SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gauntt, D
2015-06-15
Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results ofmore » measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kimpe, T; Marchessoux, C; Rostang, J
Purpose: Use of color images in medical imaging has increased significantly the last few years. As of today there is no agreed standard on how color information needs to be visualized on medical color displays, resulting into large variability of color appearance and it making consistency and quality assurance a challenge. This paper presents a proposal for an extension of DICOM GSDF towards color. Methods: Visualization needs for several color modalities (multimodality imaging, nuclear medicine, digital pathology, quantitative imaging applications…) have been studied. On this basis a proposal was made for desired color behavior of color medical display systems andmore » its behavior and effect on color medical images was analyzed. Results: Several medical color modalities could benefit from perceptually linear color visualization for similar reasons as why GSDF was put in place for greyscale medical images. An extension of the GSDF (Greyscale Standard Display Function) to color is proposed: CSDF (color standard display function). CSDF is based on deltaE2000 and offers a perceptually linear color behavior. CSDF uses GSDF as its neutral grey behavior. A comparison between sRGB/GSDF and CSDF confirms that CSDF significantly improves perceptual color linearity. Furthermore, results also indicate that because of the improved perceptual linearity, CSDF has the potential to increase perceived contrast of clinically relevant color features. Conclusion: There is a need for an extension of GSDF towards color visualization in order to guarantee consistency and quality. A first proposal (CSDF) for such extension has been made. Behavior of a CSDF calibrated display has been characterized and compared with sRGB/GSDF behavior. First results indicate that CSDF could have a positive influence on perceived contrast of clinically relevant color features and could offer benefits for quantitative imaging applications. Authors are employees of Barco Healthcare.« less
Development and evaluation of a method of calibrating medical displays based on fixed adaptation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sund, Patrik, E-mail: patrik.sund@vgregion.se; Månsson, Lars Gunnar; Båth, Magnus
2015-04-15
Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrastmore » levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.« less
NASA Astrophysics Data System (ADS)
Chesterman, Frédérique; Manssens, Hannah; Morel, Céline; Serrell, Guillaume; Piepers, Bastian; Kimpe, Tom
2017-03-01
Medical displays for primary diagnosis are calibrated to the DICOM GSDF1 but there is no accepted standard today that describes how display systems for medical modalities involving color should be calibrated. Recently the Color Standard Display Function3,4 (CSDF), a calibration using the CIEDE2000 color difference metric to make a display as perceptually linear as possible has been proposed. In this work we present the results of a first observer study set up to investigate the interpretation accuracy of a rainbow color scale when a medical display is calibrated to CSDF versus DICOM GSDF and a second observer study set up to investigate the detectability of color differences when a medical display is calibrated to CSDF, DICOM GSDF and sRGB. The results of the first study indicate that the error when interpreting a rainbow color scale is lower for CSDF than for DICOM GSDF with statistically significant difference (Mann-Whitney U test) for eight out of twelve observers. The results correspond to what is expected based on CIEDE2000 color differences between consecutive colors along the rainbow color scale for both calibrations. The results of the second study indicate a statistical significant improvement in detecting color differences when a display is calibrated to CSDF compared to DICOM GSDF and a (non-significant) trend indicating improved detection for CSDF compared to sRGB. To our knowledge this is the first work that shows the added value of a perceptual color calibration method (CSDF) in interpreting medical color images using the rainbow color scale. Improved interpretation of the rainbow color scale may be beneficial in the area of quantitative medical imaging (e.g. PET SUV, quantitative MRI and CT and doppler US), where a medical specialist needs to interpret quantitative medical data based on a color scale and/or detect subtle color differences and where improved interpretation accuracy and improved detection of color differences may contribute to a better diagnosis. Our results indicate that for diagnostic applications involving both grayscale and color images, CSDF should be chosen over DICOM GSDF and sRGB as it assures excellent detection for color images and at the same time maintains DICOM GSDF for grayscale images.
Grayscale standard display function on LCD color monitors
NASA Astrophysics Data System (ADS)
De Monte, Denis; Casale, Carlo; Albani, Luigi; Bonfiglio, Silvio
2007-03-01
Currently, as a rule, digital medical systems use monochromatic Liquid Crystal Display (LCD) monitors to ensure an accurate reproduction of the Grayscale Standard Display Function (GSDF) as specified in the Digital Imaging and Communications in Medicine (DICOM) Standard. As a drawback, special panels need to be utilized in digital medical systems, while it would be preferable to use regular color panels, which are manufactured on a wide scale and are thus available at by far lower prices. The method proposed introduces a temporal color dithering technique to accurately reproduce the GSDF on color monitors without losing monitor resolution. By exploiting the characteristics of the Human Visual System (HVS) the technique ensures that a satisfactory grayscale reproduction is achieved minimizing perceivable flickering and undesired color artifacts. The algorithm has been implemented in the monitor using a low-cost Field Programmable Gate Array (FPGA). Quantitative evaluations of luminance response on a 3 Mega-pixel color monitor have shown that the compliance with the GSDF can be achieved with the accuracy level required by medical applications. At the same time the measured color deviation is below the threshold perceivable by the human eye.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenney, S; Bevins, N; Flynn, M
2015-06-15
Purpose: The calibration of monitors in radiology is critical to ensure a standardized reading environment. If left unchecked, monitors initially calibrated to follow the DICOM Grayscale Standard Display Function (GSDF) can fall out of calibration. This work presents a quantitative evaluation of the stability of a cohort of monitors with similar deployment times and clinical utilization. Methods: Fifty-four liquid crystal display (LCD) monitors (NEC L200ME) were deployed for clinical use in 2009. At that time, a subset of eight of these monitors were used to generate a look-up table (LUT) using the open-source software pacsDisplay. The software was used tomore » load the LUT to the graphics card of the computer in order to make the monitors compliant with the GSDF. The luminance response of the monitors was evaluated twice over six years, once in 2011 and again in 2015. Results: As expected, the maximum luminance of the monitors decreased over time, with an average reduction from 2009 of 35% in 2011, and 53% in 2015. The luminance ratio (maximum luminance divided by the minimum) also decreased, with the all of the decrease occurring in the first two years (average 20%). There was an overall increase in relative error compared with the DICOM GSDF from measurement to measurement, indicating that deviation from the GSDF increases with monitor luminance reduction. Along with changes in luminance, several other issues were identified during the testing, including non-uniformities, bad pixels, and missing calibration software. Conclusion: From the initial installation of these monitors, most of the degradation occurred during the first two years, highlighting the importance of routine clinical testing of displays. Following such quality assurance, displays could be either re-calibrated or replaced depending on different thresholds. In addition, other issues not related to luminance could be identified and corrected.« less
The effect of time in use on the display performance of the iPad.
Caffery, Liam J; Manthey, Kenneth L; Sim, Lawrence H
2016-07-01
The aim of this study was to evaluate changes to the luminance, luminance uniformity and conformance to the digital imaging and communication in medicine greyscale standard display function (GSDF) as a function of time in use for the iPad. Luminance measurements of the American Association of Physicists in Medicine (AAPM) Group 18 task group (TG18) luminance uniformity and luminance test patterns (TG18-UNL and TG18-LN8) were performed using a calibrated near-range luminance meter. Nine sets of measurements were taken, where the time in use of the iPad ranged from 0 to 2500 h. The maximum luminance (Lmax) of the display decreased (367-338 cdm(-2)) as a function of time. The minimum luminance remained constant. The maximum non-uniformity coefficient was 11%. Luminance uniformity decreased slightly as a function of time in use. The conformance of the iPad deviated from the GSDF curve at commencement of use. Deviation did not increase as a function of time in use. This study has demonstrated that the iPad display exhibits luminance degradation typical of liquid crystal displays. The Lmax of the iPad fell below the American College of Radiology-AAPM-Society of Imaging Informatics in Medicine recommendations for primary displays (>350 cdm(-2)) at approximately 1000 h in use. The Lmax recommendation for secondary displays (>250 cdm(-2)) was exceeded during the entire study. The maximum non-uniformity coefficient did not exceed the recommendations for either primary or secondary displays. The deviation from the GSDF exceeded the recommendations of the TG18 for use as either a primary or secondary display. The brightness, uniformity and contrast response are reasonably stable over the useful lifetime of the device; however, the device fails to meet the contrast response standard for either a primary or secondary display.
Mutation of Gonadal soma-derived factor induces medaka XY gonads to undergo ovarian development.
Imai, Takuto; Saino, Kentaro; Matsuda, Masaru
2015-11-06
Gonochoristic species have a bipotential gonad that develops into a testis or an ovary. In species whose sex is determined by a genetic factor, the expression of a sex-determining gene is the first cue that directs the development of a bipotential gonad. Subsequent expression of downstream genes induces the gonad to develop into a testis or an ovary. The TGF-ß family member Gonadal soma-derived factor (Gsdf) is thought to be an important gene for gonadal development in teleost fish, and it is expressed at higher levels in the testis than in the ovary from early to mature stages. However, there is little functional information about the gene. In this study, we targeted the Gsdf coding region in the medaka fish Oryzias latipes using transcription activator-like effector nucleases (TALENs) and studied the phenotypes of the Gsdf mutant medaka. Although normal and heterozygous XY gonads developed into a testis, all XY gonads with a homozygous mutation in Gsdf developed into an ovary at early developmental stages. However, two-thirds of Gsdf mutant XY gonads developed into testes in the adult stages. These results demonstrate that although a gonad can develop into a complete testis in the absence of Gsdf, Gsdf function is critical for directing the bipotential gonad at early developmental stages. Therefore, Gsdf is an endogenous inducer of testicular development similar to a master sex-determining gene. Copyright © 2015 Elsevier Inc. All rights reserved.
Gautier, Aude; Le Gac, Florence; Lareyre, Jean-Jacques
2011-02-01
The gonadal soma-derived factor (GSDF) belongs to the transforming growth factor-β superfamily and is conserved in teleostean fish species. Gsdf is specifically expressed in the gonads, and gene expression is restricted to the granulosa and Sertoli cells in trout and medaka. The gsdf gene expression is correlated to early testis differentiation in medaka and was shown to stimulate primordial germ cell and spermatogonia proliferation in trout. In the present study, we show that the gsdf gene localizes to a syntenic chromosomal fragment conserved among vertebrates although no gsdf-related gene is detected on the corresponding genomic region in tetrapods. We demonstrate using quantitative RT-PCR that most of the genes localized in the synteny are specifically expressed in medaka gonads. Gsdf is the only gene of the synteny with a much higher expression in the testis compared to the ovary. In contrast, gene expression pattern analysis of the gsdf surrounding genes (nup54, aff1, klhl8, sdad1, and ptpn13) indicates that these genes are preferentially expressed in the female gonads. The tissue distribution of these genes is highly similar in medaka and zebrafish, two teleostean species that have diverged more than 110 million years ago. The cellular localization of these genes was determined in medaka gonads using the whole-mount in situ hybridization technique. We confirm that gsdf gene expression is restricted to Sertoli and granulosa cells in contact with the premeiotic and meiotic cells. The nup54 gene is expressed in spermatocytes and previtellogenic oocytes. Transcripts corresponding to the ovary-specific genes (aff1, klhl8, and sdad1) are detected only in previtellogenic oocytes. No expression was detected in the gonocytes in 10 dpf embryos. In conclusion, we show that the gsdf gene localizes to a syntenic chromosomal fragment harboring evolutionary conserved genes in vertebrates. These genes are preferentially expressed in previtelloogenic oocytes, and thus, they display a different cellular localization compared to that of the gsdf gene indicating that the later gene is not co-regulated. Interestingly, our study identifies new clustered genes that are specifically expressed in previtellogenic oocytes (nup54, aff1, klhl8, sdad1). Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevins, N; Vanderhoek, M; Lang, S
2014-06-15
Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary andmore » secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruuge, A; Erdi, Y; Mahmood, U
Purpose: The conformance of Primary Diagnostic Monitors (PDMs) to the DICOM GSDF is increasingly required by several state and city regulators. Our purpose was to quantitatively characterize the luminance performance of the internal, built in photometer of BARCO monitors against an externally calibrated luminance meter. Methods: Thirty one PDMs (BARCO) were included in our analysis. An externally calibrated photometer (RaySafe Solo Light) was used to measure the luminance and illuminance values. Measured monitors were located at various hospital sites, radiology physicians’ offices and radiology reading rooms. All measured PDMs were equipped with the manufacturer’s built-in photometers and connected to Barcomore » MediCal QA web service for manual and automatic quality control measurements. PDM combinations included 1, 2 and 4 monitors depending on the location. TG-18 and SMPTE test patterns were used to evaluate monitor performance. Results: All the PDMs exceeded the luminance ratio of 250:1, as required by NYC PDM guidelines. One PDM failed the NYC requirement for the minimal luminance level of 350 cd/m2. As compared to the external photometer, the difference in measurement of the maximum luminance with the built-in photometer was found to exceed 5% on 6 of the PDM measured, with a maximum deviation of 10%. The age of the monitors that failed was on average 5 years. All monitors passed the luminance uniformity test, which was 30% from the center of the monitor to the 4 corner locations. Four PDMs failed the Gray Scale Display Function (GSDF) calibration. Conclusion: For the consistent display of medical images and continued conformance with the DICOM GSDF standard, it is essential to compare the performance of the built-in photometer with an externally calibrated photometer for monitors that are older than 5 years.« less
Autosomal gsdf acts as a male sex initiator in the fish medaka
Zhang, Xi; Guan, Guijun; Li, Mingyou; Zhu, Feng; Liu, Qizhi; Naruse, Kiyoshi; Herpin, Amaury; Nagahama, Yoshitaka; Li, Jiale; Hong, Yunhan
2016-01-01
Sex is pivotal for reproduction, healthcare and evolution. In the fish medaka, the Y-chromosomal dmy (also dmrt1bY) serves the sex determiner, which activates dmrt1 for male sex maintenance. However, how dmy makes the male decision via initiating testicular differentiation has remained unknown. Here we report that autosomal gsdf serves a male sex initiator. Gene addition and deletion revealed that gsdf was necessary and sufficient for maleness via initiating testicular differentiation. We show that gsdf transcription is activated directly by dmy. These results establish the autosomal gsdf as the first male sex initiator. We propose that dmy determines maleness through activating gsdf and dmrt1 without its own participation in developmental processes of sex initiation and maintenance. gsdf may easily become a sex determiner or other autosomal genes can be recruited as new sex determiners to initiate gsdf expression. Our findings offer new insights into molecular mechanisms underlying sex development and evolution of sex-controlling genes in vertebrates. PMID:26813267
NASA Astrophysics Data System (ADS)
Kimpe, Tom; Rostang, Johan; Avanaki, Ali; Espig, Kathryn; Xthona, Albert; Cocuranu, Ioan; Parwani, Anil V.; Pantanowitz, Liron
2014-03-01
Digital pathology systems typically consist of a slide scanner, processing software, visualization software, and finally a workstation with display for visualization of the digital slide images. This paper studies whether digital pathology images can look different when presenting them on different display systems, and whether these visual differences can result in different perceived contrast of clinically relevant features. By analyzing a set of four digital pathology images of different subspecialties on three different display systems, it was concluded that pathology images look different when visualized on different display systems. The importance of these visual differences is elucidated when they are located in areas of the digital slide that contain clinically relevant features. Based on a calculation of dE2000 differences between background and clinically relevant features, it was clear that perceived contrast of clinically relevant features is influenced by the choice of display system. Furthermore, it seems that the specific calibration target chosen for the display system has an important effect on the perceived contrast of clinically relevant features. Preliminary results suggest that calibrating to DICOM GSDF calibration performed slightly worse than sRGB, while a new experimental calibration target CSDF performed better than both DICOM GSDF and sRGB. This result is promising as it suggests that further research work could lead to better definition of an optimized calibration target for digital pathology images resulting in a positive effect on clinical performance.
Naoi, Yutaka; Fujikawa, Akira; Kyoto, Yukishige; Kunishima, Naoaki; Ono, Masahiro; Watanabe, Yukie
2013-01-01
When the Great East Japan Earthquake occurred on March 11, 2011, the Ground Self-Defense Force (GSDF) was dispatched nationally to Northeast area in Japan. The highly trained GSDF members were simultaneously assigned to various missions for the Fukushima Nuclear Power Plants disaster. The missions of GSDF terminated on August 31, 2011. Special medical examinations were conducted for the members as they returned to each military unit. GSDF members who were assigned to the nuclear power plant were at risk of radiation exposure; therefore, pocket dosimeters were used to assess external radiation exposure. A few months after the mission was terminated, measurements of internal radiation exposure were performed. This is the first report of the internal exposure of GSDF members who worked in the restricted radiation contamination area. Here, we report the amounts of internal and external exposure of and the equipment used by the GSDF members.
Zhu, Yefei; Wang, Chunlei; Chen, Xiaowu; Guan, Guijun
2016-07-01
We studied molecular events and potential mechanisms underlying the process of female-to-male sex transformation in the rice field eel (Monopterus albus), a protogynous hermaphrodite fish in which the gonad is initially a female ovary and transforms into male testes. We cloned and identified a novel gonadal soma derived factor (GSDF), which encodes a member of the transforming growth factor-beta superfamily. gsdf expression was measured in gonads of female, intersex and male with reverse transcription-PCR and gsdf's role in sex transformation was studied with qPCR, histological analysis and dual-color in situ hybridization assays and compared to other sex-related genes. gsdf was correlated to Sertoli cell differentiation, indicating involvement in testicular differentiation and sex transformation from female to male in this species. A unique expression pattern reveals a potential role of gsdf essential for the sex transformation of rice field eels.
Horie, Yoshifumi; Myosho, Taijun; Sato, Tadashi; Sakaizumi, Mitsuru; Hamaguchi, Satoshi; Kobayashi, Tohru
2016-11-15
In the inbred HNI-II strain of Oryzias sakaizumii, Dmy and Gsdf are expressed in XY gonads from Stages 35 and 36, respectively, similarly to the inbred Hd-rR strain of Oryzias latipes. However, Dmrt1 respectively becomes detectable at Stage 36 and 5 days post hatching (dph) in the two strains. In XX HNI-II embryos, 17α-methyltestosterone (MT) induces Gsdf mRNA from Stage 36, accompanied by complete sex-reversal in all treated individuals (MT, 10 ng/mL), while Dmrt1 mRNA was first detectable at 5 dph. In XX d-rR, MT induced Gsdf mRNA expression and sex-reversal in only some of the treated individuals. Together, these results suggest the testis differentiation cascade in XY individuals differs between the HNI-II and Hd-rR strains. In addition, it is suggested that androgen-induced XX sex-reversal proceeds via an androgen-Gsdf-Dmrt1 cascade and that Gsdf plays an important role in sex-reversal in medaka. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Horiguchi, Ryo; Nozu, Ryo; Hirai, Toshiaki; Kobayashi, Yasuhisa; Nagahama, Yoshitaka; Nakamura, Masaru
2013-04-01
Sex change in fishes provides a good experimental model for understanding the mechanisms and plasticity of sex determination and differentiation. The three-spot wrasse, Halichoeres trimaculatus is a protogynous hermaphrodite. During sex change from female to male, the ovary is replaced by the testis through the degeneration of oocytes and subsequent spermatogenesis. In the present study, we cloned a cDNA-encoding gonadal soma-derived factor (GSDF) from protogynous wrasse and examined its expression pattern in the sexually mature gonads and the sex-changing gonad induced experimentally by aromatase inhibition. Expression of gsdf was predominantly observed in the testis, and it was mainly localized to the supporting cells surrounding the spermatogonia. In the ovary, only slight expression of gsdf was observed in morphologically undifferentiated supporting cells in contact with oogonia. During sex change, strong expression of gsdf appeared first in the supporting cells surrounding the gonial germ cells before the onset of spermatogenesis. Thereafter, the expression of gsdf continually increased in the supporting cells surrounding the proliferating spermatogonia throughout the sex change. These results suggest that gsdf is involved in the proliferation of spermatogonia and subsequent spermatogenesis in both the testis and the gonad in the early stages of sex change. Copyright © 2013 Wiley Periodicals, Inc.
Preliminary display comparison for dental diagnostic applications
NASA Astrophysics Data System (ADS)
Odlum, Nicholas; Spalla, Guillaume; van Assche, Nele; Vandenberghe, Bart; Jacobs, Reinhilde; Quirynen, Marc; Marchessoux, Cédric
2012-02-01
The aim of this study is to predict the clinical performance and image quality of a display system for viewing dental images. At present, the use of dedicated medical displays is not uniform among dentists - many still view images on ordinary consumer displays. This work investigated whether the use of a medical display improved the perception of dental images by a clinician, compared to a consumer display. Display systems were simulated using the MEdical Virtual Imaging Chain (MEVIC). Images derived from two carefully performed studies on periodontal bone lesion detection and endodontic file length determination, were used. Three displays were selected: a medical grade one and two consumer displays (Barco MDRC-2120, Dell 1907FP and Dell 2007FPb). Some typical characteristics of the displays are evaluated by measurements and simulations like the Modulation Function (MTF), the Noise Power Spectrum (NPS), backlight stability or calibration. For the MTF, the display with the largest pixel pitch has logically the worst MTF. Moreover, the medical grade display has a slightly better MTF and the displays have similar NPS. The study shows the instability effect for the emitted intensity of the consumer displays compared to the medical grade one. Finally the study on the calibration methodology of the display shows that the signal in the dental images will be always more perceivable on the DICOM GSDF display than a gamma 2,2 display.
Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samei, Ehsan; Badano, Aldo; Chakraborty, Dev
Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction withmore » specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L{sub amb}) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m{sup 2}, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u{sup '},v{sup '} color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.« less
United Nations Development Program solicits funds from corporations.
Karliner, J; Srivastava, A; Bruno, K
1999-01-01
The Global Sustainable Development Facility (GSDF) project, a collaboration between the U.N. Development Program and a variety of global corporate sponsors, some with poor human rights, labor, and environmental records, has come under criticism from prestigious nongovernmental organizations around the world. A letter to James Gustave Speth, Administrator of the U.N. Development Program, expresses concern about the threat posed by the GSDF project to the independence and credibility of the U.N. Development Program.
Spatial noise and threshold contrasts in LCD displays
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Krupinski, Elizabeth A.; Chawla, Amarpreet S.; Fan, Jiahua; Gandhi, Kunal
2003-05-01
This paper presents the results of initial physical and psycho-physical evaluations of the noise of high resolution LCDs. 5 LCDs were involved, having 4 different pixel structures. Spatial as well as temporal noise was physically measured with the aid of a high-performance CCD camera. Human contrast sensitivity in the presence of spatial noise was determined psycho-physically using periodic stimuli (square-wave patterns) as well as aperiodic stimuli (squares). For the measurements of the human contrast sensitivity, all LCDs were calibrated to the DICOM 14 Grayscale Standard Display Function (GSDF). The results demonstrate that spatial noise is the dominant noise in all LCDs, while temporal noise is insignificant and plays only a minor part. The magnitude of spatial noise of LCDs is in the range between that of CRTs with a P104 and that of CRTs with a P45. Of particular importance with respect to LCD noise is the contribution of the pixel structure to the Noise Power Spectrum, which shows up as sharp spikes at spatial frequencies beyond the LCDs" Nyquist frequency. The paper does not offer any clues about the importance of these spikes on the human contrast sensitivity.
A virtual image chain for perceived image quality of medical display
NASA Astrophysics Data System (ADS)
Marchessoux, Cédric; Jung, Jürgen
2006-03-01
This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.
Kobayashi, Tohru; Chiba, Ayaka; Sato, Tadashi; Myosho, Taijun; Yamamoto, Jun; Okamura, Tetsuro; Onishi, Yuta; Sakaizumi, Mitsuru; Hamaguchi, Satoshi; Iguchi, Taisen; Horie, Yoshifumi
2017-10-01
Testis-ova differentiation in sexually mature male medaka (Oryzias latipes) is easily induced by estrogenic chemicals, indicating that spermatogonia persist in sexual bipotentiality, even in mature testes in medaka. By contrast, the effects of estrogen on testicular somatic cells associated with testis-ova differentiation in medaka remain unclear. In this study, we focused on the dynamics of sex-related genes (Gsdf, Dmrt1, and Foxl2) expressed in Sertoli cells in the mature testes of adult medaka during estrogen-induced testis-ova differentiation. When mature male medaka were exposed to estradiol benzoate (EB; 800ng/L), testis-ova first appeared after EB treatment for 14days (observed as the first oocytes of the leptotene-zygotene stage). However, the testis remained structurally unchanged, even after EB treatment for 28days. Although Foxl2 is a female-specific sex gene, EB treatment for 7days induced Foxl2/FOXL2 expression in all Sertoli cell-enclosed spermatogonia before testis-ova first appeared; however, Foxl2 was not detected in somatic cells in control testes. Conversely, Sertoli-cell-specific Gsdf mRNA expression levels significantly decreased after EB treatment for 14days, and no changes were observed in DMRT1 localization following EB treatment, whereas Dmrt1 mRNA levels increased significantly. Furthermore, after EB exposure, FOXl2 and DMRT1 were co-localized in Sertoli cells during testis-ova differentiation, although FOXL2 localization was undetectable in Sertoli-cell-enclosed apoptotic testis-ova, whereas DMRT1 remained localized in Sertoli cells. These results indicated for the first time that based on the expression of female-specific sex genes, feminization of Sertoli cells precedes testis-ova differentiation induced by estrogen in mature testes in medaka; however, complete feminization of Sertoli cells was not induced in this study. Additionally, it is suggested strongly that Foxl2 and Gsdf expression constitute potential molecular markers for evaluating the effects of estrogenic chemicals on testicular somatic cells associated with estrogen-induced testis-ova differentiation in mature male medaka. Copyright © 2017 Elsevier B.V. All rights reserved.
Production of Zebrafish Offspring from Cultured Female Germline Stem Cells
Wong, Ten-Tsao; Tesfamichael, Abraham; Collodi, Paul
2013-01-01
Zebrafish female germline stem cell (FGSC) cultures were generated from a transgenic line of fish that expresses Neo and DsRed under the control of the germ cell specific promoter, ziwi [Tg(ziwi:neo);Tg(ziwi:DsRed)]. Homogeneous FGSC cultures were established by G418 selection and continued to express ziwi for more than 6 weeks along with the germ cell markers nanos3, dnd, dazl and vasa. A key component of the cell culture system was the use of a feeder cell line that was initiated from ovaries of a transgenic line of fish [Tg(gsdf:neo)] that expresses Neo controlled by the zebrafish gonadal soma derived factor (gsdf) promoter. The feeder cell line was selected in G418 and engineered to express zebrafish leukemia inhibitory factor (Lif), basic fibroblast growth factor (Fgf2) and glial-cell-line derived neurotrophic factor (Gdnf). These factors were shown to significantly enhance FGSC growth, survival and germline competency in culture. Results from cell transplantation experiments revealed that the cultured FGSCs were able to successfully colonize the gonad of sterile recipient fish and generate functional gametes. Up to 20% of surviving recipient fish that were injected with the cultured FGSCs were fertile and generated multiple batches of normal offspring for at least 6 months. The FGSC cultures will provide an in vitro system for studies of zebrafish germ cell growth and differentiation and their high frequency of germline transmission following transplantation could form the basis of a stem cell-mediated strategy for gene transfer and manipulation of the zebrafish genome. PMID:23671620
Perceptual uniformity of commonly used color spaces
NASA Astrophysics Data System (ADS)
Avanaki, Ali; Espig, Kathryn; Kimpe, Tom; Xthona, Albert; Marchessoux, Cedric; Rostang, Johan; Piepers, Bastian
2014-03-01
Use of color images in medical imaging has increased significantly the last few years. Color information is essential for applications such as ophthalmology, dermatology and clinical photography. Use of color at least brings benefits for other applications such as endoscopy, laparoscopy and digital pathology. Remarkably, as of today, there is no agreed standard on how color information needs to be visualized for medical applications. This lack of standardization results in large variability of how color images are visualized and it makes quality assurance a challenge. For this reason FDA and ICC recently organized a joint summit on color in medical imaging (CMI). At this summit, one of the suggestions was that modalities such as digital pathology could benefit from using a perceptually uniform color space (T. Kimpe, "Color Behavior of Medical Displays," CMI presentation, May 2013). Perceptually uniform spaces have already been used for many years in the radiology community where the DICOM GSDF standard provides linearity in luminance but not in color behavior. In this paper we quantify perceptual uniformity, using CIE's ΔE2000 as a color distance metric, of several color spaces that are typically used for medical applications. We applied our method to theoretical color spaces Gamma 1.8, 2.0, & 2.2, standard sRGB, and DICOM (correction LUT for gray applied to all primaries). In addition, we also measured color spaces (i.e., native behavior) of a high-end medical display (Barco Coronis Fusion 6MP DL, MDCC-6130), and a consumer display (Dell 1907FP). Our results indicate that sRGB & the native color space on the Barco Coronis Fusion exhibit the least non-uniformity within their group. However, the remaining degree of perceptual non-uniformity is still significant and there is room for improvement.
Mutation of foxl2 or cyp19a1a Results in Female to Male Sex Reversal in XX Nile Tilapia.
Zhang, Xianbo; Li, Mengru; Ma, He; Liu, Xingyong; Shi, Hongjuan; Li, Minghui; Wang, Deshou
2017-08-01
It is well accepted that Forkhead box protein L2 (Foxl2) and aromatase (Cyp19a1; the enzyme responsible for estrogen synthesis) are critical for ovarian development in vertebrates. Knockouts of Foxl2 and Cyp19a1 in goat, mouse, and zebrafish have revealed similar but not identical functions across species. Functional analyses of these two genes in other animals are needed to elucidate their conserved roles in vertebrate sexual development. In this study, we established foxl2 and cyp19a1a mutant lines in Nile tilapia. Both foxl2-/- and cyp19a1a-/- XX fish displayed female-to-male sex reversal. Sf1, Dmrt1, and Gsdf were upregulated in the foxl2-/- and the cyp19a1a-/- XX gonads. Downregulation of Cyp19a1a and serum estradiol-17β level, and upregulation of Cyp11b2 and serum 11-ketotestosterone level were observed in foxl2-/- XX fish. The mutant phenotype of foxl2-/- XX individuals could be rescued by 17β-estradiol treatment from 5 to 30 days after hatching (dah). Upregulation of Star1, the enzyme involved in androgen production in tilapia, was also observed in the foxl2-/- XX gonad at 30 and 90 dah. In vitro promoter analyses consistently demonstrated that Foxl2 could suppress the transcription of star1 in a dose-dependent manner. In addition, compared with the control XX gonad, fewer germ cells were detected in the foxl2-/- XX, cyp19a1a-/- XX, and control XY gonads 10 dah. These results demonstrate that Foxl2 promotes ovarian development by upregulating Cyp19a1a expression and repressing male pathway gene expression. These results extend the study of Foxl2 and Cyp19a1a loss of function to a commercially important fish species. Copyright © 2017 Endocrine Society.
Tao, Wenjing; Chen, Jinlin; Tan, Dejie; Yang, Jing; Sun, Lina; Wei, Jing; Conte, Matthew A; Kocher, Thomas D; Wang, Deshou
2018-05-15
The factors determining sex in teleosts are diverse. Great efforts have been made to characterize the underlying genetic network in various species. However, only seven master sex-determining genes have been identified in teleosts. While the function of a few genes involved in sex determination and differentiation has been studied, we are far from fully understanding how genes interact to coordinate in this process. To enable systematic insights into fish sexual differentiation, we generated a dynamic co-expression network from tilapia gonadal transcriptomes at 5, 20, 30, 40, 90, and 180 dah (days after hatching), plus 45 and 90 dat (days after treatment) and linked gene expression profiles to both development and sexual differentiation. Transcriptomic profiles of female and male gonads at 5 and 20 dah exhibited high similarities except for a small number of genes that were involved in sex determination, while drastic changes were observed from 90 to 180 dah, with a group of differently expressed genes which were involved in gonadal differentiation and gametogenesis. Weighted gene correlation network analysis identified changes in the expression of Borealin, Gtsf1, tesk1, Zar1, Cdn15, and Rpl that were correlated with the expression of genes previously known to be involved in sex differentiation, such as Foxl2, Cyp19a1a, Gsdf, Dmrt1, and Amh. Global gonadal gene expression kinetics during sex determination and differentiation have been extensively profiled in tilapia. These findings provide insights into the genetic framework underlying sex determination and sexual differentiation, and expand our current understanding of developmental pathways during teleost sex determination.
2017-06-01
DEW Directed-Energy Weapons DOD Department of Defense DPJ Democratic Party of Japan EM Electro-magnetic FMS Foreign Military Sales GSDF Ground...data.oecd.org/japan.htm. 75 Chris Matthews, “Forget Greece, Japan is the World’s Real Economic Time Bomb ,” Fortune, February 26, 2015, http...fortune.com/2015/02/26/japan-economic-time- bomb /. 25 to fund repair facilities, buy parts, or pay contractors? In terms of operating costs, will the JSDF
Ambient lighting: setting international standards for the viewing of softcopy chest images
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Ryan, John; Evanoff, Micheal G.; Keeling, Aoife; Chakraborty, Dev; Manning, David; Brennan, Patrick C.
2007-03-01
Clinical radiological judgments are increasingly being made on softcopy LCD monitors. These monitors are found throughout the hospital environment in radiological reading rooms, outpatient clinics and wards. This means that ambient lighting where clinical judgments from images are made can vary widely. Inappropriate ambient lighting has several deleterious effects: monitor reflections reduce contrast; veiling glare adds brightness; dynamic range and detectability of low contrast objects is limited. Radiological images displayed on LCDs are more sensitive to the impact of inappropriate ambient lighting and with these devices problems described above are often more evident. The current work aims to provide data on optimum ambient lighting, based on lesions within chest images. The data provided may be used for the establishment of workable ambient lighting standards. Ambient lighting at 30cms from the monitor was set at 480 Lux (office lighting) 100 Lux (WHO recommendations), 40 Lux and <10 Lux. All monitors were calibrated to DICOM part 14 GSDF. Sixty radiologists were presented with 30 chest images, 15 images having simulated nodular lesions of varying subtlety and size. Lesions were positioned in accordance with typical clinical presentation and were validated radiologically. Each image was presented for 30 seconds and viewers were asked to identify and score any visualized lesion from 1-4 to indicate confidence level of detection. At the end of the session, sensitivity and specificity were calculated. Analysis of the data suggests that visualization of chest lesions is affected by inappropriate lighting with chest radiologists demonstrating greater ambient lighting dependency. JAFROC analyses are currently being performed.
Probability of the moiré effect in barrier and lenticular autostereoscopic 3D displays.
Saveljev, Vladimir; Kim, Sung-Kyu
2015-10-05
The probability of the moiré effect in LCD displays is estimated as a function of angle based on the experimental data; a theoretical function (node spacing) is proposed basing on the distance between nodes. Both functions are close to each other. The connection between the probability of the moiré effect and the Thomae's function is also found. The function proposed in this paper can be used in the minimization of the moiré effect in visual displays, especially in autostereoscopic 3D displays.
Environmental Control Subsystem Development
NASA Technical Reports Server (NTRS)
Laidlaw, Jacob; Zelik, Jonathan
2017-01-01
Kennedy Space Center's Launch Pad 39B, part of Launch Complex 39, is currently undergoing construction to prepare it for NASA's Space Launch System missions. The Environmental Control Subsystem, which provides the vehicle with an air or nitrogen gas environment, required development of its local and remote display screens. The remote displays, developed by NASA contractors and previous interns, were developed without complete functionality; the remote displays were revised, adding functionality to over 90 displays. For the local displays, multiple test procedures were developed to assess the functionality of the screens, as well as verify requirements. One local display screen was also developed.
Polyvalent Display of Biomolecules on Live Cells.
Shi, Peng; Zhao, Nan; Lai, Jinping; Coyne, James; Gaddes, Erin R; Wang, Yong
2018-06-04
Surface display of biomolecules on live cells offers new opportunities to treat human diseases and perform basic studies. Existing methods are primarily focused on monovalent functionalization, that is, the display of single biomolecules across the cell surface. Here we show that the surface of live cells can be functionalized to display polyvalent biomolecular structures through two-step reactions under physiological conditions. This polyvalent functionalization enables the cell surface to recognize the microenvironment one order of magnitude more effectively than with monovalent functionalization. Thus, polyvalent display of biomolecules on live cells holds great potential for various biological and biomedical applications. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Effect of Display Color on Pilot Performance and Describing Functions
NASA Technical Reports Server (NTRS)
Chase, Wendell D.
1997-01-01
A study has been conducted with the full-spectrum, calligraphic, computer-generated display system to determine the effect of chromatic content of the visual display upon pilot performance during the landing approach maneuver. This study utilizes a new digital chromatic display system, which has previously been shown to improve the perceived fidelity of out-the-window display scenes, and presents the results of an experiment designed to determine the effects of display color content by the measurement of both vertical approach performance and pilot-describing functions. This method was selected to more fully explore the effects of visual color cues used by the pilot. Two types of landing approaches were made: dynamic and frozen range, with either a landing approach scene or a perspective array display. The landing approach scene was presented with either red runway lights and blue taxiway lights or with the colors reversed, and the perspective array with red lights, blue lights, or red and blue lights combined. The vertical performance measures obtained in this experiment indicated that the pilots performed best with the blue and red/blue displays. and worst with the red displays. The describing-function system analysis showed more variation with the red displays. The crossover frequencies were lowest with the red displays and highest with the combined red/blue displays, which provided the best overall tracking, performance. Describing-function performance measures, vertical performance measures, and pilot opinion support the hypothesis that specific colors in displays can influence the pilots' control characteristics during the final approach.
Martens, Jason P; Tracy, Jessica L; Shariff, Azim F
2012-01-01
A growing body of research suggests that pride and shame are associated with distinct, cross-culturally recognised nonverbal expressions, which are spontaneously displayed in situations of success and failure, respectively. Here, we review these findings, then offer a theoretical account of the adaptive benefits of these displays. We argue that both pride and shame expressions function as social signals that benefit both observers and expressers. Specifically, pride displays function to signal high status, which benefits displayers by according them deference from others, and benefits observers by affording them valuable information about social-learning opportunities. Shame displays function to appease others after a social transgression, which benefits displayers by allowing them to avoid punishment and negative appraisals, and observers by easing their identification of committed group members and followers.
Regularity Results for a Class of Functionals with Non-Standard Growth
NASA Astrophysics Data System (ADS)
Acerbi, Emilio; Mingione, Giuseppe
We consider the integral functional
NASA Technical Reports Server (NTRS)
Chase, W. D.
1976-01-01
The use of blue and red color in out-of-window cockpit displays, in full-spectrum calligraphic computer-generated display systems, is studied with attention given to pilot stereographic depth perception and response to visual cues. Displays for vertical approach, with dynamic and frozen-range landing approach and perspective arrays, are analyzed. Pilot transfer function and the transfer function associated with the contrasted approach and perspective arrays are discussed. Out-of-window blue lights are perceived by pilots as indicating greater distance depth, red lights as indicating proximity. The computer-generated chromatic display was adapted to flight simulators for the tests.
A review of contemporary methods for the presentation of scientific uncertainty.
Makinson, K A; Hamby, D M; Edwards, J A
2012-12-01
Graphic methods for displaying uncertainty are often the most concise and informative way to communicate abstract concepts. Presentation methods currently in use for the display and interpretation of scientific uncertainty are reviewed. Numerous subjective and objective uncertainty display methods are presented, including qualitative assessments, node and arrow diagrams, standard statistical methods, box-and-whisker plots,robustness and opportunity functions, contribution indexes, probability density functions, cumulative distribution functions, and graphical likelihood functions.
Evaluation of stereoscopic display with visual function and interview
NASA Astrophysics Data System (ADS)
Okuyama, Fumio
1999-05-01
The influence of binocular stereoscopic (3D) television display on the human eye were compared with one of a 2D display, using human visual function testing and interviews. A 40- inch double lenticular display was used for 2D/3D comparison experiments. Subjects observed the display for 30 minutes at a distance 1.0 m, with a combination of 2D material and one of 3D material. The participants were twelve young adults. Main optometric test with visual function measured were visual acuity, refraction, phoria, near vision point, accommodation etc. The interview consisted of 17 questions. Testing procedures were performed just before watching, just after watching, and forty-five minutes after watching. Changes in visual function are characterized as prolongation of near vision point, decrease of accommodation and increase in phoria. 3D viewing interview results show much more visual fatigue in comparison with 2D results. The conclusions are: 1) change in visual function is larger and visual fatigue is more intense when viewing 3D images. 2) The evaluation method with visual function and interview proved to be very satisfactory for analyzing the influence of stereoscopic display on human eye.
ORF phage display to identify cellular proteins with different functions.
Li, Wei
2012-09-01
Open reading frame (ORF) phage display is a new branch of phage display aimed at improving its efficiency to identify cellular proteins with specific binding or functional activities. Despite the success of phage display with antibody libraries and random peptide libraries, phage display with cDNA libraries of cellular proteins identifies a high percentage of non-ORF clones encoding unnatural short peptides with minimal biological implications. This is mainly because of the uncontrollable reading frames of cellular proteins in conventional cDNA libraries. ORF phage display solves this problem by eliminating non-ORF clones to generate ORF cDNA libraries. Here I summarize the procedures of ORF phage display, discuss the factors influencing its efficiency, present examples of its versatile applications, and highlight evidence of its capability of identifying biologically relevant cellular proteins. ORF phage display coupled with different selection strategies is capable of delineating diverse functions of cellular proteins with unique advantages. Copyright © 2012 Elsevier Inc. All rights reserved.
Geffroy, Benjamin; Guilbaud, Florian; Amilhat, Elsa; Beaulaton, Laurent; Vignon, Matthias; Huchet, Emmanuel; Rives, Jacques; Bobe, Julien; Fostier, Alexis; Guiguen, Yann; Bardonnet, Agnès
2016-01-01
Environmental sex determination (ESD) has been detected in a range of vertebrate reptile and fish species. Eels are characterized by an ESD that occurs relatively late, since sex cannot be histologically determined before individuals reach 28 cm. Because several eel species are at risk of extinction, assessing sex at the earliest stage is a crucial management issue. Based on preliminary results of RNA sequencing, we targeted genes susceptible to be differentially expressed between ovaries and testis at different stages of development. Using qPCR, we detected testis-specific expressions of dmrt1, amh, gsdf and pre-miR202 and ovary-specific expressions were obtained for zar1, zp3 and foxn5. We showed that gene expressions in the gonad of intersexual eels were quite similar to those of males, supporting the idea that intersexual eels represent a transitional stage towards testicular differentiation. To assess whether these genes would be effective early molecular markers, we sampled juvenile eels in two locations with highly skewed sex ratios. The combined expression of six of these genes allowed the discrimination of groups according to their potential future sex and thus this appears to be a useful tool to estimate sex ratios of undifferentiated juvenile eels. PMID:27658729
Kitano, Takeshi; Hayashi, Yuki; Shiraishi, Eri; Kamei, Yasuhiro
2012-10-01
Medaka (Oryzias latipes) is a teleost fish with an XX/XY sex determination system. Recently, it was reported that XX medaka can be sex-reversed into phenotypic males by exposure to high water temperature (HT) during gonadal sex differentiation, possibly by elevation of cortisol, the major glucocorticoid produced by the interrenal cells in teleosts. Yet, it remains unclear how the elevation of cortisol levels by HT causes female-to-male sex reversal. This paper reports that exposure to cortisol or HT after hatching inhibited both the proliferation of female-type germ cells and the expression of ovarian-type aromatase (cyp19a1), which encodes a steroidogenic enzyme responsible for the conversion of androgens to estrogens, and induced the expression of gonadal soma-derived growth factor (gsdf) in XX gonads during gonadal sex differentiation. In contrast, exposure to either cortisol or HT in combination with 17β-estradiol (E2) did not produce these effects. Moreover, E2 completely rescued cortisol- and HT-induced masculinization of XX medaka. These results strongly suggest that cortisol and HT cause female-to-male sex reversal in medaka by suppression of cyp19a1 expression, with a resultant inhibition of estrogen biosynthesis. This mechanism may be common among animals with temperature-dependent sex determination. Copyright © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Geffroy, Benjamin; Guilbaud, Florian; Amilhat, Elsa; Beaulaton, Laurent; Vignon, Matthias; Huchet, Emmanuel; Rives, Jacques; Bobe, Julien; Fostier, Alexis; Guiguen, Yann; Bardonnet, Agnès
2016-09-01
Environmental sex determination (ESD) has been detected in a range of vertebrate reptile and fish species. Eels are characterized by an ESD that occurs relatively late, since sex cannot be histologically determined before individuals reach 28 cm. Because several eel species are at risk of extinction, assessing sex at the earliest stage is a crucial management issue. Based on preliminary results of RNA sequencing, we targeted genes susceptible to be differentially expressed between ovaries and testis at different stages of development. Using qPCR, we detected testis-specific expressions of dmrt1, amh, gsdf and pre-miR202 and ovary-specific expressions were obtained for zar1, zp3 and foxn5. We showed that gene expressions in the gonad of intersexual eels were quite similar to those of males, supporting the idea that intersexual eels represent a transitional stage towards testicular differentiation. To assess whether these genes would be effective early molecular markers, we sampled juvenile eels in two locations with highly skewed sex ratios. The combined expression of six of these genes allowed the discrimination of groups according to their potential future sex and thus this appears to be a useful tool to estimate sex ratios of undifferentiated juvenile eels.
Multifunctional recombinant phycobiliprotein-based fluorescent constructs and phycobilisome display
Glazer, Alexander N.; Cai, Yuping
2007-01-30
The invention provides multifunctional fusion constructs which are rapidly incorporated into a macromolecular structure such as a phycobilisome such that the fusion proteins are separated from one another and unable to self-associate. The invention provides methods and compositions for displaying a functional polypeptide domain on an oligomeric phycobiliprotein, including fusion proteins comprising a functional displayed domain and a functional phycobiliprotein domain incorporated in a functional oligomeric phycobiliprotein. The fusion proteins provide novel specific labeling reagents.
Multifunctional recombinant phycobiliprotein-based fluorescent constructs and phycobilisome display
Glazer, Alexander N.; Cai, Yuping
2007-02-13
The invention provides multifunctional fusion constructs which are rapidly incorporated into a macromolecular structure such as a phycobilisome such that the fusion proteins are separated from one another and unable to self-associate. The invention provides methods and compositions for displaying a functional polypeptide domain on an oligomeric phycobiliprotein. including fusion proteins comprising a functional displayed domain and a functional phycobiliprotein domain incorporated in a functional oligomeric phycobiliprotein. The fusion proteins provide novel specific labeling reagents.
Multifunctional recombinant phycobiliprotein-based fluorescent constructs and phycobilisome display
Glazer, Alexander N.; Cai, Yuping
2003-11-18
The invention provides multifunctional fusion constructs which are rapidly incorporated into a macromolecular structure such as a phycobilisome such that the fusion proteins are separated from one another and unable to self-associate. The invention provides methods and compositions for displaying a functional polypeptide domain on an oligomeric phycobiliprotein, including fusion proteins comprising a functional displayed domain and a functional phycobiliprotein domain incorporated in a functional oligomeric phycobiliprotein. The fusion proteins provide novel specific labeling reagents.
Method and apparatus for calibrating a tiled display
NASA Technical Reports Server (NTRS)
Chen, Chung-Jen (Inventor); Johnson, Michael J. (Inventor); Chandrasekhar, Rajesh (Inventor)
2001-01-01
A display system that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, one or more cameras are provided to capture an image of the display screen. The resulting captured image is processed to identify any non-desirable characteristics, including visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal that is provided to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and other visible artifacts.
Freyhult, Eva; Moulton, Vincent; Ardell, David H.
2006-01-01
Sequence logos are stacked bar graphs that generalize the notion of consensus sequence. They employ entropy statistics very effectively to display variation in a structural alignment of sequences of a common function, while emphasizing its over-represented features. Yet sequence logos cannot display features that distinguish functional subclasses within a structurally related superfamily nor do they display under-represented features. We introduce two extensions to address these needs: function logos and inverse logos. Function logos display subfunctions that are over-represented among sequences carrying a specific feature. Inverse logos generalize both sequence logos and function logos by displaying under-represented, rather than over-represented, features or functions in structural alignments. To make inverse logos, a compositional inverse is applied to the feature or function frequency distributions before logo construction, where a compositional inverse is a mathematical transform that makes common features or functions rare and vice versa. We applied these methods to a database of structurally aligned bacterial tDNAs to create highly condensed, birds-eye views of potentially all so-called identity determinants and antideterminants that confer specific amino acid charging or initiator function on tRNAs in bacteria. We recovered both known and a few potentially novel identity elements. Function logos and inverse logos are useful tools for exploratory bioinformatic analysis of structure–function relationships in sequence families and superfamilies. PMID:16473848
Automated system function allocation and display format: Task information processing requirements
NASA Technical Reports Server (NTRS)
Czerwinski, Mary P.
1993-01-01
An important consideration when designing the interface to an intelligent system concerns function allocation between the system and the user. The display of information could be held constant, or 'fixed', leaving the user with the task of searching through all of the available information, integrating it, and classifying the data into a known system state. On the other hand, the system, based on its own intelligent diagnosis, could display only relevant information in order to reduce the user's search set. The user would still be left the task of perceiving and integrating the data and classifying it into the appropriate system state. Finally, the system could display the patterns of data. In this scenario, the task of integrating the data is carried out by the system, and the user's information processing load is reduced, leaving only the tasks of perception and classification of the patterns of data. Humans are especially adept at this form of display processing. Although others have examined the relative effectiveness of alphanumeric and graphical display formats, it is interesting to reexamine this issue together with the function allocation problem. Currently, Johnson Space Center is the test site for an intelligent Thermal Control System (TCS), TEXSYS, being tested for use with Space Station Freedom. Expert TCS engineers, as well as novices, were asked to classify several displays of TEXSYS data into various system states (including nominal and anomalous states). Three different display formats were used: fixed, subset, and graphical. The hypothesis tested was that the graphical displays would provide for fewer errors and faster classification times by both experts and novices, regardless of the kind of system state represented within the display. The subset displays were hypothesized to be the second most effective display format/function allocation condition, based on the fact that the search set is reduced in these displays. Both the subset and the graphic display conditions were hypothesized to be processed more efficiently than the fixed display conditions.
Ko, Hyeok-Jin; Park, Eunhye; Song, Joseph; Yang, Taek Ho; Lee, Hee Jong; Kim, Kyoung Heon
2012-01-01
Autotransporters have been employed as the anchoring scaffold for cell surface display by replacing their passenger domains with heterologous proteins to be displayed. We adopted an autotransporter (YfaL) of Escherichia coli for the cell surface display system. The critical regions in YfaL for surface display were identified for the construction of a ligation-independent cloning (LIC)-based display system. The designed system showed no detrimental effect on either the growth of the host cell or overexpressing heterologous proteins on the cell surface. We functionally displayed monomeric red fluorescent protein (mRFP1) as a reporter protein and diverse agarolytic enzymes from Saccharophagus degradans 2-40, including Aga86C and Aga86E, which previously had failed to be functional expressed. The system could display different sizes of proteins ranging from 25.3 to 143 kDa. We also attempted controlled release of the displayed proteins by incorporating a tobacco etch virus protease cleavage site into the C termini of the displayed proteins. The maximum level of the displayed protein was 6.1 × 104 molecules per a single cell, which corresponds to 5.6% of the entire cell surface of actively growing E. coli. PMID:22344647
Solving bezel reliability and CRT obsolescence
NASA Astrophysics Data System (ADS)
Schwartz, Richard J.; Bowen, Arlen R.; Knowles, Terry
2003-09-01
Scientific Research Corporation designed a Smart Multi-Function Color Display with Positive Pilot Feedback under the funding of an U. S. Navy Small Business Innovative Research program. The Smart Multi-Function Color Display can replace the obsolete monochrome Cathode Ray Tube display currently on the T-45C aircraft built by Boeing. The design utilizes a flat panel color Active Matrix Liquid Crystal Display and TexZec's patented Touch Thru Metal bezel technology providing both visual and biomechanical feedback to the pilot in a form, fit, and function replacement to the current T-45C display. Use of an existing color AMLCD, requires the least adaptation to fill the requirements of this application, thereby minimizing risk associated with developing a new display technology and maximizing the investment in improved user interface technology. The improved user interface uses TexZec's Touch Thru Metal technology to eliminate all of the moving parts that traditionally have limited Mean-Time-Between-Failure. The touch detection circuit consists of Commercial-Off-The-Shelf components, creating touch detection circuitry, which is simple and durable. This technology provides robust switch activation and a high level of environmental immunity, both mechanical and electrical. Replacement of all the T-45C multi-function displays with this design will improve the Mean-Time-Between-Failure and drastically reduce display life cycle costs. The design methodology described in this paper can be adapted to any new or replacement display.
Display nonlinearity in digital image processing for visual communications
NASA Astrophysics Data System (ADS)
Peli, Eli
1992-11-01
The luminance emitted from a cathode ray tube (CRT) display is a nonlinear function (the gamma function) of the input video signal voltage. In most analog video systems, compensation for this nonlinear transfer function is implemented in the camera amplifiers. When CRT displays are used to present psychophysical stimuli in vision research, the specific display nonlinearity usually is measured and accounted for to ensure that the luminance of each pixel in the synthetic image property represents the intended value. However, when using digital image processing, the linear analog-to-digital converters store a digital image that is nonlinearly related to the displayed or recorded image. The effect of this nonlinear transformation on a variety of image-processing applications used in visual communications is described.
Display nonlinearity in digital image processing for visual communications
NASA Astrophysics Data System (ADS)
Peli, Eli
1991-11-01
The luminance emitted from a cathode ray tube, (CRT) display is a nonlinear function (the gamma function) of the input video signal voltage. In most analog video systems, compensation for this nonlinear transfer function is implemented in the camera amplifiers. When CRT displays are used to present psychophysical stimuli in vision research, the specific display nonlinearity usually is measured and accounted for to ensure that the luminance of each pixel in the synthetic image properly represents the intended value. However, when using digital image processing, the linear analog-to-digital converters store a digital image that is nonlinearly related to the displayed or recorded image. This paper describes the effect of this nonlinear transformation on a variety of image-processing applications used in visual communications.
Two dimensional eye tracking: Sampling rate of forcing function
NASA Technical Reports Server (NTRS)
Hornseth, J. P.; Monk, D. L.; Porterfield, J. L.; Mcmurry, R. L.
1978-01-01
A study was conducted to determine the minimum update rate of a forcing function display required for the operator to approximate the tracking performance obtained on a continuous display. In this study, frequency analysis was used to determine whether there was an associated change in the transfer function characteristics of the operator. It was expected that as the forcing function display update rate was reduced, from 120 to 15 samples per second, the operator's response to the high frequency components of the forcing function would show a decrease in gain, an increase in phase lag, and a decrease in coherence.
Functional Proteomics to Identify Moderators of CD8+ T-Cell Function in Melanoma
2013-09-01
could then be used to develop imaging agents that are targeted to the TILs. We used an M13 phage vector, which displays a pentavalent peptide as...of the identified transcript. To directly indentify inhibitory molecules, we have proposed to use phage - display expression libraries to perform...of TCD8. 3. To determine the ligands for molecules that can modulate the TCD8 functional state. Body: A. Phage Screen Summary Phage display
Double-heterojunction nanorod light-responsive LEDs for display applications.
