Sunlight-readable display technology: a dual-use case study
NASA Astrophysics Data System (ADS)
Blanchard, Randall D.
1996-05-01
This paper describes our vision of sunlight readable color display requirements, an alternate technology that offers a high level of performance, and how we implemented it for the military avionics display market. This knowledge base and product development experience was then applied with a comparable level of performance to commercial applications. The successful dual use of this technology for these two diverse markets is presented. Details of the technical commonality and a comparison of the design and performance differences are presented. A basis for specifying the required level of performance for a sunlight readable full color display is discussed. With the objective of providing a high level of image brightness and high ambient light rejection, a display architecture using collimated light is used. The resulting designs of two military cockpit display products, with contrast ratios above 20:1 in sunlight are shown. The performance of a commercial display providing several thousand foot- Lamberts of image brightness is presented.
DeltaPhage—a novel helper phage for high-valence pIX phagemid display
Nilssen, Nicolay R.; Frigstad, Terje; Pollmann, Sylvie; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger; Løset, Geir Å.
2012-01-01
Phage display has been instrumental in discovery of novel binding peptides and folded domains for the past two decades. We recently reported a novel pIX phagemid display system that is characterized by a strong preference for phagemid packaging combined with low display levels, two key features that support highly efficient affinity selection. However, high diversity in selected repertoires are intimately coupled to high display levels during initial selection rounds. To incorporate this additional feature into the pIX display system, we have developed a novel helper phage termed DeltaPhage that allows for high-valence display on pIX. This was obtained by inserting two amber mutations close to the pIX start codon, but after the pVII translational stop, conditionally inactivating the helper phage encoded pIX. Until now, the general notion has been that display on pIX is dependent on wild-type complementation, making high-valence display unachievable. However, we found that DeltaPhage does facilitate high-valence pIX display when used with a non-suppressor host. Here, we report a side-by-side comparison with pIII display, and we find that this novel helper phage complements existing pIX phagemid display systems to allow both low and high-valence display, making pIX display a complete and efficient alternative to existing pIII phagemid display systems. PMID:22539265
DeltaPhage--a novel helper phage for high-valence pIX phagemid display.
Nilssen, Nicolay R; Frigstad, Terje; Pollmann, Sylvie; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger; Løset, Geir Å
2012-09-01
Phage display has been instrumental in discovery of novel binding peptides and folded domains for the past two decades. We recently reported a novel pIX phagemid display system that is characterized by a strong preference for phagemid packaging combined with low display levels, two key features that support highly efficient affinity selection. However, high diversity in selected repertoires are intimately coupled to high display levels during initial selection rounds. To incorporate this additional feature into the pIX display system, we have developed a novel helper phage termed DeltaPhage that allows for high-valence display on pIX. This was obtained by inserting two amber mutations close to the pIX start codon, but after the pVII translational stop, conditionally inactivating the helper phage encoded pIX. Until now, the general notion has been that display on pIX is dependent on wild-type complementation, making high-valence display unachievable. However, we found that DeltaPhage does facilitate high-valence pIX display when used with a non-suppressor host. Here, we report a side-by-side comparison with pIII display, and we find that this novel helper phage complements existing pIX phagemid display systems to allow both low and high-valence display, making pIX display a complete and efficient alternative to existing pIII phagemid display systems.
Experimental investigation of control/display augmentation effects in a compensatory tracking task
NASA Technical Reports Server (NTRS)
Garg, Sanjay; Schmidt, David K.
1988-01-01
The effects of control/display augmentation on human performance and workload have been investigated for closed-loop, continuous-tracking tasks by a real-time, man-in-the-loop simulation study. The experimental results obtained indicate that only limited improvement in actual tracking performance is obtainable through display augmentation alone; with a very high level of display augmentation, tracking error will actually deteriorate. Tracking performance improves when status information is furnished for reasonable levels of display quickening; again, very high quickening levels lead to tracking error deterioration due to the incompatibility between the status information and the quickened signal.
Evaluating display fidelity and interaction fidelity in a virtual reality game.
McMahan, Ryan P; Bowman, Doug A; Zielinski, David J; Brady, Rachael B
2012-04-01
In recent years, consumers have witnessed a technological revolution that has delivered more-realistic experiences in their own homes through high-definition, stereoscopic televisions and natural, gesture-based video game consoles. Although these experiences are more realistic, offering higher levels of fidelity, it is not clear how the increased display and interaction aspects of fidelity impact the user experience. Since immersive virtual reality (VR) allows us to achieve very high levels of fidelity, we designed and conducted a study that used a six-sided CAVE to evaluate display fidelity and interaction fidelity independently, at extremely high and low levels, for a VR first-person shooter (FPS) game. Our goal was to gain a better understanding of the effects of fidelity on the user in a complex, performance-intensive context. The results of our study indicate that both display and interaction fidelity significantly affect strategy and performance, as well as subjective judgments of presence, engagement, and usability. In particular, performance results were strongly in favor of two conditions: low-display, low-interaction fidelity (representative of traditional FPS games) and high-display, high-interaction fidelity (similar to the real world).
2012-01-01
Background Transformational leadership is conceptualized as a set of behaviors designed to inspire, energize and motivate others to achieve higher levels of functioning, and is associated with salient health-related outcomes in organizational settings. Given (a) the similarities that exist between leadership within organizational settings and parenting within families, and (b) the importance of the family environment in the promotion of adolescent health-enhancing behaviors, the purpose of this exploratory study was to examine the cross-sectional relationships between parents’ transformational leadership behaviors and adolescent dietary and physical activity behaviors. Methods 857 adolescents (aged 13–15, mean age = 14.70 yrs) completed measures of transformational parenting behaviors, healthful dietary intake and leisure-time physical activity. Regression analyses were conducted to examine relationships between family transformational leadership and adolescent health outcomes. A further ‘extreme group analysis’ was conducted by clustering families based on quartile splits. A MANCOVA (controlling for child gender) was conducted to examine differences between families displaying (a) HIGH levels of transformational parenting (consistent HIGH TP), (b) LOW levels of transformational parenting (consistent LOW TP), and (c) inconsistent levels of transformational parenting (inconsistent HIGH-LOW TP). Results Results revealed that adolescents’ perceptions of family transformational parenting were associated with both healthy dietary intake and physical activity. Adolescents who perceived their families to display the highest levels of transformational parenting (HIGH TP group) displayed greater healthy eating and physical activity behaviors than adolescents who perceived their families to display the lowest levels of transformational parenting behaviors (LOW TP group). Adolescents who perceived their families to display inconsistent levels of transformational parenting behaviors (HIGH-LOW TP group) displayed the same levels of healthy eating behaviors as those adolescents from the LOW TP group. For physical activity behaviors, adolescents who perceived their families to display inconsistent levels of transformational parenting behaviors (HIGH-LOW TP group) did not differ in terms of physical activity than those in either the HIGH TP or LOW TP group. Conclusions Family transformational parenting behaviors were positively associated with both healthful dietary intake and leisure-time physical activity levels amongst adolescents. The findings suggest that transformational leadership theory is a useful framework for understanding the relationship between family leadership behaviors and adolescent health outcomes. PMID:22546151
Morton, Katie L; Wilson, Alexandra H; Perlmutter, Lisa S; Beauchamp, Mark R
2012-04-30
Transformational leadership is conceptualized as a set of behaviors designed to inspire, energize and motivate others to achieve higher levels of functioning, and is associated with salient health-related outcomes in organizational settings. Given (a) the similarities that exist between leadership within organizational settings and parenting within families, and (b) the importance of the family environment in the promotion of adolescent health-enhancing behaviors, the purpose of this exploratory study was to examine the cross-sectional relationships between parents' transformational leadership behaviors and adolescent dietary and physical activity behaviors. 857 adolescents (aged 13-15, mean age = 14.70 yrs) completed measures of transformational parenting behaviors, healthful dietary intake and leisure-time physical activity. Regression analyses were conducted to examine relationships between family transformational leadership and adolescent health outcomes. A further 'extreme group analysis' was conducted by clustering families based on quartile splits. A MANCOVA (controlling for child gender) was conducted to examine differences between families displaying (a) HIGH levels of transformational parenting (consistent HIGH TP), (b) LOW levels of transformational parenting (consistent LOW TP), and (c) inconsistent levels of transformational parenting (inconsistent HIGH-LOW TP). Results revealed that adolescents' perceptions of family transformational parenting were associated with both healthy dietary intake and physical activity. Adolescents who perceived their families to display the highest levels of transformational parenting (HIGH TP group) displayed greater healthy eating and physical activity behaviors than adolescents who perceived their families to display the lowest levels of transformational parenting behaviors (LOW TP group). Adolescents who perceived their families to display inconsistent levels of transformational parenting behaviors (HIGH-LOW TP group) displayed the same levels of healthy eating behaviors as those adolescents from the LOW TP group. For physical activity behaviors, adolescents who perceived their families to display inconsistent levels of transformational parenting behaviors (HIGH-LOW TP group) did not differ in terms of physical activity than those in either the HIGH TP or LOW TP group. Family transformational parenting behaviors were positively associated with both healthful dietary intake and leisure-time physical activity levels amongst adolescents. The findings suggest that transformational leadership theory is a useful framework for understanding the relationship between family leadership behaviors and adolescent health outcomes.
COTS displays applied to cockpit avionics applications
NASA Astrophysics Data System (ADS)
Thomas, J.; Lorimer, S.
2007-04-01
Avionics displays, particularly for cockpit applications are associated with high performance and high cost solutions. COTS displays have well acknowledged limitations but provide a potential high value for money solution if this performance can be stretched to a level compatible with "fit for use". This paper will describe the initial design tradeoffs and decisions that formed the basis for development of a low-cost cockpit display for a military helicopter.
Social Capital and Economic Development in Regional Australia: A Case Study
ERIC Educational Resources Information Center
Woodhouse, Andrew
2006-01-01
This article reports the findings of a case study of social capital and economic development conducted in two towns in regional Australia between 2001 and 2002. The hypothesis driving the research states that a town displaying a high level of social capital will also display a high level of economic development, while a town with a low level of…
ERIC Educational Resources Information Center
Loughlin, Catherine E.; Ivener, Bonnie L.
A study of patterns of literacy behaviors in high level literacy environments with varying levels of access to the environment began with a study of the instruments involved. Goals were to: (1) examine the reliability of the Survey of Displayed Literacy Stimuli; (2) study the correlation between scores from the Survey of Displayed Literacy Stimuli…
Miniaturized LEDs for flat-panel displays
NASA Astrophysics Data System (ADS)
Radauscher, Erich J.; Meitl, Matthew; Prevatte, Carl; Bonafede, Salvatore; Rotzoll, Robert; Gomez, David; Moore, Tanya; Raymond, Brook; Cok, Ronald; Fecioru, Alin; Trindade, António Jose; Fisher, Brent; Goodwin, Scott; Hines, Paul; Melnik, George; Barnhill, Sam; Bower, Christopher A.
2017-02-01
Inorganic light emitting diodes (LEDs) serve as bright pixel-level emitters in displays, from indoor/outdoor video walls with pixel sizes ranging from one to thirty millimeters to micro displays with more than one thousand pixels per inch. Pixel sizes that fall between those ranges, roughly 50 to 500 microns, are some of the most commercially significant ones, including flat panel displays used in smart phones, tablets, and televisions. Flat panel displays that use inorganic LEDs as pixel level emitters (μILED displays) can offer levels of brightness, transparency, and functionality that are difficult to achieve with other flat panel technologies. Cost-effective production of μILED displays requires techniques for precisely arranging sparse arrays of extremely miniaturized devices on a panel substrate, such as transfer printing with an elastomer stamp. Here we present lab-scale demonstrations of transfer printed μILED displays and the processes used to make them. Demonstrations include passive matrix μILED displays that use conventional off-the shelf drive ASICs and active matrix μILED displays that use miniaturized pixel-level control circuits from CMOS wafers. We present a discussion of key considerations in the design and fabrication of highly miniaturized emitters for μILED displays.
NASA Technical Reports Server (NTRS)
Post, R. B.; Welch, R. B.
1996-01-01
Visually perceived eye level (VPEL) was measured while subjects viewed two vertical lines which were either upright or pitched about the horizontal axis. In separate conditions, the display consisted of a relatively large pair of lines viewed at a distance of 1 m, or a display scaled to one third the dimensions and viewed at a distance of either 1 m or 33.3 cm. The small display viewed at 33.3 cm produced a retinal image the same size as that of the large display at 1 m. Pitch of all three displays top-toward and top-away from the observer caused upward and downward VPEL shifts, respectively. These effects were highly similar for the large display and the small display viewed at 33.3 cm (ie equal retinal size), but were significantly smaller for the small display viewed at 1 m. In a second experiment, perceived size of the three displays was measured and found to be highly accurate. The results of the two experiments indicate that the effect of optical pitch on VPEL depends on the retinal image size of stimuli rather than on perceived size.
Pouplin, Samuel; Roche, Nicolas; Vaugier, Isabelle; Jacob, Antoine; Figere, Marjorie; Pottier, Sandra; Antoine, Jean-Yves; Bensmail, Djamel
2016-02-01
To determine whether the number of words displayed in the word prediction software (WPS) list affects text input speed (TIS) in people with cervical spinal cord injury (SCI), and whether any influence is dependent on the level of the lesion. A cross-sectional trial. A rehabilitation center. Persons with cervical SCI (N=45). Lesion level was high (C4 and C5, American Spinal Injury Association [ASIA] grade A or B) for 15 participants (high-lesion group) and low (between C6 and C8, ASIA grade A or B) for 30 participants (low-lesion group). TIS was evaluated during four 10-minute copying tasks: (1) without WPS (Without); (2) with a display of 3 predicted words (3Words); (3) with a display of 6 predicted words (6Words); and (4) with a display of 8 predicted words (8Words). During the 4 copying tasks, TIS was measured objectively (characters per minute, number of errors) and subjectively through subject report (fatigue, perception of speed, cognitive load, satisfaction). For participants with low-cervical SCI, TIS without WPS was faster than with WPS, regardless of the number of words displayed (P<.001). For participants with high-cervical SCI, the use of WPS did not influence TIS (P=.99). There was no influence of the number of words displayed in a word prediction list on TIS; however, perception of TIS differed according to lesion level. For persons with low-cervical SCI, a small number of words should be displayed, or WPS should not be used at all. For persons with high-cervical SCI, a larger number of words displayed increases the comfort of use of WPS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Synthetic vision display evaluation studies
NASA Technical Reports Server (NTRS)
Regal, David M.; Whittington, David H.
1994-01-01
The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.
Design of the control system for full-color LED display based on MSP430 MCU
NASA Astrophysics Data System (ADS)
Li, Xue; Xu, Hui-juan; Qin, Ling-ling; Zheng, Long-jiang
2013-08-01
The LED display incorporate the micro electronic technique, computer technology and information processing as a whole, it becomes the most preponderant of a new generation of display media with the advantages of bright in color, high dynamic range, high brightness and long operating life, etc. The LED display has been widely used in the bank, securities trading, highway signs, airport and advertising, etc. According to the display color, the LED display screen is divided into monochrome screen, double color display and full color display. With the diversification of the LED display's color and the ceaseless rise of the display demands, the LED display's drive circuit and control technology also get the corresponding progress and development. The earliest monochrome screen just displaying Chinese characters, simple character or digital, so the requirements of the controller are relatively low. With the widely used of the double color LED display, the performance of its controller will also increase. In recent years, the full color LED display with three primary colors of red, green, blue and grayscale display effect has been highly attention with its rich and colorful display effect. Every true color pixel includes three son pixels of red, green, blue, using the space colour mixture to realize the multicolor. The dynamic scanning control system of LED full-color display is designed based on MSP430 microcontroller technology of the low power consumption. The gray control technology of this system used the new method of pulse width modulation (PWM) and 19 games show principle are combining. This method in meet 256 level grayscale display conditions, improves the efficiency of the LED light device, and enhances the administrative levels feels of the image. Drive circuit used 1/8 scanning constant current drive mode, and make full use of the single chip microcomputer I/O mouth resources to complete the control. The system supports text, pictures display of 256 grayscale full-color LED screen.
Anion control as a strategy to achieve high-mobility and high-stability oxide thin-film transistors.
Kim, Hyun-Suk; Jeon, Sang Ho; Park, Joon Seok; Kim, Tae Sang; Son, Kyoung Seok; Seon, Jong-Baek; Seo, Seok-Jun; Kim, Sun-Jae; Lee, Eunha; Chung, Jae Gwan; Lee, Hyungik; Han, Seungwu; Ryu, Myungkwan; Lee, Sang Yoon; Kim, Kinam
2013-01-01
Ultra-definition, large-area displays with three-dimensional visual effects represent megatrend in the current/future display industry. On the hardware level, such a "dream" display requires faster pixel switching and higher driving current, which in turn necessitate thin-film transistors (TFTs) with high mobility. Amorphous oxide semiconductors (AOS) such as In-Ga-Zn-O are poised to enable such TFTs, but the trade-off between device performance and stability under illumination critically limits their usability, which is related to the hampered electron-hole recombination caused by the oxygen vacancies. Here we have improved the illumination stability by substituting oxygen with nitrogen in ZnO, which may deactivate oxygen vacancies by raising valence bands above the defect levels. Indeed, the stability under illumination and electrical bias is superior to that of previous AOS-based TFTs. By achieving both mobility and stability, it is highly expected that the present ZnON TFTs will be extensively deployed in next-generation flat-panel displays.
Anion control as a strategy to achieve high-mobility and high-stability oxide thin-film transistors
Kim, Hyun-Suk; Jeon, Sang Ho; Park, Joon Seok; Kim, Tae Sang; Son, Kyoung Seok; Seon, Jong-Baek; Seo, Seok-Jun; Kim, Sun-Jae; Lee, Eunha; Chung, Jae Gwan; Lee, Hyungik; Han, Seungwu; Ryu, Myungkwan; Lee, Sang Yoon; Kim, Kinam
2013-01-01
Ultra-definition, large-area displays with three-dimensional visual effects represent megatrend in the current/future display industry. On the hardware level, such a “dream” display requires faster pixel switching and higher driving current, which in turn necessitate thin-film transistors (TFTs) with high mobility. Amorphous oxide semiconductors (AOS) such as In-Ga-Zn-O are poised to enable such TFTs, but the trade-off between device performance and stability under illumination critically limits their usability, which is related to the hampered electron-hole recombination caused by the oxygen vacancies. Here we have improved the illumination stability by substituting oxygen with nitrogen in ZnO, which may deactivate oxygen vacancies by raising valence bands above the defect levels. Indeed, the stability under illumination and electrical bias is superior to that of previous AOS-based TFTs. By achieving both mobility and stability, it is highly expected that the present ZnON TFTs will be extensively deployed in next-generation flat-panel displays. PMID:23492854
Evaluation of an organic light-emitting diode display for precise visual stimulation.
Ito, Hiroyuki; Ogawa, Masaki; Sunaga, Shoji
2013-06-11
A new type of visual display for presentation of a visual stimulus with high quality was assessed. The characteristics of an organic light-emitting diode (OLED) display (Sony PVM-2541, 24.5 in.; Sony Corporation, Tokyo, Japan) were measured in detail from the viewpoint of its applicability to visual psychophysics. We found the new display to be superior to other display types in terms of spatial uniformity, color gamut, and contrast ratio. Changes in the intensity of luminance were sharper on the OLED display than those on a liquid crystal display. Therefore, such OLED displays could replace conventional cathode ray tube displays in vision research for high quality stimulus presentation. Benefits of using OLED displays in vision research were especially apparent in the fields of low-level vision, where precise control and description of the stimulus are needed, e.g., in mesopic or scotopic vision, color vision, and motion perception.
Cross-cultural evidence that the nonverbal expression of pride is an automatic status signal.
Tracy, Jessica L; Shariff, Azim F; Zhao, Wanying; Henrich, Joseph
2013-02-01
To test whether the pride expression is an implicit, reliably developing signal of high social status in humans, the authors conducted a series of experiments that measured implicit and explicit cognitive associations between pride displays and high-status concepts in two culturally disparate populations--North American undergraduates and Fijian villagers living in a traditional, small-scale society. In both groups, pride displays produced strong implicit associations with high status, despite Fijian social norms discouraging overt displays of pride. Also in both groups, implicit and explicit associations between emotion expressions and status were dissociated; despite the cross-cultural implicit association between pride displays and high status, happy displays were, cross-culturally, the more powerful status indicator at an explicit level, and among Fijians, happy and pride displays were equally strongly implicitly associated with status. Finally, a cultural difference emerged: Fijians viewed happy displays as more deserving of high status than did North Americans, both implicitly and explicitly. Together, these findings suggest that the display and recognition of pride may be part of a suite of adaptations for negotiating status relationships, but that the high-status message of pride is largely communicated through implicit cognitive processes. 2013 APA, all rights reserved
Resconi, Virginia Celia; Escudero, Ana; Beltrán, José Antonio; Olleta, José Luis; Sañudo, Carlos; Campo, María del Mar
2012-01-01
High oxygen modified atmosphere packaging (MAP) is currently used by the industry to maintain an attractive color in fresh meat. However, it can also promote lipid oxidation and sensory changes. The aim of this study was to compare the quality of beef steaks displayed under different levels of oxygen. For that purpose, meat was stored with 50%, 60%, and 80% of oxygen for 4 and 8 d at retail conditions. A control treatment with steaks vacuum packaged, without exposure to retail display, was included, and color, lipid oxidation, organoleptic characteristics, and aroma compounds were analyzed. Steaks displayed under high oxygen MAP with 50% of oxygen showed the lowest color stability, according to hue values. Higher oxygen levels did not necessarily correspond with higher rancidity levels in the raw meat. Thiobarbituric Acid Reacting Substances (TBARS) values were higher than 2.2 mg malonaldehyde (MDA)/kg muscle in all the samples displayed for 8 d at retail conditions. These samples exhibited the highest intensities of rancid and the least intense beef odors and flavors. The ketones: 2,3-butanedione, 2-octanone, 2,3-pentanedione, 2-heptanone, 4-methyl-2-pentanone, and the aldehydes: pentanal, 2-methyl-butanal, and 2-furfurylthiol, 1-octen-3-ol and 2-methylpropyl-acetate, were proposed as candidates for the aroma differences between the cooked beef steaks stored under vacuum and high oxygen packs. High oxygen modified atmosphere packaging (MAP) is used to increase shelf-life and color at the retail level. However, oxygen deteriorates faster some quality attributes, being a contributor to lipid oxidation that could be perceived at consumption. This study attempts to find the best gas composition in a MAP in order to maintain the color, minimizing the oxidation. Aromatically relevant chemicals have been analyzed by gas olfactometry-gas chromatography as a key to measure beef oxidation after display. © 2011 Institute of Food Technologists®
Design and test of a situation-augmented display for an unmanned aerial vehicle monitoring task.
Lu, Jen-Li; Horng, Ruey-Yun; Chao, Chin-Jung
2013-08-01
In this study, a situation-augmented display for unmanned aerial vehicle (UAV) monitoring was designed, and its effects on operator performance and mental workload were examined. The display design was augmented with the knowledge that there is an invariant flight trajectory (formed by the relationship between altitude and velocity) for every flight, from takeoff to landing. 56 participants were randomly assigned to the situation-augmented display or a conventional display condition to work on 4 (number of abnormalities) x 2 (noise level) UAV monitoring tasks three times. Results showed that the effects of situation-augmented display on flight completion time and time to detect abnormalities were robust under various workload conditions, but error rate and perceived mental workload were unaffected by the display type. Results suggest that the UAV monitoring task is extremely difficult, and that display devices providing high-level situation-awareness may improve operator monitoring performance.
Using high-resolution displays for high-resolution cardiac data.
Goodyer, Christopher; Hodrien, John; Wood, Jason; Kohl, Peter; Brodlie, Ken
2009-07-13
The ability to perform fast, accurate, high-resolution visualization is fundamental to improving our understanding of anatomical data. As the volumes of data increase from improvements in scanning technology, the methods applied to visualization must evolve. In this paper, we address the interactive display of data from high-resolution magnetic resonance imaging scanning of a rabbit heart and subsequent histological imaging. We describe a visualization environment involving a tiled liquid crystal display panel display wall and associated software, which provides an interactive and intuitive user interface. The oView software is an OpenGL application that is written for the VR Juggler environment. This environment abstracts displays and devices away from the application itself, aiding portability between different systems, from desktop PCs to multi-tiled display walls. Portability between display walls has been demonstrated through its use on walls at the universities of both Leeds and Oxford. We discuss important factors to be considered for interactive two-dimensional display of large three-dimensional datasets, including the use of intuitive input devices and level of detail aspects.
Hierarchical tone mapping for high dynamic range image visualization
NASA Astrophysics Data System (ADS)
Qiu, Guoping; Duan, Jiang
2005-07-01
In this paper, we present a computationally efficient, practically easy to use tone mapping techniques for the visualization of high dynamic range (HDR) images in low dynamic range (LDR) reproduction devices. The new method, termed hierarchical nonlinear linear (HNL) tone-mapping operator maps the pixels in two hierarchical steps. The first step allocates appropriate numbers of LDR display levels to different HDR intensity intervals according to the pixel densities of the intervals. The second step linearly maps the HDR intensity intervals to theirs allocated LDR display levels. In the developed HNL scheme, the assignment of LDR display levels to HDR intensity intervals is controlled by a very simple and flexible formula with a single adjustable parameter. We also show that our new operators can be used for the effective enhancement of ordinary images.
NASA Astrophysics Data System (ADS)
Gong, Rui; Xu, Haisong; Wang, Binyu; Luo, Ming Ronnier
2012-08-01
The image quality of two active matrix organic light emitting diode (AMOLED) smart-phone displays and two in-plane switching (IPS) ones was visually assessed at two levels of ambient lighting conditions corresponding to indoor and outdoor applications, respectively. Naturalness, colorfulness, brightness, contrast, sharpness, and overall image quality were evaluated via psychophysical experiment by categorical judgment method using test images selected from different application categories. The experimental results show that the AMOLED displays perform better on colorfulness because of their wide color gamut, while the high pixel resolution and high peak luminance of the IPS panels help the perception of brightness, contrast, and sharpness. Further statistical analysis of ANOVA indicates that ambient lighting levels have significant influences on the attributes of brightness and contrast.
Vervoort, Tine; Caes, Line; Crombez, Geert; Koster, Ernst; Van Damme, Stefaan; Dewitte, Marieke; Goubert, Liesbet
2011-08-01
The attentional demand of pain has primarily been investigated within an intrapersonal context. Little is known about observers' attentional processing of another's pain. The present study investigated, within a sample of parents (n=65; 51 mothers, 14 fathers) of school children, parental selective attention to children's facial display of pain and the moderating role of child's facial expressiveness of pain and parental catastrophizing about their child's pain. Parents performed a dot-probe task in which child facial display of pain (of varying pain expressiveness) were presented. Findings provided evidence of parental selective attention to child pain displays. Low facial displays of pain appeared sufficiently and also, as compared with higher facial displays of pain, equally capable of engaging parents' attention to the location of threat. Severity of facial displays of pain had a nonspatial effect on attention; that is, there was increased interference (ie, delayed responding) with increasing facial expressiveness. This interference effect was particularly pronounced for high-catastrophizing parents, suggesting that being confronted with increasing child pain displays becomes particularly demanding for high-catastrophizing parents. Finally, parents with higher levels of catastrophizing increasingly attended away from low pain expressions, whereas selective attention to high-pain expressions did not differ between high-catastrophizing and low-catastrophizing parents. Theoretical implications and further research directions are discussed. Copyright © 2011 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Kim, Jee; Topolski, Richard; Dickinson, Douglas; Ramos, Van
2017-09-01
Information is lacking for viewer preferences for incisal display with lips in repose. The purpose of this online survey was to establish measurement parameters to classify and define a lip form and to evaluate the influence of lip form on dentists' and laypersons' preferences for the amount of incisal display with lips in repose. Computer-generated male and female models were created using 3 different lip forms each, straight, moderate, and high. Three images of these models (frontal full face, zoomed-in frontal around the mouth, and oblique zoomed-in image of the mouth) were arranged in an interactive survey that was disseminated on the Websites Facebook, Instagram, DentalTown and by word-of-mouth. Respondents manipulated the incisal display of all 3 images in unison, using a slide bar, and the resulting incisal display was measured in millimeters and served as the primary dependent measure. Survey demographic data were obtained from an online survey site. Data were assessed for skewness, kurtosis, and outliers and analyzed with 5-way ANOVA: 2 sex levels for model, 2 levels for sex of respondent, 3 levels for lip height, 3 levels for occupation, and 5 levels of ethnicity, with multiple comparisons corrected with Bonferroni adjustments and post hoc comparisons performed using the Scheffé test (α=.05 for all comparisons). A total of 1039 individuals consented to the study. A final sample size of 687 respondents was obtained after excluding 352 who failed to complete the survey. The results indicated that lip form affected the esthetic perception of incisal display significantly (P<.001), with a preference for a greater amount of incisal display corresponding with increasing lip forms. Sex of the model was also significant, with greater incisal display being preferred for female faces. A significant difference was found for respondents' ethnicity, with African Americans generally preferring smaller incisal displays than other ethnic groups. No other main effects were found to be statistically significant. Only 2 interactions were shown to be statistically significant. Post hoc tests examining the interaction between lip form and sex of model showed a preference for greater incisal displays for female faces with high lip forms. A 3-way interaction was observed between lip form, sex of respondent, and occupation. Significant differences were identified for the 3 different lip forms for both sexes of models. As the lip form changed from straight to moderate to high, there was a preference for increased incisal display. Incisal display preferences for male and female models were the same for all respondents, except for the high lip form, for which a greater amount of incisal display was preferred for the female model. Sex and occupation of respondent failed to produce main effects. Respondents' ethnicity was shown to be statistically significant, with African Americans generally preferring shorter incisal displays. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
MYST: a comprehensive high-level AO control tool for GeMS
NASA Astrophysics Data System (ADS)
Rigaut, F.; Neichel, B.; Bec, M.; Garcia-Rissman, A.
2010-07-01
Myst is the Gemini MCAO System (GeMS) high level control GUI. It is written in yorick, python and C. In this paper, we review the software architecture of Myst and its primary purposes, which are many: Real-time display, high level diagnostics, calibrations, and executor/sequencer of high level actions (closing the loop, coordinating dithers, etc).
X-Windows Widget for Image Display
NASA Technical Reports Server (NTRS)
Deen, Robert G.
2011-01-01
XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.
Prado, I N; Campo, M M; Muela, E; Valero, M V; Catalan, O; Olleta, J L; Sañudo, C
2015-08-01
A total of 64 intensively reared Friesian steers were used in a 2×2×2 design to study the effects of age of castration (15 days old v. 5 months old), dietary protein level (14.6% v. 16.8%; DM basis) and lysine/methionine (lys/met) ratio (3.0 v. 3.4) on meat quality. The lys/met ratio of 3.0 was reached with supplementation of protected methionine. Animals were slaughtered at a live weight of 443.5 ± 26.2 kg at around 12 months of age. Colour and lipid oxidation were measured in the longissimus thoracis muscle throughout the 14 days of display under modified atmospheric and commercial display conditions. A panel of 17 consumers assessed daily the visual acceptability of the meat on display. A consumer acceptability eating test was also performed with 120 consumers in meat aged for 7 days under vacuum conditions. Lipid oxidation was not influenced by castration age and the protein level in the diet. Castration age did not affect meat colour, but meat from the low protein level diet and the low lys/met ratio showed higher redness (a*) from 3 days of display onwards. Nevertheless, from 6 days onwards, consumer visual acceptability was below the level of acceptance in all treatments, and even from 5 days onwards in those animals that underwent early castration and were fed either a high protein diet or a combination diet low in protein content and high in lys/met ratio. The best accepted treatments throughout the display period were those from late castrated animals fed a low protein diet, probably related to other visual aspects. However, the best accepted meat after consumption was that from late castrated animals fed high protein and high lys/met. The addition of protected methionine to reach lys/met levels of 3.0 did not improve beef acceptability, with the high protein diet being preferred by consumers in terms of palatability in late castrated animals.
Interactive Display of High-Resolution Images on the World Wide Web.
ERIC Educational Resources Information Center
Clyde, Stephen W.; Hirschi, Gregory W.
Viewing high-resolution images on the World Wide Web at a level of detail necessary for collaborative research is still a problem today, given the Internet's current bandwidth limitations and its ever increasing network traffic. ImageEyes is an interactive display tool being developed at Utah State University that addresses this problem by…
Thornton, Lukar E; Cameron, Adrian J; McNaughton, Sarah A; Worsley, Anthony; Crawford, David A
2012-03-15
Supermarkets play a major role in influencing the food purchasing behaviours of most households. Snack food exposures within these stores may contribute to higher levels of consumption and ultimately to increasing levels of obesity, particularly within socioeconomically disadvantaged neighbourhoods. We aimed to examine the availability of snack food displays at checkouts, end-of-aisle displays and island displays in major supermarket chains in the least and most socioeconomically disadvantaged neighbourhoods of Melbourne. Within-store audits of 35 Melbourne supermarkets. Supermarkets were sampled from the least and most socioeconomically disadvantaged suburbs within 30 km of the Melbourne CBD. We measured the availability of crisps, chocolate, confectionery, and soft drinks (diet and regular) at the checkouts, in end-of-aisle displays, and in island bin displays. Snack food displays were most prominent at checkouts with only five stores not having snack foods at 100% of their checkouts. Snack foods were also present at a number of end-of-aisle displays (at both the front (median 38%) and back (median 33%) of store), and in island bin displays (median number of island displays: 7; median total circumference of island displays: 19.4 metres). Chocolate items were the most common snack food item on display. There was no difference in the availability of these snack food displays by neighbourhood disadvantage. As a result of the high availability of snack food displays, exposure to snack foods is almost unavoidable in Melbourne supermarkets, regardless of levels of neighbourhood socioeconomic disadvantage. Results of this study could promote awareness of the prominence of unhealthy food items in chain-brand supermarkets outlets.
A novel emissive projection display (EPD) on transparent phosphor screen
NASA Astrophysics Data System (ADS)
Cheng, Botao; Sun, Leonard; Yu, Ge; Sun, Ted X.
2017-03-01
A new paradigm of digital projection is on the horizon, based on innovative emissive screen that are made fully transparent. It can be readily applied and convert any surface to a high image quality emissive digital display, without affecting the surface appearance. For example, it can convert any glass window or windshield to completely see-through display, with unlimited field of view and viewing angles. It also enables a scalable and economic projection display on a pitch-black emissive screen with black level and image contrast that rivals other emissive displays such as plasma display or OLED.
Baldwin, Carryl L; Struckman-Johnson, David
2002-01-15
Speech displays and verbal response technologies are increasingly being used in complex, high workload environments that require the simultaneous performance of visual and manual tasks. Examples of such environments include the flight decks of modern aircraft, advanced transport telematics systems providing invehicle route guidance and navigational information and mobile communication equipment in emergency and public safety vehicles. Previous research has established an optimum range for speech intelligibility. However, the potential for variations in presentation levels within this range to affect attentional resources and cognitive processing of speech material has not been examined previously. Results of the current experimental investigation demonstrate that as presentation level increases within this 'optimum' range, participants in high workload situations make fewer sentence-processing errors and generally respond faster. Processing errors were more sensitive to changes in presentation level than were measures of reaction time. Implications of these findings are discussed in terms of their application for the design of speech communications displays in complex multi-task environments.
Validity and Reliability Analysis for the Teacher Determination for Democratic Behavior Scale
ERIC Educational Resources Information Center
Yesil, Rustu
2010-01-01
The main aim of this study is to develop a scale to assess the extent to which teachers display democratic behaviors they are supposed to display in in-classroom teaching practices and the level of their determination in displaying such behaviors. The study group of this survey is composed of 446 second grade high school students, 243 girls and…
Morris, E Matthew; Meers, Grace M E; Koch, Lauren G; Britton, Steven L; Fletcher, Justin A; Fu, Xiaorong; Shankar, Kartik; Burgess, Shawn C; Ibdah, Jamal A; Rector, R Scott; Thyfault, John P
2016-10-01
Rats selectively bred for high capacity running (HCR) or low capacity running (LCR) display divergence for intrinsic aerobic capacity and hepatic mitochondrial oxidative capacity, both factors associated with susceptibility for nonalcoholic fatty liver disease. Here, we tested if HCR and LCR rats display differences in susceptibility for hepatic steatosis after 16 wk of high-fat diets (HFD) with either 45% or 60% of kcals from fat. HCR rats were protected against HFD-induced hepatic steatosis, whereas only the 60% HFD induced steatosis in LCR rats, as marked by a doubling of liver triglycerides. Hepatic complete fatty acid oxidation (FAO) and mitochondrial respiratory capacity were all lower in LCR compared with HCR rats. LCR rats also displayed lower hepatic complete and incomplete FAO in the presence of etomoxir, suggesting a reduced role for noncarnitine palmitoyltransferase-1-mediated lipid catabolism in LCR versus HCR rats. Hepatic complete FAO and mitochondrial respiration were largely unaffected by either chronic HFD; however, 60% HFD feeding markedly reduced 2-pyruvate oxidation, a marker of tricarboxylic acid (TCA) cycle flux, and mitochondrial complete FAO only in LCR rats. LCR rats displayed lower levels of hepatic long-chain acylcarnitines than HCR rats but maintained similar levels of hepatic acetyl-carnitine levels, further supporting lower rates of β-oxidation, and TCA cycle flux in LCR than HCR rats. Finally, only LCR rats displayed early reductions in TCA cycle genes after the acute initiation of a HFD. In conclusion, intrinsically high aerobic capacity confers protection against HFD-induced hepatic steatosis through elevated hepatic mitochondrial oxidative capacity.
Morris, E. Matthew; Meers, Grace M. E.; Koch, Lauren G.; Britton, Steven L.; Fletcher, Justin A.; Fu, Xiaorong; Shankar, Kartik; Burgess, Shawn C.; Ibdah, Jamal A.; Rector, R. Scott
2016-01-01
Rats selectively bred for high capacity running (HCR) or low capacity running (LCR) display divergence for intrinsic aerobic capacity and hepatic mitochondrial oxidative capacity, both factors associated with susceptibility for nonalcoholic fatty liver disease. Here, we tested if HCR and LCR rats display differences in susceptibility for hepatic steatosis after 16 wk of high-fat diets (HFD) with either 45% or 60% of kcals from fat. HCR rats were protected against HFD-induced hepatic steatosis, whereas only the 60% HFD induced steatosis in LCR rats, as marked by a doubling of liver triglycerides. Hepatic complete fatty acid oxidation (FAO) and mitochondrial respiratory capacity were all lower in LCR compared with HCR rats. LCR rats also displayed lower hepatic complete and incomplete FAO in the presence of etomoxir, suggesting a reduced role for noncarnitine palmitoyltransferase-1-mediated lipid catabolism in LCR versus HCR rats. Hepatic complete FAO and mitochondrial respiration were largely unaffected by either chronic HFD; however, 60% HFD feeding markedly reduced 2-pyruvate oxidation, a marker of tricarboxylic acid (TCA) cycle flux, and mitochondrial complete FAO only in LCR rats. LCR rats displayed lower levels of hepatic long-chain acylcarnitines than HCR rats but maintained similar levels of hepatic acetyl-carnitine levels, further supporting lower rates of β-oxidation, and TCA cycle flux in LCR than HCR rats. Finally, only LCR rats displayed early reductions in TCA cycle genes after the acute initiation of a HFD. In conclusion, intrinsically high aerobic capacity confers protection against HFD-induced hepatic steatosis through elevated hepatic mitochondrial oxidative capacity. PMID:27600823
Individual consistency in exploratory behaviour and mating tactics in male guppies
NASA Astrophysics Data System (ADS)
Kelley, Jennifer L.; Phillips, Samuel C.; Evans, Jonathan P.
2013-10-01
While behavioural plasticity is considered an adaptation to fluctuating social and environmental conditions, many animals also display a high level of individual consistency in their behaviour over time or across contexts (generally termed ‘personality’). However, studies of animal personalities that include sexual behaviour, or functionally distinct but correlated traits, are relatively scarce. In this study, we tested for individual behavioural consistency in courtship and exploratory behaviour in male guppies ( Poecilia reticulata) in two light environments (high vs. low light intensity). Based on previous work on guppies, we predicted that males would modify their behaviour from sneak mating tactics to courtship displays under low light conditions, but also that the rank orders of courtship effort would remain unchanged (i.e. highly sexually active individuals would display relatively high levels of courtship under both light regimes). We also tested for correlations between courtship and exploratory behaviour, predicting that males that had high display rates would also be more likely to approach a novel object. Although males showed significant consistency in their exploratory and mating behaviour over time (1 week), we found no evidence that these traits constituted a behavioural syndrome. Furthermore, in contrast to previous work, we found no overall effect of the light environment on any of the behaviours measured, although males responded to the treatment on an individual-level basis, as reflected by a significant individual-by-environment interaction. The future challenge is to investigate how individual consistency across different environmental contexts relates to male reproductive success.
NASA Technical Reports Server (NTRS)
Edmonds, Karina
2008-01-01
This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.
The availability of snack food displays that may trigger impulse purchases in Melbourne supermarkets
2012-01-01
Background Supermarkets play a major role in influencing the food purchasing behaviours of most households. Snack food exposures within these stores may contribute to higher levels of consumption and ultimately to increasing levels of obesity, particularly within socioeconomically disadvantaged neighbourhoods. We aimed to examine the availability of snack food displays at checkouts, end-of-aisle displays and island displays in major supermarket chains in the least and most socioeconomically disadvantaged neighbourhoods of Melbourne. Methods Within-store audits of 35 Melbourne supermarkets. Supermarkets were sampled from the least and most socioeconomically disadvantaged suburbs within 30 km of the Melbourne CBD. We measured the availability of crisps, chocolate, confectionery, and soft drinks (diet and regular) at the checkouts, in end-of-aisle displays, and in island bin displays. Results Snack food displays were most prominent at checkouts with only five stores not having snack foods at 100% of their checkouts. Snack foods were also present at a number of end-of-aisle displays (at both the front (median 38%) and back (median 33%) of store), and in island bin displays (median number of island displays: 7; median total circumference of island displays: 19.4 metres). Chocolate items were the most common snack food item on display. There was no difference in the availability of these snack food displays by neighbourhood disadvantage. Conclusions As a result of the high availability of snack food displays, exposure to snack foods is almost unavoidable in Melbourne supermarkets, regardless of levels of neighbourhood socioeconomic disadvantage. Results of this study could promote awareness of the prominence of unhealthy food items in chain-brand supermarkets outlets. PMID:22420759
ERIC Educational Resources Information Center
Barden-Gabbei, Laura M.
2006-01-01
The overhead projector is an excellent tool for teachers at both the high school and college level. Teachers often use it to display class notes as they monitor students' actions and reactions to the concepts being presented and discussed, to display diagrams and figures too complex to draw on the chalkboard, and more recently to display computer…
Display activity and seasonality of faecal sexual steroids in male great bustard (Otis tarda L.).
Biczó, A; Péczely, P
2007-03-01
The non-invasive faecal sampling and RIA was used to measure faecal equivalents of testosterone (T), dehydroepiandrosterone (DHEA), oestradiol-17beta (E2) and progesterone (P4) in juvenile and adult great bustard males. Possible connections of diurnal and seasonal changes of sexual steroid levels and display activity were studied. Correlations were found between sexual steroid equivalent levels of faeces and display activity and agonistic behaviour in the different phases of annual cycle of adult males. In early display period increasing levels of androgens were measured, during main display period very high androgen dominance was observable against E2 and P4. During postnuptial moult strong T decrease and DHEA and P4 increase were detected. Elevation of E2 was measured during wintering. In juveniles level of DHEA was higher than level of T suggesting its importance in immature males. Decrease of T was detected between reproductive period and postnuptial moult and DHEA between reproduction and wintering, accompanying with E2 elevation. The inhibiting effect of inclement weather on gonad functions also was detected in our study. We suppose that the unexpected cold weather with strong wind depressed the levels of androgens both in juveniles and adults and the increase of faecal E2 was also detected.
Advances in Proteomics Data Analysis and Display Using an Accurate Mass and Time Tag Approach
Zimmer, Jennifer S.D.; Monroe, Matthew E.; Qian, Wei-Jun; Smith, Richard D.
2007-01-01
Proteomics has recently demonstrated utility in understanding cellular processes on the molecular level as a component of systems biology approaches and for identifying potential biomarkers of various disease states. The large amount of data generated by utilizing high efficiency (e.g., chromatographic) separations coupled to high mass accuracy mass spectrometry for high-throughput proteomics analyses presents challenges related to data processing, analysis, and display. This review focuses on recent advances in nanoLC-FTICR-MS-based proteomics approaches and the accompanying data processing tools that have been developed to display and interpret the large volumes of data being produced. PMID:16429408
Blubaugh, Morgan V.; Uslan, Mark M.
2012-01-01
The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, full-functionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39–1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55–96% and font height ranging 0.28–0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. PMID:22538132
Blubaugh, Morgan V; Uslan, Mark M
2012-03-01
The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, fullfunctionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39-1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55-96% and font height ranging 0.28-0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. © 2012 Diabetes Technology Society.
Object-based warping: an illusory distortion of space within objects.
Vickery, Timothy J; Chun, Marvin M
2010-12-01
Visual objects are high-level primitives that are fundamental to numerous perceptual functions, such as guidance of attention. We report that objects warp visual perception of space in such a way that spatial distances within objects appear to be larger than spatial distances in ground regions. When two dots were placed inside a rectangular object, they appeared farther apart from one another than two dots with identical spacing outside of the object. To investigate whether this effect was object based, we measured the distortion while manipulating the structure surrounding the dots. Object displays were constructed with a single object, multiple objects, a partially occluded object, and an illusory object. Nonobject displays were constructed to be comparable to object displays in low-level visual attributes. In all cases, the object displays resulted in a more powerful distortion of spatial perception than comparable non-object-based displays. These results suggest that perception of space within objects is warped.
A multiresolution halftoning algorithm for progressive display
NASA Astrophysics Data System (ADS)
Mukherjee, Mithun; Sharma, Gaurav
2005-01-01
We describe and implement an algorithmic framework for memory efficient, 'on-the-fly' halftoning in a progressive transmission environment. Instead of a conventional approach which repeatedly recalls the continuous tone image from memory and subsequently halftones it for display, the proposed method achieves significant memory efficiency by storing only the halftoned image and updating it in response to additional information received through progressive transmission. Thus the method requires only a single frame-buffer of bits for storage of the displayed binary image and no additional storage is required for the contone data. The additional image data received through progressive transmission is accommodated through in-place updates of the buffer. The method is thus particularly advantageous for high resolution bi-level displays where it can result in significant savings in memory. The proposed framework is implemented using a suitable multi-resolution, multi-level modification of error diffusion that is motivated by the presence of a single binary frame-buffer. Aggregates of individual display bits constitute the multiple output levels at a given resolution. This creates a natural progression of increasing resolution with decreasing bit-depth.
Software Development for Remote Control and Firing Room Displays
NASA Technical Reports Server (NTRS)
Zambrano Pena, Jessica
2014-01-01
The Launch Control System (LCS) developed at NASA's Kennedy Space Center (KSC) will be used to launch future spacecraft. Two of the many components of this system are the Application Control Language (ACL) and remote displays. ACL is a high level domain specific language that is used to write remote control applications for LCS. Remote displays are graphical user interfaces (GUIs) developed to display vehicle and Ground Support Equipment (GSE) data, they also provide the ability to send commands to control GSE and the vehicle. The remote displays and the control applications have many facets and this internship experience dealt with several of them.
Nonlinear mapping of the luminance in dual-layer high dynamic range displays
NASA Astrophysics Data System (ADS)
Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi
2009-02-01
It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.
