synthetic Nucleic Acids and Treatment of Neurological Diseases.

    PubMed

    Corey, David R

    2016-10-01

    The ability to control gene expression with antisense oligonucleotides (ASOs) could provide a new treatment strategy for disease. To review the use of ASOs for the treatment of neurological disorders. Articles were identified through a search of PubMed references from 2000 to 2016 for articles describing the use of ASOs to treat disease, with specific attention to neurological disease. We concentrated our review on articles pertaining to activation of frataxin expression (Friedreich's ataxia) and production of active survival motor neuron 2 (SMN2, spinal muscular atrophy). Many neurological diseases are caused by inappropriate expression of a protein. Mutations may reduce expression of a wild-type protein, and strategies to activate expression may provide therapeutic benefit. For other diseases, a mutant protein may be expressed too highly and methods that reduce mutant protein expression might form the basis for drug development. Synthetic ASOs can recognize cellular RNA and control gene expression. Antisense oligonucleotides are not a new concept, but successful clinical development has proceeded at a slow pace. Advances in ASO chemistry, biological understanding, and clinical design are making successful applications more likely. Both laboratory and clinical studies are demonstrating the potential of ASOs as a source of drugs to treat neurological disease.

  13. Diffusion-controlled reference material for VOC emissions testing: proof of concept.

    PubMed

    Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A

    2010-10-01

    Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.

  14. Testing practices and volume of non-Lyme tickborne diseases in the United States.

    PubMed

    Connally, Neeta P; Hinckley, Alison F; Feldman, Katherine A; Kemperman, Melissa; Neitzel, David; Wee, Siok-Bi; White, Jennifer L; Mead, Paul S; Meek, James I

    2016-02-01

    Large commercial laboratories in the United States were surveyed regarding the number of specimens tested for eight tickborne diseases in 2008. Seven large commercial laboratories reported testing a total of 2,927,881 specimens nationally (including Lyme disease). Of these, 495,585 specimens (17%) were tested for tickborne diseases other than Lyme disease. In addition to large commercial laboratories, another 1051 smaller commercial, hospital, and government laboratories in four states (CT, MD, MN, and NY) were surveyed regarding tickborne disease testing frequency, practices, and results. Ninety-two of these reported testing a total of 10,091 specimens for four tickborne diseases other than Lyme disease. We estimate the cost of laboratory diagnostic testing for non-Lyme disease tickborne diseases in 2008 to be $9.6 million. These data provide a baseline to evaluate trends in tickborne disease test utilization and insight into the burden of these diseases. Copyright © 2015 Elsevier GmbH. All rights reserved.

  15. A survey of coagulation laboratory practices and satisfaction ratings of member laboratories of the Thailand National External Quality Assessment Scheme for blood coagulation.

    PubMed

    Chuntarut, A; Tientadakul, P; Wongkrajang, P

    2016-06-01

    The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.

  16. Refractory hypocalcaemia complicating metastatic prostatic carcinoma.

    PubMed

    Rizzo, Christopher; Vella, Sandro; Cachia, Mario J

    2015-06-29

    A 72-year-old man with a background of ischaemic heart disease was referred to the accident and emergency department with a 1-week history of worsening dyspnoea and lethargy. A chest X-ray revealed a right-sided lobar pneumonia and a prolonged corrected QT interval was noted on his ECG at presentation. Laboratory investigations confirmed severe hypocalcaemia, significant vitamin D deficiency and relative hypoparathyroidism. A markedly elevated prostate-specific antigen was also identified. Bone scintigraphy demonstrated widespread osteoblastic bone metastases. Severe hypocalcaemia persisted despite treatment and he succumbed after 60 days of hospitalisation. 2015 BMJ Publishing Group Ltd.

  17. Nonlinear dynamics, fractals, cardiac physiology and sudden death

    NASA Technical Reports Server (NTRS)

    Goldberger, Ary L.

    1987-01-01

    The authors propose a diametrically opposite viewpoint to the generally accepted tendency of equating healthy function with order and disease with chaos. With regard to the question of sudden cardiac death and chaos, it is suggested that certain features of dynamical chaos related to fractal structure and fractal dynamics may be important organizing principles in normal physiology and that certain pathologies, including ventricular fibrillation, represent a class of 'pathological periodicities'. Some laboratory work bearing on the relation of nonlinear analysis to physiological and pathophysiological data is briefly reviewed, with tentative theories and models described in reference to the mechanism of ventricular fibrillation.

  18. Report from the second cytomegalovirus and immunosenescence workshop

    PubMed Central

    2011-01-01

    The Second International Workshop on CMV & Immunosenescence was held in Cambridge, UK, 2-4th December, 2010. The presentations covered four separate sessions: cytomegalovirus and T cell phenotypes; T cell memory frequency, inflation and immunosenescence; cytomegalovirus in aging, mortality and disease states; and the immunobiology of cytomegalovirus-specific T cells and effects of the virus on vaccination. This commentary summarizes the major findings of these presentations and references subsequently published work from the presenter laboratory where appropriate and draws together major themes that were subsequently discussed along with new areas of interest that were highlighted by this discussion. PMID:22035114

  19. Ebola and marburg hemorrhagic fever.

    PubMed

    Hartman, Amy L; Towner, Jonathan S; Nichol, Stuart T

    2010-03-01

    Ebola and Marburg viruses cause a severe viral hemorrhagic fever disease mainly in Sub-Saharan Africa. Although outbreaks are sporadic, there is the potential for filoviruses to spread to other continents unintentionally because of air travel or intentionally because of bioterrorism. This article discusses the natural history, epidemiology, and clinical presentation of patients infected with Ebola and Marburg viruses. Clinicians in the United States should be aware of the symptoms of these viral infections in humans and know the appropriate procedures for contacting local, state, and national reference laboratories in the event of a suspected case of filoviral hemorrhagic fever. 2010 Elsevier Inc. All rights reserved.

  20. Biosafety: guidelines for working with pathogenic and infectious microorganisms.

    PubMed

    Burnett, LouAnn C; Lunn, George; Coico, Richard

    2009-05-01

    This unit, in conjunction with local and national guidelines and regulations (see APPENDIX 1B), provides the basic biosafety information needed to perform the procedures detailed in this manual. Topics discussed include routine precautions when working with biohazards, disinfectants, disposal of biohazards, biosafety levels (as established by the U.S. National Institutes of Health and the U.S. Centers for Disease Control and Prevention), animal facilities, and clinical laboratories. In addition, resources for more information are provided in the Literature Cited and Key References sections and in URLs given within the text, as well as the Internet Resources section.

  1. Blood lipid measurements. Variations and practical utility.

    PubMed

    Cooper, G R; Myers, G L; Smith, S J; Schlant, R C

    1992-03-25

    To describe the magnitude and impact of the major biological and analytical sources of variation in serum lipid and lipoprotein levels on risk of coronary heart disease; to present a way to qualitatively estimate the total intraindividual variation; and to demonstrate how to determine the number of specimens required to estimate, with 95% confidence, the "true" underlying total cholesterol value in the serum of a patient. Representative references on each source of variation were selected from more than 300 reviewed publications, most published within the past 5 years, to document current findings and concepts. Most articles reviewed were in English. Studies on biological sources of variation were selected using the following criteria: representative of published findings, clear statement of either significant or insignificant results, and acquisition of clinical and laboratory data under standardized conditions. Representative results for special populations such as women and children are reported when results differ from those of adult men. References were selected based on acceptable experimental design and use of standardized laboratory lipid measurements. The lipid levels considered representative for a selected source of variation arose from quantitative measurements by a suitably standardized laboratory. Statistical analysis of data was examined to assure reliability. The proposed method of estimating the biological coefficient of variation must be considered to give qualitative results, because only two or three serial specimens are collected in most cases for the estimation. Concern has arisen about the magnitude, impact, and interpretation of preanalytical as well as analytical sources of variation on reported results of lipid measurements of an individual. Preanalytical sources of variation from behavioral, clinical, and sampling sources constitute about 60% of the total variation in a reported lipid measurement of an individual. A technique is presented to allow physicians to qualitatively estimate the intraindividual biological variation of a patient from the results of two or more specimens reported from a standardized laboratory and to determine whether additional specimens are needed to meet the National Cholesterol Education Program recommendation that the intraindividual serum total cholesterol coefficient of variation not exceed 5.0. A National Reference Method Network has been established to help solve analytical problems.

  2. Diagnostic tests for Niemann-Pick disease type C (NP-C): A critical review.

    PubMed

    Vanier, Marie T; Gissen, Paul; Bauer, Peter; Coll, Maria J; Burlina, Alberto; Hendriksz, Christian J; Latour, Philippe; Goizet, Cyril; Welford, Richard W D; Marquardt, Thorsten; Kolb, Stefan A

    2016-08-01

    Niemann-Pick disease type C (NP-C) is a neurovisceral lysosomal cholesterol trafficking and lipid storage disorder caused by mutations in one of the two genes, NPC1 or NPC2. Diagnosis has often been a difficult task, due to the wide range in age of onset of NP-C and clinical presentation of the disease, combined with the complexity of the cell biology (filipin) laboratory testing, even in combination with genetic testing. This has led to substantial delays in diagnosis, largely depending on the access to specialist centres and the level of knowledge about NP-C of the physician in the area. In recent years, advances in mass spectrometry has allowed identification of several sensitive plasma biomarkers elevated in NP-C (e.g. cholestane-3β,5α,6β-triol, lysosphingomyelin isoforms and bile acid metabolites), which, together with the concomitant progress in molecular genetic technology, have greatly impacted the strategy of laboratory testing. Specificity of the biomarkers is currently under investigation and other pathologies are being found to also result in elevations. Molecular genetic testing also has its limitations, notably with unidentified mutations and the classification of new variants. This review is intended to increase awareness on the currently available approaches to laboratory diagnosis of NP-C, to provide an up to date, comprehensive and critical evaluation of the various techniques (cell biology, biochemical biomarkers and molecular genetics), and to briefly discuss ongoing/future developments. The use of current tests in proper combination enables a rapid and correct diagnosis in a large majority of cases. However, even with recent progress, definitive diagnosis remains challenging in some patients, for whom combined genetic/biochemical/cytochemical markers do not provide a clear answer. Expertise and reference laboratories thus remain essential, and further work is still required to fulfill unmet needs. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Laboratory twinning to build capacity for rabies diagnosis.

    PubMed

    Fooks, Anthony R; Drew, Trevor W; Tu, Changchun

    2016-03-05

    In 2009, the UK's OIE Reference Laboratory for rabies, based at the APHA in Weybridge, was awarded a project to twin with the Changchun Veterinary Research Institute in the People's Republic of China to help the institute develop the skills and methods necessary to become an OIE Reference Laboratory itself. Here, Tony Fooks, Trevor Drew and Changchun Tu describe the OIE's twinning project and the success that has since been realised in China. British Veterinary Association.

  4. 77 FR 14805 - Clinical Laboratory Improvement Advisory Committee, Centers for Disease Control and Prevention...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Clinical Laboratory Improvement Advisory Committee, Centers for Disease Control and Prevention: Notice of Charter..., that the Clinical Laboratory Improvement Advisory Committee, Centers for Disease Control and Prevention...

  5. [Reference values for lead in blood in urban population in southern Brazil].

    PubMed

    Paoliello, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Carvalho, S R; Alvarenga, A L; Rezende, M I; Figueiroa, G A; Leite, V G; Gutierrez, A C; Lobo, B C; Cascales, R A

    2001-05-01

    To describe the reference values for lead in blood in an urban population in the city of Londrina, in the state of Paraná, Brazil. The reference population was composed of 520 adult volunteers who were assessed from November 1994 to December 1996. Exclusion criteria were: occupational exposure to lead, exposure through personal habits or practices, smoking more than 10 cigarettes per day, and living near industrial plants or other places that use lead in their production processes. Also excluded were individuals with abnormal clinical or laboratory results or with chronic diseases or cardiovascular disorders. Lead blood levels were determined using air-acetylene flame atomic absorption spectrophotometry. The detectable limit was 1.23 micrograms/dL. After the analyses of lead in blood, the following values were determined: minimum value, first quartile, median, third quartile, and maximum value; geometric mean; 95% confidence interval; experimental interval; and reference value. The reference values for lead in blood ranged from 1.20 micrograms/dL to 13.72 micrograms/dL. The geometric mean was 5.5 micrograms/dL. In general, the values found in this study are lower than those that have been reported for other countries. Additional data should be gathered from Brazilian populations living in more-industrialized areas.

  6. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  7. Review of recent trends in cholera research and control

    PubMed Central

    Felsenfeld, O.

    1966-01-01

    Since 1961 cholera El Tor has been sweeping through the Far East, and this dissemination of the disease has stimulated research not only in the countries afflicted but also in Europe and the Americas. New laboratories and workers have entered the field and many fresh ideas and concepts have emerged. The time seemed ripe, therefore, to survey the most important papers published since 1959, when the literature on cholera was thoroughly reviewed by Pollitzer, for the benefit both of those engaged in research and of those concerned with public health practice. This review covers history and incidence, causative agents (including the ”classical”, ”El Tor” and ”incomplete” forms), pathophysiology, diagnosis, treatment, mode of spreading and control measures (with particular reference to public health education and the International Sanitary Regulations). An annex, intended for laboratory use, contains selected procedures for the isolation and identification of cholera vibrios. PMID:5328492

  8. [Importance of medical education in the diagnosis of toxoplasmosis in Cuba].

    PubMed

    Gavito, Dora Emma Ginorio; Duque, María Victoria Rodríguez; Iraola, Raimundo Cox; Galindo, Luis Fonte; Rivero, Lázara Rojas

    2003-01-01

    The results of the National Toxoplasmosis Reference Laboratory during 1999 and 2000 were processed and the evaluations on this topic were simultaneously analyzed among 51 professionals that attended the First National Workshop held at "Pedro Kouri" Institute of Tropical Medicine at that time. Of 3 672 orders, 3 171 (86.3%) did not have the reason for serology, 36.1% had no place of origin and only 301 cases (8.1%) were indicated the matched serum. On analyzing the main causes leading to make this test, 13.5% corresponded to repeated abortions, which is not accepted at present as a clinical manifestation in the course of the disease. Coincidentally, when some professionals were evaluated through a survey about the basic aspects related to this parasitosis, only 31.3% were able to obtain satisfactory marks. Most of the mistakes were observed in the interpretation of the laboratory results.

  9. Use of HOMA-IR to diagnose non-alcoholic fatty liver disease: a population-based and inter-laboratory study.

    PubMed

    Isokuortti, Elina; Zhou, You; Peltonen, Markku; Bugianesi, Elisabetta; Clement, Karine; Bonnefont-Rousselot, Dominique; Lacorte, Jean-Marc; Gastaldelli, Amalia; Schuppan, Detlef; Schattenberg, Jörn M; Hakkarainen, Antti; Lundbom, Nina; Jousilahti, Pekka; Männistö, Satu; Keinänen-Kiukaanniemi, Sirkka; Saltevo, Juha; Anstee, Quentin M; Yki-Järvinen, Hannele

    2017-10-01

    Recent European guidelines for non-alcoholic fatty liver disease (NAFLD) call for reference values for HOMA-IR. In this study, we aimed to determine: (1) the upper limit of normal HOMA-IR in two population-based cohorts; (2) the HOMA-IR corresponding to NAFLD; (3) the effect of sex and PNPLA3 genotype at rs738409 on HOMA-IR; and (4) inter-laboratory variations in HOMA-IR. We identified healthy individuals in two population-based cohorts (FINRISK 2007 [n = 5024] and the Programme for Prevention of Type 2 Diabetes in Finland [FIN-D2D; n = 2849]) to define the upper 95th percentile of HOMA-IR. Non-obese individuals with normal fasting glucose levels, no excessive alcohol use, no known diseases and no use of any drugs were considered healthy. The optimal HOMA-IR cut-off for NAFLD (liver fat ≥5.56%, based on the Dallas Heart Study) was determined in 368 non-diabetic individuals (35% with NAFLD), whose liver fat was measured using proton magnetic resonance spectroscopy ( 1 H-MRS). Samples from ten individuals were simultaneously analysed for HOMA-IR in seven European laboratories. The upper 95th percentiles of HOMA-IR were 1.9 and 2.0 in healthy individuals in the FINRISK (n = 1167) and FIN-D2D (n = 459) cohorts. Sex or PNPLA3 genotype did not influence these values. The optimal HOMA-IR cut-off for NAFLD was 1.9 (sensitivity 87%, specificity 79%). A HOMA-IR of 2.0 corresponded to normal liver fat (<5.56% on 1 H-MRS) in linear regression analysis. The 2.0 HOMA-IR measured in Helsinki corresponded to 1.3, 1.6, 1.8, 1.8, 2.0 and 2.1 in six other laboratories. The inter-laboratory CV% of HOMA-IR was 25% due to inter-assay variation in insulin (25%) rather than glucose (5%) measurements. The upper limit of HOMA-IR in population-based cohorts closely corresponds to that of normal liver fat. Standardisation of insulin assays would be the first step towards definition of normal values for HOMA-IR.

  10. Mouse Genome Informatics (MGI) Resource: Genetic, Genomic, and Biological Knowledgebase for the Laboratory Mouse.

    PubMed

    Eppig, Janan T

    2017-07-01

    The Mouse Genome Informatics (MGI) Resource supports basic, translational, and computational research by providing high-quality, integrated data on the genetics, genomics, and biology of the laboratory mouse. MGI serves a strategic role for the scientific community in facilitating biomedical, experimental, and computational studies investigating the genetics and processes of diseases and enabling the development and testing of new disease models and therapeutic interventions. This review describes the nexus of the body of growing genetic and biological data and the advances in computer technology in the late 1980s, including the World Wide Web, that together launched the beginnings of MGI. MGI develops and maintains a gold-standard resource that reflects the current state of knowledge, provides semantic and contextual data integration that fosters hypothesis testing, continually develops new and improved tools for searching and analysis, and partners with the scientific community to assure research data needs are met. Here we describe one slice of MGI relating to the development of community-wide large-scale mutagenesis and phenotyping projects and introduce ways to access and use these MGI data. References and links to additional MGI aspects are provided. © The Author 2017. Published by Oxford University Press.

  11. Mouse Genome Informatics (MGI) Resource: Genetic, Genomic, and Biological Knowledgebase for the Laboratory Mouse

    PubMed Central

    Eppig, Janan T.

    2017-01-01

    Abstract The Mouse Genome Informatics (MGI) Resource supports basic, translational, and computational research by providing high-quality, integrated data on the genetics, genomics, and biology of the laboratory mouse. MGI serves a strategic role for the scientific community in facilitating biomedical, experimental, and computational studies investigating the genetics and processes of diseases and enabling the development and testing of new disease models and therapeutic interventions. This review describes the nexus of the body of growing genetic and biological data and the advances in computer technology in the late 1980s, including the World Wide Web, that together launched the beginnings of MGI. MGI develops and maintains a gold-standard resource that reflects the current state of knowledge, provides semantic and contextual data integration that fosters hypothesis testing, continually develops new and improved tools for searching and analysis, and partners with the scientific community to assure research data needs are met. Here we describe one slice of MGI relating to the development of community-wide large-scale mutagenesis and phenotyping projects and introduce ways to access and use these MGI data. References and links to additional MGI aspects are provided. PMID:28838066

  12. Feline leprosy due to Mycobacterium lepraemurium.

    PubMed

    O'Brien, Carolyn R; Malik, Richard; Globan, Maria; Reppas, George; McCowan, Christina; Fyfe, Janet A

    2017-07-01

    This paper, the second in a series of three on 'feline leprosy', provides a detailed description of disease referable to Mycobacterium lepraemurium, the most common cause of feline leprosy worldwide. Cases were sourced retrospectively and prospectively for this observational study, describing clinical, geographical and molecular microbiological data for cats definitively diagnosed with M lepraemurium infection. A total of 145 cases of feline leprosy were scrutinised; 114 'new' cases were sourced from the Victorian Infectious Diseases Reference Laboratory records, veterinary pathology laboratories or veterinarians, and 31 cases were derived from six published studies. Sixty-five cats were definitively diagnosed with M lepraemurium infection. Typically, cats were 1-3 years of age when first infected, with a male gender predilection. Affected cats were generally systemically well. All had outdoor access. Lesions tended to consist of one or more cutaneous/subcutaneous nodules, typically located on the head and/or forelimbs, possibly reflecting the most likely locations for a rodent bite as the site of inoculation for organisms. Nodules had the propensity to ulcerate at some stage in the clinical course. The cytological and histological picture varied from tuberculoid, with relatively low bacterial numbers, to lepromatous with moderate to high bacterial numbers. Treatment was varied, although most cats underwent surgical resection of lesions with adjunctive medical therapy, most often using a combination of oral clarithromycin and rifampicin. Prognosis for recovery was generally good, and in two cases there was spontaneous remission without the requirement for medical intervention. Untreated cats continued to enjoy an acceptable quality of life despite persistence of the disease, which extended locally but had no apparent tendency to disseminate to internal organs. M lepraemurium causes high bacterial index (lepromatous) or low bacterial index (tuberculoid) feline leprosy. The infection typically causes nodules of the skin and/or subcutis (which tend towards ulceration) on the head and/or forelimbs. The disease usually has an indolent clinical course and infected cats have a generally favourable response to therapeutic interventions, with rare cases undergoing spontaneous resolution. Genomic analysis may yield clues as to the environmental niche and culture requirements of this elusive organism. Prospective treatment trials and/or additional drug susceptibility testing in specialised systems would further inform treatment recommendations.

  13. The theory of reference values: an unfinished symphony.

    PubMed

    Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter

    2013-01-01

    The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!

  14. European specialist porphyria laboratories: diagnostic strategies, analytical quality, clinical interpretation, and reporting as assessed by an external quality assurance program.

    PubMed

    Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre

    2011-11-01

    The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.

  15. Characterization of equine vitamin D-binding protein, development of an assay, and assessment of plasma concentrations of the protein in healthy horses and horses with gastrointestinal disease.

    PubMed

    Pihl, Tina H; Jacobsen, Stine; Olsen, Dorthe T; Højrup, Peter; Grosche, Astrid; Freeman, David E; Andersen, Pia H; Houen, Gunnar

    2017-06-01

    OBJECTIVE To purify and characterize equine vitamin D-binding protein (VDBP) from equine serum and to evaluate plasma concentrations of VDBP in healthy horses and horses with gastrointestinal injury or disease. ANIMALS 13 healthy laboratory animals (8 mice and 5 rabbits), 61 healthy horses, 12 horses with experimentally induced intestinal ischemia and reperfusion (IR), and 59 horses with acute gastrointestinal diseases. PROCEDURES VDBP was purified from serum of 2 healthy horses, and recombinant equine VDBP was obtained through a commercial service. Equine VDBP was characterized by mass spectrometry. Monoclonal and polyclonal antibodies were raised against equine VDBP, and a rocket immunoelectrophoresis assay for equine VDBP was established. Plasma samples from 61 healthy horses were used to establish working VDBP reference values for study purposes. Plasma VDBP concentrations were assessed at predetermined time points in horses with IR and in horses with naturally occurring gastrointestinal diseases. RESULTS The working reference range for plasma VDBP concentration in healthy horses was 531 to 1,382 mg/L. Plasma VDBP concentrations were significantly decreased after 1 hour of ischemia in horses with IR, compared with values prior to induction of ischemia, and were significantly lower in horses with naturally occurring gastrointestinal diseases with a colic duration of < 12 hours than in healthy horses. CONCLUSIONS AND CLINICAL RELEVANCE Plasma VDBP concentrations were significantly decreased in horses with acute gastrointestinal injury or disease. Further studies and the development of a clinically relevant assay are needed to establish the reliability of VDBP as a diagnostic and prognostic marker in horses.