Oh, Nuri; Kim, Bong Hoon; Cho, Seong-Yong; Nam, Sooji; Rogers, Steven P; Jiang, Yiran; Flanagan, Joseph C; Zhai, You; Kim, Jae-Hwan; Lee, Jungyup; Yu, Yongjoon; Cho, Youn Kyoung; Hur, Gyum; Zhang, Jieqian; Trefonas, Peter; Rogers, John A; Shim, Moonsub
2017-02-10
Dual-functioning displays, which can simultaneously transmit and receive information and energy through visible light, would enable enhanced user interfaces and device-to-device interactivity. We demonstrate that double heterojunctions designed into colloidal semiconductor nanorods allow both efficient photocurrent generation through a photovoltaic response and electroluminescence within a single device. These dual-functioning, all-solution-processed double-heterojunction nanorod light-responsive light-emitting diodes open feasible routes to a variety of advanced applications, from touchless interactive screens to energy harvesting and scavenging displays and massively parallel display-to-display data communication. Copyright © 2017, American Association for the Advancement of Science.
NASA Technical Reports Server (NTRS)
Hoh, Roger H.; Smith, James C.; Hinton, David A.
1987-01-01
An analytical and experimental research program was conducted to develop criteria for pilot interaction with advanced controls and displays in single pilot instrument flight rules (SPIFR) operations. The analytic phase reviewed fundamental considerations for pilot workload taking into account existing data, and using that data to develop a divided attention SPIFR pilot workload model. The pilot model was utilized to interpret the two experimental phases. The first experimental phase was a flight test program that evaluated pilot workload in the presence of current and near-term displays and autopilot functions. The second experiment was conducted on a King Air simulator, investigating the effects of co-pilot functions in the presence of very high SPIFR workload. The results indicate that the simplest displays tested were marginal for SPIFR operations. A moving map display aided the most in mental orientation, but had inherent deficiencies as a stand alone replacement for an HSI. Autopilot functions were highly effective for reducing pilot workload. The simulator tests showed that extremely high workload situations can be adequately handled when co-pilot functions are provided.
Method and system for providing work machine multi-functional user interface
Hoff, Brian D [Peoria, IL; Akasam, Sivaprasad [Peoria, IL; Baker, Thomas M [Peoria, IL
2007-07-10
A method is performed to provide a multi-functional user interface on a work machine for displaying suggested corrective action. The process includes receiving status information associated with the work machine and analyzing the status information to determine an abnormal condition. The process also includes displaying a warning message on the display device indicating the abnormal condition and determining one or more corrective actions to handle the abnormal condition. Further, the process includes determining an appropriate corrective action among the one or more corrective actions and displaying a recommendation message on the display device reflecting the appropriate corrective action. The process may also include displaying a list including the remaining one or more corrective actions on the display device to provide alternative actions to an operator.
Visualizing the anatomical-functional correlation of the human brain
NASA Astrophysics Data System (ADS)
Chang, YuKuang; Rockwood, Alyn P.; Reiman, Eric M.
1995-04-01
Three-dimensional tomographic images obtained from different modalities or from the same modality at different times provide complementary information. For example, while PET shows brain function, images from MRI identify anatomical structures. In this paper, we investigate the problem of displaying available information about structures and function together. Several steps are described to achieve our goal. These include segmentation of the data, registration, resampling, and display. Segmentation is used to identify brain tissue from surrounding tissues, especially in the MRI data. Registration aligns the different modalities as closely as possible. Resampling arises from the registration since two data sets do not usually correspond and the rendering method is most easily achieved if the data correspond to the same grid used in display. We combine several techniques to display the data. MRI data is reconstructed from 2D slices into 3D structures from which isosurfaces are extracted and represented by approximating polygonalizations. These are then displayed using standard graphics pipelines including shaded and transparent images. PET data measures the qualitative rates of cerebral glucose utilization or oxygen consumption. PET image is best displayed as a volume of luminous particles. The combination of both display methods allows the viewer to compare the functional information contained in the PET data with the anatomically more precise MRI data.
NASA Astrophysics Data System (ADS)
Kallies, J.; Özlük, A.; Peter, M.; Snyder, C.
Let
Functional display of family 11 endoxylanases on the surface of phage M13.
Beliën, T; Hertveldt, K; Van den Brande, K; Robben, J; Van Campenhout, S; Volckaert, G
2005-02-09
Two family 11 endoxylanases (EC 3.2.1.8) were functionally displayed on the surface of bacteriophage M13. The genes encoding endo-1,4-xylanase I from Aspergillus niger (ExlA) and endo-1,4-xylanase A from Bacillus subtilis (XynA) were fused to the gene encoding the minor coat protein g3p in phagemid vector pHOS31. Phage rescue resulted in functional monovalent display of the enzymes as was demonstrated by three independent tests. Firstly, purified recombinant phage particles showed a clear hydrolytic activity in an activity assay based on insoluble, chromagenic arabinoxylan substrate. Secondly, specific binding of endoxylanase displaying phages to immobilized endoxylanase inhibitors was demonstrated by interaction ELISA. Finally, two rounds of selection and amplification in a biopanning procedure against immobilized endoxylanase inhibitor were performed. Phages displaying endoxylanases were strongly enriched from background phages displaying unrelated proteins. These results open perspectives to use phage display for analysing protein-protein interactions at the interface between endoxylanases and their inhibitors. In addition, this technology should enable engineering of endoxylanases into novel variants with altered binding properties towards endoxylanase inhibitors.
Pilot stereotypes for navigation symbols on electronic displays
DOT National Transportation Integrated Search
2006-09-20
There is currently no common symbology standard for the : electronic display of navigation information. The wide : range of display technologies and the different functions : these displays support make it difficult to design symbols : that are easil...
Begeer, Sander; Banerjee, Robin; Rieffe, Carolien; Terwogt, Mark Meerum; Potharst, Eva; Stegge, Hedy; Koot, Hans M
2011-08-01
Two studies examined the understanding and self-reported use of rules for the expressive display of emotions in children with high functioning autism spectrum disorders (HFASD) and in typically developing children. In Study 1, children from the two groups reported display rules equally often when presented with hypothetical situations that provided clear motives for using display rules, although emotion-masking displays were more commonly identified for vignettes with prosocial rather than self-protective motives. In Study 2, children were interviewed about display rule use in real life. Children with HFASD reported display rules less often, included more prototypical examples, and referred less often to prosocial motives than typically developing children. Children with HFASD appear to be aware of display rules, but are less adept at identifying the interpersonal functions of such rules than their typically developing peers.
36 CFR 1193.43 - Output, display, and control functions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...
36 CFR 1193.43 - Output, display, and control functions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...
36 CFR 1193.43 - Output, display, and control functions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...
36 CFR 1193.43 - Output, display, and control functions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... functions. 1193.43 Section 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND TRANSPORTATION... and Usability § 1193.43 Output, display, and control functions. All information necessary to operate... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...
NASA Technical Reports Server (NTRS)
Holzhausen, K. P.; Gaertner, K. P.
1985-01-01
A significant problem concerning the integration of display and switching functions is related to the fact that numerous informative data which have to be processed by man must be read from only a few display devices. A satisfactory ergonomic design of integrated display devices and keyboards is in many cases difficult, because not all functions which can be displayed and selected are simultaneously available. A technical solution which provides an integration of display and functional elements on the basis of the highest flexibility is obtained by using a cathode ray tube with a touch-sensitive screen. The employment of an integrated data input/output system is demonstrated for the cases of onboard and ground-based flight control. Ergonomic studies conducted to investigate the suitability of an employment of touch-sensitive screens are also discussed.
Multi-Function Displays: A Guide for Human Factors Evaluation
2013-11-01
mental workload in rotary wing aircraft . Ergonomics , 36, 1121 - 40. Smith, S., & Mosier, J. (1984). Design guidelines for the user interface for...Monterey Technologies, Inc., except one designated by (*), who is from CAMI. 16. Abstract This guide is designed to assist aircraft ...section. 17. Key Words 18. Distribution Statement Multi-Function Displays, Display Design , Avionics, Human Factors Criteria, Aircraft
The Real Time Display Builder (RTDB)
NASA Technical Reports Server (NTRS)
Kindred, Erick D.; Bailey, Samuel A., Jr.
1989-01-01
The Real Time Display Builder (RTDB) is a prototype interactive graphics tool that builds logic-driven displays. These displays reflect current system status, implement fault detection algorithms in real time, and incorporate the operational knowledge of experienced flight controllers. RTDB utilizes an object-oriented approach that integrates the display symbols with the underlying operational logic. This approach allows the user to specify the screen layout and the driving logic as the display is being built. RTDB is being developed under UNIX in C utilizing the MASSCOMP graphics environment with appropriate functional separation to ease portability to other graphics environments. RTDB grew from the need to develop customized real-time data-driven Space Shuttle systems displays. One display, using initial functionality of the tool, was operational during the orbit phase of STS-26 Discovery. RTDB is being used to produce subsequent displays for the Real Time Data System project currently under development within the Mission Operations Directorate at NASA/JSC. The features of the tool, its current state of development, and its applications are discussed.
Identifying Bacterial Immune Evasion Proteins Using Phage Display.
Fevre, Cindy; Scheepmaker, Lisette; Haas, Pieter-Jan
2017-01-01
Methods aimed at identification of immune evasion proteins are mainly rely on in silico prediction of sequence, structural homology to known evasion proteins or use a proteomics driven approach. Although proven successful these methods are limited by a low efficiency and or lack of functional identification. Here we describe a high-throughput genomic strategy to functionally identify bacterial immune evasion proteins using phage display technology. Genomic bacterial DNA is randomly fragmented and ligated into a phage display vector that is used to create a phage display library expressing bacterial secreted and membrane bound proteins. This library is used to select displayed bacterial secretome proteins that interact with host immune components.
36 CFR § 1193.43 - Output, display, and control functions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... functions. § 1193.43 Section § 1193.43 Parks, Forests, and Public Property ARCHITECTURAL AND... Accessibility and Usability § 1193.43 Output, display, and control functions. All information necessary to... amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain...
Engineering M13 for phage display.
Sidhu, S S
2001-09-01
Phage display is achieved by fusing polypeptide libraries to phage coat proteins. The resulting phage particles display the polypeptides on their surfaces and they also contain the encoding DNA. Library members with particular functions can be isolated with simple selections and polypeptide sequences can be decoded from the encapsulated DNA. The technology's success depends on the efficiency with which polypeptides can be displayed on the phage surface, and significant progress has been made in engineering M13 bacteriophage coat proteins as improved phage display platforms. Functional display has been achieved with all five M13 coat proteins, with both N- and C-terminal fusions. Also, coat protein mutants have been designed and selected to improve the efficiency of heterologous protein display, and in the extreme case, completely artificial coat proteins have been evolved specifically as display platforms. These studies demonstrate that the M13 phage coat is extremely malleable, and this property can be used to engineer the phage particle specifically for phage display. These improvements expand the utility of phage display as a powerful tool in modern biotechnology.
Features and limitations of mobile tablet devices for viewing radiological images.
Grunert, J H
2015-03-01
Mobile radiological image display systems are becoming increasingly common, necessitating a comparison of the features of these systems, specifically the operating system employed, connection to stationary PACS, data security and rang of image display and image analysis functions. In the fall of 2013, a total of 17 PACS suppliers were surveyed regarding the technical features of 18 mobile radiological image display systems using a standardized questionnaire. The study also examined to what extent the technical specifications of the mobile image display systems satisfy the provisions of the Germany Medical Devices Act as well as the provisions of the German X-ray ordinance (RöV). There are clear differences in terms of how the mobile systems connected to the stationary PACS. Web-based solutions allow the mobile image display systems to function independently of their operating systems. The examined systems differed very little in terms of image display and image analysis functions. Mobile image display systems complement stationary PACS and can be used to view images. The impacts of the new quality assurance guidelines (QS-RL) as well as the upcoming new standard DIN 6868 - 157 on the acceptance testing of mobile image display units for the purpose of image evaluation are discussed. © Georg Thieme Verlag KG Stuttgart · New York.
Histological and transcriptomic effects of 17α-methyltestosterone on zebrafish gonad development.
Lee, Stephanie Ling Jie; Horsfield, Julia A; Black, Michael A; Rutherford, Kim; Fisher, Amanda; Gemmell, Neil J
2017-07-24
Sex hormones play important roles in teleost ovarian and testicular development. In zebrafish, ovarian differentiation appears to be dictated by an oocyte-derived signal via Cyp19a1a aromatase-mediated estrogen production. Androgens and aromatase inhibitors can induce female-to-male sex reversal, however, the mechanisms underlying gonadal masculinisation are poorly understood. We used histological analyses together with RNA sequencing to characterise zebrafish gonadal transcriptomes and investigate the effects of 17α-methyltestosterone on gonadal differentiation. At a morphological level, 17α-methyltestosterone (MT) masculinised gonads and accelerated spermatogenesis, and these changes were paralleled in masculinisation and de-feminisation of gonadal transcriptomes. MT treatment upregulated expression of genes involved in male sex determination and differentiation (amh, dmrt1, gsdf and wt1a) and those involved in 11-oxygenated androgen production (cyp11c1 and hsd11b2). It also repressed expression of ovarian development and folliculogenesis genes (bmp15, gdf9, figla, zp2.1 and zp3b). Furthermore, MT treatment altered epigenetic modification of histones in zebrafish gonads. Contrary to expectations, higher levels of cyp19a1a or foxl2 expression in control ovaries compared to MT-treated testes and control testes were not statistically significant during early gonad development (40 dpf). Our study suggests that both androgen production and aromatase inhibition are important for androgen-induced gonadal masculinisation and natural testicular differentiation in zebrafish.
Method and system for monitoring and displaying engine performance parameters
NASA Technical Reports Server (NTRS)
Abbott, Terence S. (Inventor); Person, Lee H., Jr. (Inventor)
1988-01-01
The invention is believed a major improvement that will have a broad application in governmental and commercial aviation. It provides a dynamic method and system for monitoring and simultaneously displaying in easily scanned form the available, predicted, and actual thrust of a jet aircraft engine under actual operating conditions. The available and predicted thrusts are based on the performance of a functional model of the aircraft engine under the same operating conditions. Other critical performance parameters of the aircraft engine and functional model are generated and compared, the differences in value being simultaneously displayed in conjunction with the displayed thrust values. Thus, the displayed information permits the pilot to make power adjustments directly while keeping him aware of total performance at a glance of a single display panel.
Scream-embrace displays in wild black-horned capuchin monkeys.
Lynch Alfaro, Jessica
2008-06-01
Reintroduction of capuchin monkeys (Cebus apella) into their social group in captivity can elicit sirena screams and embraces. Captive scream-embrace displays are male biased, and females never perform sirena screams. One hypothesis is that scream-embrace displays serve a tension-reduction or reconciliatory function between males with conflicting interests. Alternatively, these displays may function to maintain strong affiliative bonds between friendly male dyads. Scream and/or embrace displays in wild Brazilian black-horned capuchins were analyzed for social and ecological contexts, behavioral components, and individuals involved. Seventy-two displays were observed during the 199-day study period. Among the 66 displays for which both members could be identified by sex, there were 42 occurrences of male-male dyads, 17 of male-female dyads, and seven of female-female dyads. Scream-embrace dyads were male-male pairs significantly more often than expected from group membership, and the alpha male was the only male to engage in scream-embrace displays with females. Female-female pairs did embrace, but never emitted sirena screams. Displays most commonly occurred in "reunion" contexts, primarily the reuniting of subgroups after hours or days out of contact, but also after intergroup encounters, and across groups in "intergroup" displays. Displays were rare, but socially contagious, and subgroup reunions could elicit multiple displays in rapid succession. Although the occurrence of screams and embraces was positively correlated, both behaviors also occurred independently, and their functions may be different. Male sirena screams may be honest advertisements of united alliances, directed toward a third party, whereas the embrace may be a risky affiliative signal, directed primarily within the dyad. Copyright 2008 Wiley-Liss, Inc.
A Real-Time Phase Vector Display for EEG Monitoring
NASA Technical Reports Server (NTRS)
Finger, Herbert J.; Anliker, James E.; Rimmer, Tamara
1973-01-01
A real-time, computer-based, phase vector display system has been developed which will output a vector whose phase is equal to the delay between a trigger and the peak of a function which is quasi-coherent with respect to the trigger. The system also contains a sliding averager which enables the operator to average successive trials before calculating the phase vector. Data collection, averaging and display generation are performed on a LINC-8 computer. Output displays appear on several X-Y CRT display units and on a kymograph camera/oscilloscope unit which is used to generate photographs of time-varying phase vectors or contourograms of time-varying averages of input functions.
Multi-function displays : a guide for human factors evaluation.
DOT National Transportation Integrated Search
2013-11-01
This guide is designed to assist aircraft certification personnel and avionics : manufacturers in evaluating the human factors aspects of Multi-function Displays : (MFDs) for FAA certification. The guide focuses specifically on human factors and : do...
Software Verification of Orion Cockpit Displays
NASA Technical Reports Server (NTRS)
Biswas, M. A. Rafe; Garcia, Samuel; Prado, Matthew; Hossain, Sadad; Souris, Matthew; Morin, Lee
2017-01-01
NASA's latest spacecraft Orion is in the development process of taking humans deeper into space. Orion is equipped with three main displays to monitor and control the spacecraft. To ensure the software behind the glass displays operates without faults, rigorous testing is needed. To conduct such testing, the Rapid Prototyping Lab at NASA's Johnson Space Center along with the University of Texas at Tyler employed a software verification tool, EggPlant Functional by TestPlant. It is an image based test automation tool that allows users to create scripts to verify the functionality within a program. A set of edge key framework and Common EggPlant Functions were developed to enable creation of scripts in an efficient fashion. This framework standardized the way to code and to simulate user inputs in the verification process. Moreover, the Common EggPlant Functions can be used repeatedly in verification of different displays.
DOT National Transportation Integrated Search
2005-09-30
There is currently no common symbology standard for the electronic display of navigation information. The wide range of display technology and the different functions these displays support makes it difficult to design symbols that are easily recogni...
Hard copies for digital medical images: an overview
NASA Astrophysics Data System (ADS)
Blume, Hartwig R.; Muka, Edward
1995-04-01
This paper is a condensed version of an invited overview on the technology of film hard-copies used in radiology. Because the overview was given to an essentially nonmedical audience, the reliance on film hard-copies in radiology is outlined in greater detail. The overview is concerned with laser image recorders generating monochrome prints on silver-halide films. The basic components of laser image recorders are sketched. The paper concentrates on the physical parameters - characteristic function, dynamic range, digitization resolution, modulation transfer function, and noise power spectrum - which define image quality and information transfer capability of the printed image. A preliminary approach is presented to compare the printed image quality with noise in the acquired image as well as with the noise of state-of- the-art cathode-ray-tube display systems. High-performance laser-image- recorder/silver-halide-film/light-box systems are well capable of reproducing acquired radiologic information. Most recently development was begun toward a display function standard for soft-copy display systems to facilitate similarity of image presentation between different soft-copy displays as well as between soft- and hard-copy displays. The standard display function is based on perceptional linearization. The standard is briefly reviewed to encourage the printer industry to adopt it, too.
Displaying uncertainty: investigating the effects of display format and specificity.
Bisantz, Ann M; Marsiglio, Stephanie Schinzing; Munch, Jessica
2005-01-01
We conducted four studies regarding the representation of probabilistic information. Experiments 1 through 3 compared performance on a simulated stock purchase task, in which information regarding stock profitability was probabilistic. Two variables were manipulated: display format for probabilistic information (blurred and colored icons, linguistic phrases, numeric expressions, and combinations) and specificity level (in which the number and size of discrete steps into which the probabilistic information was mapped differed). Results indicated few performance differences attributable to display format; however, performance did improve with greater specificity. Experiment 4, in which participants generated membership functions corresponding to three display formats, found a high degree of similarity in functions across formats and participants and a strong relationship between the shape of the membership function and the intended meaning of the representation. These results indicate that participants can successfully interpret nonnumeric representations of uncertainty and can use such representations in a manner similar to the way numeric expressions are used in a decision-making task. Actual or potential applications of this research include the use of graphical representations of uncertainty in systems such as command and control and situation displays.
Survey of multi-function display and control technology
NASA Technical Reports Server (NTRS)
Spiger, R. J.; Farrell, R. J.; Tonkin, M. H.
1982-01-01
The NASA orbiter spacecraft incorporates a complex array of systems, displays and controls. The incorporation of discrete dedicated controls into a multi-function display and control system (MFDCS) offers the potential for savings in weight, power, panel space and crew training time. The technology applicable to the development of a MFDCS for orbiter application is surveyed. Technology thought to be applicable presently or in the next five years is highlighted. Areas discussed include display media, data handling and processing, controls and operator interactions and the human factors considerations which are involved in a MFDCS design. Several examples of applicable MFDCS technology are described.
Polychromatic plots: graphical display of multidimensional data.
Roederer, Mario; Moody, M Anthony
2008-09-01
Limitations of graphical displays as well as human perception make the presentation and analysis of multidimensional data challenging. Graphical display of information on paper or by current projectors is perforce limited to two dimensions; the encoding of information from other dimensions must be overloaded into the two physical dimensions. A number of alternative means of encoding this information have been implemented, such as offsetting data points at an angle (e.g., three-dimensional projections onto a two-dimensional surface) or generating derived parameters that are combinations of other variables (e.g., principal components). Here, we explore the use of color to encode additional dimensions of data. PolyChromatic Plots are standard dot plots, where the color of each event is defined by the values of one, two, or three of the measurements for that event. The measurements for these parameters are mapped onto an intensity value for each primary color (red, green, or blue) based on different functions. In addition, differential weighting of the priority with which overlapping events are displayed can be defined by these same measurements. PolyChromatic Plots can encode up to five independent dimensions of data in a single display. By altering the color mapping function and the priority function, very different displays that highlight or de-emphasize populations of events can be generated. As for standard black-and-white dot plots, frequency information can be significantly biased by this display; care must be taken to ensure appropriate interpretation of the displays. PolyChromatic Plots are a powerful display type that enables rapid data exploration. By virtue of encoding as many as five dimensions of data independently, an enormous amount of information can be gleaned from the displays. In many ways, the display performs somewhat like an unsupervised cluster algorithm, by highlighting events of similar distributions in multivariate space.
Apollo experience report: Crew station integration. Volume 2: Crew station displays and controls
NASA Technical Reports Server (NTRS)
Langdoc, W. A.; Nassman, D. A.
1975-01-01
The functional requirements for the Apollo displays and controls system are presented. The configuration of the displays, controls, and panels for both the command module and the lunar module are described, and the design development and operational experience of the displays and controls system are discussed. Pertinent recommendations for future displays and controls system design efforts are made.
Method and apparatus for an optical function generator for seamless tiled displays
NASA Technical Reports Server (NTRS)
Johnson, Michael (Inventor); Chen, Chung-Jen (Inventor)
2004-01-01
Producing seamless tiled images from multiple displays includes measuring a luminance profile of each of the displays, computing a desired luminance profile for each of the displays, and determining a spatial gradient profile of each of the displays based on the measured luminance profile and the computed desired luminance profile. The determined spatial gradient profile is applied to a spatial filter to be inserted into each of the displays to produce the seamless tiled display image.
NASA Technical Reports Server (NTRS)
Hibbard, William L.; Dyer, Charles R.; Paul, Brian E.
1994-01-01
The VIS-AD data model integrates metadata about the precision of values, including missing data indicators and the way that arrays sample continuous functions, with the data objects of a scientific programming language. The data objects of this data model form a lattice, ordered by the precision with which they approximate mathematical objects. We define a similar lattice of displays and study visualization processes as functions from data lattices to display lattices. Such functions can be applied to visualize data objects of all data types and are thus polymorphic.
Computer Graphics in Research: Some State -of-the-Art Systems
ERIC Educational Resources Information Center
Reddy, R.; And Others
1975-01-01
A description is given of the structure and functional characteristics of three types of interactive computer graphic systems, developed by the Department of Computer Science at Carnegie-Mellon; a high-speed programmable display capable of displaying 50,000 short vectors, flicker free; a shaded-color video display for the display of gray-scale…
Laser Optometric Assessment Of Visual Display Viewability
NASA Astrophysics Data System (ADS)
Murch, Gerald M.
1983-08-01
Through the technique of laser optometry, measurements of a display user's visual accommodation and binocular convergence were used to assess the visual impact of display color, technology, contrast, and work time. The studies reported here indicate the potential of visual-function measurements as an objective means of improving the design of visual displays.
A novel helper phage for HaloTag-mediated co-display of enzyme and substrate on phage.
Delespaul, Wouter; Peeters, Yves; Herdewijn, Piet; Robben, Johan
2015-05-01
Phage display is an established technique for the molecular evolution of peptides and proteins. For the selection of enzymes based on catalytic activity however, simultaneous coupling of an enzyme and its substrate to the phage surface is required. To facilitate this process of co-display, we developed a new helper phage displaying HaloTag, a modified haloalkane dehalogenase that binds specifically and covalently to functionalized haloalkane ligands. The display of functional HaloTag was demonstrated by capture on streptavidin-coated magnetic beads, after coupling a biotinylated haloalkane ligand, or after on-phage extension of a DNA oligonucleotide primer with a biotinylated nucleotide by phi29 DNA polymerase. We also achieved co-display of HaloTag and phi29 DNA polymerase, thereby opening perspectives for the molecular evolution of this enzyme (and others) towards new substrate specificities. Copyright © 2015 Elsevier Inc. All rights reserved.
Cell-surface display of enzymes by the yeast Saccharomyces cerevisiae for synthetic biology.
Tanaka, Tsutomu; Kondo, Akihiko
2015-02-01
In yeast cell-surface displays, functional proteins, such as cellulases, are genetically fused to an anchor protein and expressed on the cell surface. Saccharomyces cerevisiae, which is often utilized as a cell factory for the production of fuels, chemicals, and proteins, is the most commonly used yeast for cell-surface display. To construct yeast cells with a desired function, such as the ability to utilize cellulose as a substrate for bioethanol production, cell-surface display techniques for the efficient expression of enzymes on the cell membrane need to be combined with metabolic engineering approaches for manipulating target pathways within cells. In this Minireview, we summarize the recent progress of biorefinery fields in the development and application of yeast cell-surface displays from a synthetic biology perspective and discuss approaches for further enhancing cell-surface display efficiency. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permission@oup.com.
The Formal Specification of a Visual display Device: Design and Implementation.
1985-06-01
The use of these data structures with their defined operations, give the programmer a very powerful instructions set. Like the DPU code generator in...which any AM hosted machine could faithfully display. 27 In- general , most applications have no need to create images from a data structure representing...formation of standard functional interfaces to these resources. OS’s generally do not provide a functional interface to either the processor or the display2
Biochemical functionalization of peptide nanotubes with phage displayed peptides
NASA Astrophysics Data System (ADS)
Swaminathan, Swathi; Cui, Yue
2016-09-01
The development of a general approach for the biochemical functionalization of peptide nanotubes (PNTs) could open up existing opportunities in both fundamental studies as well as a variety of applications. PNTs are spontaneously assembled organic nanostructures made from peptides. Phage display has emerged as a powerful approach for identifying selective peptide binding motifs. Here, we demonstrate for the first time the biochemical functionalization of PNTs via peptides identified from a phage display peptide library. The phage-displayed peptides are shown to recognize PNTs. These advances further allow for the development of bifunctional peptides for the capture of bacteria and the self-assembly of silver particles onto PNTs. We anticipate that these results could provide significant opportunities for using PNTs in both fundamental studies and practical applications, including sensors and biosensors nanoelectronics, energy storage devices, drug delivery, and tissue engineering.
Exponential localization of Wannier functions in insulators.
Brouder, Christian; Panati, Gianluca; Calandra, Matteo; Mourougane, Christophe; Marzari, Nicola
2007-01-26
The exponential localization of Wannier functions in two or three dimensions is proven for all insulators that display time-reversal symmetry, settling a long-standing conjecture. Our proof relies on the equivalence between the existence of analytic quasi-Bloch functions and the nullity of the Chern numbers (or of the Hall current) for the system under consideration. The same equivalence implies that Chern insulators cannot display exponentially localized Wannier functions. An explicit condition for the reality of the Wannier functions is identified.
Otey, Christopher R; Silberg, Jonathan J; Voigt, Christopher A; Endelman, Jeffrey B; Bandara, Geethani; Arnold, Frances H
2004-03-01
Recombination generates chimeric proteins whose ability to fold depends on minimizing structural perturbations that result when portions of the sequence are inherited from different parents. These chimeric sequences can display functional properties characteristic of the parents or acquire entirely new functions. Seventeen chimeras were generated from two CYP102 members of the functionally diverse cytochrome p450 family. Chimeras predicted to have limited structural disruption, as defined by the SCHEMA algorithm, displayed CO binding spectra characteristic of folded p450s. Even this small population exhibited significant functional diversity: chimeras displayed altered substrate specificities, a wide range in thermostabilities, up to a 40-fold increase in peroxidase activity, and ability to hydroxylate a substrate toward which neither parent heme domain shows detectable activity. These results suggest that SCHEMA-guided recombination can be used to generate diverse p450s for exploring function evolution within the p450 structural framework.
NASA Astrophysics Data System (ADS)
Ferreira, Flávio P.; Forte, Paulo M. F.; Felgueiras, Paulo E. R.; Bret, Boris P. J.; Belsley, Michael S.; Nunes-Pereira, Eduardo J.
2017-02-01
An Automatic Optical Inspection (AOI) system for optical inspection of imaging devices used in automotive industry using an inspecting optics of lower spatial resolution than the device under inspection is described. This system is robust and with no moving parts. The cycle time is small. Its main advantage is that it is capable of detecting and quantifying defects in regular patterns, working below the Shannon-Nyquist criterion for optical resolution, using a single low resolution image sensor. It is easily scalable, which is an important advantage in industrial applications, since the same inspecting sensor can be reused for increasingly higher spatial resolutions of the devices to be inspected. The optical inspection is implemented with a notch multi-band Fourier filter, making the procedure especially fitted for regular patterns, like the ones that can be produced in image displays and Head Up Displays (HUDs). The regular patterns are used in production line only, for inspection purposes. For image displays, functional defects are detected at the level of a sub-image display grid element unit. Functional defects are the ones impairing the function of the display, and are preferred in AOI to the direct geometric imaging, since those are the ones directly related with the end-user experience. The shift in emphasis from geometric imaging to functional imaging is critical, since it is this that allows quantitative inspection, below Shannon-Nyquist. For HUDs, the functional detect detection addresses defects resulting from the combined effect of the image display and the image forming optics.
Active learning in optics and photonics: Liquid Crystal Display in the do-it-yourself
NASA Astrophysics Data System (ADS)
Vauderwange, Oliver; Haiss, Ulrich; Wozniak, Peter; Israel, Kai; Curticapean, Dan
2015-10-01
Monitors are in the center of media productions and hold an important function as the main visual interface. Tablets and smartphones are becoming more and more important work tools in the media industry. As an extension to our lecture contents an intensive discussion of different display technologies and its applications is taking place now. The established LCD (Liquid Crystal Display) technology and the promising OLED (Organic Light Emitting Diode) technology are in the focus. The classic LCD is currently the most important display technology. The paper will present how the students should develop sense for display technologies besides the theoretical scientific basics. The workshop focuses increasingly on the technical aspects of the display technology and has the goal of deepening the students understanding of the functionality by building simple Liquid Crystal Displays by themselves. The authors will present their experience in the field of display technologies. A mixture of theoretical and practical lectures has the goal of a deeper understanding in the field of digital color representation and display technologies. The design and development of a suitable learning environment with the required infrastructure is crucial. The main focus of this paper is on the hands-on optics workshop "Liquid Crystal Display in the do-it-yourself".
Kim, Hee Jin; Cha, Jungho; Lee, Jong-Min; Shin, Ji Soo; Jung, Na-Yeon; Kim, Yeo Jin; Choe, Yearn Seong; Lee, Kyung Han; Kim, Sung Tae; Kim, Jae Seung; Lee, Jae Hong; Na, Duk L; Seo, Sang Won
2016-01-01
Recent advances in resting-state functional MRI have revealed altered functional networks in Alzheimer's disease (AD), especially those of the default mode network (DMN) and central executive network (CEN). However, few studies have evaluated whether small vessel disease (SVD) or combined amyloid and SVD burdens affect the DMN or CEN. The aim of this study was to evaluate whether SVD or combined amyloid and SVD burdens affect the DMN or CEN. In this cross-sectional study, we investigated the resting-state functional connectivity within DMN and CEN in 37 Pittsburgh compound-B (PiB)(+) AD, 37 PiB(-) subcortical vascular dementia (SVaD), 13 mixed dementia patients, and 65 normal controls. When the resting-state DMN of PiB(+) AD and PiB(-) SVaD patients were compared, the PiB(+) AD patients displayed lower functional connectivity in the inferior parietal lobule while the PiB(-) SVaD patients displayed lower functional connectivity in the medial frontal and superior frontal gyri. Compared to the PiB(-) SVaD or PiB(+) AD, the mixed dementia patients displayed lower functional connectivity within the DMN in the posterior cingulate gyrus. When the resting-state CEN connectivity of PiB(+) AD and PiB(-) SVaD patients were compared, the PiB(-) SVaD patients displayed lower functional connectivity in the anterior insular region. Compared to the PiB(-) SVaD or PiB(+) AD, the mixed dementia patients displayed lower functional connectivity within the CEN in the inferior frontal gyrus. Our findings suggest that in PiB(+) AD and PiB(-) SVaD, there is divergent disruptions in resting-state DMN and CEN. Furthermore, patients with combined amyloid and SVD burdens exhibited more disrupted resting-state DMN and CEN than patients with only amyloid or SVD burden.
Phage as a template to grow bone mineral nanocrystals.
Cao, Binrui; Xu, Hong; Mao, Chuanbin
2014-01-01
Phage display is a biotechnique that fuses functional peptides on the outer surface of filamentous phage by inserting DNA encoding the peptides into the genes of its coat proteins. The resultant peptide-displayed phage particles have been widely used as biotemplates for the synthesis of functional hybrid nanomaterials. Here, we describe the bioengineering of M13 filamentous phage to surface-display bone mineral (hydroxyapatite (HAP))-nucleating peptides derived from dentin matrix protein-1 and using the engineered phage as a biotemplate to grow HAP nanocrystals.
Evaluation of graphic cardiovascular display in a high-fidelity simulator.
Agutter, James; Drews, Frank; Syroid, Noah; Westneskow, Dwayne; Albert, Rob; Strayer, David; Bermudez, Julio; Weinger, Matthew B
2003-11-01
"Human error" in anesthesia can be attributed to misleading information from patient monitors or to the physician's failure to recognize a pattern. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. We designed a graphic display to show hemodynamic variables. Twenty anesthesiologists were asked to assume care of a simulated patient. Half the participants used the graphic cardiovascular display; the other half used a Datex As/3 monitor. One scenario was a total hip replacement with a transfusion reaction to mismatched blood. The second scenario was a radical prostatectomy with 1.5 L of blood loss and myocardial ischemia. Subjects who used the graphic display detected myocardial ischemia 2 min sooner than those who did not use the display. Treatment was initiated sooner (2.5 versus 4.9 min). There were no significant differences between groups in the hip replacement scenario. Systolic blood pressure deviated less from baseline, central venous pressure was closer to its baseline, and arterial oxygen saturation was higher at the end of the case when the graphic display was used. The study lends some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnose, manage, and treat critical cardiovascular events in a simulated environment. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. A user-centered design process led to a novel object-oriented graphic display of hemodynamic variables containing emergent features and functional relationships. In a simulated environment, this display appeared to support clinicians' ability to diagnose, manage, and treat a critical cardiovascular event in a simulated environment. We designed a graphic display to show hemodynamic variables. The study provides some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnosis, mange, and treat critical cardiovascular events in a simulated environment.
Language Display: Authenticating Claims to Social Identity.
ERIC Educational Resources Information Center
Eastman, Carol M.; Stein, Roberta F.
1993-01-01
Discusses "language display," a language use strategy whereby members of one group lay claims to attributes associated with another, conveying messages of social, professional, ethnic identity. Examples from academia, politics, business, and advertising reveal language display functions as artifact of crossing linguistic boundaries…
Accelerometer Method and Apparatus for Integral Display and Control Functions
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1996-01-01
Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. Art accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.
Accelerometer Method and Apparatus for Integral Display and Control Functions
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1998-01-01
Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto is discussed. An accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.
Tao, Wenjing; Sun, Lina; Shi, Hongjuan; Cheng, Yunying; Jiang, Dongneng; Fu, Beide; Conte, Matthew A; Gammerdinger, William J; Kocher, Thomas D; Wang, Deshou
2016-05-04
MicroRNAs (miRNAs) represent a second regulatory network that has important effects on gene expression and protein translation during biological process. However, the possible role of miRNAs in the early stages of fish sex differentiation is not well understood. In this study, we carried an integrated analysis of miRNA and mRNA expression profiles to explore their possibly regulatory patterns at the critical stage of sex differentiation in tilapia. We identified 279 pre-miRNA genes in tilapia genome, which were highly conserved in other fish species. Based on small RNA library sequencing, we identified 635 mature miRNAs in tilapia gonads, in which 62 and 49 miRNAs showed higher expression in XX and XY gonads, respectively. The predicted targets of these sex-biased miRNAs (e.g., miR-9, miR-21, miR-30a, miR-96, miR-200b, miR-212 and miR-7977) included genes encoding key enzymes in steroidogenic pathways (Cyp11a1, Hsd3b, Cyp19a1a, Hsd11b) and key molecules involved in vertebrate sex differentiation (Foxl2, Amh, Star1, Sf1, Dmrt1, and Gsdf). These genes also showed sex-biased expression in tilapia gonads at 5 dah. Some miRNAs (e.g., miR-96 and miR-737) targeted multiple genes involved in steroid synthesis, suggesting a complex miRNA regulatory network during early sex differentiation in this fish. The sequence and expression patterns of most miRNAs in tilapia are conserved in fishes, indicating the basic functions of vertebrate miRNAs might share a common evolutionary origin. This comprehensive analysis of miRNA and mRNA at the early stage of molecular sex differentiation in tilapia XX and XY gonads lead to the discovery of differentially expressed miRNAs and their putative targets, which will facilitate studies of the regulatory network of molecular sex determination and differentiation in fishes.
Therapeutic Antibodies by Phage Display.
Shim, Hyunbo
2016-01-01
Antibody phage display is a major technological platform for the generation of fully human antibodies for therapeutic purposes. The in vitro binder selection by phage display allows researchers to have more extensive control over binding parameters and facilitates the isolation of clinical candidate antibodies with desired binding and/or functional profiles. Since the invention of antibody phage display in late 1980s, significant technological advancements in the design, construction, and selection of the antibody libraries have been made, and several fully human antibodies generated by phage display are currently approved or in various clinical development stages. In this review, the background and details of antibody phage display technology, and representative antibody libraries with natural or synthetic sequence diversity and different construction strategies are described. The generation, optimization, functional and biophysical properties, and preclinical and clinical developments of some of the phage display-derived therapeutic antibodies approved for use in patients or in late-stage clinical trials are also discussed. With evolving novel disease targets and therapeutic strategies, antibody phage display is expected to continue to play a central role in the development of the next generation of therapeutic antibodies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Accelerometer method and apparatus for integral display and control functions
NASA Astrophysics Data System (ADS)
Bozeman, Richard J., Jr.
1992-06-01
Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.
Accelerometer method and apparatus for integral display and control functions
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1992-01-01
Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.
Data synthesis and display programs for wave distribution function analysis
NASA Technical Reports Server (NTRS)
Storey, L. R. O.; Yeh, K. J.
1992-01-01
At the National Space Science Data Center (NSSDC) software was written to synthesize and display artificial data for use in developing the methodology of wave distribution analysis. The software comprises two separate interactive programs, one for data synthesis and the other for data display.
Head Up Displays. (Latest Citations from the Aerospace Database)
NASA Technical Reports Server (NTRS)
1997-01-01
The bibliography contains citations concerning the design, fabrication, and applications of head up displays (HUDs). Applications include military aircraft, helicopters, space shuttle, and commercial aircraft. Functions of the display include instrument approach, target tracking, and navigation. The head up display provides for an integrated avionics system with the pilot in the loop. (Contains 50-250 citations and includes a subject term index and title list.)
Head Up Displays. (Latest citations from the Aerospace Database)
NASA Technical Reports Server (NTRS)
1996-01-01
The bibliography contains citations concerning the design, fabrication, and applications of head up displays (HUDs). Applications include military aircraft, helicopters, space shuttle, and commercial aircraft. Functions of the display include instrument approach, target tracking, and navigation. The head up display provides for an integrated avionics system with the pilot in the loop. (Contains 50-250 citations and includes a subject term index and title list.)
Lanctot, Richard B.; Sandercock, B.K.; Kempenaers, Bart
2000-01-01
Many shorebirds show elaborate breeding displays that include aerial flights and ground displays accompanied by song. The mate attraction hypothesis suggests that breeding displays function to attract mates and maintain pair bonds, whereas the territory defense hypothesis suggests breeding displays function in defining and defending nesting and feeding territories. We tested these hypotheses in the Western Sandpiper (Calidris mauri) by contrasting the duration and level of male breeding displays among pairs that differed in their mate and site fidelity. As predicted by the mate attraction hypothesis, males performed the highest number of song sequences during pair formation, and males paired with their mate of a prior year sang less than males paired to new mates. Further, sitefaithful males mated to a new but experienced mate displayed significantly more than remated males or males new to the area. This suggests a male's prior familiarity with an area and his neighbors does not lessen his display rate as was predicted under the territory defense hypothesis. Limited support for the territory defense hypothesis came from observations of males performing breeding displays with neighboring males along nest territory boundaries. This behavior was short-lived, however, as males abandoned nesting areas after pair-formation and used adjacent or disjointed feeding areas during egg-laying and incubation. Male aggression (i.e., aerial and ground chases), as opposed to breeding displays, appeared to be the principal means of maintaining territory boundaries. Indeed, the rate at which males chased other males remained fairly constant and high throughout the breeding season. Male chasing behavior may also serve as a paternity guard to protect against extra-pair copulations. Our study also found that a female's prior breeding experience in an area correlated with a reduced display rate by her mate, particularly if that mate was new to the area. This indicates female characteristics may not only drive nest initiation, as has been shown in other studies, but are important in determining the duration and extent of male display.
Holographic and light-field imaging for augmented reality
NASA Astrophysics Data System (ADS)
Lee, Byoungho; Hong, Jong-Young; Jang, Changwon; Jeong, Jinsoo; Lee, Chang-Kun
2017-02-01
We discuss on the recent state of the augmented reality (AR) display technology. In order to realize AR, various seethrough three-dimensional (3D) display techniques have been reported. We describe the AR display with 3D functionality such as light-field display and holography. See-through light-field display can be categorized by the optical elements which are used for see-through property: optical elements controlling path of the light-fields and those generating see-through light-field. Holographic display can be also a good candidate for AR display because it can reconstruct wavefront information and provide realistic virtual information. We introduce the see-through holographic display using various optical techniques.
1983-08-01
AD- R136 99 THE INTEGRATED MISSION-PLNNING STATION: FUNCTIONAL 1/3 REQUIREMENTS AVIATOR-..(U) RNACAPR SCIENCES INC SANTA BARBARA CA S P ROGERS RUG...Continue on reverse side o necess.ar and identify by btock number) Interactive Systems Aviation Control-Display Functional Require- Plan-Computer...Dialogue Avionics Systems ments Map Display Army Aviation Design Criteria Helicopters M4ission Planning Cartography Digital Map Human Factors Navigation
Biological Templating and the Production of Functional Fibers
2006-11-01
technique to express designed functional peptides on the virus surface is so-called phage display . It has been widely used to modify the virus surface...and functionality. By using the phage display technique, short peptides containing 2 to 12 random amino acids can be fused into pIII proteins to... M13 filamentous bacteriophage were spun into continuous microfibers. These fibers can be made out of pure phage solution or a blended solution of
Kirkness, Catherine J; Burr, Robert L; Cain, Kevin C; Newell, David W; Mitchell, Pamela H
2008-01-01
Nurses' ability to rapidly detect decreases in cerebral perfusion pressure (CPP), which may contribute to secondary brain injury, may be limited by poor visibility of CPP displays. To evaluate the impact of a highly visible CPP display on the functional outcome in individuals with cerebral aneurysms. Patients with cerebral aneurysms (n = 100) who underwent continuous CPP monitoring were enrolled and randomized to beds with or without the additional CPP display. Six-month outcome was assessed. Functional outcome was not significantly different between control and intervention groups after controlling for initial neurologic condition (odds ratio .904, 95% confidence interval 0.317 to 2.573). However, greater time below CPP thresholds (55 to 70 mm Hg) was significantly associated with poorer outcome (P = .005 to .010). Although the enhanced CPP display was not associated with significantly better outcome, longer periods of CPP below set levels were associated with poorer outcome.
White constancy method for mobile displays
NASA Astrophysics Data System (ADS)
Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo
2014-03-01
In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.
Young Children's Responses to Guilt Displays
ERIC Educational Resources Information Center
Vaish, Amrisha; Carpenter, Malinda; Tomasello, Michael
2011-01-01
Displaying guilt after a transgression serves to appease the victim and other group members, restore interpersonal relationships, and indicate the transgressors' awareness of and desire to conform to the group's norms. We investigated whether and when young children are sensitive to these functions of guilt displays. In Study 1, after 4- and…
Design and Development of Functionally Effective Human-Machine Interfaces for Firing Room Displays
NASA Technical Reports Server (NTRS)
Cho, Henry
2013-01-01
This project involves creating software for support equipment used on the Space Launch System (SLS). The goal is to create applications and displays that will be used to remotely operate equipment from the firing room and will continue to support the SLS launch vehicle to the extent of its program. These displays include design practices that help to convey information effectively, such as minimizing distractions at normal operating state and displaying intentional distractions during a warning or alarm state. The general practice for creating an operator display is to reduce the detail of unimportant aspects of the display and promote focus on data and dynamic information. These practices include using minimalist design, using muted tones for background colors, using a standard font at a readable text size, displaying alarms visible for immediate attention, grouping data logically, and displaying data appropriately varying on the type of data. Users of these displays are more likely to stay focused on operating for longer periods by using design practices that reduce eye strain and fatigue. Effective operator displays will improve safety by reducing human errors during operation, which will help prevent catastrophic accidents. This report entails the details of my work on developing remote displays for the Hypergolic fuel servicing system. Before developing a prototype display, the design and requirements of the system are outlined and compiled into a document. Then each subsystem has schematic representations drawn that meet the specifications detailed in the document. The schematics are then used as the outline to create display representations of each subsystem. Each display is first tested individually. Then the displays are integrated with a prototype of the master system, and they are tested in a simulated environment then retested in the real environment. Extensive testing is important to ensure the displays function reliably as intended.
Design and Development of Functionally Effective Human-Machine Interfaces for Firing Room Displays
NASA Technical Reports Server (NTRS)
Cho, Henry
2013-01-01
This project involves creating software for support equipment used on the Space l aunch System (SLS). The goal is to create applications and displays that will be used to remotely operate equipment from the firing room and will continue to support the SLS launch vehicle to the extent of its program. These displays include design practices that help to convey information effectively, such as minimizing distractions at normal operating state and displaying intentional distractions during a warning or alarm state. The general practice for creating an operator display is to reduce the detail of unimportant aspects of the display and promote focus on data and dynamic information. These practices include using minimalist design, using muted tones for background colors, using a standard font at a readable text size, displaying alarms visible for Immediate attention, grouping data logically, and displaying data appropriately varying on the type of data. Users of these displays are more likely to stay focused on operating for longer periods by using design practices that reduce eye strain and fatigue. Effective operator displays will improve safety by reducing human errors during operation, which will help prevent catastrophic accidents. This report entails the details of my work on developing remote displays for the Hypergolics ground system. Before developing a prototype display, the design and requirements of the system are outlined and compiled into a document. Then each subsystem has schematic representations drawn tha.t meet the specifications detailed in the document. The schematics are then used as the outline to create display representations of each subsystem. Each display is first tested individually. Then the displays are integrated with a prototype of the master system, and they are tested in a simulated environment then retested in the real environment. Extensive testing is important to ensure the displays function reliably as intended.
Versatile microbial surface-display for environmental remediation and biofuels production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Cindy H.; Mulchandani, Ashok; Chen, wilfred
2008-02-14
Surface display is a powerful technique that utilizes natural microbial functional components to express proteins or peptides on the cell exterior. Since the reporting of the first surface-display system in the mid-1980s, a variety of new systems have been reported for yeast, Gram-positive and Gram-negative bacteria. Non-conventional display methods are emerging, eliminating the generation of genetically modified microorganisms. Cells with surface display are used as biocatalysts, biosorbents and biostimulants. Microbial cell-surface display has proven to be extremely important for numerous applications ranging from combinatorial library screening and protein engineering to bioremediation and biofuels production.
Kaufmann, William K.; Nevis, Kathleen R.; Qu, Pingping; Ibrahim, Joseph G.; Zhou, Tong; Zhou, Yingchun; Simpson, Dennis A.; Helms-Deaton, Jennifer; Cordeiro-Stone, Marila; Moore, Dominic T.; Thomas, Nancy E.; Hao, Honglin; Liu, Zhi; Shields, Janiel M.; Scott, Glynis A.; Sharpless, Norman E.
2009-01-01
Defects in DNA damage responses may underlie genetic instability and malignant progression in melanoma. Cultures of normal human melanocytes (NHMs) and melanoma lines were analyzed to determine whether global patterns of gene expression could predict the efficacy of DNA damage cell cycle checkpoints that arrest growth and suppress genetic instability. NHMs displayed effective G1 and G2 checkpoint responses to ionizing radiation-induced DNA damage. A majority of melanoma cell lines (11/16) displayed significant quantitative defects in one or both checkpoints. Melanomas with B-RAF mutations as a class displayed a significant defect in DNA damage G2 checkpoint function. In contrast the epithelial-like subtype of melanomas with wild-type N-RAS and B-RAF alleles displayed an effective G2 checkpoint but a significant defect in G1 checkpoint function. RNA expression profiling revealed that melanoma lines with defects in the DNA damage G1 checkpoint displayed reduced expression of p53 transcriptional targets, such as CDKN1A and DDB2, and enhanced expression of proliferation-associated genes, such as CDC7 and GEMININ. A Bayesian analysis tool was more accurate than significance analysis of microarrays for predicting checkpoint function using a leave-one-out method. The results suggest that defects in DNA damage checkpoints may be recognized in melanomas through analysis of gene expression. PMID:17597816
NASA Astrophysics Data System (ADS)
Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott
2017-09-01
We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.
Method and apparatus for calibrating a display using an array of cameras
NASA Technical Reports Server (NTRS)
Johnson, Michael J. (Inventor); Chen, Chung-Jen (Inventor); Chandrasekhar, Rajesh (Inventor)
2001-01-01
The present invention overcomes many of the disadvantages of the prior art by providing a display that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, the present invention provides one or more cameras to capture an image that is projected on a display screen. In one embodiment, the one or more cameras are placed on the same side of the screen as the projectors. In another embodiment, an array of cameras is provided on either or both sides of the screen for capturing a number of adjacent and/or overlapping capture images of the screen. In either of these embodiments, the resulting capture images are processed to identify any non-desirable characteristics including any visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and/or other visible artifacts.
A database system to support image algorithm evaluation
NASA Technical Reports Server (NTRS)
Lien, Y. E.
1977-01-01
The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.
Rajaram, Kaushik; Losada-Pérez, Patricia; Vermeeren, Veronique; Hosseinkhani, Baharak; Wagner, Patrick; Somers, Veerle; Michiels, Luc
2015-01-01
Over the last three decades, phage display technology has been used for the display of target-specific biomarkers, peptides, antibodies, etc. Phage display-based assays are mostly limited to the phage ELISA, which is notorious for its high background signal and laborious methodology. These problems have been recently overcome by designing a dual-display phage with two different end functionalities, namely, streptavidin (STV)-binding protein at one end and a rheumatoid arthritis-specific autoantigenic target at the other end. Using this dual-display phage, a much higher sensitivity in screening specificities of autoantibodies in complex serum sample has been detected compared to single-display phage system on phage ELISA. Herein, we aimed to develop a novel, rapid, and sensitive dual-display phage to detect autoantibodies presence in serum samples using quartz crystal microbalance with dissipation monitoring as a sensing platform. The vertical functionalization of the phage over the STV-modified surfaces resulted in clear frequency and dissipation shifts revealing a well-defined viscoelastic signature. Screening for autoantibodies using antihuman IgG-modified surfaces and the dual-display phage with STV magnetic bead complexes allowed to isolate the target entities from complex mixtures and to achieve a large response as compared to negative control samples. This novel dual-display strategy can be a potential alternative to the time consuming phage ELISA protocols for the qualitative analysis of serum autoantibodies and can be taken as a departure point to ultimately achieve a point of care diagnostic system.
Effect of protein properties on display efficiency using the M13 phage display system.
Imai, S; Mukai, Y; Takeda, T; Abe, Y; Nagano, K; Kamada, H; Nakagawa, S; Tsunoda, S; Tsutsumi, Y
2008-10-01
The M13 phage display system is a powerful technology for engineering proteins such as functional mutant proteins and peptides. In this system, it is necessary that the protein is displayed on the phage surface. Therefore, its application is often limited when a protein is poorly displayed. In this study, we attempted to understand the relationship between a protein's properties and its display efficiency using the well-known pIII and pVIII type phage display system. The display of positively charged SV40 NLS and HIV-1 Tat peptides on pill was less efficient than that of the neutrally charged RGDS peptide. When different molecular weight proteins (1.5-58 kDa) were displayed on pIII and pVIII, their display efficiencies were directly influenced by their molecular weights. These results indicate the usefulness in predicting a desired protein's compatibility with protein and peptide engineering using the phage display system.
Image quality evaluation of medical color and monochrome displays using an imaging colorimeter
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Gu, Xiliang; Fan, Jiahua
2012-10-01
The purpose of this presentation is to demonstrate the means which permit examining the accuracy of Image Quality with respect to MTF (Modulation Transfer Function) and NPS (Noise Power Spectrum) of Color Displays and Monochrome Displays. Indications were in the past that color displays could affect the clinical performance of color displays negatively compared to monochrome displays. Now colorimeters like the PM-1423 are available which have higher sensitivity and color accuracy than the traditional cameras like CCD cameras. Reference (1) was not based on measurements made with a colorimeter. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future SPIE Conference.Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future Annual SPIE Conference. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. The Imaging Colorimeter. Measurement of color image quality needs were done with an imaging colorimeter as it is shown below. Imaging colorimetry is ideally suited to FPD measurement because imaging systems capture spatial data generating millions of data points in a single measurement operation. The imaging colorimeter which was used was the PM-1423 from Radiant Imaging. It uses full-frame CCDs with 100% fill factor which makes it very suitable to measure luminance and chrominance of individual LCD pixels and sub-pixels on an LCD display. The CCDs used are 14-bit thermoelectrically cooled and temperature stabilized , scientific grade.
NASA Astrophysics Data System (ADS)
Schiefele, Jens; Bader, Joachim; Kastner, S.; Wiesemann, Thorsten; von Viebahn, Harro
2002-07-01
Next generation of cockpit display systems will display mass data. Mass data includes terrain, obstacle, and airport databases. Display formats will be two and eventually 3D. A prerequisite for the introduction of these new functions is the availability of certified graphics hardware. The paper describes functionality and required features of an aviation certified 2D/3D graphics board. This graphics board should be based on low-level and hi-level API calls. These graphic calls should be very similar to OpenGL. All software and the API must be aviation certified. As an example application, a 2D airport navigation function and a 3D terrain visualization is presented. The airport navigation format is based on highly precise airport database following EUROCAE ED-99/RTCA DO-272 specifications. Terrain resolution is based on EUROCAE ED-98/RTCA DO-276 requirements.