Kirkness, Catherine J; Burr, Robert L; Cain, Kevin C; Newell, David W; Mitchell, Pamela H
2008-01-01
Nurses' ability to rapidly detect decreases in cerebral perfusion pressure (CPP), which may contribute to secondary brain injury, may be limited by poor visibility of CPP displays. To evaluate the impact of a highly visible CPP display on the functional outcome in individuals with cerebral aneurysms. Patients with cerebral aneurysms (n = 100) who underwent continuous CPP monitoring were enrolled and randomized to beds with or without the additional CPP display. Six-month outcome was assessed. Functional outcome was not significantly different between control and intervention groups after controlling for initial neurologic condition (odds ratio .904, 95% confidence interval 0.317 to 2.573). However, greater time below CPP thresholds (55 to 70 mm Hg) was significantly associated with poorer outcome (P = .005 to .010). Although the enhanced CPP display was not associated with significantly better outcome, longer periods of CPP below set levels were associated with poorer outcome.
Atomized scan strategy for high definition for VR application
NASA Astrophysics Data System (ADS)
Huang, Shuping; Ran, Feng; Ji, Yuan; Chen, Wendong
2017-10-01
Silicon-based OLED (Organic Light Emitting Display) microdisplay technology begins to attract people's attention in the emerging VR and AR devices. The high display frame refresh rate is an important solution to alleviate the dizziness in VR applications. Traditional display circuit drivers use the analog method or the digital PWM method that follow the serial scan order from the first pixel to the last pixel by using the shift registers. This paper proposes a novel atomized scan strategy based on the digital fractal scan strategy using the pseudo-random scan order. It can be used to realize the high frame refresh rate with the moderate pixel clock frequency in the high definition OLED microdisplay. The linearity of the gray level is also improved compared with the Z fractal scan strategy.
Santos, Maria-José; Nogueira, José Rocha; Patarata, Luis; Mayan, Olga
2008-12-01
Food safety levels in school food services are an important concern, given that any incident can affect a high number of students. The purpose of this research was to evaluate food handlers' knowledge and self-reported behaviour as regards the safe handling of food in school canteens. The study was conducted in 32 school canteens and included 124 participants. Food handlers displayed a reasonable level of knowledge, particularly regarding personal hygiene and cross-contamination, but fared worse in other areas. The level of knowledge displayed was influenced by age, motivation and training. A high correctness in handlers' self-reported behaviour towards food safety was observed, with a negative trend appearing when workload was increased. Our assessment of prevailing knowledge levels indicates that food professionals need to be made significantly more aware of the importance their actions can have on children's health.
Information transfer rate with serial and simultaneous visual display formats
NASA Astrophysics Data System (ADS)
Matin, Ethel; Boff, Kenneth R.
1988-04-01
Information communication rate for a conventional display with three spatially separated windows was compared with rate for a serial display in which data frames were presented sequentially in one window. For both methods, each frame contained a randomly selected digit with various amounts of additional display 'clutter.' Subjects recalled the digits in a prescribed order. Large rate differences were found, with faster serial communication for all levels of the clutter factors. However, the rate difference was most pronounced for highly cluttered displays. An explanation for the latter effect in terms of visual masking in the retinal periphery was supported by the results of a second experiment. The working hypothesis that serial displays can speed information transfer for automatic but not for controlled processing is discussed.
Emotional display rules as work unit norms: a multilevel analysis of emotional labor among nurses.
Diefendorff, James M; Erickson, Rebecca J; Grandey, Alicia A; Dahling, Jason J
2011-04-01
Emotional labor theory has conceptualized emotional display rules as shared norms governing the expression of emotions at work. Using a sample of registered nurses working in different units of a hospital system, we provided the first empirical evidence that display rules can be represented as shared, unit-level beliefs. Additionally, controlling for the influence of dispositional affectivity, individual-level display rule perceptions, and emotion regulation, we found that unit-level display rules are associated with individual-level job satisfaction. We also showed that unit-level display rules relate to burnout indirectly through individual-level display rule perceptions and emotion regulation strategies. Finally, unit-level display rules also interacted with individual-level dispositional affectivity to predict employee use of emotion regulation strategies. We discuss how future research on emotional labor and display rules, particularly in the health care setting, can build on these findings.
Low Voltage, Low Power Organic Light Emitting Transistors for AMOLED Displays
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCarthy, M. A.; Liu, B.; Donoghue, E. P.
2011-01-01
Low voltage, low power dissipation, high aperture ratio organic light emitting transistors are demonstrated. The high level of performance is enabled by a carbon nanotube source electrode that permits integration of the drive transistor and the organic light emitting diode into an efficient single stacked device. Given the demonstrated performance, this technology could break the technical logjam holding back widespread deployment of active matrix organic light emitting displays at flat panel screen sizes.
Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan
2017-08-01
In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.
High level intelligent control of telerobotics systems
NASA Technical Reports Server (NTRS)
Mckee, James
1988-01-01
A high level robot command language is proposed for the autonomous mode of an advanced telerobotics system and a predictive display mechanism for the teleoperational model. It is believed that any such system will involve some mixture of these two modes, since, although artificial intelligence can facilitate significant autonomy, a system that can resort to teleoperation will always have the advantage. The high level command language will allow humans to give the robot instructions in a very natural manner. The robot will then analyze these instructions to infer meaning so that is can translate the task into lower level executable primitives. If, however, the robot is unable to perform the task autonomously, it will switch to the teleoperational mode. The time delay between control movement and actual robot movement has always been a problem in teleoperations. The remote operator may not actually see (via a monitor) the results of high actions for several seconds. A computer generated predictive display system is proposed whereby the operator can see a real-time model of the robot's environment and the delayed video picture on the monitor at the same time.
Fast algorithm of low power image reformation for OLED display
NASA Astrophysics Data System (ADS)
Lee, Myungwoo; Kim, Taewhan
2014-04-01
We propose a fast algorithm of low-power image reformation for organic light-emitting diode (OLED) display. The proposed algorithm scales the image histogram in a way to reduce power consumption in OLED display by remapping the gray levels of the pixels in the image based on the fast analysis of the histogram of the input image while maintaining contrast of the image. The key idea is that a large number of gray levels are never used in the images and these gray levels can be effectively exploited to reduce power consumption. On the other hand, to maintain the image contrast the gray level remapping is performed by taking into account the object size in the image to which each gray level is applied, that is, reforming little for the gray levels in the objects of large size. Through experiments with 24 Kodak images, it is shown that our proposed algorithm is able to reduce the power consumption by 10% even with 9% contrast enhancement. Our algorithm runs in a linear time so that it can be applied to moving pictures with high resolution.
Active-matrix OLED using 150°C a-Si TFT backplane built on flexible plastic substrate
NASA Astrophysics Data System (ADS)
Sarma, Kalluri R.; Chanley, Charles; Dodd, Sonia R.; Roush, Jared; Schmidt, John; Srdanov, Gordana; Stevenson, Matthew; Wessel, Ralf; Innocenzo, Jeffrey; Yu, Gang; O'Regan, Marie B.; MacDonald, W. A.; Eveson, R.; Long, Ke; Gleskova, Helena; Wagner, Sigurd; Sturm, James C.
2003-09-01
Flexible displays fabricated using plastic substrates have a potential for being very thin, light weight, highly rugged with greatly minimized propensity for breakage, roll-to-roll manufacturing and lower cost. The emerging OLED display media offers the advantage of being a solid state and rugged structure for flexible displays in addition to the many potential advantages of an AM OLED over the currently dominant AM LCD. The current high level of interest in flexible displays is facilitating the development of the required enabling technologies which include development of plastic substrates, low temperature active matrix device and backplane fabrication, and display packaging. In the following we will first discuss our development efforts in the PEN based plastic substrates, active matrix backplane technology, low temperature (150°C) a-Si TFT devices and an AM OLED test chip used for evaluating various candidate designs. We will then describe the design, fabrication and successful evaluation and demonstration of a 64x64 pixel AM OLED test display using a-Si TFT backplane fabricated at 150°C on the flexible plastic substrate.
ERIC Educational Resources Information Center
Reid, Caroline; Gill, Freya; Gore, Nick; Brady, Serena
2016-01-01
The current study presents findings from an acceptance and commitment therapy-based intervention for family carers of children who have an intellectual/developmental disability and display high levels of challenging behaviour. The parent well-being workshops consist of two workshops incorporating acceptance and mindfulness-based exercises and…
NASA Technical Reports Server (NTRS)
Kelly, J. R.
1983-01-01
A simulator investigation was conducted to determine the effect of the lead-aircraft ground-speed quantization level on self-spacing performance using a Cockpit Display of Traffic Information (CDTI). The study utilized a simulator employing cathode-ray tubes for the primary flight and navigation displays and highly augmented flight control modes. The pilot's task was to follow, and self-space on, a lead aircraft which was performing an idle-thrust profile descent to an instrument landing system (ILS) approach and landing. The spacing requirement was specified in terms of both a minimum distance and a time interval. The results indicate that the ground-speed quantization level, lead-aircraft scenario, and pilot technique had a significant effect on self-spacing performance. However, the ground-speed quantization level only had a significant effect on the performance when the lead aircraft flew a fast final approach.
Projection display industry market and technology trends
NASA Astrophysics Data System (ADS)
Castellano, Joseph A.; Mentley, David E.
1995-04-01
The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.
SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gauntt, D
2015-06-15
Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results ofmore » measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.« less
Leek, E Charles; d'Avossa, Giovanni; Tainturier, Marie-Josèphe; Roberts, Daniel J; Yuen, Sung Lai; Hu, Mo; Rafal, Robert
2012-01-01
This study examines how brain damage can affect the cognitive processes that support the integration of sensory input and prior knowledge during shape perception. It is based on the first detailed study of acquired ventral simultanagnosia, which was found in a patient (M.T.) with posterior occipitotemporal lesions encompassing V4 bilaterally. Despite showing normal object recognition for single items in both accuracy and response times (RTs), and intact low-level vision assessed across an extensive battery of tests, M.T. was impaired in object identification with overlapping figures displays. Task performance was modulated by familiarity: Unlike controls, M.T. was faster with overlapping displays of abstract shapes than with overlapping displays of common objects. His performance with overlapping common object displays was also influenced by both the semantic relatedness and visual similarity of the display items. These findings challenge claims that visual perception is driven solely by feedforward mechanisms and show how brain damage can selectively impair high-level perceptual processes supporting the integration of stored knowledge and visual sensory input.
Torpdahl, Mia; Lauderdale, Tsai-Ling; Liang, Shiu-Yun; Li, Ishien; Wei, Sung-Hsi; Chiou, Chien-Shun
2013-02-01
Salmonella enterica serovar Typhimurium is a major zoonotic pathogen with a high prevalence of antimicrobial resistance. This pathogen can disseminate across borders and spread far distances via the food trade and international travel. In this study, we compared the genotypes and antimicrobial resistance of 378 S. Typhimurium isolates collected in Taiwan and Denmark between 2009 and 2010. Genotyping revealed that many S. Typhimurium strains were concurrently circulating in Taiwan, Denmark and other countries in 2009 and 2010. When compared to the isolates collected from Denmark, the isolates from Taiwan displayed a significantly higher level of resistance to 11 of the 12 tested antimicrobials. Seven genetic clusters (A-G) were designated for the isolates. A high percentage of the isolates in genetic clusters C, F and G were multidrug-resistant. Of the isolates in cluster C, 79.2% were ASSuT-resistant, characterized by resistance to ampicillin, streptomycin, sulfamethoxazole, and tetracycline. In cluster F, 84.1% of the isolates were ACSSuT-resistant (resistant to ASSuT and chloramphenicol). Cluster G was unique to Taiwan and characterized in most isolates by the absence of three VNTRs (ST20, ST30 and STTR6) as well as a variety of multidrug resistance profiles. This cluster exhibited very high to extremely high levels of resistance to several first-line drugs, and among the seven clusters, it displayed the highest levels of resistance to cefotaxime and ceftazidime, ciprofloxacin and gentamicin. The high prevalence of antimicrobial resistance in S. Typhimurium from Taiwan highlights the necessity to strictly regulate the use of antimicrobials in the agriculture and human health care sectors. Copyright © 2012 Elsevier B.V. All rights reserved.
Proven high-performance display solution
NASA Astrophysics Data System (ADS)
Johnson, Rick J.; Shaw, James E.; Mosier, Don; Liss, Raymond L.; Prouty, Todd D.; Davis, Josh; Marzen, Vincent P.; Deloy, Christian T.
2002-08-01
Rockwell Collins serves both the military and the commercial segments by exploiting the common elements of these applications. Rockwell Collins has created a liquid crystal display family capable of 100:1 contrast ratio, 40:1 high ambient contrast, 0.25% specular reflectance, 0.1% diffuse reflectance, enhanced color stability over +/- 55H, 0-30V field of view, 300 fL with 10K:1 dimming range, color NVIS B compliance while exceeding environmental performance requirements though ruggedization. In order to meet the full range of display requirements at a system level, all the components must be understood and managed to meet the end solution of the final system. This paper details Rockwell Collins' optical performance using an avionics grade panel, third generation custom compensation, and solid state backlight.
Asha, G V; Raja Gopal Reddy, M; Mahesh, M; Vajreswari, A; Jeyakumar, S M
2016-01-01
Vitamin A and its metabolites are known to modulate adipose tissue development and its associated complications. Here, we assessed the vitamin A status and its metabolic pathway gene expression in relation to sexual dimorphism by employing 35 days old C57BL/6J male and female mice, which were fed either stock or high fat (HF) diet for 26 weeks. HF diet feeding increased body weight/weight gain and white adipose tissue (WAT) of visceral and subcutaneous regions, however, increase in vitamin A levels observed only in subcutaneous WAT. Further, the expression of most of the vitamin A metabolic pathway genes showed no sexual dimorphism. The observed HF diet-induced hyperglycaemia in male corroborates with increased retinol binding protein 4 (RBP4) levels in plasma and its expression in visceral adipose depots. In conclusion, the male mice are susceptible to high fat diet-induced hyperglycaemia and display higher plasma RBP4 levels, possibly due to its over-expression in visceral adipose depots.
Monitoring dynamic loads on wind tunnel force balances
NASA Technical Reports Server (NTRS)
Ferris, Alice T.; White, William C.
1989-01-01
Two devices have been developed at NASA Langley to monitor the dynamic loads incurred during wind-tunnel testing. The Balance Dynamic Display Unit (BDDU), displays and monitors the combined static and dynamic forces and moments in the orthogonal axes. The Balance Critical Point Analyzer scales and sums each normalized signal from the BDDU to obtain combined dynamic and static signals that represent the dynamic loads at predefined high-stress points. The display of each instrument is a multiplex of six analog signals in a way that each channel is displayed sequentially as one-sixth of the horizontal axis on a single oscilloscope trace. Thus this display format permits the operator to quickly and easily monitor the combined static and dynamic level of up to six channels at the same time.
The viewpoint-specific failure of modern 3D displays in laparoscopic surgery.
Sakata, Shinichiro; Grove, Philip M; Hill, Andrew; Watson, Marcus O; Stevenson, Andrew R L
2016-11-01
Surgeons conventionally assume the optimal viewing position during 3D laparoscopic surgery and may not be aware of the potential hazards to team members positioned across different suboptimal viewing positions. The first aim of this study was to map the viewing positions within a standard operating theatre where individuals may experience visual ghosting (i.e. double vision images) from crosstalk. The second aim was to characterize the standard viewing positions adopted by instrument nurses and surgical assistants during laparoscopic pelvic surgery and report the associated levels of visual ghosting and discomfort. In experiment 1, 15 participants viewed a laparoscopic 3D display from 176 different viewing positions around the screen. In experiment 2, 12 participants (randomly assigned to four clinically relevant viewing positions) viewed laparoscopic suturing in a simulation laboratory. In both experiments, we measured the intensity of visual ghosting. In experiment 2, participants also completed the Simulator Sickness Questionnaire. We mapped locations within the dimensions of a standard operating theatre at which visual ghosting may result during 3D laparoscopy. Head height relative to the bottom of the image and large horizontal eccentricities away from the surface normal were important contributors to high levels of visual ghosting. Conventional viewing positions adopted by instrument nurses yielded high levels of visual ghosting and severe discomfort. The conventional viewing positions adopted by surgical team members during laparoscopic pelvic operations are suboptimal for viewing 3D laparoscopic displays, and even short periods of viewing can yield high levels of discomfort.
Electronic data generation and display system
NASA Technical Reports Server (NTRS)
Wetekamm, Jules
1988-01-01
The Electronic Data Generation and Display System (EDGADS) is a field tested paperless technical manual system. The authoring provides subject matter experts the option of developing procedureware from digital or hardcopy inputs of technical information from text, graphics, pictures, and recorded media (video, audio, etc.). The display system provides multi-window presentations of graphics, pictures, animations, and action sequences with text and audio overlays on high resolution color CRT and monochrome portable displays. The database management system allows direct access via hierarchical menus, keyword name, ID number, voice command or touch of a screen pictoral of the item (ICON). It contains operations and maintenance technical information at three levels of intelligence for a total system.
Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C
2012-01-01
Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.
NASA Technical Reports Server (NTRS)
Rorie, Conrad; Fern, Lisa; Pack, Jessica; Shively, Jay; Draper, Mark H.
2015-01-01
The pilot-in-the-loop Detect-and-Avoid (DAA) task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays.
Held, Heike A; Sidhu, Sachdev S
2004-07-09
A peptide was fused to the C terminus of the M13 bacteriophage major coat protein (P8), and libraries of P8 mutants were screened to select for variants that displayed the peptide with high efficiency. Over 600 variants were sequenced to compile a comprehensive database of P8 sequence diversity compatible with assembly into the wild-type phage coat. The database reveals that, while the alpha-helical P8 molecule was highly tolerant to mutations, certain functional epitopes were required for efficient incorporation. Three hydrophobic epitopes were located approximately equidistantly along the length of the alpha-helix. In addition, a positively charged epitope was required directly opposite the most C-terminal hydrophobic epitope and on the same side as the other two epitopes. Both ends of the protein were highly tolerant to mutations, consistent with the use of P8 as a scaffold for both N and C-terminal phage display. Further rounds of selection were used to enrich for P8 variants that supported higher levels of C-terminal peptide display. The largest improvements in display resulted from mutations around the junction between P8 and the C-terminal linker, and additional mutations in the N-terminal region were selected for further improvements in display. The best P8 variants improved C-terminal display more than 100-fold relative to the wild-type, and these variants could support the simultaneous display of N and C-terminal fusions. These finding provide information on the requirements for filamentous phage coat assembly, and provide improved scaffolds for phage display technology. Copyright 2004 Elsevier Ltd.
High-efficiency white OLEDs based on small molecules
NASA Astrophysics Data System (ADS)
Hatwar, Tukaram K.; Spindler, Jeffrey P.; Ricks, M. L.; Young, Ralph H.; Hamada, Yuuhiko; Saito, N.; Mameno, Kazunobu; Nishikawa, Ryuji; Takahashi, Hisakazu; Rajeswaran, G.
2004-02-01
Eastman Kodak Company and SANYO Electric Co., Ltd. recently demonstrated a 15" full-color, organic light-emitting diode display (OLED) using a high-efficiency white emitter combined with a color-filter array. Although useful for display applications, white emission from organic structures is also under consideration for other applications, such as solid-state lighting, where high efficiency and good color rendition are important. By incorporating adjacent blue and orange emitting layers in a multi-layer structure, highly efficient, stable white emission has been attained. With suitable host and dopant combinations, a luminance yield of 20 cd/A and efficiency of 8 lm/W have been achieved at a drive voltage of less than 8 volts and luminance level of 1000 cd/m2. The estimated external efficiency of this device is 6.3% and a high level of operational stability is observed. To our knowledge, this is the highest performance reported so far for white organic electroluminescent devices. We will review white OLED technology and discuss the fabrication and operating characteristics of these devices.
High-resolution laser-projection display system using a grating electromechanical system (GEMS)
NASA Astrophysics Data System (ADS)
Brazas, John C.; Kowarz, Marek W.
2004-01-01
Eastman Kodak Company has developed a diffractive-MEMS spatial-light modulator for use in printing and display applications, the grating electromechanical system (GEMS). This modulator contains a linear array of pixels capable of high-speed digital operation, high optical contrast, and good efficiency. The device operation is based on deflection of electromechanical ribbons suspended above a silicon substrate by a series of intermediate supports. When electrostatically actuated, the ribbons conform to the supporting substructure to produce a surface-relief phase grating over a wide active region. The device is designed to be binary, switching between a reflective mirror state having suspended ribbons and a diffractive grating state having ribbons in contact with substrate features. Switching times of less than 50 nanoseconds with sub-nanosecond jitter are made possible by reliable contact-mode operation. The GEMS device can be used as a high-speed digital-optical modulator for a laser-projection display system by collecting the diffracted orders and taking advantage of the low jitter. A color channel is created using a linear array of individually addressable GEMS pixels. A two-dimensional image is produced by sweeping the line image of the array, created by the projection optics, across the display screen. Gray levels in the image are formed using pulse-width modulation (PWM). A high-resolution projection display was developed using three 1080-pixel devices illuminated by red, green, and blue laser-color primaries. The result is an HDTV-format display capable of producing stunning still and motion images with very wide color gamut.
Real-time synthetic vision cockpit display for general aviation
NASA Astrophysics Data System (ADS)
Hansen, Andrew J.; Smith, W. Garth; Rybacki, Richard M.
1999-07-01
Low cost, high performance graphics solutions based on PC hardware platforms are now capable of rendering synthetic vision of a pilot's out-the-window view during all phases of flight. When coupled to a GPS navigation payload the virtual image can be fully correlated to the physical world. In particular, differential GPS services such as the Wide Area Augmentation System WAAS will provide all aviation users with highly accurate 3D navigation. As well, short baseline GPS attitude systems are becoming a viable and inexpensive solution. A glass cockpit display rendering geographically specific imagery draped terrain in real-time can be coupled with high accuracy (7m 95% positioning, sub degree pointing), high integrity (99.99999% position error bound) differential GPS navigation/attitude solutions to provide both situational awareness and 3D guidance to (auto) pilots throughout en route, terminal area, and precision approach phases of flight. This paper describes the technical issues addressed when coupling GPS and glass cockpit displays including the navigation/display interface, real-time 60 Hz rendering of terrain with multiple levels of detail under demand paging, and construction of verified terrain databases draped with geographically specific satellite imagery. Further, on-board recordings of the navigation solution and the cockpit display provide a replay facility for post-flight simulation based on live landings as well as synchronized multiple display channels with different views from the same flight. PC-based solutions which integrate GPS navigation and attitude determination with 3D visualization provide the aviation community, and general aviation in particular, with low cost high performance guidance and situational awareness in all phases of flight.
The Sharjah Center for Astronomy and Space Sciences (SCASS 2015): Concept and Resources
NASA Astrophysics Data System (ADS)
Naimiy, Hamid M. K. Al
2015-08-01
The Sharjah Center for Astronomy and Space Sciences (SCASS) was launched this year 2015 at the University of Sharjah in the UAE. The center will serve to enrich research in the fields of astronomy and space sciences, promote these fields at all educational levels, and encourage community involvement in these sciences. SCASS consists of:The Planetarium: Contains a semi-circle display screen (18 meters in diameter) installed at an angle of 10° which displays high-definition images using an advanced digital display system consisting of seven (7) high-performance light-display channels. The Planetarium Theatre offers a 200-seat capacity with seats placed at highly calculated angles. The Planetarium also contains an enormous star display (Star Ball - 10 million stars) located in the heart of the celestial dome theatre.The Sharjah Astronomy Observatory: A small optical observatory consisting of a reflector telescope 45 centimeters in diameter to observe the galaxies, stars and planets. Connected to it is a refractor telescope of 20 centimeters in diameter to observe the sun and moon with highly developed astronomical devices, including a digital camera (CCD) and a high-resolution Echelle Spectrograph with auto-giving and remote calibration ports.Astronomy, space and physics educational displays for various age groups include:An advanced space display that allows for viewing the universe during four (4) different time periods as seen by:1) The naked eye; 2) Galileo; 3) Spectrographic technology; and 4) The space technology of today.A space technology display that includes space discoveries since the launching of the first satellite in 1940s until now.The Design Concept for the Center (450,000 sq. meters) was originated by HH Sheikh Sultan bin Mohammed Al Qasimi, Ruler of Sharjah, and depicts the dome as representing the sun in the middle of the center surrounded by planetary bodies in orbit to form the solar system as seen in the sky.
Raster graphics display library
NASA Technical Reports Server (NTRS)
Grimsrud, Anders; Stephenson, Michael B.
1987-01-01
The Raster Graphics Display Library (RGDL) is a high level subroutine package that give the advanced raster graphics display capabilities needed. The RGDL uses FORTRAN source code routines to build subroutines modular enough to use as stand-alone routines in a black box type of environment. Six examples are presented which will teach the use of RGDL in the fastest, most complete way possible. Routines within the display library that are used to produce raster graphics are presented in alphabetical order, each on a separate page. Each user-callable routine is described by function and calling parameters. All common blocks that are used in the display library are listed and the use of each variable within each common block is discussed. A reference on the include files that are necessary to compile the display library is contained. Each include file and its purpose are listed. The link map for MOVIE.BYU version 6, a general purpose computer graphics display system that uses RGDL software, is also contained.
Lateralisation of aggressive displays in a tephritid fly
NASA Astrophysics Data System (ADS)
Benelli, Giovanni; Donati, Elisa; Romano, Donato; Stefanini, Cesare; Messing, Russell H.; Canale, Angelo
2015-02-01
Lateralisation (i.e. different functional and/or structural specialisations of the left and right sides of the brain) of aggression has been examined in several vertebrate species, while evidence for invertebrates is scarce. In this study, we investigated lateralisation of aggressive displays (boxing with forelegs and wing strikes) in the Mediterranean fruit fly, Ceratitis capitata. We attempted to answer the following questions: (1) do medflies show lateralisation of aggressive displays at the population-level; (2) are there sex differences in lateralisation of aggressive displays; and (3) does lateralisation of aggression enhance fighting success? Results showed left-biased population-level lateralisation of aggressive displays, with no consistent differences among sexes. In both male-male and female-female conflicts, aggressive behaviours performed with left body parts led to greater fighting success than those performed with right body parts. As we found left-biased preferential use of body parts for both wing strikes and boxing, we predicted that the left foreleg/wing is quicker in exploring/striking than the right one. We characterised wing strike and boxing using high-speed videos, calculating mean velocity of aggressive displays. For both sexes, aggressive displays that led to success were faster than unsuccessful ones. However, left wing/legs were not faster than right ones while performing aggressive acts. Further research is needed on proximate causes allowing enhanced fighting success of lateralised aggressive behaviour. This is the first report supporting the adaptive role of lateralisation of aggressive displays in insects.
In sight, in mind: retailer compliance with legislation on limiting retail tobacco displays.
Quedley, Megan; Ng, Brendan; Sapre, Nikhil; Blakiston, Matthew; Crawford, Alexandra; Devadas, Rosanne; McLaren, Hamish; Anand, Shruti; Tipu, Mahu; Dayal, Viswas; Chandrasiri, Singithi; Thomson, George; Edwards, Richard
2008-08-01
We investigated retailer compliance with point-of-sale display legislation, using a New Zealand region as a case study. An observational survey was conducted of nonspecialist tobacco retailers in the lower North Island of New Zealand during 2006. Compliance was assessed in relation to store type (dairies, convenience stores, supermarkets, and service stations) and by characteristics of the population of the census area unit in which the store was situated. These characteristics include the level of socioeconomic deprivation and proportions of Maori (indigenous New Zealanders), Pacific Islanders, and children aged less than 19 years. Out of the 288 stores surveyed, 185 (64%) had at least one breach of the point-of-sale regulations. The most common breaches were a failure to display a "Smoking Kills" sign, visibility of tobacco from outside the premises, and displaying tobacco less than 1 m from children's products. Compliance was significantly worse in dairies (small local general stores) and convenience stores. Stores situated in areas in the top quartile for the proportion of children were much more likely to have high levels of noncompliance (> or =3 breaches) and to display tobacco products close to children's products. This study is one of very few to systematically investigate retailer compliance with point-of-sale display regulations for tobacco products. The results suggest that the implementation of legislation to partly limit retail displays of tobacco products can be difficult. A ban on retail displays of tobacco products is likely to be a more effective and enforceable policy.
Development and evaluation of a method of calibrating medical displays based on fixed adaptation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sund, Patrik, E-mail: patrik.sund@vgregion.se; Månsson, Lars Gunnar; Båth, Magnus
2015-04-15
Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrastmore » levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.« less
NASA Technical Reports Server (NTRS)
Rogers, William H.; Schutte, Paul C.
1993-01-01
Advanced fault management aiding concepts for commercial pilots are being developed in a research program at NASA Langley Research Center. One aim of this program is to re-evaluate current design principles for display of fault information to the flight crew: (1) from a cognitive engineering perspective and (2) in light of the availability of new types of information generated by advanced fault management aids. The study described in this paper specifically addresses principles for organizing fault information for display to pilots based on their mental models of fault management.
NASA Technical Reports Server (NTRS)
Bartolone, Anthony P.; Glabb, Louis J.; Hughes, Monica F.; Parrish, Russell V.
2005-01-01
Synthetic Vision Systems (SVS) displays provide pilots with a continuous view of terrain combined with integrated guidance symbology in an effort to increase situation awareness (SA) and decrease workload during operations in Instrument Meteorological Conditions (IMC). It is hypothesized that SVS displays can replicate the safety and operational flexibility of flight in Visual Meteorological Conditions (VMC), regardless of actual out-the-window (OTW) visibility or time of day. Significant progress has been made towards evolving SVS displays as well as demonstrating their ability to increase SA compared to conventional avionics in a variety of conditions. While a substantial amount of data has been accumulated demonstrating the capabilities of SVS displays, the ability of SVS to replicate the safety and operational flexibility of VMC flight performance in all visibility conditions is unknown to any specific degree. In order to more fully quantify the relationship of flight operations in IMC with SVS displays to conventional operations conducted in VMC, a fundamental comparison to current day general aviation (GA) flight instruments was warranted. Such a comparison could begin to establish the extent to which SVS display concepts are capable of maintaining an "equivalent level of safety" with the round dials they could one day replace, for both current and future operations. A combination of subjective and objective data measures were used to quantify the relationship between selected components of safety that are associated with flying an approach. Four information display methods ranging from a "round dials" baseline through a fully integrated SVS package that includes terrain, pathway based guidance, and a strategic navigation display, were investigated in this high fidelity simulation experiment. In addition, a broad spectrum of pilots, representative of the GA population, were employed for testing in an attempt to enable greater application of the results and determine if "equivalent levels of safety" are achievable through the incorporation of SVS technology regardless of a pilot's flight experience.
Li, Jinzhu; Ridgway, William; Fathman, C. Garrison; Tse, Harley Y.; Shaw, Michael K.
2008-01-01
Analysis of T regulatory cells (Treg) and T effector cells (Teff) in experimental autoimmune encephalomyelitis is complicated by the fact that both cell types express CD4 and CD25. We demonstrate that encephalitogenic T cells, following antigen recognition, up regulate cell surface expression of CD4. The CD4high sub-population contains all of the antigen response as shown by proliferation and cytokine secretion, and only these cells are capable of transferring EAE to naive animals. On the other hand, a FACS separable CD25+ sub-population of cells displayed consistent levels of CD4 prior to and after antigen stimulation. These cells displayed characteristics of Treg, such as expressing high levels of the Foxp3 gene and the ability to suppress mitogenic T cell responses. PMID:17920698
Methyl farnesoate levels in male spider crabs exhibiting active reproductive behavior.
Sagi, A; Ahl, J S; Danaee, H; Laufer, H
1994-09-01
The concentration of methyl farnesoate (MF) in the hemolymph and its synthesis by the mandibular organs (MOs) were investigated to determine whether this compound is related to the differences in the size of the reproductive system and the mating behavior among male morphotypes of the spider crab, Libinia emarginata. Large-claw abraded males displayed mating behavior under competitive conditions. They have the largest reproductive systems, their MOs synthesize large amounts of MF in vitro, and the concentration of MF in their hemolymph is high. Small-claw abraded males displayed mating behavior with receptive females only when isolated. These smaller crabs have intermediate-sized reproductive systems, their MOs synthesize the most MF, and they have the highest circulating level of MF relative to their body size. The unabraded males did not display mating behavior; their reproductive systems are smaller; their MO activity is low, as is their circulating level of MF. The strong relationship between MF levels and the intensity of reproductive behavior suggests that MF may be one of the driving forces behind mating behavior in Crustacea.
Coherence across consciousness levels: Symmetric visual displays spare working memory resources.
Dumitru, Magda L
2015-12-15
Two studies demonstrate that the need for coherence could nudge individuals to use structural similarities between binary visual displays and two concurrent cognitive tasks to unduly solve the latter in similar fashion. In an overt truth-judgement task, participants decided whether symmetric colourful displays matched conjunction or disjunction descriptions (e.g., "the black and/or the orange"). In the simultaneous covert categorisation task, they decided whether a colour name (e.g., "black") described a two-colour object or half of a single-colour object. Two response patterns emerged as follows. Participants either acknowledged or rejected matches between disjunction descriptions and two visual stimuli and, similarly, either acknowledged or rejected matches between single colour names and two-colour objects or between single colour names and half of single-colour objects. These findings confirm the coherence hypothesis, highlight the role of coherence in preserving working-memory resources, and demonstrate an interaction between high-level and low-level consciousness. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Doyon-Poulin, Philippe
Flight deck of 21st century commercial aircrafts does not look like the one the Wright brothers used for their first flight. The rapid growth of civilian aviation resulted in an increase in the number of flight deck instruments and of their complexity, in order to complete a safe and ontime flight. However, presenting an abundance of visual information using visually cluttered flight instruments might reduce the pilot's flight performance. Visual clutter has received an increased interest by the aerospace community to understand the effects of visual density and information overload on pilots' performance. Aerospace regulations demand to minimize visual clutter of flight deck displays. Past studies found a mixed effect of visual clutter of the primary flight display on pilots' technical flight performance. More research is needed to better understand this subject. In this thesis, we did an experimental study in a flight simulator to test the effects of visual clutter of the primary flight display on the pilot's technical flight performance, mental workload and gaze pattern. First, we identified a gap in existing definitions of visual clutter and we proposed a new definition relevant to the aerospace community that takes into account the context of use of the display. Then, we showed that past research on the effects of visual clutter of the primary flight display on pilots' performance did not manipulate the variable of visual clutter in a similar manner. Past research changed visual clutter at the same time than the flight guidance function. Using a different flight guidance function between displays might have masked the effect of visual clutter on pilots' performance. To solve this issue, we proposed three requirements that all tested displays must satisfy to assure that only the variable of visual clutter is changed during study while leaving other variables unaffected. Then, we designed three primary flight displays with a different visual clutter level (low, medium, high) but with the same flight guidance function, by respecting the previous requirements. Twelve pilots, with a mean experience of over 4000 total flight hours, completed an instrument landing in a flight simulator using all three displays for a total of nine repetitions. Our results showed that pilots reported lower workload level and had better lateral precision during the approach using the medium-clutter display compared to the low- and high-clutter displays. Also, pilots reported that the medium-clutter display was the most useful for the flight task compared to the two other displays. Eye tracker results showed that pilots' gaze pattern was less efficient for the high-clutter display compared to the low- and medium-clutter displays. Overall, these new experimental results emphasize the importance of optimizing visual clutter of flight displays as it affects both objective and subjective performance of experienced pilots in their flying task. This thesis ends with practical recommendations to help designers optimize visual clutter of displays used for man-machine interface.
Droulers, Olivier; Lacoste-Badie, Sophie; Lajante, Mathieu
2017-01-01
The first aim of this research was to assess the effectiveness, in terms of emotional and behavioral reactions, of moderately vs. highly TVWs (Threatening Visual Warnings) displayed on tobacco packs. Given the key role that emotional reactions play in explaining the effect of TVWs on behaviors, psychophysiological and self-report methods were used–for the first time in this context–to measure the emotions provoked by TVWs. The second aim of this research was to determine whether increasing the size of warnings, and their display on plain packaging (compared with branded packaging) would improve their effectiveness. A within-subjects experiment was conducted. Three variables were manipulated: health warning threat level (high vs. moderate), image size (40% vs. 75%) and pack type (plain vs. branded). A convenience sample of 48 French daily smokers participated. They were exposed to eight different packs of cigarettes in a research lab at the University of Rennes. Smokers’ emotions and behavioral intentions were recorded through self-reports. Emotions were also evaluated using psychophysiological measurements: electrodermal activity and facial electromyography. The results revealed that TVWs with a high threat level are the most effective in increasing negative emotions (fear, disgust, valence, arousal) and behavioral intentions conducive to public health (desire to quit, etc.). They also highlight the appeal of increasing the size of the warnings and displaying them on plain packs, because this influences emotions, which is the first step toward behavioral change. Increasing the threat level of TVWs from moderate to high seems beneficial for public health. Our results also confirm the relevance of recent governmental decisions to adopt plain packaging and larger TVWs (in the UK, France, Ireland, Canada, New Zealand, Hungary, etc.). PMID:28910317
Droulers, Olivier; Gallopel-Morvan, Karine; Lacoste-Badie, Sophie; Lajante, Mathieu
2017-01-01
The first aim of this research was to assess the effectiveness, in terms of emotional and behavioral reactions, of moderately vs. highly TVWs (Threatening Visual Warnings) displayed on tobacco packs. Given the key role that emotional reactions play in explaining the effect of TVWs on behaviors, psychophysiological and self-report methods were used-for the first time in this context-to measure the emotions provoked by TVWs. The second aim of this research was to determine whether increasing the size of warnings, and their display on plain packaging (compared with branded packaging) would improve their effectiveness. A within-subjects experiment was conducted. Three variables were manipulated: health warning threat level (high vs. moderate), image size (40% vs. 75%) and pack type (plain vs. branded). A convenience sample of 48 French daily smokers participated. They were exposed to eight different packs of cigarettes in a research lab at the University of Rennes. Smokers' emotions and behavioral intentions were recorded through self-reports. Emotions were also evaluated using psychophysiological measurements: electrodermal activity and facial electromyography. The results revealed that TVWs with a high threat level are the most effective in increasing negative emotions (fear, disgust, valence, arousal) and behavioral intentions conducive to public health (desire to quit, etc.). They also highlight the appeal of increasing the size of the warnings and displaying them on plain packs, because this influences emotions, which is the first step toward behavioral change. Increasing the threat level of TVWs from moderate to high seems beneficial for public health. Our results also confirm the relevance of recent governmental decisions to adopt plain packaging and larger TVWs (in the UK, France, Ireland, Canada, New Zealand, Hungary, etc.).
High performance visual display for HENP detectors
NASA Astrophysics Data System (ADS)
McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel
2001-08-01
A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations.
Fassino, Secondo; Amianto, Federico; Gastaldi, Filippo; Abbate-Daga, Giovanni; Brambilla, Francesca; Leombruni, Paolo
2009-01-30
Family environment is a pathogenic factor of borderline personality disorder (BPD). However, the personality traits of patients with BPD and their parents have never been assessed using the same instrument and then examined for relationships. In the present study, we explored the temperament and character traits of BPD patients and their parents to investigate possible interactions. In total, 56 patients with BPD and their parents were evaluated with the Temperament and Character Inventory (TCI) and compared with 53 control families. Discriminant and correlation analyses indicated that subjects with BPD displayed higher levels of novelty seeking, harm avoidance, and self-transcendence and lower levels of self-directedness than control subjects. Their fathers displayed higher levels of novelty seeking and lower levels of persistence and self-directedness, and their mothers displayed lower levels of self-directedness compared with levels in control parents. In BPD families, temperament and character traits displayed high levels of discriminatory power. Novelty seeking in offspring with borderline personality disorder was significantly correlated with their mothers' novelty seeking and their fathers' self-transcendence. Self-directedness in borderline offspring was significantly correlated with both their mothers' and fathers' novelty seeking, and their self-transcendence was significantly correlated with their mothers' novelty seeking and harm avoidance. The different correlational pattern for borderline and control families is discussed. Characteristic personality patterns were found in BPD offspring and in both parents. The relationship between personality traits of borderline offspring and those of their parents may be related to both genetic transmission and family dynamics. Ramifications for treatment are discussed.
Yagil, Dana; Shnapper-Cohen, Moran
2016-10-01
The emotions expressed by physicians in medical encounters have significant impact on health outcomes and patient satisfaction. This study explored how physicians' regulation of displayed emotions affects patients' satisfaction, under low and high levels of patient distress and length of physician-patient acquaintance. Questionnaires were administered to 46 physicians and 230 of their patients (before and after the medical encounter) in outpatient clinics of two hospitals. Data were analyzed with hierarchical linear modeling which takes the nested data structure into account. We found a significant interaction effect of physician regulation of displayed emotions and patient distress on satisfaction: When distress was high, physician regulation of emotions was negatively related to patient satisfaction. The results also show a significant interaction effect of physician regulation of displayed emotions and length of physician-patient acquaintance: With a longer acquaintance, physician regulation of emotions was negatively related to patient satisfaction. The effect of the physicians' emotional display on patient satisfaction depends on contextual factors, such as patient distress and length of physician-patient acquaintance, which affect patients' emotional needs and expectations. When patients have high emotional involvement in the encounter it is suggested that physicians consider presenting genuine emotions to patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Average power scaling of UV excimer lasers drives flat panel display and lidar applications
NASA Astrophysics Data System (ADS)
Herbst, Ludolf; Delmdahl, Ralph F.; Paetzel, Rainer
2012-03-01
Average power scaling of 308nm excimer lasers has followed an evolutionary path over the last two decades driven by diverse industrial UV laser microprocessing markets. Recently, a new dual-oscillator and beam management concept for high-average power upscaling of excimer lasers has been realized, for the first time enabling as much as 1.2kW of stabilized UV-laser average output power at a UV wavelength of 308nm. The new dual-oscillator concept enables low temperature polysilicon (LTPS) fabrication to be extended to generation six glass substrates. This is essential in terms of a more economic high-volume manufacturing of flat panel displays for the soaring smartphone and tablet PC markets. Similarly, the cost-effective production of flexible displays is driven by 308nm excimer laser power scaling. Flexible displays have enormous commercial potential and can largely use the same production equipment as is used for rigid display manufacturing. Moreover, higher average output power of 308nm excimer lasers aids reducing measurement time and improving the signal-to-noise ratio in the worldwide network of high altitude Raman lidar stations. The availability of kW-class 308nm excimer lasers has the potential to take LIDAR backscattering signal strength and achievable altitude to new levels.
NASA Astrophysics Data System (ADS)
Ismail, R.; Perwitasari, D. A.; Supadmi, W.; Risdiana, I.
2017-11-01
Prescription screening includes administrative and clinical precision of the drug, dosage, frequency and route of administration, therapeutic duplication, allergic or sensitive reactions, and actual or potential interactions. The study was aimed to identify the obstacles and compliance level of users, as well as the design of a prescription screening information system and its users’ perceptions. This study used qualitative and quantitative research design with action research studies involving pharmacists, pharmacy technicians, a programmer and clinical practice student pharmacists. The obstacle of pharmacists in doing prescription screening was the long duration in the process of manual prescription review. The compliance of pharmacists in manual prescription review was under 50%. The prescription information system was created by the programmer on the proposal of pharmacists in the form of front view, pharmacy display, sales display, prescription display, prescription display per period and display of recapped prescriptions. Perception of the usefulness was very high with a value of 4.5±0.577 and perception of ease of use was very high with a value of 4.214±0.534 from 28 respondents. The prescription information system was created by a programmer upon the recommendations of pharmacists. Perception of the usefulness and ease of use was very high.
Spatial displays as a means to increase pilot situational awareness
NASA Technical Reports Server (NTRS)
Fadden, Delmar M.; Braune, Rolf; Wiedemann, John
1989-01-01
Experiences raise a number of concerns for future spatial-display developers. While the promise of spatial displays is great, the cost of their development will be correspondingly large. The knowledge and skills which must be coordinated to ensure successful results is unprecedent. From the viewpoint of the designer, basic knowledge of how human beings perceive and process complex displays appears fragmented and largely unquantified. Methodologies for display development require prototyping and testing with subject pilots for even small changes. Useful characterizations of the range of differences between individual users is nonexistent or at best poorly understood. The nature, significance, and frequency of interpretation errors associated with complex integrated displays is unexplored and undocumented territory. Graphic displays have intuitive appeal and can achieve face validity much more readily than earlier symbolic displays. The risk of misleading the pilot is correspondingly greater. Thus while some in the research community are developing the tools and techniques necessary for effective spatial-display development, potential users must be educated about the issues so that informed choices can be made. The scope of the task facing all is great. The task is challenging and the potential for meaningful contributions at all levels is high indeed.
Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence
NASA Astrophysics Data System (ADS)
Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas
2007-02-01
Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.
NASA Astrophysics Data System (ADS)
Schiefele, Jens; Bader, Joachim; Kastner, S.; Wiesemann, Thorsten; von Viebahn, Harro
2002-07-01
Next generation of cockpit display systems will display mass data. Mass data includes terrain, obstacle, and airport databases. Display formats will be two and eventually 3D. A prerequisite for the introduction of these new functions is the availability of certified graphics hardware. The paper describes functionality and required features of an aviation certified 2D/3D graphics board. This graphics board should be based on low-level and hi-level API calls. These graphic calls should be very similar to OpenGL. All software and the API must be aviation certified. As an example application, a 2D airport navigation function and a 3D terrain visualization is presented. The airport navigation format is based on highly precise airport database following EUROCAE ED-99/RTCA DO-272 specifications. Terrain resolution is based on EUROCAE ED-98/RTCA DO-276 requirements.
NASA Astrophysics Data System (ADS)
Sarma, Kalluri
2015-05-01
Organic light emitting diode (OLED) display technology has advanced significantly in recent years and it is increasingly being adapted in consumer electronics products with premium performance, such as high resolution smart phones, Tablet PCs and TVs. Even flexible OLED displays are beginning to be commercialized in consumer electronic devices such as smart phones and smart watches. In addition to the advances in OLED emitters, successful development and adoption of OLED displays for premium performance applications relies on the advances in several enabling technologies including TFT backplanes, pixel drive electronics, pixel patterning technologies, encapsulation technologies and system level engineering. In this paper we will discuss the impact of the recent advances in LTPS and AOS TFTs, R, G, B and White OLED with color filter pixel architectures, and encapsulation, on the success of the OLEDs in consumer electronic devices. We will then discuss potential of these advances in addressing the requirements of OLED and flexible displays for the military and avionics applications.
Use of sonification in the detection of anomalous events
NASA Astrophysics Data System (ADS)
Ballora, Mark; Cole, Robert J.; Kruesi, Heidi; Greene, Herbert; Monahan, Ganesh; Hall, David L.
2012-06-01
In this paper, we describe the construction of a soundtrack that fuses stock market data with information taken from tweets. This soundtrack, or auditory display, presents the numerical and text data in such a way that anomalous events may be readily detected, even by untrained listeners. The soundtrack generation is flexible, allowing an individual listener to create a unique audio mix from the available information sources. Properly constructed, the display exploits the auditory system's sensitivities to periodicities, to dynamic changes, and to patterns. This type of display could be valuable in environments that demand high levels of situational awareness based on multiple sources of incoming information.
The Fundamentals of Using the Digital Micromirror Device (DMD(TM)) for Projection Display
NASA Technical Reports Server (NTRS)
Yoder, Lars A.
1995-01-01
Developed by Texas Instruments (TI) the digital micromirror device (DMD(tm)) is a quickly emerging and highly useful micro-electro-mechanical structures (MEMS) device. Using standard semiconductor fabrication technology, the DMD's simplicity in concept and design will provide advantageous solutions for many different applications. At the rudimentary level, the DMD is a precision, semiconductor light switch. In the initial commercial development of DMD technology, TI has concentrated on projection display and hardcopy. This paper will focus on how the DMD is used for projection display. Other application areas are being explored and evaluated to find appropriate and beneficial uses for the DMD.