  16. Clinical Variant Classification: A Comparison of Public Databases and a Commercial Testing Laboratory.

    PubMed

    Gradishar, William; Johnson, KariAnne; Brown, Krystal; Mundt, Erin; Manley, Susan

    2017-07-01

    There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, the well-documented limitations of these databases call into question how often clinicians will encounter discordant variant classifications that may introduce uncertainty into patient management. Here, we evaluate discordance in BRCA1 and BRCA2 variant classifications between a single commercial testing laboratory and a public database commonly consulted in clinical practice. BRCA1 and BRCA2 variant classifications were obtained from ClinVar and compared with the classifications from a reference laboratory. Full concordance and discordance were determined for variants whose ClinVar entries were of the same pathogenicity (pathogenic, benign, or uncertain). Variants with conflicting ClinVar classifications were considered partially concordant if ≥1 of the listed classifications agreed with the reference laboratory classification. Four thousand two hundred and fifty unique BRCA1 and BRCA2 variants were available for analysis. Overall, 73.2% of classifications were fully concordant and 12.3% were partially concordant. The remaining 14.5% of variants had discordant classifications, most of which had a definitive classification (pathogenic or benign) from the reference laboratory compared with an uncertain classification in ClinVar (14.0%). Here, we show that discrepant classifications between a public database and single reference laboratory potentially account for 26.7% of variants in BRCA1 and BRCA2 . The time and expertise required of clinicians to research these discordant classifications call into question the practicality of checking all test results against a database and suggest that discordant classifications should be interpreted with these limitations in mind. With the increasing use of clinical genetic testing for hereditary cancer risk, accurate variant classification is vital to ensuring appropriate medical management. There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, we show that up to 26.7% of variants in BRCA1 and BRCA2 have discordant classifications between ClinVar and a reference laboratory. The findings presented in this paper serve as a note of caution regarding the utility of database consultation. © AlphaMed Press 2017.

  17. Effluent-Monitoring Procedures: Basic Laboratory Skills. Student Reference Manual.

    ERIC Educational Resources Information Center

    Engel, William T.; And Others

    This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. This Student Reference Manual provides a review of basic mathematics as it applies to the chemical laboratory. The…

  18. Skin photoprotection by natural polyphenols: anti-inflammatory, antioxidant and DNA repair mechanisms.

    PubMed

    Nichols, Joi A; Katiyar, Santosh K

    2010-03-01

    Epidemiological, clinical and laboratory studies have implicated solar ultraviolet (UV) radiation in various skin diseases including, premature aging of the skin and melanoma and non-melanoma skin cancers. Chronic UV radiation exposure-induced skin diseases or skin disorders are caused by the excessive induction of inflammation, oxidative stress and DNA damage, etc. The use of chemopreventive agents, such as plant polyphenols, to inhibit these events in UV-exposed skin is gaining attention. Chemoprevention refers to the use of agents that can inhibit, reverse or retard the process of these harmful events in the UV-exposed skin. A wide variety of polyphenols or phytochemicals, most of which are dietary supplements, have been reported to possess substantial skin photoprotective effects. This review article summarizes the photoprotective effects of some selected polyphenols, such as green tea polyphenols, grape seed proanthocyanidins, resveratrol, silymarin and genistein, on UV-induced skin inflammation, oxidative stress and DNA damage, etc., with a focus on mechanisms underlying the photoprotective effects of these polyphenols. The laboratory studies conducted in animal models suggest that these polyphenols have the ability to protect the skin from the adverse effects of UV radiation, including the risk of skin cancers. It is suggested that polyphenols may favorably supplement sunscreens protection, and may be useful for skin diseases associated with solar UV radiation-induced inflammation, oxidative stress and DNA damage.

  19. Comparative Evaluation of 11 Commercialized Rapid Diagnostic Tests for Detecting Trypanosoma cruzi Antibodies in Serum Banks in Areas of Endemicity and Nonendemicity

    PubMed Central

    Albajar-Viñas, Pedro; Wilkins, Patricia P.; Nieto, Javier; Leiby, David A.; Paris, Luc; Scollo, Karenina; Flórez, Carolina; Guzmán-Bracho, Carmen; Luquetti, Alejandro O.; Calvo, Nidia; Tadokoro, Kenji; Saez-Alquezar, Amadeo; Palma, Pedro Pablo; Martin, Miguel

    2014-01-01

    Chagas disease is one of the main public health issues in Latin America. Increasingly during the past few decades, Trypanosoma cruzi infection has been detected in North America, Europe, and the Western Pacific, mainly as a result of population movement. The limited availability of rapid serological diagnostic tests hinders rapid diagnosis and early treatment in areas of endemicity and nonendemicity. In collaboration with 11 national reference laboratories (NRLs) from different geographical areas, we evaluated the performances of commercialized serological rapid diagnostic tests (RDT) for T. cruzi infection. Eleven commercialized T. cruzi infection RDTs were evaluated on a total of 474 samples extensively tested with at least three different techniques for Chagas disease, maintained at controlled low temperatures, and stored in the serum banks of the 11 NRLs. We measured the sensitivity, specificity, and concordance of each RDT and provided an additional questionnaire to evaluate its ease of use. The selected RDTs in this study were performed under controlled laboratory conditions. Out of the 11 RDTs, we found 8 of them to be useful, with the cassette format favored over the strip. We did not observe significant differences in RDT performances in the different regions. Overall, the performance results were lower than those disclosed by the manufacturers. The results of this evaluation validate the possibility of using RDTs to diagnose Chagas disease, thereby decreasing the time to treatment at a primary health care facility for patients who are willing to be treated. Further studies should be conducted in the laboratory and in the field to confirm these data, expressly to evaluate reproducibility in resource-limited settings, or using whole blood in clinical settings in areas of endemicity and nonendemicity. PMID:24808239

  20. Evaluation of Two Lyophilized Molecular Assays to Rapidly Detect Foot-and-Mouth Disease Virus Directly from Clinical Samples in Field Settings.

    PubMed

    Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L

    2017-06-01

    Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  1. GCR Simulator Reference Field and a Spectral Approach for Laboratory Simulation

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Blattnig, Steve R.; Norbury, John W.; Rusek, Adam; La Tessa, Chiara; Walker, Steven A.

    2015-01-01

    The galactic cosmic ray (GCR) simulator at the NASA Space Radiation Laboratory (NSRL) is intended to deliver the broad spectrum of particles and energies encountered in deep space to biological targets in a controlled laboratory setting. In this work, certain aspects of simulating the GCR environment in the laboratory are discussed. Reference field specification and beam selection strategies at NSRL are the main focus, but the analysis presented herein may be modified for other facilities. First, comparisons are made between direct simulation of the external, free space GCR field and simulation of the induced tissue field behind shielding. It is found that upper energy constraints at NSRL limit the ability to simulate the external, free space field directly (i.e. shielding placed in the beam line in front of a biological target and exposed to a free space spectrum). Second, variation in the induced tissue field associated with shielding configuration and solar activity is addressed. It is found that the observed variation is likely within the uncertainty associated with representing any GCR reference field with discrete ion beams in the laboratory, given current facility constraints. A single reference field for deep space missions is subsequently identified. Third, an approach for selecting beams at NSRL to simulate the designated reference field is presented. Drawbacks of the proposed methodology are discussed and weighed against alternative simulation strategies. The neutron component and track structure characteristics of the simulated field are discussed in this context.

  2. Exhaled breath condensate – from an analytical point of view

    PubMed Central

    Dodig, Slavica; Čepelak, Ivana

    2013-01-01

    Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease. PMID:24266297

  3. Pediatric Autoimmune Neuropsychiatric Disorder Associated with Streptococcal Infections (PANDAS): Experience at a Tertiary Referral Center.

    PubMed

    Helm, Caitlin E; Blackwood, R Alexander

    2015-01-01

    Pediatric autoimmune neuropsychiatric disorder associated with streptococcal infections (PANDAS) is an autoimmune disorder presenting with obsessive compulsive disorder and/or tics. Like Sydenham's chorea, its presumed pathogenesis consists of autoantibodies cross-reacting with neurons in response to a group A beta-hemolytic streptococcal infection (GASI). There are currently no diagnostic laboratory findings and management ranges from antibiotic prophylaxis to intravenous immunoglobulin to plasmapheresis. The diagnosis remains controversial, resulting in inconsistent referrals and significant patient anxiety. A retrospective study was performed on all patients referred to the Pediatric Infectious Disease Division with a pre-referral diagnosis of PANDAS. Patients were analyzed by demographics, medical history, co-morbidities, symptoms, prior treatment, laboratory tests, management strategies, and treatment outcomes. From 2003 to 2013, there were 21 patients with a pre-referral diagnosis of PANDAS. Only five met the diagnostic criteria. No patient at referral had an objective scale to monitor symptoms. Eight referrals had a major psychiatric disorder, and none fulfilled diagnostic criteria (p<0.01). The majority of the patients referred with a pre-diagnosis of PANDAS do not fulfill diagnostic criteria nor do they have objective criteria for symptom monitoring. Major psychiatric disorders do not seem to be associated with PANDAS, and better physician education may prevent misdiagnoses. Multidisciplinary management is recommended.

  4. [Immunodiagnosis of endemic mycoses and bronchopulmonary aspergillosis: a multicenter study in Argentina].

    PubMed

    Canteros, C E; Rivas, M C; Soria, M; Lee, W; Perrotta, D; Rodero, L; Davel, G

    2004-01-01

    In order to contribute to the knowledge of the relative frequency of chronic fungal diseases and assess the performance of diagnostic laboratories in Argentina, a multicenter study was performed with the participation of 25 medical centers located in 12 different provinces and Buenos Aires City. Between 04-01-2000 and 03-30-2001, 965 serum specimens from patients clinically suspected of having histoplasmosis (HP), paracoccidioidomycosis (PCM), coccidioidomycosis (CM) or aspergilosis were analyzed. Agar immunodiffusion tests (IDD) were done locally. All positive and 35% of negative sera were retested in the reference center. Results of laboratories of origin showed 98.8% concordance with those of reference center. Antibodies against any of the etiological agents were detected in 120 specimens from 98 patients. Endemic mycoses (HP, PCM and CM) were diagnosed in 70 patients (71.4%) and aspergilosis in 28 (28.6%). The frequencies of the different mycoses in decreasing order were PCM 47 patients (47.9%), aspergilosis 28 patients (28.6%), HP 13 patients (13.3%) and CM 10 patients (10.2%). The study was carried out on a voluntary basis and some areas of the country were not represented. However, the frequencies were in range with the expected rates in the population under study.

  5. Diagnostic tool for red blood cell membrane disorders: Assessment of a new generation ektacytometer.

    PubMed

    Da Costa, Lydie; Suner, Ludovic; Galimand, Julie; Bonnel, Amandine; Pascreau, Tiffany; Couque, Nathalie; Fenneteau, Odile; Mohandas, Narla

    2016-01-01

    Inherited red blood cell (RBC) membrane disorders, such as hereditary spherocytosis, elliptocytosis and hereditary ovalocytosis, result from mutations in genes encoding various RBC membrane and skeletal proteins. The RBC membrane, a composite structure composed of a lipid bilayer linked to a spectrin/actin-based membrane skeleton, confers upon the RBC unique features of deformability and mechanical stability. The disease severity is primarily dependent on the extent of membrane surface area loss. RBC membrane disorders can be readily diagnosed by various laboratory approaches that include RBC cytology, flow cytometry, ektacytometry, electrophoresis of RBC membrane proteins and genetics. The reference technique for diagnosis of RBC membrane disorders is the osmotic gradient ektacytometry. However, in spite of its recognition as the reference technique, this technique is rarely used as a routine diagnosis tool for RBC membrane disorders due to its limited availability. This may soon change as a new generation of ektacytometer has been recently engineered. In this review, we describe the workflow of the samples shipped to our Hematology laboratory for RBC membrane disorder analysis and the data obtained for a large cohort of French patients presenting with RBC membrane disorders using a newly available version of the ektacytomer. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Dual infections with different Legionella strains.

    PubMed

    Wewalka, G; Schmid, D; Harrison, T G; Uldum, S A; Lück, C

    2014-01-01

    In 2010 a case of a dual infection with Legionella pneumophila serogroup (sg) 1 and sg 3 was identified by culture of a blood sample collected from a female Austrian patient with septic pneumonia. Subsequently all 35 European National Legionella Reference Laboratories were interviewed regarding the frequency of dual infections in legionellosis. The Reference Laboratories in Denmark, the UK and Germany reported the detection of another 14 cases of dual infections with different Legionella strains between 2002 and 2012. Among the 15 cases, there were four cases with different Legionella species, six cases with different L. pneumophila serogroups, and five cases of dual infections with L. pneumophila sg 1 with different MAb-types. The median age of the 15 cases was 56 years and the male to female ratio 1:1.14. Six of the 15 patients were receiving immunosuppressive treatment following organ transplantation (n = 3) or for underlying haematological and solid malignancies (n = 3). Five of the 15 cases died within 30 days following diagnosis. Efforts to detect dual infections with different Legionella strains will improve our ability to correctly elucidate the causative sources of infection and enhance our understanding of the epidemiology of Legionella infections. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  7. Standardization of gamma-glutamyltransferase assays by intermethod calibration. Effect on determining common reference limits.

    PubMed

    Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph

    2007-01-01

    The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.

  8. Sexual orientation and adolescents.

    PubMed

    Frankowski, Barbara L

    2004-06-01

    The American Academy of Pediatrics issued its first statement on homosexuality and adolescents in 1983, with a revision in 1993. This report reflects the growing understanding of youth of differing sexual orientations. Young people are recognizing their sexual orientation earlier than in the past, making this a topic of importance to pediatricians. Pediatricians should be aware that some youths in their care may have concerns about their sexual orientation or that of siblings, friends, parents, relatives, or others. Health care professionals should provide factual, current, nonjudgmental information in a confidential manner. All youths, including those who know or wonder whether they are not heterosexual, may seek information from physicians about sexual orientation, sexually transmitted diseases, substance abuse, or various psychosocial difficulties. The pediatrician should be attentive to various potential psychosocial difficulties, offer counseling or refer for counseling when necessary and ensure that every sexually active youth receives a thorough medical history, physical examination, immunizations, appropriate laboratory tests, and counseling about sexually transmitted diseases (including human immunodeficiency virus infection) and appropriate treatment if necessary. Not all pediatricians may feel able to provide the type of care described in this report. Any pediatrician who is unable to care for and counsel nonheterosexual youth should refer these patients to an appropriate colleague.

  9. Optical Fiber Power Meter Comparison Between NIST and NIM.

    PubMed

    Vayshenker, I; Livigni, D J; Li, X; Lehman, J H; Li, J; Xiong, L M; Zhang, Z X

    2010-01-01

    We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and National Institute of Metrology (NIM-China). We report optical fiber-based power measurements at nominal wavelengths of 1310 nm and 1550 nm. We compare the laboratories' reference standards by means of a commercial optical power meter. Measurement results showed the largest difference of less than 2.6 parts in 10(3), which is within the combined standard (k = 1) uncertainty for the laboratories' reference standards.

  10. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  11. Laboratory diagnosis of melioidosis: Past, present and future

    PubMed Central

    Lau, Susanna KP; Sridhar, Siddharth; Ho, Chi-Chun; Chow, Wang-Ngai; Lee, Kim-Chung; Lam, Ching-Wan; Yuen, Kwok-Yung

    2015-01-01

    Melioidosis is an emerging, potentially fatal disease caused by Burkholderia pseudomallei, which requires prolonged antibiotic treatment to prevent disease relapse. However, difficulties in laboratory diagnosis of melioidosis may delay treatment and affect disease outcomes. Isolation of B. pseudomallei from clinical specimens has been improved with the use of selective media. However, even with positive cultures, identification of B. pseudomallei can be difficult in clinical microbiology laboratories, especially in non-endemic areas where clinical suspicion is low. Commercial identification systems may fail to distinguish between B. pseudomallei and closely related species such as Burkholderia thailandensis. Genotypic identification of suspected isolates can be achieved by sequencing of gene targets such as groEL which offer higher discriminative power than 16S rRNA. Specific PCR-based identification of B. pseudomallei has also been developed using B. pseudomallei-specific gene targets such as Type III secretion system and Tat-domain protein. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolutionary technique for pathogen identification, has been shown to be potentially useful for rapid identification of B. pseudomallei, although existing databases require optimization by adding reference spectra for B. pseudomallei. Despite these advances in bacterial identification, diagnostic problems encountered in culture-negative cases remain largely unresolved. Although various serological tests have been developed, they are generally unstandardized “in house” assays and have low sensitivities and specificities. Although specific PCR assays have been applied to direct clinical and environmental specimens, the sensitivities for diagnosis remain to be evaluated. Metabolomics is an uprising tool for studying infectious diseases and may offer a novel approach for exploring potential diagnostic biomarkers. The metabolomics profiles of B. pseudomallei culture supernatants can be potentially distinguished from those of related bacterial species including B. thailandensis. Further studies using bacterial cultures and direct patient samples are required to evaluate the potential of metabolomics for improving diagnosis of melioidosis. PMID:25908634

  12. Demographics of the European Apicultural Industry

    PubMed Central

    Chauzat, Marie-Pierre; Cauquil, Laura; Roy, Lise; Franco, Stéphanie; Hendrikx, Pascal; Ribière-Chabert, Magali

    2013-01-01

    Over the last few years, many European and North American countries have reported a high rate of disorders (mortality, dwindling and disappearance) affecting honeybee colonies (Apis mellifera). Although beekeeping has become an increasingly professional activity in recent years, the beekeeping industry remains poorly documented in Europe. The European Union Reference Laboratory for Honeybee Health sent a detailed questionnaire to each Member State, in addition to Kosovo and Norway, to determine the demographics and state of their beekeeping industries. Based on data supplied by the National Reference Laboratory for honeybee diseases in each European country, a European database was created to describe the beekeeping industry including the number and types of beekeepers, operation size, industry production, and health (notifiable diseases, mortalities). The total number of beekeepers in Europe was estimated at 620 000. European honey production was evaluated at around 220 000 tons in 2010. The price of honey varied from 1.5 to 40 €/kg depending on the country and on the distribution network. The estimated colony winter mortality varied from 7 to 28% depending on the country and the origin of the data (institutional survey or beekeeping associations). This survey documents the high heterogeneity of the apicultural industry within the European Union. The high proportion of non-professional beekeepers and the small mean number of colonies per beekeeper were the only common characteristics at European level. The tremendous variation in European apicultural industries has implication for any comprehensive epidemiological or economic analysis of the industry. This variability needs to be taken into account for such analysis as well as for future policy development. The industry would be served if beekeeping registration was uniformly implemented across member states. Better information on the package bee and queen production would help in understanding the ability of the industry to replace lost honey bee stocks. PMID:24236084

  13. [A case of Crimean-Congo hemorrhagic fever with long incubation period in Kocaeli, Turkey].

    PubMed

    Meriç Koç, Meliha; Willke, Ayşe

    2012-01-01

    Crimean-Congo hemorrhagic fever (CCHF) is a viral hemorrhagic disease with high mortality rate. CCHF is endemic in Central Anatolia and East and Central Black Sea parts of Turkey, however sporadic cases have been detected in the other regions. The incubation period of the disease is between 1-3 days (maximum 12 days). In this report, a very rare CCHF case with a long incubation period of 30 days, was reported. A 40-year-old female patient living in a village of Kocaeli, Turkey was admitted to a health center in June 2010 with the complaints of headache, myalgia, nausea, vomiting, fatigue and fever. Since laboratory results revealed severe thrombocytopenia (18.300/mm3), the patient was referred to the university hospital in Kocaeli. It was learned from her history that she had been working in the garden and removed a tick from the skin of gluteal area a month ago without seeking any medical help. Physical examination of the patient revealed that her general condition was well, oriented and cooperative, body temperature was 36.6°C, pulse 82/minute, trombocyte count 69.400/mm3 and liver enzymes were elevated (ALT: 194 U/L, AST: 499 U/L, GGT: 384 U/L, LDH: 1290 U/L). Petecchial lesions were seen on hard palate and extremities and a hyperemic lesion was detected at the gluteal area where the tick had attached. In-house real-time polymerase chain reaction test for CCHF, performed at Refik Saydam National Public Health Agency, Virology Reference and Research Laboratory, revealed positive result. This case was presented to withdraw attention to a long incubation period CCHF and also of its epidemiological importance since it was the first case in Kocaeli province, Turkey.

  14. Serologic screening for Trypanosoma cruzi among blood donors in central Brazil.

    PubMed

    de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F

    1992-01-01

    The study reported here compares results obtained by blood banks screening sera for chagasic (Trypanosoma cruzi) infection with results obtained by the Chagas' Disease Reference Laboratory of the Federal University of Goiás in Goiânia, Brazil. It also evaluates results obtained using the ELISA technique to screen the study sera. The survey used data from six of eight blood banks serving the city of Goiânia, an urban region of Central Brazil where Chagas' disease is highly endemic. The survey population consisted of 1,513 voluntary first-time blood donors whose donations occurred between October 1988 and April 1989. This group included 50% of all the first-time blood donors in that period. The six participating blood banks, which accounted for about 90% of all blood donations in Goiânia during the study period, routinely used indirect hemagglutination (IHA) and complement fixation (CF) tests to screen sera for antibodies to T. cruzi. Comparison of the results provided by the blood banks with the reference laboratory's results indicated a relative sensitivity of 77%, which ranged from 50% to 100% depending on the blood bank studied. The comparison, which found 12 false negative results, indicated that transfusions of infected blood might have occurred despite the serologic screening performed by the blood banks. Relative to the standard of positivity established for the study, the enzyme-linked immunosorbent assay (ELISA) technique was found to have a sensitivity of 96.3%. Considering as positive only those sera yielding positive IHA and indirect immunofluorescence (IIF) test results, the ELISA technique yielded 2 false negative and 41 false positive responses.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Demographics of the European apicultural industry.

    PubMed

    Chauzat, Marie-Pierre; Cauquil, Laura; Roy, Lise; Franco, Stéphanie; Hendrikx, Pascal; Ribière-Chabert, Magali

    2013-01-01

    Over the last few years, many European and North American countries have reported a high rate of disorders (mortality, dwindling and disappearance) affecting honeybee colonies (Apis mellifera). Although beekeeping has become an increasingly professional activity in recent years, the beekeeping industry remains poorly documented in Europe. The European Union Reference Laboratory for Honeybee Health sent a detailed questionnaire to each Member State, in addition to Kosovo and Norway, to determine the demographics and state of their beekeeping industries. Based on data supplied by the National Reference Laboratory for honeybee diseases in each European country, a European database was created to describe the beekeeping industry including the number and types of beekeepers, operation size, industry production, and health (notifiable diseases, mortalities). The total number of beekeepers in Europe was estimated at 620,000. European honey production was evaluated at around 220,000 tons in 2010. The price of honey varied from 1.5 to 40 €/kg depending on the country and on the distribution network. The estimated colony winter mortality varied from 7 to 28% depending on the country and the origin of the data (institutional survey or beekeeping associations). This survey documents the high heterogeneity of the apicultural industry within the European Union. The high proportion of non-professional beekeepers and the small mean number of colonies per beekeeper were the only common characteristics at European level. The tremendous variation in European apicultural industries has implication for any comprehensive epidemiological or economic analysis of the industry. This variability needs to be taken into account for such analysis as well as for future policy development. The industry would be served if beekeeping registration was uniformly implemented across member states. Better information on the package bee and queen production would help in understanding the ability of the industry to replace lost honey bee stocks.

  16. Evaluation of locally established reference intervals for hematology and biochemistry parameters in Western Kenya.

    PubMed

    Odhiambo, Collins; Oyaro, Boaz; Odipo, Richard; Otieno, Fredrick; Alemnji, George; Williamson, John; Zeh, Clement

    2015-01-01

    Important differences have been demonstrated in laboratory parameters from healthy persons in different geographical regions and populations, mostly driven by a combination of genetic, demographic, nutritional, and environmental factors. Despite this, European and North American derived laboratory reference intervals are used in African countries for patient management, clinical trial eligibility, and toxicity determination; which can result in misclassification of healthy persons as having laboratory abnormalities. An observational prospective cohort study known as the Kisumu Incidence Cohort Study (KICoS) was conducted to estimate the incidence of HIV seroconversion and identify determinants of successful recruitment and retention in preparation for an HIV vaccine/prevention trial among young adults and adolescents in western Kenya. Laboratory values generated from the KICoS were compared to published region-specific reference intervals and the 2004 NIH DAIDS toxicity tables used for the trial. About 1106 participants were screened for the KICoS between January 2007 and June 2010. Nine hundred and fifty-three participants aged 16 to 34 years, HIV-seronegative, clinically healthy, and non-pregnant were selected for this analysis. Median and 95% reference intervals were calculated for hematological and biochemistry parameters. When compared with both published region-specific reference values and the 2004 NIH DAIDS toxicity table, it was shown that the use of locally established reference intervals would have resulted in fewer participants classified as having abnormal hematological or biochemistry values compared to US derived reference intervals from DAIDS (10% classified as abnormal by local parameters vs. >40% by US DAIDS). Blood urea nitrogen was most often out of range if US based intervals were used: <10% abnormal by local intervals compared to >83% by US based reference intervals. Differences in reference intervals for hematological and biochemical parameters between western and African populations highlight importance of developing local reference intervals for clinical care and trials in Africa.

