Sample records for dispatchable pv peak

  1. Development and implementation of a dynamic TES dispatch control component in a PV-CSP techno-economic performance modelling tool

    NASA Astrophysics Data System (ADS)

    Hansson, Linus; Guédez, Rafael; Larchet, Kevin; Laumert, Bjorn

    2017-06-01

    The dispatchability offered by thermal energy storage (TES) in concentrated solar power (CSP) and solar hybrid plants based on such technology presents the most important difference compared to power generation based only on photovoltaics (PV). This has also been one reason for recent hybridization efforts of the two technologies and the creation of Power Purchase Agreement (PPA) payment schemes based on offering higher payment multiples during daily hours of higher (peak or priority) demand. Recent studies involving plant-level thermal energy storage control strategies are however to a large extent based on pre-determined approaches, thereby not taking into account the actual dynamics of thermal energy storage system operation. In this study, the implementation of a dynamic dispatch strategy in the form of a TRNSYS controller for hybrid PV-CSP plants in the power-plant modelling tool DYESOPT is presented. In doing this it was attempted to gauge the benefits of incorporating a day-ahead approach to dispatch control compared to a fully pre-determined approach determining hourly dispatch only once prior to annual simulation. By implementing a dynamic strategy, it was found possible to enhance technical and economic performance for CSP-only plants designed for peaking operation and featuring low values of the solar multiple. This was achieved by enhancing dispatch control, primarily by taking storage levels at the beginning of every simulation day into account. The sequential prediction of the TES level could therefore be improved, notably for evaluated plants without integrated PV, for which the predicted storage levels deviated less than when PV was present in the design. While also featuring dispatch performance gains, optimal plant configurations for hybrid PV-CSP was found to present a trade-off in economic performance in the form of an increase in break-even electricity price when using the dynamic strategy which was offset to some extent by a reduction in upfront investment cost. An increase in turbine starts for the implemented strategy however highlights that this is where further improvements can be made.

  2. Economic Analysis Case Studies of Battery Energy Storage with SAM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiOrio, Nicholas; Dobos, Aron; Janzou, Steven

    2015-11-01

    Interest in energy storage has continued to increase as states like California have introduced mandates and subsidies to spur adoption. This energy storage includes customer sited behind-the-meter storage coupled with photovoltaics (PV). This paper presents case study results from California and Tennessee, which were performed to assess the economic benefit of customer-installed systems. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. Themore » analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued.« less

  3. Air Quality Improvements of Increased Integration of Renewables: Solar Photovoltaics Penetration Scenarios

    NASA Astrophysics Data System (ADS)

    Duran, P.; Holloway, T.; Brinkman, G.; Denholm, P.; Littlefield, C. M.

    2011-12-01

    Solar photovoltaics (PV) are an attractive technology because they can be locally deployed and tend to yield high production during periods of peak electric demand. These characteristics can reduce the need for conventional large-scale electricity generation, thereby reducing emissions of criteria air pollutants (CAPs) and improving ambient air quality with regard to such pollutants as nitrogen oxides, sulfur oxides and fine particulates. Such effects depend on the local climate, time-of-day emissions, available solar resources, the structure of the electric grid, and existing electricity production among other factors. This study examines the air quality impacts of distributed PV across the United States Eastern Interconnection. In order to accurately model the air quality impact of distributed PV in space and time, we used the National Renewable Energy Lab's (NREL) Regional Energy Deployment System (ReEDS) model to form three unique PV penetration scenarios in which new PV construction is distributed spatially based upon economic drivers and natural solar resources. Those scenarios are 2006 Eastern Interconnection business as usual, 10% PV penetration, and 20% PV penetration. With the GridView (ABB, Inc) dispatch model, we used historical load data from 2006 to model electricity production and distribution for each of the three scenarios. Solar PV electric output was estimated using historical weather data from 2006. To bridge the gap between dispatch and air quality modeling, we will create emission profiles for electricity generating units (EGUs) in the Eastern Interconnection from historical Continuous Emissions Monitoring System (CEMS) data. Via those emissions profiles, we will create hourly emission data for EGUs in the Eastern Interconnect for each scenario during 2006. Those data will be incorporated in the Community Multi-scale Air Quality (CMAQ) model using the Sparse Matrix Operator Kernel Emissions (SMOKE) model. Initial results indicate that PV penetration significantly reduces conventional peak electricity production and that, due to reduced emissions during periods of extremely active photochemistry, air quality could see benefits.

  4. Optimization of joint energy micro-grid with cold storage

    NASA Astrophysics Data System (ADS)

    Xu, Bin; Luo, Simin; Tian, Yan; Chen, Xianda; Xiong, Botao; Zhou, Bowen

    2018-02-01

    To accommodate distributed photovoltaic (PV) curtailment, to make full use of the joint energy micro-grid with cold storage, and to reduce the high operating costs, the economic dispatch of joint energy micro-grid load is particularly important. Considering the different prices during the peak and valley durations, an optimization model is established, which takes the minimum production costs and PV curtailment fluctuations as the objectives. Linear weighted sum method and genetic-taboo Particle Swarm Optimization (PSO) algorithm are used to solve the optimization model, to obtain optimal power supply output. Taking the garlic market in Henan as an example, the simulation results show that considering distributed PV and different prices in different time durations, the optimization strategies are able to reduce the operating costs and accommodate PV power efficiently.

  5. Exploring the Potential Competitiveness of Utility-Scale Photovoltaics plus Batteries with Concentrating Solar Power, 2015–2030

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, David; Margolis, Robert; Denholm, Paul

    Declining costs of both solar photovoltaics (PV) and battery storage have raised interest in the creation of “solar-plus-storage” systems to provide dispatchable energy and reliable capacity. There has been limited deployment of PV-plus-energy storage systems (PV+ESS), and the actual configuration and performance of these systems for dispatchable energy are in the early stages of being defined. In contrast, concentrating solar power with thermal energy storage (CSP+TES) has been deployed at scale with the proven capability of providing a dispatchable, reliable source of renewable generation. A key question moving forward is how to compare the relative costs and benefits of PV+ESSmore » and CSP+TES. While both technologies collect solar radiation and produce electricity, they do so through very different mechanisms, which creates challenges for direct comparison. Nonetheless, it is important to establish a framework for comparison and to identify cost and performance targets to aid meeting the nation’s goals for clean energy deployment. In this paper, we provide a preliminary assessment comparing the cost of energy from CSP+TES and PV+ESS that focuses on a single metric: levelized cost of energy (LCOE). We begin by defining the configuration of each system, which is particularly important for PV+ESS systems. We then examine a range of projected cost declines for PV, batteries, and CSP. Finally, we summarize the estimated LCOE over a range of configuration and cost estimates. We conclude by acknowledging that differences in these technologies present challenges for comparison using a single performance metric. We define systems with similar configurations in some respects. In reality, because of inherent differences in CSP+TES and PV+ESS systems, they will provide different grid services and different value. For example, depending on its configuration, a PV+ESS system may provide additional value over CSP+TES by providing more flexible operation, including certain ancillary services and the ability to store off-peak grid energy. Alternatively, direct thermal energy storage allows a greater capture of solar energy, reducing the potential for curtailments in very high solar scenarios. So while this analysis evaluates a key performance metric (cost per unit of generation) under a range of cost projections, additional analysis of the value per unit of generation will be needed to comprehensively assess the relative competitiveness of solar energy systems deployed with energy storage.« less

  6. Technoeconomic Modeling of Battery Energy Storage in SAM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiOrio, Nicholas; Dobos, Aron; Janzou, Steven

    Detailed comprehensive lead-acid and lithium-ion battery models have been integrated with photovoltaic models in an effort to allow System Advisor Model (SAM) to offer the ability to predict the performance and economic benefit of behind the meter storage. In a system with storage, excess PV energy can be saved until later in the day when PV production has fallen, or until times of peak demand when it is more valuable. Complex dispatch strategies can be developed to leverage storage to reduce energy consumption or power demand based on the utility rate structure. This document describes the details of the batterymore » performance and economic models in SAM.« less

  7. Boosting CSP Production with Thermal Energy Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, P.; Mehos, M.

    2012-06-01

    Combining concentrating solar power (CSP) with thermal energy storage shows promise for increasing grid flexibility by providing firm system capacity with a high ramp rate and acceptable part-load operation. When backed by energy storage capability, CSP can supplement photovoltaics by adding generation from solar resources during periods of low solar insolation. The falling cost of solar photovoltaic (PV) - generated electricity has led to a rapid increase in the deployment of PV and projections that PV could play a significant role in the future U.S. electric sector. The solar resource itself is virtually unlimited; however, the actual contribution of PVmore » electricity is limited by several factors related to the current grid. The first is the limited coincidence between the solar resource and normal electricity demand patterns. The second is the limited flexibility of conventional generators to accommodate this highly variable generation resource. At high penetration of solar generation, increased grid flexibility will be needed to fully utilize the variable and uncertain output from PV generation and to shift energy production to periods of high demand or reduced solar output. Energy storage is one way to increase grid flexibility, and many storage options are available or under development. In this article, however, we consider a technology already beginning to be used at scale - thermal energy storage (TES) deployed with concentrating solar power (CSP). PV and CSP are both deployable in areas of high direct normal irradiance such as the U.S. Southwest. The role of these two technologies is dependent on their costs and relative value, including how their value to the grid changes as a function of what percentage of total generation they contribute to the grid, and how they may actually work together to increase overall usefulness of the solar resource. Both PV and CSP use solar energy to generate electricity. A key difference is the ability of CSP to utilize high-efficiency TES, which turns CSP into a partially dispatchable resource. The addition of TES produces additional value by shifting the delivery of solar energy to periods of peak demand, providing firm capacity and ancillary services, and reducing integration challenges. Given the dispatchability of CSP enabled by TES, it is possible that PV and CSP are at least partially complementary. The dispatchability of CSP with TES can enable higher overall penetration of the grid by solar energy by providing solar-generated electricity during periods of cloudy weather or at night, when PV-generated power is unavailable. Such systems also have the potential to improve grid flexibility, thereby enabling greater penetration of PV energy (and other variable generation sources such as wind) than if PV were deployed without CSP.« less

  8. A study on economic power dispatch grid connected PV power plant in educational institutes

    NASA Astrophysics Data System (ADS)

    Singh, Kuldip; Kumar, M. Narendra; Mishra, Satyasis

    2018-04-01

    India has main concerns on environment and escalation of fuel prices with respect to diminution of fossil fuel reserves and the major focus on renewable Energy sources for power generation to fulfill the present and future energy demand. Installation of PV power plants in the Educational Institutions has grown up drastically throughout India. More PV power plant are integrated with load and grid through net metering. Therefore, this paper is an analysis of the 75kWp PV plant at chosen buses, considering the need of minimum demand from the grid. The case study is carried out for different generation level throughout the day and year w.r.t load and climate changes, load sharing on grid. The economic dispatch model developed for PV plant integrated with Grid.

  9. Solar plus: Optimization of distributed solar PV through battery storage and dispatchable load in residential buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Shaughnessy, Eric; Cutler, Dylan; Ardani, Kristen

    As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt modelmore » is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.« less

  10. Solar plus: Optimization of distributed solar PV through battery storage and dispatchable load in residential buildings

    DOE PAGES

    O'Shaughnessy, Eric; Cutler, Dylan; Ardani, Kristen; ...

    2018-01-11

    As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt modelmore » is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.« less

  11. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants: Report Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul L.; Margolis, Robert M.; Eichman, Joshua D.

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  12. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul L.; Margolis, Robert M.; Eichman, Joshua D.

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  13. Economic dispatch optimization for system integrating renewable energy sources

    NASA Astrophysics Data System (ADS)

    Jihane, Kartite; Mohamed, Cherkaoui

    2018-05-01

    Nowadays, the use of energy is growing especially in transportation and electricity industries. However this energy is based on conventional sources which pollute the environment. Multi-source system is seen as the best solution to sustainable development. This paper proposes the Economic Dispatch (ED) of hybrid renewable power system. The hybrid system is composed of ten thermal generators, photovoltaic (PV) generator and wind turbine generator. To show the importance of renewable energy sources (RES) in the energy mix we have ran the simulation for system integrated PV only and PV plus wind. The result shows that the system with renewable energy sources (RES) is more compromising than the system without RES in terms of fuel cost.

  14. A thermal storage capacity market for non dispatchable renewable energies

    NASA Astrophysics Data System (ADS)

    Bennouna, El Ghali; Mouaky, Ammar; Arrad, Mouad; Ghennioui, Abdellatif; Mimet, Abdelaziz

    2017-06-01

    Due to the increasingly high capacity of wind power and solar PV in Germany and some other European countries and the high share of variable renewable energy resources in comparison to fossil and nuclear capacity, a power reserve market structured by auction systems was created to facilitate the exchange of balance power capacities between systems and even grid operators. Morocco has a large potential for both wind and solar energy and is engaged in a program to deploy 2000MW of wind capacity by 2020 and 3000 MW of solar capacity by 2030. Although the competitiveness of wind energy is very strong, it appears clearly that the wind program could be even more ambitious than what it is, especially when compared to the large exploitable potential. On the other hand, heavy investments on concentrated solar power plants equipped with thermal energy storage have triggered a few years ago including the launching of the first part of the Nour Ouarzazate complex, the goal being to reach stable, dispatchable and affordable electricity especially during evening peak hours. This paper aims to demonstrate the potential of shared thermal storage capacity between dispatchable and non dispatchable renewable energies and particularly CSP and wind power. Thus highlighting the importance of a storage capacity market in parallel to the power reserve market and the and how it could enhance the development of both wind and CSP market penetration.

  15. REopt Lite Web Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NREL developed a free, publicly available web version of the REopt (TM) renewable energy integration and optimization platform called REopt Lite. REopt Lite recommends the optimal size and dispatch strategy for grid-connected photovoltaics (PV) and battery storage at a site. It also allows users to explore how PV and storage can increase a site's resiliency during a grid outage.

  16. Recent advances in the PV-CSP hybrid solar power technology

    NASA Astrophysics Data System (ADS)

    Ju, Xing; Xu, Chao; Han, Xue; Zhang, Hui; Wei, Gaosheng; Chen, Lin

    2017-06-01

    Photovoltaic - Concentrated Solar Power (PV-CSP) hybrid technology is considered to be an important future research trend in solar energy engineering. The development of the PV-CSP hybrid technology accelerates in recent years with the rapid maturation of photovoltaics (PV) and concentrated solar power (CSP). This paper presents the recent advances on PV-CSP technology, including different technologies based on new dispatch strategies, Organic Rankine Cycles, spectral beam filters and so on. The research status and the hybrid system performance of the recent researches are summarized, aimed to provide an extended recognition on the PV-CSP hybrid technology. The advantages and limitations of the hybrid system are concluded according to the researches reviewed.

  17. Hybrid solar converters for maximum exergy and inexpensive dispatchable electricity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branz, Howard M.; Regan, William; Gerst, Kacy J.

    Photovoltaic (PV) solar energy systems are being deployed at an accelerating rate to supply low-carbon electricity worldwide. However, PV is unlikely to economically supply much more than 10% of the world's electricity unless there is a dramatic reduction in the cost of electricity storage. There is an important scientific and technological opportunity to address the storage challenge by developing inexpensive hybrid solar converters that collect solar heat at temperatures between about 200 and 600 °C and also incorporate PV. Since heat can be stored and converted to electricity at relatively low cost, collection of high exergy content (high temperature) solarmore » heat can provide energy that is dispatchable on demand to meet loads that are not well matched to solar insolation. However, PV cells can collect and convert much of the solar spectrum to electricity more efficiently and inexpensively than solar thermal systems. Advances in spectrum-splitting optics, high-temperature PV cells, thermal management and system design are needed for transformational hybrid converters. We propose that maximizing the exergy output from the solar converters while minimizing the cost of exergy can help propel solar energy toward a higher contribution to carbon-free electricity in the long term than the prevailing paradigm of maximizing the energy output while minimizing the cost of energy« less

  18. Solar electricity supply isolines of generation capacity and storage.

    PubMed

    Grossmann, Wolf; Grossmann, Iris; Steininger, Karl W

    2015-03-24

    The recent sharp drop in the cost of photovoltaic (PV) electricity generation accompanied by globally rapidly increasing investment in PV plants calls for new planning and management tools for large-scale distributed solar networks. Of major importance are methods to overcome intermittency of solar electricity, i.e., to provide dispatchable electricity at minimal costs. We find that pairs of electricity generation capacity G and storage S that give dispatchable electricity and are minimal with respect to S for a given G exhibit a smooth relationship of mutual substitutability between G and S. These isolines between G and S support the solving of several tasks, including the optimal sizing of generation capacity and storage, optimal siting of solar parks, optimal connections of solar parks across time zones for minimizing intermittency, and management of storage in situations of far below average insolation to provide dispatchable electricity. G-S isolines allow determining the cost-optimal pair (G,S) as a function of the cost ratio of G and S. G-S isolines provide a method for evaluating the effect of geographic spread and time zone coverage on costs of solar electricity.

  19. Solar electricity supply isolines of generation capacity and storage

    PubMed Central

    Grossmann, Wolf; Grossmann, Iris; Steininger, Karl W.

    2015-01-01

    The recent sharp drop in the cost of photovoltaic (PV) electricity generation accompanied by globally rapidly increasing investment in PV plants calls for new planning and management tools for large-scale distributed solar networks. Of major importance are methods to overcome intermittency of solar electricity, i.e., to provide dispatchable electricity at minimal costs. We find that pairs of electricity generation capacity G and storage S that give dispatchable electricity and are minimal with respect to S for a given G exhibit a smooth relationship of mutual substitutability between G and S. These isolines between G and S support the solving of several tasks, including the optimal sizing of generation capacity and storage, optimal siting of solar parks, optimal connections of solar parks across time zones for minimizing intermittency, and management of storage in situations of far below average insolation to provide dispatchable electricity. G−S isolines allow determining the cost-optimal pair (G,S) as a function of the cost ratio of G and S. G−S isolines provide a method for evaluating the effect of geographic spread and time zone coverage on costs of solar electricity. PMID:25755261

  20. Integrating Solar PV in Utility System Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, A.; Botterud, A.; Wu, J.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, andmore » day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved relative to DA forecasts, but still imperfect. Finally, we represent decisions within the operating hour by schedulers and transmission system operators as real-time (RT) balancing. We simulate the DA and HA scheduling processes with a detailed unit-commitment (UC) and economic dispatch (ED) optimization model. This model creates a least-cost dispatch and commitment plan for the conventional generating units using forecasts and reserve requirements as inputs. We consider only the generation units and load of the utility in this analysis; we do not consider opportunities to trade power with neighboring utilities. We also do not consider provision of reserves from renewables or from demand-side options. We estimate dynamic reserve requirements in order to meet reliability requirements in the RT operations, considering the uncertainty and variability in load, solar PV, and wind resources. Balancing reserve requirements are based on the 2.5th and 97.5th percentile of 1-min deviations from the HA schedule in a previous year. We then simulate RT deployment of balancing reserves using a separate minute-by-minute simulation of deviations from the HA schedules in the operating year. In the simulations we assume that balancing reserves can be fully deployed in 10 min. The minute-by-minute deviations account for HA forecasting errors and the actual variability of the load, wind, and solar generation. Using these minute-by-minute deviations and deployment of balancing reserves, we evaluate the impact of PV on system reliability through the calculation of the standard reliability metric called Control Performance Standard 2 (CPS2). Broadly speaking, the CPS2 score measures the percentage of 10-min periods in which a balancing area is able to balance supply and demand within a specific threshold. Compliance with the North American Electric Reliability Corporation (NERC) reliability standards requires that the CPS2 score must exceed 90% (i.e., the balancing area must maintain adequate balance for 90% of the 10-min periods). The combination of representing DA forecast errors in the DA commitments, using 1-min PV data to simulate RT balancing, and estimates of reliability performance through the CPS2 metric, all factors that are important to operating systems with increasing amounts of PV, makes this study unique in its scope.« less

  1. Optimal Solar PV Arrays Integration for Distributed Generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omitaomu, Olufemi A; Li, Xueping

    2012-01-01

    Solar photovoltaic (PV) systems hold great potential for distributed energy generation by installing PV panels on rooftops of residential and commercial buildings. Yet challenges arise along with the variability and non-dispatchability of the PV systems that affect the stability of the grid and the economics of the PV system. This paper investigates the integration of PV arrays for distributed generation applications by identifying a combination of buildings that will maximize solar energy output and minimize system variability. Particularly, we propose mean-variance optimization models to choose suitable rooftops for PV integration based on Markowitz mean-variance portfolio selection model. We further introducemore » quantity and cardinality constraints to result in a mixed integer quadratic programming problem. Case studies based on real data are presented. An efficient frontier is obtained for sample data that allows decision makers to choose a desired solar energy generation level with a comfortable variability tolerance level. Sensitivity analysis is conducted to show the tradeoffs between solar PV energy generation potential and variability.« less

  2. On the Path to SunShot. Advancing Concentrating Solar Power Technology, Performance, and Dispatchability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehos, Mark; Turchi, Craig; Jorgenson, Jennie

    2016-05-01

    This report examines the remaining challenges to achieving the competitive concentrating solar power (CSP) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Although CSP costs continue to decline toward SunShot targets, CSP acceptance and deployment have been hindered by inexpensive photovoltaics (PV). However, a recent analysis found that thermal energy storage (TES) could increase CSP's value--based on combined operational and capacity benefits--by up to 6 cents/kWh compared to variable-generation PV, under a 40% renewable portfolio standard in California. Thus, the high grid value of CSP-TES must be considered when evaluating renewable energy options. An assessmentmore » of net system cost accounts for the difference between the costs of adding new generation and the avoided cost from displacing other resources providing the same level of energy and reliability. The net system costs of several CSP configurations are compared with the net system costs of conventional natural-gas-fired combustion-turbine (CT) and combined-cycle plants. At today's low natural gas prices and carbon emission costs, the economics suggest a peaking configuration for CSP. However, with high natural gas prices and emission costs, each of the CSP configurations compares favorably against the conventional alternatives, and systems with intermediate to high capacity factors become the preferred alternatives. Another analysis compares net system costs for three configurations of CSP versus PV with batteries and PV with CTs. Under current technology costs, the least-expensive option is a combination of PV and CTs. However, under future cost assumptions, the optimal configuration of CSP becomes the most cost-effective option.« less

  3. REopt Lite Web Tool Evaluates Photovoltaics and Battery Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Building on the success of the REopt renewable energy integration and optimization platform, NREL has developed a free, publicly available web version of REopt called REopt Lite. REopt Lite evaluates the economics of grid-connected photovoltaics (PV) and battery storage at a site. It allows building owners to identify the system sizes and battery dispatch strategy that minimize their life cycle cost of energy. This web tool also estimates the amount of time a PV and storage system can sustain the site's critical load during a grid outage.

  4. PVMirrors: Hybrid PV/CSP collectors that enable lower LCOEs

    NASA Astrophysics Data System (ADS)

    Fisher, Kate; Yu, Zhengshan Jason; Striling, Rob; Holman, Zachary

    2017-06-01

    The primary challenge with concentrating solar power (CSP) is that the conversion efficiency is low—and the cost high—compared to that of photovoltaics (PV), and the primary challenge with PV is that the energy generated cannot be stored cost effectively. We introduce a technology that hybridizes CSP and PV, resulting in power plants with high energy conversion efficiency and affordable storage. This is accomplished by replacing silvered troughs (or heliostat facets) with "PVMirrors" that and direct photons of each wavelength to the converter (PV or thermal) that may best use them. A PVMirror looks like a curved PV module that includes a spectrum-splitting dichroic mirror film; this film, which is the heart of the technology, transmits near-infrared light to the underlying silicon PV cells while reflecting both longer and shorter wavelengths to a thermal absorber tube. This paper investigates the optical performance of dichroic mirror film, the specularity of PVMirrors, and the anticipated levelized cost of energy (LCOE) from a PVMirror power plant. PVMirrors are found to decrease LCOE by more than 15% relative to CSP while retaining full dispatchability.

  5. Visualization of the Eastern Renewable Generation Integration Study: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gruchalla, Kenny; Novacheck, Joshua; Bloom, Aaron

    The Eastern Renewable Generation Integration Study (ERGIS), explores the operational impacts of the wide spread adoption of wind and solar photovoltaics (PV) resources in the U.S. Eastern Interconnection and Quebec Interconnection (collectively, EI). In order to understand some of the economic and reliability challenges of managing hundreds of gigawatts of wind and PV generation, we developed state of the art tools, data, and models for simulating power system operations using hourly unit commitment and 5-minute economic dispatch over an entire year. Using NREL's high-performance computing capabilities and new methodologies to model operations, we found that the EI, as simulated withmore » evolutionary change in 2026, could balance the variability and uncertainty of wind and PV at a 5-minute level under a variety of conditions. A large-scale display and a combination of multiple coordinated views and small multiples were used to visually analyze the four large highly multivariate scenarios with high spatial and temporal resolutions. state of the art tools, data, and models for simulating power system operations using hourly unit commitment and 5-minute economic dispatch over an entire year. Using NRELs high-performance computing capabilities and new methodologies to model operations, we found that the EI, as simulated with evolutionary change in 2026, could balance the variability and uncertainty of wind and PV at a 5-minute level under a variety of conditions. A large-scale display and a combination of multiple coordinated views and small multiples were used to visually analyze the four large highly multivariate scenarios with high spatial and temporal resolutions.« less

  6. Development and design of photovoltaic power prediction system

    NASA Astrophysics Data System (ADS)

    Wang, Zhijia; Zhou, Hai; Cheng, Xu

    2018-02-01

    In order to reduce the impact of power grid safety caused by volatility and randomness of the energy produced in photovoltaic power plants, this paper puts forward a construction scheme on photovoltaic power generation prediction system, introducing the technical requirements, system configuration and function of each module, and discussing the main technical features of the platform software development. The scheme has been applied in many PV power plants in the northwest of China. It shows that the system can produce reasonable prediction results, providing a right guidance for dispatching and efficient running for PV power plant.

  7. Stem Inc. SunShot Incubator Program Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butterfield, Karen

    In this Energy Storage Control Algorithms project, Stem sought to develop tools and control algorithms to increase the value and reduce balance-of-system and grid integration costs associated with adding distributed solar generation to the grid. These advances fell under the headings SolarScope and SolarController. Stem sought to create initial market traction with a fully commercialized product for the solar industry to size storage systems (SolarScope) as well as a solar intermittency-mitigation framework for utilities (SolarController) in the course of the project. The company sought to align strategic growth plans and enable the rollout of the products to broader audiences inmore » multiple geographic regions by leveraging the major solar companies in the national market as partners. Both final products were both intended to be commercialized. They are: SolarScope: Analysis tool to identify viable PV + storage projects and thereby expedite the sales and interconnection processes. SolarScope combines customer load data, PV production estimates, utility rate tariff, and simulated storage into a simple user interface for PV developers. Developers can easily identify viable solar + storage sites without the need for complex and time consuming, site-by-site spreadsheet modeling. SolarContoller: Tool to autonomously dispatch distributed storage in order to mitigate voltage fluctuation and reduce curtailment. SolarController co-optimizes, in real time, storage dispatch for circuit stability and curtailment reduction, enabling higher penetrations of PV. SolarController is automated, not requiring utility dispatch or management, as Stem hardware senses grid voltage, frequency, customer load, PV production, and power factor. In the end the two products met with different outcomes. SolarScope was tested by potential users, and continues to be used as a foundational platform for partnership with key solar industry partners. SolarController, on the other hand, was successful in lab testing but was not commercialized due to a lack of marketability and lack of interested customer base. Together the development of these two products marked a material step forward for Stem; and a new milestone along the pathway of integration for the solar and storage industries. SolarScope is leading to real, out-of-the-lab project development in storage + solar for the commercial customer sector. Meanwhile SolarController has opened the eyes of regulators and utility executives alike to the potential of distributed solar and by doing so, has moved the conversation forward for the integration of distributed energy resources more broadly on the grid.« less

  8. Concentrated solar power plants impact on PV penetration level and grid flexibility under Egyptian climate

    NASA Astrophysics Data System (ADS)

    Moukhtar, Ibrahim; Elbaset, Adel A.; El Dein, Adel Z.; Qudaih, Yaser; Mitani, Yasunori

    2018-05-01

    Photovoltaic (PV) system integration in the electric grid has been increasing over the past decades. However, the impact of PV penetration on the electric grid, especially during the periods of higher and lower generation for the solar system at the middle of the day and during cloudy weather or at night respectively, limit the high penetration of solar PV system. In this research, a Concentrated Solar Power (CSP) with Thermal Energy Storage (TES) has been aggregated with PV system in order to accommodate the required electrical power during the higher and lower solar energy at all timescales. This paper analyzes the impacts of CSP on the grid-connected PV considering high penetration of PV system, particularly when no energy storages in the form of batteries are used. Two cases have been studied, the first when only PV system is integrated into the electric grid and the second when two types of solar energy (PV and CSP) are integrated. The System Advisor Model (SAM) software is used to simulate the output power of renewable energy. Simulation results show that the performance of CSP has a great impact on the penetration level of PV system and on the flexibility of the electric grid. The overall grid flexibility increases due to the ability of CSP to store and dispatch the generated power. In addition, CSP/TES itself has inherent flexibility. Therefore, CSP reduces the minimum generation constraint of the conventional generators that allows more penetration of the PV system.

  9. Power management of remote microgrids considering battery lifetime

    NASA Astrophysics Data System (ADS)

    Chalise, Santosh

    Currently, 20% (1.3 billion) of the world's population still lacks access to electricity and many live in remote areas where connection to the grid is not economical or practical. Remote microgrids could be the solution to the problem because they are designed to provide power for small communities within clearly defined electrical boundaries. Reducing the cost of electricity for remote microgrids can help to increase access to electricity for populations in remote areas and developing countries. The integration of renewable energy and batteries in diesel based microgrids has shown to be effective in reducing fuel consumption. However, the operational cost remains high due to the low lifetime of batteries, which are heavily used to improve the system's efficiency. In microgrid operation, a battery can act as a source to augment the generator or a load to ensure full load operation. In addition, a battery increases the utilization of PV by storing extra energy. However, the battery has a limited energy throughput. Therefore, it is required to provide balance between fuel consumption and battery lifetime throughput in order to lower the cost of operation. This work presents a two-layer power management system for remote microgrids. First layer is day ahead scheduling, where power set points of dispatchable resources were calculated. Second layer is real time dispatch, where schedule set points from the first layer are accepted and resources are dispatched accordingly. A novel scheduling algorithm is proposed for a dispatch layer, which considers the battery lifetime in optimization and is expected to reduce the operational cost of the microgrid. This method is based on a goal programming approach which has the fuel and the battery wear cost as two objectives to achieve. The effectiveness of this method was evaluated through a simulation study of a PV-diesel hybrid microgrid using deterministic and stochastic approach of optimization.

  10. Residential Solar PV Systems in the Carolinas: Opportunities and Outcomes.

    PubMed

    Alqahtani, Bandar Jubran; Holt, Kyra Moore; Patiño-Echeverri, Dalia; Pratson, Lincoln

    2016-02-16

    This paper presents a first-order analysis of the feasibility and technical, environmental, and economic effects of large levels of solar photovoltaic (PV) penetration within the services areas of the Duke Energy Carolinas (DEC) and Duke Energy Progress (DEP). A PV production model based on household density and a gridded hourly global horizontal irradiance data set simulates hourly PV power output from roof-top installations, while a unit commitment and real-time economic dispatch (UC-ED) model simulates hourly system operations. We find that the large generating capacity of base-load nuclear power plants (NPPs) without ramping capability in the region limits PV integration levels to 5.3% (6510 MW) of 2015 generation. Enabling ramping capability for NPPs would raise the limit of PV penetration to near 9% of electricity generated. If the planned retirement of coal-fired power plants together with new installations and upgrades of natural gas and nuclear plants materialize in 2025, and if NPPs operate flexibly, then the share of coal-fired electricity will be reduced from 37% to 22%. A 9% penetration of electricity from PV would further reduce the share of coal-fired electricity by 4-6% resulting in a system-wide CO2 emissions rate of 0.33 to 0.40 tons/MWh and associated abatement costs of 225-415 (2015$ per ton).

  11. Optimizing Microgrid Architecture on Department of Defense Installations

    DTIC Science & Technology

    2014-09-01

    PPA power purchase agreement PV photovoltaic QDR Quadrennial Defense Review SNL Sandia National Laboratory SPIDERS Smart Power Infrastructure...a MILP that dispatches fuel-based generators with consideration to an ensemble of forecasted inputs from renewable power sources, subject to physical...wind power project costs by region: 2012 projects, from [30]. 6. Weather Forecasts Weather forecasts are often presented as a single prediction

  12. A peaking-regulation-balance-based method for wind & PV power integrated accommodation

    NASA Astrophysics Data System (ADS)

    Zhang, Jinfang; Li, Nan; Liu, Jun

    2018-02-01

    Rapid development of China’s new energy in current and future should be focused on cooperation of wind and PV power. Based on the analysis of system peaking balance, combined with the statistical features of wind and PV power output characteristics, a method of comprehensive integrated accommodation analysis of wind and PV power is put forward. By the electric power balance during night peaking load period in typical day, wind power installed capacity is determined firstly; then PV power installed capacity could be figured out by midday peak load hours, which effectively solves the problem of uncertainty when traditional method hard determines the combination of the wind and solar power simultaneously. The simulation results have validated the effectiveness of the proposed method.

  13. Policies to keep and expand the option of concentrating solar power for dispatchable renewable electricity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lilliestam, Johan; Barradi, Touria; Caldes, Natalia

    Concentrating solar power (CSP) is one of the few renewable electricity technologies that can offer dispatchable electricity at large scale. Thus, it may play an important role in the future, especially to balance fluctuating sources in increasingly renewables-based power systems. Today, its costs are higher than those of PV and wind power and, as most countries do not support CSP, deployment is slow. Unless the expansion gains pace and costs decrease, the industry may stagnate or collapse, and an important technology for climate change mitigation has been lost. Keeping CSP as a maturing technology for dispatchable renewable power thus requiresmore » measures to improve its short-term economic attractiveness and to continue reducing costs in the longer term. We suggest a set of three policy instruments - feed-in tariffs or auctions reflecting the value of dispatchable CSP, and not merely its cost; risk coverage support for innovative designs; and demonstration projects - to be deployed, in regions where CSP has a potentially large role to play. This could provide the CSP industry with a balance of attractive profits and competitive pressure, the incentive to expand CSP while also reducing its costs, making it ready for broad-scale deployment when it is needed.« less

  14. Policies to keep and expand the option of concentrating solar power for dispatchable renewable electricity

    DOE PAGES

    Lilliestam, Johan; Barradi, Touria; Caldes, Natalia; ...

    2018-02-16

    Concentrating solar power (CSP) is one of the few renewable electricity technologies that can offer dispatchable electricity at large scale. Thus, it may play an important role in the future, especially to balance fluctuating sources in increasingly renewables-based power systems. Today, its costs are higher than those of PV and wind power and, as most countries do not support CSP, deployment is slow. Unless the expansion gains pace and costs decrease, the industry may stagnate or collapse, and an important technology for climate change mitigation has been lost. Keeping CSP as a maturing technology for dispatchable renewable power thus requiresmore » measures to improve its short-term economic attractiveness and to continue reducing costs in the longer term. We suggest a set of three policy instruments - feed-in tariffs or auctions reflecting the value of dispatchable CSP, and not merely its cost; risk coverage support for innovative designs; and demonstration projects - to be deployed, in regions where CSP has a potentially large role to play. This could provide the CSP industry with a balance of attractive profits and competitive pressure, the incentive to expand CSP while also reducing its costs, making it ready for broad-scale deployment when it is needed.« less

  15. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant.

    PubMed

    Moreno-Garcia, Isabel M; Palacios-Garcia, Emilio J; Pallares-Lopez, Victor; Santiago, Isabel; Gonzalez-Redondo, Miguel J; Varo-Martinez, Marta; Real-Calvo, Rafael J

    2016-05-26

    There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV) energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant's components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid.

  16. An Overview of the Automated Dispatch Controller Algorithms in the System Advisor Model (SAM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiOrio, Nicholas A

    2017-11-22

    Three automatic dispatch modes have been added to the battery model within the System Adviser Model. These controllers have been developed to perform peak shaving in an automated fashion, providing users with a way to see the benefit of reduced demand charges without manually programming a complicated dispatch control. A flexible input option allows more advanced interaction with the automated controller. This document will describe the algorithms in detail and present brief results on its use and limitations.

  17. The Potential for Energy Storage to Provide Peaking Capacity in California Under Increased Penetration of Solar Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul L; Margolis, Robert M

    In this report, we examine the potential for replacing conventional peaking capacity in California with energy storage, including analysis of the changing technical potential with increased storage deployment and the effect of PV deployment. We examine nine years of historic load data, a range of storage durations (2-8 hours), and a range of PV penetration levels (0%-30%). We demonstrate how PV increases the ability of storage to reduce peak net demand. In the scenarios analyzed, the expected penetration of PV in California in 2020 could more than double the potential for 4-hour energy storage to provide capacity services.

  18. Consumption Behavior Analytics-Aided Energy Forecasting and Dispatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yingchen; Yang, Rui; Jiang, Huaiguang

    For decades, electricity customers have been treated as mere recipients of electricity in vertically integrated power systems. However, as customers have widely adopted distributed energy resources and other forms of customer participation in active dispatch (such as demand response) have taken shape, the value of mining knowledge from customer behavior patterns and using it for power system operation is increasing. Further, the variability of renewable energy resources has been considered a liability to the grid. However, electricity consumption has shown the same level of variability and uncertainty, and this is sometimes overlooked. This article investigates data analytics and forecasting methodsmore » to identify correlations between electricity consumption behavior and distributed photovoltaic (PV) output. The forecasting results feed into a predictive energy management system that optimizes energy consumption in the near future to balance customer demand and power system needs.« less

  19. Real-Time Monitoring System for a Utility-Scale Photovoltaic Power Plant

    PubMed Central

    Moreno-Garcia, Isabel M.; Palacios-Garcia, Emilio J.; Pallares-Lopez, Victor; Santiago, Isabel; Gonzalez-Redondo, Miguel J.; Varo-Martinez, Marta; Real-Calvo, Rafael J.

    2016-01-01

    There is, at present, considerable interest in the storage and dispatchability of photovoltaic (PV) energy, together with the need to manage power flows in real-time. This paper presents a new system, PV-on time, which has been developed to supervise the operating mode of a Grid-Connected Utility-Scale PV Power Plant in order to ensure the reliability and continuity of its supply. This system presents an architecture of acquisition devices, including wireless sensors distributed around the plant, which measure the required information. It is also equipped with a high-precision protocol for synchronizing all data acquisition equipment, something that is necessary for correctly establishing relationships among events in the plant. Moreover, a system for monitoring and supervising all of the distributed devices, as well as for the real-time treatment of all the registered information, is presented. Performances were analyzed in a 400 kW transformation center belonging to a 6.1 MW Utility-Scale PV Power Plant. In addition to monitoring the performance of all of the PV plant’s components and detecting any failures or deviations in production, this system enables users to control the power quality of the signal injected and the influence of the installation on the distribution grid. PMID:27240365

  20. Spectrum-splitting hybrid CSP-CPV solar energy system with standalone and parabolic trough plant retrofit applications

    NASA Astrophysics Data System (ADS)

    Orosz, Matthew; Zweibaum, Nicolas; Lance, Tamir; Ruiz, Maritza; Morad, Ratson

    2016-05-01

    Sunlight to electricity efficiencies of Parabolic Trough Collector (PTC) plants are typically on the order of 15%, while commercial solar Photovoltaic (PV) technologies routinely achieve efficiencies of greater than 20%, albeit with much higher conversion efficiencies of photons at the band gap. Hybridizing concentrating solar power and photovoltaic technologies can lead to higher aggregate efficiencies due to the matching of photons to the appropriate converter based on wavelength. This can be accomplished through spectral filtering whereby photons unusable or poorly utilitized by PV (IR and UV) are passed through to a heat collection element, while useful photons (VIS) are reflected onto a concentrating PV (CPV) receiver. The mechanical design and experimental validation of spectral splitting optics is described in conjunction with system level modeling and economic analysis. The implications of this architecture include higher efficiency, lower cost hybrid CSP-PV power systems, as well as the potential to retrofit existing PTC plants to boost their output by ~ 10% at a projected investment cost of less than 1 per additional net Watt and an IRR of 18%, while preserving the dispatchability of the CSP plant's thermal energy storage.

  1. Dispatch Strategy Development for Grid-tied Household Energy Systems

    NASA Astrophysics Data System (ADS)

    Cardwell, Joseph

    The prevalence of renewable generation will increase in the next several decades and offset conventional generation more and more. Yet this increase is not coming without challenges. Solar, wind, and even some water resources are intermittent and unpredictable, and thereby create scheduling challenges due to their inherent "uncontrolled" nature. To effectively manage these distributed renewable assets, new control algorithms must be developed for applications including energy management, bridge power, and system stability. This can be completed through a centralized control center though efforts are being made to parallel the control architecture with the organization of the renewable assets themselves--namely, distributed controls. Building energy management systems are being employed to control localized energy generation, storage, and use to reduce disruption on the net utility load. One such example is VOLTTRONTM, an agent-based platform for building energy control in real time. In this thesis, algorithms developed in VOLTTRON simulate a home energy management system that consists of a solar PV array, a lithium-ion battery bank, and the grid. Dispatch strategies are implemented to reduce energy charges from overall consumption (/kWh) and demand charges (/kW). Dispatch strategies for implementing storage devices are tuned on a month-to-month basis to provide a meaningful economic advantage under simulated scenarios to explore algorithm sensitivity to changing external factors. VOLTTRON agents provide automated real-time optimization of dispatch strategies to efficiently manage energy supply and demand, lower consumer costs associated with energy usage, and reduce load on the utility grid.

  2. The influence of emotional stress on Doppler-derived aortic peak velocity in boxer dogs.

    PubMed

    Pradelli, D; Quintavalla, C; Crosta, M C; Mazzoni, L; Oliveira, P; Scotti, L; Brambilla, P; Bussadori, C

    2014-01-01

    Subaortic stenosis (SAS) is a common congenital heart disease in Boxers. Doppler-derived aortic peak velocity (AoPV) is a diagnostic criterion for the disease. To investigate the influence of emotional stress during echocardiographic examination on AoPV in normal and SAS-affected Boxers. To evaluate the effects of aortic root diameters on AoPV in normal Boxers. DOGS: Two hundred and fifteen normal and 19 SAS-affected Boxers. The AoPV was recorded at the beginning of echocardiographic examination (T0), and when the emotional stress of the dog was assumed to decrease based on behavioral parameters and heart rate (T1). AoPV0-AoPV1 was calculated. In normal dogs, stroke volume index was calculated at T0 and T1. Aortic root diameters were measured and their relationship with AoPV and AoPV0-AoPV1 was evaluated. In normal dogs, AoPV was higher at T0 (median, 1.95 m/s; range, 1.60-2.50 m/s) than at T1 (median, 1.76 m/s; range, 1.40-2.20 m/s; P < .0001; reduction 9.2%). The stroke volume index at T0 also was greater than at T1 (P < .0001). Weak negative correlations were detected between aortic root size and aortic velocities. In SAS-affected dogs, AoPV0 was higher than AoPV1 (P < .0001; reduction 7.3%). Aortic peak velocity was affected by emotional stress during echocardiographic examination both in SAS-affected and normal Boxers. In normal Boxers, aortic root size weakly affected AoPVs, but did not affect AoPV0-AoPV1. Stroke volume seems to play a major role in stress-related AoPV increases in normal Boxers. Emotional stress should be taken into account when screening for SAS in the Boxer breed. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  3. Direct detection of the plant pathogens Burkholderia glumae, Burkholderia gladioli pv. gladioli, and Erwinia chrysanthemi pv. zeae in infected rice seedlings using matrix assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Kajiwara, Hideyuki

    2016-01-01

    The plant pathogens Burkholderia glumae, Burkholderia gladioli pv. gladioli, and Erwinia chrysanthemi pv. zeae were directly detected in extracts from infected rice seedlings by matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This method did not require culturing of the pathogens on artificial medium. In the MALDI-TOF MS analysis, peaks originating from bacteria were found in extracts from infected rice seedlings. The spectral peaks showed significantly high scores, in spite of minor differences in spectra. The spectral peaks originating from host plant tissues did not affect this direct MALDI-TOF MS analysis for the rapid identification of plant pathogens. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Dispatchable hydrogen production at the forecourt for electricity grid balancing

    NASA Astrophysics Data System (ADS)

    Rahil, Abdulla; Gammon, Rupert; Brown, Neil

    2017-02-01

    The rapid growth of renewable energy (RE) generation and its integration into electricity grids has been motivated by environmental issues and the depletion of fossil fuels. For the same reasons, an alternative to hydrocarbon fuels is needed for vehicles; hence the anticipated uptake of electric and fuel cell vehicles. High penetrations of RE generators with variable and intermittent output threaten to destabilise electricity networks by reducing the ability to balance electricity supply and demand. This can be greatly mitigated by the use of energy storage and demand-side response (DSR) techniques. Hydrogen production by electrolysis is a promising option for providing DSR as well as an emission-free vehicle fuel. Tariff structures can be used to incentivise the operating of electrolysers as controllable (dispatchable) loads. This paper compares the cost of hydrogen production by electrolysis at garage forecourts under both dispatchable and continuous operation, while ensuring no interruption of fuel supply to fuel cell vehicles. An optimisation algorithm is applied to investigate a hydrogen refueling station in both dispatchable and continuous operation. Three scenarios are tested to see whether a reduced off-peak electricity price could lower the cost of electrolytic hydrogen. These scenarios are: 1) "Standard Continuous", where the electrolyser is operated continuously on a standard all-day tariff of 12p/kWh; 2) "Off-peak Only", where it runs only during off-peak periods in a 2-tier tariff system at the lower price of 5p/kWh; and 3) "2-Tier Continuous", operating continuously and paying a low tariff at off- peak times and a high tariff at other times. This study uses the Libyan coastal city of Derna as a case study. The cheapest electricity cost per kg of hydrogen produced was £2.8, which occurred in Scenario 2. The next cheapest, at £5.8 - £6.3, was in Scenario 3, and the most expensive was £6.8/kg in Scenario 1.

  5. New Analysis Finds Synergistic Relationship Between High PV Penetration and

    Science.gov Websites

    High PV Penetration and Energy Storage Deployment April 10, 2018 Adding higher penetrations of solar High PV Penetration and Energy Storage Deployment New Analysis Finds Synergistic Relationship Between photovoltaics (PV) to the electric power grid could increase the potential for energy storage to meet peak

  6. Effect of Pharmacologically-Induced Hypovolemia on Aerobic Capacity

    NASA Technical Reports Server (NTRS)

    Everett, Meghan E.; Lee, S. M. C.; Platts, S. H.

    2009-01-01

    Decreased peak oxygen consumption (VO2pk) and an elevated exercise heart rate (HR) response are associated with a reduction in plasma volume (PV) after space flight and bed rest, a space flight analog. Reduced VO2pk and submaximal exercise tolerance would negatively impact an astronaut s ability to perform near maximal work that would be required in the event of an emergency. We previously have administered IV furosemide followed by a low salt diet to model PV loss and orthostatic intolerance observed after spaceflight. Purpose: To determine whether a pharmacologically-induced reduction in PV results in decreased VO2pk and elevated exercise HR response. Methods: Six subjects (5M, 1F) performed two graded peak cycle tests (work rate increased by 35 or 50 W every 3 min), once while normovolemic and once while hypovolemic. HR and expired respiratory gases were continuously measured. To induce hypovolemia, subjects were administered a single dose of IV furosemide (0.5 mg.kg-1) 30 hr before exercise testing and then consumed a low-salt diet (10 mEq.d(sup -1)). PV was measured using carbon monoxide rebreathing. Exercise HR and VO2 responses were quantified as the area under the curve (AUC) calculated over each quartile of the peak test, based on test time in the hypovolemia condition. Paired t-tests were used to test for differences in PV, VO2pk, and peak HR between conditions. Repeated-measures ANOVAs were used to test for differences in AUC between conditions. Results: PV (3.32+/-0.12 vs. 2.77+/-0.16 L, p<0.05) and VO2pk (3.30+/-0.67 vs. 2.90+/-0.57 L.min(sup -1), p<0.05) were lower during hypovolemia than during normovolemia, but peak HR was not different (187+/-5 vs. 187+/-5 bpm). The AUC for VO2 and HR was different (p<0.05) between conditions only in the highest quartile: HR was 4% higher and VO2 was 5% lower during the hypovolemia condition. Conclusion: The mean difference in VO2pk (-12%) between normovolemia and hypovolemia was similar to the mean difference in PV (-17%). Similar decreases in PV and VO2pk have been observed following short duration space flight, suggesting that pharmacologically-induced PV loss can be used to model microgravity-induced reductions in VO2pk.

  7. Limits and Economic Effects of Distributed PV Generation in North and South Carolina

    NASA Astrophysics Data System (ADS)

    Holt, Kyra Moore

    The variability of renewable sources, such as wind and solar, when integrated into the electrical system must be compensated by traditional generation sources in-order to maintain the constant balance of supply and demand required for grid stability. The goal of this study is to analyze the effects of increasing large levels of solar Photovoltaic (PV) penetration (in terms of a percentage of annual energy production) on a test grid with similar characteristics to the Duke Energy Carolinas (DEC) and Progress Energy Carolinas (PEC) regions of North and South Carolina. PV production is modeled entering the system at the distribution level and regional PV capacity is based on household density. A gridded hourly global horizontal irradiance (GHI) dataset is used to capture the variable nature of PV generation. A unit commitment model (UCM) is then used determine the hourly dispatch of generators based on generator parameters and costs to supply generation to meet demand. Annual modeled results for six different scenarios are evaluated to determine technical, environmental and economic effects of varying levels of distributed PV penetration on the system. This study finds that the main limiting factor for PV integration in the DEC and PEC balancing authority regions is defined by the large generating capacity of base-load nuclear plants within the system. This threshold starts to affect system stability at integration levels of 5.7%. System errors, defined by imbalances caused by over or under generation with respect to demand, are identified in the model however the validity of these errors in real world context needs further examination due to the lack of high frequency irradiance data and modeling limitations. Operational system costs decreased as expected with PV integration although further research is needed to explore the impacts of the capital costs required to achieve the penetration levels found in this study. PV system generation was found to mainly displace coal generation creating a loss of revenue for generator owners. In all scenarios, CO 2 emissions were reduced with PV integration. This reduction could be used to meet impending EPA state-specific CO2 emissions targets.

  8. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed studymore » could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.« less

  9. Anti-islanding protection using a twin-peak band-pass filter in interconnected PV systems, and substantiating evaluations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishida, T.; Hagihara, R.; Yugo, M.

    1994-12-31

    The authors have successfully developed and industrialized a new frequency-shift anti-islanding protection method using a twin-peak band-pass filter (BPF) for grid-interconnected photovoltaic (PV) systems. In this method, the power conditioner has a twin-peak BPF in a current feed back loop in place of the normal BPF. The new method works perfectly for various kinds of loads such as resistance, inductive and capacitive loads connected to the PV system. Furthermore, because there are no mis-detections, the system enables the most effective generation of electric energy from solar cells. A power conditioner equipped with this protection was officially certified as suitable formore » grid-interconnection.« less

  10. Hybrid solar collector using nonimaging optics and photovoltaic components

    NASA Astrophysics Data System (ADS)

    Winston, Roland; Yablonovitch, Eli; Jiang, Lun; Widyolar, Bennett K.; Abdelhamid, Mahmoud; Scranton, Gregg; Cygan, David; Kozlov, Alexandr

    2015-08-01

    The project team of University of California at Merced (UC-M), Gas Technology Institute, and Dr. Eli Yablonovitch of University of California at Berkeley developed a novel hybrid concentrated solar photovoltaic thermal (PV/T) collector using nonimaging optics and world record single-junction Gallium arsenide (GaAs) PV components integrated with particle laden gas as thermal transfer and storage media, to simultaneously generate electricity and high temperature dispatchable heat. The collector transforms a parabolic trough, commonly used in CSP plants, into an integrated spectrum-splitting device. This places a spectrum-sensitive topping element on a secondary reflector that is registered to the thermal collection loop. The secondary reflector transmits higher energy photons for PV topping while diverting the remaining lower energy photons to the thermal media, achieving temperatures of around 400°C even under partial utilization of the solar spectrum. The collector uses the spectral selectivity property of Gallium arsenide (GaAs) cells to maximize the exergy output of the system, resulting in an estimated exergy efficiency of 48%. The thermal media is composed of fine particles of high melting point material in an inert gas that increases heat transfer and effectively stores excess heat in hot particles for later on-demand use.

  11. Solar + Storage Synergies for Managing Commercial-Customer Demand Charges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gagnon, P.; Govindarajan, A.; Bird, L.

    Demand charges, which are based on a customer’s maximum demand in kilowatts (kW), are a common element of electricity rate structures for commercial customers. Customer-sited solar photovoltaic (PV) systems can potentially reduce demand charges, but the level of savings is difficult to predict, given variations in demand charge designs, customer loads, and PV generation profiles. Lawrence Berkeley National Laboratory (Berkeley Lab) and the National Renewable Energy Laboratory (NREL) are collaborating on a series of studies to understand how solar PV can impact demand charges. Prior studies in the series examined demand charge reductions from solar on a stand-alone basis formore » residential and commercial customers. Those earlier analyses found that solar, alone, has limited ability to reduce demand charges depending on the specific design of the demand charge and on the shape of the customer’s load profile. This latest analysis estimates demand charge savings from solar in commercial buildings when co-deployed with behind-the-meter storage, highlighting the complementary roles of the two technologies. The analysis is based on simulated loads, solar generation, and storage dispatch across a wide variety of building types, locations, system configurations, and demand charge designs.« less

  12. Improving Photovoltaic Energy Production with Fiber-Optic Distributed Temperature Sensing

    NASA Astrophysics Data System (ADS)

    Hausner, M. B.; Berli, M.

    2014-12-01

    The efficiency of solar photovoltaic (PV) generators declines sharply with increased temperatures. Peak solar exposure often occurs at the same time as peak temperatures, but solar PV installations are typically designed based on solar angle. In temperate areas, the peak temperatures may not be high enough to induce significant efficiency losses. In some of the areas with the greatest potential for solar development, however, summer air temperatures regularly reach 45 °C and PV panel temperatures exceed the air temperatures. Here we present a preliminary model of a PV array intended to optimize solar production in a hot and arid environment. The model begins with the diurnal and seasonal cycles in the angle and elevation of the sun, but also includes a meteorology-driven energy balance to project the temperatures of the PV panels and supporting structure. The model will be calibrated and parameterized using a solar array at the Desert Research Institute's (DRI) Renewable Energy Deployment and Display (REDD) facility in Reno, Nevada, and validated with a similar array at DRI's Las Vegas campus. Optical fibers will be installed on the PV panels and structural supports and interrogated by a distributed temperature sensor (DTS) to record the spatial and temporal variations in temperature. Combining the simulated panel temperatures, the efficiency-temperature relationship for the panels, and the known solar cycles at a site will allow us to optimize the design of future PV collectors (i.e., the aspect and angle of panels) for given production goals.

  13. Economically dispatching cogeneration facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, E.

    Economic dispatching has been used by utilities to meet the energy demands of their customers for decades. The objective was to first load those units which cost the least to run and slowly increase the loading of more expensive units as the incremental energy price increased. Although this concept worked well for utility based systems where incremental costs rose with peak demand, the independent power producers(IPPs) and the power purchase agreements (PPAs) have drastically changed this notion. Most PPAs structured for the IPP environment have negotiated rates which remain the same during peak periods and base their electrical generation onmore » specific process steam requirements. They also must maintain the required production balance of process steam and electrical load in order to qualify as a Public Utility Regulatory Policies Act (PURPA) facility. Consequently, economically dispatching Cogeneration facilities becomes an exercise in adhering to contractual guidelines while operating the equipment in the most efficient manner possible for the given condition. How then is it possible to dispatch a Cogeneration facility that maintains the electrical load demand of JFK Airport while satisfying all of its heating and cooling needs? Contractually, Kennedy International Airport Cogen (KIAC) has specific obligations concerning electrical and thermal energy exported to JFK Airport. The facility`s impressive array of heating and cooling apparatuses together with the newly installed cogen fulfilled the airport`s needs by utilizing an endless combination of new and previously installed equipment. Moreover, in order to economically operate the plant a well structured operating curriculum was necessary.« less

  14. Photovoltaic electricity generation: Value for residential and commercial sectors

    NASA Astrophysics Data System (ADS)

    Bhattacharjee, Ujjwal

    The photovoltaic (PV) industry in the US has seen an upsurge in recent years, and PV holds great promise as a renewable technology with no greenhouse gas emissions with its use. We aim to assess the value of PV based electricity for users in the residential and commercial sectors focusing on the financial impacts it has, which may not be greatly recognized. Specifically, we pursue two goals. First, the emerging 'renewable portfolio standard (RPS)' adopted in several states in the country has been a driving force for large scale PV deployment, but financial incentives offered to PV in different RPS states differ considerably. We use life cycle cost model to estimate the cost of PV based electricity for thirty-two RPS states in the country. Results indicate that the levelized cost of PV electricity is high (40 to 60 Cents/kWh). When the contribution of the financial incentives (along with the cost of energy saved) is taken into account, the cost of PV based electricity is negative in some RPS states such as California, New Jersey, New York, while for most of the RPS states the cost of PV electricity continues to remain high. In addition, the states with negative or low cost of PV electricity have been driving the PV diffusion in the residential sector. Therefore, a need to adjust the financial incentive structure in different RPS states is recommended for homogenous development of the residential PV market in the country. Second, we assess the value of the PV in reducing the highest peak load demand in commercial buildings and hence the high value demand charge. The Time-of-Use (TOU) based electricity tariff is widely used by electric utilities in the commercial sector. Energy and peak load are two important facets of the TOU tariff regime. Tools are well established to estimate the energy contribution from a PV system (installed in a commercial building), but not power output on a short time interval. A joint conditional probability model has been developed that enables estimation of the PV contribution towards the peak load reduction for a given high building load. Results indicate a significant cost saving (15% to 40%) with application of the model. This will encourage commercial entities (building owners) to adopt PV as a distributed energy source. The tool would be useful for energy modelers and green building architects as it will enable them to estimate cost savings due to PV deployment in commercial buildings. Moreover, the model tested for three different commercial buildings indicates that school buildings show the best promise for PV deployment followed, respectively, by office buildings and manufacturing facilities. This will help PV incentive programs in the country to use resources effectively to enhance the diffusion of PV in the commercial sector.

  15. PV FAQs: Does the world have enough materials for PV to help address climate change?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2005-06-01

    In the ongoing discussion of what needs to be done to stabilize atmospheric CO2 by mid-century (Hoffert 1998), one possible option would be to add about 10-20 terawatts (trillion watts, or TW) of photovoltaics (PV) in place of conventional sources. PV would help because, unlike burning fossil fuels, it produces no CO2. However, 10-20 TW is an enormous amount of energy. In peak Watts, the way PV installations are generally rated, it is about 50-100 TWpeak (TWp) of PV. Would we have enough materials to make this much PV? As we explain in this PV FAQ, we think our planetmore » has enough feedstock materials for PV to meet the ''TW challenge.''« less

  16. The capacity credit of grid-connected photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Alsema, E. A.; van Wijk, A. J. M.; Turkenburg, W. C.

    The capacity credit due photovoltaic (PV) power plants if integrated into the Netherlands grid was investigated, together with an estimate of the total allowable penetration. An hourly simulation was performed based on meteorological data from five stations and considering tilted surfaces, the current grid load pattern, and the load pattern after PV-power augmentation. The reliability of the grid was assessed in terms of a loss of load probability analysis, assuming power drops were limited to 1 GW. A projected tolerance for 2.5 GW of PV power was calculated. Peak demands were determined to be highest in winter, contrary to highest insolation levels; however, daily insolation levels coincided with daily peak demands. Combining the PV input with an equal amount of wind turbine power production was found to augment the capacity credit for both at aggregate outputs of 2-4 GW.