Rangiani, Afsaneh; Cao, Zheng-Guo; Liu, Ying; Voisey Rodgers, Anika; Jiang, Yong; Qin, Chun-Lin; Feng, Jian-Quan
2012-01-01
Deletion or mutation of dentin matrix protein 1 (DMP1) leads to hypophosphatemic rickets and defects within the dentin. However, it is largely unknown if this pathological change is a direct role of DMP1 or an indirect role of phosphate (Pi) or both. It has also been previously shown that Klotho-deficient mice, which displayed a high Pi level due to a failure of Pi excretion, causes mild defects in the dentinal structure. This study was to address the distinct roles of DMP1 and Pi homeostasis in cell differentiation, apoptosis and mineralization of dentin and enamel. Our working hypothesis was that a stable Pi homeostasis is critical for postnatal tooth formation, and that DMP1 has an antiapoptotic role in both amelogenesis and dentinogenesis. To test this hypothesis, Dmp1-null (Dmp1−/−), Klotho-deficient (kl/kl), Dmp1/Klotho-double-deficient (Dmp1−/−/kl/kl) and wild-type (WT) mice were killed at the age of 6 weeks. Combinations of X-ray, microcomputed tomography (μCT), scanning electron microscopy (SEM), histology, apoptosis and immunohistochemical methods were used for characterization of dentin, enamel and pulp structures in these mutant mice. Our results showed that Dmp1−/− (a low Pi level) or kl/kl (a high Pi level) mice displayed mild dentin defects such as thin dentin and a reduction of dentin tubules. Neither deficient mouse line exhibited any apparent changes in enamel or pulp structure. However, the double-deficient mice (a high Pi level) displayed severe defects in dentin and enamel structures, including loss of dentinal tubules and enamel prisms, as well as unexpected ectopic ossification within the pulp root canal. TUNEL assay showed a sharp increase in apoptotic cells in ameloblasts and odontoblasts. Based on the above findings, we conclude that DMP1 has a protective role for odontoblasts and ameloblasts in a pro-apoptotic environment (a high Pi level). PMID:23258378
Solid-state turn coordinator display
NASA Technical Reports Server (NTRS)
Meredith, B. D.; Crouch, R. K.; Kelly, W. L., IV
1975-01-01
A solid state turn coordinator display which employs light emitting diodes (LED's) as the display medium was developed to demonstrate the feasibility of such displays for aircraft applications. The input to the display is supplied by a fluidic inertial rate sensor used in an aircraft wing leveler system. The display is composed of the LED radial display face and the electronics necessary to address and drive the individual lines of LED's. Three levels of brightness are provided to compensate for the different amounts of ambient light present in the cockpit.
NASA Astrophysics Data System (ADS)
Schuck, Miller Harry
Automotive head-up displays require compact, bright, and inexpensive imaging systems. In this thesis, a compact head-up display (HUD) utilizing liquid-crystal-on-silicon microdisplay technology is presented from concept to implementation. The thesis comprises three primary areas of HUD research: the specification, design and implementation of a compact HUD optical system, the development of a wafer planarization process to enhance reflective device brightness and light immunity and the design, fabrication and testing of an inexpensive 640 x 512 pixel active matrix backplane intended to meet the HUD requirements. The thesis addresses the HUD problem at three levels, the systems level, the device level, and the materials level. At the systems level, the optical design of an automotive HUD must meet several competing requirements, including high image brightness, compact packaging, video-rate performance, and low cost. An optical system design which meets the competing requirements has been developed utilizing a fully-reconfigurable reflective microdisplay. The design consists of two optical stages, the first a projector stage which magnifies the display, and a second stage which forms the virtual image eventually seen by the driver. A key component of the optical system is a diffraction grating/field lens which forms a large viewing eyebox while reducing the optical system complexity. Image quality biocular disparity and luminous efficacy were analyzed and results of the optical implementation are presented. At the device level, the automotive HUD requires a reconfigurable, video-rate, high resolution image source for applications such as navigation and night vision. The design of a 640 x 512 pixel active matrix backplane which meets the requirements of the HUD is described. The backplane was designed to produce digital field sequential color images at video rates utilizing fast switching liquid crystal as the modulation layer. The design methodology is discussed, and the example of a clock generator is described from design to implementation. Electrical and optical test results of the fabricated backplane are presented. At the materials level, a planarization method was developed to meet the stringent brightness requirements of automotive HUD's. The research efforts described here have resulted in a simple, low cost post-processing method for planarizing microdisplay substrates based on a spin-cast polymeric resin, benzocyclobutene (BCB). Six- fold reductions in substrate step height were accomplished with a single coating. Via masking and dry etching methods were developed. High reflectivity metal was deposited and patterned over the planarized substrate to produce high aperture pixel mirrors. The process is simple, rapid, and results in microdisplays better able to meet the stringent requirements of high brightness display systems. Methods and results of the post- processing are described.
Guillaud-Bataille, M; Brison, O; Danglot, G; Lavialle, C; Raynal, B; Lazar, V; Dessen, P; Bernheim, A
2009-01-01
High-level amplifications observed in tumor cells are usually indicative of genes involved in oncogenesis. We report here a high resolution characterization of a new amplified region in the SW613-S carcinoma cell line. This cell line contains tumorigenic cells displaying high-level MYC amplification in the form of double minutes (DM(+) cells) and non tumorigenic cells exhibiting low-level MYC amplification in the form of homogeneously staining regions (DM(-) cells). Both cell types were studied at genomic and functional levels. The DM(+) cells display a second amplification, corresponding to the 14q24.1 region, in a distinct population of DMs. The 0.43-Mb amplified and overexpressed region contains the PLEK2, PIGH, ARG2, VTI1B, RDH11, and ZFYVE26 genes. Both amplicons were stably maintained upon in vitro and in vivo propagation. However, the 14q24.1 amplicon was not found in cells with high-level MYC amplification in the form of HSRs, either obtained after spontaneous integration of endogenous DM MYC copies or after transfection of DM(-) cells with a MYC gene expression vector. These HSR-bearing cells are highly tumorigenic. The 14q24.1 amplification may not play a role in malignancy per se but might contribute to maintaining the amplification in the form of DMs. Copyright 2009 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.; Bech, Søren; Andersen, Jakob Dahl; Forchhammer, Søren
2015-01-01
This paper focuses on the influence of ambient light on the perceived quality of videos displayed on Liquid Crystal Display (LCD) with local backlight dimming. A subjective test assessing the quality of videos with two backlight dimming methods and three lighting conditions, i.e. no light, low light level (5 lux) and higher light level (60 lux) was organized to collect subjective data. Results show that participants prefer the method exploiting local dimming possibilities to the conventional full backlight but that this preference varies depending on the ambient light level. The clear preference for one method at the low light conditions decreases at the high ambient light, confirming that the ambient light significantly attenuates the perception of the leakage defect (light leaking through dark pixels). Results are also highly dependent on the content of the sequence, which can modulate the effect of the ambient light from having an important influence on the quality grades to no influence at all.
Li, Tian-Tian; Lu, Yong
2014-11-07
This study on the subliminal affective priming effects of faces displaying various levels of arousal employed event-related potentials (ERPs). The participants were asked to rate the arousal of ambiguous medium-arousing faces that were preceded by high- or low-arousing priming faces presented subliminally. The results revealed that the participants exhibited arousal-consistent variation in their arousal level ratings of the probe faces exclusively in the negative prime condition. Compared with high-arousing faces, the low-arousing faces tended to elicit greater late positive component (LPC, 450-660ms) and greater N400 (330-450ms) potentials. These findings support the following conclusions: (1) the effect of subliminal affective priming of faces can be detected in the affective arousal dimension; (2) valence may influence the subliminal affective priming effect of the arousal dimension of emotional stimuli; and (3) the subliminal affective priming effect of face arousal occurs when the prime stimulus affects late-stage processing of the probe. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Highly Reflective Multi-stable Electrofluidic Display Pixels
NASA Astrophysics Data System (ADS)
Yang, Shu
Electronic papers (E-papers) refer to the displays that mimic the appearance of printed papers, but still owning the features of conventional electronic displays, such as the abilities of browsing websites and playing videos. The motivation of creating paper-like displays is inspired by the truths that reading on a paper caused least eye fatigue due to the paper's reflective and light diffusive nature, and, unlike the existing commercial displays, there is no cost of any form of energy for sustaining the displayed image. To achieve the equivalent visual effect of a paper print, an ideal E-paper has to be a highly reflective with good contrast ratio and full-color capability. To sustain the image with zero power consumption, the display pixels need to be bistable, which means the "on" and "off" states are both lowest energy states. Pixel can change its state only when sufficient external energy is given. There are many emerging technologies competing to demonstrate the first ideal E-paper device. However, none is able to achieve satisfactory visual effect, bistability and video speed at the same time. Challenges come from either the inherent physical/chemical properties or the fabrication process. Electrofluidic display is one of the most promising E-paper technologies. It has successfully demonstrated high reflectivity, brilliant color and video speed operation by moving colored pigment dispersion between visible and invisible places with electrowetting force. However, the pixel design did not allow the image bistability. Presented in this dissertation are the multi-stable electrofluidic display pixels that are able to sustain grayscale levels without any power consumption, while keeping the favorable features of the previous generation electrofluidic display. The pixel design, fabrication method using multiple layer dry film photoresist lamination, and physical/optical characterizations are discussed in details. Based on the pixel structure, the preliminary results of a simplified design and fabrication method are demonstrated. As advanced research topics regarding the device optical performance, firstly an optical model for evaluating reflective displays' light out-coupling efficiency is established to guide the pixel design; Furthermore, Aluminum surface diffusers are analytically modeled and then fabricated onto multi-stable electrofluidic display pixels to demonstrate truly "white" multi-stable electrofluidic display modules. The achieved results successfully promoted multi-stable electrofluidic display as excellent candidate for the ultimate E-paper device especially for larger scale signage applications.
Adiposity signals predict vocal effort in Alston's singing mice.
Burkhard, Tracy T; Westwick, Rebecca R; Phelps, Steven M
2018-04-25
Advertisement displays often seem extravagant and expensive, and are thought to depend on the body condition of a signaller. Nevertheless, we know little about how signallers adjust effort based on condition, and few studies find a strong relationship between natural variation in condition and display. To examine the relationship between body condition and signal elaboration more fully, we characterized physiological condition and acoustic displays in a wild rodent with elaborate vocalizations, Alston's singing mouse, Scotinomys teguina We found two major axes of variation in condition-one defined by short-term fluctuations in caloric nutrients, and a second by longer-term variation in adiposity. Among acoustic parameters, song effort was characterized by high rates of display and longer songs. Song effort was highly correlated with measures of adiposity. We found that leptin was a particularly strong predictor of display effort. Leptin is known to influence investment in other costly traits, such as immune function and reproduction. Plasma hormone levels convey somatic state to a variety of tissues, and may govern trait investment across vertebrates. Such measures offer new insights into how animals translate body condition into behavioural and life-history decisions. © 2018 The Author(s).
Responding to a Challenging Perceptual-Motor Task as a Function of Level of Experiential Avoidance
ERIC Educational Resources Information Center
Zettle, Robert D.; Petersen, Connie L.; Hocker, Tanya R.; Provines, Jessica L.
2007-01-01
Participants displaying high versus low levels of experiential avoidance as assessed by the Acceptance and Action Questionnaire (Hayes, Strosahl, et al., 2004) were compared in their reactions to and performance on a challenging perceptual-motor task. Participants were offered incentives for sorting colored straws into different colored containers…
High-quality remote interactive imaging in the operating theatre
NASA Astrophysics Data System (ADS)
Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan
2009-02-01
We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.
M13 bacteriophage coat proteins engineered for improved phage display.
Sidhu, Sachdev S; Feld, Birte K; Weiss, Gregory A
2007-01-01
This chapter describes a method for increasing levels of protein fusions displayed on the surfaces of M13 bacteriophage particles. By introducing mutations into the anchoring M13 coat protein, protein display levels can be increased by up to two orders of magnitude. Experimental methods are presented for the design, construction, and screening of phage-displayed libraries for improved protein display.
Webb, L E; van Reenen, C G; Engel, B; Berends, H; Gerrits, W J J; Bokkers, E A M
2017-06-01
Stereotypies are used as indicators of poor animal welfare and it is, therefore, important to understand underlying factors mediating their development. In calves, two oral stereotypies, that is, tongue playing and object manipulation, result mostly from insufficient structure in the diet. Three hypotheses were studied: (1) oral stereotypies in calves are one of two alternative strategies, the alternative being hypo-activity; (2) stereotyping and non-stereotyping calves differ in terms of cortisol secretion; (3) oral stereotypy development in calves rests on a gene by environment interaction. Eight-week-old bull calves (n=48) were assigned to one of four solid feed allowances (0, 9, 18 or 27 g dry matter/kg metabolic weight per day) with the following composition: 50% concentrate, 25% maize silage and 25% straw on dry matter basis. The calves received milk replacer in buckets, the provision of which was adjusted to achieve equal growth rates. At 14 to 18 weeks of age, calves were exposed to a challenge, that is, tethering inside cages. Oral stereotypies and inactivity were recorded in the home pens in the 4 weeks before the challenge using instantaneous scan sampling. Salivary cortisol levels were measured at -120, +40, +80, +120 min and +48 h relative to the challenge. Individual differences in behaviour were recorded in the first 30 min after challenge implementation using focal animal sampling and continuous recording, and these elements were entered into a principal component (PC) analysis to extract PCs. Regression analyses were performed to find relationships between stereotypies and inactivity, stereotypies and cortisol, and stereotypies and PCs (individual differences, genes) and solid feed (environment). Relationships between PCs and cortisol were also investigated to help with the interpretation of PCs. Hypotheses 1 and 2 were rejected. Hypothesis 3, however, was supported: calves with a zero solid feed allowance, that is, in the most barren environment, showed links between stereotypies and two of the PCs. Calves that displayed high levels of idle and rapid locomotion and low levels of oral contact with the cage during the challenge also displayed high levels of object manipulation in the home pens. Calves that displayed low levels of stepping and turning attempts during the challenge also displayed high levels of tongue playing in the home pens. This study corroborates the gene by environment interaction on the development of oral stereotypies in calves.
Gaze-contingent displays: a review.
Duchowski, Andrew T; Cournia, Nathan; Murphy, Hunter
2004-12-01
Gaze-contingent displays (GCDs) attempt to balance the amount of information displayed against the visual information processing capacity of the observer through real-time eye movement sensing. Based on the assumed knowledge of the instantaneous location of the observer's focus of attention, GCD content can be "tuned" through several display processing means. Screen-based displays alter pixel level information generally matching the resolvability of the human retina in an effort to maximize bandwidth. Model-based displays alter geometric-level primitives along similar goals. Attentive user interfaces (AUIs) manage object- level entities (e.g., windows, applications) depending on the assumed attentive state of the observer. Such real-time display manipulation is generally achieved through non-contact, unobtrusive tracking of the observer's eye movements. This paper briefly reviews past and present display techniques as well as emerging graphics and eye tracking technology for GCD development.
Deep Space Network Antenna Logic Controller
NASA Technical Reports Server (NTRS)
Ahlstrom, Harlow; Morgan, Scott; Hames, Peter; Strain, Martha; Owen, Christopher; Shimizu, Kenneth; Wilson, Karen; Shaller, David; Doktomomtaz, Said; Leung, Patrick
2007-01-01
The Antenna Logic Controller (ALC) software controls and monitors the motion control equipment of the 4,000-metric-ton structure of the Deep Space Network 70-meter antenna. This program coordinates the control of 42 hydraulic pumps, while monitoring several interlocks for personnel and equipment safety. Remote operation of the ALC runs via the Antenna Monitor & Control (AMC) computer, which orchestrates the tracking functions of the entire antenna. This software provides a graphical user interface for local control, monitoring, and identification of faults as well as, at a high level, providing for the digital control of the axis brakes so that the servo of the AMC may control the motion of the antenna. Specific functions of the ALC also include routines for startup in cold weather, controlled shutdown for both normal and fault situations, and pump switching on failure. The increased monitoring, the ability to trend key performance characteristics, the improved fault detection and recovery, the centralization of all control at a single panel, and the simplification of the user interface have all reduced the required workforce to run 70-meter antennas. The ALC also increases the antenna availability by reducing the time required to start up the antenna, to diagnose faults, and by providing additional insight into the performance of key parameters that aid in preventive maintenance to avoid key element failure. The ALC User Display (AUD) is a graphical user interface with hierarchical display structure, which provides high-level status information to the operation of the ALC, as well as detailed information for virtually all aspects of the ALC via drill-down displays. The operational status of an item, be it a function or assembly, is shown in the higher-level display. By pressing the item on the display screen, a new screen opens to show more detail of the function/assembly. Navigation tools and the map button allow immediate access to all screens.
NASA Technical Reports Server (NTRS)
Batson, Vernon M.; Robertson, James B.; Parrish, Russell V.
1990-01-01
The aircraft cockpit ambient lighting simulation system (ACALSS) has been developed to study display readability and associated pilot/vehicle performance effects in a part-task simulator cockpit. In the study reported here, the ACALSS was used to determine the illumination levels at which subjects lose the ability to maintain aircraft states when using three display technologies as display media for primary flight displays: a standard monochrome EL (electroluminescent) flat-panel, a laboratory-class monochrome CRT, and an enhanced-brightness EL flat-panel. The multivariate statistical technique of modified profile analysis was used to test for performance differences between display devices as functions of illumination levels. The standard monochrome EL flat-panel display began to washout after the 2500 foot-candle level of illumination. The monochrome CRT began to washout after the 5500 foot-candle level of illumination. No performance decrements by increased illumination up to the 12,000 foot-candle level were found for the enhanced-brightness EL flat-panel display. What was not anticipated was that half the subjects would subjectively prefer the CRT over the enhanced-brightness EL, even though their performance errors would have indicated the opposite.
Smith, M A; Bush, R D; van de Ven, R J; Hall, E J S; Greenwood, P L; Hopkins, D L
2017-01-01
Meat quality parameters for 50 huacaya alpacas, representing three age groups (18, 24 and 36months) and two genders (females and castrated males) were studied. Prior to chilling, samples of m. longissimus thoracis et lumborum (LL) were taken to determine isocitrate dehydrogenase activity and glycogen concentration, and further meat quality samples were taken after 24h. Alpaca meat has low levels (<1%) of intramuscular fat in the LL, m. semimembranosus and m. biceps femoris, but the level in the LL increases with animal age, with levels of desirable polyunsaturated fatty acids (PUFA) ranging from 96.3 to 136.4mg/100g. Lipid oxidisation post retail display ranged from 1.27 to 1.96MDA/kg meat. Colour stability testing indicated alpaca meat was relatively stable during retail display with day of display having no significant effect on lightness (L*), or the 630nm/580nm ratio. These results may relate to the high proportion (76%) of glycolytic and type IIX muscle fibres in LL. Copyright © 2016 Elsevier Ltd. All rights reserved.
Huang, Jian; Zhong, Zhaomin; Wang, Mingyong; Chen, Xifeng; Tan, Yicheng; Zhang, Shuqing; He, Wei; He, Xiong; Huang, Guodong; Lu, Haiping; Wu, Ping; Che, Yi; Yan, Yi-Lin; Postlethwait, John H.; Chen, Wenbiao
2015-01-01
Attention-deficit/hyperactivity disorder (ADHD) is one of the most prevalent psychiatric disorders in children and adults. While ADHD patients often display circadian abnormalities, the underlying mechanisms are unclear. Here we found that the zebrafish mutant for the circadian gene period1b (per1b) displays hyperactive, impulsive-like, and attention deficit-like behaviors and low levels of dopamine, reminiscent of human ADHD patients. We found that the circadian clock directly regulates dopamine-related genes monoamine oxidase and dopamine β hydroxylase, and acts via genes important for the development or maintenance of dopaminergic neurons to regulate their number and organization in the ventral diencephalic posterior tuberculum. We then found that Per1 knock-out mice also display ADHD-like symptoms and reduced levels of dopamine, thereby showing highly conserved roles of the circadian clock in ADHD. Our studies demonstrate that disruption of a circadian clock gene elicits ADHD-like syndrome. The circadian model for attention deficiency and hyperactive behavior sheds light on ADHD pathogenesis and opens avenues for exploring novel targets for diagnosis and therapy for this common psychiatric disorder. PMID:25673850
Meyer, Caroline; Leung, Newman; Barry, Letitia; De Feo, Danielle
2010-03-01
The aim of this study was to determine links between attitudes toward emotional expression and levels of eating psychopathology among young women. Eighty-nine young female volunteers completed the Attitudes Toward Emotional Expression scale (AEE) and the Eating Disorders Examination Questionnaire (EDEQ). There were positive significant associations between AEE subscales and EDEQ scores. In particular, those women who scored high on the EDEQ eating, shape, and weight subscales believe that to display emotion is a sign of weakness. Although those participants with high EDEQ weight concern scores were also likely to believe that they should keep their emotions under control and that others might be rejecting or damaged should they themselves display their emotions. These findings require replication with a clinical sample, however, they suggest that challenging these attitudes is potentially a useful step in facilitating acceptance of emotion and the development of adaptive emotion regulation strategies in those women with high levels of eating psychopathology.
Deakin, Janine E; Kruger-Andrzejewska, Maya
2016-09-01
Chromosome rearrangements have been implicated in diseases, such as cancer, and speciation, but it remains unclear whether rearrangements are causal or merely a consequence of these processes. Two marsupial families with very different rates of karyotype evolution provide excellent models in which to study the role of chromosome rearrangements in a disease and evolutionary context. The speciose family Dasyuridae displays remarkable karyotypic conservation, with all species examined to date possessing nearly identical karyotypes. Despite the seemingly high degree of chromosome stability within this family, they appear prone to developing tumours, including transmissible devil facial tumours. In contrast, chromosome rearrangements have been frequent in the evolution of the species-rich family Macropodidae, which displays a high level of karyotypic diversity. In particular, the genus Petrogale (rock-wallabies) displays an extraordinary level of chromosome rearrangement among species. For six parapatric Petrogale species, it appears that speciation has essentially been caught in the act, providing an opportunity to determine whether chromosomal rearrangements are a cause or consequence of speciation in this system. This review highlights the reasons that these two marsupial families are excellent models for testing hypotheses for hotspots of chromosome rearrangement and deciphering the role of chromosome rearrangements in disease and speciation.
NASA Technical Reports Server (NTRS)
Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.
2015-01-01
A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the development of DAA display performance standards, as well as the need for future research are discussed.
A spectrally tunable all-graphene-based flexible field-effect light-emitting device
NASA Astrophysics Data System (ADS)
Wang, Xiaomu; Tian, He; Mohammad, Mohammad Ali; Li, Cheng; Wu, Can; Yang, Yi; Ren, Tian-Ling
2015-07-01
The continuous tuning of the emission spectrum of a single light-emitting diode (LED) by an external electrical bias is of great technological significance as a crucial property in high-quality displays, yet this capability has not been demonstrated in existing LEDs. Graphene, a tunable optical platform, is a promising medium to achieve this goal. Here we demonstrate a bright spectrally tunable electroluminescence from blue (~450 nm) to red (~750 nm) at the graphene oxide/reduced-graphene oxide interface. We explain the electroluminescence results from the recombination of Poole-Frenkel emission ionized electrons at the localized energy levels arising from semi-reduced graphene oxide, and holes from the top of the π band. Tuning of the emission wavelength is achieved by gate modulation of the participating localized energy levels. Our demonstration of current-driven tunable LEDs not only represents a method for emission wavelength tuning but also may find applications in high-quality displays.
Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M
2012-01-01
In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.
The Alternative Worldview of State Religious High Schools in Israel.
ERIC Educational Resources Information Center
Ayalon, Hanna; Yogev, Abraham
1996-01-01
Analysis of school records of over 19,000 Israeli 12th graders revealed that secular and religious public high schools displayed different patterns of ethnic and gender inequality in distribution of students to higher-level humanities and science courses. Differing patterns of course taking are seemingly related to different views concerning the…
Highly Committed Teachers: What Makes Them Tick? A Study of Sustained Commitment
ERIC Educational Resources Information Center
Fransson, Göran; Frelin, Anneli
2016-01-01
This article focuses on teacher commitment, and particularly on teachers displaying sustained high levels of commitment throughout their teaching careers (over 15 years). Graduates from one Teacher Education programme responded to an open-ended questionnaire conducted on 10 occasions concerning their work as teachers, from graduation in 1993 to…
Comparison of 3D displays using objective metrics
NASA Astrophysics Data System (ADS)
Havig, Paul; McIntire, John; Dixon, Sharon; Moore, Jason; Reis, George
2008-04-01
Previously, we (Havig, Aleva, Reis, Moore, and McIntire, 2007) presented a taxonomy for the development of three-dimensional (3D) displays. We proposed three levels of metrics: objective (in which physical measurements are made of the display), subjective (Likert-type rating scales to show preferences of the display), and subjective-objective (performance metrics in which one shows how the 3D display may be more or less useful than a 2D display or a different 3D display). We concluded that for each level of metric, drawing practical comparisons among currently disparate 3D displays is difficult. In this paper we attempt to define more clearly the objective metrics for 3D displays. We set out to collect and measure physical attributes of several 3D displays and compare the results. We discuss our findings in terms of both difficulties in making the measurements in the first place, due to the physical set-up of the display, to issues in comparing the results we found and comparing how similar (or dissimilar) two 3D displays may or may not be. We conclude by discussing the next steps in creating objective metrics for three-dimensional displays as well as a proposed way ahead for the other two levels of metrics based on our findings.
Displaying uncertainty: investigating the effects of display format and specificity.
Bisantz, Ann M; Marsiglio, Stephanie Schinzing; Munch, Jessica
2005-01-01
We conducted four studies regarding the representation of probabilistic information. Experiments 1 through 3 compared performance on a simulated stock purchase task, in which information regarding stock profitability was probabilistic. Two variables were manipulated: display format for probabilistic information (blurred and colored icons, linguistic phrases, numeric expressions, and combinations) and specificity level (in which the number and size of discrete steps into which the probabilistic information was mapped differed). Results indicated few performance differences attributable to display format; however, performance did improve with greater specificity. Experiment 4, in which participants generated membership functions corresponding to three display formats, found a high degree of similarity in functions across formats and participants and a strong relationship between the shape of the membership function and the intended meaning of the representation. These results indicate that participants can successfully interpret nonnumeric representations of uncertainty and can use such representations in a manner similar to the way numeric expressions are used in a decision-making task. Actual or potential applications of this research include the use of graphical representations of uncertainty in systems such as command and control and situation displays.
Is meaning implicated in illusory conjunctions?
Virzi, R A; Egeth, H E
1984-08-01
According to feature-integration theory, when attention is diverted from a display, features from different objects in that display may be wrongly recombined, giving rise to "illusory conjunctions" (Treisman & Schmidt, 1982). Two experiments are reported that examine the nature of these illusory conjunctions. In displays that contain color names and adjectives printed in colored ink, subjects made two kinds of interesting and previously unreported errors. Consider, for example, a display that included the word BROWN in red ink and the word HEAVY in green ink. Subjects would sometimes incorrectly report that the word RED or the ink color brown had appeared in the display (e.g., RED in green ink or HEAVY in brown ink). It appears that subjects extract semantic representations from input and are sometimes confused about whether a particular representation has been extracted from a word or a color patch. Contrary to feature-integration theory, these findings suggest that illusory conjunctions may occur with high-level codes as well as with perceptual features.
NASA Technical Reports Server (NTRS)
Foyle, David C.
1993-01-01
Based on existing integration models in the psychological literature, an evaluation framework is developed to assess sensor fusion displays as might be implemented in an enhanced/synthetic vision system. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The pilot's performance with the sensor fusion image is compared to models' predictions based on the pilot's performance when viewing the original component sensor images prior to fusion. This allows for the determination as to when a sensor fusion system leads to: poorer performance than one of the original sensor displays, clearly an undesirable system in which the fused sensor system causes some distortion or interference; better performance than with either single sensor system alone, but at a sub-optimal level compared to model predictions; optimal performance compared to model predictions; or, super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays.
Geuijen, Cecilia A W; Clijsters-van der Horst, Marieke; Cox, Freek; Rood, Pauline M L; Throsby, Mark; Jongeneelen, Mandy A C; Backus, Harold H J; van Deventer, Els; Kruisbeek, Ada M; Goudsmit, Jaap; de Kruif, John
2005-07-01
Application of antibody phage display to the identification of cell surface antigens with restricted expression patterns is often complicated by the inability to demonstrate specific binding to a certain cell type. The specificity of an antibody can only be properly assessed when the antibody is of sufficient high affinity to detect low-density antigens on cell surfaces. Therefore, a robust and simple assay for the prediction of relative antibody affinities was developed and compared to data obtained using surface plasmon resonance (SPR) technology. A panel of eight anti-CD46 antibody fragments with different affinities was selected from phage display libraries and reformatted into complete human IgG1 molecules. SPR was used to determine K(D) values for these antibodies. The association and dissociation of the antibodies for binding to CD46 expressed on cell surfaces were analysed using FACS-based assays. We show that ranking of the antibodies based on FACS data correlates well with ranking based on K(D) values as measured by SPR and can therefore be used to discriminate between high- and low-affinity antibodies. Finally, we show that a low-affinity antibody may only detect high expression levels of a surface marker while failing to detect lower expression levels of this molecule, which may lead to a false interpretation of antibody specificity.
Flight tests of the 4D flight guidance display
NASA Astrophysics Data System (ADS)
Below, Christian; von Viebahn, Harro; Purpus, Matthias
1997-06-01
A perspective primary flight and a navigation display format were evaluated in a flying testbed. The flight tests comprised ILS- and standard approaches as well as low level operations utilizing the depiction of a spatial channel, and demonstrations of the inherent ground proximity warning function. In the cockpit of the VFW614, the left seat was equipped with a sidestick and a flat panel display, which showed both the 4D-display an the Navigation Display format. Airline and airforce pilots flew several missions each. Although most of the pilots criticizes that a typical flight director commanding the aircraft's attitude was missing, they could follow the channel precisely. However, some airline pilots stated a lack of vertical guidance information during the final approach. Leaving and re- entering the channel could be easily accomplished form any direction. In summary pilots' assessment of the display concept yielded an overall improvement of SA. In particular it was stated that displays are an appropriate means to avoid CFIT accidents. With the fist prototypes of 3D- graphics generators designed for avionics available the flight evaluation will continue including feasibility demonstrations of high-performance graphics for civil and military aircraft applications.
Proposed evaluation framework for assessing operator performance with multisensor displays
NASA Technical Reports Server (NTRS)
Foyle, David C.
1992-01-01
Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.
Negative quantum capacitance induced by midgap states in single-layer graphene.
Wang, Lin; Wang, Yang; Chen, Xiaolong; Zhu, Wei; Zhu, Chao; Wu, Zefei; Han, Yu; Zhang, Mingwei; Li, Wei; He, Yuheng; Xiong, Wei; Law, Kam Tuen; Su, Dangsheng; Wang, Ning
2013-01-01
We demonstrate that single-layer graphene (SLG) decorated with a high density of Ag adatoms displays the unconventional phenomenon of negative quantum capacitance. The Ag adatoms act as resonant impurities and form nearly dispersionless resonant impurity bands near the charge neutrality point (CNP). Resonant impurities quench the kinetic energy and drive the electrons to the Coulomb energy dominated regime with negative compressibility. In the absence of a magnetic field, negative quantum capacitance is observed near the CNP. In the quantum Hall regime, negative quantum capacitance behavior at several Landau level positions is displayed, which is associated with the quenching of kinetic energy by the formation of Landau levels. The negative quantum capacitance effect near the CNP is further enhanced in the presence of Landau levels due to the magnetic-field-enhanced Coulomb interactions.
Negative Quantum Capacitance Induced by Midgap States in Single-layer Graphene
Wang, Lin; Wang, Yang; Chen, Xiaolong; Zhu, Wei; Zhu, Chao; Wu, Zefei; Han, Yu; Zhang, Mingwei; Li, Wei; He, Yuheng; Xiong, Wei; Law, Kam Tuen; Su, Dangsheng; Wang, Ning
2013-01-01
We demonstrate that single-layer graphene (SLG) decorated with a high density of Ag adatoms displays the unconventional phenomenon of negative quantum capacitance. The Ag adatoms act as resonant impurities and form nearly dispersionless resonant impurity bands near the charge neutrality point (CNP). Resonant impurities quench the kinetic energy and drive the electrons to the Coulomb energy dominated regime with negative compressibility. In the absence of a magnetic field, negative quantum capacitance is observed near the CNP. In the quantum Hall regime, negative quantum capacitance behavior at several Landau level positions is displayed, which is associated with the quenching of kinetic energy by the formation of Landau levels. The negative quantum capacitance effect near the CNP is further enhanced in the presence of Landau levels due to the magnetic-field-enhanced Coulomb interactions. PMID:23784258
Bayer, Wibke; Tenbusch, Matthias; Lietz, Ruth; Johrden, Lena; Schimmer, Simone; Uberla, Klaus; Dittmer, Ulf; Wildner, Oliver
2010-02-01
We present a new type of adenoviral vector that both encodes and displays a vaccine antigen on the capsid, thus combining in itself gene-based and protein vaccination; this vector resulted in an improved vaccination outcome in the Friend virus (FV) model. For presentation of the envelope protein gp70 of Friend murine leukemia virus on the adenoviral capsid, gp70 was fused to the adenovirus capsid protein IX. When compared to vaccination with conventional FV Env- and Gag-encoding adenoviral vectors, vaccination with the adenoviral vector that encodes and displays pIX-gp70 combined with an FV Gag-encoding vector resulted in significantly improved protection against systemic FV challenge infection, with highly controlled viral loads in plasma and spleen. This improved protection correlated with improved neutralizing antibody titers and stronger CD4(+) T-cell responses. Using a vector that displays gp70 without encoding it, we found that while the antigen display on the capsid alone was sufficient to induce high levels of binding antibodies, in vivo expression was necessary for the induction of neutralizing antibodies. This new type of adenovirus-based vaccine could be a valuable tool for vaccination.
Development of intelligent monitoring purifier for indoor PM 2.5
NASA Astrophysics Data System (ADS)
Lou, Guanting; Zhu, Rong; Guo, Jiangwei; Wei, Yongqing
2018-03-01
The particulate matter 2.5 (PM2.5) refers to tiny particles or droplets in the air that are two and one half microns or less in width. PM2.5 is an air pollutant that is a concern for people’s health when levels in air are high. The intelligent monitoring purifier was developed to detect indoor PM2.5 concentration before and after purification and the monitoring data could be displayed on the LCD screen, displaying different color patterns according to the concentrations. Through the Bluetooth transport module, real-time values could also display on the mobile phone and voice broadcast PM2.5 concentration level in the air. When PM2.5 concentration is higher than the setting threshold, the convection fan rotation and the speed can be remote controlled with mobile phone through the Bluetooth transport. Therefore, the efficiency and scope of the purification could be enhanced and further better air quality could be achieved.
A Flexible Approach for the Statistical Visualization of Ensemble Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potter, K.; Wilson, A.; Bremer, P.
2009-09-29
Scientists are increasingly moving towards ensemble data sets to explore relationships present in dynamic systems. Ensemble data sets combine spatio-temporal simulation results generated using multiple numerical models, sampled input conditions and perturbed parameters. While ensemble data sets are a powerful tool for mitigating uncertainty, they pose significant visualization and analysis challenges due to their complexity. We present a collection of overview and statistical displays linked through a high level of interactivity to provide a framework for gaining key scientific insight into the distribution of the simulation results as well as the uncertainty associated with the data. In contrast to methodsmore » that present large amounts of diverse information in a single display, we argue that combining multiple linked statistical displays yields a clearer presentation of the data and facilitates a greater level of visual data analysis. We demonstrate this approach using driving problems from climate modeling and meteorology and discuss generalizations to other fields.« less
de Mestral, L G; Herbinger, C M
2013-11-01
Behaviour trials determining antipredator response were conducted on first and second generation juveniles from a captive breeding and rearing programme for endangered Inner Bay of Fundy Atlantic salmon Salmo salar. Second generation captive fry displayed significantly higher levels of risk-taking behaviour before and after exposure to a simulated avian predator. Because the first and second generation fry were reared under the same environmental conditions and differed only in the number of generations spent in captivity, these results suggest that rapid genetic changes, possibly due to domestication selection, may have occurred. Antipredator response was also assessed in fully wild and highly domesticated experimental groups: wild fry displayed the greatest antipredator response and domesticated fry displayed the highest levels of risk-taking behaviour. These results add to the growing evidence documenting rapid genetic change in response to rearing in a captive environment. © 2013 The Fisheries Society of the British Isles.
NASA Astrophysics Data System (ADS)
Nichols, Jonathan A.
Organic light-emitting diode (OLED) displays are of immense interest because they have several advantages over liquid crystal displays, the current dominant flat panel display technology. OLED displays are emissive and therefore are brighter, have a larger viewing angle, and do not require backlights and filters, allowing thinner, lighter, and more power efficient displays. The goal of this work was to advance the state-of-the-art in active-matrix OLED display technology. First, hydrogenated amorphous silicon (a-Si:H) thin film transistor (TFT) active-matrix OLED pixels and arrays were designed and fabricated on glass substrates. The devices operated at low voltages and demonstrated that lower performance TFTs could be utilized in active-matrix OLED displays, possibly allowing lower cost processing and the use of polymeric substrates. Attempts at designing more control into the display at the pixel level were also made. Bistable (one bit gray scale) active-matrix OLED pixels and arrays were designed and fabricated. Such pixels could be used in novel applications and eventually help reduce the bandwidth requirements in high-resolution and large-area displays. Finally, a-Si:H TFT active-matrix OLED pixels and arrays were fabricated on a polymeric substrate. Displays fabricated on a polymeric substrates would be lightweight; flexible, more rugged, and potentially less expensive to fabricate. Many of the difficulties associated with fabricating active-matrix backplanes on flexible substrates were studied and addressed.
Online single particle measurement of fireworks pollution during Chinese New Year in Nanning.
Li, Jingyan; Xu, Tingting; Lu, Xiaohui; Chen, Hong; Nizkorodov, Sergey A; Chen, Jianmin; Yang, Xin; Mo, Zhaoyu; Chen, Zhiming; Liu, Huilin; Mao, Jingying; Liang, Guiyun
2017-03-01
Time-resolved single-particle measurements were conducted during Chinese New Year in Nanning, China. Firework displays resulted in a burst of SO 2 , coarse mode, and accumulation mode (100-500nm) particles. Through single particle mass spectrometry analysis, five different types of particles (fireworks-metal, ash, dust, organic carbon-sulfate (OC-sulfate), biomass burning) with different size distributions were identified as primary emissions from firework displays. The fireworks-related particles accounted for more than 70% of the total analyzed particles during severe firework detonations. The formation of secondary particulate sulfate and nitrate during firework events was investigated on single particle level. An increase of sulfite peak (80SO 3 - ) followed by an increase of sulfate peaks (97HSO 4 - +96SO 4 - ) in the mass spectra during firework displays indicated the aqueous uptake and oxidation of SO 2 on particles. High concentration of gaseous SO 2 , high relative humidity and high particle loading likely promoted SO 2 oxidation. Secondary nitrate formed through gas-phase oxidation of NO 2 to nitric acid, followed by the condensation into particles as ammonium nitrate. This study shows that under worm, humid conditions, both primary and secondary aerosols contribute to the particulate air pollution during firework displays. Copyright © 2016. Published by Elsevier B.V.
Fernandez, Gimena; Cabral, Agustina; Andreoli, María F; Labarthe, Alexandra; M'Kadmi, Céline; Ramos, Jorge G; Marie, Jacky; Fehrentz, Jean-Alain; Epelbaum, Jacques; Tolle, Virginie; Perello, Mario
2018-02-01
Ghrelin is a potent orexigenic peptide hormone that acts through the growth hormone secretagogue receptor (GHSR), a G protein-coupled receptor highly expressed in the hypothalamus. In vitro studies have shown that GHSR displays a high constitutive activity, whose physiological relevance is uncertain. As GHSR gene expression in the hypothalamus is known to increase in fasting conditions, we tested the hypothesis that constitutive GHSR activity at the hypothalamic level drives the fasting-induced hyperphagia. We found that refed wild-type (WT) mice displayed a robust hyperphagia that continued for 5 days after refeeding and changed their food intake daily pattern. Fasted WT mice showed an increase in plasma ghrelin levels, as well as in GHSR expression levels and ghrelin binding sites in the hypothalamic arcuate nucleus. When fasting-refeeding responses were evaluated in ghrelin- or GHSR-deficient mice, only the latter displayed an ∼15% smaller hyperphagia, compared with WT mice. Finally, fasting-induced hyperphagia of WT mice was significantly smaller in mice centrally treated with the GHSR inverse agonist K-(D-1-Nal)-FwLL-NH2, compared with mice treated with vehicle, whereas it was unaffected in mice centrally treated with the GHSR antagonists D-Lys3-growth hormone-releasing peptide 6 or JMV2959. Taken together, genetic models and pharmacological results support the notion that constitutive GHSR activity modulates the magnitude of the compensatory hyperphagia triggered by fasting. Thus, the hypothalamic GHSR signaling system could affect the set point of daily food intake, independently of plasma ghrelin levels, in situations of negative energy balance. Copyright © 2018 Endocrine Society.
Constancy of built-in luminance meter measurements in diagnostic displays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M.
2013-12-15
Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49 336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25 000 BLH and those with more than 25 000 BLH. Bias between meters was also evaluated.more » Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35 000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25 000 and greater than 25 000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35 000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.« less
Education Outside of the Box: Homeschooling Your Gifted or Twice-Exceptional Child
ERIC Educational Resources Information Center
Goodwin, Corin Barsily; Gustavson, Mika
2012-01-01
Gifted children are children first, and they have educational and social-emotional needs that run all over the map. Anyone who knows gifted children is familiar with the sudden shifts within a child who might be doing high school level scientific study, handwriting at a third grade level, display the wit and wisdom of a middle aged adult, and…
Reading comprehension in Parkinson's disease.
Murray, Laura L; Rutledge, Stefanie
2014-05-01
Although individuals with Parkinson's disease (PD) self-report reading problems and experience difficulties in cognitive-linguistic functions that support discourse-level reading, prior research has primarily focused on sentence-level processing and auditory comprehension. Accordingly, the authors investigated the presence and nature of reading comprehension in PD, hypothesizing that (a) individuals with PD would display impaired accuracy and/or speed on reading comprehension tests and (b) reading performances would be correlated with cognitive test results. Eleven adults with PD and 9 age- and education-matched control participants completed tests that evaluated reading comprehension; general language and cognitive abilities; and aspects of attention, memory, and executive functioning. The PD group obtained significantly lower scores on several, but not all, reading comprehension, language, and cognitive measures. Memory, language, and disease severity were significantly correlated with reading comprehension for the PD group. Individuals in the early stages of PD without dementia or broad cognitive deficits can display reading comprehension difficulties, particularly for high- versus basic-level reading tasks. These reading difficulties are most closely related to memory, high-level language, and PD symptom severity status. The findings warrant additional research to delineate further the types and nature of reading comprehension impairments experienced by individuals with PD.
Pixel-level tunable liquid crystal lenses for auto-stereoscopic display
NASA Astrophysics Data System (ADS)
Li, Kun; Robertson, Brian; Pivnenko, Mike; Chu, Daping; Zhou, Jiong; Yao, Jun
2014-02-01
Mobile video and gaming are now widely used, and delivery of a glass-free 3D experience is of both research and development interest. The key drawbacks of a conventional 3D display based on a static lenticular lenslet array and parallax barriers are low resolution, limited viewing angle and reduced brightness, mainly because of the need of multiple-pixels for each object point. This study describes the concept and performance of pixel-level cylindrical liquid crystal (LC) lenses, which are designed to steer light to the left and right eye sequentially to form stereo parallax. The width of the LC lenses can be as small as 20-30 μm, so that the associated auto-stereoscopic display will have the same resolution as the 2D display panel in use. Such a thin sheet of tunable LC lens array can be applied directly on existing mobile displays, and can deliver 3D viewing experience while maintaining 2D viewing capability. Transparent electrodes were laser patterned to achieve the single pixel lens resolution, and a high birefringent LC material was used to realise a large diffraction angle for a wide field of view. Simulation was carried out to model the intensity profile at the viewing plane and optimise the lens array based on the measured LC phase profile. The measured viewing angle and intensity profile were compared with the simulation results.
Lephart, Edwin D
2017-06-03
Phytochemicals are botanical compounds used in dermatology applications as cosmeceuticals to improve skin health. Resveratrol and equol are two of the best-known polyphenolic or phytoestrogens having similar chemical structures and some overlapping biological functions to 17β-estradiol. Human skin gene expression was reviewed for 28 different biomarkers when resveratrol, 4' acetoxy resveratrol (4AR), R -equol, racemic equol or S -equol were tested. Sirtuin 1 activator (SIRT 1) was stimulated by resveratrol and 4AR only. Resveratrol, R -equol and racemic equol were effective on the aging biomarkers proliferating cell nuclear factor (PCNA), nerve growth factor (NGF), 5α-reductase and the calcium binding proteins S100 A8 and A9. Racemic equol and 4AR displayed among the highest levels for the collagens, elastin and tissue inhibitor of the matrix metalloproteinase 1 (TIMP 1). S -equol displayed the lowest level of effectiveness compared to the other compounds. The 4AR analog was more effective compared to resveratrol by 1.6-fold. R -equol and racemic equol were almost equal in potency displaying greater inhibition vs. resveratrol or its 4' analog for the matrix metalloproteinases (MMPs), but among the inflammatory biomarkers, resveratrol, 4AR, R -equol and racemic equol displayed high inhibition. Thus, these cosmeceuticals display promise to improve dermal health; however, further study is warranted to understand how phytochemicals protect/enhance the skin.
Experimental Studies of Intent Information on Cockpit Traffic Displays
NASA Technical Reports Server (NTRS)
Barhydt, Richard; Hansman, R. John, Jr.
1997-01-01
Intent information provides knowledge of another aircraft's current and future trajectory states. Prototype traffic displays were designed for four different levels of intent: No Intent, Rate, Commanded State, and Flight Management System (FMS)-Path. The TCAS Display was used as a baseline and represents the No Intent Level. The Rate, Commanded State, and FMS-Path Displays show increasing levels of intent information using TCAS-like symbology in addition to incorporating a conflict probe and profile view display. An experiment was run on the MIT Part Task Flight Simulator in which eight airline pilots flew five traffic scenarios with each of the four displays. Results show that pilots had fewer separation violations and maneuvered earlier with the three intent displays. Separation violations were reduced when pilots maneuvered earlier. A second experiment was run to compare performance between displaying intent information directly and incorporating it into a conflict probe. A different set of eight airline pilots flew four traffic scenarios with the TCAS and Commanded State Displays with and without the conflict probe. Conflict probes with two minute and long range look-ahead times were tested. Displaying conflict bands or showing intent information directly both led to fewer separation violations and earlier avoidance maneuvers than the base TCAS Display. Performance was similar between the two minute and long range look-ahead conflict probes. Pilots preferred all intent displays over the TCAS Display.
Isolation of stress responsive Psb A gene from rice (Oryza sativa l.) using differential display.
Tyagi, Aruna; Chandra, Arti
2006-08-01
Differential display (DD) experiments were performed on drought-tolerant rice (Oryza sativa L.) genotype N22 to identify both upregulated and downregulated partial cDNAs with respect to moisture stress. DNA polymorphism was detected between drought-stressed and control leaf tissues on the DD gels. A partial cDNA showing differential expression, with respect to moisture stress was isolated from the gel. Northern blotting analysis was performed using this cDNA as a probe and it was observed that mRNA corresponding to this transcript was accumulated to high level in rice leaves under water deficit stress. At the DNA sequence level, the partial cDNA showed homology with psb A gene encoding for Dl protein.
NASA Astrophysics Data System (ADS)
Bartolone, Anthony P.; Glaab, Louis J.; Hughes, Monica F.; Parrish, Russell V.