  17. Low incidence but poor prognosis of complicated coeliac disease: a retrospective multicentre study.

    PubMed

    Biagi, Federico; Gobbi, Paolo; Marchese, Alessandra; Borsotti, Edoardo; Zingone, Fabiana; Ciacci, Carolina; Volta, Umberto; Caio, Giacomo; Carroccio, Antonio; Ambrosiano, Giuseppe; Mansueto, Pasquale; Corazza, Gino R

    2014-03-01

    Coeliac disease is a chronic enteropathy characterized by an increased mortality caused by its complications, mainly refractory coeliac disease, small bowel carcinoma and abdominal lymphoma. Aim of the study was to study the epidemiology of complications in patients with coeliac disease. Retrospective multicenter case-control study based on collection of clinical and laboratory data. The incidence of complicated coeliac disease was studied among coeliac patients directly diagnosed in four Italian centres. Patients referred to these centres after a diagnosis of coeliac disease and/or complicated coeliac disease in other hospitals were therefore excluded. Between 1/1999 and 10/2011, 1840 adult coeliac patients were followed up for 7364.3 person-years. Fourteen developed complications. Since five patients died, at the end of the observation period (10/2011), the prevalence of complicated coeliac disease was 9/1835 (1/204, 0.49%, 95% CI 0.2-0.9%). The annual incidence of complicated coeliac disease in the study period was 14/7364 (0.2%, 95% CI 0.1-0.31%). Although complications tend to occur soon after the diagnosis of coeliac disease, Kaplan-Meier curve analysis showed that they can actually occur at any time after the diagnosis of coeliac disease. Complications of coeliac disease in our cohort were quite rare, though characterised by a very high mortality. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Multicentre physiological reference intervals for serum concentrations of immunoglobulins A, G and M, complement C3c and C4 measured with Tina-Quant reagents systems.

    PubMed

    Fuentes-Arderiu, Xavier; Alonso-Gregorio, Eduardo; Alvarez-Funes, Virtudes; Ambrós-Marigómez, Carmen; Coca-Fábregas, Lluís; Cruz-Placer, Marta; Díaz-Fernández, Julián; Pinel-Julián, María Pilar; Gutiérrez-Cecchini, Beatriz; Herrero-Bernal, Pilar; Sempere-Alcocer, Marcos; García-Caballero, Francisca; Del Mar Larrea-Ortiz-Quintana, María; La-Torre-Marcellán, Pedro; Del Señor López-Vélez, María; Mar-Medina, Carmen; Martín-Oncina, Javier; Rodríguez-Hernández, María Victoria; Romero-Sotomayor, María Victoria; Serrano-López, Cándido; Sicilia-Enríquez-de-Salamanca, Adolfo; Velasco-Romero, Ana María; Juvé-Cuxart, Santiago

    2007-01-01

    Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals. A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.

  19. [Hyperkalemia - what the general practitioner must know].

    PubMed

    Schnyder, Aurelia; Hüsler, Carina; Binet, Isabelle

    2015-03-25

    Hyperkalemia can be a challenge for the general practitioner as it can prove to be benign as well as life-threatening. From a diagnostic point of view, four possibilities have to be differenciated: a pre-analytical cause, potassium release through cell lysis, a potassium shift, a reduced renal excretion of potassium. The first differential diagnosis can often be carried out by a thorough medical history, in particular the medication intake. Also, the first clinical and laboratory investigations can take place at the general practitioner's clinic. If the hyperkalemia proves to be a true hyperkalemia or cannot be explained by poly-medication and known diseases of the patient, not yet identified renal, endocrine or cardiac diseases should be searched for. If a serious condition is identified as the cause of hyperkalemia the patient should be referred to a specialized clinic.

  20. Analysis of Thiodiglycol: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for the analysis of thiodiglycol, the breakdown product of the sulfur mustard HD, in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS777 (hereafter referred to as EPA CRL SOP MS777). This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to verifymore » the analytical procedures described in MS777 for analysis of thiodiglycol in aqueous samples. The gathered data from this study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS777 can be determined.« less

  1. MALDI-TOF MS for identification of Tsukamurella species: Tsukamurella tyrosinosolvens as the predominant species associated with ocular infections.

    PubMed

    Teng, Jade L L; Tang, Ying; Wong, Samson S Y; Fong, Jordan Y H; Zhao, Zhe; Wong, Chun-Pong; Chen, Jonathan H K; Ngan, Antonio H Y; Wu, Alan K L; Fung, Kitty S C; Que, Tak-Lun; Lau, Susanna K P; Woo, Patrick C Y

    2018-05-09

    Although Tsukamurella infections have been increasingly reported in Europe, Asia, America, and Africa, indicating that diseases caused by this group of bacteria are emerging in a global scale, species identification within this genus is difficult in most clinical microbiology laboratories. Recently, we showed that groEL gene sequencing is useful for identification of all existing Tsukamurella species. Nevertheless, PCR sequencing is still considered expensive, time-consuming, and technically demanding, and therefore is yet to be incorporated as a routine identification method in clinical laboratories. Using groEL gene sequencing as the reference method, 60 Tsukamurella isolates were identified as five different Tsukamurella species [T. tyrosinosolvens (n = 31), T. pulmonis (n = 25), T. hongkongensis (n = 2), T. strandjordii (n = 1), and T. sinensis (n = 1)]. The most common source of the patient isolates were the eye (n = 18), sputum (n = 6), and blood (n = 6). None of the 60 isolates were identified correctly to species level by MALDI-TOF MS with the original Bruker database V.6.0.0.0. Using the Bruker database extended with 15 type and reference strains which covered all the currently recognized 11 Tsukamurella species, 59 of the 60 isolates were correctly identified to the species level with score ≥2.0. MALDI-TOF MS should be useful for routine species identification of Tsukamurella in clinical microbiology laboratories after optimization of the database. T. tyrosinosolvens was the most common species observed in patients with Tsukamurella infections and the predominant species associated with ocular infections.

  2. Measurement Challenges at Low Blood Lead Levels.

    PubMed

    Caldwell, Kathleen L; Cheng, Po-Yung; Jarrett, Jeffery M; Makhmudov, Amir; Vance, Kathryn; Ward, Cynthia D; Jones, Robert L; Mortensen, Mary E

    2017-08-01

    In 2012, the Centers for Disease Control and Prevention (CDC) adopted its Advisory Committee on Childhood Lead Poisoning Prevention recommendation to use a population-based reference value to identify children and environments associated with lead hazards. The current reference value of 5 μg/dL is calculated as the 97.5th percentile of the distribution of blood lead levels (BLLs) in children 1 to 5 years old from 2007 to 2010 NHANES data. We calculated and updated selected percentiles, including the 97.5th percentile, by using NHANES 2011 to 2014 blood lead data and examined demographic characteristics of children whose blood lead was ≥90th percentile value. The 97.5th percentile BLL of 3.48 µg/dL highlighted analytical laboratory and clinical interpretation challenges of blood lead measurements ≤5 μg/dL. Review of 5 years of results for target blood lead values <11 µg/dL for US clinical laboratories participating in the CDC's voluntary Lead and Multi-Element Proficiency quality assurance program showed 40% unable to quantify and reported a nondetectable result at a target blood lead value of 1.48 µg/dL, compared with 5.5% at a target BLL of 4.60 µg/dL. We describe actions taken at the CDC's Environmental Health Laboratory in the National Center for Environmental Health, which measures blood lead for NHANES, to improve analytical accuracy and precision and to reduce external lead contamination during blood collection and analysis. Copyright © 2017 by the American Academy of Pediatrics.

  3. Outcome of Chronic Kidney Disease Patients on the Basis of Referral to Nephrologist: A One-Year Follow-up Study.

    PubMed

    Anees, Muhammad; Hussain, Yasir; Ibrahim, Muhammad; Ilahi, Irfan; Ahmad, Sajjad; Asif, Khushbakht Isma; Jameel, Amina

    2018-04-01

    To determine the outcome of chronic kidney disease (CKD) patients presenting for dialysis on the basis of referral to nephrologist. Observational study. Nephrology Department of King Edward Medical University/Mayo Hospital, Lahore, from January 2014 to January 2016. All patients who were presented in nephrology outpatients department and with the indication of dialysis were included in study. Patients who refused dialysis, and with acute kidney failure were excluded from the study. Proforma was designed for demographics, vital signs, volume status, and laboratory data (hemoglobin, urea, creatinine, albumin, bicarbonate etc.) of all the patients. On the basis of referral, patients were divided into two groups, i.e. early referral and late referral. Early referrals were those patients who were referred to a nephrologist more than three months before dialysis initiation. Late referrals were those patients who were referred to a nephrologist less than three months before dialysis initiation. Patients were followed up at one, three, six, and 12 months for outcome, i.e. still on dialysis or died. One hundred and seventy-six patients were enrolled in the study, and 141 were followed up to one year. Seventy- two (51.1%) patients were male, 69 (48.9%) were female and most (n=69, 48.9%) were in the middle age group. Major causes of end-stage renal disease (ESRD) were hypertension 70 (49.6%) and diabetes mellitus 66 (46.8%). Seventy-six (53.9%) patients were in fluid overload and acidotic (n=123, 87.2%). Twenty-seven (19.1%) patients were referred early and 114 (80.9%) were referred late. Overall mortality was 78 (55.3%) at one year. Factors affecting mortality were financial status and metabolic acidosis, but not referral. Temporary access for hemodialysis has 1.38 times more risk for mortality than the patients with permanent access. There is no difference on the outcome of dialysis patients on the basis referral to nephrologist. Factors affecting overall mortality in both groups were financial status, metabolic acidosis, and temporary access for dialysis. Most of the patients were referred late to the nephrologists.

  4. [Quality assessment of microscopic examination in tuberculosis diagnostic laboratories: a preliminary study].

    PubMed

    Simşek, Hülya; Ceyhan, Ismail; Tarhan, Gülnur; Güner, Uğur

    2010-10-01

    Recently, the diagnosis of pulmonary tuberculosis (TB) has based on smear microscopy in the Direct Observed Treatment Strategy (DOTS) programme which provides the basis of treatment worldwide. Microscopic detection of AFB (Acid-Fast Bacilli) is one of the main components in the National TB Control Programmes (NTCP). Precision level in microscopy procedures and evaluations are the most important steps for accurate diagnosis of the disease and to initiate proper treatment. Therefore, the external quality assessment (EQA) is the most important implement to provide the reliability and validity of tests. In countries where NTCP are performed, this task is fulfilled by the National Reference Laboratories (NRL) according to the guidelines of the World Health Organization (WHO). For this purpose a pilot study was initiated by the central NRL of Turkey for EQA of AFB smear microscopy as part of the NTCP on January 1, 2005. A total of 5 laboratories of which 2 were district TB laboratories (A, B), 2 were tuberculosis control dispensaries (C, D), 1 was a national reference laboratory (E), participated in this study. Blind re-checking method (re-examination of randomly selected slides) was used for the evaluation, and the slides were sent to the central NRL with 3 months interval, four times a year, selected according to LQAS (Lot Quality Assurance Sampling) guides. In the re-evaluation of the slides, false positivity (FP), false negativity (FN) and quantification errors (QE) were noted. Laboratory A, sent totally 525 slides between January 1, 2005 and April 1, 2008. In the result of re-checking, 514 (97.9%) slides were found concordant, and 11 (2.1%) were discordant (10 FP, 1 FN). Laboratory B, participated in the study between October 1, 2005 and July 1, 2006 and of the 67 re-examined slides, 60 (89.5%) were concordant and 7 (10.5%) were discordant (2 FP, 0 FN, 5 QE). Laboratory C, sent 235 slides between January 1, 2005 and April 1, 2006; of them 218 (92.8%) were detected as compatible and 17 (7.2%) slides were incompatible (4 FP, 9 FN, 4 QE). Laboratory D, participated in QC for only once between January 1, 2008 and April 1, 2008; and all the 50 slides were found compatible, with no FP, FN and QE. Laboratory E, was included in the study between January 1, 2005 and January 1, 2008 and of the 696 re-checked slides, 690 (99.1%) were reported as compatible and 6 (0.9%) were incompatible (3 FN, 3 QE). Following EQA, on-site evaluation of the laboratories with major errors, was performed and necessary adjustments and training were done. In conclusion, external quality control measures for AFB microscopy is crucial and essential for the tuberculosis laboratory performances for accurate and reliable results.

  5. Internal validation of the DNAscan/ANDE™ Rapid DNA Analysis™ platform and its associated PowerPlex® 16 high content DNA biochip cassette for use as an expert system with reference buccal swabs.

    PubMed

    Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F

    2017-07-01

    Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.

  6. Monitoring and investigating natural disease by veterinary pathologists in diagnostic laboratories.

    PubMed

    O'Toole, D

    2010-01-01

    Many emerging diseases in animals are initially recognized by diagnostic pathologists in animal health laboratories using routine laboratory submissions, in conjunction with clinical veterinarians and wildlife biologists. Familiar recent examples are chronic wasting disease, bovine spongiform encephalopathy, West Nile encephalomyelitis in North America, and postweaning multisystemic wasting syndrome in pigs. The recognition of new diseases in animals requires that the curiosity of diagnosticians be articulated with the capacity of animal health laboratories to create effective diagnostic teams, solicit additional cases from the field at minimal cost to clients, and develop relationships with basic researchers. Bovine neosporosis is used as an example to illustrate how a disease investigation triggered by routine clinical accessions can have international ramifications. Between the late 1980s and 1995, diagnosticians with California's animal health laboratory system identified neosporosis as a cause of reproductive wastage in cattle, characterized the lesions, isolated the agent, defined routes of transmission, met Koch's postulates, and developed diagnostic assays. Diagnostic pathologists catalyzed the process. The neosporosis investigation in California suggests useful attributes of veterinary diagnostic laboratories that pursue emerging diseases identified through routine laboratory accessions.

  7. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for fast and accurate identification of clinically relevant Aspergillus species.

    PubMed

    Alanio, A; Beretti, J-L; Dauphin, B; Mellado, E; Quesne, G; Lacroix, C; Amara, A; Berche, P; Nassif, X; Bougnoux, M-E

    2011-05-01

    New Aspergillus species have recently been described with the use of multilocus sequencing in refractory cases of invasive aspergillosis. The classical phenotypic identification methods routinely used in clinical laboratories failed to identify them adequately. Some of these Aspergillus species have specific patterns of susceptibility to antifungal agents, and misidentification may lead to inappropriate therapy. We developed a matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS)-based strategy to adequately identify Aspergillus species to the species level. A database including the reference spectra of 28 clinically relevant species from seven Aspergillus sections (five common and 23 unusual species) was engineered. The profiles of young and mature colonies were analysed for each reference strain, and species-specific spectral fingerprints were identified. The performance of the database was then tested on 124 clinical and 16 environmental isolates previously characterized by partial sequencing of the β-tubulin and calmodulin genes. One hundred and thirty-eight isolates of 140 (98.6%) were correctly identified. Two atypical isolates could not be identified, but no isolate was misidentified (specificity: 100%). The database, including species-specific spectral fingerprints of young and mature colonies of the reference strains, allowed identification regardless of the maturity of the clinical isolate. These results indicate that MALDI-TOF MS is a powerful tool for rapid and accurate identification of both common and unusual species of Aspergillus. It can give better results than morphological identification in clinical laboratories. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  8. They See a Rat, We Seek a Cure for Diseases: The Current Status of Animal Experimentation in Medical Practice

    PubMed Central

    Kehinde, Elijah O.

    2013-01-01

    The objective of this review article was to examine current and prospective developments in the scientific use of laboratory animals, and to find out whether or not there are still valid scientific benefits of and justification for animal experimentation. The PubMed and Web of Science databases were searched using the following key words: animal models, basic research, pharmaceutical research, toxicity testing, experimental surgery, surgical simulation, ethics, animal welfare, benign, malignant diseases. Important relevant reviews, original articles and references from 1970 to 2012 were reviewed for data on the use of experimental animals in the study of diseases. The use of laboratory animals in scientific research continues to generate intense public debate. Their use can be justified today in the following areas of research: basic scientific research, use of animals as models for human diseases, pharmaceutical research and development, toxicity testing and teaching of new surgical techniques. This is because there are inherent limitations in the use of alternatives such as in vitro studies, human clinical trials or computer simulation. However, there are problems of transferability of results obtained from animal research to humans. Efforts are on-going to find suitable alternatives to animal experimentation like cell and tissue culture and computer simulation. For the foreseeable future, it would appear that to enable scientists to have a more precise understanding of human disease, including its diagnosis, prognosis and therapeutic intervention, there will still be enough grounds to advocate animal experimentation. However, efforts must continue to minimize or eliminate the need for animal testing in scientific research as soon as possible. PMID:24217224

  9. They see a rat, we seek a cure for diseases: the current status of animal experimentation in medical practice.

    PubMed

    Kehinde, Elijah O

    2013-01-01

    The objective of this review article was to examine current and prospective developments in the scientific use of laboratory animals, and to find out whether or not there are still valid scientific benefits of and justification for animal experimentation. The PubMed and Web of Science databases were searched using the following key words: animal models, basic research, pharmaceutical research, toxicity testing, experimental surgery, surgical simulation, ethics, animal welfare, benign, malignant diseases. Important relevant reviews, original articles and references from 1970 to 2012 were reviewed for data on the use of experimental animals in the study of diseases. The use of laboratory animals in scientific research continues to generate intense public debate. Their use can be justified today in the following areas of research: basic scientific research, use of animals as models for human diseases, pharmaceutical research and development, toxicity testing and teaching of new surgical techniques. This is because there are inherent limitations in the use of alternatives such as in vitro studies, human clinical trials or computer simulation. However, there are problems of transferability of results obtained from animal research to humans. Efforts are on-going to find suitable alternatives to animal experimentation like cell and tissue culture and computer simulation. For the foreseeable future, it would appear that to enable scientists to have a more precise understanding of human disease, including its diagnosis, prognosis and therapeutic intervention, there will still be enough grounds to advocate animal experimentation. However, efforts must continue to minimize or eliminate the need for animal testing in scientific research as soon as possible. © 2013 S. Karger AG, Basel.

  10. Could Buerger's disease cause nonarteritic anterior ischemic optic neuropathy?: a rare case report.

    PubMed

    Korkmaz, Anil; Karti, Omer; Top Karti, Dilek; Yüksel, Bora; Zengin, Mehmet Ozgur; Kusbeci, Tuncay

    2018-04-05

    We present an interesting case with nonarteritic anterior ischemic optic neuropathy (NAION) accompanied by Buerger's disease. A 43-year-old man was referred to our neuro-ophthalmology clinic with a complaint of visual deterioration in the left eye that started 5 days ago. He suffered from Buerger's disease, and he had acute pain in the right lower limb below the knee. His best corrected visual acuity was 10/10 in the right eye and 2/10 in the left eye by Snellen chart. There was a relative afferent pupil defect in the left eye. The right optic disc was normal on fundus examination, and blurring, hemorrhagic swelling was found at the left optic disc. Inferior altitudinal visual field defect was observed in the left eye. Neurological examination was normal. Computed tomography angiography scan revealed occlusion in the right posterior tibial artery. Brain imaging and laboratory tests such as blood analyses, genetic screening, coagulation, and lipid panels were unremarkable. NAION may occur in patients with Buerger's disease, but it is extremely rare. Therefore, clinicians should be aware of this rare association.

  11. B-Flow Imaging in Lower Limb Peripheral Arterial Disease and Bypass Graft Ultrasonography.

    PubMed

    D'Abate, Fabrizio; Ramachandran, Veni; Young, Mark A; Farrah, John; Ahmed, Mudasar H; Jones, Keith; Hinchliffe, Robert J

    2016-09-01

    Doppler ultrasonography plays a key role in the diagnosis of peripheral arterial disease, but is often limited by pitfalls that may be overcome by B-flow imaging. Thus far, there is little information on B-flow imaging for the assessment of peripheral arterial disease and bypass grafts in lower limbs. This article describes the authors' early experience with B-flow in the lower extremities. Sixty patients were included among a large cohort of patients routinely referred to the vascular laboratory for peripheral arterial disease and bypass graft assessments. Two experienced vascular sonographers performed all scans, comparing color Doppler ultrasonography with B-flow imaging. All scans were performed using a combination of the 9 L linear and C2-9 curvilinear transducers with the LOGIQ E9 system (GE Healthcare, Waukesha, WI, USA). Our experience indicates that this relatively unexplored technology has the potential to significantly improve peripheral blood flow evaluation. Nevertheless, B-flow imaging is not exempt from limitations and should be considered complementary to color Doppler ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. [Exploration of microcosmic Chinese medicine used by western medicine].

    PubMed

    Zheng, Zhi-jing

    2015-02-01

    "Microcosmic syndrome", "treatment based on syndrome differentiation", and "combination of disease identification and syndrome differentiation" generally refer to a mode: following the syndrome if with no disease identified, following the disease if with no syndrome type differentiated. For example, Chinese medical treatment of hypertension, high blood lipids, increased transaminase, and so on candirectly use Chinese recipes, but no longer with syndrome differentiation. Clinical application of Chinese patent medicine can also obtain favorable clinical. Western doctors need not follow syndrome differentiation. The invention of artemisinin was screened from more than 40 000 kinds of compounds and herbs, but with no reference of any traditional Chinese medical theory. A lot of folk remedy and empirical recipes have obtained effective efficacy but unnecessarily with profound Chinese medical theories. Various evidences showed that disease can also be cured without syndrome differentiation. I held that it might be associated with the same mechanism of Chinese medicine and Western medicine. Any disease can be cured or alleviated by Chinese medicine is a result from its modern pharmacological effect, which is achieved by improving etiologies, and pathogeneses. I was inspired by whether we can directly use traditional Chinese medicine with modern pharmacological effects to treat symptomatic disease. So I raised an idea of microcosmic Chinese medicine used by Western medicine, i.e., we find and use Chinese herbs with relatively effective modern pharmacological effect to treat diseases targeting at patients' clinical symptoms and signs, as well as various positive laboratory results (collectively called as microscopic dialectical indicators). More Western doctors would use it to treat disease due to omission of complicated and mysterious syndrome differentiation. This will promote extensive application and expansion of Chi- nese medicine and pharmacy, enlarge the team of integrative medicine, improve Western doctors' interest in Chinese medicine and pharmacy, thus pushing the career of integrative medicine in a brand new development era.

  13. Diagnostic Testing and Interpretation of Tests for Autoimmunity

    PubMed Central

    Castro, Christine; Gourley, Mark

    2010-01-01

    Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. This chapter discusses these components and includes a discussion about organ-specific immunologic diseases where immunological laboratory testing is employed. Comprehensive laboratory evaluation of a suspected autoimmune illness in conjunction with a thorough clinical evaluation provides a better understanding of a patient's immunologic disease. PMID:20061009

  14. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology.

    PubMed

    Bohannon, J Kyle; Janosko, Krisztina; Holbrook, Michael R; Barr, Jason; Pusl, Daniela; Bollinger, Laura; Coe, Linda; Hensley, Lisa E; Jahrling, Peter B; Wada, Jiro; Kuhn, Jens H; Lackemeyer, Matthew G

    2016-10-03

    Aerosol or inhalational studies of high-consequence pathogens have recently been increasing in number due to the perceived threat of intentional aerosol releases or unexpected natural aerosol transmission. Specific laboratories designed to perform these experiments require tremendous engineering controls to provide a safe and secure working environment and constant systems maintenance to sustain functionality. Class III biosafety cabinets, also referred to as gloveboxes, are gas-tight enclosures with non-opening windows. These cabinets are maintained under negative pressure by double high-efficiency-particulate-air (HEPA)-filtered exhaust systems and are the ideal primary containment for housing aerosolization equipment. A well planned workflow between staff members within high containment from, for instance, an animal biosafety level-4 (ABSL-4) suit laboratory to the ABSL-4 cabinet laboratory is a crucial component for successful experimentation. For smooth study execution, establishing a communication network, moving equipment and subjects, and setting up and placing equipment, requires staff members to meticulously plan procedures prior to study initiation. Here, we provide an overview and a visual representation of how aerobiology research is conducted at the National Institutes of Health, National Institute of Allergy and Infectious Diseases Integrated Research Facility at Fort Detrick, Maryland, USA, within an ABSL-4 environment.