  17. Energy efficiency design strategies for buildings with grid-connected photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Yimprayoon, Chanikarn

    The building sector in the United States represents more than 40% of the nation's energy consumption. Energy efficiency design strategies and renewable energy are keys to reduce building energy demand. Grid-connected photovoltaic (PV) systems installed on buildings have been the fastest growing market in the PV industry. This growth poses challenges for buildings qualified to serve in this market sector. Electricity produced from solar energy is intermittent. Matching building electricity demand with PV output can increase PV system efficiency. Through experimental methods and case studies, computer simulations were used to investigate the priorities of energy efficiency design strategies that decreased electricity demand while producing load profiles matching with unique output profiles from PV. Three building types (residential, commercial, and industrial) of varying sizes and use patterns located in 16 climate zones were modeled according to ASHRAE 90.1 requirements. Buildings were analyzed individually and as a group. Complying with ASHRAE energy standards can reduce annual electricity consumption at least 13%. With energy efficiency design strategies, the reduction could reach up to 65%, making it possible for PV systems to meet reduced demands in residential and industrial buildings. The peak electricity demand reduction could be up to 71% with integration of strategies and PV. Reducing lighting power density was the best single strategy with high overall performances. Combined strategies such as zero energy building are also recommended. Electricity consumption reductions are the sum of the reductions from strategies and PV output. However, peak electricity reductions were less than their sum because they reduced peak at different times. The potential of grid stress reduction is significant. Investment incentives from government and utilities are necessary. The PV system sizes on net metering interconnection should not be limited by legislation existing in some states. Data from this study provides insight of impacts from applying energy efficiency design strategies in buildings with grid-connected PV systems. With the current transition from traditional electric grids to future smart grids, this information plus large database of various building conditions allow possible investigations needed by governments or utilities in large scale communities for implementing various measures and policies.

  18. Plasma volume shifts with immersion at rest and two exercise intensities.

    PubMed

    Ertl, A C; Bernauer, E M; Hom, C A

    1991-04-01

    Eight men were studied to determine the effect of cycling exercise on plasma volume (PV) during water immersion to the xiphoid process (WIX). In all protocols the subjects were seated upright. After 30 min of rest, subjects were immersed in 34.5 degrees C water and seated on a cycling ergometer. During three 1 h WIX protocols, subjects either remained at rest (No Ex) or pedaled from minutes 20 to 30 at 38% (Ex1) or 62% (Ex2) of peak oxygen consumption (VO2peak). Hematocrit (Hct) and hemoglobin concentration [( Hb]) from venous blood samples were compared pre-WIX and at minutes 20, 30, 40, and 60. Percent change in PV (delta PV) was calculated from pre-WIX Hct and [Hb] within each protocol. Hct and [Hb] decreased after 20 min of resting WIX (P less than 0.017). In the No Ex protocol, there were no further significant changes in these variables, with delta PV values of +10.4% at minute 20 and at a peak of +13.5% at minute 40. In Ex1 and Ex2, cycling increased Hct and [Hb] (P less than 0.01, minute 30 vs No Ex), with delta PV values at minute 30 of +3.7% and -0.9%, respectively, vs +12.8% in No Ex. Minute 60 values between protocols were not significantly different (mean delta PV of +10.8 +/- 0.6% SD). The hemodilution associated with WIX was either partially or completely attenuated by cycling exercise; the degree of hemoconcentration was related to exercise intensity. The exercise-induced hemoconcentration was reversed by 30 min of resting WIX. Exercise during WIX appears to cause similar decreases in PV, as does exercise in air provided that postural hemoconcentration prior to exercise is not already maximal.

  19. Decentralized Optimal Dispatch of Photovoltaic Inverters in Residential Distribution Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dall'Anese, Emiliano; Dhople, Sairaj V.; Johnson, Brian B.

    Summary form only given. Decentralized methods for computing optimal real and reactive power setpoints for residential photovoltaic (PV) inverters are developed in this paper. It is known that conventional PV inverter controllers, which are designed to extract maximum power at unity power factor, cannot address secondary performance objectives such as voltage regulation and network loss minimization. Optimal power flow techniques can be utilized to select which inverters will provide ancillary services, and to compute their optimal real and reactive power setpoints according to well-defined performance criteria and economic objectives. Leveraging advances in sparsity-promoting regularization techniques and semidefinite relaxation, this papermore » shows how such problems can be solved with reduced computational burden and optimality guarantees. To enable large-scale implementation, a novel algorithmic framework is introduced - based on the so-called alternating direction method of multipliers - by which optimal power flow-type problems in this setting can be systematically decomposed into sub-problems that can be solved in a decentralized fashion by the utility and customer-owned PV systems with limited exchanges of information. Since the computational burden is shared among multiple devices and the requirement of all-to-all communication can be circumvented, the proposed optimization approach scales favorably to large distribution networks.« less

  20. Temporal and spatial variation of heat-related illness using 911 medical dispatch data.

    PubMed

    Bassil, Kate L; Cole, Donald C; Moineddin, Rahim; Craig, Alan M; Lou, W Y Wendy; Schwartz, Brian; Rea, Elizabeth

    2009-07-01

    The adverse effect of hot weather on health in urban communities is of increasing public health concern, particularly given trends in climate change. To demonstrate the potential public health applications of monitoring 911 medical dispatch data for heat-related illness (HRI), using historical data for the summer periods (June 1-August 31) during 2002-2005 in Toronto, Ontario, Canada. The temporal distribution of the medical dispatch calls was described in relation to a current early warning system and emergency department data from the National Ambulatory Care Reporting System (NACRS). Geospatial methods were used to map the percentage of heat-related calls in each Toronto neighborhood over the study period. The temporal pattern of 911 calls for HRI was similar, and sometimes peaked earlier, than current heat health warning systems (HHWS). The pattern of calls was similar to NACRS HRI visits, with the exception of 2005 where 911 calls peaked earlier. Areas of the city with a relatively higher burden of HRI included low income inner-city neighborhoods, areas with high rates of street-involved individuals, and areas along the waterfront which include summer outdoor recreational activities. Identifying the temporal trends and geospatial patterns of these important environmental health events has the potential to direct targeted public health interventions to mitigate associated morbidity and mortality.

  1. High P/V ratio of GaInAs/InP resonant tunneling diode grown by OMVPE

    NASA Astrophysics Data System (ADS)

    Sekiguchi, Tomonori; Miyamoto, Yasuyuki; Furuya, Kazuhito

    1992-11-01

    This paper reports higher peak-to-valley current (P/V) ratio in GaInAs/InP resonant tunneling diode (RTD) than ever. In organomettalic vapor phase epitaxy, the P/V ratio depends strongly on the partial pressure of the group V gas. The obtained P/V ratios are 9.7 and 7.4 at 4 and 77 K, respectively. The width of the resonance level is 11 meV at 4 K.

  2. Performance modeling and techno-economic analysis of a modular concentrated solar power tower with latent heat storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rea, Jonathan E.; Oshman, Christopher J.; Olsen, Michele L.

    In this paper, we present performance simulations and techno-economic analysis of a modular dispatchable solar power tower. Using a heliostat field and power block three orders of magnitude smaller than conventional solar power towers, our unique configuration locates thermal storage and a power block directly on a tower receiver. To make the system dispatchable, a valved thermosyphon controls heat flow from a latent heat thermal storage tank to a Stirling engine. The modular design results in minimal balance of system costs and enables high deployment rates with a rapid realization of economies of scale. In this new analysis, we combinemore » performance simulations with techno-economic analysis to evaluate levelized cost of electricity, and find that the system has potential for cost-competitiveness with natural gas peaking plants and alternative dispatchable renewables.« less

  3. The Effect of Metal-Semiconductor Contact on the Transient Photovoltaic Characteristic of HgCdTe PV Detector

    PubMed Central

    Cui, Haoyang; Xu, Yongpeng; Yang, Junjie; Tang, Naiyun; Tang, Zhong

    2013-01-01

    The transient photovoltaic (PV) characteristic of HgCdTe PV array is studied using an ultrafast laser. The photoresponse shows an apparent negative valley first, then it evolves into a positive peak. By employing a combined theoretical model of pn junction and Schottky potential, this photo-response polarity changing curves can be interpreted well. An obvious decreasing of ratio of negative valley to positive peak can be realized by limiting the illumination area of the array electrode. This shows that the photoelectric effect of Schottky barrier at metal-semiconductor (M/S) interface is suppressed, which will verify the correctness of the model. The characteristic parameters of transient photo-response induced from p-n junction and Schottky potential are extracted by fitting the response curve utilizing this model. It shows that the negative PV response induced by the Schottky barrier decreases the positive photovoltage generated by the pn junction. PMID:24194676

  4. The effect of metal-semiconductor contact on the transient photovoltaic characteristic of HgCdTe PV detector.

    PubMed

    Cui, Haoyang; Xu, Yongpeng; Yang, Junjie; Tang, Naiyun; Tang, Zhong

    2013-01-01

    The transient photovoltaic (PV) characteristic of HgCdTe PV array is studied using an ultrafast laser. The photoresponse shows an apparent negative valley first, then it evolves into a positive peak. By employing a combined theoretical model of pn junction and Schottky potential, this photo-response polarity changing curves can be interpreted well. An obvious decreasing of ratio of negative valley to positive peak can be realized by limiting the illumination area of the array electrode. This shows that the photoelectric effect of Schottky barrier at metal-semiconductor (M/S) interface is suppressed, which will verify the correctness of the model. The characteristic parameters of transient photo-response induced from p-n junction and Schottky potential are extracted by fitting the response curve utilizing this model. It shows that the negative PV response induced by the Schottky barrier decreases the positive photovoltage generated by the pn junction.

  5. A biometeorology study of climate and heat-related morbidity in Phoenix from 2001 to 2006

    NASA Astrophysics Data System (ADS)

    Golden, Jay S.; Hartz, Donna; Brazel, Anthony; Luber, George; Phelan, Patrick

    2008-07-01

    Heat waves kill more people in the United States than hurricanes, tornadoes, earthquakes, and floods combined. Recently, international attention focused on the linkages and impacts of human health vulnerability to urban climate when Western Europe experienced over 30,000 excess deaths during the heat waves of the summer of 2003—surpassing the 1995 heat wave in Chicago, Illinois, that killed 739. While Europe dealt with heat waves, in the United States, Phoenix, Arizona, established a new all-time high minimum temperature for the region on July 15, 2003. The low temperature of 35.5°C (96°F) was recorded, breaking the previous all-time high minimum temperature record of 33.8°C (93°F). While an extensive literature on heat-related mortality exists, greater understanding of influences of heat-related morbidity is required due to climate change and rapid urbanization influences. We undertook an analysis of 6 years (2001 2006) of heat-related dispatches through the Phoenix Fire Department regional dispatch center to examine temporal, climatic and other non-spatial influences contributing to high-heat-related medical dispatch events. The findings identified that there were no significant variations in day-of-week dispatch events. The greatest incidence of heat-related medical dispatches occurred between the times of peak solar irradiance and maximum diurnal temperature, and during times of elevated human comfort indices (combined temperature and relative humidity).

  6. A biometeorology study of climate and heat-related morbidity in Phoenix from 2001 to 2006.

    PubMed

    Golden, Jay S; Hartz, Donna; Brazel, Anthony; Luber, George; Phelan, Patrick

    2008-07-01

    Heat waves kill more people in the United States than hurricanes, tornadoes, earthquakes, and floods combined. Recently, international attention focused on the linkages and impacts of human health vulnerability to urban climate when Western Europe experienced over 30,000 excess deaths during the heat waves of the summer of 2003-surpassing the 1995 heat wave in Chicago, Illinois, that killed 739. While Europe dealt with heat waves, in the United States, Phoenix, Arizona, established a new all-time high minimum temperature for the region on July 15, 2003. The low temperature of 35.5 degrees C (96 degrees F) was recorded, breaking the previous all-time high minimum temperature record of 33.8 degrees C (93 degrees F). While an extensive literature on heat-related mortality exists, greater understanding of influences of heat-related morbidity is required due to climate change and rapid urbanization influences. We undertook an analysis of 6 years (2001-2006) of heat-related dispatches through the Phoenix Fire Department regional dispatch center to examine temporal, climatic and other non-spatial influences contributing to high-heat-related medical dispatch events. The findings identified that there were no significant variations in day-of-week dispatch events. The greatest incidence of heat-related medical dispatches occurred between the times of peak solar irradiance and maximum diurnal temperature, and during times of elevated human comfort indices (combined temperature and relative humidity).

  7. Use of ambulance dispatch data as an early warning system for communitywide influenzalike illness, New York City.

    PubMed

    Mostashari, Farzad; Fine, Annie; Das, Debjani; Adams, John; Layton, Marcelle

    2003-06-01

    In 1998, the New York City Department of Health and the Mayor's Office of Emergency Management began monitoring the volume of ambulance dispatch calls as a surveillance tool for biologic terrorism. We adapted statistical techniques designed to measure excess influenza mortality and applied them to outbreak detection using ambulance dispatch data. Since 1999, we have been performing serial daily regressions to determine the alarm threshold for the current day. In this article, we evaluate this approach by simulating a series of 2,200 daily regressions. In the influenza detection implementation of this model, there were 71 (3.2%) alarms at the 99% level. Of these alarms, 64 (90%) occurred shortly before or during a period of peak influenza in each of six influenza seasons. In the bioterrorism detection implementation of this methodology, after accounting for current influenza activity, there were 24 (1.1%) alarms at the 99% level. Two occurred during a large snowstorm, 1 is unexplained, and 21 occurred shortly before or during a period of peak influenza activity in each of six influenza seasons. Our findings suggest that this surveillance system is sensitive to communitywide respiratory outbreaks with relatively few false alarms. More work needs to be done to evaluate the sensitivity of this approach for detecting nonrespiratory illness and more localized outbreaks.

  8. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    NASA Astrophysics Data System (ADS)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing three types of retail rates (a flat rate, a time-of-use rate, and real-time pricing) from these wholesale price profiles, I examine bill savings from PV generation for the ten wholesale market scenarios under net metering and an alternative to net metering where hourly excess PV generation is compensated at the wholesale price. Most generally, I challenge the common assertion that PV compensation is likely to stay constant (or rise) due to constant (or rising) retail rates, and find that future electricity market scenarios can drive substantial changes in residential retail rates and that these changes, in concert with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV.

  9. A new maximum power tracking in PV system during partially shaded conditions based on shuffled frog leap algorithm

    NASA Astrophysics Data System (ADS)

    Sridhar, R.; Jeevananthan, S.; Dash, S. S.; Vishnuram, Pradeep

    2017-05-01

    Maximum Power Point Trackers (MPPTs) are power electronic conditioners used in photovoltaic (PV) system to ensure that PV structures feed maximum power for the given ambient temperature and sun's irradiation. When the PV panels are shaded by a fraction due to any environment hindrances then, conventional MPPT trackers may fail in tracking the appropriate peak power as there will be multi power peaks. In this work, a shuffled frog leap algorithm (SFLA) is proposed and it successfully identifies the global maximum power point among other local maxima. The SFLA MPPT is compared with a well-entrenched conventional perturb and observe (P&O) MPPT algorithm and a global search particle swarm optimisation (PSO) MPPT. The simulation results reveal that the proposed algorithm is highly advantageous than P&O, as it tracks nearly 30% more power for a given shading pattern. The credible nature of the proposed SFLA is ensured when it outplays PSO MPPT in convergence. The whole system is realised in MATLAB/Simulink environment.

  10. Noninvasive Uterine Electromyography For Prediction of Preterm Delivery*

    PubMed Central

    UCOVNIK, Miha L; MANER, William L.; CHAMBLISS, Linda R.; BLUMRICK, Richard; BALDUCCI, James; NOVAK-ANTOLIC, Ziva; GARFIELD, Robert E.

    2011-01-01

    Objective Power spectrum (PS) of uterine electromyography (EMG) can identify true labor. EMG propagation velocity (PV) to diagnose labor has not been reported. The objective was to compare uterine EMG against current methods to predict preterm delivery. Study design EMG was recorded in 116 patients (preterm labor, n=20; preterm non-labor, n=68; term labor, n=22; term non-labor, n=6). Student’s t-test was used to compare EMG values for labor vs. non-labor (P<0.05 significant). Predictive values of EMG, Bishop-score, contractions on tocogram, and transvaginal cervical length were calculated using receiver-operator-characteristics analysis. Results PV was higher in preterm and term labor compared with non-labor (P<0.001). Combined PV and PS peak frequency predicted preterm delivery within 7 days with area-under-the-curve (AUC) = 0.96. Bishop score, contractions, and cervical length had AUC of 0.72, 0.67, and 0.54. Conclusions Uterine EMG PV and PS peak frequency more accurately identify true preterm labor than clinical methods. PMID:21145033

  11. Analysis of a Concentrated Solar Thermophotovoltaic System with Thermal Energy Storage

    NASA Astrophysics Data System (ADS)

    Seyf, Hamid Reza; Henry, Asegun

    2017-01-01

    We analyzed a high temperature concentrated solar thermophotovoltaic (TPV) system with thermal energy storage (TES), which is enabled by the potential usage of liquid metal as a high temperature heat transfer fluid. The system concept combines the great advantages of TES with the potential for low cost and high performance derived from photovoltaic cells fabricated on reusable substrates, with a high reflectivity back reflector for photon recycling. The TES makes the electricity produced dispatchable, and thus the system studied should be compared to technologies such as concentrated solar power (CSP) with TES (e.g., using a turbine) or PV with electrochemical batteries, instead of direct and intermittent electricity generation from flat plate PV alone. Thus, the addition of TES places the system in a different class than has previously been considered and based on the model results, appears worthy of increased attention. The system level analysis presented identifies important cell level parameters that have the greatest impact on the overall system performance, and as a result can help to set the priorities for future TPV cell development.

  12. Analysis of a Concentrated Solar Thermophotovoltaic System with Thermal Energy Storage

    NASA Astrophysics Data System (ADS)

    Seyf, Hamid Reza; Henry, Asegun

    We analyzed a high temperature concentrated solar thermophotovoltaic (TPV) system with thermal energy storage (TES), which is enabled by the potential usage of liquid metal as a high temperature heat transfer fluid. The system concept combines the great advantages of TES with the potential for low cost and high performance derived from photovoltaic cells fabricated on reusable substrates, with a high reflectivity back reflector for photon recycling. The TES makes the electricity produced dispatchable, and thus the system studied should be compared to technologies such as concentrated solar power (CSP) with TES (e.g., using a turbine) or PV with electrochemical batteries, instead of direct and intermittent electricity generation from flat plate PV alone. Thus, the addition of TES places the system in a different class than has previously been considered and based on the model results, appears worthy of increased attention. The system level analysis presented identifies important cell level parameters that have the greatest impact on the overall system performance, and as a result can help to set the priorities for future TPV cell development.

  13. Impact of protein and carbohydrate supplementation on plasma volume expansion and thermoregulatory adaptation by aerobic training in older men.

    PubMed

    Okazaki, Kazunobu; Ichinose, Takashi; Mitono, Hiroyuki; Chen, Mian; Masuki, Shizue; Endoh, Hiroshi; Hayase, Hideki; Doi, Tatsuya; Nose, Hiroshi

    2009-09-01

    We examined whether protein-carbohydrate (CHO) supplementation immediately after exercise each day during aerobic training facilitated plasma volume (PV) expansion and thermoregulatory and cardiovascular adaptations in older men. Fourteen moderately active older men [68 +/- 5 (SD) yr] were divided into two groups so as to have no significant differences in anthropometric measures, PV, and peak oxygen consumption rate (Vo(2peak)). Each group was provided with a mixture of protein and CHO (3.2 kcal, 0.18 g protein/kg body wt, Pro-CHO, n = 7) or a non-protein and low-calorie placebo (0.5 kcal, 0 g protein/kg body wt, CNT, n = 7) immediately after cycling exercise (60-75% Vo(2peak), 60 min/day, 3 days/wk) each day for 8 wk at approximately 19 degrees C ambient temperature (T(a)) and approximately 43% relative humidity (RH). Before and after training, we measured PV, cardiac stroke volume (SV), and esophageal temperature (T(es)) during 20-min exercise at 60% of pretraining Vo(2peak) at 30 degrees C T(a) and 50% RH. Moreover, we determined the sensitivity of the chest sweat rate (DeltaSR/DeltaT(es)) and forearm vascular conductance (DeltaFVC/DeltaT(es)) in response to increased T(es) during exercise. After training, PV increased by approximately 6% in Pro-CHO (P < 0.001), with an approximately 10% increase in SV during exercise (P < 0.001), but not in CNT (P > 0.07). DeltaFVC/DeltaT(es) increased by 80% and DeltaSR/DeltaT(es) by 18% in Pro-CHO (both P < 0.01) but not in CNT (P > 0.07). Moreover, we found a significant interactive effect of group x training on PV, SV, and DeltaFVC/DeltaT(es) (all P < 0.02) but with no significant effect of group (P > 0.4), suggesting that the supplement enhanced these responses to aerobic training. Thus postexercise protein-CHO supplementation during training caused PV expansion and facilitated thermoregulatory and cardiovascular adaptations, possibly providing a new training regimen for older men.

  14. Retaining the Value of PV at High Penetration Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, Sarah; Bolen, Michael

    PV prices have dropped and are now attractive without incentives for peaking applications in some locations. Modeling suggests and, empirically, some regions demonstrate that as PV penetration increases its value decreases, predominantly due to a decrease in energy and capacity value. It is not apparent what technologies and price may be needed for PV to supply tens of percent of electricity in the most economically efficient manner. A 1-day workshop was co-sponsored by EPRI and NREL with support from ASU. A dozen presentations and discussions introduced how the interplay of various technologies impact the value of PV, identified technical challengesmore » and gaps impeding implementation, and discussed future R&D needs and opportunities.« less

  15. Net-zero Building Cluster Simulations and On-line Energy Forecasting for Adaptive and Real-Time Control and Decisions

    NASA Astrophysics Data System (ADS)

    Li, Xiwang

    Buildings consume about 41.1% of primary energy and 74% of the electricity in the U.S. Moreover, it is estimated by the National Energy Technology Laboratory that more than 1/4 of the 713 GW of U.S. electricity demand in 2010 could be dispatchable if only buildings could respond to that dispatch through advanced building energy control and operation strategies and smart grid infrastructure. In this study, it is envisioned that neighboring buildings will have the tendency to form a cluster, an open cyber-physical system to exploit the economic opportunities provided by a smart grid, distributed power generation, and storage devices. Through optimized demand management, these building clusters will then reduce overall primary energy consumption and peak time electricity consumption, and be more resilient to power disruptions. Therefore, this project seeks to develop a Net-zero building cluster simulation testbed and high fidelity energy forecasting models for adaptive and real-time control and decision making strategy development that can be used in a Net-zero building cluster. The following research activities are summarized in this thesis: 1) Development of a building cluster emulator for building cluster control and operation strategy assessment. 2) Development of a novel building energy forecasting methodology using active system identification and data fusion techniques. In this methodology, a systematic approach for building energy system characteristic evaluation, system excitation and model adaptation is included. The developed methodology is compared with other literature-reported building energy forecasting methods; 3) Development of the high fidelity on-line building cluster energy forecasting models, which includes energy forecasting models for buildings, PV panels, batteries and ice tank thermal storage systems 4) Small scale real building validation study to verify the performance of the developed building energy forecasting methodology. The outcomes of this thesis can be used for building cluster energy forecasting model development and model based control and operation optimization. The thesis concludes with a summary of the key outcomes of this research, as well as a list of recommendations for future work.

  16. The Potential for Energy Storage to Provide Peaking Capacity in California under Increased Penetration of Solar Photovoltaics: Report Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul L; Margolis, Robert M

    Opportunities to provide peaking capacity with low-cost energy storage are emerging. But adding storage changes the ability of subsequent storage additions to meet peak demand. Increasing photovoltaic (PV) deployment also affects storage's ability to provide peak capacity. This study examines storage's potential to replace conventional peak capacity in California.

  17. The 4-Day Wave as Observed from the Upper Atmosphere Research Satellite Microwave Limb Sounder

    NASA Technical Reports Server (NTRS)

    Allen, D. R.; Stanford, J. L.; Elson, L. S.; Fishbein, E. F.; Froidevaux, L.; Waters, J. W.

    1997-01-01

    The "4-day wave" is an eastward moving quasi-nondispersive feature with period near 4 days occurring near the winter polar stratopause. This paper presents evidence of the 4-day feature in Microwave Limb Sounder (MLS) temperature, geopotential height, and ozone data from the late southern winters of 1992 and 1993. Space-time spectral analyses reveal a double-peaked temperature structure consisting of one peak near the stratopause and another in the lower mesosphere, with an out-of-phase relationship between the two peaks. This double- peaked structure is reminiscent of recent three-dimensional barotropic/baroclinic instability model predictions and is observed here for the first time. The height variation of the 4-day ozone signal is shown to compare well with a linear advective-photochemical tracer model. Negative regions of quasigeostrophic potential vorticity (PV) gradient and positive Eliassen-Palm flux divergence are shown to occur, consistent with instability dynamics playing a role in wave forcing. Spectral analyses of PV derived from MLS geopotential height fields reveal a 4-day signal peaking near the polar stratopause. The three-dimensional structure of the 4-day wave resembles the potential vorticity "charge" concept, wherein a PV anomaly in the atmosphere (analogous to an electrical charge in a dielectric material) induces a geopotential field, a vertically oriented temperature dipole, and circulation about the vertical axis.

  18. Flat-plate solar array project of the US Department of Energy's National Photovoltaics Program: Ten years of progress

    NASA Technical Reports Server (NTRS)

    Christensen, Elmer

    1985-01-01

    The Flat-Plate Solar Array (FSA) Project, a Government-sponsored photovoltaics project, was initiated in January 1975 (previously named the Low-Cost Silicon Solar Array Project) to stimulate the development of PV systems for widespread use. Its goal then was to develop PV modules with 10% efficiency, a 20-year lifetime, and a selling price of $0.50 per peak watt of generating capacity (1975 dollars). It was recognized that cost reduction of PV solar-cell and module manufacturing was the key achievement needed if PV power systems were to be economically competitive for large-scale terrestrial use.

  19. Helicopter-based emergency medical services for a sparsely populated region: A study of 42,500 dispatches.

    PubMed

    Østerås, Ø; Brattebø, G; Heltne, J-K

    2016-05-01

    The Helicopter Emergency Medical Service (HEMS) in Norway is operated day and night, despite challenging geography and weather. In Western Norway, three ambulance helicopters, with a rapid response car as an alternative, cover close to 1 million inhabitants in an area of 45,000 km(2) . Our objective was to assess patterns of emergency medical problems and treatments in HEMS in a geographically large, but sparsely populated region. Data from all HEMS dispatches during 2004-2013 were assessed retrospectively. Information was analyzed with respect to patient treatment and characteristics, in addition to variations in services use during the day, week, and seasons. A total of 42,456 dispatches were analyzed. One third of the patients encountered were severely ill or injured, and two thirds of these received advanced treatment. Median activation time and on-scene time in primary helicopter missions were 5 and 11 min, respectively. Most patients (95%) were reached within 45 min by helicopter or rapid response car. Patterns of use did not change. More than one third of all dispatches were declined or aborted, mostly due to no longer medical indication, bad weather conditions, or competing missions. One third of the patients encountered were severely ill or injured, and more than two thirds of these received advanced treatment. HEMS use did not change over the 10-year period, however HEMS use peaked during daytime, weekends, and the summer. More than one third of all dispatches were declined or aborted. © 2015 The Authors. Acta Anaesthesiologica Scandinavica published by John Wiley & Sons Ltd on behalf of Acta Anaesthesiologica Scandinavica Foundation.

  20. Practical design considerations for photovoltaic power station

    NASA Astrophysics Data System (ADS)

    Swanson, T. D.

    Aspects of photovoltaic (PV) technology are discussed along with generic PV design considerations, taking into account the resource sunlight, PV modules and their reliability, questions of PV system design, the support structure subsystem, and a power conditioning unit subsystem. A description is presented of two recent projects which demonstrate the translation of an idea into actual working PV systems. A privately financed project in Denton, Maryland, went on line in early December, 1982, and began providing power to the local utility grid. It represents the first intermediate size, grid-connected, privately financed power station in the U.S. Based on firm quotes, the actual cost of this system is about $13/W peak. The other project, called the PV Breeder, is an energy independent facility which utilizes solar power to make new solar cells. It is also the first large industrial structure completely powered by the sun.

  1. New Mexico State Energy Research and Development Program contribution to Lovington 100-Kilowatt Photovoltaic Project

    NASA Astrophysics Data System (ADS)

    Risser, V. V.

    1982-06-01

    In 1977 the New Mexico State Energy Research and Development (R & D) Program provided $25,000 to the New Mexico Solar Energy Institute to be used in conjunction with US Department of Energy (DOE) funding for design, engineering, and installation of a proposed 150-kilowatt peak photovoltaic (PV) system in Lovington, New Mexico. An additional $75,000 was also committed contingent on award of a contract for construction, test, and evaluation of the system. This award was made in 1979 and the PV system was completed in 1981. Even though budget constraints dictated reduction of the plant size to 100-kilowatts peak, this system has produced more energy than any other flat-plate PV system in the world. The utilization of the R & D Program funding in contributing to the success of this important New Mexico energy project is detailed.

  2. Measurement of inflight shell areal density perturbations in NIF capsule implosions near peak velocity

    NASA Astrophysics Data System (ADS)

    Hammel, B. A.; Pickworth, L.; Smalyuk, V.; Macphee, A.; Scott, H. A.; Robey, H.; Barrios, M.; Regan, S. P.

    2015-11-01

    Quantitative measurements of shell-RhoR perturbations in capsules near peak implosion velocity (PV) are challenging. An external backlighter samples both sides of the shell, unless a re-entrant cone is used (potentially perturbing implosion). Emission from the hot core, after shock-stagnation and prior to PV, has been used as a self-backlighter, providing a means to sample one side of the capsule. Adding high-Z gas (~ 1% Ar) to the capsule fill in Symcaps (4He), has produced a continuum backlighter with significant increase in emission at photon energies ~ 8 keV over nominal fills. From images of the transmitted self-emission, above and below the K-edge of an internally doped Cu layer, we infer the growth at PV of imposed perturbations (100 nm amplitude, mode 40). Prepared by LLNL under Contract DE-AC52-07NA27344.

  3. Relationship Between Selected Strength and Power Assessments to Peak and Average Velocity of the Drive Block in Offensive Line Play.

    PubMed

    Jacobson, Bert H; Conchola, Eric C; Smith, Doug B; Akehi, Kazuma; Glass, Rob G

    2016-08-01

    Jacobson, BH, Conchola, EC, Smith, DB, Akehi, K, and Glass, RG. Relationship between selected strength and power assessments to peak and average velocity of the drive block in offensive line play. J Strength Cond Res 30(8): 2202-2205, 2016-Typical strength training for football includes the squat and power clean (PC) and routinely measured variables include 1 repetition maximum (1RM) squat and 1RM PC along with the vertical jump (VJ) for power. However, little research exists regarding the association between the strength exercises and velocity of an actual on-the-field performance. The purpose of this study was to investigate the relationship of peak velocity (PV) and average velocity (AV) of the offensive line drive block to 1RM squat, 1RM PC, the VJ, body mass (BM), and body composition. One repetition maximum assessments for the squat and PC were recorded along with VJ height, BM, and percent body fat. These data were correlated with PV and AV while performing the drive block. Peal velocity and AV were assessed using a Tendo Power and Speed Analyzer as the linemen fired, from a 3-point stance into a stationary blocking dummy. Pearson product analysis yielded significant (p ≤ 0.05) correlations between PV and AV and the VJ, the squat, and the PC. A significant inverse association was found for both PV and AV and body fat. These data help to confirm that the typical exercises recommended for American football linemen is positively associated with both PV and AV needed for the drive block effectiveness. It is recommended that these exercises remain the focus of a weight room protocol and that ancillary exercises be built around these exercises. Additionally, efforts to reduce body fat are recommended.

  4. Fixed-speed and Variable-speed Pumped Storage Dispatch Model in Power Systems with High Renewable Penetration

    NASA Astrophysics Data System (ADS)

    Yuan, Bo; Zong, Jin; Xu, Zhicheng

    2018-06-01

    According to different operating characteristics of pumped storage fixed speed unit and variable speed unit, a joint dispatching model of pumped storage unit and other types of units based on mixed integer linear optimization is constructed. The model takes into account the operating conditions, reservoir capacity, cycle type and other pumped storage unit constraints, but also consider the frequent start and stop and the stability of the operation of the unit caused by the loss. Using the Cplex solver to solve the model, the empirical example of the provincial power grid shows that the model can effectively arrange the pumping storage speed and the dispatching operation of the variable speed unit under the precondition of economic life of the unit, and give full play to the function of peak shaving and accommodating new energy. Because of its more flexible regulation characteristics of power generation and pumping conditions, the variable speed unit can better improve the operating conditions of other units in the system and promote the new energy dissipation.

  5. Intra-Hour Dispatch and Automatic Generator Control Demonstration with Solar Forecasting - Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coimbra, Carlos F. M.

    2016-02-25

    In this project we address multiple resource integration challenges associated with increasing levels of solar penetration that arise from the variability and uncertainty in solar irradiance. We will model the SMUD service region as its own balancing region, and develop an integrated, real-time operational tool that takes solar-load forecast uncertainties into consideration and commits optimal energy resources and reserves for intra-hour and intra-day decisions. The primary objectives of this effort are to reduce power system operation cost by committing appropriate amount of energy resources and reserves, as well as to provide operators a prediction of the generation fleet’s behavior inmore » real time for realistic PV penetration scenarios. The proposed methodology includes the following steps: clustering analysis on the expected solar variability per region for the SMUD system, Day-ahead (DA) and real-time (RT) load forecasts for the entire service areas, 1-year of intra-hour CPR forecasts for cluster centers, 1-year of smart re-forecasting CPR forecasts in real-time for determination of irreducible errors, and uncertainty quantification for integrated solar-load for both distributed and central stations (selected locations within service region) PV generation.« less

  6. Acute effects of elastic bands during the free-weight barbell back squat exercise on velocity, power, and force production.

    PubMed

    Stevenson, Mark W; Warpeha, Joseph M; Dietz, Cal C; Giveans, Russell M; Erdman, Arthur G

    2010-11-01

    The use of elastic bands in resistance training has been reported to be effective in increasing performance-related parameters such as power, rate of force development (RFD), and velocity. The purpose of this study was to assess the following measures during the free-weight back squat exercise with and without elastic bands: peak and mean velocity in the eccentric and concentric phases (PV-E, PV-C, MV-E, MV-C), peak force (PF), peak power in the concentric phase, and RFD immediately before and after the zero-velocity point and in the concentric phase (RFDC). Twenty trained male volunteers (age = 26.0 ± 4.4 years) performed 3 sets of 3 repetitions of squats (at 55% one repetition maximum [1RM]) on 2 separate days: 1 day without bands and the other with bands in a randomized order. The added band force equaled 20% of the subjects' 55% 1RM. Two independent force platforms collected ground reaction force data, and a 9-camera motion capture system was used for displacement measurements. The results showed that PV-E and RFDC were significantly (p < 0.05) greater with the use of bands, whereas PV-C and MV-C were greater without bands. There were no differences in any other variables. These results indicate that there may be benefits to performing squats with elastic bands in terms of RFD. Practitioners concerned with improving RFD may want to consider incorporating this easily implemented training variation.

  7. Forecasting residential solar photovoltaic deployment in California

    DOE PAGES

    Dong, Changgui; Sigrin, Benjamin; Brinkman, Gregory

    2016-12-06

    Residential distributed photovoltaic (PV) deployment in the United States has experienced robust growth, and policy changes impacting the value of solar are likely to occur at the federal and state levels. To establish a credible baseline and evaluate impacts of potential new policies, this analysis employs multiple methods to forecast residential PV deployment in California, including a time-series forecasting model, a threshold heterogeneity diffusion model, a Bass diffusion model, and National Renewable Energy Laboratory's dSolar model. As a baseline, the residential PV market in California is modeled to peak in the early 2020s, with a peak annual installation of 1.5-2more » GW across models. We then use the baseline results from the dSolar model and the threshold model to gauge the impact of the recent federal investment tax credit (ITC) extension, the newly approved California net energy metering (NEM) policy, and a hypothetical value-of-solar (VOS) compensation scheme. We find that the recent ITC extension may increase annual PV installations by 12%-18% (roughly 500 MW, MW) for the California residential sector in 2019-2020. The new NEM policy only has a negligible effect in California due to the relatively small new charges (< 100 MW in 2019-2020). Moreover, impacts of the VOS compensation scheme (0.12 cents per kilowatt-hour) are larger, reducing annual PV adoption by 32% (or 900-1300 MW) in 2019-2020.« less

  8. Forecasting residential solar photovoltaic deployment in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Changgui; Sigrin, Benjamin; Brinkman, Gregory

    Residential distributed photovoltaic (PV) deployment in the United States has experienced robust growth, and policy changes impacting the value of solar are likely to occur at the federal and state levels. To establish a credible baseline and evaluate impacts of potential new policies, this analysis employs multiple methods to forecast residential PV deployment in California, including a time-series forecasting model, a threshold heterogeneity diffusion model, a Bass diffusion model, and National Renewable Energy Laboratory's dSolar model. As a baseline, the residential PV market in California is modeled to peak in the early 2020s, with a peak annual installation of 1.5-2more » GW across models. We then use the baseline results from the dSolar model and the threshold model to gauge the impact of the recent federal investment tax credit (ITC) extension, the newly approved California net energy metering (NEM) policy, and a hypothetical value-of-solar (VOS) compensation scheme. We find that the recent ITC extension may increase annual PV installations by 12%-18% (roughly 500 MW, MW) for the California residential sector in 2019-2020. The new NEM policy only has a negligible effect in California due to the relatively small new charges (< 100 MW in 2019-2020). Moreover, impacts of the VOS compensation scheme (0.12 cents per kilowatt-hour) are larger, reducing annual PV adoption by 32% (or 900-1300 MW) in 2019-2020.« less

  9. Development of an Advanced Grid-Connected PV-ECS System Considering Solar Energy Estimation

    NASA Astrophysics Data System (ADS)

    Rahman, Md. Habibur; Yamashiro, Susumu; Nakamura, Koichi

    In this paper, the development and the performance of a viable distributed grid-connected power generation system of Photovoltaic-Energy Capacitor System (PV-ECS) considering solar energy estimation have been described. Instead of conventional battery Electric Double Layer Capacitors (EDLC) are used as storage device and Photovoltaic (PV) panel to generate power from solar energy. The system can generate power by PV, store energy when the demand of load is low and finally supply the stored energy to load during the period of peak demand. To realize the load leveling function properly the system will also buy power from grid line when load demand is high. Since, the power taken from grid line depends on the PV output power, a procedure has been suggested to estimate the PV output power by calculating solar radiation. In order to set the optimum value of the buy power, a simulation program has also been developed. Performance of the system has been studied for different load patterns in different weather conditions by using the estimated PV output power with the help of the simulation program.

  10. Performance evaluation of a 2-mode PV grid connected system in Thailand -- Case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jivacate, C.; Mongconvorawan, S.; Sinratanapukdee, E.

    A PV grid connected system with small battery bank has been set up in a rural district, North Thailand in order to demonstrate a 2-mode operation concept. The objective is to gain experience on the PV grid connected concept without battery storage. However, due to the evening peak demand and a rather weak distribution grid which is typical in rural areas, small battery bank is still required to enable the maximum energy transfer to grid for the time being before moving fully to the no battery mode. The analyzed data seems to indicate possible performance improvement by re-arranging the numbermore » of PV modules and battery in the string.« less

  11. Solar San Diego: The Impact of Binomial Rate Structures on Real PV Systems; Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanGeet, O.; Brown, E.; Blair, T.

    2008-05-01

    There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savingsmore » that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rate structures is presented. The data revealed that actual demand and energy use benefits of binomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007.« less

  12. Vertical Jump Height is more Strongly Associated with Velocity and Work Performed Prior to Take-off

    NASA Technical Reports Server (NTRS)

    Bentley, J. R.; Loehr, J. A.; DeWitt, J. K.; Lee, S. M. C.; English, K. L.; Nash, R. E.; Leach, M. A.; Hagan, R. D.

    2008-01-01

    Vertical jump (VJ) height is commonly used as a measure of athletic capability in strength and power sports. Although VJ has been shown to be a predictor of athletic performance, it is not clear which kinetic ground reaction force (GRF) variables, such as peak force (PF), peak power (PP), peak velocity (PV), total work (TW) or impulse (Imp) are the best correlates. To determine which kinetic variables (PF, PP, PV, TW, and Imp) best correlate with VJ height. Twenty subjects (14 males, 6 females) performed three maximal countermovement VJs on a force platform (Advanced Mechanical Technology, Inc., Watertown, MA, USA). VJ jump height was calculated as the difference between standing reach and the highest reach point measured using a Vertec. PF, PP, PV, TW, and Imp were calculated using the vertical GRF data sampled at 1000 Hz from the lowest point in the countermovement through the concentric portion until take-off. GRF data were normalized to body mass measured using a standard scale (Detecto, Webb City, MO, USA). Correlation coefficients were computed between each GRF variable and VJ height using a Pearson correlation. VJ height (43.4 plus or minus 9.1 cm) was significantly correlated (p less than 0.001) with PF (998 plus or minus 321 N; r=0.51), PP (1997 plus or minus 772 W; r=0.69), PV (2.66 plus or minus 0.40 m (raised dot) s(sup -1); r=0.85), TW (259 plus or minus 93.0 kJ; r=0.82), and Imp (204 plus or minus 51.1 N(raised dot)s; r=0.67). Although all variables were correlated to VJ height, PV and TW were more strongly correlated to VJ height than PF, PP, and Imp. Therefore, since TW is equal to force times displacement, the relative displacement of the center of mass along with the forces applied during the upward movement of the jump are critical determinants of VJ height. PV and TW are key determinants of VJ height, and therefore successful training programs to increase VJ height should focus on rapid movement (PV) and TW by increasing power over time rather than focusing on PF alone.

  13. Developer view of the CSP evolution

    NASA Astrophysics Data System (ADS)

    Carvajal, Javier López; Barea, Jose M.; Barragan, Jose; Altmann, Thomas

    2017-06-01

    This paper briefly describes the history of CSP up to the present times and also gives some views about what could be expected in the near future for the industry. It also points out the relevance of the TES system as a key and gives some ideas regarding the innovations that could be expected in the coming CSP projects. Although currently, tower technology capacity under operation is less than 15% of the total CSP capacity in the world, solar tower, with molten salt most likely, might be the predominant technology in the medium run for electricity generation. In addition, other different concepts will be more commonly projected in order to increase dispatchability or renewable energy contribution in the electric system as hybridization with other technologies like PV or as part of desalination projects.

  14. Effects of different set configurations on barbell velocity and displacement during a clean pull.

    PubMed

    Haff, G Gregory; Whitley, Adrian; McCoy, Lora B; O'Bryant, Harold S; Kilgore, J Lon; Haff, Erin E; Pierce, Kyle; Stone, Michael H

    2003-02-01

    The effects of 3 types of set configurations (cluster, traditional, and undulating) on barbell kinematics were investigated in the present study. Thirteen men (track and field = 8; Olympic weightlifters = 5) (mean +/- SEM age, 23.4 +/- 1.1 years; height, 181.3 +/- 2.1 cm; body mass, 89.8 +/- 4.2 kg) performed 1 set of 5 repetitions in a cluster, traditional, and undulating fashion at 90 and 120% of their 1 repetition maximum (1RM) power clean (119.0 +/- 4.3 kg). All data were collected at 50 Hz and analyzed with a V-Scope Weightlifting Analysis System. Peak velocity (PV) and peak displacement (PD) were analyzed for each repetition and averaged for each set type. Results indicated that a significantly (p < 0.016) higher PV occurred during the cluster set when compared with the traditional sets at both intensities. PD was significantly higher than traditional sets at the 120% intensity. The present study suggests set configuration can affect PV and PD during clean pulls.

  15. Eastern Renewable Generation Integration Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bloom, Aaron; Townsend, Aaron; Palchak, David

    2016-08-01

    The Eastern Interconnection (EI) is one of the largest power systems in the world, and its size and complexity have historically made it difficult to study in high levels of detail in a modeling environment. In order to understand how this system might be impacted by high penetrations (30% of total annual generation) of wind and solar photovoltaic (PV) during steady state operations, the National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy (DOE) conducted the Eastern Renewable Generation Integration Study (ERGIS). This study investigates certain aspects of the reliability and economic efficiency problem faced by power systemmore » operators and planners. Specifically, the study models the ability to meet electricity demand at a 5-minute time interval by scheduling resources for known ramping events, while maintaining adequate reserves to meet random variation in supply and demand, and contingency events. To measure the ability to meet these requirements, a unit commitment and economic dispatch (UC&ED) model is employed to simulate power system operations. The economic costs of managing this system are presented using production costs, a traditional UC&ED metric that does not include any consideration of long-term fixed costs. ERGIS simulated one year of power system operations to understand regional and sub-hourly impacts of wind and PV by developing a comprehensive UC&ED model of the EI. In the analysis, it is shown that, under the study assumptions, generation from approximately 400 GW of combined wind and PV capacity can be balanced on the transmission system at a 5-minute level. In order to address the significant computational burdens associated with a model of this detail we apply novel computing techniques to dramatically reduce simulation solve time while simultaneously increasing the resolution and fidelity of the analysis. Our results also indicate that high penetrations of wind and PV (collectively variable generation (VG)), significantly impact the operation of traditional generating resources and cause these resources to be used less frequently and operate across a broader output range because wind and PV have lower operating costs and variable output levels.« less

  16. Defense Threat Reduction Agency > Research > DTRIAC > DTRIAC Dispatch

    Science.gov Websites

    @mail.mil with your submissions. DTRIAC Dispatch - Vol 5, Issue 3 DTRIAC Dispatch - Vol 5, Issue 2 DTRIAC Dispatch - Vol 5, Issue 1 DTRIAC Dispatch - Vol 4, Issue 1 DTRIAC Dispatch - Vol 3, Issue 4 DTRIAC Dispatch - Vol 3, Issue 3 DTRIAC Dispatch - Vol 3, Issue 2 DTRIAC Dispatch - Vol 3, Issue 1 DTRIAC Dispatch - Vol

  17. Integrated Building Energy Systems Design Considering Storage Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadler, Michael; Marnay, Chris; Siddiqui, Afzal

    The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic, as well as environmental attraction of micro-generation systems (e.g., PV or fuel cells with or without CHP) and contribute to enhanced demand response. The interactions among PV, solar thermal, and storage systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of storage technologies on demand response and CO2 emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that can pursue two strategies as its objective function.more » These two strategies are minimization of its annual energy costs or of its CO2 emissions. The problem is solved for a given test year at representative customer sites, e.g., nursing homes, to obtain not only the optimal investment portfolio, but also the optimal hourly operating schedules for the selected technologies. This paper focuses on analysis of storage technologies in micro-generation optimization on a building level, with example applications in New York State and California. It shows results from a two-year research projectperformed for the U.S. Department of Energy and ongoing work. Contrary to established expectations, our results indicate that PV and electric storage adoption compete rather than supplement each other considering the tariff structure and costs of electricity supply. The work shows that high electricity tariffs during on-peak hours are a significant driver for the adoption of electric storage technologies. To satisfy the site's objective of minimizing energy costs, the batteries have to be charged by grid power during off-peak hours instead of PV during on-peak hours. In contrast, we also show a CO2 minimization strategy where the common assumption that batteries can be charged by PV can be fulfilled at extraordinarily high energy costs for the site.« less

  18. Distributed photovoltaic system impact upon utility load/supply management practices

    NASA Astrophysics Data System (ADS)

    Vachtsevanos, G. J.; Meliopoulos, A. P.; Paraskevopoulos, B. K.

    A methodology is described for simulation of the economic and technical factors of photovoltaic (PV) installations interfacing with utility load/management operations. A probabalistic technique is used to model the expected demand, reliability of the generating units, costs and profits from each unit, expected unserviced energy, and the loss of load probability. The available power from PV arrays is treated stochastically with statistical weighting on the basis of site meteorological data. The goal is to include the PV power while minimizing operational costs, taking into account the level of penetration of the total PV output. Two sample simulations for a utility with a diverse generating mix demonstrate that overall costs would decrease in both cases with PVs on-line through the emphasis on cheaper-fueled generators and peak-load shaving when possible.

  19. Quantitative analysis of poliomyelitis-like paralysis in mice induced by a poliovirus replicon.

    PubMed

    Arita, Minetaro; Nagata, Noriyo; Sata, Tetsutaro; Miyamura, Tatsuo; Shimizu, Hiroyuki

    2006-11-01

    Poliovirus (PV) infection causes severe paralysis, typically of the legs, by destruction of the motor neurons in the spinal cord. In this study, the relationship between PV replication in the spinal cord, damage in the motor neurons and poliomyelitis-like paralysis was analysed in transgenic mice expressing the human PV receptor (TgPVR21). First, a PV replicon encoding firefly luciferase in place of the capsid genes (PV-Fluc mc) was trans-encapsidated in 293T cells and the trans-encapsidated PV-Fluc mc (TE-PV-Fluc mc) was then inoculated into the spinal cords of TgPVR21 mice. TE-PV-Fluc mc was recovered with a titre of 6.3 x 10(7) infectious units ml(-1), which was comparable to those of PV1 strains. TgPVR21 mice inoculated with TE-PV-Fluc mc showed non-lethal paralysis of the hindlimbs, with severity ranging from a decline in grip strength to complete flaccid paralysis. The replication of TE-PV-Fluc mc in the spinal cord reached peak levels at 10 h post-inoculation (p.i.), followed by the appearance of paralysis at as early as 12 h p.i., reaching a plateau at 16 h p.i. Histological analysis showed a correlation between the lesion and the severity of the clinical symptoms in most mice. However, severe paralysis could also be observed with an apparently low lesion score, where as few as 5.3 x 10(2) motor neurons (1.4 % of the susceptible cells in the lumbar cord) were infected by TE-PV-Fluc mc. These results indicate that PV replication in a small population of the motor neurons was critical for severe residual poliomyelitis-like paralysis in TgPVR21 mice.

  20. The Eastern Renewable Generation Integration Study: Insights on System Stress: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bloom, Aaron; Novacheck, Josh

    The Eastern Renewable Generation Integration Study (ERGIS) explores the operational impacts of the wide spread adoption of wind and solar photovoltaics (PV) resources in North America's Eastern and Quebec Interconnections. We explore the impact of large scale adoption of wind and solar generation on the unit commitment and economic dispatch of the largest coordinated power system in the world by simulating hourly and five-minute operations. Using NREL's high-performance computing capabilities and new methodologies to model operations, we found that the modeled system, as simulated with evolutionary change in 2026, could balance the variability and uncertainty of wind and solar PVmore » at a five-minute level under a variety of conditions. Our simulations achieve instantaneous penetrations that exceed 50% of load while meeting an annual penetration of 30% on an energy basis. The system meets balanced load and supply in all intervals, with modest curtailment, using technologies and practices that are widely available today. However, a variety of the conditions present in these simulations deviate substantially from historical practice. In this work, we analyze potentially stressful system conditions that occur in the simulations and identify opportunities for innovation, regulatory reform, and changes in operating practices that require further analysis to enable the transition to a system with more wind and solar PV.« less

  1. PV solar electricity: status and future

    NASA Astrophysics Data System (ADS)

    Hoffmann, Winfried

    2006-04-01

    Within the four main market segments of PV solar electricity there are already three areas competitive today. These are off-grid industrial and rural as well as consumer applications. The overall growth within the past 8 years was almost 40 % p.a. with a "normal" growth of about 18 % p.a. for the first three market segments whereas the grid connected market increased with an astonishing 63 % p.a. The different growth rates catapulted the contribution of grid connected systems in relation to the total market from about one quarter 6 years ago towards more than three quarters today. The reason for this development is basically due to industry-politically induced market support programs in the aforementioned countries. It is quite important to outline under which boundary conditions grid connected systems will be competitive without support programs like the feed in tariff system in Germany, Spain and some more to come in Europe as well as investment subsidies in Japan, US and some other countries. It will be shown that in a more and more liberalized utility market worldwide electricity produced by PV solar electricity systems will be able to compete with their generating cost against peak power prices from utilities. The point of time for this competitiveness is mainly determined by the following facts: 1. Price decrease for PV solar electricity systems leading to an equivalent decrease in the generated cost for PV produced kWh. 2. Development of a truly liberalized electricity market. 3. Degree of irradiation between times of peak power demand and delivery of PV electricity. The first topic is discussed using price experience curves. Some explanations will be given to correlate the qualitative number of 20 % price decrease for doubling cumulative worldwide sales derived from the historic price experience curve with a more quantitative analysis based on our EPIA-Roadmap (productivity increase and ongoing improvements for existing technologies as well as development of new concepts to broaden the product portfolio in coming years). The second topic outlines the most likely development of liberalized electricity markets in various regions worldwide. It will be emphasized that in such markets the future prices for electricity will more and more reflect the different cost for bulk and peak power production. This will not only happen for industrial electricity customers - as already today in many countries - but also for private households. The third topic summarizes the existing data and facts by correlating peak power demand and prices traded in various stock exchange markets with delivered PV kWh. It will be shown that a high degree of correlation is existent. Combining the three topics and postulating reverse net metering the competitiveness of PV solar electricity as described is most likely to occur. The described price decrease of modules will also have a very positive impact on off-grid rural applications, mainly in 3rd world countries. It will be shown that this is strongly advanced due to the development of mini-grids starting from solar home systems - with mini grids looking very similar to on-grid applications in weak grid areas of nowadays electricity network.

  2. Economic viability of photovoltaic power for development assistance applications

    NASA Technical Reports Server (NTRS)

    Bifano, W. J.

    1982-01-01

    This paper briefly discusses the development assistance market and examines a number of specific photovoltaic (PV) development assistance field tests, including water pumping/grain grinding (Tangaye, Upper Volta), vaccine refrigerators slated for deployment in 24 countries, rural medical centers to be installed in Ecuador, Guyana, Kenya and Zimbabwe, and remote earth stations to be deployed in the near future. A comparison of levelized energy cost for diesel generators and PV systems covering a range of annual energy consumptions is also included. The analysis does not consider potential societal, environmental or political benefits associated with PV power. PV systems are shown to be competitive with diesel generators, based on life cycle cost considerations, assuming a system price of $20/W(peak), for applications having an annual energy demand of up to 6000 kilowatt-hours per year.

  3. Qualification testing and electrical measurement experience: A manufacturer's view

    NASA Astrophysics Data System (ADS)

    Arnett, J. C.; Cooley, J. E.; Wingert, T. L.

    1983-11-01

    ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

  4. Qualification testing and electrical measurement experience: A manufacturer's view

    NASA Technical Reports Server (NTRS)

    Arnett, J. C.; Cooley, J. E.; Wingert, T. L.

    1983-01-01

    ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

  5. Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Austin; Martin, Gregory; Hurtt, James

    As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 with Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and volt-age/frequency ride-through, among others. A comparative experimental evaluation has been completed on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and the effect on abnormal grid conditionmore » response. This study examines the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. This report reviews comparative test data, which shows that GSFs have little impact on the metrics of interest in most tests cases.« less

  6. Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Austin A; Martin, Gregory D; Hurtt, James

    As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormalmore » grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.« less

  7. Solar San Diego: The Impact of Binomial Rate Structures on Real PV-Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Geet, O.; Brown, E.; Blair, T.

    2008-01-01

    There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savingsmore » that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rates structures is presented. The data revealed that actual demand and energy use benefits of bionomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007. Future work will include combining demand and electricity charges and increasing the breadth of rate structures tested, including the impacts of non-coincident demand charges.« less

  8. Usefulness of Doppler assessment of pulmonary vein and left atrial appendage flow following pulmonary vein isolation of chronic atrial fibrillation in predicting recovery of left atrial function.

    PubMed

    Donal, Erwan; Grimm, Richard A; Yamada, Hirotsugu; Kim, Yong Jin; Marrouche, Nassir; Natale, Andrea; Thomas, James D

    2005-04-15

    Atrial fibrillation (AF) is a widespread condition that causes significant morbidity and mortality. Recently, pulmonary venous (PV) isolation using radiofrequency ablation has been used successfully to exclude the pulmonary venous ostia, resulting in correction of AF. Further, miniaturized high-frequency ultrasound phased-array transducers currently provide Doppler and 2-dimensional imaging during the ablation procedure. We examined atrial function and its determinants using intracardiac echocardiography before and after PV isolation in 45 patients who had chronic AF (56 +/- 11 years old). PV, left atrial (LA) appendage, and mitral and tricuspid flows were recorded. Recovery of booster pump function (defined by the presence of mitral inflow A wave, LA appendage a-wave, and PV A-reversal wave velocities >10 cm/s) was observed in 39 of 45 patients (86.6%). PV flow systolic wave before and after ablation correlated with the degree of LA booster pump function after PV isolation. An early systolic PV flow peak velocity >57.47 cm/s predicted "good" LA booster pump function recovery with 96% specificity. Diastolic LA appendage emptying in AF correlated (p <0.001) and predicted good LA booster pump function with 92% specificity for velocities >46.4 cm/s. Thus, monitoring LA function during PV isolation for chronic AF is feasible. Most patients recovered LA booster pump function immediately after PV isolation, and the degree of recovery correlated with LA reservoir function. Preserved reservoir function during AF is predictive of satisfactory recovery of booster pump function after PV isolation.

  9. Development and Evaluation of Control System for Microgrid Supplying Heat and Electricity

    NASA Astrophysics Data System (ADS)

    Kojima, Yasuhiro; Koshio, Masanobu; Nakamura, Shizuka

    Photovoltaic (PV) and Wind Turbine (WT) generation systems are expected to offer solutions to reduce green house gases and become more widely used in the future. However, the chief technical drawback of using these kinds of weather-dependent generators is the difficulty of forecasting their output, which can have negative impacts on commercial grids if a large number of them are introduced. Thus, this problem may hinder the wider application of PV and WT generation systems. The Regional Power Grid with Renewable Energy Resources Project was launched to seek a solution to this problem. The scope of the project is to develop, operate, and evaluate a Dispersed Renewable Energy Supply System with the ability to adapt the total energy output in response to changes in weather and demand. Such a system would reduce the impact that PV and WT generation systems have on commercial grids and allow the interconnection of more Dispersed Energy Resources (DER). In other words, the main objective of this project is to demonstrate an integrated energy management system, or a type of microgrid [1], as a new way of introducing DERs. The system has been in operation since October 2005 and will continue operation until March 2008. Through the project period, the data on power quality, system efficiency, operation cost, and environmental burden will be gathered and a cost-benefit analysis of the system will be undertaken. In this paper, firstly we introduce the concept of microgrid for reducing negative impact of natural energy, and secondly illustrate the structure of electric and thermal supply control system for Microgrid, especially for the Hachinohe demonstration project. The control system consists of four stages; weekly operation planning, economic dispatching control, tie-line control and local frequency control. And finally demonstration results and evaluation results are shown.

  10. Variability of a "force signature" during windmill softball pitching and relationship between discrete force variables and pitch velocity.

    PubMed

    Nimphius, Sophia; McGuigan, Michael R; Suchomel, Timothy J; Newton, Robert U

    2016-06-01

    This study assessed reliability of discrete ground reaction force (GRF) variables over multiple pitching trials, investigated the relationships between discrete GRF variables and pitch velocity (PV) and assessed the variability of the "force signature" or continuous force-time curve during the pitching motion of windmill softball pitchers. Intraclass correlation coefficient (ICC) for all discrete variables was high (0.86-0.99) while the coefficient of variance (CV) was low (1.4-5.2%). Two discrete variables were significantly correlated to PV; second vertical peak force (r(5)=0.81, p=0.03) and time between peak forces (r(5)=-0.79; p=0.03). High ICCs and low CVs support the reliability of discrete GRF and PV variables over multiple trials and significant correlations indicate there is a relationship between the ability to produce force and the timing of this force production with PV. The mean of all pitchers' curve-average standard deviation of their continuous force-time curves demonstrated low variability (CV=4.4%) indicating a repeatable and identifiable "force signature" pattern during this motion. As such, the continuous force-time curve in addition to discrete GRF variables should be examined in future research as a potential method to monitor or explain changes in pitching performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Optimal charge control strategies for stationary photovoltaic battery systems

    NASA Astrophysics Data System (ADS)

    Li, Jiahao; Danzer, Michael A.

    2014-07-01

    Battery systems coupled to photovoltaic (PV) modules for example fulfill one major function: they locally decouple PV generation and consumption of electrical power leading to two major effects. First, they reduce the grid load, especially at peak times and therewith reduce the necessity of a network expansion. And second, they increase the self-consumption in households and therewith help to reduce energy expenses. For the management of PV batteries charge control strategies need to be developed to reach the goals of both the distribution system operators and the local power producer. In this work optimal control strategies regarding various optimization goals are developed on the basis of the predicted household loads and PV generation profiles using the method of dynamic programming. The resulting charge curves are compared and essential differences discussed. Finally, a multi-objective optimization shows that charge control strategies can be derived that take all optimization goals into account.