2005-05-01
Synthetic Vision Systems (SVS) displays provide pilots with a continuous view of terrain combined with integrated guidance symbology in an effort to increase situation awareness (SA) and decrease workload during operations in Instrument Meteorological Conditions (IMC). It is hypothesized that SVS displays can replicate the safety and operational flexibility of flight in Visual Meteorological Conditions (VMC), regardless of actual out-the-window (OTW) visibility or time of day. Throughout the course of recent SVS research, significant progress has been made towards evolving SVS displays as well as demonstrating their ability to increase SA compared to conventional avionics in a variety of conditions. While a substantial amount of data has been accumulated demonstrating the capabilities of SVS displays, the ability of SVS to replicate the safety and operational flexibility of VMC flight performance in all visibility conditions is unknown to any specific degree. The previous piloted simulations and flight tests have shown better SA and path precision is achievable with SVS displays without causing an increase in workload, however none of the previous SVS research attempted to fully capture the significance of SVS displays in terms of their contribution to safety or operational benefits. In order to more fully quantify the relationship of flight operations in IMC with SVS displays to conventional operations conducted in VMC, a fundamental comparison to current day general aviation (GA) flight instruments was warranted. Such a comparison could begin to establish the extent to which SVS display concepts are capable of maintaining an "equivalent level of safety" with the round dials they could one day replace, for both current and future operations. Such a comparison was the focus of the SVS-ES experiment conducted under the Aviation Safety and Security Program's (AvSSP) GA Element of the SVS Project at NASA Langley Research Center in Hampton, Virginia. A combination of subjective and objective data measures were used in this preliminary research to quantify the relationship between selected components of safety that are associated with flying an approach. Four information display methods ranging from a "round dials" baseline through a fully integrated SVS package that includes terrain, pathway based guidance, and a strategic navigation display, were investigated in this high fidelity simulation experiment. In addition, a broad spectrum of pilots, representative of the GA population, were employed for testing in an attempt to enable greater application of the results and determine if "equivalent levels of safety" are achievable through the incorporation of SVS technology regardless of a pilot's flight experience.
Solving bezel reliability and CRT obsolescence
NASA Astrophysics Data System (ADS)
Schwartz, Richard J.; Bowen, Arlen R.; Knowles, Terry
2003-09-01
Scientific Research Corporation designed a Smart Multi-Function Color Display with Positive Pilot Feedback under the funding of an U. S. Navy Small Business Innovative Research program. The Smart Multi-Function Color Display can replace the obsolete monochrome Cathode Ray Tube display currently on the T-45C aircraft built by Boeing. The design utilizes a flat panel color Active Matrix Liquid Crystal Display and TexZec's patented Touch Thru Metal bezel technology providing both visual and biomechanical feedback to the pilot in a form, fit, and function replacement to the current T-45C display. Use of an existing color AMLCD, requires the least adaptation to fill the requirements of this application, thereby minimizing risk associated with developing a new display technology and maximizing the investment in improved user interface technology. The improved user interface uses TexZec's Touch Thru Metal technology to eliminate all of the moving parts that traditionally have limited Mean-Time-Between-Failure. The touch detection circuit consists of Commercial-Off-The-Shelf components, creating touch detection circuitry, which is simple and durable. This technology provides robust switch activation and a high level of environmental immunity, both mechanical and electrical. Replacement of all the T-45C multi-function displays with this design will improve the Mean-Time-Between-Failure and drastically reduce display life cycle costs. The design methodology described in this paper can be adapted to any new or replacement display.
NASA Astrophysics Data System (ADS)
Good, Walter F.; Herron, John M.; Maitz, Glenn S.; Gur, David; Miller, Stephen L.; Straub, William H.; Fuhrman, Carl R.
1990-08-01
We designed and implemented a high-resolution video workstation as the central hardware component in a comprehensive multi-project program comparing the use of digital and film modalities. The workstation utilizes a 1.8 GByte real-time disk (RCI) capable of storing 400 full-resolution images and two Tektronix (GMA251) display controllers with 19" monitors (GMA2O2). The display is configured in a portrait format with a resolution of 1536 x 2048 x 8 bit, and operates at 75 Hz in a noninterlaced mode. Transmission of data through a 12 to 8 bit lookup table into the display controllers occurs at 20 MBytes/second (.35 seconds per image). The workstation allows easy use of brightness (level) and contrast (window) to be manipulated with a trackball, and various processing options can be selected using push buttons. Display of any of the 400 images is also performed at 20MBytes/sec (.35 sec/image). A separate text display provides for the automatic display of patient history data and for a scoring form through which readers can interact with the system by means of a computer mouse. In addition, the workstation provides for the randomization of cases and for the immediate entry of diagnostic responses into a master database. Over the past year this workstation has been used for over 10,000 readings in diagnostic studies related to 1) image resolution; 2) film vs. soft display; 3) incorporation of patient history data into the reading process; and 4) usefulness of image processing.
EZStream: Distributing Live ISS Experiment Telemetry via Internet
NASA Technical Reports Server (NTRS)
Myers, Gerry; Welch, Clara L. (Technical Monitor)
2002-01-01
This paper will present the high-level architecture and components of the current version of EZStream as well as the product direction & enhancements to be incorporated through a Phase II grant. Security will be addressed such as data encryption and user login. Remote user devices will be discussed including web browsers on PC's and displays on PDA's and smart cell phones. The interaction between EZStream and TReK will be covered as well as the eventuality of EZStream to receive and parse binary data streams directly. This makes EZStream beneficial to both the International Partners and non-NASA applications. The options of developing client-side display web pages will be addressed and the development of new tools to allow creation of display web pages by non-programmers.
Bonomo, Maria Grazia; Sico, Maria Anna; Grieco, Simona; Salzano, Giovanni
2009-01-01
Lactobacillus sakei is widely used as starter in the production process of Italian fermented sausages and its growth and survival are affected by various factors. We studied the differential expression of genome in response to different stresses by the fluorescent differential display (FDD) technique. This study resulted in the development and optimization of an innovative technique, with a high level of reproducibility and quality, which allows the identification of gene expression changes associated with different microbial behaviours under different growth conditions. PMID:22253979
A database system to support image algorithm evaluation
NASA Technical Reports Server (NTRS)
Lien, Y. E.
1977-01-01
The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.
Influence of high ambient illuminance and display luminance on readability and subjective preference
NASA Astrophysics Data System (ADS)
De Moor, Katrien; Andrén, Börje; Guo, Yi; Brunnström, Kjell; Wang, Kun; Drott, Anton; Hermann, David S.
2015-03-01
Many devices, such as tablets, smartphones, notebooks, fixed and portable navigation systems are used on a (nearly) daily basis, both in in- and outdoor environments. It is often argued that contextual factors, such as the ambient illuminance in relation to characteristics of the display (e.g., surface treatment, screen reflectance, display luminance …) may have a strong influence on the use of such devices and corresponding user experiences. However, the current understanding of these influence factors is still rather limited. In this work, we therefore focus in particular on the impact of lighting and display luminance on readability, visual performance, subjective experience and preference. A controlled lab study (N=18) with a within-subjects design was performed to evaluate two car displays (one glossy and one matte display) in conditions that simulate bright outdoor lighting conditions. Four ambient luminance levels and three display luminance settings were combined into 7 experimental conditions. More concretely, we investigated for each display: (1) whether and how readability and visual performance varied with the different combinations of ambient luminance and display luminance and (2) whether and how they influenced the subjective experience (through self-reported valence, annoyance, visual fatigue) and preference. The results indicate a limited, yet negative influence of increased ambient luminance and reduced contrast on visual performance and readability for both displays. Similarly, we found that the self-reported valence decreases and annoyance and visual fatigue increase as the contrast ratio decreases and ambient luminance increases. Overall, the impact is clearer for the matte display than for the glossy display.
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. (a) Electronic display..., considering the expected electronic display brightness level at the end of an electronic display indictor's...
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. (a) Electronic display..., considering the expected electronic display brightness level at the end of an electronic display indictor's...
14 CFR 23.1311 - Electronic display instrument systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electronic display instrument systems. 23... Equipment Instruments: Installation § 23.1311 Electronic display instrument systems. (a) Electronic display..., considering the expected electronic display brightness level at the end of an electronic display indictor's...
72-directional display having VGA resolution for high-appearance image generation
NASA Astrophysics Data System (ADS)
Takaki, Yasuhiro; Dairiki, Takeshi
2006-02-01
The high-density directional display, which was originally developed in order to realize a natural 3D display, is not only a 3D display but also a high-appearance display. The appearances of objects, such as glare and transparency, are the results of the reflection and the refraction of rays. The faithful reproduction of such appearances of objects is impossible using conventional 2D displays because rays diffuse on the display screen. The high-density directional display precisely controls the horizontal ray directions so that it can reproduce the appearances of objects. The fidelity of the reproduction of object appearances depends on the ray angle sampling pitch. The angle sampling pitch is determined by considering the human eye imaging system. In the present study the high-appearance display which has the resolution of 640×400 and emits rays in 72 different horizontal directions with the angle pitch of 0.38° was constructed. Two 72-directional displays were combined, each of which consisted of a high-resolution LCD panel (3,840×2,400) and a slanted lenticular sheet. Two images produced by two displays were superimposed by a half mirror. A slit array was placed at the focal plane of the lenticular sheet for each display to reduce the horizontal image crosstalk in the combined image. The impression analysis shows that the high-appearance display provides higher appearances and presence than the conventional 2D displays do.
Developing a High Level Data Base to Teach Reproductive Endocrinology Using the HyperCard Program.
ERIC Educational Resources Information Center
Friedler, Yael; Shabo, Amnon
1990-01-01
Describes a database courseware using the HyperCard program on the subject of human reproductive endocrinology and feedback mechanisms. Discusses some issues concerning database courseware development. Presents several examples of the courseware display. (Author/YP)
NASA Astrophysics Data System (ADS)
Dupré, Ludovic; Marra, Marjorie; Verney, Valentin; Aventurier, Bernard; Henry, Franck; Olivier, François; Tirano, Sauveur; Daami, Anis; Templier, François
2017-02-01
We report the fabrication process and characterization of high resolution 873 x 500 pixels emissive arrays based on blue or green GaN/InGaN light emitting diodes (LEDs) at a reduced pixel pitch of 10 μm. A self-aligned process along with a combination of damascene metallization steps is presented as the key to create a common cathode which is expected to provide good thermal dissipation and prevent voltage drops between center and side of the micro LED matrix. We will discuss the challenges of a self-aligned technology related to the choice of a good P contact metal and will present our solutions for the realization of the metallic interconnections between the GaN contacts and the higher levels of metallization at such a small pixel pitch. Enhanced control of each technological step allows scalability of the process up to 4 inch LED wafers and production of high quality LED arrays. The very high brightness (up to 107 cd.m-2) and good external quantum efficiency (EQE) of the resulting device make these kind of micro displays suitable for augmented reality or head up display applications.
Chapela, Patricia J; Broaddus, Russell R; Hawkins, Shannon M; Lessey, Bruce A; Carson, Daniel D
2015-11-01
MUC4, a transmembrane glycoprotein, interferes with cell adhesion, and promotes EGFR signaling in cancer. Studies in rat models have demonstrated steroid hormonal regulation of endometrial MUC4 expression. In this study, qRT-PCR screening of mouse tissues determined that Muc4 mRNA also was robustly expressed in mouse uteri. Previous studies from our labs have demonstrated MUC4 mRNA was expressed at levels <1% of MUC1 mRNA in human endometrium and endometriotic tissue. Multiple human endometrial adenocarcinoma cell lines were assayed for MUC4 mRNA expression revealing extremely low basal expression in the Ishikawa, RL-95-2, AN3CA, and KLE lines. Moderate to high expression was observed in HEC50 and HEC-1A cells. MUC4 mRNA expression was not affected by progesterone and/or estrogen treatment, but was greatly stimulated at both mRNA and protein levels by proinflammatory cytokines (IFN-γ and TNF-α), particularly when used in combination. In endometrial tissue, MUC4 mRNA levels did not change significantly between normal or cancerous samples; although, a subset of patients with grade 1 and 2 tumors displayed substantially higher expression. Likewise, immunostaining of human endometrial adenocarcinoma tissues revealed little to no staining in many patients (low MUC4), but strong staining in some patients (high MUC4) independent of cancer grade. In cases where staining was observed, it was heterogeneous with some cells displaying robust MUC4 expression and others displaying little or no staining. Collectively, these observations demonstrate that while MUC4 is highly expressed in the mouse uterus, it is not a major mucin in normal human endometrium. Rather, MUC4 is a potential marker of endometrial adenocarcinoma in a subset of patients. © 2015 Wiley Periodicals, Inc.
Experimental Studies of the Effect of Intent Information on Cockpit Traffic Displays
NASA Technical Reports Server (NTRS)
Barhydt, Richard; Hansman, R. John
1997-01-01
Intent information provides knowledge of another aircraft's current and future trajectory states. Prototype traffic displays were designed for four different levels of intent: Position, Rate, Commanded State, and FMS (Flight Management System)-Path. The current TCAS (traffic collision avoidance systems) Display, which shows altitude rate in addition to current position and altitude, was used as a baseline and represents the lowest level of intent. The Rate, Commanded State, and FMS-Path Displays show increasing levels of intent information using TCAS-like symbology in addition to incorporating a conflict probe and profile view display. An initial experiment was run on the MIT (Massachusetts Institute of Technology) Part Task Flight Simulator in which eight airline pilots flew five traffic scenarios with each of the four displays. Results show that pilots had fewer separation violations and maneuvered earlier with the three intent displays. Separation violations were reduced when pilots maneuvered earlier. A second experiment was run to compare performance between displaying intent information directly and incorporating it into a conflict probe. A different set of eight airline pilots flew four traffic scenarios with the TCAS and Commanded State Displays with and without the conflict probe. Conflict probes with two minute and long range look-ahead times were tested. Displaying conflict bands or showing intent information directly both led to fewer separation violations and earlier avoidance maneuvers than the base TCAS Display. Performance was similar between the two minute and long range look-ahead conflict probes. Pilots preferred all intent displays over the TCAS Display.
Universal Power Law of the Gravity Wave Manifestation in the AIM CIPS Polar Mesospheric Cloud Images
NASA Astrophysics Data System (ADS)
Rong, P. P.; Yue, J.; Russell, J. M., III; Siskind, D. E.; Randall, C. E.
2017-12-01
A large ensemble of gravity waves (GWs) resides in the PMCs and we aim to extract the universal law that governs the wave display throughout the GW population. More specifically, we examined how wave display morphology and clarity level varies throughout the wave population manifested through the PMC albedo data. Higher clarity refers to more distinct exhibition of the features which often correspond to larger variances and better organized nature. A gravity wave tracking algorithm is designed and applied to the PMC albedo data taken by the AIM Cloud Imaging and Particle Size (CIPS) instrument to obtain the gravity wave detections throughout the two northern summers in 2007 and 2010. The horizontal wavelengths in the range of 20-60km are the focus of the study because they are the most commonly observed and readily captured in the CIPS orbital strips. A 1-dimensional continuous wavelet transform (CWT) is applied to PMC albedo along all radial directions within an elliptical region that has a radius of 400 km and an axial ratio of 0.65. The center of the elliptical region moves around the CIPS orbital strips so that waves at different locations and orientations can be captured. It shows that the CWT albedo power statistically increases as the background gets brighter. We resample the wave detections to conform to a normal distribution via removing the dependence of the albedo power on the background cloud brightness because we tend to examine the wave morphology beyond the cloud brightness impact. Sample cases are selected at the two tails and the peak of the normal distribution, and at three brightness levels, to represent the high, medium, and low albedo power categories. For these cases the albedo CWT power spectra follow exponential decay toward smaller scales. The high albedo power has the most rapid decay (i.e., exponent=-3.2) and corresponds to the most distinct wave display. Overall higher albedo power and more rapid decay both contributed to the more distinct display. The wave display becomes increasingly more blurry for the medium and low power categories that hold the exponents of -2.9 and -2.5, respectively. The majority of waves are straight waves whose clarity levels can be collapsed irrespective of the brightness levels but in the brighter background the wave signatures seem to exhibit mildly turbulent-like behavior.
ERIC Educational Resources Information Center
Sia, Ding Teng; Treagust, David F.; Chandrasegaran, A. L.
2012-01-01
This study was conducted with 330 Form 4 (grade 10) students (aged 15-16 years) who were involved in a course of instruction on electrolysis concepts. The main purposes of this study were (1) to assess high school chemistry students' understanding of 19 major principles of electrolysis using a recently developed 2-tier multiple-choice diagnostic…
ERIC Educational Resources Information Center
Wells, Casey L.
2012-01-01
The effect of electronic books on the reading comprehension of middle and high school students was examined using an experimental posttest-only control-group design. A convenience sample of 140 randomly assigned middle and high school English students at an independent school in eastern North Carolina participated. Half of the students used…
Aesthetic Leadership Perceptions of High School Students Regarding Their Teachers
ERIC Educational Resources Information Center
Güven, Ejder; Polat, Soner
2016-01-01
The aim of this study is to examine the high school students? level of perception related to aesthetic leadership and its sub-dimensions and try to identify the characteristics of aesthetic leadership that have been displayed by their teachers in Kocaeli, Turkey. In this research, mixed research model has been adopted. At the end of the research,…
Baird, Troy A; Lovern, Matthew B; Shine, Richard
2014-07-01
Water dragons (Intellegama [Physignathus] lesueurii) are large (to >1m) agamid lizards from eastern Australia. Males are fiercely combative; holding a territory requires incessant displays and aggression against other males. If a dominant male is absent, injured or fatigued, another male soon takes over his territory. Our sampling of blood from free-ranging adult males showed that baseline levels of both testosterone and corticosterone were not related to a male's social tactic (territorial versus non-territorial), or his frequency of advertisement display, aggression, or courtship behavior. Even when we elicited intense aggression by non-territorial males (by temporarily removing territory owners), testosterone did not increase with the higher levels of aggression that ensued. Indeed, testosterone levels decreased in males that won contests. In contrast, male corticosterone levels increased with the heightened aggression during unsettled conditions, and were higher in males that won contests. High chronic male-male competition in this dense population may favor high testosterone levels in all adult males to facilitate advertisement and patrol activities required for territory maintenance (by dominant animals), and to maintain readiness for territory take-overs (in non-territorial animals). Corticosterone levels increased in response to intense aggression during socially unstable conditions, and were higher in contest winners than losers. A positive correlation between the two hormones during socially unstable conditions suggests that the high stress of contests decreased androgen production. The persistent intense competition in this population appears to exact a high physiological cost, which together with our observation that males sometimes lose their territories to challengers may indicate cycling between these two tactics to manage long-term energetic costs. Copyright © 2014 Elsevier Inc. All rights reserved.
Validation of Minimum Display Requirements for a UAS Detect and Avoid System
NASA Technical Reports Server (NTRS)
Rorie, Conrad; Fern, Lisa; Roberts, Zach; Monk, Kevin; Santiago, Confesor; Shively, Jay
2017-01-01
The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to see and avoid other aircraft in order to maintain well clear. The present study is the final in a series of human-in-the-loop experiments designed to explore and test the various display and alerting requirements being incorporated into the minimum operational performance standards (MOPS) for a UAS-specific detect and avoid system that would replace the see and avoid function required of manned aircraft. Two display configurations were tested - an integrated display and a standalone display - and their impact on pilot response times and ability to maintain DAA well clear were compared. Results indicated that the current draft of the MOPS result in high-level performance and did not meaningfully differ by display configuration.
Acute Exposure of College Basketball Players to Moderate Altitude: Selected Physiological Responses.
ERIC Educational Resources Information Center
Noble, Bruce J.; Maresh, Carl M.
1979-01-01
In general, basketball players with moderately high aerobic power who reside at an altitude of 1,000 m do not display the hypoxic response to an altitude of 2,200 m expected of sea level residents and aerobically trained athletes. (JD)
A spectrally tunable all-graphene-based flexible field-effect light-emitting device
Wang, Xiaomu; Tian, He; Mohammad, Mohammad Ali; Li, Cheng; Wu, Can; Yang, Yi; Ren, Tian-Ling
2015-01-01
The continuous tuning of the emission spectrum of a single light-emitting diode (LED) by an external electrical bias is of great technological significance as a crucial property in high-quality displays, yet this capability has not been demonstrated in existing LEDs. Graphene, a tunable optical platform, is a promising medium to achieve this goal. Here we demonstrate a bright spectrally tunable electroluminescence from blue (∼450 nm) to red (∼750 nm) at the graphene oxide/reduced-graphene oxide interface. We explain the electroluminescence results from the recombination of Poole–Frenkel emission ionized electrons at the localized energy levels arising from semi-reduced graphene oxide, and holes from the top of the π band. Tuning of the emission wavelength is achieved by gate modulation of the participating localized energy levels. Our demonstration of current-driven tunable LEDs not only represents a method for emission wavelength tuning but also may find applications in high-quality displays. PMID:26178323
Longevity factor klotho and chronic psychological stress
Prather, A A; Epel, E S; Arenander, J; Broestl, L; Garay, B I; Wang, D; Dubal, D B
2015-01-01
Chronic psychological stress is associated with accelerated aging and premature morbidity and mortality; however, the biology linking chronic psychological stress and its maladaptive effects remains largely unknown. Klotho is a pleiotropic hormone that regulates the aging process and promotes better brain and body health. Whether klotho is linked to psychosocial stress or its negative impact in humans has not been investigated. To address this gap, we recruited 178 healthy women who were either chronically high-stress maternal caregivers for a child with autism spectrum disorder (n=90) or low-stress control mothers of a typically developing child (n=88). We found that women under high chronic stress displayed significantly lower levels of the longevity hormone klotho compared with low-stress controls (t(176)=2.92, P=0.004; d=0.44), and the decrease among those under high stress was age-dependent. In addition, high-stress caregivers who reported more depressive symptoms displayed even lower klotho levels compared with low-stress participants. These findings provide the first evidence that klotho levels are sensitive to psychosocial stressors and raise the possibility that klotho may serve as a novel biological link connecting stress, depression and risk for accelerated disease development. Furthermore, these findings have important implications for understanding the plasticity of the aging process and may represent a therapeutic target for mitigating the deleterious effects of chronic psychological stress on health and well-being. PMID:26080320
Active matrix organic light emitting diode (OLED)-XL life test results
NASA Astrophysics Data System (ADS)
Fellowes, David A.; Wood, Michael V.; Hastings, Arthur R., Jr.; Ghosh, Amalkumar P.; Prache, Olivier
2008-04-01
OLED displays have been known to exhibit high levels of performance with regards to contrast, response time, uniformity, and viewing angle, but a lifetime improvement has been perceived to be essential for broadening the applications of OLED's in the military and in the commercial market. As a result of this need, the US Army and eMagin Corporation established a Cooperative Research and Development Agreement (CRADA) to improve the lifetime of OLED displays. In 2006, eMagin Corporation developed long-life OLED-XL devices for use in their AMOLED microdisplays for head-worn applications, and RDECOM CERDEC NVESD ran life tests on these displays, finding over 200% lifetime improvement for the XL devices over the standard displays. Early results were published at the 2007 SPIE Defense and Security Symposium. Further life testing of XL and standard devices at ambient conditions and at high temperatures will be presented this year along with a recap of previous data. This should result in a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems: where good fits are made, and where further development might be needed. This is a continuation of the paper "Life test results of OLED-XL long-life devices for use in active matrix organic light emitting diode (AMOLED) displays for head mounted applications" presented at SPIE DSS in 2007.
Synthetic vision systems: the effects of guidance symbology, display size, and field of view.
Alexander, Amy L; Wickens, Christopher D; Hardy, Thomas J
2005-01-01
Two experiments conducted in a high-fidelity flight simulator examined the effects of guidance symbology, display size, and geometric field of view (GFOV) within a synthetic vision system (SVS). In Experiment 1, 18 pilots flew highlighted and low-lighted tunnel-in-the-sky displays, as well as a less cluttered follow-me aircraft (FMA), through a series of curved approaches over rugged terrain. The results revealed that both tunnels supported better flight path tracking and lower workload levels than did the FMA because of the availability of more preview information. Increasing tunnel intensity had no benefit on tracking and, in fact, degraded traffic awareness because of clutter and attentional tunneling. In Experiment 2, 24 pilots flew a lowlighted tunnel configured according to different display sizes (small or large) and GFOVs (30 degrees or 60 degrees). Measures of flight path tracking and terrain awareness generally favored the 60 degrees GFOV; however, there were no effects of display size. Actual or potential applications of this research include understanding the impact of SVS properties on flight path tracking, traffic and terrain awareness, workload, and the allocation of attention.
Perceptual load corresponds with factors known to influence visual search
Roper, Zachary J. J.; Cosman, Joshua D.; Vecera, Shaun P.
2014-01-01
One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a non-circular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spill-over to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. These results suggest that perceptual load might be defined in part by well-characterized, continuous factors that influence visual search. PMID:23398258
Development and usage of a false color display technique for presenting Seasat-A scatterometer data
NASA Technical Reports Server (NTRS)
Jackson, C. B.
1980-01-01
A computer generated false color program which creates digital multicolor graphics to display geophysical surface parameters measured by the Seasat-A satellite scatterometer (SASS) is described. The data is incrementally scaled over the range of acceptable values and each increment and its data points are assigned a color. The advantage of the false color display is that it visually infers cool or weak data versus hot or intense data by using the rainbow of colors. For example, with wind speeds, levels of yellow and red could be used to imply high winds while green and blue could imply calmer air. The SASS data is sorted into geographic regions and the final false color images are projected onto various world maps with superimposed land/water boundaries.
Spacesuit Data Display and Management System
NASA Technical Reports Server (NTRS)
Hall, David G.; Sells, Aaron; Shah, Hemal
2009-01-01
A prototype embedded avionics system has been designed for the next generation of NASA extra-vehicular-activity (EVA) spacesuits. The system performs biomedical and other sensor monitoring, image capture, data display, and data transmission. An existing NASA Phase I and II award winning design for an embedded computing system (ZIN vMetrics - BioWATCH) has been modified. The unit has a reliable, compact form factor with flexible packaging options. These innovations are significant, because current state-of-the-art EVA spacesuits do not provide capability for data displays or embedded data acquisition and management. The Phase 1 effort achieved Technology Readiness Level 4 (high fidelity breadboard demonstration). The breadboard uses a commercial-grade field-programmable gate array (FPGA) with embedded processor core that can be upgraded to a space-rated device for future revisions.
Human-Centered Design of Human-Computer-Human Dialogs in Aerospace Systems
NASA Technical Reports Server (NTRS)
Mitchell, Christine M.
1998-01-01
A series of ongoing research programs at Georgia Tech established a need for a simulation support tool for aircraft computer-based aids. This led to the design and development of the Georgia Tech Electronic Flight Instrument Research Tool (GT-EFIRT). GT-EFIRT is a part-task flight simulator specifically designed to study aircraft display design and single pilot interaction. ne simulator, using commercially available graphics and Unix workstations, replicates to a high level of fidelity the Electronic Flight Instrument Systems (EFIS), Flight Management Computer (FMC) and Auto Flight Director System (AFDS) of the Boeing 757/767 aircraft. The simulator can be configured to present information using conventional looking B757n67 displays or next generation Primary Flight Displays (PFD) such as found on the Beech Starship and MD-11.
Thompson, S N
2004-08-04
Many insects display non-homeostatic regulation over blood sugar level. The concentration of trehalose varies dramatically depending on physiological and nutritional state. In the absence of dietary carbohydrate, blood trehalose in larvae of the lepidopteran insect Manduca sexta is maintained by gluconeogenesis and is dependent on dietary protein consumption. In the present study, the effect of dietary fat on the glucogenic response of insects to increased dietary protein was examined by NMR analysis of (2-13C)pyruvate metabolism. Last instar larvae were maintained on a carbohydrate-free chemically defined artificial diet having variable levels of casein with and without corn oil. Gluconeogenic flux, the ratio of the rate of gluconeogenesis to the rate of glycolysis, was estimated from the 13C distribution in trehalose arising by gluconeogenesis and the 13C enrichment of alanine due to pyruvate cycling. Insects grew well on carbohydrate-free diets and growth increased with increasing dietary protein level. At all dietary protein levels, larvae grew better on diets with fat. Without dietary fat, larvae were glucogenic but displayed low blood trehalose concentrations, <30 mM, regardless of protein consumption. When fat was included in the diet, however, gluconeogenic flux and blood trehalose level increased sharply in response to increased dietary protein level, with trehalose concentrations >50 mM at higher levels of protein consumption. When offered a choice of a high carbohydrate and a high protein diet, larvae maintained on diets with fat displayed a food preference related to blood sugar level. Those with low blood sugar fed on carbohydrate, while those with high blood sugar preferred protein. Trehalose synthesized from (2-13C)pyruvate exhibited asymmetry in the 13C distribution in individual glucose molecules, indicating a disequilibrium at the triose phosphate isomerase-catalyzed step of the gluconeogenic pathway. In trehalose from larvae on diets with fat, the asymmetric 13C distribution was higher than in trehalose from insects on diets lacking fat. This may partially result from isotopic disequilibrium when unenriched glycerol is metabolized to dihydroxyacetone phosphate following fat hydrolysis. The asymmetry in 13C distribution, however, also occurred in insects on diets without fat and decreased with increased gluconeogenic flux suggesting that true disequilibrium between the triose phosphates is the principal reason for the asymmetry.
Beyond Helper Phage: Using "Helper Cells" to Select Peptide Affinity Ligands.
Phipps, M Lisa; Lillo, Antoinetta M; Shou, Yulin; Schmidt, Emily N; Paavola, Chad D; Naranjo, Leslie; Bemdich, Sara; Swanson, Basil I; Bradbury, Andrew R M; Martinez, Jennifer S
2016-01-01
Peptides are important affinity ligands for microscopy, biosensing, and targeted delivery. However, because they can have low affinity for their targets, their selection from large naïve libraries can be challenging. When selecting peptidic ligands from display libraries, it is important to: 1) ensure efficient display; 2) maximize the ability to select high affinity ligands; and 3) minimize the effect of the display context on binding. The "helper cell" packaging system has been described as a tool to produce filamentous phage particles based on phagemid constructs with varying display levels, while remaining free of helper phage contamination. Here we report on the first use of this system for peptide display, including the systematic characterization and optimization of helper cells, their inefficient use in antibody display and their use in creating and selecting from a set of phage display peptide libraries. Our libraries were analyzed with unprecedented precision by standard or deep sequencing, and shown to be superior in quality than commercial gold standards. Using our helper cell libraries, we have obtained ligands recognizing Yersinia pestis surface antigen F1V and L-glutamine-binding periplasmic protein QBP. In the latter case, unlike any of the peptide library selections described so far, we used a combination of phage and yeast display to select intriguing peptide ligands. Based on the success of our selections we believe that peptide libraries obtained with helper cells are not only suitable, but preferable to traditional phage display libraries for selection of peptidic ligands.
AMO EXPRESS: A Command and Control Experiment for Crew Autonomy
NASA Technical Reports Server (NTRS)
Stetson, Howard K.; Frank, Jeremy; Cornelius, Randy; Haddock, Angie; Wang, Lui; Garner, Larry
2015-01-01
NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control demonstration of intelligent procedures to automatically initialize a rack onboard the International Space Station (ISS) with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures provide a step-by-step messaging paradigm and a high level status upon termination. This messaging and high level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high level execution status was transmitted to ground, for WebPD consumption.
Lephart, Edwin D.
2017-01-01
Phytochemicals are botanical compounds used in dermatology applications as cosmeceuticals to improve skin health. Resveratrol and equol are two of the best-known polyphenolic or phytoestrogens having similar chemical structures and some overlapping biological functions to 17β-estradiol. Human skin gene expression was reviewed for 28 different biomarkers when resveratrol, 4′ acetoxy resveratrol (4AR), R-equol, racemic equol or S-equol were tested. Sirtuin 1 activator (SIRT 1) was stimulated by resveratrol and 4AR only. Resveratrol, R-equol and racemic equol were effective on the aging biomarkers proliferating cell nuclear factor (PCNA), nerve growth factor (NGF), 5α-reductase and the calcium binding proteins S100 A8 and A9. Racemic equol and 4AR displayed among the highest levels for the collagens, elastin and tissue inhibitor of the matrix metalloproteinase 1 (TIMP 1). S-equol displayed the lowest level of effectiveness compared to the other compounds. The 4AR analog was more effective compared to resveratrol by 1.6-fold. R-equol and racemic equol were almost equal in potency displaying greater inhibition vs. resveratrol or its 4′ analog for the matrix metalloproteinases (MMPs), but among the inflammatory biomarkers, resveratrol, 4AR, R-equol and racemic equol displayed high inhibition. Thus, these cosmeceuticals display promise to improve dermal health; however, further study is warranted to understand how phytochemicals protect/enhance the skin. PMID:28587197
Health monitoring display system for a complex plant
Ridolfo, Charles F [Bloomfield, CT; Harmon, Daryl L [Enfield, CT; Colin, Dreyfuss [Enfield, CT
2006-08-08
A single page enterprise wide level display provides a comprehensive readily understood representation of the overall health status of a complex plant. Color coded failure domains allow rapid intuitive recognition of component failure status. A three-tier hierarchy of displays provide details on the health status of the components and systems displayed on the enterprise wide level display in a manner that supports a logical drill down to the health status of sub-components on Tier 1 to expected faults of the sub-components on Tier 2 to specific information relative to expected sub-component failures on Tier 3.
Ponnampalam, Eric N; Butler, Kym L; McDonagh, Matthew B; Jacobs, Joe L; Hopkins, David L
2012-02-01
The relationship between muscle vitamin E, forms of iron, polyunsaturated fatty acids (PUFA) and the redness of meat (retail display) at days 3 to 4 post slaughter from lambs offered 2 different diets was examined. Meat redness was positively related to vitamin E and heme iron and negatively related to total n-3, total n-6 and total PUFA content. However, after adjusting for the effects of vitamin E and heme iron content, there was no indication of any residual relationship between redness at days 3-4 of retail display and total n-3, total n-6 or total PUFA. This indicates that the relationship between PUFA and redness in meat is mediated through the effects of heme iron and vitamin E in the muscle. It appears that the level of highly oxidisable PUFAs in muscle tissues do not play a major role in maintenance of redness at days 3-4 of retail display, but the level of vitamin E and heme iron content are important. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
A succinct overview of virtual reality technology use in Alzheimer's disease.
García-Betances, Rebeca I; Arredondo Waldmeyer, María Teresa; Fico, Giuseppe; Cabrera-Umpiérrez, María Fernanda
2015-01-01
We provide a brief review and appraisal of recent and current virtual reality (VR) technology for Alzheimer's disease (AD) applications. We categorize them according to their intended purpose (e.g., diagnosis, patient cognitive training, caregivers' education, etc.), focus feature (e.g., spatial impairment, memory deficit, etc.), methodology employed (e.g., tasks, games, etc.), immersion level, and passive or active interaction. Critical assessment indicates that most of them do not yet take full advantage of virtual environments with high levels of immersion and interaction. Many still rely on conventional 2D graphic displays to create non-immersive or semi-immersive VR scenarios. Important improvements are needed to make VR a better and more versatile assessment and training tool for AD. The use of the latest display technologies available, such as emerging head-mounted displays and 3D smart TV technologies, together with realistic multi-sensorial interaction devices, and neuro-physiological feedback capacity, are some of the most beneficial improvements this mini-review suggests. Additionally, it would be desirable that such VR applications for AD be easily and affordably transferable to in-home and nursing home environments.
Mishellany-Dutour, Anne; Woda, Alain; Labouré, Hélène; Bourdiol, Pierre; Lachaze, Pauline; Guichard, Elisabeth; Feron, Gilles
2012-01-01
We hypothesized that interindividual differences in motor activities during chewing and/or swallowing were determining factors for the transfer of volatile aroma from the in-mouth air cavity (IMAC) toward the olfactory mucosa. In our first experiment, we looked for changes in IMAC volume after saliva deglutition in 12 healthy subjects. The mean IMAC volume was measured after empty deglutition using an acoustic pharyngometer device. Based on the time course of the IMAC volume after swallowing, we discerned two groups of subjects. The first group displayed a small, constant IMAC volume (2.26 mL ±0.62) that corresponded to a high tongue position. The second group displayed a progressive increase in IMAC (from 6.82 mL ±2.37 to 22.82 mL ±3.04) that corresponded to a progressive lowering of the tongue to its resting position. In our second experiment, we investigated the relationship between IMAC volume changes after deglutition and the level of aroma release at the nostril. For this purpose, the release of menthone was measured at the nostril level in 25 subjects who consumed similar amounts of a mint tablet. The subjects were separated into two groups corresponding to two levels of menthone release: high (H) and low (L). The mean volume of IMAC was measured during and after empty deglutition. Group H displayed a small, constant amplitude of IMAC volume change after deglutition, while Group L displayed a progressive increase in IMAC. It is likely that Group H continuously released the aroma through the veloglossal isthmus as the mint was consumed, while Group L trapped the aroma in the oral cavity and then released it into the nasal cavity upon swallowing. These results show that the in vivo aroma release profile in humans depends closely on the different motor patterns at work during empty deglutition. PMID:22815986
ADAMS executive and operating system
NASA Technical Reports Server (NTRS)
Pittman, W. D.
1981-01-01
The ADAMS Executive and Operating System, a multitasking environment under which a variety of data reduction, display and utility programs are executed, a system which provides a high level of isolation between programs allowing them to be developed and modified independently, is described. The Airborne Data Analysis/Monitor System (ADAMS) was developed to provide a real time data monitoring and analysis capability onboard Boeing commercial airplanes during flight testing. It inputs sensor data from an airplane performance data by applying transforms to the collected sensor data, and presents this data to test personnel via various display media. Current utilization and future development are addressed.
Projection displays and MEMS: timely convergence for a bright future
NASA Astrophysics Data System (ADS)
Hornbeck, Larry J.
1995-09-01
Projection displays and microelectromechanical systems (MEMS) have evolved independently, occasionally crossing paths as early as the 1950s. But the commercially viable use of MEMS for projection displays has been illusive until the recent invention of Texas Instruments Digital Light Processing TM (DLP) technology. DLP technology is based on the Digital Micromirror DeviceTM (DMD) microchip, a MEMS technology that is a semiconductor digital light switch that precisely controls a light source for projection display and hardcopy applications. DLP technology provides a unique business opportunity because of the timely convergence of market needs and technology advances. The world is rapidly moving to an all- digital communications and entertainment infrastructure. In the near future, most of the technologies necessary for this infrastrucutre will be available at the right performance and price levels. This will make commercially viable an all-digital chain (capture, compression, transmission, reception decompression, hearing, and viewing). Unfortunately, the digital images received today must be translated into analog signals for viewing on today's televisions. Digital video is the final link in the all-digital infrastructure and DLP technoogy provides that link. DLP technology is an enabler for digital, high-resolution, color projection displays that have high contrast, are bright, seamless, and have the accuracy of color and grayscale that can be achieved only by digital control. This paper contains an introduction to DMD and DLP technology, including the historical context from which to view their developemnt. The architecture, projection operation, and fabrication are presented. Finally, the paper includes an update about current DMD business opportunities in projection displays and hardcopy.
Information display: the weak link for NCW
NASA Astrophysics Data System (ADS)
Gilger, Mike
2006-05-01
The Global Information Grid (GIG) enables the dissemination of real-time data from any sensor/source as well as the distribution of that data immediately to recipients across the globe, resulting in better, faster, and more accurate decisions, reduced operational risk, and a more competitive war-fighting advantage. As a major component of Network Centric Warfare (NCW), the GIG seeks to provide the integrated information infrastructure necessary to connect the robust data streams from ConstellationNet, FORCENet, and LandWarNet to allow Joint Forces to move beyond Situational Awareness and into Situational Understanding. NCW will provide the Joint Forces a common situational understanding, a common operating picture, and any and all information necessary for rapid decision-making. However, with the exception of the 1994 introduction of the Military Standard 2525 "Common Warfighting Symbology," there has been no notable improvement in our ability to display information for accurate and rapid understanding. In fact, one of the notable problems associated with NCW is how to process the massive amount of newly integrated data being thrown at the warfighter: a significant human-machine interface challenge. The solution; a graphical language called GIFIC (Graphical Interface for Information Cognition) that can display thousands of data points simultaneously. Coupled with the new generation COP displays, GIFIC provides for the tremendous amounts of information-display required for effective NCW battlespace awareness requirements, offering instant insight into joint operations, tactical situations, and targeting necessities. GIFIC provides the next level of information-display necessary for a successful NCW, resulting in agile, high-performance, and highly competitive warfighters.
NASA Technical Reports Server (NTRS)
Marshall, Paul; Carts, Marty; Campbell, Art; Reed, Robert; Ladbury, Ray; Seidleck, Christina; Currie, Steve; Riggs, Pam; Fritz, Karl; Randall, Barb
2004-01-01
A viewgraph presentation that reviews recent SiGe bit error test data for different commercially available high speed SiGe BiCMOS chips that were subjected to various levels of heavy ion and proton radiation. Results for the tested chips at different operating speeds are displayed in line graphs.
Performance, physiological, and oculometer evaluation of VTOL landing displays
NASA Technical Reports Server (NTRS)
North, R. A.; Stackhouse, S. P.; Graffunder, K.
1979-01-01
A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Physiological, visual response, and conventional flight performance measures were recorded for landing approaches performed in the NASA Visual Motion Simulator (VMS). Three displays (two computer graphic and a conventional flight director), three crosswind amplitudes, and two motion base conditions (fixed vs. moving base) were tested in a factorial design. Multivariate discriminant functions were formed from flight performance and/or visual response variables. The flight performance variable discriminant showed maximum differentation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus represent higher workload levels.
In vitro Fab display: a cell-free system for IgG discovery
Stafford, Ryan L.; Matsumoto, Marissa L.; Yin, Gang; Cai, Qi; Fung, Juan Jose; Stephenson, Heather; Gill, Avinash; You, Monica; Lin, Shwu-Hwa; Wang, Willie D.; Masikat, Mary Rose; Li, Xiaofan; Penta, Kalyani; Steiner, Alex R.; Baliga, Ramesh; Murray, Christopher J.; Thanos, Christopher D.; Hallam, Trevor J.; Sato, Aaron K.
2014-01-01
Selection technologies such as ribosome display enable the rapid discovery of novel antibody fragments entirely in vitro. It has been assumed that the open nature of the cell-free reactions used in these technologies limits selections to single-chain protein fragments. We present a simple approach for the selection of multi-chain proteins, such as antibody Fab fragments, using ribosome display. Specifically, we show that a two-chain trastuzumab (Herceptin) Fab domain can be displayed in a format which tethers either the heavy or light chain to the ribosome while retaining functional antigen binding. Then, we constructed synthetic Fab HC and LC libraries and performed test selections against carcinoembryonic antigen (CEA) and vascular endothelial growth factor (VEGF). The Fab selection output was reformatted into full-length immunoglobulin Gs (IgGs) and directly expressed at high levels in an optimized cell-free system for immediate screening, purification and characterization. Several novel IgGs were identified using this cell-free platform that bind to purified CEA, CEA positive cells and VEGF. PMID:24586053
NASA Astrophysics Data System (ADS)
Chen, Shu-Hsia; Wu, Shin-Tson
1992-10-01
A broad range of interdisciplinary subjects related to display technologies is addressed, with emphasis on high-definition displays, CRTs, projection displays, materials for display application, flat-panel displays, display modeling, and polymer-dispersed liquid crystals. Particular attention is given to a CRT approach to high-definition television display, a superhigh-resolution electron gun for color display CRT, a review of active-matrix liquid-crystal displays, color design for LCD parameters in projection and direct-view applications, annealing effects on ZnS:TbF3 electroluminescent devices prepared by RF sputtering, polycrystalline silicon thin film transistors with low-temperature gate dielectrics, refractive index dispersions of liquid crystals, a new rapid-response polymer-dispersed liquid-crystal material, and improved liquid crystals for active-matrix displays using high-tilt-orientation layers. (No individual items are abstracted in this volume)
Moreno, Megan A; Kacvinsky, Lauren; Pumper, Megan; Wachowski, Leah; Whitehill, Jennifer M.
2013-01-01
Background Mifflin Street Block Party is a yearly Wisconsin event known for high levels of alcohol consumption and previous negative outcomes. This study investigated displayed Mifflin references on Facebook and their association with alcohol consumption at Mifflin. Methods Participants included first-year college students who were enrolled in a longitudinal study involving Facebook profile assessments and interviews. We identified a subset of participants who were interviewed within 28 days following Mifflin. Participants were categorized as “Mifflin Displayers” or “Non-Displayers” based on Facebook profile content. Interviews included the TimeLine FollowBack to assess alcohol use in the past 28 days. Analysis included logistic and linear regression. Results Among the 66 participants included in this study, 45 (68.2%) were female and 38 (50%) were Mifflin Displayers on Facebook. Among the Mifflin Displayer participants, 18 (27.2%) displayed prior to Mifflin, 11 displayed the day of Mifflin (16.7%) and 19 (28.8%) displayed after. Some participants displayed in more than one time frame. A total of 40 (60.6%) reported alcohol use on the day of the Mifflin Street Block party. The mean number of drinks reported on the day of Mifflin was 8.8 (SD=6.1), with a range of 1 to 35. Displayed references to Mifflin on Facebook were positively associated with reporting alcohol use at Mifflin (OR=20.9, 95% CI 5.6–78.8). Discussion Displaying Facebook references to Mifflin was associated with alcohol consumption on the day of the event. Future prevention efforts could consider creating Facebook advertisements with safety messages triggered by Mifflin displays. PMID:24511865
Transfer of Training from Predictor to Conventional Displays. Interim Report.
ERIC Educational Resources Information Center
Wulfeck, J. W.
Use of a predictor display has been shown to virtually transform the difficulty of a variety of complex, manual control pursuit tracking tasks to the level of those having relatively simple control requirements. With 15-minutes practice, naive operators are able to perform some complex tasks with a predictor display at accuracy levels previously…
Al-Rmalli, Shaban W; Jenkins, Richard O; Haris, Parvez I
2011-02-07
A relationship between betel quid chewing in Bangladeshi populations and the development of skin lesions and tremor has been previously reported, for people exposed to high levels of arsenic (As) through drinking contaminated groundwater. Exposure to manganese (Mn) is also known to induce neurotoxicity and levels of Mn in Bangladeshi groundwater are also high. The present study evaluates betel quid chewing as an overlooked source of Mn exposure in a Bangladeshi population. Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine (1) urinary Mn levels for 15 chewers and 22 non-chewers from the ethnic Bangladeshi community in the United Kingdom, and (2) Mn levels in betel quids, its individual components and other Bangladeshi foods. Betel quid chewers displayed a significantly higher (P = 0.009) mean Mn concentration in urine (1.93 μg L(-1)) compared to non-chewers (0.62 μg L(-1)). High levels of Mn were detected in Piper betel leaves with an overall average of 135 mg kg(-1) (range 26 -518 mg kg(-1)). The mean concentration of Mn in betel quid was 41 mg kg(-1) (SD 27) and the daily intake of Mn in the Bangladeshi population was estimated to be 20.3 mg/day. Chewing six betel quids could contribute up to 18% of the maximum recommended daily intake of Mn. We have demonstrated that Mn in betel quids is an overlooked source of exposure to Mn in humans. Chewers display a 3.1 fold increased urinary Mn concentration compared to non-chewers. The practice of betel quid chewing contributes a high proportion of the maximum recommended daily intake of Mn, which could make chewers in Bangladesh more vulnerable to Mn neurotoxicity.