  15. [Study of quality of a branch laboratory--an opinion of a laboratory manager].

    PubMed

    Yazawa, Naoyuki

    2006-11-01

    At the stage of establishing a branch laboratory, quality evaluation is extremely difficult. Even the results of a control survey by the headquarters of the branch laboratory are unhelpful. For a clinical laboratory, the most important function is to provide reliable data all the time, and to maintain the reliability of clinical doctors with informed responses. We mostly refer to control surveys and daily quality control data to evaluate a clinical laboratory, but we rarely check its fundamental abilities, such as planning events, preserving statistical data about the standard range, using the right method for quality control and others. This is generally disregarded and it is taken for granted that they will be correct the first time. From my six years of experience working with X's branch laboratory, I realized that there might be some relation between the quality of a branch laboratory and the fundamental abilities of the company itself. I would never argue that all branch laboratories are ineffective, but they should be conscious of fundamental activities. The referring laboratory, not the referral laboratory, should be responsible for ensuring that the referral laboratory's examination results and findings are correct.

  16. Malaria and other febrile diseases among travellers: the experience of a reference centre located outside the Brazilian Amazon Region.

    PubMed

    Dotrário, Andréa Beltrami; Menon, Lucas José Bazzo; Bollela, Valdes Roberto; Martinez, Roberto; de Almeida E Araújo, Daniel Cardoso; da Fonseca, Benedito Antônio Lopes; Santana, Rodrigo de C

    2016-05-26

    Malaria is endemic in countries located in tropical and sub-tropical regions. The increasing flow of domestic and international travellers has made malaria a relevant health problem even in non-endemic regions. Malaria has been described as the main diagnosis among travellers presenting febrile diseases after returning from tropical countries. In Brazil, malaria transmission occurs mainly in the Amazon region. Outside this area, malaria transmission is of low magnitude. This cross-sectional study aimed to describe the experience in the diagnosis of malaria in a reference centre located outside the Brazilian Amazon Region, emphasizing the differences in clinical and laboratory markers between cases of malaria and those of other febrile diseases (OFD). Medical charts from adult patients (≥18 years) who underwent a thick smear test (TST) for malaria, between January 2001 and December 2014, were retrospectively reviewed. A total of 458 cases referred to perform the TST were included. Malaria was diagnosed in 193 (42 %) episodes. The remaining 265 episodes (58 %) were grouped as OFD. The majority of malaria episodes were acquired in the Brazilian Amazon Region. The median time between the onset of symptoms and the TST was 7 days. Only 53 (11.5 %) episodes were tested within the first 48 h after symptom onset. Comparing malaria with OFD, jaundice, nausea, vomiting, and reports of fever were more prevalent in the malaria group. Low platelet count and elevated bilirubin levels were also related to the diagnosis of malaria. The results indicate that outside the endemic area travellers presenting febrile disease suspected of being malaria underwent diagnostic test after considerable delay. The reporting of fever combined with a recent visit to an endemic area should promptly evoke the hypothesis of malaria. In these cases, specific diagnostic tests for malaria should be a priority. For cases that jump this step, the presence of elevated bilirubin or thrombocytopaenia should also indicate a diagnosis of malaria.

  17. Exercise and the Athlete With Infectious Mononucleosis.

    PubMed

    Shephard, Roy J

    2017-03-01

    To determine appropriate management of the active individual with infectious mononucleosis (IM), including issues of diagnosis, the determination of splenomegaly, and other measures of disease status, the relationship of the disease to chronic fatigue syndrome (CFS), and the risks of exercise at various points in the disease process. An Ovid/MEDLINE search (January 1996-June 2015) was widely supplemented by "similar articles" found in Ovid/MEDLINE and PubMed, reference lists, and personal files. Clinical diagnoses of IM are unreliable. Traditional laboratory indicators (lymphocytosis, abnormal lymphocytes, and a heterophile-positive slide test) can be supplemented by more sensitive and more specific but also more costly Epstein-Barr antigen determinations. Clinical estimates of splenomegaly are fallible. Laboratory determinations, commonly by 2D ultrasonography, must take account of methodology, the formulae used in calculations and the individual's body size. The SD of normal values matches the typical increase of size in IM, but repeat measurements can help to monitor regression of the disease. The main risks to the athlete are spontaneous splenic rupture (seen in 0.1%-0.5% of patients and signaled by acute abdominal pain) and progression to chronic fatigue, best avoided by 3 to 4 weeks of restricted activity followed by graded reconditioning. A full recovery of athletic performance is usual with 2 to 3 months of conservative management. Infectious mononucleosis is a common issue for young athletes. But given accurate diagnosis and the avoidance of splenic rupture and progression to CFS through a few weeks of restricted activity, long-term risks to the health of athletes are few.

  18. Mining of hospital laboratory information systems: a model study defining age- and gender-specific reference intervals and trajectories for plasma creatinine in a pediatric population.

    PubMed

    Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen

    2015-09-01

    The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.

  19. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  20. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  1. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  2. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  3. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  4. Completeness and timeliness of electronic vs. conventional laboratory reporting for communicable disease surveillance--Oklahoma, 2011.

    PubMed

    Johnson, Matthew G; Williams, Jean; Lee, Anthony; Bradley, Kristy K

    2014-05-01

    The Health Information Technology for Economic and Clinical Health (HITECH) Act encourages the meaningful use of certified electronic health record technology. A HITECH-compliant core component is nationwide electronic laboratory reporting (ELR) implementation for communicable disease surveillance. In Oklahoma, laboratories with ≥400 positive tests/year for reportable diseases must use ELR. Of 18 such laboratories, two have adopted ELR. We compared completeness and timeliness of ELR reports from these two laboratories with conventional reports from all other Oklahoma laboratories. We retrospectively reviewed confirmed reportable disease cases for January 1-December 31, 2011, excluding tuberculosis, hepatitis, sexually transmitted infections, diseases without laboratory diagnoses, and immediately reportable diseases. Probable reportable tickborne disease cases were included. We compared ELR with conventional reporting (i.e., mail, fax, telephone, and Internet). We assessed data completeness based on eight demographic and two laboratory fields in each disease report and timeliness by percentage of cases reported in ≤1 business day. Overall, 1,867 reports met the inclusion criteria; 24% of these reports had been submitted by ELR. Data completeness was 90% for ELR and 95% for conventional reporting. Patient addresses accounted for 97% of the missing data fields for ELR reports. Timeliness was 91% for ELR and 87% for conventional reports. Although early in the transition to ELR compliance in Oklahoma, ELR has already yielded improved timeliness for communicable disease surveillance. However, ELR did not yield more complete reports than conventional reporting. Requiring specific demographic data fields for ELR reports can improve the completeness of ELR.

  5. [Surveillance on other infectious diarrheal diseases in China from 2014 to 2015].

    PubMed

    Zhang, P; Zhang, J

    2017-04-10

    Objective: To analyze the current situation on infectious diarrhea other than cholera, dysentery, typhoid and paratyphoid (hereinafter referred to as Other Infectious Diarrheal Diseases) under the current monitoring program in China from 2014 to 2015, to provide evidence for developing strategies related to the control of these diseases. Methods: All the reported infectious diarrhea cases and information on public health emergencies relevant to infectious diarrhea were collected from the "Chinese Information System for Disease Control and Prevention" . Analytic method was carried out to describe the etiological and epidemiological characteristics of all the infectious diarrhea cases. Results: In 2014, a total of 867 545 infectious diarrhea cases were reported, with the incidence rate as 64.0/100 000. While in 2015, a total of 937 616 infectious diarrhea cases were reported, and the incidence rate was 68.8/100 000. Cases distributed in all provinces of the country, with incidence rates between 3.8/100 000 and 506.7/100 000. Cases involved in all the age groups, with 53.7 % (968 984/1 805 161) of the total reported cases below 5 years of age. Reported cases showed two peaks of incidence, in summer (from June to August) and winter (from November to next January). Laboratory-confirmed cases accounted for 9.5 % (82 285/867 545) of the total and 9.3 % (86 975/937 616) of the cases reported in 2014 and 2015 respectively. Among cases reported in the two years, viral infection accounted for 92.4 % (76 045/82 285) and 91.0 % (79 176/86 975) while bacterial infection accounted for 7.4 % (6 062/82 285) and 8.8 % (7 614/86 975), respectively. Among the death cases, only three were laboratory confirmed, with two of them caused by rotavirus. Conclusions: Children under 5 years old appeared both higher incidence and mortalities for infectious diarrhea. Most laboratory-confirmed cases were viral-born, with pathogenic spectrums varied in different provinces. Capabilities related to testing and case-reporting on infectious diarrheal diseases differed greatly among areas that called for urgent improvement.

  6. Optical-Fiber Power Meter Comparison between NIST and KRISS.

    PubMed

    Vayshenker, I; Kim, S K; Hong, K; Lee, D-H; Livigni, D J; Li, X; Lehman, J H

    2012-01-01

    We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Korea Research Institute of Standards and Science (KRISS-R.O. Korea) for optical fiber-based power measurements at wavelengths of 1302 nm and 1546 nm. We compare the laboratories' reference standards by means of a temperature-controlled optical trap detector. Measurement results showed the largest difference of less than 2.5 parts in 10(3), which is within the combined standard (k=1) uncertainty for the two laboratories' reference standards.

  7. Optical-Fiber Power Meter Comparison Between NIST and PTB.

    PubMed

    Vayshenker, I; Haars, H; Li, X; Lehman, J H; Livigni, D J

    2003-01-01

    We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Physikalisch-Technische Bundesanstalt (PTB-Germany) at nominal wavelengths of 1300 nm and 1550 nm using an optical-fiber cable. Both laboratories used thermal detectors as reference standards. A novel temperature-controlled, optical-trap detector was used as a transfer standard to compare two reference standards. Measurement results showed differences of less than 1.5 × 10(-3), which is within the combined uncertainty for both laboratories.

  8. Watery diarrhea, hypokalemia and achlorhydria syndrome due to an adrenal pheochromocytoma

    PubMed Central

    Ikuta, Shin-ichi; Yasui, Chiaki; Kawanaka, Masahiro; Aihara, Tsukasa; Yoshie, Hidenori; Yanagi, Hidenori; Mitsunobu, Masao; Sugihara, Ayako; Yamanaka, Naoki

    2007-01-01

    Watery diarrhea, hypokalemia and achlorhydria (WDHA) syndrome caused by vasoactive intestinal polypeptide (VIP) -producing tumor only rarely occurs in patients with nonpancreatic disease. A 49-year-old woman was referred for evaluation of a right adrenal tumor incidentally diagnosed by abdominal ultrasound during the investigation of chronic watery diarrhea. Laboratory findings showed hypokalemia and excessive production of VIP and catecholamines. After surgical resection of the tumor, diarrhea subsided and both electrolytes and affected hormone levels normalized. Immunohistochemical examination confirmed a diagnosis of pheochromocytoma, which contained VIP-positive ganglion-like cells. We herein present the clinical and histogenetic implications of this rare clinical entity, with literature review. PMID:17729424

  9. Diagnosing schistosomiasis: where are we?

    PubMed

    Gomes, Luciana Inácia; Enk, Martin Johannes; Rabello, Ana

    2014-01-01

    In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.

  10. Somatotype and disease prevalence in adults.

    PubMed

    Koleva, M; Nacheva, A; Boev, M

    2002-01-01

    We examined the association between the somatotype and its main components (endomorphy, mesomorphy and ectomorphy), and the prevalence of several chronic diseases. The data were obtained from a cross-sectional survey designed to assess somatotype and morbidity with special reference to most often diagnosed diseases. The study population comprised 524 men and 250 women. The subjects underwent laboratory tests and clinical and anthropometric examinations. Of all examined workers, 94.8% fell into the five somatotype categories; of these, 394 were endomorphic mesomorphs. The most common somatotype was endomorphic mesomorph for men and mesomorph-endomorph for women. In five disease groups, prevalence was significantly related to a somatotype. Mesomorphic endomorphs most frequently suffered from digestive system diseases (40.6%, p < 0.05), neuroses (30.1%, p < 0.05), and radiculitis lumbosacralis (15.4%). The prevalence of arterial hypertension in mesomorph-endomorphs (37.1%), endomorphic mesomorphs (35.5%), and mesomorphic endomorphs (34.3%) was equal. In both genders, those with the highest endomorphy and mesomorphy and the lowest ectomorphy, grouped by cluster analysis, were those who suffered most frequently from arterial hypertension and liver disease. The authors conclude that the somatotype having a dominant mesomorphy and marked endomorphy constitutes a risk factor as a particular predisposition toward certain diseases and requires body weight control.

  11. Clinical pathology accreditation: standards for the medical laboratory

    PubMed Central

    Burnett, D; Blair, C; Haeney, M R; Jeffcoate, S L; Scott, K W M; Williams, D L

    2002-01-01

    This article describes a new set of revised standards for the medical laboratory, which have been produced by Clinical Pathology Accreditation (UK) Ltd (CPA). The original standards have been in use since 1992 and it was recognised that extensive revision was required. A standards revision group was established by CPA and this group used several international standards as source references, so that the resulting new standards are compatible with the most recent international reference sources. The aim is to make the assessment of medical laboratories as objective as possible in the future. CPA plans to introduce these standards in the UK in 2003 following extensive consultation with professional bodies, piloting in selected laboratories, and training of assessors. PMID:12354795

  12. Do Graduate Teaching Assistants Benefit from Teaching Inquiry-Based Laboratories?

    ERIC Educational Resources Information Center

    French, Donald; Russell, Connie

    2002-01-01

    Introduces a study investigating graduate teaching assistants' (GTA) perceptions on their role in conducting laboratories and explores the benefits of inquiry-based laboratories for GTAs considering their experiences and knowledge. (Contains 22 references.) (YDS)

  13. Aligning Perceptions of Laboratory Demonstrators' Responsibilities to Inform the Design of a Laboratory Teacher Development Program

    ERIC Educational Resources Information Center

    Flaherty, Aishling; O'Dwyer, Anne; Mannix-McNamara, Patricia; Leahy, J. J.

    2017-01-01

    Throughout countries such as Ireland, the U.K., and Australia, graduate students who fulfill teaching roles in the undergraduate laboratory are often referred to as "laboratory demonstrators". The laboratory demonstrator (LD) model of graduate teaching is similar to the more commonly known graduate teaching assistant (GTA) model that is…

  14. Development of a reference material for routine performance monitoring of methods measuring polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like polychlorinated biphenyls.

    PubMed

    Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D

    2001-06-01

    Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.

  15. Recent developments in the field of environmental reference materials at the JRC Ispra.

    PubMed

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  16. Age dependency for coagulation parameters in paediatric populations. Results of a multicentre study aimed at defining the age-specific reference ranges.

    PubMed

    Toulon, Pierre; Berruyer, Micheline; Brionne-François, Marie; Grand, François; Lasne, Dominique; Telion, Caroline; Arcizet, Julien; Giacomello, Roberta; De Pooter, Neila

    2016-07-04

    Understanding of developmental haemostasis is critical to ensure optimal prevention, diagnosis, and treatment of haemorrhagic and thrombotic diseases in children. As coagulation test results are known to be dependent on the reagents/analysers used, it is recommended for each laboratory to define the age-dependent reference ranges by using its own technical condition. That study was carried out in seven centers to establish age-specific reference ranges using the same reagents and analyser. Plasma samples were obtained from 1437 paediatric patients from the following age groups: 15 days-4 weeks (n=36), 1-5 months (n=320), 6-12 months (n=176), 1-5 years (n=507), 6-10 years (n=132) and 11-17 years (n=262). Indication of coagulation testing was pre-operative screening for non-acute diseases in most cases. PT values were similar in the different age groups to those in adults, whereas longer aPTTs were demonstrated in the younger children. Plasma levels of all clotting factors, except for FV, were significantly decreased (p<0.0001) in the youngest children, adult values being usually reached before the end of the first year. The same applied to antithrombin, protein C/S, and plasminogen. In contrast, FVIII and VWF levels were elevated in the youngest children and returned to adult values within six months. The same applied to D-dimer levels, which were found elevated, particularly until six months of life, until puberty. These data suggest that most coagulation test results are highly dependent on age, mainly during the first year of life, and that age-specific reference ranges must be used to ensure proper evaluation of coagulation in children.

  17. Impact of a Reference Center on Leprosy Control under a Decentralized Public Health Care Policy in Brazil.

    PubMed

    Barbieri, Raquel Rodrigues; Sales, Anna Maria; Hacker, Mariana Andrea; Nery, José Augusto da Costa; Duppre, Nádia Cristina; Machado, Alice de Miranda; Moraes, Milton Ozório; Sarno, Euzenir Nunes

    2016-10-01

    We evaluated the profile of patients referred to the Fiocruz Outpatient Clinic, a reference center for the diagnosis and treatment of leprosy in Rio de Janeiro, RJ, and analyzed the origins and outcomes of these referrals. This is an observational retrospective study based on information collected from the Leprosy Laboratory database at Fiocruz, Rio de Janeiro, RJ, Brazil. A total of 1,845 suspected leprosy cases examined at the reference center between 2010 and 2014 were included. The originating health service referrals and diagnostic outcomes were analyzed as well as the clinical and epidemiological data of patients diagnosed with leprosy. Our data show that the profile of the patients treated at the Clinic has changed in recent years. There was an increase in both the proportion of patients with other skin diseases and those who had visited only one health service prior to our Clinic. Among the total 1,845 cases analyzed, the outcomes of 1,380 were linked to other diseases and, in 74% of these cases, a biopsy was not necessary to reach a diagnostic conclusion. A decrease in new leprosy case detection among our patients was also observed. Yet, among the leprosy patients, 40% had some degree of disability at diagnosis. The results of the present study demonstrated the importance of referral centers in support of basic health services within the decentralization strategy. But, the success of the program depends on the advent of new developmental tools to augment diagnostic accuracy for leprosy. However, it should be emphasized that for new diagnostic methods to be developed, a greater commitment on the part of the health care system regarding research is urgently needed.

  18. TREAT Asia Quality Assessment Scheme (TAQAS) to standardize the outcome of HIV genotypic resistance testing in a group of Asian laboratories

    PubMed Central

    Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew

    2010-01-01

    The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972

  19. Status, quality and specific needs of Zika virus (ZIKV) diagnostic capacity and capability in National Reference Laboratories for arboviruses in 30 EU/EEA countries, May 2016

    PubMed Central

    Mögling, Ramona; Zeller, Hervé; Revez, Joana; Koopmans, Marion; Reusken, Chantal

    2017-01-01

    With international travel, Zika virus (ZIKV) is introduced to Europe regularly. A country's ability to robustly detect ZIKV introduction and local transmission is important to minimise the risk for a ZIKV outbreak. Therefore, sufficient expertise and diagnostic capacity and capability are required in European laboratories. To assess the capacity, quality, operational specifics (guidelines and algorithms), technical and interpretation issues and other possible difficulties that were related to ZIKV diagnostics in European countries, a questionnaire was conducted among national reference laboratories in 30 countries in the European Union/European Economic Area (EU/EEA) in May 2016. While the coverage and capacity of ZIKV diagnostics in the EU/EEA national reference laboratories were found to be adequate, the assessment of the quality and needs indicated several crucial points of improvement that will need support at national and EU/EEA level to improve ZIKV preparedness, response and EU/EEA ZIKV surveillance activities. PMID:28920574

  20. Reference intervals and physiologic alterations in hematologic and biochemical values of free-ranging desert tortoises in the Mojave Desert

    USGS Publications Warehouse

    Christopher, Mary M.; Berry, Kristin H.; Wallis, I.R.; Nagy, K.A.; Henen, B.T.; Peterson, C.C.

    1999-01-01

    Desert tortoise (Gopherus agassizii) populations have experienced precipitous declines resulting from the cumulative impact of habitat loss, and human and disease-related mortality. Evaluation of hematologic and biochemical responses of desert tortoises to physiologic and environmental factors can facilitate the assessment of stress and disease in tortoises and contribute to management decisions and population recovery. The goal of this study was to obtain and analyze clinical laboratory data from free-ranging desert tortoises at three sites in the Mojave Desert (California, USA) between October 1990 and October 1995, to establish reference intervals, and to develop guidelines for the interpretation of laboratory data under a variety of environmental and physiologic conditions. Body weight, carapace length, and venous blood samples for a complete blood count and clinical chemistry profile were obtained from 98 clinically healthy adult desert tortoises of both sexes at the Desert Tortoise Research Natural area (western Mojave), Goffs (eastern Mojave) and Ivanpah Valley (northeastern Mojave). Samples were obtained four times per year, in winter (February/March), spring (May/June), summer (July/August), and fall (October). Years of near-, above- and below-average rainfall were represented in the 5 yr period. Minimum, maximum and median values, and central 95 percentiles were used as reference intervals and measures of central tendency for tortoises at each site and/or season. Data were analyzed using repeated measures analysis of variance for significant (P < 0.01) variation on the basis of sex, site, season, and interactions between these variables. Significant sex differences were observed for packed cell volume, hemoglobin concentration, aspartate transaminase activity, and cholesterol, triglyceride, calcium, and phosphorus concentrations. Marked seasonal variation was observed in most parameters in conjunction with reproductive cycle, hibernation, or seasonal rainfall. Year-to-year differences and long-term alterations primarily reflected winter rainfall amounts. Site differences were minimal, and largely reflected geographic differences in precipitation patterns, such that results from these studies can be applied to other tortoise populations in environments with known rainfall and forage availability patterns.

  1. Hematology and plasma chemistry reference intervals for mature laboratory pine voles (Microtus pinetorum) as determined by using the nonparametric rank percentile method.

    PubMed

    Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A

    2008-07-01

    Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.

  2. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  3. WHO Melting-Point Reference Substances

    PubMed Central

    Bervenmark, H.; Diding, N. Å.; Öhrner, B.

    1963-01-01

    Batches of 13 highly purified chemicals, intended for use as reference substances in the calibration of apparatus for melting-point determinations, have been subjected to a collaborative assay by 15 laboratories in 13 countries. All the laboratories performed melting-point determinations by the capillary methods described in the proposed text for the second edition of the Pharmacopoea Internationalis and some, in addition, carried out determinations by the microscope hot stage (Kofler) method, using both the “going-through” and the “equilibrium” technique. Statistical analysis of the data obtained by the capillary method showed that the within-laboratory variation was small and that the between-laboratory variation, though constituting the greatest part of the whole variance, was not such as to warrant the exclusion of any laboratory from the evaluation of the results. The average values of the melting-points obtained by the laboratories can therefore be used as constants for the substances in question, which have accordingly been established as WHO Melting-Point Reference Substances and included in the WHO collection of authentic chemical substances. As to the microscope hot stage method, analysis of the results indicated that the values obtained by the “going-through” technique did not differ significantly from those obtained by the capillary method, but the values obtained by the “equilibrium” technique were mostly significantly lower. PMID:20604137

  4. Diagnostic utility of coeliac disease: a descriptive study in a tertiary care hospital, oman.

    PubMed

    Al Saidi, Safana Salim; Al Harthi, Salim Omar; Mula-Abed, Waad-Allah Sharef

    2013-07-01

    The prevalence of coeliac disease in Oman is unknown. We aim to estimate the prevalence of coeliac disease in at-risk subjects, describe the clinical characteristics and laboratory findings associated with coeliac disease and the validity of serological testing for coeliac disease at the Royal Hospital, Oman over a period of three years. This is a retrospective case finding study. The medical and laboratory records were reviewed for patients for whom serum antiendomysium IgA antibodies were requested at the Royal Hospital during a 3-year period (1(st) Jan 2006-31(st) Dec 2008). The data were extracted in order to assess the following: a) Prevalence rate of coeliac disease among at-risk subjects; b) Clinical characteristics in patients with coeliac disease and clinical manifestations for which the requesting clinicians considered coeliac disease as a possible diagnosis, including their specialties; c) Laboratory tests results in patients with coeliac disease; and d) Validity of antiendomysium antibodies testing in comparison with histopathology of jejunal biopsies for diagnosing coeliac disease. The study included 431 patients (250 females, 181 males) who were suspected of having (or screened for) coeliac disease. The median of age was 15 years (range: 9 months-74 years) with mean ± SD 18.95 ± 14.1 years. Of these, 15 (3.5%) patients (10 females, 5 males) with a median age of 19 years and mean 21.4 ± 13.0 years (range: 2.5-38 years), had positive antiendomysium antibodies results with median (range) of 160 (40-320) IU/L and mean± SD 204.5 ± 160 IU/L. Of these 15 patients, 13 had positive jejunal histopathological changes indicative of coeliac disease; the remaining 2 patients had no biopsy examination. Of the 44 patients with negative antiendomysium antibodies <10 IU/L who had jejunal biopsy, 41 were negative and 3 had histopathological changes suggestive of mild coeliac disease. All the 3 patients had serum total IgA levels within the reference range. The calculated validity indicators for antiendomysium antibodies were: sensitivity 81.3%, specificity 100%, positive predictive value 100%, negative predictive value 93.2% and efficiency 94.7%. The most common mode of presentation in patients with coeliac disease was gastrointestinal features, type 1 diabetes mellitus, anemia, short stature and hypothyroidism. The seropositivity in tye 1 diabetics was 4.9%. Investigations for coeliac disease were most frequently made by endocrinologists (pediatric and adult) who accounted for 53.8% followed by gastroenterologists (pediatric and adult) with 40.6% with less consideration by the other clinicians (5.6%). The availability of highly specific and sensitive serological test and increased awareness for coeliac disease among some medical specialties has increased the number of diagnosed cases of coeliac disease. The requesting for serological test is being made mainly by endocrinologists and gastroenterologists.