  12. The peak velocity derived from the Carminatti Test is related to physical match performance in young soccer players.

    PubMed

    Fernandes-da-Silva, Juliano; Castagna, Carlo; Teixeira, Anderson Santiago; Carminatti, Lorival José; Guglielmo, Luiz Guilherme Antonacci

    2016-12-01

    The aim of this study was to examine the relationship between the peak velocity derived from the Carminatti Test (T-CAR) (PV T-CAR ) and physical match performance in young soccer players. Thirty-three youth soccer players were recruited from 2 non-professional clubs. Friendly matches and small-sided game were performed. Physical match demands were assessed using Global Positioning System (GPS) technology. On a separate occasion, the players were submitted to the T-CAR. Players were categorised into 3 groups based on their T-CAR performance: Low (PV T-CAR  ≤ P33), Intermediate (P33 > PV T-CAR  < P66) and High (PV T-CAR  ≥ P66). The PV T-CAR (15.5 ± 0.7 km·h -1 ) was significantly related to high-intensity activities (HIA; r = 0.78, P < 0.001), high-intensity running (HIR; r = 0.66, P < 0.001), sprinting (r = 0.62, P < 0.001) and total distance (TD) covered (r = 0.47, P < 0.01) during friendly matches. The PV T-CAR was strongly correlated with the amount of HIA (r = 0.81, P < 0.001), HIR (r = 0.85, P < 0.001) and TD covered (r = 0.81, P < 0.001) during small-sided game. No significant correlation was observed between the PV T-CAR and distance of sprinting (r = 0.49, P = 0.067) during small-side game. Furthermore, players in the High group covered significantly more TD (10%) and did more HIA (42%), sprinting (31%) and HIR (25%) during friendly matches compared to the players classified as having Low performance on the T-CAR. These differences still remained after adjusting for chronological age (CA), maturity and body size. In conclusion, the current study gives empirical support to the ecological and construct validity of this novel field test (T-CAR) as an indicator of match-related physical performance in young soccer players during pubertal years.

  13. Parallel dispatch: a new paradigm of electrical power system dispatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jun Jason; Wang, Fei-Yue; Wang, Qiang

    Modern power systems are evolving into sociotechnical systems with massive complexity, whose real-time operation and dispatch go beyond human capability. Thus, the need for developing and applying new intelligent power system dispatch tools are of great practical significance. In this paper, we introduce the overall business model of power system dispatch, the top level design approach of an intelligent dispatch system, and the parallel intelligent technology with its dispatch applications. We expect that a new dispatch paradigm, namely the parallel dispatch, can be established by incorporating various intelligent technologies, especially the parallel intelligent technology, to enable secure operation of complexmore » power grids, extend system operators U+02BC capabilities, suggest optimal dispatch strategies, and to provide decision-making recommendations according to power system operational goals.« less

  14. Operational adaptability evaluation index system of pumped storage in UHV receiving-end grids

    NASA Astrophysics Data System (ADS)

    Yuan, Bo; Zong, Jin; Feng, Junshu

    2017-01-01

    Pumped storage is an effective solution to deal with the emergency reserve shortage, renewable energy accommodating and peak-shaving problems in ultra-high voltage (UHV) transmission receiving-end grids. However, governments and public opinion in China tend to evaluate the operational effectiveness of pumped storage using annual utilization hour, which may result in unreasonable and unnecessary dispatch of pumped storage. This paper built an operational adaptability evaluation index system for pumped storage in UHV-receiving end grids from three aspects: security insurance, peak-shaving and renewable energy accommodating, which can provide a comprehensive and objective way to evaluate the operational performance of a pumped storage station.

  15. Microgrid to enable optimal distributed energy retail and end-user demand response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Ming; Feng, Wei; Marnay, Chris

    In the face of unprecedented challenges in environmental sustainability and grid resilience, there is an increasingly held consensus regarding the adoption of distributed and renewable energy resources such as microgrids (MGs), and the utilization of flexible electric loads by demand response (DR) to potentially drive a necessary paradigm shift in energy production and consumption patterns. However, the potential value of distributed generation and demand flexibility has not yet been fully realized in the operation of MGs. This study investigates the pricing and operation strategy with DR for a MG retailer in an integrated energy system (IES). Based on co-optimizing retailmore » rates and MG dispatch formulated as a mixed integer quadratic programming (MIQP) problem, our model devises a dynamic pricing scheme that reflects the cost of generation and promotes DR, in tandem with an optimal dispatch plan that exploits spark spread and facilitates the integration of renewables, resulting in improved retailer profits and system stability. Main issues like integrated energy coupling and customer bill reduction are addressed during pricing to ensure rates competitiveness and customer protection. By evaluating on real datasets, the system is demonstrated to optimally coordinate storage, renewables, and combined heat and power (CHP), reduce carbon dioxide emission while maintaining profits, and effectively alleviate the PV curtailment problem. Finally, the model can be used by retailers and MG operators to optimize their operations, as well as regulators to design new utility rates in support of the ongoing transformation of energy systems.« less

  16. Microgrid to enable optimal distributed energy retail and end-user demand response

    DOE PAGES

    Jin, Ming; Feng, Wei; Marnay, Chris; ...

    2018-06-07

    In the face of unprecedented challenges in environmental sustainability and grid resilience, there is an increasingly held consensus regarding the adoption of distributed and renewable energy resources such as microgrids (MGs), and the utilization of flexible electric loads by demand response (DR) to potentially drive a necessary paradigm shift in energy production and consumption patterns. However, the potential value of distributed generation and demand flexibility has not yet been fully realized in the operation of MGs. This study investigates the pricing and operation strategy with DR for a MG retailer in an integrated energy system (IES). Based on co-optimizing retailmore » rates and MG dispatch formulated as a mixed integer quadratic programming (MIQP) problem, our model devises a dynamic pricing scheme that reflects the cost of generation and promotes DR, in tandem with an optimal dispatch plan that exploits spark spread and facilitates the integration of renewables, resulting in improved retailer profits and system stability. Main issues like integrated energy coupling and customer bill reduction are addressed during pricing to ensure rates competitiveness and customer protection. By evaluating on real datasets, the system is demonstrated to optimally coordinate storage, renewables, and combined heat and power (CHP), reduce carbon dioxide emission while maintaining profits, and effectively alleviate the PV curtailment problem. Finally, the model can be used by retailers and MG operators to optimize their operations, as well as regulators to design new utility rates in support of the ongoing transformation of energy systems.« less

  17. Rapid disinhibition by adjustment of PV intrinsic excitability during whisker map plasticity in mouse S1.

    PubMed

    Gainey, Melanie A; Aman, Joseph W; Feldman, Daniel E

    2018-04-20

    Rapid plasticity of layer (L) 2/3 inhibitory circuits is an early step in sensory cortical map plasticity, but its cellular basis is unclear. We show that, in mice of either sex, 1 day whisker deprivation drives rapid loss of L4-evoked feedforward inhibition and more modest loss of feedforward excitation in L2/3 pyramidal (PYR) cells, increasing E-I conductance ratio. Rapid disinhibition was due to reduced L4-evoked spiking by L2/3 parvalbumin (PV) interneurons, caused by reduced PV intrinsic excitability. This included elevated PV spike threshold, associated with an increase in low-threshold, voltage activated delayed rectifier (presumed Kv1) and A-type potassium currents. Excitatory synaptic input and unitary inhibitory output of PV cells were unaffected. Functionally, the loss of feedforward inhibition and excitation were precisely coordinated in L2/3 PYR cells, so that peak feedforward synaptic depolarization remained stable. Thus, rapid plasticity of PV intrinsic excitability offsets early weakening of excitatory circuits to homeostatically stabilize synaptic potentials in PYR cells of sensory cortex. SIGNIFICANCE STATEMENT Inhibitory circuits in cerebral cortex are highly plastic, but the cellular mechanisms and functional importance of this plasticity are incompletely understood. We show that brief (1-day) sensory deprivation rapidly weakens parvalbumin (PV) inhibitory circuits by reducing the intrinsic excitability of PV neurons. This involved a rapid increase in voltage-gated potassium conductances that control near-threshold spiking excitability. Functionally, the loss of PV-mediated feedforward inhibition in L2/3 pyramidal cells was precisely balanced with the separate loss of feedforward excitation, resulting in a net homeostatic stabilization of synaptic potentials. Thus, rapid plasticity of PV intrinsic excitability implements network-level homeostasis to stabilize synaptic potentials in sensory cortex. Copyright © 2018 the authors.

  18. Cancellations of (helicopter-transported) mobile medical team dispatches in the Netherlands.

    PubMed

    Giannakopoulos, Georgios F; Lubbers, Wouter D; Christiaans, Herman M T; van Exter, Pieternel; Bet, Piet; Hugen, Paul J C; Innemee, Gerard; Schubert, Edo; de Lange-Klerk, Elly S M; Goslings, J Carel; Jukema, Gerrolt N

    2010-08-01

    The trauma centre of the Trauma Center Region North-West Netherlands (TRNWN) has consensus criteria for Mobile Medical Team (MMT) scene dispatch. The MMT can be dispatched by the EMS-dispatch centre or by the on-scene ambulance crew and is transported by helicopter or ground transport. Although much attention has been paid to improve the dispatch criteria, the MMT is often cancelled after being dispatched. The aim of this study was to assess the cancellation rate and the noncompliant dispatches of our MMT and to identify factors associated with this form of primary overtriage. By retrospective analysis of all MMT dispatches in the period from 1 July 2006 till 31 December 2006 using chart review, we conducted a consecutive case review of 605 dispatches. Four hundred and sixty seven of these were included for our study, collecting data related to prehospital triage, patient's condition on-scene and hospital course. Average age was 35.9 years; the majority of the patients were male (65.3%). Four hundred and thirty patients were victims of trauma, sustaining injuries in most cases from blunt trauma (89.3%). After being dispatched, the MMT was cancelled 203 times (43.5%). Statistically significant differences between assists and cancellations were found for overall mortality, mean RTS, GCS and ISS, mean hospitalization, length and amount of ICU admissions (p < 0.001). All dispatches were evaluated by using the MMT-dispatch criteria and mission appropriateness criteria. Almost 26% of all dispatches were neither appropriate, nor met the dispatch criteria. Fourteen missions were appropriate, but did not meet the dispatch criteria. The remaining 318 dispatches had met the dispatch criteria, of which 135 (30.3%) were also appropriate. The calculated additional costs of the cancelled dispatches summed up to a total of 34,448 euro, amounting to 2.2% of the total MMT costs during the study period. In our trauma system, the MMT dispatches are involved with high rates of overtriage. After being dispatched, the MMT is cancelled in almost 50% of all cases. We found an undertriage rate of 4%, which we think is acceptable. All cancellations were justified. The additional costs of the cancelled missions were within an acceptable range. According to this study, it seems to be possible to reduce the overtriage rate of the MMT dispatches, without increasing the undertriage rate to non-acceptable levels.

  19. Characterizing the effect of summer temperature on heatstroke-related emergency ambulance dispatches in the Kanto area of Japan

    NASA Astrophysics Data System (ADS)

    Ng, Chris Fook Sheng; Ueda, Kayo; Ono, Masaji; Nitta, Hiroshi; Takami, Akinori

    2014-07-01

    Despite rising concern on the impact of heat on human health, the risk of high summer temperature on heatstroke-related emergency dispatches is not well understood in Japan. A time-series study was conducted to examine the association between apparent temperature and daily heatstroke-related ambulance dispatches (HSAD) within the Kanto area of Japan. A total of 12,907 HSAD occurring from 2000 to 2009 in five major cities—Saitama, Chiba, Tokyo, Kawasaki, and Yokohama—were analyzed. Generalized additive models and zero-inflated Poisson regressions were used to estimate the effects of daily maximum three-hour apparent temperature (AT) on dispatch frequency from May to September, with adjustment for seasonality, long-term trend, weekends, and public holidays. Linear and non-linear exposure effects were considered. Effects on days when AT first exceeded its summer median were also investigated. City-specific estimates were combined using random effects meta-analyses. Exposure-response relationship was found to be fairly linear. Significant risk increase began from 21 °C with a combined relative risk (RR) of 1.22 (95 % confidence interval, 1.03-1.44), increasing to 1.49 (1.42-1.57) at peak AT. When linear exposure was assumed, combined RR was 1.43 (1.37-1.50) per degree Celsius increment. Overall association was significant the first few times when median AT was initially exceeded in a particular warm season. More than two-thirds of these initial hot days were in June, implying the harmful effect of initial warming as the season changed. Risk increase that began early at the fairly mild perceived temperature implies the need for early precaution.

  20. Characterizing the effect of summer temperature on heatstroke-related emergency ambulance dispatches in the Kanto area of Japan.

    PubMed

    Ng, Chris Fook Sheng; Ueda, Kayo; Ono, Masaji; Nitta, Hiroshi; Takami, Akinori

    2014-07-01

    Despite rising concern on the impact of heat on human health, the risk of high summer temperature on heatstroke-related emergency dispatches is not well understood in Japan. A time-series study was conducted to examine the association between apparent temperature and daily heatstroke-related ambulance dispatches (HSAD) within the Kanto area of Japan. A total of 12,907 HSAD occurring from 2000 to 2009 in five major cities-Saitama, Chiba, Tokyo, Kawasaki, and Yokohama-were analyzed. Generalized additive models and zero-inflated Poisson regressions were used to estimate the effects of daily maximum three-hour apparent temperature (AT) on dispatch frequency from May to September, with adjustment for seasonality, long-term trend, weekends, and public holidays. Linear and non-linear exposure effects were considered. Effects on days when AT first exceeded its summer median were also investigated. City-specific estimates were combined using random effects meta-analyses. Exposure-response relationship was found to be fairly linear. Significant risk increase began from 21 °C with a combined relative risk (RR) of 1.22 (95% confidence interval, 1.03-1.44), increasing to 1.49 (1.42-1.57) at peak AT. When linear exposure was assumed, combined RR was 1.43 (1.37-1.50) per degree Celsius increment. Overall association was significant the first few times when median AT was initially exceeded in a particular warm season. More than two-thirds of these initial hot days were in June, implying the harmful effect of initial warming as the season changed. Risk increase that began early at the fairly mild perceived temperature implies the need for early precaution.

  1. Bora-driven potential vorticity banners over the Adriatic

    NASA Astrophysics Data System (ADS)

    Grubii, Vanda

    2004-10-01

    A case study is presented of the secondary potential vorticity (PV) banners over the northern Adriatic that occurred in an early stage of a bora on 7 November 1999 during the Mesoscale Alpine Programme (MAP) Special Observation Period. The dynamics and structure of the lee-side and cross-mountain flow past the Dinaric Alps were investigated using data collected in a dual-aircraft (NCAR Electra and NOAA P-3) MAP Intensive Observing Period 15 mission over the Adriatic and high-resolution numerical simulations. The observational study employs flight-level, dropsonde, and Scanning Aerosol Backscatter Lidar data. The observed flow structure is compared with simulations results of the COAMPS model run at a horizontal resolution of 3 km. The Dinaric Alps, the north-west/south-east oriented coastal mountain range of Croatia, has an irregular ridge line with a number of peaks in the range of 1.5-2 km with several prominent mountain passes. The identified jet and wake structure within the east-north-easterly bora over the Adriatic was found to be well correlated with the upwind distribution of mountain passes and peaks. The wake flow structure was found also to be in excellent agreement with the climatological profile of the bora strength along the Croatian coast. The attendant secondary PV banners separating individual jets and wakes, diagnosed by computing PV from the flight-level data, were found to have a characteristic horizontal scale of 10-25 km, and a maximum amplitude of up to ~6 pvu within the boundary layer. Over the open sea, the thickness of the boundary layer, within which the east-north-easterly bora also achieved its maximum strength, was approximately 1 km. Detailed comparison with the numerical model results shows that, at the horizontal resolution of 3 km, the COAMPS model reproduces well the overall flow structure. The COAMPS-simulated PV field was found to be in good agreement with the PV derived from observations. The differences in substructure between simulated and experimentally derived PV profiles derive from minor differences between modelled and observed velocity and potential temperature profiles, which are subsequently accentuated by computing differentiated quantities such as vorticity and potential temperature gradients. The high predictability and steadiness of the PV banners, and a good correlation with the geometry of the upwind topography, support the orographic generation mechanism of PV with dissipation in hydraulic jumps and gravity-wave breaking regions as the likely main source of PV.

  2. The role of CSP in Brazil: A multi-model analysis

    NASA Astrophysics Data System (ADS)

    Soria, Rafael; Lucena, André F. P.; Tomaschek, Jan; Fichter, Tobias; Haasz, Thomas; Szklo, Alexandre; Schaeffer, Roberto; Rochedo, Pedro; Fahl, Ulrich; Kern, Jürgen; Hoffmann, Susanne

    2016-05-01

    MESSAGE, TIMES and REMIX-CEM are potential tools for modelling a larger penetration of variable renewable energy (VRE) into the Brazilian power system. They also allow devising the opportunities that concentrated solar power (CSP) plants offer to the power system and to the wider energy system. There are different opportunities for CSP in Brazil in the short and medium term, consolidating this technology as a feasible alternative for greenhouse gas (GHG) mitigation in Brazil. This work verified that CSP is a cost-effective option only under very stringent mitigation scenarios (4DS and 2DS) and when carbon capture and storage (CCS) is not available. Still, according to the findings of REMIX-CEM-B, CSP can provide firm energy and dispatchable capacity in the Northeast region of Brazil, optimally complementing wind and PV generation. Moreover, CSP can offer additional flexibility to the Northeast power system, especially during winter and after 2030.

  3. Forecasting of Hourly Photovoltaic Energy in Canarian Electrical System

    NASA Astrophysics Data System (ADS)

    Henriquez, D.; Castaño, C.; Nebot, R.; Piernavieja, G.; Rodriguez, A.

    2010-09-01

    The Canarian Archipelago face similar problems as most insular region lacking of endogenous conventional energy resources and not connected to continental electrical grids. A consequence of the "insular fact" is the existence of isolated electrical systems that are very difficult to interconnect due to the considerable sea depths between the islands. Currently, the Canary Islands have six isolated electrical systems, only one utility generating most of the electricity (burning fuel), a recently arrived TSO (REE) and still a low implementation of Renewable Energy Resources (RES). The low level of RES deployment is a consequence of two main facts: the weakness of the stand-alone grids (from 12 MW in El Hierro up to only 1 GW in Gran Canaria) and the lack of space to install RES systems (more than 50% of the land protected due to environmental reasons). To increase the penetration of renewable energy generation, like solar or wind energy, is necessary to develop tools to manage them. The penetration of non manageable sources into weak grids like the Canarian ones causes a big problem to the grid operator. There are currently 104 MW of PV connected to the islands grids (Dec. 2009) and additional 150 MW under licensing. This power presents a serious challenge for the operation and stability of the electrical system. ITC, together with the local TSO (Red Eléctrica de España, REE) started in 2008 and R&D project to develop a PV energy prediction tool for the six Canarian Insular electrical systems. The objective is to supply reliable information for hourly forecast of the generation dispatch programme and to predict daily solar radiation patterns, in order to help program spinning reserves. ITC has approached the task of weather forecasting using different numerical model (MM5 and WRF) in combination with MSG (Meteosat Second Generation) images. From the online data recorded at several monitored PV plants and meteorological stations, PV nominal power and energy produced by every plant in Canary Islands are estimated using a series of theoretical and statistical energy models.

  4. Effects of different excitation waveforms on detection and characterisation of delamination in PV modules by active infrared thermography

    NASA Astrophysics Data System (ADS)

    Sinha, Archana; Gupta, Rajesh

    2017-10-01

    Delamination significantly affects the performance and reliability of photovoltaic (PV) modules. Recently, an active infrared thermography approach using step heating has been exploited for the detection and characterisation of delamination in PV modules. However, step heating takes longer observation time and causes overheating problems. This paper presents the effects of different thermal excitation waveforms namely rectangular, half-sine and short pulse, on the detection and characterisation of delamination in PV module by experiments and simulations. For simulation, a 3-dimensional electro-thermal model of heat conduction, based on resistance-capacitance network approach, has been exploited to study the variation in maximum thermal contrast and peak contrast time with the delamination thickness and heating parameters. Results show that the rectangular waveform provides better detection of delamination due to higher absolute contrast, while the half-sine waveform allows better characterisation of delamination in the PV modules with low-cost and low-power heat source. The high-energy short pulse enabled quick visualisation of delamination, but has limited practical implementation. The advantages and limitations of each waveform have been highlighted to assess the specific requirement for appropriate choice in the non-destructive thermographic inspection of delamination in PV modules at the manufacturing units or outdoor fields.

  5. Nonlinear Dynamics and Bifurcation Analysis of a Boost Converter for Battery Charging in Photovoltaic Applications

    NASA Astrophysics Data System (ADS)

    Al-Hindawi, Mohammed M.; Abusorrah, Abdullah; Al-Turki, Yusuf; Giaouris, Damian; Mandal, Kuntal; Banerjee, Soumitro

    Photovoltaic (PV) systems with a battery back-up form an integral part of distributed generation systems and therefore have recently attracted a lot of interest. In this paper, we consider a system of charging a battery from a PV panel through a current mode controlled boost dc-dc converter. We analyze its complete nonlinear/nonsmooth dynamics, using a piecewise model of the converter and realistic nonlinear v-i characteristics of the PV panel. Through this study, it is revealed that system design without taking into account the nonsmooth dynamics of the converter combined with the nonlinear v-i characteristics of the PV panel can lead to unpredictable responses of the overall system with high current ripple and other undesirable phenomena. This analysis can lead to better designed converters that can operate under a wide variation of the solar irradiation and the battery's state of charge. We show that the v-i characteristics of the PV panel combined with the battery's output voltage variation can increase or decrease the converter's robustness, both under peak current mode control and average current mode control. We justify the observation in terms of the change in the discrete-time map caused by the nonlinear v-i characteristics of the PV panel. The theoretical results are validated experimentally.

  6. Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, Andrew; Wiser, Ryan

    2012-05-18

    We estimate the long-run economic value of variable renewable generation with increasing penetration using a unique investment and dispatch model that captures long-run investment decisions while also incorporating detailed operational constraints and hourly time resolution over a full year. High time resolution and the incorporation of operational constraints are important for estimating the economic value of variable generation, as is the use of a modeling framework that accommodates new investment decisions. The model is herein applied with a case study that is loosely based on California in 2030. Increasing amounts of wind, photovoltaics (PV), and concentrating solar power (CSP) with and without thermal energy storage (TES) are added one at a time. The marginal economic value of these renewable energy sources is estimated and then decomposed into capacity value, energy value, day-ahead forecast error cost, and ancillary services. The marginal economic value, as defined here, is primarily based on the combination of avoided capital investment cost and avoided variable fuel and operations and maintenance costs from other power plants in the power system. Though the model only captures a subset of the benefits and costs of renewable energy, it nonetheless provides unique insights into how the value of that subset changes with technology and penetration level. Specifically, in this case study implementation of the model, the marginal economic value of all three solar options is found to exceed the value of a flat-block of power (as well as wind energy) by \\more » $$20--30/MWh at low penetration levels, largely due to the high capacity value of solar at low penetration. Because the value of CSP per unit of energy is found to be high with or without thermal energy storage at low penetration, we find little apparent incremental value to thermal storage at low solar penetration in the present case study analysis. The marginal economic value of PV and CSP without thermal storage is found to drop considerably (by more than \\$$70/MWh) as the penetration of solar increases toward 30\\percent on an energy basis. This is due primarily to a steep drop in capacity value followed by a decrease in energy value. In contrast, the value of CSP with thermal storage drops much less dramatically as penetration increases. As a result, at solar penetration levels above 10\\percent, CSP with thermal storage is found to be considerably more valuable relative to PV and CSP without thermal storage. The marginal economic value of wind is found to be largely driven by energy value, and is lower than solar at low penetration. The marginal economic value of wind drops at a relatively slower rate with penetration, however. As a result, at high penetration, the value of wind can exceed the value of PV and CSP without thermal storage. Though some of these findings may be somewhat unique to the specific case study presented here, the results: (1) highlight the importance of an analysis framework that addresses long-term investment decisions as well as short-term dispatch and operational constraints, (2) can help inform long-term decisions about renewable energy procurement and supporting infrastructure, and (3) point to areas where further research is warranted.« less

  7. Temperature measurement during polymerization of bone cement in percutaneous vertebroplasty: an in vivo study in humans.

    PubMed

    Anselmetti, Giovanni Carlo; Manca, Antonio; Kanika, Khanna; Murphy, Kieran; Eminefendic, Haris; Masala, Salvatore; Regge, Daniele

    2009-05-01

    Aim of the study was to "in vivo" measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45 degrees C. After the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p < 0.05) in peak temperatures, variations between cements, and clinical outcome. All procedures were completed without complications, achieving good clinical outcomes (p < 0.0001). Regarding average peak temperature, cements were divided into three groups: A (over 60 degrees C), B (from 50 degrees to 60 degrees C), and C (below 50 degrees C). Peak temperature in Group A (86.7 +/- 10.7 degrees C) was significantly higher (p = 0.0172) than that in Groups B (60.5 +/- 3.7 degrees C) and C (44.8 +/- 2.6 degrees C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature >or=45 degrees C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.

  8. Temperature Measurement During Polymerization of Bone Cement in Percutaneous Vertebroplasty: An In Vivo Study in Humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anselmetti, Giovanni Carlo, E-mail: giovanni.anselmetti@ircc.it; Manca, Antonio; Kanika, Khanna

    2009-05-15

    Aim of the study was to 'in vivo' measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45{sup o}C. Aftermore » the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p < 0.05) in peak temperatures, variations between cements, and clinical outcome. All procedures were completed without complications, achieving good clinical outcomes (p < 0.0001). Regarding average peak temperature, cements were divided into three groups: A (over 60{sup o}C), B (from 50{sup o} to 60{sup o}C), and C (below 50{sup o}C). Peak temperature in Group A (86.7 {+-} 10.7{sup o}C) was significantly higher (p = 0.0172) than that in Groups B (60.5 {+-} 3.7{sup o}C) and C (44.8 {+-} 2.6{sup o}C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature {>=}45{sup o}C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.« less

  9. New pulmonary vein Doppler echocardiographic index predicts significant interatrial shunting in secundum atrial septal defect.

    PubMed

    Lam, Yat-Yin; Fang, Fang; Yip, Gabriel Wai-Kwok; Li, Zhi-An; Yang, Ya; Yu, Cheuk-Man

    2012-09-20

    The relation between pulmonary venous flow (PVF) pattern and degree of left-to-right interatrial shunting (IAS) in patients with secundum atrial septal defect (ASD) is unknown. Fifty consecutive ASD patients (14 males, 36 ± 17 years) received transthoracic echocardiography (TTE) before and 1 day after transcatheter closure and their results were compared to 40 controls. The ratio of pulmonary-to-systemic flows (Qp/Qs) was assessed by TTE and invasive oximetry. Pre-closure PV systolic (PVs), diastolic (PVd) velocities and velocity-time integral (PV-VTI) increased, time from onset of ECG Q-wave to the peak PV diastolic wave (Q-PVd) shortened and atrial reversal (PVar) velocity significantly decreased as compared to normals. These findings normalized after closure. Patients with large IAS (defined as invasive Qp/Qs ≥ 2) had higher PVs, PVd and PV-VTI, shorter Q-PVd but lower PVar (all p<0.01) than those with small IAS. Invasive Qp/Qs ratios correlated with PVs, PVd, PV-VTI, Q-PVd and TTE-derived Qp/Qs ratios, ASD sizes and RV end-diastolic dimensions (all p<0.05). PV-VTI (β=0.49) and ASD size (β=0.48) remained independent predictors of large IAS after multivariate analysis. The corresponding sensitivity, specificity and AUC were 89%, 82% and 0.90 respectively for a PV-VTI of 30 cm (p<0.001). ASD patients with significant IAS have distinguishable PVF features. Doppler evaluation of PV-VTI is a novel additional tool for assessing the magnitude of shunting in these patients non-invasively. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Analysis of InxGa1-xN/Si p-n heterojunction solar cells and the effects of spontaneous and piezoelectric polarization charges

    NASA Astrophysics Data System (ADS)

    Zheng, Yangdong; Mihara, Akihiro; Yamamoto, Akio

    2013-10-01

    The band structures, current-voltage characteristics under solar illumination, and photovoltaic (PV) properties of InxGa1-xN/Si p-n heterojunction solar cells (SCs), as well as the effects of spontaneous and piezoelectric polarization (Psp-PPZ) induced charges are investigated theoretically and numerically. We find that the energy peaks on the conduction and valence bands could exponentially reduce the diffusion currents and photocurrents, thus profoundly affect the PV properties of the SCs. Except for large values, the Psp-PPZ induced interface charges have little influence on the band structures and the PV properties. These results should be useful in analysis and design for multijunction tandem InxGa1-xN/Si SC devices.

  11. Relative Economic Merits of Storage and Combustion Turbines for Meeting Peak Capacity Requirements under Increased Penetration of Solar Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denholm, Paul; Diakov, Victor; Margolis, Robert

    Batteries with several hours of capacity provide an alternative to combustion turbines for meeting peak capacity requirements. Even when compared to state-of-the-art highly flexible combustion turbines, batteries can provide a greater operational value, which is reflected in a lower system-wide production cost. By shifting load and providing operating reserves, batteries can reduce the cost of operating the power system to a traditional electric utility. This added value means that, depending on battery life, batteries can have a higher cost than a combustion turbine of equal capacity and still produce a system with equal or lower overall life-cycle cost. For amore » utility considering investing in new capacity, the cost premium for batteries is highly sensitive to a variety of factors, including lifetime, natural gas costs, PV penetration, and grid generation mix. In addition, as PV penetration increases, the net electricity demand profile changes, which may reduce the amount of battery energy capacity needed to reliably meet peak demand.« less

  12. New Markets for Solar Photovoltaic Power Systems

    NASA Astrophysics Data System (ADS)

    Thomas, Chacko; Jennings, Philip; Singh, Dilawar

    2007-10-01

    Over the past five years solar photovoltaic (PV) power supply systems have matured and are now being deployed on a much larger scale. The traditional small-scale remote area power supply systems are still important and village electrification is also a large and growing market but large scale, grid-connected systems and building integrated systems are now being deployed in many countries. This growth has been aided by imaginative government policies in several countries and the overall result is a growth rate of over 40% per annum in the sales of PV systems. Optimistic forecasts are being made about the future of PV power as a major source of sustainable energy. Plans are now being formulated by the IEA for very large-scale PV installations of more than 100 MW peak output. The Australian Government has announced a subsidy for a large solar photovoltaic power station of 154 MW in Victoria, based on the concentrator technology developed in Australia. In Western Australia a proposal has been submitted to the State Government for a 2 MW photovoltaic power system to provide fringe of grid support at Perenjori. This paper outlines the technologies, designs, management and policies that underpin these exciting developments in solar PV power.

  13. Error analysis of the Golay3 optical imaging system.

    PubMed

    Wu, Quanying; Fan, Junliu; Wu, Feng; Zhao, Jun; Qian, Lin

    2013-05-01

    We use aberration theory to derive a generalized pupil function of the Golay3 imaging system when astigmatisms exist in its submirrors. Theoretical analysis and numerical simulation using ZEMAX show that the point spread function (PSF) and the modulation transfer function (MTF) of the Golay3 sparse aperture system have a periodic change when there are piston errors. When the peak-valley value of the wavefront (PV(tilt)) due to the tilt error increases from zero to λ, the PSF and the MTF change significantly, and the change direction is determined by the location of the submirror with the tilt error. When PV(tilt) becomes larger than λ, the PSF and the MTF remain unvaried. We calculate the peaks of the signal-to-noise ratio (PSNR) resulting from the piston and tilt errors according to the Strehl ratio, and show that the PSNR decreases when the errors increase.

  14. Influence of orbital eye position on vertical saccades in progressive supranuclear palsy

    PubMed Central

    Schneider, Rosalyn; Chen, Athena L.; King, Susan A.; Riley, David E.; Gunzler, Steven A.; Devereaux, Michael. W.; Leigh, R. John

    2011-01-01

    Disturbance of vertical saccadesis a cardinal feature of progressive supranuclear palsy (PSP). We investigated whether the amplitude and peak velocity of saccades is affected by the orbital position fromwhich movements start in PSP patients and age-matched control subjects. Subjects made vertical saccades in response to ± 5 degree vertical target jumps with their heads in one of three positions: head “center,” head pitched forward ~15 degrees, and head pitched back ~ 15 degrees.All patients showed some effect of starting eye position, whether beginning in the upward or downward field of gaze, on saccade amplitude, peak velocity (PV), and net range of movement. Generally, reduction of amplitude and PV were commensurate and bidirectional in the affected hemifield of gaze. Such findings are unlikelyto be due to orbital factors and could be explained by varying degrees of involvement of rostral midbrain nucleiin the pathological process. PMID:21950977

  15. Measurement of inflight shell areal density near peak velocity using a self backlighting technique

    NASA Astrophysics Data System (ADS)

    Pickworth, L. A.; Hammel, B. A.; Smalyuk, V. A.; MacPhee, A. G.; Scott, H. A.; Robey, H. F.; Landen, O. L.; Barrios, M. A.; Regan, S. P.; Schneider, M. B.; Hoppe, M., Jr.; Kohut, T.; Holunga, D.; Walters, C.; Haid, B.; Dayton, M.

    2016-05-01

    The growth of perturbations in inertial confinement fusion (ICF) capsules can lead to significant variation of inflight shell areal density (ρR), ultimately resulting in poor compression and ablator material mixing into the hotspot. As the capsule is accelerated inward, the perturbation growth results from the initial shock-transit through the shell and then amplification by Rayleigh-Taylor as the shell accelerates inwards. Measurements of ρR perturbations near peak implosion velocity (PV) are essential to our understanding of ICF implosions because they reflect the integrity of the capsule, after the inward acceleration growth is complete, of the actual shell perturbations including native capsule surface roughness and “isolated defects”. Quantitative measurements of shell-ρR perturbations in capsules near PV are challenging, requiring a new method with which to radiograph the shell. An innovative method, utilized in this paper, is to use the self-emission from the hotspot to “self- backlight” the shell inflight. However, with nominal capsule fills there is insufficient self-emission for this method until the capsule nears peak compression (PC). We produce a sufficiently bright continuum self-emission backlighter through the addition of a high-Z gas (∼ 1% Ar) to the capsule fill. This provides a significant (∼10x) increase in emission at hυ∼8 keV over nominal fills. “Self backlit” radiographs are obtained for times when the shock is rebounding from the capsule center, expanding out to meet the incoming shell, providing a means to sample the capsule optical density though only one side, as it converges through PV.

  16. [Dispatchers' impressions and actual quality of cardiopulmonary resuscitation during telephone-assisted bystander cardiopulmonary resuscitation: a pooled analysis of 94 simulated, manikin-based scenarios].

    PubMed

    van Tulder, Raphael; Roth, Dominik; Laggner, Roberta; Krammel, Mario; Schriefl, Christoph; Kienbacher, Calvin; Novosad, Heinz; Chwojka, Constantin Christof; Sterz, Fritz; Havel, Christof; Schreiber, Wolfgang; Herkner, Harald

    2017-02-01

    The quality of telephone-assisted cardiopulmonary resuscitation (CPR) needs improvement. This study investigates whether a dispatchers' perception is an adequate measure of the actual quality of CPR provided by laypersons. Individual participant data from 3 randomized simulation trials, with identical methodology but different interventions, were combined for this analysis. Professional dispatchers gave telephone assistance to laypersons, who each provided 10 minutes of CPR on a manikin. Dispatchers were requested to classify the quality of providers' CPR as adequate or inadequate. Based on actual readings from manikins we classified providers' performance as adequate at 5-6 cm for depth and 100-120 compressions per minute (cpm) for rate. We calculated metrics of dispatcher accuracy. Six dispatchers rated the performance of 94 laypersons (38 women [42%]) with a mean (SD) age of 37 (14) years. In 905 analyzed minutes of telephone-assisted CPR, the mean compression depth and rate was 41 (13) mm and 98 (24) cpm, respectively. Analysis of dispatchers' diagnostic test accuracy for adequate compression depth yielded a sensitivity of 65% (95 CI 36%-95%) and specificity of 42% (95% CI, 32%-53%). Analysis of their assessment of adequate compression rate yielded a sensitivity of 75% (95% CI, 64%-86%) and specificity of 42% (95% CI, 32%-52%). Although dispatchers always underestimated the actual values of CPR parameters, the female dispatchers evaluations were less inaccurate than the evaluations of make dispatchers; the dispatchers overall (males and females together) underestimated the adequacy of female laypersons' CPR performance to a greater degree than female dispatchers did. The ability of dispatchers to estimate the quality of telephone-assisted CPR is limited. Dispatchers estimates of CPR adequacy needs to be studied further in order to find ways that telephone-assisted CPR might be improved.

  17. Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method

    DOE PAGES

    Lu, Ping; Moya, Jaime M.; Yuan, Renliang; ...

    2018-03-01

    The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maximamore » (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K+L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. In conclusion, with increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping.« less

  18. Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Ping; Moya, Jaime M.; Yuan, Renliang

    The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maximamore » (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K+L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. In conclusion, with increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping.« less

  19. Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method.

    PubMed

    Lu, Ping; Moya, Jaime M; Yuan, Renliang; Zuo, Jian Min

    2018-03-01

    The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maxima (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K + L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. With increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping. Published by Elsevier B.V.

  20. The Mathematics of Dispatchability, Revisited

    NASA Technical Reports Server (NTRS)

    Morris, Paul

    2016-01-01

    Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently, it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, dispatchability has considerable theoretical as well as practical significance. One thing that hampers further work in this area is the underdeveloped theory. Moreover, the existing foundation is inadequate in certain respects. In this paper, we develop a new mathematical theory of dispatchability and its relationship to execution. We also provide several characterizations of dispatchability, including characterizations in terms of the structural properties of the STN graph. This facilitates the potential application of the theory to other areas.

  1. The Mathematics of Dispatchability Revisited

    NASA Technical Reports Server (NTRS)

    Morris, Paul

    2016-01-01

    Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, the dispatchability property has both theoretical and practical interest. One thing that hampers further work in this area is the underdeveloped theory. The existing definitions are expressed in terms of algorithms, and are less suitable for mathematical proofs. In this paper, we develop a new formal theory of dispatchability in terms of execution sequences. We exploit this to prove a characterization of dispatchability involving the structural properties of the STN graph. This facilitates the potential application of the theory to uncertainty reasoning.

  2. Electrocardiographic findings in patients with polycythemia vera.

    PubMed

    Kayrak, Mehmet; Acar, Kadir; Gul, Enes Elvin; Abdulhalikov, Turyan; Bağlıcaklıoğlu, Murat; Sonmez, Osman; Kaya, Zeynettin; Arı, Hatem

    2012-01-01

    The 12-lead surface electrocardiogram (ECG) is a useful tool to predict both atrial and ventricular arrhythmias via P-wave and QT measurements and its derivatives. Polycythemia vera (PV) is a chronic myeloproliferative disorder associated with cardiovascular events. The aim of this study was to assess ECG findings of patients with PV. Sixty patients with PV (34 male, mean age 58±11 years) and 60 age and gender-matched healthy volunteers were enrolled into the study. From the 12-lead surface ECG, P-wave and both conventional QT measurements and transmyocardial repolarization parameters (T(peak)-T(end) interval (T(p)-T(e)) and derivatives) were evaluated digitally by two experienced cardiologists. In addition, a novel parameter, Pi was calculated digitally as the standard deviation of the P-wave duration across the 12 ECG leads. QT duration and corrected QT interval were significantly longer in the PV group compared to healthy controls (p<0.01 and p<0.01, respectively). The T(p)-T(e) was longer and the T(p)-T(e)/QT ratio was significantly higher in the PV group compared to the controls. P-wave analyses showed that all P-wave parameters including Pmax, Pmin, P dispersion, and Pi were significantly prolonged in PV patients compared to the controls. The increase of both T(p)-T(e )and P max in the PV group was independent of age, BMI, diabetes and hypertension, gender, systolic blood pressure, hemoglobin, hematocrit, left atrial dimension, left ventricular end-diastolic diameter and early deceleration time in a univariate analysis of co-variance model (F=11.097, p=0.001 and F=31.537, p=0.0001, respectively). The present study demonstrated that PV may be associated with electrocardiographic abnormalities of both atrium and ventricle.

  3. Analysis on Dissemination Conditions of Photovoltaics in Japan by Using Energy System Model MARKAL

    NASA Astrophysics Data System (ADS)

    Endo, Eiichi; Ichinohe, Masayuki

    The national target for PV capacity in Japan is 4. 82, GW in 2010, and several PV Roadmaps until 2030 are also described. To achieve the target, several support programs, such as subsidization to capital cost, Green Credit by the Green Power Certification System, buy-back under the Renewable Portfolio Standard low, have been already introduced. Carbon tax is still under consideration, but there are several analyses about possible carbon tax. The purpose of this paper is to analyze PV system sales price and subsidy through buy-back which make photovoltaics cost-competitive with other energy technologies and make the target for PV capacity achievable by 2030 in Japan under an expected carbon tax. For the analysis energy system of Japan is modeled by using MARKAL. Based on the results of analysis, under 6000, JPY/t-C carbon tax, photovoltaics needs subsidy for a while even if we taking both fuel savings and Green Credit into account. For attaining the national target for PV capacity in 2010, photovoltaics needs more expensive buy-back than that in present, but after 2010 necessary buy-back decreases gradually. If 120, JPY/W PV system sales price is attained by 2030, photovoltaics becomes cost-competitive without any supports. Subsidy through buy-back becomes almost unnecessary in 2030, if we can reduce it less than 170, JPY/W. The total necessary buy-back meets peak in 2025. It is much more than ongoing subsidy to capital cost of PV systems, but annual revenue from the assumed carbon tax can finance the annual total necessary buy-back. This means if photovoltaics can attain the targeted PV system sales price, we should support it for a while by spending carbon tax revenue effectively and efficiently.

  4. Generation and Use of Thermal Energy in the Industrial Sector and Opportunities to Reduce its Carbon Emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMillan, Colin; Boardman, Richard; McKellar, Michael

    Changes are occurring throughout the U.S. economy, especially in regard to how energy is generated and used in the electricity, buildings, industrial, and transportation sectors. These changes are being driven by environmental and energy security concerns and by economics. The electric-sector market share of natural gas and variable renewable generation, such as wind and solar photovoltaics (PV), continues to grow. The buildings sector is evolving to meet efficiency standards, the transportation sector is evolving to meet efficiency and renewable fuels standards, and the industrial sector is evolving to reduce emissions. Those changes are driving investment and utilization strategies for generationmore » and other assets. Nuclear and renewable energy sources are important to consider in the energy sector’s evolution because both are considered to be clean and non-carbon-emitting energy sources. The Idaho National Laboratory (INL) and the National Renewable Energy Laboratory (NREL) are jointly investigating potential synergies between technologies exploiting nuclear and renewable energy sources. The two laboratories have held several joint workshops since 2011. Those workshops brought together experts in both areas to identify synergies and potential opportunities to work together. Workshop participants identified nuclear-renewable hybrid energy systems (N-R HESs) as one of the opportunities and recommended investigating whether N-R HESs could both generate dispatchable electricity without carbon emissions and provide clean energy to industrial processes. They also recommended analyzing the potential for N-R HESs to provide dispatchable capacity to a grid with high penetrations of non-dispatchable resources and to investigate whether real inertia provided by thermal power cycles within N-R HESs provides value to the grid. This report is one of a series of reports INL and NREL are producing to investigate the technical and economic aspects of N-R HESs. Previous reports focused on tightly coupled N-R HESs. Previously, INL analyzed the dynamic performance of two hypothetical N-R HESs and NREL analyzed the optimal economic configurations and operation of the same two N-R HESs. The first of those two is a Texas-synthetic gasoline scenario that includes four subsystems: a nuclear reactor, thermal power cycle, wind power plant, and synthetic gasoline production technology. The second hypothetical N-R HES is an Arizona-desalination scenario with four subsystems: a nuclear reactor, thermal power cycle, PV, and a desalination plant. INL analyzed the technical performance of the same two N-R HESs in another report. In another report NREL used the Texas-synthetic gasoline scenario provides the basis; however, the industrial process was removed. Instead, that N-R HES sells heat directly to an industrial customer. Subsystems that convert electricity to heat were also included. Future analyses are planned for other N-R HES options including one where hydrogen is produced within an N-R HES. This report quantifies greenhouse gas (GHG) emissions from the industrial sector and identifies opportunities for non-GHG-emitting thermal energy sources, such as N-R HESs, to replace the most significant GHG-emitting U.S. industries based on targeted, process-level analysis of industrial heat requirements.« less

  5. Least cost pathways to a low carbon electricity system for Australia: impacts of transmission augmentation and extension

    NASA Astrophysics Data System (ADS)

    Dargaville, R. J.

    2016-12-01

    Designing the pathway to a low carbon energy system is complex, requiring consideration of the variable nature of renewables at the hourly timescale, emission intensity and ramp rate constraints of dispatchable technologies (both fossil and renewable) and transmission and distribution network limitations. In this work, an optimization framework taking into account these considerations has been applied to find the lowest cost ways to reduce carbon emissions by either 80% or 100% in 2050 while keeping the system operating reliably along the way. Technologies included are existing and advanced coal and gas technologies (with and without carbon capture and storage), rooftop PV, utility scale PV, concentrating solar thermal, hydro with and without pumped storage, bioenergy, and nuclear. In this study we also also the optimisation to increase transmission capacity along existing lines, and to extend key trunk lines into currently unserved areas. These augementations and extensions come at a cost. The otpimisation chooses these options when the benefits of accessing high quality renewable energy resources outweights the costs. Results show that for the 80% emission reduction case, there is limited need for transmission capacity increase, and that the existing grid copes well with the increased flows due to conversion to distrubuted renewable energy resources. However, in the 100% case the increased reliance on renewables means that signficant transmission augmentation is beneficial to the overall cost. This strongly suggests that it is important to understand the long term emission target early so that infrastructure investments can be optimised.

  6. Study on reasonable curtailment rate of large scale renewable energy

    NASA Astrophysics Data System (ADS)

    Li, Nan; Yuan, Bo; Zhang, Fuqiang

    2018-02-01

    Energy curtailment rate of renewable energy generation is an important indicator to measure renewable energy consumption, it is also an important parameters to determine the other power sources and grids arrangement in the planning stage. In general, to consume the spike power of the renewable energy which is just a small proportion, it is necessary to dispatch a large number of peaking resources, which will reduce the safety and stability of the system. In planning aspect, if it is allowed to give up a certain amount of renewable energy, overall peaking demand of the system will be reduced, the peak power supply construction can be put off to avoid the expensive cost of marginal absorption. In this paper, we introduce the reasonable energy curtailment rate into the power system planning, and use the GESP power planning software, conclude that the reasonable energy curtailment rate of the regional grids in China is 3% -10% in 2020.

  7. A Statistical Analysis of the Economic Drivers of Battery Energy Storage in Commercial Buildings: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Matthew; Simpkins, Travis; Cutler, Dylan

    There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape ofmore » the load profile is the most significant predictor of the size of the battery.« less

  8. A Statistical Analysis of the Economic Drivers of Battery Energy Storage in Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Matthew; Simpkins, Travis; Cutler, Dylan

    There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape ofmore » the load profile is the most significant predictor of the size of the battery.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darghouth, Naïm R.; Wiser, Ryan; Barbose, Galen

    The substantial increase in deployment of customer-sited solar photovoltaics (PV) in the United States has been driven by a combination of steeply declining costs, financing innovations, and supportive policies. Among those supportive policies is net metering, which in most states effectively allows customers to receive compensation for distributed PV generation at the full retail electricity price. The current design of retail electricity rates and the presence of net metering have elicited concerns that the possible under-recovery of fixed utility costs from PV system owners may lead to a feedback loop of increasing retail prices that accelerate PV adoption and furthermore » rate increases. However, a separate and opposing feedback loop could offset this effect: increased PV deployment may lead to a shift in the timing of peak-period electricity prices that could reduce the bill savings received under net metering where time-varying retail electricity rates are used, thereby dampening further PV adoption. In this paper, we examine the impacts of these two competing feedback dynamics on U.S. distributed PV deployment through 2050 for both residential and commercial customers, across states. Our results indicate that, at the aggregate national level, the two feedback effects nearly offset one another and therefore produce a modest net effect, although their magnitude and direction vary by customer segment and by state. We also model aggregate PV deployment trends under various rate designs and net-metering rules, accounting for feedback dynamics. Our results demonstrate that future adoption of distributed PV is highly sensitive to retail rate structures. Whereas flat, time-invariant rates with net metering lead to higher aggregate national deployment levels than the current mix of rate structures (+5% in 2050), rate structures with higher monthly fixed customer charges or PV compensation at levels lower than the full retail rate can dramatically erode aggregate customer adoption of PV (from -14% to -61%, depending on the design). Moving towards time-varying rates, on the other hand, may accelerate near- and medium-term deployment (through 2030), but is found to slow adoption in the longer term (-22% in 2050).« less

  10. Grid-Tied Photovoltaic Power System

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.

    2011-01-01

    A grid-tied photovoltaic (PV) power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. Operating costs of a PV power system are low compared to conventional power technologies. This method can displace the highest-cost electricity during times of peak demand in most climatic regions, and thus reduce grid loading. Net metering is often used, in which independent power producers such as PV power systems are connected to the utility grid via the customers main service panels and meters. When the PV power system is generating more power than required at that location, the excess power is provided to the utility grid. The customer pays the net of the power purchased when the on-site power demand is greater than the onsite power production, and the excess power is returned to the utility grid. Power generated by the PV system reduces utility demand, and the surplus power aids the community. Modern PV panels are readily available, reliable, efficient, and economical, with a life expectancy of at least 25 years. Modern electronics have been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy equal to the modern PV panels. The grid-tied PV power system was successfully designed and developed, and this served to validate the basic principles developed, and the theoretical work that was performed. Grid-tied PV power systems are reliable, maintenance- free, long-life power systems, and are of significant value to NASA and the community. Of particular value are the analytical tools and capabilities that have been successfully developed. Performance predictions can be made confidently for grid-tied PV systems of various scales. The work was done under the NASA Hybrid Power Management (HPM) Program, which is the integration of diverse power devices in an optimal configuration for space and terrestrial applications.

  11. In vitro C3 mRNA expression in Pemphigus vulgaris: complement activation is increased by IL-1alpha and TNF-alpha.

    PubMed

    Feliciani, C; Toto, P; Amerio, P

    1999-01-01

    Pemphigus vulgaris (PV) is a potentially life-threatening disease, characterized immunohistologically by IgG deposits and complement activation on the surface of keratinocytes. Complement activation has been implicated in the pathogenesis with C3 deposits in about 90% of patients. In order to further elucidate the role of complement in PV and to define which cytokines play a role in C3 mRNA expression, we performed an in vitro study in human keratinocytes. Normal human epidermal keratinocytes (NHuK) were incubated with PV serum and C3 mRNA was measured. We previously had shown that IL-1alpha and TNF-alpha are expressed in PV in vivo and in vitro. Since cytokines are able to modulate complement activation, mRNA expression was evaluated in a similar experiment after pretreatment using antibodies against IL-1alpha and TNF-alpha. Incubation of NHuK with PV sera caused their detachment from the plates after 20-30 minutes with a complete acantholysis within 12 hours. An early C3 mRNA expression was seen after 30 minutes with a peak level after 1 hour. Blocking studies, using antibodies against human IL-1alpha and TNF-alpha in NHuK together with PV-IgG, showed reduction of in vitro induced acantholysis and inhibition of C3 mRNA expression. This study supports the hypothesis that complement C3 is important in PV acantholysis and that complement activation is increased by IL-1alpha and TNF-alpha.

  12. Population variability complicates the accurate detection of climate change responses.

    PubMed

    McCain, Christy; Szewczyk, Tim; Bracy Knight, Kevin

    2016-06-01

    The rush to assess species' responses to anthropogenic climate change (CC) has underestimated the importance of interannual population variability (PV). Researchers assume sampling rigor alone will lead to an accurate detection of response regardless of the underlying population fluctuations of the species under consideration. Using population simulations across a realistic, empirically based gradient in PV, we show that moderate to high PV can lead to opposite and biased conclusions about CC responses. Between pre- and post-CC sampling bouts of modeled populations as in resurvey studies, there is: (i) A 50% probability of erroneously detecting the opposite trend in population abundance change and nearly zero probability of detecting no change. (ii) Across multiple years of sampling, it is nearly impossible to accurately detect any directional shift in population sizes with even moderate PV. (iii) There is up to 50% probability of detecting a population extirpation when the species is present, but in very low natural abundances. (iv) Under scenarios of moderate to high PV across a species' range or at the range edges, there is a bias toward erroneous detection of range shifts or contractions. Essentially, the frequency and magnitude of population peaks and troughs greatly impact the accuracy of our CC response measurements. Species with moderate to high PV (many small vertebrates, invertebrates, and annual plants) may be inaccurate 'canaries in the coal mine' for CC without pertinent demographic analyses and additional repeat sampling. Variation in PV may explain some idiosyncrasies in CC responses detected so far and urgently needs more careful consideration in design and analysis of CC responses. © 2016 John Wiley & Sons Ltd.

  13. Quasi-static time-series simulation using OpenDSS in IEEE distribution feeder model with high PV penetration and its impact on solar forecasting

    NASA Astrophysics Data System (ADS)

    Mohammed, Touseef Ahmed Faisal

    Since 2000, renewable electricity installations in the United States (excluding hydropower) have more than tripled. Renewable electricity has grown at a compounded annual average of nearly 14% per year from 2000-2010. Wind, Concentrated Solar Power (CSP) and solar Photo Voltaic (PV) are the fastest growing renewable energy sectors. In 2010 in the U.S., solar PV grew over 71% and CSP grew by 18% from the previous year. Globally renewable electricity installations have more than quadrupled from 2000-2010. Solar PV generation grew by a factor of more than 28 between 2000 and 2010. The amount of CSP and solar PV installations are increasing on the distribution grid. These PV installations transmit electrical current from the load centers to the generating stations. But the transmission and distribution grid have been designed for uni-directional flow of electrical energy from generating stations to load centers. This causes imbalances in voltage and switchgear of the electrical circuitry. With the continuous rise in PV installations, analysis of voltage profile and penetration levels remain an active area of research. Standard distributed photovoltaic (PV) generators represented in simulation studies do not reflect the exact location and variability properties such as distance between interconnection points to substations, voltage regulators, solar irradiance and other environmental factors. Quasi-Static simulations assist in peak load planning hour and day ahead as it gives a time sequence analysis to help in generation allocation. Simulation models can be daily, hourly or yearly depending on duty cycle and dynamics of the system. High penetration of PV into the power grid changes the voltage profile and power flow dynamically in the distribution circuits due to the inherent variability of PV. There are a number of modeling and simulations tools available for the study of such high penetration PV scenarios. This thesis will specifically utilize OpenDSS, a open source Distribution System Simulator developed by Electric Power Research Institute, to simulate grid voltage profile with a large scale PV system under quasi-static time series considering variations of PV output in seconds, minutes, and the average daily load variations. A 13 bus IEEE distribution feeder model is utilized with distributed residential and commercial scale PV at different buses for simulation studies. Time series simulations are discussed for various modes of operation considering dynamic PV penetration at different time periods in a day. In addition, this thesis demonstrates simulations taking into account the presence of moving cloud for solar forecasting studies.

  14. 14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...

  15. 14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...

  16. 14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...

  17. 14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...

  18. 14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...

  19. Direct electrochemistry of Shewanella loihica PV-4 on gold nanoparticles-modified boron-doped diamond electrodes fabricated by layer-by-layer technique.

    PubMed

    Wu, Wenguo; Xie, Ronggang; Bai, Linling; Tang, Zuming; Gu, Zhongze

    2012-05-01

    Microbial Fuel Cells (MFCs) are robust devices capable of taping biological energy, converting pollutants into electricity through renewable biomass. The fabrication of nanostructured electrodes with good bio- and electrochemical activity, play a profound role in promoting power generation of MFCs. Au nanoparticles (AuNPs)-modified Boron-Doped Diamond (BDD) electrodes are fabricated by layer-by-layer (LBL) self-assembly technique and used for the direct electrochemistry of Shewanella loihica PV-4 in an electrochemical cell. Experimental results show that the peak current densities generated on the Au/PAH multilayer-modified BDD electrodes increased from 1.25 to 2.93 microA/cm(-2) as the layer increased from 0 to 6. Different cell morphologies of S. loihica PV-4 were also observed on the electrodes and the highest density of cells was attached on the (Au/PAH)6/BDD electrode with well-formed three-dimensional nanostructure. The electrochemistry of S. loihica PV-4 was enhanced on the (Au/PAH)4/BDD electrode due to the appropriate amount of AuNPsand thickness of PAH layer.

  20. Impacts of temperature change on ambulance dispatches and seasonal effect modification.

    PubMed

    Cheng, Jian; Xu, Zhiwei; Zhao, Desheng; Xie, Mingyu; Yang, Huihui; Wen, Liying; Li, Kesheng; Su, Hong

    2016-12-01

    Ambulance dispatch is a proxy of acute health outcomes, and growing epidemiological evidence documented its relation to extreme temperature events. Research, however, on short-term temperature change and ambulance dispatches is scarce. We aimed to investigate the effect of short-term temperature change on ambulance dispatches and potential modification by season. Daily data on ambulance dispatch and weather factors were collected in Huainan, a Chinese inland city from December 2011 through December 2013. A Poison generalized linear regression model combined with distributed lag nonlinear model was constructed to examine the association of temperature change between neighboring days (TCN) with ambulance dispatches. The effect modification by season was also examined. There were 48,700 ambulance attendances during the study period. A statistically significant association of TCN with ambulance dispatches was observed. Temperature rise between neighboring days (TCN > 0) was associated with elevated adverse risk of ambulance dispatches, and the effects appeared to be acute (lag0, on the current day) and could last for at least a week, while temperature drop between neighboring days (TCN < 0) had a protective effect. For a 1 °C increase of TCN at lag0 and lag06 (on the 7-day moving average), the risk of ambulance dispatches increased by 2 % (95 % CI 1-3 %) and 7 (95 % CI 1-13 %), respectively. Extreme TCN increase (95th percentile, 3.3 °C vs. 0 °C) at lag0 and lag05 was accompanied by 6 (95 % CI 3-8 %) and 27 % (95 % CI 12-44 %) increase in ambulance dispatches. Ambulance dispatches were more vulnerable to extremely great temperature rise in summer and autumn. TCN was adopted for the first time to quantify the impact of short-term temperature change on ambulance dispatches. Temperature drop between neighboring days (TCN < 0) had a protective effect on ambulance dispatches, while temperature rise between neighboring days (TCN > 0) could acutely trigger the increase in ambulance dispatches, and TCN effect differs by season.

  1. Sustainable electricity generation by solar pv/diesel hybrid system without storage for off grids areas

    NASA Astrophysics Data System (ADS)

    Azoumah, Y.; Yamegueu, D.; Py, X.

    2012-02-01

    Access to energy is known as a key issue for poverty reduction. The electrification rate of sub Saharan countries is one of the lowest among the developing countries. However this part of the world has natural energy resources that could help raising its access to energy, then its economic development. An original "flexy energy" concept of hybrid solar pv/diesel/biofuel power plant, without battery storage, is developed in order to not only make access to energy possible for rural and peri-urban populations in Africa (by reducing the electricity generation cost) but also to make the electricity production sustainable in these areas. Some experimental results conducted on this concept prototype show that the sizing of a pv/diesel hybrid system by taking into account the solar radiation and the load/demand profile of a typical area may lead the diesel generator to operate near its optimal point (70-90 % of its nominal power). Results also show that for a reliability of a PV/diesel hybrid system, the rated power of the diesel generator should be equal to the peak load. By the way, it has been verified through this study that the functioning of a pv/Diesel hybrid system is efficient for higher load and higher solar radiation.