2011-01-01
Background A relationship between betel quid chewing in Bangladeshi populations and the development of skin lesions and tremor has been previously reported, for people exposed to high levels of arsenic (As) through drinking contaminated groundwater. Exposure to manganese (Mn) is also known to induce neurotoxicity and levels of Mn in Bangladeshi groundwater are also high. The present study evaluates betel quid chewing as an overlooked source of Mn exposure in a Bangladeshi population. Methods Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine (1) urinary Mn levels for 15 chewers and 22 non-chewers from the ethnic Bangladeshi community in the United Kingdom, and (2) Mn levels in betel quids, its individual components and other Bangladeshi foods. Results Betel quid chewers displayed a significantly higher (P = 0.009) mean Mn concentration in urine (1.93 μg L-1) compared to non-chewers (0.62 μg L-1). High levels of Mn were detected in Piper betel leaves with an overall average of 135 mg kg-1 (range 26 -518 mg kg-1). The mean concentration of Mn in betel quid was 41 mg kg-1 (SD 27) and the daily intake of Mn in the Bangladeshi population was estimated to be 20.3 mg/day. Chewing six betel quids could contribute up to 18% of the maximum recommended daily intake of Mn. Conclusion We have demonstrated that Mn in betel quids is an overlooked source of exposure to Mn in humans. Chewers display a 3.1 fold increased urinary Mn concentration compared to non-chewers. The practice of betel quid chewing contributes a high proportion of the maximum recommended daily intake of Mn, which could make chewers in Bangladesh more vulnerable to Mn neurotoxicity. PMID:21299859
Budagovsky 9 rootstock: uncovering a novel resistance to fire blight
USDA-ARS?s Scientific Manuscript database
Budagovsky 9 (B.9) apple rootstock, displayed a high level of susceptibility (similar to M.9 rootstock) to fire blight bacteria (Erwinia amylovora) when leaves of non-grafted B.9 plants were inoculated. However, when older B.9 rootstock tissue was inoculated directly with E. amylovora, rootstock tis...
Relationship between Increase in Astrocytic GLT-1 Glutamate Transport and Late-LTP
ERIC Educational Resources Information Center
Pita-Almenar, Juan D.; Zou, Shengwei; Colbert, Costa M.; Eskin, Arnold
2012-01-01
Na[superscript +]-dependent high-affinity glutamate transporters have important roles in the maintenance of basal levels of glutamate and clearance of glutamate during synaptic transmission. Interestingly, several studies have shown that basal glutamate transport displays plasticity. Glutamate uptake increases in hippocampal slices during early…
Using Matlab in a Multivariable Calculus Course.
ERIC Educational Resources Information Center
Schlatter, Mark D.
The benefits of high-level mathematics packages such as Matlab include both a computer algebra system and the ability to provide students with concrete visual examples. This paper discusses how both capabilities of Matlab were used in a multivariate calculus class. Graphical user interfaces which display three-dimensional surfaces, contour plots,…
76 FR 51350 - Aerospace Executive Service Trade Mission (AESTM) to Seoul, Korea
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-18
... Korean governments and private aerospace and defense companies, the AESTM service at this major aerospace..., government officials, senior company managers, and high-level executives involved in the aerospace and... display company literature and conduct meetings with visitors to the air show. Company information and...
Bibliography of In-House and Contract Reports. Supplement 16
1989-10-01
Differences from ETL-71-CR-10 1971 Grav,t% and Gravity Gradients 54 TiLE REPORT NO. YEAR Determination of Level Sensitivity (Field ETL-RN-74-4 1974...Data Base Study, Phase II ETL-0360 1984 High Resolution Optical Power Spectrum Analyzer ETL-0127 1978 High Resolution Orthophoto Output Table (HIROOT...AD 856 731L 1969 High Resolution Orthophoto Output Table ETL-ETR-72-3 1972 High Speed Disc Memory and a Color Image AD 878 975L 1970 Display for a
Optimum display luminance depends on white luminance under various ambient illuminance conditions
NASA Astrophysics Data System (ADS)
Kim, Minkoo; Jeon, Dong-Hwan; Kim, Jeong-Sik; Yu, Byung-Chang; Park, YungKyung; Lee, Seung-Woo
2018-02-01
This paper reports display luminance levels for good visibility under nine ambient illuminance conditions (50, 100, 200, 500, 1000, 2000, 5000, 10,000, and 20,000 lx) for a given white luminance level, chosen from five candidates (100, 200, 500, 1000, and 2000 cd / m2), through a psychophysical experiment. This work reveals that the luminance levels for good visibility increase as the maximum white luminance of the display increases. The white luminance dependency of display luminance is caused by the fact that the human visual system adapts to the maximum white luminance and evaluates the brightness of the display based on it. Based on the experimental results, an appropriate luminance zone under various illuminance conditions is proposed. The appropriate luminance zone varies with the maximum white luminance of the displays. This may be understood to mean that there is no absolute luminance level under a given lighting condition. To solve this issue, a new method is proposed to determine optimum luminance levels by considering both visibility and power consumption. By the proposed method, it is reported that the optimum maximum luminance lies between 200 and 500 cd / m2 for indoor use (below 500 lx). These results were verified by young adults with normal vision.
Boosting immunity to small tumor-associated carbohydrates with bacteriophage qβ capsids.
Yin, Zhaojun; Comellas-Aragones, Marta; Chowdhury, Sudipa; Bentley, Philip; Kaczanowska, Katarzyna; Benmohamed, Lbachir; Gildersleeve, Jeffrey C; Finn, M G; Huang, Xuefei
2013-01-01
The development of an effective immunotherapy is an attractive strategy toward cancer treatment. Tumor associated carbohydrate antigens (TACAs) are overexpressed on a variety of cancer cell surfaces, which present tempting targets for anticancer vaccine development. However, such carbohydrates are often poorly immunogenic. To overcome this challenge, we show here that the display of a very weak TACA, the monomeric Tn antigen, on bacteriophage Qβ virus-like particles elicits powerful humoral responses to the carbohydrate. The effects of adjuvants, antigen display pattern, and vaccine dose on the strength and subclasses of antibody responses were established. The local density of antigen rather than the total amount of antigen administered was found to be crucial for induction of high Tn-specific IgG titers. The ability to display antigens in an organized and high density manner is a key advantage of virus-like particles such as Qβ as vaccine carriers. Glycan microarray analysis showed that the antibodies generated were highly selective toward Tn antigens. Furthermore, Qβ elicited much higher levels of IgG antibodies than other types of virus-like particles, and the IgG antibodies produced reacted strongly with the native Tn antigens on human leukemia cells. Thus, Qβ presents a highly attractive platform for the development of carbohydrate-based anticancer vaccines.
An Assessment of the Importance of Technologies to Military Capabilities.
1980-10-01
64 1 . 64 1 .64 24 14 9 . 91 TnTAL. .4" .46 .4, r7., .I- 34.92 .2.1 - THT14 NIif - WFArl’N - CANG/MT’. FArTOR, WT 00 00 O ~e. DI.TCI Cl IM61T Fl...NUCLEAR STRUCTURE 6 Figure 2-4a LEVEL-BY-LEVEL DISPLAY 9 Figure 2-4b LEVEL-BY-LEVEL DISPLAY 11 1 . tii TABLES Page tTable 3-1 LIST OF TECHNOLOGIES 15...00 .00 3) rLCTR OPTC *(56) .00 .00 .00 .00 .00 .00 .00 .00 TOTAL .00 .00 .00 .00 .00 .00 .00 .00 Figure 2-4a LEVEL-BY-LEVEL DISPLAY 9 I
Next generation smart window display using transparent organic display and light blocking screen.
Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk
2018-04-02
Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.
The Effects of Specialization and Sex on Anterior Y-Balance Performance in High School Athletes
Miller, Madeline M.; Trapp, Jessica L.; Post, Eric G.; Trigsted, Stephanie M.; McGuine, Timothy A.; Brooks, M. Alison; Bell, David R.
2017-01-01
Background: Sport specialization and movement asymmetry have been separately discussed as potential risk factors for lower extremity injury. Early specialization may lead to the development of movement asymmetries that can predispose an athlete to injury, but this has not been thoroughly examined. Hypothesis: Athletes rated as specialized would exhibit greater between-limb anterior reach asymmetry and decreased anterior reach distance on the Y-balance test (YBT) as compared with nonspecialized high school athletes, and these differences would not be dependent on sex. Study Design: Cross-sectional study. Level of Evidence: Level 3. Methods: Two hundred ninety-five athletes (117 male, 178 female; mean age, 15.6 ± 1.2 years) from 2 local high schools participating in basketball, soccer, volleyball, and tennis responded to a questionnaire regarding sport specialization status and performed trials of the YBT during preseason testing. Specialization was categorized according to 3 previously utilized specialization classification methods (single/multisport, 3-point scale, and 6-point scale), and interactions between specialization and sex with Y-balance performance were calculated using 2-way analyses of variance. Results: Single-sport male athletes displayed greater anterior reach asymmetry than other interaction groups. A consistent main effect was observed for sex, with men displaying greater anterior asymmetry and decreased anterior reach distance than women. However, the interaction effects of specialization and sex on anterior Y-balance performance varied based on the classification method used. Conclusion: Single-sport male athletes displayed greater anterior reach asymmetry on the YBT than multisport and female athletes. Specialization classification method is important because the 6- and 3-point scales may not accurately identify balance abnormalities. Male athletes performed worse than female athletes on both of the Y-balance tasks. Clinical Relevance: Clinicians should be aware that single-sport male athletes may display deficits in dynamic balance, potentially increasing their risk of injury. PMID:28447871
Kilic, Mahmut; Avci, Dilek; Uzuncakmak, Tugba
2016-01-01
The aim of this study is to examine the Internet addiction among adolescents in relation to their sociodemographic characteristics, communication skills, and perceived familial social support. This cross-sectional research is conducted in the high schools in some city centers, in Turkey, in 2013. In this study, cluster sampling was used. In each school, a class for each grade level was randomly selected, and all the students in the selected classes were included in the sample. One thousand seven hundred forty-two students aged between 14 and 20 years were included in the sample.The mean Internet Addiction Scale (IAS) score of the students was found to be 27.9 ± 21.2. According to the scores obtained from IAS, 81.8% of the students were found to display no symptoms (<50 points), 16.9% were found to display borderline symptoms (50-79 points), and 1.3% were found to be Internet addicts (≥80 points). According to the results of the binary logistic regression, male students and the students in single sex vocational schools were found to report higher levels of borderline Internet addiction. It was also observed that the IAS score increases when the father's educational level increases and when the students' school performance is worse. On the other hand, the IAS score decreases when the student grade level, perceived family social support, and communication skills scores increase.The risk factors for Internet addiction are being a male, low academic achievement, inadequate social support and communication skills, and father's high educational level.
Timing considerations of Helmet Mounted Display performance
NASA Technical Reports Server (NTRS)
Tharp, Gregory; Liu, Andrew; French, Lloyd; Lai, Steve; Stark, Lawrence
1992-01-01
The Helmet Mounted Display (HMD) system developed in our lab should be a useful teleoperator systems display if it increases operator performance of the desired task; it can, however, introduce degradation in performance due to display update rate constraints and communication delays. Display update rates are slowed by communication bandwidth and/or computational power limitations. We used simulated 3D tracking and pick-and-place tasks to characterize performance levels for a range of update rates. Initial experiments with 3D tracking indicate that performance levels plateau at an update rate between 10 and 20 Hz. We have found that using the HMD with delay decreases performance as delay increases.
A programmable display layer for virtual reality system architectures.
Smit, Ferdi Alexander; van Liere, Robert; Froehlich, Bernd
2010-01-01
Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We describe an architecture that provides a programmable display layer (PDL) in order to generate updated display frames. This replaces the default display behavior of repeating application frames until an update is available. We will show three benefits of the architecture typical to VR. First, smooth motion is provided by generating intermediate display frames by per-pixel depth-image warping using 3D motion fields. Smooth motion eliminates various perceptual artifacts due to judder. Second, we implement fine-grained latency reduction at the display frame level using a synchronized prediction of simulation objects and the viewpoint. This improves the average quality and consistency of latency reduction. Third, a crosstalk reduction algorithm for consecutive display frames is implemented, which improves the quality of stereoscopic images. To evaluate the architecture, we compare image quality and latency to that of a classic level-of-detail approach.
Color calibration of liquid crystal displays
NASA Astrophysics Data System (ADS)
Cazes, Albert N.; Braudaway, Gordon W.; Christensen, James; Cordes, Michael; DeCain, Don; Lien, Shui-Chih A.; Mintzer, Frederick C.; Wright, Steven L.
1999-04-01
For more than a decade the Image Applications department at IBMs Watson Research Center has been involved in cultural and commercial imaging projects that demand high-fidelity color reproduction of precious objects like paintings, illuminated manuscripts or jewelry. Our primary display media have been high-resolution cathode ray tubes (CRT), but for the last three years our customers have been replacing them with liquid crystal displays (LCD). The color calibration model we have been using for the CRT is the one described in the literature. It assumes that the chromas of the primaries are independent of intensity, that the colors produced from them are additive and that the intensity of black is almost zero. We measured several models of LCDs and observed that they poorly satisfied these assumptions at medium to low intensities. This becomes noticeable if the image has dark areas or if the display is viewed under a weak ambient light. In this paper, we use a modified version of the CRT model to calibrate the LCD. First we measure four sets of red, green, blue and gray patches. THen we determine the correction factor needed to make, at each level,the sum of the primaries equal to the corresponding gray. Finally, we use these factors to modify the data of red, green and blue.
NASA Technical Reports Server (NTRS)
Tennant, Allyn F.
1991-01-01
PLT is a high level plotting package. A Programmer can create a default plot suited for the data being displayed. At run times, users can then interact with the plot overriding any or all of these defaults. The user is also provided the capability to fit functions to the displayed data. This ability to display, interact with, and to fit the data make PLT a useful tool in the analysis of data. The Quick and Dandy Plotter (QDP) program will read ASCII text files that contain PLT commands and data. Thus, QDP provides and easy way to use the PLT software QPD files provide a convenient way to exchange data. The QPD/PLT software is written in standard FORTRAN 77 and has been ported to VAX VMS, SUN UNIX, IBM AIX, NeXT NextStep, and MS-DOS systems.
Roussel, Magali; Dreyer, Erwin; Montpied, Pierre; Le-Provost, Grégoire; Guehl, Jean-Marc; Brendel, Oliver
2009-01-01
(13)C discrimination in organic matter with respect to atmospheric CO(2) (Delta(13)C) is under tight genetic control in many plant species, including the pedunculate oak (Quercus robur L.) full-sib progeny used in this study. Delta(13)C is expected to reflect intrinsic water use efficiency, but this assumption requires confirmation due to potential interferences with mesophyll conductance to CO(2), or post-photosynthetic discrimination. In order to dissect the observed Delta(13)C variability in this progeny, six genotypes that have previously been found to display extreme phenotypic values of Delta(13)C [either very high ('high Delta') or low ('low Delta') phenotype] were selected, and transpiration efficiency (TE; accumulated biomass/transpired water), net CO(2) assimilation rate (A), stomatal conductance for water vapour (g(s)), and intrinsic water use efficiency (W(i)=A/g(s)) were compared with Delta(13)C in bulk leaf matter, wood, and cellulose in wood. As expected, 'high Delta' displayed higher values of Delta(13)C not only in bulk leaf matter, but also in wood and cellulose. This confirmed the stability of the genotypic differences in Delta(13)C recorded earlier. 'High Delta' also displayed lower TE, lower W(i), and higher g(s). A small difference was detected in photosynthetic capacity but none in mesophyll conductance to CO(2). 'High Delta' and 'low Delta' displayed very similar leaf anatomy, except for higher stomatal density in 'high Delta'. Finally, diurnal courses of leaf gas exchange revealed a higher g(s) in 'high Delta' in the morning than in the afternoon when the difference decreased. The gene ERECTA, involved in the control of water use efficiency, leaf differentiation, and stomatal density, displayed higher expression levels in 'low Delta'. In this progeny, the variability of Delta(13)C correlated closely with that of W(i) and TE. Genetic differences of Delta(13)C and W(i) can be ascribed to differences in stomatal conductance and stomatal density but not in photosynthetic capacity.
Geyer, Thomas; Baumgartner, Florian; Müller, Hermann J.; Pollmann, Stefan
2012-01-01
Using visual search, functional magnetic resonance imaging (fMRI) and patient studies have demonstrated that medial temporal lobe (MTL) structures differentiate repeated from novel displays—even when observers are unaware of display repetitions. This suggests a role for MTL in both explicit and, importantly, implicit learning of repeated sensory information (Greene et al., 2007). However, recent behavioral studies suggest, by examining visual search and recognition performance concurrently, that observers have explicit knowledge of at least some of the repeated displays (Geyer et al., 2010). The aim of the present fMRI study was thus to contribute new evidence regarding the contribution of MTL structures to explicit vs. implicit learning in visual search. It was found that MTL activation was increased for explicit and, respectively, decreased for implicit relative to baseline displays. These activation differences were most pronounced in left anterior parahippocampal cortex (aPHC), especially when observers were highly trained on the repeated displays. The data are taken to suggest that explicit and implicit memory processes are linked within MTL structures, but expressed via functionally separable mechanisms (repetition-enhancement vs. -suppression). They further show that repetition effects in visual search would have to be investigated at the display level. PMID:23060776
Verdonk, Koen; Saleh, Langeza; Lankhorst, Stephanie; Smilde, J E Ilse; van Ingen, Manon M; Garrelds, Ingrid M; Friesema, Edith C H; Russcher, Henk; van den Meiracker, Anton H; Visser, Willy; Danser, A H Jan
2015-06-01
Women with preeclampsia display low renin-angiotensin-aldosterone system activity and a high antiangiogenic state, the latter characterized by high levels of soluble Fms-like tyrosine kinase (sFlt)-1 and reduced placental growth factor levels. To investigate whether renin-angiotensin-aldosterone system suppression in preeclampsia is because of this disturbed angiogenic balance, we measured mean arterial pressure, creatinine, endothelin-1 (ET-1), and renin-angiotensin-aldosterone system components in pregnant women with a high (≥85; n=38) or low (<85; n=65) soluble Fms-like tyrosine kinase-1/placental growth factor ratio. Plasma ET-1 levels were increased in women with a high ratio, whereas their plasma renin activity and plasma concentrations of renin, angiotensinogen, and aldosterone were decreased. Plasma renin activity-aldosterone relationships were identical in both the groups. Multiple regression analysis revealed that plasma renin concentration correlated independently with mean arterial pressure and plasma ET-1. Plasma ET-1 correlated positively with soluble Fms-like tyrosine kinase-1 and negatively with plasma renin concentration, and urinary protein correlated with plasma ET-1 and mean arterial pressure. Despite the lower plasma levels of renin and angiotensinogen in the high-ratio group, their urinary levels of these components were elevated. Correction for albumin revealed that this was because of increased glomerular filtration. Subcutaneous arteries obtained from patients with preeclampsia displayed an enhanced, AT2 receptor-mediated response to angiotensin II. In conclusion, a high antiangiogenic state associates with ET-1 activation, which together with the increased mean arterial pressure may underlie the parallel reductions in renin and aldosterone in preeclampsia. Because ET-1 also was a major determinant of urinary protein, our data reveal a key role for ET-1 in the pathogenesis of preeclampsia. Finally, the enhanced angiotensin responsiveness in preeclampsia involves constrictor AT2 receptors. © 2015 American Heart Association, Inc.
System Collects And Displays Demultiplexed Data
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Fariss, Julie L.; Kulecz, Walter B.; Paloski, William H.
1992-01-01
Electronic system collects, manipulates, and displays in real time results of manipulation of streams of data transmitted from remote scientific instrumentation. Interface circuit shifts data-and-clock signal from differential logic levels of multiplexer to single-ended logic levels of computer. System accommodates nonstandard data-transmission protocol. Software useful in applications where Macintosh computers used in real-time display and recording of data.
High speed imager test station
Yates, George J.; Albright, Kevin L.; Turko, Bojan T.
1995-01-01
A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment.
High speed imager test station
Yates, G.J.; Albright, K.L.; Turko, B.T.
1995-11-14
A test station enables the performance of a solid state imager (herein called a focal plane array or FPA) to be determined at high image frame rates. A programmable waveform generator is adapted to generate clock pulses at determinable rates for clock light-induced charges from a FPA. The FPA is mounted on an imager header board for placing the imager in operable proximity to level shifters for receiving the clock pulses and outputting pulses effective to clock charge from the pixels forming the FPA. Each of the clock level shifters is driven by leading and trailing edge portions of the clock pulses to reduce power dissipation in the FPA. Analog circuits receive output charge pulses clocked from the FPA pixels. The analog circuits condition the charge pulses to cancel noise in the pulses and to determine and hold a peak value of the charge for digitizing. A high speed digitizer receives the peak signal value and outputs a digital representation of each one of the charge pulses. A video system then displays an image associated with the digital representation of the output charge pulses clocked from the FPA. In one embodiment, the FPA image is formatted to a standard video format for display on conventional video equipment. 12 figs.
Beyond helper phage: Using "helper cells" to select peptide affinity ligands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phipps, Mary Lisa; Lillo, Antoinetta M.; Shou, Yulin
Peptides are important affinity ligands for microscopy, biosensing, and targeted delivery. However, because they can have low affinity for their targets, their selection from large naïve libraries can be challenging. When selecting peptidic ligands from display libraries, it is important to: 1) ensure efficient display; 2) maximize the ability to select high affinity ligands; and 3) minimize the effect of the display context on binding. The “helper cell” packaging system has been described as a tool to produce filamentous phage particles based on phagemid constructs with varying display levels, while remaining free of helper phage contamination. Here we report onmore » the first use of this system for peptide display, including the systematic characterization and optimization of helper cells, their inefficient use in antibody display and their use in creating and selecting from a set of phage display peptide libraries. Our libraries were analyzed with unprecedented precision by standard or deep sequencing, and shown to be superior in quality than commercial gold standards. Using our helper cell libraries, we have obtained ligands recognizing Yersinia pestis surface antigen F1V and L-glutamine-binding periplasmic protein QBP. In the latter case, unlike any of the peptide library selections described so far, we used a combination of phage and yeast display to select intriguing peptide ligands. Here, based on the success of our selections we believe that peptide libraries obtained with helper cells are not only suitable, but preferable to traditional phage display libraries for selection of peptidic ligands.« less
Buck, Ross; Powers, Stacie R; Hull, Kyle S
2017-10-01
Most measures of nonverbal receiving ability use posed expressions as stimuli. As empathy measures, such stimuli lack ecological validity, as the participant is not actually experiencing emotion. An alternative approach uses natural and dynamic displays of spontaneous expressions. The Communication of Affect Receiving Ability Test (CARAT) uses as stimuli spontaneous facial expressions and gestures filmed by an unobtrusive camera of solitary participants responding to emotional images. This article reports the development and initial validation of the CARAT-Spontaneous, Posed, Regulated (CARAT-SPR), which measures both abilities to detect emotion from spontaneous displays (emotion communication accuracy) and to differentiate spontaneous, posed, and regulated displays (expression categorization ability). Although spontaneous displays are natural responses to emotional images, posed displays involve asking the sender to display "as if" responding to a particular sort of image when no image is in fact present (simulation), while Regulated displays involve asking the sender to display "as if" responding to a particular sort of image when an image of opposite valence is in fact present (masking). Expression categorization ability involves judging deception-simulation and masking-and conceptually involves a kind of perspective-taking or cognitive empathy. Emotion communication using spontaneous clips achieved a high level of accuracy and was strongly correlated with ratings of sender expressivity. Expression categorization ability was not significantly correlated with expressivity ratings and was modestly negatively correlated with emotion communication accuracy. In a brief version of the CARAT-SPR, women showed evidence of greater emotion signal detection, whereas men reported greater confidence in expression categorization. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Beyond helper phage: Using "helper cells" to select peptide affinity ligands
Phipps, Mary Lisa; Lillo, Antoinetta M.; Shou, Yulin; ...
2016-09-14
Peptides are important affinity ligands for microscopy, biosensing, and targeted delivery. However, because they can have low affinity for their targets, their selection from large naïve libraries can be challenging. When selecting peptidic ligands from display libraries, it is important to: 1) ensure efficient display; 2) maximize the ability to select high affinity ligands; and 3) minimize the effect of the display context on binding. The “helper cell” packaging system has been described as a tool to produce filamentous phage particles based on phagemid constructs with varying display levels, while remaining free of helper phage contamination. Here we report onmore » the first use of this system for peptide display, including the systematic characterization and optimization of helper cells, their inefficient use in antibody display and their use in creating and selecting from a set of phage display peptide libraries. Our libraries were analyzed with unprecedented precision by standard or deep sequencing, and shown to be superior in quality than commercial gold standards. Using our helper cell libraries, we have obtained ligands recognizing Yersinia pestis surface antigen F1V and L-glutamine-binding periplasmic protein QBP. In the latter case, unlike any of the peptide library selections described so far, we used a combination of phage and yeast display to select intriguing peptide ligands. Here, based on the success of our selections we believe that peptide libraries obtained with helper cells are not only suitable, but preferable to traditional phage display libraries for selection of peptidic ligands.« less
2008-05-01
communicate with other weapon models In a mission-level simulation; (3) introduces the four configuration levels of the M&S framework; and (4) presents a cost ...and Disadvantages ....................................................................... 26 6 COST -EFFECTIVE M&S LABORATORY PLAN...25 23 Weapon Model Sample Time and Average TET Displayed on the Target PC ..... 26 24 Design and Cost of an
Performance of the Volumetric Diffusive Respirator at Altitude
2014-08-18
information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM...increased by 30-40%. Tidal volume remained within 15% of sea level values. Respiratory rate fell, while inspiratory time increased and high frequency...altitude, positive end expiratory pressure and peak inspiratory pressure were increased by 30-40%. Tidal volume remained within 15% of sea level
High volume nanoscale roll-based imprinting using jet and flash imprint lithography
NASA Astrophysics Data System (ADS)
Ahn, Se Hyun; Miller, Michael; Yang, Shuqiang; Ganapathisubramanian, Maha; Menezes, Marlon; Singh, Vik; Wan, Fen; Choi, Jin; Xu, Frank; LaBrake, Dwayne; Resnick, Douglas J.; Hofemann, Paul; Sreenivasan, S. V.
2014-03-01
Extremely large-area roll-to-roll manufacturing on flexible substrates is ubiquitous for applications such as paper and plastic processing. The challenge is to extend this approach to the realm of nanopatterning and realize similar benefits. Display applications, including liquid crystal (LCD), organic light emitting diode (OLED) and flexible displays are particularly interesting because of the ability to impact multiple levels in the basic display. Of particular interest are the polarizer, DBEF, thin film transistor and color filter; roll-based imprinting has the opportunity to create high performance components within the display while improving the cost of ownership of the panel. Realization of these devices requires both a scalable imprinting technology and tool. In this paper, we introduce a high volume roll-based nanopatterning system, the LithoFlex 350TM. The LithoFlex 350 uses an inkjet based imprinting process similar to the technology demonstrator tool, the LithoFlex 100, introduced in 2012. The width of the web is 350mm and patterning width is 300mm. The system can be configured either for Plate-to-Roll (P2R) imprinting (in which a rigid template is used to pattern the flexible web material) or for Roll-to-Plate imprinting (R2P) (in which a web based template is used to pattern either wafers or panels). Also described in this paper are improvements to wire grid polarizer devices. By optimizing the deposition, patterning and etch processes, we have been able to create working WGPs with transmittance and extinction ratios as high as 44% and 50,000, respectively.
Real-time, high frequency QRS electrocardiograph
NASA Technical Reports Server (NTRS)
Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)
2006-01-01
Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as RAZs. RAZs are displayed as go, no-go signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.
Brachypodium distachyon. A New Model System for Functional Genomics in Grasses1
Draper, John; Mur, Luis A.J.; Jenkins, Glyn; Ghosh-Biswas, Gadab C.; Bablak, Pauline; Hasterok, Robert; Routledge, Andrew P.M.
2001-01-01
A new model for grass functional genomics is described based on Brachypodium distachyon, which in the evolution of the Pooideae diverged just prior to the clade of “core pooid” genera that contain the majority of important temperate cereals and forage grasses. Diploid ecotypes of B. distachyon (2n = 10) have five easily distinguishable chromosomes that display high levels of chiasma formation at meiosis. The B. distachyon nuclear genome was indistinguishable in size from that of Arabidopsis, making it the simplest genome described in grasses to date. B. distachyon is a self-fertile, inbreeding annual with a life cycle of less than 4 months. These features, coupled with its small size (approximately 20 cm at maturity), lack of seed-head shatter, and undemanding growth requirements should make it amenable to high-throughput genetics and mutant screens. Immature embryos exhibited a high capacity for plant regeneration via somatic embryogenesis. Regenerated plants display very low levels of albinism and have normal fertility. A simple transformation system has been developed based on microprojectile bombardment of embryogenic callus and hygromycin selection. Selected B. distachyon ecotypes were resistant to all tested cereal-adapted Blumeria graminis species and cereal brown rusts (Puccinia reconditia). In contrast, different ecotypes displayed resistance or disease symptoms following challenge with the rice blast pathogen (Magnaporthe grisea) and wheat/barley yellow stripe rusts (Puccinia striformis). Despite its small stature, B. distachyon has large seeds that should prove useful for studies on grain filling. Such biological characteristics represent important traits for study in temperate cereals. PMID:11743099
Peripheral visual response time and visual display layout
NASA Technical Reports Server (NTRS)
Haines, R. F.
1974-01-01
Experiments were performed on a group of 42 subjects in a study of their peripheral visual response time to visual signals under positive acceleration, during prolonged bedrest, at passive 70 deg headup body lift, under exposures to high air temperatures and high luminance levels, and under normal stress-free laboratory conditions. Diagrams are plotted for mean response times to white, red, yellow, green, and blue stimuli under different conditions.
Towards highly stable polymer electronics (Conference Presentation)
NASA Astrophysics Data System (ADS)
Nikolka, Mark; Nasrallah, Iyad; Broch, Katharina; Sadhanala, Aditya; Hurhangee, Michael; McCulloch, Iain; Sirringhaus, Henning
2016-11-01
Due to their ease of processing, organic semiconductors are promising candidates for applications in high performance flexible displays and fast organic electronic circuitry. Recently, a lot of advances have been made on organic semiconductors exhibiting surprisingly high performance and carrier mobilities exceeding those of amorphous silicon. However, there remain significant concerns about their operational and environmental stability, particularly in the context of applications that require a very high level of threshold voltage stability, such as active-matrix addressing of organic light-emitting diode (OLED) displays. Here, we report a novel technique for dramatically improving the operational stress stability, performance and uniformity of high mobility polymer field-effect transistors by the addition of specific small molecule additives to the polymer semiconductor film. We demonstrate for the first time polymer FETs that exhibit stable threshold voltages with threshold voltage shifts of less than 1V when subjected to a constant current operational stress for 1 day under conditions that are representative for applications in OLED active matrix displays. The approach constitutes in our view a technological breakthrough; it also makes the device characteristics independent of the atmosphere in which it is operated, causes a significant reduction in contact resistance and significantly improves device uniformity. We will discuss in detail the microscopic mechanism by which the molecular additives lead to this significant improvement in device performance and stability.
Aznar-Moreno, Jose A; Venegas Calerón, Mónica; Martínez-Force, Enrique; Garcés, Rafael; Mullen, Robert; Gidda, Satinder K; Salas, Joaquín J
2014-03-01
Long chain fatty acid synthetases (LACSs) activate the fatty acid chains produced by plastidial de novo biosynthesis to generate acyl-CoA derivatives, important intermediates in lipid metabolism. Oilseeds, like sunflower, accumulate high levels of triacylglycerols (TAGs) in their seeds to nourish the embryo during germination. This requires that sunflower seed endosperm supports very active glycerolipid synthesis during development. Sunflower seed plastids produce large amounts of fatty acids, which must be activated through the action of LACSs, in order to be incorporated into TAGs. We cloned two different LACS genes from developing sunflower endosperm, HaLACS1 and HaLACS2, which displayed sequence homology with Arabidopsis LACS9 and LACS8 genes, respectively. These genes were expressed at high levels in developing seeds and exhibited distinct subcellular distributions. We generated constructs in which these proteins were fused to green fluorescent protein and performed transient expression experiments in tobacco cells. The HaLACS1 protein associated with the external envelope of tobacco chloroplasts, whereas HaLACS2 was strongly bound to the endoplasmic reticulum. Finally, both proteins were overexpressed in Escherichia coli and recovered as active enzymes in the bacterial membranes. Both enzymes displayed similar substrate specificities, with a very high preference for oleic acid and weaker activity toward stearic acid. On the basis of our findings, we discuss the role of these enzymes in sunflower oil synthesis. © 2013 Scandinavian Plant Physiology Society.
Segregation and persistence of form in the lateral occipital complex.
Ferber, Susanne; Humphrey, G Keith; Vilis, Tutis
2005-01-01
While the lateral occipital complex (LOC) has been shown to be implicated in object recognition, it is unclear whether this brain area is responsive to low-level stimulus-driven features or high-level representational processes. We used scrambled shape-from-motion displays to disambiguate the presence of contours from figure-ground segregation and to measure the strength of the binding process for shapes without contours. We found persisting brain activation in the LOC for scrambled displays after the motion stopped indicating that this brain area subserves and maintains figure-ground segregation processes, a low-level function in the object processing hierarchy. In our second experiment, we found that the figure-ground segregation process has some form of spatial constancy indicating top-down influences. The persisting activation after the motion stops suggests an intermediate role in object recognition processes for this brain area and might provide further evidence for the idea that the lateral occipital complex subserves mnemonic functions mediating between iconic and short-term memory.
NASA Astrophysics Data System (ADS)
Haqiqiansyah, G.; Sugiharto, E.
2018-04-01
This research was conducted to identify and scrutinize women empowerment of fish product processing group in the District of Sanga-Sanga on 2017. The method used was survey method, which is direct observation and interview to respondent. Data were collected in the form of primary and secondary data. Collected data then processed, tabulated, and displayed in the table and graph. The measurement of women empowerment degree was measured by Likert Scale on 3 level, that are score 1 = low, score 2 = less, and score 3 = high. The result of research demonstrated that the rate of empowerment women group of fish product processor was high (score 42,75). Partially, awareness level or willingness to change of processing enterprise group which indicate empowerment indicator categorized as high (91,67%). The level of capability to increase the chance of acquiring access was high (66,67%), the level of capability to overcome an obstacle tend to categorized as less (50%) and the level of capability to collaborate was high (66,67%). It means that the level of coastal women empowerment could be reliable to do a reformation.
Perceptual load corresponds with factors known to influence visual search.
Roper, Zachary J J; Cosman, Joshua D; Vecera, Shaun P
2013-10-01
One account of the early versus late selection debate in attention proposes that perceptual load determines the locus of selection. Attention selects stimuli at a late processing level under low-load conditions but selects stimuli at an early level under high-load conditions. Despite the successes of perceptual load theory, a noncircular definition of perceptual load remains elusive. We investigated the factors that influence perceptual load by using manipulations that have been studied extensively in visual search, namely target-distractor similarity and distractor-distractor similarity. Consistent with previous work, search was most efficient when targets and distractors were dissimilar and the displays contained homogeneous distractors; search became less efficient when target-distractor similarity increased irrespective of display heterogeneity. Importantly, we used these same stimuli in a typical perceptual load task that measured attentional spillover to a task-irrelevant flanker. We found a strong correspondence between search efficiency and perceptual load; stimuli that generated efficient searches produced flanker interference effects, suggesting that such displays involved low perceptual load. Flanker interference effects were reduced in displays that produced less efficient searches. Furthermore, our results demonstrate that search difficulty, as measured by search intercept, has little bearing on perceptual load. We conclude that rather than be arbitrarily defined, perceptual load might be defined by well-characterized, continuous factors that influence visual search. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Jensen, Leonardo; Neri, Elida; Bassaneze, Vinicius; De Almeida Oliveira, Nathalia C; Dariolli, Rafael; Turaça, Lauro T; Levy, Débora; Veronez, Douglas; Ferraz, Mariana S A; Alencar, Adriano M; Bydlowski, Sérgio P; Cestari, Idágene A; Krieger, José Eduardo
2018-07-01
Neonatal cardiomyocytes are instrumental for disease modeling, but the effects of different cell extraction methods on basic cell biological processes remain poorly understood. We assessed the influence of two popular methods to extract rat neonatal cardiomyocytes, Pre-plating (PP), and Percoll (PC) on cell structure, metabolism, and function. Cardiomyocytes obtained from PP showed higher gene expression for troponins, titin, and potassium and sodium channels compared to PC. Also, PP cells displayed higher levels of troponin I protein. Cells obtained from PC displayed higher lactate dehydrogenase activity and lactate production than PP cells, indicating higher anaerobic metabolism after 8 days of culture. In contrast, reactive oxygen species levels were higher in PP cells as indicated by ethidium and hydroxyethidium production. Consistent with these data, protein nitration was higher in PP cells, as well as nitrite accumulation in cell medium. Moreover, PP cells showed higher global intracellular calcium under basal and 1 mM isoprenaline conditions. In a calcium-transient assessment under electrical stimulation (0.5 Hz), PP cells displayed higher calcium amplitude than cardiomyocytes obtained from PC and using a traction force microscope technique we observed that PP cardiomyocytes showed the highest relaxation. Collectively, we demonstrated that extraction methods influence parameters related to cell structure, metabolism, and function. Overall, PP derived cells are more active and mature than PC cells, displaying higher contractile function and generating more reactive oxygen species. On the other hand, PC derived cells display higher anaerobic metabolism, despite comparable high yields from both protocols. © 2017 Wiley Periodicals, Inc.
A web-based dashboard for the high-level monitoring of ALMA
NASA Astrophysics Data System (ADS)
Pietriga, Emmanuel; Filippi, Giorgio; Véliz, Luis; del Campo, Fernando; Ibsen, Jorge
2014-07-01
The ALMA radio-telescope's operations depend on the availability of high-level, easy-to-understand status information about all of its components. The ALMA Dashboard aims at providing an all-in-one-place near-real-time overview of the observatory's key elements and figures to both line and senior management. The Dashboard covers a wide range of elements beyond antennas, such as pads, correlator and central local oscillator. Data can be displayed in multiple ways, including: a table view, a compact view fitting on a single screen, a timeline showing detailed information over time, a logbook, a geographical map.
Han, Lei; Liang, Bo; Song, Jianxia
2018-02-01
As an important cofactor, NADH is essential for most redox reactions and biofuel cells. However, supply of exogenous NADH is challenged, due to the low production efficiency and high cost of NADH regeneration system, as well as low stability of NADH. Here, we constructed a novel cell surface multi-enzyme co-display system with ratio- and space-controllable manner as exogenous NADH regeneration system for the sustainable NADH production from low-cost biomass. Dockerin-fused glucoamylase (GA) and glucose dehydrogenase (GDH) were expressed and assembled on the engineered bacterial surfaces, which displayed protein scaffolds with various combinations of different cohesins. When the ratio of GA and GDH was 3:1, the NADH production rate of the whole-cell biocatalyst reached the highest level using starch as substrate, which was three times higher than that of mixture of free enzymes, indicating that the highly ordered spatial organization of enzymes would promote reactions, due to the ratio of enzymes and proximity effect. To confirm performance of the established NADH regeneration system, the highly efficient synthesis of L-lactic acid (L-LA) was conducted by the system and the yield of L-LA (16 g/L) was twice higher than that of the mixture of free enzymes. The multi-enzyme co-display system showed good stability in the cyclic utilization. In conclusion, the novel sustainable NADH system would provide a cost-effective strategy to regenerate cofactor from low-cost biomass.
NASA Technical Reports Server (NTRS)
Arthur, Jarvis (Trey) J., III; Shelton, Kevin J.; Prinzel, Lawrence J.; Nicholas, Stephanie N.; Williams, Steven P.; Ellis, Kyle E.; Jones, Denise R.; Bailey, Randall E.; Harrison, Stephanie J.; Barnes, James R.
2017-01-01
Research, development, test, and evaluation of fight deck interface technologies is being conducted by the National Aeronautics and Space Administration (NASA) to proactively identify, develop, and mature tools, methods, and technologies for improving overall aircraft safety of new and legacy vehicles operating in the Next Generation Air Transportation System (NextGen). One specific area of research was the use of small Head-Worn Displays (HWDs) to serve as a possible equivalent to a Head-Up Display (HUD). A simulation experiment and a fight test were conducted to evaluate if the HWD can provide an equivalent level of performance to a HUD. For the simulation experiment, airline crews conducted simulated approach and landing, taxi, and departure operations during low visibility operations. In a follow-on fight test, highly experienced test pilots evaluated the same HWD during approach and surface operations. The results for both the simulation and fight tests showed that there were no statistical differences in the crews' performance in terms of approach, touchdown and takeoff; but, there are still technical hurdles to be overcome for complete display equivalence including, most notably, the end-to-end latency of the HWD system.
Global Repetition Influences Contextual Cueing
Zang, Xuelian; Zinchenko, Artyom; Jia, Lina; Li, Hong
2018-01-01
Our visual system has a striking ability to improve visual search based on the learning of repeated ambient regularities, an effect named contextual cueing. Whereas most of the previous studies investigated contextual cueing effect with the same number of repeated and non-repeated search displays per block, the current study focused on whether a global repetition frequency formed by different presentation ratios between the repeated and non-repeated configurations influence contextual cueing effect. Specifically, the number of repeated and non-repeated displays presented in each block was manipulated: 12:12, 20:4, 4:20, and 4:4 in Experiments 1–4, respectively. The results revealed a significant contextual cueing effect when the global repetition frequency is high (≥1:1 ratio) in Experiments 1, 2, and 4, given that processing of repeated displays was expedited relative to non-repeated displays. Nevertheless, the contextual cueing effect reduced to a non-significant level when the repetition frequency reduced to 4:20 in Experiment 3. These results suggested that the presentation frequency of repeated relative to the non-repeated displays could influence the strength of contextual cueing. In other words, global repetition statistics could be a crucial factor to mediate contextual cueing effect. PMID:29636716
Global Repetition Influences Contextual Cueing.
Zang, Xuelian; Zinchenko, Artyom; Jia, Lina; Assumpção, Leonardo; Li, Hong
2018-01-01
Our visual system has a striking ability to improve visual search based on the learning of repeated ambient regularities, an effect named contextual cueing. Whereas most of the previous studies investigated contextual cueing effect with the same number of repeated and non-repeated search displays per block, the current study focused on whether a global repetition frequency formed by different presentation ratios between the repeated and non-repeated configurations influence contextual cueing effect. Specifically, the number of repeated and non-repeated displays presented in each block was manipulated: 12:12, 20:4, 4:20, and 4:4 in Experiments 1-4, respectively. The results revealed a significant contextual cueing effect when the global repetition frequency is high (≥1:1 ratio) in Experiments 1, 2, and 4, given that processing of repeated displays was expedited relative to non-repeated displays. Nevertheless, the contextual cueing effect reduced to a non-significant level when the repetition frequency reduced to 4:20 in Experiment 3. These results suggested that the presentation frequency of repeated relative to the non-repeated displays could influence the strength of contextual cueing. In other words, global repetition statistics could be a crucial factor to mediate contextual cueing effect.
Monti, Laura L; Bustamante, Claudia A; Osorio, Sonia; Gabilondo, Julieta; Borsani, Julia; Lauxmann, Martin A; Maulión, Evangelina; Valentini, Gabriel; Budde, Claudio O; Fernie, Alisdair R; Lara, María V; Drincovich, María F
2016-01-01
Peach (Prunus persica) fruits from different varieties display differential organoleptic and nutritional properties, characteristics related to their chemical composition. Here, chemical biodiversity of peach fruits from fifteen varieties, at harvest and after post-harvest ripening, was explored by gas chromatography-mass spectrometry. Metabolic profiling revealed that metabolites involved in organoleptic properties (sugars, organic and amino acids), stress tolerance (raffinose, galactinol, maltitol), and with nutritional properties (amino, caffeoylquinic and dehydroascorbic acids) displayed variety-dependent levels. Peach varieties clustered into four groups: two groups of early-harvest varieties with higher amino acid levels; two groups of mid- and late-harvest varieties with higher maltose levels. Further separation was mostly dependent on organic acids/raffinose levels. Variety-dependent and independent metabolic changes associated with ripening were detected; which contribute to chemical diversity or can be used as ripening markers, respectively. The great variety-dependent diversity in the content of metabolites that define fruit quality reinforces metabolomics usage as a tool to assist fruit quality improvement in peach. Copyright © 2015 Elsevier Ltd. All rights reserved.
The Effects of Transgressors' Affective Reaction on Children's Moral Judgments.
ERIC Educational Resources Information Center
Rybash, John M.; Roodin, Paul A.
1982-01-01
Describes a study which showed that a transgressor's affective reactions significantly influenced children's moral judgments. Children in grades 1-3 told stories in which a transgressor acted out of good or bad intent, produced low or high levels of damage, and displayed various emotions because of the outcomes he produced. (RM)
ERIC Educational Resources Information Center
Broderick, Patricia C.; Korteland, Constance
2002-01-01
Three studies investigated interrelationships among coping styles, gender roles, and level of depression for early adolescents. Girls displayed more depression than boys. More highly depressed girls demonstrated coping patterns similar to those of depressed adolescent and adult women. People who identified with feminine gender roles showed…
ERIC Educational Resources Information Center
Curran, Thomas; Standage, Martyn
2017-01-01
Motivation research is central to understanding why certain students exhibit high levels of behavioral, cognitive, and emotional engagement with learning, and why others lack interest, display boredom, and withdraw effort (i.e., are disaffected). In this review, tenets within self-determination theory (SDT) are used to provide a…
Organizational Justice and Commitment in Interscholastic Sports
ERIC Educational Resources Information Center
Whisenant, Warren
2005-01-01
The purpose of this study was to determine the effect of three organizational justice dimensions on the commitment of high school student athletes (N = 480) to continue playing a referent sport. The athletes were asked to complete an instrument designed to assess their perceived levels of justice displayed by their coaches in three justice…
Microcomputers in the Classroom: Don't Exclude the Developmentally Disabled.
ERIC Educational Resources Information Center
Schall, William E.; And Others
1985-01-01
This study tested the hypothesis that 15- to 21-year-old educable mentally retarded students could successfully interact with microcomputers and show interest in using them as a learning tool. High interest levels and attention spans and positive microcomputer attitudes displayed by subjects suggest there may be unrealized potential in…
ERIC Educational Resources Information Center
Perez-Edgar, Koraly; Reeb-Sutherland, Bethany C.; McDermott, Jennifer Martin; White, Lauren K.; Henderson, Heather A.; Degnan, Kathryn A.; Hane, Amie A.; Pine, Daniel S.; Fox, Nathan A.
2011-01-01
Behaviorally inhibited children display a temperamental profile characterized by social withdrawal and anxious behaviors. Previous research, focused largely on adolescents, suggests that attention biases to threat may sustain high levels of behavioral inhibition (BI) over time, helping link early temperament to social outcomes. However, no prior…
Li, Xiangrui; Lu, Zhong-Lin
2012-02-29
Display systems based on conventional computer graphics cards are capable of generating images with 8-bit gray level resolution. However, most experiments in vision research require displays with more than 12 bits of luminance resolution. Several solutions are available. Bit++ (1) and DataPixx (2) use the Digital Visual Interface (DVI) output from graphics cards and high resolution (14 or 16-bit) digital-to-analog converters to drive analog display devices. The VideoSwitcher (3) described here combines analog video signals from the red and blue channels of graphics cards with different weights using a passive resister network (4) and an active circuit to deliver identical video signals to the three channels of color monitors. The method provides an inexpensive way to enable high-resolution monochromatic displays using conventional graphics cards and analog monitors. It can also provide trigger signals that can be used to mark stimulus onsets, making it easy to synchronize visual displays with physiological recordings or response time measurements. Although computer keyboards and mice are frequently used in measuring response times (RT), the accuracy of these measurements is quite low. The RTbox is a specialized hardware and software solution for accurate RT measurements. Connected to the host computer through a USB connection, the driver of the RTbox is compatible with all conventional operating systems. It uses a microprocessor and high-resolution clock to record the identities and timing of button events, which are buffered until the host computer retrieves them. The recorded button events are not affected by potential timing uncertainties or biases associated with data transmission and processing in the host computer. The asynchronous storage greatly simplifies the design of user programs. Several methods are available to synchronize the clocks of the RTbox and the host computer. The RTbox can also receive external triggers and be used to measure RT with respect to external events. Both VideoSwitcher and RTbox are available for users to purchase. The relevant information and many demonstration programs can be found at http://lobes.usc.edu/.