  5. Interior. Balance room for chemistry laboratory. Storage room for glassware ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior. Balance room for chemistry laboratory. Storage room for glassware and reference room with frequently used chemistry and chemical engineering texts. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ

  6. The Effect of Motion Analysis Activities in a Video-Based Laboratory in Students' Understanding of Position, Velocity and Frames of Reference

    ERIC Educational Resources Information Center

    Koleza, Eugenia; Pappas, John

    2008-01-01

    In this article, we present the results of a qualitative research project on the effect of motion analysis activities in a Video-Based Laboratory (VBL) on students' understanding of position, velocity and frames of reference. The participants in our research were 48 pre-service teachers enrolled in Education Departments with no previous strong…

  7. Reference intervals: current status, recent developments and future considerations.

    PubMed

    Ozarda, Yesim

    2016-01-01

    Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term 'RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. 
The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs.

  8. Reference intervals: current status, recent developments and future considerations

    PubMed Central

    Ozarda, Yesim

    2016-01-01

    Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term ‘RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area.
The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs. PMID:26981015

  9. Rapid, comprehensive, and affordable mycobacterial diagnosis with whole-genome sequencing: a prospective study

    PubMed Central

    Pankhurst, Louise J; del Ojo Elias, Carlos; Votintseva, Antonina A; Walker, Timothy M; Cole, Kevin; Davies, Jim; Fermont, Jilles M; Gascoyne-Binzi, Deborah M; Kohl, Thomas A; Kong, Clare; Lemaitre, Nadine; Niemann, Stefan; Paul, John; Rogers, Thomas R; Roycroft, Emma; Smith, E Grace; Supply, Philip; Tang, Patrick; Wilcox, Mark H; Wordsworth, Sarah; Wyllie, David; Xu, Li; Crook, Derrick W

    2016-01-01

    Summary Background Slow and cumbersome laboratory diagnostics for Mycobacterium tuberculosis complex (MTBC) risk delayed treatment and poor patient outcomes. Whole-genome sequencing (WGS) could potentially provide a rapid and comprehensive diagnostic solution. In this prospective study, we compare real-time WGS with routine MTBC diagnostic workflows. Methods We compared sequencing mycobacteria from all newly positive liquid cultures with routine laboratory diagnostic workflows across eight laboratories in Europe and North America for diagnostic accuracy, processing times, and cost between Sept 6, 2013, and April 14, 2014. We sequenced specimens once using local Illumina MiSeq platforms and processed data centrally using a semi-automated bioinformatics pipeline. We identified species or complex using gene presence or absence, predicted drug susceptibilities from resistance-conferring mutations identified from reference-mapped MTBC genomes, and calculated genetic distance to previously sequenced UK MTBC isolates to detect outbreaks. WGS data processing and analysis was done by staff masked to routine reference laboratory and clinical results. We also did a microcosting analysis to assess the financial viability of WGS-based diagnostics. Findings Compared with routine results, WGS predicted species with 93% (95% CI 90–96; 322 of 345 specimens; 356 mycobacteria specimens submitted) accuracy and drug susceptibility also with 93% (91–95; 628 of 672 specimens; 168 MTBC specimens identified) accuracy, with one sequencing attempt. WGS linked 15 (16% [95% CI 10–26]) of 91 UK patients to an outbreak. WGS diagnosed a case of multidrug-resistant tuberculosis before routine diagnosis was completed and discovered a new multidrug-resistant tuberculosis cluster. Full WGS diagnostics could be generated in a median of 9 days (IQR 6–10), a median of 21 days (IQR 14–32) faster than final reference laboratory reports were produced (median of 31 days [IQR 21–44]), at a cost of £481 per culture-positive specimen, whereas routine diagnosis costs £518, equating to a WGS-based diagnosis cost that is 7% cheaper annually than are present diagnostic workflows. Interpretation We have shown that WGS has a scalable, rapid turnaround, and is a financially feasible method for full MTBC diagnostics. Continued improvements to mycobacterial processing, bioinformatics, and analysis will improve the accuracy, speed, and scope of WGS-based diagnosis. Funding National Institute for Health Research, Department of Health, Wellcome Trust, British Colombia Centre for Disease Control Foundation for Population and Public Health, Department of Clinical Microbiology, Trinity College Dublin. PMID:26669893

  10. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    PubMed

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  11. [Congenital ChagaśDisease: epidemiology, laboratorial diagnosis, prognosis and treatment].

    PubMed

    Reiche, E M; Inouye, M M; Bonametti, A M; Jankevicius, J V

    1996-01-01

    The authors review studies about epidemiology, clinical aspects and methods used in laboratorial diagnosis of congenital Chagas'disease, emphasizing the limitations in their specificity and sensibility, and suggest alternative methods to improve the accuracy and the quality of the laboratorial diagnosis of congenital Chagaśdisease, essential to an efficient treatment.

  12. Assessment of geraniol-incorporated polymers to control Aedes albopictus (Diptera: culicidae)

    PubMed Central

    Chuaycharoensuk, T.; Manguin, S.; Duvallet, G.; Chareonviriyaphap, T.

    2012-01-01

    Effective control of mosquito borne diseases has proven extremely difficult with both vector and pathogen remaining entrenched and expanding in many disease endemic areas. When lacking an effective vaccine, vector control methods targeting both larval habitats and adult mosquito populations remain the primary strategy for reducing risk. Aedes albopictus from Thailand was used as a reference baseline for evaluation of natural insecticides incorporated in polymer disks and pellets and tested both in laboratory and field conditions. In laboratory and field tests, the highest larval mortality was obtained with disks or pellets containing IKHC (Insect Killer Highly Concentrate) from Fulltec AG Company. This product is reputed to contain geraniol as an active ingredient. With pellets, high mortality of Ae. albopictus larvae (92%) was observed in presence of 1 g of pellets per 500 ml of water at day 1st, and the mortality was 100% at day 1st for larvae in presence of 5 or 10 g of pellets. Fulltec AG Company has not accepted to give us the exact composition of their IKHC product. Therefore, we cannot recommend it, but the principle of using monoterpenes like geraniol, incorporated into polymer disks or pellets as natural larvicide needs more attention as it could be considered as a powerful alternative in mosquito vector control. PMID:22910616

  13. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN)

    PubMed Central

    2010-01-01

    Background The Worldwide Antimalarial Resistance Network (WWARN) is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC) programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM) in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor quality reference standards. By providing anti-malarial drug standards from a central point, it is possible to lower the cost of these standards. PMID:21184684

  14. Comparison of premier CAMPY enzyme immunoassay (EIA), ProSpecT Campylobacter EIA, and ImmunoCard STAT! CAMPY tests with culture for laboratory diagnosis of Campylobacter enteric infections.

    PubMed

    Granato, Paul A; Chen, Li; Holiday, Iris; Rawling, Russell A; Novak-Weekley, Susan M; Quinlan, Tammy; Musser, Kimberlee A

    2010-11-01

    Campylobacter enteritis is a food-borne or waterborne illness caused almost exclusively by Campylobacter jejuni and, to a lesser extent, by Campylobacter coli. These organisms produce indistinguishable clinical diseases and together represent the second most common cause of bacterial diarrhea in the United States and the leading cause of enteric infection throughout the world. The conventional approach to the laboratory diagnosis of Campylobacter enteritis is based on the recovery of the organism from a stool specimen, which requires the use of a specialized medium incubated at 42°C for several days in an artificially created microaerophilic environment. Recently, several commercially available enzyme immunoassays (EIAs) have been developed for the direct detection of C. jejuni and C. coli in stool specimens. This study compared conventional culture with three EIA methods, the Premier CAMPY EIA (Meridian Bioscience, Cincinnati, OH), the ProSpecT Campylobacter EIA (Remel, Lenexa, KS), and the ImmunoCard STAT! CAMPY test (Meridian Bioscience, Cincinnati, OH), for the detection of C. jejuni and C. coli in 485 patient stool samples. Discordant results were arbitrated by using an in-house, real-time PCR assay that was developed and validated by a public health reference laboratory. Following analyses of the discrepant specimens by PCR, the sensitivity and specificity of both the Premier CAMPY and ProSpecT Campylobacter EIAs were 99.3% and 98%, respectively, while the ImmunoCard STAT! CAMPY test had a sensitivity of 98.5% and a specificity of 98.2%. By use of the PCR test as the reference standard, culture detected 127 of 135 Campylobacter-positive stool specimens, yielding a sensitivity of 94.1%. These results showed that the three EIAs evaluated in this study provide a rapid and reliable alternative for the laboratory diagnosis of enteric infections with C. jejuni and C. coli and that conventional culture may no longer be recognized as the "gold standard" for diagnosis.

  15. Use of cerebrospinal fluid and serum samples impregnated on FTATM Elute filter paper for the diagnosis of infections caused by Neisseria meningitidis, Streptococcus pneumoniae and Haemophilus influenzae.

    PubMed

    Fukasawa, Lucila Okuyama; Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares

    2017-01-01

    The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo's national surveillance for routine diagnosis were selected for this study. The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory's standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer's instructions. The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory's standard methodology, results showed high concordance, with Kappa index ranges of 0.9877-1.00 for CSF, and 0.8004-1.00 for serum samples. The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost.

  16. Shingles Transmission

    MedlinePlus

    ... Clinical Overview Diagnosis & Testing Prevention in Health Care Settings Laboratory Testing Collecting VZV Specimens CDC National VZV Laboratory Surveillance Resources & References Multimedia Related Links Medline Plus NIH SeniorHealth ...

  17. Measurement uncertainty: Friend or foe?

    PubMed

    Infusino, Ilenia; Panteghini, Mauro

    2018-02-02

    The definition and enforcement of a reference measurement system, based on the implementation of metrological traceability of patients' results to higher order reference methods and materials, together with a clinically acceptable level of measurement uncertainty, are fundamental requirements to produce accurate and equivalent laboratory results. The uncertainty associated with each step of the traceability chain should be governed to obtain a final combined uncertainty on clinical samples fulfilling the requested performance specifications. It is important that end-users (i.e., clinical laboratory) may know and verify how in vitro diagnostics (IVD) manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. However, full information about traceability and combined uncertainty of calibrators is currently very difficult to obtain. Laboratory professionals should investigate the need to reduce the uncertainty of the higher order metrological references and/or to increase the precision of commercial measuring systems. Accordingly, the measurement uncertainty should not be considered a parameter to be calculated by clinical laboratories just to fulfil the accreditation standards, but it must become a key quality indicator to describe both the performance of an IVD measuring system and the laboratory itself. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Safety in the Chemical Laboratory: Learning How to Run Safer Undergraduate Laboratories.

    ERIC Educational Resources Information Center

    Mohrig, Jerry R.

    1983-01-01

    Discusses responsibilities for providing safe experiments and for teaching about safety. Provides lists of references on chemical safety and regulated/potential carcinogens. Also discusses general laboratory safety procedures including waste disposal and recycling of solvents. (JM)

  19. A short history, principles, and types of ELISA, and our laboratory experience with peptide/protein analyses using ELISA.

    PubMed

    Aydin, Suleyman

    2015-10-01

    Playing a critical role in the metabolic homeostasis of living systems, the circulating concentrations of peptides/proteins are influenced by a variety of patho-physiological events. These peptide/protein concentrations in biological fluids are measured using various methods, the most common of which is enzymatic immunoassay EIA/ELISA and which guide the clinicians in diagnosing and monitoring diseases that inflict biological systems. All the techniques where enzymes are employed to show antigen-antibody reactions are generally referred to as enzymatic immunoassay EIA/ELISA method. Since the basic principles of EIA and ELISA are the same. The main objective of this review is to present an overview of the historical journey that had led to the invention of EIA/ELISA, an indispensible method for medical and research laboratories, types of ELISA developed after its invention [direct (the first ELISA method invented), indirect, sandwich and competitive methods], problems encountered during peptide/protein analyses (pre-analytical, analytical and post-analytical), rules to be followed to prevent these problems, and our laboratory experience of more than 15 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Experimenting with Spirituality: Analyzing The God Gene in a Nonmajors Laboratory Course

    PubMed Central

    2008-01-01

    References linking genes to complex human traits, such as personality type or disease susceptibility, abound in the news media and popular culture. In his book The God Gene: How Faith is Hardwired into Our Genes, Dean Hamer argues that a variation in the VMAT2 gene plays a role in one's openness to spiritual experiences. In a nonmajors class, we read and discussed The God Gene and conducted on a small scale an extension of the study it describes. Students used polymerase chain reaction to replicate a portion of their VMAT2 genes, and they analyzed three polymorphic sites in the sequence of these products. Associations between particular VMAT2 alleles and scores on a personality test were assessed by t test. The course, of which this project was a major part, stimulated student learning; scores on a test covering basic genetic concepts, causation/correlation, and laboratory methodology improved after completion of the course. In a survey, students reported the laboratory project aided their learning, especially in the areas of statistics and the linking of genes to behaviors. They reported high levels of engagement with the project, citing in particular its personal nature as motivating their interest. PMID:18316816

  1. Pediatric Autoimmune Neuropsychiatric Disorder Associated with Streptococcal Infections (PANDAS): Experience at a Tertiary Referral Center

    PubMed Central

    Helm, Caitlin E.; Blackwood, R. Alexander

    2015-01-01

    Background Pediatric autoimmune neuropsychiatric disorder associated with streptococcal infections (PANDAS) is an autoimmune disorder presenting with obsessive compulsive disorder and/or tics. Like Sydenham’s chorea, its presumed pathogenesis consists of autoantibodies cross-reacting with neurons in response to a group A beta-hemolytic streptococcal infection (GASI). There are currently no diagnostic laboratory findings and management ranges from antibiotic prophylaxis to intravenous immunoglobulin to plasmapheresis. The diagnosis remains controversial, resulting in inconsistent referrals and significant patient anxiety. Methods A retrospective study was performed on all patients referred to the Pediatric Infectious Disease Division with a pre-referral diagnosis of PANDAS. Patients were analyzed by demographics, medical history, co-morbidities, symptoms, prior treatment, laboratory tests, management strategies, and treatment outcomes. Results From 2003 to 2013, there were 21 patients with a pre-referral diagnosis of PANDAS. Only five met the diagnostic criteria. No patient at referral had an objective scale to monitor symptoms. Eight referrals had a major psychiatric disorder, and none fulfilled diagnostic criteria (p<0.01). Discussion The majority of the patients referred with a pre-diagnosis of PANDAS do not fulfill diagnostic criteria nor do they have objective criteria for symptom monitoring. Major psychiatric disorders do not seem to be associated with PANDAS, and better physician education may prevent misdiagnoses. Multidisciplinary management is recommended. PMID:26196024

  2. CSF Aβ1-42 - an excellent but complicated Alzheimer's biomarker - a route to standardisation.

    PubMed

    Kuhlmann, Julia; Andreasson, Ulf; Pannee, Josef; Bjerke, Maria; Portelius, Erik; Leinenbach, Andreas; Bittner, Tobias; Korecka, Magdalena; Jenkins, Rand G; Vanderstichele, Hugo; Stoops, Erik; Lewczuk, Piotr; Shaw, Leslie M; Zegers, Ingrid; Schimmel, Heinz; Zetterberg, Henrik; Blennow, Kaj

    2017-04-01

    The 42 amino acid form of amyloid β (Aβ 1 - 42 ) in cerebrospinal fluid (CSF) has been widely accepted as a central biomarker for Alzheimer's disease. Several immunoassays for CSF Aβ 1-42 are commercially available, but can suffer from between laboratory and batch-to-batch variability as well as lack of standardisation across assays. As a consequence, no general cut-off values have been established for a specific context of use (e.g., clinical diagnostics) and selection of individuals for enrolment in clinical trials (patient stratification) remains challenging. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has initiated a working group for CSF proteins (WG-CSF) to facilitate standardisation of CSF Aβ 1-42 measurement results. The efforts of the IFCC WG-CSF include the development of certified reference materials (CRMs) and reference measurement procedures (RMPs) for key biomarkers. Two candidate RMPs for quantification of Aβ 1-42 in CSF based on liquid chromatography tandem mass spectrometry have been developed and tested in two ring trials. Furthermore, two commutability studies including native CSF pools, artificial CSF and spiked materials have been completed. On the basis of these studies, human CSF pools containing only endogenous Aβ 1-42 at three concentrations were selected as the format for future CRMs that are now being processed. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    PubMed

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  4. hemaClass.org: Online One-By-One Microarray Normalization and Classification of Hematological Cancers for Precision Medicine.

    PubMed

    Falgreen, Steffen; Ellern Bilgrau, Anders; Brøndum, Rasmus Froberg; Hjort Jakobsen, Lasse; Have, Jonas; Lindblad Nielsen, Kasper; El-Galaly, Tarec Christoffer; Bødker, Julie Støve; Schmitz, Alexander; H Young, Ken; Johnsen, Hans Erik; Dybkær, Karen; Bøgsted, Martin

    2016-01-01

    Dozens of omics based cancer classification systems have been introduced with prognostic, diagnostic, and predictive capabilities. However, they often employ complex algorithms and are only applicable on whole cohorts of patients, making them difficult to apply in a personalized clinical setting. This prompted us to create hemaClass.org, an online web application providing an easy interface to one-by-one RMA normalization of microarrays and subsequent risk classifications of diffuse large B-cell lymphoma (DLBCL) into cell-of-origin and chemotherapeutic sensitivity classes. Classification results for one-by-one array pre-processing with and without a laboratory specific RMA reference dataset were compared to cohort based classifiers in 4 publicly available datasets. Classifications showed high agreement between one-by-one and whole cohort pre-processsed data when a laboratory specific reference set was supplied. The website is essentially the R-package hemaClass accompanied by a Shiny web application. The well-documented package can be used to run the website locally or to use the developed methods programmatically. The website and R-package is relevant for biological and clinical lymphoma researchers using affymetrix U-133 Plus 2 arrays, as it provides reliable and swift methods for calculation of disease subclasses. The proposed one-by-one pre-processing method is relevant for all researchers using microarrays.

  5. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis

    PubMed Central

    2014-01-01

    Background The increasing prevalence of diabetes in Ontario means that there will be growing demand for hemoglobin A1c (HbA1c) testing to monitor glycemic control for the management of this chronic disease. Testing HbA1c where patients receive their diabetes care may improve system efficiency if the results from point-of-care HbA1c testing are comparable to those from laboratory HbA1c measurements. Objectives To review the correlation between point-of-care HbA1c testing and laboratory HbA1c measurement in patients with diabetes in clinical settings. Data Sources The literature search included studies published between January 2003 and June 2013. Search terms included glycohemoglobin, hemoglobin A1c, point of care, and diabetes. Review Methods Studies were included if participants had diabetes; if they compared point-of-care HbA1c devices (licensed by Health Canada and available in Canada) with laboratory HbA1c measurement (reference method); if they performed point-of-care HbA1c testing using capillary blood samples (finger pricks) and laboratory HbA1c measurement using venous blood samples within 7 days; and if they reported a correlation coefficient between point-of-care HbA1c and laboratory HbA1c results. Results Three point-of-care HbA1c devices were reviewed in this analysis: Bayer's A1cNow+, Bio-Rad's In2it, and Siemens’ DCA Vantage. Five observational studies met the inclusion criteria. The pooled results showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement (correlation coefficient, 0.967; 95% confidence interval, 0.960–0.973). Limitations Outcomes were limited to the correlation coefficient, as this was a commonly reported measure of analytical performance in the literature. Results should be interpreted with caution due to risk of bias related to selection of participants, reference standards, and the multiple steps involved in POC HbA1c testing. Conclusions Moderate quality evidence showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement. Five observational studies compared 3 point-of-care HbA1c devices with laboratory HbA1c assays, and all reported strong correlation between the 2 tests. PMID:26316922

  6. Frequency of Celiac Disease in Patients With Increased Intestinal Gas (Flatulence).

    PubMed

    Masoodi, Mohsen; Mokhtare, Marjan; Agah, Shahram; Sina, Mohammad; Soltani-Kermanshahi, Mojtaba

    2015-10-26

    Excessive flatulence which impairs social performance in patients is one of the common reasons for referrals to gastroenterology clinics. Celiac Disease is a rare but important cause of increased intestinal gas (bloating) and if not diagnosed, patients face complications such as malabsorption, anemia, osteoporosis and even intestinal lymphoma. This study aimed to determine the frequency of Celiac Disease in patients with excessive flatulence.One hundred and fifty patients with a chief complaint of experiencing flatulence more than 15 times a day and lasting for three months were referred to the gastroenterology clinic of Rasoul-e-Akram Teaching Hospital. Serological tests for Celiac Disease, Anti TTG Ab (IgA-IgG) were requested and the patients with positive tests underwent upper GI endoscopy. Biopsies of the second part of the duodenum were then sent to the laboratory.From one hundred and thirty patients who completed the study, 92 (70.7%) were female. Mean age of the patients was 32 ± 13 years. Anti TTG Ab was found in 5 patients (3.85%). Only 2 patients (1.5%) had a documented positive pathology for Celiac Disease.According to the results of this study and other studies, we conclude that Celiac Disease is an uncommon etiology for excessive flatulence but it is of importance to investigate it in excessive flatulence patients.

  7. Frequency of Celiac Disease in Patients with Increased Intestinal Gas (Flatulence)

    PubMed Central

    Masoodi, Mohsen; Mokhtare, Marjan; Agah, Shahram; Sina, Mohammad; Soltani-Kermanshahi, Mojtaba

    2016-01-01

    Excessive flatulence which impairs social performance in patients is one of the common reasons for referrals to gastroenterology clinics. Celiac Disease is a rare but important cause of increased intestinal gas (bloating) and if not diagnosed, patients face complications such as malabsorption, anemia, osteoporosis and even intestinal lymphoma. This study aimed to determine the frequency of Celiac Disease in patients with excessive flatulence. One hundred and fifty patients with a chief complaint of experiencing flatulence more than 15 times a day and lasting for three months were referred to the gastroenterology clinic of Rasoul-e-Akram Teaching Hospital. Serological tests for Celiac Disease, Anti TTG Ab (IgA-IgG) were requested and the patients with positive tests underwent upper GI endoscopy. Biopsies of the second part of the duodenum were then sent to the laboratory. From one hundred and thirty patients who completed the study, 92 (70.7%) were female. Mean age of the patients was 32 ± 13 years. Anti TTG Ab was found in 5 patients (3.85%). Only 2 patients (1.5%) had a documented positive pathology for Celiac Disease. According to the results of this study and other studies, we conclude that Celiac Disease is an uncommon etiology for excessive flatulence but it is of importance to investigate it in excessive flatulence patients. PMID:26755470

  8. Development and inter-laboratory validation study of an improved new real-time PCR assay with internal control for detection and laboratory diagnosis of African swine fever virus.