  2. Dispatcher Recognition of Stroke Using the National Academy Medical Priority Dispatch System

    PubMed Central

    Buck, Brian H; Starkman, Sidney; Eckstein, Marc; Kidwell, Chelsea S; Haines, Jill; Huang, Rainy; Colby, Daniel; Saver, Jeffrey L

    2009-01-01

    Background Emergency Medical Dispatchers (EMDs) play an important role in optimizing stroke care if they are able to accurately identify calls regarding acute cerebrovascular disease. This study was undertaken to assess the diagnostic accuracy of the current national protocol guiding dispatcher questioning of 911 callers to identify stroke, QA Guide v 11.1 of the National Academy Medical Priority Dispatch System (MPDS). Methods We identified all Los Angeles Fire Department paramedic transports of patients to UCLA Medical Center during the 12 month period from January to December 2005 in a prospectively maintained database. Dispatcher-assigned MPDS codes for each of these patient transports were abstracted from the paramedic run sheets and compared to final hospital discharge diagnosis. Results Among 3474 transported patients, 96 (2.8%) had a final diagnosis of stroke or transient ischemic attack. Dispatchers assigned a code of potential stroke to 44.8% of patients with a final discharge diagnosis of stroke or TIA. Dispatcher identification of stroke showed a sensitivity of 0.41, specificity of 0.96, positive predictive value of 0.45, and negative predictive value of 0.95. Conclusions Dispatcher recognition of stroke calls using the widely employed MPDS algorithm is suboptimal, with failure to identify more than half of stroke patients as likely stroke. Revisions to the current national dispatcher structured interview and complaint identification algorithm for stroke may facilitate more accurate recognition of stroke by EMDs. PMID:19390065

  3. A Hybrid Multilevel Storage Architecture for Electric Power Dispatching Big Data

    NASA Astrophysics Data System (ADS)

    Yan, Hu; Huang, Bibin; Hong, Bowen; Hu, Jing

    2017-10-01

    Electric power dispatching is the center of the whole power system. In the long run time, the power dispatching center has accumulated a large amount of data. These data are now stored in different power professional systems and form lots of information isolated islands. Integrating these data and do comprehensive analysis can greatly improve the intelligent level of power dispatching. In this paper, a hybrid multilevel storage architecture for electrical power dispatching big data is proposed. It introduces relational database and NoSQL database to establish a power grid panoramic data center, effectively meet power dispatching big data storage needs, including the unified storage of structured and unstructured data fast access of massive real-time data, data version management and so on. It can be solid foundation for follow-up depth analysis of power dispatching big data.

  4. Differentiation in MALDI-TOF MS and FTIR spectra between two pathovars of Xanthomonas oryzae

    NASA Astrophysics Data System (ADS)

    Ge, Mengyu; Li, Bin; Wang, Li; Tao, Zhongyun; Mao, Shengfeng; Wang, Yangli; Xie, Guanlin; Sun, Guochang

    2014-12-01

    Xanthomonas oryzae pv. oryzae (Xoo) and Xanthomonas oryzae pv. oryzicola (Xoc) strains are closely related phenotypically and genetically, which make it difficult to differentiate between the two pathovars based on phenotypic and DNA-based methods. In this study, a fast and accurate method was developed based on the differences in MALDI-TOF MS and FTIR spectra between the two pathovars. MALDI-TOF MS analysis revealed that 9 and 10 peaks are specific to Xoo and Xoc, respectively, which can be used as biomarkers to identify and differentiate the two closely related pathovars. Furthermore, FTIR analysis showed that there is a significant difference in both the band frequencies and absorption intensity of various functional groups between the two pathovars. In particular, the 6 peaks at 3433, 2867, 1273, 1065, 983 and 951 cm-1 were specific to the Xoo strains, while one peak at 1572 cm-1 was specific to the Xoc strains. Overall, this study gives the first attempt to identify and differentiate the two pathovars of X. oryzae based on mass and FTIR spectra, which will be helpful for the early detection and prevention of the two rice diseases caused by both X. oryzae pathovars.

  5. Preliminary use of nematic liquid crystal adaptive optics with a 2.16-meter reflecting telescope.

    PubMed

    Cao, Zhaoliang; Mu, Quanquan; Hu, Lifa; Li, Dayu; Peng, Zenghui; Liu, Yonggang; Xuan, Li

    2009-02-16

    A nematic liquid crystal adaptive optics system (NLC AOS) was assembled for a 2.16-m telescope to correct for atmospheric turbulence. LC AOS was designed and optimized with Zemax optical software. Second, an adaptive correction experiment was performed in the laboratory to test the performance of the NLC AOS. After the correction, the peak to valley (PV) and root mean square (RMS) of the wavefront were down to 0.2 lambda (lambda=633 nm) and 0.05 lambda, respectively. Finally, the star of Pollux (beta Gem) was tracked using the 2.16-m Reflecting Telescope, and real time correction of the atmospheric turbulence was performed with the NLC AOS. After the adaptive correction, the average PV and RMS of the wavefront were reduced from 11 lambda and 2.5 lambda to 2.3 lambda and 0.6 lambda, respectively. Although the intensity distribution of the beta Gem was converged and its peak was sharp, a halo still existed around the peak. These results indicated that the NLC AOS only partially corrected the vertical atmospheric turbulence. The limitations of our NLC AOS are discussed and some proposals are made.

  6. EPA'S PHOTOVOLTAIC DEMAND-SIDE MANAGEMENT COST-SHARED DEMONSTRATIONS

    EPA Science Inventory

    The paper discusses an investigation of how photovoltaics (PV) may be used as both a pollution-mitigating energy replacement for fossil fuels and a demand-side management (DSM) option to reduce peak electrical demands of commercial and residential buildings. leven electric utilit...

  7. U.S. EPA'S PHOTOVOLTAIC DEMAND-SIDE MANAGEMENT PROJECT

    EPA Science Inventory

    The paper discusses an investigation of how photovoltaic (PV) may be used as both a pollution-mitigating energy replacement for fossil fuels and a demand-side management (DSM) option to reduce peak electrical demands of commercial and residential buildings. leven electric utiliti...

  8. Hypervolemia in men from drinking hyperhydration fluids at rest and during exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Looftwilson, R.; Wisherd, P. P.; Fung, P. P.; Ertl, A. C.; Jackson, C. G. R.; Barnes, P. R.; Wong, L. G.

    1994-01-01

    To test the hypothesis that drink composition is more important than drink osmolality (Osm) for maintaining and increasing plasma volume (PV) at rest and during exercise, six men (22-39 yr, 76.84 +/- 16.19 kg, 2.99 +/- 0.45 L/min VO2 peak) each underwent six treatments while sitting for 90 min (VO2 = 0.39 L/min) and then performed upright ergometer exercise for 70 min (VO2 = 2.08 +/- 0.33 1/min, 70% +/- 7% VO2 peak). Drink formulations (10 ml/kg body weight, X = 768 ml) for the sitting period were: P1 (55 mEq Na(+), 365 mOsm/kg H2O), P2 (97.1 mEq Na(+), 791 mOsm/kg), P2G (113 mEqNa(+), 80 ml glycerol, 1,382 mOsm/kg, HyperAde (HA) (164 mEq Na(+), 253 mOsm/kg), and 01 and 02 (no drinking). The exercise drink (10 ml/kg, 768 ml) was P1 for all treatments except 02. Plasma volume at rest increased (p less than 0.05) by 4.7% with P1 and by 7.9% with HA. Percent change in PV during exercise was +1% to +3%0(NS) with HA; -6% to 0% (NS) with P1, P2, P2G, and 01; and -8% to -5% (p less than 0.05) with 02. HyperAde, with the lowest osmolality (253 mOsm/kg), maintained PV at rest and during exercise, whereas the other drinks with lower Na(+) and higher osmolality (365 to 1,382 mOsm/kg) did not. But Performance 1 also increased PV at rest. Thus, drink composition may be more important than drink osmolality for increasing plasma volume at rest and for maintaining it during exercise.

  9. Distinguishing Playing Status Through a Functionally Relevant Performance Measure in Female Division I Collegiate Soccer Athletes.

    PubMed

    Magrini, Mitchel A; Colquhoun, Ryan J; Sellers, John H; Conchola, Eric C; Hester, Garrett M; Thiele, Ryan M; Pope, Zach K; Smith, Doug B

    2017-06-08

    Although soccer is predominately an endurance sport, high velocity movements may be an important indicator of athletic success. The purpose of this investigation was to establish whether squat jumps (SJ) can differentiate starters from non-starters with a female collegiate division I soccer team. Eighteen female division I soccer athletes were separated into two groups: 9 starters (age: 19.5 ± 1.0; mass = 64.8 ± 11.5 kg; height = 167.5 ± 7.7 cm; games started = 18.2 ± 4.7; minutes played = 1633.8 ± 478.2 min) and 9 non-starters (age: 19.4 ± 1.4 years; mass = 63.3 ± 4.2 kg; height = 164.7 ± 6.8 cm; games started 0.7 ± 1.3; minutes played 158.2 ± 269.3). Each athlete performed 3 maximal SJs at a starting knee angle of 110° without arm swing. Each participant's SJ height, mean power (MP), peak power (PP), mean velocity (MV), and peak velocity (PV) were measured during each attempt by a linear position transducer (LPT). No statistically significant differences (p ≥ 0.05) in MP and PP between the starters and non-starters were observed. However, starters performed significantly better than non-starters in SJ height (p = 0.002), MV (p = 0.025), and PV (p = 0.015). Additionally, SJ height was strongly correlated with MV (r = 0.628) and PV (r = 0.647). These findings suggest that SJ height, MV and PV, may be important variables for discriminating differences between starters and non-starters in division I female soccer athletes and a strong indicator of explosive performance.

  10. Monitoring a photovoltaic system during the partial solar eclipse of August 2017

    NASA Astrophysics Data System (ADS)

    Kurinec, Santosh K.; Kucer, Michal; Schlein, Bill

    2018-05-01

    The power output of a 4.85 kW residential photovoltaic (PV) system located in Rochester, NY is monitored during the partial solar eclipse of August 21, 2017. The data is compared with the data on a day before and on the same day, a year ago. The area of exposed solar disk is measured using astrophotography every 16 s of the eclipse. Global solar irradiance is estimated using the eclipse shading, time of the day, location coordinates, atmospheric conditions and panel orientation. A sharp decline, as expected in the energy produced is observed at the time of the peak of the eclipse. The observed data of the PV energy produced is related with the model calculations taking into account solar eclipse coverage and cloudiness conditions. The paper provides a cohesive approach of irradiance calculations and obtaining anticipated PV performance.

  11. Design description of the Schuchuli Village photovoltaic power system

    NASA Technical Reports Server (NTRS)

    Ratajczak, A. F.; Vasicek, R. W.; Delombard, R.

    1981-01-01

    A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

  12. Thin-film filament-based solar cells and modules

    NASA Astrophysics Data System (ADS)

    Tuttle, J. R.; Cole, E. D.; Berens, T. A.; Alleman, J.; Keane, J.

    1997-04-01

    This concept paper describes a patented, novel photovoltaic (PV) technology that is capable of achieving near-term commercialization and profitability based upon design features that maximize product performance while minimizing initial and future manufacturing costs. DayStar Technologies plans to exploit these features and introduce a product to the market based upon these differential positions. The technology combines the demonstrated performance and reliability of existing thin-film PV product with a cell and module geometry that cuts material usage by a factor of 5, and enhances performance and manufacturability relative to standard flat-plate designs. The target product introduction price is 1.50/Watt-peak (Wp). This is approximately one-half the cost of the presently available PV product. Additional features include: increased efficiency through low-level concentration, no scribe or grid loss, simple series interconnect, high voltage, light weight, high-throughput manufacturing, large area immediate demonstration, flexibility, modularity.

  13. A comparative study of artificial intelligent-based maximum power point tracking for photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Hussain Mutlag, Ammar; Mohamed, Azah; Shareef, Hussain

    2016-03-01

    Maximum power point tracking (MPPT) is normally required to improve the performance of photovoltaic (PV) systems. This paper presents artificial intelligent-based maximum power point tracking (AI-MPPT) by considering three artificial intelligent techniques, namely, artificial neural network (ANN), adaptive neuro fuzzy inference system with seven triangular fuzzy sets (7-tri), and adaptive neuro fuzzy inference system with seven gbell fuzzy sets. The AI-MPPT is designed for the 25 SolarTIFSTF-120P6 PV panels, with the capacity of 3 kW peak. A complete PV system is modelled using 300,000 data samples and simulated in the MATLAB/SIMULINK. The AI-MPPT has been tested under real environmental conditions for two days from 8 am to 18 pm. The results showed that the ANN based MPPT gives the most accurate performance and then followed by the 7-tri-based MPPT.

  14. Mean Velocity vs. Mean Propulsive Velocity vs. Peak Velocity: Which Variable Determines Bench Press Relative Load With Higher Reliability?

    PubMed

    García-Ramos, Amador; Pestaña-Melero, Francisco L; Pérez-Castilla, Alejandro; Rojas, Francisco J; Gregory Haff, G

    2018-05-01

    García-Ramos, A, Pestaña-Melero, FL, Pérez-Castilla, A, Rojas, FJ, and Haff, GG. Mean velocity vs. mean propulsive velocity vs. peak velocity: which variable determines bench press relative load with higher reliability? J Strength Cond Res 32(5): 1273-1279, 2018-This study aimed to compare between 3 velocity variables (mean velocity [MV], mean propulsive velocity [MPV], and peak velocity [PV]): (a) the linearity of the load-velocity relationship, (b) the accuracy of general regression equations to predict relative load (%1RM), and (c) the between-session reliability of the velocity attained at each percentage of the 1-repetition maximum (%1RM). The full load-velocity relationship of 30 men was evaluated by means of linear regression models in the concentric-only and eccentric-concentric bench press throw (BPT) variants performed with a Smith machine. The 2 sessions of each BPT variant were performed within the same week separated by 48-72 hours. The main findings were as follows: (a) the MV showed the strongest linearity of the load-velocity relationship (median r = 0.989 for concentric-only BPT and 0.993 for eccentric-concentric BPT), followed by MPV (median r = 0.983 for concentric-only BPT and 0.980 for eccentric-concentric BPT), and finally PV (median r = 0.974 for concentric-only BPT and 0.969 for eccentric-concentric BPT); (b) the accuracy of the general regression equations to predict relative load (%1RM) from movement velocity was higher for MV (SEE = 3.80-4.76%1RM) than for MPV (SEE = 4.91-5.56%1RM) and PV (SEE = 5.36-5.77%1RM); and (c) the PV showed the lowest within-subjects coefficient of variation (3.50%-3.87%), followed by MV (4.05%-4.93%), and finally MPV (5.11%-6.03%). Taken together, these results suggest that the MV could be the most appropriate variable for monitoring the relative load (%1RM) in the BPT exercise performed in a Smith machine.

  15. Novel optimization technique of isolated microgrid with hydrogen energy storage.

    PubMed

    Beshr, Eman Hassan; Abdelghany, Hazem; Eteiba, Mahmoud

    2018-01-01

    This paper presents a novel optimization technique for energy management studies of an isolated microgrid. The system is supplied by various Distributed Energy Resources (DERs), Diesel Generator (DG), a Wind Turbine Generator (WTG), Photovoltaic (PV) arrays and supported by fuel cell/electrolyzer Hydrogen storage system for short term storage. Multi-objective optimization is used through non-dominated sorting genetic algorithm to suit the load requirements under the given constraints. A novel multi-objective flower pollination algorithm is utilized to check the results. The Pros and cons of the two optimization techniques are compared and evaluated. An isolated microgrid is modelled using MATLAB software package, dispatch of active/reactive power, optimal load flow analysis with slack bus selection are carried out to be able to minimize fuel cost and line losses under realistic constraints. The performance of the system is studied and analyzed during both summer and winter conditions and three case studies are presented for each condition. The modified IEEE 15 bus system is used to validate the proposed algorithm.

  16. Novel optimization technique of isolated microgrid with hydrogen energy storage

    PubMed Central

    Abdelghany, Hazem; Eteiba, Mahmoud

    2018-01-01

    This paper presents a novel optimization technique for energy management studies of an isolated microgrid. The system is supplied by various Distributed Energy Resources (DERs), Diesel Generator (DG), a Wind Turbine Generator (WTG), Photovoltaic (PV) arrays and supported by fuel cell/electrolyzer Hydrogen storage system for short term storage. Multi-objective optimization is used through non-dominated sorting genetic algorithm to suit the load requirements under the given constraints. A novel multi-objective flower pollination algorithm is utilized to check the results. The Pros and cons of the two optimization techniques are compared and evaluated. An isolated microgrid is modelled using MATLAB software package, dispatch of active/reactive power, optimal load flow analysis with slack bus selection are carried out to be able to minimize fuel cost and line losses under realistic constraints. The performance of the system is studied and analyzed during both summer and winter conditions and three case studies are presented for each condition. The modified IEEE 15 bus system is used to validate the proposed algorithm. PMID:29466433

  17. Handling of drug-related emergencies: an evaluation of emergency medical dispatch.

    PubMed

    Tonje, Lorem; Elisabeth, Saether; Lars, Wik

    2009-02-01

    Documenting the quality of emergency dispatch centres handling of emergency calls regarding intoxicated unconscious patients. Interview with eight emergency dispatch centre directors and a nationwide survey among 313 dispatchers in Norway were performed. In addition, a customized scoring system was used to evaluate dispatcher log recordings of real cases. The recordings were compared with information from corresponding ambulance records. Ninety-nine percent of the dispatchers stated that they used the Norwegian protocol for medical emergencies and 89% of them found it useful. The interviews, the survey, and the recordings, however, documented frequent deviation from the protocol. This instructs ambulance dispatch for any unconscious patient, but 21% stated that they would not dispatch any resource for an unconscious patient without further survey in alcohol-related cases. This was significantly more often (P<0.05) than for the narcotic, combination and prescription - drug-related cases with 4, 10 and 7%, respectively. The recordings revealed deviation from the protocol with dispatchers only determining the patients' level of consciousness and respiratory status in 64 and 70% of the cases, respectively. For 16% of the cases, the dispatcher did not ask the caller about consciousness at all, even though these patients later were found with reduced consciousness. On the basis of the interviews and the survey, cases were handled according to guidelines. The log recordings, however, disclosed deviation from the protocol. Alcohol intoxication was associated with higher rate of deviation from the protocol compared with other intoxications.

  18. The effect of work shift configurations on emergency medical dispatch center response.

    PubMed

    Montassier, Emmanuel; Labady, Julien; Andre, Antoine; Potel, Gilles; Berthier, Frederic; Jenvrin, Joel; Penverne, Yann

    2015-01-01

    It has been proved that emergency medical dispatch centers (EMDC) save lives by promoting an appropriate allocation of emergency medical service resources. Indeed, optimal dispatcher call duration is pivotal to reduce the time gap between the time a call is placed and the delivery of medical care. However, little is known about the impact of work shift configurations (i.e., work shift duration and work shift rotation throughout the day) and dispatcher call duration. Thus, the objective of our study was to assess the effect of work shift configurations on dispatcher call duration. During a 1-year study period, we analyzed the dispatcher call durations for medical and trauma calls during the 4 different work shift rotations (day, morning, evening, and night) and during the 10-hour work shift of each dispatcher in the EMDC of Nantes. We extracted dispatcher call durations from our advanced telephone system, configured with CC Pulse + (Genesys, Alcatel Lucent), and collected them in a custom designed database (Excel, Microsoft). Afterward, we analyzed these data using linear mixed effects models. During the study period, our EMDC received 408,077 calls. Globally, the mean dispatcher call duration was 107 ± 45 seconds. Based on multivariate linear mixed effects models, the dispatcher call duration was affected by night work shift and work shift duration greater than 8 hours, increasing it by about 10 ± 1 seconds and 4 ± 1 seconds, respectively (both p < 0.001). Our study showed that there was a statistically significant difference in dispatcher call duration over work shift rotation and duration, with longer durations seen over night shifts and shifts over 8 hours. While these differences are small and may not have clinical significance, they may have implications for EMDC efficiency.

  19. Effect and accuracy of emergency dispatch telephone guidance to bystanders in trauma: post-hoc analysis of a prospective observational study.

    PubMed

    Bakke, Håkon Kvåle; Steinvik, Tine; Ruud, Håkon; Wisborg, Torben

    2017-03-07

    Emergency medical communication centres (EMCCs) dispatch and allocate ambulance resources, and provide first-aid guidance to on-scene bystanders. We aimed to 1) evaluate whether dispatcher guidance improved bystander first aid in trauma, and 2) to evaluate whether dispatchers and on-scene emergency medical services (EMS) crews identified the same first aid measures as indicated. For 18 months, the crew on the first EMS crew responding to trauma calls used a standard form to assess bystander first aid. Audio recordings of the corresponding telephone calls from bystanders to the EMCC were reviewed. A total of 311 trauma calls were included. The on-scene EMS crew identified needs for the following first-aid measures: free airway in 26 patients, CPR in 6 patients, and hypothermia prevention in 179 patients. EMCC dispatchers advised these measures, respectively, in 16 (62%), 5 (83%), and 54 (30%) of these cases. Dispatcher guidance was not correlated with correctly performed bystander first aid. For potentially life saving first aid measures, all (20/20) callers who received dispatcher guidance attempted first aid, while only some few (4/22) of the callers who did not receive dispatcher guidance did not attempt first aid. Overall, the EMCC dispatchers had low sensitivity and specificity for correctly identifying trauma patients requiring first-aid measures. Dispatcher guidance did not significantly influence whether on-scene bystander first aid was performed correctly or attempted in this study setting, with a remarkably high willingness to perform first-aid. However, the findings for potentially lifesaving measures suggests that there may be differences that this study was unable to detect. This study found a high rate of first-aid willingness and performance, even without dispatcher prompting, and a low precision in dispatcher advice. This underlines the need for further knowledge about how to increase EMCC dispatchers' possibility to identify trauma patients in need of first aid. The correlation between EMCC-guidance and bystander first aid should be investigated in study settings with lower spontaneous first-aid rates.

  20. Is $50/MWh solar for real? Falling project prices and rising capacity factors drive utility-scale PV toward economic competitiveness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolinger, Mark; Weaver, Samantha; Zuboy, Jarett

    Recently announced low-priced power purchase agreements (PPAs) for US utility-scale photovoltaic (PV) projects suggest $50/MWh solar might be viable under certain conditions. To explore this possibility, this paper draws on an increasing wealth of empirical data to analyze trends in three of the most important PPA price drivers: upfront installed project prices, operations, and maintenance (O&M) costs, and capacity factors. Average installed prices among a sample of utility-scale PV projects declined by more than one third (from 5.8/W AC to 3.7/WAC) from the 2007–2009 period through 2013, even as costlier systems with crystalline-silicon modules, sun tracking, and higher inverter loadingmore » ratios (ILRs) have constituted an increasing proportion of total utility-scale PV capacity (all values shown here are in 2013 dollars). Actual and projected O&M costs from a very small sample of projects appear to range from $20–$40/kW AC-year. Furthermore, the average net capacity factor is 30% for projects installed in 2012, up from 24% for projects installed in 2010, owing to better solar resources, higher ILRs, and greater use of tracking among the more recent projects. Based on these trends, a pro-forma financial model suggests that $50/MWh utility-scale PV is achievable using a combination of aggressive-but-achievable technical and financial input parameters (including receipt of the 30% federal investment tax credit). Although the US utility-scale PV market is still young, the rapid progress in the key metrics documented in this paper has made PV a viable competitor against other utility-scale renewable generators, and even conventional peaking generators, in certain regions of the country.« less

  1. Is $50/MWh solar for real? Falling project prices and rising capacity factors drive utility-scale PV toward economic competitiveness

    DOE PAGES

    Bolinger, Mark; Weaver, Samantha; Zuboy, Jarett

    2015-05-22

    Recently announced low-priced power purchase agreements (PPAs) for US utility-scale photovoltaic (PV) projects suggest $50/MWh solar might be viable under certain conditions. To explore this possibility, this paper draws on an increasing wealth of empirical data to analyze trends in three of the most important PPA price drivers: upfront installed project prices, operations, and maintenance (O&M) costs, and capacity factors. Average installed prices among a sample of utility-scale PV projects declined by more than one third (from 5.8/W AC to 3.7/WAC) from the 2007–2009 period through 2013, even as costlier systems with crystalline-silicon modules, sun tracking, and higher inverter loadingmore » ratios (ILRs) have constituted an increasing proportion of total utility-scale PV capacity (all values shown here are in 2013 dollars). Actual and projected O&M costs from a very small sample of projects appear to range from $20–$40/kW AC-year. Furthermore, the average net capacity factor is 30% for projects installed in 2012, up from 24% for projects installed in 2010, owing to better solar resources, higher ILRs, and greater use of tracking among the more recent projects. Based on these trends, a pro-forma financial model suggests that $50/MWh utility-scale PV is achievable using a combination of aggressive-but-achievable technical and financial input parameters (including receipt of the 30% federal investment tax credit). Although the US utility-scale PV market is still young, the rapid progress in the key metrics documented in this paper has made PV a viable competitor against other utility-scale renewable generators, and even conventional peaking generators, in certain regions of the country.« less

  2. The use of peripheral vision to guide perturbation-evoked reach-to-grasp balance-recovery reactions

    PubMed Central

    King, Emily C.; McKay, Sandra M.; Cheng, Kenneth C.

    2016-01-01

    For a reach-to-grasp reaction to prevent a fall, it must be executed very rapidly, but with sufficient accuracy to achieve a functional grip. Recent findings suggest that the CNS may avoid potential time delays associated with saccade-guided arm movements by instead relying on peripheral vision (PV). However, studies of volitional arm movements have shown that reaching is slower and/or less accurate when guided by PV, rather than central vision (CV). The present study investigated how the CNS resolves speed-accuracy trade-offs when forced to use PV to guide perturbation-evoked reach-to-grasp balance-recovery reactions. These reactions were evoked, in 12 healthy young adults, via sudden unpredictable anteroposterior platform translation (barriers deterred stepping reactions). In PV trials, subjects were required to look straight-ahead at a visual target while a small cylindrical handhold (length 25%> hand-width) moved intermittently and unpredictably along a transverse axis before stopping at a visual angle of 20°, 30°, or 40°. The perturbation was then delivered after a random delay. In CV trials, subjects fixated on the handhold throughout the trial. A concurrent visuo-cognitive task was performed in 50% of PV trials but had little impact on reach-to-grasp timing or accuracy. Forced reliance on PV did not significantly affect response initiation times, but did lead to longer movement times, longer time-after-peak-velocity and less direct trajectories (compared to CV trials) at the larger visual angles. Despite these effects, forced reliance on PV did not compromise ability to achieve a functional grasp and recover equilibrium, for the moderately large perturbations and healthy young adults tested in this initial study. PMID:20957351

  3. Automatic low-order aberrations compensator for a conduction-cooled end-pumped solid-state zigzag slab laser

    NASA Astrophysics Data System (ADS)

    Yu, Xin; Dong, Lizhi; Lai, Boheng; Yang, Ping; Wang, Shuai; Wang, Xun; Liu, Yong; Tang, Guomao; Xu, Bing

    2017-11-01

    In order to solve the problem of large low-order aberrations with solid-state zigzag slab lasers, an automatic compensator has been developed in this paper. In this compensator, three lenses are mounted on a motorized rail, whose positions can be obtained using ray tracing method based on the beam parameters detected by a wave-front sensor. The initial peak to valley (PV) values of the wave-front range up to several tens of microns. Both simulated and experimental results show that the PV values of the wave-front can be reduced to around 1 . 6 μm with the proposed automatic compensator.

  4. Effects of Solar Photovoltaic Panels on Roof Heat Transfer

    NASA Technical Reports Server (NTRS)

    Dominguez, A.; Klessl, J.; Samady, M.; Luvall, J. C.

    2010-01-01

    Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

  5. Dispatcher assistance and automated external defibrillator performance among elders.

    PubMed

    Ecker, R; Rea, T D; Meischke, H; Schaeffer, S M; Kudenchuk, P; Eisenberg, M S

    2001-10-01

    Automated external defibrillators (AEDs) provide an opportunity to improve survival in out-of-hospital, ventricular fibrillation (VF) cardiac arrest by enabling laypersons not trained in rhythm recognition to deliver lifesaving therapy. The potential role of emergency dispatchers in the layperson use of AEDs is uncertain. This study was performed to examine whether dispatcher telephone assistance affected AED skill performance during a simulated VF cardiac arrest among a cohort of older adults. The hypothesis was that dispatcher assistance would increase the proportion who were able to correctly deliver a shock, but might require additional time. One hundred fifty community-dwelling persons aged 58-84 years were recruited from eight senior centers in King County, Washington. All participants had received AED training approximately six months previously. For this study, the participants were randomized to AED operation with or without dispatcher assistance during a simulated VF cardiac arrest. The proportions who successfully delivered a shock and the time intervals from collapse to shock were compared between the two groups. The participants who received dispatcher assistance were more likely to correctly deliver a shock with the AED during the simulated VF cardiac arrest (91% vs 68%, p = 0.001). Among those who were able to deliver a shock, the participants who received dispatcher assistance required a longer time interval from collapse to shock [median (25th, 75th percentile) = 193 seconds (165, 225) for dispatcher assistance, and 148 seconds (138, 166) for no dispatcher assistance, p = 0.001]. Among older laypersons previously trained in AED operation, dispatcher assistance may increase the proportion who can successfully deliver a shock during a VF cardiac arrest.

  6. Multicriteria meta-heuristics for AGV dispatching control based on computational intelligence.

    PubMed

    Naso, David; Turchiano, Biagio

    2005-04-01

    In many manufacturing environments, automated guided vehicles are used to move the processed materials between various pickup and delivery points. The assignment of vehicles to unit loads is a complex problem that is often solved in real-time with simple dispatching rules. This paper proposes an automated guided vehicles dispatching approach based on computational intelligence. We adopt a fuzzy multicriteria decision strategy to simultaneously take into account multiple aspects in every dispatching decision. Since the typical short-term view of dispatching rules is one of the main limitations of such real-time assignment heuristics, we also incorporate in the multicriteria algorithm a specific heuristic rule that takes into account the empty-vehicle travel on a longer time-horizon. Moreover, we also adopt a genetic algorithm to tune the weights associated to each decision criteria in the global decision algorithm. The proposed approach is validated by means of a comparison with other dispatching rules, and with other recently proposed multicriteria dispatching strategies also based on computational Intelligence. The analysis of the results obtained by the proposed dispatching approach in both nominal and perturbed operating conditions (congestions, faults) confirms its effectiveness.

  7. Diamond encapsulated photovoltaics for transdermal power delivery.

    PubMed

    Ahnood, A; Fox, K E; Apollo, N V; Lohrmann, A; Garrett, D J; Nayagam, D A X; Karle, T; Stacey, A; Abberton, K M; Morrison, W A; Blakers, A; Prawer, S

    2016-03-15

    A safe, compact and robust means of wireless energy transfer across the skin barrier is a key requirement for implantable electronic devices. One possible approach is photovoltaic (PV) energy delivery using optical illumination at near infrared (NIR) wavelengths, to which the skin is highly transparent. In the work presented here, a subcutaneously implantable silicon PV cell, operated in conjunction with an external NIR laser diode, is developed as a power delivery system. The biocompatibility and long-term biostability of the implantable PV is ensured through the use of an hermetic container, comprising a transparent diamond capsule and platinum wire feedthroughs. A wavelength of 980 nm is identified as the optimum operating point based on the PV cell's external quantum efficiency, the skin's transmission spectrum, and the wavelength dependent safe exposure limit of the skin. In bench-top experiments using an external illumination intensity of 0.7 W/cm(2), a peak output power of 2.7 mW is delivered to the implant with an active PV cell dimension of 1.5 × 1.5 × 0.06 mm(3). This corresponds to a volumetric power output density of ~20 mW/mm(3), significantly higher than power densities achievable using inductively coupled coil-based approaches used in other medical implant systems. This approach paves the way for further ministration of bionic implants. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Exploring Demand Charge Savings from Commercial Solar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darghouth, Naim; Barbose, Galen; Mills, Andrew

    Commercial retail electricity rates commonly include a demand charge component, based on some measure of the customer’s peak demand. Customer-sited solar PV can potentially reduce demand charges, but the magnitude of these savings can be difficult to predict, given variations in demand charge designs, customer loads, and PV generation profiles. Moreover, depending on the circumstances, demand charges from solar may or may not align well with associated utility cost savings. Lawrence Berkeley National Laboratory (Berkeley Lab) and the National Renewable Energy Laboratory (NREL) are collaborating in a series of studies to understand how solar PV can reduce demand charge levelsmore » for a variety of customer types and demand charges designs. Previous work focused on residential customs with solar. This study, instead, focuses on commercial customers and seeks to understand the extent and conditions under which rooftop can solar reduce commercial demand charges. To answer these questions, we simulate demand charge savings for a broad range of commercial customer types, demand charge designs, locations, and PV system characteristics. This particular analysis does not include storage, but a subsequent analysis in this series will evaluate demand charge savings for commercial customers with solar and storage.« less

  9. Single Active Switch PV Inverter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramanan, V. R.; Pan, Zhiguo

    This report presents a new PV inverter topology that uses only one active switch instead of 7 active switches in a conventional PV inverter. It has a buck boost converter and operates at discontinuous current control mode, which can reduce the output stage from an active switch bridge to a thyristor bridge. This concept, if successfully demonstrated, may have great cost and size/weight benefits over conventional solutions. Since the proposed topology is completely different from the traditional boost converter plus voltage source inverter approach, there is no existing control/modulation scheme available. A new modulation scheme for both the main switchmore » and the thyristors has been developed. An active clamping circuit has also been proposed to reduce switching losses and voltage spike during the switching transient. A simulation model has been set up to validate the control algorithm and clamping circuit. Simulated results show that a proposed 10 kW PV inverter can reach 5% total harmonic distortion (THD), 98.8% peak efficiency with only one main active switch, and an inductor weighing less than 3 kg. Based on that, a 10 kW prototype converter has been designed and built.« less

  10. Intermediate Photovoltaic System Application Experiment. Oklahoma Center for Science and Arts. Phase II. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report presents the key results of the Phase II efforts for the Intermediate PV System Applications Experiment at the Oklahoma Center for Science and Arts (OCSA). This phase of the project involved fabrication, installation and integration of a nominal 140 kW flat panel PV system made up of large, square polycrystalline-silicon solar cell modules, each nominally 61 cm x 122 cm in size. The output of the PV modules, supplied by Solarex Corporation, was augmented, 1.35 to 1 at peak, by a row of glass reflectors, appropriately tilted northward. The PV system interfaces with the Oklahoma Gas and Electricmore » Utility at the OCSA main switchgear. Any excess power generated by the system is fed into the utility under a one to one buyback arrangement. Except for a shortfall in the system output, presently suspected to be due to the poor performance of the modules, no serious problems were encountered. Certain value engineering changes implemented during construction and early operational failure events associated with the power conditioning system are also described. The system is currently undergoing extended testing and evaluation.« less

  11. Cardiovascular response to prescribed detraining among recreational athletes.

    PubMed

    Pedlar, Charles R; Brown, Marcel G; Shave, Robert E; Otto, James M; Drane, Aimee; Michaud-Finch, Jennifer; Contursi, Miranda; Wasfy, Meagan M; Hutter, Adolph; Picard, Michael H; Lewis, Gregory D; Baggish, Aaron L

    2018-04-01

    Exercise-induced cardiac remodeling (EICR) and the attendant myocardial adaptations characteristic of the athlete's heart may regress during periods of exercise reduction or abstinence. The time course and mechanisms underlying this reverse remodeling, specifically the impact of concomitant plasma volume (PV) contraction on cardiac chamber size, remain incompletely understood. We therefore studied recreational runners ( n = 21, age 34 ± 7 yr; 48% male) who completed an 18-wk training program (~7 h/wk) culminating in the 2016 Boston Marathon after which total exercise exposure was confined to <2 h/wk (no single session >1 h) for 8 wk. Cardiac structure and function, exercise capacity, and PV were assessed at peak fitness (10-14 days before) and at 4 wk and 8 wk postmarathon. Mixed linear modeling adjusting for age, sex, V̇o 2peak , and marathon finish time was used to compare data across time points. Physiological detraining was evidenced by serial reductions in treadmill performance. Two distinct phases of myocardial remodeling and hematological adaptation were observed. After 4 wk of detraining, there were significant reductions in PV (Δ -6.0%, P < 0.01), left ventricular (LV) wall thickness (Δ -8.1%, <0.05), LV mass (Δ -10.3%, P < 0.001), and right atrial area (Δ -8.2%, P < 0.001). After 8 wk of detraining, there was a significant reduction in right ventricle chamber size (end-diastolic area Δ = -8.0%, P < 0.05) without further concomitant reductions in PV or LV wall thickness. Abrupt reductions in exercise training stimulus result in a structure-specific time course of reverse cardiac remodeling that occurs largely independently of PV contraction. NEW & NOTEWORTHY Significant reverse cardiac remodeling, previously documented among competitive athletes, extends to recreational runners and occurs with a distinct time course. Initial reductions in plasma volume and left ventricular (LV) mass, driven by reductions in wall thickness, are followed by contraction of the right ventricle. Consistent with data from competitive athletes, LV chamber volumes appear less responsive to detraining and may be a more permanent adaptation to sport.

  12. Effects of Dispatcher-assisted Cardiopulmonary Resuscitation on Survival Outcomes in Infants, Children, and Adolescents with Out-of-hospital Cardiac Arrests.

    PubMed

    Ro, Young Sun; Shin, Sang Do; Song, Kyoung Jun; Hong, Ki Jeong; Ahn, Ki Ok; Kim, Do Kyun; Kwak, Young Ho

    2016-11-01

    We studied the effect of a dispatcher-assisted cardiopulmonary resuscitation (CPR) program on paediatric out-of-hospital cardiac arrest (OHCA) outcomes by age groups. All emergency medical services (EMS)-treated paediatric OHCAs in Korea were enrolled between 2012 and 2014, excluding cases witnessed by EMS providers and those with unknown outcomes. The cases were divided into three groups: bystander CPR with dispatcher assistance, bystander CPR without dispatcher assistance, and no-bystander CPR. The endpoint was survival until discharge from hospital. Multivariable logistic regression analysis was performed. The final model with an interaction term was evaluated to compare the effects across age groups. A total of 1529 patients (32.8% bystander CPR with dispatcher assistance, 17.3% without dispatcher assistance, and 54.6% no-bystander CPR) were included. Both bystander CPR groups were more likely to have higher rate of survival to discharge (8.8% and 12.1%) compared to no-bystander CPR (3.9%). The adjusted OR (95% CI) for survival to discharge were 1.77 (1.04-3.00) in bystander CPR with dispatcher assistance and 2.86 (1.61-5.08) in without dispatcher assistance compared with no-bystander CPR. By age groups, the adjusted OR (95% CI) in bystander CPR with and without dispatcher assistance were 2.18 (1.07-4.42) and 2.27 (1.01-5.14) for the group aged 9-18 years; 2.32 (0.64-8.44) and 6.21 (1.83-21.01) for the group aged 1-8 years; 1.06 (0.41-2.77) and 2.00 (0.64-6.18) for the group aged 0-12 months, respectively. Bystander CPR, regardless of dispatcher assistance, was associated with improved survival outcomes after OHCA in the paediatric population. However, the associations between dispatcher-assisted bystander CPR and survival outcomes varied by age. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Comparison of Medical Priority Dispatch (MPD) and Criteria Based Dispatch (CBD) relating to cardiac arrest calls.

    PubMed

    Hardeland, Camilla; Olasveengen, Theresa M; Lawrence, Rob; Garrison, Danny; Lorem, Tonje; Farstad, Gunnar; Wik, Lars

    2014-05-01

    Prompt emergency medical service (EMS) system activation with rapid delivery of pre-hospital treatment is essential for patients suffering out-of-hospital cardiac arrest (OHCA). The two most commonly used dispatch tools are Medical Priority Dispatch (MPD) and Criteria Based Dispatch (CBD). We compared cardiac arrest call processing using these two dispatch tools in two different dispatch centres. Observational study of adult EMS confirmed (non-EMS witnessed) OHCA calls during one year in Richmond, USA (MPD) and Oslo, Norway (CBD). Patients receiving CPR prior to call, interrupted calls or calls where the caller did not have access to the patients were excluded from analysis. Dispatch logs, ambulance records and digitalized dispatcher and caller voice recordings were compared. The MPDS-site processed 182 cardiac arrest calls and the CBD-site 232, of which 100 and 140 calls met the inclusion criteria, respectively. The recognition of cardiac arrest was not different in the MPD and CBD systems; 82% vs. 77% (p=0.42), and pre-EMS arrival CPR instructions were offered to 81% vs. 74% (p=0.22) of callers, respectively. Time to ambulance dispatch was median (95% confidence interval) 15 (13, 17) vs. 33 (29, 36) seconds (p<0.001) and time to chest compression delivery; 4.3 (3.7, 4.9) vs. 3.7 (3.0, 4.1)min for the MPD and CBD systems, respectively (p=0.05). Pre-arrival CPR instructions were offered faster and more frequently in the CBD system, but in both systems chest compressions were delayed 3-4min. Earlier recognition of cardiac arrest and improved CPR instructions may facilitate earlier lay rescuer CPR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Emergency medical dispatch : national standard curriculum ready

    DOT National Transportation Integrated Search

    1996-05-01

    This Traffic Tech describes the recently updated "Emergency Medical Dispatch: National Standard Curriculum," which was developed in 1972. Emergency service providers use these uniform standards to develop or select an emergency medical dispatch progr...

  15. Ambulance dispatches to schools during a 5-year period in Fukui Prefecture.

    PubMed

    Takinami, Yoshikazu; Maeda, Shinji

    2017-01-01

    To determine the characteristics and trends of medical emergencies during school activities by analyzing information provided by fire departments. During a 5-year period from January 2009 to December 2013, all nine fire departments in Fukui Prefecture handled 850 emergencies at schools. We investigated the 850 cases with the age range of 0-63 years. It was found that 21.5% of ambulance dispatches to schools were on weekends and there were more dispatches for non-faculty members of all age groups on weekends than on weekdays. The percentage of weekend dispatches was particularly high for students aged ≥19 years. Emergency calls for junior high school students and younger students accounted for the majority of weekday calls. There were a total of 524 ambulance dispatches for the three categories "sprains, contusions, dislocations, and fractures" ( n = 245), "seizures, epilepsy, and syncope" ( n = 171), and "cuts, bruises, lacerations, trauma, amputations, and burns" ( n = 108), with dispatches for these three categories accounting for 61.6% of all dispatches. Almost all dispatches for "heat stroke and dehydration" were during school hours and were concentrated between the months of July and September. Heat stroke was most common among high school students and most often occurred during the summer/fall season and on weekends. Heat stroke was the fourth most frequent condition that required an ambulance dispatch after the above three conditions. Heat stroke is predictable, indicating that it is necessary to prevent heat stroke during high school club activities.

  16. Real -time dispatching modelling for trucks with different capacities in open pit mines / Modelowanie w czasie rzeczywistym przewozów ciężarówek o różnej ładowności w kopalni odkrywkowej

    NASA Astrophysics Data System (ADS)

    Ahangaran, Daryoush Kaveh; Yasrebi, Amir Bijan; Wetherelt, Andy; Foster, Patrick

    2012-10-01

    Application of fully automated systems for truck dispatching plays a major role in decreasing the transportation costs which often represent the majority of costs spent on open pit mining. Consequently, the application of a truck dispatching system has become fundamentally important in most of the world's open pit mines. Recent experiences indicate that by decreasing a truck's travelling time and the associated waiting time of its associated shovel then due to the application of a truck dispatching system the rate of production will be considerably improved. Computer-based truck dispatching systems using algorithms, advanced and accurate software are examples of these innovations. Developing an algorithm of a computer- based program appropriated to a specific mine's conditions is considered as one of the most important activities in connection with computer-based dispatching in open pit mines. In this paper the changing trend of programming and dispatching control algorithms and automation conditions will be discussed. Furthermore, since the transportation fleet of most mines use trucks with different capacities, innovative methods, operational optimisation techniques and the best possible methods for developing the required algorithm for real-time dispatching are selected by conducting research on mathematical-based planning methods. Finally, a real-time dispatching model compatible with the requirement of trucks with different capacities is developed by using two techniques of flow networks and integer programming.

  17. Multi-objective optimal dispatch of distributed energy resources

    NASA Astrophysics Data System (ADS)

    Longe, Ayomide

    This thesis is composed of two papers which investigate the optimal dispatch for distributed energy resources. In the first paper, an economic dispatch problem for a community microgrid is studied. In this microgrid, each agent pursues an economic dispatch for its personal resources. In addition, each agent is capable of trading electricity with other agents through a local energy market. In this paper, a simple market structure is introduced as a framework for energy trades in a small community microgrid such as the Solar Village. It was found that both sellers and buyers benefited by participating in this market. In the second paper, Semidefinite Programming (SDP) for convex relaxation of power flow equations is used for optimal active and reactive dispatch for Distributed Energy Resources (DER). Various objective functions including voltage regulation, reduced transmission line power losses, and minimized reactive power charges for a microgrid are introduced. Combinations of these goals are attained by solving a multiobjective optimization for the proposed ORPD problem. Also, both centralized and distributed versions of this optimal dispatch are investigated. It was found that SDP made the optimal dispatch faster and distributed solution allowed for scalability.

  18. Research on intelligent power consumption strategy based on time-of-use pricing

    NASA Astrophysics Data System (ADS)

    Fu, Wei; Gong, Li; Chen, Heli; He, Yu

    2017-06-01

    In this paper, through the analysis of shortcomings of the current domestic and foreign household power consumption strategy: Passive way of power consumption, ignoring the different priority of electric equipment, neglecting the actual load pressure of the grid, ignoring the interaction with the user, to decrease the peak-valley difference and improve load curve in residential area by demand response (DR technology), an intelligent power consumption scheme based on time-of-use(TOU) pricing for household appliances is proposed. The main contribution of this paper is: (1) Three types of household appliance loads are abstracted from different operating laws of various household appliances, and the control models and DR strategies corresponding to these types are established. (2) The fuzzified processing for the information of TOU price, which is based on the time intervals, is performed to get the price priority, in accordance with such DR events as the maximum restricted load of DR, the time of DR and the duration of interruptible load and so on, the DR control rule and pre-scheduling mechanism are led in. (3) The dispatching sequence of household appliances in the control and scheduling queue are switched and controlled to implement the equilibrium of peak and valley loads. The equilibrium effects and economic benefits of power system by pre-scheduling and DR dispatching are compared and analyzed by simulation example, and the results show that using the proposed household appliance control (HAC) scheme the overall cost of consumers can be reduced and the power system load can be alleviated, so the proposed household appliance control (HAC) scheme is feasible and reasonable.

  19. Recovery of inter-row shading losses using differential power-processing submodule DC–DC converters

    DOE PAGES

    Doubleday, Kate; Choi, Beomseok; Maksimovic, Dragan; ...

    2016-06-17

    Large commercial photovoltaic (PV) systems can experience regular and predictable energy loss due to both inter-row shading and reduced diffuse irradiance in tightly spaced arrays. This article investigates the advantages of replacing bypass diodes with submodule-integrated DC-DC converters (subMICs) to mitigate these losses. Yearly simulations of commercial-scale PV systems were conducted considering a range of row-to-row pitches. In the limit case of array spacing (unity ground coverage), subMICs can confer a 7% increase in annual energy output and peak energy density (kW h/m 2). Simulation results are based on efficiency assumptions experimentally confirmed by prototype submodule differential power-processing converters.

  20. Seed germination of three Ulmus species from Turkey as influenced by temperature and light.

    PubMed

    Cicek, Emrah; Tilki, Fahrettin

    2007-04-01

    The effect of temperature and light on the germination performance of Ulmus minor, Ulmus glabra and Ulmus laevis were studied in this research. Seeds were germinated under constant temperatures of 20 and 25 degrees C and alternating temperatures of 25/15 and 30/20 degrees C. Within each temperature regime, seeds were subjected daily to the following photoperiods: total darkness and 8 hr photoperiod. Temperature and light affected seed germination percentage (GP) and germination rate expressed as peak value (PV) in Ulmus minor and 25 and 30/20 degrees C under light gave the highest GP (>95%) and PV (>23). The temperatures of 25/15 and 30/20 degrees C gave the highest GP (>89%) in Ulmus glabra and light did not significantly affect GP. But the highest PV in Ulmus glabra was found at these temperatures under light. Germination percentage of Ulmus laevis was not affected by temperature and light, but the alternating temperature of 30/20 degrees C produced the highest germination rate under darkness.

  1. Subsurface damage in some single crystalline optical materials.

    PubMed

    Randi, Joseph A; Lambropoulos, John C; Jacobs, Stephen D

    2005-04-20

    We present a nondestructive method for estimating the depth of subsurface damage (SSD) in some single crystalline optical materials (silicon, lithium niobate, calcium fluoride, magnesium fluoride, and sapphire); the method is established by correlating surface microroughness measurements, specifically, the peak-to-valley (p-v) microroughness, to the depth of SSD found by a novel destructive method. Previous methods for directly determining the depth of SSD may be insufficient when applied to single crystals that are very soft or very hard. Our novel destructive technique uses magnetorheological finishing to polish spots onto a ground surface. We find that p-v surface microroughness, appropriately scaled, gives an upper bound to SSD. Our data suggest that SSD in the single crystalline optical materials included in our study (deterministically microground, lapped, and sawed) is always less than 1.4 times the p-v surface microroughness found by white-light interferometry. We also discuss another way of estimating SSD based on the abrasive size used.

  2. Vascular uptake of rehydration fluids in hypohydrated men at rest and exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Geelen, G.; Jackson, C. G. R.; Saumet, J.-L.; Juhos, L. T.; Keil, L. C.; Fegan-Meyer, D.; Dearborn, A.; Hinghofer-Szalkay, H.; Whittam, J. H.

    1992-01-01

    The purpose of this study was to formulate and to evaluate rehydration drinks, which would restore total body water and plasma volume (PV), for astronauts to consume before and during extravehicular activity, a few hours before reentry, and immediately after landing. In the first experiment (rest, sitting), five healthy men (23-41 yr), previously dehydrated for 24 hr., drank six (1a, 2, 4, 5, 6, 7) fluid formulations (one each at weekly intervals) and then sat for 70 min. Pre-test PV were measured with Evans blue dye and changes in PV were calculated with the hematocrit-hemoglobin transformation equation. This rest experiment simulated hypohydrated astronauts preparing for reentry. The second experiment (exercise, supine) followed the same protocol except four healthy men (30-46 yr) worked for 70 min. in the supine position on a cycle ergometer at a mean load of 71+/-1 percent of their peak aerobic work capacity. This exercise experiment simulated conditions for astronauts with reduced total body water engaging in extravehicular activity.

  3. The Photovoltaic Higher Education National Exemplar Facility (PHENEF)

    NASA Astrophysics Data System (ADS)

    Podbielski, V.; Shaff, D.

    1994-04-01

    In August 1980, the US Department of Energy awarded the proposed grant to Georgetown University. The grant covered the following tasks: Task 1, The Department of Energy would participate in the building of an academic facility that would facilitate the integration of flat plate photovoltaic roof modules with an optimally oriented solar architecture. The completion of the facility to be built on the Georgetown University Campus and known as the Georgetown University Intercultural Center was to be a jointly funded endeavor with the Department of Education funding $9.2M through a grant and a loan, Department of Energy funding a maximum of $4M and Georgetown University funding the residual costs. Task 2, Georgetown University would provide the necessary skills, services, materials, equipment and facilities to design, furnish, install and make operational the Georgetown University Intercultural Center Photovoltaic System. The specific objective of this effort would be to build an exemplar flat plate electrical grid connected photovoltaic (PV) system which would demonstrate integration of PV modules into a watertight roofing surface. The system capability, measured at the input to the inverter, would be a 300 kilowatt peak power system as measured at the normal cell operating temperature and an isolation of 100 milliwatts per square centimeter at the collector surface. DOE funding under the grant for the PV system would be limited to a system cost of $20.00 per peak watt up to maximum of six million dollars.

  4. Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coddington, M. H.; Kroposki, B. D.; Basso, T.

    In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizesmore » current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.« less

  5. Decreasing the dispatch time of medical reports sent from hospital to primary care with Lean Six Sigma.

    PubMed

    Basta, Yara L; Zwetsloot, Inez M; Klinkenbijl, Jean H G; Rohof, Thomas; Monster, Mathijs M C; Fockens, Paul; Tytgat, Kristien M A J

    2016-10-01

    Timely communication is important to ensure high-quality health care. To facilitate this, the Gastro Intestinal Oncology Center Amsterdam (GIOCA) stipulated to dispatch medical reports on the day of the patient's visit. However, with the increasing number of patients, administrative processes at GIOCA were under pressure, and this standard was not met for the majority of patients. The aim and objective of this study was to dispatch 90% of medical reports on the day of the patient's visit by improving the logistic process. To assess the main causes for a prolonged dispatch time and to design improvements actions, the roadmap offered by Lean Six Sigma (LSS) was used, consisting of five phases: Define, Measure, Analyze, Improve and Control (DMAIC roadmap). Initially, 12.3% of the reports were dispatched on the day of the patient's visit. Three causes for a prolonged dispatch time were identified: (1) determining which doctors involved with treatment would compose the report; (2) the reports composed by a senior resident had to be reviewed by a medical specialist; and (3) a medical specialist had to authorize the administration to dispatch the reports. To circumvent these causes, a digital form was implemented in the electronic medical record that could be completed during the multidisciplinary team meeting. After implementation, 90.6% of the reports were dispatched on the day of the visit. The dispatch time of reports sent from hospital to primary care can be significantly reduced using Lean Six Sigma, improving the communication between hospital and primary care. © 2016 John Wiley & Sons, Ltd.

  6. Modeling work of the dispatching service of high-rise building as queuing system

    NASA Astrophysics Data System (ADS)

    Dement'eva, Marina; Dement'eva, Anastasiya

    2018-03-01

    The article presents the results of calculating the performance indicators of the dispatcher service of a high-rise building as a queuing system with an unlimited queue. The calculation was carried out for three models: with a single control room and brigade of service, with a single control room and a specialized service, with several dispatch centers and specialized services. The aim of the work was to investigate the influence of the structural scheme of the organization of the dispatcher service of a high-rise building on the amount of operating costs and the time of processing and fulfilling applications. The problems of high-rise construction and their impact on the complication of exploitation are analyzed. The composition of exploitation activities of high-rise buildings is analyzed. The relevance of the study is justified by the need to review the role of dispatch services in the structure of management of the quality of buildings. Dispatching service from the lower level of management of individual engineering systems becomes the main link in the centralized automated management of the exploitation of high-rise buildings. With the transition to market relations, the criterion of profitability at the organization of the dispatching service becomes one of the main parameters of the effectiveness of its work. A mathematical model for assessing the efficiency of the dispatching service on a set of quality of service indicators is proposed. The structure of operating costs is presented. The algorithm of decision-making is given when choosing the optimal structural scheme of the dispatching service of a high-rise building.

  7. Training requirements for railroad dispatchers : objectives, syllabi and test designs

    DOT National Transportation Integrated Search

    1998-11-01

    This report presents the results of a study to develop railroad dispatcher training objectives, syllabi for three types of training programs and test designs for the three programs. Information about current railroad dispatching methods and training ...

  8. Optimizing Staffing levels and Schedules for Railroad Dispatching Centers

    DOT National Transportation Integrated Search

    2004-09-01

    This report presents the results of a study to explore approaches to establishing staffing levels and schedules for railroad dispatchers. The : work was conducted as follow-up to a prior study that found fatigue among dispatchers, particularly those ...

  9. Dispatch-assisted CPR: where are the hold-ups during calls to emergency dispatchers? A preliminary analysis of caller-dispatcher interactions during out-of-hospital cardiac arrest using a novel call transcription technique.

    PubMed

    Clegg, Gareth R; Lyon, Richard M; James, Scott; Branigan, Holly P; Bard, Ellen G; Egan, Gerry J

    2014-01-01

    Survival from out-of-hospital cardiac arrest (OHCA) is dependent on the chain of survival. Early recognition of cardiac arrest and provision of bystander cardiopulmonary resuscitation (CPR) are key determinants of OHCA survival. Emergency medical dispatchers play a key role in cardiac arrest recognition and giving telephone CPR advice. The interaction between caller and dispatcher can influence the time to bystander CPR and quality of resuscitation. We sought to pilot the use of emergency call transcription to audit and evaluate the holdups in performing dispatch-assisted CPR. A retrospective case selection of 50 consecutive suspected OHCA was performed. Audio recordings of calls were downloaded from the emergency medical dispatch centre computer database. All calls were transcribed using proprietary software and voice dialogue was compared with the corresponding stage on the Medical Priority Dispatch System (MPDS). Time to progress through each stage and number of caller-dispatcher interactions were calculated. Of the 50 downloaded calls, 47 were confirmed cases of OHCA. Call transcription was successfully completed for all OHCA calls. Bystander CPR was performed in 39 (83%) of these. In the remaining cases, the caller decided the patient was beyond help (n = 7) or the caller said that they were physically unable to perform CPR (n = 1). MPDS stages varied substantially in time to completion. Stage 9 (determining if the patient is breathing through airway instructions) took the longest time to complete (median = 59 s, IQR 22-82 s). Stage 11 (giving CPR instructions) also took a relatively longer time to complete compared to the other stages (median = 46 s, IQR 37-75 s). Stage 5 (establishing the patient's age) took the shortest time to complete (median = 5.5s, IQR 3-9s). Transcription of OHCA emergency calls and caller-dispatcher interaction compared to MPDS stage is feasible. Confirming whether a patient is breathing and completing CPR instructions required the longest time and most interactions between caller and dispatcher. Use of call transcription has the potential to identify key factors in caller-dispatcher interaction that could improve time to CPR and further research is warranted in this area. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Understanding how train dispatchers manage and control trains : results of a cognitive task analysis

    DOT National Transportation Integrated Search

    2001-05-01

    This report documents the results of a Cognitive Task Analysis that examined how experienced railroad dispatchers manage and : schedule trains in todays environment. The objective was to understand the cognitive demands placed on railroad dispatch...

  11. Understanding how train dispatchers manage and control trains : results of a cognitive task analysis

    DOT National Transportation Integrated Search

    2001-05-01

    This report documents the results ofaCognitive Task Analysis that examined how experienced railroad dispatchers manage and : schedule trains in today's environment. The objective was to understand the cognitive demands placed on railroad dispatchers ...

  12. Understanding how train dispatchers manage and control trains : results of a cognitive task analysis.

    DOT National Transportation Integrated Search

    2001-05-01

    This report documents the results of a Cognitive Task Analysis that examined how experienced railroad dispatchers manage and schedule trains in todays environment. The objective was to understand the cognitive demands placed on railroad dispatcher...

  13. Testing for Seed Quality in Southern Oaks

    Treesearch

    F.T. Bonner

    1984-01-01

    Expressions of germination rate, such as peak value (PV) or mean germination time (MGT), provide good estimates of acorn quality, but test completion requires a minimum of 3 weeks. For more rapid estimates, tetrazolium staining is recommended. Some seed test results were significantly correlated with nursery germination of cherrybark and water oaks, but not with...

  14. Improving maximum power point tracking of partially shaded photovoltaic system by using IPSO-BELBIC

    NASA Astrophysics Data System (ADS)

    Al-Alim El-Garhy, M. Abd; Mubarak, R. I.; El-Bably, M.

    2017-08-01

    Solar photovoltaic (PV) arrays in remote applications are often related to the rapid changes in the partial shading pattern. Rapid changes of the partial shading pattern make the tracking of maximum power point (MPP) of the global peak through the local ones too difficult. An essential need to make a fast and efficient algorithm to detect the peaks values which always vary as the sun irradiance changes. This paper presents two algorithms based on the improved particle swarm optimization technique one of them with PID controller (IPSO-PID), and the other one with Brain Emotional Learning Based Intelligent Controller (IPSO-BELBIC). These techniques improve the maximum power point (MPP) tracking capabilities for photovoltaic (PV) system under partial shading circumstances. The main aim of these improved algorithms is to accelerate the velocity of IPSO to reach to (MPP) and increase its efficiency. These algorithms also improve the tracking time under complex irradiance conditions. Based on these conditions, the tracking time of these presented techniques improves to 2 msec, with an efficiency of 100%.

  15. Visualizing density perturbations in the capsule shell in NIF implosions near peak velocity

    NASA Astrophysics Data System (ADS)

    Pickworth, L. A.; Hammel, B. A.; Smalyuk, V. A.; Macphee, A.; Scott, H. A.; Robey, H. F.; Field, J.; Barrios, M.; Regan, S. P.

    2016-10-01

    Engineering features on the capsule (surface roughness, support structures, etc.) can introduce outer surface perturbations that are ultimately detrimental to the performance of the capsule. Recent experiments have assessed minimal support structures and alternate pulse shapes using a re-entrant cone and back lighter that is perturbing to the implosion below radii of 500 μ m. Emission from the hot core, after shock-stagnation and prior to peak velocity (PV), has been used as a self-backlighter, providing a means to sample one side of the capsule at smaller radii. Adding high-Z gas ( 1 % Ar) to the capsule fill in Symcaps (4He), has produced a continuum backlighter with significant increase in emission at hv 8 keV over nominal fills. High-resolution imaging diagnostics with photon energy selectivity form 2D images of the transmitted self-emission, above and below the K-edge of an internally doped Cu layer. We can infer from these images the growth at PV of outer surface perturbations. Prepared by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-697620.