Reeb-Sutherland, Bethany C.; McDermott, Jennifer Martin; White, Lauren K.; Henderson, Heather A.; Degnan, Kathryn A.; Hane, Amie A.; Pine, Daniel S.; Fox, Nathan A.
2013-01-01
Behaviorally inhibited children display a temperamental profile characterized by social withdrawal and anxious behaviors. Previous research, focused largely on adolescents, suggests that attention biases to threat may sustain high levels of behavioral inhibition (BI) over time, helping link early temperament to social outcomes. However, no prior studies examine the association between attention bias and BI before adolescence. The current study examined the interrelations among BI, attention biases to threat, and social withdrawal already manifest in early childhood. Children (N=187, 83 Male, Mage=61.96 months) were characterized for BI in toddlerhood (24 & 36 months). At 5 years, they completed an attention bias task and concurrent social withdrawal was measured. As expected, BI in toddlerhood predicted high levels of social withdrawal in early childhood. However, this relation was moderated by attention bias. The BI-withdrawal association was only evident for children who displayed an attention bias toward threat. The data provide further support for models associating attention with socioemotional development and the later emergence of clinical anxiety. PMID:21318555
Warner, R D; Kearney, G; Hopkins, D L; Jacob, R H
2017-07-01
The longissmus lumborum (LL) and semimembranosus (SM) muscles from 391 lamb carcasses, derived from various breed types, were used to investigate the effect of animal/muscle factors, packaging type [over-wrap (OW) or high oxygen modified atmosphere packaging (MAP O2 )] and duration of display on redness of meat during simulated retail display. Using statistical models the time required (in days) for redness to reach a threshold value of 3.5 (below this is unacceptable) was predicted. High levels of iron in the SM, but not LL, reduced the time for redness to reach 3.5 by 2-2.6days in MAP O2 and 0.5-0.8days in OW. The greater the proportion of Merino breed type, the shorter was the time for redness to reach the value of 3.5, an effect consistent across muscles and packaging types. In summary, breed type, packaging format, muscle and muscle iron levels had a significant impact on colour stability of sheep meat in oxygen-available packaging systems. Copyright © 2017. Published by Elsevier Ltd.
Poeschl, Sandra; Doering, Nicola
2013-01-01
Virtual training applications with high levels of immersion or fidelity (for example for social phobia treatment) produce high levels of presence and therefore belong to the most successful Virtual Reality developments. Whereas display and interaction fidelity (as sub-dimensions of immersion) and their influence on presence are well researched, realism of the displayed simulation depends on the specific application and is therefore difficult to measure. We propose to measure simulation realism by using a self-report questionnaire. The German VR Simulation Realism Scale for VR training applications was developed based on a translation of scene realism items from the Witmer-Singer-Presence Questionnaire. Items for realism of virtual humans (for example for social phobia training applications) were supplemented. A sample of N = 151 students rated simulation realism of a Fear of Public Speaking application. Four factors were derived by item- and principle component analysis (Varimax rotation), representing Scene Realism, Audience Behavior, Audience Appearance and Sound Realism. The scale developed can be used as a starting point for future research and measurement of simulation realism for applications including virtual humans.
Pérez-Edgar, Koraly; Reeb-Sutherland, Bethany C; McDermott, Jennifer Martin; White, Lauren K; Henderson, Heather A; Degnan, Kathryn A; Hane, Amie A; Pine, Daniel S; Fox, Nathan A
2011-08-01
Behaviorally inhibited children display a temperamental profile characterized by social withdrawal and anxious behaviors. Previous research, focused largely on adolescents, suggests that attention biases to threat may sustain high levels of behavioral inhibition (BI) over time, helping link early temperament to social outcomes. However, no prior studies examine the association between attention bias and BI before adolescence. The current study examined the interrelations among BI, attention biases to threat, and social withdrawal already manifest in early childhood. Children (N=187, 83 Male, M (age)=61.96 months) were characterized for BI in toddlerhood (24 & 36 months). At 5 years, they completed an attention bias task and concurrent social withdrawal was measured. As expected, BI in toddlerhood predicted high levels of social withdrawal in early childhood. However, this relation was moderated by attention bias. The BI-withdrawal association was only evident for children who displayed an attention bias toward threat. The data provide further support for models associating attention with socioemotional development and the later emergence of clinical anxiety.
Hamling, A E; Jenschke, B E; Calkins, C R
2008-04-01
The objective of this study was to determine the retail shelf stability of beef chuck and round muscles enhanced with ammonium hydroxide, salt, and carbon monoxide. A split plot design was used for each of 3 muscles [triceps brachii (TB), biceps femoris (BF), and rectus femoris (RF)] with 2 treatments (0 and 20% pump), 3 dark storage periods (1, 2, and 3 wk), and 3 replications in the whole plot and retail display period as the split plot. There were a total of 12 subprimals per treatment per dark storage period (n = 72 each). Individual steaks were cut to a thickness of 2.54 cm and packaged in a modified-atmosphere package (MAP). The TB was packaged in a high-oxygen MAP (80% oxygen, 20% carbon dioxide). The BF and RF were packaged in a low-oxygen MAP (100% carbon dioxide). At the completion of each dark storage period, steaks were subjected to 7 d of simulated retail display. Steaks were used for objective and subjective color measurements, total plate counts, and determination of retail purge and oxidation. For all muscles, total plate counts were always numerically greater in injected steaks. Triceps brachii steaks held in dark storage for 3 wk and displayed at retail for 4 or more days all exceeded 10(7) log of cfu/cm(2) for aerobic plate count. Biceps femoris and RF steaks packaged in a low-oxygen MAP had much lower bacterial counts, with levels below 4.2 log of cfu/cm(2), even after 7 d of retail display. Oxidation values for the TB were extremely high (ranging from 12.3 to 26.6), whereas the BF and RF had values that were much lower (< or =1.0 mg of malonaldehyde/kg of muscle), likely due to the oxidation occurring in a high-oxygen MAP for the TB. Enhanced TB steaks proved to have greater color stability (less discoloration) than nonenhanced TB steaks. In addition, the BF and RF (low-oxygen MAP) steaks had better color stability (more stable redness values) than TB (high-oxygen MAP) steaks, although TB steaks initially exhibited a brighter red color. Retail display life was enhanced by packaging in 100% carbon dioxide, and enhanced steaks exhibited greater color stability in retail display than control steaks.
Recent advances in flexible low power cholesteric LCDs
NASA Astrophysics Data System (ADS)
Khan, Asad; Shiyanovskaya, Irina; Montbach, Erica; Schneider, Tod; Nicholson, Forrest; Miller, Nick; Marhefka, Duane; Ernst, Todd; Doane, J. W.
2006-05-01
Bistable reflective cholesteric displays are a liquid crystal display technology developed to fill a market need for very low power displays. Their unique look, high reflectivity, bistability, and simple structure make them an ideal flat panel display choice for handheld or other portable devices where small lightweight batteries with long lifetimes are important. Applications ranging from low resolution large signs to ultra high resolution electronic books can utilize cholesteric displays to not only benefit from the numerous features, but also create enabling features that other flat panel display technologies cannot. Flexible displays are the focus of attention of numerous research groups and corporations worldwide. Cholesteric displays have been demonstrated to be highly amenable to flexible substrates. This paper will review recent advances in flexible cholesteric displays including both phase separation and emulsification approaches to encapsulation. Both approaches provide unique benefits to various aspects of manufacturability, processes, flexibility, and conformability.
Characterisation of particulate exposure during fireworks displays
NASA Astrophysics Data System (ADS)
Joly, Alexandre; Smargiassi, Audrey; Kosatsky, Tom; Fournier, Michel; Dabek-Zlotorzynska, Ewa; Celo, Valbona; Mathieu, David; Servranckx, René; D'amours, Réal; Malo, Alain; Brook, Jeffrey
2010-11-01
Little is known about the level and content of exposure to fine particles (PM 2.5) among persons who attend fireworks displays and those who live nearby. An evaluation of the levels of PM 2.5 and their elemental content was carried out during the nine launches of the 2007 Montréal International Fireworks Competition. For each event, a prediction of the location of the firework plume was obtained from the Canadian Meteorological Centre (CMC) of the Meteorological Service of Canada. PM 2.5 was measured continuously with a photometer (Sidepak™, TSI) within the predicted plume location ("predicted sites"), and integrated samples were collected using portable personal samplers. An additional sampler was located on a nearby roof ("fixed site"). The elemental composition of the collected PM 2.5 samples from the "predicted sites" was determined using both a non-destructive energy dispersive ED-XRF method and an ICP-MS method with a near-total microwave-assisted acid digestion. The elemental composition of the "fixed site" samples was determined by the ICP-MS with the near-total digestion method. The highest PM 2.5 levels reached nearly 10 000 μg m -3, roughly 1000 times background levels. Elements such as K, Cl, Al, Mg and Ti were markedly higher in plume-exposed filters. This study shows that 1) persons in the plume and in close proximity to the launch site may be exposed to extremely high levels of PM 2.5 for the duration of the display and, 2) that the plume contains specific elements for which little is known of their acute cardio-respiratory toxicity.
NASA Astrophysics Data System (ADS)
Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.
1997-07-01
Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.
High-performance large-area AMLCD avionic display module
NASA Astrophysics Data System (ADS)
Syroid, Daniel D.; Hansen, Glenn A.
1995-06-01
There is a need for a reliable source of high performance large area sunlight readable active matrix liquid crystal displays (AMLCDs) for avionic and military land vehicle applications. Image Quest has developed an avionic display module (ADM) to demonstrate the capability to produce high performance avionic displays to satisfy this need. The ADM is a large area (6.24 X 8.32 inch) display with VGA compatible interface, 640 X 480 color pixels and 64 gray shades per primary color. The display features excellent color discrimination in full sunlight due to a saturated color gamut, very low specular reflectance (< 1%) and high output white luminance (200 fL). The ADM is designed from the glass up to fully meet the avionic and military application and environment. Control over all the display performance parameters including contrast, transmission, chroma, resolution, active size and packaging configuration is ensured because Image Quest produces all of the critical elements of the display. These elements include the a-Si TFT AMLCD glass, RGB color filter matrix, bonding of folded back driver TABs, anti-reflective cover glass, LC heater and integration of high luminance hot cathode backlight with thermal controls. The display features rugged compact packaging, 2000:1 luminance dimming range and wide operating temperature range (-40 to +71 $DRGC). In the immediate future Image Quest plans to expand the development efforts to other similar custom high resolution and high performance avionic display module configurations including 4 X 4 inch delta triad, 6.7 X 6.7 inch delta triad and 16.5 inch diagonal with 1280 X 1024 pixels. Image Quest can deliver up to 10,000 displays per year on a timely basis at a reasonable cost.
Goldberg, Lori Sideman; Grandey, Alicia A
2007-07-01
"Service with a smile" is satisfying for the customer, but such display rules may be costly to the employee and the organization. Most previous research on such costs has used self-reported and cross-sectional designs. The authors use an experimental approach to test tenets of resource depletion theories; specifically, whether the self-regulation of emotions required by display rules depletes energy and attentional resources during a service encounter. Using a call center simulation with three "customer" interactions, the authors found that participants given positive display rules (e.g., be enthusiastic and hide frustration) reported more postsimulation exhaustion and made more errors on the order form compared to those with display autonomy. Customer hostility during one of the calls also increased exhaustion overall and the number of errors during that specific call, though proposed interactions with display rules were not supported. Surface-level emotion regulation, but not deep-level, was the mechanism for the energy depletion effect of display rules, while display rules had a direct effect on performance decrements. Theoretical and practical implications for display rules as part of job requirements are discussed. Copyright 2007 APA
Identification of plexin A4 as a novel clusterin receptor links two Alzheimer’s disease risk genes
Kang, Silvia S.; Kurti, Aishe; Wojtas, Aleksandra; Baker, Kelsey E.; Liu, Chia-Chen; Kanekiyo, Takahisa; Deming, Yuetiva; Cruchaga, Carlos; Estus, Steven; Bu, Guojun; Fryer, John D.
2016-01-01
Although abundant genetic and biochemical evidence strongly links Clusterin (CLU) to Alzheimer disease (AD) pathogenesis, the receptor for CLU within the adult brain is currently unknown. Using unbiased approaches, we identified Plexin A4 (PLXNA4) as a novel, high-affinity receptor for CLU in the adult brain. PLXNA4 protein expression was high in brain with much lower levels in peripheral organs. CLU protein levels were significantly elevated in the cerebrospinal fluid (CSF) of Plxna4-/- mice and, in humans, CSF levels of CLU were also associated with PLXNA4 genotype. Human AD brains had significantly increased the levels of CLU protein but decreased levels of PLXNA4 by ∼50%. To determine whether PLXNA4 levels influenced cognition, we analyzed the behaviour of Plxna4+/+, Plxna4+/-, and Plxna4-/- mice. In comparison to WT controls, both Plxna4+/- and Plxna4-/- mice were hyperactive in the open field assay while Plxna4-/- mice displayed a hyper-exploratory (low-anxiety phenotype) in the elevated plus maze. Importantly, both Plxna4+/- and Plxna4-/- mice displayed prominent deficits in learning and memory in the contextual fear-conditioning paradigm. Thus, even a 50% reduction in the level of PLXNA4 is sufficient to cause memory impairments, raising the possibility that memory problems seen in AD patients could be due to reductions in the level of PLXNA4. Both CLU and PLXNA4 have been genetically associated with AD risk and our data thus provide a direct relationship between two AD risk genes. Our data suggest that increasing the levels of PLXNA4 or targeting CLU-PLXNA4 interactions may have therapeutic value in AD. PMID:27378688
Identification of plexin A4 as a novel clusterin receptor links two Alzheimer's disease risk genes.
Kang, Silvia S; Kurti, Aishe; Wojtas, Aleksandra; Baker, Kelsey E; Liu, Chia-Chen; Kanekiyo, Takahisa; Deming, Yuetiva; Cruchaga, Carlos; Estus, Steven; Bu, Guojun; Fryer, John D
2016-08-15
Although abundant genetic and biochemical evidence strongly links Clusterin (CLU) to Alzheimer disease (AD) pathogenesis, the receptor for CLU within the adult brain is currently unknown. Using unbiased approaches, we identified Plexin A4 (PLXNA4) as a novel, high-affinity receptor for CLU in the adult brain. PLXNA4 protein expression was high in brain with much lower levels in peripheral organs. CLU protein levels were significantly elevated in the cerebrospinal fluid (CSF) of Plxna4 -/- mice and, in humans, CSF levels of CLU were also associated with PLXNA4 genotype. Human AD brains had significantly increased the levels of CLU protein but decreased levels of PLXNA4 by ∼50%. To determine whether PLXNA4 levels influenced cognition, we analyzed the behaviour of Plxna4 +/+ , Plxna4 +/- , and Plxna4 -/- mice. In comparison to WT controls, both Plxna4 +/- and Plxna4 -/- mice were hyperactive in the open field assay while Plxna4 -/- mice displayed a hyper-exploratory (low-anxiety phenotype) in the elevated plus maze. Importantly, both Plxna4 +/- and Plxna4 -/- mice displayed prominent deficits in learning and memory in the contextual fear-conditioning paradigm. Thus, even a 50% reduction in the level of PLXNA4 is sufficient to cause memory impairments, raising the possibility that memory problems seen in AD patients could be due to reductions in the level of PLXNA4. Both CLU and PLXNA4 have been genetically associated with AD risk and our data thus provide a direct relationship between two AD risk genes. Our data suggest that increasing the levels of PLXNA4 or targeting CLU-PLXNA4 interactions may have therapeutic value in AD. © The Author 2016. Published by Oxford University Press.
Long-term follow-up of echolalia and question answering.
Foxx, R M; Faw, G D
1990-01-01
A long-term follow-up of echolalia and correct question answering was conducted for 6 subjects from three previously published studies. The follow-up periods ranged from 26 to 57 months. In a training site follow-up, subjects were exposed to baseline/posttraining conditions in which the original trainer and/or a novel person(s) presented trained and untrained questions. Four subjects displayed echolalia below baseline levels, and another did so in some assessments. Overall, echolalia was lower than in baseline in 80.6% of the follow-ups. Five subjects displayed correct responding above baseline levels. No clear differences were noted in correct responding or echolalia between the trainer and novel-person presentations or between trained and untrained questions. In a follow-up in a natural environment conducted by a novel person, lower than baseline levels of echolalia were displayed by 3 subjects; 2 subjects displayed lower than baseline levels in some assessments. Two subjects consistently displayed correct responding above baseline, and 3 did so occasionally. Issues related to the study of maintenance are discussed.
Long-term follow-up of echolalia and question answering.
Foxx, R M; Faw, G D
1990-01-01
A long-term follow-up of echolalia and correct question answering was conducted for 6 subjects from three previously published studies. The follow-up periods ranged from 26 to 57 months. In a training site follow-up, subjects were exposed to baseline/posttraining conditions in which the original trainer and/or a novel person(s) presented trained and untrained questions. Four subjects displayed echolalia below baseline levels, and another did so in some assessments. Overall, echolalia was lower than in baseline in 80.6% of the follow-ups. Five subjects displayed correct responding above baseline levels. No clear differences were noted in correct responding or echolalia between the trainer and novel-person presentations or between trained and untrained questions. In a follow-up in a natural environment conducted by a novel person, lower than baseline levels of echolalia were displayed by 3 subjects; 2 subjects displayed lower than baseline levels in some assessments. Two subjects consistently displayed correct responding above baseline, and 3 did so occasionally. Issues related to the study of maintenance are discussed. PMID:2249974
Simulation and flight test evaluation of head-up-display guidance for harrier approach transitions
NASA Technical Reports Server (NTRS)
Dorr, D. W.; Moralez, E., III; Merrick, V. K.
1994-01-01
Position and speed guidance displays for STOVL aircraft curved, decelerating approaches to hover and vertical landing have been evaluated for their effectiveness in reducing pilot workload and improving performance. The NASA V/STOL Systems Research Aircraft, a modified YAV-8B Harrier prototype, was used to evaluate the displays in flight, whereas the NASA Ames Vertical Motion Simulator was used to extend the flight test results to instrument meteorological conditions (IMC) and to examine performance in various conditions of wind and turbulence. The simulation data showed close correlation with the flight test data, and both demonstrated the feasibility of the displays. With the exception of the hover task in zero visibility, which was level-3, averaged Copper-Harper handling qualities ratings given during simulation were level-2 for both the approach task and the hover task in all conditions. During flight tests in calm and clear conditions, the displays also gave rise to level-2 handling qualities ratings. Pilot opinion showed that the guidance displays would be useful in visual flight, especially at night, as well as in IMC.
Silva, Mariana; Fung, Ronald Kam Fai; Donnelly, Conor Brian; Videira, Paula Alexandra; Sackstein, Robert
2017-01-01
Both host defense and immunopathology are shaped by the ordered recruitment of circulating leukocytes to affected sites, a process initiated by binding of blood-borne cells to E-selectin displayed at target endothelial beds. Accordingly, knowledge of the expression and function of leukocyte E-selectin ligands is key to understanding the tempo and specificity of immunoreactivity. Here, we performed E-selectin adherence assays under hemodynamic flow conditions coupled with flow cytometry and western blot analysis to elucidate the function and structural biology of glycoprotein E-selectin ligands expressed on human peripheral blood mononuclear cells (PBMCs). Circulating monocytes uniformly express high levels of the canonical E-selectin binding determinant sLeX and display markedly greater adhesive interactions with E-selectin than do circulating lymphocytes, which exhibit variable E-selectin binding among CD4+ and CD8+ T-cells but no binding by B-cells. Monocytes prominently present sLeX decorations on an array of protein scaffolds including PSGL-1, CD43, and CD44 (rendering the E-selectin ligands CLA, CD43E, and HCELL, respectively), and B-cells altogether lack E-selectin ligands. Quantitative PCR gene expression studies of glycosyltransferases that regulate display of sLeX reveal high transcript levels among circulating monocytes and low levels among circulating B-cells, and, commensurately, cell surface α(1,3)-fucosylation reveals that acceptor sialyllactosaminyl glycans convertible into sLeX are abundantly expressed on human monocytes yet are relatively deficient on B-cells. Collectively, these findings unveil distinct cell-specific patterns of E-selectin ligand expression among human PBMCs, indicating that circulating monocytes are specialized to engage E-selectin and providing key insights into the molecular effectors mediating recruitment of these cells at inflammatory sites. PMID:28330896
Spatio-Temporal Dynamics of Cholera during the First Year of the Epidemic in Haiti
Gaudart, Jean; Rebaudet, Stanislas; Barrais, Robert; Boncy, Jacques; Faucher, Benoit; Piarroux, Martine; Magloire, Roc; Thimothe, Gabriel; Piarroux, Renaud
2013-01-01
Background In October 2010, cholera importation in Haiti triggered an epidemic that rapidly proved to be the world's largest epidemic of the seventh cholera pandemic. To establish effective control and elimination policies, strategies rely on the analysis of cholera dynamics. In this report, we describe the spatio-temporal dynamics of cholera and the associated environmental factors. Methodology/Principal findings Cholera-associated morbidity and mortality data were prospectively collected at the commune level according to the World Health Organization standard definition. Attack and mortality rates were estimated and mapped to assess epidemic clusters and trends. The relationships between environmental factors were assessed at the commune level using multivariate analysis. The global attack and mortality rates were 488.9 cases/10,000 inhabitants and 6.24 deaths/10,000 inhabitants, respectively. Attack rates displayed a significantly high level of spatial heterogeneity (varying from 64.7 to 3070.9 per 10,000 inhabitants), thereby suggesting disparate outbreak processes. The epidemic course exhibited two principal outbreaks. The first outbreak (October 16, 2010–January 30, 2011) displayed a centrifugal spread of a damping wave that suddenly emerged from Mirebalais. The second outbreak began at the end of May 2011, concomitant with the onset of the rainy season, and displayed a highly fragmented epidemic pattern. Environmental factors (river and rice fields: p<0.003) played a role in disease dynamics exclusively during the early phases of the epidemic. Conclusion Our findings demonstrate that the epidemic is still evolving, with a changing transmission pattern as time passes. Such an evolution could have hardly been anticipated, especially in a country struck by cholera for the first time. These results argue for the need for control measures involving intense efforts in rapid and exhaustive case tracking. PMID:23593516
Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection
NASA Technical Reports Server (NTRS)
Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)
2009-01-01
Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.
Yen, Yi-Chun; Mauch, Christoph P; Dahlhoff, Maik; Micale, Vincenzo; Bunck, Mirjam; Sartori, Simone B; Singewald, Nicolas; Landgraf, Rainer; Wotjak, Carsten T
2012-07-01
Patients diagnosed for anxiety disorders often display faster acquisition and slower extinction of learned fear. To gain further insights into the mechanisms underlying these phenomenona, we studied conditioned fear in mice originating form a bi-directional selective breeding approach, which is based on elevated plus-maze behavior and results in CD1-derived high (HAB), normal (NAB), and low (LAB) anxiety-related behavior mice. HAB mice displayed pronounced cued-conditioned fear compared to NAB/CD1 and LAB mice that coincided with increased phosphorylation of the protein kinase B (AKT) in the basolateral amygdala 45 min after conditioning. No similar changes were observed after non-associative immediate shock presentations. Fear extinction of recent but not older fear memories was preserved. However, HAB mice were more prone to relapse of conditioned fear with the passage of time. HAB mice also displayed higher levels of contextual fear compared to NAB and LAB mice and exaggerated avoidance following step-down avoidance training. Interestingly, HAB mice showed lower and LAB mice higher levels of acoustic startle responses compared to NAB controls. The increase in arousal observed in LAB mice coincided with the general absence of conditioned freezing. Taken together, our results suggest that the genetic predisposition to high anxiety-related behavior may increase the risk of forming traumatic memories, phobic-like fear and avoidance behavior following aversive encounters, with a clear bias towards passive coping styles. In contrast, genetic predisposition to low anxiety-related and high risk-taking behavior seems to be associated with an increase in active coping styles. Our data imply changes in AKT phosphorylation as a therapeutic target for the prevention of exaggerated fear memories. Copyright © 2012 Elsevier Inc. All rights reserved.
Young people's exposure to point-of-sale tobacco products and promotions.
Stead, M; Eadie, D; MacKintosh, A M; Best, C; Miller, M; Haseen, F; Pearce, J R; Tisch, C; Macdonald, L; MacGregor, A; Amos, A; van der Sluijs, W; Frank, J W; Haw, S
2016-07-01
Point of sale (POS) displays are one of the most important forms of tobacco marketing still permitted in many countries. Reliable methods for measuring exposure to such displays are needed in order to assess their potential impact, particularly on smoking attitudes and uptake among young people. In this study we use a novel method for evaluating POS exposure based on young people's use of retail outlets and recall of tobacco displays and observational data on the characteristics of displays. Observational audit of retail outlets (n = 96) and school-based pupil survey (n = 1482) in four Scottish communities reflecting different levels of social deprivation and urbanisation, conducted in 2013 before legislation to remove POS displays was implemented in supermarkets. Measures were taken of: visibility and placement of tobacco displays; internal and external advertising; display unit size, branding and design; visibility of pack warnings; proximity of tobacco products to products of potential interest to children and young people; pupils' self-reported frequency of visiting retail outlets; and pupils' recall of tobacco displays. Variation in POS exposure across social and demographic groups was assessed. Displays were highly visible within outlets and, in over half the stores, from the public footway outside. Tobacco products were displayed in close proximity to products of interest to children (e.g. confectionery, in 70% of stores). Eighty percent of pupils recalled seeing tobacco displays, with those from deprived areas more likely to recall displays in small shops. When confectioners, tobacconists and newsagents (CTNs) and grocery/convenience stores (two of the outlet types most often visited by young people) were examined separately, average tobacco display unit sizes were significantly larger in those outlets in more deprived areas. POS displays remain a key vector in most countries for advertising tobacco products, and it is important to develop robust measures of exposure. The data reported in this paper provide a baseline measure for evaluating the efficacy of legislation prohibiting such displays. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Undergraduate nursing students' level of assertiveness in Greece: a questionnaire survey.
Deltsidou, Anna
2009-09-01
A number of studies of nursing and midwifery have found stress and bullying to be frequent problems. Those suffering from bullying and stress need to have high levels of assertiveness to resist and to cope successfully. Hence, it was considered vital to assess the assertiveness level of nursing students throughout their training curriculum. The study population was composed of nursing students in different semesters at one school in Central Greece (n=298) who agreed to complete a questionnaire on assertiveness level assessment, which had been translated into Greek and adapted to this population. All students present in class completed the questionnaire, representing 80% of the total population of active students. Mean assertiveness scores between semesters were compared by ANOVA and comparisons between the responses of the first semester students and responses of advanced semester students were done by Pearson's chi square. The main finding of this study was that the assertiveness levels displayed by students increase slightly in advanced semesters by comparison to those displayed by first-semester students. Assertive behavior should be encouraged through learning methods. Nurses should preferably obtain this training throughout their studies. Instructors have an essential role in the improvement and achievement of assertiveness training curriculums for undergraduate nursing students.
Display formats and commercial vehicle operator (CVO) workload
DOT National Transportation Integrated Search
1997-09-01
The objective of this study was to determine the effects of display modality, level of driver interaction, and amount of information on the driving performance and system operation performance of commercial drivers. Introducing any level of interacti...
When less is best: female brown-headed cowbirds prefer less intense male displays.
O'Loghlen, Adrian L; Rothstein, Stephen I
2012-01-01
Sexual selection theory predicts that females should prefer males with the most intense courtship displays. However, wing-spread song displays that male brown-headed cowbirds (Molothrus ater) direct at females are generally less intense than versions of this display that are directed at other males. Because male-directed displays are used in aggressive signaling, we hypothesized that females should prefer lower intensity performances of this display. To test this hypothesis, we played audiovisual recordings showing the same males performing both high intensity male-directed and low intensity female-directed displays to females (N = 8) and recorded the females' copulation solicitation display (CSD) responses. All eight females responded strongly to both categories of playbacks but were more sexually stimulated by the low intensity female-directed displays. Because each pair of high and low intensity playback videos had the exact same audio track, the divergent responses of females must have been based on differences in the visual content of the displays shown in the videos. Preferences female cowbirds show in acoustic CSD studies are correlated with mate choice in field and captivity studies and this is also likely to be true for preferences elucidated by playback of audiovisual displays. Female preferences for low intensity female-directed displays may explain why male cowbirds rarely use high intensity displays when signaling to females. Repetitive high intensity displays may demonstrate a male's current condition and explain why these displays are used in male-male interactions which can escalate into physical fights in which males in poorer condition could be injured or killed. This is the first study in songbirds to use audiovisual playbacks to assess how female sexual behavior varies in response to variation in a male visual display.
Human factors studies of control configurations for advanced transport aircraft
NASA Technical Reports Server (NTRS)
Snyder, Harry L.; Monty, Robert W.; Old, Joe
1985-01-01
This research investigated the threshold levels of display luminance contrast which were required to interpret static, achromatic, integrated displays of primary flight information. A four-factor within-subjects design was used to investigate the influences of type of flight variable information, the level of ambient illumination, the type of control input, and the size of the display symbology on the setting of these interpretability thresholds. A three-alternative forced choice paradigm was used in conjunction with the method of adjustments to obtain a measure of the upper limen of display luminance contrast needed to interpret a complex display of primary flight information. The pattern of results and the absolute magnitudes of the luminance contrast settings were found to be in good agreement with previously reported data from psychophysical investigations of display luminance contrast requirements.
AMOLED (active matrix OLED) functionality and usable lifetime at temperature
NASA Astrophysics Data System (ADS)
Fellowes, David A.; Wood, Michael V.; Prache, Olivier; Jones, Susan
2005-05-01
Active Matrix Organic Light Emitting Diode (AMOLED) displays are known to exhibit high levels of performance, and these levels of performance have continually been improved over time with new materials and electronics design. eMagin Corporation developed a manually adjustable temperature compensation circuit with brightness control to allow for excellent performance over a wide temperature range. Night Vision and Electronic Sensors Directorate (US Army) tested the performance and survivability of a number of AMOLED displays in a temperature chamber over a range from -55°C to +85°C. Although device performance of AMOLEDs has always been its strong suit, the issue of usable display lifetimes for military applications continues to be an area of discussion and research. eMagin has made improvements in OLED materials and worked towards the development of a better understanding of usable lifetime for operation in a military system. NVESD ran luminance degradation tests of AMOLED panels at 50°C and at ambient to characterize the lifetime of AMOLED devices. The result is a better understanding of the applicability of AMOLEDs in military systems: where good fits are made, and where further development is needed.
A Succinct Overview of Virtual Reality Technology Use in Alzheimer’s Disease
García-Betances, Rebeca I.; Arredondo Waldmeyer, María Teresa; Fico, Giuseppe; Cabrera-Umpiérrez, María Fernanda
2015-01-01
We provide a brief review and appraisal of recent and current virtual reality (VR) technology for Alzheimer’s disease (AD) applications. We categorize them according to their intended purpose (e.g., diagnosis, patient cognitive training, caregivers’ education, etc.), focus feature (e.g., spatial impairment, memory deficit, etc.), methodology employed (e.g., tasks, games, etc.), immersion level, and passive or active interaction. Critical assessment indicates that most of them do not yet take full advantage of virtual environments with high levels of immersion and interaction. Many still rely on conventional 2D graphic displays to create non-immersive or semi-immersive VR scenarios. Important improvements are needed to make VR a better and more versatile assessment and training tool for AD. The use of the latest display technologies available, such as emerging head-mounted displays and 3D smart TV technologies, together with realistic multi-sensorial interaction devices, and neuro-physiological feedback capacity, are some of the most beneficial improvements this mini-review suggests. Additionally, it would be desirable that such VR applications for AD be easily and affordably transferable to in-home and nursing home environments. PMID:26029101
Flat-panel video resolution LED display system
NASA Astrophysics Data System (ADS)
Wareberg, P. G.; Kennedy, D. I.
The system consists of a 128 x 128 element X-Y addressable LED array fabricated from green-emitting gallium phosphide. The LED array is interfaced with a 128 x 128 matrix TV camera. Associated electronics provides for seven levels of grey scale above zero with a grey scale ratio of square root of 2. Picture elements are on 0.008 inch centers resulting in a resolution of 125 lines-per-inch and a display area of approximately 1 sq. in. The LED array concept lends itself to modular construction, permitting assembly of a flat panel screen of any desired size from 1 x 1 inch building blocks without loss of resolution. A wide range of prospective aerospace applications exist extending from helmet-mounted systems involving small dedicated arrays to multimode cockpit displays constructed as modular screens. High-resolution LED arrays are already used as CRT replacements in military film-marking reconnaissance applications.
NASA Technical Reports Server (NTRS)
Miranda, David J.; Santora, Joshua D.; Hochstadt, Jake
2017-01-01
Pamphlet on the IDEAS project for the Game Changing Development programs NASA booth at the Consumer Electronics Show. Pamphlet covers a high level overview of the technology developed and its capabilities. The technology being developed for the Integrated Display and Environmental Awareness System (IDEAS) project is a wearable computer system with an optical heads-up display (HUD) providing various means of communication and data manipulation to the user. The wearable computer, in the form of smart glasses, would allow personnel to view and modify critical information on a transparent, interactive display. This is presented in their unobstructed field of view, without taking their eyes or hands away from their critical work. The product is being designed in a modular manner so that the user can adjust the capabilities of the device depending on need. IDEAS is a full featured hardware and softwaresystem built to enhance the capabilities of theNASA work force on the ground and in space.
Wen, Jing; Tan, Song; Wang, Dhua; Zhao, Zhijun
2018-05-31
In the present study, we examined metabolic, morphological, and neurochemical changes in male striped hamsters (Cricetulus barabensis) in response to variations in food availability. Males with low and high levels of metabolic rate, MR (L-MR and H-MR), defined by their activity metabolic rates, were compared. In Experiment 1, 36-hrs food deprivation was found to significantly decrease MR levels, body fat content, mass of small and large intestines, and leptin gene expression in the white adipose tissues in male hamsters. Interestingly, L-MR males displayed decreased MR during both the day and night phases of circadian cycles, whereas H-MR males only showed a decrease in MR during the day (resting phase). These data indicate that individual differences in physical activity were associated with animal's different metabolic responses to food deprivation. In Experiment 2, both groups of males went through a 4-weeks fasting and re-feeding (re) paradigm. H-re males showed a persistent high level of MR, with a decreased body fat content and a trending decrease in leptin mRNA expression, compared to L-re males. Together, our data indicate that male striped hamsters with different levels of physical activity display altered, adaptive changes in response to variations in food availability. The neurochemical involvement of such adaptive changes needs to be further studied. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Expression of hypoxia-inducible carbonic anhydrases in brain tumors
Proescholdt, Martin A.; Mayer, Christina; Kubitza, Marion; Schubert, Thomas; Liao, Shu-Yuan; Stanbridge, Eric J.; Ivanov, Sergey; Oldfield, Edward H.; Brawanski, Alexander; Merrill, Marsha J.
2005-01-01
Malignant brain tumors exhibit distinct metabolic characteristics. Despite high levels of lactate, the intracellular pH of brain tumors is more alkaline than normal brain. Additionally, with increasing malignancy, brain tumors display intratumoral hypoxia. Carbonic anhydrase (CA) IX and XII are transmembrane isoenzymes that are induced by tissue hypoxia. They participate in regulation of pH homeostasis by catalyzing the reversible hydration of carbon dioxide. The aim of our study was to investigate whether brain tumors of different histology and grade of malignancy express elevated levels of CA IX and XII as compared to normal brain. We analyzed 120 tissue specimens from brain tumors (primary and metastatic) and normal brain for CA IX and XII expression by immunohistochemistry, Western blot, and in situ hybridization. Whereas normal brain tissue showed minimal levels of CA IX and XII expression, expression in tumors was found to be upregulated with increased level of malignancy. Hemangioblastomas, from patients with von Hippel–Lindau disease, also displayed high levels of CA IX and XII expression. Comparison of CA IX and XII staining with HIF-1α staining revealed a similar microanatomical distribution, indicating hypoxia as a major, but not the only, induction factor. The extent of CA IX and XII staining correlated with cell proliferation, as indicated by Ki67 labeling. The results demonstrate that CA IX and XII are upregulated in intrinsic and metastatic brain tumors as compared to normal brain tissue. This may contribute to the management of tumor-specific acid load and provide a therapeutic target. PMID:16212811
Event-Based Tone Mapping for Asynchronous Time-Based Image Sensor
Simon Chane, Camille; Ieng, Sio-Hoi; Posch, Christoph; Benosman, Ryad B.
2016-01-01
The asynchronous time-based neuromorphic image sensor ATIS is an array of autonomously operating pixels able to encode luminance information with an exceptionally high dynamic range (>143 dB). This paper introduces an event-based methodology to display data from this type of event-based imagers, taking into account the large dynamic range and high temporal accuracy that go beyond available mainstream display technologies. We introduce an event-based tone mapping methodology for asynchronously acquired time encoded gray-level data. A global and a local tone mapping operator are proposed. Both are designed to operate on a stream of incoming events rather than on time frame windows. Experimental results on real outdoor scenes are presented to evaluate the performance of the tone mapping operators in terms of quality, temporal stability, adaptation capability, and computational time. PMID:27642275
Protein composition of oil bodies from mature Brassica napus seeds.
Jolivet, Pascale; Boulard, Céline; Bellamy, Annick; Larré, Colette; Barre, Marion; Rogniaux, Hélène; d'Andréa, Sabine; Chardot, Thierry; Nesi, Nathalie
2009-06-01
Seed oil bodies (OBs) are intracellular particles storing lipids as food or biofuel reserves in oleaginous plants. Since Brassica napus OBs could be easily contaminated with protein bodies and/or myrosin cells, they must be purified step by step using floatation technique in order to remove non-specifically trapped proteins. An exhaustive description of the protein composition of rapeseed OBs from two double-zero varieties was achieved by a combination of proteomic and genomic tools. Genomic analysis led to the identification of sequences coding for major seed oil body proteins, including 19 oleosins, 5 steroleosins and 9 caleosins. Most of these proteins were also identified through proteomic analysis and displayed a high level of sequence conservation with their Arabidopsis thaliana counterparts. Two rapeseed oleosin orthologs appeared acetylated on their N-terminal alanine residue and both caleosins and steroleosins displayed a low level of phosphorylation.
Comparison of attitude information for helmet-mounted displays
NASA Astrophysics Data System (ADS)
Davy, Eleanor C.; Selcon, Stephen J.
1997-02-01
There are many potential uses of helmet-mounted displays (HMDs). One is to allow aircrew to spend increased time off- boresight scanning the outside world for threats or targets. Another is for acquiring a target and subsequently employing a weapon whilst looking off-boresight. An experiment was conducted to examine the use of HMDs for both these tasks using four different attitude displays: pitch ladder, cylinder, arc segmented attitude reference and roll-pitch. The task involved subjects flying a simulated low-level, high-speed mission which was divided into two phases. Phase one required subjects to scan off-boresight for air threats and acquire them by using the off-boresight capability of the HMD. Phase two required subjects to use the head-down display (HDD) to locate ground targets and use the HMD off- boresight capability to acquire them. Novel objective performance measures, designed specifically to evaluate HMD symbology, were collected. Overall, it was found that performance was superior when using the pitch ladder than other displays. This was supported by the subjective findings that it provided higher situational awareness than other displays. It was concluded that the advantage for the pitch ladder may have been due to having the same symbology on the HUD and HMD, enhancing smooth transitioning between the two displays. The importance of developing operationally relevant tasks and measures for the evaluation of HMDs are discussed and the implications of this research for future work are considered.
An Evaluation of Performance Characteristics of Primary Display Devices.
Ekpo, Ernest U; McEntee, Mark F
2016-04-01
The aim of this study was to complete a full evaluation of the new EIZO RX850 liquid crystal display and compare it to two currently used medical displays in Australia (EIZO GS510 and Barco MDCG 5121). The American Association of Physicists in Medicine (AAPM) Task Group 18 Quality Control test pattern was used to assess the performance of three high-resolution primary medical displays: EIZO RX850, EIZO GS510, and Barco MDCG 5121. A Konica Minolta spectroradiometer (CS-2000) was used to assess luminance response, non-uniformity, veiling glare, and color uniformity. Qualitative evaluation of noise was also performed. Seven breast lesions were displayed on each monitor and photographed with a calibrated 5.5-MP Olympus E-1 digital SLR camera. ImageJ software was used to sample pixel information from each lesion and surrounding background to calculate their conspicuity index on each of the displays. All monitor fulfilled all AAPM acceptance criteria. The performance characteristics for EIZO RX850, Barco MDCG 5121, and EIZO GS510 respectively were as follows: maximum luminance (490, 500.5, and 413 cd/m(2)), minimum luminance (0.724, 1.170, and 0.92 cd/m(2)), contrast ratio (675:1, 428:1, 449:1), just-noticeable difference index (635, 622, 609), non-uniformity (20, 5.92, and 8.5 %), veiling glare (GR = 2465.6, 720.4, 1249.8), and color uniformity (Δu'v' = +0.003, +0.002, +0.002). All monitors demonstrated low noise levels. The conspicuity index (χ) of the lesions was slightly higher in the EIZO RX850 display. All medical displays fulfilled AAPM performance criteria, and performance characteristics of EIZO RX850 are equal to or better than those of the Barco MDCG 5121 and EIZO GS510 displays.
Ocular Tolerance of Contemporary Electronic Display Devices.
Clark, Andrew J; Yang, Paul; Khaderi, Khizer R; Moshfeghi, Andrew A
2018-05-01
Electronic displays have become an integral part of life in the developed world since the revolution of mobile computing a decade ago. With the release of multiple consumer-grade virtual reality (VR) and augmented reality (AR) products in the past 2 years utilizing head-mounted displays (HMDs), as well as the development of low-cost, smartphone-based HMDs, the ability to intimately interact with electronic screens is greater than ever. VR/AR HMDs also place the display at much closer ocular proximity than traditional electronic devices while also isolating the user from the ambient environment to create a "closed" system between the user's eyes and the display. Whether the increased interaction with these devices places the user's retina at higher risk of damage is currently unclear. Herein, the authors review the discovery of photochemical damage of the retina from visible light as well as summarize relevant clinical and preclinical data regarding the influence of modern display devices on retinal health. Multiple preclinical studies have been performed with modern light-emitting diode technology demonstrating damage to the retina at modest exposure levels, particularly from blue-light wavelengths. Unfortunately, high-quality in-human studies are lacking, and the small clinical investigations performed to date have failed to keep pace with the rapid evolutions in display technology. Clinical investigations assessing the effect of HMDs on human retinal function are also yet to be performed. From the available data, modern consumer electronic displays do not appear to pose any acute risk to vision with average use; however, future studies with well-defined clinical outcomes and illuminance metrics are needed to better understand the long-term risks of cumulative exposure to electronic displays in general and with "closed" VR/AR HMDs in particular. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:346-354.]. Copyright 2018, SLACK Incorporated.
Humidification of unwrapped chilled meat on retail display using an ultrasonic fogging system.
Brown, Tim; Corry, Janet E L; Evans, Judith A
2007-12-01
The effects of an ultrasonic humidification system on unwrapped meat in a chilled retail display cabinet were assessed. Humidification raised the relative humidity of the cabinet air from a mean of 76.7% to just below saturation at 98.8%. This reduced the mean evaporative weight loss from whole samples of meat after 14h from 1.68% to 0.62% of their initial weight. The rate of deterioration in the appearance of the meat due to dehydration was reduced to the extent that while the unhumidified trial was terminated after 14h because all samples were judged to be unacceptable, the humidified trial was continued for 24h without any major changes in appearance. Levels of presumptive pseudomonas bacteria were relatively high in water samples taken from the humidification system and defrost water during the humidified trial, but Legionella spp. were not isolated. Significant increases in the numbers of bacteria on the meat during either trial were only found in one case, that of humidified minced beef. However, some of the samples had high counts even before display, and this may have masked any effect due to humidification. Differences in levels of air-borne contamination were small and inconsistent. Air temperatures were raised by humidification by between 1 and 2°C and this was reflected in similarly raised product temperatures. Temperatures of air leaving the evaporator indicated that this was due to icing of the evaporator in the periods leading up to defrosts.
Rittschof, Clare C
2017-01-01
In highly structured societies, individuals behave flexibly and cooperatively in order to achieve a particular group-level outcome. However, even in social species, environmental inputs can have long lasting effects on individual behavior, and variable experiences can even result in consistent individual differences and constrained behavioral flexibility. Despite the fact that such constraints on behavior could have implications for behavioral optimization at the social group level, few studies have explored how social experiences accumulate over time, and the mechanistic basis of these effects. In the current study, I evaluate how sequential social experiences affect individual and group level aggressive phenotypes, and individual brain gene expression, in the highly social honey bee ( Apis mellifera ). To do this, I combine a whole colony chronic predator disturbance treatment with a lab-based manipulation of social group composition. Compared to the undisturbed control, chronically disturbed individuals show lower aggression levels overall, but also enhanced behavioral flexibility in the second, lab-based social context. Disturbed bees display aggression levels that decline with increasing numbers of more aggressive, undisturbed group members. However, group level aggressive phenotypes are similar regardless of the behavioral tendencies of the individuals that make up the group, suggesting a combination of underlying behavioral tendency and negative social feedback influences the aggressive behaviors displayed, particularly in the case of disturbed individuals. An analysis of brain gene expression showed that aggression related biomarker genes reflect an individual's disturbance history, but not subsequent social group experience or behavioral outcomes. In highly social animals with collective behavioral phenotypes, social context may mask underlying variation in individual behavioral tendencies. Moreover, gene expression patterns may reflect behavioral tendency, while behavioral outcomes are further regulated by social cues perceived in real-time.
Pyruvate cycling and implications for regulation of gluconeogenesis in the insect, Manduca sexta L.
Thompson, S N
2000-08-11
Pyruvate cycling was examined in the insect Manduca sexta L. (2-(13)C)pyruvate was injected into 5th instar larvae maintained on a semisynthetic high sucrose, low sucrose, or sucrose-free diet. Pyruvate cycling and gluconeogenesis were determined from the distribution of (13)C in blood metabolites, including trehalose, the blood sugar of insects, and alanine. Pyruvate cycling was evident from the (13)C enrichment of alanine C3, synthesized by transamination of pyruvate following carboxylation to oxaloacetate and cycling through phosphoenolpyruvate. Based on the relative (13)C enrichments of alanine C2 and C3, insects maintained on the high sucrose diet displayed higher levels of cycling than insects on the other diets. Insects on all the diets, when subsequently starved, displayed low levels of cycling. Gluconeogenesis was evident in insects on sucrose-free or low sucrose diets from the selective (13)C enrichment in trehalose. The level of gluconeogenesis relative to glycolysis was indicated by the (13)C enrichment of trehalose C6 and alanine C3, both enrichments metabolically derived in the same manner. Insects starved after maintenance on the sucrose-free or low sucrose diets remained glucogenic. Insects on the high sucrose diet were not glucogenic, and subsequent starvation did not induce gluconeogenesis. The results indicate that pyruvate kinase plays a critical role in regulating the gluconeogenic/glycolytic balance, and that inhibition of pyruvate kinase is a principal regulatory event during induction of de novo trehalose synthesis. Gluconeogenesis failed to maintain homeostatic levels of blood trehalose, supporting the conclusion that blood sugar level may be important for mediating nutrient intake. Possible factors involved in the regulation of gluconeogenesis in insects are discussed. Copyright 2000 Academic Press.