    PubMed

    Tignon, Marylène; Gallardo, Carmina; Iscaro, Carmen; Hutet, Evelyne; Van der Stede, Yves; Kolbasov, Denis; De Mia, Gian Mario; Le Potier, Marie-Frédérique; Bishop, Richard P; Arias, Marisa; Koenen, Frank

    2011-12-01

    A real-time polymerase chain reaction (PCR) assay for the rapid detection of African swine fever virus (ASFV), multiplexed for simultaneous detection of swine beta-actin as an endogenous control, has been developed and validated by four National Reference Laboratories of the European Union for African swine fever (ASF) including the European Union Reference Laboratory. Primers and a TaqMan(®) probe specific for ASFV were selected from conserved regions of the p72 gene. The limit of detection of the new real-time PCR assay is 5.7-57 copies of the ASFV genome. High accuracy, reproducibility and robustness of the PCR assay (CV ranging from 0.7 to 5.4%) were demonstrated both within and between laboratories using different real-time PCR equipments. The specificity of virus detection was validated using a panel of 44 isolates collected over many years in various geographical locations in Europe, Africa and America, including recent isolates from the Caucasus region, Sardinia, East and West Africa. Compared to the OIE-prescribed conventional and real-time PCR assays, the sensitivity of the new assay with internal control was improved, as demonstrated by testing 281 field samples collected in recent outbreaks and surveillance areas in Europe and Africa (170 samples) together with samples obtained through experimental infections (111 samples). This is particularly evident in the early days following experimental infection and during the course of the disease in pigs sub-clinically infected with strains of low virulence (from 35 up to 70dpi). The specificity of the assay was also confirmed on 150 samples from uninfected pigs and wild boar from ASF-free areas. Measured on the total of 431 tested samples, the positive deviation of the new assay reaches 21% or 26% compared to PCR and real-time PCR methods recommended by OIE. This improved and rigorously validated real-time PCR assay with internal control will provide a rapid, sensitive and reliable molecular tool for ASFV detection in pigs in newly infected areas, control in endemic areas and surveillance in ASF-free areas. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Molecular detection of Borrelia burgdorferi sensu lato – An analytical comparison of real-time PCR protocols from five different Scandinavian laboratories

    PubMed Central

    Faller, Maximilian; Wilhelmsson, Peter; Kjelland, Vivian; Andreassen, Åshild; Dargis, Rimtas; Quarsten, Hanne; Dessau, Ram; Fingerle, Volker; Margos, Gabriele; Noraas, Sølvi; Ornstein, Katharina; Petersson, Ann-Cathrine; Matussek, Andreas; Lindgren, Per-Eric; Henningsson, Anna J.

    2017-01-01

    Introduction Lyme borreliosis (LB) is the most common tick transmitted disease in Europe. The diagnosis of LB today is based on the patient´s medical history, clinical presentation and laboratory findings. The laboratory diagnostics are mainly based on antibody detection, but in certain conditions molecular detection by polymerase chain reaction (PCR) may serve as a complement. Aim The purpose of this study was to evaluate the analytical sensitivity, analytical specificity and concordance of eight different real-time PCR methods at five laboratories in Sweden, Norway and Denmark. Method Each participating laboratory was asked to analyse three different sets of samples (reference panels; all blinded) i) cDNA extracted and transcribed from water spiked with cultured Borrelia strains, ii) cerebrospinal fluid spiked with cultured Borrelia strains, and iii) DNA dilution series extracted from cultured Borrelia and relapsing fever strains. The results and the method descriptions of each laboratory were systematically evaluated. Results and conclusions The analytical sensitivities and the concordance between the eight protocols were in general high. The concordance was especially high between the protocols using 16S rRNA as the target gene, however, this concordance was mainly related to cDNA as the type of template. When comparing cDNA and DNA as the type of template the analytical sensitivity was in general higher for the protocols using DNA as template regardless of the use of target gene. The analytical specificity for all eight protocols was high. However, some protocols were not able to detect Borrelia spielmanii, Borrelia lusitaniae or Borrelia japonica. PMID:28937997

  10. An online paradigm for exploring the self-reference effect

    PubMed Central

    Bentley, Sarah V.; Greenaway, Katharine H.; Haslam, S. Alexander

    2017-01-01

    People reliably encode information more effectively when it is related in some way to the self—a phenomenon known as the self-reference effect. This effect has been recognized in psychological research for almost 40 years, and its scope as a tool for investigating the self-concept is still expanding. The self-reference effect has been used within a broad range of psychological research, from cultural to neuroscientific, cognitive to clinical. Traditionally, the self-reference effect has been investigated in a laboratory context, which limits its applicability in non-laboratory samples. This paper introduces an online version of the self-referential encoding paradigm that yields reliable effects in an easy-to-administer procedure. Across four studies (total N = 658), this new online tool reliably replicated the traditional self-reference effect: in all studies self-referentially encoded words were recalled significantly more than semantically encoded words (d = 0.63). Moreover, the effect sizes obtained with this online tool are similar to those obtained in laboratory samples, and are robust to experimental variations in encoding time (Studies 1 and 2) and recall procedure (Studies 3 and 4), and persist independent of primacy and recency effects (all studies). PMID:28472160

  11. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  12. Comprehensive viral enrichment enables sensitive respiratory virus genomic identification and analysis by next generation sequencing.

    PubMed

    O'Flaherty, Brigid M; Li, Yan; Tao, Ying; Paden, Clinton R; Queen, Krista; Zhang, Jing; Dinwiddie, Darrell L; Gross, Stephen M; Schroth, Gary P; Tong, Suxiang

    2018-06-01

    Next generation sequencing (NGS) technologies have revolutionized the genomics field and are becoming more commonplace for identification of human infectious diseases. However, due to the low abundance of viral nucleic acids (NAs) in relation to host, viral identification using direct NGS technologies often lacks sufficient sensitivity. Here, we describe an approach based on two complementary enrichment strategies that significantly improves the sensitivity of NGS-based virus identification. To start, we developed two sets of DNA probes to enrich virus NAs associated with respiratory diseases. The first set of probes spans the genomes, allowing for identification of known viruses and full genome sequencing, while the second set targets regions conserved among viral families or genera, providing the ability to detect both known and potentially novel members of those virus groups. Efficiency of enrichment was assessed by NGS testing reference virus and clinical samples with known infection. We show significant improvement in viral identification using enriched NGS compared to unenriched NGS. Without enrichment, we observed an average of 0.3% targeted viral reads per sample. However, after enrichment, 50%-99% of the reads per sample were the targeted viral reads for both the reference isolates and clinical specimens using both probe sets. Importantly, dramatic improvements on genome coverage were also observed following virus-specific probe enrichment. The methods described here provide improved sensitivity for virus identification by NGS, allowing for a more comprehensive analysis of disease etiology. © 2018 O'Flaherty et al.; Published by Cold Spring Harbor Laboratory Press.

  13. Comprehensive haematological indices reference intervals for a healthy Omani population: First comprehensive study in Gulf Cooperation Council (GCC) and Middle Eastern countries based on age, gender and ABO blood group comparison.

    PubMed

    Al-Mawali, Adhra; Pinto, Avinash Daniel; Al-Busaidi, Raiya; Al-Lawati, Rabab H; Morsi, Magdi

    2018-01-01

    Reference intervals for venous blood parameters differs with age, gender, geographic region, and ethnic groups. Hence local laboratory reference intervals are important to improve the diagnostic accuracy of health assessments and diseases. However, there have been no comprehensive published reference intervals established in Oman, the Gulf Cooperation Council or Middle Eastern countries. Hence, the aim of this study was to establish reference intervals for full blood count in healthy Omani adults. Venous blood specimens were collected from 2202 healthy individuals aged 18 to 69 years from January 2012 to April 2017, and analysed by Sysmex XS-1000i and Cell-Dyn Sapphire automated haematology analysers. Results were statistically analysed and compared by gender, age, and ABO blood group. The lower and upper reference limits of the haematology reference intervals were established at the 2.5th and 97.5th percentiles respectively. Reference intervals were calculated for 17 haematology parameters which included red blood cell, white blood cell, and platelet parameters. Red blood cell (RBC), haemoglobin (HGB), haematocrit (HCT), platelet and platelet haematocrit counts of the healthy donors were significantly different between males and females at all ages (p < 0.05), with males having higher mean values of RBC, HGB and HCT than females. Other complete blood count parameters showed no significant differences between genders, age groups, instruments, or blood groups. Our study showed a lower haemoglobin limit for the normal reference interval in males and females than the currently used in Oman. Data from this study established specific reference intervals which could be considered for general use in Oman. The differences in haematology reference intervals highlights the necessity to establish reference intervals for venous blood parameters among the healthy population in each country or at least in each region.

  14. Comparison of methods available for identification of Mycobacterium chimaera.

    PubMed

    Lecorche, E; Haenn, S; Mougari, F; Kumanski, S; Veziris, N; Benmansour, H; Raskine, L; Moulin, L; Cambau, E

    2018-04-01

    Mycobacterium chimaera is a recently described nontuberculous mycobacterium belonging to the Mycobacterium avium complex (MAC). Because this species is implicated in a worldwide outbreak due to contaminated heater-cooler unit water tanks during open-heart surgery, it has become mandatory for clinical microbiology laboratories to be able to differentiate M. chimaera from the other MAC species, especially M. intracellulare. Such identification has so far been restricted to specialized laboratories because it required the analysis of several gene sequences. The aim of this study was to evaluate commercial methods for identifying M. chimaera with regard to the reference gene sequencing ITS, the internal transcribed spacer 16-23S. Forty-seven clinical and environmental isolates including 41 MAC were identified by (a) PCR sequencing of the ITS and hsp65 genes, (b) three molecular biology kits (INNO-LiPA Mycobacteria, GenoType Mycobacterium CM and GenoType NTM-DR) and (c) matrix-assisted desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) using Microflex LT. There was a high concordance for species determination between the reference ITS sequencing and the GenoType NTM-DR test (39/41, 95%), the INNO-LiPA Mycobacteria test (38/41, 93%) and the hsp65 sequencing (38/41, 93%). The GenoType Mycobacterium CM test did not distinguish M. chimaera from M. intracellulare. MALDI-TOF MS distinguished two M. chimaera-M. intracellulare groups separated from M. avium and from the other mycobacterial species on a score-oriented dendrogram, but it also failed to differentiate the two species. INNO-LiPA Mycobacteria and GenoType NTM-DR are efficient assays for M. chimaera identification in clinical microbiology laboratories. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  15. [Importance of electromiographic examination in diagnostification and monitoring of chronic inflammatory demyelinating polyneuropathy].

    PubMed

    Damjan, Igor; Cvijanović, Milan; Erak, Marko

    2010-01-01

    Polyneuropathies or peripheral neuropathies present a dysfunction or disease of larger number of peripheral nerves or their dysfunction. Considering their morbidity - mortality characteristics they present an important aspect in daily clinical practice. One particular polyneuropathy that deserves special review is chronic inflammatory demyelinating polyneuropathy, which, due to its clinical-laboratory presentation, does not include the group of "simple" neuropathies, thus requiring further examinations. Neurophysiological testing should be performed using the protocol for neuropathy examinations. Neurophysiological examination, during the electroneurographic examination, shows neurographic parameters referring to polyneuropatic demyelinating type of lesion, while the electromyographic finding records the presence of neuropathic lesions (denervation activity, great action potentials with a reduced sample). A 54-year-old patient was diagnosed to have a "complicated" demyelinating polyneuropathy according to the clinical-laboratory findings and electromyographic examination. Exclusion criteria, targeted diagnostic examinations, considering the mentioned peripheral neuropathies, pointed to acute inflammatory demyelinating polyneuropathy. However, the chronic inflammatory demyelinating polyneuropathy was finally differentiated during the clinical and electromyographic monitoring.

  16. Activities of the Korean Institute of Tuberculosis

    PubMed Central

    Ryoo, Sungweon; Kim, Hee Jin

    2014-01-01

    The Korean National Tuberculosis Association (KNTA) set up the Korean Institute of Tuberculosis (KIT) in 1970 to foster research and technical activities pertaining to tuberculosis (TB). The KNTA/KIT had successfully conducted a countrywide TB prevalence survey from 1965 to 1995 at 5-year intervals. The survey results (decline in TB rates) established Korea as a country that had successfully implemented national control programs for TB. The KIT developed the Korea Tuberculosis Surveillance System and the Laboratory Management Information System, both of which were transferred to the Korea Centers for Disease Control and Prevention after its establishment. The KIT functions as a central and supranational reference TB laboratory for microbiological and epidemiological research and provides training and education for health-care workers and medical practitioners. Recently, the KIT has expanded its activities to countries such as Ethiopia, Laos, and Timor-Leste to support TB control and prevention. The KIT will continue to support research activities and provide technical assistance in diagnosing the infection until it is completely eliminated in Korea. PMID:25861580

  17. Operation of pneumococcal polysaccharide radioimmunoassay reference laboratory: coordination of the serological aspects of otitis media field trials. Annual report 28 Jun 77--27 Jun 78

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schiffman, G.

    1978-04-03

    The contract supports a serologic reference laboratory for the performance of radioimmunoassay of antibodies to pneumococcal polysaccharides. Antibody assays have been performed for a number of investigators studying the response of humans to pneumococcal vaccines. In addition, a large quantity of labeled polysaccharides for use in the assay have been prepared and stored.

  18. 78 FR 44954 - Clinical Laboratory Improvement Advisory Committee (CLIAC)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Clinical... and Human Services; the Assistant Secretary for Health; the Director, Centers for Disease Control and... laboratory quality and laboratory [[Page 44955

  19. Harmonized Reference Ranges for Circulating Testosterone Levels in Men of Four Cohort Studies in the United States and Europe

    PubMed Central

    Travison, Thomas G.; Vesper, Hubert W.; Orwoll, Eric; Wu, Frederick; Kaufman, Jean Marc; Wang, Ying; Lapauw, Bruno; Fiers, Tom; Matsumoto, Alvin M.

    2017-01-01

    Background: Reference ranges for testosterone are essential for making a diagnosis of hypogonadism in men. Objective: To establish harmonized reference ranges for total testosterone in men that can be applied across laboratories by cross-calibrating assays to a reference method and standard. Population: The 9054 community-dwelling men in cohort studies in the United States and Europe: Framingham Heart Study; European Male Aging Study; Osteoporotic Fractures in Men Study; and Male Sibling Study of Osteoporosis. Methods: Testosterone concentrations in 100 participants in each of the four cohorts were measured using a reference method at Centers for Disease Control and Prevention (CDC). Generalized additive models and Bland-Altman analyses supported the use of normalizing equations for transformation between cohort-specific and CDC values. Normalizing equations, generated using Passing-Bablok regression, were used to generate harmonized values, which were used to derive standardized, age-specific reference ranges. Results: Harmonization procedure reduced intercohort variation between testosterone measurements in men of similar ages. In healthy nonobese men, 19 to 39 years, harmonized 2.5th, 5th, 50th, 95th, and 97.5th percentile values were 264, 303, 531, 852, and 916 ng/dL, respectively. Age-specific harmonized testosterone concentrations in nonobese men were similar across cohorts and greater than in all men. Conclusion: Harmonized normal range in a healthy nonobese population of European and American men, 19 to 39 years, is 264 to 916 ng/dL. A substantial proportion of intercohort variation in testosterone levels is due to assay differences. These data demonstrate the feasibility of generating harmonized reference ranges for testosterone that can be applied to assays, which have been calibrated to a reference method and calibrator. PMID:28324103

  20. [Unnecessary routine laboratory tests in patients referred for surgical services].

    PubMed

    Mata-Miranda, María del Pilar; Cano-Matus, Norberto; Rodriguez-Murrieta, Margarita; Guarneros-Zapata, Idalia; Ortiz, Mario

    2016-01-01

    To question the usefulness of the lab analysis considered routine testing for the identification of abnormalities in the surgical care. To determine the percentage of unnecessary laboratory tests in the preoperative assessment as well as to estimate the unnecessary expenses. A descriptive, cross-sectional study of patients referred for surgical evaluation between January 1st and March 31st 2013. The database of laboratory testing and electronic files were reviewed. Reference criteria from surgical services were compared with the tests requested by the family doctor. In 65% of the patients (n=175) unnecessary examinations were requested, 25% (n=68) were not requested the tests that they required, and only 10% of the patients were requested laboratory tests in accordance with the reference criteria (n=27). The estimated cost in unnecessary examinations was $1,129,552 in a year. The results were similar to others related to this theme, however, they had not been revised from the perspective of the first level of attention regarding the importance of adherence to the reference criteria which could prevent major expenditures. It is a priority for leaders and operational consultants in medical units to establish strategies and lines of action that ensure compliance with institutional policies so as to contain spending on comprehensive services, and which in turn can improve the medical care. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  1. Reasons for Ineligibility in Phase 1 and 2A HIV Vaccine Clinical Trials at Kenya Aids Vaccine Initiative (KAVI), Kenya

    PubMed Central

    Omosa-Manyonyi, Gloria S.; Jaoko, Walter; Anzala, Omu; Ogutu, Hilda; Wakasiaka, Sabina; Malogo, Roselyn; Nyange, Jacqueline; Njuguna, Pamela; Ndinya-Achola, Jeckoniah; Bhatt, Kirana; Farah, Bashir; Oyaro, Micah; Schmidt, Claudia; Priddy, Frances; Fast, Patricia

    2011-01-01

    Background With the persistent challenges towards controlling the HIV epidemic, there is an ongoing need for research into HIV vaccines and drugs. Sub-Saharan African countries - worst affected by the HIV pandemic - have participated in the conduct of clinical trials for HIV vaccines. In Kenya, the Kenya AIDS Vaccine Initiative (KAVI) at the University of Nairobi has conducted HIV vaccine clinical trials since 2001. Methodology Participants were recruited after an extensive informed consent process followed by screening to determine eligibility. Screening included an assessment of risk behavior, medical history and physical examination, and if clinically healthy, laboratory testing. In the absence of locally derived laboratory reference ranges, the ranges used in these trials were derived from populations in the West. Principal findings Two hundred eighty-one participants were screened between 2003 and 2006 for two clinical trials. Of these, 167 (59.4%) met the inclusion/exclusion criteria. Overall, laboratory abnormalities based on the non-indigenous laboratory references used were the most frequent reasons (61.4%) for ineligibility. Medical abnormalities contributed 30.7% of the total reasons for ineligibility. Based on the laboratory reference intervals now developed from East and Southern Africa, those ineligible due to laboratory abnormalities would have been 46.3%. Of the eligible participants, 18.6% declined enrolment. Conclusions Participant recruitment for HIV vaccine clinical trials is a rigorous and time-consuming exercise. Over 61% of the screening exclusions in clinically healthy people were due to laboratory abnormalities. It is essential that laboratory reference ranges generated from local populations for laboratory values be used in the conduct of clinical trials to avoid unnecessary exclusion of willing participants and to avoid over-reporting of adverse events for enrolled participants. Trial registration Protocol IAVI VRC V001 [1]. ClinicalTrials.gov NCT00124007 Protocol IAVI 010 [2] (registration with ClincalTrials.gov is in progress) Protocols IAVI 002 and IAVI 004 are Phase 1 trials only mentioned in introductory paragraphs; details will not be reported. Registration was not required when they were conducted. PMID:21283743

  2. A digital microfluidic system for serological immunoassays in remote settings.

    PubMed

    Ng, Alphonsus H C; Fobel, Ryan; Fobel, Christian; Lamanna, Julian; Rackus, Darius G; Summers, Aimee; Dixon, Christopher; Dryden, Michael D M; Lam, Charis; Ho, Man; Mufti, Nooman S; Lee, Victor; Asri, Mohd Afiq Mohd; Sykes, Edward A; Chamberlain, M Dean; Joseph, Rachael; Ope, Maurice; Scobie, Heather M; Knipes, Alaine; Rota, Paul A; Marano, Nina; Chege, Paul M; Njuguna, Mary; Nzunza, Rosemary; Kisangau, Ngina; Kiogora, John; Karuingi, Michael; Burton, John Wagacha; Borus, Peter; Lam, Eugene; Wheeler, Aaron R

    2018-04-25

    Serosurveys are useful for assessing population susceptibility to vaccine-preventable disease outbreaks. Although at-risk populations in remote areas could benefit from this type of information, they face several logistical barriers to implementation, such as lack of access to centralized laboratories, cold storage, and transport of samples. We describe a potential solution: a compact and portable, field-deployable, point-of-care system relying on digital microfluidics that can rapidly test a small volume of capillary blood for disease-specific antibodies. This system uses inexpensive, inkjet-printed digital microfluidic cartridges together with an integrated instrument to perform enzyme-linked immunosorbent assays (ELISAs). We performed a field validation of the system's analytical performance at Kakuma refugee camp, a remote setting in northwestern Kenya, where we tested children aged 9 to 59 months and caregivers for measles and rubella immunoglobulin G (IgG). The IgG assays were determined to have sensitivities of 86% [95% confidence interval (CI), 79 to 91% (measles)] and 81% [95% CI, 73 to 88% (rubella)] and specificities of 80% [95% CI, 49 to 94% (measles)] and 91% [95% CI, 76 to 97% (rubella)] (measles, n = 140; rubella, n = 135) compared with reference tests (measles IgG and rubella IgG ELISAs from Siemens Enzygnost) conducted in a centralized laboratory. These results demonstrate a potential role for this point-of-care system in global serological surveillance, particularly in remote areas with limited access to centralized laboratories. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  3. ["Acute human glanders". Contribution for the scientific history of the Museum of pathological anatomy established in Trieste Hospital].

    PubMed

    Braulin, F

    2005-12-01

    The Museum of Pathological Anatomy of the Regina Elena City Hospital of Trieste houses various pathological preparations of infective and contagious diseases, dating back to the early 1900's (ileo-typhus, dysentery, tuberculosis, syphillis, pulmonary plague, etc.) together with their relative diagnostic certificates. These bear witness to the key role of the Hospital's Anatomical Institute (in operation operating since 1872) during the height of the Pasteurian age. In fact, the Institute houses several anatomical-pathological preparations from a fatal clinical case of "acute human glanders". These preparations were correlated by laboratory animal experiments using Strauss' method and emblematically recall the eziological determinism of the new bacteriological science. The preparations served in their day not only as indisputable diagnostic evidence, but can now be considered a promotional metaphor of the scientific mission the Triestine Anatomical Institutés Director, Dr. Enrico Ferrarri (a disciple of Richard Paltauf), endeavored to assign to the Triestine Pathological and Anatomical Institute by strenghthening it with new laboratory methodologies. The establishment of a new "predominant and determining vision" in the international diagnostics of infectious disease was also emerging from the Haspurg city's hospital medicine. Indeed, it was here that in 1907, the brief scientific debate focussing on the cadaver of a coachman who had been infected by a glanders-infected horse was apparently taking place only locally. Yet, it can now be seen as referring to what was happening on the international scale, in a setting that after a century of empiricism and morphologism, was characterized by the progressive penetration of laboratory medicine into clinical-anatomical medicine.

  4. European Society of Clinical Microbiology and Infectious Diseases: update of the diagnostic guidance document for Clostridium difficile infection.

    PubMed

    Crobach, M J T; Planche, T; Eckert, C; Barbut, F; Terveer, E M; Dekkers, O M; Wilcox, M H; Kuijper, E J

    2016-08-01

    In 2009 the first European Society of Clinical Microbiology and Infectious Diseases (ESCMID) guideline for diagnosing Clostridium difficile infection (CDI) was launched. Since then newer tests for diagnosing CDI have become available, especially nucleic acid amplification tests. The main objectives of this update of the guidance document are to summarize the currently available evidence concerning laboratory diagnosis of CDI and to formulate and revise recommendations to optimize CDI testing. This update is essential to improve the diagnosis of CDI and to improve uniformity in CDI diagnosis for surveillance purposes among Europe. An electronic search for literature concerning the laboratory diagnosis of CDI was performed. Studies evaluating a commercial laboratory test compared to a reference test were also included in a meta-analysis. The commercial tests that were evaluated included enzyme immunoassays (EIAs) detecting glutamate dehydrogenase, EIAs detecting toxins A and B and nucleic acid amplification tests. Recommendations were formulated by an executive committee, and the strength of recommendations and quality of evidence were graded using the Grades of Recommendation Assessment, Development and Evaluation (GRADE) system. No single commercial test can be used as a stand-alone test for diagnosing CDI as a result of inadequate positive predictive values at low CDI prevalence. Therefore, the use of a two-step algorithm is recommended. Samples without free toxin detected by toxins A and B EIA but with positive glutamate dehydrogenase EIA, nucleic acid amplification test or toxigenic culture results need clinical evaluation to discern CDI from asymptomatic carriage. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Digital microfluidic platform for multiplexing enzyme assays: implications for lysosomal storage disease screening in newborns.