  16. Plasma volume shifts and exercise thermoregulation with water immersion and six-degree head-down tilt

    NASA Technical Reports Server (NTRS)

    Ertl, Andrew Carl

    1994-01-01

    The hypothesized fluid shifts and resultant responses that occur during spaceflight are simulated by six-degree head down tilt (HDT) and water immersion (WI). The purpose of this study was to compare exercise thermoregulation before and after physiologic mechanisms reduce plasma volume (PV) in response to 24-hr HDT (HDT24). A secondary study utilized WI to reproduce the PV reduction of HDT24. Seven males were studied in two conditions: during 70 minutes of supine cycling ergometry at 58 percent of peak oxygen consumption following 1-hr HDT (HDT1) and HDT24; and up to 6 hr WI at 34.5 C. Plasma volume was reduced by 10.4 percent in HDT24 when compared to HDT1. Pre-exercise rectal temperature, T(sub re), was an average 0.22 C higher after HDT24. Rectal temperature increased during exercise with no interaction between time and treatment. The reduced PV and elevated pre-exercise T(sub re) had offsetting effects on thermoregulatory mechanisms, suggesting no alteration in the response at a given T(sub re). Plasma volume was reduced by 4.3 +/- 2.3 percent and 1.1 +/- 1.8 percent following HDT24 and WI, respectively, compared to upright chair rest. Although the reductions in PV were not significantly different, great intra-individual variability was evident. The ability to reproduce PV changes consistently with HDT and WI is limited by this variability.

  17. Effect of standing on neurohumoral responses and plasma volume in healthy subjects

    NASA Technical Reports Server (NTRS)

    Jacob, G.; Ertl, A. C.; Shannon, J. R.; Furlan, R.; Robertson, R. M.; Robertson, D.

    1998-01-01

    Upright posture leads to rapid pooling of blood in the lower extremities and shifts plasma fluid into surrounding tissues. This results in a decrease in plasma volume (PV) and in hemoconcentration. There has been no integrative evaluation of concomitant neurohumoral and PV shifts with upright posture in normal subjects. We studied 10 healthy subjects after 3 days of stable Na+ and K+ intake. PV was assessed by the Evans blue dye method and by changes in hematocrit. Norepinephrine (NE), NE spillover, epinephrine (Epi), vasopressin, plasma renin activity, aldosterone, osmolarity, and kidney response expressed by urine osmolality and by Na+ and K+ excretion of the subjects in the supine and standing postures were all measured. We found that PV fell by 13% (375 +/- 35 ml plasma) over approximately 14 min, after which time it remained relatively stable. There was a concomitant decrease in systolic blood pressure and an increase in heart rate that peaked at the time of maximal decrease in PV. Plasma Epi and NE increased rapidly to this point. Epi approached baseline by 20 min of standing. NE spillover increased 80% and clearance decreased 30% with 30 min of standing. The increase in plasma renin activity correlated with an increase in aldosterone. Vasopressin increased progressively, but there was no change in plasma osmolarity. The kidney response showed a significant decrease in Na+ and an increase in K+ excretion with upright posture. We conclude that a cascade of neurohumoral events occurs with upright posture, some of which particularly coincide with the decrease in PV. Plasma Epi levels may contribute to the increment in heart rate with maintained upright posture.

  18. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  19. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  20. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  1. 14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...

  2. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  3. 14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...

  4. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  5. 14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...

  6. 14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...

  7. 14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...

  8. Development of structural diagram of automated dispatch control system for power consumption at non-ferrous metallurgy enterprises

    NASA Astrophysics Data System (ADS)

    Klyuev, R. V.; Bosikov, I. I.; Madaeva, M. Z.; A-V Turluev, R.

    2018-03-01

    The structural scheme of the automated control system of power consumption at the industrial enterprise is developed in the article. At the non-ferrous metallurgy enterprise, an energy inspection and a rank analysis of the electrical energy consumption of the main processing equipment were carried out. It is established that the enterprises of non-ferrous metallurgy are a complex process system consisting of a set of thousands of jointly functioning technological facilities. For the most effective estimation of power consumption of enterprises, it is reasonable to use the automated system of dispatching control of power consumption (ASDCPC). The paper presents the results of the development of the ASDCPC structural diagram that allows one to perform on-line control and management of the energy and process parameters of the main production units and the enterprise as a whole. As a result of the introduction of ASDCPC at the non-ferrous metallurgy enterprise, the consumed active power was reduced during the peak hours of the load by 20%, the specific electricity consumption - by 14%, the cost of the energy component in the cost of production of hard alloys - by 3%.

  9. Research on wind power grid-connected operation and dispatching strategies of Liaoning power grid

    NASA Astrophysics Data System (ADS)

    Han, Qiu; Qu, Zhi; Zhou, Zhi; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Li, Jinze; Ling, Zhaowei

    2018-02-01

    As a kind of clean energy, wind power has gained rapid development in recent years. Liaoning Province has abundant wind resources and the total installed capacity of wind power is in the forefront. With the large-scale wind power grid-connected operation, the contradiction between wind power utilization and peak load regulation of power grid has been more prominent. To this point, starting with the power structure and power grid installation situation of Liaoning power grid, the distribution and the space-time output characteristics of wind farm, the prediction accuracy, the curtailment and the off-grid situation of wind power are analyzed. Based on the deep analysis of the seasonal characteristics of power network load, the composition and distribution of main load are presented. Aiming at the problem between the acceptance of wind power and power grid adjustment, the scheduling strategies are given, including unit maintenance scheduling, spinning reserve, energy storage equipment settings by the analysis of the operation characteristics and the response time of thermal power units and hydroelectric units, which can meet the demand of wind power acceptance and provide a solution to improve the level of power grid dispatching.

  10. Anatomic and hemodynamic evaluation of renal venous flow in varicocele formation using color Doppler sonography with emphasis on renal vein entrapment syndrome.

    PubMed

    Unlu, Murat; Orguc, Sebnem; Serter, Selim; Pekindil, Gokhan; Pabuscu, Yuksel

    2007-01-01

    To investigate the anatomic and hemodynamic properties of testicular venous drainage and its effects on varicocele formation and reflux using color Doppler ultrasound (US) with emphasis on renal vein entrapment syndrome. Upper abdominal and scrotal US examinations of 35 varicocele patients and 35 healthy male subjects were performed in the supine position during rest, during a Valsalva maneuver and in the erect position. The aortomesenteric angle and distance (AMA and AMD, respectively), peak mean velocities (PVs) and diameters of different segments of renal veins, testicular vein diameters and duration of flow inversion were measured. In the varicocele group, the lateral segment of the left renal vein (LRV) had a larger diameter and slower PV, and the medial segment of the LRV had a smaller diameter and faster PV. The diameter of the dominant draining vein correlated with the PV of the medial and lateral segments of the LRV, whereas there was no correlation between the diameter of the dominant draining vein and the diameters of the right renal vein (RRV) and the lateral segment of the LRV or the PV of the RRV. The duration of flow inversion correlated with the diameter and PV of the medial segment of the LRV. No correlation between the diameters and PVs of the RRV and the lateral segment of the LRV was detected. The decreases in the AMA, AMD, diameter of the medial segment of the LRV and PV of the lateral segment of the LRV, and the increases in the PV of the medial segment of the LRV and the diameter of the lateral segment of the LRV in varicocele patients in all positions suggest the entrapment or impingement of the left renal vein between the aorta and the superior mesenteric artery. This has been defined as the "nutcracker phenomenon", which is known to affect varicocele formation.

  11. Expanding the first link in the chain of survival - Experiences from dispatcher referral of callers to AED locations.

    PubMed

    Fredman, David; Svensson, Leif; Ban, Yifang; Jonsson, Martin; Hollenberg, Jacob; Nordberg, Per; Ringh, Mattias; Rosenqvist, Mårten; Lundén, Margareta; Claesson, Andreas

    2016-10-01

    Early use of automated external defibrillators (AED) increases survival in cases of out-of-hospital cardiac arrest (OHCA). Dispatchers play important roles in identifying OHCA, dispatching ambulances and providing callers with telephone-assisted cardiopulmonary resuscitation. Guidelines recommend that AED registries be linked to dispatch centres as tools to refer callers to nearby AED. The aim of this study was to investigate to what extent dispatchers, when provided with a tool to display AED locations and accessibility, referred callers to nearby AED. An application providing real-time visualization of AED locations and accessibility was implemented at four dispatch centres in Sweden. Dispatchers were instructed to refer callers to nearby AED when OHCA was suspected. Such cases were prospectively collected, and geographic information systems were used to identify those located ≤100m from an AED. Audio recordings of emergency calls were assessed to evaluate the AED referral rate. Between February and August 2014, 3009 suspected OHCA calls were received. In 6.6% of those calls (200/3009), an AED was ≤100m from the suspected OHCA. The AED was accessible and the caller was not alone on scene in 24% (47/200) of these cases. In two of those 47 cases (4.3%), the dispatcher referred the caller to the AED. Despite a tool for dispatchers to refer callers to a nearby AED, referral was rare. Only a minority of the suspected OHCA cases occurred ≤100m from an AED. We identified AED accessibility and callers being alone on scene as obstacles for AED referral. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Emergency medical dispatch priority in chest pain patients due to life threatening conditions: A cohort study examining circadian variations and impact of the education.

    PubMed

    Rawshani, Araz; Rawshani, Nina; Gelang, Carita; Andersson, Jan-Otto; Larsson, Anna; Bång, Angela; Herlitz, Johan; Gellerstedt, Martin

    2017-06-01

    We examined the accuracy in assessments of emergency dispatchers according to their education and time of the day. We examined this in chest pain patients who were diagnosed with a potentially life-threatening condition (LTC) or died within 30days. Among 2205 persons, 482 died, 1631 experienced an acute coronary syndrome (ACS), 1914 had a LTC. Multivariable logistic regression was used to study how time of the call and the dispatcher's education were associated with the risk of missing to give priority 1 (the highest). Among patients who died, a 7-fold increase in odds of missing to give priority 1 was noted at 1.00pm, as compared with midnight. Compared with assistant nurses, odds ratio for dispatchers with no (medical) training was 0.34 (95% CI 0.14 to 0.77). Among patients with an ACS, odds ratio for calls arriving before lunch was 2.02 (95% CI 1.22 to 3.43), compared with midnight. Compared with assistant nurses, odds ratio for operators with no training was 0.23 (95% CI 0.13 to 0.40). Similar associations were noted for those with any LTC. Dispatcher's education was not associated with the patient's survival. In this group of patients, which experience substantial mortality and morbidity, the risk of not obtaining highest dispatch priority was increased up to 7-fold during lunchtime. Dispatch operators without medical education had the lowest risk, compared with nurses and assistant nurses, of missing to give priority 1, at the expense of lower positive predictive value. What is already known about this subject? Use of the emergency medical service (EMS) increases survival among patients with acute coronary syndromes. It is unknown whether the efficiency - as judged by the ability to identify life-threatening cases among patients with chest pain - varies according to the dispatcher's educational level and the time of day. What does this study add? We provide evidence that the dispatcher's education does not influence survival among patients calling the EMS due to chest discomfort. However, medically educated dispatchers are at greatest risk of missing to identify life-threatening cases, which is explained by more parsimonious use of the highest dispatch priority. We also show that the risk of missing life-threatening cases is at highest around lunch time. How might this impact on clinical practice? Dispatch centers are operated differently all over the world and chest discomfort is one of the most frequent symptoms encountered; we provide evidence that it is safe to operate a dispatch center without medically trained personnel, who actually miss fewer cases of acute coronary syndromes. However, non-medically trained dispatchers consume more pre-hospital resources. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Design description of the Tangaye Village photovoltaic power system

    NASA Astrophysics Data System (ADS)

    Martz, J. E.; Ratajczak, A. F.

    1982-06-01

    The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

  14. Design description of the Tangaye Village photovoltaic power system

    NASA Technical Reports Server (NTRS)

    Martz, J. E.; Ratajczak, A. F.

    1982-01-01

    The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

  15. 14 CFR 121.463 - Aircraft dispatcher qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... aircraft dispatcher for a particular airplane group unless that person has, with respect to an airplane of that group, satisfactorily completed the following: (1) Initial dispatcher training, except that a person who has satisfactorily completed such training for another type airplane of the same group need...

  16. Real-Time Dispatch of Petroleum Tank Trucks.

    DTIC Science & Technology

    1979-12-01

    dispatches for each bulk terminal from which loads are hauled. The dispatchers, located at a central national order processing facility, must each...of an order processor and new capa- bilities to, for instance, trace orders. Also, uniform control of thef order processing function is desirable, if

  17. 14 CFR 121.415 - Crewmember and dispatcher training requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... indoctrination ground training for newly hired crewmembers or dispatchers including 40 programmed hours of... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Crewmember and dispatcher training... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Training Program § 121.415 Crewmember...

  18. Active and Reactive Power Optimal Dispatch Associated with Load and DG Uncertainties in Active Distribution Network

    NASA Astrophysics Data System (ADS)

    Gao, F.; Song, X. H.; Zhang, Y.; Li, J. F.; Zhao, S. S.; Ma, W. Q.; Jia, Z. Y.

    2017-05-01

    In order to reduce the adverse effects of uncertainty on optimal dispatch in active distribution network, an optimal dispatch model based on chance-constrained programming is proposed in this paper. In this model, the active and reactive power of DG can be dispatched at the aim of reducing the operating cost. The effect of operation strategy on the cost can be reflected in the objective which contains the cost of network loss, DG curtailment, DG reactive power ancillary service, and power quality compensation. At the same time, the probabilistic constraints can reflect the operation risk degree. Then the optimal dispatch model is simplified as a series of single stage model which can avoid large variable dimension and improve the convergence speed. And the single stage model is solved using a combination of particle swarm optimization (PSO) and point estimate method (PEM). Finally, the proposed optimal dispatch model and method is verified by the IEEE33 test system.

  19. Influence of dispatching rules on average production lead time for multi-stage production systems.

    PubMed

    Hübl, Alexander; Jodlbauer, Herbert; Altendorfer, Klaus

    2013-08-01

    In this paper the influence of different dispatching rules on the average production lead time is investigated. Two theorems based on covariance between processing time and production lead time are formulated and proved theoretically. Theorem 1 links the average production lead time to the "processing time weighted production lead time" for the multi-stage production systems analytically. The influence of different dispatching rules on average lead time, which is well known from simulation and empirical studies, can be proved theoretically in Theorem 2 for a single stage production system. A simulation study is conducted to gain more insight into the influence of dispatching rules on average production lead time in a multi-stage production system. We find that the "processing time weighted average production lead time" for a multi-stage production system is not invariant of the applied dispatching rule and can be used as a dispatching rule independent indicator for single-stage production systems.

  20. 14 CFR 121.404 - Compliance dates: Crew and dispatcher resource management training.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... approved crew resource management (CRM) or dispatcher resource management (DRM) initial training, as... resource management training. 121.404 Section 121.404 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... § 121.404 Compliance dates: Crew and dispatcher resource management training. After March 19, 1998, no...

  1. 14 CFR 121.687 - Dispatch release: Flag and domestic operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...

  2. 14 CFR 121.687 - Dispatch release: Flag and domestic operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...

  3. 14 CFR 121.687 - Dispatch release: Flag and domestic operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...

  4. 14 CFR 121.687 - Dispatch release: Flag and domestic operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...

  5. 14 CFR 121.687 - Dispatch release: Flag and domestic operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...

  6. 49 CFR 1242.57 - Dispatching trains (account XX-51-58).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Dispatching trains (account XX-51-58). 1242.57 Section 1242.57 Transportation Other Regulations Relating to Transportation (Continued) SURFACE...-Transportation § 1242.57 Dispatching trains (account XX-51-58). Separate common expenses on the basis of train...

  7. 14 CFR 65.61 - Aircraft dispatcher certification courses: Content and minimum hours.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Aircraft dispatcher certification courses: Content and minimum hours. 65.61 Section 65.61 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aircraft dispatcher certification course must: (1) Provide instruction in the areas of knowledge and topics...

  8. 14 CFR 65.61 - Aircraft dispatcher certification courses: Content and minimum hours.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Aircraft dispatcher certification courses: Content and minimum hours. 65.61 Section 65.61 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aircraft dispatcher certification course must: (1) Provide instruction in the areas of knowledge and topics...

  9. Heat Transfer Search Algorithm for Non-convex Economic Dispatch Problems

    NASA Astrophysics Data System (ADS)

    Hazra, Abhik; Das, Saborni; Basu, Mousumi

    2018-06-01

    This paper presents Heat Transfer Search (HTS) algorithm for the non-linear economic dispatch problem. HTS algorithm is based on the law of thermodynamics and heat transfer. The proficiency of the suggested technique has been disclosed on three dissimilar complicated economic dispatch problems with valve point effect; prohibited operating zone; and multiple fuels with valve point effect. Test results acquired from the suggested technique for the economic dispatch problem have been fitted to that acquired from other stated evolutionary techniques. It has been observed that the suggested HTS carry out superior solutions.

  10. Heat Transfer Search Algorithm for Non-convex Economic Dispatch Problems

    NASA Astrophysics Data System (ADS)

    Hazra, Abhik; Das, Saborni; Basu, Mousumi

    2018-03-01

    This paper presents Heat Transfer Search (HTS) algorithm for the non-linear economic dispatch problem. HTS algorithm is based on the law of thermodynamics and heat transfer. The proficiency of the suggested technique has been disclosed on three dissimilar complicated economic dispatch problems with valve point effect; prohibited operating zone; and multiple fuels with valve point effect. Test results acquired from the suggested technique for the economic dispatch problem have been fitted to that acquired from other stated evolutionary techniques. It has been observed that the suggested HTS carry out superior solutions.

  11. A priority dispatch system for emergency medical services.

    PubMed

    Slovis, C M; Carruth, T B; Seitz, W J; Thomas, C M; Elsea, W R

    1985-11-01

    A decision tree priority dispatch system for emergency medical services (EMS) was developed and implemented in Atlanta and Fulton County, Georgia. The dispatch system shortened the average response time from 14.2 minutes to 10.4 minutes for the 30% of patients deemed most urgent (P less than or equal to .05); resulted in a significant increase in the use of advanced life support units for this group (P less than or equal to .02); decreased the number of calls that required a backup ambulance service; and significantly increased conformity to national EMS response time standards for critically ill and injured patients (P less than or equal to .0009). Due to dispatch error, 0.3% of calls were dispatched as least severe but subsequently were found to be most urgent.

  12. Dramatic Demand Reduction In The Desert Southwest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boehm, Robert; Hsieh, Sean; Lee, Joon

    This report summarizes a project that was funded to the University of Nevada Las Vegas (UNLV), with subcontractors Pulte Homes and NV Energy. The project was motivated by the fact that locations in the Desert Southwest portion of the US demonstrate very high peak electrical demands, typically in the late afternoons in the summer. These high demands often require high priced power to supply the needs, and the large loads can cause grid supply problems. An approach was proposed through this contact that would reduce the peak electrical demands to an anticipated 65% of what code-built houses of the similarmore » size would have. It was proposed to achieve energy reduction through four approaches applied to a development of 185 homes in northwest part of Las Vegas named Villa Trieste. First, the homes would all be highly energy efficient. Secondly, each house would have a PV array installed on it. Third, an advanced demand response technique would be developed to allow the resident to have some control over the energy used. Finally, some type of battery storage would be used in the project. Pulte Homes designed the houses. The company considered initial cost vs. long-term savings and chose options that had relatively short paybacks. HERS (Home Energy Rating Service) ratings for the homes are approximately 43 on this scale. On this scale, code-built homes rate at 100, zero energy homes rate a 0, and Energy Star homes are 85. In addition a 1.764 Wp (peak Watt) rated PV array was used on each house. This was made up of solar shakes that were in visual harmony with the roofing material used. A demand response tool was developed to control the amount of electricity used during times of peak demand. While demand response techniques have been used in the utility industry for some time, this particular approach is designed to allow the customer to decide the degree of participation in the response activity. The temperature change in the residence can be decided by the residents by adjusting settings. In a sense the customer can choose between greater comfort and greater money savings during demand response circumstances. Finally a battery application was to be considered. Initially it was thought that a large battery (probably a sodium-sulfur type) would be installed. However, after the contract was awarded, it was determined that a single, centrally-located battery system would not be appropriate for many reasons, including that with the build out plan there would not be any location to put it. The price had risen substantially since the budget for the project was put together. Also, that type of battery has to be kept hot all the time, but its use was only sought for summer operation. Hence, individual house batteries would be used, and these are discussed at the end of this report. Many aspects of the energy use for climate control in selected houses were monitored before residents moved in. This was done both to understand the magnitude of the energy flows but also to have data that could be compared to the computer simulations. The latter would be used to evaluate various aspects of our plan. It was found that good agreement existed between actual energy use and computed energy use. Hence, various studies were performed via simulations. Performance simulations showed the impact on peak energy usage between a code built house of same size and shape compared to the Villa Trieste homes with and without the PV arrays on the latter. Computations were also used to understand the effect of varying orientations of the houses in this typical housing development, including the effect of PV electrical generation. Energy conservation features of the Villa Trieste homes decreased the energy use during peak times (as well as all others), but the resulting decreased peak occurred at about the same time as the code-built houses. Consideration of the PV generation decreases the grid energy use further during daylight hours, but did not extend long enough many days to decrease the peak. Hence, a demand response approach, as planned, was needed. With participation of the residents in the demand response program developed does enable the houses to reduce the peak demand between 66% and 72%, depending on the built years. This was addressed fully in the latter part the study and is described in the latter part of this report.« less

  13. The Energy Imperative: Report Update

    DTIC Science & Technology

    2008-11-01

    projections for 2030.2 • Renewable power generation from solar , wind, biomass, and geothermal resources is growing rapidly, but these sources still...consistent policy approach to address cost, regulatory, and transmission infrastructure challenges. For solar photovoltaic (PV) technology, basic...research is particularly important to make the needed improvements in cost and performance. • Solar power can help meet peak load electricity demand

  14. Photovoltaic technology for sustainability: An investigation of the distributed utility concept as a policy framework

    NASA Astrophysics Data System (ADS)

    Letendre, Steven Emery

    The U.S. electric utility sector in its current configuration is unsustainable. The majority of electricity in the United States is produced using finite fossil fuels. In addition, significant potential exists to improve the nation's efficient use of energy. A sustainable electric utility sector will be characterized by increased use of renewable energy sources and high levels of end-use efficiency. This dissertation analyzes two alternative policy approaches designed to move the U.S. electric utility sector toward sustainability. One approach is labeled incremental which involves maintaining the centralized structure of the electric utility sector but facilitating the introduction of renewable energy and efficiency into the electrical system through the pricing mechanism. A second policy approach was described in which structural changes are encouraged based on the emerging distributed utility (DU) concept. A structural policy orientation attempts to capture the unique localized benefits that distributed renewable resources and energy efficiency offer to electric utility companies and their customers. A market penetration analysis of PV in centralized energy supply and distributed peak-shaving applications is conducted for a case-study electric utility company. Sensitivity analysis was performed based on incremental and structural policy orientations. The analysis provides compelling evidence which suggests that policies designed to bring about structural change in the electric utility sector are needed to move the industry toward sustainability. Specifically, the analysis demonstrates that PV technology, a key renewable energy option likely to play an important role in a renewable energy future, will begin to penetrate the electrical system in distributed peak-shaving applications long before the technology is introduced as a centralized energy supply option. Most policies to date, which I term incremental, attempt to encourage energy efficiency and renewables through the pricing system. Based on past policy experience, it is unlikely that such an approach would allow PV to compete in Delaware as an energy supply option in the next ten to twenty years. Alternatively, a market-based, or green pricing, approach will not create significant market opportunities for PV as a centralized energy supply option. However, structural policies designed to encourage the explicit recognition of the localized benefits of distributed resources could result in PV being introduced into the electrical system early in the next century.

  15. Improving the Signal-To-Noise Ratio When Monitoring Countermovement Jump Performance.

    PubMed

    Kennedy, Rodney A; Drake, David

    2018-05-08

    Kennedy, RA and Drake, D. Improving the signal-to-noise ratio when monitoring countermovement jump performance. J Strength Cond Res XX(X): 000-000, 2018-Countermovement jump (CMJ) performance has been routinely used to monitor neuromuscular status. However, the protocol used to establish the criterion score is not well documented. The purpose of this study was to examine how the protocol used would influence of the sensitivity of CMJ variables in rugby union players. Fifteen male (age: 19.7 ± 0.5 years) rugby union players performed 8 CMJs on 2 occasions, separated by 7 days. The between-session coefficient of variation (CV) was calculated using 2 techniques for treating multiple trials, the average, and the trial with the best jump height (JH), and then compared with the smallest worthwhile change (SWC). The signal-to-noise ratio was measured as the group mean change in a variable divided by the CV. Using the average value across multiple trials is superior to the best trial method, based on lower CVs for all variables. Only the average performance across 6 or more trials was classified as ideal (CV < 0.5 × SWC) for peak velocity (PV). In addition, the signal-to-noise ratio for peak concentric power (PCP), PV, and JH were classified as good, irrespective of the treatment method. Although increasing the number of trials can reduce the random error, it may be pragmatic to simply take the average from 2 to 3 trials, facilitating a CV < SWC for PV, PCP, and JH. Due to its simplicity, JH may be considered the principal variable to monitor neuromuscular fatigue.

  16. 77 FR 64977 - Texas Dispatchable Wind 1, LLC; Supplemental Notice That Initial Market-Based Rate Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-24

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-70-000] Texas Dispatchable Wind 1, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Texas Dispatchable Wind 1 LLC's application for market-based rate authority, with an accompanying rate...

  17. Information needs for increasing log transport efficiency

    Treesearch

    Timothy P. McDonald; Steven E. Taylor; Robert B. Rummer; Jorge Valenzuela

    2001-01-01

    Three methods of dispatching trucks to loggers were tested using a log transport simulation model: random allocation, fixed assignment of trucks to loggers, and dispatch based on knowledge of the current status of trucks and loggers within the system. This 'informed' dispatch algorithm attempted to minimize the difference in time between when a logger would...

  18. 14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...

  19. 14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...

  20. 14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...

  1. 14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...

  2. 14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...

  3. 77 FR 12104 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ... Courses AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and request for comments... certification and approval of aircraft dispatcher courses. The FAA uses the information to ensure compliance and..., Subpart C, Aircraft Dispatchers and App. A Aircraft Dispatcher Courses. Form Numbers: There are no FAA...

  4. VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITEWIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITE-WIDE FIRE ALARM SIGNALS, INCLUDING ALL FIRE PHONES, FIRE PULL BOXES, HEAT AND SMOKE DETECTORS, AND SUPPRESSION SYSTEM FLOW ALARMS, ARE TRANSMITTED TO THE BUILDING 331 DISPATCHER'S OFFICE. (3/77) - Rocky Flats Plant, Vehicle Maintenance Garage & Fire Station, Golden, Jefferson County, CO

  5. Uncertainties that flight crews and dispatchers must consider when calculating the fuel needed for a flight

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    1996-01-01

    In 1993, fuel accounted for approximately 15 percent of an airline's expenses. Fuel consumption increases as fuel reserves increase because of the added weight to the aircraft. Calculating fuel reserves is a function of Federal Aviation Regulations, airline company policy, and factors that impact or are impacted by fuel usage enroute. This research studied how pilots and dispatchers determined the fuel needed for a flight and identified areas where improvements in methods may yield measurable fuel savings by (1) listing the uncertainties that contribute to adding contingency fuel, (2) obtaining the pilots' and dispatchers' perspective on how often each uncertainty occurred, and (3) obtaining pilots' and dispatchers' perspective on the fuel used for each occurrence. This study found that for the majority of the time, pilots felt that dispatchers included enough fuel. As for the uncertainties that flight crews and dispatchers account for, air traffic control accounts for 28% and weather uncertainties account for 58 percent. If improvements can be made in these two areas, a great potential exists to decrease the reserve required, and therefore, fuel usage without jeopardizing safety.

  6. Registered nurses' experiences of their decision-making at an Emergency Medical Dispatch Centre.

    PubMed

    Ek, Bosse; Svedlund, Marianne

    2015-04-01

    To describe registered nurses' experiences at an Emergency Medical Dispatch Centre. It is important that ambulances are urgently directed to patients who are in need of immediate help and of quick transportation to a hospital. Because resources are limited, Emergency Medical Dispatch centres cannot send ambulances with high priority to all callers. The efficiency of the system is therefore dependent on triage. Nurses worldwide are involved in patient triage, both before the patient's arrival to the hospital and in the subsequent emergency care. Ambulance dispatching is traditionally a duty for operators at Emergency Medical Dispatch centres, and in Sweden this duty has become increasingly performed by registered nurses. A qualitative design was used for this study. Fifteen registered nurses with experience at Emergency Medical Dispatch centres were interviewed. The participants were asked to describe the content of their work and their experiences. They also described the most challenging and difficult situations according to the critical incidence technique. Content analysis was used. Two themes emerged during the analysis: 'Having a profession with opportunities and obstacles' and 'Meeting serious and difficult situations', with eight sub-themes. The results showed that the decisions to dispatch ambulances were both challenging and difficult. Difficulties included conveying medical advice without seeing the patient, teaching cardio-pulmonary resuscitation via telephone and dealing with intoxicated and aggressive callers. Conflicts with colleagues and ambulance crews as well as fear of making wrong decisions were also mentioned. Work at Emergency Medical Dispatch centres is a demanding but stimulating duty for registered nurses. Great benefits can be achieved using experienced triage nurses, including increased patient safety and better use of medical resources. Improved internal support systems at Emergency Medical Dispatch centres and striving for a blame-free culture are important factors to attract and retain employees. © 2014 John Wiley & Sons Ltd.

  7. Evaluation of stress stabilities in amorphous In-Ga-Zn-O thin-film transistors: Effect of passivation with Si-based resin

    NASA Astrophysics Data System (ADS)

    Ochi, Mototaka; Hino, Aya; Goto, Hiroshi; Hayashi, Kazushi; Fujii, Mami N.; Uraoka, Yukiharu; Kugimiya, Toshihiro

    2018-02-01

    Fabrication process conditions of a passivation (PV) layer correlated with stress stabilities of amorphous In-Ga-Zn-O (a-IGZO) thin-film transistors (TFTs). In etch-stop layer (ESL)-TFTs, by inserting a Si-based resin between SiN x and SiO x PV layers, the peak intensity in the photoinduced transient spectroscopy (PITS) spectrum was notably reduced. This suggested the suppression of hydrogen incorporation into a-IGZO, which led to the improvement of stability under negative bias thermal illumination stress (NBTIS). In contrast, the hydrogen-related defects in the a-IGZO were easily formed by the back-channel etch (BCE) process. Furthermore, it was found that, under NBTIS, the transfer curves of the BCE-TFTs shifted in parallel owing to the positive fixed charge located in the back channel of the a-IGZO TFTs. The hump-shaped shift increased with stress time. This is because hydrogen atoms located at the back-channel surfaces of the a-IGZO and/or PV layers were incorporated into the channel region of the BCE-TFTs and induced the hydrogen-related defects.

  8. Dynamic Price Vector Formation Model-Based Automatic Demand Response Strategy for PV-Assisted EV Charging Stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Qifang; Wang, Fei; Hodge, Bri-Mathias

    A real-time price (RTP)-based automatic demand response (ADR) strategy for PV-assisted electric vehicle (EV) Charging Station (PVCS) without vehicle to grid is proposed. The charging process is modeled as a dynamic linear program instead of the normal day-ahead and real-time regulation strategy, to capture the advantages of both global and real-time optimization. Different from conventional price forecasting algorithms, a dynamic price vector formation model is proposed based on a clustering algorithm to form an RTP vector for a particular day. A dynamic feasible energy demand region (DFEDR) model considering grid voltage profiles is designed to calculate the lower and uppermore » bounds. A deduction method is proposed to deal with the unknown information of future intervals, such as the actual stochastic arrival and departure times of EVs, which make the DFEDR model suitable for global optimization. Finally, both the comparative cases articulate the advantages of the developed methods and the validity in reducing electricity costs, mitigating peak charging demand, and improving PV self-consumption of the proposed strategy are verified through simulation scenarios.« less

  9. Recommendations in dispatcher-assisted bystander resuscitation from emergency call center.

    PubMed

    García del Águila, J; López-Messa, J; Rosell-Ortiz, F; de Elías Hernández, R; Martínez del Valle, M; Sánchez-Santos, L; López-Herce, J; Cerdà-Vila, M; Roza-Alonso, C L; Bernardez-Otero, M

    2015-01-01

    Dispatch-assisted bystander cardiopulmonary resuscitation in out-of-hospital cardiac arrest has been shown as an effective measure to improve the survival of this process. The development of a unified protocol for all dispatch centers of the different emergency medical services can be a first step towards this goal in our environment. The process of developing a recommendations document and the realization of posters of dispatch-assisted cardiopulmonary resuscitation, agreed by different actors and promoted by the Spanish Resuscitation Council, is presented. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  10. Analysis of a utility-interactive wind-photovoltaic hybrid system with battery storage using neural network

    NASA Astrophysics Data System (ADS)

    Giraud, Francois

    1999-10-01

    This dissertation investigates the application of neural network theory to the analysis of a 4-kW Utility-interactive Wind-Photovoltaic System (WPS) with battery storage. The hybrid system comprises a 2.5-kW photovoltaic generator and a 1.5-kW wind turbine. The wind power generator produces power at variable speed and variable frequency (VSVF). The wind energy is converted into dc power by a controlled, tree-phase, full-wave, bridge rectifier. The PV power is maximized by a Maximum Power Point Tracker (MPPT), a dc-to-dc chopper, switching at a frequency of 45 kHz. The whole dc power of both subsystems is stored in the battery bank or conditioned by a single-phase self-commutated inverter to be sold to the utility at a predetermined amount. First, the PV is modeled using Artificial Neural Network (ANN). To reduce model uncertainty, the open-circuit voltage VOC and the short-circuit current ISC of the PV are chosen as model input variables of the ANN. These input variables have the advantage of incorporating the effects of the quantifiable and non-quantifiable environmental variants affecting the PV power. Then, a simplified way to predict accurately the dynamic responses of the grid-linked WPS to gusty winds using a Recurrent Neural Network (RNN) is investigated. The RNN is a single-output feedforward backpropagation network with external feedback, which allows past responses to be fed back to the network input. In the third step, a Radial Basis Functions (RBF) Network is used to analyze the effects of clouds on the Utility-Interactive WPS. Using the irradiance as input signal, the network models the effects of random cloud movement on the output current, the output voltage, the output power of the PV system, as well as the electrical output variables of the grid-linked inverter. Fourthly, using RNN, the combined effects of a random cloud and a wind gusts on the system are analyzed. For short period intervals, the wind speed and the solar radiation are considered as the sole sources of power, whose variations influence the system variables. Since both subsystems have different dynamics, their respective responses are expected to impact differently the whole system behavior. The dispatchability of the battery-supported system as well as its stability and reliability during gusts and/or cloud passage is also discussed. In the fifth step, the goal is to determine to what extent the overall power quality of the grid would be affected by a proliferation of Utility-interactive hybrid system and whether recourse to bulky or individual filtering and voltage controller is necessary. The final stage of the research includes a steady-state analysis of two-year operation (May 96--Apr 98) of the system, with a discussion on system reliability, on any loss of supply probability, and on the effects of the randomness in the wind and solar radiation upon the system design optimization.

  11. Dispatchable Solar Power Plant Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Henry

    As penetration of intermittent renewable power increases, grid operators must manage greater variability in the supply and demand on the grid. One result is that utilities are planning to build many new natural gas peaking power plants that provide added flexibility needed for grid management. This report discusses the development of a dispatchable solar power (DSP) plant that can be used in place of natural gas peakers. Specifically, a new molten-salt tower (MST) plant has been developed that is designed to allow much more flexible operation than typically considered in concentrating solar power plants. As a result, this plant canmore » provide most of the capacity and ancillary benefits of a conventional natural gas peaker plant but without the carbon emissions. The DSP system presented was designed to meet the specific needs of the Arizona Public Service (APS) utility 2017 peaking capacity request for proposals (RFP). The goal of the effort was to design a MST peaker plant that had the operational capabilities required to meet the peaking requirements of the utility and be cost competitive with the natural gas alternative. The effort also addresses many perceived barriers facing the commercial deployment of MST technology in the US today. These include MST project development issues such as permitting, avian impacts, visual impacts of tower CSP projects, project schedule, and water consumption. The DSP plant design is based on considerable analyses using sophisticated solar system design tools and in-depth preliminary engineering design. The resulting DSP plant design uses a 250 MW steam power cycle, with solar field designed to fit on a square mile plot of land that has a design point thermal rating of 400 MWt. The DSP plant has an annual capacity factor of about 16% tailored to deliver greater than 90% capacity during the critical Arizona summer afternoon peak. The table below compares the All-In energy cost and capacity payment of conventional combustion turbines to DSP plants. These results estimate that the cost of the DSP plant is about 10% higher than a similarly-sized and operated frame combustion turbine and slightly cheaper than an aero derivative combustion turbine when APS reference fuel and emissions costs are included. The DSP plant cost is based on a single, first-of-a-kind plant, and it is likely that subsequent plants would be less expensive.« less

  12. Barriers to dispatcher-assisted cardiopulmonary resuscitation in Singapore.

    PubMed

    Ho, Andrew Fu Wah; Sim, Zariel Jiaying; Shahidah, Nur; Hao, Ying; Ng, Yih Yng; Leong, Benjamin S H; Zarinah, Siti; Teo, Winston K L; Goh, Geraldine Shu Yi; Jaafar, Hamizah; Ong, Marcus E H

    2016-08-01

    Dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) is effective in increasing bystander CPR in out-of-hospital cardiac arrests (OHCA). Singapore has recently implemented a DA-CPR program. We aimed to characterize barriers to commencement of chest compressions by callers in Singapore. We analyzed dispatch recordings of OHCA cases received by the ambulance call center between July 2012 and March 2015. Audio recordings of poor quality were excluded. Trained reviewers noted the sequential stages of the dispatcher's recognition of CPR, delivering CPR instructions and caller performing CPR. Time taken to reach these milestones was noted. Barriers to chest compressions were identified. A total of 4897 OHCA occurred during the study period, overall bystander CPR rate was 45.7%. 1885 dispatch recordings were reviewed with 1157 cases qualified for dispatcher CPR. In 1128 (97.5%) cases, the dispatcher correctly recognized the need for CPR. CPR instructions were delivered in 1056 (91.3%) cases. Of these, 1007 (87.0%) callers performed CPR to instruction. One or more barriers to chest compressions were identified in 430 (37.2%) cases. The commonest barrier identified was "could not move patient" (27%). Cases where barriers were identified were less likely to have the need for CPR recognized by the dispatcher (94.9% vs. 99.0%, p<0.001), CPR instructions given (79.3% vs. 98.3%, p<0.001) and CPR started (67.9% vs. 98.3%, p<0.001), while the time taken to reach each of these stages were significantly longer (p<0.001). Barriers were present in 37% of cases. They were associated with lower proportion of CPR started and longer delay to CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. A Hybrid Genetic Programming Algorithm for Automated Design of Dispatching Rules.

    PubMed

    Nguyen, Su; Mei, Yi; Xue, Bing; Zhang, Mengjie

    2018-06-04

    Designing effective dispatching rules for production systems is a difficult and timeconsuming task if it is done manually. In the last decade, the growth of computing power, advanced machine learning, and optimisation techniques has made the automated design of dispatching rules possible and automatically discovered rules are competitive or outperform existing rules developed by researchers. Genetic programming is one of the most popular approaches to discovering dispatching rules in the literature, especially for complex production systems. However, the large heuristic search space may restrict genetic programming from finding near optimal dispatching rules. This paper develops a new hybrid genetic programming algorithm for dynamic job shop scheduling based on a new representation, a new local search heuristic, and efficient fitness evaluators. Experiments show that the new method is effective regarding the quality of evolved rules. Moreover, evolved rules are also significantly smaller and contain more relevant attributes.

  14. Modeling and Simulation of Bus Dispatching Policy for Timed Transfers on Signalized Networks

    NASA Astrophysics Data System (ADS)

    Cho, Hsun-Jung; Lin, Guey-Shii

    2007-12-01

    The major work of this study is to formulate the system cost functions and to integrate the bus dispatching policy with signal control. The integrated model mainly includes the flow dispersion model for links, signal control model for nodes, and dispatching control model for transfer terminals. All such models are inter-related for transfer operations in one-center transit network. The integrated model that combines dispatching policies with flexible signal control modes can be applied to assess the effectiveness of transfer operations. It is found that, if bus arrival information is reliable, an early dispatching decision made at the mean bus arrival times is preferable. The costs for coordinated operations with slack times are relatively low at the optimal common headway when applying adaptive route control. Based on such findings, a threshold function of bus headway for justifying an adaptive signal route control under various time values of auto drivers is developed.

  15. Hypervolemia During Drinking of ISO and Hypertonic Fluids by Men at Rest and Exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Looft-Wilson, R.; Wisherd, J. L.; Fung, P. P.; Erti, A. C.; Jackson, C. G. R.; Barnes, P. R.; Wong, L. G.

    1994-01-01

    To test the hypothesis that drink composition is more important than osmolality (osm) for maintaining and increasing plasma vol. (PV, hypervolemia) at rest and exercise (21.8C Tdb, 50% rh), 6 men (22-39 vr) underwent six treatments while sitting for 90 min (0.39 l/min) followed by 70 min of sitting ergometer exercise (2.08 l/min, 70%vO2 peak). Resting, intermittent drinking (10 ml/kg, 768 ml) beverages were: P1 (20 mEq Na+, 365 mosmol/kg), P2 (40 mEq Na+. 791 mosm), P2G (40 mEq Na+, 80 ml glycerol, 1.392 mosm). AA (157 mEq Na+, 253 mosm), and 01 and 02 (nothing). The exercise drink (10 ml/kg, 768 ml) was P1 for all experiments, except 02 (nothing). Resting % delta PV (Hb-Hct) increased (P<0.05) by 3-6% only with P2 and AA, respectively, Exercise % delta PV was + 1 to + 3% (NS) with AA, -6% to 0% (KS) with P1, P2. P2G, and 01,and 8% to -5% (P<0.05) with 02- Thus, AA with 157 mEq Na+ and the lowest osmolality maintained PV at rest and exercise, while the other beverages with low Na+ and higher osmolality (365 to 1.382 mosm) did not.

  16. Solar thermoelectricity via advanced latent heat storage: A cost-effective small-scale CSP application

    NASA Astrophysics Data System (ADS)

    Glatzmaier, G. C.; Rea, J.; Olsen, M. L.; Oshman, C.; Hardin, C.; Alleman, J.; Sharp, J.; Weigand, R.; Campo, D.; Hoeschele, G.; Parilla, P. A.; Siegel, N. P.; Toberer, E. S.; Ginley, D. S.

    2017-06-01

    We are developing a novel concentrating solar electricity-generating technology that is both modular and dispatchable. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) uses concentrated solar flux to generate high-temperature thermal energy, which directly converts to electricity via thermoelectric generators (TEGs), stored within a phase-change material (PCM) for electricity generation at a later time, or both allowing for simultaneous charging of the PCM and electricity generation. STEALS has inherent features that drive its cost-competitive scale to be much smaller than current commercial concentrating solar power (CSP) plants. Most obvious is modularity of the solid-state TEG, which favors smaller scales in the kilowatt range as compared to CSP steam turbines, which are minimally 50 MWe for commercial power plants. Here, we present techno-economic and market analyses that show STEALS can be a cost-effective electricity-generating technology with particular appeal to small-scale microgrid applications. We evaluated levelized cost of energy (LCOE) for STEALS and for a comparable photovoltaic (PV) system with battery storage. For STEALS, we estimated capital costs and the LCOE as functions of the type of PCM including the use of recycled aluminum alloys, and evaluated the cost tradeoffs between plasma spray coatings and solution-based boron coatings that are applied to the wetted surfaces of the PCM subsystem. We developed a probabilistic cost model that accounts for uncertainties in the cost and performance inputs to the LCOE estimation. Our probabilistic model estimated LCOE for a 100-kWe STEALS system that had 5 hours of thermal storage and 8-10 hours of total daily power generation. For these cases, the solar multiple for the heliostat field varied between 1.12 and 1.5. We identified microgrids as a likely market for the STEALS system. We characterized microgrid markets in terms of nominal power, dispatchability, geographic location, and customer type, and specified additional features for STEALS that are needed to meet the needs of this growing power market.

  17. Influence of Distributed Residential Energy Storage on Voltage in Rural Distribution Network and Capacity Configuration

    NASA Astrophysics Data System (ADS)

    Liu, Lu; Tong, Yibin; Zhao, Zhigang; Zhang, Xuefen

    2018-03-01

    Large-scale access of distributed residential photovoltaic (PV) in rural areas has solved the voltage problem to a certain extent. However, due to the intermittency of PV and the particularity of rural residents’ power load, the problem of low voltage in the evening peak remains to be resolved. This paper proposes to solve the problem by accessing residential energy storage. Firstly, the influence of access location and capacity of energy storage on voltage distribution in rural distribution network is analyzed. Secondly, the relation between the storage capacity and load capacity is deduced for four typical load and energy storage cases when the voltage deviation meets the demand. Finally, the optimal storage position and capacity are obtained by using PSO and power flow simulation.

  18. Automatic low-order aberration correction based on geometrical optics for slab lasers.

    PubMed

    Yu, Xin; Dong, Lizhi; Lai, Boheng; Yang, Ping; Liu, Yong; Kong, Qingfeng; Yang, Kangjian; Tang, Guomao; Xu, Bing

    2017-02-20

    In this paper, we present a method based on geometry optics to simultaneously correct low-order aberrations and reshape the beams of slab lasers. A coaxial optical system with three lenses is adapted. The positions of the three lenses are directly calculated based on the beam parameters detected by wavefront sensors. The initial sizes of the input beams are 1.8  mm×11  mm, and peak-to-valley (PV) values of the wavefront range up to several tens of microns. After automatic correction, the dimensions may reach nearly 22  mm×22  mm as expected, and PV values of the wavefront are less than 2 μm. The effectiveness and precision of this method are verified with experiments.

  19. View west of load dispatch model board; section covers substations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west of load dispatch model board; section covers substations from edgerly (right) to thorndale and west yard (left). Instruments at bottom of center board section formerly monitored energy usage and were replaced by a computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  20. Information processing in an urban fire department communication system.

    PubMed

    Siegel, J; Weitzman, D O

    1975-09-01

    One of the most important functions of any fire department is to provide selective contact with fire fighting units and to dispatch these units based on information gathered from street alarm boxes and telephones. This paper is concerned with the problem of dispatching tactical response information to remote fire fighting units and with the effect of workload on the dispatch function.

  1. Real-time OHT Dispatching Mechanism for the Interbay Automated Material Handling System with Shortcuts and Bypasses

    NASA Astrophysics Data System (ADS)

    Pan, Cong; Zhang, Jie; Qin, Wei

    2017-05-01

    As a key to improve the performance of the interbay automated material handling system (AMHS) in 300 mm semiconductor wafer fabrication system, the real-time overhead hoist transport (OHT) dispatching problem has received much attention. This problem is first formulated as a special form of assignment problem and it is proved that more than one solution will be obtained by Hungarian algorithm simultaneously. Through proposing and strictly proving two propositions related to the characteristics of these solutions, a modified Hungarian algorithm is designed to distinguish these solutions. Finally, a new real-time OHT dispatching method is carefully designed by implementing the solution obtained by the modified Hungarian algorithm. The experimental results of discrete event simulations show that, compared with conventional Hungarian algorithm dispatching method, the proposed dispatching method that chooses the solution with the maximum variance respectively reduces on average 4 s of the average waiting time and average lead time of wafer lots, and its performance is rather stable in multiple different scenarios of the interbay AMHS with different quantities of shortcuts. This research provides an efficient real-time OHT dispatching mechanism for the interbay AMHS with shortcuts and bypasses.

  2. Do emergency medical services dispatch nature and severity codes agree with paramedic field findings?

    PubMed

    Neely, K W; Eldurkar, J A; Drake, M E

    2000-02-01

    Emergency medical services (EMS) systems increasingly seek to triage patients to alternative EMS resources. Emergency medical services dispatchers may be asked to perform this triage. New protocols may be necessary. Alternatively, existing protocols may be sufficient for this task. For an existing dispatch protocol to be sufficient, it at least must accurately categorize patient condition and severity based on an external standard. To examine the extent to which nature codes (NCs), or patient condition codes, and severity codes (SCs) currently assigned in one urban 911 center agree with paramedic field findings. The null hypothesis was that there is no routine agreement (75%) between dispatcher-assigned NC or SC and paramedic-assigned NC or SC for the same patient using the same protocol. Emergency medical services dispatch nature and severity code data and matching out-of-hospital data were prospectively gathered over six months. Dispatch data included the NC: caller-identified problem, and the SC: dispatcher-assessed severity. Each NC is modified by one of three SCs (1, 3, or 9): 1 is emergent, 3 is urgent, and 9 is neither. Paramedics verified and/or corrected dispatcher-assigned NCs and SCs using the same dispatch protocol. One thousand forty usable cases fell into 33 unique NC/SC combinations. The designation of SC 1 was assigned 275 times, SC 3 was assigned 736 times, and SC 9 was assigned 24 times. The SC was missing five times. The overall NC agreement was 0.70 (95% CI = 0.697 to 0.703). The overall SC agreement was 0.65 (95% CI = 0.645 to 0.655). The NC agreement exceeded 75% for ten (59%) NC/SC combinations. The SC agreement exceeded 75% for five (29%) NC/SC combinations. There was both NC and SC agreement for four (24%) combinations: urgent breathing problems, urgent diabetic problems, urgent falls, and urgent overdoses. The greatest NC/SC disagreement occurred within emergent and urgent traffic crashes. Paramedics adjusted SC toward lower severity 29% of the time and toward higher severity 5.4% of the time. There was no upward SC adjustment for eight (47%) combinations. Certain dispatcher-assigned NC and SC codes and NC/SC combinations achieved the study threshold. Overall agreement failed to achieve the threshold. The lowest SC level was rarely assigned, preventing a meaningful analysis of all severity levels.

  3. Hospital-Confirmed Acute Myocardial Infarction: Prehospital Identification Using the Medical Priority Dispatch System.

    PubMed

    Clawson, Jeff J; Gardett, Isabel; Scott, Greg; Fivaz, Conrad; Barron, Tracey; Broadbent, Meghan; Olola, Christopher

    2018-02-01

    Introduction Early recognition of an acute myocardial infarction (AMI) can increase the patient's likelihood of survival. As the first point of contact for patients accessing medical care through emergency services, emergency medical dispatchers (EMDs) represent the earliest potential identification point for AMIs. The objective of the study was to determine how AMI cases were coded and prioritized at the dispatch point, and also to describe the distribution of these cases by patient age and gender. Hypothesis/Problem No studies currently exist that describe the EMD's ability to correctly triage AMIs into Advanced Life Support (ALS) response tiers. The retrospective descriptive study utilized data from three sources: emergency medical dispatch, Emergency Medical Services (EMS), and emergency departments (EDs)/hospitals. The primary outcome measure was the distributions of AMI cases, as categorized by Chief Complaint Protocol, dispatch priority code and level, and patient age and gender. The EMS and ED/hospital data came from the Utah Department of Health (UDoH), Salt Lake City, Utah. Dispatch data came from two emergency communication centers covering the entirety of Salt Lake City and Salt Lake County, Utah. Overall, 89.9% of all the AMIs (n=606) were coded in one of the three highest dispatch priority levels, all of which call for ALS response (called CHARLIE, DELTA, and ECHO in the studied system). The percentage of AMIs significantly increased for patients aged 35 years and older, and varied significantly by gender, dispatch level, and chief complaint. A total of 85.7% of all deaths occurred among patients aged 55 years and older, and 88.9% of the deaths were handled in the ALS-recommended priority levels. Acute myocardial infarctions may present as a variety of clinical symptoms, and the study findings demonstrated that more than one-half were identified as having chief complaints of Chest Pain or Breathing Problems at the dispatch point, followed by Sick Person and Unconscious/Fainting. The 35-year age cutoff for assignment to higher priority levels is strongly supported. The Falls and Sick Person Protocols offer opportunities to capture atypical AMI presentations. Clawson JJ , Gardett I , Scott G , Fivaz C , Barron T , Broadbent M , Olola C . Hospital-confirmed acute myocardial infarction: prehospital identification using the Medical Priority Dispatch System. Prehosp Disaster Med. 2018;33(1):29-35.

  4. Study of Flexible Load Dispatch to Improve the Capacity of Wind Power Absorption

    NASA Astrophysics Data System (ADS)

    Yunlei, Yang; Shifeng, Zhang; Xiao, Chang; Da, Lei; Min, Zhang; Jinhao, Wang; Shengwen, Li; Huipeng, Li

    2017-05-01

    The dispatch method which track the trend of load demand by arranging the generation scheme of controllable hydro or thermal units faces great difficulties and challenges. With the increase of renewable energy sources such as wind power and photovoltaic power introduced to grid, system has to arrange much more spinning reserve units to compensate the unbalanced power. How to exploit the peak-shaving potential of flexible load which can be shifted with time or storage energy has become many scholars’ research direction. However, the modelling of different kinds of load and control strategy is considerably difficult, this paper choose the Air Conditioner with compressor which can storage energy in fact to study. The equivalent thermal parameters of Air Conditioner has been established. And with the use of “loop control” strategies, we can predict the regulated power of Air Conditioner. Then we established the Gen-Load optimal scheduling model including flexible load based on traditional optimal scheduling model. At last, an improved IEEE-30 case is used to verify. The result of simulation shows that flexible load can fast-track renewable power changes. More than that, with flexible load and reasonable incentive method to consumers, the operating cost of the system can be greatly cut down.

  5. Emissions implications of downscaled electricity generation scenarios for the western United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nsanzineza, Rene; O’Connell, Matthew; Brinkman, Gregory

    This study explores how emissions from electricity generation in the Western Interconnection region of the U.S. might respond in circa 2030 to contrasting scenarios for fuel prices and greenhouse gas (GHG) emissions fees. We examine spatial and temporal variations in generation mix across the region and year using the PLEXOS unit commitment and dispatch model with a production cost model database adapted from the Western Electricity Coordinating Council. Emissions estimates are computed by combining the dispatch model results with unit-specific, emissions-load relationships. Wind energy displaces natural gas and coal in scenarios with relatively expensive natural gas or with GHG fees.more » Correspondingly, annual emissions of NOx, SO2, and CO2 are reduced by 20-40% in these cases. NOx emissions, which are a concern as a precursor of ground-level ozone, are relatively high and consistent across scenarios during summer, when peak electricity loads occur and wind resources in the region are comparatively weak. Accounting for the difference in start-up versus stabilized NOx emissions rates for natural gas plants had little impact on region-wide emissions estimates due to the dominant contribution from coal-fired plants, but would be more important in the vicinity of the natural gas units.« less

  6. Effects of plug-in hybrid electric vehicles on ozone concentrations in Colorado.

    PubMed

    Brinkman, Gregory L; Denholm, Paul; Hannigan, Michael P; Milford, Jana B

    2010-08-15

    This study explores how ozone concentrations in the Denver, CO area might have been different if plug-in hybrid electric vehicles (PHEVs) had replaced light duty gasoline vehicles in summer 2006. A unit commitment and dispatch model was used to estimate the charging patterns of PHEVs and dispatch power plants to meet electricity demand. Emission changes were estimated based on gasoline displacement and the emission characteristics of the power plants providing additional electricity. The Comprehensive Air Quality Model with extensions (CAMx) was used to simulate the effects of these emissions changes on ozone concentrations. Natural gas units provided most of the electricity used for charging PHEVs in the scenarios considered. With 100% PHEV penetration, nitrogen oxide (NO(x)) emissions were reduced by 27 tons per day (tpd) from a fleet of 1.7 million vehicles and were increased by 3 tpd from power plants; VOC emissions were reduced by 57 tpd. These emission changes reduced modeled peak 8-h average ozone concentrations by approximately 2-3 ppb on most days. Ozone concentration increases were modeled for small areas near central Denver. Future research is needed to forecast when significant PHEV penetration may occur and to anticipate characteristics of the corresponding power plant and vehicle fleets.

  7. Coordinated Scheduling for Interdependent Electric Power and Natural Gas Infrastructures

    DOE PAGES

    Zlotnik, Anatoly; Roald, Line; Backhaus, Scott; ...

    2016-03-24

    The extensive installation of gas-fired power plants in many parts of the world has led electric systems to depend heavily on reliable gas supplies. The use of gas-fired generators for peak load and reserve provision causes high intraday variability in withdrawals from high-pressure gas transmission systems. Such variability can lead to gas price fluctuations and supply disruptions that affect electric generator dispatch, electricity prices, and threaten the security of power systems and gas pipelines. These infrastructures function on vastly different spatio-temporal scales, which prevents current practices for separate operations and market clearing from being coordinated. Here in this article, wemore » apply new techniques for control of dynamic gas flows on pipeline networks to examine day-ahead scheduling of electric generator dispatch and gas compressor operation for different levels of integration, spanning from separate forecasting, and simulation to combined optimal control. We formulate multiple coordination scenarios and develop tractable physically accurate computational implementations. These scenarios are compared using an integrated model of test networks for power and gas systems with 24 nodes and 24 pipes, respectively, which are coupled through gas-fired generators. The analysis quantifies the economic efficiency and security benefits of gas-electric coordination and dynamic gas system operation.« less

  8. Feasibility of a computer-assisted feedback system between dispatch centre and ambulances.

    PubMed

    Lindström, Veronica; Karlsten, Rolf; Falk, Ann-Charlotte; Castrèn, Maaret

    2011-06-01

    The aim of the study was to evaluate the feasibility of a newly developed computer-assisted feedback system between dispatch centre and ambulances in Stockholm, Sweden. A computer-assisted feedback system based on a Finnish model was designed to fit the Swedish emergency medical system. Feedback codes were identified and divided into three categories; assessment of patients' primary condition when ambulance arrives at scene, no transport by the ambulance and level of priority. Two ambulances and one emergency medical communication centre (EMCC) in Stockholm participated in the study. A sample of 530 feedback codes sent through the computer-assisted feedback system was reviewed. The information on the ambulance medical records was compared with the feedback codes used and 240 assignments were further analyzed. The used feedback codes sent from ambulance to EMCC were correct in 92% of the assignments. The most commonly used feedback code sent to the emergency medical dispatchers was 'agree with the dispatchers' assessment'. In addition, in 160 assignments there was a mismatch between emergency medical dispatchers and ambulance nurse assessments. Our results have shown a high agreement between medical dispatchers and ambulance nurse assessment. The feasibility of the feedback codes seems to be acceptable based on the small margin of error. The computer-assisted feedback system may, when used on a daily basis, make it possible for the medical dispatchers to receive feedback in a structural way. The EMCC organization can directly evaluate any changes in the assessment protocol by structured feedback sent from the ambulance.

  9. Transient cutaneous vasodilatation and hypotension after drinking in dehydrated and exercising men

    PubMed Central

    Kamijo, Yoshi-Ichiro; Okumoto, Tadashi; Takeno, Yoshiaki; Okazaki, Kazunobu; Inaki, Mitsuharu; Masuki, Shizue; Nose, Hiroshi

    2005-01-01

    We examined whether oropharyngeal stimulation by drinking released the dehydration-induced suppression of cutaneous vasodilatation and decreased mean arterial pressure (MAP) in exercising subjects, and assessed the effects of hypovolaemia or hyperosmolality alone on these responses. Seven young males underwent four hydration conditions. These were two normal plasma volume (PV) trials: normal plasma osmolality (Posmol, control trial) and hyperosmolality (ΔPosmol = +11 mosmol (kg H2O)−1); and two low PV trials: isosmolality (ΔPV = −310 ml) and hyperosmolality (ΔPV = −345 ml; ΔPosmol = +9 mosmol (kg H2O)−1), attained by combined treatment with furosemide (frusemide), hypertonic saline and/or 24 h water restriction. In each trial, the subjects exercised at 60% peak aerobic power for ∼50 min at 30°C atmospheric temperature and 50% relative humidity. When oesophageal temperature (Toes) reached a plateau after ∼30 min of exercise, the subjects drank 200 ml water at 37.5°C within a minute. Before drinking, forearm vascular conductance (FVC), calculated as forearm blood flow divided by MAP, was lowered by 20–40% in hypovolaemia, hyperosmolality, or both, compared with that in the control trial, despite increased Toes. After drinking, FVC increased by ∼20% compared with that before drinking (P < 0.05) in both hyperosmotic trials, but it was greater in normovolaemia than in hypovolaemia (P < 0.05). However, no increases occurred in either isosmotic trial. MAP fell by 4–8 mmHg in both hyperosmotic trials (P < 0.05) after drinking, but more rapidly in normovolaemia than in hypovolaemia. PV and Posmol did not change during this period. Thus, oropharyngeal stimulation by drinking released the dehydration-induced suppression of cutaneous vasodilatation and reduced MAP during exercise, and this was accelerated when PV was restored. PMID:16123108

  10. Dispatcher-assisted compression-only cardiopulmonary resuscitation provides best quality cardiopulmonary resuscitation by laypersons: A randomised controlled single-blinded manikin trial.