Integrated cockpit display and processor: the best solution for Link-16 applications
NASA Astrophysics Data System (ADS)
Smeyne, Alan L.; Savaya, John
2000-08-01
Link-16 Data Link systems are being added to current avionics systems to provide increased situational awareness and command data. By using a single intelligent display system, the impact to existing aircraft systems to implement Link-16 capabilities is minimized. Litton Guidance & Control Systems (G&CS), a military avionics supplier for more than forty years, provides Open System Architecture (OSA), large screen aircraft display systems. Based on a common set of plug-in modules, these Smart Multi-Function Displays (SMFD) are available in a variety of sizes and processing capabilities, any one of which can meet the Link-16 requirements. Using a single smart SMFD connected to a Link-16 subsystem has many advantages. With digital moving map capability, the SMFD can monitor and display air and ground tracks of both friendly and hostile forces while providing potential threat data to the operator. The SMFD can also monitor vehicle status and mission data to share between friendly air and surface forces. To support the integrated digital battlefield, Link-16 capability is required and the Litton G&CS SMFD provides the processing/display functionality to implement this capability.
Psychophysical contrast calibration
To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli
2013-01-01
Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843
ERIC Educational Resources Information Center
Kurtz, Patricia F.; Boelter, Eric W.; Jarmolowicz, David P.; Chin, Michelle D.; Hagopian, Louis P.
2011-01-01
This paper examines the literature on the use of functional communication training (FCT) as a treatment for problem behavior displayed by individuals with intellectual disabilities (ID). Criteria for empirically supported treatments developed by Divisions 12 and 16 of the American Psychological Association (Kratochwill & Stoiber, 2002; Task Force,…
USDA-ARS?s Scientific Manuscript database
The objective of this study was to evaluate effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg meat during display storage. Two hundred and forty 1-day-old male chicks (5 bird per pen) were randomly subjected to four treatments...
LMDS Lightweight Modular Display System.
1982-02-16
based on standard functions. This means that the cost to produce a particular display function can be met in the most economical fashion and at the same...not mean that the NTDS interface would be eliminated. What is anticipated is the use of ETHERNET at a low level of system interface, ie internal to...GENERATOR dSYMBOL GEN eCOMMUNICATION 3-2 The architecture of the unit’s (fig 3-4) input circuitry is based on a video table look-up ROM. The function
Parks, David R; Roederer, Mario; Moore, Wayne A
2006-06-01
In immunofluorescence measurements and most other flow cytometry applications, fluorescence signals of interest can range down to essentially zero. After fluorescence compensation, some cell populations will have low means and include events with negative data values. Logarithmic presentation has been very useful in providing informative displays of wide-ranging flow cytometry data, but it fails to adequately display cell populations with low means and high variances and, in particular, offers no way to include negative data values. This has led to a great deal of difficulty in interpreting and understanding flow cytometry data, has often resulted in incorrect delineation of cell populations, and has led many people to question the correctness of compensation computations that were, in fact, correct. We identified a set of criteria for creating data visualization methods that accommodate the scaling difficulties presented by flow cytometry data. On the basis of these, we developed a new data visualization method that provides important advantages over linear or logarithmic scaling for display of flow cytometry data, a scaling we refer to as "Logicle" scaling. Logicle functions represent a particular generalization of the hyperbolic sine function with one more adjustable parameter than linear or logarithmic functions. Finally, we developed methods for objectively and automatically selecting an appropriate value for this parameter. The Logicle display method provides more complete, appropriate, and readily interpretable representations of data that includes populations with low-to-zero means, including distributions resulting from fluorescence compensation procedures, than can be produced using either logarithmic or linear displays. The method includes a specific algorithm for evaluating actual data distributions and deriving parameters of the Logicle scaling function appropriate for optimal display of that data. It is critical to note that Logicle visualization does not change the data values or the descriptive statistics computed from them. Copyright 2006 International Society for Analytical Cytology.
Human Cells Display Reduced Apoptotic Function Relative to Chimpanzee Cells
McDonald, John F.
2012-01-01
Previously published gene expression analyses suggested that apoptotic function may be reduced in humans relative to chimpanzees and led to the hypothesis that this difference may contribute to the relatively larger size of the human brain and the increased propensity of humans to develop cancer. In this study, we sought to further test the hypothesis that humans maintain a reduced apoptotic function relative to chimpanzees by conducting a series of apoptotic function assays on human, chimpanzee and macaque primary fibroblastic cells. Human cells consistently displayed significantly reduced apoptotic function relative to the chimpanzee and macaque cells. These results are consistent with earlier findings indicating that apoptotic function is reduced in humans relative to chimpanzees. PMID:23029431
Advanced Transport Operating System (ATOPS) color displays software description: MicroVAX system
NASA Technical Reports Server (NTRS)
Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.
1992-01-01
This document describes the software created for the Display MicroVAX computer used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery of February 27, 1991, known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global references section includes subroutines, functions, and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight Cathode Ray Tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.
Research into display sharing techniques for distributed computing environments
NASA Technical Reports Server (NTRS)
Hugg, Steven B.; Fitzgerald, Paul F., Jr.; Rosson, Nina Y.; Johns, Stephen R.
1990-01-01
The X-based Display Sharing solution for distributed computing environments is described. The Display Sharing prototype includes the base functionality for telecast and display copy requirements. Since the prototype implementation is modular and the system design provided flexibility for the Mission Control Center Upgrade (MCCU) operational consideration, the prototype implementation can be the baseline for a production Display Sharing implementation. To facilitate the process the following discussions are presented: Theory of operation; System of architecture; Using the prototype; Software description; Research tools; Prototype evaluation; and Outstanding issues. The prototype is based on the concept of a dedicated central host performing the majority of the Display Sharing processing, allowing minimal impact on each individual workstation. Each workstation participating in Display Sharing hosts programs to facilitate the user's access to Display Sharing as host machine.
Does Mckuer's Law Hold for Heart Rate Control via Biofeedback Display?
NASA Technical Reports Server (NTRS)
Courter, B. J.; Jex, H. R.
1984-01-01
Some persons can control their pulse rate with the aid of a biofeedback display. If the biofeedback display is modified to show the error between a command pulse-rate and the measured rate, a compensatory (error correcting) heart rate tracking control loop can be created. The dynamic response characteristics of this control loop when subjected to step and quasi-random disturbances were measured. The control loop includes a beat-to-beat cardiotachmeter differenced with a forcing function from a quasi-random input generator; the resulting error pulse-rate is displayed as feedback. The subject acts to null the displayed pulse-rate error, thereby closing a compensatory control loop. McRuer's Law should hold for this case. A few subjects already skilled in voluntary pulse-rate control were tested for heart-rate control response. Control-law properties are derived, such as: crossover frequency, stability margins, and closed-loop bandwidth. These are evaluated for a range of forcing functions and for step as well as random disturbances.
Adaptation of Control Center Software to Commerical Real-Time Display Applications
NASA Technical Reports Server (NTRS)
Collier, Mark D.
1994-01-01
NASA-Marshall Space Flight Center (MSFC) is currently developing an enhanced Huntsville Operation Support Center (HOSC) system designed to support multiple spacecraft missions. The Enhanced HOSC is based upon a distributed computing architecture using graphic workstation hardware and industry standard software including POSIX, X Windows, Motif, TCP/IP, and ANSI C. Southwest Research Institute (SwRI) is currently developing a prototype of the Display Services application for this system. Display Services provides the capability to generate and operate real-time data-driven graphic displays. This prototype is a highly functional application designed to allow system end users to easily generate complex data-driven displays. The prototype is easy to use, flexible, highly functional, and portable. Although this prototype is being developed for NASA-MSFC, the general-purpose real-time display capability can be reused in similar mission and process control environments. This includes any environment depending heavily upon real-time data acquisition and display. Reuse of the prototype will be a straight-forward transition because the prototype is portable, is designed to add new display types easily, has a user interface which is separated from the application code, and is very independent of the specifics of NASA-MSFC's system. Reuse of this prototype in other environments is a excellent alternative to creation of a new custom application, or for environments with a large number of users, to purchasing a COTS package.
Antibody Fab display and selection through fusion to the pIX coat protein of filamentous phage.
Tornetta, Mark; Baker, Scott; Whitaker, Brian; Lu, Jin; Chen, Qiang; Pisors, Eileen; Shi, Lei; Luo, Jinquan; Sweet, Raymond; Tsui, Ping
2010-08-31
Fab antibody display on filamentous phage is widely applied to de novo antibody discovery and engineering. Here we describe a phagemid system for the efficient display and affinity selection of Fabs through linkage to the minor coat protein pIX. Display was successful by fusion of either Fd or Lc through a short linker to the amino terminus of pIX and co-expression of the counter Lc or Fd as a secreted, soluble fragment. Assembly of functional Fab was confirmed by demonstration of antigen-specific binding using antibodies of known specificity. Phage displaying a Fab specific for RSV-F protein with Fd linked to pIX showed efficient, antigen-specific enrichment when mixed with phage displaying a different specificity. The functionality of this system for antibody engineering was evaluated in an optimization study. A RSV-F protein specific antibody with an affinity of about 2nM was randomized at 4 positions in light chain CDR1. Three rounds of selection with decreasing antigen concentration yielded Fabs with an affinity improvement up to 70-fold and showed a general correlation between enrichment frequency and affinity. We conclude that the pIX coat protein complements other display systems in filamentous phage as an efficient vehicle for low copy display and selection of Fab proteins. 2010 Elsevier B.V. All rights reserved.
Wong, Chuan Loo; Yong, Chean Yeah; Muhamad, Azira; Syahir, Amir; Omar, Abdul Rahman; Sieo, Chin Chin; Tan, Wen Siang
2018-05-01
Foot-and-mouth disease (FMD) is a major threat to the livestock industry worldwide. Despite constant surveillance and effective vaccination, the perpetual mutations of the foot-and-mouth disease virus (FMDV) pose a huge challenge to FMD diagnosis. The immunodominant region of the FMDV VP1 protein (residues 131-170) displayed on phage T7 has been used to detect anti-FMDV in bovine sera. In the present study, the functional epitope was further delineated using amino acid sequence alignment, homology modelling and phage display. Two highly conserved regions (VP1 145-152 and VP1 159-170 ) were identified among different FMDV serotypes. The coding regions of these two epitopes were fused separately to the T7 genome and displayed on the phage particles. Interestingly, chimeric phage displaying the VP1 159-170 epitope demonstrated a higher antigenicity than that displaying the VP1 131-170 epitope. By contrast, phage T7 displaying the VP1 145-152 epitope did not react significantly with the anti-FMDV antibodies in vaccinated bovine sera. This study has successfully identified a smaller functional epitope, VP1 159-170 , located at the C-terminal end of the structural VP1 protein. The phage T7 displaying this shorter epitope is a promising diagnostic reagent to detect anti-FMDV antibodies in vaccinated animals.
Handa, T; Ishikawa, H; Shimizu, K; Kawamura, R; Nakayama, H; Sawada, K
2009-11-01
Virtual reality has recently been highlighted as a promising medium for visual presentation and entertainment. A novel apparatus for testing binocular visual function using a hemispherical visual display system, 'CyberDome', has been developed and tested. Subjects comprised 40 volunteers (mean age, 21.63 years) with corrected visual acuity of -0.08 (LogMAR) or better, and stereoacuity better than 100 s of arc on the Titmus stereo test. Subjects were able to experience visual perception like being surrounded by visual images, a feature of the 'CyberDome' hemispherical visual display system. Visual images to the right and left eyes were projected and superimposed on the dome screen, allowing test images to be seen independently by each eye using polarizing glasses. The hemispherical visual display was 1.4 m in diameter. Three test parameters were evaluated: simultaneous perception (subjective angle of strabismus), motor fusion amplitude (convergence and divergence), and stereopsis (binocular disparity at 1260, 840, and 420 s of arc). Testing was performed in volunteer subjects with normal binocular vision, and results were compared with those using a major amblyoscope. Subjective angle of strabismus and motor fusion amplitude showed a significant correlation between our test and the major amblyoscope. All subjects could perceive the stereoscopic target with a binocular disparity of 480 s of arc. Our novel apparatus using the CyberDome, a hemispherical visual display system, was able to quantitatively evaluate binocular function. This apparatus offers clinical promise in the evaluation of binocular function.
Kim, Hyun-Wook; Kim, Ji-Han; Yan, Feifei; Cheng, Heng-Wei; Brad Kim, Yuan H
2017-12-01
The present study aimed to evaluate the effects of heat stress and probiotic supplementation on protein functionality and oxidative stability of ground chicken leg during display storage. Two hundred and forty, 1-day-old male chicks (5 birds per pen) were subjected to four treatments in a 2 (thermoneutral condition at 21 °C and cyclic heat stress at 32-21-32 °C for 10 h day -1 ) × 2 (regular diet with 0 or 0.25 g kg -1 Bacillus subtilis) factorial design. Chickens were harvested at day 46, and pairs of whole legs were collected at 1 day postmortem. The chicken legs were deboned, ground, tray-packaged with oxygen-permeable film, and displayed for 3 days. Heat stress and probiotic supplementation had no impact on pH, water-holding capacity, color, protein functionality, lipid lipolysis and lipid/protein oxidation stability (P > 0.05). Display storage increased the pH and lipid oxidation of ground chicken legs (P < 0.05). In addition, protein oxidation occurred during display storage, as determined via an increased carbonyl group (P = 0.0109) and reduced thiol group (P < 0.0001). The results of the present study indicate that chronic heat stress and probiotic supplementation had no practical adverse impact on protein functionality and oxidative stability of ground chicken leg meat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, Caitlyn Christian
An evaporation barrier is required to enhance the lifetime of electrophoretic deposition (EPD) displays. As EPD functions on the basis of reversible deposition and resuspension of colloids suspended in a solvent, evaporation of the solvent ultimately leads to device failure. Incorporation of a thiol-polybutadiene elastomer into EPD displays enabled display lifetime surpassing six months in counting and catalyzed rigid display transition into a flexible package. Final flexible display transition to mass production compels an electronic-ink approach to encapsulate display suspension within an elastomer shell. Final thiol-polybutadiene photosensitive resin network microstructure was idealized to be dense, homogeneous, and expose an elasticmore » response to deformation. Research at hand details an approach to understanding microstructural change within display elastomers. Polybutadiene-based resin properties are modified via polymer chain structure, with and without added aromatic urethane methacrylate difunctionality, and in measuring network response to variation in thiol and initiator concentration. Dynamic mechanical analysis results signify that cross-linked segments within a difunctionalized polybutadiene network were on average eight times more elastically active than that of linked segments within a non-functionalized polybutadiene network. Difunctionalized polybutadiene samples also showed a 2.5 times greater maximum elastic modulus than non-functionalized samples. Hybrid polymer composed of both polybutadiene chains encompassed TE-2000 stiffness and B-1000 elasticity for use in encapsulating display suspension. Later experiments measured kinetic and rheological response due to alteration in dithiol cross-linker chain length via real time Fourier transform infrared spectroscopy and real-time dynamic rheology. Distinct differences were discovered between dithiol resin systems, as maximum thiol conversion achieved in short and long chain length dithiols was 86% and 11%, respectively. Oscillatory real-time rheological experiments confirmed a more uniform network to better dissipate applied shear in short chain length dithiol systems, as long chain length dithiols relayed a steep internal stress build-up due to less cross-links and chain entanglements. Thorough understanding of network formation aids the production of a stronger and impermeable elastomeric barrier for preservation of EPD displays.« less
Transgenic Analysis of the Role of FKBP12.6 in Cardiac Function and Intracellular Calcium Release
Liu, Ying; Chen, Hanying; Ji, Guangju; Li, Baiyan; Mohler, Peter J.; Zhu, Zhiming; Yong, Weidong; Chen, Zhuang; Xu, Xuehong
2011-01-01
Abstract FK506 binding protein12.6 (FKBP12.6) binds to the Ca2+ release channel ryanodine receptor (RyR2) in cardiomyocytes and stabilizes RyR2 to prevent premature sarcoplasmic reticulum Ca2+ release. Previously, two different mouse strains deficient in FKBP12.6 were reported to have different abnormal cardiac phenotypes. The first mutant strain displayed sex-dependent cardiac hypertrophy, while the second displayed exercise-induced cardiac arrhythmia and sudden death. In this study, we tested whether FKBP12.6-deficient mice that display hypertrophic hearts can develop exercise-induced cardiac sudden death and whether the hypertrophic heart is a direct consequence of abnormal calcium handling in mutant cardiomyocytes. Our data show that FKBP12.6-deficient mice with cardiac hypertrophy do not display exercise-induced arrhythmia and/or sudden cardiac death. To investigate the role of FKBP12.6 overexpression for cardiac function and cardiomyocyte calcium release, we generated a transgenic mouse line with cardiac specific overexpression of FKBP12.6 using α-myosin heavy chain (αMHC) promoter. MHC-FKBP12.6 mice displayed normal cardiac development and function. We demonstrated that MHC-FKBP12.6 mice are able to rescue abnormal cardiac hypertrophy and abnormal calcium release in FKBP12.6-deficient mice. PMID:22087651
Dynamic plasmonic colour display
NASA Astrophysics Data System (ADS)
Duan, Xiaoyang; Kamin, Simon; Liu, Na
2017-02-01
Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.
Dynamic plasmonic colour display.
Duan, Xiaoyang; Kamin, Simon; Liu, Na
2017-02-24
Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications.
Dynamic plasmonic colour display
Duan, Xiaoyang; Kamin, Simon; Liu, Na
2017-01-01
Plasmonic colour printing based on engineered metasurfaces has revolutionized colour display science due to its unprecedented subwavelength resolution and high-density optical data storage. However, advanced plasmonic displays with novel functionalities including dynamic multicolour printing, animations, and highly secure encryption have remained in their infancy. Here we demonstrate a dynamic plasmonic colour display technique that enables all the aforementioned functionalities using catalytic magnesium metasurfaces. Controlled hydrogenation and dehydrogenation of the constituent magnesium nanoparticles, which serve as dynamic pixels, allow for plasmonic colour printing, tuning, erasing and restoration of colour. Different dynamic pixels feature distinct colour transformation kinetics, enabling plasmonic animations. Through smart material processing, information encoded on selected pixels, which are indiscernible to both optical and scanning electron microscopies, can only be read out using hydrogen as a decoding key, suggesting a new generation of information encryption and anti-counterfeiting applications. PMID:28232722
NASA Technical Reports Server (NTRS)
Rorie, Conrad; Fern, Lisa; Pack, Jessica; Shively, Jay; Draper, Mark H.
2015-01-01
The pilot-in-the-loop Detect-and-Avoid (DAA) task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays.
Ochiai, Nobuhisa; Kondo, Hiroyuki
2017-01-01
The effects of color perception are utilized in visual displays for the purpose of safety in the workplace and in daily life. These effects, generally known as color functionality, are divided into four classifications: visibility, legibility, conspicuity and discriminability. This article focuses on the relationship between the color functionality of color schemes used in visual displays for occupational and environmental safety and color vision deficiency (particularly congenital red-green color deficiency), a critical issue in ophthalmology, and examines the effects of color functionality on the perception of the color red in individuals with protan defects. Due to abrupt system reforms, current Japanese clinical ophthalmology finds itself in a situation where it is insufficiently prepared to handle congenital red-green color deficiencies. Indeed, occupational problems caused by color vision deficiencies have been almost completely neglected, and are an occupational safety and health concern that will need to be solved in the future. This report will present the guidelines for the color vision testing established by the British Health and Safety Executive (HSE), a pioneering example of a model meant to solve these problems. Issues relating to the creation of guidelines adapted to Japanese clinical ophthalmology will also be examined, and we will discuss ways to utilize color functionality used in visual displays for occupational and environmental safety to help manage color vision deficiency.
1980-03-01
full-color terrain model designed to 6 ,. .. ., CINE MA ICiINE h MRO FILM To’ N U Ix v M C CTMIRROR MONITOR FRESNEL REAR- PROJECTION SCREEN Z...ments of NOE flight, recorded on videotape. One segment was filmed at the Hunter-Liggett, Calif., ntilitary reservation, and the other segment was... filmed near Fort Rucker, Ala. The tapes were viewed by each participant pilot on the 13-cm and the 26-cm CRT displays. They could attenuate the display
2011-01-01
Background Baculovirus, which has a width of 40 nm and a length of 250-300 nm, can display functional peptides, receptors and antigens on its surface by their fusion with a baculovirus envelop protein, GP64. In addition, some transmembrane proteins can be displayed without GP64 fusion, using the native transmembrane domains of the baculovirus. We used this functionality to display human prorenin receptor fused with GFPuv (GFPuv-hPRR) on the surface of silkworm Bombyx mori nucleopolyhedrovirus (BmNPV) and then tested whether these baculovirus particles could be used to detect protein-protein interactions. Results BmNPV displaying GFPuv-hPRR (BmNPV-GFPuv-hPRR) was purified from hemolymph by using Sephacryl S-1000 column chromatography in the presence of 0.01% Triton X-100. Its recovery was 86% and the final baculovirus particles number was 4.98 × 108 pfu. Based on the results of enzyme-linked immunosorbent assay (ELISA), 3.1% of the total proteins in BmNPV-GFPuv-hPRR were GFPuv-hPRR. This value was similar to that calculated from the result of western blot by a densitometry (2.7%). To determine whether BmNPV-GFPuv-hPRR particles were bound to human prorenin, ELISA results were compared with those from ELISAs using protease negative BmNPV displaying β1,3-N-acetylglucosaminyltransferase 2 fused with the gene encoding GFPuv (GGT2) (BmNPV-CP--GGT2) particles, which do not display hPRR on their surfaces. Conclusion The display of on the surface of the BmNPV particles will be useful for the detection of protein-protein interactions and the screening of inhibitors and drugs in their roles as nanobioparticles. PMID:21635720
Seo, Moon-Hyeong; Nim, Satra; Jeon, Jouhyun; Kim, Philip M
2017-01-01
Protein-protein interactions are essential to cellular functions and signaling pathways. We recently combined bioinformatics and custom oligonucleotide arrays to construct custom-made peptide-phage libraries for screening peptide-protein interactions, an approach we call proteomic peptide-phage display (ProP-PD). In this chapter, we describe protocols for phage display for the identification of natural peptide binders for a given protein. We finally describe deep sequencing for the analysis of the proteomic peptide-phage display.
Harnessing Novel Secreted Inhibitors of EGF Receptor Signaling for Breast Cancer Treatment
2007-04-01
the original proposal, we described approaches for displaying the basic Argos and Dkk scaffolds as pIII fusions on M13 phage , so that we could...deal of effort into displaying Argos and other relevant proteins as pIII fusions on M13 phage (Task 2a). This has been technically very challenging... display function Argos on the surface of phage M13 , requiring a change in experimental strategy • To replace the phage display , we have established
NASA Astrophysics Data System (ADS)
Morita, Yoshifumi; Hirose, Akinori; Uno, Takashi; Uchid, Masaki; Ukai, Hiroyuki; Matsui, Nobuyuki
2007-12-01
In this paper we propose a new rehabilitation training support system for upper limbs. The proposed system enables therapists to quantitatively evaluate the therapeutic effect of upper limb motor function during training, to easily change the load of resistance of training and to easily develop a new training program suitable for the subjects. For this purpose we develop control algorithms of training programs in the 3D force display robot. The 3D force display robot has parallel link mechanism with three motors. The control algorithm simulating sanding training is developed for the 3D force display robot. Moreover the teaching/training function algorithm is developed. It enables the therapists to easily make training trajectory suitable for subject's condition. The effectiveness of the developed control algorithms is verified by experiments.
A comparison of tracking with visual and kinesthetic-tactual displays
NASA Technical Reports Server (NTRS)
Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.
1981-01-01
Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under appropriate conditions it may be an effective means of providing visual workload relief. In order to better understand how KT tracking differs from visual tracking, both a critical tracking task and stationary single-axis tracking tasks were conducted with and without velocity quickening. On the critical tracking task, the visual displays were superior; however, the KT quickened display was approximately equal to the visual unquickened display. Mean squared error scores in the stationary tracking tasks for the visual and KT displays were approximately equal in the quickened conditions, and the describing functions were very similar. In the unquickened conditions, the visual display was superior. Subjects using the unquickened KT display exhibited a low frequency lead-lag that may be related to sensory adaptation.
Advanced electronic displays and their potential in future transport aircraft
NASA Technical Reports Server (NTRS)
Hatfield, J. J.
1981-01-01
It is pointed out that electronic displays represent one of the keys to continued integration and improvement of the effectiveness of avionic systems in future transport aircraft. An employment of modern electronic display media and generation has become vital in connection with the increases in modes and functions of modern aircraft. Requirements for electronic systems of future transports are examined, and a description is provided of the tools which are available for cockpit integration, taking into account trends in information processing and presentation, trends in integrated display devices, and trends concerning input/output devices. Developments related to display media, display generation, and I/O devices are considered, giving attention to a comparison of CRT and flat-panel display technology, advanced HUD technology and multifunction controls. Integrated display formats are discussed along with integrated systems and cockpit configurations.
Mobile display technologies: Past developments, present technologies, and future opportunities
NASA Astrophysics Data System (ADS)
Ohshima, Hiroyuki
2014-01-01
It has been thirty years since the first active matrix (AM) flat panel display (FPD) was industrialized for portable televisions (TVs) in 1984. The AM FPD has become a dominant electronic display technology widely used from mobile displays to large TVs. The development of AM FPDs for mobile displays has significantly changed our lives by enabling new applications, such as notebook personal computers (PCs), smartphones and tablet PCs. In the future, the role of mobile displays will become even more important, since mobile displays are the live interface for the world of mobile communications in the era of ubiquitous networks. Various developments are being conducted to improve visual performance, reduce power consumption and add new functionality. At the same time, innovative display concepts and novel manufacturing technologies are being investigated to create new values.
NASA Technical Reports Server (NTRS)
Mckee, James W.
1990-01-01
This volume (4 of 4) contains the description, structured flow charts, prints of the graphical displays, and source code to generate the displays for the AMPS graphical status system. The function of these displays is to present to the manager of the AMPS system a graphical status display with the hot boxes that allow the manager to get more detailed status on selected portions of the AMPS system. The development of the graphical displays is divided into two processes; the creation of the screen images and storage of them in files on the computer, and the running of the status program which uses the screen images.
Operator vision aids for space teleoperation assembly and servicing
NASA Technical Reports Server (NTRS)
Brooks, Thurston L.; Ince, Ilhan; Lee, Greg
1992-01-01
This paper investigates concepts for visual operator aids required for effective telerobotic control. Operator visual aids, as defined here, mean any operational enhancement that improves man-machine control through the visual system. These concepts were derived as part of a study of vision issues for space teleoperation. Extensive literature on teleoperation, robotics, and human factors was surveyed to definitively specify appropriate requirements. This paper presents these visual aids in three general categories of camera/lighting functions, display enhancements, and operator cues. In the area of camera/lighting functions concepts are discussed for: (1) automatic end effector or task tracking; (2) novel camera designs; (3) computer-generated virtual camera views; (4) computer assisted camera/lighting placement; and (5) voice control. In the technology area of display aids, concepts are presented for: (1) zone displays, such as imminent collision or indexing limits; (2) predictive displays for temporal and spatial location; (3) stimulus-response reconciliation displays; (4) graphical display of depth cues such as 2-D symbolic depth, virtual views, and perspective depth; and (5) view enhancements through image processing and symbolic representations. Finally, operator visual cues (e.g., targets) that help identify size, distance, shape, orientation and location are discussed.
"Head up and eyes out" advances in head mounted displays capabilities
NASA Astrophysics Data System (ADS)
Cameron, Alex
2013-06-01
There are a host of helmet and head mounted displays, flooding the market place with displays which provide what is essentially a mobile computer display. What sets aviators HMDs apart is that they provide the user with accurate conformal information embedded in the pilots real world view (see through display) where the information presented is intuitive and easy to use because it overlays the real world (mix of sensor imagery, symbolic information and synthetic imagery) and enables them to stay head up, eyes out, - improving their effectiveness, reducing workload and improving safety. Such systems are an enabling technology in the provision of enhanced Situation Awareness (SA) and reducing user workload in high intensity situations. Safety Is Key; so the addition of these HMD functions cannot detract from the aircrew protection functions of conventional aircrew helmets which also include life support and audio communications. These capabilities are finding much wider application in new types of compact man mounted audio/visual products enabled by the emergence of new families of micro displays, novel optical concepts and ultra-compact low power processing solutions. This papers attempts to capture the key drivers and needs for future head mounted systems for aviation applications.
Methods for Dichoptic Stimulus Presentation in Functional Magnetic Resonance Imaging - A Review
Choubey, Bhaskar; Jurcoane, Alina; Muckli, Lars; Sireteanu, Ruxandra
2009-01-01
Dichoptic stimuli (different stimuli displayed to each eye) are increasingly being used in functional brain imaging experiments using visual stimulation. These studies include investigation into binocular rivalry, interocular information transfer, three-dimensional depth perception as well as impairments of the visual system like amblyopia and stereodeficiency. In this paper, we review various approaches of displaying dichoptic stimulus used in functional magnetic resonance imaging experiments. These include traditional approaches of using filters (red-green, red-blue, polarizing) with optical assemblies as well as newer approaches of using bi-screen goggles. PMID:19526076
ERIC Educational Resources Information Center
Barbaro, Josephine; Dissanayake, Cheryl
2007-01-01
The use and understanding of self-presentational display rules (SPDRs) was investigated in 21 children with high-functioning autism (FHA), 18 children with Asperger's disorder (AspD) and 20 typically developing (TD) children (all male, aged 4- to 11-years, matched on mental age). Their behaviour was coded during a deception scenario to assess use…
Parent ratings of executive functioning in children with shunted hydrocephalus.
Lacy, Maureen; Baldassarre, Megan; Nader, Todd; Frim, David
2012-01-01
The present study examined the executive functioning of a group of children with a history of communicating hydrocephalus and how their level of functioning was correlated with parent ratings of executive functioning. The study examined the executive functioning of 39 shunted children with a history of hydrocephalus and 20 healthy peers. Additionally, parents of both groups of children completed the Behavior Rating Inventory of Executive Function (BRIEF) to assess the parents' perceptions of their children's executive functioning. Finally, the study investigated the relationship between the shunted hydrocephalus children's executive functioning and the parent ratings of their executive functioning. Overall, the children with a history of shunted hydrocephalus displayed more executive dysfunction than their healthy peers. These children were rated by their parents as having more executive dysfunction than their healthy peers and displaying working memory, initiation, mental flexibility and self-monitoring difficulties, which appear to increase with age among the shunted hydrocephalus group. While parent ratings as measured by the BRIEF indices did not correlate with all executive tasks within the shunted hydrocephalus group, the cognitive tests assessing mental flexibility may be sensitive to the problems noted by parents at home. The children with a history of shunted hydrocephalus displayed executive functioning deficits on formal examination. The parents of children with a history of shunted hydrocephalus report ongoing executive difficulties which may increase with age. Copyright © 2012 S. Karger AG, Basel.
Wang, Zhiyuan; Lleras, Alejandro; Buetti, Simona
2018-04-17
Our lab recently found evidence that efficient visual search (with a fixed target) is characterized by logarithmic Reaction Time (RT) × Set Size functions whose steepness is modulated by the similarity between target and distractors. To determine whether this pattern of results was based on low-level visual factors uncontrolled by previous experiments, we minimized the possibility of crowding effects in the display, compensated for the cortical magnification factor by magnifying search items based on their eccentricity, and compared search performance on such displays to performance on displays without magnification compensation. In both cases, the RT × Set Size functions were found to be logarithmic, and the modulation of the log slopes by target-distractor similarity was replicated. Consistent with previous results in the literature, cortical magnification compensation eliminated most target eccentricity effects. We conclude that the log functions and their modulation by target-distractor similarity relations reflect a parallel exhaustive processing architecture for early vision.
Innovative railroad information displays for dispatch and train engineer functions
DOT National Transportation Integrated Search
1996-02-29
A useful information display system must be able to maintain the users sense of : context by keeping the important information clearly viewable and conserving : important relationships, while subduing information not currently relevant. : The Visible...
Human factors of intelligent computer aided display design
NASA Technical Reports Server (NTRS)
Hunt, R. M.
1985-01-01
Design concepts for a decision support system being studied at NASA Langley as an aid to visual display unit (VDU) designers are described. Ideally, human factors should be taken into account by VDU designers. In reality, although the human factors database on VDUs is small, such systems must be constantly developed. Human factors are therefore a secondary consideration. An expert system will thus serve mainly in an advisory capacity. Functions can include facilitating the design process by shortening the time to generate and alter drawings, enhancing the capability of breaking design requirements down into simpler functions, and providing visual displays equivalent to the final product. The VDU system could also discriminate, and display the difference, between designer decisions and machine inferences. The system could also aid in analyzing the effects of designer choices on future options and in ennunciating when there are data available on a design selections.
Method and apparatus for non-invasive evaluation of diaphragmatic function
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Wait, Juliette L. (Inventor); Nahormek, Patricia A. (Inventor); Cantrell, John H. (Inventor); Hanna-Hawver, Pamela D. (Inventor)
1995-01-01
A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.
Method and apparatus for non-invasive evaluation of diaphragmatic function
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Wait, Juliette L. (Inventor); Nahormek, Patricia A. (Inventor); Cantrell, John H. (Inventor); Hanna-Hawver, Pamela D. (Inventor)
1994-01-01
A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.
Fourier holographic display for augmented reality using holographic optical element
NASA Astrophysics Data System (ADS)
Li, Gang; Lee, Dukho; Jeong, Youngmo; Lee, Byoungho
2016-03-01
A method for realizing a three-dimensional see-through augmented reality in Fourier holographic display is proposed. A holographic optical element (HOE) with the function of Fourier lens is adopted in the system. The Fourier hologram configuration causes the real scene located behind the lens to be distorted. In the proposed method, since the HOE is transparent and it functions as the lens just for Bragg matched condition, there is not any distortion when people observe the real scene through the lens HOE (LHOE). Furthermore, two optical characteristics of the recording material are measured for confirming the feasibility of using LHOE in the proposed see-through augmented reality holographic display. The results are verified experimentally.
Display characterization by eye: contrast ratio and discrimination throughout the grayscale
NASA Astrophysics Data System (ADS)
Gille, Jennifer; Arend, Larry; Larimer, James O.
2004-06-01
We have measured the ability of observers to estimate the contrast ratio (maximum white luminance / minimum black or gray) of various displays and to assess luminous discrimination over the tonescale of the display. This was done using only the computer itself and easily-distributed devices such as neutral density filters. The ultimate goal of this work is to see how much of the characterization of a display can be performed by the ordinary user in situ, in a manner that takes advantage of the unique abilities of the human visual system and measures visually important aspects of the display. We discuss the relationship among contrast ratio, tone scale, display transfer function and room lighting. These results may contribute to the development of applications that allow optimization of displays for the situated viewer / display system without instrumentation and without indirect inferences from laboratory to workplace.
Network Control Center User Planning System (NCC UPS)
NASA Astrophysics Data System (ADS)
Dealy, Brian
1991-09-01
NCC UPS is presented in the form of the viewgraphs. The following subject areas are covered: UPS overview; NCC UPS role; major NCC UPS functional requirements; interactive user access levels; UPS interfaces; interactive user subsystem; interface navigation; scheduling screen hierarchy; interactive scheduling input panels; autogenerated schedule request panel; schedule data tabular display panel; schedule data graphic display panel; graphic scheduling aid design; and schedule data graphic display.
Network Control Center User Planning System (NCC UPS)
NASA Technical Reports Server (NTRS)
Dealy, Brian
1991-01-01
NCC UPS is presented in the form of the viewgraphs. The following subject areas are covered: UPS overview; NCC UPS role; major NCC UPS functional requirements; interactive user access levels; UPS interfaces; interactive user subsystem; interface navigation; scheduling screen hierarchy; interactive scheduling input panels; autogenerated schedule request panel; schedule data tabular display panel; schedule data graphic display panel; graphic scheduling aid design; and schedule data graphic display.
Chen, Minyong; Samuelson, James C
2016-06-14
The requirements for target protein folding in M13 phage display are largely underappreciated. Here we chose Fbs1, a carbohydrate binding protein, as a model to address this issue. Importantly, folding of Fbs1 is impaired in an oxidative environment. Fbs1 can be displayed on M13 phage using the SRP or Sec pathway. However, the displayed Fbs1 protein is properly folded only when Fbs1 is translocated via the SRP pathway and displayed using Escherichia coli cells with a DsbA-negative periplasm. This study indicates M13 phage display may be improved using a system specifically designed according to the folding requirements of each target protein.
The effects of control-display gain on performance of race car drivers in an isometric braking task.
de Winter, J C F; de Groot, S
2012-12-01
To minimise lap times during car racing, it is important to build up brake forces rapidly and maintain precise control. We examined the effect of the amplification factor (gain) between brake pedal force and a visually represented output value on a driver's ability to track a target value. The test setup was a formula racing car cockpit fitted with an isometric brake pedal. Thirteen racing drivers performed tracking tasks with four control-display gains and two target functions: a step function (35 trials per gain) and a multisine function (15 trials per gain). The control-display gain had only minor effects on root mean-squared error between output value and target value, but it had large effects on build-up speed, overshoot, within-participants variability, and self-reported physical load. The results confirm the hypothesis that choosing an optimum gain involves balancing stability against physical effort.
Cancel, Jesse D; Larsen, Paul B
2002-08-01
Ethylene signaling in Arabidopsis begins at a family of five ethylene receptors that regulate activity of a downstream mitogen-activated protein kinase kinase kinase, CTR1. Triple and quadruple loss-of-function ethylene receptor mutants display a constitutive ethylene response phenotype, indicating they function as negative regulators in this pathway. No ethylene-related phenotype has been described for single loss-of-function receptor mutants, although it was reported that etr1 loss-of-function mutants display a growth defect limiting plant size. In actuality, this apparent growth defect results from enhanced responsiveness to ethylene; a phenotype manifested in all tissues tested. The phenotype displayed by etr1 loss-of-function mutants was rescued by treatment with an inhibitor of ethylene perception, indicating that it is ethylene dependent. Identification of an ethylene-dependent phenotype for a loss-of-function receptor mutant gave a unique opportunity for genetic and biochemical analysis of upstream events in ethylene signaling, including demonstration that the dominant ethylene-insensitive phenotype of etr2-1 is partially dependent on ETR1. This work demonstrates that mutational loss of the ethylene receptor ETR1 alters responsiveness to ethylene in Arabidopsis and that enhanced ethylene response in Arabidopsis not only results in increased sensitivity but exaggeration of response.
Cancel, Jesse D.; Larsen, Paul B.
2002-01-01
Ethylene signaling in Arabidopsis begins at a family of five ethylene receptors that regulate activity of a downstream mitogen-activated protein kinase kinase kinase, CTR1. Triple and quadruple loss-of-function ethylene receptor mutants display a constitutive ethylene response phenotype, indicating they function as negative regulators in this pathway. No ethylene-related phenotype has been described for single loss-of-function receptor mutants, although it was reported that etr1 loss-of-function mutants display a growth defect limiting plant size. In actuality, this apparent growth defect results from enhanced responsiveness to ethylene; a phenotype manifested in all tissues tested. The phenotype displayed by etr1 loss-of-function mutants was rescued by treatment with an inhibitor of ethylene perception, indicating that it is ethylene dependent. Identification of an ethylene-dependent phenotype for a loss-of-function receptor mutant gave a unique opportunity for genetic and biochemical analysis of upstream events in ethylene signaling, including demonstration that the dominant ethylene-insensitive phenotype of etr2-1 is partially dependent on ETR1. This work demonstrates that mutational loss of the ethylene receptor ETR1 alters responsiveness to ethylene in Arabidopsis and that enhanced ethylene response in Arabidopsis not only results in increased sensitivity but exaggeration of response. PMID:12177468
Assessment of Innovative Emergency Department Information Displays in a Clinical Simulation Center
McGeorge, Nicolette; Hegde, Sudeep; Berg, Rebecca L.; Guarrera-Schick, Theresa K.; LaVergne, David T.; Casucci, Sabrina N.; Hettinger, A. Zachary; Clark, Lindsey N.; Lin, Li; Fairbanks, Rollin J.; Benda, Natalie C.; Sun, Longsheng; Wears, Robert L.; Perry, Shawna; Bisantz, Ann
2016-01-01
The objective of this work was to assess the functional utility of new display concepts for an emergency department information system created using cognitive systems engineering methods, by comparing them to similar displays currently in use. The display concepts were compared to standard displays in a clinical simulation study during which nurse-physician teams performed simulated emergency department tasks. Questionnaires were used to assess the cognitive support provided by the displays, participants’ level of situation awareness, and participants’ workload during the simulated tasks. Participants rated the new displays significantly higher than the control displays in terms of cognitive support. There was no significant difference in workload scores between the display conditions. There was no main effect of display type on situation awareness, but there was a significant interaction; participants using the new displays showed improved situation awareness from the middle to the end of the session. This study demonstrates that cognitive systems engineering methods can be used to create innovative displays that better support emergency medicine tasks, without increasing workload, compared to more standard displays. These methods provide a means to develop emergency department information systems—and more broadly, health information technology—that better support the cognitive needs of healthcare providers. PMID:27974881
User's manual for flight Simulator Display System (FSDS)
NASA Technical Reports Server (NTRS)
Egerdahl, C. C.
1979-01-01
The capabilities of the flight simulator display system (FSDS) are described. FSDS is a color raster scan display generator designed to meet the special needs of Flight Simulation Laboratories. The FSDS can update (revise) the images it generates every 16.6 mS, with limited support from a host processor. This corresponds to the standard TV vertical rate of 60 Hertz, and allows the system to carry out display functions in a time critical environment. Rotation of a complex image in the television raster with minimal hardware is possible with the system.
Humanization of work circumstances in dialog communication using data display devices, volume 1
NASA Astrophysics Data System (ADS)
Graunke, H.; Julich, H.; Petersen, H. C.; Schaefer, H.; Strupp, K.
1982-11-01
The effects of data display on working places was investigated. Data processing by data display devices is not considered. Important criteria for job contentment is the integration into complex job structures. Corresponding to this principle of organization is team work with a flexible way of labor division which provides the chance and the motivation for a cooperative self controlled working process which give strain caused by data display devices. It is found that in public administration a team with an institutional leadership with primarily social integrative functions is appreciated most.
Display of adenoregulin with a novel Pichia pastoris cell surface display system.
Ren, Ren; Jiang, Zhengbing; Liu, Meiyun; Tao, Xinyi; Ma, Yushu; Wei, Dongzhi
2007-02-01
Two Pichia pastoris cell surface display vectors were constructed. The vectors consisted of the flocculation functional domain of Flo1p with its own secretion signal sequence or the alpha-factor secretion signal sequence, a polyhistidine (6xHis) tag for detection, an enterokinase recognition site, and the insertion sites for target proteins. Adenoregulin (ADR) is a 33-amino-acid antimicrobial peptide isolated from Phyllomedusa bicolor skin. The ADR was expressed and displayed on the Pichia pastoris KM71 cell surface with the system reported. The displayed recombinant ADR fusion protein was detected by fluorescence microscopy and confocal laser scanning microscopy (CLSM). The antimicrobial activity of the recombinant adenoregulin was detected after proteolytic cleavage of the fusion protein on cell surface. The validity of the Pichia pastoris cell surface display vectors was proved by the displayed ADR.
NASA Astrophysics Data System (ADS)
Veligdan, James T.; Beiser, Leo; Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard
1997-07-01
The polyplanar optical display (POD) is a unique display screen which can be use with any projection source. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a 100 milliwatt green solid state laser as its optical source. In order to produce real- time video, the laser light is being modulated by a digital light processing (DLP) chip manufactured by Texas Instruments, Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design, we discuss the electronic interfacing to the DLP chip, the opto-mechanical design and viewing angle characteristics.
Laser-driven polyplanar optic display
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veligdan, J.T.; Biscardi, C.; Brewster, C.
1998-01-01
The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. This display screen is 2 inches thick and has a matte-black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a 200 milliwatt green solid-state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLP) chip manufactured by Texas Instruments, Inc. A variablemore » astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design, the authors discuss the DLP chip, the optomechanical design and viewing angle characteristics.« less
Laser-driven polyplanar optic display
NASA Astrophysics Data System (ADS)
Veligdan, James T.; Beiser, Leo; Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard
1998-05-01
The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. This display screen is 2 inches thick and has a matte-black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a 200 milliwatt green solid- state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLPTM) chip manufactured by Texas Instruments, Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design, we discuss the DLPTM chip, the opto-mechanical design and viewing angle characteristics.
NASA Astrophysics Data System (ADS)
Doyon-Poulin, Philippe
Flight deck of 21st century commercial aircrafts does not look like the one the Wright brothers used for their first flight. The rapid growth of civilian aviation resulted in an increase in the number of flight deck instruments and of their complexity, in order to complete a safe and ontime flight. However, presenting an abundance of visual information using visually cluttered flight instruments might reduce the pilot's flight performance. Visual clutter has received an increased interest by the aerospace community to understand the effects of visual density and information overload on pilots' performance. Aerospace regulations demand to minimize visual clutter of flight deck displays. Past studies found a mixed effect of visual clutter of the primary flight display on pilots' technical flight performance. More research is needed to better understand this subject. In this thesis, we did an experimental study in a flight simulator to test the effects of visual clutter of the primary flight display on the pilot's technical flight performance, mental workload and gaze pattern. First, we identified a gap in existing definitions of visual clutter and we proposed a new definition relevant to the aerospace community that takes into account the context of use of the display. Then, we showed that past research on the effects of visual clutter of the primary flight display on pilots' performance did not manipulate the variable of visual clutter in a similar manner. Past research changed visual clutter at the same time than the flight guidance function. Using a different flight guidance function between displays might have masked the effect of visual clutter on pilots' performance. To solve this issue, we proposed three requirements that all tested displays must satisfy to assure that only the variable of visual clutter is changed during study while leaving other variables unaffected. Then, we designed three primary flight displays with a different visual clutter level (low, medium, high) but with the same flight guidance function, by respecting the previous requirements. Twelve pilots, with a mean experience of over 4000 total flight hours, completed an instrument landing in a flight simulator using all three displays for a total of nine repetitions. Our results showed that pilots reported lower workload level and had better lateral precision during the approach using the medium-clutter display compared to the low- and high-clutter displays. Also, pilots reported that the medium-clutter display was the most useful for the flight task compared to the two other displays. Eye tracker results showed that pilots' gaze pattern was less efficient for the high-clutter display compared to the low- and medium-clutter displays. Overall, these new experimental results emphasize the importance of optimizing visual clutter of flight displays as it affects both objective and subjective performance of experienced pilots in their flying task. This thesis ends with practical recommendations to help designers optimize visual clutter of displays used for man-machine interface.
CLIPS interface development tools and their application
NASA Technical Reports Server (NTRS)
Engel, Bernard A.; Rewerts, Chris C.; Srinivasan, Raghavan; Rogers, Joseph B.; Jones, Don D.
1990-01-01
A package of C-based PC user interface development functions has been developed and integrated into CLIPS. The primary function is ASK which provides a means to ask the user questions via multiple choice menus or the keyboard and then returns the user response to CLIPS. A parameter-like structure supplies information for the interface. Another function, SHOW, provides a means to paginate and display text. A third function, TITLE, formats and displays title screens. A similar set of C-based functions that are more general and thus will run on UNIX and machines have also been developed. Seven expert system applications were transformed from commercial development environments into CLIPS and utilize ASK, SHOW, and TITLE. Development of numerous new expert system applications using CLIPS and these interface functions has started. These functions greatly reduce the time required to build interfaces for CLIPS applications.
NASA Technical Reports Server (NTRS)
Syroid, Noah (Inventor); Westinskow, Dwayne (Inventor); Agutter, James (Inventor); Albert, Robert (Inventor); Strayer, David (Inventor); Wachter, S. Blake (Inventor); Drews, Frank (Inventor)
2010-01-01
A method, system, apparatus and device for the monitoring, diagnosis and evaluation of the state of a dynamic pulmonary system is disclosed. This method and system provides the processing means for receiving sensed and/or simulated data, converting such data into a displayable object format and displaying such objects in a manner such that the interrelationships between the respective variables can be correlated and identified by a user. This invention provides for the rapid cognitive grasp of the overall state of a pulmonary critical function with respect to a dynamic system.
Cockpit display of traffic information (CDTI) and airport moving map industry survey
DOT National Transportation Integrated Search
2016-08-01
This document provides an overview of Cockpit Display of Traffic Information (CDTI) products as of May 2016, including those with airport moving map functionality, and airport moving map applications without traffic depiction. This document updates a...
Geyer, Thomas; Baumgartner, Florian; Müller, Hermann J.; Pollmann, Stefan
2012-01-01
Using visual search, functional magnetic resonance imaging (fMRI) and patient studies have demonstrated that medial temporal lobe (MTL) structures differentiate repeated from novel displays—even when observers are unaware of display repetitions. This suggests a role for MTL in both explicit and, importantly, implicit learning of repeated sensory information (Greene et al., 2007). However, recent behavioral studies suggest, by examining visual search and recognition performance concurrently, that observers have explicit knowledge of at least some of the repeated displays (Geyer et al., 2010). The aim of the present fMRI study was thus to contribute new evidence regarding the contribution of MTL structures to explicit vs. implicit learning in visual search. It was found that MTL activation was increased for explicit and, respectively, decreased for implicit relative to baseline displays. These activation differences were most pronounced in left anterior parahippocampal cortex (aPHC), especially when observers were highly trained on the repeated displays. The data are taken to suggest that explicit and implicit memory processes are linked within MTL structures, but expressed via functionally separable mechanisms (repetition-enhancement vs. -suppression). They further show that repetition effects in visual search would have to be investigated at the display level. PMID:23060776
NASA Astrophysics Data System (ADS)
Li, Zhenwei; Sun, Jianyong; Zhang, Jianguo
2012-02-01
As more and more CT/MR studies are scanning with larger volume of data sets, more and more radiologists and clinician would like using PACS WS to display and manipulate these larger data sets of images with 3D rendering features. In this paper, we proposed a design method and implantation strategy to develop 3D image display component not only with normal 3D display functions but also with multi-modal medical image fusion as well as compute-assisted diagnosis of coronary heart diseases. The 3D component has been integrated into the PACS display workstation of Shanghai Huadong Hospital, and the clinical practice showed that it is easy for radiologists and physicians to use these 3D functions such as multi-modalities' (e.g. CT, MRI, PET, SPECT) visualization, registration and fusion, and the lesion quantitative measurements. The users were satisfying with the rendering speeds and quality of 3D reconstruction. The advantages of the component include low requirements for computer hardware, easy integration, reliable performance and comfortable application experience. With this system, the radiologists and the clinicians can manipulate with 3D images easily, and use the advanced visualization tools to facilitate their work with a PACS display workstation at any time.
Sex-related differences in amygdala functional connectivity during resting conditions.
Kilpatrick, L A; Zald, D H; Pardo, J V; Cahill, L F
2006-04-01
Recent neuroimaging studies have established a sex-related hemispheric lateralization of amygdala involvement in memory for emotionally arousing material. Here, we examine the possibility that sex-related differences in amygdala involvement in memory for emotional material develop from differential patterns of amygdala functional connectivity evident in the resting brain. Seed voxel partial least square analyses of regional cerebral blood flow data revealed significant sex-related differences in amygdala functional connectivity during resting conditions. The right amygdala was associated with greater functional connectivity in men than in women. In contrast, the left amygdala was associated with greater functional connectivity in women than in men. Furthermore, the regions displaying stronger functional connectivity with the right amygdala in males (sensorimotor cortex, striatum, pulvinar) differed from those displaying stronger functional connectivity with the left amygdala in females (subgenual cortex, hypothalamus). These differences in functional connectivity at rest may link to sex-related differences in medical and psychiatric disorders.
Velappan, Nileena; Fisher, Hugh E; Pesavento, Emanuele; Chasteen, Leslie; D'Angelo, Sara; Kiss, Csaba; Longmire, Michelle; Pavlik, Peter; Bradbury, Andrew R M
2010-03-01
Filamentous phage display has been extensively used to select proteins with binding properties of specific interest. Although many different display platforms using filamentous phage have been described, no comprehensive comparison of their abilities to display similar proteins has been conducted. This is particularly important for the display of cytoplasmic proteins, which are often poorly displayed with standard filamentous phage vectors. In this article, we have analyzed the ability of filamentous phage to display a stable form of green fluorescent protein and modified variants in nine different display vectors, a number of which have been previously proposed as being suitable for cytoplasmic protein display. Correct folding and display were assessed by phagemid particle fluorescence, and with anti-GFP antibodies. The poor correlation between phagemid particle fluorescence and recognition of GFP by antibodies, indicates that proteins may fold correctly without being accessible for display. The best vector used a twin arginine transporter leader to transport the displayed protein to the periplasm, and a coil-coil arrangement to link the displayed protein to g3p. This vector was able to display less robust forms of GFP, including ones with inserted epitopes, as well as fluorescent proteins of the Azami green series. It was also functional in mock selection experiments.
Geographic Data Display Implementation
1977-06-01
display to be either multiplied or divided by the magnification factor (normally 1.5). The result is a change of extent around the cursor as seen in... Products printer and a 200-card- per-minute card reader with the Interdata 4 (1-4). The 1-4 with its 64K of core is the applications machine connected...storing these values in the CURSTA array. 57 ZOOM IN FUNCTION KEY ZOOM OUT FUNCTION KEY ZMINTP ZMOUTP SET ZOOM OUT MAG FACTOR ZOMTOP SET
Effect of stationary objects on illusory forward self-motion induced by a looming display.
Ohmi, M; Howard, I P
1988-01-01
It has previously been shown that when a moving and a stationary display are superimposed, illusory self-rotation (circular vection) is induced only when the moving display appears as the background. Three experiments are reported on the extent to which illusory forward self-motion (forward vection) induced by a looming display is inhibited by a superimposed stationary display as a function of the size and location of the stationary display and of the depth between the stationary and looming displays. Results showed that forward vection was controlled by the display that was perceived as the background, and background stationary displays suppressed forward vection by about the same amount whatever their size and eccentricity. Also, the perception of foreground-background properties of competing displays determined which controlled forward vection, and this control was not tied to specific depth cues. The inhibitory effect of a stationary background on forward vection was, however, weaker than that found with circular vection. This difference makes sense because, for forward body motion, the image of a distant scene is virtually stationary whereas, when the body rotates, it is not.
NASA Astrophysics Data System (ADS)
Horii, Steven C.; Kundel, Harold L.; Shile, Peter E.; Carey, Bruce; Seshadri, Sridhar B.; Feingold, Eric R.
1994-05-01
As part of a study of the use of a PACS workstation compared to film in a Medical Intensive Care Unit, logs of workstation activity were maintained. The software for the workstation kept track of the type of user (i.e., intern, resident, fellow, or attending physician) and also of the workstation image manipulation functions used. The functions logged were: no operation, brightness/contrast adjustment, invert video, zoom, and high resolution display (this last function resulted in the display of the full 2 K X 2 K image rather than the usual subsampled 1 K X 1 K image. Associated data collection allows us to obtain the diagnostic category of the examination being viewed (e.g., location of tubes and lines, rule out: pneumonia, congestive heart failure, pneumothorax, and pleural effusion). The diagnostic categories and user type were then correlated with the use of workstation functions during viewing of images. In general, there was an inverse relationship between the level of training and the number of workstation uses. About two-thirds of the time, there was no image manipulation operation performed. Adjustment of brightness/contrast had the highest percentage of use overall, followed by zoom, video invert, and high resolution display.