    PubMed

    Sista, Ramakrishna S; Eckhardt, Allen E; Wang, Tong; Graham, Carrie; Rouse, Jeremy L; Norton, Scott M; Srinivasan, Vijay; Pollack, Michael G; Tolun, Adviye A; Bali, Deeksha; Millington, David S; Pamula, Vamsee K

    2011-10-01

    Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.

  6. Catalog of Federal metrology and calibration capabilities: 1980 edition

    NASA Astrophysics Data System (ADS)

    Leedy, K. O.

    1980-09-01

    Federal laboratories involved in metrology and calibration are listed. Included is the name of a person to contact at each laboratory telephone number and address. The capabilities of each laboratory are indicated in a tabular listing by agency. To provide geographical distribution, the laboratories are listed by States. In addition, the laboratories are shown on a map by coded number. Other references are described.

  7. Progress in increasing electronic reporting of laboratory results to public health agencies--United States, 2013.

    PubMed

    2013-09-27

    Electronic reporting of laboratory results to public health agencies can improve public health surveillance for reportable diseases and conditions by making reporting more timely and complete. Since 2010, CDC has provided funding to 57 state, local, and territorial health departments through the Epidemiology and Laboratory Capacity for Infectious Diseases cooperative agreement to assist with improving electronic laboratory reporting (ELR) from clinical and public health laboratories to public health agencies. As part of this agreement, CDC and state and large local health departments are collaborating to monitor ELR implementation in the United States by developing data from each jurisdiction regarding total reporting laboratories, laboratories sending ELR by disease category and message format, and the number of ELR laboratory reports compared with the total number of laboratory reports. At the end of July 2013, 54 of the 57 jurisdictions were receiving at least some laboratory reports through ELR, and approximately 62% of 20 million laboratory reports were being received electronically, compared with 54% in 2012. Continued progress will require collaboration between clinical laboratories, laboratory information management system (LIMS) vendors, and public health agencies.

  8. Hematology and Plasma Chemistry Reference Intervals for Mature Laboratory Pine Voles (Microtus pinetorum) as Determined by Using the Nonparametric Rank Percentile Method

    PubMed Central

    Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A

    2008-01-01

    Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449

  9. Identification of Leishmania by Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry Using a Free Web-Based Application and a Dedicated Mass-Spectral Library.

    PubMed

    Lachaud, Laurence; Fernández-Arévalo, Anna; Normand, Anne-Cécile; Lami, Patrick; Nabet, Cécile; Donnadieu, Jean Luc; Piarroux, Martine; Djenad, Farid; Cassagne, Carole; Ravel, Christophe; Tebar, Silvia; Llovet, Teresa; Blanchet, Denis; Demar, Magalie; Harrat, Zoubir; Aoun, Karim; Bastien, Patrick; Muñoz, Carmen; Gállego, Montserrat; Piarroux, Renaud

    2017-10-01

    Human leishmaniases are widespread diseases with different clinical forms caused by about 20 species within the Leishmania genus. Leishmania species identification is relevant for therapeutic management and prognosis, especially for cutaneous and mucocutaneous forms. Several methods are available to identify Leishmania species from culture, but they have not been standardized for the majority of the currently described species, with the exception of multilocus enzyme electrophoresis. Moreover, these techniques are expensive, time-consuming, and not available in all laboratories. Within the last decade, mass spectrometry (MS) has been adapted for the identification of microorganisms, including Leishmania However, no commercial reference mass-spectral database is available. In this study, a reference mass-spectral library (MSL) for Leishmania isolates, accessible through a free Web-based application (mass-spectral identification [MSI]), was constructed and tested. It includes mass-spectral data for 33 different Leishmania species, including species that infect humans, animals, and phlebotomine vectors. Four laboratories on two continents evaluated the performance of MSI using 268 samples, 231 of which were Leishmania strains. All Leishmania strains, but one, were correctly identified at least to the complex level. A risk of species misidentification within the Leishmania donovani , L. guyanensis , and L. braziliensis complexes was observed, as previously reported for other techniques. The tested application was reliable, with identification results being comparable to those obtained with reference methods but with a more favorable cost-efficiency ratio. This free online identification system relies on a scalable database and can be implemented directly in users' computers. Copyright © 2017 American Society for Microbiology.

  10. The Laboratory. Guides for the Improvement of Instruction in Higher Education, No. 9.

    ERIC Educational Resources Information Center

    Alexander, Lawrence T.; And Others

    This guide for the improvement of instruction in higher education is designed to aid the educator in planning and conducting laboratory instruction. The examples used refer primarily to science laboratories. Topics discussed include: deciding whether or not to use the laboratory method (with a discussion of discovery learning or the processes of…

  11. Pilot-Scale Laboratory Instruction for Chemical Engineering: The Specific Case of the Pilot-Unit Leading Group

    ERIC Educational Resources Information Center

    Billet, Anne-Marie; Camy, Severine; Coufort-Saudejaud, Carole

    2010-01-01

    This paper presents an original approach for Chemical Engineering laboratory teaching that is currently applied at INP-ENSIACET (France). This approach, referred to as "pilot-unit leading group" is based on a partial management of the laboratories by the students themselves who become temporarily in charge of one specific laboratory. In…

  12. Glucose Measurement: Time for a Gold Standard

    PubMed Central

    Hagvik, Joakim

    2007-01-01

    There is no internationally recognized reference method for the measurement of blood glucose. The Centers for Disease Control and Prevention (CDC) highlighted the need for standardization some years ago when a project was started. The project objectives were to (1) investigate whether there are significant differences in calibration levels among currently used glucose monitors for home use and (2) develop a reference method for glucose determination. A first study confirmed the assumption that currently used home-use monitors differ significantly and that standardization is necessary in order to minimize variability and to improve patient care. As a reference method, CDC recommended a method based on isotope dilution gas chromatography–mass spectrometry, an assay that has received support from clinical chemists worldwide. CDC initiated a preliminary study to establish the suitability of this method, but then the project came to a halt. It is hoped that CDC, with support from the industry, as well as academic and professional organizations such as the American Association for Clinical Chemistry and International Federation of Clinical Chemistry and Laboratory Medicine, will be able to finalize the project and develop the long-awaited and much needed “gold standard” for glucose measurement. PMID:19888402

  13. New Brunswick Laboratory: Progress report, October 1993 through September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The mission of the New Brunswick Laboratory of the US Department of Energy (DOE) is to serve as the National Certifying Authority for nuclear reference materials and to provide an independent Federal technical staff and laboratory resource performing nuclear material measurement, safeguards and non-proliferation functions in support of multiple program sponsors. During FY 94 New Brunswick Laboratory (NBL) completed development of a Strategic Plan which will aid in better defining performance oriented laboratory goals and objectives in each functional area consistent with the changing needs of the global nuclear community. This annual report describes accomplishments achieved in carrying out NBL`smore » assigned missions. Details of completed projects are reported in separate topical reports or as open-literature publications. Programs discussed here are: (1) safeguards assistance; (2) reference materials program; (3) measurement evaluation; (4) measurement services; and (5) measurement development.« less

  14. New Ca-Tims and La-Icp Analyses of GJ-1, Plesovice, and FC1 Reference Materials

    NASA Astrophysics Data System (ADS)

    Feldman, J. D.; Möller, A.; Walker, J. D.

    2014-12-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) U-Pb zircon geochronology relies on external reference standards to monitor and correct for different mass fractionation effects and instrument drift. Common zircon reference materials used within the community, including the KU Isotope Geochemistry Laboratory, are GJ-1 (207Pb/206Pb age: 608.53 +/- 0.37Ma; Jackson et al., 2004), Plesovice (337.13 +/- 0.37 Ma; Slama et al., 2008), and FC-1 (1099.0 +/-0.6 Ma; Paces and Miller, 1993). The age distribution of zircon reference material varies slightly from sample fraction to sample fraction, and the published results for GJ-1 are slightly discordant. As a result, using the published data for the distributed standard splits can lead to small systematic variations when comparing datasets from different labs, and more high precision data are needed to evaluate potential inhomogeneity of sample splits used in different laboratories. Here we characterize these reference materials with cathodoluminescence, LA-ICP-MS traverses across grains, and high precision CA-TIMS to better constrain the ages and assess zoning of these standards, and present the data for comparison with other laboratories. Reducing systematic error by dating our own reference material lends confidence to our analyses and allows for inter-laboratory age reproducibility of unknowns. Additionally, the reduction in propagated uncertainties (especially in GJ-1, for which both the red and yellow variety will be analyzed) will be used to improve long-term reproducibility, comparisons between samples of similar age, detrital populations and composite pluton zircons. Jackson, S.E., et al., 2004, Chemical Geology, v. 211, p. 47-69. Paces, J.B. & Miller, J.D., 1993, Journal of Geophysical Research, v. 80, p. 13997-14013. Slama, J., et al., 2008, Chemical Geology, v. 249. p. 1-35.

  15. Shigella isolates from the global enteric multicenter study inform vaccine development.

    PubMed

    Livio, Sofie; Strockbine, Nancy A; Panchalingam, Sandra; Tennant, Sharon M; Barry, Eileen M; Marohn, Mark E; Antonio, Martin; Hossain, Anowar; Mandomando, Inacio; Ochieng, John B; Oundo, Joseph O; Qureshi, Shahida; Ramamurthy, Thandavarayan; Tamboura, Boubou; Adegbola, Richard A; Hossain, Mohammed Jahangir; Saha, Debasish; Sen, Sunil; Faruque, Abu Syed Golam; Alonso, Pedro L; Breiman, Robert F; Zaidi, Anita K M; Sur, Dipika; Sow, Samba O; Berkeley, Lynette Y; O'Reilly, Ciara E; Mintz, Eric D; Biswas, Kousick; Cohen, Dani; Farag, Tamer H; Nasrin, Dilruba; Wu, Yukun; Blackwelder, William C; Kotloff, Karen L; Nataro, James P; Levine, Myron M

    2014-10-01

    Shigella, a major diarrheal disease pathogen worldwide, is the target of vaccine development. The Global Enteric Multicenter Study (GEMS) investigated burden and etiology of moderate-to-severe diarrheal disease in children aged <60 months and matched controls without diarrhea during 3 years at 4 sites in Africa and 3 in Asia. Shigella was 1 of the 4 most common pathogens across sites and age strata. GEMS Shigella serotypes are reviewed to guide vaccine development. Subjects' stool specimens/rectal swabs were transported to site laboratories in transport media and plated onto xylose lysine desoxycholate and MacConkey agar. Suspect Shigella colonies were identified by biochemical tests and agglutination with antisera. Shigella isolates were shipped to the GEMS Reference Laboratory (Baltimore, MD) for confirmation and serotyping of S. flexneri; one-third of isolates were sent to the Centers for Disease Control and Prevention for quality control. Shigella dysenteriae and S. boydii accounted for 5.0% and 5.4%, respectively, of 1130 Shigella case isolates; S. flexneri comprised 65.9% and S. sonnei 23.7%. Five serotypes/subserotypes comprised 89.4% of S. flexneri, including S. flexneri 2a, S. flexneri 6, S. flexneri 3a, S. flexneri 2b, and S. flexneri 1b. A broad-spectrum Shigella vaccine must protect against S. sonnei and 15 S. flexneri serotypes/subserotypes. A quadrivalent vaccine with O antigens from S. sonnei, S. flexneri 2a, S. flexneri 3a, and S. flexneri 6 can provide broad direct coverage against these most common serotypes and indirect coverage against all but 1 (rare) remaining subserotype through shared S. flexneri group antigens. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America.

  16. Dental Laboratory Technology.

    ERIC Educational Resources Information Center

    Department of the Air Force, Washington, DC.

    The Air Force dental laboratory technology manual is designed as a basic training text as well as a reference source for dental laboratory technicians, a specialty occupation concerned with the design, fabrication, and repair of dental prostheses. Numerous instructive diagrams and photographs are included throughout the manual. The comprehensive…

  17. Bottom-up or top-down: unit cost estimation of tuberculosis diagnostic tests in India.

    PubMed

    Rupert, S; Vassall, A; Raizada, N; Khaparde, S D; Boehme, C; Salhotra, V S; Sachdeva, K S; Nair, S A; Hoog, A H Van't

    2017-04-01

    Of 18 sites that participated in an implementation study of the Xpert® MTB/RIF assay in India, we selected five microscopy centres and two reference laboratories. To obtain unit costs of diagnostic tests for tuberculosis (TB) and drug-resistant TB. Laboratories were purposely selected to capture regional variations and different laboratory types. Both bottom-up and the top-down methods were used to estimate unit costs. At the microscopy centres, mean bottom-up unit costs were respectively US$0.83 (range US$0.60-US$1.10) and US$12.29 (US$11.61-US$12.89) for sputum smear microscopy and Xpert. At the reference laboratories, mean unit costs were US$1.69 for the decontamination procedure, US$9.83 for a solid culture, US$11.06 for a liquid culture, US$29.88 for a drug susceptibility test, and US$18.18 for a line-probe assay. Top-down mean unit cost estimates were higher for all tests, and for sputum smear microscopy and Xpert these increased to respectively US$1.51 and US$13.58. The difference between bottom-up and top-down estimates was greatest for tests performed at the reference laboratories. These unit costs for TB diagnostics can be used to estimate resource requirements and cost-effectiveness in India, taking into account geographical location, laboratory type and capacity utilisation.

  18. The Second National Ballistics Imaging Comparison (NBIC-2)

    PubMed Central

    Vorburger, TV; Yen, J; Song, JF; Thompson, RM; Renegar, TB; Zheng, A; Tong, M; Ols, M

    2014-01-01

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF’s National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. PMID:26601051

  19. The Second National Ballistics Imaging Comparison (NBIC-2).

    PubMed

    Vorburger, T V; Yen, J; Song, J F; Thompson, R M; Renegar, T B; Zheng, A; Tong, M; Ols, M

    2014-01-01

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

  20. [Cases of menstrual toxic shock syndrome in the Czech Republic in 1997-2011].

    PubMed

    Petrás, P; Machová, I; Rysková, L; Prásil, P

    2011-11-01

    To determine toxigenicity and other basic characteristics of 47 strains of Staphylococcus aureus referred to the National Reference Laboratory for Staphylococci (NRL) as suspected causative agents of menstrual toxic shock syndrome (MTSS). S. aureus strains were collected from 11 administrative regions of the Czech Republic in 1997-2011. The diagnosis was based on phenotypic (reverse latex agglutination test) and genotypic (polymerase chain reaction) methods. Forty-four S. aureus strains were producers of toxic shock syndrome toxin 1 (TSST-1), either alone or in combination with staphylococcal enterotoxin. Three strains only produced enterotoxin (B, C, and H). MTSS is a serious multisystem disease. In this study, MTSS often had a severe course requiring intensive care. All MTSS patients used vaginal tampons that had been identified in the literature as a risk factor for MTSS. The case of MTSS in a 36-year-old woman caused by an enterotoxin H positive strain of S. aureus is probably the first to be reported in the world.

  1. [Evaluation of a thyroid disease referral protocal in a health area of Madrid].

    PubMed

    López, A; Rollán, M T; Bedoya, M J; García, C

    The collaboration between healthcare levels is essential for our patients. The aim of this study is to determine the suitability of a referral protocol between the different healthcare levels. A collaboration study was carried out between general practitioners, endocrinologists, and the Department of Biochemistry. After creating the protocol together and implementing it, the suitability was evaluated. A total of 284 referral sheets were evaluated, 65% were adequately sent, and 51% were referred due to laboratory abnormalities, 42% for morphological alterations, and 7% for both reasons. Just under three-quarters (72%) were referred in the normal way (adequacy 90.6%). The clinical information in the referral sheet was considered adequate in 59%, and the request for ultrasound was adequate in 78%. A significant number (16%) of patients should have been returned to Primary Care. It is considered that creating protocols is part of our task. The compliance with the protocol can be improved in Primary Care and specialised care. Publicado por Elsevier España, S.L.U.

  2. Global standardization measurement of cerebral spinal fluid for Alzheimer's disease: an update from the Alzheimer's Association Global Biomarkers Consortium.

    PubMed

    Carrillo, Maria C; Blennow, Kaj; Soares, Holly; Lewczuk, Piotr; Mattsson, Niklas; Oberoi, Pankaj; Umek, Robert; Vandijck, Manu; Salamone, Salvatore; Bittner, Tobias; Shaw, Leslie M; Stephenson, Diane; Bain, Lisa; Zetterberg, Henrik

    2013-03-01

    Recognizing that international collaboration is critical for the acceleration of biomarker standardization efforts and the efficient development of improved diagnosis and therapy, the Alzheimer's Association created the Global Biomarkers Standardization Consortium (GBSC) in 2010. The consortium brings together representatives of academic centers, industry, and the regulatory community with the common goal of developing internationally accepted common reference standards and reference methods for the assessment of cerebrospinal fluid (CSF) amyloid β42 (Aβ42) and tau biomarkers. Such standards are essential to ensure that analytical measurements are reproducible and consistent across multiple laboratories and across multiple kit manufacturers. Analytical harmonization for CSF Aβ42 and tau will help reduce confusion in the AD community regarding the absolute values associated with the clinical interpretation of CSF biomarker results and enable worldwide comparison of CSF biomarker results across AD clinical studies. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  3. Building Cross-Country Networks for Laboratory Capacity and Improvement.

    PubMed

    Schneidman, Miriam; Matu, Martin; Nkengasong, John; Githui, Willie; Kalyesubula-Kibuuka, Simeon; Silva, Kelly Araujo

    2018-03-01

    Laboratory networks are vital to well-functioning public health systems and disease control efforts. Cross-country laboratory networks play a critical role in supporting epidemiologic surveillance, accelerating disease outbreak response, and tracking drug resistance. The East Africa Public Health Laboratory Network was established to bolster diagnostic and disease surveillance capacity. The network supports the introduction of regional quality standards; facilitates the rollout and evaluation of new diagnostic tools; and serves as a platform for training, research, and knowledge sharing. Participating facilities benefitted from state-of-the art investments, capacity building, and mentorship; conducted multicountry research studies; and contributed to disease outbreak response. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Value of laboratory tests in employer-sponsored health risk assessments for newly identifying health conditions: analysis of 52,270 participants.

    PubMed

    Kaufman, Harvey W; Williams, Fred R; Odeh, Mouneer A

    2011-01-01

    Employer-sponsored health risk assessments (HRA) may include laboratory tests to provide evidence of disease and disease risks for common medical conditions. We evaluated the ability of HRA-laboratory testing to provide new disease-risk information to participants. We performed a cross-sectional analysis of HRA-laboratory results for participating adult employees and their eligible spouses or their domestic partners, focusing on three common health conditions: hyperlipidemia, diabetes mellitus, and chronic kidney disease. HRA with laboratory results of 52,270 first-time participants were analyzed. Nearly all participants had access to health insurance coverage. Twenty-four percent (12,392) self-reported one or more of these medical conditions: 21.1% (11,017) self-identified as having hyperlipidemia, 4.7% (2,479) self-identified as having diabetes, and 0.7% (352) self-identified as having chronic kidney disease. Overall, 36% (n = 18,540) of participants had laboratory evidence of at least one medical condition newly identified: 30.7% (16,032) had laboratory evidence of hyperlipidemia identified, 1.9% (984) had laboratory evidence of diabetes identified, and 5.5% (2,866) had laboratory evidence of chronic kidney disease identified. Of all participants with evidence of hyperlipidemia 59% (16,030 of 27,047), were newly identified through the HRA. Among those with evidence of diabetes 28% (984 of 3,463) were newly identified. The highest rate of newly identified disease risk was for chronic kidney disease: 89% (2,866 of 3,218) of participants with evidence of this condition had not self-reported it. Men (39%) were more likely than women (33%) to have at least one newly identified condition (p<0.0001). Among men, lower levels of educational achievement were associated with modestly higher rates of newly identified disease risk (p<0.0001); the association with educational achievement among women was unclear. Even among the youngest age range (20 to 29 year olds), nearly 1 in 4 participants (24%) had a newly identified risk for disease. These results support the important role of employer-sponsored laboratory testing as an integral element of HRA for identifying evidence of previously undiagnosed common medical conditions in individuals of all working age ranges, regardless of educational level and gender.

  5. Biosafety and biosecurity in veterinary laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finley, Melissa R.; Astuto-Gribble, Lisa M.; Brass, Van Hildren

    Here, with recent outbreaks of MERS-Cov, Anthrax, Nipah, and Highly Pathogenic Avian Influenza, much emphasis has been placed on rapid identification of infectious agents globally. As a result, laboratories are building capacity, conducting more advanced and sophisticated research, increasing laboratory staff, and establishing collections of dangerous pathogens in an attempt to reduce the impact of infectious disease outbreaks and characterize disease causing agents. With this expansion, the global laboratory community has started to focus on laboratory biosafety and biosecurity to prevent the accidental and/or intent ional release o f these agents. Laboratory biosafety and biosecurity systems are used around themore » world to help mit igate the risks posed by dangerous pathogens in the laboratory. Veterinary laboratories carry unique responsibilities to workers and communities to safely and securely handle disease causing microorganisms. Many microorganisms studied in veterinary laboratories not only infect animals, but also have the potential to infect humans. This paper will discuss the fundamentals of laboratory biosafety and biosecurity.« less

  6. [Mobile laboratories for rapid deployment and their contribution to the containment of emerging diseases in Sub-Saharan Africa, illustrated by the example of Ebola virus disease].

    PubMed

    Diers, J; Kouriba, B; Ladan Fofana, L; Fleischmann, E; Starke, M; Diallo, S; Babin, F-X; von Bonin, J; Wölfel, R

    2015-01-01

    The Ebola virus, which became a global health concern in 2014, is an example of an emerging pathogen. Ebola virus disease can only be diagnosed in biosafety level 3 and 4 laboratories, which provide the security required to avoid exposure of both the staff and the environment to the pathogen. These laboratories are often far from the site of outbreaks, which may occur in rural areas or border regions (when the disease is imported from a neighboring country). Rapidly deployable laboratory units can bring the diagnosis closer to the outbreak site and thus significantly shorten the time to delivery of results, thus facilitating epidemic containment. Here we report our experience from the first months of implementation in Mali of a mobile laboratory unit of the same type as the European mobile labs and we describe the workflow in the laboratory as well as the training of its Malian staff. Based on our experience and the reports of other projects, we propose a framework in which these mobile laboratory units can strengthen epidemiological surveillance and contribute to containing outbreaks of emerging diseases in sub-Saharan Africa.

  7. Effects of laboratory housing on exploratory behaviour, novelty discrimination and spatial reference memory in a subterranean, solitary rodent, the Cape mole-rat (Georychus capensis).

    PubMed

    Oosthuizen, Maria Kathleen; Scheibler, Anne-Gita; Bennett, Nigel Charles; Amrein, Irmgard

    2013-01-01

    A large number of laboratory and field based studies are being carried out on mole-rats, both in our research group and others. Several studies have highlighted the development of adverse behaviours in laboratory animals and have emphasised the importance of enrichment for captive animals. Hence we were interested in evaluating how laboratory housing would affect behavioural performance in mole-rats. We investigated exploratory behaviour, the ability to discriminate between novel and familiar environments and reference memory in the solitary Cape mole-rat (Georychus capensis). Our data showed that both wild and captive animals readily explore open spaces and tunnels. Wild animals were however more active than their captive counterparts. In the Y maze two trial discrimination task, wild animals failed to discriminate between novel and familiar environments, while laboratory housed mole-rats showed preferential spatial discrimination in terms of the length of time spent in the novel arm. The performance of the laboratory and wild animals were similar when tested for reference memory in the Y maze, both groups showed a significant improvement compared to the first day, from the 3rd day onwards. Wild animals made more mistakes whereas laboratory animals were slower in completing the task. The difference in performance between wild and laboratory animals in the Y-maze may be as a result of the lower activity of the laboratory animals. Laboratory maintained Cape mole-rats show classic behaviours resulting from a lack of stimulation such as reduced activity and increased aggression. However, they do display an improved novelty discrimination compared to the wild animals. Slower locomotion rate of the laboratory animals may increase the integration time of stimuli, hence result in a more thorough inspection of the surroundings. Unlike the captive animals, wild animals show flexibility in their responses to unpredictable events, which is an important requirement under natural living conditions.