    PubMed

    Spelten, Oliver; Warnecke, Tobias; Wetsch, Wolfgang A; Schier, Robert; Böttiger, Bernd W; Hinkelbein, Jochen

    2016-08-01

    High-quality cardiopulmonary resuscitation (CPR) by laypersons is a key determinant of both outcome and survival for out-of-hospital cardiac arrest. Dispatcher-assisted CPR (telephone-CPR, T-CPR) increases the frequency and correctness of bystander-CPR but results in prolonged time to first chest compressions. However, it remains unclear whether instructions for rescue ventilation and/or chest compressions should be recommended for dispatcher-assisted CPR. The aim of this study was to evaluate both principles of T-CPR with respect to CPR quality. Randomised controlled single-blinded manikin trial. University Hospital of Cologne, Germany, 1 July 2012 to 30 September 2012. Sixty laypersons between 18 and 65 years. Medically educated individuals, medical professionals and pregnant women were excluded. Participants were asked to resuscitate a manikin and were randomised into three groups: not dispatcher-assisted (uninstructed) CPR (group 1; U-CPR; n = 20), dispatcher-assisted compression-only CPR (group 2; DACO-CPR; n = 19) and full dispatcher-assisted CPR with rescue ventilation (group 3; DAF-CPR; n = 19). Specific parameters of CPR quality [i.e. no-flow-time (NFT) as well as compression and ventilation parameters] were analysed. To compare different groups we used Student's t test and P less than 0.05 was considered significant. Initial NFT was lowest in the DACO-CPR group (mean 21.3 ± 14.4%), followed by dispatcher-assisted full CPR (mean 49.1 ± 8.5%) and by unassisted CPR (mean 55.0 ± 12.9%). Initial NFT covering the time of instruction was lower in DACO-CPR (12.1 ± 5.4%) as compared to dispatcher-assisted full CPR (20.7 ± 8.1%). Compression depth was similar in all three groups: 40.6 ± 13.0 mm (unassisted CPR), 41.0 ± 12.2 mm (DACO-CPR) and 38.8 ± 15.8 mm (dispatcher-assisted full CPR). Average compression frequency was highest in the DACO-CPR group (65.2 ± 22.4 min) compared with the unassisted CPR group (35.6 ± 24.2 min) and the dispatcher-assisted full CPR group (44.5 ± 10.8 min). Correct rescue ventilation was given in 3.1 ± 11.1% (unassisted CPR) and 1.6 ± 16.1% (dispatcher-assisted full CPR) of all ventilation attempts. Best quality of CPR was achieved by DACO-CPR because of superior compression frequencies and reduced NFT. In contrast, the full dispatcher-assisted CPR with a longer initial instructing phase (initial NFT) did not result in enhanced CPR quality or an optimised compression depth.

  11. An Approximate Dynamic Programming Mode for Optimal MEDEVAC Dispatching

    DTIC Science & Technology

    2015-03-26

    over the myopic policy. This indicates the ADP policy is efficiently managing resources by 28 not immediately sending the nearest available MEDEVAC...DISPATCHING THESIS Presented to the Faculty Department of Operational Sciences Graduate School of Engineering and Management Air Force Institute of Technology...medical evacuation (MEDEVAC) dispatch policies. To solve the MDP, we apply an ap- proximate dynamic programming (ADP) technique. The problem of deciding

  12. Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy.

    PubMed

    Yalçin, Fatih; El-Amrousy, Mahmoud; Müderrisoğlu, Haldun; Korkmaz, Mehmet; Flachskampf, Frank; Tuzcu, Murat; Garcia, Mario G; Thomas, James D

    2002-01-01

    Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (p<0.001). AR peak reverse flow velocity and AR duration decreased from 29 +/- 13 cm/s and 110 =/- 30 msec to 19 +/- 6 cm/s and 80 +/- 29 msec respectively (p<0.001). Transmitral Doppler E wave deceleration time decreased from 327 +/- 85 to 209 +/- 61 s and cardiac output increased from 4.2 +/- 1.0 to 5.2 +/- 1.1 L/minute (p<0.001). The changes in LA pressure were correlated with changes in S/D (r=0.57, p<0.05). The changes in endsystolic LA pressure-volume relationship were also correlated with changes in S/D (r=0.52, p<0.05). Endsystolic LA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

  13. Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy

    NASA Technical Reports Server (NTRS)

    Yalcin, Fatih; El-Amrousy, Mahmoud; Muderrisoglu, Haldun; Korkmaz, Mehmet; Flachskampf, Frank; Tuzcu, Murat; Garcia, Mario G.; Thomas, James D.

    2002-01-01

    Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (p<0.001). AR peak reverse flow velocity and AR duration decreased from 29 +/- 13 cm/s and 110 =/- 30 msec to 19 +/- 6 cm/s and 80 +/- 29 msec respectively (p<0.001). Transmitral Doppler E wave deceleration time decreased from 327 +/- 85 to 209 +/- 61 s and cardiac output increased from 4.2 +/- 1.0 to 5.2 +/- 1.1 L/minute (p<0.001). The changes in LA pressure were correlated with changes in S/D (r=0.57, p<0.05). The changes in endsystolic LA pressure-volume relationship were also correlated with changes in S/D (r=0.52, p<0.05). Endsystolic LA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

  14. The Reliability of Individualized Load-Velocity Profiles.

    PubMed

    Banyard, Harry G; Nosaka, K; Vernon, Alex D; Haff, G Gregory

    2017-11-15

    This study examined the reliability of peak velocity (PV), mean propulsive velocity (MPV), and mean velocity (MV) in the development of load-velocity profiles (LVP) in the full depth free-weight back squat performed with maximal concentric effort. Eighteen resistance-trained men performed a baseline one-repetition maximum (1RM) back squat trial and three subsequent 1RM trials used for reliability analyses, with 48-hours interval between trials. 1RM trials comprised lifts from six relative loads including 20, 40, 60, 80, 90, and 100% 1RM. Individualized LVPs for PV, MPV, or MV were derived from loads that were highly reliable based on the following criteria: intra-class correlation coefficient (ICC) >0.70, coefficient of variation (CV) ≤10%, and Cohen's d effect size (ES) <0.60. PV was highly reliable at all six loads. Importantly, MPV and MV were highly reliable at 20, 40, 60, 80 and 90% but not 100% 1RM (MPV: ICC=0.66, CV=18.0%, ES=0.10, standard error of the estimate [SEM]=0.04m·s -1 ; MV: ICC=0.55, CV=19.4%, ES=0.08, SEM=0.04m·s -1 ). When considering the reliable ranges, almost perfect correlations were observed for LVPs derived from PV 20-100% (r=0.91-0.93), MPV 20-90% (r=0.92-0.94) and MV 20-90% (r=0.94-0.95). Furthermore, the LVPs were not significantly different (p>0.05) between trials, movement velocities, or between linear regression versus second order polynomial fits. PV 20-100% , MPV 20-90% , and MV 20-90% are reliable and can be utilized to develop LVPs using linear regression. Conceptually, LVPs can be used to monitor changes in movement velocity and employed as a method for adjusting sessional training loads according to daily readiness.

  15. Battery Energy Storage Systems to Mitigate the Variability of Photovoltaic Power Generation

    NASA Astrophysics Data System (ADS)

    Gurganus, Heath Alan

    Methods of generating renewable energy such as through solar photovoltaic (PV) cells and wind turbines offer great promise in terms of a reduced carbon footprint and overall impact on the environment. However, these methods also share the attribute of being highly stochastic, meaning they are variable in such a way that is difficult to forecast with sufficient accuracy. While solar power currently constitutes a small amount of generating potential in most regions, the cost of photovoltaics continues to decline and a trend has emerged to build larger PV plants than was once feasible. This has brought the matter of increased variability to the forefront of research in the industry. Energy storage has been proposed as a means of mitigating this increased variability --- and thus reducing the need to utilize traditional spinning reserves --- as well as offering auxiliary grid services such as peak-shifting and frequency control. This thesis addresses the feasibility of using electrochemical storage methods (i.e. batteries) to decrease the ramp rates of PV power plants. By building a simulation of a grid-connected PV array and a typical Battery Energy Storage System (BESS) in the NetLogo simulation environment, I have created a parameterized tool that can be tailored to describe almost any potential PV setup. This thesis describes the design and function of this model, and makes a case for the accuracy of its measurements by comparing its simulated output to that of well-documented real world sites. Finally, a set of recommendations for the design and operational parameters of such a system are then put forth based on the results of several experiments performed using this model.

  16. Introducing systematic dispatcher-assisted cardiopulmonary resuscitation (telephone-CPR) in a non-Advanced Medical Priority Dispatch System (AMPDS): implementation process and costs.

    PubMed

    Dami, Fabrice; Fuchs, Vincent; Praz, Laurent; Vader, John-Paul

    2010-07-01

    In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12 months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.

  17. Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruth, Mark F.; Lunacek, Monte S.; Jones, Birk

    To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to windmore » and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.« less

  18. Space station WP-04 power system preliminary analysis and design document, volume 3

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Rocketdyne plans to generate a system level specification for the Space Station Electric Power System (EPS) in order to facilitate the usage, accountability, and tracking of overall system level requirements. The origins and status of the verification planning effort are traced and an overview of the Space Station program interactions are provided. The work package level interfaces between the EPS and the other Space Station work packages are outlined. A trade study was performed to determine the peaking split between PV and SD, and specifically to compare the inherent total peaking capability with proportionally shared peaking. In order to determine EPS cost drivers for the previous submittal of DRO2, the life cycle cost (LCC) model was run to identify the more significant costs and the factors contributing to them.

  19. Design and operation of grid-interactive thin-film silicon PV systems

    NASA Astrophysics Data System (ADS)

    Marion, Bill; Atmaram, Gobind; Lashway, Clin; Strachan, John W.

    Results are described from the operation of 11 thin-film amorphous silicon photovoltaic systems at three test facilities: the Florida Solar Energy Center, the New Mexico Solar Energy Institute, and Sandia National Laboratories. Commercially available modules from four US manufacturers are used in these systems, with array sizes from 133 to 750 W peak. Measured array efficiencies are from 3.1 to 4.8 percent. Except for one manufacturer, array peak power is in agreement with the calculated design ratings. For certain grid-connected systems, nonoptimal operation exists because the array peak power voltage is below the lower voltage limit of the power conditioning system. Reliability problems are found in two manufacturers' modules when shorts to ground and terminal corrosion occur. Array leakage current data are presented.

  20. Improving emergency medical dispatching with emphasis on mass-casualty incidents.

    PubMed

    Kleinoscheg, Gabriel; Burgsteiner, Harald; Bernroider, Martin; Kiechle, Günter; Obermayer, Maria

    2014-01-01

    Dispatching ambulances is a demanding and stressful task for dispatchers. This is especially true in case of mass-casualty incidents. Therefore, the aim of this work was to investigate if and to what extent the dispatch operation of the Red Cross Salzburg can be optimized on such occasions with a computerized system. The basic problem of a dynamic multi-vehicle Dial-a-Ride Problem with time windows was enhanced according to the requirements of the Red Cross Salzburg. The general objective was to minimize the total mileage covered by ambulances and the waiting time of patients. Furthermore, in case of emergencies suitable adaptions to a plan should be carried out automatically. Consequently, the problem is solved by using the Adaptive Large Neighborhood Search. Evaluation results indicate that the system outperforms a human dispatcher by between 2.5% and 36% within 1 minute of runtime concerning total costs. Moreover, the system's response time in case that a plan has to be updated is less than 1 minute on average.

  1. Data centers as dispatchable loads to harness stranded power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Kibaek; Yang, Fan; Zavala, Victor M.

    Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast,more » optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.« less

  2. Data centers as dispatchable loads to harness stranded power

    DOE PAGES

    Kim, Kibaek; Yang, Fan; Zavala, Victor M.; ...

    2016-07-20

    Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast,more » optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.« less

  3. Hybrid robust predictive optimization method of power system dispatch

    DOEpatents

    Chandra, Ramu Sharat [Niskayuna, NY; Liu, Yan [Ballston Lake, NY; Bose, Sumit [Niskayuna, NY; de Bedout, Juan Manuel [West Glenville, NY

    2011-08-02

    A method of power system dispatch control solves power system dispatch problems by integrating a larger variety of generation, load and storage assets, including without limitation, combined heat and power (CHP) units, renewable generation with forecasting, controllable loads, electric, thermal and water energy storage. The method employs a predictive algorithm to dynamically schedule different assets in order to achieve global optimization and maintain the system normal operation.

  4. Examining the Fundamental Obstructs of Adopting Cloud Computing for 9-1-1 Dispatch Centers in the USA

    ERIC Educational Resources Information Center

    Osman, Abdulaziz

    2016-01-01

    The purpose of this research study was to examine the unknown fears of embracing cloud computing which stretches across measurements like fear of change from leaders and the complexity of the technology in 9-1-1 dispatch centers in USA. The problem that was addressed in the study was that many 9-1-1 dispatch centers in USA are still using old…

  5. Solar hybrid power plants: Solar energy contribution in reaching full dispatchability and firmness

    NASA Astrophysics Data System (ADS)

    Servert, Jorge F.; López, Diego; Cerrajero, Eduardo; Rocha, Alberto R.; Pereira, Daniel; Gonzalez, Lucía

    2016-05-01

    Renewable energies for electricity generation have always been considered as a risk for the electricity system due to its lack of dispatchability and firmness. Renewable energies penetration is constrained to strong grids or else its production must be limited to ensure grid stability, which is kept by the usage of hydropower energy or fossil-fueled power plants. CSP technology has an opportunity to arise not only as a dispatchable and firm technology, but also as an alternative that improves grid stability. To achieve that objective, solar hybrid configurations are being developed, being the most representative three different solutions: SAPG, ISCC and HYSOL. A reference scenario in Kingdom of Saudi Arabia (KSA) has been defined to compare these solutions, which have been modelled, simulated and evaluated in terms of dispatchability and firmness using ratios defined by the authors. The results show that: a) SAPG obtains the highest firmness KPI values, but no operation constraints have been considered for the coal boiler and the solar energy contribution is limited to 1.7%, b) ISCC provides dispatchable and firm electricity production but its solar energy contribution is limited to a 6.4%, and c) HYSOL presents the higher solar energy contribution of all the technologies considered: 66.0% while providing dispatchable and firm generation in similar conditions as SAPG and ISCC.

  6. Optimal Dispatch of Unreliable Electric Grid-Connected Diesel Generator-Battery Power Systems

    NASA Astrophysics Data System (ADS)

    Xu, D.; Kang, L.

    2015-06-01

    Diesel generator (DG)-battery power systems are often adopted by telecom operators, especially in semi-urban and rural areas of developing countries. Unreliable electric grids (UEG), which have frequent and lengthy outages, are peculiar to these regions. DG-UEG-battery power system is an important kind of hybrid power system. System dispatch is one of the key factors to hybrid power system integration. In this paper, the system dispatch of a DG-UEG-lead acid battery power system is studied with the UEG of relatively ample electricity in Central African Republic (CAR) and UEG of poor electricity in Congo Republic (CR). The mathematical models of the power system and the UEG are studied for completing the system operation simulation program. The net present cost (NPC) of the power system is the main evaluation index. The state of charge (SOC) set points and battery bank charging current are the optimization variables. For the UEG in CAR, the optimal dispatch solution is SOC start and stop points 0.4 and 0.5 that belong to the Micro-Cycling strategy and charging current 0.1 C. For the UEG in CR, the optimal dispatch solution is of 0.1 and 0.8 that belongs to the Cycle-Charging strategy and 0.1 C. Charging current 0.1 C is suitable for both grid scenarios compared to 0.2 C. It makes the dispatch strategy design easier in commercial practices that there are a few very good candidate dispatch solutions with system NPC values close to that of the optimal solution for both UEG scenarios in CAR and CR.

  7. The appropriateness of emergency medical service responses in the eThekwini district of KwaZulu-Natal, South Africa.

    PubMed

    Newton, P R; Naidoo, R; Brysiewicz, P

    2015-09-19

     Emergency medical services (EMS) are sometimes required to respond to cases that are later found not to be emergencies, resulting in high levels of inappropriate responses. This study evaluated the extent to which this occurs.  All cases dispatched over 72 hours by the eThekwini EMS in Durban, South Africa, were prospectively enrolled in a quantitative descriptive study. Vehicle control forms containing dispatch data were matched and compared with patient report forms containing epidemiological and clinical data to describe the nature and extent of inappropriate responses based on patient need. Data were subjected to simple descriptive analysis, correlations and χ2 testing.  A total of 1 385 cases met the study inclusion criteria. Marked variations existed between dispatch and on-scene priority settings, most notably in the highest priority 'red-code' category, which constituted >56% of cases dispatched yet accounted for <2% at the scene (p<0.001). Conversely, >80% of 'red-code' dispatches required a lower priority response. When comparing resource allocation according to patient interventional needs, >58% of cases required either no intervention or transport only and almost 36% required basic life support intervention only (p<0.001). Moreover, <12% of advanced life support dispatches were for patients found to be 'red code' at the scene.  There is a significant mismatch between the dispatch of EMS resources and actual patient need in the eThekwini district, with significantly high levels of inappropriate emergency responses.

  8. Paediatric medical emergency calls to a Danish Emergency Medical Dispatch Centre: a retrospective, observational study.

    PubMed

    Andersen, Kasper; Mikkelsen, Søren; Jørgensen, Gitte; Zwisler, Stine Thorhauge

    2018-01-05

    Little is known regarding paediatric medical emergency calls to Danish Emergency Medical Dispatch Centres (EMDC). This study aimed to investigate these calls, specifically the medical issues leading to them and the pre-hospital units dispatched to the paediatric emergencies. We performed a retrospective, observational study on paediatric medical emergency calls managed by the EMDC in the Region of Southern Denmark in February 2016. We reviewed audio recordings of emergency calls and ambulance records to identify calls concerning patients ≤ 15 years. We examined EMDC dispatch records to establish how the medical issues leading to these calls were classified and which pre-hospital units were dispatched to the paediatric emergencies. We analysed the data using descriptive statistics. Of a total of 7052 emergency calls in February 2016, 485 (6.9%) concerned patients ≤ 15 years. We excluded 19 and analysed the remaining 466. The reported medical issues were commonly classified as: "seizures" (22.1%), "sick child" (18.9%) and "unclear problem" (12.9%). The overall most common pre-hospital response was immediate dispatch of an ambulance with sirens and lights with a supporting physician-manned mobile emergency care unit (56.4%). The classification of medical issues and the dispatched pre-hospital units varied with patient age. We believe our results might help focus the paediatric training received by emergency medical dispatch staff on commonly encountered medical issues, such as the symptoms and conditions pertaining to the symptom categories "seizures" and "sick child". Furthermore, the results could prove useful in hypothesis generation for future studies examining paediatric medical emergency calls. Almost 7% of all calls concerned patients ≤ 15 years. Medical issues pertaining to the symptom categories "seizures", "sick child" and "unclear problem" were common and the calls commonly resulted in urgent pre-hospital responses.

  9. Stress and salivary cortisol in emergency medical dispatchers: A randomized shifts control trial

    PubMed Central

    Bedini, Sarah; Braun, François; Weibel, Laurence; Aussedat, Michel; Pereira, Bruno; Dutheil, Frédéric

    2017-01-01

    Stress at work is a public health concern. Phone operators in emergency medical dispatch centers are particularly at risk. We aimed to demonstrate that the most stressful time for emergency medical dispatchers is the shift when they receive emergency incoming calls, with cortisol as a biomarker of stress. For each emergency medical dispatcher, we measured outcomes over a control day and during three types of shift: Incoming emergency call, Dispatch and Re-assessment. The pattern of shifts was randomized. Saliva was sampled every 15 minutes for 2 hours, i.e. 6 consecutive times, starting 15 minutes after the first life-and-death incoming emergency call between 2 and 5 pm during three types of shift. We measured saliva cortisol every 2 hours over a control day, from 7am to 9pm. Perceived stress was assessed by a visual analog scale. We recruited 22 phone operators aged 36.4+/-10.8 years old (14 women and 8 men). Cortisol values were higher during the Incoming emergency call shift than during the Dispatch (p = .04) and Re-assessment (p = .04) shifts. The increase in cortisol levels was greater in men than in women (p = .009). There were no differences between control values and those of the three shifts. The kinetics of cortisol increased with greater perceived stress overall (p < .001) and for each type of shift (Incoming emergency call, p = .02; Dispatch p = .03; Re-assessment: p < .001). The kinetics of cortisol in response to incoming emergency calls was greater when the call was an absolute emergency (p = .03), and also tended to further increase when a subsequent absolute incoming emergency call was received (p = 0.07). In conclusion, the incoming emergency call shift carries particular risk for dispatchers, who have greater perceived stress and a greater increase in cortisol levels. PMID:28505199

  10. Stress and salivary cortisol in emergency medical dispatchers: A randomized shifts control trial.

    PubMed

    Bedini, Sarah; Braun, François; Weibel, Laurence; Aussedat, Michel; Pereira, Bruno; Dutheil, Frédéric

    2017-01-01

    Stress at work is a public health concern. Phone operators in emergency medical dispatch centers are particularly at risk. We aimed to demonstrate that the most stressful time for emergency medical dispatchers is the shift when they receive emergency incoming calls, with cortisol as a biomarker of stress. For each emergency medical dispatcher, we measured outcomes over a control day and during three types of shift: Incoming emergency call, Dispatch and Re-assessment. The pattern of shifts was randomized. Saliva was sampled every 15 minutes for 2 hours, i.e. 6 consecutive times, starting 15 minutes after the first life-and-death incoming emergency call between 2 and 5 pm during three types of shift. We measured saliva cortisol every 2 hours over a control day, from 7am to 9pm. Perceived stress was assessed by a visual analog scale. We recruited 22 phone operators aged 36.4+/-10.8 years old (14 women and 8 men). Cortisol values were higher during the Incoming emergency call shift than during the Dispatch (p = .04) and Re-assessment (p = .04) shifts. The increase in cortisol levels was greater in men than in women (p = .009). There were no differences between control values and those of the three shifts. The kinetics of cortisol increased with greater perceived stress overall (p < .001) and for each type of shift (Incoming emergency call, p = .02; Dispatch p = .03; Re-assessment: p < .001). The kinetics of cortisol in response to incoming emergency calls was greater when the call was an absolute emergency (p = .03), and also tended to further increase when a subsequent absolute incoming emergency call was received (p = 0.07). In conclusion, the incoming emergency call shift carries particular risk for dispatchers, who have greater perceived stress and a greater increase in cortisol levels.

  11. Reliability assessment of ballistic jump squats and bench throws.

    PubMed

    Alemany, Joseph A; Pandorf, Clay E; Montain, Scott J; Castellani, John W; Tuckow, Alexander P; Nindl, Bradley C

    2005-02-01

    The purpose of this investigation was to determine the test-retest reliability and coefficient of variation of 2 novel physical performance tests. Ten healthy men (22.0 +/- 3.0 years, 87.0 +/- 8.0 kg, 20.0 +/- 5.0% body fat) performed 30 continuous and dynamic jump squats (JS) and bench throws (BT) on 4 separate occasions. The movements were performed under loaded conditions utilizing 30% of subject's predetermined 1 repetition maximum in the back squat and bench press. Mean power (MP; W), peak power (PP; W), mean velocity (MV; m.s(-1)), peak velocity (PV; m.s(-1)), and total work (TW; J) were assessed using a ballistic measurement system (Innervations Inc., Muncie, IN). Data were analyzed using repeated measures analysis of variance with Duncan's post hoc test when mean differences were p < or = 0.05. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (CV%) were also calculated. All values are presented as mean +/- SE. BT variables were statistically similar across the 4 sessions: MP (350.0 +/- 13.9 W), PP (431.4 +/- 18.5 W) MV (1.6 +/- 0.03 m.s(-1)), PV (2.0 +/- 0.03 m.s(-1)), and TW (199.1 +/- 7.2 J). For JS, session 3 PP (1,669.8 +/- 111.2 W) was significantly greater vs. sessions 1, 2, and 4 (1,601.2 +/- 58.4 W). Session 4 MP (1,403.2 +/- 88.6 W) and MV (1.9 +/- 0.1 m.s(-1)) for JS were significantly lower during sessions 1, 2, and 3 (MP: 1,479.4.5 +/- 44.8 W, MV: 2.0 +/- 0.05 m.s(-1)). TW (834.7 +/- 24.3 J) and PV (2.2 +/- 0.04 m.s(-1)) were statistically similar during all sessions for JS. The CVs ranged from 3.0 to 7.6% for the BT and 3.2 to 5.7% for the JS. ICCs for MP, PP, MV, PV, and TW were 0.92, 0.95, 0.94, 0.91, and 0.95, respectively, during BT. ICCs during JS for MP, PP, MV, PV, and TW were 0.96, 0.98, 0.94, 0.94, and 0.89, respectively. The results of the current study support the use of a 30 continuous and dynamic BT protocol as a reliable upper-body physical performance test, which can be administered with minimal practice. Slightly greater variability for JS was observed, although the test had high reliability.

  12. Use of Dobutamine Stress Echocardiography for Periprocedural Evaluation of a Case of Critical Valvular Pulmonary Stenosis with Delayed Presentation.

    PubMed

    Barik, Ramachandra; Akula, Siva Prasad; Damera, Sheshagiri Rao

    2016-01-01

    We report a case illustrating a 39-year-old man with delayed presentation of severe pulmonary valve (PV) stenosis, clinical evidence of congestive right heart failure in the form of enlarged liver, raised jugular venous pressure, and anasarca without cyanosis. Echocardiography (echo) was used both for diagnosis and monitoring this patient as main tool. The contractile reserve of the right ventricle (RV) was evaluated by infusion of dobutamine and diuretic for 4 days before pulmonary balloon valvotomy. Both the tricuspid annular peak systolic excursion and diastolic (diastolic anterograde flow through PV) function of RV improved after percutaneous balloon pulmonary valvotomy. These improvements were clinically apparent by complete resolution of anasarca, pericardial effusion, and normalization albumin-globulin ratio. The periprocedural echo findings were quite unique in this illustration.

  13. Use of Dobutamine Stress Echocardiography for Periprocedural Evaluation of a Case of Critical Valvular Pulmonary Stenosis with Delayed Presentation

    PubMed Central

    Barik, Ramachandra; Akula, Siva Prasad; Damera, Sheshagiri Rao

    2016-01-01

    We report a case illustrating a 39-year-old man with delayed presentation of severe pulmonary valve (PV) stenosis, clinical evidence of congestive right heart failure in the form of enlarged liver, raised jugular venous pressure, and anasarca without cyanosis. Echocardiography (echo) was used both for diagnosis and monitoring this patient as main tool. The contractile reserve of the right ventricle (RV) was evaluated by infusion of dobutamine and diuretic for 4 days before pulmonary balloon valvotomy. Both the tricuspid annular peak systolic excursion and diastolic (diastolic anterograde flow through PV) function of RV improved after percutaneous balloon pulmonary valvotomy. These improvements were clinically apparent by complete resolution of anasarca, pericardial effusion, and normalization albumin-globulin ratio. The periprocedural echo findings were quite unique in this illustration. PMID:28465962

  14. Comparing post-combustion CO2 capture operation at retrofitted coal-fired power plants in the Texas and Great Britain electric grids

    NASA Astrophysics Data System (ADS)

    Cohen, Stuart M.; Chalmers, Hannah L.; Webber, Michael E.; King, Carey W.

    2011-04-01

    This work analyses the carbon dioxide (CO2) capture system operation within the Electric Reliability Council of Texas (ERCOT) and Great Britain (GB) electric grids using a previously developed first-order hourly electricity dispatch and pricing model. The grids are compared in their 2006 configuration with the addition of coal-based CO2 capture retrofits and emissions penalties from 0 to 100 US dollars per metric ton of CO2 (USD/tCO2). CO2 capture flexibility is investigated by comparing inflexible CO2 capture systems to flexible ones that can choose between full- and zero-load CO2 capture depending on which operating mode has lower costs or higher profits. Comparing these two grids is interesting because they have similar installed capacity and peak demand, and both are isolated electricity systems with competitive wholesale electricity markets. However, differences in capacity mix, demand patterns, and fuel markets produce diverging behaviours of CO2 capture at coal-fired power plants. Coal-fired facilities are primarily base load in ERCOT for a large range of CO2 prices but are comparably later in the dispatch order in GB and consequently often supply intermediate load. As a result, the ability to capture CO2 is more important for ensuring dispatch of coal-fired facilities in GB than in ERCOT when CO2 prices are high. In GB, higher overall coal prices mean that CO2 prices must be slightly higher than in ERCOT before the emissions savings of CO2 capture offset capture energy costs. However, once CO2 capture is economical, operating CO2 capture on half the coal fleet in each grid achieves greater emissions reductions in GB because the total coal-based capacity is 6 GW greater than in ERCOT. The market characteristics studied suggest greater opportunity for flexible CO2 capture to improve operating profits in ERCOT, but profit improvements can be offset by a flexibility cost penalty.

  15. Real-Time, Wide Area Dispatch of Mobil Tank Trucks

    DTIC Science & Technology

    1987-01-01

    human dispatchers it assists. Using CAD, Mobil has substantially re- duced costs and staff while improving customer service. I n the spring of 1985, a...process by establishing the Mobil order response center (MORC). To use MORC, the customer dials a toll-free number, available 24 hours a day, seven...MATS Figwe 3: Mobil light products order and dispatch information flow. Customers call an audio re- sponse computer system named MORC ( Mobil order

  16. Clean Energy Generation and Dispatch in Reformed Wholesale Electricity Markets: Experience in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Shengru; Hurlbut, David J; Li, Ma

    In recent years, the US electricity market has undergone several stages of reform, and gradually formed the market where the wholesale electricity price is determined by the supply and demand. The US electricity market also changes along with the rapid development of clean energy, forming a number of the market mechanisms that is specifically developed for clean energy power generation characteristics. On the basis of discussing the pricing mechanism of US electricity market, this paper analyzes the experience and practice of encouraging renewable energy development policy and clean energy dispatch from the angle of market mechanism and dispatching decision, andmore » puts forward the reference for clean energy dispatching in China.« less

  17. Mapping potential vorticity dynamics on saturn: Zonal mean circulation from Cassini and Voyager data

    NASA Astrophysics Data System (ADS)

    Read, P. L.; Conrath, B. J.; Fletcher, L. N.; Gierasch, P. J.; Simon-Miller, A. A.; Zuchowski, L. C.

    2009-12-01

    Maps of Ertel potential vorticity on isentropic surfaces (IPV) and quasi-geostrophic potential vorticity (QGPV) are well established in dynamical meteorology as powerful sources of insight into dynamical processes involving 'balanced' flow (i.e. geostrophic or similar). Here we derive maps of zonal mean IPV and QGPV in Saturn's upper troposphere and lower stratosphere by making use of a combination of velocity measurements, derived from the combined tracking of cloud features in images from the Voyager and Cassini missions, and thermal measurements from the Cassini Composite Infrared Spectrometer (CIRS) instrument. IPV and QGPV are mapped and compared for the entire globe between latitudes 89∘S-82∘N. As on Jupiter, profiles of zonally averaged PV show evidence for a step-like "stair-case" pattern suggestive of local PV homogenisation, separated by strong PV gradients in association with eastward jets. The northward gradient of PV (IPV or QGPV) is found to change sign in several places in each hemisphere, however, even when baroclinic contributions are taken into account. The stability criterion with respect to Arnol'd's second stability theorem may be violated near the peaks of westward jets. Visible, near-IR and thermal-IR Cassini observations have shown that these regions exhibit many prominent, large-scale eddies and waves, e.g. including 'storm alley'. This suggests the possibility that at least some of these features originate from instabilities of the background zonal flow.

  18. Energy conservation, energy efficiency and energy savings regulatory hypotheses - taxation, subsidies and underlying economics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trumpy, T.

    1995-12-01

    More efficient use of energy resources can be promoted by various regulatory means, i.e., taxation, subsidies, and pricing. Various incentives can be provided by income and revenue tax breaks-deductible energy audit fees, energy saving investment credits, breaks for energy saving entrepreneurs, and energy savings accounts run through utility accounts. Value added and excise taxes can also be adjusted to reward energy saving investments and energy saving entrepreneurial activity. Incentives can be provided in the form of cash refunds, including trade-in-and-scrap programs and reimbursements or subsidies on audit costs and liability insurance. Pricing incentives include lower rates for less energy use,more » prepayment of deposit related to peak load use, electronically dispatched multiple tariffs, savings credits based on prior peak use, and subsidized {open_quotes}leasing{close_quotes} of more efficient appliances and lights. Credits, with an emphasis on pooling small loans, and 5-year energy savings contracts are also discussed.« less

  19. Pre-recorded instructional audio vs. dispatchers' conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study.

    PubMed

    Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey

    2018-01-01

    To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio ( n =57); or (2) verbal dispatcher assistance ( n =52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P >0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P <0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min -1 ) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.

  20. Predictive Ability of an Emergency Medical Dispatch Stroke Diagnostic Tool in Identifying Hospital-Confirmed Strokes.

    PubMed

    Clawson, Jeff J; Scott, Greg; Gardett, Isabel; Youngquist, Scott; Taillac, Peter; Fivaz, Conrad; Olola, Christopher

    2016-08-01

    Early hospital notification of a possible stroke arriving via emergency medical services (EMS) can prepare stroke center personnel for timely treatment, especially timely administration of tissue plasminogen activator. Stroke center notification from the emergency dispatch center-before responders reach the scene-may promote even earlier and faster system activation, meaning that stroke center teams may be ready to receive patients as soon as the ambulance arrives. This study evaluates the use of a Medical Priority Dispatch System (MPDS; Priority Dispatch Corp., Salt Lake City, UT) Stroke Diagnostic Tool (SDxT) to identify possible strokes early by comparing the tools' results to on-scene and hospital findings. The retrospective descriptive study utilized stroke data from 3 sources: emergency medical dispatch, EMS, and emergency department/hospital. A total of 830 cases were collected between June 2012 and December 2013, of which 603 (72.7%) had matching dispatch records. Of the 603 cases, 304 (50.4%) were handled using MPDS Stroke Protocol 28. The SDxT had an 86.4% ability (OR [95% CI]: 2.3 [1.5, 3.5]) to effectively identify strokes among all the hospital-confirmed stroke cases (sensitivity), and a 26.6% ability to effectively identify nonstrokes among all the hospital-confirmed nonstroke cases (specificity). The SDxT demonstrated a very high sensitivity, compared to similar tools used in the field and at dispatch. The specificity was somewhat low, but this was expected-and is intended in the creation of protocols to be used over the phone in emergency situations. The tool is a valuable method for identifying strokes early and may allow early hospital notification. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. A novel protocol for dispatcher assisted CPR improves CPR quality and motivation among rescuers-A randomized controlled simulation study.

    PubMed

    Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo

    2017-01-01

    Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. View west within the periphery of the load dispatch model ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west within the periphery of the load dispatch model board, operator's console is at lower center and button board is at lower right of the photograph; section of model board shown covers substation from Perryman (left) to Frankford (right); instruments at right center of photograph formerly monitored energy usage and were replaced by computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  3. Evaluating the CO 2 emissions reduction potential and cost of power sector re-dispatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinberg, Daniel C.; Bielen, David A.; Townsend, Aaron

    Prior studies of the U.S. electricity sector have recognized the potential to reduce carbon dioxide (CO2) emissions by substituting generation from coal-fired units with generation from under-utilized and lower-emitting natural gas-fired units; in fact, this type of 're-dispatch' was invoked as one of the three building blocks used to set the emissions targets under the Environmental Protection Agency's Clean Power Plan. Despite the existence of surplus natural gas capacity in the U.S., power system operational constraints not often considered in power sector policy analyses, such as transmission congestion, generator ramping constraints, minimum generation constraints, planned and unplanned generator outages, andmore » ancillary service requirements, could limit the potential and increase the cost of coal-to-gas re-dispatch. Using a highly detailed power system unit commitment and dispatch model, we estimate the maximum potential for re-dispatch in the Eastern Interconnection, which accounts for the majority of coal capacity and generation in the U.S. Under our reference assumptions, we find that maximizing coal-to-gas re-dispatch yields emissions reductions of 230 million metric tons (Mt), or 13% of power sector emissions in the Eastern Interconnection, with a corresponding average abatement cost of $15-$44 per metric ton of CO2, depending on the assumed supply elasticity of natural gas.« less

  4. Maintenance of Velocity and Power With Cluster Sets During High-Volume Back Squats.

    PubMed

    Tufano, James J; Conlon, Jenny A; Nimphius, Sophia; Brown, Lee E; Seitz, Laurent B; Williamson, Bryce D; Haff, G Gregory

    2016-10-01

    To compare the effects of a traditional set structure and 2 cluster set structures on force, velocity, and power during back squats in strength-trained men. Twelve men (25.8 ± 5.1 y, 1.74 ± 0.07 m, 79.3 ± 8.2 kg) performed 3 sets of 12 repetitions at 60% of 1-repetition maximum using 3 different set structures: traditional sets (TS), cluster sets of 4 (CS4), and cluster sets of 2 (CS2). When averaged across all repetitions, peak velocity (PV), mean velocity (MV), peak power (PP), and mean power (MP) were greater in CS2 and CS4 than in TS (P < .01), with CS2 also resulting in greater values than CS4 (P < .02). When examining individual sets within each set structure, PV, MV, PP, and MP decreased during the course of TS (effect sizes 0.28-0.99), whereas no decreases were noted during CS2 (effect sizes 0.00-0.13) or CS4 (effect sizes 0.00-0.29). These results demonstrate that CS structures maintain velocity and power, whereas TS structures do not. Furthermore, increasing the frequency of intraset rest intervals in CS structures maximizes this effect and should be used if maximal velocity is to be maintained during training.

  5. Interior view of Dispatch Office and counter, facing south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view of Dispatch Office and counter, facing south - International Longshoremen's & Warehousemen's Union Hall, Naval Civil Engineering Laboratory, Port Hueneme Road, Port Hueneme, Ventura County, CA

  6. 76 FR 29335 - Qualification, Service, and Use of Crewmembers and Aircraft Dispatchers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-20

    ...On January 12, 2009, the FAA published a notice of proposed rulemaking on qualification, service, and use of crewmembers and aircraft dispatchers. Because of the complexity of the issues and the concerns raised by commenters, the FAA is issuing this supplemental notice of proposed rulemaking. The FAA proposes to amend the regulations for crewmember and aircraft dispatcher training programs in domestic, flag, and supplemental operations. The proposed regulations enhance traditional training programs by requiring the use of flight simulation training devices for flightcrew members and including additional training and evaluation requirements for all crewmembers and aircraft dispatchers in areas that are critical to safety. The proposal also reorganizes and revises the qualification, training, and evaluation requirements. The proposed changes are intended to contribute significantly to reducing aviation accidents.

  7. Automatic low-order aberration compensator for solid-state slab lasers

    NASA Astrophysics Data System (ADS)

    Yu, Xin; Dong, Lizhi; Lai, Boheng; Yang, Ping; Kong, Qingfeng; Yang, Kangjian; Liu, Yong; Tang, Guomao; Xu, Bing

    2016-09-01

    Slab geometry is a promising architecture for power scaling of solid-state lasers. By propagating the laser beams along zigzag path in the gain medium, the thermal effects can be well compensated. However, in the non-zigzag direction, the thermal effects are not compensated. Among the overall aberrations in the slab lasers, the major contributors are two low-order aberrations: astigmatism and defocus, which can range up to over 100 microns (peak to valley), leading to detracted beam quality. Another problem with slab lasers is that the output beams are generally in a rectangular aperture with high aspect ratio (normally 1:10), where square beams are favorable for many applications. In order to solve these problems, we propose an automatic low-order aberration compensation system. This system is composed of three lenses fixed on a motorized rail, one is a spherical lens and the others are cylindrical lenses. Astigmatism and defocus can be compensated by merely adjusting the distances between the lenses. Two wave-front sensors are employed in this compensation system, one is used for detecting the initial parameters of the beams, and the other one is used for detecting the remaining aberrations after correction. The adjustments of the three lenses are directly calculated based on beam parameters using ray tracing method. The initial size of the beam is 3.2mm by 26mm, and peak to valley(PV) value of the wave-front is 33.07λ(λ=1064nm). After correction, the dimension becomes 40mm by 40mm, and peak to valley (PV) value of the wave-front is less than 2 microns.

  8. Development of a Battery-Free Solar Refrigerator

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K.; Bergeron, David J., III

    2000-01-01

    Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

  9. Evaluation of a binary optimization approach to find the optimum locations of energy storage devices in a power grid with stochastically varying loads and wind generation

    NASA Astrophysics Data System (ADS)

    Dar, Zamiyad

    The prices in the electricity market change every five minutes. The prices in peak demand hours can be four or five times more than the prices in normal off peak hours. Renewable energy such as wind power has zero marginal cost and a large percentage of wind energy in a power grid can reduce the price significantly. The variability of wind power prevents it from being constantly available in peak hours. The price differentials between off-peak and on-peak hours due to wind power variations provide an opportunity for a storage device owner to buy energy at a low price and sell it in high price hours. In a large and complex power grid, there are many locations for installation of a storage device. Storage device owners prefer to install their device at locations that allow them to maximize profit. Market participants do not possess much information about the system operator's dispatch, power grid, competing generators and transmission system. The publicly available data from the system operator usually consists of Locational Marginal Prices (LMP), load, reserve prices and regulation prices. In this thesis, we develop a method to find the optimum location of a storage device without using the grid, transmission or generator data. We formulate and solve an optimization problem to find the most profitable location for a storage device using only the publicly available market pricing data such as LMPs, and reserve prices. We consider constraints arising due to storage device operation limitations in our objective function. We use binary optimization and branch and bound method to optimize the operation of a storage device at a given location to earn maximum profit. We use two different versions of our method and optimize the profitability of a storage unit at each location in a 36 bus model of north eastern United States and south eastern Canada for four representative days representing four seasons in a year. Finally, we compare our results from the two versions of our method with a multi period stochastically optimized economic dispatch of the same power system with storage device at locations proposed by our method. We observe a small gap in profit values arising due to the effect of storage device on market prices. However, we observe that the ranking of different locations in terms of profitability remains almost unchanged. This leads us to conclude that our method can successfully predict the optimum locations for installation of storage units in a complex grid using only the publicly available electricity market data.

  10. Interior detail of dispatch boards in main hall, facing west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior detail of dispatch boards in main hall, facing west - International Longshoremen's & Warehousemen's Union Hall, Naval Civil Engineering Laboratory, Port Hueneme Road, Port Hueneme, Ventura County, CA

  11. Refined genetic algorithm -- Economic dispatch example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheble, G.B.; Brittig, K.

    1995-02-01

    A genetic-based algorithm is used to solve an economic dispatch (ED) problem. The algorithm utilizes payoff information of perspective solutions to evaluate optimality. Thus, the constraints of classical LaGrangian techniques on unit curves are eliminated. Using an economic dispatch problem as a basis for comparison, several different techniques which enhance program efficiency and accuracy, such as mutation prediction, elitism, interval approximation and penalty factors, are explored. Two unique genetic algorithms are also compared. The results are verified for a sample problem using a classical technique.

  12. Flair-fleet location and information reporting

    NASA Technical Reports Server (NTRS)

    Norman, E. R.; Dunlap, M. E.

    1974-01-01

    The FLAIR system, as now produced, automatically updates each vehicle's location and corresponding officer's status once each two seconds and presents this information to police dispatchers in the command and control center. The position of all vehicles available for assignment is displayed on a color video map at each dispatcher's console to an accuracy of 50 feet. This gives the dispatcher a continuous picture of the deployment of the total available force and thus complete command and control of all police under his responsibility.

  13. Sample EP Flow Analysis of Severely Damaged Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werley, Kenneth Alan; McCown, Andrew William

    These are slides for a presentation at the working group meeting of the WESC SREMP Software Product Integration Team on sample EP flow analysis of severely damaged networks. The following topics are covered: ERCOT EP Transmission Model; Zoomed in to Houston and Overlaying StreetAtlas; EMPACT Solve/Dispatch/Shedding Options; QACS BaseCase Power Flow Solution; 3 Substation Contingency; Gen. & Load/100 Optimal Dispatch; Dispatch Results; Shed Load for Low V; Network Damage Summary; Estimated Service Areas (Potential); Estimated Outage Areas (potential).

  14. The Analysis and Discussion in the Effective Application of the Dispatcher Training Based on Case Teaching Method with the Cause from the Action of the Gap Protection of Main Transformer

    NASA Astrophysics Data System (ADS)

    Yuanyuan, Xu; Zhengmao, Zhang; Xiang, Fang; Yuanshuai, Xu; Xinxin, Song

    2018-03-01

    The combination of theory and practice is a difficult problem on dispatcher training. Through a typical example of case, this paper provides an effective case teaching method for dispatcher training, and combines the theoretical discussion of the rule of experience with cases and achieves vividness. It helps students to understand and catch the key points of the theory, and improve their practical skills.

  15. Review for the Korean Health Professionals and International Cooperation Doctors Dispatched to Peru by the Korea International Cooperation Agency (KOICA).

    PubMed

    Kim, Bongyoung

    2015-04-01

    South Korea dispatches Korean nationals to partner developing countries as an Official Development Assistance (ODA) project through the Korea International Cooperation Agency (KOICA). In the health sector, KOICA dispatches international cooperation doctors (ICDs), nurses, physical therapists, radiologic technologists, nutritionists, medical laboratory technologists, occupational therapists, and dental hygienists. A total of 216 ICDs were dispatched over 19 times from 1995 until 2013. There were 19 areas of specialties among the ICDs. The most common specialty was internal medicine (61/216, 28.2%), the second most common specialty was general surgery (43/216, 19.9%), followed by oriental medicine (27/216, 12.5%), pediatrics (17/216, 7.9%), orthopedics (16/216, 7.4%), family medicine (16/216, 7.4%), and odontology (14/216, 6.5%). The ICDs have worked in 21 countries. KOICA dispatched the highest number of ICDs to Asia (97/216, 44.9%), followed by Africa (50/216, 23.1%), Latin America (34/216, 15.7%), the commonwealth of independent states (31/216, 14.4%), and Oceania (4/216, 1.9%). Nobody was dispatched to the Middle East. A total of 134 KOICA health professionals were dispatched to Peru from 1996 until October 1, 2014. Of these, 19.4% (26/134) were ICDs, 44.8% (60/216) were nurses, 20.1% (27/134) were physical therapists, 6.7% (9/134) were radiologic technologists, 2.2% (3/134) were nutritionists, and 6.7% (9/134) were medical laboratory. ICDs' specialties comprised internal medicine (13/26, 50%), family medicine (8/26, 30.8%), pediatrics (2/26, 7.7%), otorhinolaryngology (1/26, 3.8%), orthopedics (1/26, 3.8%), and oriental medicine (1/26, 3.8%). Most of the dispatched health professionals worked at institutions that were supported by KOICA. For this reason, the proportion of health professionals who worked at public health centers (PHCs) was the highest (58.2%, 78/134) when classified by workplace type. Other KOICA health professionals worked at hospitals, governmental organizations (GOs), or schools.

  16. Operational performance of the photovoltaic-powered grain mill and water pump at Tangaye, Upper Volta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martz, J.E.; Ratajczak, A.F.; Delombard, R.

    1982-02-01

    The first two years of operation of a stand alone photovoltaic (PV) power system for the village of Tangaye, Upper Volta in West Africa are described. The purpose of the experiment was to demonstrate that PV systems could provide reliable electrical power for multiple use applications in remote areas where local technical expertise is limited. The 1.8 kW (peak) power system supplies 120-V (d.c.) electrical power to operate a grain mill, a water pump, and mill building lights for the village. The system was initially sized to pump a part of the village water requirements from an existing improved well,more » and to meet a portion of the village grain grinding requirements. The data, observations, experiences, and conclusions developed during the first two years of operation are discussed. Reports of tests of the mills used in the project are included.« less

  17. Flat-plate solar array project. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    Callaghan, W.; Mcdonald, R.

    1986-01-01

    In 1975, the U.S. Government contracted the Jet Propulsion Lab. to develop, by 1985, in conjunction with industry, the photovoltaics (PV) module and array technology required for widespread use of photovoltaics as a significant terrestrial energy source. As a result, a project that eventually became known as the Flat Plate Solar Array (FSA) Project was formed to manage an industry, university, and Government team to perform the necessary research and development. The original goals were to achieve widespread commercial use of PV modules and arrays through the development of technology that would allow them to be profitably sold for $1.07/peak watts (1985 dollars). A 10% module conversion efficiency and a 20 year lifetime were also goals. It is intended that the executive summary provide the means by which one can gain a perspective on 11 years of terrestrial photovoltaic research and development conducted by the FSA Project.

  18. Comparison and Analysis on Mechanical Property and Machinability about Polyetheretherketone and Carbon-Fibers Reinforced Polyetheretherketone

    PubMed Central

    Ji, Shijun; Sun, Changrui; Zhao, Ji; Liang, Fusheng

    2015-01-01

    The aim of this paper is to compare the mechanical property and machinability of Polyetheretherketone (PEEK) and 30 wt% carbon-fibers reinforced Polyetheretherketone (PEEK CF 30). The method of nano-indentation is used to investigate the microscopic mechanical property. The evolution of load with displacement, Young’s modulus curves and hardness curves are analyzed. The results illustrate that the load-displacement curves of PEEK present better uniformity, and the variation of Young’s modulus and hardness of PEEK both change smaller at the experimental depth. The machinability between PEEK and PEEK CF 30 are also compared by the method of single-point diamond turning (SPDT), and the peak-to-valley value (PV) and surface roughness (Ra) are obtained to evaluate machinability of the materials after machining. The machining results show that PEEK has smaller PV and Ra, which means PEEK has superior machinability. PMID:28793428

  19. Comparison and Analysis on Mechanical Property and Machinability about Polyetheretherketone and Carbon-Fibers Reinforced Polyetheretherketone.

    PubMed

    Ji, Shijun; Sun, Changrui; Zhao, Ji; Liang, Fusheng

    2015-07-07

    The aim of this paper is to compare the mechanical property and machinability of Polyetheretherketone (PEEK) and 30 wt% carbon-fibers reinforced Polyetheretherketone (PEEK CF 30). The method of nano-indentation is used to investigate the microscopic mechanical property. The evolution of load with displacement, Young's modulus curves and hardness curves are analyzed. The results illustrate that the load-displacement curves of PEEK present better uniformity, and the variation of Young's modulus and hardness of PEEK both change smaller at the experimental depth. The machinability between PEEK and PEEK CF 30 are also compared by the method of single-point diamond turning (SPDT), and the peak-to-valley value (PV) and surface roughness (Ra) are obtained to evaluate machinability of the materials after machining. The machining results show that PEEK has smaller PV and Ra, which means PEEK has superior machinability.

  20. Supplemental optical specifications for imaging systems: parameters of phase gradient

    NASA Astrophysics Data System (ADS)

    Xuan, Bin; Li, Jun-Feng; Wang, Peng; Chen, Xiao-Ping; Song, Shu-Mei; Xie, Jing-Jiang

    2009-12-01

    Specifications of phase error, peak to valley (PV), and root mean square (rms) are not able to represent the properties of a wavefront reasonably because of their irresponsibility for spatial frequencies. Power spectral density is a parameter that is especially effective to indicate the frequency regime. However, it seems not convenient for opticians to implement. Parameters of phase gradient, PV gradient, and rms gradient are most correlated with a point-spread function of an imaging system, and they can provide clear instruction of manufacture. The algorithms of gradient parameters have been modified in order to represent the image quality better. In order to demonstrate the analyses, an experimental spherical mirror has been worked out. It is clear that imaging performances can be maintained while manufacture difficulties are decreased when a reasonable trade-off between specifications of phase error and phase gradient is made.

  1. Operational performance of the photovoltaic-powered grain mill and water pump at Tangaye, Upper Volta

    NASA Technical Reports Server (NTRS)

    Martz, J. E.; Ratajczak, A. F.; Delombard, R.

    1982-01-01

    The first two years of operation of a stand alone photovoltaic (PV) power system for the village of Tangaye, Upper Volta in West Africa are described. The purpose of the experiment was to demonstrate that PV systems could provide reliable electrical power for multiple use applications in remote areas where local technical expertise is limited. The 1.8 kW (peak) power system supplies 120-V (d.c.) electrical power to operate a grain mill, a water pump, and mill building lights for the village. The system was initially sized to pump a part of the village water requirements from an existing improved well, and to meet a portion of the village grain grinding requirements. The data, observations, experiences, and conclusions developed during the first two years of operation are discussed. Reports of tests of the mills used in the project are included.

  2. The human brain pacemaker: Synchronized infra-slow neurovascular coupling in patients undergoing non-pulsatile cardiopulmonary bypass.

    PubMed

    Zanatta, Paolo; Toffolo, Gianna Maria; Sartori, Elisa; Bet, Anna; Baldanzi, Fabrizio; Agarwal, Nivedita; Golanov, Eugene

    2013-05-15

    In non-pulsatile cardiopulmonary bypass surgery, middle cerebral artery blood flow velocity (BFV) is characterized by infra-slow oscillations of approximately 0.06Hz, which are paralleled by changes in total EEG power variability (EEG-PV), measured in 2s intervals. Since the origin of these BFV oscillations is not known, we explored their possible causative relationships with oscillations in EEG-PV at around 0.06Hz. We monitored 28 patients undergoing non-pulsatile cardiopulmonary bypass using transcranial Doppler sonography and scalp electroencephalography at two levels of anesthesia, deep (prevalence of burst suppression rhythm) and moderate (prevalence of theta rhythm). Under deep anesthesia, the EEG bursts suppression pattern was highly correlative with BFV oscillations. Hence, a detailed quantitative picture of the coupling between electrical brain activity and BFV was derived, both in deep and moderate anesthesia, via linear and non linear processing of EEG-PV and BFV signals, resorting to widely used measures of signal coupling such as frequency of oscillations, coherence, Granger causality and cross-approximate entropy. Results strongly suggest the existence of coupling between EEG-PV and BFV. In moderate anesthesia EEG-PV mean dominant frequency is similar to frequency of BFV oscillations (0.065±0.010Hz vs 0.045±0.019Hz); coherence between the two signals was significant in about 55% of subjects, and the Granger causality suggested an EEG-PV→BFV causal effect direction. The strength of the coupling increased with deepening anesthesia, as EEG-PV oscillations mean dominant frequency virtually coincided with the BFV peak frequency (0.062±0.017Hz vs 0.060±0.024Hz), and coherence became significant in a larger number (65%) of subjects. Cross-approximate entropy decreased significantly from moderate to deep anesthesia, indicating a higher level of synchrony between the two signals. Presence of a subcortical brain pacemaker that drives vascular infra-slow oscillations in the brain is proposed. These findings allow to suggest an original hypothesis explaining the mechanism underlying infra-slow neurovascular coupling. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pennock, Kenneth; Makarov, Yuri V.; Rajagopal, Sankaran

    The need for proactive closed-loop integration of uncertainty information into system operations and probability-based controls is widely recognized, but rarely implemented in system operations. Proactive integration for this project means that the information concerning expected uncertainty ranges for net load and balancing requirements, including required balancing capacity, ramping and ramp duration characteristics, will be fed back into the generation commitment and dispatch algorithms to modify their performance so that potential shortages of these characteristics can be prevented. This basic, yet important, premise is the motivating factor for this project. The achieved project goal is to demonstrate the benefit of suchmore » a system. The project quantifies future uncertainties, predicts additional system balancing needs including the prediction intervals for capacity and ramping requirements of future dispatch intervals, evaluates the impacts of uncertainties on transmission including the risk of overloads and voltage problems, and explores opportunities for intra-hour generation adjustments helping to provide more flexibility for system operators. The resulting benefits culminate in more reliable grid operation in the face of increased system uncertainty and variability caused by solar power. The project identifies that solar power does not require special separate penetration level restrictions or penalization for its intermittency. Ultimately, the collective consideration of all sources of intermittency distributed over a wide area unified with the comprehensive evaluation of various elements of balancing process, i.e. capacity, ramping, and energy requirements, help system operators more robustly and effectively balance generation against load and interchange. This project showed that doing so can facilitate more solar and other renewable resources on the grid without compromising reliability and control performance. Efforts during the project included developing and integrating advanced probabilistic solar forecasts, including distributed PV forecasts, into closed –loop decision making processes. Additionally, new uncertainty quantifications methods and tools for the direct integration of uncertainty and variability information into grid operations at the transmission and distribution levels were developed and tested. During Phase 1, project work focused heavily on the design, development and demonstration of a set of processes and tools that could reliably and efficiently incorporate solar power into California’s grid operations. In Phase 2, connectivity between the ramping analysis tools and market applications software were completed, multiple dispatch scenarios demonstrated a successful reduction of overall uncertainty and an analysis to quantify increases in system operator reliability, and the transmission and distribution system uncertainty prediction tool was introduced to system operation engineers in a live webinar. The project met its goals, the experiments prove the advancements to methods and tools, when working together, are beneficial to not only the California Independent System Operator, but the benefits are transferable to other system operators in the United States.« less

  4. 26 CFR 49.4253-5 - Exemption for items otherwise taxed.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... otherwise taxed. A dispatch, message, or conversation transmitted by toll telephone, telegraph, or... considered to be one dispatch, message, or conversation, and is subject to only one payment of tax under...

  5. 26 CFR 49.4253-5 - Exemption for items otherwise taxed.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... otherwise taxed. A dispatch, message, or conversation transmitted by toll telephone, telegraph, or... considered to be one dispatch, message, or conversation, and is subject to only one payment of tax under...

  6. Efficient dispatching in a terminal city network

    DOT National Transportation Integrated Search

    2001-01-01

    This report describes new optimization and simulation tools to address several problems in transportation, specifically driver dispatching and tour formation in full truckload trucking. In this segment of transportation industry, one of the problems ...

  7. Best practices in bus dispatch.

    DOT National Transportation Integrated Search

    2012-06-01

    In 2007, the National Center for Transit Research (NCTR) sponsored a study to examine best practices in : extraboard operator management. In most transit agencies, extraboard manpower is managed by the : dispatch function, but extraboard management i...

  8. Evaluation of Human Reliability in Selected Activities in the Railway Industry

    NASA Astrophysics Data System (ADS)

    Sujová, Erika; Čierna, Helena; Molenda, Michał

    2016-09-01

    The article focuses on evaluation of human reliability in the human - machine system in the railway industry. Based on a survey of a train dispatcher and of selected activities, we have identified risk factors affecting the dispatcher`s work and the evaluated risk level of their influence on the reliability and safety of preformed activities. The research took place at the authors` work place between 2012-2013. A survey method was used. With its help, authors were able to identify selected work activities of train dispatcher's risk factors that affect his/her work and the evaluated seriousness of its influence on the reliability and safety of performed activities. Amongst the most important finding fall expressions of unclear and complicated internal regulations and work processes, a feeling of being overworked, fear for one's safety at small, insufficiently protected stations.

  9. Robust optimization-based DC optimal power flow for managing wind generation uncertainty

    NASA Astrophysics Data System (ADS)

    Boonchuay, Chanwit; Tomsovic, Kevin; Li, Fangxing; Ongsakul, Weerakorn

    2012-11-01

    Integrating wind generation into the wider grid causes a number of challenges to traditional power system operation. Given the relatively large wind forecast errors, congestion management tools based on optimal power flow (OPF) need to be improved. In this paper, a robust optimization (RO)-based DCOPF is proposed to determine the optimal generation dispatch and locational marginal prices (LMPs) for a day-ahead competitive electricity market considering the risk of dispatch cost variation. The basic concept is to use the dispatch to hedge against the possibility of reduced or increased wind generation. The proposed RO-based DCOPF is compared with a stochastic non-linear programming (SNP) approach on a modified PJM 5-bus system. Primary test results show that the proposed DCOPF model can provide lower dispatch cost than the SNP approach.