Precise documentation of well-structured programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parnas, D.L.; Madey, J.; Iglewski, M.
1997-11-01
This paper describes a new form of program documentation that is precise, systematic and readable. This documentation comprises a set of displays supplemented by a lexicon and an index. Each display presents a program fragment in such a way that its correctness can be examined without looking at any other display. Each display has three parts: (1) the specification of the program presented in the display, (2) the program itself, and (3) the specifications of programs invoked by this program. The displays are intended to be used by Software Engineers as a reference document during inspection and maintenance. This papermore » also introduces a specification technique that is a refinement of Mills functional approach to program documentation and verification; programs are specified and described in tabular form.« less
Accommodation measurements of horizontally scanning holographic display.
Takaki, Yasuhiro; Yokouchi, Masahito
2012-02-13
Eye accommodation is considered to function properly for three-dimensional (3D) images generated by holography. We developed a horizontally scanning holographic display technique that enlarges both the screen size and viewing zone angle. A 3D image generated by this technique can be easily seen by both eyes. In this study, we measured the accommodation responses to a 3D image generated by the horizontally scanning holographic display technique that has a horizontal viewing zone angle of 14.6° and screen size of 4.3 in. We found that the accommodation responses to a 3D image displayed within 400 mm from the display screen were similar to those of a real object.
Redesigning of Microbial Cell Surface and Its Application to Whole-Cell Biocatalysis and Biosensors.
Han, Lei; Zhao, Yukun; Cui, Shan; Liang, Bo
2018-06-01
Microbial cell surface display technology can redesign cell surfaces with functional proteins and peptides to endow cells some unique features. Foreign peptides or proteins are transported out of cells and immobilized on cell surface by fusing with anchoring proteins, which is an effective solution to avoid substance transfer limitation, enzyme purification, and enzyme instability. As the most frequently used prokaryotic and eukaryotic protein surface display system, bacterial and yeast surface display systems have been widely applied in vaccine, biocatalysis, biosensor, bioadsorption, and polypeptide library screening. In this review of bacterial and yeast surface display systems, different cell surface display mechanisms and their applications in biocatalysis as well as biosensors are described with their strengths and shortcomings. In addition to single enzyme display systems, multi-enzyme co-display systems are presented here. Finally, future developments based on our and other previous reports are discussed.
Polyplanar optic display for cockpit application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veligdan, J.; Biscardi, C.; Brewster, C.
1998-04-01
The Polyplanar Optical Display (POD) is a high contrast display screen being developed for cockpit applications. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a long lifetime, (10,000 hour), 200 mW green solid-state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments,more » Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design and speckle reduction, the authors discuss the electronic interfacing to the DLP{trademark} chip, the opto-mechanical design and viewing angle characteristics.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veligdan, J.; Biscardi, C.; Brewster, C.
1997-07-01
The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a 100 milliwatt green solid state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments, Inc.more » A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design, the authors discuss the electronic interfacing to the DLP{trademark} chip, the opto-mechanical design and viewing angle characteristics.« less
Polyplanar optic display for cockpit application
NASA Astrophysics Data System (ADS)
Veligdan, James T.; Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Freibott, William C.
1998-09-01
The Polyplanar Optical Display (POD) is a high contrast display screen being developed for cockpit applications. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a long lifetime, (10,000 hour), 200 mW green solid-state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLPTM) chip manufactured by Texas Instruments, Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design and speckle reduction, we discuss the electronic interfacing to the DLPTM chip, the opto-mechanical design and viewing angle characteristics.
Zantow, Jonas; Moreira, Gustavo Marçal Schmidt Garcia; Dübel, Stefan; Hust, Michael
2018-01-01
ORFeome phage display allows the efficient functional screening of entire proteomes or even metaproteomes to identify immunogenic proteins. For this purpose, randomly fragmented, whole genomes or metagenomes are cloned into a phage-display vector allowing positive selection for open reading frames (ORF) to improve the library quality. These libraries display all possible proteins encoded by a pathogen or a microbiome on the phage surface. Consequently, immunogenic proteins can be selected from these libraries using disease-related immunoglobulins from patient serum. ORFeome phage display in particular allows the identification of immunogenic proteins that are only expressed in the host-pathogen interaction but not in cultivation, as well as the detection of very low expressed and very small immunogens and immunogenic proteins of non-cultivable organisms. The identified immunogenic proteins are potential biomarkers for the development of diagnostic assays or vaccines. These articles will give an introduction to ORFeome phage-display technology and give detailed protocols to identify immunogenic proteins by phage display.
Advancement and applications of peptide phage display technology in biomedical science.
Wu, Chien-Hsun; Liu, I-Ju; Lu, Ruei-Min; Wu, Han-Chung
2016-01-19
Combinatorial phage library is a powerful research tool for high-throughput screening of protein interactions. Of all available molecular display techniques, phage display has proven to be the most popular approach. Screening phage-displayed random peptide libraries is an effective means of identifying peptides that can bind target molecules and regulate their function. Phage-displayed peptide libraries can be used for (i) B-cell and T-cell epitope mapping, (ii) selection of bioactive peptides bound to receptors or proteins, disease-specific antigen mimics, peptides bound to non-protein targets, cell-specific peptides, or organ-specific peptides, and (iii) development of peptide-mediated drug delivery systems and other applications. Targeting peptides identified using phage display technology may be useful for basic research and translational medicine. In this review article, we summarize the latest technological advancements in the application of phage-displayed peptide libraries to applied biomedical sciences.
McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan
2016-01-01
Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.
McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan
2016-01-01
Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the “wild”. We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain’s Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design. PMID:27242480
A new display stream compression standard under development in VESA
NASA Astrophysics Data System (ADS)
Jacobson, Natan; Thirumalai, Vijayaraghavan; Joshi, Rajan; Goel, James
2017-09-01
The Advanced Display Stream Compression (ADSC) codec project is in development in response to a call for technologies from the Video Electronics Standards Association (VESA). This codec targets visually lossless compression of display streams at a high compression rate (typically 6 bits/pixel) for mobile/VR/HDR applications. Functionality of the ADSC codec is described in this paper, and subjective trials results are provided using the ISO 29170-2 testing protocol.
Display management subsystem, version 1: A user's eye view
NASA Technical Reports Server (NTRS)
Parker, Dolores
1986-01-01
The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.
Miniaturized LEDs for flat-panel displays
NASA Astrophysics Data System (ADS)
Radauscher, Erich J.; Meitl, Matthew; Prevatte, Carl; Bonafede, Salvatore; Rotzoll, Robert; Gomez, David; Moore, Tanya; Raymond, Brook; Cok, Ronald; Fecioru, Alin; Trindade, António Jose; Fisher, Brent; Goodwin, Scott; Hines, Paul; Melnik, George; Barnhill, Sam; Bower, Christopher A.
2017-02-01
Inorganic light emitting diodes (LEDs) serve as bright pixel-level emitters in displays, from indoor/outdoor video walls with pixel sizes ranging from one to thirty millimeters to micro displays with more than one thousand pixels per inch. Pixel sizes that fall between those ranges, roughly 50 to 500 microns, are some of the most commercially significant ones, including flat panel displays used in smart phones, tablets, and televisions. Flat panel displays that use inorganic LEDs as pixel level emitters (μILED displays) can offer levels of brightness, transparency, and functionality that are difficult to achieve with other flat panel technologies. Cost-effective production of μILED displays requires techniques for precisely arranging sparse arrays of extremely miniaturized devices on a panel substrate, such as transfer printing with an elastomer stamp. Here we present lab-scale demonstrations of transfer printed μILED displays and the processes used to make them. Demonstrations include passive matrix μILED displays that use conventional off-the shelf drive ASICs and active matrix μILED displays that use miniaturized pixel-level control circuits from CMOS wafers. We present a discussion of key considerations in the design and fabrication of highly miniaturized emitters for μILED displays.
Generation of intermittent gravitocapillary waves via parametric forcing
NASA Astrophysics Data System (ADS)
Castillo, Gustavo; Falcón, Claudio
2018-04-01
We report on the generation of an intermittent wave field driven by a horizontally moving wave maker interacting with Faraday waves. The spectrum of the local gravitocapillary surface wave fluctuations displays a power law in frequency for a wide range of forcing parameters. We compute the probability density function of the local surface height increments, which show that they change strongly across time scales. The structure functions of these increments are shown to display power laws as a function of the time lag, with exponents that are nonlinear functions of the order of the structure function. We argue that the origin of this scale-invariant intermittent spectrum is the Faraday wave pattern breakup due to its advection by the propagating gravity waves. Finally, some interpretations are proposed to explain the appearance of this intermittent spectrum.
5-inch-size liquid crystal flat panel display evaluation test by flight simulator
NASA Astrophysics Data System (ADS)
Kawahara, Hiroyasu; Watanabe, Akira; Wakairo, Kaoru; Udagawa, Tomoyuki; Kurihara, Yoichiro
An evaluation test is conducted on the function, performance, and display format of a 5x5 inch flat panel display (FPD) in a flight simulator. The FPD utilizes a color liquid crystal panel that is compact and lightweight and has excellent visibility. The simulator evaluation test is carried out in sequence with the conventional takeoff and landing to altitude, and then conversion to STOL procedures for flight path and subsequent approach and landing. It is shown that the liquid crystal display could be employed as a satisfactory indicator for aircraft instrumentation.
Incubator Display Software Cost Reduction Toolset Software Requirements Specification
NASA Technical Reports Server (NTRS)
Moran, Susanne; Jeffords, Ralph
2005-01-01
The Incubator Display Software Requirements Specification was initially developed by Intrinsyx Technologies Corporation (Intrinsyx) under subcontract to Lockheed Martin, Contract Number NAS2-02090, for the National Aeronautics and Space Administration (NASA) Ames Research Center (ARC) Space Station Biological Research Project (SSBRP). The Incubator Display is a User Payload Application (UPA) used to control an Incubator subrack payload for the SSBRP. The Incubator Display functions on-orbit as part of the subrack payload laptop, on the ground as part of the Communication and Data System (CDS) ground control system, and also as part of the crew training environment.
Physical evaluation of color and monochrome medical displays using an imaging colorimeter
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Gu, Xiliang; Fan, Jiahua
2013-03-01
This paper presents an approach to physical evaluation of color and monochrome medical grade displays using an imaging colorimeter. The purpose of this study was to examine the influence of medical display types, monochrome or color at the same maximum luminance settings, on diagnostic performance. The focus was on the measurements of physical characteristics including spatial resolution and noise performance, which we believed could affect the clinical performance. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between two EIZO displays.
Optimum viewing distance for target acquisition
NASA Astrophysics Data System (ADS)
Holst, Gerald C.
2015-05-01
Human visual system (HVS) "resolution" (a.k.a. visual acuity) varies with illumination level, target characteristics, and target contrast. For signage, computer displays, cell phones, and TVs a viewing distance and display size are selected. Then the number of display pixels is chosen such that each pixel subtends 1 min-1. Resolution of low contrast targets is quite different. It is best described by Barten's contrast sensitivity function. Target acquisition models predict maximum range when the display pixel subtends 3.3 min-1. The optimum viewing distance is nearly independent of magnification. Noise increases the optimum viewing distance.
New DICOM extensions for softcopy and hardcopy display consistency.
Eichelberg, M; Riesmeier, J; Kleber, K; Grönemeyer, D H; Oosterwijk, H; Jensch, P
2000-01-01
The DICOM standard defines in detail how medical images can be communicated. However, the rules on how to interpret the parameters contained in a DICOM image which deal with the image presentation were either lacking or not well defined. As a result, the same image frequently looks different when displayed on different workstations or printed on a film from various printers. Three new DICOM extensions attempt to close this gap by defining a comprehensive model for the display of images on softcopy and hardcopy devices: Grayscale Standard Display Function, Grayscale Softcopy Presentation State and Presentation Look Up Table.
2012-10-01
VarTech Ruggedized Computer Features The IDVD consisted of a VarTech brand ruggedized computer within a NEMA enclosure (VARTEC VTPC104PHB). Optional...range 9 to 36V Rechargeable Battery Power (10 hrs, 1 month in standby) Gain in Function Resolution 1024 x 768 1024 x 768 Even NEMA Enclosure NEMA ...there is some functionality loss associated with that. The display is not easily readable in the sunlight, it does not have a weatherproof NEMA
Image quality analysis of a color LCD as well as a monochrome LCD using a Foveon color CMOS camera
NASA Astrophysics Data System (ADS)
Dallas, William J.; Roehrig, Hans; Krupinski, Elizabeth A.
2007-09-01
We have combined a CMOS color camera with special software to compose a multi-functional image-quality analysis instrument. It functions as a colorimeter as well as measuring modulation transfer functions (MTF) and noise power spectra (NPS). It is presently being expanded to examine fixed-pattern noise and temporal noise. The CMOS camera has 9 μm square pixels and a pixel matrix of 2268 x 1512 x 3. The camera uses a sensor that has co-located pixels for all three primary colors. We have imaged sections of both a color and a monochrome LCD monitor onto the camera sensor with LCD-pixel-size to camera-pixel-size ratios of both 12:1 and 17.6:1. When used as an imaging colorimeter, each camera pixel is calibrated to provide CIE color coordinates and tristimulus values. This capability permits the camera to simultaneously determine chromaticity in different locations on the LCD display. After the color calibration with a CS-200 colorimeter the color coordinates of the display's primaries determined from the camera's luminance response are very close to those found from the CS-200. Only the color coordinates of the display's white point were in error. For calculating the MTF a vertical or horizontal line is displayed on the monitor. The captured image is color-matrix preprocessed, Fourier transformed then post-processed. For NPS, a uniform image is displayed on the monitor. Again, the image is pre-processed, transformed and processed. Our measurements show that the horizontal MTF's of both displays have a larger negative slope than that of the vertical MTF's. This behavior indicates that the horizontal MTF's are poorer than the vertical MTF's. However the modulations at the Nyquist frequency seem lower for the color LCD than for the monochrome LCD. The spatial noise of the color display in both directions is larger than that of the monochrome display. Attempts were also made to analyze the total noise in terms of spatial and temporal noise by applying subtractions of images taken at exactly the same exposure. Temporal noise seems to be significantly lower than spatial noise.
An interactive graphics program for manipulation and display of panel method geometry
NASA Technical Reports Server (NTRS)
Hall, J. F.; Neuhart, D. H.; Walkley, K. B.
1983-01-01
Modern aerodynamic panel methods that handle large, complex geometries have made evident the need to interactively manipulate, modify, and view such configurations. With this purpose in mind, the GEOM program was developed. It is a menu driven, interactive program that uses the Tektronix PLOT 10 graphics software to display geometry configurations which are characterized by an abutting set of networks. These networks are composed of quadrilateral panels which are described by the coordinates of their corners. GEOM is divided into fourteen executive controlled functions. These functions are used to build configurations, scale and rotate networks, transpose networks defining M and N lines, graphically display selected networks, join and split networks, create wake networks, produce symmetric images of networks, repanel and rename networks, display configuration cross sections, and output network geometry in two formats. A data base management system is used to facilitate data transfers in this program. A sample session illustrating various capabilities of the code is included as a guide to program operation.
Performance, physiological, and oculometer evaluation of VTOL landing displays
NASA Technical Reports Server (NTRS)
North, R. A.; Stackhouse, S. P.; Graffunder, K.
1979-01-01
A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Physiological, visual response, and conventional flight performance measures were recorded for landing approaches performed in the NASA Visual Motion Simulator (VMS). Three displays (two computer graphic and a conventional flight director), three crosswind amplitudes, and two motion base conditions (fixed vs. moving base) were tested in a factorial design. Multivariate discriminant functions were formed from flight performance and/or visual response variables. The flight performance variable discriminant showed maximum differentation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus represent higher workload levels.
Spreadsheet Works: Graphing Functions on a Spreadsheet.
ERIC Educational Resources Information Center
Ramamurthi, V. S.
1989-01-01
Explains graphing functions when using LOTUS 1-2-3. Provides examples and explains keystroke entries needed to make the graphs. Notes up to six functions can be displayed on the same set of axes. (MVL)
Assessment of OLED displays for vision research.
Cooper, Emily A; Jiang, Haomiao; Vildavski, Vladimir; Farrell, Joyce E; Norcia, Anthony M
2013-10-23
Vision researchers rely on visual display technology for the presentation of stimuli to human and nonhuman observers. Verifying that the desired and displayed visual patterns match along dimensions such as luminance, spectrum, and spatial and temporal frequency is an essential part of developing controlled experiments. With cathode-ray tubes (CRTs) becoming virtually unavailable on the commercial market, it is useful to determine the characteristics of newly available displays based on organic light emitting diode (OLED) panels to determine how well they may serve to produce visual stimuli. This report describes a series of measurements summarizing the properties of images displayed on two commercially available OLED displays: the Sony Trimaster EL BVM-F250 and PVM-2541. The results show that the OLED displays have large contrast ratios, wide color gamuts, and precise, well-behaved temporal responses. Correct adjustment of the settings on both models produced luminance nonlinearities that were well predicted by a power function ("gamma correction"). Both displays have adjustable pixel independence and can be set to have little to no spatial pixel interactions. OLED displays appear to be a suitable, or even preferable, option for many vision research applications.
McFadd, Emily; Wilkinson, Krista
2010-06-01
For children with complex communication needs, augmentative and alternative communication (AAC) devices offer a functional way to communicate thoughts and feelings. Despite many significant advances in the field, effective and efficient aided communication can remain a challenge for some clients and their partners. One critical element of aided AAC intervention is systematic attention to the design of the communication display itself. A well-designed display will foster communication outcomes; a poorly designed one might have the opposite effect. Surprisingly, to our knowledge there are no studies of the strategies that clinicians actually employ when putting together a display. In this research note, we examine, on a case-by-case basis, the strategies six clinicians used when constructing display pages, as a means of highlighting potential areas that might warrant systematic research on display design.
Functional cell-surface display of a lipase-specific chaperone.
Wilhelm, Susanne; Rosenau, Frank; Becker, Stefan; Buest, Sebastian; Hausmann, Sascha; Kolmar, Harald; Jaeger, Karl-Erich
2007-01-02
Lipases are important enzymes in biotechnology. Extracellular bacterial lipases from Pseudomonads and related species require the assistance of specific chaperones, designated "Lif" proteins (lipase specific foldases). Lifs, a unique family of steric chaperones, are anchored to the periplasmic side of the inner membrane where they convert lipases into their active conformation. We have previously shown that the autotransporter protein EstA from P. aeruginosa can be used to direct a variety of proteins to the cell surface of Escherichia coli. Here we demonstrate for the first time the functional cell-surface display of the Lif chaperone and FACS (fluorescence-activated cell sorting)-based analysis of bacterial cells that carried foldase-lipase complexes. The model Lif protein, LipH from P. aeruginosa, was displayed at the surface of E. coli cells. Surface exposed LipH was functional and efficiently refolded chemically denatured lipase. The foldase autodisplay system reported here can be used for a variety of applications including the ultrahigh-throughput screening of large libraries of foldase variants generated by directed evolution.
Method and system for monitoring and displaying engine performance parameters
NASA Technical Reports Server (NTRS)
Abbott, Terence S. (Inventor); Person, Jr., Lee H. (Inventor)
1991-01-01
The invention is a method and system for monitoring and directly displaying the actual thrust produced by a jet aircraft engine under determined operating conditions and the available thrust and predicted (commanded) thrust of a functional model of an ideal engine under the same determined operating conditions. A first set of actual value output signals representative of a plurality of actual performance parameters of the engine under the determined operating conditions is generated and compared with a second set of predicted value output signals representative of the predicted value of corresponding performance parameters of a functional model of the engine under the determined operating conditions to produce a third set of difference value output signals within a range of normal, caution, or warning limit values. A thrust indicator displays when any one of the actual value output signals is in the warning range while shaping function means shape each of the respective difference output signals as each approaches the limit of the respective normal, caution, and warning range limits.
Fab is the most efficient format to express functional antibodies by yeast surface display.
Sivelle, Coline; Sierocki, Raphaël; Ferreira-Pinto, Kelly; Simon, Stéphanie; Maillere, Bernard; Nozach, Hervé
2018-04-30
Multiple formats are available for engineering of monoclonal antibodies (mAbs) by yeast surface display, but they do not all lead to efficient expression of functional molecules. We therefore expressed four anti-tumor necrosis factor and two anti-IpaD mAbs as single-chain variable fragment (scFv), antigen-binding fragment (Fab) or single-chain Fabs and compared their expression levels and antigen-binding efficiency. Although the scFv and scFab formats are widely used in the literature, 2 of 6 antibodies were either not or weakly expressed. In contrast, all 6 antibodies expressed as Fab revealed strong binding and high affinity, comparable to that of the soluble form. We also demonstrated that the variations in expression did not affect Fab functionality and were due to variations in light chain display and not to misfolded dimers. Our results suggest that Fab is the most versatile format for the engineering of mAbs.
An examination of OLED display application to military equipment
NASA Astrophysics Data System (ADS)
Thomas, J.; Lorimer, S.
2010-04-01
OLED display technology has developed sufficiently to support small format commercial applications such as cell-phone main display functions. Revenues seem sufficient to finance both performance improvements and to develop new applications. The situation signifies the possibility that OLED technology is on the threshold of credibility for military applications. This paper will examine both performance and some possible applications for the military ground mobile environment, identifying the advantages and disadvantages of this promising new technology.
Application of industrial robots in automatic disassembly line of waste LCD displays
NASA Astrophysics Data System (ADS)
Wang, Sujuan
2017-11-01
In the automatic disassembly line of waste LCD displays, LCD displays are disassembled into plastic shells, metal shields, circuit boards, and LCD panels. Two industrial robots are used to cut metal shields and remove circuit boards in this automatic disassembly line. The functions of these two industrial robots, and the solutions to the critical issues of model selection, the interfaces with PLCs and the workflows were described in detail in this paper.
OLED displays in a ground-mobile application
NASA Astrophysics Data System (ADS)
Thomas, J.; Lorimer, S.
2008-04-01
OLED technology has matured sufficiently to consider it a realistic candidate for military display applications. Manufacturing sources are transitioning from an early developer to a business focused and often rationalised supply base that already has a sustainable business model. New commercial products, with a growing list of applications are slowly swelling the list of available OLED display components that can be considered for military requirements. This paper describes an exploratory application of OLED technology to the Towed Artillery Digitisation (TAD) programme. The Gunners Display function in this system endures the most difficult environment available in Army programmes. By replicating the Gunners Display, we have confirmed that OLED technology is compatible with and technically almost ready for rugged military applications using newly available commercial sources.
NASA Technical Reports Server (NTRS)
Dodson, D. W.; Shields, N. L., Jr.
1978-01-01
The Experiment Computer Operating System (ECOS) of the Spacelab will allow the onboard Payload Specialist to command experiment devices and display information relative to the performance of experiments. Three candidate ECOS command and control service concepts were reviewed and laboratory data on operator performance was taken for each concept. The command and control service concepts evaluated included a dedicated operator's menu display from which all command inputs were issued, a dedicated command key concept with which command inputs could be issued from any display, and a multi-display concept in which command inputs were issued from several dedicated function displays. Advantages and disadvantages are discussed in terms of training, operational errors, task performance time, and subjective comments of system operators.
[Microcomputer control of a LED stimulus display device].
Ohmoto, S; Kikuchi, T; Kumada, T
1987-02-01
A visual stimulus display system controlled by a microcomputer was constructed at low cost. The system consists of a LED stimulus display device, a microcomputer, two interface boards, a pointing device (a "mouse") and two kinds of software. The first software package is written in BASIC. Its functions are: to construct stimulus patterns using the mouse, to construct letter patterns (alphabet, digit, symbols and Japanese letters--kanji, hiragana, katakana), to modify the patterns, to store the patterns on a floppy disc, to translate the patterns into integer data which are used to display the patterns in the second software. The second software package, written in BASIC and machine language, controls display of a sequence of stimulus patterns in predetermined time schedules in visual experiments.
Groves, Maria AT; Amanuel, Lily; Campbell, Jamie I; Rees, D Gareth; Sridharan, Sudharsan; Finch, Donna K; Lowe, David C; Vaughan, Tristan J
2014-01-01
In vitro selection technologies are an important means of affinity maturing antibodies to generate the optimal therapeutic profile for a particular disease target. Here, we describe the isolation of a parent antibody, KENB061 using phage display and solution phase selections with soluble biotinylated human IL-1R1. KENB061 was affinity matured using phage display and targeted mutagenesis of VH and VL CDR3 using NNS randomization. Affinity matured VHCDR3 and VLCDR3 library blocks were recombined and selected using phage and ribosome display protocol. A direct comparison of the phage and ribosome display antibodies generated was made to determine their functional characteristics. PMID:24256948
Ciric, Milica; Moon, Christina D; Leahy, Sinead C; Creevey, Christopher J; Altermann, Eric; Attwood, Graeme T; Rakonjac, Jasna; Gagic, Dragana
2014-05-12
In silico, secretome proteins can be predicted from completely sequenced genomes using various available algorithms that identify membrane-targeting sequences. For metasecretome (collection of surface, secreted and transmembrane proteins from environmental microbial communities) this approach is impractical, considering that the metasecretome open reading frames (ORFs) comprise only 10% to 30% of total metagenome, and are poorly represented in the dataset due to overall low coverage of metagenomic gene pool, even in large-scale projects. By combining secretome-selective phage display and next-generation sequencing, we focused the sequence analysis of complex rumen microbial community on the metasecretome component of the metagenome. This approach achieved high enrichment (29 fold) of secreted fibrolytic enzymes from the plant-adherent microbial community of the bovine rumen. In particular, we identified hundreds of heretofore rare modules belonging to cellulosomes, cell-surface complexes specialised for recognition and degradation of the plant fibre. As a method, metasecretome phage display combined with next-generation sequencing has a power to sample the diversity of low-abundance surface and secreted proteins that would otherwise require exceptionally large metagenomic sequencing projects. As a resource, metasecretome display library backed by the dataset obtained by next-generation sequencing is ready for i) affinity selection by standard phage display methodology and ii) easy purification of displayed proteins as part of the virion for individual functional analysis.
NASA Astrophysics Data System (ADS)
Rousson, Johanna; Haar, Jérémy; Santal, Sarah; Kumcu, Asli; Platiša, Ljiljana; Piepers, Bastian; Kimpe, Tom; Philips, Wilfried
2016-03-01
While three-dimensional (3-D) imaging systems are entering hospitals, no study to date has explored the luminance calibration needs of 3-D stereoscopic diagnostic displays and if they differ from two-dimensional (2-D) displays. Since medical display calibration incorporates the human contrast sensitivity function (CSF), we first assessed the 2-D CSF for benchmarking and then examined the impact of two image parameters on the 3-D stereoscopic CSF: (1) five depth plane (DP) positions (between DP: -171 and DP: 2853 mm), and (2) three 3-D inclinations (0 deg, 45 deg, and 60 deg around the horizontal axis of a DP). Stimuli were stereoscopic images of a vertically oriented 2-D Gabor patch at one of seven frequencies ranging from 0.4 to 10 cycles/deg. CSFs were measured for seven to nine human observers with a staircase procedure. The results indicate that the 2-D CSF model remains valid for a 3-D stereoscopic display regardless of the amount of disparity between the stereo images. We also found that the 3-D CSF at DP≠0 does not differ from the 3-D CSF at DP=0 for DPs and disparities which allow effortless binocular fusion. Therefore, the existing 2-D medical luminance calibration algorithm remains an appropriate tool for calibrating polarized stereoscopic medical displays.
Evaluation of tablet computers for visual function assessment.
Bodduluri, Lakshmi; Boon, Mei Ying; Dain, Stephen J
2017-04-01
Recent advances in technology and the increased use of tablet computers for mobile health applications such as vision testing necessitate an understanding of the behavior of the displays of such devices, to facilitate the reproduction of existing or the development of new vision assessment tests. The purpose of this study was to investigate the physical characteristics of one model of tablet computer (iPad mini Retina display) with regard to display consistency across a set of devices (15) and their potential application as clinical vision assessment tools. Once the tablet computer was switched on, it required about 13 min to reach luminance stability, while chromaticity remained constant. The luminance output of the device remained stable until a battery level of 5%. Luminance varied from center to peripheral locations of the display and with viewing angle, whereas the chromaticity did not vary. A minimal (1%) variation in luminance was observed due to temperature, and once again chromaticity remained constant. Also, these devices showed good temporal stability of luminance and chromaticity. All 15 tablet computers showed gamma functions approximating the standard gamma (2.20) and showed similar color gamut sizes, except for the blue primary, which displayed minimal variations. The physical characteristics across the 15 devices were similar and are known, thereby facilitating the use of this model of tablet computer as visual stimulus displays.
NASA Technical Reports Server (NTRS)
Edmonds, Karina
2008-01-01
This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.
Ullah, Mujeeb; Armin, Ardalan; Tandy, Kristen; Yambem, Soniya D.; Burn, Paul L.; Meredith, Paul; Namdas, Ebinazar B.
2015-01-01
Light-emitting field effect transistors (LEFETs) are an emerging class of multifunctional optoelectronic devices. It combines the light emitting function of an OLED with the switching function of a transistor in a single device architecture. The dual functionality of LEFETs has the potential applications in active matrix displays. However, the key problem of existing LEFETs thus far has been their low EQEs at high brightness, poor ON/OFF and poorly defined light emitting area - a thin emissive zone at the edge of the electrodes. Here we report heterostructure LEFETs based on solution processed unipolar charge transport and an emissive polymer that have an EQE of up to 1% at a brightness of 1350 cd/m2, ON/OFF ratio > 104 and a well-defined light emitting zone suitable for display pixel design. We show that a non-planar hole-injecting electrode combined with a semi-transparent electron-injecting electrode enables to achieve high EQE at high brightness and high ON/OFF ratio. Furthermore, we demonstrate that heterostructure LEFETs have a better frequency response (fcut-off = 2.6 kHz) compared to single layer LEFETs. The results presented here therefore are a major step along the pathway towards the realization of LEFETs for display applications. PMID:25743444
Zar, Harvey A; Noe, Frances E; Szalados, James E; Goodrich, Michael D; Busby, Michael G
2002-01-01
A repetitive graphic display of the single breath pulmonary function can indicate changes in cardiac and pulmonary physiology brought on by clinical events. Parallel advances in computer technology and monitoring make real-time, single breath pulmonary function clinically practicable. We describe a system built from a commercially available airway gas monitor and off the shelf computer and data-acquisition hardware. Analog data for gas flow rate, O2, and CO2 concentrations are introduced into a computer through an analog-to-digital conversion board. Oxygen uptake (VO2) and carbon dioxide output (VCO2) are calculated for each breath. Inspired minus expired concentrations for O2 and CO2 are displayed simultaneously with the expired gas flow rate curve for each breath. Dead-space and alveolar ventilation are calculated for each breath and readily appreciated from the display. Graphs illustrating the function of the system are presented for the following clinical scenarios; upper airway obstruction, bronchospasm, bronchopleural fistula, pulmonary perfusion changes and inadequate oxygen delivery. This paper describes a real-time, single breath pulmonary monitoring system that displays three parameters graphed against time: expired flow rate, oxygen uptake and carbon dioxide production. This system allows for early and rapid recognition of treatable conditions that may lead to adverse events without any additional patient measurements or invasive procedures. Monitoring systems similar to the one described in this paper may lead to a higher level of patient safety without any additional patient risk.
Use of Peer-Mediated Intervention in Children with Attention Deficit Hyperactivity Disorder
ERIC Educational Resources Information Center
Grauvogel-MacAleese, Alicia N.; Wallace, Michele D.
2010-01-01
The present experiment extended and replicated the use of functional analysis and a peer-mediated intervention to decrease disruptive behavior displayed by children diagnosed with attention deficit hyperactivity disorder in an afterschool program. After determining that the participants displayed off-task behavior maintained by peer attention via…
JSXGraph--Dynamic Mathematics with JavaScript
ERIC Educational Resources Information Center
Gerhauser, Michael; Valentin, Bianca; Wassermann, Alfred
2010-01-01
Since Java applets seem to be on the retreat in web application, other approaches for displaying interactive mathematics in the web browser are needed. One such alternative could be our open-source project JSXGraph. It is a cross-browser library for displaying interactive geometry, function plotting, graphs, and data visualization in a web…
Implications of Windowing Techniques for CAI.
ERIC Educational Resources Information Center
Heines, Jesse M.; Grinstein, Georges G.
This paper discusses the use of a technique called windowing in computer assisted instruction to allow independent control of functional areas in complex CAI displays and simultaneous display of output from a running computer program and coordinated instructional material. Two obstacles to widespread use of CAI in computer science courses are…
The Magic Ear: Another Approach to Automated Classroom Control.
ERIC Educational Resources Information Center
George, James R., III; And Others
"Excessive" noise outburst behavior of 24 second graders was effectively controlled under automated stimulus conditions. A voice operated relay transmitted signals to an automated combination light display and outburst time/total running time meters; under 2 conditions, the light display functioned first as a primary, then as a secondary…
Documentation: Ideas and Applications from the Reggio Emilia Approach
ERIC Educational Resources Information Center
Schroeder-Yu, Gigi
2008-01-01
Teachers of the visual arts have long considered the importance of how to collect and display their students' work. Throughout history, bulletin boards have covered classrooms and school hallways neatly displaying children's art work. This article briefly summarizes how documentation functions within the Reggio Emilia approach and then discusses…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fries, Samuel B.; French, Shelane
2014-10-01
These Drupal Modules extend the functionality of Drupal by including specific styles for dates and tabs, publishing options for scheduled and immediate publication of content modes, field visibility in content forms, keyword block filters (taxonomy based), adding content nodes to a specified queue for display in views, and status display of workflow settings.
14 CFR 105.19 - Parachute operations between sunset and sunrise.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES PARACHUTE OPERATIONS Operating Rules § 105.19... between sunset and sunrise, unless the person or object descending from the aircraft displays a light that... be displayed from the time that the person or object is under a properly functioning open parachute...
Fenning, Rachel M; Baker, Jason K; Baker, Bruce L; Crnic, Keith A
2014-06-01
A previous study suggested that mothers of 5-year-old children with borderline intellectual functioning displayed lower positive engagement with their children as compared with both mothers of typically developing children and mothers of children with significant developmental delays (Fenning, Baker, Baker, & Crnic, 2007). The current study integrated father data and followed these families over the subsequent 1-year period. Parent and child behavior were coded from naturalistic home observations at both waves. Results revealed that mothers of children with borderline intellectual functioning displayed a greater increase in negative-controlling parenting from child age 5 to 6 than did other mothers; fathers displayed more negative-controlling behavior in comparison to fathers of typically developing children. In addition, children with borderline intellectual functioning themselves exhibited a more significant escalation in difficult behavior than did typically developing children. Cross-lagged analyses for the sample as a whole indicated that maternal negative-controlling behavior predicted subsequent child difficulties, whereas negative paternal behavior was predicted by earlier child behavior. In conjunction with evidence from Fenning et al. (2007), these findings suggest a complex, dynamic, and systemic developmental pattern in the emotional behavior of families of children with borderline intellectual functioning. Implications and areas in need of additional research are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Shehu, Dayyabu; Alias, Zazali
2018-05-19
Glutathione S-transferases (GSTs) are a family of enzymes that function in the detoxification of variety of electrophilic substrates. In the present work, we report a novel zeta-like GST (designated as KKSG9) from the biphenyl/polychlorobiphenyl degrading organism Acidovorax sp. KKS102. KKSG9 possessed low sequence similarity but similar biochemical properties to zeta class GSTs. Functional analysis showed that the enzyme exhibits wider substrate specificity compared to most zeta class GSTs by reacting with 1-chloro-2,4-dinitrobenzene (CDNB), p-nitrobenzyl chloride (NBC), ethacrynic acid (EA), hydrogen peroxide, and cumene hydroperoxide. The enzyme also displayed dehalogenation function against dichloroacetate, permethrin, and dieldrin. The functional role of Tyr12 was also investigated by site-directed mutagenesis. The mutant (Y12C) displayed low catalytic activity and dehalogenation function against all the substrates when compared with the wild type. Kinetic analysis using NBC and GSH as substrates showed that the mutant (Y12C) displayed a higher affinity for NBC when compared with the wild type, however, no significant change in GSH affinity was observed. These findings suggest that the presence of tyrosine residue in the motif might represent an evolutionary trend toward improving the catalytic activity of the enzyme. The enzyme as well could be useful in the bioremediation of various types of organochlorine pollutants.
NASA Technical Reports Server (NTRS)
1975-01-01
Flow charts and display formats for the simulation of five experiments are given. The experiments are: (1) electromagnetic wave transmission; (2) passive observations of ambient plasma; (3) ionospheric measurements with subsatellite; (4) electron accelerator beam measurements; and (5) measurement of acoustical gravity waves in the sodium layer using lasers. A detailed explanation of the simulation procedure, definition of variables, and an explanation of how the experimenter makes display choices is also presented. A functional description is included on each flow chart and the assumptions and definitions of terms and scope of the flow charts and displays are presented.
Review of fluorescence guided surgery visualization and overlay techniques
Elliott, Jonathan T.; Dsouza, Alisha V.; Davis, Scott C.; Olson, Jonathan D.; Paulsen, Keith D.; Roberts, David W.; Pogue, Brian W.
2015-01-01
In fluorescence guided surgery, data visualization represents a critical step between signal capture and display needed for clinical decisions informed by that signal. The diversity of methods for displaying surgical images are reviewed, and a particular focus is placed on electronically detected and visualized signals, as required for near-infrared or low concentration tracers. Factors driving the choices such as human perception, the need for rapid decision making in a surgical environment, and biases induced by display choices are outlined. Five practical suggestions are outlined for optimal display orientation, color map, transparency/alpha function, dynamic range compression, and color perception check. PMID:26504628
NASA Technical Reports Server (NTRS)
Fern, Lisa Carolynn
2017-01-01
The primary activity for the UAS-NAS Human Systems Integration (HSI) sub-project in Phase 1 was support of RTCA Special Committee 228 Minimum Operational Performance Standards (MOPS). We provide data on the effect of various Detect and Avoid (DAA) display features with respect to pilot performance of the remain well clear function in order to determine the minimum requirements for DAA displays.
NASA Technical Reports Server (NTRS)
1990-01-01
A review is presented of the literature concerning control and display technology that is applicable to the Orbital Maneuvering Vehicle (OMV), a system being developed by NASA that will enable the user to remotely pilot it during a mission in space. In addition to the general review, special consideration is given to virtual image displays and their potential for use in the system, and a preliminary partial task analysis of the user's functions is also presented.
Portable neutron spectrometer and dosimeter
Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.
The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.
Portable neutron spectrometer and dosimeter
Waechter, David A.; Erkkila, Bruce H.; Vasilik, Dennis G.
1985-01-01
The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.
Real-Time Acquisition and Display of Data and Video
NASA Technical Reports Server (NTRS)
Bachnak, Rafic; Chakinarapu, Ramya; Garcia, Mario; Kar, Dulal; Nguyen, Tien
2007-01-01
This paper describes the development of a prototype that takes in an analog National Television System Committee (NTSC) video signal generated by a video camera and data acquired by a microcontroller and display them in real-time on a digital panel. An 8051 microcontroller is used to acquire power dissipation by the display panel, room temperature, and camera zoom level. The paper describes the major hardware components and shows how they are interfaced into a functional prototype. Test data results are presented and discussed.
Control/display trade-off study for single-pilot instrument flight rule operations
NASA Technical Reports Server (NTRS)
Hoh, R.
1983-01-01
The objectives were to determine minimum autopilot functions and displays required to keep pilot workload at an acceptable level; to determine what constitutes an acceptable level of workload; to identify critical tasks; and to suggest specific experiments required to refine conclusions. It was determined that workload relief is derived from basic stability augmentation; that complex autopilots can lead to serious blunders; and that displays need to enhance positional awareness and minimize the likelihood of false hypothesis.
Raster graphics display library
NASA Technical Reports Server (NTRS)
Grimsrud, Anders; Stephenson, Michael B.
1987-01-01
The Raster Graphics Display Library (RGDL) is a high level subroutine package that give the advanced raster graphics display capabilities needed. The RGDL uses FORTRAN source code routines to build subroutines modular enough to use as stand-alone routines in a black box type of environment. Six examples are presented which will teach the use of RGDL in the fastest, most complete way possible. Routines within the display library that are used to produce raster graphics are presented in alphabetical order, each on a separate page. Each user-callable routine is described by function and calling parameters. All common blocks that are used in the display library are listed and the use of each variable within each common block is discussed. A reference on the include files that are necessary to compile the display library is contained. Each include file and its purpose are listed. The link map for MOVIE.BYU version 6, a general purpose computer graphics display system that uses RGDL software, is also contained.
A candidate concept for display of forward-looking wind shear information
NASA Technical Reports Server (NTRS)
Hinton, David A.
1989-01-01
A concept is proposed which integrates forward-look wind shear information with airplane performance capabilities to predict future airplane energy state as a function of range. The information could be displayed to a crew either in terms of energy height or airspeed deviations. The anticipated benefits of the proposed display information concept are: (1) a wind shear hazard product that scales directly to the performance impact on the airplane and that has intuitive meaning to flight crews; (2) a reduction in flight crew workload by automatic processing of relevant hazard parameters; and (3) a continuous display of predicted airplane energy state if the approach is continued. Such a display may be used to improve pilot situational awareness or improve pilot confidence in wind shear alerts generated by other systems. The display is described and the algorithms necessary for implementation in a simulation system are provided.
Simultaneous display of two large proteins on the head and tail of bacteriophage lambda.
Pavoni, Emiliano; Vaccaro, Paola; D'Alessio, Valeria; De Santis, Rita; Minenkova, Olga
2013-09-30
Consistent progress in the development of bacteriophage lambda display platform as an alternative to filamentous phage display system was achieved in the recent years. The lambda phage has been engineered to display efficiently multiple copies of peptides or even large protein domains providing a powerful tool for screening libraries of peptides, proteins and cDNA. In the present work we describe an original method for dual display of large proteins on the surface of lambda particles. An anti-CEA single-chain antibody fragment and green fluorescent protein or alkaline phosphatase were simultaneously displayed by engineering both gpD and gpV lambda proteins. Here we show that such modified phage particles can be used for the detection of target molecules in vitro and in vivo. Dual expression of functional moieties on the surface of the lambda phage might open the way to generation of a new class of diagnostic and therapeutic targeted nanoparticles.
Local processes in preattentive feature detection.
Bacon, W F; Egeth, H E
1991-02-01
Sagi and Julesz (1987) claimed that for a target to be detected preattentively, it must be within some small critical distance of a nontarget. The independent effects of separation and display size, which were confounded in the Sagi and Julesz experiments, were examined. Experiments 1 and 2 revealed that in tasks requiring search for a color-defined target, target-nontarget separation had no effect on reaction time (RT). Display size, however, was inversely related to RT. Experiment 3 ruled out the possibility that the decreasing function of RT with display size was due to arousal caused by higher display luminance. When nontarget grouping was inhibited, (Exp. 4) it was found that RT no longer decreased with increasing display size. This suggests that nontarget grouping may have been the cause of the improved performance at larger display sizes. Experiments 5 and 6 extended the results to line segments, the stimuli used by Sagi and Julesz.
Tran, Thanh; Guardigni, Viola; Pencina, Karol M; Amato, Anthony A; Floyd, Michael; Brawley, Brooke; Mozeleski, Brian; McKinnon, Jennifer; Woodbury, Erin; Heckel, Emily; Li, Zhuoying; Storer, Tom; Sax, Paul E; Montano, Monty
2018-06-01
Human immunodeficiency virus (HIV)-infected individuals are at increased risk of age-associated functional impairment, even with effective antiretroviral therapy (ART). A concurrent characterization of skeletal muscle, physical function, and immune phenotype in aviremic middle-aged HIV-infected adults represents a knowledge gap in prognostic biomarker discovery. We undertook a prospective observational study of 170 middle-aged, HIV-infected ambulatory men and women with CD4+ T-cell counts of at least 350/µL and undetectable plasma viremia while on effective ART, and uninfected control participants. We measured biomarkers for inflammation and immune activation, fatigue, the Veterans Aging Cohort Study mortality index, and physical function. A subset also received a skeletal muscle biopsy and computed tomography scan. Compared to the uninfected participants, HIV-infected participants displayed increased immune activation (P < .001), inflammation (P = .001), and fatigue (P = .010), and in a regression model adjusting for age and sex displayed deficits in stair-climb power (P < .001), gait speed (P = .036), and predicted metabolic equivalents (P = .019). Skeletal muscle displayed reduced nuclear peroxisome proliferator-activated receptor-γ coactivator 1α-positive myonuclei (P = .006), and increased internalized myonuclei (P < .001) that correlated with immune activation (P = .003) and leukocyte infiltration (P < .001). Internalized myonuclei improved a model for HIV discrimination, increasing the C-statistic from 0.84 to 0.90. Asymptomatic HIV-infected middle-aged adults display atypical skeletal muscle profiles, subclinical deficits in physical function, and persistent inflammation and immune activation. Identifying biomarker profiles for muscle dysregulation and risk for future functional decline in the HIV-infected population will be key to developing and monitoring preventive interventions. NCT03011957.
Jensen, Leonardo; Neri, Elida; Bassaneze, Vinicius; De Almeida Oliveira, Nathalia C; Dariolli, Rafael; Turaça, Lauro T; Levy, Débora; Veronez, Douglas; Ferraz, Mariana S A; Alencar, Adriano M; Bydlowski, Sérgio P; Cestari, Idágene A; Krieger, José Eduardo
2018-07-01
Neonatal cardiomyocytes are instrumental for disease modeling, but the effects of different cell extraction methods on basic cell biological processes remain poorly understood. We assessed the influence of two popular methods to extract rat neonatal cardiomyocytes, Pre-plating (PP), and Percoll (PC) on cell structure, metabolism, and function. Cardiomyocytes obtained from PP showed higher gene expression for troponins, titin, and potassium and sodium channels compared to PC. Also, PP cells displayed higher levels of troponin I protein. Cells obtained from PC displayed higher lactate dehydrogenase activity and lactate production than PP cells, indicating higher anaerobic metabolism after 8 days of culture. In contrast, reactive oxygen species levels were higher in PP cells as indicated by ethidium and hydroxyethidium production. Consistent with these data, protein nitration was higher in PP cells, as well as nitrite accumulation in cell medium. Moreover, PP cells showed higher global intracellular calcium under basal and 1 mM isoprenaline conditions. In a calcium-transient assessment under electrical stimulation (0.5 Hz), PP cells displayed higher calcium amplitude than cardiomyocytes obtained from PC and using a traction force microscope technique we observed that PP cardiomyocytes showed the highest relaxation. Collectively, we demonstrated that extraction methods influence parameters related to cell structure, metabolism, and function. Overall, PP derived cells are more active and mature than PC cells, displaying higher contractile function and generating more reactive oxygen species. On the other hand, PC derived cells display higher anaerobic metabolism, despite comparable high yields from both protocols. © 2017 Wiley Periodicals, Inc.
Guo, Jiaqi; Fang, Wenwen; Welle, Alexander; Feng, Wenqian; Filpponen, Ilari; Rojas, Orlando J; Levkin, Pavel A
2016-12-14
Films comprising nanofibrillated cellulose (NFC) are suitable substrates for flexible devices in analytical, sensor, diagnostic, and display technologies. However, some major challenges in such developments include their high moisture sensitivity and the complexity of current methods available for functionalization and patterning. In this work, we present a facile process for tailoring the surface wettability and functionality of NFC films by a fast and versatile approach. First, the NFC films were coated with a layer of reactive nanoporous silicone nanofilament by polycondensation of trichlorovinylsilane (TCVS). The TCVS afforded reactive vinyl groups, thereby enabling simple UV-induced functionalization of NFC films with various thiol-containing molecules via the photo "click" thiol-ene reaction. Modification with perfluoroalkyl thiols resulted in robust superhydrophobic surfaces, which could then be further transformed into transparent slippery lubricant-infused NFC films that displayed repellency against both aqueous and organic liquids with surface tensions as low as 18 mN·m -1 . Finally, transparent and flexible NFC films incorporated hydrophilic micropatterns by modification with OH, NH 2 , or COOH surface groups, enabling space-resolved superhydrophobic-hydrophilic domains. Flexibility, transparency, patternability, and perfect superhydrophobicity of the produced nanocellulose substrates warrants their application in biosensing, display protection, and biomedical and diagnostics devices.
Identification, display, and use of symmetry elements in atomic and electronic structure models.
Khosrovani, N; Kung, P W; Freeman, C M; Gorman, A M; Kölmel, C M; Levine, S M; Newsam, J M
1999-01-01
Crystallographic symmetry plays an important role in structure determination from diffraction or scattering data, in spectroscopy and in simulations. It is convenient and insightful to integrate the display and use of such symmetry data with data analysis and modeling methods. We outline the integration of a suite of crystallographic algorithms, closely coupled with interactive graphical displays. These include techniques for identifying the unit cell of a solid, for automatically determining space and point group symmetries, for generalized displays of symmetry elements overlaid on structural models, and for construction, editing, and transformation of models subject to symmetry constraints. In addition, electron densities derived from periodic density functional calculations can be symmetrized and displayed with the corresponding symmetry elements. Applications of these various capabilities in crystallographic research are illustrated by topical examples.
Experience and Grouping Effects when Handling Non-Normal Situations
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
2004-01-01
Currently, most of the displays in control rooms can be categorized as status, alerts/procedures, or control screens. With the advent and use of CRTs and the associated computing power available to compute and display information, it is now possible to combine these different elements of information and control onto a single display. An experiment was conducted to determine which, if any, of these functions should be collocated in order to better handle simple anticipated non-normal system events. The results indicated that there are performance benefits and subject preferences to combining all the information onto one screen or combining the status and alert/procedure information onto one screen and placing the controls in another area. The results indicated that operators quickly modify their display preferences to the display configuration most recently used.
Facial Displays Are Tools for Social Influence.
Crivelli, Carlos; Fridlund, Alan J
2018-05-01
Based on modern theories of signal evolution and animal communication, the behavioral ecology view of facial displays (BECV) reconceives our 'facial expressions of emotion' as social tools that serve as lead signs to contingent action in social negotiation. BECV offers an externalist, functionalist view of facial displays that is not bound to Western conceptions about either expressions or emotions. It easily accommodates recent findings of diversity in facial displays, their public context-dependency, and the curious but common occurrence of solitary facial behavior. Finally, BECV restores continuity of human facial behavior research with modern functional accounts of non-human communication, and provides a non-mentalistic account of facial displays well-suited to new developments in artificial intelligence and social robotics. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
T-38 Primary Flight Display Prototyping and HIVE Support Abstract & Summary
NASA Technical Reports Server (NTRS)
Boniface, Andrew
2015-01-01
This fall I worked in EV3 within NASA's Johnson Space Center in The HIVE (Human Integrated Vehicles & Environments). The HIVE is responsible for human in the loop testing, getting new technologies in front of astronauts, operators, and users early in the development cycle to make the interfaces more human friendly. Some projects the HIVE is working on includes user interfaces for future spacecraft, wearables to alert astronauts about important information, and test beds to simulate mock missions. During my internship I created a prototype for T-38 aircraft displays using LabVIEW, learned how to use microcontrollers, and helped out with other small tasks in the HIVE. The purpose of developing a prototype for T-38 Displays in LabVIEW is to analyze functions of the display such as navigation in a cost and time effective manner. The LabVIEW prototypes allow Ellington Field AOD to easily make adjustments to the display before hardcoding the final product. LabVIEW was used to create a user interface for simulation almost identical to the real aircraft display. Goals to begin the T-38 PFD (Primary Flight Display) prototype included creating a T-38 PFD hardware display in a software environment, designing navigation for the menu's, incorporating vertical and horizontal navigation bars, and to add a heading bug for compass controls connected to the HSI (Horizontal Situation Indicator). To get started with the project, measurements of the entire display were taken. This enabled an accurate model of the hardware display to be created. Navigation of menu's required some exploration of different buttons on the display. The T-38 simulator and aircraft were used for examining the display. After one piece of the prototype was finished, another trip of to the simulator took place. This was done until all goals for the prototype were complete. Some possible integration ideas for displays in the near future are autopilot selection, touch screen displays, and crew member preferences. Complete navigation, control, and function customization will be achievable once a display is fully developed. Other than the T-38 prototyping, I spent time learning how to design small circuits and write code for them to function. This was done by adding electronic circuit components to breadboard and microcontroller then writing code to speak to those components through the microcontroller. I went through an Arduino starter kit to build circuits and code software that allowed the hardware to act. This work was planned to assist in a lighting project this fall but another solution was discovered for the lighting project. Other tasks that I assisted with, included hands on work such as mock-up construction/removal, logic analyzer repairs, and soldering with circuits. The unique opportunity to be involved work with NASA has significantly changed my educational and career goals. This opportunity has only opened the door to my career with engineering. I have learned over the span of this internship that I am fascinated by the type of work that NASA does. My desire to work in the aerospace industry has increased immensely. I hope to return to NASA to be more involved in the advancement of science, engineering, and spaceflight. My interests for my future education and career lie in NASA’s work - pioneering the future in space exploration, scientific discovery and aeronautics research.
Assessment of OLED displays for vision research
Cooper, Emily A.; Jiang, Haomiao; Vildavski, Vladimir; Farrell, Joyce E.; Norcia, Anthony M.
2013-01-01
Vision researchers rely on visual display technology for the presentation of stimuli to human and nonhuman observers. Verifying that the desired and displayed visual patterns match along dimensions such as luminance, spectrum, and spatial and temporal frequency is an essential part of developing controlled experiments. With cathode-ray tubes (CRTs) becoming virtually unavailable on the commercial market, it is useful to determine the characteristics of newly available displays based on organic light emitting diode (OLED) panels to determine how well they may serve to produce visual stimuli. This report describes a series of measurements summarizing the properties of images displayed on two commercially available OLED displays: the Sony Trimaster EL BVM-F250 and PVM-2541. The results show that the OLED displays have large contrast ratios, wide color gamuts, and precise, well-behaved temporal responses. Correct adjustment of the settings on both models produced luminance nonlinearities that were well predicted by a power function (“gamma correction”). Both displays have adjustable pixel independence and can be set to have little to no spatial pixel interactions. OLED displays appear to be a suitable, or even preferable, option for many vision research applications. PMID:24155345
Management and display of four-dimensional environmental data sets using McIDAS
NASA Technical Reports Server (NTRS)
Hibbard, William L.; Santek, David; Suomi, Verner E.
1990-01-01
Over the past four years, great strides have been made in the areas of data management and display of 4-D meteorological data sets. A survey was conducted of available and planned 4-D meteorological data sources. The data types were evaluated for their impact on the data management and display system. The requirements were analyzed for data base management generated by the 4-D data display system. The suitability of the existing data base management procedures and file structure were evaluated in light of the new requirements. Where needed, new data base management tools and file procedures were designed and implemented. The quality of the basic 4-D data sets was assured. The interpolation and extrapolation techniques of the 4-D data were investigated. The 4-D data from various sources were combined to make a uniform and consistent data set for display purposes. Data display software was designed to create abstract line graphic 3-D displays. Realistic shaded 3-D displays were created. Animation routines for these displays were developed in order to produce a dynamic 4-D presentation. A prototype dynamic color stereo workstation was implemented. A computer functional design specification was produced based on interactive studies and user feedback.