  8. Effects of Laboratory Housing on Exploratory Behaviour, Novelty Discrimination and Spatial Reference Memory in a Subterranean, Solitary Rodent, the Cape Mole-Rat (Georychus capensis)

    PubMed Central

    Oosthuizen, Maria Kathleen; Scheibler, Anne-Gita; Charles Bennett, Nigel; Amrein, Irmgard

    2013-01-01

    A large number of laboratory and field based studies are being carried out on mole-rats, both in our research group and others. Several studies have highlighted the development of adverse behaviours in laboratory animals and have emphasised the importance of enrichment for captive animals. Hence we were interested in evaluating how laboratory housing would affect behavioural performance in mole-rats. We investigated exploratory behaviour, the ability to discriminate between novel and familiar environments and reference memory in the solitary Cape mole-rat ( Georychus capensis ). Our data showed that both wild and captive animals readily explore open spaces and tunnels. Wild animals were however more active than their captive counterparts. In the Y maze two trial discrimination task, wild animals failed to discriminate between novel and familiar environments, while laboratory housed mole-rats showed preferential spatial discrimination in terms of the length of time spent in the novel arm. The performance of the laboratory and wild animals were similar when tested for reference memory in the Y maze, both groups showed a significant improvement compared to the first day, from the 3rd day onwards. Wild animals made more mistakes whereas laboratory animals were slower in completing the task. The difference in performance between wild and laboratory animals in the Y-maze may be as a result of the lower activity of the laboratory animals. Laboratory maintained Cape mole-rats show classic behaviours resulting from a lack of stimulation such as reduced activity and increased aggression. However, they do display an improved novelty discrimination compared to the wild animals. Slower locomotion rate of the laboratory animals may increase the integration time of stimuli, hence result in a more thorough inspection of the surroundings. Unlike the captive animals, wild animals show flexibility in their responses to unpredictable events, which is an important requirement under natural living conditions. PMID:24040422

  9. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE PAGES

    Varga, Z.; Mayer, K.; Bonamici, C. E.; ...

    2015-05-11

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  10. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varga, Z.; Mayer, K.; Bonamici, C. E.

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  11. False negative PCR despite high levels of JC virus DNA in spinal fluid: Implications for diagnostic testing

    PubMed Central

    Landry, Marie L.; Eid, Tore; Bannykh, Serguei; Major, Eugene

    2009-01-01

    Genome amplification methods such as polymerase chain reaction (PCR) have revolutionized our ability to detect viruses in spinal fluids of patients with neurologic diseases. It is not as well appreciated among clinicians that PCR protocols, quality assurance, and technical expertise vary significantly among laboratories. In a multi-laboratory blinded study of herpes simplex virus PCR, the most widely used and best validated CSF PCR assay, low-level positives were often missed and false positives were not uncommon [Schloss L, van Loon AM, Cinque P, Cleator G, Echevarria JM, Falk KI, et al. An international external quality assessment of nucleic acid amplification of herpes simplex virus. J Clin Virol 2003;28(2):175–85]. In addition, genome variability and mutations, which are increasingly recognized for a number of different viruses, can lead to falsely low or negative results. Both clinicians and laboratories must recognize the limitations of PCR, since misleading results may have serious consequences. We present here a case of a rapidly progressive, fatal neurologic illness in a young mother, whose CSF JCV DNA PCR at a reference laboratory was falsely negative. Ultimately, brain biopsy established the diagnosis of progressive multifocal leukoencephalopathy (PML). Repeat PCR testing of the same CSF targeting a different region of the genome yielded a high positive result. PMID:18701345

  12. Accuracy of a point-of-care ELISA test kit for predicting the presence of protective canine parvovirus and canine distemper virus antibody concentrations in dogs.

    PubMed

    Litster, A L; Pressler, B; Volpe, A; Dubovi, E

    2012-08-01

    Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  14. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  15. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  16. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  17. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  18. [Subclinical hyperthyroidism].

    PubMed

    Feldkamp, J

    2013-10-01

    Subclinical hyperthyroidism is defined as abnormal low TSH level with thyroid hormones within their reference range. This laboratory condition may be symptomatic in a relevant number of patients leading to tachycardia, sweating, nervousness, anxiety and insomnia. The risk for cardiovascular disease is increased with more frequent atrial fibrillation and increased left ventricular mass including diastolic dysfunction. Cardiovascular mortality and overall mortality surmounts the average of the normal population. Longterm TSH suppression leads to decreased bone mineral density and an increased fracture rate in the hip and in the spine. After evaluation of underlying causes, therapy should be considered, especially if TSH levels are below 0.1 mIU/l. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    PubMed

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  20. DOE research and development report. Progress report, October 1980-September 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, Carleton D.

    The DOE New Brunswick Laboratory (NBL) is the US Government's Nuclear Materials Standards and Measurement Laboratory. NBL is assigned the mission to provide and maintain, as an essential part of federal statutory responsibilities related to national and international safeguards of nuclear materials for USA defense and energy programs, an ongoing capability for: the development, preparation, certification, and distribution of reference materials for the calibration and standardization of nuclear materials measurements; the development, improvement, and evaluation of nuclear materials measurement technology; the assessment and evaluation of the practice and application of nuclear materials measurement technology; expert and reliable specialized nuclear materialsmore » measurement services for the government; and technology exchange and training in nuclear materials measurement and standards. Progress reports for this fiscal year are presented under the following sections: (1) development or evaluation of measurement technology (elemental assay of uranium plutonium; isotope composition); (2) standards and reference materials (NBL standards and reference materials; NBS reference materials); and (3) evaluation programs (safeguards analytical laboratory evaluation; general analytical evaluation program; other evaluation programs).« less

  1. Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.

    PubMed

    Haeckel, Rainer; Wosniok, Werner

    2009-01-01

    Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.

  2. Importance of clinical microbiologists for U.S. healthcare infrastructure.

    PubMed

    Carvalho, John

    2011-01-01

    Clinical microbiologists are highly skilled scientists within national hospitals and reference laboratories who diagnose patients with infections by emerging pathogens. Most advanced training for clinical microbiologists occurs at universities, where an individual can receive certification as a "Medical Laboratory Scientist" (MLS). Unfortunately, many MLS programs have closed in the United States and this has caused a shortage of clinical microbiologists at U.S. hospitals and reference laboratories. This paper explores the present crisis in MLS training and its ramifications for the emergence of antibiotic-resistant bacteria, the economics of hospitals, and the overall health of the nation, and provides resolutions for better public health policy with respect to MLS education.

  3. Photovoltaic Calibrations at the National Renewable Energy Laboratory and Uncertainty Analysis Following the ISO 17025 Guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, Keith

    The measurement of photovoltaic (PV) performance with respect to reference conditions requires measuring current versus voltage for a given tabular reference spectrum, junction temperature, and total irradiance. This report presents the procedures implemented by the PV Cell and Module Performance Characterization Group at the National Renewable Energy Laboratory (NREL) to achieve the lowest practical uncertainty. A rigorous uncertainty analysis of these procedures is presented, which follows the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement. This uncertainty analysis is required for the team’s laboratory accreditation under ISO standard 17025, “General Requirements for the Competence ofmore » Testing and Calibration Laboratories.” The report also discusses additional areas where the uncertainty can be reduced.« less

  4. [Two patients with mitochondrial respiratory chain disease].

    PubMed

    Bangma, H R; Smit, G P A; Kuks, J B M; Grevink, R G; Wolffenbuttel, B H R

    2008-10-18

    A 23-year-old woman and a 13-year-old boy were diagnosed with mitochondrial respiratory chain disease. The woman had muscle pain, fatigue and bilateral ophthalmoplegia--symptoms consistent with Kearns-Sayre syndrome. The boy had aspecific symptoms; eventually, reduced activity of complex 1 was found to be the cause of the mitochondrial respiratory chain disease in the boy and his mother, who had suffered from unexplained fatigue and muscle pain for 15 years. Mitochondrial diseases often involve several organ systems. Diagnosis can be difficult, because laboratory tests such as serum and urinary lactate and creatine kinase have low sensitivity and specificity. Biochemical assessment of muscle biopsy can reveal reduced oxidation ATP synthesis and sometimes specific abnormalities in individual protein complexes. DNA analysis may be helpful in demonstrating mitochondrial or nuclear mutations or deletions. The goal of treatment is to increase mitochondrial ATP production, improve clinical symptoms and enhance stamina. Replacement of the following substances (also referred to as cofactors) may be attempted: co-enzyme Q10, antioxidants (lipoic acid, vitamins C and E), riboflavin, thiamine, creatine and carnitine. Evidence regarding the optimal treatment approach is lacking; one usually has to rely on observing effects in the individual patient.

  5. 33 CFR 209.340 - Laboratory investigations and materials testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... hydraulic laboratories, and to the Inter-Agency Sedimentation Project. (c) References. (1) AR 37-20. (2) AR... ordinary business channels. (3) Performance of the work will not interfere with provisions of services... with the same procedures as apply to Division Materials Laboratories. (3) Inter-Agency Sedimentation...

  6. 33 CFR 209.340 - Laboratory investigations and materials testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... hydraulic laboratories, and to the Inter-Agency Sedimentation Project. (c) References. (1) AR 37-20. (2) AR... ordinary business channels. (3) Performance of the work will not interfere with provisions of services... with the same procedures as apply to Division Materials Laboratories. (3) Inter-Agency Sedimentation...

  7. Detection of borreliae in archived sera from patients with clinically suspect Lyme disease.

    PubMed

    Lee, Sin Hang; Vigliotti, Jessica S; Vigliotti, Veronica S; Jones, William; Shearer, David M

    2014-03-11

    The diagnoses of Lyme disease based on clinical manifestations, serological findings and detection of infectious agents often contradict each other. We tested 52 blind-coded serum samples, including 20 pre-treatment and 12 post-treatment sera from clinically suspect Lyme disease patients, for the presence of residual Lyme disease infectious agents, using nested PCR amplification of a signature segment of the borrelial 16S ribosomal RNA gene for detection and direct DNA sequencing of the PCR amplicon for molecular validation. These archived sera were split from the samples drawn for the 2-tier serology tests performed by a CDC-approved laboratory, and are used as reference materials for evaluating new diagnostic reagents. Of the 12 post-treatment serum samples, we found DNA evidence of a novel borrelia of uncertain significance in one, which was also positive for the 2-tier serology test. The rest of the post-treatment sera and all 20 control sera were PCR-negative. Of the 20 pre-treatment sera from clinically suspect early Lyme disease patients, we found Borrelia miyamotoi in one which was 2-tier serology-negative, and a Borrelia burgdorferi in two-one negative and one positive for 2-tier serology. We conclude that a sensitive and reliable DNA-based test is needed to support the diagnosis of Lyme disease and Lyme disease-like borreliosis.

  8. Insulin resistance and coronary artery disease in non-diabetic patients: Is there any correlation?

    PubMed

    Vafaeimanesh, Jamshid; Parham, Mahmoud; Norouzi, Samieh; Hamednasimi, Parinaz; Bagherzadeh, Mohammad

    2018-01-01

    Cardiovascular diseases are the most common causes of death in the world and type 2 diabetes is one of them because it is highly prevalent and doubles heart disease risk. Some studies suggest that insulin resistance is associated with coronary artery disease in non-diabetics. The aim of this study was to evaluate the association of insulin resistance (IR) and coronary artery disease (CAD) in non-diabetic patients. In this cross-sectional study, from September 2014 to July 2015, 120 patients referring to Shahid Beheshti Hospital of Qom were evaluated. Their medical history, baseline laboratory studies, BMI and GFR were recorded. After 8 hours of fasting, blood samples were taken from the patients at 8 am, including fasting glucose and insulin level. We estimated insulin resistance using the homeostatic model assessment index of IR (HOMA-IR). Finally, we evaluated the association between IR and CAD. Totally, 120 patients were assigned to participate in this study, among them, 50 patients without CAD and 70 with coronary artery stenosis. Insulin resistance (HOMA-IR> 2.5) was positive in 59 (49.3%) patients and negative in 61 (50.7%) patients. Hence, the correlation between IR and CAD was not statistically significant (P=0.9). In this study, although the correlation was not found between insulin resistance and coronary heart disease, among men, we found a significant association between coronary heart disease and insulin resistance.

  9. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  10. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  11. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  12. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or concomitantly according to written standard operating procedures, which provide for periodic...) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  13. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  14. Clinical and Virological Study of Dengue Cases and the Members of Their Households: The Multinational DENFRAME Project

    PubMed Central

    Dussart, Philippe; Baril, Laurence; Petit, Laure; Beniguel, Lydie; Quang, Luong Chan; Ly, Sowath; Azevedo, Raimunda do Socorro Silva; Meynard, Jean-Baptiste; Vong, Sirenda; Chartier, Loïc; Diop, Aba; Sivuth, Ong; Duong, Veasna; Thang, Cao Minh; Jacobs, Michael; Sakuntabhai, Anavaj; Nunes, Marcio Roberto Teixeira; Huong, Vu Ti Que; Buchy, Philippe; Vasconcelos, Pedro Fernando da Costa

    2012-01-01

    Background Dengue has emerged as the most important vector-borne viral disease in tropical areas. Evaluations of the burden and severity of dengue disease have been hindered by the frequent lack of laboratory confirmation and strong selection bias toward more severe cases. Methodology A multinational, prospective clinical study was carried out in South-East Asia (SEA) and Latin America (LA), to ascertain the proportion of inapparent dengue infections in households of febrile dengue cases, and to compare clinical data and biological markers from subjects with various dengue disease patterns. Dengue infection was laboratory-confirmed during the acute phase, by virus isolation and detection of the genome. The four participating reference laboratories used standardized methods. Principal Findings Among 215 febrile dengue subjects—114 in SEA and 101 in LA—28 (13.0%) were diagnosed with severe dengue (from SEA only) using the WHO definition. Household investigations were carried out for 177 febrile subjects. Among household members at the time of the first home visit, 39 acute dengue infections were detected of which 29 were inapparent. A further 62 dengue cases were classified at early convalescent phase. Therefore, 101 dengue infections were found among the 408 household members. Adding these together with the 177 Dengue Index Cases, the overall proportion of dengue infections among the study participants was estimated at 47.5% (278/585; 95% CI 43.5–51.6). Lymphocyte counts and detection of the NS1 antigen differed significantly between inapparent and symptomatic dengue subjects; among inapparent cases lymphocyte counts were normal and only 20% were positive for NS1 antigen. Primary dengue infection and a specific dengue virus serotype were not associated with symptomatic dengue infection. Conclusion Household investigation demonstrated a high proportion of household members positive for dengue infection, including a number of inapparent cases, the frequency of which was higher in SEA than in LA. PMID:22292098

  15. Improved reliability of serological tools for the diagnosis of West Nile fever in horses within Europe

    PubMed Central

    Lowenski, Steeve; Durand, Benoit; Bahuon, Céline; Zientara, Stéphan; Lecollinet, Sylvie

    2017-01-01

    West Nile Fever is a zoonotic disease caused by a mosquito-borne flavivirus, WNV. By its clinical sensitivity to the disease, the horse is a useful sentinel of infection. Because of the virus’ low-level, short-term viraemia in horses, the primary tools used to diagnose WNV are serological tests. Inter-laboratory proficiency tests (ILPTs) were held in 2010 and 2013 to evaluate WNV serological diagnostic tools suited for the European network of National Reference Laboratories (NRLs) for equine diseases. These ILPTs were designed to evaluate the laboratories’ and methods’ performances in detecting WNV infection in horses through serology. The detection of WNV immunoglobulin G (IgG) antibodies by ELISA is widely used in Europe, with 17 NRLs in 2010 and 20 NRLs in 2013 using IgG WNV assays. Thanks to the development of new commercial IgM capture kits, WNV IgM capture ELISAs were rapidly implemented in NRLs between 2010 (4 NRLs) and 2013 (13 NRLs). The use of kits allowed the quick standardisation of WNV IgG and IgM detection assays in NRLs with more than 95% (20/21) and 100% (13/13) of satisfactory results respectively in 2013. Conversely, virus neutralisation tests (VNTs) were implemented in 33% (7/21) of NRLs in 2013 and their low sensitivity was evidenced in 29% (2/7) of NRLs during this ILPT. A comparison of serological diagnostic methods highlighted the higher sensitivity of IgG ELISAs compared to WNV VNTs. They also revealed that the low specificity of IgG ELISA kits meant that it could detect animals infected with other flaviviruses. In contrast VNT and IgM ELISA assays were highly specific and did not detect antibodies against related flaviviruses. These results argue in favour of the need for and development of new, specific serological diagnostic assays that could be easily transferred to partner laboratories. PMID:28915240

  16. Whole-body transcriptome of selectively bred, resistant-, control-, and susceptible-line rainbow trout following experimental challenge with Flavobacterium psychrophilum

    PubMed Central

    Marancik, David; Gao, Guangtu; Paneru, Bam; Ma, Hao; Hernandez, Alvaro G.; Salem, Mohamed; Yao, Jianbo; Palti, Yniv; Wiens, Gregory D.

    2014-01-01

    Genetic improvement for enhanced disease resistance in fish is an increasingly utilized approach to mitigate endemic infectious disease in aquaculture. In domesticated salmonid populations, large phenotypic variation in disease resistance has been identified but the genetic basis for altered responsiveness remains unclear. We previously reported three generations of selection and phenotypic validation of a bacterial cold water disease (BCWD) resistant line of rainbow trout, designated ARS-Fp-R. This line has higher survival after infection by either standardized laboratory challenge or natural challenge as compared to two reference lines, designated ARS-Fp-C (control) and ARS-Fp-S (susceptible). In this study, we utilized 1.1 g fry from the three genetic lines and performed RNA-seq to measure transcript abundance from the whole body of naive and Flavobacterium psychrophilum infected fish at day 1 (early time-point) and at day 5 post-challenge (onset of mortality). Sequences from 24 libraries were mapped onto the rainbow trout genome reference transcriptome of 46,585 predicted protein coding mRNAs that included 2633 putative immune-relevant gene transcripts. A total of 1884 genes (4.0% genome) exhibited differential transcript abundance between infected and mock-challenged fish (FDR < 0.05) that included chemokines, complement components, tnf receptor superfamily members, interleukins, nod-like receptor family members, and genes involved in metabolism and wound healing. The largest number of differentially expressed genes occurred on day 5 post-infection between naive and challenged ARS-Fp-S line fish correlating with high bacterial load. After excluding the effect of infection, we identified 21 differentially expressed genes between the three genetic lines. In summary, these data indicate global transcriptome differences between genetic lines of naive animals as well as differentially regulated transcriptional responses to infection. PMID:25620978

  17. Impact of intermittent fasting on health and disease processes.

    PubMed

    Mattson, Mark P; Longo, Valter D; Harvie, Michelle

    2017-10-01

    Humans in modern societies typically consume food at least three times daily, while laboratory animals are fed ad libitum. Overconsumption of food with such eating patterns often leads to metabolic morbidities (insulin resistance, excessive accumulation of visceral fat, etc.), particularly when associated with a sedentary lifestyle. Because animals, including humans, evolved in environments where food was relatively scarce, they developed numerous adaptations that enabled them to function at a high level, both physically and cognitively, when in a food-deprived/fasted state. Intermittent fasting (IF) encompasses eating patterns in which individuals go extended time periods (e.g., 16-48h) with little or no energy intake, with intervening periods of normal food intake, on a recurring basis. We use the term periodic fasting (PF) to refer to IF with periods of fasting or fasting mimicking diets lasting from 2 to as many as 21 or more days. In laboratory rats and mice IF and PF have profound beneficial effects on many different indices of health and, importantly, can counteract disease processes and improve functional outcome in experimental models of a wide range of age-related disorders including diabetes, cardiovascular disease, cancers and neurological disorders such as Alzheimer's disease Parkinson's disease and stroke. Studies of IF (e.g., 60% energy restriction on 2days per week or every other day), PF (e.g., a 5day diet providing 750-1100kcal) and time-restricted feeding (TRF; limiting the daily period of food intake to 8h or less) in normal and overweight human subjects have demonstrated efficacy for weight loss and improvements in multiple health indicators including insulin resistance and reductions in risk factors for cardiovascular disease. The cellular and molecular mechanisms by which IF improves health and counteracts disease processes involve activation of adaptive cellular stress response signaling pathways that enhance mitochondrial health, DNA repair and autophagy. PF also promotes stem cell-based regeneration as well as long-lasting metabolic effects. Randomized controlled clinical trials of IF versus PF and isoenergetic continuous energy restriction in human subjects will be required to establish the efficacy of IF in improving general health, and preventing and managing major diseases of aging. Published by Elsevier B.V.

  18. [Results transferability on RXL, ARX, X-Pand, BN2 (Dade Behring) and modular DP (Roche Diagnostics) analysers: application to component assays of fibrotest and Actitest].

    PubMed

    Imbert-Bismut, F; Messous, D; Raoult, A; Poynard, T; Bertrand, J J; Marie, P A; Louis, V; Audy, C; Thouy, J M; Hainque, B; Piton, A

    2005-01-01

    The follow up of patients with chronic liver diseases and the data from multicentric clinical studies are affected by the variability of assay results for the same parameter between the different laboratories. Today, the main objective in clinical chemistry throughout the world is to harmonise the assay results between the laboratories after the confirmation of their traceability, in relation to defined reference systems. In this context, the purpose of our study was to verify the homogeneity of haptoglobin, apolipoprotein A1, total bilirubin, GGT activity, ALAT activity results, which are combined in Fibrotest and Actitest, between Dimension Analysers RXL, ARX and X-PAND (Dade Behring Society). Moreover, we verified the transferability of Fibrotest and Actitest results between the RXL, and either the BN2 (haptoglobin and apolipoprotein A1) or the Modular DP (total bilirubin, GGT and ALAT activity concentrations). The serum samples from 150 hospitalised patients were analysed on the different analysers. Specific protein assays were calibrated using solutions standardised against reference material on Dimension and BN2 analysers. Total bilirubin assays were performed by a diazoreaction on Dimension and Modular DP analysers. The GGT and ALAT activity measurements on the Dimension analysers were performed in accordance with the reference methods defined by the International Federation of Clinical Chemisty and Laboratory Medicine (IFCC). On the Modular, enzyme activity measurements were performed according to the Szasz method (L-gamma- glutamyl-4-nitroanilide as substrate) modified by Persijn and van der Slik (L-gamma- glutamyl-3-carboxy- 4-nitroanilide as substrat) for GGT and according to the IFCC specifications for ALAT. The methods of enzymatic activity measurement were calibrated on the Modular only. Liver fibrosis and necroinflammatory activity indices were determined using calculation algorithms, after having adjusted each component's result of Fibrotest and Actitest for gender and age. Our study has shown, for each parameter, harmonious results between the Dimension analysers and between RXL and BN2- Modular DP. Disregarding alpha-2 macroglobulin which cannot be assayed on RXL, the results of Fibrotest and Actitest were similar as performed on BN2- Modular DP and RXL.

  19. 40 CFR 792.107 - Test, control, and reference substance handling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test, control, and reference substance handling. 792.107 Section 792.107 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference...

  20. Leptospirosis Outbreak in Sri Lanka in 2008: Lessons for Assessing the Global Burden of Disease

    PubMed Central

    Agampodi, Suneth B.; Peacock, Sharon J.; Thevanesam, Vasanthi; Nugegoda, Danaseela B.; Smythe, Lee; Thaipadungpanit, Janjira; Craig, Scott B.; Burns, Mary Ann; Dohnt, Michael; Boonsilp, Siriphan; Senaratne, Thamarasi; Kumara, Athula; Palihawadana, Paba; Perera, Sahan; Vinetz, Joseph M.

    2011-01-01

    Global leptospirosis disease burden estimates are hampered by the lack of scientifically sound data from countries with probable high endemicity and limited diagnostic capacities. We describe the seroepidemiologic and clinical characteristics of the leptospirosis outbreak in 2008 in Sri Lanka. Definitive/presumptive case definitions proposed by the World Health Organization Leptospirosis Epidemiology Reference Group were used for case confirmation. Of the 404 possible cases, 155 were confirmed to have leptospirosis. Highest titers of patient seum samples reacted with serovars Pyrogenes (28.7%), Hardjo (18.8%), Javanica (11.5%), and Hebdomadis (11.5%). Sequencing of the 16S ribosomal DNA gene identified six infections: five with Leptospira interrogans and one with L. weilli. In this patient population, acute renal failure was the main complication (14.8%), followed by myocarditis (7.1%) and heart failure (3.9%). The case-fatality rate was 1.3%. This report strengthens the urgent need for increasing laboratory diagnostic capabilities to determine the causes of epidemic and endemic infectious diseases in Sri Lanka, a finding relevant to other tropical regions. PMID:21896807

Top