  10. Cluster analyses of association of weather, daily factors and emergent medical conditions.

    PubMed

    Malkić, Jasmin; Sarajlić, Nermin; Smrke, Barbara U R; Smrke, Dragica

    2013-03-01

    The goal of this study was to evaluate associations between the meteorological conditions and the number of emergency cases for five distinctive causes of dispatch groups reported to SOS dispatch centre in Uppsala, Sweden. Center's responsibility include alerting to 17 ambulances in whole Uppsala County, area of 8,209 km2 with around 320,000 inhabitants representing the target patient group. Source of the medical data for this study is the database of dispatch data for the year of 2009, while the metrological data have been provided from Uppsala University Department of Earth Sciences yearly weather report. Medical and meteorological data were summoned into the unified data space where each point represents a day with its weather parameters and dispatch cause group cardinality. DBSCAN data mining algorithm was implemented to five distinctive groups of dispatch causes after the data spaces have gone through the variance adjustment and the principal component analyses. As the result, several point clusters were discovered in each of the examined data spaces indicating the distinctive conditions regarding the weather and daily cardinality of the dispatch cause, as well as the associations between these two. Most interesting finding is that specific type of winter weather formed a cluster only around the days with the high count of breathing difficulties, while one of the summer weather clusters made similar association with the days with low number of cases. Findings were confirmed by confidence level estimation based on signal to noise ratio for the observed data points.

  11. A coordination theory for intelligent machines

    NASA Technical Reports Server (NTRS)

    Wang, Fei-Yue; Saridis, George N.

    1990-01-01

    A formal model for the coordination level of intelligent machines is established. The framework of the coordination level investigated consists of one dispatcher and a number of coordinators. The model called coordination structure has been used to describe analytically the information structure and information flow for the coordination activities in the coordination level. Specifically, the coordination structure offers a formalism to (1) describe the task translation of the dispatcher and coordinators; (2) represent the individual process within the dispatcher and coordinators; (3) specify the cooperation and connection among the dispatcher and coordinators; (4) perform the process analysis and evaluation; and (5) provide a control and communication mechanism for the real-time monitor or simulation of the coordination process. A simple procedure for the task scheduling in the coordination structure is presented. The task translation is achieved by a stochastic learning algorithm. The learning process is measured with entropy and its convergence is guaranteed. Finally, a case study of the coordination structure with three coordinators and one dispatcher for a simple intelligent manipulator system illustrates the proposed model and the simulation of the task processes performed on the model verifies the soundness of the theory.

  12. Best practices in bus dispatch [summary].

    DOT National Transportation Integrated Search

    2012-01-01

    In 2007, the National Center for Transit Research : sponsored a study of best practices in extraboard : operator management, finding that in most transit : agencies, extraboard manpower is managed by : dispatchers as one of their many functions. This...

  13. Effects of strabismic amblyopia and strabismus without amblyopia on visuomotor behavior: III. Temporal eye-hand coordination during reaching.

    PubMed

    Niechwiej-Szwedo, Ewa; Goltz, Herbert C; Chandrakumar, Manokaraananthan; Wong, Agnes M F

    2014-11-11

    To examine the effects of strabismic amblyopia and strabismus only, without amblyopia, on the temporal patterns of eye-hand coordination during both the planning and execution stages of visually-guided reaching. Forty-six adults (16 with strabismic amblyopia, 14 with strabismus only, and 16 visually normal) executed reach-to-touch movements toward targets presented randomly 5° or 10° to the left or right of central fixation. Viewing conditions were binocular, monocular viewing with the amblyopic eye, and monocular viewing with the fellow eye (dominant and nondominant viewing for participants without amblyopia). Temporal coordination between eye and hand movements was examined during reach planning (interval between the initiation of saccade and reaching, i.e., saccade-to-reach planning interval) and reach execution (interval between the initiation of saccade and reach peak velocity [PV], i.e., saccade-to-reach PV interval). The frequency and dynamics of secondary reach-related saccades were also examined. The temporal patterns of eye-hand coordination prior to reach initiation were comparable among participants with strabismic amblyopia, strabismus only, and visually normal adults. However, the reach acceleration phase of participants with strabismic amblyopia and those with strabismus only were longer following target fixation (saccade-to-reach PV interval) than that of visually normal participants (P < 0.05). This effect was evident under all viewing conditions. The saccade-to-reach planning interval and the saccade-to-reach PV interval were not significantly different among participants with amblyopia with different levels of acuity and stereo acuity loss. Participants with strabismic amblyopia and strabismus only initiated secondary reach-related saccades significantly more frequently than visually normal participants. The amplitude and peak velocity of these saccades were significantly greater during amblyopic eye viewing in participants with amblyopia who also had negative stereopsis. Adults with strabismic amblyopia and strabismus only showed an altered pattern of temporal eye-hand coordination during the reach acceleration phase, which might affect their ability to modify reach trajectory using early online control. Secondary reach-related saccades may provide a compensatory mechanism with which to facilitate the late online control process in order to ensure relatively good reaching performance during binocular and fellow eye viewing. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  14. A review on economic emission dispatch problems using quantum computational intelligence

    NASA Astrophysics Data System (ADS)

    Mahdi, Fahad Parvez; Vasant, Pandian; Kallimani, Vish; Abdullah-Al-Wadud, M.

    2016-11-01

    Economic emission dispatch (EED) problems are one of the most crucial problems in power systems. Growing energy demand, limitation of natural resources and global warming make this topic into the center of discussion and research. This paper reviews the use of Quantum Computational Intelligence (QCI) in solving Economic Emission Dispatch problems. QCI techniques like Quantum Genetic Algorithm (QGA) and Quantum Particle Swarm Optimization (QPSO) algorithm are discussed here. This paper will encourage the researcher to use more QCI based algorithm to get better optimal result for solving EED problems.

  15. Advances in Plexcore active layer technology systems for organic photovoltaics: roof-top and accelerated lifetime analysis of high performance organic photovoltaic cells

    NASA Astrophysics Data System (ADS)

    Laird, Darin W.; Vaidya, Swanand; Li, Sergey; Mathai, Mathew; Woodworth, Brian; Sheina, Elena; Williams, Shawn; Hammond, Troy

    2007-09-01

    We report NREL-certified efficiencies and initial lifetime data for organic photovoltaic (OPV) cells based on Plexcore PV photoactive layer and Plexcore HTL-OPV hole transport layer technology. Plexcore PV-F3, a photoactive layer OPV ink, was certified in a single-layer OPV cell at the National Renewable Energy Laboratory (NREL) at 5.4%, which represents the highest official mark for a single-layer organic solar cell. We have fabricated and measured P3HT:PCBM solar cells with a peak efficiency of 4.4% and typical efficiencies of 3 - 4% (internal, NREL-calibrated measurement) with P3HT manufactured at Plextronics by the Grignard Metathesis (GRIM) method. Outdoor and accelerated lifetime testing of these devices is reported. Both Plexcore PV-F3 and P3HT:PCBM-based OPV cells exhibit >750 hours of outdoor roof-top, non-accelerated lifetime with less than 8% loss in initial efficiency for both active layer systems when exposed continuously to the climate of Western Pennsylvania. These devices are continuously being tested to date. Accelerated testing using a high-intensity (1000W) metal-halide lamp affords shorter lifetimes; however, the true acceleration factor is still to be determined.

  16. A High Pressure Post-Perovskite Phase Transition in NaMgF3--a MgSiO3 Analog Material

    NASA Astrophysics Data System (ADS)

    Martin, C.; Liu, H.; Crichton, W.; Parise, J. B.

    2005-12-01

    Since Murakami et al. (2004) identified a perovskite (pv, Pbnm) to post-perovskite (ppv, Cmcm) structural phase transition in MgSiO3, the transition has been reported to occur in many oxides at ultra-high pressures (>60 GPa). The layered ppv structure is rapidly shaping a better understanding of seismic anisotropy in the controversial D" region of the lower mantle. While the ppv unit cell may be derived from indexing of the powder pattern, the structure adopted at high pressure is experimentally ill-constrained due to compromised powder diffraction statistics typically obtained from small sample volumes at extreme conditions in the diamond anvil cell. NaMgF3, a structural analog material to MgSiO3 pv, exhibits a large compressibility and presents the possibility of reducing the pv-ppv transition pressure, allowing for improved powder statistics from a larger sample volume. In accordance with our previous theoretical and experimental evidence (Liu et al., 2005; Parise et al., 2004), we have observed a phase transition in NaMgF3 during two recent independent high pressure trials utilizing monochromatic x-ray diffraction and in-situ laser heating in the diamond anvil cell at pressures as low as 30 GPa. From our analysis thus far, we have found the unit cell of the high pressure phase cannot be indexed according to pv (Pbnm) or close permutations of ppv (Cmcm) unit cells predicted for NaMgF3 or unit cells observed for ppv MgSiO3 and MgGeO3. In addition, we have precluded a breakdown to high pressure phases of NaF and MgF3 as an explanation for the observed data. Upon pressure release, we observe diffraction peaks from the high pressure phase in the absence of pv NaMgF3, suggesting the high pressure structure is quenchable to ambient conditions. The results of the work in progress will be presented at the meeting.

  17. Reliability and Validity Assessment of a Linear Position Transducer

    PubMed Central

    Garnacho-Castaño, Manuel V.; López-Lastra, Silvia; Maté-Muñoz, José L.

    2015-01-01

    The objectives of the study were to determine the validity and reliability of peak velocity (PV), average velocity (AV), peak power (PP) and average power (AP) measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain) during two resistance exercises, bench press (BP) and full back squat (BS), performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2). Intraclass correlation coefficients (ICCs) indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W). Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W). Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP) make this device a useful tool for monitoring resistance training. Key points This study determined the validity and reliability of peak velocity, average velocity, peak power and average power measurements made using a linear position transducer The Tendo Weight-lifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and power. PMID:25729300

  18. Acute Effects of Elastic Bands on Kinetic Characteristics During the Deadlift at Moderate and Heavy Loads.

    PubMed

    Galpin, Andrew J; Malyszek, Kylie K; Davis, Kyle A; Record, Shaina M; Brown, Lee E; Coburn, Jared W; Harmon, RoQue A; Steele, Jeff M; Manolovitz, Adam D

    2015-12-01

    Loading a barbell with variable resistance positively alters kinetic characteristics during the back squat and bench press but has never been studied during the deadlift. The purpose of this project was to examine the acute effects of combining elastic bands and free weights during the deadlift at moderate and heavy loads. Twelve trained men (age: 24.08 ± 2.35 years, height: 175.94 ± 5.38 cm, mass: 85.58 ± 12.49 kg, deadlift 1 repetition maximum (RM): 188.64 ± 16.13 kg) completed 2 variable resistance (B1 and B2) and 1 traditional free-weight (NB) condition at both 60 and 85% 1RM on a force plate. B1 had 15% resistance from bands, with the remaining 85% from free weights. B2 had 35% bands and 65% free weights. NB used free weights only. Average resistance was equated for all conditions. Power and velocity generally increased, whereas force decreased with the addition of bands. The amount of band tension (B1 or B2) had little impact on power when lifting at 60% 1RM. However, greater resistance from bands resulted in greater peak and relative power when lifting at 85% 1RM. Adding elastic bands decreased time to peak force (PF), time between PF and peak power (PP), and time between PF and peak velocity (PV) when compared with NB at 60% 1RM (NB > B1 > B2). These differences only reached significance for NB > B2 when lifting at 85% 1RM. These same differences existed for time between PP and PV. Thus, the amount of tension from bands has less impact on interpeak variables at heavier absolute loads. Practitioners should consider using heavy bands when prescribing the deadlift for speed or power, but not maximal force.

  19. Evaluation of a Dispatcher's Route Optimization Decision Aid to Avoid Aviation Weather Hazards

    NASA Technical Reports Server (NTRS)

    Dorneich, Michael C.; Olofinboba, Olu; Pratt, Steve; Osborne, Dannielle; Feyereisen, Thea; Latorella, Kara

    2003-01-01

    This document describes the results and analysis of the formal evaluation plan for the Honeywell software tool developed under the NASA AWIN (Aviation Weather Information) 'Weather Avoidance using Route Optimization as a Decision Aid' project. The software tool aims to provide airline dispatchers with a decision aid for selecting optimal routes that avoid weather and other hazards. This evaluation compares and contrasts route selection performance with the AWIN tool to that of subjects using a more traditional dispatcher environment. The evaluation assesses gains in safety, in fuel efficiency of planned routes, and in time efficiency in the pre-flight dispatch process through the use of the AWIN decision aid. In addition, we are interested in how this AWIN tool affects constructs that can be related to performance. The construct of Situation Awareness (SA), workload, trust in an information system, and operator acceptance are assessed using established scales, where these exist, as well as through the evaluation of questionnaire responses and subject comments. The intention of the experiment is to set up a simulated operations area for the dispatchers to work in. They will be given scenarios in which they are presented with stored company routes for a particular city-pair and aircraft type. A diverse set of external weather information sources is represented by a stand-alone display (MOCK), containing the actual historical weather data typically used by dispatchers. There is also the possibility of presenting selected weather data on the route visualization tool. The company routes have not been modified to avoid the weather except in the case of one additional route generated by the Honeywell prototype flight planning system. The dispatcher will be required to choose the most appropriate and efficient flight plan route in the displayed weather conditions. The route may be modified manually or may be chosen from those automatically displayed.

  20. Real-time pricing strategy of micro-grid energy centre considering price-based demand response

    NASA Astrophysics Data System (ADS)

    Xu, Zhiheng; Zhang, Yongjun; Wang, Gan

    2017-07-01

    With the development of energy conversion technology such as power to gas (P2G), fuel cell and so on, the coupling between energy sources becomes more and more closely. Centralized dispatch among electricity, natural gas and heat will become a trend. With the goal of maximizing the system revenue, this paper establishes the model of micro-grid energy centre based on energy hub. According to the proposed model, the real-time pricing strategy taking into account price-based demand response of load is developed. And the influence of real-time pricing strategy on the peak load shifting is discussed. In addition, the impact of wind power predicted inaccuracy on real-time pricing strategy is analysed.

  1. Airline Transport Pilot, Aircraft Dispatcher, and Flight Navigator Knowledge Test Guide

    DOT National Transportation Integrated Search

    1995-01-01

    The Flight Standards Service of the Federal Aviation Administration (FAA) has developed this guide to help applicants meet the knowledge requirements for airline transport pilot, aircraft dispatcher, and flight navigator certification. This guide con...

  2. Aircraft Dispatcher - Practical Test Standards

    DOT National Transportation Integrated Search

    1995-06-01

    The Flight Standards Service of the FAA has developed this practical : test book as a standard to be used by FAA inspectors and designated : examiners when conducting the aircraft dispatcher practical test. : Instructors are expected to use this book...

  3. A Cost-Effective Electric Vehicle Charging Method Designed For Residential Homes with Renewable Energy

    NASA Astrophysics Data System (ADS)

    Lie, T. T.; Liang, Xiuli; Haque, M. H.

    2015-03-01

    Most of the electrical infrastructure in use around the world today is decades old, and may be illsuited to widespread proliferation of personal Electric Vehicles (EVs) whose charging requirements will place increasing strain on grid demand. In order to reduce the pressure on the grid and taking benefits of off peak charging, this paper presents a smart and cost effective EV charging methodology for residential homes equipped with renewable energy resources such as Photovoltaic (PV) panels and battery. The proposed method ensures slower battery degradation and prevents overcharging. The performance of the proposed algorithm is verified by conducting simulation studies utilizing running data of Nissan Altra. From the simulation study results, the algorithm is shown to be effective and feasible which minimizes not only the charging cost but also can shift the charging time from peak value to off-peak time.

  4. Design of a cooperative problem-solving system for enroute flight planning: An empirical study of its use by airline dispatchers

    NASA Technical Reports Server (NTRS)

    Smith, Philip J.; Mccoy, C. Elaine; Layton, Charles; Orasanu, Judith; Chappel, Sherry; Palmer, EV; Corker, Kevin

    1993-01-01

    In a previous report, an empirical study of 30 pilots using the Flight Planning Testbed was reported. An identical experiment using the Flight Planning Testbed (FPT), except that 27 airline dispatchers were studied, is described. Five general questions were addressed in this study: (1) under what circumstances do the introduction of computer-generated suggestions (flight plans) influence the planning behavior of dispatchers (either in a beneficial or adverse manner); (2) what is the nature of such influences (i.e., how are the person's cognitive processes changed); (3) how beneficial are the general design concepts underlying FPT (use of a graphical interface, embedding graphics in a spreadsheet, etc.); (4) how effective are the specific implementation decisions made in realizing these general design concepts; and (5) how effectively do dispatchers evaluate situations requiring replanning, and how effectively do they identify appropriate solutions to these situations.

  5. Isolation, characterization and cloning of a cDNA encoding a new antifungal defensin from Phaseolus vulgaris L. seeds.

    PubMed

    Games, Patrícia D; Dos Santos, Izabela S; Mello, Erica O; Diz, Mariângela S S; Carvalho, André O; de Souza-Filho, Gonçalo A; Da Cunha, Maura; Vasconcelos, Ilka M; Ferreira, Beatriz Dos S; Gomes, Valdirene M

    2008-12-01

    The PvD1 defensin was purified from Phaseolus vulgaris (cv. Pérola) seeds, basically as described by Terras et al. [Terras FRG, Schoofs HME, De Bolle MFC, Van Leuven F, Ress SB, Vanderleyden J, Cammue BPA, Broekaer TWF. Analysis of two novel classes of plant antifungal proteins from radish (Raphanus sativus L.) seeds. J Biol Chem 1992;267(22):15301-9], with some modifications. A DEAE-Sepharose, equilibrated with 20mM Tris-HCl, pH 8.0, was initially utilized for the separation of peptides after ammonium sulfate fractionation. The basic fraction (the non-retained peak) obtained showed the presence of one unique band in SDS-Tricine gel electrophoresis with a molecular mass of approximately 6kDa. The purification of this peptide was confirmed after a reverse-phase chromatography in a C2/C18 column by HPLC, where once again only one peak was observed and denominated H1. H1 was submitted to N-terminal sequencing and the comparative analysis in databanks revealed high similarity with sequences of different defensins isolated from other plants species. The N-terminal sequence of the mature defensin isolated was used to produce a degenerated primer. This primer allowed the amplification of the defensin cDNA by RT-PCR from mRNA of P. vulgaris seeds. The sequence analysis of the cloned cDNA, named PVD1, demonstrated 314bp encoding a polypeptide of 47 amino acids. The deduced peptide presented high similarity with plant defensins of Vigna unguiculata (93%), Cicer arietinum (95%) and Pachyrhizus erosus (87%). PvD1 inhibited the growth of the yeasts, Candida albicans, Candida parapsilosis, Candida tropicalis, Candida guilliermondii, Kluyveromyces marxiannus and Saccharomyces cerevisiae. PvD1 also presented an inhibitory activity against the growth of phytopathogenic fungi including Fusarium oxysporum, Fusarium solani, Fusarium lateritium and Rizoctonia solani.

  6. The impacts of electricity dispatch protocols on the emission reductions due to wind power and carbon tax.

    PubMed

    Yu, Yang; Rajagopal, Ram

    2015-02-17

    Two dispatch protocols have been adopted by electricity markets to deal with the uncertainty of wind power but the effects of the selection between the dispatch protocols have not been comprehensively analyzed. We establish a framework to compare the impacts of adopting different dispatch protocols on the efficacy of using wind power and implementing a carbon tax to reduce emissions. We suggest that a market has high potential to achieve greater emission reduction by adopting the stochastic dispatch protocol instead of the static protocol when the wind energy in the market is highly uncertain or the market has enough adjustable generators, such as gas-fired combustion generators. Furthermore, the carbon-tax policy is more cost-efficient for reducing CO2 emission when the market operates according to the stochastic protocol rather than the static protocol. An empirical study, which is calibrated according to the data from the Electric Reliability Council of Texas market, confirms that using wind energy in the Texas market results in a 12% CO2 emission reduction when the market uses the stochastic dispatch protocol instead of the 8% emission reduction associated with the static protocol. In addition, if a 6$/ton carbon tax is implemented in the Texas market operated according to the stochastic protocol, the CO2 emission is similar to the emission level from the same market with a 16$/ton carbon tax operated according to the static protocol. Correspondingly, the 16$/ton carbon tax associated with the static protocol costs 42.6% more than the 6$/ton carbon tax associated with the stochastic protocol.

  7. A Feeder-Bus Dispatch Planning Model for Emergency Evacuation in Urban Rail Transit Corridors

    PubMed Central

    Wang, Yun; Yan, Xuedong; Zhou, Yu; Zhang, Wenyi

    2016-01-01

    The mobility of modern metropolises strongly relies on urban rail transit (URT) systems, and such a heavy dependence causes that even minor service interruptions would make the URT systems unsustainable. This study aims at optimally dispatching the ground feeder-bus to coordinate with the urban rails’ operation for eliminating the effect of unexpected service interruptions in URT corridors. A feeder-bus dispatch planning model was proposed for the collaborative optimization of URT and feeder-bus cooperation under emergency situations and minimizing the total evacuation cost of the feeder-buses. To solve the model, a concept of dummy feeder-bus system is proposed to transform the non-linear model into traditional linear programming (ILP) model, i.e., traditional transportation problem. The case study of Line #2 of Nanjing URT in China was adopted to illustrate the model application and sensitivity analyses of the key variables. The modeling results show that as the evacuation time window increases, the total evacuation cost as well as the number of dispatched feeder-buses decrease, and the dispatched feeder-buses need operate for more times along the feeder-bus line. The number of dispatched feeder-buses does not show an obvious change with the increase of parking spot capacity and time window, indicating that simply increasing the parking spot capacity would cause huge waste for the emergent bus utilization. When the unbalanced evacuation demand exists between stations, the more feeder-buses are needed. The method of this study will contribute to improving transportation emergency management and resource allocation for URT systems. PMID:27676179

  8. Development of a surveillance case definition for heat-related illness using 911 medical dispatch data.

    PubMed

    Bassil, Kate L; Cole, Donald C; Moineddin, Rahim; Gournis, Effie; Schwartz, Brian; Craig, Alan M; Lou, W Y Wendy; Rea, Elizabeth

    2008-01-01

    The adverse effects of hot weather on public health are of increasing concern. A surveillance system using 911 medical dispatch data for the detection of heat-related illness (HRI) could provide new information on the impact of excessive heat on the population. This paper describes how we identified medical dispatch call codes, called "determinants", that could represent HRI events. Approximately 500 medical dispatch determinants were reviewed in focus groups composed of Emergency Medical Services (EMS) paramedics, dispatchers, physicians, and public health epidemiologists. Each group was asked to select those determinants that might adequately represent HRI. Selections were then assessed empirically using correlations with daily mean temperature over the study period (June 1-August 31,2005). The focus groups identified 12 determinant groupings and ranked them according to specificity for HRI. Of these, "Heat/cold exposure" was deemed the most specific. The call determinant groupings with the clearest positive associations with daily mean temperature empirically were "Heat/cold exposure" (Spearman's correlation coefficient (SCC) 0.71, p < 0.0001) and "Unknown problem (man down)" (SCC 0.21, p = 0.04). Within each grouping, the determinant "Unknown status (3rd party caller)" showed significant associations, SCC = 0.34 (p = 0.001) and SCC = 0.22 (p = 0.03) respectively. Clinically-informed expertise and empirical evidence both contributed to identification of a group of 911 medical dispatch call determinants that plausibly represent HRI events. Once evaluated prospectively, these may be used in public health surveillance to better understand environmental health impacts on human populations and inform targeted public health interventions.

  9. Alternatives to Traditional EMS Dispatch and Transport: A Scoping Review of Reported Outcomes.

    PubMed

    Jensen, Jan L; Carter, Alix J E; Rose, Jennifer; Visintini, Sarah; Bourdon, Emmanuelle; Brown, Ryan; McVey, Jennifer; Travers, Andrew H

    2015-09-01

    Emergency medical services (EMS) programs, which provide an alternative to traditional EMS dispatch or transport to the emergency department (ED), are becoming widely implemented. This scoping review identified and catalogued all outcomes used to measure such alternative EMS programs. Data Source Broad systematized bibliographic and grey literature searches were conducted. Study Selection Inclusion criteria were 911 callers/EMS patients, reported on alternatives to traditional EMS dispatch OR traditional EMS transport to the ED, and reported an outcome measure. Data Extraction The reports were categorized as either alternative to dispatch or to EMS transport, and outcome measures were categorized and described. Data Synthesis The bibliographic search retrieved 13,215 records, of which 34 articles met the inclusion criteria, with an additional 10 added from reference list hand-searching (n=44 included). In the grey literature search, 31 websites were identified, from which four met criteria and were retrieved (n=4 included). Fifteen reports (16 studies) described alternatives to EMS dispatch, and 33 reports described alternatives to EMS transport. The most common outcomes reported in the alternatives to EMS dispatch reports were service utilization and decision accuracy. Twenty-four different specific outcomes were reported. The most common outcomes reported in the alternatives to EMS transport reports were service utilization and safety, and 50 different specific outcomes were reported. Numerous outcome measures were identified in reports of alternative EMS programs, which were catalogued and described. Researchers and program leaders should achieve consensus on uniform outcome measures, to allow benchmarking and improve comparison across programs.

  10. The linguistic and interactional factors impacting recognition and dispatch in emergency calls for out-of-hospital cardiac arrest: a mixed-method linguistic analysis study protocol

    PubMed Central

    Riou, Marine; Ball, Stephen; Williams, Teresa A; Whiteside, Austin; O’Halloran, Kay L; Bray, Janet; Perkins, Gavin D; Cameron, Peter; Fatovich, Daniel M; Inoue, Madoka; Bailey, Paul; Brink, Deon; Smith, Karen; Della, Phillip; Finn, Judith

    2017-01-01

    Introduction Emergency telephone calls placed by bystanders are crucial to the recognition of out-of-hospital cardiac arrest (OHCA), fast ambulance dispatch and initiation of early basic life support. Clear and efficient communication between caller and call-taker is essential to this time-critical emergency, yet few studies have investigated the impact that linguistic factors may have on the nature of the interaction and the resulting trajectory of the call. This research aims to provide a better understanding of communication factors impacting on the accuracy and timeliness of ambulance dispatch. Methods and analysis A dataset of OHCA calls and their corresponding metadata will be analysed from an interdisciplinary perspective, combining linguistic analysis and health services research. The calls will be transcribed and coded for linguistic and interactional variables and then used to answer a series of research questions about the recognition of OHCA and the delivery of basic life-support instructions to bystanders. Linguistic analysis of calls will provide a deeper understanding of the interactional dynamics between caller and call-taker which may affect recognition and dispatch for OHCA. Findings from this research will translate into recommendations for modifications of the protocols for ambulance dispatch and provide directions for further research. Ethics and dissemination The study has been approved by the Curtin University Human Research Ethics Committee (HR128/2013) and the St John Ambulance Western Australia Research Advisory Group. Findings will be published in peer-reviewed journals and communicated to key audiences, including ambulance dispatch professionals. PMID:28694349

  11. Optimized dispatch in a first-principles concentrating solar power production model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, Michael J.; Newman, Alexandra M.; Hamilton, William T.

    Concentrating solar power towers, which include a steam-Rankine cycle with molten salt thermal energy storage, is an emerging technology whose maximum effectiveness relies on an optimal operational and dispatch policy. Given parameters such as start-up and shut-down penalties, expected electricity price profiles, solar availability, and system interoperability requirements, this paper seeks a profit-maximizing solution that determines start-up and shut-down times for the power cycle and solar receiver, and the times at which to dispatch stored and instantaneous quantities of energy over a 48-h horizon at hourly fidelity. The mixed-integer linear program (MIP) is subject to constraints including: (i) minimum andmore » maximum rates of start-up and shut-down, (ii) energy balance, including energetic state of the system as a whole and its components, (iii) logical rules governing the operational modes of the power cycle and solar receiver, and (iv) operational consistency between time periods. The novelty in this work lies in the successful integration of a dispatch optimization model into a detailed techno-economic analysis tool, specifically, the National Renewable Energy Laboratory's System Advisor Model (SAM). The MIP produces an optimized operating strategy, historically determined via a heuristic. Using several market electricity pricing profiles, we present comparative results for a system with and without dispatch optimization, indicating that dispatch optimization can improve plant profitability by 5-20% and thereby alter the economics of concentrating solar power technology. While we examine a molten salt power tower system, this analysis is equally applicable to the more mature concentrating solar parabolic trough system with thermal energy storage.« less

  12. 49 CFR 241.9 - Prohibition against extraterritorial dispatching; exceptions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... emergency situation, a railroad may require or permit one of its dispatchers located outside the United... or by electronic mail. (3) A list of the States that make up the FRA regions and the street and e...

  13. Task Decomposition Model for Dispatchers in Dynamic Scheduling of Demand Responsive Transit Systems

    DOT National Transportation Integrated Search

    2000-06-01

    Since the passage of ADA, the demand for paratransit service is steadily increasing. Paratransit companies are relying on computer automation to streamline dispatch operations, increase productivity and reduce operator stress and error. Little resear...

  14. Impact of data link technology on railroad dispatching operations

    DOT National Transportation Integrated Search

    2004-10-01

    This study examined data link communication as an alternative channel to voice radio for railroad dispatchers. The goal was to compare how data link affected performance compared to voice radio only communications on measures related to safety, produ...

  15. SMART operational field test evaluation : dispatchers survey report : final report

    DOT National Transportation Integrated Search

    1997-06-01

    The Suburban Mobility Authority for Regional Transportation (SMART) has installed an automaticscheduling and dispatch system (ASD) in Southeast Michigan in accordance with their plans toimplement ITS as a site for an operational field test. The purpo...

  16. An analysis of the job of railroad train dispatcher.

    DOT National Transportation Integrated Search

    1974-04-01

    This report constitutes a detailed study of the job of railroad train dispatcher, conducted to provide a data base for the derivation of criteria of job knowledge, skills and training consonant with safe operations. Documentation was reviewed; specia...

  17. Solar Thermoelectricity via Advanced Latent Heat Storage: A Cost-Effective Small-Scale CSP Application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glatzmaier, Greg C.; Rea, J.; Olsen, Michele L.

    We are developing a novel concentrating solar electricity-generating technology that is both modular and dispatchable. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) uses concentrated solar flux to generate high-temperature thermal energy, which directly converts to electricity via thermoelectric generators (TEGs), stored within a phase-change material (PCM) for electricity generation at a later time, or both allowing for simultaneous charging of the PCM and electricity generation. STEALS has inherent features that drive its cost-competitive scale to be much smaller than current commercial concentrating solar power (CSP) plants. Most obvious is modularity of the solid-state TEG, which favors smaller scales inmore » the kilowatt range as compared to CSP steam turbines, which are minimally 50 MWe for commercial power plants. Here, we present techno-economic and market analyses that show STEALS can be a cost-effective electricity-generating technology with particular appeal to small-scale microgrid applications. We evaluated levelized cost of energy (LCOE) for STEALS and for a comparable photovoltaic (PV) system with battery storage. For STEALS, we estimated capital costs and the LCOE as functions of the type of PCM including the use of recycled aluminum alloys, and evaluated the cost tradeoffs between plasma spray coatings and solution-based boron coatings that are applied to the wetted surfaces of the PCM subsystem. We developed a probabilistic cost model that accounts for uncertainties in the cost and performance inputs to the LCOE estimation. Our probabilistic model estimated LCOE for a 100-kWe STEALS system that had 5 hours of thermal storage and 8-10 hours of total daily power generation. For these cases, the solar multiple for the heliostat field varied between 1.12 and 1.5. We identified microgrids as a likely market for the STEALS system. We characterized microgrid markets in terms of nominal power, dispatchability, geographic location, and customer type, and specified additional features for STEALS that are needed to meet the needs of this growing power market.« less

  18. Treatment of cardiac arrest with rapid defibrillation by police in King County, Washington.

    PubMed

    Becker, Linda; Husain, Sofia; Kudenchuk, Peter; Doll, Ann; Rea, Tom; Eisenberg, Mickey

    2014-01-01

    Improving survival from out-of-hospital cardiac arrest is an ongoing challenge for emergency medical services (EMS). Various strategies for shortening the time from collapse to defibrillation have been used, and one is to equip police officers with defibrillators. Objective. We evaluated the programmatic implementation of police defibrillation to determine if such a program could improve the process of care in a high-functioning and mature EMS system. We conducted a prospective observational study of implementation of a police defibrillation in two police departments in King County, Washington, from March 1, 2010 to March 31, 2012. The program was designed to dispatch police specifically to cases with a high suspicion of cardiac arrest, defined as a patient who was unconscious and not breathing normally. We included all nontraumatic out-of-hospital cardiac arrest events that occurred prior to EMS arrival and within the city limits of the two cities. We collected both EMS and police dispatch reports to document times of call receipt, dispatch, and arrival of both agencies. We obtained rhythm recordings when the automated external defibrillators (AEDs) were used by the police. Descriptive statistics were used to measure frequency of police dispatch and to compare times to treatment between patients with a police response and those without. During the study period there were 231 cases of cardiac arrest that occurred prior to EMS arrival eligible for police response in the study communities. Police were dispatched to 124 (54%) of these cases. Of the 124, the police arrived before EMS 37 times, or 16% of the 231 cases. Police performed CPR in 29 of these cases and applied the AED in 21 of them. Of the 21 cases in which the AED was applied for cardiac arrest, a shock was delivered on first analysis for 6 patients. Although the response interval between dispatch to scene arrival was similar for EMS and police (4.5 minutes versus 4.6 minutes respectively, p = 0.08), police were dispatched considerably slower than EMS (1.8 minutes versus 0.6 minutes, p < 0.001). In the current programmatic implementation, police had a measurable but limited involvement in resuscitation. Efforts to address dispatch challenges may improve police involvement.

  19. Remote Sensing of the Environmental Impacts of Utility-Scale Solar Energy Plants

    NASA Astrophysics Data System (ADS)

    Edalat, Mohammad Masih

    Solar energy has many environmental benefits compared with fossil fuels but solar farming can have environmental impacts especially during construction and development. Thus, in order to enhance environmental sustainability, it is imperative to understand the environmental impacts of utility-scale solar energy (USSE) plants. During recent decades, remote sensing techniques and geographic information systems have become standard techniques in environmental applications. In this study, the environmental impacts of USSE plants are investigated by analyzing changes to land surface characteristics using remote sensing. The surface characteristics studied include land cover, land surface temperature, and hydrological response whereas changes are mapped by comparing pre-, syn-, and post- construction conditions. In order to study the effects of USSE facilities on land cover, the changes in the land cover are measured and analyzed inside and around two USSE facilities. The principal component analysis (PCA), minimum noise fraction (MNF), and spectral mixture analysis (SMA) of remote sensing images are used to estimate the subpixel fraction of four land surface endmembers: high-albedo, low-albedo, shadow, and vegetation. The results revealed that USSE plants do not significantly impact land cover outside the plant boundary. However, land-cover radiative characteristics within the plant area are significantly affected after construction. During the construction phase, site preparation practices including shrub removal and land grading increase high-albedo and decrease low-albedo fractions. The thermal effects of USSE facilities are studied by the time series analysis of remote sensing land surface temperature (LST). A statistical trend analysis of LST, with seasonal trends removed is performed with a particular consideration of panel shadowing by analyzing sun angles for different times of year. The results revealed that the LST outside the boundary of the solar plant does not change, whereas it significantly decreases inside the plant at 10 AM after the construction. The decrease in LST mainly occurred in winters due to lower sun's altitude, which casts longer shadows on the ground. In order to study the hydrological impacts of PV plants, pre- and post-installation hydrological response over single-axis technology is compared. A theoretical reasoning is developed to explain flows under the influence of PV panels. Moreover, a distributed parametric hydrologic model is used to estimate runoff before and after the construction of PV plants. The results revealed that peak flow, peak flow time, and runoff volume alter after panel installation. After panel installation, peak flow decreases and is observed to shift in time, which depends on orientation. Likewise, runoff volume increases irrespective of panel orientation. The increase in the tilt angle of panel results in decrease in the peak flow, peak flow time, and runoff. This study provides an insight into the environmental impacts of USSE development using remote sensing. The research demonstrates that USSE plants are environmentally sustainable due to minimal impact on land cover and surface temperature in their vicinity. In addition, this research explains the role of rainfall shadowing on hydrological behavior at USSE plants.

  20. Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat.

    PubMed

    Banyard, Harry G; Nosaka, Ken; Sato, Kimitake; Haff, G Gregory

    2017-10-01

    To examine the validity of 2 kinematic systems for assessing mean velocity (MV), peak velocity (PV), mean force (MF), peak force (PF), mean power (MP), and peak power (PP) during the full-depth free-weight back squat performed with maximal concentric effort. Ten strength-trained men (26.1 ± 3.0 y, 1.81 ± 0.07 m, 82.0 ± 10.6 kg) performed three 1-repetition-maximum (1RM) trials on 3 separate days, encompassing lifts performed at 6 relative intensities including 20%, 40%, 60%, 80%, 90%, and 100% of 1RM. Each repetition was simultaneously recorded by a PUSH band and commercial linear position transducer (LPT) (GymAware [GYM]) and compared with measurements collected by a laboratory-based testing device consisting of 4 LPTs and a force plate. Trials 2 and 3 were used for validity analyses. Combining all 120 repetitions indicated that the GYM was highly valid for assessing all criterion variables while the PUSH was only highly valid for estimations of PF (r = .94, CV = 5.4%, ES = 0.28, SEE = 135.5 N). At each relative intensity, the GYM was highly valid for assessing all criterion variables except for PP at 20% (ES = 0.81) and 40% (ES = 0.67) of 1RM. Moreover, the PUSH was only able to accurately estimate PF across all relative intensities (r = .92-.98, CV = 4.0-8.3%, ES = 0.04-0.26, SEE = 79.8-213.1 N). PUSH accuracy for determining MV, PV, MF, MP, and PP across all 6 relative intensities was questionable for the back squat, yet the GYM was highly valid at assessing all criterion variables, with some caution given to estimations of MP and PP performed at lighter loads.

  1. Relationship between strength, power, speed, and change of direction performance of female softball players.

    PubMed

    Nimphius, Sophia; McGuigan, Michael R; Newton, Robert U

    2010-04-01

    The purpose of this study was to investigate (a) the cross-sectional relationship of strength, power, and performance variables in trained female athletes and (b) determine if the relationship between these variables changes over the course of a season. Ten female softball players (age = 18.1 +/- 1.6 years, height = 166.5 +/- 8.9 cm, and weight = 72.4 +/- 10.8 kg) from a state Australian Institute of Sport softball team were tested for maximal lower body strength (one repetition maximum [1RM]), peak force (PF), peak velocity (PV), and peak power (PP) during jump squats unloaded and loaded, unloaded countermovement vertical jump height (VJH) 1 base and 2 base sprint performance and change of direction performance on dominant and nondominant sides. The testing sessions occurred pre, mid, and post a 20-week training period. Relationship between body weight (BW), relative strength (1RM/BW), VJH, relative PP, relative PF, PV, speed, and change of direction variables were assessed by Pearson product-moment correlation coefficient at each testing session. Significant relationships were found across all time points with BW, speed, and change of direction measures (r = 0.70-0.93) and relative strength and measures of speed and change of direction ability (r = -0.73-0.85). There were no significant relationships between VJH and any measure of performance at any time point. In conclusion, BW and relative strength have strong to very strong correlations with speed and change of direction ability, and these correlations remain consistent over the course of the season. However, it seems as if many relationships vary with time, and their relationships should therefore be investigated longitudinally to better determine if these cross-sectional relationships truly reflect a deterministic relationship.

  2. The effect of heavy- vs. light-load jump squats on the development of strength, power, and speed.

    PubMed

    McBride, Jeffrey M; Triplett-McBride, Travis; Davie, Allan; Newton, Robert U

    2002-02-01

    The purpose of this investigation was to examine the effect of an 8-week training program with heavy- vs. light-load jump squats on various physical performance measures and electromyography (EMG). Twenty-six athletic men with varying levels of resistance training experience performed sessions of jump squats with either 30% (JS30, n = 9) or 80% (JS80, n = 10) of their one repetition maximum in the squat (1RM) or served as a control (C, n = 7). An agility test, 20-m sprint, and jump squats with 30% (30J), 55% (55J), and 80% (80J) of their 1RM were performed before and after training. Peak force, peak velocity (PV), peak power (PP), jump height, and average EMG (concentric phase) were calculated for the jumps. There were significant increases in PP and PV in the 30J, 55J, and 80J for the JS30 group (p

  3. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    DOT National Transportation Integrated Search

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  4. A preliminary examination of railroad dispatcher workload, stress, and fatigue

    DOT National Transportation Integrated Search

    2001-05-01

    This report presents the methods, findings and recommendations from a field study that examined the sources and levels of railroad dispatcher workload, stress, and fatigue. The study was initiated in response to concerns raised by two Federal Railroa...

  5. Computer-aided dispatch--traffic management center field operational test : Washington State final report

    DOT National Transportation Integrated Search

    2006-05-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...

  6. Analyzing railroad dispatchers' strategies : a cognitive task analysis of a distributed planning task

    DOT National Transportation Integrated Search

    1998-10-11

    This paper describes a preliminary cognitive task analysis (CTA) that is being conducted to examine how experienced train dispatchers manage and schedule trains. The CTA uses ethnographic field observations and structured interview techniques. The ob...

  7. Innovative telecommunications for law enforcement

    NASA Technical Reports Server (NTRS)

    Sohn, R. L.

    1976-01-01

    The operation of computer-aided dispatch, mobile digital communications, and automatic vehicle location systems used in law enforcement is discussed, and characteristics of systems used by different agencies are compared. With reference to computer-aided dispatch systems, the data base components, dispatcher work load, extent of usage, and design trends are surveyed. The capabilities, levels of communication, and traffic load of mobile digital communications systems are examined. Different automatic vehicle location systems are distinguished, and two systems are evaluated. Other aspects of the application of innovative technology to operational command, control, and communications systems for law enforcement agencies are described.

  8. An online dispatcher training simulator function for real-time analysis and training

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vadari, S.V.; Montstream, M.J.; Ross, H.B. Jr.

    1995-11-01

    Today`s power systems have become so complex that it is not easy for the system dispatcher to realistically predict the results of outages. The situation is compounded whenever the power grid is not in its normal configuration due to maintenance switching or equipment failure. The authors feel that the DTS is an excellent tool that can be used to teach the dispatcher how to react under these conditions. In this paper, the authors present an on-line implementation of the DTS which allows the user to initialize the DTS to an EMS disturbance using data that was captured at the timemore » of the disturbance; and place the DTS in a playback mode and go back to specific times in the scenario. The former feature allows the analyst to investigate EMS disturbances and then train the various dispatchers to be able to recognize such disturbances and to recover from them when they occur. The latter feature allows the instructor (with the trainee) to review and re-experience desired portions of the scenario. It is the authors` feeling that these two features will help the EMS operational staff understand their power system better and help their dispatchers in dealing with operational problems associated with the proper running of the system.« less

  9. Characteristics of service requests and service processes of fire and rescue service dispatch centers: analysis of real world data and the underlying probability distributions.

    PubMed

    Krueger, Ute; Schimmelpfeng, Katja

    2013-03-01

    A sufficient staffing level in fire and rescue dispatch centers is crucial for saving lives. Therefore, it is important to estimate the expected workload properly. For this purpose, we analyzed whether a dispatch center can be considered as a call center. Current call center publications very often model call arrivals as a non-homogeneous Poisson process. This bases on the underlying assumption of the caller's independent decision to call or not to call. In case of an emergency, however, there are often calls from more than one person reporting the same incident and thus, these calls are not independent. Therefore, this paper focuses on the dependency of calls in a fire and rescue dispatch center. We analyzed and evaluated several distributions in this setting. Results are illustrated using real-world data collected from a typical German dispatch center in Cottbus ("Leitstelle Lausitz"). We identified the Pólya distribution as being superior to the Poisson distribution in describing the call arrival rate and the Weibull distribution to be more suitable than the exponential distribution for interarrival times and service times. However, the commonly used distributions offer acceptable approximations. This is important for estimating a sufficient staffing level in practice using, e.g., the Erlang-C model.

  10. Ability of the medical priority dispatch system protocol to predict the acuity of "unknown problem" dispatch response levels.

    PubMed

    Clawson, Jeff; Olola, Christopher; Heward, Andy; Patterson, Brett; Scott, Greg

    2008-01-01

    To determine if Medical Priority Dispatch System's (MPDS's) Protocol 32-Unknown Problem interrogation-based differential dispatch coding distinguishes the acuity of patients as found at the scene by responders, when little (if any) clinical information is known. "Unknown problem" situations (i.e., all cases not fitting into any other chief complaint group) constitute 5-8% of all calls to dispatch centers. From the total patient encounters (n=599,107) in the aggregate data of one year (September 2005 to August 2006), we examined 3,947 (0.7%) encounters initially coded as "unknown problem" by the London Ambulance Service Communications Center for the scene presence of cardiac arrest (CA) and paramedic-determined high-acuity (blue-in [BI]/"lights and siren") findings. Odds ratios (ORs) with 95% confidence intervals (95% CIs) and p-values were used to assess the degree of associations between determinant codes and case outcomes (i.e., CA/BI). Statistically significant association between clinical dispatch determinant codes and case outcomes was observed in the "life status questionable" (LSQ; DELTA-1 [D-1]) and the "standing, sitting, moving, or talking" (BRAVO-1 [B-1]) code pair for the CA outcome (OR [95% CI]: 0.11 [0, 0.63], p=0.005) and for the BI outcome (OR [95% CI]: 0.47 [0.28, 0.77], p=0.003). The LSQ and all three code pairs (i.e., B-1; "community alarm notifications" [B-2]; and "unknown status" [B-3]) also demonstrated significant associations both with the CA outcome (OR [95% CI]: 0.43 [0.23, 0.81], p=0.010) and with the BI outcome (OR [95% CI]: 0.74 [0.56, 0.97], p=0.033). All the determinant code levels yielded significant association between BI and CA cases. This dispatch protocol for unknown problems successfully differentiates dispatch coding of low-acuity and non-CA patients only when specific situational information such as the patient's standing, sitting, moving, or talking can be determined during the interrogation process. Also, emergency medical dispatcher (EMD) reliance on caller-volunteered information to identify predefined critical situations does not appear to add to the protocol's ability to differentiate high-acuity and CA patients. LSQ proved to be a better predictor of both CA and BI outcomes, when compared with the BRAVO-level determinant codes within the "unknown problem" chief complaint. The B-3 (completely unknown) determinant code is a better predictor of severe outcomes than nearly all of the clinically similar BRAVO determinant codes in the entire MPDS protocol. Hence, the B-3 coding should be considered-in terms of its predictability for severe outcome-as falling somewhere between a typical DELTA and a typical BRAVO determinant code.

  11. New materials for thermal energy storage in concentrated solar power plants

    NASA Astrophysics Data System (ADS)

    Guerreiro, Luis; Collares-Pereira, Manuel

    2016-05-01

    Solar Thermal Electricity (STE) is an important alternative to PV electricity production, not only because it is getting more cost competitive with the continuous growth in installed capacity, engineering and associated innovations, but also, because of its unique dispatch ability advantage as a result of the already well established 2-tank energy storage using molten salts (MS). In recent years, research has been performed, on direct MS systems, to which features like modularity and combinations with other (solid) thermal storage materials are considered with the goal of achieving lower investment cost. Several alternative materials and systems have been studied. In this research, storage materials were identified with thermo-physical data being presented for different rocks (e.g. quartzite), super concrete, and other appropriate solid materials. Among the new materials being proposed like rocks from old quarries, an interesting option is the incorporation of solid waste material from old mines belonging to the Iberian Pyritic Belt. These are currently handled as byproducts of past mine activity, and can potentially constitute an environmental hazard due to their chemical (metal) content. This paper presents these materials, as part of a broad study to improve the current concept of solar energy storage for STE plants, and additionally presents a potentially valuable solution for environmental protection related to re-use of mining waste.

  12. Bidding strategy for microgrid in day-ahead market based on hybrid stochastic/robust optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Guodong; Xu, Yan; Tomsovic, Kevin

    In this paper, we propose an optimal bidding strategy in the day-ahead market of a microgrid consisting of intermittent distributed generation (DG), storage, dispatchable DG and price responsive loads. The microgrid coordinates the energy consumption or production of its components and trades electricity in both the day-ahead and real-time markets to minimize its operating cost as a single entity. The bidding problem is challenging due to a variety of uncertainties, including power output of intermittent DG, load variation, day-ahead and real-time market prices. A hybrid stochastic/robust optimization model is proposed to minimize the expected net cost, i.e., expected total costmore » of operation minus total benefit of demand. This formulation can be solved by mixed integer linear programming. The uncertain output of intermittent DG and day-ahead market price are modeled via scenarios based on forecast results, while a robust optimization is proposed to limit the unbalanced power in real-time market taking account of the uncertainty of real-time market price. Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, a micro-turbine, a diesel generator, a battery and a responsive load show the advantage of stochastic optimization in addition to robust optimization.« less

  13. Bidding strategy for microgrid in day-ahead market based on hybrid stochastic/robust optimization

    DOE PAGES

    Liu, Guodong; Xu, Yan; Tomsovic, Kevin

    2016-01-01

    In this paper, we propose an optimal bidding strategy in the day-ahead market of a microgrid consisting of intermittent distributed generation (DG), storage, dispatchable DG and price responsive loads. The microgrid coordinates the energy consumption or production of its components and trades electricity in both the day-ahead and real-time markets to minimize its operating cost as a single entity. The bidding problem is challenging due to a variety of uncertainties, including power output of intermittent DG, load variation, day-ahead and real-time market prices. A hybrid stochastic/robust optimization model is proposed to minimize the expected net cost, i.e., expected total costmore » of operation minus total benefit of demand. This formulation can be solved by mixed integer linear programming. The uncertain output of intermittent DG and day-ahead market price are modeled via scenarios based on forecast results, while a robust optimization is proposed to limit the unbalanced power in real-time market taking account of the uncertainty of real-time market price. Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, a micro-turbine, a diesel generator, a battery and a responsive load show the advantage of stochastic optimization in addition to robust optimization.« less

  14. Solar Energy Grid Integration Systems (SEGIS): adding functionality while maintaining reliability and economics

    NASA Astrophysics Data System (ADS)

    Bower, Ward

    2011-09-01

    An overview of the activities and progress made during the US DOE Solar Energy Grid Integration Systems (SEGIS) solicitation, while maintaining reliability and economics is provided. The SEGIS R&D opened pathways for interconnecting PV systems to intelligent utility grids and micro-grids of the future. In addition to new capabilities are "value added" features. The new hardware designs resulted in smaller, less material-intensive products that are being viewed by utilities as enabling dispatchable generation and not just unpredictable negative loads. The technical solutions enable "advanced integrated system" concepts and "smart grid" processes to move forward in a faster and focused manner. The advanced integrated inverters/controllers can now incorporate energy management functionality, intelligent electrical grid support features and a multiplicity of communication technologies. Portals for energy flow and two-way communications have been implemented. SEGIS hardware was developed for the utility grid of today, which was designed for one-way power flow, for intermediate grid scenarios, AND for the grid of tomorrow, which will seamlessly accommodate managed two-way power flows as required by large-scale deployment of solar and other distributed generation. The SEGIS hardware and control developed for today meets existing standards and codes AND provides for future connections to a "smart grid" mode that enables utility control and optimized performance.

  15. Computer-aided dispatch--traffic management center field operational test : state of Utah final report

    DOT National Transportation Integrated Search

    2006-07-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...

  16. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    DOT National Transportation Integrated Search

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  17. Understanding how train dispatchers manage and control trains : results of a cognitive task analysis

    DOT National Transportation Integrated Search

    1999-03-01

    This report documents the results of a preliminary Cognitive Task Analysis (CTA) that examined how experienced train dispatchers manage and : schedule trains in today's environment The objective was to understand the cognitive demands placed on train...

  18. 49 CFR 228.17 - Dispatcher's record of train movements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Section 228.17 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HOURS OF SERVICE OF RAILROAD EMPLOYEES Records and Reporting § 228..., telephone, radio, or any other electrical or mechanical device to dispatch, report, transmit, receive, or...

  19. Do dispatcher instructions facilitate bystander-initiated cardiopulmonary resuscitation and improve outcomes in patients with out-of-hospital cardiac arrest? A comparison of family and non-family bystanders.

    PubMed

    Fujie, Keiko; Nakata, Yoshio; Yasuda, Susumu; Mizutani, Taro; Hashimoto, Koichi

    2014-03-01

    Bystander-initiated cardiopulmonary resuscitation (CPR) has been reported to increase the possibility of survival in patients with out-of-hospital cardiopulmonary arrest (OHCA). We evaluated the effects of CPR instructions by emergency medical dispatchers on the frequency of bystander CPR and outcomes, and whether these effects differed between family and non-family bystanders. We conducted a retrospective cohort study, using Utstein-style records of OHCA taken in a rural area of Japan between January 2004 and December 2009. Of the 559 patients with non-traumatic OHCA witnessed by laypeople, 231 (41.3%) were given bystander CPR. More OHCA patients received resuscitation when the OHCA was witnessed by non-family bystanders than when it was witnessed by family members (61.4% vs. 34.2%). The patients with non-family-witnessed OHCA were more likely to be given conventional CPR (chest compression plus rescue breathing) or defibrillation with an AED than were those with family-witnessed OHCA. Dispatcher instructions significantly increased the provision of bystander CPR regardless of who the witnesses were. Neurologically favorable survival was increased by CPR in non-family-witnessed, but not in family-witnessed, OHCA patients. No difference in survival rate was observed between the cases provided with dispatcher instructions and those not provided with the instructions. Dispatcher instructions increased the frequency of bystander CPR, but did not improve the rate of neurologically favorable survival in patients with witnessed OHCA. Efforts to enhance the frequency and quality of resuscitation, especially by family members, are required for dispatcher-assisted CPR. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Limitations in Prehospital Communication Between Trauma Helicopter, Ambulance Services, and Dispatch Centers.

    PubMed

    Harmsen, Annelieke Maria Karien; Giannakopoulos, Georgios; Franschman, Gaby; Christiaans, Herman; Bloemers, Frank

    2017-04-01

    Prehospital communication with Emergency Medical Services (EMS) is carried out in hectic situations. Proper communication among all medical personal is required to enhance collaboration, to provide the best care and enable shared situational awareness. The objective of this article was to give insight into current Dutch prehospital emergency care communication among all EMS and evaluate the usage of a new physician staffed helicopter EMS (P-HEMS) cancellation model. Trauma-related P-HEMS dispatches between November 1, 2014 and May 31, 2015 for the Lifeliner 1 were included; a random sample of 100 dispatches was generated. Tape recordings on all verbal prehospital communication between the dispatch center, EMS, and P-HEMS were transcribed and analyzed. Qualitative content analysis was performed, using open coding to code key messages. Ninety-two tape recordings were analyzed. The most frequent reason for P-HEMS dispatch was suspicion of brain injury (24%). The cancellation model was followed in 66%, overruled in 9%, and not applicable in 25%. The main reason for not adhering to the model was hemodynamic stability. In 5% of P-HEMS dispatches, a complete ABCD (airway, breathing, circulation, disability) methodology was used for handover, in 9% a complete Situation-Background-Assessment-Recommendation technique, in 2% a complete Mechanism-Injuries-Signs-Treatment method was used. The other handovers were incomplete. Prehospital handover between EMS on-scene and P-HEMS often entails insufficient information. The cancellation model for P-HEMS is frequently used and promotes adequate information transfer. To increase joined decision-making, more patient and situational information needs to be handed over. Standardization of prehospital trauma handovers will facilitate this and improve trauma patient's outcome. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Air ambulance tasking: mechanism of injury, telephone interrogation or ambulance crew assessment?

    PubMed

    Wilmer, Ian; Chalk, Graham; Davies, Gareth Edward; Weaver, Anne Elizabeth; Lockey, David John

    2015-10-01

    The identification of serious injury is critical to the tasking of air ambulances. London's Air Ambulance (LAA) is dispatched by a flight paramedic based on mechanism of injury (MOI), paramedical interrogation of caller (INT) or land ambulance crew request (REQ).This study aimed to demonstrate which of the dispatch methods was most effective (in accuracy and time) in identifying patients with serious injury. A retrospective review of 3 years of data (to December 2010) was undertaken. Appropriate dispatch was defined as the requirement for LAA to escort the patient to hospital or for resuscitation on-scene. Inaccurate dispatch was where LAA was cancelled or left the patient in the care of the land ambulance crew. The χ(2) test was used to calculate p values; with significance adjusted to account for multiple testing. There were 2203 helicopter activations analysed: MOI 18.9% (n=417), INT 62.4% (n=1375) and REQ 18.7% (n=411). Appropriate dispatch rates were MOI 58.7% (245/417), INT 69.7% (959/1375) and REQ 72.2% (297/411). INT and REQ were both significantly more accurate than MOI (p<0.0001). There was no significant difference in accuracy between INT and REQ (p=0.36). Combining MOI and INT remotely identified 80.2% of patients, with an overtriage rate of 32.8%. Mean time to dispatch (in minutes) was MOI 4, INT 8 and REQ 21. Telephone interrogation of the caller by a flight paramedic is as accurate as ground ambulance crew requests, and both are significantly better than MOI in identifying serious injury. Overtriage remains an issue with all methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Pre-recorded instructional audio vs. dispatchers’ conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study

    PubMed Central

    Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey

    2018-01-01

    BACKGROUND: To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. METHODS: It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio (n=57); or (2) verbal dispatcher assistance (n=52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. RESULTS: There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P>0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P<0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min-1) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). CONCLUSION: When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.

  3. Mobile-phone dispatch of laypersons for CPR in out-of-hospital cardiac arrest.

    PubMed

    Ringh, Mattias; Rosenqvist, Mårten; Hollenberg, Jacob; Jonsson, Martin; Fredman, David; Nordberg, Per; Järnbert-Pettersson, Hans; Hasselqvist-Ax, Ingela; Riva, Gabriel; Svensson, Leif

    2015-06-11

    Cardiopulmonary resuscitation (CPR) performed by bystanders is associated with increased survival rates among persons with out-of-hospital cardiac arrest. We investigated whether rates of bystander-initiated CPR could be increased with the use of a mobile-phone positioning system that could instantly locate mobile-phone users and dispatch lay volunteers who were trained in CPR to a patient nearby with out-of-hospital cardiac arrest. We conducted a blinded, randomized, controlled trial in Stockholm from April 2012 through December 2013. A mobile-phone positioning system that was activated when ambulance, fire, and police services were dispatched was used to locate trained volunteers who were within 500 m of patients with out-of-hospital cardiac arrest; volunteers were then dispatched to the patients (the intervention group) or not dispatched to them (the control group). The primary outcome was bystander-initiated CPR before the arrival of ambulance, fire, and police services. A total of 5989 lay volunteers who were trained in CPR were recruited initially, and overall 9828 were recruited during the study. The mobile-phone positioning system was activated in 667 out-of-hospital cardiac arrests: 46% (306 patients) in the intervention group and 54% (361 patients) in the control group. The rate of bystander-initiated CPR was 62% (188 of 305 patients) in the intervention group and 48% (172 of 360 patients) in the control group (absolute difference for intervention vs. control, 14 percentage points; 95% confidence interval, 6 to 21; P<0.001). A mobile-phone positioning system to dispatch lay volunteers who were trained in CPR was associated with significantly increased rates of bystander-initiated CPR among persons with out-of-hospital cardiac arrest. (Funded by the Swedish Heart-Lung Foundation and Stockholm County; ClinicalTrials.gov number, NCT01789554.).

  4. The linguistic and interactional factors impacting recognition and dispatch in emergency calls for out-of-hospital cardiac arrest: a mixed-method linguistic analysis study protocol.

    PubMed

    Riou, Marine; Ball, Stephen; Williams, Teresa A; Whiteside, Austin; O'Halloran, Kay L; Bray, Janet; Perkins, Gavin D; Cameron, Peter; Fatovich, Daniel M; Inoue, Madoka; Bailey, Paul; Brink, Deon; Smith, Karen; Della, Phillip; Finn, Judith

    2017-07-09

    Emergency telephone calls placed by bystanders are crucial to the recognition of out-of-hospital cardiac arrest (OHCA), fast ambulance dispatch and initiation of early basic life support. Clear and efficient communication between caller and call-taker is essential to this time-critical emergency, yet few studies have investigated the impact that linguistic factors may have on the nature of the interaction and the resulting trajectory of the call. This research aims to provide a better understanding of communication factors impacting on the accuracy and timeliness of ambulance dispatch. A dataset of OHCA calls and their corresponding metadata will be analysed from an interdisciplinary perspective, combining linguistic analysis and health services research. The calls will be transcribed and coded for linguistic and interactional variables and then used to answer a series of research questions about the recognition of OHCA and the delivery of basic life-support instructions to bystanders. Linguistic analysis of calls will provide a deeper understanding of the interactional dynamics between caller and call-taker which may affect recognition and dispatch for OHCA. Findings from this research will translate into recommendations for modifications of the protocols for ambulance dispatch and provide directions for further research. The study has been approved by the Curtin University Human Research Ethics Committee (HR128/2013) and the St John Ambulance Western Australia Research Advisory Group. Findings will be published in peer-reviewed journals and communicated to key audiences, including ambulance dispatch professionals. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Neuropharmacology of 3,4-Methylenedioxypyrovalerone (MDPV), Its Metabolites, and Related Analogs

    PubMed Central

    Baumann, Michael H.; Bukhari, Mohammad O.; Lehner, Kurt R.; Anizan, Sebastien; Rice, Kenner C.; Concheiro, Marta; Huestis, Marilyn A.