Recent progress in flexible OLED displays
NASA Astrophysics Data System (ADS)
Hack, Michael G.; Weaver, Michael S.; Mahon, Janice K.; Brown, Julie J.
2001-09-01
Organic light emitting device (OLED) technology has recently been shown to demonstrate excellent performance and cost characteristics for use in numerous flat panel display (FPD) applications. OLED displays emit bright, colorful light with excellent power efficiency, wide viewing angle and video response rates. OLEDs are also demonstrating the requisite environmental robustness for a wide variety of applications. OLED technology is also the first FPD technology with the potential to be highly functional and durable in a flexible format. The use of plastic and other flexible substrate materials offers numerous advantages over commonly used glass substrates, including impact resistance, light weight, thinness and conformability. Currently, OLED displays are being fabricated on rigid substrates, such as glass or silicon wafers. At Universal Display Corporation (UDC), we are developing a new class of flexible OLED displays (FOLEDs). These displays also have extremely low power consumption through the use of electrophosphorescent doped OLEDs. To commercialize FOLED technology, a number of technical issues related to packaging and display processing on flexible substrates need to be addressed. In this paper, we report on our recent results to demonstrate the key technologies that enable the manufacture of power efficient, long-life flexible OLED displays for commercial and military applications.
Rubinstein, M; Mogil, J S; Japón, M; Chan, E C; Allen, R G; Low, M J
1996-04-30
A physiological role for beta-endorphin in endogenous pain inhibition was investigated by targeted mutagenesis of the proopiomelanocortin gene in mouse embryonic stem cells. The tyrosine codon at position 179 of the proopiomelanocortin gene was converted to a premature translational stop codon. The resulting transgenic mice display no overt developmental or behavioral alterations and have a normally functioning hypothalamic-pituitary-adrenal axis. Homozygous transgenic mice with a selective deficiency of beta-endorphin exhibit normal analgesia in response to morphine, indicating the presence of functional mu-opiate receptors. However, these mice lack the opioid (naloxone reversible) analgesia induced by mild swim stress. Mutant mice also display significantly greater nonopioid analgesia in response to cold water swim stress compared with controls and display paradoxical naloxone-induced analgesia. These changes may reflect compensatory upregulation of alternative pain inhibitory mechanisms.
NASA Technical Reports Server (NTRS)
Watson, A. B.; Solomon, J. A.
1997-01-01
Psychophysica is a set of software tools for psychophysical research. Functions are provided for calibrated visual displays, for fitting and plotting of psychometric functions, and for the QUEST adaptive staircase procedure. The functions are written in the Mathematica programming language.
ERIC Educational Resources Information Center
Bullock, Daniel; And Others
1987-01-01
This commentary, written in response to Witelson's work (1987), examines alternative ways of determining how the developmentally stable functional asymmetry (hemispheric specialization) observed in neurologically intact children can be reconciled with the dramatic recovery of function often displayed following unilateral brain damage. (PCB)
The scope of phage display for membrane proteins.
Vithayathil, Rosemarie; Hooy, Richard M; Cocco, Melanie J; Weiss, Gregory A
2011-12-09
Numerous examples of phage display applied to soluble proteins demonstrate the power of the technique for protein engineering, affinity reagent discovery and structure-function studies. Recent reports have expanded phage display to include membrane proteins (MPs). The scope and limitations of MP display remain undefined. Therefore, we report data from the phage display of representative types of membrane-associated proteins including plasma, nuclear, peripheral, single and multipass. The peripheral MP neuromodulin displays robustly with packaging by conventional M13-KO7 helper phage. The monotopic MP Nogo-66 can also display on the phage surface, if packaged by the modified M13-KO7(+) helper phage. The modified phage coat of KO7(+) can better mimic the zwitterionic character of the plasma membrane. Four examples of putatively α-helical, integral MPs failed to express as fusions to an anchoring phage coat protein and therefore did not display on the phage surface. However, the β-barrel MPs ShuA (Shigella heme uptake A) and MOMP (major outer membrane protein), which pass through the membrane 22 and 16 times, respectively, can display surprisingly well on the surfaces of both conventional and KO7(+) phages. The results provide a guide for protein engineering and large-scale mutagenesis enabled by the phage display of MPs. Copyright © 2011 Elsevier Ltd. All rights reserved.
Mu, Xihui; Tong, Zhaoyang; Huang, Qibin; Liu, Bing; Liu, Zhiwei; Hao, Lanqun; Dong, Hua; Zhang, Jinping; Gao, Chuan
2016-01-01
Using the multiple advantages of the ultra-highly sensitive electrochemiluminescence (ECL) technique, Staphylococcus protein A (SPA) functionalized gold-magnetic nanoparticles and phage displayed antibodies, and using gold-magnetic nanoparticles coated with SPA and coupled with a polyclonal antibody (pcAb) as magnetic capturing probes, and Ru(bpy)32+-labeled phage displayed antibody as a specific luminescence probe, this study reports a new way to detect ricin with a highly sensitive and specific ECL immunosensor and amplify specific detection signals. The linear detection range of the sensor was 0.0001~200 µg/L, and the limit of detection (LOD) was 0.0001 µg/L, which is 2500-fold lower than that of the conventional ELISA technique. The gold-magnetic nanoparticles, SPA and Ru(bpy)32+-labeled phage displayed antibody displayed different amplifying effects in the ECL immunosensor and can decrease LOD 3-fold, 3-fold and 20-fold, respectively, compared with the ECL immunosensors without one of the three effects. The integrated amplifying effect can decrease the LOD 180-fold. The immunosensor integrates the unique advantages of SPA-coated gold-magnetic nanoparticles that improve the activity of the functionalized capturing probe, and the amplifying effect of the Ru(bpy)32+-labeled phage displayed antibodies, so it increases specificity, interference-resistance and decreases LOD. It is proven to be well suited for the analysis of trace amounts of ricin in various environmental samples with high recovery ratios and reproducibility. PMID:26927130
Deep Space Network Antenna Logic Controller
NASA Technical Reports Server (NTRS)
Ahlstrom, Harlow; Morgan, Scott; Hames, Peter; Strain, Martha; Owen, Christopher; Shimizu, Kenneth; Wilson, Karen; Shaller, David; Doktomomtaz, Said; Leung, Patrick
2007-01-01
The Antenna Logic Controller (ALC) software controls and monitors the motion control equipment of the 4,000-metric-ton structure of the Deep Space Network 70-meter antenna. This program coordinates the control of 42 hydraulic pumps, while monitoring several interlocks for personnel and equipment safety. Remote operation of the ALC runs via the Antenna Monitor & Control (AMC) computer, which orchestrates the tracking functions of the entire antenna. This software provides a graphical user interface for local control, monitoring, and identification of faults as well as, at a high level, providing for the digital control of the axis brakes so that the servo of the AMC may control the motion of the antenna. Specific functions of the ALC also include routines for startup in cold weather, controlled shutdown for both normal and fault situations, and pump switching on failure. The increased monitoring, the ability to trend key performance characteristics, the improved fault detection and recovery, the centralization of all control at a single panel, and the simplification of the user interface have all reduced the required workforce to run 70-meter antennas. The ALC also increases the antenna availability by reducing the time required to start up the antenna, to diagnose faults, and by providing additional insight into the performance of key parameters that aid in preventive maintenance to avoid key element failure. The ALC User Display (AUD) is a graphical user interface with hierarchical display structure, which provides high-level status information to the operation of the ALC, as well as detailed information for virtually all aspects of the ALC via drill-down displays. The operational status of an item, be it a function or assembly, is shown in the higher-level display. By pressing the item on the display screen, a new screen opens to show more detail of the function/assembly. Navigation tools and the map button allow immediate access to all screens.
Wang, Yiping; Wang, Xin Maggie; Lu, Junyu; Lee, Vincent W.S.; Ye, Qianling; Nguyen, Hanh; Zheng, Guoping; Zhao, Ye; Alexander, Stephen I.; Harris, David C.H.
2015-01-01
Conventional markers of macrophages (Mфs) and dendritic cells (DCs) lack specificity and often overlap, leading to confusion and controversy regarding the precise function of these cells in kidney and other diseases. This study aimed to identify the phenotype and function of renal mononuclear phagocytes (rMPs) expressing key markers of both Mфs and DCs. F4/80+CD11c+ cells accounted for 45% of total rMPs in normal kidneys and in those from mice with Adriamycin nephropathy (AN). Despite expression of the DC marker CD11c, these double-positive rMPs displayed the features of Mфs, including Mф-like morphology, high expression of CD68, CD204, and CD206, and high phagocytic ability but low antigen-presenting ability. F4/80+CD11c+ cells were found in the cortex but not in the medulla of the kidney. In AN, F4/80+CD11c+ cells displayed an M1 Mф phenotype with high expression of inflammatory mediators and costimulatory factors. Adoptive transfer of F4/80+CD11c+ cells separated from diseased kidney aggravated renal injury in AN mice. Furthermore, adoptive transfer of common progenitors revealed that kidney F4/80+CD11c+ cells were derived predominantly from monocytes, but not from pre-DCs. In conclusion, renal F4/80+CD11c+ cells are a major subset of rMPs and display Mф-like phenotypic and functional characteristics in health and in AN. PMID:25012165
Twala, Busisiwe V; Sewell, B Trevor; Jordaan, Justin
2012-05-10
The use of enzymes in industrial applications is limited by their instability, cost and difficulty in their recovery and re-use. Immobilisation is a technique which has been shown to alleviate these limitations in biocatalysis. Here we describe the immobilisation of two biocatalytically relevant co-factor recycling enzymes, glucose dehydrogenase (GDH) and NADH oxidase (NOD) on aldehyde functional ReSyn™ polymer microspheres with varying functional group densities. The successful immobilisation of the enzymes on this new high capacity microsphere technology resulted in the maintenance of activity of ∼40% for GDH and a maximum of 15.4% for NOD. The microsphere variant with highest functional group density of ∼3500 μmol g⁻¹ displayed the highest specific activity for the immobilisation of both enzymes at 33.22 U mg⁻¹ and 6.75 U mg⁻¹ for GDH and NOD with respective loading capacities of 51% (0.51 mg mg⁻¹) and 129% (1.29 mg mg⁻¹). The immobilised GDH further displayed improved activity in the acidic pH range. Both enzymes displayed improved pH and thermal stability with the most pronounced thermal stability for GDH displayed on ReSyn™ A during temperature incubation at 65 °C with a 13.59 fold increase, and NOD with a 2.25-fold improvement at 45 °C on the same microsphere variant. An important finding is the suitability of the microspheres for stabilisation of the multimeric protein GDH. Copyright © 2012 Elsevier Inc. All rights reserved.
Cao, Qi; Wang, Yiping; Wang, Xin Maggie; Lu, Junyu; Lee, Vincent W S; Ye, Qianling; Nguyen, Hanh; Zheng, Guoping; Zhao, Ye; Alexander, Stephen I; Harris, David C H
2015-02-01
Conventional markers of macrophages (Mфs) and dendritic cells (DCs) lack specificity and often overlap, leading to confusion and controversy regarding the precise function of these cells in kidney and other diseases. This study aimed to identify the phenotype and function of renal mononuclear phagocytes (rMPs) expressing key markers of both Mфs and DCs. F4/80(+)CD11c(+) cells accounted for 45% of total rMPs in normal kidneys and in those from mice with Adriamycin nephropathy (AN). Despite expression of the DC marker CD11c, these double-positive rMPs displayed the features of Mфs, including Mф-like morphology, high expression of CD68, CD204, and CD206, and high phagocytic ability but low antigen-presenting ability. F4/80(+)CD11c(+) cells were found in the cortex but not in the medulla of the kidney. In AN, F4/80(+)CD11c(+) cells displayed an M1 Mф phenotype with high expression of inflammatory mediators and costimulatory factors. Adoptive transfer of F4/80(+)CD11c(+) cells separated from diseased kidney aggravated renal injury in AN mice. Furthermore, adoptive transfer of common progenitors revealed that kidney F4/80(+)CD11c(+) cells were derived predominantly from monocytes, but not from pre-DCs. In conclusion, renal F4/80(+)CD11c(+) cells are a major subset of rMPs and display Mф-like phenotypic and functional characteristics in health and in AN. Copyright © 2015 by the American Society of Nephrology.
Dual function conducting polymer diodes
Heeger, Alan J.; Yu, Gang
1996-01-01
Dual function diodes based on conjugated organic polymer active layers are disclosed. When positively biased the diodes function as light emitters. When negatively biased they are highly efficient photodiodes. Methods of preparation and use of these diodes in displays and input/output devices are also disclosed.
Brown, Philip S.; Bhushan, Bharat
2015-01-01
Coatings with specific surface wetting properties are of interest for anti-fouling, anti-fogging, anti-icing, self-cleaning, anti-smudge, and oil-water separation applications. Many previous bioinspired surfaces are of limited use due to a lack of mechanical durability. Here, a layer-by-layer technique is utilized to create coatings with four combinations of water and oil repellency and affinity. An adapted layer-by-layer approach is tailored to yield specific surface properties, resulting in a durable, functional coating. This technique provides necessary flexibility to improve substrate adhesion combined with desirable surface chemistry. Polyelectrolyte binder, SiO2 nanoparticles, and silane or fluorosurfactant layers are deposited, combining surface roughness and necessary chemistry to result in four different coatings: superhydrophilic/superoleophilic, superhydrophobic/superoleophilic, superhydrophobic/superoleophobic, and superhydrophilic/superoleophobic. The superoleophobic coatings display hexadecane contact angles >150° with tilt angles <5°, whilst the superhydrophobic coatings display water contact angles >160° with tilt angles <2°. One coating combines both oleophobic and hydrophobic properties, whilst others mix and match oil and water repellency and affinity. Coating durability was examined through the use of micro/macrowear experiments. These coatings display transparency acceptable for some applications. Fabrication via this novel combination of techniques results in durable, functional coatings displaying improved performance compared to existing work where either durability or functionality is compromised. PMID:26353971
Astor-Stetson, E; Lane, S
1991-08-01
Reflectance contrast (i.e., black as compared to grey figures on white ground) and display illumination were manipulated to vary the brightness contrast of Wundt-Hering figures. 16 college students and 16 older adults were presented with high, medium, and low reflectance contrast figures. For half the participants, display illumination was manipulated by covering the figures with a .5 yellow neutral density filter. Magnitude of the illusion increased significantly with increased reflectance contrast for college students, and college students were significantly more susceptible to the high contrast figures than were older adults. Display illumination had no effect on the performance of either group.
Alarm guided critical function and success path monitoring
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1994-01-01
The use of alarm indication on the overview (IPSO) display to initiate diagnosis of challenges to critical functions or unavailability of success paths, and further alarm-based guidance toward ultimate diagnosis.
Team members' emotional displays as indicators of team functioning.
Homan, Astrid C; Van Kleef, Gerben A; Sanchez-Burks, Jeffrey
2016-01-01
Emotions are inherent to team life, yet it is unclear how observers use team members' emotional expressions to make sense of team processes. Drawing on Emotions as Social Information theory, we propose that observers use team members' emotional displays as a source of information to predict the team's trajectory. We argue and show that displays of sadness elicit more pessimistic inferences regarding team dynamics (e.g., trust, satisfaction, team effectiveness, conflict) compared to displays of happiness. Moreover, we find that this effect is strengthened when the future interaction between the team members is more ambiguous (i.e., under ethnic dissimilarity; Study 1) and when emotional displays can be clearly linked to the team members' collective experience (Study 2). These studies shed light on when and how people use others' emotional expressions to form impressions of teams.
NASA Astrophysics Data System (ADS)
Venter, Petrus J.; Bogalecki, Alfons W.; du Plessis, Monuko; Goosen, Marius E.; Nell, Ilse J.; Rademeyer, P.
2011-03-01
Display technologies always seem to find a wide range of interesting applications. As devices develop towards miniaturization, niche applications for small displays may emerge. While OLEDs and LCDs dominate the market for small displays, they have some shortcomings as relatively expensive technologies. Although CMOS is certainly not the dominating semiconductor for photonics, its widespread use, favourable cost and robustness present an attractive potential if it could find application in the microdisplay environment. Advances in improving the quantum efficiency of avalanche electroluminescence and the favourable spectral characteristics of light generated through the said mechanism may afford CMOS the possibility to be used as a display technology. This work shows that it is possible to integrate a fully functional display in a completely standard CMOS technology mainly geared towards digital design while using light sources completely compatible with the process and without any post processing required.
NASA Technical Reports Server (NTRS)
Lala, J. H.; Smith, T. B., III
1983-01-01
The software developed for the Fault-Tolerant Multiprocessor (FTMP) is described. The FTMP executive is a timer-interrupt driven dispatcher that schedules iterative tasks which run at 3.125, 12.5, and 25 Hz. Major tasks which run under the executive include system configuration control, flight control, and display. The flight control task includes autopilot and autoland functions for a jet transport aircraft. System Displays include status displays of all hardware elements (processors, memories, I/O ports, buses), failure log displays showing transient and hard faults, and an autopilot display. All software is in a higher order language (AED, an ALGOL derivative). The executive is a fully distributed general purpose executive which automatically balances the load among available processor triads. Provisions for graceful performance degradation under processing overload are an integral part of the scheduling algorithms.
Mazerolles, Fabienne; Stolzenberg, Marie-Claude; Pelle, Olivier; Picard, Capucine; Neven, Benedicte; Fischer, Alain; Magerus-Chatinet, Aude; Rieux-Laucat, Frederic
2018-01-01
Autoimmune lymphoproliferative syndrome (ALPS) with FAS mutation (ALPS-FAS) is a nonmalignant, noninfectious, lymphoproliferative disease with autoimmunity. Given the central role of natural regulatory T cells (nTregs) in the control of lymphoproliferation and autoimmunity, we assessed nTreg-suppressive function in 16 patients with ALPS-FAS. The proportion of CD25 high CD127 low Tregs was lower in ALPS-FAS patients than in healthy controls. This subset was correlated with a reduced CD25 expression in CD3 + CD4 + T cells from ALPS patients and thus an abnormally low proportion of CD25 high FOXP3 + Helios + T cells. The ALPS patients also displayed a high proportion of naïve Treg (FOXP3 low CD45RA + ) and an unusual subpopulation (CD4 + CD127 low CD15s + CD45RA + ). Despite this abnormal phenotype, the CD25 high CD127 low Tregs' suppressive function was unaffected. Furthermore, conventional T cells from FAS -mutated patients showed normal levels of sensitivity to Treg suppression. An abnormal Treg phenotype is observed in circulating lymphocytes of ALPS patients. However, these Tregs displayed a normal suppressive function on T effector proliferation in vitro . This is suggesting that lymphoproliferation observed in ALPS patients does not result from Tregs functional defect or T effector cells insensitivity to Tregs suppression.
NASA Technical Reports Server (NTRS)
Dey, D.
1972-01-01
The effect of a prediction display on the human transfer characteristics is explained with the aid of a quasi-linear model. The prediction display causes an increase of the gain factor and the lead factor, a diminishing of the lag factor and a decrease of the remnant. Altogether, these factors yield a smaller mean square value of the control deviation and a simultaneous decrease of the mean square value of the stick signal.
Lens ray diagrams with a spreadsheet
NASA Astrophysics Data System (ADS)
González, Manuel I.
2018-05-01
Physicists create spreadsheets customarily to carry out numerical calculations and to display their results in a meaningful, nice-looking way. Spreadsheets can also be used to display a vivid geometrical model of a physical system. This statement is illustrated with an example taken from geometrical optics: images formed by a thin lens. A careful mixture of standard Excel functions allows to display a realistic automated ray diagram. The suggested spreadsheet is intended as an auxiliary didactic tool for instructors who wish to teach their students to create their own ray diagrams.
Advanced Transport Operating System (ATOPS) control display unit software description
NASA Technical Reports Server (NTRS)
Slominski, Christopher J.; Parks, Mark A.; Debure, Kelly R.; Heaphy, William J.
1992-01-01
The software created for the Control Display Units (CDUs), used for the Advanced Transport Operating Systems (ATOPS) project, on the Transport Systems Research Vehicle (TSRV) is described. Module descriptions are presented in a standardized format which contains module purpose, calling sequence, a detailed description, and global references. The global reference section includes subroutines, functions, and common variables referenced by a particular module. The CDUs, one for the pilot and one for the copilot, are used for flight management purposes. Operations performed with the CDU affects the aircraft's guidance, navigation, and display software.
Pershad, Kritika; Wypisniak, Karolina; Kay, Brian K.
2012-01-01
While affinity reagents are valuable tools for monitoring protein phosphorylation and studying signaling events in cells, generating them through immunization of animals with phosphopeptides is expensive, laborious and time consuming. An attractive alternative is to use protein evolution techniques and isolate new anti-phosphopeptide binding specificities from a library of variants of a phosphopeptide-binding domain. To explore this strategy, we attempted to display on the surface of bacteriophage M13, the N-terminal Forkhead-associated domain (FHA1) of yeast Rad53p, which is a naturally occurring phosphothreonine (pT)-binding domain, and found it to be non-functional due to misfolding in the bacterial periplasm. To overcome this limitation, a library of FHA1 variants was constructed by mutagenic PCR and functional variants were isolated after three rounds of affinity selection with its pT peptide ligand. A hydrophobic residue at position 34 in the β1-strand was discovered to be essential for phage-display of a functional FHA1 domain. Additionally, by heating the phage library to 50°C prior to affinity selection with its cognate pT peptide, we identified a variant (G2) that was ~8°C more thermal stable than the wild-type domain. Using G2 as a scaffold, we constructed phage-displayed libraries of FHA1 variants and affinity selected for variants that bound selectively to five pT peptides. These reagents are renewable and have high protein yields (~20–25 mg/L), when expressed in Escherichia coli. Thus, we have changed the specificity of the FHA1 domain and demonstrated that engineering phosphopeptide-binding domains is an attractive avenue for generating new anti-phosphopeptide binding specificities in vitro by phage-display. PMID:22985966
Kim, Young Eun; Kim, Yu-na; Kim, Jung A.; Kim, Ho Min; Jung, Yongwon
2015-01-01
Supramolecular protein assemblies offer novel nanoscale architectures with molecular precision and unparalleled functional diversity. A key challenge, however, is to create precise nano-assemblies of functional proteins with both defined structures and a controlled number of protein-building blocks. Here we report a series of supramolecular green fluorescent protein oligomers that are assembled in precise polygonal geometries and prepared in a monodisperse population. Green fluorescent protein is engineered to be self-assembled in cells into oligomeric assemblies that are natively separated in a single-protein resolution by surface charge manipulation, affording monodisperse protein (nano)polygons from dimer to decamer. Several functional proteins are multivalently displayed on the oligomers with controlled orientations. Spatial arrangements of protein oligomers and displayed functional proteins are directly visualized by a transmission electron microscope. By employing our functional protein assemblies, we provide experimental insight into multivalent protein–protein interactions and tools to manipulate receptor clustering on live cell surfaces. PMID:25972078
Penny, Daniel J; Krishnamurthy, Rajesh
2016-08-01
The objectives of this review are to discuss the pathophysiology of the circulation with a functionally univentricular heart, with a focus on the unique physiologic characteristics, which provide the underpinnings for the management of these complex patients. MEDLINE and PubMed. The circulation of the patient with a functionally univentricular heart displays unique physiologic characteristics, which are quite different from those of the normal biventricular circulation. There are profound differences within the heart itself in terms of ventricular function, interventricular interactions, and myocardial architecture, which are likely to have significant implications for the efficiency of ventricular ejection and metabolism. The coupling between the systemic ventricle and the aorta also displays unique features. The 3D orientation of the Fontan anastomosis itself can profoundly impact cardiac output, although the "portal" pulmonary arterial bed is a crucial determinant of overall cardiovascular function. As a result, disease-specific approaches to improve cardiovascular function are required at all stages during the care of these complex patients.
Monocular display unit for 3D display with correct depth perception
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Hosomi, Takashi
2009-11-01
A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.
Code of Federal Regulations, 2011 CFR
2011-04-01
... OF CLASS II GAMES § 547.9 What are the minimum technical standards for Class II gaming system... digits to accommodate the design of the game. (3) Accounting data displayed to the player may be... audit, configuration, recall and test modes; or (ii) Temporarily, during entertaining displays of game...
Code of Federal Regulations, 2010 CFR
2010-04-01
... OF CLASS II GAMES § 547.9 What are the minimum technical standards for Class II gaming system... digits to accommodate the design of the game. (3) Accounting data displayed to the player may be... audit, configuration, recall and test modes; or (ii) Temporarily, during entertaining displays of game...
Code of Federal Regulations, 2012 CFR
2012-04-01
... OF CLASS II GAMES § 547.9 What are the minimum technical standards for Class II gaming system... digits to accommodate the design of the game. (3) Accounting data displayed to the player may be... audit, configuration, recall and test modes; or (ii) Temporarily, during entertaining displays of game...
Restoration of moving binary images degraded owing to phosphor persistence.
Cherri, A K; Awwal, A A; Karim, M A; Moon, D L
1991-09-10
The degraded images of dynamic objects obtained by using a phosphor-based electro-optical display are analyzed in terms of dynamic modulation transfer function (DMTF) and temporal characteristics of the display system. The direct correspondence between the DMTF and image smear is used in developing real-time techniques for the restoration of degraded images.
Item Analysis and Differential Item Functioning of a Brief Conduct Problem Screen
ERIC Educational Resources Information Center
Wu, Johnny; King, Kevin M.; Witkiewitz, Katie; Racz, Sarah Jensen; McMahon, Robert J.
2012-01-01
Research has shown that boys display higher levels of childhood conduct problems than girls, and Black children display higher levels than White children, but few studies have tested for scalar equivalence of conduct problems across gender and race. The authors conducted a 2-parameter item response theory (IRT) model to examine item…
1992-01-01
cognitive function. For example. physiological methods allow for visual sensitivity measurements in infants and children with about the same level of...potential (ERP), the event-related magnetic field (ERF), and pupillometry . Where possible, we cite specific experiments that deal with display or stimulus...technical barrier preventing the application of these methods to the analysis of human performance with color displays. Pupillometry . The pupillary
Asymptote Misconception on Graphing Functions: Does Graphing Software Resolve It?
ERIC Educational Resources Information Center
Öçal, Mehmet Fatih
2017-01-01
Graphing function is an important issue in mathematics education due to its use in various areas of mathematics and its potential roles for students to enhance learning mathematics. The use of some graphing software assists students' learning during graphing functions. However, the display of graphs of functions that students sketched by hand may…
NASA Technical Reports Server (NTRS)
1979-01-01
The functions performed by the systems management (SM) application software are described along with the design employed to accomplish these functions. The operational sequences (OPS) control segments and the cyclic processes they control are defined. The SM specialist function control (SPEC) segments and the display controlled 'on-demand' processes that are invoked by either an OPS or SPEC control segment as a direct result of an item entry to a display are included. Each processing element in the SM application is described including an input/output table and a structured control flow diagram. The flow through the module and other information pertinent to that process and its interfaces to other processes are included.
Demonstration Advanced Avionics System (DAAS) function description
NASA Technical Reports Server (NTRS)
Bailey, A. J.; Bailey, D. G.; Gaabo, R. J.; Lahn, T. G.; Larson, J. C.; Peterson, E. M.; Schuck, J. W.; Rodgers, D. L.; Wroblewski, K. A.
1982-01-01
The Demonstration Advanced Avionics System, DAAS, is an integrated avionics system utilizing microprocessor technologies, data busing, and shared displays for demonstrating the potential of these technologies in improving the safety and utility of general aviation operations in the late 1980's and beyond. Major hardware elements of the DAAS include a functionally distributed microcomputer complex, an integrated data control center, an electronic horizontal situation indicator, and a radio adaptor unit. All processing and display resources are interconnected by an IEEE-488 bus in order to enhance the overall system effectiveness, reliability, modularity and maintainability. A detail description of the DAAS architecture, the DAAS hardware, and the DAAS functions is presented. The system is designed for installation and flight test in a NASA Cessna 402-B aircraft.
Functionalized carbon nanotubes for potential medicinal applications.
Zhang, Yi; Bai, Yuhong; Yan, Bing
2010-06-01
Functionalized carbon nanotubes display unique properties that enable a variety of medicinal applications, including the diagnosis and treatment of cancer, infectious diseases and central nervous system disorders, and applications in tissue engineering. These potential applications are particularly encouraged by their ability to penetrate biological membranes and relatively low toxicity. High aspect ratio, unique optical property and the likeness as small molecule make carbon nanotubes an unusual allotrope of element carbon. After functionalization, carbon nanotubes display potentials for a variety of medicinal applications, including the diagnosis and treatment of cancer, infectious diseases and central nervous system disorders, and applications in tissue engineering. These potential applications are particularly encouraged by their ability to penetrate biological membranes and relatively low toxicity. (c) 2010 Elsevier Ltd. All rights reserved.
Rubinstein, M; Mogil, J S; Japón, M; Chan, E C; Allen, R G; Low, M J
1996-01-01
A physiological role for beta-endorphin in endogenous pain inhibition was investigated by targeted mutagenesis of the proopiomelanocortin gene in mouse embryonic stem cells. The tyrosine codon at position 179 of the proopiomelanocortin gene was converted to a premature translational stop codon. The resulting transgenic mice display no overt developmental or behavioral alterations and have a normally functioning hypothalamic-pituitary-adrenal axis. Homozygous transgenic mice with a selective deficiency of beta-endorphin exhibit normal analgesia in response to morphine, indicating the presence of functional mu-opiate receptors. However, these mice lack the opioid (naloxone reversible) analgesia induced by mild swim stress. Mutant mice also display significantly greater nonopioid analgesia in response to cold water swim stress compared with controls and display paradoxical naloxone-induced analgesia. These changes may reflect compensatory upregulation of alternative pain inhibitory mechanisms. Images Fig. 1 Fig. 2 PMID:8633004
IDIMS/GEOPAK: Users manual for a geophysical data display and analysis system
NASA Technical Reports Server (NTRS)
Libert, J. M.
1982-01-01
The application of an existing image analysis system to the display and analysis of geophysical data is described, the potential for expanding the capabilities of such a system toward more advanced computer analytic and modeling functions is investigated. The major features of the IDIMS (Interactive Display and Image Manipulation System) and its applicability for image type analysis of geophysical data are described. Development of a basic geophysical data processing system to permit the image representation, coloring, interdisplay and comparison of geophysical data sets using existing IDIMS functions and to provide for the production of hard copies of processed images was described. An instruction manual and documentation for the GEOPAK subsystem was produced. A training course for personnel in the use of the IDIMS/GEOPAK was conducted. The effectiveness of the current IDIMS/GEOPAK system for geophysical data analysis was evaluated.
[A solution for display and processing of DICOM images in web PACS].
Xue, Wei-jing; Lu, Wen; Wang, Hai-yang; Meng, Jian
2009-03-01
Use the technique of Java Applet to realize the supporting of DICOM image in ordinary Web browser, thereby to expand the processing function of medical image. First analyze the format of DICOM file and design a class which can acquire the pixels, then design two Applet classes, of which one is used to disposal the DICOM image, the other is used to display DICOM image that have been disposaled in the first Applet. They all embedded in the View page, and they communicate by Applet Context object. The method designed in this paper can make users display and process DICOM images directly by using ordinary Web browser, which makes Web PACS not only have the advantages of B/S model, but also have the advantages of the C/S model. Java Applet is the key for expanding the Web browser's function in Web PACS, which provides a guideline to sharing of medical images.
NASA Astrophysics Data System (ADS)
Beasley, Howard H.; Martin, John S.; Klymenko, Victor; Harding, Thomas H.; Verona, Robert W.; Rash, Clarence E.
1995-07-01
A counterphase modulation technique is used to measure the static and dynamic modulation transfer functions for three phosphorus of current interest to U.S. Army aviation helmet-mounted displays (P-1, P-43, and P-53). A family of modulation transfer curves, one for each temporal frequency, is presented for each phosphorus. The measured MFT curves generally support the supposition that phosphorus persistence is a critical parameter in the ability of a CRT display to accurately reproduce contrast modulation transfer in dynamic environments.
Frequency encoded auditory display of the critical tracking task
NASA Technical Reports Server (NTRS)
Stevenson, J.
1984-01-01
The use of auditory displays for selected cockpit instruments was examined. In auditory, visual, and combined auditory-visual compensatory displays of a vertical axis, critical tracking task were studied. The visual display encoded vertical error as the position of a dot on a 17.78 cm, center marked CRT. The auditory display encoded vertical error as log frequency with a six octave range; the center point at 1 kHz was marked by a 20-dB amplitude notch, one-third octave wide. Asymptotic performance on the critical tracking task was significantly better when using combined displays rather than the visual only mode. At asymptote, the combined display was slightly, but significantly, better than the visual only mode. The maximum controllable bandwidth using the auditory mode was only 60% of the maximum controllable bandwidth using the visual mode. Redundant cueing increased the rate of improvement of tracking performance, and the asymptotic performance level. This enhancement increases with the amount of redundant cueing used. This effect appears most prominent when the bandwidth of the forcing function is substantially less than the upper limit of controllability frequency.
Spatial noise in microdisplays for near-to-eye applications
NASA Astrophysics Data System (ADS)
Hastings, Arthur R., Jr.; Draper, Russell S.; Wood, Michael V.; Fellowes, David A.
2011-06-01
Spatial noise in imaging systems has been characterized and its impact on image quality metrics has been addressed primarily with respect to the introduction of this noise at the sensor component. However, sensor fixed pattern noise is not the only source of fixed pattern noise in an imaging system. Display fixed pattern noise cannot be easily mitigated in processing and, therefore, must be addressed. In this paper, a thorough examination of the amount and the effect of display fixed pattern noise is presented. The specific manifestation of display fixed pattern noise is dependent upon the display technology. Utilizing a calibrated camera, US Army RDECOM CERDEC NVESD has developed a microdisplay (μdisplay) spatial noise data collection capability. Noise and signal power spectra were used to characterize the display signal to noise ratio (SNR) as a function of spatial frequency analogous to the minimum resolvable temperature difference (MRTD) of a thermal sensor. The goal of this study is to establish a measurement technique to characterize μdisplay limiting performance to assist in proper imaging system specification.
NASA Technical Reports Server (NTRS)
Batson, Vernon M.; Robertson, James B.; Parrish, Russell V.
1990-01-01
The aircraft cockpit ambient lighting simulation system (ACALSS) has been developed to study display readability and associated pilot/vehicle performance effects in a part-task simulator cockpit. In the study reported here, the ACALSS was used to determine the illumination levels at which subjects lose the ability to maintain aircraft states when using three display technologies as display media for primary flight displays: a standard monochrome EL (electroluminescent) flat-panel, a laboratory-class monochrome CRT, and an enhanced-brightness EL flat-panel. The multivariate statistical technique of modified profile analysis was used to test for performance differences between display devices as functions of illumination levels. The standard monochrome EL flat-panel display began to washout after the 2500 foot-candle level of illumination. The monochrome CRT began to washout after the 5500 foot-candle level of illumination. No performance decrements by increased illumination up to the 12,000 foot-candle level were found for the enhanced-brightness EL flat-panel display. What was not anticipated was that half the subjects would subjectively prefer the CRT over the enhanced-brightness EL, even though their performance errors would have indicated the opposite.
Advance in phage display technology for bioanalysis.
Tan, Yuyu; Tian, Tian; Liu, Wenli; Zhu, Zhi; J Yang, Chaoyong
2016-06-01
Phage display technology has emerged as a powerful tool for target gene expression and target-specific ligand selection. It is widely used to screen peptides, proteins and antibodies with the advantages of simplicity, high efficiency and low cost. A variety of targets, including ions, small molecules, inorganic materials, natural and biological polymers, nanostructures, cells, bacteria, and even tissues, have been demonstrated to generate specific binding ligands by phage display. Phages and target-specific ligands screened by phage display have been widely used as affinity reagents in therapeutics, diagnostics and biosensors. In this review, comparisons of different types of phage display systems are first presented. Particularly, microfluidic-based phage display, which enables screening with high throughput, high efficiency and integration, is highlighted. More importantly, we emphasize the advances in biosensors based on phages or phage-derived probes, including nonlytic phages, lytic phages, peptides or proteins screened by phage display, phage assemblies and phage-nanomaterial complexes. However, more efficient and higher throughput phage display methods are still needed to meet an explosion in demand for bioanalysis. Furthermore, screening of cyclic peptides and functional peptides will be the hotspot in bioanalysis. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lizard threat display handicaps endurance.
Brandt, Y
2003-01-01
Honest-signalling theory asserts that threat displays reliably advertise attributes that influence fighting success. Endurance, as measured by treadmill performance, predicts the outcome of agonistic interactions among lizards. If threat displays in lizards function to advertise endurance capacity then variation in threat displays should correlate with endurance. I tested this prediction for the duration of threat posturing in male side-blotched lizards (Uta stansburiana) and examined whether threat displays act as quality handicaps, reliable signals that expend the attribute that is advertised. Individual variation in the duration of threat posturing correlated with endurance, while an experimental reduction of endurance diminished the duration of threat posturing. As expected of a quality handicap, endurance fell below baseline after display production. A restriction of aerobic metabolism can account for this effect. In threat posturing, lateral compression of the thorax may interfere with respiration or with circulation, limiting aerobic metabolism and causing a compensatory increase in anaerobic metabolism, thereby generating lactate and diminishing locomotor capacity. Concentrations of lactate measured after display production were higher than baseline, consistent with the proposed mechanism. By restricting aerobic metabolism, the threat posture can act as a quality handicap, simultaneously advertising and expending the endurance capacity of displaying lizards. PMID:12803896
Evaluation of viewing experiences induced by a curved three-dimensional display
NASA Astrophysics Data System (ADS)
Mun, Sungchul; Park, Min-Chul; Yano, Sumio
2015-10-01
Despite an increased need for three-dimensional (3-D) functionality in curved displays, comparisons pertinent to human factors between curved and flat panel 3-D displays have rarely been tested. This study compared stereoscopic 3-D viewing experiences induced by a curved display with those of a flat panel display by evaluating subjective and objective measures. Twenty-four participants took part in the experiments and viewed 3-D content with two different displays (flat and curved 3-D display) within a counterbalanced and within-subject design. For the 30-min viewing condition, a paired t-test showed significantly reduced P300 amplitudes, which were caused by engagement rather than cognitive fatigue, in the curved 3-D viewing condition compared to the flat 3-D viewing condition at P3 and P4. No significant differences in P300 amplitudes were observed for 60-min viewing. Subjective ratings of realness and engagement were also significantly higher in the curved 3-D viewing condition than in the flat 3-D viewing condition for 30-min viewing. Our findings support that curved 3-D displays can be effective for enhancing engagement among viewers based on specific viewing times and environments.
Polyplanar optical display electronics
NASA Astrophysics Data System (ADS)
DeSanto, Leonard; Biscardi, Cyrus
1997-07-01
The polyplanar optical display (POD) is a unique display screen which can be used with any projection source. The prototype ten inch display is two inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. In order to achieve a long lifetime, the new display uses a 100 milliwatt green solid- state laser at 532 nm as its light source. To produce real- time video, the laser light is being modulated by a digital light processing (DLP) chip manufactured by Texas Instruments. In order to use the solid-state laser as the light source and also fit within the constraints of the B-52 display, the digital micromirror device (DMD) circuit board is removed from the Texas Instruments DLP light engine assembly. Due to the compact architecture of the projection system within the display chassis, the DMD chip is operated remotely from the Texas Instruments circuit board. We discuss the operation of the DMD divorced from the light engine and the interfacing of the DMD board with various video formats including the format specific to the B-52 aircraft. A brief discussion of the electronics required to drive the laser is also presented.
Heading control and the effects of display characteristics
NASA Technical Reports Server (NTRS)
Hinz, Stephanie J.; Bennett, C. Thomas
1989-01-01
The present study evaluates whether type of display (dot or wire frame) and direction of movement have an effect on a person's ability to actively maintain a specific heading angle. The questions addressed were: (1) does the magnitude of the heading angle errors differ in the two displays, (2) are some heading angles more difficult to maintain than others, and (3) does the magnitude of some errors differ as a function of display type and direction of movement. Differences between the results of this study and previous research are explained by methodological differences across the studies. Another factor that may be responsible for the difference between previous findings and those presented here is the type of graphics used to display the simulated motion. The physical characteristics of the display or the graphics engines that generate the scene have varied greatly across the studies. Analyses and diagrams are presented showing results of the study and the differences generated from previous studies on this subject.
Simultaneous display of two large proteins on the head and tail of bacteriophage lambda
2013-01-01
Background Consistent progress in the development of bacteriophage lambda display platform as an alternative to filamentous phage display system was achieved in the recent years. The lambda phage has been engineered to display efficiently multiple copies of peptides or even large protein domains providing a powerful tool for screening libraries of peptides, proteins and cDNA. Results In the present work we describe an original method for dual display of large proteins on the surface of lambda particles. An anti-CEA single-chain antibody fragment and green fluorescent protein or alkaline phosphatase were simultaneously displayed by engineering both gpD and gpV lambda proteins. Conclusions Here we show that such modified phage particles can be used for the detection of target molecules in vitro and in vivo. Dual expression of functional moieties on the surface of the lambda phage might open the way to generation of a new class of diagnostic and therapeutic targeted nanoparticles. PMID:24073829
NASA Technical Reports Server (NTRS)
Clement, W. F.
1976-01-01
The use which pilots make of a moving map display from en route through the terminal area and including the approach and go-around flight phases was investigated. The content and function of each of three primary STOLAND displays are reviewed from an operational point of view. The primary displays are the electronic attitude director indicator (EADI), the horizontal situation indicator (HSI), and the multifunction display (MFD). Manually controlled flight with both flight director guidance and raw situation data is examined in detail in a simulated flight experiment with emphasis on tracking reference flight plans and maintaining geographic orientation after missed approaches. Eye-point-of-regard and workload measurements, coupled with task performance measurements, pilot opinion ratings, and pilot comments are presented. The experimental program was designed to offer a systematic objective and subjective comparison of pilots' use of the moving map MFD in conjunction with the other displays.
Evaluation of viewing experiences induced by curved 3D display
NASA Astrophysics Data System (ADS)
Mun, Sungchul; Park, Min-Chul; Yano, Sumio
2015-05-01
As advanced display technology has been developed, much attention has been given to flexible panels. On top of that, with the momentum of the 3D era, stereoscopic 3D technique has been combined with the curved displays. However, despite the increased needs for 3D function in the curved displays, comparisons between curved and flat panel displays with 3D views have rarely been tested. Most of the previous studies have investigated their basic ergonomic aspects such as viewing posture and distance with only 2D views. It has generally been known that curved displays are more effective in enhancing involvement in specific content stories because field of views and distance from the eyes of viewers to both edges of the screen are more natural in curved displays than in flat panel ones. For flat panel displays, ocular torsions may occur when viewers try to move their eyes from the center to the edges of the screen to continuously capture rapidly moving 3D objects. This is due in part to differences in viewing distances from the center of the screen to eyes of viewers and from the edges of the screen to the eyes. Thus, this study compared S3D viewing experiences induced by a curved display with those of a flat panel display by evaluating significant subjective and objective measures.
Three-dimensional (3D) GIS-based coastline change analysis and display using LIDAR series data
NASA Astrophysics Data System (ADS)
Zhou, G.
This paper presents a method to visualize and analyze topography and topographic changes on coastline area. The study area, Assantage Island Nation Seashore (AINS), is located along a 37-mile stretch of Assateague Island National Seashore in Eastern Shore, VA. The DEMS data sets from 1996 through 2000 for various time intervals, e.g., year-to-year, season-to-season, date-to-date, and a four year (1996-2000) are created. The spatial patterns and volumetric amounts of erosion and deposition of each part on a cell-by-cell basis were calculated. A 3D dynamic display system using ArcView Avenue for visualizing dynamic coastal landforms has been developed. The system was developed into five functional modules: Dynamic Display, Analysis, Chart analysis, Output, and Help. The Display module includes five types of displays: Shoreline display, Shore Topographic Profile, Shore Erosion Display, Surface TIN Display, and 3D Scene Display. Visualized data include rectified and co-registered multispectral Landsat digital image and NOAA/NASA ATM LIDAR data. The system is demonstrated using multitemporal digital satellite and LIDAR data for displaying changes on the Assateague Island National Seashore, Virginia. The analyzed results demonstrated that a further understanding to the study and comparison of the complex morphological changes that occur naturally or human-induced on barrier islands is required.
Kesner, Raymond P; Kirk, Ryan A; Yu, Zhenghui; Polansky, Caitlin; Musso, Nick D
2016-03-01
In order to examine the role of the dorsal dentate gyrus (dDG) in slope (vertical space) recognition and possible pattern separation, various slope (vertical space) degrees were used in a novel exploratory paradigm to measure novelty detection for changes in slope (vertical space) recognition memory and slope memory pattern separation in Experiment 1. The results of the experiment indicate that control rats displayed a slope recognition memory function with a pattern separation process for slope memory that is dependent upon the magnitude of change in slope between study and test phases. In contrast, the dDG lesioned rats displayed an impairment in slope recognition memory, though because there was no significant interaction between the two groups and slope memory, a reliable pattern separation impairment for slope could not be firmly established in the DG lesioned rats. In Experiment 2, in order to determine whether, the dDG plays a role in shades of grey spatial context recognition and possible pattern separation, shades of grey were used in a novel exploratory paradigm to measure novelty detection for changes in the shades of grey context environment. The results of the experiment indicate that control rats displayed a shades of grey-context pattern separation effect across levels of separation of context (shades of grey). In contrast, the DG lesioned rats displayed a significant interaction between the two groups and levels of shades of grey suggesting impairment in a pattern separation function for levels of shades of grey. In Experiment 3 in order to determine whether the dorsal CA3 (dCA3) plays a role in object pattern completion, a new task requiring less training and using a choice that was based on choosing the correct set of objects on a two-choice discrimination task was used. The results indicated that control rats displayed a pattern completion function based on the availability of one, two, three or four cues. In contrast, the dCA3 lesioned rats displayed a significant interaction between the two groups and the number of available objects suggesting impairment in a pattern completion function for object cues. Copyright © 2015 Elsevier Inc. All rights reserved.
Digital Image Processing Overview For Helmet Mounted Displays
NASA Astrophysics Data System (ADS)
Parise, Michael J.
1989-09-01
Digital image processing provides a means to manipulate an image and presents a user with a variety of display formats that are not available in the analog image processing environment. When performed in real time and presented on a Helmet Mounted Display, system capability and flexibility are greatly enhanced. The information content of a display can be increased by the addition of real time insets and static windows from secondary sensor sources, near real time 3-D imaging from a single sensor can be achieved, graphical information can be added, and enhancement techniques can be employed. Such increased functionality is generating a considerable amount of interest in the military and commercial markets. This paper discusses some of these image processing techniques and their applications.
New displays and new emotions: a commentary on Rozin and Cohen (2003).
Keltner, Dacher; Shiota, Michelle N
2003-03-01
In this article, the authors elaborate on 3 ideas advanced in P. Rozin and A. B. Cohen's (2003) innovative study of facial expression. Taking a cue from their discovery of new expressive behaviors (e.g., the narrowed eyebrows), the authors review recent studies showing that emotions are conveyed in more channels than usually studied, including posture, gaze patterns, voice, and touch. Building on their claim that confusion has a distinct display, the authors review evidence showing distinct displays for 3 self-conscious emotions (embarrassment, shame, and pride), 5 positive emotions (amusement, desire, happiness, love, interest), and sympathy and compassion. Finally, the authors offer a functional definition of emotion to integrate these findings on "new" displays and emotions.
Phage display—A powerful technique for immunotherapy
Bazan, Justyna; Całkosiński, Ireneusz; Gamian, Andrzej
2012-01-01
One of the most effective molecular diversity techniques is phage display. This technology is based on a direct linkage between phage phenotype and its encapsulated genotype, which leads to presentation of molecule libraries on the phage surface. Phage display is utilized in studying protein-ligand interactions, receptor binding sites and in improving or modifying the affinity of proteins for their binding partners. Generating monoclonal antibodies and improving their affinity, cloning antibodies from unstable hybridoma cells and identifying epitopes, mimotopes and functional or accessible sites from antigens are also important advantages of this technology. Techniques originating from phage display have been applied to transfusion medicine, neurological disorders, mapping vascular addresses and tissue homing of peptides. Phages have been applicable to immunization therapies, which may lead to development of new tools used for treating autoimmune and cancer diseases. This review describes the phage display technology and presents the recent advancements in therapeutic applications of phage display. PMID:22906939
Inexpensive Monocular Pico-Projector-based Augmented Reality Display for Surgical Microscope
Shi, Chen; Becker, Brian C.; Riviere, Cameron N.
2013-01-01
This paper describes an inexpensive pico-projector-based augmented reality (AR) display for a surgical microscope. The system is designed for use with Micron, an active handheld surgical tool that cancels hand tremor of surgeons to improve microsurgical accuracy. Using the AR display, virtual cues can be injected into the microscope view to track the movement of the tip of Micron, show the desired position, and indicate the position error. Cues can be used to maintain high performance by helping the surgeon to avoid drifting out of the workspace of the instrument. Also, boundary information such as the view range of the cameras that record surgical procedures can be displayed to tell surgeons the operation area. Furthermore, numerical, textual, or graphical information can be displayed, showing such things as tool tip depth in the work space and on/off status of the canceling function of Micron. PMID:25264542
Call sign intelligibility improvement using a spatial auditory display
NASA Technical Reports Server (NTRS)
Begault, Durand R.
1994-01-01
A spatial auditory display was designed for separating the multiple communication channels usually heard over one ear to different virtual auditory positions. The single 19 foot rack mount device utilizes digital filtering algorithms to separate up to four communication channels. The filters use four different binaural transfer functions, synthesized from actual outer ear measurements, to impose localization cues on the incoming sound. Hardware design features include 'fail-safe' operation in the case of power loss, and microphone/headset interfaces to the mobile launch communication system in use at KSC. An experiment designed to verify the intelligibility advantage of the display used 130 different call signs taken from the communications protocol used at NASA KSC. A 6 to 7 dB intelligibility advantage was found when multiple channels were spatially displayed, compared to monaural listening. The findings suggest that the use of a spatial auditory display could enhance both occupational and operational safety and efficiency of NASA operations.
Fluorescent protein integrated white LEDs for displays
NASA Astrophysics Data System (ADS)
Press, Daniel Aaron; Melikov, Rustamzhon; Conkar, Deniz; Nur Firat-Karalar, Elif; Nizamoglu, Sedat
2016-11-01
The usage time of displays (e.g., TVs, mobile phones, etc) is in general shorter than their functional life time, which worsens the electronic waste (e-waste) problem around the world. The integration of biomaterials into electronics can help to reduce the e-waste problem. In this study, we demonstrate fluorescent protein integrated white LEDs to use as a backlight source for liquid crystal (LC) displays for the first time. We express and purify enhanced green fluorescent protein (eGFP) and monomeric Cherry protein (mCherry), and afterward we integrate these proteins as a wavelength-converter on a blue LED chip. The protein-integrated backlight exhibits a high luminous efficacy of 248 lm/Wopt and the area of the gamut covers 80% of the NTSC color gamut. The resultant colors and objects in the image on the display can be well observed and distinguished. Therefore, fluorescent proteins show promise for display applications.
Object-based warping: an illusory distortion of space within objects.
Vickery, Timothy J; Chun, Marvin M
2010-12-01
Visual objects are high-level primitives that are fundamental to numerous perceptual functions, such as guidance of attention. We report that objects warp visual perception of space in such a way that spatial distances within objects appear to be larger than spatial distances in ground regions. When two dots were placed inside a rectangular object, they appeared farther apart from one another than two dots with identical spacing outside of the object. To investigate whether this effect was object based, we measured the distortion while manipulating the structure surrounding the dots. Object displays were constructed with a single object, multiple objects, a partially occluded object, and an illusory object. Nonobject displays were constructed to be comparable to object displays in low-level visual attributes. In all cases, the object displays resulted in a more powerful distortion of spatial perception than comparable non-object-based displays. These results suggest that perception of space within objects is warped.
Colorful displays signal male quality in a tropical anole lizard
NASA Astrophysics Data System (ADS)
Cook, Ellee G.; Murphy, Troy G.; Johnson, Michele A.
2013-10-01
Parasites influence colorful ornaments and their behavioral display in many animal hosts. Because coloration and display behavior are often critical components of communication, variation in these traits may have important implications for individual fitness, yet it remains unclear whether such traits are signals of quality in many taxa. We investigated the association between ectoparasitic mite load and the color and behavioral use of the throat fan (dewlap) by male Anolis brevirostris lizards. We found that heavily parasitized lizards exhibited lower body condition, duller dewlaps, and less frequent dewlap displays than less parasitized individuals. Our results thus suggest that highly parasitized individuals invest less in both ornamental color and behavioral display of that color. Because the two components of the signal simultaneously provide information on male quality, this study provides novel support for the long-standing hypothesis that colorful traits may function as social or sexual signals in reptiles.
Cheng, Ning-Hui; Pittman, Jon K.; Shigaki, Toshiro; Lachmansingh, Jinesh; LeClere, Sherry; Lahner, Brett; Salt, David E.; Hirschi, Kendal D.
2005-01-01
Cation levels within the cytosol are coordinated by a network of transporters. Here, we examine the functional roles of calcium exchanger 1 (CAX1), a vacuolar H+/Ca2+ transporter, and the closely related transporter CAX3. We demonstrate that like CAX1, CAX3 is also localized to the tonoplast. We show that CAX1 is predominately expressed in leaves, while CAX3 is highly expressed in roots. Previously, using a yeast assay, we demonstrated that an N-terminal truncation of CAX1 functions as an H+/Ca2+ transporter. Here, we use the same yeast assay to show that full-length CAX1 and full-length CAX3 can partially, but not fully, suppress the Ca2+ hypersensitive yeast phenotype and coexpression of full-length CAX1 and CAX3 conferred phenotypes not produced when either transporter was expressed individually. In planta, CAX3 null alleles were modestly sensitive to exogenous Ca2+ and also displayed a 22% reduction in vacuolar H+-ATPase activity. cax1/cax3 double mutants displayed a severe reduction in growth, including leaf tip and flower necrosis and pronounced sensitivity to exogenous Ca2+ and other ions. These growth defects were partially suppressed by addition of exogenous Mg2+. The double mutant displayed a 42% decrease in vacuolar H+/Ca2+ transport, and a 47% decrease in H+-ATPase activity. While the ionome of cax1 and cax3 lines were modestly perturbed, the cax1/cax3 lines displayed increased PO43−, Mn2+, and Zn2+ and decreased Ca2+ and Mg2+ in shoot tissue. These findings suggest synergistic function of CAX1 and CAX3 in plant growth and nutrient acquisition. PMID:16055687
Optimizing electricity consumption: A case of function learning.
Guath, Mona; Millroth, Philip; Juslin, Peter; Elwin, Ebba
2015-12-01
A popular way to improve consumers' control over their electricity consumption is by providing outcome feedback on the cost with in-home displays. Research on function learning, however, suggests that outcome feedback may not always be ideal for learning, especially if the feedback signal is noisy. In this study, we relate research on function learning to in-home displays and use a laboratory task simulating a household to investigate the role of outcome feedback and function learning on electricity optimization. Three function training schemes (FTSs) are presented that convey specific properties of the functions that relate the electricity consumption to the utility and cost. In Experiment 1, we compared learning from outcome feedback with 3 FTSs, 1 of which allowed maximization of the utility while keeping the budget, despite no feedback about the total monthly cost. In Experiment 2, we explored the combination of this FTS and outcome feedback. The results suggested that electricity optimization may be facilitated if feedback learning is preceded by a brief period of function training. (c) 2015 APA, all rights reserved).