A subjective evaluation of high-chroma color with wide color-gamut display
NASA Astrophysics Data System (ADS)
Kishimoto, Junko; Yamaguchi, Masahiro; Ohyama, Nagaaki
2009-01-01
Displays tends to expand its color gamut, such as multi-primary color display, Adobe RGB and so on. Therefore displays got possible to display high chroma colors. However sometimes, we feel unnatural some for the image which only expanded chroma. Appropriate gamut mapping method to expand color gamut is not proposed very much. We are attempting preferred expanded color reproduction on wide color gamut display utilizing high chroma colors effectively. As a first step, we have conducted an experiment to investigate the psychological effect of color schemes including highly saturated colors. We used the six-primary-color projector that we have developed for the presentation of test colors. The six-primary-color projector's gamut volume in CIELAB space is about 1.8 times larger than the normal RGB projector. We conducted a subjective evaluation experiment using the SD (Semantic Differential) technique to find the quantitative psychological effect of high chroma colors.
Mazerolles, Fabienne; Stolzenberg, Marie-Claude; Pelle, Olivier; Picard, Capucine; Neven, Benedicte; Fischer, Alain; Magerus-Chatinet, Aude; Rieux-Laucat, Frederic
2018-01-01
Autoimmune lymphoproliferative syndrome (ALPS) with FAS mutation (ALPS-FAS) is a nonmalignant, noninfectious, lymphoproliferative disease with autoimmunity. Given the central role of natural regulatory T cells (nTregs) in the control of lymphoproliferation and autoimmunity, we assessed nTreg-suppressive function in 16 patients with ALPS-FAS. The proportion of CD25 high CD127 low Tregs was lower in ALPS-FAS patients than in healthy controls. This subset was correlated with a reduced CD25 expression in CD3 + CD4 + T cells from ALPS patients and thus an abnormally low proportion of CD25 high FOXP3 + Helios + T cells. The ALPS patients also displayed a high proportion of naïve Treg (FOXP3 low CD45RA + ) and an unusual subpopulation (CD4 + CD127 low CD15s + CD45RA + ). Despite this abnormal phenotype, the CD25 high CD127 low Tregs' suppressive function was unaffected. Furthermore, conventional T cells from FAS -mutated patients showed normal levels of sensitivity to Treg suppression. An abnormal Treg phenotype is observed in circulating lymphocytes of ALPS patients. However, these Tregs displayed a normal suppressive function on T effector proliferation in vitro . This is suggesting that lymphoproliferation observed in ALPS patients does not result from Tregs functional defect or T effector cells insensitivity to Tregs suppression.
Thieme, Kati; Turk, Dennis C; Gracely, Richard H; Maixner, William; Flor, Herta
2015-02-01
This study examined the relationship of psychophysiological response patterns in fibromyalgia with psychological characteristics and comorbid mental disorders. Surface electromyographic data, systolic and diastolic blood pressure, heart rate (HR), and skin conductance levels were recorded continuously during baseline, stress, and relaxation tasks. Cluster analysis revealed 4 subgroups of patients who differed on pain characteristics and cognitive, affective, and behavioral responses to pain and stress. The largest group (46.7%) was characterized by elevated blood pressure levels and stress reactivity (a disposition assumed to be a vulnerability factor for the development of diseases) associated with pain, anxiety, physical interference, low activity, and pain behaviors. A second group (41.6%) showed low baseline blood pressure and reactivity, and high activity and stress. A third group (9.2%) displayed high baseline skin conductance level, reactivity, and depression, and a fourth small group (2.5%) displayed elevated baseline electromyographic response and reactivity with high levels of anxiety and depression. These data suggest that unique psychophysiological response patterns are associated with psychological coping and mental disorders in fibromyalgia patients. The identification of the mechanisms that contribute to these group differences will further our understanding of the mechanisms involved in the development and maintenance of fibromyalgia and suggest differential treatment strategies. This article presents psychological characteristics and comorbidity with mental disorders of psychophysiological subgroups of fibromyalgia patients. This mechanistic analysis will assist scientific identification of systems-based pathways that contribute to autonomic and stress mechanisms that mediate chronic pain. Demonstration of distinct, homogeneous subgroups is an important step towards personalized, mechanism-oriented treatments. Copyright © 2015 American Pain Society. All rights reserved.
Universal power law of the gravity wave manifestation in the AIM CIPS polar mesospheric cloud images
NASA Astrophysics Data System (ADS)
Rong, Pingping; Yue, Jia; Russell, James M., III; Siskind, David E.; Randall, Cora E.
2018-01-01
We aim to extract a universal law that governs the gravity wave manifestation in polar mesospheric clouds (PMCs). Gravity wave morphology and the clarity level of display vary throughout the wave population manifested by the PMC albedo data. Higher clarity refers to more distinct exhibition of the features, which often correspond to larger variances and a better-organized nature. A gravity wave tracking algorithm based on the continuous Morlet wavelet transform is applied to the PMC albedo data at 83 km altitude taken by the Aeronomy of Ice in the Mesosphere (AIM) Cloud Imaging and Particle Size (CIPS) instrument to obtain a large ensemble of the gravity wave detections. The horizontal wavelengths in the range of ˜ 20-60 km are the focus of the study. It shows that the albedo (wave) power statistically increases as the background gets brighter. We resample the wave detections to conform to a normal distribution to examine the wave morphology and display clarity beyond the cloud brightness impact. Sample cases are selected at the two tails and the peak of the normal distribution to represent the full set of wave detections. For these cases the albedo power spectra follow exponential decay toward smaller scales. The high-albedo-power category has the most rapid decay (i.e., exponent = -3.2) and corresponds to the most distinct wave display. The wave display becomes increasingly blurrier for the medium- and low-power categories, which hold the monotonically decreasing spectral exponents of -2.9 and -2.5, respectively. The majority of waves are straight waves whose clarity levels can collapse between the different brightness levels, but in the brighter background the wave signatures seem to exhibit mildly turbulent-like behavior.
Roeloffs, E.; Quilty, E.
1997-01-01
Two of the four wells monitored near Parkfield, California, during 1985 showed water level rises beginning three days before the M4 6.1 Kettleman Hills earthquake. In one of these wells, the 3.0 cm rise was nearly unique in five years of water level data. However, in the other well, which showed a 3.8 cm rise, many other changes of comparable size have been observed. Both wells that did not display pre-earthquake rises tap partially confined aquifers that cannot sustain pressure changes due to tectonic strain having periods longer than several days. We evaluate the effect of partial aquifer confinement on the ability of these four wells to display water level changes in response to aquifer strain. Although the vertical hydraulic diffusivities cannot be determined uniquely, we can find a value of diffusivity for each site that is consistent with the site's tidal and barometric responses as well as with the rate of partial recovery of the coseismic water level drops. Furthermore, the diffusivity for one well is high enough to explain why the preseismic rise could not have been detected there. For the fourth well, the diffusivity is high enough to have reduced the size of the preseismic signal as much as 50%, although it should still have been detectable. Imperfect confinement cannot explain the persistent water level changes in the two partially confined aquifers, but it does show that they were not due to volume strain. The pre-earthquake water level rises may have been precursors to the Kettleman Hills earthquake. If so, they probably were not caused by accelerating slip over the part of the fault plane that ruptured in that earthquake because they are of opposite sign to the observed coseismic water level drops.
Nishijo, Muneko; Tai, Pham The; Anh, Nguyen Thi Nguyet; Nghi, Tran Ngoc; Nakagawa, Hideaki; Van Luong, Hoang; Anh, Tran Hai; Morikawa, Yuko; Waseda, Tomoo; Kido, Teruhiko; Nishijo, Hisao
2015-01-01
In our previous study of 3-year-old children in a dioxin contamination hot spot in Vietnam, the high total dioxin toxic equivalent (TEQ-PCDDs/Fs)-exposed group during the perinatal period displayed lower Bayley III neurodevelopmental scores, whereas the high 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD)-exposed group displayed increased autistic traits. In autistic children, urinary amino acid profiles have revealed metabolic alterations in the amino acids that serve as neurotransmitters in the developing brain. Therefore, our present study aimed to investigate the use of alterations in urinary amino acid excretion as biomarkers of dioxin exposure-induced neurodevelopmental deficits in highly exposed 3-year-old children in Vietnam. A nested case-control study of urinary analyses was performed for 26 children who were selected from 111 3-year-old children whose perinatal dioxin exposure levels and neurodevelopmental status were examined in follow-up surveys conducted in a dioxin contaminated hot spot. We compared urinary amino acid levels between the following 4 groups: (1) a high TEQ-PCDDs/Fs and high TCDD-exposed group; (2) a high TEQ-PCDDs/Fs but low TCDD-exposed group; (3) a low TEQ-PCDDs/Fs exposed and poorly developed group; and (4) a low TEQ-PCDDs/Fs exposed and well-developed group. Urinary levels of histidine and tryptophan were significantly decreased in the high TEQ-PCDDs/Fs and high TCDD group, as well as in the high TEQ-PCDDs/Fs but low TCDD group, compared with the low TEQ-PCDDs/Fs and well-developed group. However, the ratio of histidine to glycine was significantly lower only in the high TEQ-PCDDs/Fs and high TCDD group. Furthermore, urinary histidine levels and the ratio of histidine to glycine were significantly correlated with neurodevelopmental scores, particularly for language and fine motor skills. These results indicate that urinary histidine is specifically associated with dioxin exposure-induced neurodevelopmental deficits, suggesting that urinary histidine may be a useful marker of dioxin-induced neurodevelopmental deficits and that histaminergic neurotransmission may be an important pathological contributor to dioxin-mediated neurotoxicity. PMID:25584822
Nishijo, Muneko; Tai, Pham The; Anh, Nguyen Thi Nguyet; Nghi, Tran Ngoc; Nakagawa, Hideaki; Van Luong, Hoang; Anh, Tran Hai; Morikawa, Yuko; Waseda, Tomoo; Kido, Teruhiko; Nishijo, Hisao
2015-01-01
In our previous study of 3-year-old children in a dioxin contamination hot spot in Vietnam, the high total dioxin toxic equivalent (TEQ-PCDDs/Fs)-exposed group during the perinatal period displayed lower Bayley III neurodevelopmental scores, whereas the high 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD)-exposed group displayed increased autistic traits. In autistic children, urinary amino acid profiles have revealed metabolic alterations in the amino acids that serve as neurotransmitters in the developing brain. Therefore, our present study aimed to investigate the use of alterations in urinary amino acid excretion as biomarkers of dioxin exposure-induced neurodevelopmental deficits in highly exposed 3-year-old children in Vietnam. A nested case-control study of urinary analyses was performed for 26 children who were selected from 111 3-year-old children whose perinatal dioxin exposure levels and neurodevelopmental status were examined in follow-up surveys conducted in a dioxin contaminated hot spot. We compared urinary amino acid levels between the following 4 groups: (1) a high TEQ-PCDDs/Fs and high TCDD-exposed group; (2) a high TEQ-PCDDs/Fs but low TCDD-exposed group; (3) a low TEQ-PCDDs/Fs exposed and poorly developed group; and (4) a low TEQ-PCDDs/Fs exposed and well-developed group. Urinary levels of histidine and tryptophan were significantly decreased in the high TEQ-PCDDs/Fs and high TCDD group, as well as in the high TEQ-PCDDs/Fs but low TCDD group, compared with the low TEQ-PCDDs/Fs and well-developed group. However, the ratio of histidine to glycine was significantly lower only in the high TEQ-PCDDs/Fs and high TCDD group. Furthermore, urinary histidine levels and the ratio of histidine to glycine were significantly correlated with neurodevelopmental scores, particularly for language and fine motor skills. These results indicate that urinary histidine is specifically associated with dioxin exposure-induced neurodevelopmental deficits, suggesting that urinary histidine may be a useful marker of dioxin-induced neurodevelopmental deficits and that histaminergic neurotransmission may be an important pathological contributor to dioxin-mediated neurotoxicity.
Løset, Geir Åge; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger
2011-02-24
Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before.
NASA Astrophysics Data System (ADS)
Zhang, L.; Cong, Y.; Wu, C.; Bai, C.; Wu, C.
2017-08-01
The recording of Architectural heritage information is the foundation of research, conservation, management, and the display of architectural heritage. In other words, the recording of architectural heritage information supports heritage research, conservation, management and architectural heritage display. What information do we record and collect and what technology do we use for information recording? How do we determine the level of accuracy required when recording architectural information? What method do we use for information recording? These questions should be addressed in relation to the nature of the particular heritage site and the specific conditions for the conservation work. In recent years, with the rapid development of information acquisition technology such as Close Range Photogrammetry, 3D Laser Scanning as well as high speed and high precision Aerial Photogrammetry, many Chinese universities, research institutes and heritage management bureaux have purchased considerable equipment for information recording. However, the lack of understanding of both the nature of architectural heritage and the purpose for which the information is being collected has led to several problems. For example: some institutions when recording architectural heritage information aim solely at high accuracy. Some consider that advanced measuring methods must automatically replace traditional measuring methods. Information collection becomes the purpose, rather than the means, of architectural heritage conservation. Addressing these issues, this paper briefly reviews the history of architectural heritage information recording at the Summer Palace (Yihe Yuan, first built in 1750), Beijing. Using the recording practices at the Summer Palace during the past ten years as examples, we illustrate our achievements and lessons in recording architectural heritage information with regard to the following aspects: (buildings') ideal status desired, (buildings') current status, structural distortion analysis, display, statue restoration and thematic research. Three points will be highlighted in our discussion: 1. Understanding of the heritage is more important than the particular technology used: Architectural heritage information collection and recording are based on an understanding of the value and nature of the architectural heritage. Understanding is the purpose, whereas information collection and recording are the means. 2. Demand determines technology: Collecting and recording architectural heritage information is to serve the needs of heritage research, conservation, management and display. These different needs determine the different technologies that we use. 3. Set the level of accuracy appropriately: For information recording, high accuracy is not the key criterion; rather an appropriate level of accuracy is key. There is considerable deviation between the nominal accuracy of any instrument and the accuracy of any particular measurement.
Validation of tablet-based evaluation of color fundus images
Christopher, Mark; Moga, Daniela C.; Russell, Stephen R.; Folk, James C.; Scheetz, Todd; Abràmoff, Michael D.
2012-01-01
Purpose To compare diabetic retinopathy (DR) referral recommendations made by viewing fundus images using a tablet computer to recommendations made using a standard desktop display. Methods A tablet computer (iPad) and a desktop PC with a high-definition color display were compared. For each platform, two retinal specialists independently rated 1200 color fundus images from patients at risk for DR using an annotation program, Truthseeker. The specialists determined whether each image had referable DR, and also how urgently each patient should be referred for medical examination. Graders viewed and rated the randomly presented images independently and were masked to their ratings on the alternative platform. Tablet- and desktop display-based referral ratings were compared using cross-platform, intra-observer kappa as the primary outcome measure. Additionally, inter-observer kappa, sensitivity, specificity, and area under ROC (AUC) were determined. Results A high level of cross-platform, intra-observer agreement was found for the DR referral ratings between the platforms (κ=0.778), and for the two graders, (κ=0.812). Inter-observer agreement was similar for the two platforms (κ=0.544 and κ=0.625 for tablet and desktop, respectively). The tablet-based ratings achieved a sensitivity of 0.848, a specificity of 0.987, and an AUC of 0.950 compared to desktop display-based ratings. Conclusions In this pilot study, tablet-based rating of color fundus images for subjects at risk for DR was consistent with desktop display-based rating. These results indicate that tablet computers can be reliably used for clinical evaluation of fundus images for DR. PMID:22495326
Kramer, Uwe; Rizos, Konstantin; Apfel, Heiko; Autenrieth, Ingo B.; Lattemann, Claus T.
2003-01-01
To optimize antigen delivery by Salmonella vaccine strains, a system for surface display of antigenic determinants was established by using the autotransporter secretion pathway of gram-negative bacteria. A modular system for surface display allowed effective targeting of heterologous antigens or fragments thereof to the bacterial surface by the autotransporter domain of AIDA-I, the Escherichia coli adhesin involved in diffuse adherence. A major histocompatibility complex class II-restricted epitope, comprising amino acids 74 to 86 of the Yersinia enterocolitica heat shock protein Hsp60 (Hsp6074-86), was fused to the AIDA-I autotransporter domain, and the resulting fusion protein was expressed at high levels on the cell surface of E. coli and Salmonella enterica serovar Typhimurium. Colonization studies in mice vaccinated with Salmonella strains expressing AIDA-I fusion proteins demonstrated high genetic stability of the generated vaccine strain in vivo. Furthermore, a pronounced T-cell response against Yersinia Hsp6074-86 was induced in mice vaccinated with a Salmonella vaccine strain expressing the Hsp6074-86-AIDA-I fusion protein. This was shown by monitoring Yersinia Hsp60-stimulated IFN-γ secretion and proliferation of splenic T cells isolated from vaccinated mice. These results demonstrate that the surface display of antigenic determinants by the autotransporter pathway deserves special attention regarding the application in live attenuated Salmonella vaccine strains. PMID:12654812
Kramer, Uwe; Rizos, Konstantin; Apfel, Heiko; Autenrieth, Ingo B; Lattemann, Claus T
2003-04-01
To optimize antigen delivery by Salmonella vaccine strains, a system for surface display of antigenic determinants was established by using the autotransporter secretion pathway of gram-negative bacteria. A modular system for surface display allowed effective targeting of heterologous antigens or fragments thereof to the bacterial surface by the autotransporter domain of AIDA-I, the Escherichia coli adhesin involved in diffuse adherence. A major histocompatibility complex class II-restricted epitope, comprising amino acids 74 to 86 of the Yersinia enterocolitica heat shock protein Hsp60 (Hsp60(74-86)), was fused to the AIDA-I autotransporter domain, and the resulting fusion protein was expressed at high levels on the cell surface of E. coli and Salmonella enterica serovar Typhimurium. Colonization studies in mice vaccinated with Salmonella strains expressing AIDA-I fusion proteins demonstrated high genetic stability of the generated vaccine strain in vivo. Furthermore, a pronounced T-cell response against Yersinia Hsp60(74-86) was induced in mice vaccinated with a Salmonella vaccine strain expressing the Hsp60(74-86)-AIDA-I fusion protein. This was shown by monitoring Yersinia Hsp60-stimulated IFN-gamma secretion and proliferation of splenic T cells isolated from vaccinated mice. These results demonstrate that the surface display of antigenic determinants by the autotransporter pathway deserves special attention regarding the application in live attenuated Salmonella vaccine strains.
Ultrascale collaborative visualization using a display-rich global cyberinfrastructure.
Jeong, Byungil; Leigh, Jason; Johnson, Andrew; Renambot, Luc; Brown, Maxine; Jagodic, Ratko; Nam, Sungwon; Hur, Hyejung
2010-01-01
The scalable adaptive graphics environment (SAGE) is high-performance graphics middleware for ultrascale collaborative visualization using a display-rich global cyberinfrastructure. Dozens of sites worldwide use this cyberinfrastructure middleware, which connects high-performance-computing resources over high-speed networks to distributed ultraresolution displays.
Stepanian, L S; Grigorian, V G; Stepanian, A Iu
2010-01-01
The influence of virtual aggressogenic environment on psychoemotional sphere of male and female teenagers with different levels of personal aggression was studied by characteristics of the heart rate. The exposure to the aggressogenic factors produced a change of the centralized control for the autonomic control in female and male teenagers with the high level of aggression and females with the low level of aggression. Male teenagers with the low level of aggression displayed the prevalence of the centralized control. Thus, the influence of exposure of teenagers to the virtual aggressogenic environment was shown to be ambiguous depending on the level of the level of personal aggression and gender.
Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display
NASA Astrophysics Data System (ADS)
Nelson, Scott A.
1994-06-01
The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.
Strategies for Filling a Performance Gap between Practice and High-Level Competition
ERIC Educational Resources Information Center
Wang, Jin
2010-01-01
Many athletes display great sport skills in noncompetitive situations such as during practice, but fail to successfully execute these same skills in competition. Coaches often wonder (1) from a technical perspective, why is the good performance of athletes during practice sessions not transferred to actual competition; (2) what are the flaws of…
ERIC Educational Resources Information Center
Rose, John; Willner, Paul; Shead, Jennifer; Jahoda, Andrew; Gillespie, David; Townson, Julia; Lammie, Claire; Woodgate, Christopher; Stenfert Kroese, Biza; Felce, David; MacMahon, Pamela; Rose, Nikki; Stimpson, Aimee; Nuttall, Jacqueline; Hood, Kerenza
2013-01-01
Background: Many people with intellectual disabilities display high levels of anger, and cognitive-behavioural anger management interventions are used routinely. However, for these methods to be used optimally, a better understanding is needed of different forms of anger assessment. The aim of this study was to investigate the relationship of a…
How Do Some Students Overcome Their Socio-Economic Background? PISA in Focus. No. 5
ERIC Educational Resources Information Center
OECD Publishing (NJ1), 2011
2011-01-01
Are socio-economically disadvantaged students condemned to perpetuate an intergenerational cycle of poor academic achievement, poor job prospects and poverty? Not if they attend schools that provide them with more regular classes. Resilient students in the 2006 and 2009 PISA surveys displayed high levels of academic achievement despite the fact…
ERIC Educational Resources Information Center
Radley, Keith C.; Dart, Evan H.; O'Handley, Roderick D.
2016-01-01
The current study investigated the effectiveness of the Quiet Classroom Game, an interdependent group contingency using an iPad loaded with a decibel meter app, for increasing academically engaged behavior. Three first-grade classrooms in the southeastern United States, identified as displaying high levels of noise and disruptive behavior, were…
Parents of Children with Autism Spectrum Disorders: Accessed and Preferred Parental Supports
ERIC Educational Resources Information Center
Morrison, Susan Tinker
2013-01-01
Rates of autism are rising at an alarming rate; one child out of every 88 live births will have an autism spectrum disorder (ASD). A child with an ASD displays significant deficits in social skills, communication, and behavior, often resulting in high parental stress levels. Parents usually experience increased stress caring for a child with…
When Errors Count: An EEG Study on Numerical Error Monitoring under Performance Pressure
ERIC Educational Resources Information Center
Schillinger, Frieder L.; De Smedt, Bert; Grabner, Roland H.
2016-01-01
In high-stake tests, students often display lower achievements than expected based on their skill level--a phenomenon known as choking under pressure. This imposes a serious problem for many students, especially for test-anxious individuals. Among school subjects, mathematics has been shown to be particularly vulnerable to choking. To succeed in a…
Training and Transfer of Training in Rapid Visual Search for Camouflaged Targets
Neider, Mark B.; Ang, Cher Wee; Voss, Michelle W.; Carbonari, Ronald; Kramer, Arthur F.
2013-01-01
Previous examinations of search under camouflage conditions have reported that performance improves with training and that training can engender near perfect transfer to similar, but novel camouflage-type displays [1]. What remains unclear, however, are the cognitive mechanisms underlying these training improvements and transfer benefits. On the one hand, improvements and transfer benefits might be associated with higher-level overt strategy shifts, such as through the restriction of eye movements to target-likely (background) display regions. On the other hand, improvements and benefits might be related to the tuning of lower-level perceptual processes, such as figure-ground segregation. To decouple these competing possibilities we had one group of participants train on camouflage search displays and a control group train on non-camouflage displays. Critically, search displays were rapidly presented, precluding eye movements. Before and following training, all participants completed transfer sessions in which they searched novel displays. We found that search performance on camouflage displays improved with training. Furthermore, participants who trained on camouflage displays suffered no performance costs when searching novel displays following training. Our findings suggest that training to break camouflage is related to the tuning of perceptual mechanisms and not strategic shifts in overt attention. PMID:24386301
Large Terrain Continuous Level of Detail 3D Visualization Tool
NASA Technical Reports Server (NTRS)
Myint, Steven; Jain, Abhinandan
2012-01-01
This software solved the problem of displaying terrains that are usually too large to be displayed on standard workstations in real time. The software can visualize terrain data sets composed of billions of vertices, and can display these data sets at greater than 30 frames per second. The Large Terrain Continuous Level of Detail 3D Visualization Tool allows large terrains, which can be composed of billions of vertices, to be visualized in real time. It utilizes a continuous level of detail technique called clipmapping to support this. It offloads much of the work involved in breaking up the terrain into levels of details onto the GPU (graphics processing unit) for faster processing.
Wright, Alison J; Whitwell, Sophia C L; Takeichi, Chika; Hankins, Matthew; Marteau, Theresa M
2009-02-01
Numeracy, the ability to process basic mathematical concepts, may affect responses to graphical displays of health risk information. Displays of probabilistic risk information using grouped dots are easier to understand than displays using dispersed dots. However, dispersed dots may better convey the randomness with which health threats occur, so increasing perceived susceptibility. We hypothesized that low numeracy participants would better understand risks presented using grouped dot displays, while high numeracy participants would have good understanding, regardless of display type. Moreover, we predicted that dispersed dot displays, in contrast to grouped dot displays, would increase risk perceptions and worry only for highly numerate individuals. One hundred and forty smokers read vignettes asking them to imagine being at risk of Crohn's disease, in a 2(display type: dispersed/grouped dots) x 3(risk magnitude: 3%/6%/50%) x 2(numeracy: high/low) design. They completed measures of risk comprehension, perceived susceptibility and worry. More numerate participants had better objective risk comprehension, but this effect was not moderated by display type. There was marginally significant support for the predicted numeracy x display type interaction for worry about Crohn's disease, but not for perceived susceptibility to the condition. Dispersed dot displays somewhat increase worry in highly numerate individuals, but only numeracy influenced objective risk comprehension. The most effective display type for communicating risk information will depend on the numeracy of the population and the goal(s) of the communication.
New generation of 3D desktop computer interfaces
NASA Astrophysics Data System (ADS)
Skerjanc, Robert; Pastoor, Siegmund
1997-05-01
Today's computer interfaces use 2-D displays showing windows, icons and menus and support mouse interactions for handling programs and data files. The interface metaphor is that of a writing desk with (partly) overlapping sheets of documents placed on its top. Recent advances in the development of 3-D display technology give the opportunity to take the interface concept a radical stage further by breaking the design limits of the desktop metaphor. The major advantage of the envisioned 'application space' is, that it offers an additional, immediately perceptible dimension to clearly and constantly visualize the structure and current state of interrelations between documents, videos, application programs and networked systems. In this context, we describe the development of a visual operating system (VOS). Under VOS, applications appear as objects in 3-D space. Users can (graphically connect selected objects to enable communication between the respective applications. VOS includes a general concept of visual and object oriented programming for tasks ranging from, e.g., low-level programming up to high-level application configuration. In order to enable practical operation in an office or at home for many hours, the system should be very comfortable to use. Since typical 3-D equipment used, e.g., in virtual-reality applications (head-mounted displays, data gloves) is rather cumbersome and straining, we suggest to use off-head displays and contact-free interaction techniques. In this article, we introduce an autostereoscopic 3-D display and connected video based interaction techniques which allow viewpoint-depending imaging (by head tracking) and visually controlled modification of data objects and links (by gaze tracking, e.g., to pick, 3-D objects just by looking at them).
A new helper phage for improved monovalent display of Fab molecules.
Beaber, John W; Tam, Eric M; Lao, Llewelyn S; Rondon, Isaac J
2012-02-28
Phage display technology is a powerful tool for the identification of novel antibodies for drug discovery. Phage display libraries have been constructed with massive diversity, but their use may be hindered by limited antibody display levels when rescued with the M13KO7 helper phage. Variants of M13KO7 have been constructed previously that increase the levels of display of rescued phage, but all produce phage that display multiple copies of the antibody fragment on their surface and have reduced titer and infectivity. In this study, we describe a new helper phage, XP5, which increased the display level of Fab molecules more than two-fold compared to phage rescued with M13KO7. XP5 uses a combination of ribosome binding site spacing alterations and rare codon clusters to reduce the expression of pIII from the helper phage. This reduction in pIII expression leads to an increase in the incorporation of pIII-Fab fusions during phage rescue. The rescued phage displayed a single copy of the Fab molecule, preventing any avidity effects during the selection process. This also suggests that the percentage of the population of phage displaying a Fab molecule is increased when rescued with XP5. Additionally, the phage titers and infectivity are comparable to libraries rescued with M13KO7. After two rounds of panning we observed a nearly 5-fold increase in the number of antigen binding Fab molecules compared to panning conducted with the same library rescued with M13KO7. The nature of the mutations in XP5 makes it a universal substitute for M13KO7 in pIII-based phage display, compatible with most phagemids and bacterial strains. Copyright © 2011 Elsevier B.V. All rights reserved.
Smith, Kristopher M; Apicella, Coren L
2017-06-01
A contribution to a special issue on Hormones and Human Competition. The effect of postural power displays (i.e. power poses) on hormone levels and decision-making has recently been challenged. While Carney et al. (2010) found that holding brief postural displays of power leads to increased testosterone, decreased cortisol and greater economic risk taking, this failed to replicate in a recent high-powered study (Ranehill et al. 2015). It has been put forward that subtle differences in social context may account for the differences in results. Power displays naturally occur within the context of competitions, as do changes in hormones, and researchers have yet to examine the effects of poses within this ecologically relevant context. Using a large sample of 247 male participants, natural winners and losers of a physical competition were randomly assigned to hold a low, neutral or high-power postural display. We found no main effect of pose type on testosterone, cortisol, risk or feelings of power. Winners assigned to a high-power pose had a relative, albeit small, rise in testosterone compared to winners who held neutral or low-power poses. For losers, we found little evidence that high-power poses lead to increased testosterone relative to those holding neutral or low-powered poses. If anything, the reverse was observed - losers had a reduction in testosterone after holding high-power poses. To the extent that changes in testosterone modulate social behaviors adaptively, it is possible that the relative reduction in testosterone observed in losers taking high-powered poses is designed to inhibit further "winner-like" behavior that could result in continued defeat and harm. Still, effects were small, multiple comparisons were made, and the results ran counter to our predictions. We thus treat these conclusions as preliminary. Copyright © 2016 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The removal of Varroa destructor was assessed in Russian honey bee (RHB) colonies with known levels of Varroa Sensitive Hygienic (VSH) and brood removal activities. The expression of grooming behaviour using individual bees was also measured using three groups of RHB displaying different VSH levels:...
Melendez-Ferro, Miguel; Perez-Costas, Emma; Glover, Matthew E.; Jackson, Nateka L.; Stringfellow, Sara A.; Pugh, Phyllis C.; Fant, Andrew D.; Clinton, Sarah M.
2016-01-01
Individual differences in human temperament can increase risk for psychiatric disorders like depression and anxiety. Our laboratory utilized a rat model of temperamental differences to assess neurodevelopmental factors underlying emotional behavior differences. Rats selectively bred for low novelty exploration (Low Responders, LR) display high levels of anxiety- and depression-like behavior compared to High Novelty Responder (HR) rats. Using transcriptome profiling, the present study uncovered vast gene expression differences in the early postnatal HR versus LR limbic brain, including changes in genes involved in cellular metabolism. These data led us to hypothesize that rats prone to high (versus low) anxiety/depression-like behavior exhibit distinct patterns of brain metabolism during the first weeks of life, which may reflect disparate patterns of synaptogenesis and brain circuit development. Thus, in a second experiment we examined activity of Cytochrome C Oxidase (COX), an enzyme responsible for ATP production and a correlate of metabolic activity, to explore functional energetic differences in HR/LR early postnatal brain. We found that HR rats display higher COX activity in the amygdala and specific hippocampal subregions compared to LRs during the first 2 weeks of life. Correlational analysis examining COX levels across several brain regions and multiple early postnatal time points suggested desynchronization in the developmental timeline of the limbic HR versus LR brain during the first two postnatal weeks. These early divergent COX activity levels may reflect altered circuitry or synaptic activity in the early postnatal HR/LR brain, which could contribute to the emergence of their distinct behavioral phenotypes. PMID:26979051
Jain, Khushbu; Sharma, Schweta; Prajna, Samani Chaitanya; Jain, Viney
2018-01-01
Increasing antisocial and violent behaviors in adolescents and young adults present serious challenges for public health. Children with persistent high levels of aggressiveness are often associated with developing conduct disorders later in life. Early detection of highly aggressive children and sociodemographic risk-modifying factors are important for developing effective preventive strategies. The present study was undertaken to assess levels of aggressiveness for detecting highly aggressive children in sample populations of primary school children in an urban setting and determine significant biosociocultural risk-modifying factors in this scenario. The study was conducted during August-September, 2015 in 5 primary schools of South Delhi Municipal Corporation. Sociodemographic data on 2080 students were collected. Overall aggressiveness scores (OA-Scores) were estimated using a self-report questionnaire in Hindi. Categorizing students according to their OA-Scores, the data revealed that highly aggressive children constituted 4.3% of the study population. Analysis showed significant influence of (a) gender: boys displayed higher levels of aggressiveness compared to girls; (b) dietary pattern: omnivores showed higher aggressiveness than vegetarians; and (c) school environment: boys in mixed-sex (coeducational) schools displayed lower aggressiveness than from single-sex schools. Statistically significant influences of religion (Hindu/Muslim) and family type (joint/nuclear) on aggressiveness profiles were not noticeable. Vegetarian diets and mixed-sex education act as protective factors in the development of aggressiveness in children, especially among boys. Extending investigations to populations differing in geography and cultural backgrounds are warranted to verify present results.
Di Marco, Aimee N; Jeyakumar, Jenifa; Pratt, Philip J; Yang, Guang-Zhong; Darzi, Ara W
2016-01-01
To compare surgical performance with transanal endoscopic surgery (TES) using a novel 3-dimensional (3D) stereoscopic viewer against the current modalities of a 3D stereoendoscope, 3D, and 2-dimensional (2D) high-definition monitors. TES is accepted as the primary treatment for selected rectal tumors. Current TES systems offer a 2D monitor, or 3D image, viewed directly via a stereoendoscope, necessitating an uncomfortable operating position. To address this and provide a platform for future image augmentation, a 3D stereoscopic display was created. Forty participants, of mixed experience level, completed a simulated TES task using 4 visual displays (novel stereoscopic viewer and currently utilized stereoendoscope, 3D, and 2D high-definition monitors) in a randomly allocated order. Primary outcome measures were: time taken, path length, and accuracy. Secondary outcomes were: task workload and participant questionnaire results. Median time taken and path length were significantly shorter for the novel viewer versus 2D and 3D, and not significantly different to the traditional stereoendoscope. Significant differences were found in accuracy, task workload, and questionnaire assessment in favor of the novel viewer, as compared to all 3 modalities. This novel 3D stereoscopic viewer allows surgical performance in TES equivalent to that achieved using the current stereoendoscope and superior to standard 2D and 3D displays, but with lower physical and mental demands for the surgeon. Participants expressed a preference for this system, ranking it more highly on a questionnaire. Clinical translation of this work has begun with the novel viewer being used in 5 TES patients.
Cholesteric Liquid Crystal Based Reflex Color Reflective Displays
NASA Astrophysics Data System (ADS)
Khan, Asad
2012-02-01
Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer products and related markets. This is a development that spans a wide space of highly technical development and fundamental science to products and commercialization to enable the entry of the technology into consumer markets.
Recent advances and product enhancements in reflective cholesteric displays
NASA Astrophysics Data System (ADS)
Khan, Asad; Schneider, Tod; Miller, Nick; Marhefka, Duane; Ernst, Todd; Nicholson, Forrest; Doane, Joseph W.
2005-04-01
Bistable reflective cholesteric displays are a liquid crystal display technology developed to fill a market need for very low power displays on a low-cost, high resolution passive matrix. Their unique look, high reflectivity, bistability, and simple structure make them an ideal flat panel display choice for handheld or other portable devices where small lightweight batteries with long lifetimes are important. We discuss recent advances in cholesteric display technology at Kent Displays such as progress towards single layer black and white displays, standard products, lower cost display modules, and various interface options for cholesteric display applications. It will be shown that inclusion of radio frequency (rf) control options and serial peripheral interface (spi) can greatly enhance the cholesteric display module market penetration by enabling quick integration into end devices. Finally, some discussion will be on the progress of the development of flexible reflective cholesteric displays. These flexible displays can dramatically change industrial design methods by enabling curved surfaces with displays integrated in them. Additional discussion in the paper will include applications of various display modes including signs, hand held instrumentation, and the electronic book and reader.
Effects of redundancy in the comparison of speech and pictorial displays in the cockpit environment.
Byblow, W D
1990-06-01
Synthesised speech and pictorial displays were compared in a spatially compatible simulated cockpit environment. Messages of high or low levels of redundancy were presented to subjects in both modality conditions. Subjects responded to warnings presented in a warning-only condition and in a dual-task condition, in which a simulated flight task was performed with visual and manual input/output modalities. Because the amount of information presented in most real-world applications and experimental paradigms is quantifiably large with respect to present guidelines for the use of synthesised speech warnings, the low-redundancy condition was hypothesised to allow for better performance. Results showed that subjects respond quicker to messages of low redundancy in both modalities. It is suggested that speech messages with low-redundancy levels were effective in minimising message length and ensuring that messages did not overload the short-term memory required to process and maintain speech in memory. Manipulation of phrase structure was used to optimise message redundancy and enhance the conceptual compatibility of the message without increasing message length or imposing a perceptual cost or memory overload. The results also suggest that system response times were quicker when synthesised speech warnings were used. This result is consistent with predictions from multiple resource theory which states that the resources required for the perception of verbal warnings are different from those for the flight task. It is also suggested that the perception of a pictorial display requires the same resources used for the perception of the primary flight task. An alternative explanation is that pictorial displays impose a visual scanning cost which is responsible for decreased performance. Based on the findings reported here, it is suggested that speech displays be incorporated in a spatially compatible cockpit environment because they allow equal or better performance when compared with pictorial displays. More importantly, the amount of time that the operator must direct his vision away from information vital to the flight task is decreased.
High-brightness displays in integrated weapon sight systems
NASA Astrophysics Data System (ADS)
Edwards, Tim; Hogan, Tim
2014-06-01
In the past several years Kopin has demonstrated the ability to provide ultra-high brightness, low power display solutions in VGA, SVGA, SXGA and 2k x 2k display formats. This paper will review various approaches for integrating high brightness overlay displays with existing direct view rifle sights and augmenting their precision aiming and targeting capability. Examples of overlay display systems solutions will be presented and discussed. This paper will review significant capability enhancements that are possible when augmenting the real-world as seen through a rifle sight with other soldier system equipment including laser range finders, ballistic computers and sensor systems.
Evidence for retrovirus infections in green turtles Chelonia mydas from the Hawaiian islands
Casey, R.N.; Quackenbush, S.L.; Work, Thierry M.; Balazs, G.H.; Bowser, P.R.; Casey, J.W.
1997-01-01
Apparently normal Hawaiian green turtles Chelonia mydas and those displaying fibropapillomas were analyzed for infection by retroviruses. Strikingly, all samples were positive for polymerase enhanced reverse transcriptase (PERT) with levels high enough to quantitate by the conventional reverse transcriptase (RT) assay. However, samples of skin, even from asymptomatic turtles, were RT positive, although the levels of enzyme activity in healthy turtles hatched and raised in captivity were much lower than those observed in asymptomatic free-ranging turtles. Turtles with fibropapillomas displayed a broad range of reverse transcriptase activity. Skin and eye fibropapillomas and a heart tumor were further analyzed and shown to have reverse transcriptase activity that banded in a sucrose gradient at 1.17 g ml-1. The reverse transcriptase activity purified from the heart tumor displayed a temperature optimum of 37??C and showed a preference for Mn2+ over Mg2+. Sucrose gradient fractions of this sample displaying elevated reverse transcriptase activity contained primarily retrovitalsized particles with prominent envelope spikes, when negatively stained and examined by electron microscopy. Sodium dodecylsulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analysis of gradient-purified virions revealed a conserved profile among 4 independent tumors and showed 7 prominent proteins having molecular weights of 116, 83, 51, 43, 40, 20 and 14 kDa. The data suggest that retroviral infections are widespread in Hawaiian green turtles and a comprehensive investigation is warranted to address the possibility that these agents cause green turtle fibropapillomatosis (GTFP).
Yeast Surface-Displayed H5N1 Avian Influenza Vaccines
Lei, Han; Jin, Sha; Karlsson, Erik; Schultz-Cherry, Stacey
2016-01-01
Highly pathogenic H5N1 avian influenza viruses pose a pandemic threat to human health. A rapid vaccine production against fast outbreak is desired. We report, herein, a paradigm-shift influenza vaccine technology by presenting H5N1 hemagglutinin (HA) to the surface of yeast. We demonstrated, for the first time, that the HA surface-presented yeast can be used as influenza vaccines to elicit both humoral and cell-mediated immunity in mice. The HI titer of antisera reached up to 128 in vaccinated mice. A high level of H5N1 HA-specific IgG1 and IgG2a antibody production was detected after boost immunization. Furthermore, we demonstrated that the yeast surface-displayed HA preserves its antigenic sites. It preferentially binds to both avian- and human-type receptors. In addition, the vaccine exhibited high cross-reactivity to both homologous and heterologous H5N1 viruses. A high level production of anti-HA antibodies was detected in the mice five months after vaccination. Finally, our animal experimental results indicated that the yeast vaccine offered complete protection of mice from lethal H5N1 virus challenge. No severe side effect of yeast vaccines was noted in animal studies. This new technology allows for rapid and large-scale production of influenza vaccines for prepandemic preparation. PMID:28078309
Janosik, Elzbieta; Grzesik, Jan
2003-01-01
The aim of this work was to evaluate the influence of different lighting levels at workstations with video display terminals (VDTs) on the course of the operators' visual work, and to determine the optimal levels of lighting at VDT workstations. For two kinds of job (entry of figures from a typescript and edition of the text displayed on the screen), the work capacity, the degree of the visual strain and the operators' subjective symptoms were determined for four lighting levels (200, 300, 500 and 750 lx). It was found that the work at VDT workstations may overload the visual system and cause eyes complaints as well as the reduction of accommodation or convergence strength. It was also noted that the edition of the text displayed on the screen is more burdening for operators than the entry of figures from a typescript. Moreover, the examination results showed that the lighting at VDT workstations should be higher than 200 lx and that 300 lx makes the work conditions most comfortable during the entry of figures from a typescript, and 500 lx during the edition of the text displayed on the screen.
Papakonstantinou, Nikos; Ntoufa, Stavroula; Chartomatsidou, Elisavet; Kotta, Konstantia; Agathangelidis, Andreas; Giassafaki, Lefki; Karamanli, Tzeni; Bele, Panagiota; Moysiadis, Theodoros; Baliakas, Panagiotis; Sutton, Lesley Ann; Stavroyianni, Niki; Anagnostopoulos, Achilles; Makris, Antonios M; Ghia, Paolo; Rosenquist, Richard; Stamatopoulos, Kostas
2016-06-14
The histone methyltransferase EZH2 induces gene repression through trimethylation of histone H3 at lysine 27 (H3K27me3). EZH2 overexpression has been reported in many types of cancer and associated with poor prognosis. Here we investigated the expression and functionality of EZH2 in chronic lymphocytic leukemia (CLL). Aggressive cases with unmutated IGHV genes (U-CLL) displayed significantly higher EZH2 expression compared to indolent CLL cases with mutated IGHV genes (M-CLL); furthermore, in U-CLL EZH2 expression was upregulated with disease progression. Within U-CLL, EZH2high cases harbored significantly fewer (p = 0.033) TP53 gene abnormalities compared to EZH2low cases. EZH2high cases displayed high H3K27me3 levels and increased viability suggesting that EZH2 is functional and likely confers a survival advantage to CLL cells. This argument was further supported by siRNA-mediated downmodulation of EZH2 which resulted in increased apoptosis. Notably, at the intraclonal level, cell proliferation was significantly associated with EZH2 expression. Treatment of primary CLL cells with EZH2 inhibitors induced downregulation of H3K27me3 levels leading to increased cell apoptosis. In conclusion, EZH2 is overexpressed in adverse-prognosis CLL and associated with increased cell survival and proliferation. Pharmacologic inhibition of EZH2 catalytic activity promotes apoptosis, highlighting EZH2 as a novel potential therapeutic target for specific subgroups of patients with CLL.
Chartomatsidou, Elisavet; Kotta, Konstantia; Agathangelidis, Andreas; Giassafaki, Lefki; Karamanli, Tzeni; Bele, Panagiota; Moysiadis, Theodoros; Baliakas, Panagiotis; Sutton, Lesley Ann; Stavroyianni, Niki; Anagnostopoulos, Achilles; Makris, Antonios M.; Ghia, Paolo; Rosenquist, Richard; Stamatopoulos, Kostas
2016-01-01
The histone methyltransferase EZH2 induces gene repression through trimethylation of histone H3 at lysine 27 (H3K27me3). EZH2 overexpression has been reported in many types of cancer and associated with poor prognosis. Here we investigated the expression and functionality of EZH2 in chronic lymphocytic leukemia (CLL). Aggressive cases with unmutated IGHV genes (U-CLL) displayed significantly higher EZH2 expression compared to indolent CLL cases with mutated IGHV genes (M-CLL); furthermore, in U-CLL EZH2 expression was upregulated with disease progression. Within U-CLL, EZH2high cases harbored significantly fewer (p = 0.033) TP53 gene abnormalities compared to EZH2low cases. EZH2high cases displayed high H3K27me3 levels and increased viability suggesting that EZH2 is functional and likely confers a survival advantage to CLL cells. This argument was further supported by siRNA-mediated downmodulation of EZH2 which resulted in increased apoptosis. Notably, at the intraclonal level, cell proliferation was significantly associated with EZH2 expression. Treatment of primary CLL cells with EZH2 inhibitors induced downregulation of H3K27me3 levels leading to increased cell apoptosis. In conclusion, EZH2 is overexpressed in adverse-prognosis CLL and associated with increased cell survival and proliferation. Pharmacologic inhibition of EZH2 catalytic activity promotes apoptosis, highlighting EZH2 as a novel potential therapeutic target for specific subgroups of patients with CLL. PMID:27191993
Mechanisms of time-based figure-ground segregation.
Kandil, Farid I; Fahle, Manfred
2003-11-01
Figure-ground segregation can rely on purely temporal information, that is, on short temporal delays between positional changes of elements in figure and ground (Kandil, F.I. & Fahle, M. (2001) Eur. J. Neurosci., 13, 2004-2008). Here, we investigate the underlying mechanisms by measuring temporal segregation thresholds for various kinds of motion cues. Segregation can rely on monocular first-order motion (based on luminance modulation) and second-order motion cues (contrast modulation) with a high temporal resolution of approximately 20 ms. The mechanism can also use isoluminant motion with a reduced temporal resolution of 60 ms. Figure-ground segregation can be achieved even at presentation frequencies too high for human subjects to inspect successive frames individually. In contrast, when stimuli are presented dichoptically, i.e. separately to both eyes, subjects are unable to perceive any segregation, irrespective of temporal frequency. We propose that segregation in these displays is detected by a mechanism consisting of at least two stages. On the first level, standard motion or flicker detectors signal local positional changes (flips). On the second level, a segregation mechanism combines the local activities of the low-level detectors with high temporal precision. Our findings suggest that the segregation mechanism can rely on monocular detectors but not on binocular mechanisms. Moreover, the results oppose the idea that segregation in these displays is achieved by motion detectors of a higher order (motion-from-motion), but favour mechanisms sensitive to short temporal delays even without activation of higher-order motion detectors.
Exposure-specific lung cancer risks in Chinese chrysotile textile workers and mining workers.