    2017-01-01

    3,4-Methylenedioxypyrovalerone (MDPV) is a psychoactive component of so-called bath salts products that has caused serious medical consequences in humans. In this chapter, we review the neuropharmacology of MDPV and related analogs, and supplement the discussion with new results from our preclinical experiments. MDPV acts as a potent uptake inhibitor at plasma membrane transporters for dopamine (DAT) and norepinephrine (NET) in nervous tissue. The MDPV formulation in bath salts is a racemic mixture, and the S isomer is much more potent than the R isomer at blocking DAT and producing abuse-related effects. Elevations in brain extracellular dopamine produced by MDPV are likely to underlie its locomotor stimulant and addictive properties. MDPV displays rapid pharmacokinetics when injected into rats (0.5–2.0 mg/kg), with peak plasma concentrations achieved by 10–20 min and declining quickly thereafter. MDPV is metabolized to 3,4-dihydroxypyrovalerone (3,4-catechol-PV) and 4-hydroxy-3-methoxypyrovalerone (4-OH-3-MeO-PV) in vivo, but motor activation produced by the drug is positively correlated with plasma concentrations of parent drug and not its metabolites. 3,4-Catechol-PV is a potent uptake blocker at DAT in vitro but has little activity after administration in vivo. 4-OH-3-MeO-PV is the main MDPV metabolite but is weak at DAT and NET. MDPV analogs, such as α-pyrrolidinovalerophenone (α-PVP), display similar ability to inhibit DAT and increase extracellular dopamine concentrations. Taken together, these findings demonstrate that MDPV and its analogs represent a unique class of transporter inhibitors with a high propensity for abuse and addiction. PMID:27830575

  6. 14 CFR Special Federal Aviation... - Alternative Communications and Dispatching Procedures

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Procedures Federal Special Federal Aviation Regulation 80 Aeronautics and Space FEDERAL AVIATION... No. 80 Special Federal Aviation Regulation 80—Alternative Communications and Dispatching Procedures 1. Applicability. This Special Federal Aviation Regulation applies to each holder of an air carrier or operating...

  7. 14 CFR Special Federal Aviation... - Alternative Communications and Dispatching Procedures

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Procedures Federal Special Federal Aviation Regulation 80 Aeronautics and Space FEDERAL AVIATION... No. 80 Special Federal Aviation Regulation 80—Alternative Communications and Dispatching Procedures 1. Applicability. This Special Federal Aviation Regulation applies to each holder of an air carrier or operating...

  8. 77 FR 64498 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-22

    ... Dispatchable Wind 1, LLC. Description: TEXAS DISPATCHABLE WIND 1, LLC MBR Application to be effective 10/10... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice.../12. Docket Numbers: ER12-2619-001. Applicants: Eligo Energy, LLC. Description: Amendment to...

  9. Emergency Medical Dispatch. National Standard Curriculum. Instructor Guide. Trainee Guide.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This guide contains all instructor materials and requirements for the National Highway Traffic Safety Administration (NHTSA), Emergency Medical Dispatch (EMD) National Standard Curriculum. It includes lesson plans, instructional aids, and tools and supporting information designed to elevate trained and experienced public safety telecommunicators…

  10. Evaluation of transit operations : data applications of Tri-Met's automated bus dispatching system

    DOT National Transportation Integrated Search

    2001-02-01

    This paper presents an analysis of operating performance for Tri-Met, the transit provider for the Portland, Oregon metropolitan area. The analysis draws on data recovered by Tri-Met's automated Bus Dispatching System (BDS) and focuses on two main su...

  11. Highballing with flimsies : working under train orders on the Espee's coast line

    DOT National Transportation Integrated Search

    1990-01-01

    In classic timetable and train-order territory, the study focuses on several dimensions of train : dispatchers' work, viewed through the other end of the telescope, i.e., from the perspective of the : dispatched train crewmembers and others in the fi...

  12. Dispatching demand response transit service maximizing productivity and service quality guidebook : final report, March 2009.

    DOT National Transportation Integrated Search

    2009-03-01

    The ability of transit agencies to staff dispatch effectively and use technology to its full advantage is critical : in responding proactively as service changes occur and in making sound routing decisions. Sound routing : decisions result in improve...

  13. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  14. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  15. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  16. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  17. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  18. Chance-constrained economic dispatch with renewable energy and storage

    DOE PAGES

    Cheng, Jianqiang; Chen, Richard Li-Yang; Najm, Habib N.; ...

    2018-04-19

    Increased penetration of renewables, along with uncertainties associated with them, have transformed how power systems are operated. High levels of uncertainty means that it is not longer possible to guarantee operational feasibility with certainty, instead constraints are required to be satisfied with high probability. We present a chance-constrained economic dispatch model that efficiently integrates energy storage and high renewable penetration to satisfy renewable portfolio requirements. Specifically, it is required that wind energy contributes at least a prespecified ratio of the total demand and that the scheduled wind energy is dispatchable with high probability. We develop an approximated partial sample averagemore » approximation (PSAA) framework to enable efficient solution of large-scale chanceconstrained economic dispatch problems. Computational experiments on the IEEE-24 bus system show that the proposed PSAA approach is more accurate, closer to the prescribed tolerance, and about 100 times faster than sample average approximation. Improved efficiency of our PSAA approach enables solution of WECC-240 system in minutes.« less

  19. Chance-constrained economic dispatch with renewable energy and storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Jianqiang; Chen, Richard Li-Yang; Najm, Habib N.

    Increased penetration of renewables, along with uncertainties associated with them, have transformed how power systems are operated. High levels of uncertainty means that it is not longer possible to guarantee operational feasibility with certainty, instead constraints are required to be satisfied with high probability. We present a chance-constrained economic dispatch model that efficiently integrates energy storage and high renewable penetration to satisfy renewable portfolio requirements. Specifically, it is required that wind energy contributes at least a prespecified ratio of the total demand and that the scheduled wind energy is dispatchable with high probability. We develop an approximated partial sample averagemore » approximation (PSAA) framework to enable efficient solution of large-scale chanceconstrained economic dispatch problems. Computational experiments on the IEEE-24 bus system show that the proposed PSAA approach is more accurate, closer to the prescribed tolerance, and about 100 times faster than sample average approximation. Improved efficiency of our PSAA approach enables solution of WECC-240 system in minutes.« less

  20. Study on optical polishing experiment of zerodur mirror

    NASA Astrophysics Data System (ADS)

    Wang, Huijun; Li, Hang; Wang, Peng; Guo, Wen; Wang, Yonggang; Du, Yan; Dong, Huiwen

    2014-08-01

    A zerodur mirror whose aperture is 900mm is chosen to be the primary mirror of an optical system. The mirror is polished by rapid polishing and precision polishing methods relatively. The final surface figures of the mirror are as follows: the peak-to-valley value (P-V value) is 0.204λ (λ=632.8nm), and the root-mean-square value (RMS value) is 0.016λ, which meet the requirement of the optical system. The results show that the polishing process is feasible.

  1. Instituto Nacional de Electrification, Guatemala Load Dispatch Center and Global Communications Center. Feasibility report (Instituto Nacional de Electrificacion, Guatemala Centro Nacional de Despacho de Carga y Sistema Global de Comunicaciones). Export trade information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-07-01

    The report presents the results of a feasibility study for the National Load Dispatch Center and Global Communications System Project in Guatemala. The project consists of a communication system which will provide Institute Nacional de Electrificacion (INDE) operations personnel direct voice access to all major power system facilities. In addition, a modern computer based load dispatch center has been configured on a secure and reliable basis to provide automatic generation control of all major interconnected generating plants within Guatemala.

  2. Technical assistance for law-enforcement communications: Case study report two

    NASA Technical Reports Server (NTRS)

    Reilly, N. B.; Mustain, J. A.

    1979-01-01

    Two case histories are presented. In one study the feasibility of consolidating dispatch center operations for small agencies is considered. System load measurements were taken and queueing analysis applied to determine numbers of personnel required for each separate agency and for a consolidated dispatch center. Functional requirements were developed and a cost model was designed to compare relative costs of various alternatives including continuation of the present system, consolidation of a manual system, and consolidated computer-aided dispatching. The second case history deals with the consideration of a multi-regional, intrastate radio frequency for improved interregional communications. Sample standards and specifications for radio equipment are provided.

  3. Classification of pregnancy and labor contractions using a graph theory based analysis.

    PubMed

    Nader, N; Hassan, M; Falou, W; Diab, A; Al-Omar, S; Khalil, M; Marque, C

    2015-08-01

    In this paper, we propose a new framework to characterize the electrohysterographic (EHG) signals recorded during pregnancy and labor. The approach is based on the analysis of the propagation of the uterine electrical activity. The processing pipeline includes i) the estimation of the statistical dependencies between the different recorded EHG signals, ii) the characterization of the obtained connectivity matrices using network measures and iii) the use of these measures in clinical application: the classification between pregnancy and labor. Due to its robustness to volume conductor, we used the imaginary part of coherence in order to produce the connectivity matrix which is then transformed into a graph. We evaluate the performance of several graph measures. We also compare the results with the parameter mostly used in the literature: the peak frequency combined with the propagation velocity (PV +PF). Our results show that the use of the network measures is a promising tool to classify labor and pregnancy contractions with a small superiority of the graph strength over PV+PF.

  4. View southeast of computer controlled energy monitoring system. System replaced ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southeast of computer controlled energy monitoring system. System replaced strip chart recorders and other instruments under the direct observation of the load dispatcher. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  5. Flexible Energy Scheduling Tool for Integrating Variable Generation | Grid

    Science.gov Websites

    , security-constrained economic dispatch, and automatic generation control programs. DOWNLOAD PAPER Electric commitment, security-constrained economic dispatch, and automatic generation control sub-models. Each sub resolutions and operating strategies can be explored. FESTIV produces not only economic metrics but also

  6. Outcome of patients identified as dead (beyond resuscitation) at the point of the emergency call.

    PubMed

    Harvey, L; Woollard, M

    2004-05-01

    Currently, an emergency ambulance is dispatched to all cardiac arrest victims. This study aimed to determine the outcome of patients with a dispatch code of 09B01 ("obvious death") and considers the appropriateness of dispatching a non-emergency response. Dispatch records, patient report forms, and hospital records were reviewed to determine patient outcome. Within the one year study period 141 emergency calls were coded as 09B01. Records were obtained for 59 of these cases (42%). Ambulance crews diagnosed 54 as beyond resuscitation (91.5%, 95% CI 79.5% to 96.2%). Three received resuscitation attempts (5.1%, 95% CI 1.1% to 14.2%): two were subsequently pronounced dead at scene and one on arrival at hospital. Two patients were not in cardiac arrest (3.4%, 95% CI 0.4% to 11.7%): one was a transiently unconscious assault victim, and one had a hand injury after a road accident. Three patients coded as 09B01 were transported to hospital for treatment other than confirmation of death (5.1%, 95% CI 1.1% to 14.2%). Not all patients coded 09B01 by dispatchers are assessed as "dead beyond resuscitation" by attending ambulance crews. Although poor data recovery and a small sample size limited the study, its findings suggest that it is inappropriate to allocate a non-emergency response to 09B01 (obvious death) calls.

  7. Home Care Providers to the Rescue: A Novel First-Responder Programme

    PubMed Central

    Hansen, Steen M.; Brøndum, Stig; Thomas, Grethe; Rasmussen, Susanne R.; Kvist, Birgitte; Christensen, Anette; Lyng, Charlotte; Lindberg, Jan; Lauritsen, Torsten L. B.; Lippert, Freddy K.; Torp-Pedersen, Christian; Hansen, Poul A.

    2015-01-01

    Aim To describe the implementation of a novel first-responder programme in which home care providers equipped with automated external defibrillators (AEDs) were dispatched in parallel with existing emergency medical services in the event of a suspected out-of-hospital cardiac arrest (OHCA). Methods We evaluated a one-year prospective study that trained home care providers in performing cardiopulmonary resuscitation (CPR) and using an AED in cases of suspected OHCA. Data were collected from cardiac arrest case files, case files from each provider dispatch and a survey among dispatched providers. The study was conducted in a rural district in Denmark. Results Home care providers were dispatched to 28 of the 60 OHCAs that occurred in the study period. In ten cases the providers arrived before the ambulance service and subsequently performed CPR. AED analysis was executed in three cases and shock was delivered in one case. For 26 of the 28 cases, the cardiac arrest occurred in a private home. Ninety-five per cent of the providers who had been dispatched to a cardiac arrest reported feeling prepared for managing the initial resuscitation, including use of AED. Conclusion Home care providers are suited to act as first-responders in predominantly rural and residential districts. Future follow-up will allow further evaluation of home care provider arrivals and patient survival. PMID:26509532

  8. Why do electricity policy and competitive markets fail to use advanced PV systems to improve distribution power quality?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McHenry, Mark P.; Johnson, Jay; Hightower, Mike

    The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the networkmore » characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. As a result, we discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.« less

  9. Why do electricity policy and competitive markets fail to use advanced PV systems to improve distribution power quality?

    DOE PAGES

    McHenry, Mark P.; Johnson, Jay; Hightower, Mike

    2016-01-01

    The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the networkmore » characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. As a result, we discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.« less

  10. Random Forest-Based Approach for Maximum Power Point Tracking of Photovoltaic Systems Operating under Actual Environmental Conditions.

    PubMed

    Shareef, Hussain; Mutlag, Ammar Hussein; Mohamed, Azah

    2017-01-01

    Many maximum power point tracking (MPPT) algorithms have been developed in recent years to maximize the produced PV energy. These algorithms are not sufficiently robust because of fast-changing environmental conditions, efficiency, accuracy at steady-state value, and dynamics of the tracking algorithm. Thus, this paper proposes a new random forest (RF) model to improve MPPT performance. The RF model has the ability to capture the nonlinear association of patterns between predictors, such as irradiance and temperature, to determine accurate maximum power point. A RF-based tracker is designed for 25 SolarTIFSTF-120P6 PV modules, with the capacity of 3 kW peak using two high-speed sensors. For this purpose, a complete PV system is modeled using 300,000 data samples and simulated using the MATLAB/SIMULINK package. The proposed RF-based MPPT is then tested under actual environmental conditions for 24 days to validate the accuracy and dynamic response. The response of the RF-based MPPT model is also compared with that of the artificial neural network and adaptive neurofuzzy inference system algorithms for further validation. The results show that the proposed MPPT technique gives significant improvement compared with that of other techniques. In addition, the RF model passes the Bland-Altman test, with more than 95 percent acceptability.

  11. Random Forest-Based Approach for Maximum Power Point Tracking of Photovoltaic Systems Operating under Actual Environmental Conditions

    PubMed Central

    Shareef, Hussain; Mohamed, Azah

    2017-01-01

    Many maximum power point tracking (MPPT) algorithms have been developed in recent years to maximize the produced PV energy. These algorithms are not sufficiently robust because of fast-changing environmental conditions, efficiency, accuracy at steady-state value, and dynamics of the tracking algorithm. Thus, this paper proposes a new random forest (RF) model to improve MPPT performance. The RF model has the ability to capture the nonlinear association of patterns between predictors, such as irradiance and temperature, to determine accurate maximum power point. A RF-based tracker is designed for 25 SolarTIFSTF-120P6 PV modules, with the capacity of 3 kW peak using two high-speed sensors. For this purpose, a complete PV system is modeled using 300,000 data samples and simulated using the MATLAB/SIMULINK package. The proposed RF-based MPPT is then tested under actual environmental conditions for 24 days to validate the accuracy and dynamic response. The response of the RF-based MPPT model is also compared with that of the artificial neural network and adaptive neurofuzzy inference system algorithms for further validation. The results show that the proposed MPPT technique gives significant improvement compared with that of other techniques. In addition, the RF model passes the Bland–Altman test, with more than 95 percent acceptability. PMID:28702051

  12. Training Program for Emergency Medical Technician: Dispatcher. 2--Instructor Lesson Plans.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Intended to assist instructors who wish to conduct a training course for emergency medical technicians (EMTs) serving as dispatchers, this document contains detailed lesson plans organized to structure course presentations. Each lesson plan includes the following elements: unit objectives; suggestions for adapting the lessons to local policies and…

  13. 40 CFR 72.92 - Phase I unit allowance surrender.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... chapter) for all Phase I units in the dispatch system. (iii) Calculating percentage change in dispatch... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Phase I unit allowance surrender. 72... (CONTINUED) PERMITS REGULATION Compliance Certification § 72.92 Phase I unit allowance surrender. (a) Annual...

  14. 40 CFR 72.92 - Phase I unit allowance surrender.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... chapter) for all Phase I units in the dispatch system. (iii) Calculating percentage change in dispatch... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Phase I unit allowance surrender. 72... (CONTINUED) PERMITS REGULATION Compliance Certification § 72.92 Phase I unit allowance surrender. (a) Annual...

  15. 45 CFR 2105.3 - Action on initial requests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... sound grounds. (b) Determination will be dispatched within ten days, excluding Saturdays, Sundays, and... initial determination on requests may be delayed up to a total of ten additional days, excluding Saturdays, Sundays, and legal public holidays and notice of such delay shall be dispatched within the first ten days...

  16. 77 FR 64500 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-22

    ...-000. Applicants: Texas Dispatchable Wind 1, LLC. Description: Self-Certification of Texas Dispatchable Wind 1, LLC. Filed Date: 10/11/12. Accession Number: 20121011-5210. Comments Due: 5 p.m. ET 11/1/12... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice...

  17. 49 CFR 241.11 - Prohibition against conducting a railroad operation dispatched by an extraterritorial dispatcher...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... opportunity to file a waiver request pursuant to § 241.7. (c) Emergencies. (1) In an emergency situation, a... mail. (3) A list of the States that make up the FRA regions and the street and e-mail addresses and fax...

  18. 14 CFR 121.605 - Airplane equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Airplane equipment. 121.605 Section 121.605..., FLAG, AND SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.605 Airplane equipment. No person may dispatch or release an airplane unless it is airworthy and is equipped as prescribed in § 121...

  19. 14 CFR 121.605 - Airplane equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Airplane equipment. 121.605 Section 121.605..., FLAG, AND SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.605 Airplane equipment. No person may dispatch or release an airplane unless it is airworthy and is equipped as prescribed in § 121...

  20. 14 CFR 121.605 - Airplane equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Airplane equipment. 121.605 Section 121.605..., FLAG, AND SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.605 Airplane equipment. No person may dispatch or release an airplane unless it is airworthy and is equipped as prescribed in § 121...

  1. 14 CFR 121.605 - Airplane equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Airplane equipment. 121.605 Section 121.605..., FLAG, AND SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.605 Airplane equipment. No person may dispatch or release an airplane unless it is airworthy and is equipped as prescribed in § 121...

  2. 14 CFR 121.605 - Airplane equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane equipment. 121.605 Section 121.605..., FLAG, AND SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.605 Airplane equipment. No person may dispatch or release an airplane unless it is airworthy and is equipped as prescribed in § 121...

  3. 78 FR 63172 - Commission Information Collection Activities (FERC-733); Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... Electric Reliability Corporation (NERC) and EIA, to fielding and collecting data using a FERC designed... Commission in time to complete the 2014 report to Congress. NERC, as the Electric Reliability Organization... dispatchable and non-dispatchable resources that it needs to conduct its reliability work. Reporting demand...

  4. MIT - Massachusetts Institute of Technology

    Science.gov Websites

    energy cancer diversity global industry public service Solve The MIT Campaign for a Better World give to produce electricity Drug-carrying nanoparticles could help fight brain cancer Drug-carrying nanoparticles could help fight brain cancer New dispatching approach optimizes a city's taxi fleet New dispatching

  5. 14 CFR 121.611 - Dispatch or flight release under VFR.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Dispatch or flight release under VFR. 121.611 Section 121.611 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... operation unless the ceiling and visibility en route, as indicated by available weather reports or forecasts...

  6. 14 CFR 121.611 - Dispatch or flight release under VFR.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Dispatch or flight release under VFR. 121.611 Section 121.611 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... operation unless the ceiling and visibility en route, as indicated by available weather reports or forecasts...

  7. 14 CFR 121.611 - Dispatch or flight release under VFR.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Dispatch or flight release under VFR. 121.611 Section 121.611 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... operation unless the ceiling and visibility en route, as indicated by available weather reports or forecasts...

  8. 14 CFR 121.611 - Dispatch or flight release under VFR.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Dispatch or flight release under VFR. 121.611 Section 121.611 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... operation unless the ceiling and visibility en route, as indicated by available weather reports or forecasts...

  9. 14 CFR 121.611 - Dispatch or flight release under VFR.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Dispatch or flight release under VFR. 121.611 Section 121.611 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... operation unless the ceiling and visibility en route, as indicated by available weather reports or forecasts...

  10. 14 CFR 121.99 - Communications facilities-domestic and flag operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... communication approved by the FAA certificate holding district office, is available over the entire route. The... communications under normal operating conditions between each airplane and the appropriate dispatch office, and... dispatch office must be independent of any system operated by the United States. (c) Each certificate...

  11. 14 CFR 121.99 - Communications facilities-domestic and flag operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... communication approved by the FAA certificate holding district office, is available over the entire route. The... communications under normal operating conditions between each airplane and the appropriate dispatch office, and... dispatch office must be independent of any system operated by the United States. (c) Each certificate...

  12. Fire resistant PV shingle assembly

    DOEpatents

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  13. A simplified controller and detailed dynamics of constant off-time peak current control

    NASA Astrophysics Data System (ADS)

    Van den Bossche, Alex; Dimitrova, Ekaterina; Valchev, Vencislav; Feradov, Firgan

    2017-09-01

    A fast and reliable current control is often the base of power electronic converters. The traditional constant frequency peak control is unstable above 50 % duty ratio. In contrast, the constant off-time peak current control (COTCC) is unconditionally stable and fast, so it is worth analyzing it. Another feature of the COTCC is that one can combine a current control together with a current protection. The time dynamics show a zero-transient response, even when the inductor changes in a wide range. It can also be modeled as a special transfer function for all frequencies. The article shows also that it can be implemented in a simple analog circuit using a wide temperature range IC, such as the LM2903, which is compatible with PV conversion and automotive temperature range. Experiments are done using a 3 kW step-up converter. A drawback is still that the principle does not easily fit in usual digital controllers up to now.

  14. Development of a dynamic traffic assignment and simulation model for incident and emergency management applications in the Birmingham region : aim 3, emergency dispatchers' survey.

    DOT National Transportation Integrated Search

    2010-09-01

    Traffic congestion is a primary concern during major incident and evacuation scenarios and can create difficulties for emergency vehicles attempting to enter and exit affected areas; however, many of the dispatchers who would be responsible for direc...

  15. Airline Transport Pilot, Aircraft Dispatcher, and Flight Navigator. Question Book. Expires September 1, 1991.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC.

    This question book was developed by the Federal Aviation Administration (FAA) for testing applicants who are preparing for certification as airline transport pilots, aircraft dispatchers, or flight navigators. The publication contains several innovative features that are a departure from previous FAA publications related to air carrier personnel…

  16. Dispatch No. 107 of 7 August 1989.

    PubMed

    1989-01-01

    This Order prohibits the cutting, exploitation, and deforestation of "Pino Laso (Decussocarpus rospigliosii)" and other species of the family Podocarpaceae on all public and private property in Venezuela, except in limited and controlled circumstances. The preamble to the Dispatch states that trees of this species help to protect the sources of most of the country's water.

  17. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of an...

  18. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of an...

  19. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of an...

  20. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of an...

  1. 40 CFR 72.33 - Identification of dispatch system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) PERMITS REGULATION Acid Rain Permit Applications § 72.33 Identification of dispatch system. (a... approval of the petition, all provisions of the Acid Rain Program applicable to an affected source or an... provision of the Acid Rain Program and shall not change the liability of the owners and operators of an...

  2. 14 CFR 121.615 - Dispatch or flight release over water: Flag and supplemental operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Dispatch or flight release over water: Flag and supplemental operations. 121.615 Section 121.615 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS OPERATING...

  3. Distributed problem solving by pilots and dispatchers

    NASA Technical Reports Server (NTRS)

    Orasanu, Judith; Wich, Mike; Fischer, Ute; Jobe, Kim; Mccoy, Elaine; Beatty, Roger; Smith, Phil

    1993-01-01

    The study addressed the following question: Are flight planning problems solved differently by PILOTS and DISPATCHERS when they work alone versus when they work together? Aspect of their performance that were of interest include the following: Problem perception and definition; Problem solving strategies and information use; Options considered; Solution and rational; and errors.

  4. 14 CFR 121.613 - Dispatch or flight release under IFR or over the top.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Dispatch or flight release under IFR or over the top. 121.613 Section 121.613 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... appropriate weather reports or forecasts, or any combination thereof, indicate that the weather conditions...

  5. 14 CFR 121.613 - Dispatch or flight release under IFR or over the top.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Dispatch or flight release under IFR or over the top. 121.613 Section 121.613 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... appropriate weather reports or forecasts, or any combination thereof, indicate that the weather conditions...

  6. 14 CFR 121.613 - Dispatch or flight release under IFR or over the top.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Dispatch or flight release under IFR or over the top. 121.613 Section 121.613 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... appropriate weather reports or forecasts, or any combination thereof, indicate that the weather conditions...

  7. 14 CFR 121.613 - Dispatch or flight release under IFR or over the top.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Dispatch or flight release under IFR or over the top. 121.613 Section 121.613 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... appropriate weather reports or forecasts, or any combination thereof, indicate that the weather conditions...

  8. 14 CFR 121.613 - Dispatch or flight release under IFR or over the top.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Dispatch or flight release under IFR or over the top. 121.613 Section 121.613 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... appropriate weather reports or forecasts, or any combination thereof, indicate that the weather conditions...

  9. 46 CFR 401.710 - Operating requirements for holders of Certificates of Authorization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of America and the Minister of Transport of Canada”, effective July 7, 1970, as amended; (c) Provide continuous arrangements and facilities for the efficient dispatching of pilotage service on a first-come, first-serve basis to vessels that give notice of pilotage service requirements to the pilotage dispatch...

  10. The Australian electricity market's pre-dispatch process: Some observations on its efficiency using ordered probit model

    NASA Astrophysics Data System (ADS)

    Zainudin, Wan Nur Rahini Aznie; Becker, Ralf; Clements, Adam

    2015-12-01

    Many market participants in Australia Electricity Market had cast doubts on whether the pre-dispatch process in the electricity market is able to give them good and timely quantity and price information. In a study by [11], they observed a significant bias (mainly indicating that the pre-dispatch process tends to underestimate spot price outcomes), a seasonality features of the bias across seasons and/or trading periods and changes in bias across the years in our sample period (1999 to 2007). In a formal setting of an ordered probit model we establish that there are some exogenous variables that are able to explain increased probabilities of over- or under-predictions of the spot price. It transpires that meteorological data, expected pre-dispatch prices and information on past over- and under-predictions contribute significantly to explaining variation in the probabilities for over- and under-predictions. The results allow us to conjecture that some of the bids and re-bids provided by electricity generators are not made in good faith.

  11. A Real-Time Greedy-Index Dispatching Policy for using PEVs to Provide Frequency Regulation Service

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ke, Xinda; Wu, Di; Lu, Ning

    This article presents a real-time greedy-index dispatching policy (GIDP) for using plug-in electric vehicles (PEVs) to provide frequency regulation services. A new service cost allocation mechanism is proposed to award PEVs based on the amount of service they provided, while considering compensations for delayed-charging and reduction of battery lifetime due to participation of the service. The GIDP transforms the optimal dispatch problem from a high-dimensional space into a one-dimensional space while preserving the solution optimality. When solving the transformed problem in real-time, the global optimality of the GIDP solution can be guaranteed by mathematically proved “indexability”. Because the GIDP indexmore » can be calculated upon the PEV’s arrival and used for the entire decision making process till its departure, the computational burden is minimized and the complexity of the aggregator dispatch process is significantly reduced. Finally, simulation results are used to evaluate the proposed GIDP, and to demonstrate the potential profitability from providing frequency regulation service by using PEVs.« less

  12. Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Baohua; Hu, Weihao; Hou, Peng

    This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less

  13. Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm

    DOE PAGES

    Zhang, Baohua; Hu, Weihao; Hou, Peng; ...

    2017-06-27

    This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less

  14. A Real-Time Greedy-Index Dispatching Policy for using PEVs to Provide Frequency Regulation Service

    DOE PAGES

    Ke, Xinda; Wu, Di; Lu, Ning

    2017-09-18

    This article presents a real-time greedy-index dispatching policy (GIDP) for using plug-in electric vehicles (PEVs) to provide frequency regulation services. A new service cost allocation mechanism is proposed to award PEVs based on the amount of service they provided, while considering compensations for delayed-charging and reduction of battery lifetime due to participation of the service. The GIDP transforms the optimal dispatch problem from a high-dimensional space into a one-dimensional space while preserving the solution optimality. When solving the transformed problem in real-time, the global optimality of the GIDP solution can be guaranteed by mathematically proved “indexability”. Because the GIDP indexmore » can be calculated upon the PEV’s arrival and used for the entire decision making process till its departure, the computational burden is minimized and the complexity of the aggregator dispatch process is significantly reduced. Finally, simulation results are used to evaluate the proposed GIDP, and to demonstrate the potential profitability from providing frequency regulation service by using PEVs.« less

  15. On Why It Is Impossible to Prove that the BDX90 Dispatcher Implements a Time-sharing System

    NASA Technical Reports Server (NTRS)

    Boyer, R. S.; Moore, J. S.

    1983-01-01

    The Software Implemented Fault Tolerance SIFT system, is written in PASCAL except for about a page of machine code. The SIFT system implements a small time sharing system in which PASCAL programs for separate application tasks are executed according to a schedule with real time constraints. The PASCAL language has no provision for handling the notion of an interrupt such as the B930 clock interrupt. The PASCAL language also lacks the notion of running a PASCAL subroutine for a given amount of time, suspending it, saving away the suspension, and later activating the suspension. Machine code was used to overcome these inadequacies of PASCAL. Code which handles clock interrupts and suspends processes is called a dispatcher. The time sharing/virtual machine idea is completely destroyed by the reconfiguration task. After termination of the reconfiguration task, the tasks run by the dispatcher have no relation to those run before reconfiguration. It is impossible to view the dispatcher as a time-sharing system implementing virtual BDX930s running concurrently when one process can wipe out the others.

  16. Multicriteria Selection of Optimal Location of TCSC in a Competitive Energy Market

    NASA Astrophysics Data System (ADS)

    Alomoush, Muwaffaq I.

    2010-05-01

    The paper investigates selection of the best location of thyristor-controlled series compensator (TCSC) in a transmission system from many candidate locations in a competitive energy market such that the TCSC causes a net valuable impact on congestion management outcome, transmission utilization, transmission losses, voltage stability, degree of fulfillment of spot market contracts, and system security. The problem is treated as a multicriteria decision-making process such that the candidate locations of TCSC are the alternatives and the conflicting objectives are the outcomes of the dispatch process, which may have different importance weights. The paper proposes some performance indices that the dispatch decision-making entity can use to measure market dispatch outcomes of each alternative. Based on agreed-upon preferences, the measures presented may help the decision maker compare and rank dispatch scenarios to ultimately decide which location is the optimal one. To solve the multicriteria decision, we use the preference ranking organization method for enrichment evaluations (PROMETHEE), which is a multicriteria decision support method that can handle complex conflicting-objective decision-making processes.

  17. Image phase shift invariance based cloud motion displacement vector calculation method for ultra-short-term solar PV power forecasting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Fei; Zhen, Zhao; Liu, Chun

    Irradiance received on the earth's surface is the main factor that affects the output power of solar PV plants, and is chiefly determined by the cloud distribution seen in a ground-based sky image at the corresponding moment in time. It is the foundation for those linear extrapolation-based ultra-short-term solar PV power forecasting approaches to obtain the cloud distribution in future sky images from the accurate calculation of cloud motion displacement vectors (CMDVs) by using historical sky images. Theoretically, the CMDV can be obtained from the coordinate of the peak pulse calculated from a Fourier phase correlation theory (FPCT) method throughmore » the frequency domain information of sky images. The peak pulse is significant and unique only when the cloud deformation between two consecutive sky images is slight enough, which is likely possible for a very short time interval (such as 1?min or shorter) with common changes in the speed of cloud. Sometimes, there will be more than one pulse with similar values when the deformation of the clouds between two consecutive sky images is comparatively obvious under fast changing cloud speeds. This would probably lead to significant errors if the CMDVs were still only obtained from the single coordinate of the peak value pulse. However, the deformation estimation of clouds between two images and its influence on FPCT-based CMDV calculations are terrifically complex and difficult because the motion of clouds is complicated to describe and model. Therefore, to improve the accuracy and reliability under these circumstances in a simple manner, an image-phase-shift-invariance (IPSI) based CMDV calculation method using FPCT is proposed for minute time scale solar power forecasting. First, multiple different CMDVs are calculated from the corresponding consecutive images pairs obtained through different synchronous rotation angles compared to the original images by using the FPCT method. Second, the final CMDV is generated from all of the calculated CMDVs through a centroid iteration strategy based on its density and distance distribution. Third, the influence of different rotation angle resolution on the final CMDV is analyzed as a means of parameter estimation. Simulations under various scenarios including both thick and thin clouds conditions indicated that the proposed IPSI-based CMDV calculation method using FPCT is more accurate and reliable than the original FPCT method, optimal flow (OF) method, and particle image velocimetry (PIV) method.« less

  18. Image phase shift invariance based cloud motion displacement vector calculation method for ultra-short-term solar PV power forecasting

    DOE PAGES

    Wang, Fei; Zhen, Zhao; Liu, Chun; ...

    2017-12-18

    Irradiance received on the earth's surface is the main factor that affects the output power of solar PV plants, and is chiefly determined by the cloud distribution seen in a ground-based sky image at the corresponding moment in time. It is the foundation for those linear extrapolation-based ultra-short-term solar PV power forecasting approaches to obtain the cloud distribution in future sky images from the accurate calculation of cloud motion displacement vectors (CMDVs) by using historical sky images. Theoretically, the CMDV can be obtained from the coordinate of the peak pulse calculated from a Fourier phase correlation theory (FPCT) method throughmore » the frequency domain information of sky images. The peak pulse is significant and unique only when the cloud deformation between two consecutive sky images is slight enough, which is likely possible for a very short time interval (such as 1?min or shorter) with common changes in the speed of cloud. Sometimes, there will be more than one pulse with similar values when the deformation of the clouds between two consecutive sky images is comparatively obvious under fast changing cloud speeds. This would probably lead to significant errors if the CMDVs were still only obtained from the single coordinate of the peak value pulse. However, the deformation estimation of clouds between two images and its influence on FPCT-based CMDV calculations are terrifically complex and difficult because the motion of clouds is complicated to describe and model. Therefore, to improve the accuracy and reliability under these circumstances in a simple manner, an image-phase-shift-invariance (IPSI) based CMDV calculation method using FPCT is proposed for minute time scale solar power forecasting. First, multiple different CMDVs are calculated from the corresponding consecutive images pairs obtained through different synchronous rotation angles compared to the original images by using the FPCT method. Second, the final CMDV is generated from all of the calculated CMDVs through a centroid iteration strategy based on its density and distance distribution. Third, the influence of different rotation angle resolution on the final CMDV is analyzed as a means of parameter estimation. Simulations under various scenarios including both thick and thin clouds conditions indicated that the proposed IPSI-based CMDV calculation method using FPCT is more accurate and reliable than the original FPCT method, optimal flow (OF) method, and particle image velocimetry (PIV) method.« less

  19. Exercise thermoregulation in men after 1 and 24-hours of 6 degrees head-down tilt

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Weidhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    2000-01-01

    BACKGROUND: Exercise thermoregulation is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise. HYPOTHESIS: We hypothesized that 24 h of head down tilt (HDT24) would alter thermoregulatory responses to a submaximal exercise test and result in a higher exercise rectal temperature (Tre) when compared with exercise Tre after 1 h of head down tilt (HDT1). METHODS: Seven men (31+/-SD 6 yr, peak oxygen uptake (VpO2peak) of 44+/-6 ml x kg(-1) x min(-1)) were studied during 70 min of supine cycling at 58+/-SE 1.5% VO2peak at 22.0 degrees C Tdb and 47% rh. RESULTS: Relative to pre-tilt sitting chair rest data, HDT1 resulted in a 6.1+/-0.9% increase and HDT24 in a 4.3+/-2.3% decrease in PV (delta = 10.4% between experiments, p<0.05) while plasma osmolality remained unchanged (NS). Pre-exercise Tre was elevated after HDT24 (36.71 degrees C +/-0.06 HDT1 vs. 36.93 degrees C+/-0.11 HDT24, p<0.05). The 70 min of exercise did not alter this relationship (p<0.05) with respective end exercise increases in Tre to 38.01 degrees C and 38.26 degrees C (degrees = 1.30 degrees C (HDT1) and 1.33 degrees C (HDT24)). While there were no pre-exercise differences in mean skin temperature (Tsk), a significant (p<0.05) time x treatment interaction occurred during exercise: after min 30 in HDT24 the Tsk leveled off at 31.1 degrees C, while it continued to increase reaching 31.5 degrees C at min 70 in HDT1. A similar response (NS) occurred in skin blood velocity. Neither local sweating rates nor changes in body weight during exercise of -1.63+/-0.24 kg (HDT1) or - 1.33+/-0.09 kg (HDT24) were different (NS) between experiments. CONCLUSION: While HDT24 resulted in elevated pre-exercise Tre, reduced PV, attenuation of Tsk and skin blood velocity during exercise, the absolute increase in exercise Tre was not altered. But if sweat rate and cutaneous vascular responses were similar at different core temperatures (unchanged thermoregulation), the Tre offset could have been caused by the HDT-induced hypovolemia.

  20. Bystander capability to activate speaker function for continuous dispatcher assisted CPR in case of suspected cardiac arrest.

    PubMed

    Steensberg, Alvilda T; Eriksen, Mette M; Andersen, Lars B; Hendriksen, Ole M; Larsen, Heinrich D; Laier, Gunnar H; Thougaard, Thomas

    2017-06-01

    The European Resuscitation Council Guidelines 2015 recommend bystanders to activate their mobile phone speaker function, if possible, in case of suspected cardiac arrest. This is to facilitate continuous dialogue with the dispatcher including (if required) cardiopulmonary resuscitation instructions. The aim of this study was to measure the bystander capability to activate speaker function in case of suspected cardiac arrest. In 87days, a systematic prospective registration of bystander capability to activate the speaker function, when cardiac arrest was suspected, was performed. For those asked, "can you activate your mobile phone's speaker function", audio recordings were examined and categorized into groups according to the bystanders capability to activate speaker function on their own initiative, without instructions, or with instructions from the emergency medical dispatcher. Time delay was measured, in seconds, for the bystanders without pre-activated speaker function. 42.0% (58) was able to activate the speaker function without instructions, 2.9% (4) with instructions, 18.1% (25) on own initiative and 37.0% (51) were unable to activate the speaker function. The median time to activate speaker function was 19s and 8s, with and without instructions, respectively. Dispatcher assisted cardiopulmonary resuscitation with activated speaker function, in cases of suspected cardiac arrest, allows for continuous dialogue between the emergency medical dispatcher and the bystander. In this study, we found a 63.0% success rate of activating the speaker function in such situations. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The survival benefit of dual dispatch of EMS and fire-fighters in out-of-hospital cardiac arrest may differ depending on population density--a prospective cohort study.

    PubMed

    Nordberg, Per; Jonsson, Martin; Forsberg, Sune; Ringh, Mattias; Fredman, David; Riva, Gabriel; Hasselqvist-Ax, Ingela; Hollenberg, Jacob

    2015-05-01

    Outcome after out-of-hospital cardiac arrest (OHCA) varies between contexts. Dual dispatching of fire-fighters or police in addition to emergency medical services (EMS) has the potential to increase survival, but the effect in urban vs. rural areas is unknown. The aim of this study was to determine the effects of dual dispatching on response times and outcome in regions with different population density. The study design was a prospective cohort study of EMS-treated OHCAs from 2004 (historical controls, only EMS dispatch) and 2006-2009 (intervention, dual dispatch of EMS and fire-fighters), with data on exact geographical coordinates. Patients were divided into four subgroups depending on population density: rural (<250 persons/km2), suburban (250-2999/km2), urban (3000-5999/km2) and downtown (≥6000/km2). Totally, 2513 OHCAs were included (historical controls, n=571 and intervention, n=1942). Median time to arrival of first unit shortened significantly in all subgroups, ranging from 0.8 to 3.2 min, with the main time gain in the rural area. There were significant differences in 30-day survival between the historical controls vs. the intervention group in the suburban population (3.1% vs. 7.0%, p=0.02) and in downtown (4.1 vs. 14.6, p=0.04). In the urban population the difference was 2.7 vs. 6.9% (p=0.06) and in the rural population (4.7 vs. 5.3, p=0.82). Dual dispatch of fire-fighters and EMS in OHCA significantly reduced response times in all studied regions. The 30-day survival increased significantly in the downtown and suburban populations, while a limited impact was seen in the rural areas. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Transmission dispatch and congestion management in open market systems

    NASA Astrophysics Data System (ADS)

    Fang, Risheng

    This thesis is located in the domain of electricity supply industry restructuring. It deals with emerging issues, whose understanding is essential to advancing knowledge of open access transmission theory and proceeds to develop approaches for solving the transmission dispatch and congestion management problem. An overview of current trends and experiences in utility restructuring and the main models for restructuring, as well as the classifications of system operators, is first presented. A fully unbundled competitive electricity market model, called the bilateral/multilateral trades model, is then developed. A survey of current research in transmission dispatch and congestion management is included with discussion of transmission capacity and ancillary services. A methodology for the power dispatch problem in a structure dominated by bilateral and multilateral transmission contracts is presented. Group structures are mathematically formulated and explored and three basic types of curtailment strategies proposed for use by market participants. A more complex model is then developed, which takes into account the co-existence of bilateral and multilateral contracts with pool type dynamic supplies and demands based on bids and market clearing prices. An integrated dispatch strategy to reconcile all three types of transactions (bilateral, multilateral and pool) is then developed. Prioritization of electricity transactions and related curtailment strategies are explored and a mechanism for coordination between market participants to achieve additional economic advantages is described. A theory of security based rescheduling is presented in order to investigate the security-related aspects of operation in an unbundled and deregulated system. The impact of post-contingency corrective capability on optimal rescheduling results has been identified and the advantage of incorporating post-contingency corrective rescheduling into the objective function demonstrated. Finally, integrated congestion management procedures in real-time system operation and in forward energy markets are developed. Market price response and coordination of dispatch by the ISO are incorporated to achieve an overall strategy.

  3. Electricity demand and storage dispatch modeling for buildings and implications for the smartgrid

    NASA Astrophysics Data System (ADS)

    Zheng, Menglian; Meinrenken, Christoph

    2013-04-01

    As an enabler for demand response (DR), electricity storage in buildings has the potential to lower costs and carbon footprint of grid electricity while simultaneously mitigating grid strain and increasing its flexibility to integrate renewables (central or distributed). We present a stochastic model to simulate minute-by-minute electricity demand of buildings and analyze the resulting electricity costs under actual, currently available DR-enabling tariffs in New York State, namely a peak/offpeak tariff charging by consumed energy (monthly total kWh) and a time of use tariff charging by power demand (monthly peak kW). We then introduce a variety of electrical storage options (from flow batteries to flywheels) and determine how DR via temporary storage may increase the overall net present value (NPV) for consumers (comparing the reduced cost of electricity to capital and maintenance costs of the storage). We find that, under the total-energy tariff, only medium-term storage options such as batteries offer positive NPV, and only at the low end of storage costs (optimistic scenario). Under the peak-demand tariff, however, even short-term storage such as flywheels and superconducting magnetic energy offer positive NPV. Therefore, these offer significant economic incentive to enable DR without affecting the consumption habits of buildings' residents. We discuss implications for smartgrid communication and our future work on real-time price tariffs.

  4. Characterization, antioxidant and immunomodulatory activities of polysaccharides from Prunella vulgaris Linn.

    PubMed

    Li, Chao; Huang, Qiang; Fu, Xiong; Yue, Xiu-Jie; Liu, Rui Hai; You, Li-Jun

    2015-04-01

    Water-soluble polysaccharides from Prunella vulgaris Linn (P. vulgaris) were fractionated using DEAE-Sepharose fast-flow column to obtain several eluents of water (PV-P1), 0.1M NaCl (PV-P2) and 0.2M NaCl (PV-P3). Structural analyses showed that PV-P1 had a higher molecular weight and degree of branching as compared to PV-P2 and PV-P3. Tertiary structure analyses indicated that PV-P1, PV-P2 and PV-P3 did not have triple-helical conformation. PV-P2 and PV-P3 showed stronger antioxidant activities than PV-P1, as measured radical scavenging capacities. PV-P1 showed stronger immunomodulatory activities than PV-P2 and PV-P3 in term of stimulation of the production of pro-inflammatory cytokines, including nitric oxide (NO), tumor necrosis factor-α (TNF-α), and interleukin-6 (IL-6) in murine macrophage RAW 264.7 cells. PV-P1, PV-P2 and PV-P3 did not exhibit cytotoxicities against RAW 264.7 at the concentrations tested. These results suggest that P. vulgaris polysaccharides could be explored as potential antioxidant and immunomodulatory agents for the complementary medicine or functional foods. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Coupling of Luminescent Solar Concentrators to Plasmonic Solar Cells

    NASA Astrophysics Data System (ADS)

    Wang, Shu-Yi

    To make inexpensive solar cells is a continuous goal for solar photovoltaic (PV) energy industry. Thin film solar cells of various materials have been developed and continue to emerge in order to replace bulk silicon solar cells. A thin film solar cell not only uses less material but also requires a less expensive refinery process. In addition, other advantages coming along with small thickness are higher open circuit voltage and higher conversion efficiency. However, thin film solar cells, especially those made of silicon, have significant optical losses. In order to address this problem, this thesis investigates the spectral coupling of thin films PV to luminescent solar concentrators (LSC). LSC are passive devices, consisting of plastic sheets embedded with fluorescent dyes which absorb part of the incoming radiation spectrum and emit at specific wavelength. The emitted light is concentrated by total internal reflection to the edge of the sheet, where the PVs are placed. Since the light emitted from the LSC edge is usually in a narrow spectral range, it is possible to employ diverse strategies to enhance PV absorption at the peak of the emission wavelength. Employing plasmonic nanostructures has been shown to enhance absorption of thin films via forward scattering, diffraction and localized surface plasmon. These two strategies are theoretically investigated here for improving the absorption and elevating the output power of a thin film solar cell. First, the idea of spectral coupling of luminescent solar concentrators to plasmonic solar cells is introduced to assess its potential for increasing the power output. This study is carried out employing P3HT/PC60BM organic solar cells and LSC with Lumogen Red dyes. A simplified spectral coupling analysis is employed to predict the power density, considering the output spectrum of the LSC equivalent to the emission spectrum of the dye and neglecting any angular dependence. Plasmonic tuning is conducted to enhance absorption at the emission peak of the dye. A factorial increase in the output power density of coupled PV as compared to PV exposed directly to solar spectrum is observed for high light concentration on the edge. These initial results motivated a more in-depth study of coupled LSC-PV system, which took into account the radiative transport inside the realistic LSC. These investigations were carried out on LSCs using Lumogen Red305 and Rhodamine 6G dyes coupled to pristine and plasmonic ultra-thin film silicon solar cells. Prediction based on detailed balance shows that the coupled LSC-plasmonic solar cell can generate 63.7 mW/cm2 with a photocurrent density of 71.3 mA/cm2 which is higher than that of cSi solar cells available on current market. The second part of the thesis focuses on PV absorption enhancement techniques. First, the effect of vertical positioning of plasmonic nanostructures on absorption enhancement was theoretically investigated to understand which one of the three mechanisms usually responsible for the enhancement (forward scattering, diffraction and localized surface plamson) plays the dominant role. Simulation results suggested that the maximum enhancement occurred when placing the nanostructures in the rear side of the cell because of longer path length due to scattering. The experimental effort then switched focus on substrate patterning, which is a less expensive alternative to plasmonic absorption enhancement. Specifically, a nanostructured substrate was prepared by a simple electrochemical process based on two-step aluminum anodization technique. The absorption of thin film silicon deposited on these substrates showed a broadband enhancement. The overall photocurrent density was up to 40% higher than that of films deposited on flat substrates. In conclusion, the studies carried out in this thesis indicate that spectral coupling of LSCs to thin film solar cells could lead to significant improvements in PV output power density. Moreover, while the absorption of thin film solar cells can be enhanced by plasmonic nanostructures, it is shown that alternative methods, such as direct deposition of the films on inexpensively nanostructured substrates could also be employed to obtain significant enhancements. Combining these strategies may lead to inexpensive solar power harvesting systems with significant economic benefits. These strategies are not material-specific but applicable to a wide range of thin film solar cells.

  6. 49 CFR 234.306 - Multiple dispatching or maintaining railroads with respect to the same highway-rail or pathway...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... respect to the same highway-rail or pathway grade crossing; appointment of responsible railroad. 234.306... Conditions at Highway-Rail and Pathway Grade Crossings § 234.306 Multiple dispatching or maintaining railroads with respect to the same highway-rail or pathway grade crossing; appointment of responsible...

  7. 49 CFR 234.306 - Multiple dispatching or maintaining railroads with respect to the same highway-rail or pathway...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... respect to the same highway-rail or pathway grade crossing; appointment of responsible railroad. 234.306... Conditions at Highway-Rail and Pathway Grade Crossings § 234.306 Multiple dispatching or maintaining railroads with respect to the same highway-rail or pathway grade crossing; appointment of responsible...

  8. 49 CFR 234.306 - Multiple dispatching or maintaining railroads with respect to the same highway-rail or pathway...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... respect to the same highway-rail or pathway grade crossing; appointment of responsible railroad. 234.306... Conditions at Highway-Rail and Pathway Grade Crossings § 234.306 Multiple dispatching or maintaining railroads with respect to the same highway-rail or pathway grade crossing; appointment of responsible...

  9. 17 CFR 240.17Ad-1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... or mails the item to, or the item is awaiting pick-up by, the presentor or a person designated by the... transfer agent dispatches or mails the item to, or the item is awaiting pick-up by, the outside registrar... registrar dispatches or mails the item to, or the item is awaiting pick-up by, the presenting transfer agent...

  10. 17 CFR 240.17Ad-1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... or mails the item to, or the item is awaiting pick-up by, the presentor or a person designated by the... transfer agent dispatches or mails the item to, or the item is awaiting pick-up by, the outside registrar... registrar dispatches or mails the item to, or the item is awaiting pick-up by, the presenting transfer agent...

  11. Model documentation: Electricity Market Module, Electricity Fuel Dispatch Submodule

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This report documents the objectives, analytical approach and development of the National Energy Modeling System Electricity Fuel Dispatch Submodule (EFD), a submodule of the Electricity Market Module (EMM). The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.

  12. Monthly Solar Photovoltaic Module Shipments Report

    EIA Publications

    2017-01-01

    This report contains newly collected monthly summary data beginning in January 2017, for the photovoltaic industry in the United States. The subset of respondents who now must report monthly represents approximately 90% of photovoltaic (PV) activity in the United States, based on prior year’s data. Data include manufacturing, imports, and exports of modules in the United States and its territories. Summary data include volumes in peak kilowatts and average prices. Where possible, imports and exports are listed by country, and shipments to the United States are listed by state.

  13. Economic challenges of hybrid microgrid: An analysis and approaches for rural electrification

    NASA Astrophysics Data System (ADS)

    Habibullah, Mohammad; Mahmud, Khizir; Koçar, Günnur; Islam, A. K. M. Sadrul; Salehin, Sayedus

    2017-06-01

    This paper focuses on the integration of three renewable resources: biogas, wind energy and solar energy, utilizing solar PV panels, a biogas generator, and a wind turbine, respectively, to analyze the technical and economic challenges of a hybrid micro-gird. The integration of these sources has been analyzed and optimized based on realistic data for a real location. Different combinations of these sources have been analyzed to find out the optimized combination based on the efficiency and the minimum cost of electricity (COE). Wind and solar energy are considered as the primary sources of power generation during off-peak hours, and any excess power is used to charge a battery bank. During peak hours, biogas generators produce power to support the additional demand. A business strategy to implement the integrated optimized system in rural areas is discussed.

  14. Measurement of Global Radiation using Photovoltaic Panels

    NASA Astrophysics Data System (ADS)

    Veroustraete, Frank; Bronders, Jan; Lefevre, Filip; Mensink, Clemens

    2014-05-01

    The Vito Unit - Environmental and Spatial Aspects (RMA) - for many of its models makes use of global solar radiation. From this viewpoint and also from the notion that this variable is seldom measured or available at the local scale and at high multi-temporal frequencies, it can be stated that many models are fed with low quality estimates of global solar radiation at the local to regional scales. A project was initiated called SUNSPIDER with the following objective. To make use of photovoltaic solar panels to measure solar radiation at the highest spatio-temporal resolution, from the local to the regional scales and from minutes to years. To integrate the measured solar fields in different application fields like, plant systems and agriculture, agro-meteorology and hydrology and last but not least solar energy applications. In Belgium about 250.000 PV installations have been built leading to about 6% electric power supply from photovoltaics on a yearly basis. Last year in June, the supply reached a peak of more than 20% of the total power input on the Belgian grid. A database of Belgian residential solar panel sites will be compiled. The database will serve as an input to an inverted PV model to be able to perform radiation calculations specifically for each of the validated panel sites based on minutely logged power data. Data acquisition for these sites will start each time a site is validated and hence imported in the database. Keywords: Photovoltaic Panels; PV modelling; Global Radiation.

  15. Noncontact on-machine measurement system based on capacitive displacement sensors for single-point diamond turning

    NASA Astrophysics Data System (ADS)

    Li, Xingchang; Zhang, Zhiyu; Hu, Haifei; Li, Yingjie; Xiong, Ling; Zhang, Xuejun; Yan, Jiwang

    2018-04-01

    On-machine measurements can improve the form accuracy of optical surfaces in single-point diamond turning applications; however, commercially available linear variable differential transformer sensors are inaccurate and can potentially scratch the surface. We present an on-machine measurement system based on capacitive displacement sensors for high-precision optical surfaces. In the proposed system, a position-trigger method of measurement was developed to ensure strict correspondence between the measurement points and the measurement data with no intervening time-delay. In addition, a double-sensor measurement was proposed to reduce the electric signal noise during spindle rotation. Using the proposed system, the repeatability of 80-nm peak-to-valley (PV) and 8-nm root-mean-square (RMS) was achieved through analyzing four successive measurement results. The accuracy of 109-nm PV and 14-nm RMS was obtained by comparing with the interferometer measurement result. An aluminum spherical mirror with a diameter of 300 mm was fabricated, and the resulting measured form error after one compensation cut was decreased to 254 nm in PV and 52 nm in RMS. These results confirm that the measurements of the surface form errors were successfully used to modify the cutting tool path during the compensation cut, thereby ensuring that the diamond turning process was more deterministic. In addition, the results show that the noise level was significantly reduced with the reference sensor even under a high rotational speed.

  16. Thermal Analysis of of Near-Isothermal Compressed Gas Energy Storage System

    DOE PAGES

    Odukomaiya, Adewale; Abu-Heiba, Ahmad; Gluesenkamp, Kyle R.; ...

    2016-01-01

    In this paper, alternative system configurations for a novel Ground-Level Integrated Diverse Energy Storage (GLIDES) system, which can store energy via input of electricity and heat and deliver dispatchable electricity, is presented. The proposed system is low-cost and hybridizes compressed air and pumped hydro storage approaches that will allow for the off-peak storage of intermittent renewable energy for use during peak times. This study reveals that implementing direct-contact low grade heat exchange via sprayed falling droplets to cool the gas during charging (compression) and warm the gas during discharging (expansion) can be achieved through a secondary recirculating loop of liquid.more » This study shows that if the recirculating liquid loop is pre-conditioned with waste-heat prior to spraying during gas expansion and considering all the round trip conversion losses from standard 120 V 60 HZ electricity input and output with utilization of low grade heat at 90 C the alternative system design leads to a 16% boost in round trip efficiency of the electricity storage to elec = 82% with an energy density of ED = 3.59 MJ/m3.« less

  17. Supported PV module assembly

    DOEpatents

    Mascolo, Gianluigi; Taggart, David F.; Botkin, Jonathan D.; Edgett, Christopher S.

    2013-10-15

    A supported PV assembly may include a PV module comprising a PV panel and PV module supports including module supports having a support surface supporting the module, a module registration member engaging the PV module to properly position the PV module on the module support, and a mounting element. In some embodiments the PV module registration members engage only the external surfaces of the PV modules at the corners. In some embodiments the assembly includes a wind deflector with ballast secured to a least one of the PV module supports and the wind deflector. An array of the assemblies can be secured to one another at their corners to prevent horizontal separation of the adjacent corners while permitting the PV modules to flex relative to one another so to permit the array of PV modules to follow a contour of the support surface.

  18. Pressure-equalizing PV assembly and method

    DOEpatents

    Dinwoodie, Thomas L.

    2004-10-26

    Each PV assembly of an array of PV assemblies comprises a base, a PV module and a support assembly securing the PV module to a position overlying the upper surface of the base. Vents are formed through the base. A pressure equalization path extends from the outer surface of the PV module, past the PV module, to and through at least one of the vents, and to the lower surface of the base to help reduce wind uplift forces on the PV assembly. The PV assemblies may be interengaged, such as by interengaging the bases of adjacent PV assemblies. The base may include a main portion and a cover and the bases of adjacent PV assemblies may be interengaged by securing the covers of adjacent bases together.

  19. Performance comparison investigation on solar photovoltaic-thermoelectric generation and solar photovoltaic-thermoelectric cooling hybrid systems under different conditions

    NASA Astrophysics Data System (ADS)

    Wu, Shuang-Ying; Zhang, Yi-Chen; Xiao, Lan; Shen, Zu-Guo

    2018-07-01

    The performance of solar photovoltaic-thermoelectric generation hybrid system (PV-TGS) and solar photovoltaic-thermoelectric cooling hybrid system (PV-TCS) under different conditions were theoretically analysed and compared. To test the practicality of these two hybrid systems, the performance of stand-alone PV system was also studied. The results show that PV-TGS and PV-TCS in most cases will result in the system with a better performance than stand-alone PV system. The advantage of PV-TGS is emphasised in total output power and conversion efficiency which is even poorer in PV-TCS than that in stand-alone PV system at the ambient wind speed uw being below 3 m/s. However, PV-TCS has obvious advantage on lowering the temperature of PV cell. There is an obvious increase in tendency on the performance of PV-TGS and PV-TCS when the cooling capacity of two hybrid systems varies from around 0.06 to 0.3 W/K. And it is also proved that not just a-Si in PV-TGS can produce a better performance than the stand-alone PV system alone at most cases.

  20. Molecular characterization of novel mucosotropic papillomaviruses from a Florida manatee (Trichechus manatus latirostris).

    PubMed

    2015-12-01

    We isolated two new manatee papillomavirus (PV) types, TmPV3 and TmPV4, from a Florida manatee (Trichechus manatus latirostris). Two PV types were previously isolated from this species. TmPV1 is widely dispersed amongst manatees and a close-to-root PV; not much is known about TmPV2. The genomes of TmPV3 and TmPV4 were 7622 and 7771 bp in size, respectively. Both PVs had a genomic organization characteristic of all PVs, with one non-coding region and seven ORFs, including the E7 ORF that is absent in other cetacean PVs. Although these PVs were isolated from separate genital lesions of the same manatee, an enlarged E2/E4 ORF was found only in the TmPV4 genome. The full genome and L1 sequence similarities between TmPV3 and TmPV4 were 63.2 and 70.3 %, respectively. These genomes shared only 49.1 and 50.2 % similarity with TmPV1. The pairwise alignment of L1 nucleotide sequences indicated that the two new PVs nested in a monophyletic group of the genus Rhopapillomavirus, together with the cutaneotropic TmPV1 and TmPV2.

Top