Markovian Anderson Model: Bounds for the Rate of Propagation
NASA Astrophysics Data System (ADS)
Tcheremchantsev, Serguei
We consider the Anderson model in with potentials whose values at any site of the lattice are Markovian independent random functions of time. For solutions to the time-dependent Schrödinger equation we show under some conditions that with probability 1
Chris J. Cieszewski; Roger C. Lowe; Shangbin Liu; Ingvar Elle; Daniel Markewitz
2009-01-01
This article describes updates on the development of various applications for the Hypermaps applications and the newest versions of the forest inventory data display tool, Interactive Fast Online Reports and Maps (InFORM). The development of InFORM applications is cosponsored by the University of Georgia, Warnell School of Forestry and Natural Resources; the Forest...
49 CFR 236.526 - Roadway element not functioning properly.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Roadway element not functioning properly. 236.526... element not functioning properly. When a roadway element except track circuit of automatic train stop... roadway element shall be caused manually to display its most restrictive aspect until such element has...
49 CFR 236.526 - Roadway element not functioning properly.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Roadway element not functioning properly. 236.526... element not functioning properly. When a roadway element except track circuit of automatic train stop... roadway element shall be caused manually to display its most restrictive aspect until such element has...
49 CFR 236.526 - Roadway element not functioning properly.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Roadway element not functioning properly. 236.526... element not functioning properly. When a roadway element except track circuit of automatic train stop... roadway element shall be caused manually to display its most restrictive aspect until such element has...
43 CFR 423.22 - Interference with agency functions and disorderly conduct.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Interference with agency functions and..., AND WATERBODIES Rules of Conduct § 423.22 Interference with agency functions and disorderly conduct... behavior; (2) Language, utterance, gesture, display, or act that is obscene, physically threatening or...
Arming Technology in Yeast-Novel Strategy for Whole-cell Biocatalyst and Protein Engineering.
Kuroda, Kouichi; Ueda, Mitsuyoshi
2013-09-09
Cell surface display of proteins/peptides, in contrast to the conventional intracellular expression, has many attractive features. This arming technology is especially effective when yeasts are used as a host, because eukaryotic modifications that are often required for functional use can be added to the surface-displayed proteins/peptides. A part of various cell wall or plasma membrane proteins can be genetically fused to the proteins/peptides of interest to be displayed. This technology, leading to the generation of so-called "arming technology", can be employed for basic and applied research purposes. In this article, we describe various strategies for the construction of arming yeasts, and outline the diverse applications of this technology to industrial processes such as biofuel and chemical productions, pollutant removal, and health-related processes, including oral vaccines. In addition, arming technology is suitable for protein engineering and directed evolution through high-throughput screening that is made possible by the feature that proteins/peptides displayed on cell surface can be directly analyzed using intact cells without concentration and purification. Actually, novel proteins/peptides with improved or developed functions have been created, and development of diagnostic/therapeutic antibodies are likely to benefit from this powerful approach.
Practical social assessments for national forest planning.
Pamela Jakes; Thomas Fish; Deborah Carr; Dale Blahna
1998-01-01
Residents of northern Wisconsin identified functional communities--geographic areas in which people share perceptions of and relationships to forests and natural resources. Functional communities are a useful concept for displaying social information for forest management and planning.
Programmable biofilm-based materials from engineered curli nanofibres.
Nguyen, Peter Q; Botyanszki, Zsofia; Tay, Pei Kun R; Joshi, Neel S
2014-09-17
The significant role of biofilms in pathogenicity has spurred research into preventing their formation and promoting their disruption, resulting in overlooked opportunities to develop biofilms as a synthetic biological platform for self-assembling functional materials. Here we present Biofilm-Integrated Nanofiber Display (BIND) as a strategy for the molecular programming of the bacterial extracellular matrix material by genetically appending peptide domains to the amyloid protein CsgA, the dominant proteinaceous component in Escherichia coli biofilms. These engineered CsgA fusion proteins are successfully secreted and extracellularly self-assemble into amyloid nanofibre networks that retain the functions of the displayed peptide domains. We show the use of BIND to confer diverse artificial functions to the biofilm matrix, such as nanoparticle biotemplating, substrate adhesion, covalent immobilization of proteins or a combination thereof. BIND is a versatile nanobiotechnological platform for developing robust materials with programmable functions, demonstrating the potential of utilizing biofilms as large-scale designable biomaterials.
A New Wrist Clinical Evaluation Score.
Herzberg, Guillaume; Burnier, Marion; Nakamura, Toshiyasu
2018-04-01
Background The number of available wrist scoring systems is limited; some of them do not include forearm rotation criteria. Purpose To describe a new electronic wrist clinical score and to present a new patient's generated wrist evaluation criterion, the subjective wrist value (SWV). Materials and Methods A new electronic wrist clinical score, the Lyon wrist score (LWS) including wrist VAS pain and function, active range of motion and strength was built into an excel file. VAS flexion-extension pain and function were evaluated independently from pronation-supination pain and function. A new patient's generated wrist evaluation criterion, SWV was described. Results The LWS is available in two versions, standard and full (the latter including forearm rotation strength). Both standard and full LWS are displayed into an automatically generated diamond-shaped graph providing a comprehensive visual display of the clinical status of most osteoarticular wrist disorders. The graph also includes SWV. The LWS, combined with SWV into a graph that may be directly exported to a PowerPoint presentation, provide a new practical and comprehensive tool for following/comparing wrist osteoarticular clinical status/outcomes. Both standard and full LWS charts are available in colored versions on a related website for free download. Conclusion A comprehensive updated electronic display of osteoarticular wrist clinical status including forearm rotation criteria is provided and displayed into a graph which may be exported as such into a PowerPoint presentation for clinical analysis/comparisons. Level of Evidence Level II.
Dissecting binding of a β-barrel membrane protein by phage display.
Meneghini, Luz M; Tripathi, Sarvind; Woodworth, Marcus A; Majumdar, Sudipta; Poulos, Thomas L; Weiss, Gregory A
2017-07-25
Membrane proteins (MPs) constitute a third of all proteomes, and contribute to a myriad of cellular functions including intercellular communication, nutrient transport and energy generation. For example, TonB-dependent transporters (TBDTs) in the outer membrane of Gram-negative bacteria play an essential role transporting iron and other nutrients into the bacterial cell. The inherently hydrophobic surfaces of MPs complicates protein expression, purification, and characterization. Thus, dissecting the functional contributions of individual amino acids or structural features through mutagenesis can be a challenging ordeal. Here, we apply a new approach for the expedited protein characterization of the TBDT ShuA from Shigella dysenteriae, and elucidate the protein's initial steps during heme-uptake. ShuA variants were displayed on the surface of an M13 bacteriophage as fusions to the P8 coat protein. Each ShuA variant was analyzed for its ability to display on the bacteriophage surface, and functionally bind to hemoglobin. This technique streamlines isolation of stable MP variants for rapid characterization of binding to various ligands. Site-directed mutagenesis studies targeting each extracellular loop region of ShuA demonstrate no specific extracellular loop is required for hemoglobin binding. Instead two residues, His420 and His86 mediate this interaction. The results identify a loop susceptible to antibody binding, and also a small molecule motif capable of disrupting ShuA from S. dysenteriae. The approach is generalizable to the dissection of other phage-displayed TBDTs and MPs.
Wachter, S. Blake; Johnson, Ken; Albert, Robert; Syroid, Noah; Drews, Frank; Westenskow, Dwayne
2006-01-01
Objective Authors developed a picture-graphics display for pulmonary function to present typical respiratory data used in perioperative and intensive care environments. The display utilizes color, shape and emergent alerting to highlight abnormal pulmonary physiology. The display serves as an adjunct to traditional operating room displays and monitors. Design To evaluate the prototype, nineteen clinician volunteers each managed four adverse respiratory events and one normal event using a high-resolution patient simulator which included the new displays (intervention subjects) and traditional displays (control subjects). Between-group comparisons included (i) time to diagnosis and treatment for each adverse respiratory event; (ii) the number of unnecessary treatments during the normal scenario; and (iii) self-reported workload estimates while managing study events. Measurements Two expert anesthesiologists reviewed video-taped transcriptions of the volunteers to determine time to treat and time to diagnosis. Time values were then compared between groups using a Mann-Whitney-U Test. Estimated workload for both groups was assessed using the NASA-TLX and compared between groups using an ANOVA. P-values < 0.05 were considered significant. Results Clinician volunteers detected and treated obstructed endotracheal tubes and intrinsic PEEP problems faster with graphical rather than conventional displays (p < 0.05). During the normal scenario simulation, 3 clinicians using the graphical display, and 5 clinicians using the conventional display gave unnecessary treatments. Clinician-volunteers reported significantly lower subjective workloads using the graphical display for the obstructed endotracheal tube scenario (p < 0.001) and the intrinsic PEEP scenario (p < 0.03). Conclusion Authors conclude that the graphical pulmonary display may serve as a useful adjunct to traditional displays in identifying adverse respiratory events. PMID:16929038
Sinha, Mau; Kaushik, Sanket; Kaur, Punit; Singh, Tej P.
2013-01-01
Lactoferrin is a multifunctional, iron-binding glycoprotein which displays a wide array of modes of action to execute its primary antimicrobial function. It contains various antimicrobial peptides which are released upon its hydrolysis by proteases. These peptides display a similarity with the antimicrobial cationic peptides found in nature. In the current scenario of increasing resistance to antibiotics, there is a need for the discovery of novel antimicrobial drugs. In this context, the structural and functional perspectives on some of the antimicrobial peptides found in N-lobe of lactoferrin have been reviewed. This paper provides the comparison of lactoferrin peptides with other antimicrobial peptides found in nature as well as interspecies comparison of the structural properties of these peptides within the native lactoferrin. PMID:23554820
A system for the real-time display of radar and video images of targets
NASA Technical Reports Server (NTRS)
Allen, W. W.; Burnside, W. D.
1990-01-01
Described here is a software and hardware system for the real-time display of radar and video images for use in a measurement range. The main purpose is to give the reader a clear idea of the software and hardware design and its functions. This system is designed around a Tektronix XD88-30 graphics workstation, used to display radar images superimposed on video images of the actual target. The system's purpose is to provide a platform for tha analysis and documentation of radar images and their associated targets in a menu-driven, user oriented environment.
A Cost-Effective Energy-Recovering Sustain Driving Circuit for ac Plasma Display Panels
NASA Astrophysics Data System (ADS)
Lim, Jae Kwang; Tae, Heung-Sik; Choi, Byungcho; Kim, Seok Gi
A new sustain driving circuit, featuring an energy-recovering function with simple structure and minimal component count, is proposed as a cost-effective solution for driving plasma display panels during the sustaining period. Compared with existing solutions, the proposed circuit reduces the number of semiconductor switches and reactive circuit components without compromising the circuit performance and gas-discharging characteristics. In addition, the proposed circuit utilizes the harness wire as an inductive circuit component, thereby further simplifying the circuit structure. The performance of the proposed circuit is confirmed with a 42-inch plasma display panel.
A new model of the distal convoluted tubule
Ko, Benjamin; Mistry, Abinash C.; Hanson, Lauren; Mallick, Rickta; Cooke, Leslie L.; Hack, Bradley K.; Cunningham, Patrick
2012-01-01
The Na+-Cl− cotransporter (NCC) in the distal convoluted tubule (DCT) of the kidney is a key determinant of Na+ balance. Disturbances in NCC function are characterized by disordered volume and blood pressure regulation. However, many details concerning the mechanisms of NCC regulation remain controversial or undefined. This is partially due to the lack of a mammalian cell model of the DCT that is amenable to functional assessment of NCC activity. Previously reported investigations of NCC regulation in mammalian cells have either not attempted measurements of NCC function or have required perturbation of the critical without a lysine kinase (WNK)/STE20/SPS-1-related proline/alanine-rich kinase regulatory pathway before functional assessment. Here, we present a new mammalian model of the DCT, the mouse DCT15 (mDCT15) cell line. These cells display native NCC function as measured by thiazide-sensitive, Cl−-dependent 22Na+ uptake and allow for the separate assessment of NCC surface expression and activity. Knockdown by short interfering RNA confirmed that this function was dependent on NCC protein. Similar to the mammalian DCT, these cells express many of the known regulators of NCC and display significant baseline activity and dimerization of NCC. As described in previous models, NCC activity is inhibited by appropriate concentrations of thiazides, and phorbol esters strongly suppress function. Importantly, they display release of WNK4 inhibition of NCC by small hairpin RNA knockdown. We feel that this new model represents a critical tool for the study of NCC physiology. The work that can be accomplished in such a system represents a significant step forward toward unraveling the complex regulation of NCC. PMID:22718890
Synthetic Phage for Tissue Regeneration
Merzlyak, Anna; Lee, Seung-Wuk
2014-01-01
Controlling structural organization and signaling motif display is of great importance to design the functional tissue regenerating materials. Synthetic phage, genetically engineered M13 bacteriophage has been recently introduced as novel tissue regeneration materials to display a high density of cell-signaling peptides on their major coat proteins for tissue regeneration purposes. Structural advantages of their long-rod shape and monodispersity can be taken together to construct nanofibrous scaffolds which support cell proliferation and differentiation as well as direct orientation of their growth in two or three dimensions. This review demonstrated how functional synthetic phage is designed and subsequently utilized for tissue regeneration that offers potential cell therapy. PMID:24991085
Left ventricular pressure and volume data acquisition and analysis using LabVIEW.
Cassidy, S C; Teitel, D F
1997-03-01
To automate analysis of left ventricular pressure-volume data, we used LabVIEW to create applications that digitize and display data recorded from conductance and manometric catheters. Applications separate data into cardiac cycles, calculate parallel conductance, and calculate indices of left ventricular function, including end-systolic elastance, preload-recruitable stroke work, stroke volume, ejection fraction, stroke work, maximum and minimum derivative of ventricular pressure, heart rate, indices of relaxation, peak filling rate, and ventricular chamber stiffness. Pressure-volume loops can be graphically displayed. These analyses are exported to a text-file. These applications have simplified and automated the process of evaluating ventricular function.
Romantic love and sexual desire in close relationships.
Gonzaga, Gian C; Turner, Rebecca A; Keltner, Dacher; Campos, Belinda; Altemus, Margaret
2006-05-01
Drawing on recent claims in the study of relationships, attachment, and emotion, the authors hypothesized that romantic love serves a commitment-related function and sexual desire a reproduction-related function. Consistent with these claims, in Study 1, brief experiences of romantic love and sexual desire observed in a 3-min interaction between romantic partners were related to distinct feeling states, distinct nonverbal displays, and commitment- and reproductive-related relationship outcomes, respectively. In Study 2, the nonverbal display of romantic love was related to the release of oxytocin. Discussion focuses on the place of romantic love and sexual desire in the literature on emotion. 2006 APA, all rights reserved
Rhythmic displays of female gibbons offer insight into the origin of dance
Fan, Peng-Fei; Ma, Chang-Yong; Garber, Paul A.; Zhang, Wen; Fei, Han-Lan; Xiao, Wen
2016-01-01
Dance is a universal art form practiced by all human societies and has many functions including sexual attraction, social cohesion, and the therapeutic release of energy. Dance also has been reported in a small number of non-human primate species, in particular apes. However, its function has not been systematically evaluated. We observed 357 intentional, rhythmic, and nonverbal dance displays performed by four adult female cao vit gibbons (Nomascus nasutus) residing in four polygynous groups during 3000 h of observation in Bangliang, Guangxi, China. Females used dance to solicit copulations, as well as to promote a social bond with the group’s lone adult male. In addition, this display appears to represent a form of non-aggressive competition among adult females living in the same group. We found that a female who had a weaker social relationship with the breeding male increased her social and sexual access to the male by an increase in dancing frequency. Given that gibbons dance in various behavioral contexts, and appears to serve several important social and sexual functions, a greater understanding of this form of gestural communication offers an instructive model for examining the origin and evolution of dance in humans and other apes. PMID:27687686
Rhythmic displays of female gibbons offer insight into the origin of dance.
Fan, Peng-Fei; Ma, Chang-Yong; Garber, Paul A; Zhang, Wen; Fei, Han-Lan; Xiao, Wen
2016-09-30
Dance is a universal art form practiced by all human societies and has many functions including sexual attraction, social cohesion, and the therapeutic release of energy. Dance also has been reported in a small number of non-human primate species, in particular apes. However, its function has not been systematically evaluated. We observed 357 intentional, rhythmic, and nonverbal dance displays performed by four adult female cao vit gibbons (Nomascus nasutus) residing in four polygynous groups during 3000 h of observation in Bangliang, Guangxi, China. Females used dance to solicit copulations, as well as to promote a social bond with the group's lone adult male. In addition, this display appears to represent a form of non-aggressive competition among adult females living in the same group. We found that a female who had a weaker social relationship with the breeding male increased her social and sexual access to the male by an increase in dancing frequency. Given that gibbons dance in various behavioral contexts, and appears to serve several important social and sexual functions, a greater understanding of this form of gestural communication offers an instructive model for examining the origin and evolution of dance in humans and other apes.
Bruning, Marc; Kreplak, Laurent; Leopoldseder, Sonja; Müller, Shirley A; Ringler, Philippe; Duchesne, Laurence; Fernig, David G; Engel, Andreas; Ucurum-Fotiadis, Zöhre; Mayans, Olga
2010-11-10
The development of biomatrices for technological and biomedical applications employs self-assembled scaffolds built from short peptidic motifs. However, biopolymers composed of protein domains would offer more varied molecular frames to introduce finer and more complex functionalities in bioreactive scaffolds using bottom-up approaches. Yet, the rules governing the three-dimensional organization of protein architectures in nature are complex and poorly understood. As a result, the synthetic fabrication of ordered protein association into polymers poses major challenges to bioengineering. We have now fabricated a self-assembling protein nanofiber with predictable morphologies and amenable to bottom-up customization, where features supporting function and assembly are spatially segregated. The design was inspired by the cross-linking of titin filaments by telethonin in the muscle sarcomere. The resulting fiber is a two-protein system that has nanopatterned peptide display capabilities as shown by the recruitment of functionalized gold nanoparticles at regular intervals of ∼ 5 nm, yielding a semiregular linear array over micrometers. This polymer promises the uncomplicated display of biologically active motifs to selectively bind and organize matter in the fine nanoscale. Further, its conceptual design has high potential for controlled plurifunctionalization.
76 FR 73006 - General Motors, LLC, Grant of Petition for Decision of Inconsequential Noncompliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-28
... the rarest circumstances, the primary function of the PRNDM display is to inform the driver of gear... of shifting errors.'' In all but the rarest circumstances, the primary function of the transmission...
Augmenting digital displays with computation
NASA Astrophysics Data System (ADS)
Liu, Jing
As we inevitably step deeper and deeper into a world connected via the Internet, more and more information will be exchanged digitally. Displays are the interface between digital information and each individual. Naturally, one fundamental goal of displays is to reproduce information as realistically as possible since humans still care a lot about what happens in the real world. Human eyes are the receiving end of such information exchange; therefore it is impossible to study displays without studying the human visual system. In fact, the design of displays is rather closely coupled with what human eyes are capable of perceiving. For example, we are less interested in building displays that emit light in the invisible spectrum. This dissertation explores how we can augment displays with computation, which takes both display hardware and the human visual system into consideration. Four novel projects on display technologies are included in this dissertation: First, we propose a software-based approach to driving multiview autostereoscopic displays. Our display algorithm can dynamically assign views to hardware display zones based on multiple observers' current head positions, substantially reducing crosstalk and stereo inversion. Second, we present a dense projector array that creates a seamless 3D viewing experience for multiple viewers. We smoothly interpolate the set of viewer heights and distances on a per-vertex basis across the arrays field of view, reducing image distortion, crosstalk, and artifacts from tracking errors. Third, we propose a method for high dynamic range display calibration that takes into account the variation of the chrominance error over luminance. We propose a data structure for enabling efficient representation and querying of the calibration function, which also allows user-guided balancing between memory consumption and the amount of computation. Fourth, we present user studies that demonstrate that the ˜ 60 Hz critical flicker fusion rate for traditional displays is not enough for some computational displays that show complex image patterns. The study focuses on displays with hidden channels, and their application to 3D+2D TV. By taking advantage of the fast growing power of computation and sensors, these four novel display setups - in combination with display algorithms - advance the frontier of computational display research.
Trinucleotide cassettes increase diversity of T7 phage-displayed peptide library.
Krumpe, Lauren R H; Schumacher, Kathryn M; McMahon, James B; Makowski, Lee; Mori, Toshiyuki
2007-10-05
Amino acid sequence diversity is introduced into a phage-displayed peptide library by randomizing library oligonucleotide DNA. We recently evaluated the diversity of peptide libraries displayed on T7 lytic phage and M13 filamentous phage and showed that T7 phage can display a more diverse amino acid sequence repertoire due to differing processes of viral morphogenesis. In this study, we evaluated and compared the diversity of a 12-mer T7 phage-displayed peptide library randomized using codon-corrected trinucleotide cassettes with a T7 and an M13 12-mer phage-displayed peptide library constructed using the degenerate codon randomization method. We herein demonstrate that the combination of trinucleotide cassette amino acid codon randomization and T7 phage display construction methods resulted in a significant enhancement to the functional diversity of a 12-mer peptide library. This novel library exhibited superior amino acid uniformity and order-of-magnitude increases in amino acid sequence diversity as compared to degenerate codon randomized peptide libraries. Comparative analyses of the biophysical characteristics of the 12-mer peptide libraries revealed the trinucleotide cassette-randomized library to be a unique resource. The combination of T7 phage display and trinucleotide cassette randomization resulted in a novel resource for the potential isolation of binding peptides for new and previously studied molecular targets.
LCD displays performance comparison by MTF measurement using the white noise stimulus method
NASA Astrophysics Data System (ADS)
Mitjà, Carles; Escofet, Jaume
2011-01-01
The amount of images produced to be viewed as soft copies on output displays are significantly increasing. This growing occurs at the expense of the images targeted to hard copy versions on paper or any other physical support. Even in the case of high quality hard copy production, people working in professional imaging uses different displays in selecting, editing, processing and showing images, from laptop screen to specialized high end displays. Then, the quality performance of these devices is crucial in the chain of decisions to be taken in image production. Metrics of this quality performance can help in the equipment acquisition. Different metrics and methods have been described to determine the quality performance of CRT and LCD computer displays in clinical area. One of most important metrics in this field is the device spatial frequency response obtained measuring the modulation transfer function (MTF). This work presents a comparison between the MTF of three different LCD displays, Apple MacBook Pro 15", Apple LED Cinema Display 24" and Apple iPhone4, measured by the white noise stimulus method, over vertical and horizontal directions. Additionally, different displays show particular pixels structure pattern. In order to identify this pixel structure, a set of high magnification images is taken from each display to be related with the respective vertical and horizontal MTF.
Optimization of the polyplanar optical display electronics for a monochrome B-52 display
NASA Astrophysics Data System (ADS)
DeSanto, Leonard
1998-09-01
The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. The prototype ten-inch display is two inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. In order to achieve a long lifetime, the new display uses a new 200 mW green solid-state laser (10,000 hr. life) at 532 nm as its light source. To produce real-time video, the laser light is being modulated by a Digital Light Processing (DLPTM) chip manufactured by Texas Instruments (TI). In order to use the solid-state laser as the light source and also fit within the constraints of the B-52 display, the Digital Micromirror Device (DMDTM) chip is operated remotely from the Texas Instruments circuit board. In order to achieve increased brightness a monochrome digitizing interface was investigated. The operation of the DMDTM divorced from the light engine and the interfacing of the DMDTM board with the RS-170 video format specific to the B-52 aircraft will be discussed, including the increased brightness of the monochrome digitizing interface. A brief description of the electronics required to drive the new 200 mW laser is also presented.
Yeast cell surface display for lipase whole cell catalyst and its applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yun; Zhang, Rui; Lian, Zhongshuai
The cell surface display technique allows for the expression of target proteins or peptides on the microbial cell surface by fusing an appropriate protein as an anchoring motif. Yeast display systems, such as Pichia pastoris, Yarowia lipolytica and Saccharomyces cerevisiae, are ideal, alternative and extensive display systems with the advantage of simple genetic manipulation and post-translational modification of expressed heterologous proteins. Engineered yeasts show high performance characteristics and variant utilizations. Herein, we comprehensively summarize the variant factors affecting lipase whole cell catalyst activity and display efficiency, including the structure and size of target proteins, screening anchor proteins, type and chainmore » length of linkers, and the appropriate matching rules among the above-mentioned display units. Furthermore, we also address novel approaches to enhance stability and activity of recombinant lipases, such as VHb gene co-expression, multi-enzyme co-display technique, and the micro-environmental interference and self-assembly techniques. Finally, we represent the variety of applications of whole cell surface displayed lipases on yeast cells in non-aqueous phases, including synthesis of esters, PUFA enrichment, resolution of chiral drugs, organic synthesis and biofuels. We demonstrate that the lipase surface display technique is a powerful tool for functionalizing yeasts to serve as whole cell catalysts, and increasing interest is providing an impetus for broad application of this technique.« less
Flight tests of the 4D flight guidance display
NASA Astrophysics Data System (ADS)
Below, Christian; von Viebahn, Harro; Purpus, Matthias
1997-06-01
A perspective primary flight and a navigation display format were evaluated in a flying testbed. The flight tests comprised ILS- and standard approaches as well as low level operations utilizing the depiction of a spatial channel, and demonstrations of the inherent ground proximity warning function. In the cockpit of the VFW614, the left seat was equipped with a sidestick and a flat panel display, which showed both the 4D-display an the Navigation Display format. Airline and airforce pilots flew several missions each. Although most of the pilots criticizes that a typical flight director commanding the aircraft's attitude was missing, they could follow the channel precisely. However, some airline pilots stated a lack of vertical guidance information during the final approach. Leaving and re- entering the channel could be easily accomplished form any direction. In summary pilots' assessment of the display concept yielded an overall improvement of SA. In particular it was stated that displays are an appropriate means to avoid CFIT accidents. With the fist prototypes of 3D- graphics generators designed for avionics available the flight evaluation will continue including feasibility demonstrations of high-performance graphics for civil and military aircraft applications.
Prygun, A V; Lazarev, N V
1998-10-01
Radiation measuring on the work places of operators in command and control installations proved that environment parameters depending on electronic display functioning are in line with the regulations' requirements. Nevertheless the operator health estimates show that the problem of personnel security still exists. The authors recommend some measures to improve the situation.
Design of see-through near-eye display for presbyopia.
Wu, Yishi; Chen, Chao Ping; Zhou, Lei; Li, Yang; Yu, Bing; Jin, Huayi
2017-04-17
We propose a compact design of see-through near-eye display that is dedicated to presbyopia. Our solution is characterized by a plano-convex waveguide, which is essentially an integration of a corrective lens and two volume holograms. Its design rules are set forth in detail, followed by the results and discussion regarding the diffraction efficiency, field of view, modulation transfer function, distortion, and simulated imaging.
Piloted evaluation of an integrated propulsion and flight control simulator
NASA Technical Reports Server (NTRS)
Bright, Michelle M.; Simon, Donald L.
1992-01-01
A piloted evaluation of the integrated flight and propulsion control simulator for advanced integrated propulsion and airframe control design is described. The evaluation will cover control effector gains and deadbands, control effectiveness and control authority, and heads up display functionality. For this evaluation the flight simulator is configured for transition flight using an advanced Short Take-Off and Vertical Landing fighter aircraft model, a simplified high-bypass turbofan engine model, fighter cockpit displays, and pilot effectors. The piloted tasks used for rating displays and control effector gains are described. Pilot comments and simulation results confirm that the display symbology and control gains are very adequate for the transition flight task. Additionally, it is demonstrated that this small-scale, fixed base flight simulator facility can adequately perform a real time, piloted control evaluation.
Junction-based field emission structure for field emission display
Dinh, Long N.; Balooch, Mehdi; McLean, II, William; Schildbach, Marcus A.
2002-01-01
A junction-based field emission display, wherein the junctions are formed by depositing a semiconducting or dielectric, low work function, negative electron affinity (NEA) silicon-based compound film (SBCF) onto a metal or n-type semiconductor substrate. The SBCF can be doped to become a p-type semiconductor. A small forward bias voltage is applied across the junction so that electron transport is from the substrate into the SBCF region. Upon entering into this NEA region, many electrons are released into the vacuum level above the SBCF surface and accelerated toward a positively biased phosphor screen anode, hence lighting up the phosphor screen for display. To turn off, simply switch off the applied potential across the SBCF/substrate. May be used for field emission flat panel displays.
The Use of Interactive Raster Graphics in the Display and Manipulation of Multidimensional Data
NASA Technical Reports Server (NTRS)
Anderson, D. C.
1981-01-01
Techniques for the review, display, and manipulation of multidimensional data are developed and described. Multidimensional data is meant in this context to describe scalar data associated with a three dimensional geometry or otherwise too complex to be well represented by traditional graphs. Raster graphics techniques are used to display a shaded image of a three dimensional geometry. The use of color to represent scalar data associated with the geometries in shaded images is explored. Distinct hues are associated with discrete data ranges, thus emulating the traditional representation of data with isarithms, or lines of constant numerical value. Data ranges are alternatively associated with a continuous spectrum of hues to show subtler data trends. The application of raster graphics techniques to the display of bivariate functions is explored.
NASA Technical Reports Server (NTRS)
Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.
2015-01-01
A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the development of DAA display performance standards, as well as the need for future research are discussed.
Swerdlow, Russell H.
2012-01-01
Several sporadic neurodegenerative diseases display phenomena that directly or indirectly relate to mitochondrial function. Data suggesting altered mitochondrial function in these diseases could arise from mitochondrial DNA (mtDNA) are reviewed. Approaches for manipulating mitochondrial function and minimizing the downstream consequences of mitochondrial dysfunction are discussed. PMID:21902672
ERIC Educational Resources Information Center
Lyons, Elizabeth A.; Rue, Hanna C.; Luiselli, James K.; DiGennaro, Florence D.
2007-01-01
Rumination is a serious problem demonstrated by some people with developmental disabilities, but previous research has not included a functional analysis and has rarely compared intervention methods during the assessment process. We conducted functional analyses with 2 children who displayed postmeal rumination and subsequently evaluated a…
Identifying functional communities for use in forest planning and decisionmaking
Pamela J. Jakes; Thomas E. Fish
1998-01-01
Public land managers are searching for frameworks for organizing and displaying social information that will make it useful in forest management and decisionmaking. On the Chequamegon-Nicolet National Forests in Wisconsin, managers and researchers have used the concept of functional communities to develop such a framework. Functional communities define geographic areas...
Shechner, David M.; Hacisüleyman, Ezgi; Younger, Scott T.; Rinn, John L.
2016-01-01
Noncoding RNAs (ncRNAs) comprise an important class of regulatory molecules that mediate a vast array of biological processes. This broad functional capacity has also facilitated the design of artificial ncRNAs with novel functions. To further investigate and harness these capabilities, we developed CRISPR-Display (“CRISP-Disp”), a targeted localization method that uses Sp. Cas9 to deploy large RNA cargos to DNA loci. We demonstrate that exogenous RNA domains can be functionally appended onto the CRISPR scaffold at multiple insertion points, allowing the construction of Cas9 complexes with protein-binding cassettes, artificial aptamers, pools of random sequences, and RNAs up to 4.8 kilobases in length, including natural lncRNAs. Unlike most existing CRISPR methods, CRISP-Disp allows simultaneous multiplexing of distinct functions at multiple targets, limited only by the number of available functional RNA motifs. We anticipate that this technology will provide a powerful method with which to ectopically localize functional RNAs and ribonucleoprotein (RNP) complexes at specified genomic loci. PMID:26030444
Adaptive controller for volumetric display of neuroimaging studies
NASA Astrophysics Data System (ADS)
Bleiberg, Ben; Senseney, Justin; Caban, Jesus
2014-03-01
Volumetric display of medical images is an increasingly relevant method for examining an imaging acquisition as the prevalence of thin-slice imaging increases in clinical studies. Current mouse and keyboard implementations for volumetric control provide neither the sensitivity nor specificity required to manipulate a volumetric display for efficient reading in a clinical setting. Solutions to efficient volumetric manipulation provide more sensitivity by removing the binary nature of actions controlled by keyboard clicks, but specificity is lost because a single action may change display in several directions. When specificity is then further addressed by re-implementing hardware binary functions through the introduction of mode control, the result is a cumbersome interface that fails to achieve the revolutionary benefit required for adoption of a new technology. We address the specificity versus sensitivity problem of volumetric interfaces by providing adaptive positional awareness to the volumetric control device by manipulating communication between hardware driver and existing software methods for volumetric display of medical images. This creates a tethered effect for volumetric display, providing a smooth interface that improves on existing hardware approaches to volumetric scene manipulation.
Digital Image Display Control System, DIDCS. [for astronomical analysis
NASA Technical Reports Server (NTRS)
Fischel, D.; Klinglesmith, D. A., III
1979-01-01
DIDCS is an interactive image display and manipulation system that is used for a variety of astronomical image reduction and analysis operations. The hardware system consists of a PDP 11/40 main frame with 32K of 16-bit core memory; 96K of 16-bit MOS memory; two 9 track 800 BPI tape drives; eight 2.5 million byte RKO5 type disk packs, three user terminals, and a COMTAL 8000-S display system which has sufficient memory to store and display three 512 x 512 x 8 bit images along with an overlay plane and function table for each image, a pseudo color table and the capability for displaying true color. The software system is based around the language FORTH, which will permit an open ended dictionary of user level words for image analyses and display. A description of the hardware and software systems will be presented along with examples of the types of astronomical research that are being performed. Also a short discussion of the commonality and exchange of this type of image analysis system will be given.
Visual effects in great bowerbird sexual displays and their implications for signal design.
Endler, John A; Gaburro, Julie; Kelley, Laura A
2014-05-22
It is often assumed that the primary purpose of a male's sexual display is to provide information about quality, or to strongly stimulate prospective mates, but other functions of courtship displays have been relatively neglected. Male great bowerbirds (Ptilonorhynchus nuchalis) construct bowers that exploit the female's predictable field of view (FOV) during courtship displays by creating forced perspective illusions, and the quality of illusion is a good predictor of mating success. Here, we present and discuss two additional components of male courtship displays that use the female's predetermined viewpoint: (i) the rapid and diverse flashing of coloured objects within her FOV and (ii) chromatic adaptation of the female's eyes that alters her perception of the colour of the displayed objects. Neither is directly related to mating success, but both are likely to increase signal efficacy, and may also be associated with attracting and holding the female's attention. Signal efficacy is constrained by trade-offs between the signal components; there are both positive and negative interactions within multicomponent signals. Important signal components may have a threshold effect on fitness rather than the often assumed linear relationship.
Flatbed-type 3D display systems using integral imaging method
NASA Astrophysics Data System (ADS)
Hirayama, Yuzo; Nagatani, Hiroyuki; Saishu, Tatsuo; Fukushima, Rieko; Taira, Kazuki
2006-10-01
We have developed prototypes of flatbed-type autostereoscopic display systems using one-dimensional integral imaging method. The integral imaging system reproduces light beams similar of those produced by a real object. Our display architecture is suitable for flatbed configurations because it has a large margin for viewing distance and angle and has continuous motion parallax. We have applied our technology to 15.4-inch displays. We realized horizontal resolution of 480 with 12 parallaxes due to adoption of mosaic pixel arrangement of the display panel. It allows viewers to see high quality autostereoscopic images. Viewing the display from angle allows the viewer to experience 3-D images that stand out several centimeters from the surface of the display. Mixed reality of virtual 3-D objects and real objects are also realized on a flatbed display. In seeking reproduction of natural 3-D images on the flatbed display, we developed proprietary software. The fast playback of the CG movie contents and real-time interaction are realized with the aid of a graphics card. Realization of the safety 3-D images to the human beings is very important. Therefore, we have measured the effects on the visual function and evaluated the biological effects. For example, the accommodation and convergence were measured at the same time. The various biological effects are also measured before and after the task of watching 3-D images. We have found that our displays show better results than those to a conventional stereoscopic display. The new technology opens up new areas of application for 3-D displays, including arcade games, e-learning, simulations of buildings and landscapes, and even 3-D menus in restaurants.
Consultant management estimating tool : users' manual.
DOT National Transportation Integrated Search
2012-04-01
The Switchboard is the opening form displayed to users. Use : the Switchboard to access the main functions of the estimating : tool. Double-click on a box to select the desired function. From : the Switchboard a user can initiate a search for project...
Examining Functions in Mathematics and Science Using Computer Interfacing.
ERIC Educational Resources Information Center
Walton, Karen Doyle
1988-01-01
Introduces microcomputer interfacing as a method for explaining and demonstrating various aspects of the concept of function. Provides three experiments with illustrations and typical computer graphic displays: pendulum motion, pendulum study using two pendulums, and heat absorption and radiation. (YP)
Romao, Ema; Morales-Yanez, Francisco; Hu, Yaozhong; Crauwels, Maxine; De Pauw, Pieter; Hassanzadeh, Gholamreza Ghassanzadeh; Devoogdt, Nick; Ackaert, Chloe; Vincke, Cecile; Muyldermans, Serge
2016-01-01
The discovery of functional heavy chain-only antibodies devoid of light chains in sera of camelids and sharks in the early nineties provided access to the generation of minimal-sized, single-domain, in vivo affinity-matured, recombinant antigenbinding fragments, also known as Nanobodies. Recombinant DNA technology and adaptation of phage display vectors form the basis to construct large naïve, synthetic or medium sized immune libraries from where multiple Nanobodies have been retrieved. Alternative selection methods (i.e. bacterial display, bacterial two-hybrid, Cis-display and ribosome display) have also been developed to identify Nanobodies. The antigen affinity, stability, expression yields and structural details of the Nanobodies have been determined by standard technology. Nanobodies were subsequently engineered for higher stability and affinity, to have a sequence closer to that of human immunoglobulin domains, or to add designed effector functions. Antigen specific Nanobodies recognizing with high affinity their cognate antigen were retrieved from various libraries. High expression yields are obtained from microorganisms, even when expressed in the cytoplasm. The purified Nanobodies are shown to possess beneficial biochemical and biophysical properties. The crystal structure of Nanobody::antigen complexes reveal the preference of Nanobodies for cavities on the antigen surface. Thanks to the properties described above, Nanobodies became a highly valued and versatile tool for biomolecular research. Moreover, numerous diagnostic and therapeutic Nanobody-based applications have been developed in the past decade. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Evanoff, M G; Roehrig, H; Giffords, R S; Capp, M P; Rovinelli, R J; Hartmann, W H; Merritt, C
2001-06-01
This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.
Baculovirus display of functional antibody Fab fragments.
Takada, Shinya; Ogawa, Takafumi; Matsui, Kazusa; Suzuki, Tasuku; Katsuda, Tomohisa; Yamaji, Hideki
2015-08-01
The generation of a recombinant baculovirus that displays antibody Fab fragments on the surface was investigated. A recombinant baculovirus was engineered so that the heavy chain (Hc; Fd fragment) of a mouse Fab fragment was expressed as a fusion to the N-terminus of baculovirus gp64, while the light chain of the Fab fragment was simultaneously expressed as a secretory protein. Following infection of Sf9 insect cells with the recombinant baculovirus, the culture supernatant was analyzed by enzyme-linked immunosorbent assay using antigen-coated microplates and either an anti-mouse IgG or an anti-gp64 antibody. A relatively strong signal was obtained in each case, showing antigen-binding activity in the culture supernatant. In western blot analysis of the culture supernatant using the anti-gp64 antibody, specific protein bands were detected at an electrophoretic mobility that coincided with the molecular weight of the Hc-gp64 fusion protein as well as that of gp64. Flow cytometry using a fluorescein isothiocyanate-conjugated antibody specific to mouse IgG successfully detected the Fab fragments on the surface of the Sf9 cells. These results suggest that immunologically functional antibody Fab fragments can be displayed on the surface of baculovirus particles, and that a fluorescence-activated cell sorter with a fluorescence-labeled antigen can isolate baculoviruses displaying specific Fab fragments. This successful baculovirus display of antibody Fab fragments may offer a novel approach for the efficient selection of specific antibodies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokurei, S; Department of Radiology, Yamaguchi University Hospital, Ube, Yamaguchi; Morishita, J
2015-06-15
Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters weremore » computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.« less
Different Signal Enhancement Pathways of Attention and Consciousness Underlie Perception in Humans.
van Boxtel, Jeroen J A
2017-06-14
It is not yet known whether attention and consciousness operate through similar or largely different mechanisms. Visual processing mechanisms are routinely characterized by measuring contrast response functions (CRFs). In this report, behavioral CRFs were obtained in humans (both males and females) by measuring afterimage durations over the entire range of inducer stimulus contrasts to reveal visual mechanisms behind attention and consciousness. Deviations relative to the standard CRF, i.e., gain functions, describe the strength of signal enhancement, which were assessed for both changes due to attentional task and conscious perception. It was found that attention displayed a response-gain function, whereas consciousness displayed a contrast-gain function. Through model comparisons, which only included contrast-gain modulations, both contrast-gain and response-gain effects can be explained with a two-level normalization model, in which consciousness affects only the first level and attention affects only the second level. These results demonstrate that attention and consciousness can effectively show different gain functions because they operate through different signal enhancement mechanisms. SIGNIFICANCE STATEMENT The relationship between attention and consciousness is still debated. Mapping contrast response functions (CRFs) has allowed (neuro)scientists to gain important insights into the mechanistic underpinnings of visual processing. Here, the influence of both attention and consciousness on these functions were measured and they displayed a strong dissociation. First, attention lowered CRFs, whereas consciousness raised them. Second, attention manifests itself as a response-gain function, whereas consciousness manifests itself as a contrast-gain function. Extensive model comparisons show that these results are best explained in a two-level normalization model in which consciousness affects only the first level, whereas attention affects only the second level. These findings show dissociations between both the computational mechanisms behind attention and consciousness and the perceptual consequences that they induce. Copyright © 2017 the authors 0270-6474/17/375912-11$15.00/0.
Space Shuttle avionics upgrade - Issues and opportunities
NASA Astrophysics Data System (ADS)
Swaim, Richard A.; Wingert, William B.
An overview is conducted of existing Space Shuttle avionics and the possibilities for upgrading the cockpit to reduce costs and increase functionability. The current avionics include five general-purpose computers fitted with multifunction displays, dedicated switches and indicators, and dedicated flight instruments. The operational needs of the Shuttle are reviewed in the light of the avionics and potential upgrades in the form of microprocessors and display systems. The use of better processors can provide hardware support for multitasking and memory management and can reduce the life-cycle cost for software. Some limitations of the current technology are acknowledged including the Shuttle's power budget and structural configuration. A phased infusion of upgraded avionics is proposed that provides a functionally transparent replacement of crew-interface equipment as well as the addition of interface enhancements and the migration of selected functions.
In-Vehicle Signing Functions of an In-Vehicle Information System
DOT National Transportation Integrated Search
1996-01-01
The definition of In-Vehicle Signing (IVS) functions was guided by the principles of traffic engineering as they apply to the design and placement of roadway signs. Because of the dynamic and active nature of computing, communications, and display te...
Controlled surface functionality of magnetic nanoparticles by layer-by-layer assembled nano-films
NASA Astrophysics Data System (ADS)
Choi, Daheui; Son, Boram; Park, Tai Hyun; Hong, Jinkee
2015-04-01
Over the past several years, the preparation of functionalized nanoparticles has been aggressively pursued in order to develop desired structures, compositions, and structural order. Among the various nanoparticles, iron oxide magnetic nanoparticles (MNPs) have shown great promise because the material generated using these MNPs can be used in a variety of biomedical applications and possible bioactive functionalities. In this study, we report the development of various functionalized MNPs (F-MNPs) generated using the layer-by-layer (LbL) self-assembly method. To provide broad functional opportunities, we fabricated F-MNP bio-toolbox by using three different materials: synthetic polymers, natural polymers, and carbon materials. Each of these F-MNPs displays distinct properties, such as enhanced thickness or unique morphologies. In an effort to explore their biomedical applications, we generated basic fibroblast growth factor (bFGF)-loaded F-MNPs. The bFGF-loaded F-MNPs exhibited different release mechanisms and loading amounts, depending on the film material and composition order. Moreover, bFGF-loaded F-MNPs displayed higher biocompatibility and possessed superior proliferation properties than the bare MNPs and pure bFGF, respectively. We conclude that by simply optimizing the building materials and the nanoparticle's film composition, MNPs exhibiting various bioactive properties can be generated.Over the past several years, the preparation of functionalized nanoparticles has been aggressively pursued in order to develop desired structures, compositions, and structural order. Among the various nanoparticles, iron oxide magnetic nanoparticles (MNPs) have shown great promise because the material generated using these MNPs can be used in a variety of biomedical applications and possible bioactive functionalities. In this study, we report the development of various functionalized MNPs (F-MNPs) generated using the layer-by-layer (LbL) self-assembly method. To provide broad functional opportunities, we fabricated F-MNP bio-toolbox by using three different materials: synthetic polymers, natural polymers, and carbon materials. Each of these F-MNPs displays distinct properties, such as enhanced thickness or unique morphologies. In an effort to explore their biomedical applications, we generated basic fibroblast growth factor (bFGF)-loaded F-MNPs. The bFGF-loaded F-MNPs exhibited different release mechanisms and loading amounts, depending on the film material and composition order. Moreover, bFGF-loaded F-MNPs displayed higher biocompatibility and possessed superior proliferation properties than the bare MNPs and pure bFGF, respectively. We conclude that by simply optimizing the building materials and the nanoparticle's film composition, MNPs exhibiting various bioactive properties can be generated. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr07373h
Prospective identification of parasitic sequences in phage display screens
Matochko, Wadim L.; Cory Li, S.; Tang, Sindy K.Y.; Derda, Ratmir
2014-01-01
Phage display empowered the development of proteins with new function and ligands for clinically relevant targets. In this report, we use next-generation sequencing to analyze phage-displayed libraries and uncover a strong bias induced by amplification preferences of phage in bacteria. This bias favors fast-growing sequences that collectively constitute <0.01% of the available diversity. Specifically, a library of 109 random 7-mer peptides (Ph.D.-7) includes a few thousand sequences that grow quickly (the ‘parasites’), which are the sequences that are typically identified in phage display screens published to date. A similar collapse was observed in other libraries. Using Illumina and Ion Torrent sequencing and multiple biological replicates of amplification of Ph.D.-7 library, we identified a focused population of 770 ‘parasites’. In all, 197 sequences from this population have been identified in literature reports that used Ph.D.-7 library. Many of these enriched sequences have confirmed function (e.g. target binding capacity). The bias in the literature, thus, can be viewed as a selection with two different selection pressures: (i) target-binding selection, and (ii) amplification-induced selection. Enrichment of parasitic sequences could be minimized if amplification bias is removed. Here, we demonstrate that emulsion amplification in libraries of ∼106 diverse clones prevents the biased selection of parasitic clones. PMID:24217917
Xiao, Chaowen; Somerville, Chris; Anderson, Charles T
2014-03-01
Pectins are acidic carbohydrates that comprise a significant fraction of the primary walls of eudicotyledonous plant cells. They influence wall porosity and extensibility, thus controlling cell and organ growth during plant development. The regulated degradation of pectins is required for many cell separation events in plants, but the role of pectin degradation in cell expansion is poorly defined. Using an activation tag screen designed to isolate genes involved in wall expansion, we identified a gene encoding a putative polygalacturonase that, when overexpressed, resulted in enhanced hypocotyl elongation in etiolated Arabidopsis thaliana seedlings. We named this gene POLYGALACTURONASE INVOLVED IN EXPANSION1 (PGX1). Plants lacking PGX1 display reduced hypocotyl elongation that is complemented by transgenic PGX1 expression. PGX1 is expressed in expanding tissues throughout development, including seedlings, roots, leaves, and flowers. PGX1-GFP (green fluorescent protein) localizes to the apoplast, and heterologously expressed PGX1 displays in vitro polygalacturonase activity, supporting a function for this protein in apoplastic pectin degradation. Plants either overexpressing or lacking PGX1 display alterations in total polygalacturonase activity, pectin molecular mass, and wall composition and also display higher proportions of flowers with extra petals, suggesting PGX1's involvement in floral organ patterning. These results reveal new roles for polygalacturonases in plant development.
Monkeys preferentially process body information while viewing affective displays.
Bliss-Moreau, Eliza; Moadab, Gilda; Machado, Christopher J
2017-08-01
Despite evolutionary claims about the function of facial behaviors across phylogeny, rarely are those hypotheses tested in a comparative context-that is, by evaluating how nonhuman animals process such behaviors. Further, while increasing evidence indicates that humans make meaning of faces by integrating contextual information, including that from the body, the extent to which nonhuman animals process contextual information during affective displays is unknown. In the present study, we evaluated the extent to which rhesus macaques (Macaca mulatta) process dynamic affective displays of conspecifics that included both facial and body behaviors. Contrary to hypotheses that they would preferentially attend to faces during affective displays, monkeys looked for longest, most frequently, and first at conspecifics' bodies rather than their heads. These findings indicate that macaques, like humans, attend to available contextual information during the processing of affective displays, and that the body may also be providing unique information about affective states. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
"Crypto-Display" in Dual-Mode Metasurfaces by Simultaneous Control of Phase and Spectral Responses.
Yoon, Gwanho; Lee, Dasol; Nam, Ki Tae; Rho, Junsuk
2018-06-26
Although conventional metasurfaces have demonstrated many promising functionalities in light control by tailoring either phase or spectral responses of subwavelength structures, simultaneous control of both responses has not been explored yet. Here, we propose a concept of dual-mode metasurfaces that enables simultaneous control of phase and spectral responses for two kinds of operation modes of transmission and reflection, respectively. In the transmission mode, the dual-mode metasurface acts as conventional metasurfaces by tailoring phase distribution of incident light. In the reflection mode, a reflected colored image is produced under white light illumination. We also experimentally demonstrate a crypto-display as one application of the dual-mode metasurface. The crypto-display looks a normal reflective display under white light illumination but generates a hologram that reveals the encrypted phase information under single-wavelength coherent light illumination. Because two operation modes do not affect each other, the crypto-display can have applications in security techniques.
Three-Dimensional Display Technologies for Anatomical Education: A Literature Review
NASA Astrophysics Data System (ADS)
Hackett, Matthew; Proctor, Michael
2016-08-01
Anatomy is a foundational component of biological sciences and medical education and is important for a variety of clinical tasks. To augment current curriculum and improve students' spatial knowledge of anatomy, many educators, anatomists, and researchers use three-dimensional (3D) visualization technologies. This article reviews 3D display technologies and their associated assessments for anatomical education. In the first segment, the review covers the general function of displays employing 3D techniques. The second segment of the review highlights the use and assessment of 3D technology in anatomical education, focusing on factors such as knowledge gains, student perceptions, and cognitive load. The review found 32 articles on the use of 3D displays in anatomical education and another 38 articles on the assessment of 3D displays. The review shows that the majority (74 %) of studies indicate that the use of 3D is beneficial for many tasks in anatomical education, and that student perceptions are positive toward the technology.
Bacteriophages as scaffolds for bipartite display: designing swiss army knives on a nanoscale.
Molek, Peter; Bratkovič, Tomaž
2015-03-18
Bacteriophages have been exploited as cloning vectors and display vehicles for decades owing to their genetic and structural simplicity. In bipartite display setting, phage takes on the role of a handle to which two modules are attached, each endowing it with specific functionality, much like the Swiss army knife. This concept offers unprecedented potential for phage applications in nanobiotechnology. Here, we compare common phage display platforms and discuss approaches to simultaneously append two or more different (poly)peptides or synthetic compounds to phage coat using genetic fusions, chemical or enzymatic conjugations, and in vitro noncovalent decoration techniques. We also review current reports on design of phage frameworks to link multiple effectors, and their use in diverse scientific disciplines. Bipartite phage display had left its mark in development of biosensors, vaccines, and targeted delivery vehicles. Furthermore, multifunctionalized phages have been utilized to template assembly of inorganic materials and protein complexes, showing promise as scaffolds in material sciences and structural biology, respectively.
Shen, Xin; Javidi, Bahram
2018-03-01
We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.
Development and evaluation of amusement machine using autostereoscopic 3D display
NASA Astrophysics Data System (ADS)
Kawai, Takashi; Shibata, Takashi; Shimizu, Yoichi; Kawata, Mitsuhiro; Suto, Masahiro
2004-05-01
Pachinko is a pinball-like game peculiar to Japan, and is one of the most common pastimes around the country. Recently, with the videogame market contracting, various multimedia technologies have been introduced into Pachinko machines. The authors have developed a Pachinko machine incorporating an autostereoscopic 3D display, and evaluated its effect on the visual function. As of April 2003, the new Pachinko machine has been on sale in Japan. The stereoscopic 3D image is displayed using an LCD. Backlighting for the right and left images is separate, and passes through a polarizing filter before reaching the LCD, which is sandwiched with a micro polarizer. The content selected for display was ukiyoe pictures (Japanese traditional woodblocks). The authors intended to reduce visual fatigue by presenting 3D images with depth "behind" the display and switching between 3D and 2D images. For evaluation of the Pachinko machine, a 2D version with identical content was also prepared, and the effects were examined and compared by testing psycho-physiological responses.
Functional magnetic resonance imaging of divergent and convergent thinking in Big-C creativity.
Japardi, Kevin; Bookheimer, Susan; Knudsen, Kendra; Ghahremani, Dara G; Bilder, Robert M
2018-02-15
The cognitive and physiological processes underlying creativity remain unclear, and very few studies to date have attempted to identify the behavioral and brain characteristics that distinguish exceptional ("Big-C") from everyday ("little-c") creativity. The Big-C Project examined functional brain responses during tasks demanding divergent and convergent thinking in 35 Big-C Visual Artists (VIS), 41 Big-C Scientists (SCI), and 31 individuals in a "smart comparison group" (SCG) matched to the Big-C groups on parental educational attainment and estimated IQ. Functional MRI (fMRI) scans included two activation paradigms widely used in prior creativity research, the Alternate Uses Task (AUT) and Remote Associates Task (RAT), to assess brain function during divergent and convergent thinking, respectively. Task performance did not differ between groups. Functional MRI activation in Big-C and SCG groups differed during the divergent thinking task. No differences in activation were seen during the convergent thinking task. Big-C groups had less activation than SCG in frontal pole, right frontal operculum, left middle frontal gyrus, and bilaterally in occipital cortex. SCI displayed lower frontal and parietal activation relative to the SCG when generating alternate uses in the AUT, while VIS displayed lower frontal activation than SCI and SCG when generating typical qualities (the control condition in the AUT). VIS showed more activation in right inferior frontal gyrus and left supramarginal gyrus relative to SCI. All groups displayed considerable overlapping activation during the RAT. The results confirm substantial overlap in functional activation across groups, but suggest that exceptionally creative individuals may depend less on task-positive networks during tasks that demand divergent thinking. Published by Elsevier Ltd.
Brief Functional Analysis and Intervention Evaluation for Treatment of Saliva-Play
ERIC Educational Resources Information Center
Luiselli, James K.; Ricciardi, Joseph N.; Schmidt, Sarah; Tarr, Melissa
2004-01-01
We conducted a brief (8 days) functional analysis to identify sources of control over persistent saliva-play displayed by a 6-year old child with autism in a school setting. The functional analysis suggested that saliva-play was maintained by automatic reinforcement, leading to an intervention evaluation (3 days) that compared two methods of…
Selection and maturation of antibodies by phage display through fusion to pIX.
Tornetta, Mark; Reddy, Ramachandra; Wheeler, John C
2012-09-01
Antibody discovery and optimization by M13 phage display have evolved significantly over the past twenty years. Multiple methods of antibody display and selection have been developed - direct display on pIII or indirect display through a Cysteine disulfide linkage or a coiled-coil adapter protein. Here we describe display of Fab libraries on the smaller pIX protein at the opposite end of the virion and its application to discovery of novel antibodies from naive libraries. Antibody selection based on pIX-mediated display produces results comparable to other in vitro methods and uses an efficient direct infection of antigen-bound phages, eliminating any chemical dissociation step(s). Additionally, some evidence suggests that pIX-mediated display can be more efficient than pIII-mediated display in affinity selections. Functional assessment of phage-derived antibodies can be hindered by insufficient affinities or lack of epitopic diversity. Here we describe an approach to managing primary hits from our Fab phage libraries into epitope bins and subsequent high-throughput maturation of clones to isolate epitope- and sequence-diverse panels of high affinity binders. Use of the Octet biosensor was done to examine Fab binding in a facile label-free method and determine epitope competition groups. A receptor extracellular domain and chemokine were subjected to this method of binning and affinity maturation. Parental clones demonstrated improvement in affinity from 1-100nM to 10-500pM. Copyright © 2012 Elsevier Inc. All rights reserved.
Polyplanar optical display electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeSanto, L.; Biscardi, C.
The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. The prototype ten inch display is two inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. In order to achieve a long lifetime, the new display uses a 100 milliwatt green solid-state laser (10,000 hr. life) at 532 nm as its light source. To produce real-time video, the laser light is being modulated by amore » Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments. In order to use the solid-state laser as the light source and also fit within the constraints of the B-52 display, the Digital Micromirror Device (DMD{trademark}) circuit board is removed from the Texas Instruments DLP light engine assembly. Due to the compact architecture of the projection system within the display chassis, the DMD{trademark} chip is operated remotely from the Texas Instruments circuit board. The authors discuss the operation of the DMD{trademark} divorced from the light engine and the interfacing of the DMD{trademark} board with various video formats (CVBS, Y/C or S-video and RGB) including the format specific to the B-52 aircraft. A brief discussion of the electronics required to drive the laser is also presented.« less
Optimization of the polyplanar optical display electronics for a monochrome B-52 display
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeSanto, L.
The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. The prototype ten-inch display is two inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. In order to achieve a long lifetime, the new display uses a new 200 mW green solid-state laser (10,000 hr. life) at 532 nm as its light source. To produce real-time video, the laser light is being modulated by amore » Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments (TI). In order to use the solid-state laser as the light source and also fit within the constraints of the B-52 display, the Digital Micromirror Device (DMD{trademark}) chip is operated remotely from the Texas Instruments circuit board. In order to achieve increased brightness a monochrome digitizing interface was investigated. The operation of the DMD{trademark} divorced from the light engine and the interfacing of the DMD{trademark} board with the RS-170 video format specific to the B-52 aircraft will be discussed, including the increased brightness of the monochrome digitizing interface. A brief description of the electronics required to drive the new 200 mW laser is also presented.« less
Transparent 3D display for augmented reality
NASA Astrophysics Data System (ADS)
Lee, Byoungho; Hong, Jisoo
2012-11-01
Two types of transparent three-dimensional display systems applicable for the augmented reality are demonstrated. One of them is a head-mounted-display-type implementation which utilizes the principle of the system adopting the concave floating lens to the virtual mode integral imaging. Such configuration has an advantage in that the threedimensional image can be displayed at sufficiently far distance resolving the accommodation conflict with the real world scene. Incorporating the convex half mirror, which shows a partial transparency, instead of the concave floating lens, makes it possible to implement the transparent three-dimensional display system. The other type is the projection-type implementation, which is more appropriate for the general use than the head-mounted-display-type implementation. Its imaging principle is based on the well-known reflection-type integral imaging. We realize the feature of transparent display by imposing the partial transparency to the array of concave mirror which is used for the screen of reflection-type integral imaging. Two types of configurations, relying on incoherent and coherent light sources, are both possible. For the incoherent configuration, we introduce the concave half mirror array, whereas the coherent one adopts the holographic optical element which replicates the functionality of the lenslet array. Though the projection-type implementation is beneficial than the head-mounted-display in principle, the present status of the technical advance of the spatial light modulator still does not provide the satisfactory visual quality of the displayed three-dimensional image. Hence we expect that the head-mounted-display-type and projection-type implementations will come up in the market in sequence.
NASA Astrophysics Data System (ADS)
Sheraw, Christopher Duncan
2003-10-01
Organic thin film transistors are attractive candidates for a variety of low cost, large area commercial electronics including smart cards, RF identification tags, and flat panel displays. Of particular interest are high performance organic thin film transistors (TFTs) that can be fabricated on flexible polymeric substrates allowing low-cost, lightweight, rugged electronics such as flexible active matrix displays. This thesis reports pentacene organic thin film transistors fabricated on flexible polymeric substrates with record performance, the fastest photolithographically patterned organic TFT integrated circuits on polymeric substrates reported to date, and the fabrication of the organic TFT backplanes used to build the first organic TFT-driven active matrix liquid crystal display (AMLCD), also the first AMLCD on a flexible substrate, ever reported. In addition, the first investigation of functionalized pentacene derivatives used as the active layer in organic thin film transistors is reported. A low temperature (<110°C) process technology was developed allowing the fabrication of high performance organic TFTs, integrated circuits, and large TFT arrays on flexible polymeric substrates. This process includes the development of a novel water-based photolithographic active layer patterning process using polyvinyl alcohol that allows the patterning of organic semiconductor materials for elimination of active layer leakage current without causing device degradation. The small molecule aromatic hydrocarbon pentacene was used as the active layer material to fabricate organic TFTs on the polymeric material polyethylene naphthalate with field-effect mobility as large as 2.1 cm2/V-s and on/off current ratio of 108. These are the best values reported for organic TFTs on polymeric substrates and comparable to organic TFTs on rigid substrates. Analog and digital integrated circuits were also fabricated on polymeric substrates using pentacene TFTs with propagation delay as low as 38 musec and clocked digital circuits that operated at 1.1 kHz. These are the fastest photolithographically patterned organic TFT circuits on polymeric substrates reported to date. Finally, 16 x 16 pentacene TFT pixel arrays were fabricated on polymeric substrates and integrated with polymer dispersed liquid crystal to build an AMLCD. The pixel arrays showed good optical response to changing data signals when standard quarter-VGA display waveforms were applied. This result marks the first organic TFT-driven active matrix liquid crystal display ever reported as well as the first active matrix liquid crystal display on a flexible polymeric substrate. Lastly, functionalized pentacene derivatives were used as the active layer in organic thin film transistor materials. Functional groups were added to the pentacene molecule to influence the molecular ordering so that the amount of pi-orbital overlap would be increased allowing the potential for improved field-effect mobility. The functionalization of these materials also improves solubility allowing for the possibility of solution-processed devices and increased oxidative stability. Organic thin film transistors were fabricated using five different functionalized pentacene active layers. Devices based on the pentacene derivative triisopropylsilyl pentacene were found to have the best performance with field-effect mobility as large as 0.4 cm 2/V-s.
Natural Resource Information System. Volume 1: Overall description
NASA Technical Reports Server (NTRS)
1972-01-01
A prototype computer-based Natural Resource Information System was designed which could store, process, and display data of maximum usefulness to land management decision making. The system includes graphic input and display, the use of remote sensing as a data source, and it is useful at multiple management levels. A survey established current decision making processes and functions, information requirements, and data collection and processing procedures. The applications of remote sensing data and processing requirements were established. Processing software was constructed and a data base established using high-altitude imagery and map coverage of selected areas of SE Arizona. Finally a demonstration of system processing functions was conducted utilizing material from the data base.
Multimission image processing and science data visualization
NASA Technical Reports Server (NTRS)
Green, William B.
1993-01-01
The Operational Science Analysis (OSA) Functional area supports science instrument data display, analysis, visualization and photo processing in support of flight operations of planetary spacecraft managed by the Jet Propulsion Laboratory (JPL). This paper describes the data products generated by the OSA functional area, and the current computer system used to generate these data products. The objectives on a system upgrade now in process are described. The design approach to development of the new system are reviewed, including use of the Unix operating system and X-Window display standards to provide platform independence, portability, and modularity within the new system, is reviewed. The new system should provide a modular and scaleable capability supporting a variety of future missions at JPL.
A ECG Signal Gathering and Displaying System Based on AVR
NASA Astrophysics Data System (ADS)
Ning, Li; Ruilan, Zhang; Jian, Liu; Xiaochen, Wang; Shuying, Chen; Zhuolin, Lang
2017-12-01
This article introduces a kind of system which is based on the AVR to acquire the data of ECG. Such system using the A/D function of ATmega8 chip and the lattice graph LCD to design ECG heart acquisition satisfies the demands above. This design gives a composition of hardware and programming of software about the system in detail which has mainly realized the real-time gathering, the amplifier, the filter, the A/D transformation and the LCD display. Since the AVR includes A/D transformation function and support embedded C language programming, it reduces the peripheral circuit, further more it also decreases the time to design and debug this system.
Incorporating Data Link Messaging into a Multi-function Display for General Aviation Aircraft
NASA Technical Reports Server (NTRS)
Adams, Catherine A.; Murdoch, Jennifer L.
2006-01-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness over conventional instrument flight rules (IFR) procedures.
Design of coin sorter counter based on MCU
NASA Astrophysics Data System (ADS)
Yang, Yahan; Si, Xu
2018-04-01
With unmanned tickets, vending machines promotion, greatly increased the circulation of coins, especially bus companies, the financial sector need to classify a large number of coins every day, inventory, a huge workload. The design of the microcontroller as the control center, combined with the sensor technology and the corresponding mechanical structure to complete the separation of coins and finishing the packaging work and real-time monitoring and display of the type and number of coins function, this article details the system hardware and software design, and The test adjustment shows that the system can achieve the function of separating and sorting coins and monitoring the type and quantity of coins displayed on the coin.
Knowledge of display rules in prelingually deaf and hearing children.
Hosie, J A; Russell, P A; Gray, C D; Scott, C; Hunter, N; Banks, J S; Macaulay, M C
2000-03-01
Deaf children of elementary and secondary school age participated in a study designed to examine their understanding of display rules, the principles governing the expression and concealment of emotion in social situations. The results showed that deaf children's knowledge of display rules, as measured by their reported concealment of emotion, was comparable to that of hearing children of the same age. However, deaf children were less likely to report that they would conceal happiness and anger. They were also less likely to produce reasons for concealing emotion and a smaller proportion of their reasons were prosocial, that is, relating to the feelings of others. The results suggest that the understanding of display rules (which function to protect the feelings of other people) may develop more gradually in deaf children raised in a spoken language environment than it does in hearing children.
Park, Joseph P; Do, Minjae; Jin, Hyo-Eon; Lee, Seung-Wuk; Lee, Haeshin
2014-01-01
M13 bacteriophage (phage) was engineered for the use as a versatile template for preparing various nanostructured materials via genetic engineering coupled to enzymatic chemical conversions. First, we engineered the M13 phage to display TyrGluGluGlu (YEEE) on the pVIII coat protein and then enzymatically converted the Tyr residue to 3,4-dihydroxyl-l-phenylalanine (DOPA). The DOPA-displayed M13 phage could perform two functions: assembly and nucleation. The engineered phage assembles various noble metals, metal oxides, and semiconducting nanoparticles into one-dimensional arrays. Furthermore, the DOPA-displayed phage triggered the nucleation and growth of gold, silver, platinum, bimetallic cobalt-platinum, and bimetallic iron-platinum nanowires. This versatile phage template enables rapid preparation of phage-based prototype devices by eliminating the screening process, thus reducing effort and time.
Seiter, John S; Weger, Harry
2005-04-01
Compared to televised debates using a single-screen format, such debates using a split screen presenting both debaters simultaneously show viewers the nonverbal reactions of each debater's opponent. The authors examined how appropriate or inappropriate such nonverbal behaviors are perceived to be. Students watched one of four versions of a televised debate. One version used a single-screen format, showing only the speaker, whereas the other three versions used a split-screen format in which the speaker's oppodent displayed constant, occasional, or no nonverbal disagreement with the speaker. Students then rated the debaters' appropriateness. Analysis indicated that the opponent was perceived to be less appropriate when he displayed any background disagreement compared to when he did not. The students perceived the speaker as most appropriate when his opponent displayed constant nonverbal disagreement.
Comparison of genetic algorithms with conjugate gradient methods
NASA Technical Reports Server (NTRS)
Bosworth, J. L.; Foo, N. Y.; Zeigler, B. P.
1972-01-01
Genetic algorithms for mathematical function optimization are modeled on search strategies employed in natural adaptation. Comparisons of genetic algorithms with conjugate gradient methods, which were made on an IBM 1800 digital computer, show that genetic algorithms display superior performance over gradient methods for functions which are poorly behaved mathematically, for multimodal functions, and for functions obscured by additive random noise. Genetic methods offer performance comparable to gradient methods for many of the standard functions.
Cognitive deficits and predictors 3 years after diagnosis of a pilocytic astrocytoma in childhood.
Aarsen, Femke K; Paquier, Philippe F; Arts, Willem-Frans; Van Veelen, Marie-Lise; Michiels, Erna; Lequin, Maarten; Catsman-Berrevoets, Coriene E
2009-07-20
PURPOSE To prospectively study cognitive deficits and predictors 3 years after diagnosis in a large series of pediatric patients treated for pilocytic astrocytoma (PA). PATIENTS AND METHODS Sixty-one of 67 children were grouped according to infratentorial, supratentorial midline, and supratentorial hemispheric site. Intelligence, memory, attention, language, visual-spatial, and executive functions were assessed. Included predictors were sex, age, relapse, diagnosis-assessment interval, hydrocephalus, kind of treatment, and tumor variables. Results All children with PA had problems with sustained attention and speed. In the infratentorial group, there also were deficits in verbal intelligence, visual-spatial memory, executive functioning, and naming. Verbal intelligence and verbal memory problems occurred in the brainstem tumor group. The supratentorial hemispheric tumor group had additional problems with selective attention and executive functioning, and the supratentorial midline tumor group displayed no extra impairments. More specifically, the dorsal supratentorial midline tumor group displayed problems with language and verbal memory. Predictors for lower cognitive functioning were hydrocephalus, radiotherapy, residual tumor size, and age; predictors for better functioning were chemotherapy or treatment of hydrocephalus. Almost 60% of children had problems with academic achievement, for which risk factors were relapse and younger age at diagnosis. CONCLUSION Despite normal intelligence at long-term follow-up, children treated for PA display invalidating cognitive impairments. Adequate treatment of hydrocephalus is important for a more favorable long-term cognitive outcome. Even children without initial severe deficits may develop cognitive impairments years after diagnosis, partly because of the phenomenon of growing into deficit, which has devastating implications for academic achievement and quality of life (QOL).
Gautam, Mukesh; Jara, Javier H; Sekerkova, Gabriella; Yasvoina, Marina V; Martina, Marco; Özdinler, P Hande
2016-03-15
Mutations in the ALS2 gene result in early-onset amyotrophic lateral sclerosis, infantile-onset ascending hereditary spastic paraplegia and juvenile primary lateral sclerosis, suggesting prominent upper motor neuron involvement. However, the importance of alsin function for corticospinal motor neuron (CSMN) health and stability remains unknown. To date, four separate alsin knockout (Alsin(KO)) mouse models have been generated, and despite hopes of mimicking human pathology, none displayed profound motor function defects. This, however, does not rule out the possibility of neuronal defects within CSMN, which is not easy to detect in these mice. Detailed cellular analysis of CSMN has been hampered due to their limited numbers and the complex and heterogeneous structure of the cerebral cortex. In an effort to visualize CSMN in vivo and to investigate precise aspects of neuronal abnormalities in the absence of alsin function, we generated Alsin(KO)-UeGFP mice, by crossing Alsin(KO) and UCHL1-eGFP mice, a CSMN reporter line. We find that CSMN display vacuolated apical dendrites with increased autophagy, shrinkage of soma size and axonal pathology even in the pons region. Immunocytochemistry coupled with electron microscopy reveal that alsin is important for maintaining cellular cytoarchitecture and integrity of cellular organelles. In its absence, CSMN displays selective defects both in mitochondria and Golgi apparatus. UCHL1-eGFP mice help understand the underlying cellular factors that lead to CSMN vulnerability in diseases, and our findings reveal unique importance of alsin function for CSMN health and stability. © The Author 2016. Published by Oxford University Press.
Mazzarelli, Joan M; Brestelli, John; Gorski, Regina K; Liu, Junmin; Manduchi, Elisabetta; Pinney, Deborah F; Schug, Jonathan; White, Peter; Kaestner, Klaus H; Stoeckert, Christian J
2007-01-01
EPConDB (http://www.cbil.upenn.edu/EPConDB) is a public web site that supports research in diabetes, pancreatic development and beta-cell function by providing information about genes expressed in cells of the pancreas. EPConDB displays expression profiles for individual genes and information about transcripts, promoter elements and transcription factor binding sites. Gene expression results are obtained from studies examining tissue expression, pancreatic development and growth, differentiation of insulin-producing cells, islet or beta-cell injury, and genetic models of impaired beta-cell function. The expression datasets are derived using different microarray platforms, including the BCBC PancChips and Affymetrix gene expression arrays. Other datasets include semi-quantitative RT-PCR and MPSS expression studies. For selected microarray studies, lists of differentially expressed genes, derived from PaGE analysis, are displayed on the site. EPConDB provides database queries and tools to examine the relationship between a gene, its transcriptional regulation, protein function and expression in pancreatic tissues.
Interpersonal distance regulates functional grouping tendencies of agents in team sports.
Passos, Pedro; Milho, João; Fonseca, Sofia; Borges, João; Araújo, Duarte; Davids, Keith
2011-01-01
The authors examined whether, similar to collective agent behaviors in complex, biological systems (e.g., schools of fish and colonies of ants), performers in team sports displayed functional coordination tendencies, based on local interaction rules during performance. To investigate this issue, they used videogrammetry and digitizing procedures to observe interpersonal interactions in common 4 versus 2 + 2 subphases of the team sport of rugby union, involving 16 participants aged between 16 and 17 years of age. They observed pattern-forming dynamics in attacking subunits (n = 4 players) attempting to penetrate 2 defensive lines (n = 2 players in each). Data showed that within each attacking subunit, the 4 players displayed emergent functional grouping tendencies that differed between the 2 defensive lines. Results confirmed that grouping tendencies in attacking subunits of team games are sensitive to different task constraints, such as relative positioning to nearest defenders. It was concluded that running correlations were particularly useful for measuring the level of interpersonal coordination in functional grouping tendencies within attacking subunits.
Topological Landscapes: A Terrain Metaphor for ScientificData
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, Gunther H.; Bremer, Peer-Timo; Pascucci, Valerio
2007-08-01
Scientific visualization and illustration tools are designed to help people understand the structure and complexity of scientific data with images that are as informative and intuitive as possible. In this context, the use of metaphors plays an important role, since they make complex information easily accessible by using commonly known concepts. In this paper we propose a new metaphor, called 'Topological Landscapes', which facilitates understanding the topological structure of scalar functions. The basic idea is to construct a terrain with the same topology as a given dataset and to display the terrain as an easily understood representation of the actualmore » input data. In this projection from an n-dimensional scalar function to a two-dimensional (2D) model we preserve function values of critical points, the persistence (function span) of topological features, and one possible additional metric property (in our examples volume). By displaying this topologically equivalent landscape together with the original data we harness the natural human proficiency in understanding terrain topography and make complex topological information easily accessible.« less
Development of exosome surface display technology in living human cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stickney, Zachary, E-mail: zstickney@scu.edu; Losacco, Joseph, E-mail: jlosacco@scu.edu; McDevitt, Sophie, E-mail: smmcdevitt@scu.edu
Surface display technology is an emerging key player in presenting functional proteins for targeted drug delivery and therapy. Although a number of technologies exist, a desirable mammalian surface display system is lacking. Exosomes are extracellular vesicles that facilitate cell–cell communication and can be engineered as nano-shuttles for cell-specific delivery. In this study, we report the development of a novel exosome surface display technology by exploiting mammalian cell secreted nano-vesicles and their trans-membrane protein tetraspanins. By constructing a set of fluorescent reporters for both the inner and outer surface display on exosomes at two selected sites of tetraspanins, we demonstrated themore » successful exosomal display via gene transfection and monitoring fluorescence in vivo. We subsequently validated our system by demonstrating the expected intracellular partitioning of reporter protein into sub-cellular compartments and secretion of exosomes from human HEK293 cells. Lastly, we established the stable engineered cells to harness the ability of this robust system for continuous production, secretion, and uptake of displayed exosomes with minimal impact on human cell biology. In sum, our work paved the way for potential applications of exosome, including exosome tracking and imaging, targeted drug delivery, as well as exosome-mediated vaccine and therapy.« less
NASA Technical Reports Server (NTRS)
Decker, William A.; Bray, Richard S.; Simmons, Rickey C.; Tucker, George E.
1993-01-01
A piloted simulation experiment was conducted using the NASA Ames Research Center Vertical Motion Simulator to evaluate two cockpit display formats designed for manual control on steep instrument approaches for a civil transport tiltrotor aircraft. The first display included a four-cue (pitch, roll, power lever position, and nacelle angle movement prompt) flight director. The second display format provided instantaneous flight path angle information together with other symbols for terminal area guidance. Pilots evaluated these display formats for an instrument approach task which required a level flight conversion from airplane-mode flight to helicopter-mode flight while decelerating to the nominal approach airspeed. Pilots tracked glide slopes of 6, 9, 15 and 25 degrees, terminating in a hover for a vertical landing on a 150 feet square vertipad. Approaches were conducted with low visibility and ceilings and with crosswinds and turbulence, with all aircraft systems functioning normally and were carried through to a landing. Desired approach and tracking performance was achieved with generally satisfactory handling qualities using either display format on glide slopes up through 15 degrees. Evaluations with both display formats for a 25 degree glide slope revealed serious problems with glide slope tracking at low airspeeds in crosswinds and the loss of the intended landing spot from the cockpit field of view.
Wilkinson, Krista M; Dennis, Nancy A; Webb, Christina E; Therrien, Mari; Stradtman, Megan; Farmer, Jacquelyn; Leach, Raevynn; Warrenfeltz, Megan; Zeuner, Courtney
2015-01-01
Visual aided augmentative and alternative communication (AAC) consists of books or technologies that contain visual symbols to supplement spoken language. A common observation concerning some forms of aided AAC is that message preparation can be frustratingly slow. We explored the uses of fMRI to examine the neural correlates of visual search for line drawings on AAC displays in 18 college students under two experimental conditions. Under one condition, the location of the icons remained stable and participants were able to learn the spatial layout of the display. Under the other condition, constant shuffling of the locations of the icons prevented participants from learning the layout, impeding rapid search. Brain activation was contrasted under these conditions. Rapid search in the stable display was associated with greater activation of cortical and subcortical regions associated with memory, motor learning, and dorsal visual pathways compared to the search in the unpredictable display. Rapid search for line drawings on stable AAC displays involves not just the conceptual knowledge of the symbol meaning but also the integration of motor, memory, and visual-spatial knowledge about the display layout. Further research must study individuals who use AAC, as well as the functional effect of interventions that promote knowledge about array layout.
Cognition and Resting-State Functional Connectivity in Schizophrenia
Sheffield, Julia M; Barch, Deanna M
2015-01-01
Individuals with schizophrenia consistently display deficits in a multitude of cognitive domains, but the neurobiological source of these cognitive impairments remains unclear. By analyzing the functional connectivity of resting-state functional magnetic resonance imaging (rs-fcMRI) data in clinical populations like schizophrenia, research groups have begun elucidating abnormalities in the intrinsic communication between specific brain regions, and assessing relationships between these abnormalities and cognitive performance in schizophrenia. Here we review studies that have reported analysis of these brain-behavior relationships. Through this systematic review we found that patients with schizophrenia display abnormalities within and between regions comprising 1) the cortico-cerebellar-striatal-thalamic loop and 2) task-positive and task-negative cortical networks. Importantly, we did not observe unique relationships between specific functional connectivity abnormalities and distinct cognitive domains, suggesting that the observed functional systems may underlie mechanisms that are shared across cognitive abilities, the disturbance of which could contribute to the “generalized” cognitive deficit found in schizophrenia. We also note several areas of methodological change that we believe will strengthen this literature. PMID:26698018
Interactive digital image manipulation system
NASA Technical Reports Server (NTRS)
Henze, J.; Dezur, R.
1975-01-01
The system is designed for manipulation, analysis, interpretation, and processing of a wide variety of image data. LANDSAT (ERTS) and other data in digital form can be input directly into the system. Photographic prints and transparencies are first converted to digital form with an on-line high-resolution microdensitometer. The system is implemented on a Hewlett-Packard 3000 computer with 128 K bytes of core memory and a 47.5 megabyte disk. It includes a true color display monitor, with processing memories, graphics overlays, and a movable cursor. Image data formats are flexible so that there is no restriction to a given set of remote sensors. Conversion between data types is available to provide a basis for comparison of the various data. Multispectral data is fully supported, and there is no restriction on the number of dimensions. In this way multispectral data collected at more than one point in time may simply be treated as a data collected with twice (three times, etc.) the number of sensors. There are various libraries of functions available to the user: processing functions, display functions, system functions, and earth resources applications functions.
Xu, Xuxu; Gao, Yan; Zhai, Zhiyong; Zhang, Shuo; Shan, Fengping; Feng, Juan
2016-01-01
ABSTRACT Repulsive guidance molecule a (RGMa) is an axonal guidance molecule that has recently found to exert function in immune system. This study evaluated the function of RGMa in modulation of dendritic cells (DCs) function stimulated with Achyranthes bidentata polysaccharide (ABP) and lipopolysaccharide (LPS) using a RGMa-neutralizing antibody. Compared with the Control-IgG/ABP and Control-IgG/LPS groups, DCs in the Anti-RGMa/ABP and Anti-RGMa/LPS groups 1) showed small, round cells with a few cell processes and organelles, and many pinocytotic vesicles; 2) had decreased MHC II, CD86, CD80, and CD40 expression; 3) displayed the decreased IL-12p70, IL-1β and TNF-α levels and increased IL-10 secretion; 4) had a high percentage of FITC-dextran uptake; and 5) displayed a reduced ability to drive T cell proliferation and reinforced T cell polarization toward a Th2 cytokine pattern. We conclude that DCs treated with RGMa-neutralizing antibodies present with tolerogenic and immunoregulatory characteristics, which provides new insights into further understanding of the function of RGMa. PMID:26986456
Xu, Xuxu; Gao, Yan; Zhai, Zhiyong; Zhang, Shuo; Shan, Fengping; Feng, Juan
2016-08-02
Repulsive guidance molecule a (RGMa) is an axonal guidance molecule that has recently found to exert function in immune system. This study evaluated the function of RGMa in modulation of dendritic cells (DCs) function stimulated with Achyranthes bidentata polysaccharide (ABP) and lipopolysaccharide (LPS) using a RGMa-neutralizing antibody. Compared with the Control-IgG/ABP and Control-IgG/LPS groups, DCs in the Anti-RGMa/ABP and Anti-RGMa/LPS groups 1) showed small, round cells with a few cell processes and organelles, and many pinocytotic vesicles; 2) had decreased MHC II, CD86, CD80, and CD40 expression; 3) displayed the decreased IL-12p70, IL-1β and TNF-α levels and increased IL-10 secretion; 4) had a high percentage of FITC-dextran uptake; and 5) displayed a reduced ability to drive T cell proliferation and reinforced T cell polarization toward a Th2 cytokine pattern. We conclude that DCs treated with RGMa-neutralizing antibodies present with tolerogenic and immunoregulatory characteristics, which provides new insights into further understanding of the function of RGMa.
IMAGEP - A FORTRAN ALGORITHM FOR DIGITAL IMAGE PROCESSING
NASA Technical Reports Server (NTRS)
Roth, D. J.
1994-01-01
IMAGEP is a FORTRAN computer algorithm containing various image processing, analysis, and enhancement functions. It is a keyboard-driven program organized into nine subroutines. Within the subroutines are other routines, also, selected via keyboard. Some of the functions performed by IMAGEP include digitization, storage and retrieval of images; image enhancement by contrast expansion, addition and subtraction, magnification, inversion, and bit shifting; display and movement of cursor; display of grey level histogram of image; and display of the variation of grey level intensity as a function of image position. This algorithm has possible scientific, industrial, and biomedical applications in material flaw studies, steel and ore analysis, and pathology, respectively. IMAGEP is written in VAX FORTRAN for DEC VAX series computers running VMS. The program requires the use of a Grinnell 274 image processor which can be obtained from Mark McCloud Associates, Campbell, CA. An object library of the required GMR series software is included on the distribution media. IMAGEP requires 1Mb of RAM for execution. The standard distribution medium for this program is a 1600 BPI 9track magnetic tape in VAX FILES-11 format. It is also available on a TK50 tape cartridge in VAX FILES-11 format. This program was developed in 1991. DEC, VAX, VMS, and TK50 are trademarks of Digital Equipment Corporation.
Albrecht, Bjoern; Brandeis, Daniel; Uebel, Henrik; Heinrich, Hartmut; Mueller, Ueli C.; Hasselhorn, Marcus; Steinhausen, Hans-Christoph; Rothenberger, Aribert; Banaschewski, Tobias
2008-01-01
Background Attention deficit/hyperactivity disorder is a very common and highly heritable child psychiatric disorder associated with dysfunctions in fronto-striatal networks that control attention and response organisation. Aim of this study was to investigate whether features of action monitoring related to dopaminergic functions represent endophenotypes which are brain functions on the pathway from genes and environmental risk factors to behaviour. Methods Action monitoring and error processing as indicated by behavioural and electrophysiological parameters during a flanker task were examined in boys with ADHD combined type according to DSM-IV (N=68), their nonaffected siblings (N=18) and healthy controls with no known family history of ADHD (N=22). Results Boys with ADHD displayed slower and more variable reaction-times. Error negativity (Ne) was smaller in boys with ADHD compared to healthy controls, while nonaffected siblings displayed intermediate amplitudes following a linear model predicted by genetic concordance. The three groups did not differ on error positivity (Pe). N2 amplitude enhancement due to conflict (incongruent flankers) was reduced in the ADHD group. Nonaffected siblings also displayed intermediate N2 enhancement. Conclusions Converging evidence from behavioural and ERP findings suggests that action monitoring and initial error processing, both related to dopaminergically modulated functions of anterior cingulate cortex, might be an endophenotype related to ADHD. PMID:18339358
Initial experience with a nuclear medicine viewing workstation
NASA Astrophysics Data System (ADS)
Witt, Robert M.; Burt, Robert W.
1992-07-01
Graphical User Interfaced (GUI) workstations are now available from commercial vendors. We recently installed a GUI workstation in our nuclear medicine reading room for exclusive use of staff and resident physicians. The system is built upon a Macintosh platform and has been available as a DELTAmanager from MedImage and more recently as an ICON V from Siemens Medical Systems. The workstation provides only display functions and connects to our existing nuclear medicine imaging system via ethernet. The system has some processing capabilities to create oblique, sagittal and coronal views from transverse tomographic views. Hard copy output is via a screen save device and a thermal color printer. The DELTAmanager replaced a MicroDELTA workstation which had both process and view functions. The mouse activated GUI has made remarkable changes to physicians'' use of the nuclear medicine viewing system. Training time to view and review studies has been reduced from hours to about 30-minutes. Generation of oblique views and display of brain and heart tomographic studies has been reduced from about 30-minutes of technician''s time to about 5-minutes of physician''s time. Overall operator functionality has been increased so that resident physicians with little prior computer experience can access all images on the image server and display pertinent patient images when consulting with other staff.
ERIC Educational Resources Information Center
Watkins, Nicholas; Rapp, John T.
2013-01-01
Only a few studies have compared the convergent validity of the Questions About Behavioral Function (QABF) scale to the results of functional analyses (FA). In the current study, six participants who emitted problem behaviors participated in either a brief, or a no-interaction-series FA, while each participant's parent completed the QABF. The…
Comparison of Specifications for Head-Up Displays in the Navy A-4M, A- 7E, AV-8A, and F-14A Aircraft
1979-11-05
nomenclature and function for the A-7E aircraft (0). Modes of Opersti&n "rhe A-7i hsa ton mod a of opetition . The display formats for each mods are...tselactad TACAI radial. STP- Povildes course to selclWl preset dasti- ation point. AWL/? CO - Provides gilideo•e Information duriLng landing or preclslon
Performance considerations for high-definition head-mounted displays
NASA Technical Reports Server (NTRS)
Edwards, Oliver J.; Larimer, James; Gille, Jennifer
1992-01-01
Design image-optimization for helmet-mounted displays (HMDs) for military systems is presently discussed within the framework of a systems-engineering approach that encompasses (1) a description of natural targets in the field; (2) the characteristics of human visual perception; and (3) device specifications that directly relate to these ecological and human-factors parameters. Attention is given to target size and contrast and the relationship of the modulation transfer function to image resolution.
Adams, Bryn L; Finch, Amethist S; Hurley, Margaret M; Sarkes, Deborah A; Stratis-Cullum, Dimitra N
2013-09-06
The first-ever peptide biomaterial discovery using an unconstrained engineered bacterial display technology is reported. Using this approach, we have developed genetically engineered peptide binders for a bulk aluminum alloy and use molecular dynamics simulation of peptide conformational fluctuations to demonstrate sequence-dependent, structure-function relationships for metal and metal oxide interactions. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hazra, Rasmani; Jimenez, Mark; Desai, Reena; Handelsman, David J; Allan, Charles M
2013-09-01
We recently created a mouse model displaying precocious Sertoli cell (SC) and spermatogenic development induced by SC-specific transgenic androgen receptor expression (TgSCAR). Here we reveal that TgSCAR regulates the development, function, and absolute number of Leydig cells (LCs). Total fetal and adult type LC numbers were reduced in postnatal and adult TgSCAR vs control testes, despite normal circulating LH levels. Normal LC to SC ratios found in TgSCAR testes indicate that SC androgen receptor (SCAR)-mediated activity confers a quorum-dependent relationship between total SC and LC numbers. TgSCAR enhanced LC differentiation, shown by elevated ratios of advanced to immature LC types, and reduced LC proliferation in postnatal TgSCAR vs control testes. Postnatal TgSCAR testes displayed up-regulated expression of coupled ligand-receptor transcripts (Amh-Amhr2, Dhh-Ptch1, Pdgfa-Pdgfra) for potential SCAR-stimulated paracrine pathways, which may coordinate LC differentiation. Neonatal TgSCAR testes displayed normal T and dihydrotestosterone levels despite differential changes to steroidogenic gene expression, with down-regulated Star, Cyp11a1, and Cyp17a1 expression contrasting with up-regulated Hsd3b1, Hsd17b3, and Srd5a1 expression. TgSCAR males also displayed elevated postnatal and normal adult serum testosterone levels, despite reduced LC numbers. Enhanced adult-type LC steroidogenic output was revealed by increased pubertal testicular T, dihydrotestosterone, 3α-diol and 3β-diol levels per LC and up-regulated steroidogenic gene (Nr5a1, Lhr, Cyp11a1, Cyp17a1, Hsd3b6, Srd5a1) expression in pubertal or adult TgSCAR vs control males, suggesting regulatory mechanisms maintain androgen levels independently of absolute LC numbers. Our unique gain-of-function TgSCAR model has revealed that SCAR activity controls temporal LC differentiation, steroidogenic function, and population size.
Kotani, Shohei; Izawa, Sho; Komai, Noriyuki; Takayanagi, Ayumi; Arioka, Manabu
2016-11-01
In mammals, cytosolic phospholipases A 2 (cPLA 2 s) play important physiological roles by releasing arachidonic acid, a precursor for bioactive lipid mediators, from the biological membranes. In contrast, fungal cPLA 2 -like proteins are much less characterized and their roles have remained elusive. AoPlaA is a cPLA 2 -like protein in the filamentous fungus Aspergillus oryzae which, unlike mammalian cPLA 2 , localizes to mitochondria. In this study, we investigated the biochemical and physiological functions of AoPlaA. Recombinant AoPlaA produced in E. coli displayed Ca 2+ -independent lipolytic activity. Mass spectrometry analysis demonstrated that AoPlaA displayed PLA 2 activity to phosphatidylethanolamine (PE), but not to other phospholipids, and generated 1-acylated lysoPE. Catalytic site mutants of AoPlaA displayed almost no or largely reduced activity to PE. Consistent with PE-specific activity of AoPlaA, AoplaA-overexpressing strain showed decreased PE content in the mitochondrial fraction. In contrast, AoplaA-disruption strain displayed increased content of cardiolipin. AoplaA-overexpressing strain, but not its counterparts overexpressing the catalytic site mutants, exhibited retarded growth at low temperature, possibly because of the impairment of the mitochondrial function caused by excess degradation of PE. These results suggest that AoPlaA is a novel PE-specific PLA 2 that plays a regulatory role in the maintenance of mitochondrial phospholipid composition. Copyright © 2016 Elsevier Inc. All rights reserved.
Somatostatin displayed on filamentous phage as a receptor-specific agonist
Rousch, Mat; Lutgerink, Jan T; Coote, James; de Bruïne, Adriaan; Arends, Jan-Willem; Hoogenboom, Hennie R
1998-01-01
In search of methods to identify bio-active ligands specific for G protein-coupled receptors with seven transmembrane spanning regions, we have developed a filamentous phage-based selection and functional screening method. First, methods for panning peptide phage on cells were established, using the hormone somatostatin as a model. Somatostatin was displayed on the surface of filamentous phage by cloning into phage(mid) vectors and fusion to either pIII or pVIII viral coat proteins. Peptide displaying phage bound to a polyclonal anti-somatostatin serum, and, more importantly, to several somatostatin receptor subtypes (Sst) expressed on transfected CHO-K1 cells, in a pattern which was dependent on the used display method. Binding was competed with somatostatin, with an IC50 in the nanomolar range. The phage were specifically enriched by panning on cells, establishing conditions for cell selections of phage libraries. Binding of somatostatin displaying phage to sst2 on a reporter cell line, in which binding of natural ligand reduces secretion of alkaline phosphatase (via a cyclic AMP responsive element sensitive promoter), proved that the phage particles act as receptor-specific agonists. Less than 100 phage particles per cell were required for this activity, which is approximately 1000 fold less than soluble somatostatin, suggesting that phage binding interferes with normal receptor desensitization and/or recycling. The combination of biopanning of phage libraries on cells with functional screening of phage particles for receptor triggering activity, may be used to select novel, bio-active ligands from phage libraries of random peptides, antibody fragments, or libraries based on the natural receptor ligand. PMID:9776337
Design and Development of Functionally Operative and Visually Appealing Remote Firing Room Displays
NASA Technical Reports Server (NTRS)
Quaranto, Kristy
2014-01-01
This internship provided an opportunity for an intern to work with NASA's Ground Support Equipment (GSE) for the Spaceport Command and Control System (SCCS) at Kennedy Space Center as a remote display developer, under NASA mentor Kurt Leucht. The main focus was on creating remote displays for the hypergolic and high pressure helium subsystem team to help control the filling of the respective tanks. As a remote display developer for the GSE hypergolic and high pressure helium subsystem team the intern was responsible for creating and testing graphical remote displays to be used in the Launch Control Center (LCC) on the Firing Room's computer monitors. To become more familiar with the subsystem, the individual attended multiple project meetings and acquired their specific requirements regarding what needed to be included in the remote displays. After receiving the requirements, the next step was to create a display that had both visual appeal and logical order using the Display Editor, on the Virtual Machine (VM). In doing so, all Compact Unique Identifiers (CUI), which are associated with specific components within the subsystem, will need to be included in each respective display for the system to run properly. Then, once the display was created it needed to be tested to ensure that the display runs as intended by using the Test Driver, also found on the VM. This Test Driver is a specific application that checks to make sure all the CUIs in the display are running properly and returning the correct form of information. After creating and locally testing the display it will need to go through further testing and evaluation before deemed suitable for actual use. By the end of the semester long experience at NASA's Kennedy Space Center, the individual should have gained great knowledge and experience in various areas of display development and testing. They were able to demonstrate this new knowledge obtained by creating multiple successful remote displays that will one day be used by the hypergolic and high pressure helium subsystem team in one of the LCC's firing rooms to fill the new Orion spacecraft.
A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
Park, Kyeonghwan; Kim, Seung Mok; Eom, Won-Jin; Kim, Jae Joon
2017-01-01
This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC) for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor interfaces are incorporated. The reconfigurable feature is effectively implemented by proposing two basis readout topologies of amplifier-based and oscillator-based circuits. For noise-immune design against various noises from inherent human-touch operations, an alternate-sampling error-correction scheme is proposed and integrated inside the ROIC, achieving a 12-bit resolution of successive approximation register (SAR) of analog-to-digital conversion without additional calibrations. A ROIC prototype that includes the whole proposed functions and data converters was fabricated in a 0.18 μm complementary metal oxide semiconductor (CMOS) process, and its feasibility was experimentally verified to support multiple heterogeneous sensing functions of touch, electrocardiogram, body impedance, and environmental sensors. PMID:28368355
A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems.
Park, Kyeonghwan; Kim, Seung Mok; Eom, Won-Jin; Kim, Jae Joon
2017-04-03
This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC) for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor interfaces are incorporated. The reconfigurable feature is effectively implemented by proposing two basis readout topologies of amplifier-based and oscillator-based circuits. For noise-immune design against various noises from inherent human-touch operations, an alternate-sampling error-correction scheme is proposed and integrated inside the ROIC, achieving a 12-bit resolution of successive approximation register (SAR) of analog-to-digital conversion without additional calibrations. A ROIC prototype that includes the whole proposed functions and data converters was fabricated in a 0.18 μm complementary metal oxide semiconductor (CMOS) process, and its feasibility was experimentally verified to support multiple heterogeneous sensing functions of touch, electrocardiogram, body impedance, and environmental sensors.
Viewing the functional consequences of traumatic brain injury by using brain SPECT.
Pavel, D; Jobe, T; Devore-Best, S; Davis, G; Epstein, P; Sinha, S; Kohn, R; Craita, I; Liu, P; Chang, Y
2006-03-01
High-resolution brain SPECT is increasingly benefiting from improved image processing software and multiple complementary display capabilities. This enables detailed functional mapping of the disturbances in relative perfusion occurring after TBI. The patient population consisted of 26 cases (ages 8-61 years)between 3 months and 6 years after traumatic brain injury.A very strong case can be made for the routine use of Brain SPECT in TBI. Indeed it can provide a detailed evaluation of multiple functional consequences after TBI and is thus capable of supplementing the clinical evaluation and tailoring the therapeutic strategies needed. In so doing it also provides significant additional information beyond that available from MRI/CT. The critical factor for Brain SPECT's clinical relevance is a carefully designed technical protocol, including displays which should enable a comprehensive description of the patterns found, in a user friendly mode.
Swainsbury, David J K; Scheidelaar, Stefan; van Grondelle, Rienk; Killian, J Antoinette; Jones, Michael R
2014-01-01
Integral membrane proteins often present daunting challenges for biophysical characterization, a fundamental issue being how to select a surfactant that will optimally preserve the individual structure and functional properties of a given membrane protein. Bacterial reaction centers offer a rare opportunity to compare the properties of an integral membrane protein in different artificial lipid/surfactant environments with those in the native bilayer. Here, we demonstrate that reaction centers purified using a styrene maleic acid copolymer remain associated with a complement of native lipids and do not display the modified functional properties that typically result from detergent solubilization. Direct comparisons show that reaction centers are more stable in this copolymer/lipid environment than in a detergent micelle or even in the native membrane, suggesting a promising new route to exploitation of such photovoltaic integral membrane proteins in device applications. PMID:25212490
Temporal correlation functions of concentration fluctuations: an anomalous case.
Lubelski, Ariel; Klafter, Joseph
2008-10-09
We calculate, within the framework of the continuous time random walk (CTRW) model, multiparticle temporal correlation functions of concentration fluctuations (CCF) in systems that display anomalous subdiffusion. The subdiffusion stems from the nonstationary nature of the CTRW waiting times, which also lead to aging and ergodicity breaking. Due to aging, a system of diffusing particles tends to slow down as time progresses, and therefore, the temporal correlation functions strongly depend on the initial time of measurement. As a consequence, time averages of the CCF differ from ensemble averages, displaying therefore ergodicity breaking. We provide a simple example that demonstrates the difference between these two averages, a difference that might be amenable to experimental tests. We focus on the case of ensemble averaging and assume that the preparation time of the system coincides with the starting time of the measurement. Our analytical calculations are supported by computer simulations based on the CTRW model.
Kutsuna, Kenichiro; Matsuura, Yasuyuki; Fujikake, Kazuhiro; Miyao, Masaru; Takada, Hiroki
2013-01-01
Visually induced motion sickness (VIMS) is caused by sensory conflict, the disagreement between vergence and visual accommodation while observing stereoscopic images. VIMS can be measured by psychological and physiological methods. We propose a mathematical methodology to measure the effect of three-dimensional (3D) images on the equilibrium function. In this study, body sway in the resting state is compared with that during exposure to 3D video clips on a liquid crystal display (LCD) and on a head mounted display (HMD). In addition, the Simulator Sickness Questionnaire (SSQ) was completed immediately afterward. Based on the statistical analysis of the SSQ subscores and each index for stabilograms, we succeeded in determining the quantity of the VIMS during exposure to the stereoscopic images. Moreover, we discuss the metamorphism in the potential functions to control the standing posture during the exposure to stereoscopic video clips.
Space shuttle configuration accounting functional design specification
NASA Technical Reports Server (NTRS)
1974-01-01
An analysis is presented of the requirements for an on-line automated system which must be capable of tracking the status of requirements and engineering changes and of providing accurate and timely records. The functional design specification provides the definition, description, and character length of the required data elements and the interrelationship of data elements to adequately track, display, and report the status of active configuration changes. As changes to the space shuttle program levels II and III configuration are proposed, evaluated, and dispositioned, it is the function of the configuration management office to maintain records regarding changes to the baseline and to track and report the status of those changes. The configuration accounting system will consist of a combination of computers, computer terminals, software, and procedures, all of which are designed to store, retrieve, display, and process information required to track proposed and proved engineering changes to maintain baseline documentation of the space shuttle program levels II and III.
Weatherly, Jeffrey N; Plumm, Karyn M
2012-01-01
Delay discounting occurs when the subjective value of an outcome decreases because its delivery is delayed. Previous research has suggested that the rate at which some, but not all, outcomes are discounted varies as a function of regular church attendance. In the present study, 509 participants completed measures of intrinsic religiousness, extrinsic religiousness, religious fundamentalism, and whether they regularly attended church services. They then completed a delay-discounting task involving five outcomes. Although religiousness was not a significant predictor of discounting for all outcomes, participants scoring high in intrinsic religiousness tended to display less delay discounting than participants scoring low. Likewise, participants scoring high in religious fundamentalism tended to display more delay discounting than participants scoring low. These results partially replicate previous ones in showing that the process of discounting may vary as a function of religiousness. The results also provide some direction for those interested in altering how individuals discount.
Cognitive performance in women with fibromyalgia: A case-control study.
Pérez de Heredia-Torres, Marta; Huertas-Hoyas, Elisabet; Máximo-Bocanegra, Nuria; Palacios-Ceña, Domingo; Fernández-De-Las-Peñas, César
2016-10-01
This study aimed to evaluate the differences in cognitive skills between women with fibromyalgia and healthy women, and the correlations between functional independence and cognitive limitations. A cross-sectional study was performed. Twenty women with fibromyalgia and 20 matched controls participated. Outcomes included the Numerical Pain Rating Scale, the Functional Independence Measure, the Fibromyalgia Impact Questionnaire and Gradior © software. The Student's t-test and the Spearman's rho test were applied to the data. Women affected required a greater mean time (P < 0.020) and maximum time (P < 0.015) during the attention test than the healthy controls. In the memory test they displayed greater execution errors (P < 0.001), minimal time (P < 0.001) and mean time (P < 0.001) whereas, in the perception tests, they displayed a greater mean time (P < 0.009) and maximum time (P < 0.048). Correlations were found between the domains of the functional independence measure and the cognitive abilities assessed. Women with fibromyalgia exhibited a decreased cognitive ability compared to healthy controls, which negatively affected the performance of daily activities, such as upper limb dressing, feeding and personal hygiene. Patients required more time to perform activities requiring both attention and perception, decreasing their functional independence. Also, they displayed greater errors when performing activities requiring the use of memory. Occupational therapists treating women with fibromyalgia should consider the negative impact of possible cognitive deficits on the performance of daily activities and offer targeted support strategies. © 2016 Occupational Therapy Australia.
Chen, Xianzhong
2017-03-04
The cell surface serves as a functional interface between the inside and the outside of the cell. Within the past 20 y the ability of yeast (Saccharomyces cerevisiae) to display heterologous proteins on the cell surface has been demonstrated. Furthermore, S. cerevisiae has been both developed and applied in expression of various proteins on the cell surface. Using this novel and useful strategy, proteins and peptides of various kinds can be displayed on the yeast cell surface by fusing the protein of interest with the glycosylphosphatidylinositol (GPI)-anchoring system. Consolidated bioprocessing (CBP) using S. cerevisiae represents a promising technology for bioethanol production. However, further work is needed to improve the fermentation performance. There is some excellent previous research regarding construction of yeast biocatalyst using the surface display system to decrease cost, increase efficiency of ethanol production and directly utilize starch or biomass for fuel production. In this commentary, we reviewed the yeast surface display system and highlighted recent work. Additionally, the strategy for decrease of phytate phosphate content in dried distillers grains with solubles (DDGS) by display of phytase on the yeast cell surface is discussed.
Virtual network computing: cross-platform remote display and collaboration software.
Konerding, D E
1999-04-01
VNC (Virtual Network Computing) is a computer program written to address the problem of cross-platform remote desktop/application display. VNC uses a client/server model in which an image of the desktop of the server is transmitted to the client and displayed. The client collects mouse and keyboard input from the user and transmits them back to the server. The VNC client and server can run on Windows 95/98/NT, MacOS, and Unix (including Linux) operating systems. VNC is multi-user on Unix machines (any number of servers can be run are unrelated to the primary display of the computer), while it is effectively single-user on Macintosh and Windows machines (only one server can be run, displaying the contents of the primary display of the server). The VNC servers can be configured to allow more than one client to connect at one time, effectively allowing collaboration through the shared desktop. I describe the function of VNC, provide details of installation, describe how it achieves its goal, and evaluate the use of VNC for molecular modelling. VNC is an extremely useful tool for collaboration, instruction, software development, and debugging of graphical programs with remote users.
Validation of Minimum Display Requirements for a UAS Detect and Avoid System
NASA Technical Reports Server (NTRS)
Rorie, Conrad; Fern, Lisa; Roberts, Zach; Monk, Kevin; Santiago, Confesor; Shively, Jay
2017-01-01
The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to see and avoid other aircraft in order to maintain well clear. The present study is the final in a series of human-in-the-loop experiments designed to explore and test the various display and alerting requirements being incorporated into the minimum operational performance standards (MOPS) for a UAS-specific detect and avoid system that would replace the see and avoid function required of manned aircraft. Two display configurations were tested - an integrated display and a standalone display - and their impact on pilot response times and ability to maintain DAA well clear were compared. Results indicated that the current draft of the MOPS result in high-level performance and did not meaningfully differ by display configuration.
Visual effects in great bowerbird sexual displays and their implications for signal design
Endler, John A.; Gaburro, Julie; Kelley, Laura A.
2014-01-01
It is often assumed that the primary purpose of a male's sexual display is to provide information about quality, or to strongly stimulate prospective mates, but other functions of courtship displays have been relatively neglected. Male great bowerbirds (Ptilonorhynchus nuchalis) construct bowers that exploit the female's predictable field of view (FOV) during courtship displays by creating forced perspective illusions, and the quality of illusion is a good predictor of mating success. Here, we present and discuss two additional components of male courtship displays that use the female's predetermined viewpoint: (i) the rapid and diverse flashing of coloured objects within her FOV and (ii) chromatic adaptation of the female's eyes that alters her perception of the colour of the displayed objects. Neither is directly related to mating success, but both are likely to increase signal efficacy, and may also be associated with attracting and holding the female's attention. Signal efficacy is constrained by trade-offs between the signal components; there are both positive and negative interactions within multicomponent signals. Important signal components may have a threshold effect on fitness rather than the often assumed linear relationship. PMID:24695430
Chen, Xianzhong
2017-01-01
ABSTRACT The cell surface serves as a functional interface between the inside and the outside of the cell. Within the past 20 y the ability of yeast (Saccharomyces cerevisiae) to display heterologous proteins on the cell surface has been demonstrated. Furthermore, S. cerevisiae has been both developed and applied in expression of various proteins on the cell surface. Using this novel and useful strategy, proteins and peptides of various kinds can be displayed on the yeast cell surface by fusing the protein of interest with the glycosylphosphatidylinositol (GPI)-anchoring system. Consolidated bioprocessing (CBP) using S. cerevisiae represents a promising technology for bioethanol production. However, further work is needed to improve the fermentation performance. There is some excellent previous research regarding construction of yeast biocatalyst using the surface display system to decrease cost, increase efficiency of ethanol production and directly utilize starch or biomass for fuel production. In this commentary, we reviewed the yeast surface display system and highlighted recent work. Additionally, the strategy for decrease of phytate phosphate content in dried distillers grains with solubles (DDGS) by display of phytase on the yeast cell surface is discussed. PMID:27459271
Development of a multipurpose scaffold for the display of peptide loops
Rossmann, Maxim; J. Greive, Sandra; Moschetti, Tommaso; Dinan, Michael
2017-01-01
Abstract Protein–protein interactions (PPIs) determine a wide range of biological processes and analysis of these dynamic networks is increasingly becoming a mandatory tool for studying protein function. Using the globular ATPase domain of recombinase RadA as a scaffold, we have developed a peptide display system (RAD display), which allows for the presentation of target peptides, protein domains or full-length proteins and their rapid recombinant production in bacteria. The design of the RAD display system includes differently tagged versions of the scaffold, which allows for flexibility in the protein purification method, and chemical coupling for small molecule labeling or surface immobilization. When combined with the significant thermal stability of the RadA protein, these features create a versatile multipurpose scaffold system. Using various orthogonal biophysical techniques, we show that peptides displayed on the scaffold bind to their natural targets in a fashion similar to linear parent peptides. We use the examples of CK2β/CK2α kinase and TPX2/Aurora A kinase protein complexes to demonstrate that the peptide displayed by the RAD scaffold can be used in PPI studies with the same binding efficacy but at lower costs compared with their linear synthetic counterparts. PMID:28444399
Jones, R P; Conway, D H
2005-08-01
Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the ventilators tested. In a clinical setting, high-power-output devices such as a two-way radio may cause significant interference in ventilator function. Medium-power-output devices such as mobile phones may cause minor alarm triggers. Low-power-output devices such as Bluetooth appear to cause no interference with ventilator function.
Scekic-Zahirovic, Jelena; Sendscheid, Oliver; El Oussini, Hajer; Jambeau, Mélanie; Sun, Ying; Mersmann, Sina; Wagner, Marina; Dieterlé, Stéphane; Sinniger, Jérome; Dirrig-Grosch, Sylvie; Drenner, Kevin; Birling, Marie-Christine; Qiu, Jinsong; Zhou, Yu; Li, Hairi; Fu, Xiang-Dong; Rouaux, Caroline; Shelkovnikova, Tatyana; Witting, Anke; Ludolph, Albert C; Kiefer, Friedemann; Storkebaum, Erik; Lagier-Tourenne, Clotilde; Dupuis, Luc
2016-05-17
FUS is an RNA-binding protein involved in amyotrophic lateral sclerosis (ALS) and frontotemporal dementia (FTD). Cytoplasmic FUS-containing aggregates are often associated with concomitant loss of nuclear FUS Whether loss of nuclear FUS function, gain of a cytoplasmic function, or a combination of both lead to neurodegeneration remains elusive. To address this question, we generated knockin mice expressing mislocalized cytoplasmic FUS and complete FUS knockout mice. Both mouse models display similar perinatal lethality with respiratory insufficiency, reduced body weight and length, and largely similar alterations in gene expression and mRNA splicing patterns, indicating that mislocalized FUS results in loss of its normal function. However, FUS knockin mice, but not FUS knockout mice, display reduced motor neuron numbers at birth, associated with enhanced motor neuron apoptosis, which can be rescued by cell-specific CRE-mediated expression of wild-type FUS within motor neurons. Together, our findings indicate that cytoplasmic FUS mislocalization not only leads to nuclear loss of function, but also triggers motor neuron death through a toxic gain of function within motor neurons. © 2016 The Authors. Published under the terms of the CC BY NC ND 4.0 license.
The Human Thalamus Is an Integrative Hub for Functional Brain Networks
Bertolero, Maxwell A.
2017-01-01
The thalamus is globally connected with distributed cortical regions, yet the functional significance of this extensive thalamocortical connectivity remains largely unknown. By performing graph-theoretic analyses on thalamocortical functional connectivity data collected from human participants, we found that most thalamic subdivisions display network properties that are capable of integrating multimodal information across diverse cortical functional networks. From a meta-analysis of a large dataset of functional brain-imaging experiments, we further found that the thalamus is involved in multiple cognitive functions. Finally, we found that focal thalamic lesions in humans have widespread distal effects, disrupting the modular organization of cortical functional networks. This converging evidence suggests that the human thalamus is a critical hub region that could integrate diverse information being processed throughout the cerebral cortex as well as maintain the modular structure of cortical functional networks. SIGNIFICANCE STATEMENT The thalamus is traditionally viewed as a passive relay station of information from sensory organs or subcortical structures to the cortex. However, the thalamus has extensive connections with the entire cerebral cortex, which can also serve to integrate information processing between cortical regions. In this study, we demonstrate that multiple thalamic subdivisions display network properties that are capable of integrating information across multiple functional brain networks. Moreover, the thalamus is engaged by tasks requiring multiple cognitive functions. These findings support the idea that the thalamus is involved in integrating information across cortical networks. PMID:28450543
2017-01-01
A large number of routing-related surveys are published so far for Wireless Sensor Networks (WSNs) that exhibit either complete or partial emphasis on routing in WSNs. These surveys classify and discuss the relevant routing protocols published mainly in the fields of classical, energy efficient, secure, hierarchical, geographic, intelligent, Quality of Service (QoS)-based and multipath WSNs. However, to the best of our knowledge, no study is presented so far which may clearly categorize the routing-related survey literature for WSNs.To fill this gap, an effort is made in this paper for presenting an in-depth review of already published routing-related survey literature in WSNs. Our review initially proposes a generalized survey design model and afterwards analyzes the routing-related survey literature in the light of the devised General Survey Design Framework (GSDF). Such an analysis describes the design soundness of the published routing-related surveys. Therefore, our review puts forth an original classification based on the frequency-of-survey-publication and taxonomizes the corresponding routing-related fields into high, medium and low focused areas of survey publication in WSNs. Furthermore, the surveys belonging to each main category are sub-categorized into various sub-classes and briefly discussed according to their design characteristics. On the one hand, this review is useful for beginners who may easily explore the already published routing-related survey literature in WSNs in a single document and investigate it by spending less effort. On the other hand, it is useful for expert researchers who may explore the trends and frequency of writing surveys in different areas of routing in WSNs. The experts may explore those areas of routing which are either neglected or least focused or lack in design soundness as per general survey design framework. In the end, insights and future research directions are outlined and a reasonable conclusion is put forth which may outline guiding principles for routing-related survey research in future. PMID:28933763
Rehan, Waqas; Fischer, Stefan; Rehan, Maaz
2017-07-26
A large number of routing-related surveys are published so far for Wireless Sensor Networks (WSNs) that exhibit either complete or partial emphasis on routing in WSNs. These surveys classify and discuss the relevant routing protocols published mainly in the fields of classical, energy efficient, secure, hierarchical, geographic, intelligent, Quality of Service (QoS)-based and multipath WSNs. However, to the best of our knowledge, no study is presented so far which may clearly categorize the routing-related survey literature for WSNs.To fill this gap, an effort is made in this paper for presenting an in-depth review of already published routing-related survey literature in WSNs. Our review initially proposes a generalized survey design model and afterwards analyzes the routing-related survey literature in the light of the devised General Survey Design Framework (GSDF) . Such an analysis describes the design soundness of the published routing-related surveys. Therefore, our review puts forth an original classification based on the frequency-of-survey-publication and taxonomizes the corresponding routing-related fields into high, medium and low focused areas of survey publication in WSNs. Furthermore, the surveys belonging to each main category are sub-categorized into various sub-classes and briefly discussed according to their design characteristics. On the one hand, this review is useful for beginners who may easily explore the already published routing-related survey literature in WSNs in a single document and investigate it by spending less effort. On the other hand, it is useful for expert researchers who may explore the trends and frequency of writing surveys in different areas of routing in WSNs. The experts may explore those areas of routing which are either neglected or least focused or lack in design soundness as per general survey design framework. In the end, insights and future research directions are outlined and a reasonable conclusion is put forth which may outline guiding principles for routing-related survey research in future.
Application of multi-function display and control technology
NASA Technical Reports Server (NTRS)
Spiger, R. J.; Farrell, R. J.; Holcomb, G. A.
1982-01-01
The NASA orbiter spacecraft incorporates a complex array of systems, displays, and controls. The incorporation of discrete dedicated controls into a multifunction display and control system (MFDCS) offers the potential for savings in weight, power, panel space, and crew training time. Technology identified as applicable to a MFDCS is applied to the orbiter orbital maneuvering system (OMS) and the electrical power distribution and control system (EPDCS) to derive concepts for a MFDCS design. Several concepts of varying degrees of performance and complexity are discussed and a suggested concept for further development is presented in greater detail. Both the hardware and software aspects and the human factors considerations of the designs are included.
AMPS data management concepts. [Atmospheric, Magnetospheric and Plasma in Space experiment
NASA Technical Reports Server (NTRS)
Metzelaar, P. N.
1975-01-01
Five typical AMPS experiments were formulated to allow simulation studies to verify data management concepts. Design studies were conducted to analyze these experiments in terms of the applicable procedures, data processing and displaying functions. Design concepts for AMPS data management system are presented which permit both automatic repetitive measurement sequences and experimenter-controlled step-by-step procedures. Extensive use is made of a cathode ray tube display, the experimenters' alphanumeric keyboard, and the computer. The types of computer software required by the system and the possible choices of control and display procedures available to the experimenter are described for several examples. An electromagnetic wave transmission experiment illustrates the methods used to analyze data processing requirements.
Interactive displays in medical art
NASA Technical Reports Server (NTRS)
Mcconathy, Deirdre Alla; Doyle, Michael
1989-01-01
Medical illustration is a field of visual communication with a long history. Traditional medical illustrations are static, 2-D, printed images; highly realistic depictions of the gross morphology of anatomical structures. Today medicine requires the visualization of structures and processes that have never before been seen. Complex 3-D spatial relationships require interpretation from 2-D diagnostic imagery. Pictures that move in real time have become clinical and research tools for physicians. Medical illustrators are involved with the development of interactive visual displays for three different, but not discrete, functions: as educational materials, as clinical and research tools, and as data bases of standard imagery used to produce visuals. The production of interactive displays in the medical arts is examined.
Displays. [three dimensional analog visual system for aiding pilot space perception
NASA Technical Reports Server (NTRS)
1974-01-01
An experimental investigation made to determine the depth cue of a head movement perspective and image intensity as a function of depth is summarized. The experiment was based on the use of a hybrid computer generated contact analog visual display in which various perceptual depth cues are included on a two dimensional CRT screen. The system's purpose was to impart information, in an integrated and visually compelling fashion, about the vehicle's position and orientation in space. Results show head movement gives a 40% improvement in depth discrimination when the display is between 40 and 100 cm from the subject; intensity variation resulted in as much improvement as head movement.
Loop Mirror Laser Neural Network with a Fast Liquid-Crystal Display
NASA Astrophysics Data System (ADS)
Mos, Evert C.; Schleipen, Jean J. H. B.; de Waardt, Huug; Khoe, Djan G. D.
1999-07-01
In our laser neural network (LNN) all-optical threshold action is obtained by application of controlled optical feedback to a laser diode. Here an extended experimental LNN is presented with as many as 32 neurons and 12 inputs. In the setup we use a fast liquid-crystal display to implement an optical matrix vector multiplier. This display, based on ferroelectric liquid-crystal material, enables us to present 125 training examples s to the LNN. To maximize the optical feedback efficiency of the setup, a loop mirror is introduced. We use a -rule learning algorithm to train the network to perform a number of functions toward the application area of telecommunication data switching.
Evidence for global processing of complex visual displays
NASA Technical Reports Server (NTRS)
Munson, Robert C.; Horst, Richard L.
1986-01-01
'Polar graphic' displays, in which changes in system status are represented by distortions in the form of a geometric figure, were presented to subjects, and reaction time (RT) to discriminate system status was recorded. Of interest was the extent to which reaction time showed evidence of global processing of these displays as the number of nodes and difficulty of discrimination were varied. When discrimination of system status was easy, RT showed no increase with increasing number of nodes, providing evidence of global processing. When discrimination was difficult, systematic differences in RT as a function of the number of nodes suggested the invocation of other (local) processes, although the data were not consistent with a node-by-node search process.
Improved memory loading techniques for the TSRV display system
NASA Technical Reports Server (NTRS)
Easley, W. C.; Lynn, W. A.; Mcluer, D. G.
1986-01-01
A recent upgrade of the TSRV research flight system at NASA Langley Research Center retained the original monochrome display system. However, the display memory loading equipment was replaced requiring design and development of new methods of performing this task. This paper describes the new techniques developed to load memory in the display system. An outdated paper tape method for loading the BOOTSTRAP control program was replaced by EPROM storage of the characters contained on the tape. Rather than move a tape past an optical reader, a counter was implemented which steps sequentially through EPROM addresses and presents the same data to the loader circuitry. A cumbersome cassette tape method for loading the applications software was replaced with a floppy disk method using a microprocessor terminal installed as part of the upgrade. The cassette memory image was transferred to disk and a specific software loader was written for the terminal which duplicates the function of the cassette loader.
Venter, P. Arno; Dirksen, Anouk; Thomas, Diane; Manchester, Marianne; Dawson, Philip E.; Schneemann, Anette
2011-01-01
Multivalent display of heterologous proteins on viral nanoparticles forms a basis for numerous applications in nanotechnology, including vaccine development, targeted therapeutic delivery and tissue-specific bio-imaging. In many instances, precise placement of proteins is required for optimal functioning of the supramolecular assemblies, but orientation- and site-specific coupling of proteins to viral scaffolds remains a significant technical challenge. We have developed two strategies that allow for controlled attachment of a variety of proteins on viral particles using covalent and noncovalent principles. In one strategy, an interaction between domain 4 of anthrax protective antigen and its receptor was used to display multiple copies of a target protein on virus-like particles. In the other, expressed protein ligation and aniline-catalyzed oximation was used to covalently display a model protein. The latter strategy, in particular, yielded nanoparticles that induced potent immune responses to the coupled protein, suggesting potential applications in vaccine development. PMID:21545187
Piloted evaluation of an integrated propulsion and flight control simulator
NASA Technical Reports Server (NTRS)
Bright, Michelle M.; Simon, Donald L.
1992-01-01
This paper describes a piloted evaluation of the integrated flight and propulsion control simulator at NASA Lewis Research Center. The purpose of this evaluation is to demonstrate the suitability and effectiveness of this fixed based simulator for advanced integrated propulsion and airframe control design. The evaluation will cover control effector gains and deadbands, control effectiveness and control authority, and heads up display functionality. For this evaluation the flight simulator is configured for transition flight using an advanced Short Take-Off and vertical Landing fighter aircraft model, a simplified high-bypass turbofan engine model, fighter cockpit, displays, and pilot effectors. The paper describes the piloted tasks used for rating displays and control effector gains. Pilot comments and simulation results confirm that the display symbology and control gains are very adequate for the transition flight task. Additionally, it is demonstrated that this small-scale, fixed base flight simulator facility can adequately perform a real time, piloted control evaluation.
Analysis of Behavioral Indicators as a Measure of Satiation.
Scalzo, Rachel; Davis, Tonya N
2017-03-01
Providing noncontingent access to a stimulus until an individual displays behavioral indicators of satiation has been used to determine when an abolishing operation is in effect, but there has been variation in its application in the literature. Four males diagnosed with autism spectrum disorder with tangibly maintained challenging behavior participated in this study. Individualized behavioral indicators were identified and verified to determine when each participant was finished playing with his/her preferred item. Three presession conditions were manipulated including restricted access to the tangible stimulus for 30 min, access to the tangible stimulus until the display of one behavioral indicator, and access to the tangible stimulus until the display of three behavioral indicators. Each presession condition was followed by a tangible condition of the functional analysis to measure challenging behavior. Results indicated that presession access to a tangible stimulus until the display of three behavioral indicators produced a greater abative effect on challenging behavior than one behavioral indicator.
Female preferences drive the evolution of mimetic accuracy in male sexual displays.
Coleman, Seth William; Patricelli, Gail Lisa; Coyle, Brian; Siani, Jennifer; Borgia, Gerald
2007-10-22
Males in many bird species mimic the vocalizations of other species during sexual displays, but the evolutionary and functional significance of interspecific vocal mimicry is unclear. Here we use spectrographic cross-correlation to compare mimetic calls produced by male satin bowerbirds (Ptilonorhynchus violaceus) in courtship with calls from several model species. We show that the accuracy of vocal mimicry and the number of model species mimicked are both independently related to male mating success. Multivariate analyses revealed that these mimetic traits were better predictors of male mating success than other male display traits previously shown to be important for male mating success. We suggest that preference-driven mimetic accuracy may be a widespread occurrence, and that mimetic accuracy may provide females with important information about male quality. Our findings support an alternative hypothesis to help explain a common element of male sexual displays.
Practical low-cost stereo head-mounted display
NASA Astrophysics Data System (ADS)
Pausch, Randy; Dwivedi, Pramod; Long, Allan C., Jr.
1991-08-01
A high-resolution head-mounted display has been developed from substantially cheaper components than previous systems. Monochrome displays provide 720 by 280 monochrome pixels to each eye in a one-inch-square region positioned approximately one inch from each eye. The display hardware is the Private Eye, manufactured by Reflection Technologies, Inc. The tracking system uses the Polhemus Isotrak, providing (x,y,z, azimuth, elevation and roll) information on the user''s head position and orientation 60 times per second. In combination with a modified Nintendo Power Glove, this system provides a full-functionality virtual reality/simulation system. Using two host 80386 computers, real-time wire frame images can be produced. Other virtual reality systems require roughly 250,000 in hardware, while this one requires only 5,000. Stereo is particularly useful for this system because shading or occlusion cannot be used as depth cues.
Registration of an on-axis see-through head-mounted display and camera system
NASA Astrophysics Data System (ADS)
Luo, Gang; Rensing, Noa M.; Weststrate, Evan; Peli, Eli
2005-02-01
An optical see-through head-mounted display (HMD) system integrating a miniature camera that is aligned with the user's pupil is developed and tested. Such an HMD system has a potential value in many augmented reality applications, in which registration of the virtual display to the real scene is one of the critical aspects. The camera alignment to the user's pupil results in a simple yet accurate calibration and a low registration error across a wide range of depth. In reality, a small camera-eye misalignment may still occur in such a system due to the inevitable variations of HMD wearing position with respect to the eye. The effects of such errors are measured. Calculation further shows that the registration error as a function of viewing distance behaves nearly the same for different virtual image distances, except for a shift. The impact of prismatic effect of the display lens on registration is also discussed.
Chang, Lingqian; Chen, Feng; Zhang, Xiaokang; Kuang, Tairong; Li, Mi; Hu, Jiaming; Shi, Junfeng; Lee, Ly James; Cheng, Huanyu; Li, Yiwen
2017-05-17
Extensive efforts have been devoted to the development of surfactant-free electronic ink (E-ink) with excellent display resolution for high-definition resolution display. Herein, we report the use of polydopamine-based synthetic melanin, a class of functional nanoparticles with similar chemical compositions and physical properties to those of naturally occurring melanin, as a new E-ink material. It was found that such E-ink displays could achieve ultrahigh resolution (>10 000 ppi) and low power consumption (operation voltage of only 1 V) in aqueous solutions. Interestingly, simple oxidation of synthetic melanin nanoparticles enables the generation of intrinsic fluorescence, allowing further development of fluorescent E-ink displays with nanoscale resolution. We describe these bioinspired materials in an initial proof-of-concept study and propose that synthetic melanin nanoparticles will be suitable for electronic nanoinks with a potential wide range of applications in molecular patterning and fluorescence bioimaging.
NASA Astrophysics Data System (ADS)
Chen, Shaobin; Zhang, Xubo; Wang, Wenyuan; Zhou, Chengping; Ding, Mingyue
2007-11-01
Nowadays many Geographic Information System (GIS) have been widely used in many municipal corporations. Water-supplying corporations in many cities developed GIS application system based on SiCAD/Open GIS platform several years ago for their daily management and engineering construction. With the increasing of commercial business, many corporations now need to add the functionality of three dimensional to display to their GIS System without too much financial cost. Because of the expensiveness of updating SiCAD/Open GIS system to the up-to-date version, the introduction of a third-part 3D display technology is considered. In our solution, Visualization Toolkit (VTK) is used to achieve three dimensional display of underground water-supplying network on the basis of an existing SiCAD/Open GIS system. This paper addresses on the system architecture and key implementation technologies of this solution.
Human Machine Interface Programming and Testing
NASA Technical Reports Server (NTRS)
Foster, Thomas Garrison
2013-01-01
Human Machine Interface (HMI) Programming and Testing is about creating graphical displays to mimic mission critical ground control systems in order to provide NASA engineers with the ability to monitor the health management of these systems in real time. The Health Management System (HMS) is an online interactive human machine interface system that monitors all Kennedy Ground Control Subsystem (KGCS) hardware in the field. The Health Management System is essential to NASA engineers because it allows remote control and monitoring of the health management systems of all the Programmable Logic Controllers (PLC) and associated field devices. KGCS will have equipment installed at the launch pad, Vehicle Assembly Building, Mobile Launcher, as well as the Multi-Purpose Processing Facility. I am designing graphical displays to monitor and control new modules that will be integrated into the HMS. The design of the display screen will closely mimic the appearance and functionality of the actual modules. There are many different field devices used to monitor health management and each device has its own unique set of health management related data, therefore each display must also have its own unique way to display this data. Once the displays are created, the RSLogix5000 application is used to write software that maps all the required data read from the hardware to the graphical display. Once this data is mapped to its corresponding display item, the graphical display and hardware device will be connected through the same network in order to test all possible scenarios and types of data the graphical display was designed to receive. Test Procedures will be written to thoroughly test out the displays and ensure that they are working correctly before being deployed to the field. Additionally, the Kennedy Ground Controls Subsystem's user manual will be updated to explain to the NASA engineers how to use the new module displays.
Aromatase Inhibitor-Associated Bone Fractures: A Case-Cohort GWAS and Functional Genomics
Liu, Mohan; Goss, Paul E.; Ingle, James N.; Kubo, Michiaki; Furukawa, Yoichi; Batzler, Anthony; Jenkins, Gregory D.; Carlson, Erin E.; Nakamura, Yusuke; Schaid, Daniel J.; Chapman, Judy-Anne W.; Shepherd, Lois E.; Ellis, Matthew J.; Khosla, Sundeep; Wang, Liewei
2014-01-01
Bone fractures are a major consequence of osteoporosis. There is a direct relationship between serum estrogen concentrations and osteoporosis risk. Aromatase inhibitors (AIs) greatly decrease serum estrogen levels in postmenopausal women, and increased incidence of fractures is a side effect of AI therapy. We performed a discovery case-cohort genome-wide association study (GWAS) using samples from 1071 patients, 231 cases and 840 controls, enrolled in the MA.27 breast cancer AI trial to identify genetic factors involved in AI-related fractures, followed by functional genomic validation. Association analyses identified 20 GWAS single nucleotide polymorphism (SNP) signals with P < 5E-06. After removal of signals in gene deserts and those composed entirely of imputed SNPs, we applied a functional validation “decision cascade” that resulted in validation of the CTSZ-SLMO2-ATP5E, TRAM2-TMEM14A, and MAP4K4 genes. These genes all displayed estradiol (E2)-dependent induction in human fetal osteoblasts transfected with estrogen receptor-α, and their knockdown altered the expression of known osteoporosis-related genes. These same genes also displayed SNP-dependent variation in E2 induction that paralleled the SNP-dependent induction of known osteoporosis genes, such as osteoprotegerin. In summary, our case-cohort GWAS identified SNPs in or near CTSZ-SLMO2-ATP5E, TRAM2-TMEM14A, and MAP4K4 that were associated with risk for bone fracture in estrogen receptor-positive breast cancer patients treated with AIs. These genes displayed E2-dependent induction, their knockdown altered the expression of genes related to osteoporosis, and they displayed SNP genotype-dependent variation in E2 induction. These observations may lead to the identification of novel mechanisms associated with fracture risk in postmenopausal women treated with AIs. PMID:25148458
NASA Technical Reports Server (NTRS)
Luo, Victor; Khanampornpan, Teerapat; Boehmer, Rudy A.; Kim, Rachel Y.
2011-01-01
This software graphically displays all pertinent information from a Predicted Events File (PEF) using the Java Swing framework, which allows for multi-platform support. The PEF is hard to weed through when looking for specific information and it is a desire for the MRO (Mars Reconn aissance Orbiter) Mission Planning & Sequencing Team (MPST) to have a different way to visualize the data. This tool will provide the team with a visual way of reviewing and error-checking the sequence product. The front end of the tool contains much of the aesthetically appealing material for viewing. The time stamp is displayed in the top left corner, and highlighted details are displayed in the bottom left corner. The time bar stretches along the top of the window, and the rest of the space is allotted for blocks and step functions. A preferences window is used to control the layout of the sections along with the ability to choose color and size of the blocks. Double-clicking on a block will show information contained within the block. Zooming into a certain level will graphically display that information as an overlay on the block itself. Other functions include using hotkeys to navigate, an option to jump to a specific time, enabling a vertical line, and double-clicking to zoom in/out. The back end involves a configuration file that allows a more experienced user to pre-define the structure of a block, a single event, or a step function. The individual will have to determine what information is important within each block and what actually defines the beginning and end of a block. This gives the user much more flexibility in terms of what the tool is searching for. In addition to the configurability, all the settings in the preferences window are saved in the configuration file as well
Kegler, Kristel; Imbschweiler, Ilka; Ulrich, Reiner; Kovermann, Peter; Fahlke, Christoph; Deschl, Ulrich; Kalkuhl, Arno; Baumgärnter, Wolfgang; Wewetzer, Konstantin
2014-06-01
Central nervous system (CNS) injury triggers production of myelinating Schwann cells from endogenous oligodendrocyte precursors (OLPs). These CNS Schwann cells may be attractive candidates for novel therapeutic strategies aiming to promote endogenous CNS repair. However, CNS Schwann cells have been so far mainly characterized in situ regarding morphology and marker expression, and it has remained enigmatic whether they display functional properties distinct from peripheral nervous system (PNS) Schwann cells. Potassium channels (K+) have been implicated in progenitor and glial cell proliferation after injury and may, therefore, represent a suitable pharmacological target. In the present study, we focused on the function and expression of voltage-gated K+ channels Kv(1-12) and accessory β-subunits in purified adult canine CNS and PNS Schwann cell cultures using electrophysiology and microarray analysis and characterized their antigenic phenotype. We show here that K+ channels differed significantly in both cell types. While CNS Schwann cells displayed prominent K D-mediated K+ currents, PNS Schwann cells elicited K(D-) and K(A-type) K+ currents. Inhibition of K+ currents by TEA and Ba2+ was more effective in CNS Schwann cells. These functional differences were not paralleled by differential mRNA expression of Kv(1-12) and accessory β-subunits. However, O4/A2B5 and GFAP expressions were significantly higher and lower, respectively, in CNS than in PNS Schwann cells. Taken together, this is the first evidence that CNS Schwann cells display specific properties not shared by their peripheral counterpart. Both Kv currents and increased O4/A2B5 expression were reminiscent of OLPs suggesting that CNS Schwann cells retain OLP features during maturation.
Screen Miniatures as Icons for Backward Navigation in Content-Based Software.
ERIC Educational Resources Information Center
Boling, Elizabeth; Ma, Guoping; Tao, Chia-Wen; Askun, Cengiz; Green, Tim; Frick, Theodore; Schaumburg, Heike
Users of content-based software programs, including hypertexts and instructional multimedia, rely on the navigation functions provided by the designers of those program. Typical navigation schemes use abstract symbols (arrows) to label basic navigational functions like moving forward or backward through screen displays. In a previous study, the…
EFFECT OF ATRAZINE ON OVARIAN FUNCTION IN THE RAT
The effect of the chlorotriazine herbicide, atrazine, on ovarian function was studied in Long-Evans hooded (LE-hooded) and SpragucDawley (SD) rats. Atrazine was administered by gavage for 21 d to females displaying regular 4-d estrous cycles. In both sfrains, 75 mg/kg/d disrupted...
USDA-ARS?s Scientific Manuscript database
Ecologists worldwide recognize that the novel ecosystems of the future will display radically different structure and function from ecosystems that have dominated the study of ecology up until the prsent time. Because of both abiotic and biotic obstacles, rangelands dominated by invasive plants are...
Functional Impairments in Children with ADHD: Unique Effects of Age and Comorbid Status
ERIC Educational Resources Information Center
Booster, Genery D.; DuPaul, George J.; Eiraldi, Ricardo; Power, Thomas J.
2012-01-01
Objective: Children with ADHD and comorbid disorders display poorer overall functioning compared with children with ADHD alone, though little research has examined the differential impact of externalizing versus internalizing comorbidities. Method: This study examined the impact of internalizing and externalizing comorbidities on the academic and…
Specialized Color Function for Display of Signed Data
NASA Technical Reports Server (NTRS)
Kalb, Virginia
2008-01-01
This Mathematica script defines a color function to be used with Mathematica's plotting modules for differentiating data attaining both positive and negative values. Positive values are shown as shades of blue, and negative values are shown in red. The intensity of the color reflects the absolute value of the data value.
USDA-ARS?s Scientific Manuscript database
Sulfakinin (SK) is a sulfated insect neuropeptide that is best known for its function as a satiety factor. It displays structural and functional similarities with the vertebrate peptides gastrin and cholecystokinin. Peptidomic studies in multiple insects, crustaceans and arachnids have revealed th...
Takashima, Eizo; Williams, Marni; Eiglmeier, Karin; Pain, Adrien; Guelbeogo, Wamdaogo M.; Gneme, Awa; Brito-Fravallo, Emma; Holm, Inge; Lavazec, Catherine; Sagnon, N’Fale; Baxter, Richard H.; Riehle, Michelle M.; Vernick, Kenneth D.
2015-01-01
Nucleotide variation patterns across species are shaped by the processes of natural selection, including exposure to environmental pathogens. We examined patterns of genetic variation in two sister species, Anopheles gambiae and Anopheles coluzzii, both efficient natural vectors of human malaria in West Africa. We used the differentiation signature displayed by a known coordinate selective sweep of immune genes APL1 and TEP1 in A. coluzzii to design a population genetic screen trained on the sweep, classified a panel of 26 potential immune genes for concordance with the signature, and functionally tested their immune phenotypes. The screen results were strongly predictive for genes with protective immune phenotypes: genes meeting the screen criteria were significantly more likely to display a functional phenotype against malaria infection than genes not meeting the criteria (p = 0.0005). Thus, an evolution-based screen can efficiently prioritize candidate genes for labor-intensive downstream functional testing, and safely allow the elimination of genes not meeting the screen criteria. The suite of immune genes with characteristics similar to the APL1-TEP1 selective sweep appears to be more widespread in the A. coluzzii genome than previously recognized. The immune gene differentiation may be a consequence of adaptation of A. coluzzii to new pathogens encountered in its niche expansion during the separation from A. gambiae, although the role, if any of natural selection by Plasmodium is unknown. Application of the screen allowed identification of new functional immune factors, and assignment of new functions to known factors. We describe biochemical binding interactions between immune proteins that underlie functional activity for malaria infection, which highlights the interplay between pathogen specificity and the structure of immune complexes. We also find that most malaria-protective immune factors display phenotypes for either human or rodent malaria, with broad specificity a rarity. PMID:26633695
Evaluation of a pilot workload metric for simulated VTOL landing tasks
NASA Technical Reports Server (NTRS)
North, R. A.; Graffunder, K.
1979-01-01
A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Multivariate discriminant functions were formed from conventional flight performance and/or visual response variables to maximize detection of experimental differences. The flight performance variable discriminant showed maximum differentiation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition/trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus, represented higher workload levels.
Juhan, I; Bayle, J; Mattei, J F; Thevenieau, D; Perrimond, H; Muratore, R
1979-10-01
The authors report on two cases of congenital thrombopenia with radial aplasia. Both children display several formative abnormalities and a mild thrombopenia; hemorragic manifestations occurred in the first case only. Megacryoblastic to platelets series, as studied with electronic microscopy, show small-sized, "microcytic" and hypogranular megacaryocytes, displaying a maturative disorder (dysmegacaryocytopoiesis). In functional studies, platelets of the first patient show an imperfect nucleotidic release and do not agregate normally with ristocetin. The second case exhibits mostly a PF3 reduction. The variety of expression of the megacaryocytic-platelets disorders appears likewise in the squelettal and visceral malformations. The whole disorder could be ascribed to a pleiotropic abnormal gene with a variable expressivity.
Ethernet based data logger for gaseous detectors
NASA Astrophysics Data System (ADS)
Swain, S.; Sahu, P. K.; Sahu, S. K.
2018-05-01
A data logger is designed to monitor and record ambient parameters such as temperature, pressure and relative humidity along with gas flow rate as a function of time. These parameters are required for understanding the characteristics of gas-filled detectors such as Gas Electron Multiplier (GEM) and Multi-Wire Proportional Counter (MWPC). The data logger has different microcontrollers and has been interfaced to an ethernet port with a local LCD unit for displaying all measured parameters. In this article, the explanation of the data logger design, hardware, and software description of the master microcontroller and the DAQ system along with LabVIEW interface client program have been presented. We have implemented this device with GEM detector and displayed few preliminary results as a function of above parameters.
Multifocal planes head-mounted displays.
Rolland, J P; Krueger, M W; Goon, A
2000-07-01
Stereoscopic head-mounted displays (HMD's) provide an effective capability to create dynamic virtual environments. For a user of such environments, virtual objects would be displayed ideally at the appropriate distances, and natural concordant accommodation and convergence would be provided. Under such image display conditions, the user perceives these objects as if they were objects in a real environment. Current HMD technology requires convergent eye movements. However, it is currently limited by fixed visual accommodation, which is inconsistent with real-world vision. A prototype multiplanar volumetric projection display based on a stack of laminated planes was built for medical visualization as discussed in a paper presented at a 1999 Advanced Research Projects Agency workshop (Sullivan, Advanced Research Projects Agency, Arlington, Va., 1999). We show how such technology can be engineered to create a set of virtual planes appropriately configured in visual space to suppress conflicts of convergence and accommodation in HMD's. Although some scanning mechanism could be employed to create a set of desirable planes from a two-dimensional conventional display, multiplanar technology accomplishes such function with no moving parts. Based on optical principles and human vision, we present a comprehensive investigation of the engineering specification of multiplanar technology for integration in HMD's. Using selected human visual acuity and stereoacuity criteria, we show that the display requires at most 27 equally spaced planes, which is within the capability of current research and development display devices, located within a maximal 26-mm-wide stack. We further show that the necessary in-plane resolution is of the order of 5 microm.
Lateralisation of aggressive displays in a tephritid fly
NASA Astrophysics Data System (ADS)
Benelli, Giovanni; Donati, Elisa; Romano, Donato; Stefanini, Cesare; Messing, Russell H.; Canale, Angelo
2015-02-01
Lateralisation (i.e. different functional and/or structural specialisations of the left and right sides of the brain) of aggression has been examined in several vertebrate species, while evidence for invertebrates is scarce. In this study, we investigated lateralisation of aggressive displays (boxing with forelegs and wing strikes) in the Mediterranean fruit fly, Ceratitis capitata. We attempted to answer the following questions: (1) do medflies show lateralisation of aggressive displays at the population-level; (2) are there sex differences in lateralisation of aggressive displays; and (3) does lateralisation of aggression enhance fighting success? Results showed left-biased population-level lateralisation of aggressive displays, with no consistent differences among sexes. In both male-male and female-female conflicts, aggressive behaviours performed with left body parts led to greater fighting success than those performed with right body parts. As we found left-biased preferential use of body parts for both wing strikes and boxing, we predicted that the left foreleg/wing is quicker in exploring/striking than the right one. We characterised wing strike and boxing using high-speed videos, calculating mean velocity of aggressive displays. For both sexes, aggressive displays that led to success were faster than unsuccessful ones. However, left wing/legs were not faster than right ones while performing aggressive acts. Further research is needed on proximate causes allowing enhanced fighting success of lateralised aggressive behaviour. This is the first report supporting the adaptive role of lateralisation of aggressive displays in insects.
Bautista, Luis Fernando; Morales, Gabriel; Sanz, Raquel
2015-10-01
A covalent immobilization method based on glutaraldehyde and amino-functionalized SBA-15 supports has been successfully applied to covalently and stably immobilize laccase from Trametes versicolor. The resultant biocatalysts displayed high incorporation yields of enzyme and led to excellent biodegradation rates of selected HPAs models, i.e. naphthalene, phenanthrene and anthracene, in water. The nature of the hydrocarbon chain accompanying the amino group has been shown as determinant for the immobilization as well as for the activity and reusability of the materials. Thus, alkyl moieties displayed higher enzyme loadings than phenyl moieties, being more adequate the larger n-butyl tethering residue likely due to its higher mobility. Using the aminobutyl-based laccase-SBA-15, 82%, 73%, and 55% conversion of naphthalene, phenanthrene and anthracene, respectively, were achieved after 48 h, very close to the values obtained with free laccase under the same reaction conditions. On the other hand, aminopropyl-based laccase-SBA-15 biocatalysts displayed the best reusability properties, retaining higher activity after four repeated uses than the corresponding aminobutyl-based materials. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cardall, Christian Y.; Budiardja, Reuben D.
2017-05-01
GenASiS Basics provides Fortran 2003 classes furnishing extensible object-oriented utilitarian functionality for large-scale physics simulations on distributed memory supercomputers. This functionality includes physical units and constants; display to the screen or standard output device; message passing; I/O to disk; and runtime parameter management and usage statistics. This revision -Version 2 of Basics - makes mostly minor additions to functionality and includes some simplifying name changes.
Payload Operations Control Center (POCC). [spacelab flight operations
NASA Technical Reports Server (NTRS)
Shipman, D. L.; Noneman, S. R.; Terry, E. S.
1981-01-01
The Spacelab payload operations control center (POCC) timeline analysis program which is used to provide POCC activity and resource information as a function of mission time is described. This program is fully automated and interactive, and is equipped with tutorial displays. The tutorial displays are sufficiently detailed for use by a program analyst having no computer experience. The POCC timeline analysis program is designed to operate on the VAX/VMS version V2.1 computer system.
Progesterone Receptor Scaffolding Function in Breast Cancer
2011-10-01
shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number...NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON USAMRMC a . REPORT U b. ABSTRACT U c. THIS PAGE U UU 19b. TELEPHONE NUMBER (include... a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1
Design of retinal-projection-based near-eye display with contact lens.
Wu, Yuhang; Chen, Chao Ping; Mi, Lantian; Zhang, Wenbo; Zhao, Jingxin; Lu, Yifan; Guo, Weiqian; Yu, Bing; Li, Yang; Maitlo, Nizamuddin
2018-04-30
We propose a design of a retinal-projection-based near-eye display for achieving ultra-large field of view, vision correction, and occlusion. Our solution is highlighted by a contact lens combo, a transparent organic light-emitting diode panel, and a twisted nematic liquid crystal panel. Its design rules are set forth in detail, followed by the results and discussion regarding the field of view, angular resolution, modulation transfer function, contrast ratio, distortion, and simulated imaging.
NASA Technical Reports Server (NTRS)
Spiger, R. J.; Farrell, R. J.; Holcomb, G. A.
1982-01-01
The access schema developed to access both individual switch functions as well as automated or semiautomated procedures for the orbital maneuvering system and electrical power and distribution and control system discussed and the operation of the system is described. Feasibility tests and analyses used to define display parameters and to select applicable hardware choices for use in such a system are presented and the results are discussed.
NASA Technical Reports Server (NTRS)
Guan, Changhui; Rosen, Elizabeth S.; Boonsirichai, Kanokporn; Poff, Kenneth L.; Masson, Patrick H.
2003-01-01
The arl2 mutants of Arabidopsis display altered root and hypocotyl gravitropism, whereas their inflorescence stems are fully gravitropic. Interestingly, mutant roots respond like the wild type to phytohormones and an inhibitor of polar auxin transport. Also, their cap columella cells accumulate starch similarly to wild-type cells, and mutant hypocotyls display strong phototropic responses to lateral light stimulation. The ARL2 gene encodes a DnaJ-like protein similar to ARG1, another protein previously implicated in gravity signal transduction in Arabidopsis seedlings. ARL2 is expressed at low levels in all organs of seedlings and plants. arl2-1 arg1-2 double mutant roots display kinetics of gravitropism similar to those of single mutants. However, double mutants carrying both arl2-1 and pgm-1 (a mutation in the starch-biosynthetic gene PHOSPHOGLUCOMUTASE) at the homozygous state display a more pronounced root gravitropic defect than the single mutants. On the other hand, seedlings with a null mutation in ARL1, a paralog of ARG1 and ARL2, behave similarly to the wild type in gravitropism and other related assays. Taken together, the results suggest that ARG1 and ARL2 function in the same gravity signal transduction pathway in the hypocotyl and root of Arabidopsis seedlings, distinct from the pathway involving PGM.
Satellite Data Processing System (SDPS) users manual V1.0
NASA Technical Reports Server (NTRS)
Caruso, Michael; Dunn, Chris
1989-01-01
SDPS is a menu driven interactive program designed to facilitate the display and output of image and line-based data sets common to telemetry, modeling and remote sensing. This program can be used to display up to four separate raster images and overlay line-based data such as coastlines, ship tracks and velocity vectors. The program uses multiple windows to communicate information with the user. At any given time, the program may have up to four image display windows as well as auxiliary windows containing information about each image displayed. SDPS is not a commercial program. It does not contain complete type checking or error diagnostics which may allow the program to crash. Known anomalies will be mentioned in the appropriate section as notes or cautions. SDPS was designed to be used on Sun Microsystems Workstations running SunView1 (Sun Visual/Integrated Environment for Workstations). It was primarily designed to be used on workstations equipped with color monitors, but most of the line-based functions and several of the raster-based functions can be used with monochrome monitors. The program currently runs on Sun 3 series workstations running Sun OS 4.0 and should port easily to Sun 4 and Sun 386 series workstations with SunView1. Users should also be familiar with UNIX, Sun workstations and the SunView window system.
2010-01-01
Background The assembly and spatial organization of enzymes in naturally occurring multi-protein complexes is of paramount importance for the efficient degradation of complex polymers and biosynthesis of valuable products. The degradation of cellulose into fermentable sugars by Clostridium thermocellum is achieved by means of a multi-protein "cellulosome" complex. Assembled via dockerin-cohesin interactions, the cellulosome is associated with the cell surface during cellulose hydrolysis, forming ternary cellulose-enzyme-microbe complexes for enhanced activity and synergy. The assembly of recombinant cell surface displayed cellulosome-inspired complexes in surrogate microbes is highly desirable. The model organism Lactococcus lactis is of particular interest as it has been metabolically engineered to produce a variety of commodity chemicals including lactic acid and bioactive compounds, and can efficiently secrete an array of recombinant proteins and enzymes of varying sizes. Results Fragments of the scaffoldin protein CipA were functionally displayed on the cell surface of Lactococcus lactis. Scaffolds were engineered to contain a single cohesin module, two cohesin modules, one cohesin and a cellulose-binding module, or only a cellulose-binding module. Cell toxicity from over-expression of the proteins was circumvented by use of the nisA inducible promoter, and incorporation of the C-terminal anchor motif of the streptococcal M6 protein resulted in the successful surface-display of the scaffolds. The facilitated detection of successfully secreted scaffolds was achieved by fusion with the export-specific reporter staphylococcal nuclease (NucA). Scaffolds retained their ability to associate in vivo with an engineered hybrid reporter enzyme, E. coli β-glucuronidase fused to the type 1 dockerin motif of the cellulosomal enzyme CelS. Surface-anchored complexes exhibited dual enzyme activities (nuclease and β-glucuronidase), and were displayed with efficiencies approaching 104 complexes/cell. Conclusions We report the successful display of cellulosome-inspired recombinant complexes on the surface of Lactococcus lactis. Significant differences in display efficiency among constructs were observed and attributed to their structural characteristics including protein conformation and solubility, scaffold size, and the inclusion and exclusion of non-cohesin modules. The surface-display of functional scaffold proteins described here represents a key step in the development of recombinant microorganisms capable of carrying out a variety of metabolic processes including the direct conversion of cellulosic substrates into fuels and chemicals. PMID:20840763
Solar active region display system
NASA Astrophysics Data System (ADS)
Golightly, M.; Raben, V.; Weyland, M.
2003-04-01
The Solar Active Region Display System (SARDS) is a client-server application that automatically collects a wide range of solar data and displays it in a format easy for users to assimilate and interpret. Users can rapidly identify active regions of interest or concern from color-coded indicators that visually summarize each region's size, magnetic configuration, recent growth history, and recent flare and CME production. The active region information can be overlaid onto solar maps, multiple solar images, and solar difference images in orthographic, Mercator or cylindrical equidistant projections. Near real-time graphs display the GOES soft and hard x-ray flux, flare events, and daily F10.7 value as a function of time; color-coded indicators show current trends in soft x-ray flux, flare temperature, daily F10.7 flux, and x-ray flare occurrence. Through a separate window up to 4 real-time or static graphs can simultaneously display values of KP, AP, daily F10.7 flux, GOES soft and hard x-ray flux, GOES >10 and >100 MeV proton flux, and Thule neutron monitor count rate. Climatologic displays use color-valued cells to show F10.7 and AP values as a function of Carrington/Bartel's rotation sequences - this format allows users to detect recurrent patterns in solar and geomagnetic activity as well as variations in activity levels over multiple solar cycles. Users can customize many of the display and graph features; all displays can be printed or copied to the system's clipboard for "pasting" into other applications. The system obtains and stores space weather data and images from sources such as the NOAA Space Environment Center, NOAA National Geophysical Data Center, the joint ESA/NASA SOHO spacecraft, and the Kitt Peak National Solar Observatory, and can be extended to include other data series and image sources. Data and images retrieved from the system's database are converted to XML and transported from a central server using HTTP and SOAP protocols, allowing operation through network firewalls; data is compressed to enhance performance over limited bandwidth connections. All applications and services are written in the JAVA program language for platform independence. Several versions of SARDS have been in operational use by the NASA Space Radiation Analysis Group, NOAA Space Weather Operations, and U.S. Air Force Weather Agency since 1999.
NASA Technical Reports Server (NTRS)
Paga Marrero, Hector Jose
2013-01-01
The Master Console oversees the function of Computer Systems in Firing room 1 (FR1). Master Console Operators, MCOs' for short, are our customer. I was integrated into the System Monitoring and Control (SMC) software team that is under the guidance of David Slaiman, who is the product group lead. I have been brought up to speed with System Monitoring and Control. The initial time spent reading SMC software design description and understanding how it works. The current Firing Room 1 Console Display is a floor layout giving the MCO two essential pieces of information which are Health and Status. When an issue arises, the MCO has to look on the display to find which console is affected and then the MCO must use the Reference designator from the display to manually search for the Portal Workstation (PWS) installed in the console using the hardware map; which is a long process to lookup a PWS if an issue is present. My project is to make the FR1 Console Display easier for the MCO's to pinpoint PWS's without having to lookup additional resources in the process. My project also includes updating Firing Room 1 Console Display to include the F1R Non-Redundant Set. The display does not have good use of space and functionality. PWS numbers were not present in the previous design and are the critical component in efficient understanding and administration of the consoles. Part of the process includes getting feedback from the customer, instead of just emailing them with a question, we made a proposal with changes so they could respond and give us their input; which proved to be an effective method for engaging them. In order to do this I had to use the Display Editor (DE) tool developed by NASA, Paint.Net and Visio. The process I have been using has been Visio to alter the floor layout of Firing Room and take advantage of the white areas, and then I take the altered floor plan into Paint.Net. Once in Paint.Net I put the new floor plan as a background to the standard console display. Paint.Net also serves as a tool to create the new service state bars for the new background; finally I used the DE to assemble everything and setup the right CUI's for each PWS.
Design of integrated eye tracker-display device for head mounted systems
NASA Astrophysics Data System (ADS)
David, Y.; Apter, B.; Thirer, N.; Baal-Zedaka, I.; Efron, U.
2009-08-01
We propose an Eye Tracker/Display system, based on a novel, dual function device termed ETD, which allows sharing the optical paths of the Eye tracker and the display and on-chip processing. The proposed ETD design is based on a CMOS chip combining a Liquid-Crystal-on-Silicon (LCoS) micro-display technology with near infrared (NIR) Active Pixel Sensor imager. The ET operation allows capturing the Near IR (NIR) light, back-reflected from the eye's retina. The retinal image is then used for the detection of the current direction of eye's gaze. The design of the eye tracking imager is based on the "deep p-well" pixel technology, providing low crosstalk while shielding the active pixel circuitry, which serves the imaging and the display drivers, from the photo charges generated in the substrate. The use of the ETD in the HMD Design enables a very compact design suitable for Smart Goggle applications. A preliminary optical, electronic and digital design of the goggle and its associated ETD chip and digital control, are presented.
How to use a phase-only spatial light modulator as a color display.
Harm, Walter; Jesacher, Alexander; Thalhammer, Gregor; Bernet, Stefan; Ritsch-Marte, Monika
2015-02-15
We demonstrate that a parallel aligned liquid crystal on silicon (PA-LCOS) spatial light modulator (SLM) without any attached color mask can be used as a full color display with white light illumination. The method is based on the wavelength dependence of the (voltage controlled) birefringence of the liquid crystal pixels. Modern SLMs offer a wide range over which the birefringence can be modulated, leading (in combination with a linear polarizer) to several intensity modulation periods of a reflected light wave as a function of the applied voltage. Because of dispersion, the oscillation period strongly depends on the wavelength. Thus each voltage applied to an SLM pixel corresponds to another reflected color spectrum. For SLMs with a sufficiently broad tuning range, one obtains a color palette (i.e., a "color lookup-table"), which allows one to display color images. An advantage over standard liquid crystal displays (LCDs), which use color masks in front of the individual pixels, is that the light efficiency and the display resolution are increased by a factor of three.
NASA Technical Reports Server (NTRS)
Liao, Min-Ju; Johnson, Walter W.
2004-01-01
The present study investigated the effects of droplines on target acquisition performance on a 3-D perspective display in which participants were required to move a cursor into a target cube as quickly as possible. Participants' performance and coordination strategies were characterized using both Fitts' law and acquisition patterns of the 3 viewer-centered target display dimensions (azimuth, elevation, and range). Participants' movement trajectories were recorded and used to determine movement times for acquisitions of the entire target and of each of its display dimensions. The goodness of fit of the data to a modified Fitts function varied widely among participants, and the presence of droplines did not have observable impacts on the goodness of fit. However, droplines helped participants navigate via straighter paths and particularly benefited range dimension acquisition. A general preference for visually overlapping the target with the cursor prior to capturing the target was found. Potential applications of this research include the design of interactive 3-D perspective displays in which fast and accurate selection and manipulation of content residing at multiple ranges may be a challenge.
Technical trends of large-size photomasks for flat panel displays
NASA Astrophysics Data System (ADS)
Yoshida, Koichiro
2017-06-01
Currently, flat panel displays (FPDs) are one of the main parts for information technology devices and sets. From 1990's to 2000's, liquid crystal displays (LCDs) and plasma displays had been mainstream FPDs. In the middle of 2000's, demand of plasma displays declined and organic light emitting diodes (OLEDs) newly came into FPD market. And today, major technology of FPDs are LCDs and OLEDs. Especially for mobile devices, the penetration of OLEDs is remarkable. In FPDs panel production, photolithography is the key technology as same as LSI. Photomasks for FPDs are used not only as original master of circuit pattern, but also as a tool to form other functional structures of FPDs. Photomasks for FPDs are called as "Large Size Photomasks(LSPMs)", since the remarkable feature is " Size" which reaches over 1- meter square and over 100kg. In this report, we discuss three LSPMs technical topics with FPDs technical transition and trend. The first topics is upsizing of LSPMs, the second is the challenge for higher resolution patterning, and the last is "Multi-Tone Mask" for "Half -Tone Exposure".
Wiebrands, Michael; Malajczuk, Chris J; Woods, Andrew J; Rohl, Andrew L; Mancera, Ricardo L
2018-06-21
Molecular graphics systems are visualization tools which, upon integration into a 3D immersive environment, provide a unique virtual reality experience for research and teaching of biomolecular structure, function and interactions. We have developed a molecular structure and dynamics application, the Molecular Dynamics Visualization tool, that uses the Unity game engine combined with large scale, multi-user, stereoscopic visualization systems to deliver an immersive display experience, particularly with a large cylindrical projection display. The application is structured to separate the biomolecular modeling and visualization systems. The biomolecular model loading and analysis system was developed as a stand-alone C# library and provides the foundation for the custom visualization system built in Unity. All visual models displayed within the tool are generated using Unity-based procedural mesh building routines. A 3D user interface was built to allow seamless dynamic interaction with the model while being viewed in 3D space. Biomolecular structure analysis and display capabilities are exemplified with a range of complex systems involving cell membranes, protein folding and lipid droplets.
Maruthamuthu, Murali Kannan; Hong, Jiyeon; Arulsamy, Kulandaisamy; Somasundaram, Sivachandiran; Hong, SoonHo; Choe, Woo-Seok; Yoo, Ik-Keun
2018-04-01
Peptide-displaying Escherichia coli cells were investigated for use in adsorptive removal of bisphenol A (BPA) both in Luria-Bertani medium including BPA or ATM thermal paper eluted wastewater. Two recombinant strains were constructed with monomeric and dimeric repeats of the 7-mer BPA-binding peptide (KSLENSY), respectively. Greater than threefold increased adsorption of BPA [230.4 µmol BPA per g dry cell weight (DCW)] was found in dimeric peptide-displaying cells compared to monomeric strains (63.4 µmol per g DCW) in 15 ppm BPA solution. The selective removal of BPA from a mixture of BPA analogs (bisphenol F and bisphenol S) was verified in both monomeric and dimeric peptide-displaying cells. The binding chemistry of BPA with the peptide was assumed, based on molecular docking analysis, to be the interaction of BPA with serine and asparagine residues within the 7-mer peptide sequence. The peptide-displaying cells also functioned efficiently in thermal paper eluted wastewater containing 14.5 ppm BPA.
Eddy current testing for blade edge micro cracks of aircraft engine
NASA Astrophysics Data System (ADS)
Zhang, Wei-min; Xu, Min-dong; Gao, Xuan-yi; Jin, Xin; Qin, Feng
2017-10-01
Based on the problems of low detection efficiency in the micro cracks detection of aircraft engine blades, a differential excitation eddy current testing system was designed and developed. The function and the working principle of the system were described, the problems which contained the manufacture method of simulated cracks, signal generating, signal processing and the signal display method were described. The detection test was carried out by taking a certain model aircraft engine blade with simulated cracks as a tested specimen. The test data was processed by digital low-pass filter in the computer and the crack signals of time domain display and Lissajous figure display were acquired. By comparing the test results, it is verified that Lissajous figure display shows better performance compared to time domain display when the crack angle is small. The test results show that the eddy current testing system designed in this paper is feasible to detect the micro cracks on the aeroengine blade and can effectively improve the detection efficiency of micro cracks in the practical detection work.
Component-Based Visualization System
NASA Technical Reports Server (NTRS)
Delgado, Francisco
2005-01-01
A software system has been developed that gives engineers and operations personnel with no "formal" programming expertise, but who are familiar with the Microsoft Windows operating system, the ability to create visualization displays to monitor the health and performance of aircraft/spacecraft. This software system is currently supporting the X38 V201 spacecraft component/system testing and is intended to give users the ability to create, test, deploy, and certify their subsystem displays in a fraction of the time that it would take to do so using previous software and programming methods. Within the visualization system there are three major components: the developer, the deployer, and the widget set. The developer is a blank canvas with widget menu items that give users the ability to easily create displays. The deployer is an application that allows for the deployment of the displays created using the developer application. The deployer has additional functionality that the developer does not have, such as printing of displays, screen captures to files, windowing of displays, and also serves as the interface into the documentation archive and help system. The third major component is the widget set. The widgets are the visual representation of the items that will make up the display (i.e., meters, dials, buttons, numerical indicators, string indicators, and the like). This software was developed using Visual C++ and uses COTS (commercial off-the-shelf) software where possible.
Mc Laughlin, Patrick; Neill, Siobhan O; Fanning, Noel; Mc Garrigle, Anne Marie; Connor, Owen J O; Wyse, Gerry; Maher, Michael M
2012-04-01
Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.
Front and rear projection autostereoscopic 3D displays based on lenticular sheets
NASA Astrophysics Data System (ADS)
Wang, Qiong-Hua; Zang, Shang-Fei; Qi, Lin
2015-03-01
A front projection autostereoscopic display is proposed. The display is composed of eight projectors and a 3D-imageguided screen which having a lenticular sheet and a retro-reflective diffusion screen. Based on the optical multiplexing and de-multiplexing, the optical functions of the 3D-image-guided screen are parallax image interlacing and viewseparating, which is capable of reconstructing 3D images without quality degradation from the front direction. The operating principle, optical design calculation equations and correction method of parallax images are given. A prototype of the front projection autostereoscopic display is developed, which enhances the brightness and 3D perceptions, and improves space efficiency. The performance of this prototype is evaluated by measuring the luminance and crosstalk distribution along the horizontal direction at the optimum viewing distance. We also propose a rear projection autostereoscopic display. The display consists of eight projectors, a projection screen, and two lenticular sheets. The operation principle and calculation equations are described in detail and the parallax images are corrected by means of homography. A prototype of the rear projection autostereoscopic display is developed. The normalized luminance distributions of viewing zones from the measurement are given. Results agree well with the designed values. The prototype presents high resolution and high brightness 3D images. The research has potential applications in some commercial entertainments and movies for the realistic 3D perceptions.