Wang, Xiaorong; Lin, Sihao; Yano, Eiji; Yu, Ignatius T S; Courtice, Midori; Lan, Yajia; Christiani, David C
2014-08-01
Whether there is a difference in the exposure-response slope for lung cancer between mining workers and textile workers exposed to chrysotile has not been well documented. This study was carried out to evaluate exposure-specific lung cancer risks in Chinese chrysotile textile workers and mining workers. A chrysotile mining worker cohort and a chrysotile textile worker cohort were observed concurrently for 26 years. Information on workers' vital status, occupational history and smoking habits were collected, and causes and dates of deaths were verified from death registries. Individual cumulative fiber exposures were estimated based on periodic dust/fiber measurements from different workshops, job title and duration, and categorized into four levels (Q1-Q4). Standardized mortality ratios (SMRs) for lung cancer were calculated and stratified by industry and job title with reference of the national rates. Cox proportional hazard models were fit to estimate the exposure-specific lung cancer risks upon adjustment for age and smoking, in which an external control cohort consisting of industrial workers without asbestos exposure was used as reference group for both textile and mining workers. SMRs were almost consistent with exposure levels in terms of job titles and workshops. A clear exposure-response relationship between lung cancer mortality and exposure levels was observed in both cohorts. At low exposure levels (Q1 and Q2), textile workers displayed higher death risks of lung cancer than mining workers. However, similarly considerably high risks were observed at higher exposure levels, with hazard ratios of over 8 and 11 at Q3 and Q4, respectively, for both textile and mining workers, after both age and smoking were adjusted. The chrysotile textile workers appeared to have a higher risk of lung cancer than the mining workers at a relatively low exposure level, but no difference was observed at a high exposure level, where both cohorts displayed a considerably high risk. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Natural Resource Information System. Volume 1: Overall description
NASA Technical Reports Server (NTRS)
1972-01-01
A prototype computer-based Natural Resource Information System was designed which could store, process, and display data of maximum usefulness to land management decision making. The system includes graphic input and display, the use of remote sensing as a data source, and it is useful at multiple management levels. A survey established current decision making processes and functions, information requirements, and data collection and processing procedures. The applications of remote sensing data and processing requirements were established. Processing software was constructed and a data base established using high-altitude imagery and map coverage of selected areas of SE Arizona. Finally a demonstration of system processing functions was conducted utilizing material from the data base.
Three-dimensional scene encryption and display based on computer-generated holograms.
Kong, Dezhao; Cao, Liangcai; Jin, Guofan; Javidi, Bahram
2016-10-10
An optical encryption and display method for a three-dimensional (3D) scene is proposed based on computer-generated holograms (CGHs) using a single phase-only spatial light modulator. The 3D scene is encoded as one complex Fourier CGH. The Fourier CGH is then decomposed into two phase-only CGHs with random distributions by the vector stochastic decomposition algorithm. Two CGHs are interleaved as one final phase-only CGH for optical encryption and reconstruction. The proposed method can support high-level nonlinear optical 3D scene security and complex amplitude modulation of the optical field. The exclusive phase key offers strong resistances of decryption attacks. Experimental results demonstrate the validity of the novel method.
Digital video system for on-line portal verification
NASA Astrophysics Data System (ADS)
Leszczynski, Konrad W.; Shalev, Shlomo; Cosby, N. Scott
1990-07-01
A digital system has been developed for on-line acquisition, processing and display of portal images during radiation therapy treatment. A metal/phosphor screen combination is the primary detector, where the conversion from high-energy photons to visible light takes place. A mirror angled at 45 degrees reflects the primary image to a low-light-level camera, which is removed from the direct radiation beam. The image registered by the camera is digitized, processed and displayed on a CRT monitor. Advanced digital techniques for processing of on-line images have been developed and implemented to enhance image contrast and suppress the noise. Some elements of automated radiotherapy treatment verification have been introduced.
NASA Astrophysics Data System (ADS)
Vassiliou, Marius S.; Sundareswaran, Venkataraman; Chen, S.; Behringer, Reinhold; Tam, Clement K.; Chan, M.; Bangayan, Phil T.; McGee, Joshua H.
2000-08-01
We describe new systems for improved integrated multimodal human-computer interaction and augmented reality for a diverse array of applications, including future advanced cockpits, tactical operations centers, and others. We have developed an integrated display system featuring: speech recognition of multiple concurrent users equipped with both standard air- coupled microphones and novel throat-coupled sensors (developed at Army Research Labs for increased noise immunity); lip reading for improving speech recognition accuracy in noisy environments, three-dimensional spatialized audio for improved display of warnings, alerts, and other information; wireless, coordinated handheld-PC control of a large display; real-time display of data and inferences from wireless integrated networked sensors with on-board signal processing and discrimination; gesture control with disambiguated point-and-speak capability; head- and eye- tracking coupled with speech recognition for 'look-and-speak' interaction; and integrated tetherless augmented reality on a wearable computer. The various interaction modalities (speech recognition, 3D audio, eyetracking, etc.) are implemented a 'modality servers' in an Internet-based client-server architecture. Each modality server encapsulates and exposes commercial and research software packages, presenting a socket network interface that is abstracted to a high-level interface, minimizing both vendor dependencies and required changes on the client side as the server's technology improves.
Laboratory and in-flight experiments to evaluate 3-D audio display technology
NASA Technical Reports Server (NTRS)
Ericson, Mark; Mckinley, Richard; Kibbe, Marion; Francis, Daniel
1994-01-01
Laboratory and in-flight experiments were conducted to evaluate 3-D audio display technology for cockpit applications. A 3-D audio display generator was developed which digitally encodes naturally occurring direction information onto any audio signal and presents the binaural sound over headphones. The acoustic image is stabilized for head movement by use of an electromagnetic head-tracking device. In the laboratory, a 3-D audio display generator was used to spatially separate competing speech messages to improve the intelligibility of each message. Up to a 25 percent improvement in intelligibility was measured for spatially separated speech at high ambient noise levels (115 dB SPL). During the in-flight experiments, pilots reported that spatial separation of speech communications provided a noticeable improvement in intelligibility. The use of 3-D audio for target acquisition was also investigated. In the laboratory, 3-D audio enabled the acquisition of visual targets in about two seconds average response time at 17 degrees accuracy. During the in-flight experiments, pilots correctly identified ground targets 50, 75, and 100 percent of the time at separation angles of 12, 20, and 35 degrees, respectively. In general, pilot performance in the field with the 3-D audio display generator was as expected, based on data from laboratory experiments.
Sense of presence and anxiety during virtual social interactions between a human and virtual humans.
Morina, Nexhmedin; Brinkman, Willem-Paul; Hartanto, Dwi; Emmelkamp, Paul M G
2014-01-01
Virtual reality exposure therapy (VRET) has been shown to be effective in treatment of anxiety disorders. Yet, there is lack of research on the extent to which interaction between the individual and virtual humans can be successfully implanted to increase levels of anxiety for therapeutic purposes. This proof-of-concept pilot study aimed at examining levels of the sense of presence and anxiety during exposure to virtual environments involving social interaction with virtual humans and using different virtual reality displays. A non-clinical sample of 38 participants was randomly assigned to either a head-mounted display (HMD) with motion tracker and sterescopic view condition or a one-screen projection-based virtual reality display condition. Participants in both conditions engaged in free speech dialogues with virtual humans controlled by research assistants. It was hypothesized that exposure to virtual social interactions will elicit moderate levels of sense of presence and anxiety in both groups. Further it was expected that participants in the HMD condition will report higher scores of sense of presence and anxiety than participants in the one-screen projection-based display condition. Results revealed that in both conditions virtual social interactions were associated with moderate levels of sense of presence and anxiety. Additionally, participants in the HMD condition reported significantly higher levels of presence than those in the one-screen projection-based display condition (p = .001). However, contrary to the expectations neither the average level of anxiety nor the highest level of anxiety during exposure to social virtual environments differed between the groups (p = .97 and p = .75, respectively). The findings suggest that virtual social interactions can be successfully applied in VRET to enhance sense of presence and anxiety. Furthermore, our results indicate that one-screen projection-based displays can successfully activate levels of anxiety in social virtual environments. The outcome can prove helpful in using low-cost projection-based virtual reality environments for treating individuals with social phobia.
The change in critical technologies for computational physics
NASA Technical Reports Server (NTRS)
Watson, Val
1990-01-01
It is noted that the types of technology required for computational physics are changing as the field matures. Emphasis has shifted from computer technology to algorithm technology and, finally, to visual analysis technology as areas of critical research for this field. High-performance graphical workstations tied to a supercommunicator with high-speed communications along with the development of especially tailored visualization software has enabled analysis of highly complex fluid-dynamics simulations. Particular reference is made here to the development of visual analysis tools at NASA's Numerical Aerodynamics Simulation Facility. The next technology which this field requires is one that would eliminate visual clutter by extracting key features of simulations of physics and technology in order to create displays that clearly portray these key features. Research in the tuning of visual displays to human cognitive abilities is proposed. The immediate transfer of technology to all levels of computers, specifically the inclusion of visualization primitives in basic software developments for all work stations and PCs, is recommended.
Lewinsohn, E; Ziv-Raz, I; Dudai, N; Tadmor, Y; Lastochkin, E; Larkov, O; Chaimovitsh, D; Ravid, U; Putievsky, E; Pichersky, E; Shoham, Y
2000-12-07
Sweet basil (Ocimum basilicum L., Lamiaceae) is a common herb, used for culinary and medicinal purposes. The essential oils of different sweet basil chemotypes contain various proportions of the allyl phenol derivatives estragole (methyl chavicol), eugenol, and methyl eugenol, as well as the monoterpene alcohol linalool. To monitor the developmental regulation of estragole biosynthesis in sweet basil, an enzymatic assay for S-adenosyl-L-methionine (SAM):chavicol O-methyltransferase activity was developed. Young leaves display high levels of chavicol O-methyltransferase activity, but the activity was negligible in older leaves, indicating that the O-methylation of chavicol primarily occurs early during leaf development. The O-methyltransferase activities detected in different sweet basil genotypes differed in their substrate specificities towards the methyl acceptor substrate. In the high-estragole-containing chemotype R3, the O-methyltransferase activity was highly specific for chavicol, while eugenol was virtually not O-methylated. In contrast, chemotype 147/97, that contains equal levels of estragole and methyl eugenol, displayed O-methyltransferase activities that accepted both chavicol and eugenol as substrates, generating estragole and methyl eugenol, respectively. Chemotype SW that contains high levels of eugenol, but lacks both estragole and methyl eugenol, had apparently no allylphenol dependent O-methyltransferase activities. These results indicate the presence of at least two types of allylphenol-specific O-methyltransferase activities in sweet basil chemotypes, one highly specific for chavicol; and a different one that can accept eugenol as a substrate. The relative availability and substrate specificities of these O-methyltransferase activities biochemically rationalizes the variation in the composition of the essential oils of these chemotypes.
NASA Astrophysics Data System (ADS)
Horii, Steven C.; Kundel, Harold L.; Shile, Peter E.; Carey, Bruce; Seshadri, Sridhar B.; Feingold, Eric R.
1994-05-01
As part of a study of the use of a PACS workstation compared to film in a Medical Intensive Care Unit, logs of workstation activity were maintained. The software for the workstation kept track of the type of user (i.e., intern, resident, fellow, or attending physician) and also of the workstation image manipulation functions used. The functions logged were: no operation, brightness/contrast adjustment, invert video, zoom, and high resolution display (this last function resulted in the display of the full 2 K X 2 K image rather than the usual subsampled 1 K X 1 K image. Associated data collection allows us to obtain the diagnostic category of the examination being viewed (e.g., location of tubes and lines, rule out: pneumonia, congestive heart failure, pneumothorax, and pleural effusion). The diagnostic categories and user type were then correlated with the use of workstation functions during viewing of images. In general, there was an inverse relationship between the level of training and the number of workstation uses. About two-thirds of the time, there was no image manipulation operation performed. Adjustment of brightness/contrast had the highest percentage of use overall, followed by zoom, video invert, and high resolution display.
The use of optical waveguides in head up display (HUD) applications
NASA Astrophysics Data System (ADS)
Homan, Malcolm
2013-06-01
The application of optical waveguides to Head Up Displays (HUD) is an enabling technology which solves the critical issues of volume reduction (including cockpit intrusion) and mass reduction in an affordable product which retains the high performance optical capabilities associated with today's generation of digital display based HUDs. Improved operability and pilot comfort is achieved regardless of the installation by virtue of the intrinsic properties of optical waveguides and this has enabled BAE Systems Electronic Systems to develop two distinct product streams for glareshield and overhead HUD installations respectively. This paper addresses the design drivers behind the development of the next generation of Head Up Displays and their compatibility with evolving cockpit architectures and structures. The implementation of large scale optical waveguide combiners capable of matching and exceeding the display performances normally only associated with current digital display sourced HUDs has enabled BAE Systems Electronic Systems to solve the volume and installation challenges of the latest military and civil cockpits with it's LiteHUD® technology. Glareshield mounted waveguide based HUDs are compatible with the trend towards the addition of Large Area Displays (LAD) in place of the traditional multiple Head Down Displays (HDD) within military fast jet cockpits. They use an "indirect view" variant of the display which allows the amalgamation of high resolution digital display devices with the inherently small volume and low mass of the waveguide optics. This is then viewed using the more traditional technology of a conventional HUD combiner. This successful combination of technologies has resulted in the LPHUD product which is specifically designed by BAE Systems Electronic Systems to provide an ultra-low profile HUD which can be installed behind a LAD; still providing the level of performance that is at least equivalent to that of a conventional large volume glareshield mounted HUD. In many current Business Jet and Air Transport cockpits overhead mounted HUDs employ a conventional optical combiner to relay the display from a separate projector to the pilot's eyes. In BAE Systems' Electronic Systems QHUDTM configuration this combiner is replaced by the waveguide and the bulky, intrusive overhead projector completely eliminated. The result is a significant reduction in equipment volume and mass and a much greater head clearance combined with a substantially larger Head Motion Box. This latter feature is a fundamental outturn of waveguide optical solutions which removes the restrictions on pilot eye positioning associated with current conventional systems. LiteHUD®, developed by BAE Systems, Electronic Systems achieves equivalent optical performance to in-service HUDs for less cost, mass and volume.
NASA Technical Reports Server (NTRS)
Clark, T. E.; Salazr, G. A; Brainard, G. C.
2016-01-01
The goal of this investigation is to determine design limitations and architectural solutions that limit the impact light from displays and indicator lamps have on the operational environment task lighting and lighting countermeasure spectrum constraints. It is concerning that this innovative architectural lighting system, could be compromised by spectrums from display systems, architectural materials, and structures that are not considered as part a full system design implementation. The introduction of many Commercial Off the Shelf (COTS) products to the spacecraft volume that contain LEDs, without consideration to the human factors and biological constraints, is another problem. Displays and indicators are a necessary part of the spacecraft and it is the goal of this research project to determine constraints and solutions that allow these systems to be integrated while minimizing how the lighting environment is modified by them. Due to the potentially broad scope of this endeavor, the project team developed constraints for the evaluation. The evaluation will be on a set of tasks that required significant exposure in the same environment while having a large chance of impacting the light spectrum the crew is expected to receive from the architectural lighting system. The team plans to use recent HRP research on "Net Habitable Volume" [1] to provide the boundary conditions for volume size. A Zemax ® lighting model was developed of a small enclosure that had high intensity overhead lighting and a standard intensity display with LED indicator arrays. The computer model demonstrated a work surface illuminated at a high level by the overhead light source compared to displays and indicators whose light is parallel to the work plane. The overhead lighting oversaturated spectral contributions from the display and indicator at the task work surface. Interestingly, when the observer looked at the displays and LEDs within the small enclosure, their spectral contribution was significant but could be reduced by reflecting overhead light from the wall(s) to the observer. Direct observation of displays and LEDs are an issue because the user's viewing area is a display, not an illuminated work surface. Since avionics command centers consume significant crew time, the tasks that seemed at higher risk for unwanted spectral contributions as an operational volume with significant quantity of displays and indicators that were either under direct observation of the crew or impacting a volume the crew may be required to sleep in.
Raster Scan Computer Image Generation (CIG) System Based On Refresh Memory
NASA Astrophysics Data System (ADS)
Dichter, W.; Doris, K.; Conkling, C.
1982-06-01
A full color, Computer Image Generation (CIG) raster visual system has been developed which provides a high level of training sophistication by utilizing advanced semiconductor technology and innovative hardware and firmware techniques. Double buffered refresh memory and efficient algorithms eliminate the problem of conventional raster line ordering by allowing the generated image to be stored in a random fashion. Modular design techniques and simplified architecture provide significant advantages in reduced system cost, standardization of parts, and high reliability. The major system components are a general purpose computer to perform interfacing and data base functions; a geometric processor to define the instantaneous scene image; a display generator to convert the image to a video signal; an illumination control unit which provides final image processing; and a CRT monitor for display of the completed image. Additional optional enhancements include texture generators, increased edge and occultation capability, curved surface shading, and data base extensions.
Visualizing Sound: Demonstrations to Teach Acoustic Concepts
NASA Astrophysics Data System (ADS)
Rennoll, Valerie
Interference, a phenomenon in which two sound waves superpose to form a resultant wave of greater or lower amplitude, is a key concept when learning about the physics of sound waves. Typical interference demonstrations involve students listening for changes in sound level as they move throughout a room. Here, new tools are developed to teach this concept that provide a visual component, allowing individuals to see changes in sound level on a light display. This is accomplished using a microcontroller that analyzes sound levels collected by a microphone and displays the sound level in real-time on an LED strip. The light display is placed on a sliding rail between two speakers to show the interference occurring between two sound waves. When a long-exposure photograph is taken of the light display being slid from one end of the rail to the other, a wave of the interference pattern can be captured. By providing a visual component, these tools will help students and the general public to better understand interference, a key concept in acoustics.
Departure from the onset-onset rule.
Chow, S L
1994-09-01
Using a signal-detection task, the generality of Turvey's (1973) onset-onset rule was tested in our experiments. After seeing, in succession, (1) one or two letters (target display), (2) a multiletter detection display, and (3) a mask display, subjects decided whether or not the letter or letters in the target display reappeared in the succeeding detection display at different levels of detection-display duration in various situations. The subjects' sensitivity was inconsistent with the onset-onset rule. More specifically, sensitivity increased with increases in display duration within a fixed stimulus onset asynchrony of 150 msec. Display duration, however, had no effect on response bias. Nor was there any interaction between display duration and display size in terms of either sensitivity or response bias. The more complicated relationship between display duration and display size does not invalidate the departure from the onset-onset rule.
NASA Astrophysics Data System (ADS)
Drzaic, Paul S.; Wiley, Richard C.; McCoy, James A.
1989-07-01
A new class of high-brightness, high color contrast reflective-mode displays can be constructed from nematic droplet/polymer (NCAP) films. In these films, a high order parameter pleochroic dye can be dissolved in the nematic, leading to a film with both controllable absorbance and scattering. The physics behind the operation of these films is discussed. The intrinsic optical order parameter of a guest-host mixture is related to the performance of the NCAP film. It is shown that the scattering effects inherent in these films can be used to amplify the effects of the controllable dye absorbance, leading to excellent optical performance for a reflective-mode display. A typical construction of a display cell is given, and examples of applications are discussed. Touch switches may easily be fabricated within the display, so that an integrated control/display module can be constructed.
Measuring causal perception: connections to representational momentum?
Choi, Hoon; Scholl, Brian J
2006-01-01
In a collision between two objects, we can perceive not only low-level properties, such as color and motion, but also the seemingly high-level property of causality. It has proven difficult, however, to measure causal perception in a quantitatively rigorous way which goes beyond perceptual reports. Here we focus on the possibility of measuring perceived causality using the phenomenon of representational momentum (RM). Recent studies suggest a relationship between causal perception and RM, based on the fact that RM appears to be attenuated for causally 'launched' objects. This is explained by appeal to the visual expectation that a 'launched' object is inert and thus should eventually cease its movement after a collision, without a source of self-propulsion. We first replicated these demonstrations, and then evaluated this alleged connection by exploring RM for different types of displays, including the contrast between causal launching and non-causal 'passing'. These experiments suggest that the RM-attenuation effect is not a pure measure of causal perception, but rather may reflect lower-level spatiotemporal correlates of only some causal displays. We conclude by discussing the strengths and pitfalls of various methods of measuring causal perception.
Garland, Ellen C; Rendell, Luke; Lilley, Matthew S; Poole, M Michael; Allen, Jenny; Noad, Michael J
2017-07-01
Identifying and quantifying variation in vocalizations is fundamental to advancing our understanding of processes such as speciation, sexual selection, and cultural evolution. The song of the humpback whale (Megaptera novaeangliae) presents an extreme example of complexity and cultural evolution. It is a long, hierarchically structured vocal display that undergoes constant evolutionary change. Obtaining robust metrics to quantify song variation at multiple scales (from a sound through to population variation across the seascape) is a substantial challenge. Here, the authors present a method to quantify song similarity at multiple levels within the hierarchy. To incorporate the complexity of these multiple levels, the calculation of similarity is weighted by measurements of sound units (lower levels within the display) to bridge the gap in information between upper and lower levels. Results demonstrate that the inclusion of weighting provides a more realistic and robust representation of song similarity at multiple levels within the display. This method permits robust quantification of cultural patterns and processes that will also contribute to the conservation management of endangered humpback whale populations, and is applicable to any hierarchically structured signal sequence.
Atrazine Resistance in Chenopodium album
Bettini, Priscilla; McNally, Sheila; Sevignac, Mireille; Darmency, Henri; Gasquez, Jacques; Dron, Michel
1987-01-01
In Chenopodium album two different levels of atrazine resistance have been found according to following criteria: lethal dose and leaf fluorescence curve. The intermediate (I) phenotype is represented by a low level of resistance and a typical I fluorescence curve. It arose at high frequency, within one generation, after self-pollination of particular plants displaying a susceptible (S) phenotype. The resistance phenotype (Ri) has a high level of resistance and presents a typical resistant fluorescence curve. It appeared after self-pollination of chemically treated I plants. The I, Ri, and also R (resistant plants found in atrazine treated fields) phenotypes contain a serine to glycine mutation at amino acid position 264 in the chloroplast psbA gene product. The steady state level of the psbA gene transcript is not modified between S, I, Ri, and R phenotypes. Images Fig. 4 PMID:16665624
Sumners, L H; Cox, C M; Kim, S; Salevsky, J E; Siegel, P B; Dalloul, R A
2012-03-01
Chickens genetically selected for low (LA) or high (HA) antibody response to SRBC displayed a correlated change in MHC, so that LA chickens were 96% B13 and HA chickens were 96% B21. The LA line appears to be less susceptible to invasion by extracellular pathogens, whereas HA chickens are more resistant to infection by intracellular organisms. Resistance to Clostridium perfringens is one instance in which the lines do not follow their established trend of pathogen susceptibility, where during a clinical outbreak of necrotic enteritis, B21B21 genotypes experienced significantly less mortality than B13B13 genotypes. A study was carried out to assess immunological differences between LA and HA lines during exposure to C. perfringens α-toxin. Peripheral blood mononuclear cells were isolated from each genetic line, cultured with or without lipopolysaccharide (4 h), and exposed to varying concentrations of α-toxin (1; 10; 100; and 1,000 U/L) for 2 and 4 h. Evaluation of cellular proliferation, percentage of cytotoxicity, and immunological gene expression was carried out in a series of experiments. Cells isolated from HA chickens had significantly increased proliferation than those from LA chickens at low toxin levels (1 and 10 U/L) and significantly decreased proliferation at high toxin levels (100 and 1,000 U/L). Following exposure to lipopolysaccharide, the percentage of cytotoxicity was higher for LA than HA cells. In both assays, HA cells displayed superior performance following lipopolysaccharide-stimulation. Gene expression analysis of immune transcripts by quantitative real-time PCR revealed significantly upregulated expression of interferon (IFN)-γ, interleukin (IL)-8, IL-13 (2 h), IL-15, and CXCLi1 (4 h) in HA than LA chickens. Cells isolated from the LA line displayed significantly elevated expression of IL-2, IL-10, IL-13 (4 h), IL-16, IL-18, inducible nitric oxide synthase (iNOS), CXCLi1 (2 h), and lipopolysaccharide-induced tumor necrosis factor-α factor (LITAF) compared with the HA line. Clearly, these 2 genetic lines display highly divergent immune responses in regards to C. perfringens toxin exposure.
A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen
NASA Astrophysics Data System (ADS)
Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu
2018-02-01
Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.
A large flat panel multifunction display for military and space applications
NASA Astrophysics Data System (ADS)
Pruitt, James S.
1992-09-01
A flat panel multifunction display (MFD) that offers the size and reliability benefits of liquid crystal display technology while achieving near-CRT display quality is presented. Display generation algorithms that provide exceptional display quality are being implemented in custom VLSI components to minimize MFD size. A high-performance processor converts user-specified display lists to graphics commands used by these components, resulting in high-speed updates of two-dimensional and three-dimensional images. The MFD uses the MIL-STD-1553B data bus for compatibility with virtually all avionics systems. The MFD can generate displays directly from display lists received from the MIL-STD-1553B bus. Complex formats can be stored in the MFD and displayed using parameters from the data bus. The MFD also accepts direct video input and performs special processing on this input to enhance image quality.
Control/display trade-off study for single-pilot instrument flight rule operations
NASA Technical Reports Server (NTRS)
Hoh, R.
1983-01-01
The objectives were to determine minimum autopilot functions and displays required to keep pilot workload at an acceptable level; to determine what constitutes an acceptable level of workload; to identify critical tasks; and to suggest specific experiments required to refine conclusions. It was determined that workload relief is derived from basic stability augmentation; that complex autopilots can lead to serious blunders; and that displays need to enhance positional awareness and minimize the likelihood of false hypothesis.
Zheng, Hao; Wang, Xiong; Ren, Feifei; Zou, Shenglong; Feng, Min; Xu, Liangliang; Yao, Lunguang; Sun, Jingchen
2018-06-19
The classical baculovirus display system (BDS) has often recruited fields including gene delivery, gene therapy, and the genetic engineering of vaccines, as it is capable of presenting foreign polypeptides on the membranes of recombinant baculovirus through a transmembrane protein. However, classical BDS's high cost, complicated operation, low display efficiency and its inability to simultaneously display multiple gene products impede its practicality. In this study, we present a novel and highly efficient display system based on ires-dependent gp64 for rescuing gp64-null Bacmid of baculovirus construction without affecting the viral replication cycle, which we name the baculovirus multigene display system (BMDS). Laser scanning confocal microscopy demonstrated that eGFP, eYFP, and mCherry were translocated on the membrane of Spodoptera frugiperda 9 cell successfully as expected. Western blot analysis further confirmed the presence of the fluorescent proteins on the budded, mature viral particles. The results showed the display efficiency of target gene on cell surface is fourfold that of classical BDS. In addition, a recombinant baculovirus displaying three kinds of fluorescent proteins simultaneously was constructed, thereby demonstrating the effectiveness of BMDS as a co-display system.
Display challenges resulting from the use of wide field of view imaging devices
NASA Astrophysics Data System (ADS)
Petty, Gregory J.; Fulton, Jack; Nicholson, Gail; Seals, Ean
2012-06-01
As focal plane array technologies advance and imagers increase in resolution, display technology must outpace the imaging improvements in order to adequately represent the complete data collection. Typical display devices tend to have an aspect ratio similar to 4:3 or 16:9, however a breed of Wide Field of View (WFOV) imaging devices exist that skew from the norm with aspect ratios as high as 5:1. This particular quality, when coupled with a high spatial resolution, presents a unique challenge for display devices. Standard display devices must choose between resizing the image data to fit the display and displaying the image data in native resolution and truncating potentially important information. The problem compounds when considering the applications; WFOV high-situationalawareness imagers are sought for space-limited military vehicles. Tradeoffs between these issues are assessed to the image quality of the WFOV sensor.
Exploratory visualization of astronomical data on ultra-high-resolution wall displays
NASA Astrophysics Data System (ADS)
Pietriga, Emmanuel; del Campo, Fernando; Ibsen, Amanda; Primet, Romain; Appert, Caroline; Chapuis, Olivier; Hempel, Maren; Muñoz, Roberto; Eyheramendy, Susana; Jordan, Andres; Dole, Hervé
2016-07-01
Ultra-high-resolution wall displays feature a very high pixel density over a large physical surface, which makes them well-suited to the collaborative, exploratory visualization of large datasets. We introduce FITS-OW, an application designed for such wall displays, that enables astronomers to navigate in large collections of FITS images, query astronomical databases, and display detailed, complementary data and documents about multiple sources simultaneously. We describe how astronomers interact with their data using both the wall's touchsensitive surface and handheld devices. We also report on the technical challenges we addressed in terms of distributed graphics rendering and data sharing over the computer clusters that drive wall displays.
Movement compatibility for frontal controls with displays located in four cardinal orientations.
Chan, Alan H S; Hoffmann, Errol R
2010-12-01
Strength and reversibility of direction-of-motion stereotypes and response times are presented for different configurations of horizontal, vertical and rotary controls with horizontal, vertical and circular displays. Measures of the strength and reversibility of stereotypes were used to analyse the effects of direction of turn instruction (clockwise/anticlockwise; up/down; left/right), display orientation (North; East; South; West) and hand side (left/right) on movement compatibility. A number of acceptable display/control arrangements were identified for displays in each of the North, East, South and West orientations relative to the operator. For the horizontally moving control, the Worringham and Beringer principle was found to identify display/control arrangements having both high stereotype strength and high reversibility. Vertically moving controls are excellent with vertical displays but poor with horizontal and circular displays. Rotary controls have high stereotype strength and reversibility with both horizontal and circular displays (with the indicator at the 12 o'clock position). STATEMENT OF RELEVANCE: Design of display/control arrangements requires a strong relationship between operator's expectancies and the response of a device to control inputs. The present research fills in gaps for stereotypes where data are not available, in particular where the operator is not seated facing a display directly to the front.
Sandén, Emma; Enríquez Pérez, Julio; Visse, Edward; Kool, Marcel; Carén, Helena; Siesjö, Peter; Darabi, Anna
2016-12-01
Primary brain tumors are the most common solid tumors in children. Increasing evidence demonstrates diverse intratumoral immune signatures, which are tentatively reflected in peripheral blood. Twenty cytokines were analyzed in preoperative plasma samples from five healthy children and 45 children with brain tumors, using a multiplex platform (MesoScale Discovery V-PLEX ® ). Tumor types included medulloblastoma (MB), ependymoma, sarcoma, high-grade glioma, pilocytic astrocytoma, and other low-grade gliomas. A panel of four cytokines [VEGFA, interleukin (IL)-7, IL-17A, and tumor necrosis factor (TNF)-β] delineated two distinct patient groups, identified as VEGFA high IL-7 high IL-17A low TNF-β low (Group A) and VEGFA low IL-7 low IL-17A high TNF-β high (Group B). Healthy controls and the vast majority of patients with MB were found within Group A, whereas patients with other tumor types were equally distributed between the two groups. Unrelated to A/B affiliation, we detected trends toward increased IL-10 and decreased IL-12/23 and TNF-α in several tumor types. Finally, a small number of patients displayed evidence of enhanced systemic immune activation, including elevated levels of interferon-γ, granulocyte monocyte colony-stimulating factor, IL-6, IL-12/23, and TNF-α. Following tumor resection, cytokine levels in a MB patient approached the levels of healthy controls. We identify common features and individual differences in the systemic immune profiles of children with brain tumors. Overall, patients with MB displayed a uniform cytokine profile, whereas other tumor diagnoses did not predict systemic immunological status in single patients. Future characterization and monitoring of systemic immune responses in children with brain tumors will have important implications for the development and implementation of immunotherapy. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Wirth, M. N.
1975-01-01
Small, portable, self-contained device provides high-speed display of bit pattern or any selected portion of transmission, can suppress filler patterns so that display is not updated, and can freeze display so that specific event may be observed in detail.
Interpersonal Values and Academic Performance Related to Delinquent Behaviors
Molero Jurado, María Del Mar; Pérez Fuentes, María Del Carmen; Luque De La Rosa, Antonio; Martos Martínez, África; Barragán Martín, Ana Belén; Simón Márquez, María del Mar
2016-01-01
The present study analyzes the relation between delinquent behaviors, interpersonal values, and academic performance. It also analyzes the possible protective function of interpersonal values against delinquent behaviors. The Interpersonal Values Questionnaire (IVQ) was used to assess interpersonal values, and the Antisocial-Delinquent Behaviors Questionnaire (A-D) was employed to assess antisocial behaviors. The sample was made up of 885 students of Compulsory Secondary Education, aged from 14 to 17 years. The results show that individuals who fail a subject as well as those who repeat a course present higher means in delinquent behaviors. Repeaters present higher means in the values of recognition and leadership, and non-repeaters in the value stimulation, whereas students who do not fail obtain higher scores in the value benevolence. Students with high levels of recognition, independence, and leadership, as well as students with low levels of conformity and benevolence display significantly higher levels of delinquent behaviors. Lastly, the probability of presenting a high level of delinquent behaviors is greater in individuals with: high independence, high leadership, high recognition, low benevolence, and low conformity. PMID:27799914
Implicit Racial Biases in Preschool Children and Adults from Asia and Africa
ERIC Educational Resources Information Center
Qian, Miao K.; Heyman, Gail D.; Quinn, Paul C.; Messi, Francoise A.; Fu, Genyue; Lee, Kang
2016-01-01
This research used an Implicit Racial Bias Test to investigate implicit racial biases among 3- to 5-year-olds and adult participants in China (N = 213) and Cameroon (N = 257). In both cultures, participants displayed high levels of racial biases that remained stable between 3 and 5 years of age. Unlike adults, young children's implicit racial…
ERIC Educational Resources Information Center
Henman, Karen
2010-01-01
During the early grades, female students generally display enthusiasm for learning science. As these same students go though school, however, their level of motivation changes. Once female students reach high school, many lack the confidence to take chemistry and physics. Then, in college they lack the background necessary to major in chemistry,…
Todd E. Katzner; Daniel S. Jackson; Jamie Ivy; Evgeny A. Bragin; Andrew Dewoody
2014-01-01
Sex ratio theory attempts to explain observed variation in offspring sex ratio at both the population and the brood levels. In the context of low-fecundity organisms producing high-investment offspring, the drivers of adaptive variation in sex ratio are incompletely understood. For raptors that display reverse sexual dimorphism (RSD), preferential allocation of...
Orion-CEV Project Overview To the NASA Sports and Exploration "Kick-Off" Meeting
NASA Technical Reports Server (NTRS)
Marshall, Paul F.
2007-01-01
This viewgraph presentation reviews the Orion Crew Exploration vehicle (CEV) and its usage in the exploration of the moon and subsequent travel to Mars. Schedules for development and testing of the CEV are shown. Also displayed are various high level design views of the CEV, the launch abort system, the Atlas Docking adapter, and the service module.
ERIC Educational Resources Information Center
Bradshaw, Catherine P.; Schaeffer, Cindy M.; Petras, Hanno; Ialongo, Nicholas
2010-01-01
Transactional theories of development suggest that displaying high levels of antisocial behavior early in life and persistently over time causes disruption in multiple life domains, which in turn places individuals at risk for negative life outcomes. We used longitudinal data from 1,137 primarily African American urban youth (49.1% female) to…
Consortium for military LCD display procurement
NASA Astrophysics Data System (ADS)
Echols, Gregg
2002-08-01
International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.
A novel role of HLA class I in the pathology of medulloblastoma.
Smith, Courtney; Santi, Mariarita; Rajan, Bhargavi; Rushing, Elisabeth J; Choi, Mi Rim; Rood, Brian R; Cornelison, Robert; MacDonald, Tobey J; Vukmanovic, Stanislav
2009-07-12
MHC class I expression by cancer cells enables specific antigen recognition by the immune system and protection of the host. However, in some cancer types MHC class I expression is associated with an unfavorable outcome. We explored the basis of MHC class I association with unfavorable prognostic marker expression in the case of medulloblastoma. We investigated expression of four essential components of MHC class I (heavy chain, beta2m, TAP1 and TAP2) in 10 medulloblastoma mRNA samples, a tissue microarray containing 139 medulloblastoma tissues and 3 medulloblastoma cell lines. Further, in medulloblastoma cell lines we evaluated the effects of HLA class I engagement on activation of ERK1/2 and migration in vitro. The majority of specimens displayed undetectable or low levels of the heavy chains. Medulloblastomas expressing high levels of HLA class I displayed significantly higher levels of anaplasia and c-myc expression, markers of poor prognosis. Binding of beta2m or a specific antibody to open forms of HLA class I promoted phosphorylation of ERK1/2 in medulloblastoma cell line with high levels, but not in the cell line with low levels of HLA heavy chain. This treatment also promoted ERK1/2 activation dependent migration of medulloblastoma cells. MHC class I expression in medulloblastoma is associated with anaplasia and c-myc expression, markers of poor prognosis. Peptide- and/or beta2m-free forms of MHC class I may contribute to a more malignant phenotype of medulloblastoma by modulating activation of signaling molecules such as ERK1/2 that stimulates cell mobility.
A novel role of HLA class I in the pathology of medulloblastoma
Smith, Courtney; Santi, Mariarita; Rajan, Bhargavi; Rushing, Elisabeth J; Choi, Mi Rim; Rood, Brian R; Cornelison, Robert; MacDonald, Tobey J; Vukmanovic, Stanislav
2009-01-01
Background MHC class I expression by cancer cells enables specific antigen recognition by the immune system and protection of the host. However, in some cancer types MHC class I expression is associated with an unfavorable outcome. We explored the basis of MHC class I association with unfavorable prognostic marker expression in the case of medulloblastoma. Methods We investigated expression of four essential components of MHC class I (heavy chain, β2m, TAP1 and TAP2) in 10 medulloblastoma mRNA samples, a tissue microarray containing 139 medulloblastoma tissues and 3 medulloblastoma cell lines. Further, in medulloblastoma cell lines we evaluated the effects of HLA class I engagement on activation of ERK1/2 and migration in vitro. Results The majority of specimens displayed undetectable or low levels of the heavy chains. Medulloblastomas expressing high levels of HLA class I displayed significantly higher levels of anaplasia and c-myc expression, markers of poor prognosis. Binding of β2m or a specific antibody to open forms of HLA class I promoted phosphorylation of ERK1/2 in medulloblastoma cell line with high levels, but not in the cell line with low levels of HLA heavy chain. This treatment also promoted ERK1/2 activation dependent migration of medulloblastoma cells. Conclusion MHC class I expression in medulloblastoma is associated with anaplasia and c-myc expression, markers of poor prognosis. Peptide- and/or β2m-free forms of MHC class I may contribute to a more malignant phenotype of medulloblastoma by modulating activation of signaling molecules such as ERK1/2 that stimulates cell mobility. PMID:19594892
Lanctot, Richard B.; Sandercock, B.K.; Kempenaers, Bart
2000-01-01
Many shorebirds show elaborate breeding displays that include aerial flights and ground displays accompanied by song. The mate attraction hypothesis suggests that breeding displays function to attract mates and maintain pair bonds, whereas the territory defense hypothesis suggests breeding displays function in defining and defending nesting and feeding territories. We tested these hypotheses in the Western Sandpiper (Calidris mauri) by contrasting the duration and level of male breeding displays among pairs that differed in their mate and site fidelity. As predicted by the mate attraction hypothesis, males performed the highest number of song sequences during pair formation, and males paired with their mate of a prior year sang less than males paired to new mates. Further, sitefaithful males mated to a new but experienced mate displayed significantly more than remated males or males new to the area. This suggests a male's prior familiarity with an area and his neighbors does not lessen his display rate as was predicted under the territory defense hypothesis. Limited support for the territory defense hypothesis came from observations of males performing breeding displays with neighboring males along nest territory boundaries. This behavior was short-lived, however, as males abandoned nesting areas after pair-formation and used adjacent or disjointed feeding areas during egg-laying and incubation. Male aggression (i.e., aerial and ground chases), as opposed to breeding displays, appeared to be the principal means of maintaining territory boundaries. Indeed, the rate at which males chased other males remained fairly constant and high throughout the breeding season. Male chasing behavior may also serve as a paternity guard to protect against extra-pair copulations. Our study also found that a female's prior breeding experience in an area correlated with a reduced display rate by her mate, particularly if that mate was new to the area. This indicates female characteristics may not only drive nest initiation, as has been shown in other studies, but are important in determining the duration and extent of male display.
Løset, Geir Åge; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger
2011-01-01
Background Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Methodology/Principal Findings Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Conclusions/Significance Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before. PMID:21390283
2015-09-01
with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS . 1...UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS (ES) Technical and Project Engineering, LLC QED Systems, LLC Alexandria, VA...AND ADDRESS (ES) US Army Research Laboratory ATTN: RDRL-CIH-C Aberdeen Proving Ground, MD 21005 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR
Speeding in highway work zone: An Evaluation of methods of speed control.
Ravani, Bahram; Wang, Chao
2018-04-01
Highway workers frequently work in close proximity of live traffic in highway work zones, traffic accidents therefore have devastating effects on worker safety. In order to reduce the potential for such accidents, methods involving use of advisory signs and police presence have been used to mitigate accident risks and improve safety for highway workers. This research evaluates the magnitude of the speeding problem in highway work zones and the effects of four levels of police presence on improving work zone safety. Speed data were collected in six different work zone locations in northern and southern California and used to determine the magnitude and nature of speeding problem in highway work zones. In addition data were collected over 11 test-days in four work zones with four levels of police presence: radar speed display with police decal and lighting, passive use of a police vehicle with radar speed display, passive use of a police vehicle without radar speed display, and active police speed enforcement near work zones. This paper analyzes this data using statistical methods to evaluate the effectiveness of these different methods of speed control on the safety of the work zone. Four Measures of Effectiveness (MOE) were used in this evaluation consisting of average speed reduction, speed variance, 85th percentile speed, and proportion of high speed vehicles. The results indicate that all levels of police presence provided statistically significant improvements in one or more of the MOEs. Copyright © 2018 Elsevier Ltd. All rights reserved.
The effects of belongingness on the Simultaneous Lightness Contrast: a virtual reality study.
Soranzo, Alessandro; Lugrin, Jean-Luc; Wilson, Christopher J
2013-06-28
Simultaneous Lightness Contrast (SLC) is the phenomenon whereby a grey patch on a dark background appears lighter than an equal patch on a light background. Interestingly, the lightness difference between these patches undergoes substantial augmentation when the two backgrounds are patterned, thereby forming the articulated-SLC display. There are two main interpretations of these phenomena: The mid-level interpretation maintains that the visual system groups the luminance within a set of contiguous frameworks, whilst the high-level one claims that the visual system splits the luminance into separate overlapping layers corresponding to separate physical contributions. This research aimed to test these two interpretations by systematically manipulating the viewing distance and the horizontal distance between the backgrounds of both the articulated and plain SLC displays. An immersive 3D Virtual Reality system was employed to reproduce identical alignment and distances, as well as isolating participants from interfering luminance. Results showed that reducing the viewing distance resulted in increased contrast in both the plain- and articulated-SLC displays and that, increasing the horizontal distance between the backgrounds resulted in decreased contrast in the articulated condition but increased contrast in the plain condition. These results suggest that a comprehensive lightness theory should combine the two interpretations. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
3D brain MR angiography displayed by a multi-autostereoscopic screen
NASA Astrophysics Data System (ADS)
Magalhães, Daniel S. F.; Ribeiro, Fádua H.; Lima, Fabrício O.; Serra, Rolando L.; Moreno, Alfredo B.; Li, Li M.
2012-02-01
The magnetic resonance angiography (MRA) can be used to examine blood vessels in key areas of the body, including the brain. In the MRA, a powerful magnetic field, radio waves and a computer produce the detailed images. Physicians use the procedure in brain images mainly to detect atherosclerosis disease in the carotid artery of the neck, which may limit blood flow to the brain and cause a stroke and identify a small aneurysm or arteriovenous malformation inside the brain. Multi-autostereoscopic displays provide multiple views of the same scene, rather than just two, as in autostereoscopic systems. Each view is visible from a different range of positions in front of the display. This allows the viewer to move left-right in front of the display and see the correct view from any position. The use of 3D imaging in the medical field has proven to be a benefit to doctors when diagnosing patients. For different medical domains a stereoscopic display could be advantageous in terms of a better spatial understanding of anatomical structures, better perception of ambiguous anatomical structures, better performance of tasks that require high level of dexterity, increased learning performance, and improved communication with patients or between doctors. In this work we describe a multi-autostereoscopic system and how to produce 3D MRA images to be displayed with it. We show results of brain MR angiography images discussing, how a 3D visualization can help physicians to a better diagnosis.
NASA Astrophysics Data System (ADS)
Gruber, Thomas; Grim, Larry; Fauth, Ryan; Tercha, Brian; Powell, Chris; Steinhardt, Kristin
2011-05-01
Large networks of disparate chemical/biological (C/B) sensors, MET sensors, and intelligence, surveillance, and reconnaissance (ISR) sensors reporting to various command/display locations can lead to conflicting threat information, questions of alarm confidence, and a confused situational awareness. Sensor netting algorithms (SNA) are being developed to resolve these conflicts and to report high confidence consensus threat map data products on a common operating picture (COP) display. A data fusion algorithm design was completed in a Phase I SBIR effort and development continues in the Phase II SBIR effort. The initial implementation and testing of the algorithm has produced some performance results. The algorithm accepts point and/or standoff sensor data, and event detection data (e.g., the location of an explosion) from various ISR sensors (e.g., acoustic, infrared cameras, etc.). These input data are preprocessed to assign estimated uncertainty to each incoming piece of data. The data are then sent to a weighted tomography process to obtain a consensus threat map, including estimated threat concentration level uncertainty. The threat map is then tested for consistency and the overall confidence for the map result is estimated. The map and confidence results are displayed on a COP. The benefits of a modular implementation of the algorithm and comparisons of fused / un-fused data results will be presented. The metrics for judging the sensor-netting algorithm performance are warning time, threat map accuracy (as compared to ground truth), false alarm rate, and false alarm rate v. reported threat confidence level.
Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samei, Ehsan; Badano, Aldo; Chakraborty, Dev
Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction withmore » specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L{sub amb}) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m{sup 2}, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u{sup '},v{sup '} color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.« less
Culturally Responsive Physics Teaching: Content or Conveyance?
NASA Astrophysics Data System (ADS)
Stewart, Taquan Seth
2011-12-01
This study, in response to the achievement gap in science and the lack of significant numbers of ethnic minorities in science fields, examined the effects of a Cultural Responsiveness Workshop and intervention on teacher practice, teacher discourse, and student perceptions and connectedness to physics. The sample was comprised of three high school physics teachers---2 teaching five 12th grade sections and one teaching five 9th grade sections of physics---in two separate urban schools in the same section of South Los Angeles. My research design was qualitative and examined eight culturally responsive indicators that, when applied, may increase student engagement and level of connectedness in urban high school physics classrooms: (1) proximity to students, (2) the ways in which they encouraged students, (3) positive reinforcement techniques, (4) modifications for individual learning types, (5) use of children's strengths, (6) scaffolding, (7) displaying an understanding of diverse cultures, and (8) displaying a personal regard for students of diverse cultures. When the study was completed and data was collected, I identified trends in the change in teacher discourse, behaviors, instructional practice, and perceptions of student engagement. My findings, discovered through classroom observations and focus groups, indicated a positive shift in each. Accompanying these shifts were positive shifts in level of student engagement and level of connectedness. There were also the unexpected findings of the need for teachers to receive feedback in a safe collaborative space and the use of culturally responsive teaching as a tool for behavioral management. My study found that there is a definite relationship between the use of the culturally responsive indicators observed, student engagement and student level of connectedness to physics when implemented in urban high school science classrooms.
Fiber-optic three axis magnetometer prototype development
NASA Technical Reports Server (NTRS)
Wang, Thomas D.; Mccomb, David G.; Kingston, Bradley R.; Dube, C. Michael; Poehls, Kenneth A.; Wanser, Keith
1989-01-01
The goal of this research program was to develop a high sensitivity, fiber optic, interferometric, three-axis magnetometer for interplanetary spacecraft applications. Dynamics Technology, Inc. (DTI) has successfully integrated a low noise, high bandwidth interferometer with high sensitivity metallic glass transducers. Also, DTI has developed sophisticated signal processing electronics and complete data acquisition, filtering, and display software. The sensor was packaged in a compact, low power and weight unit which facilitates deployment. The magnetic field sensor had subgamma sensitivity and a dynamic range of 10(exp 5) gamma in a 10 Hz bandwidth. Furthermore, the vector instrument exhibited the lowest noise level when only one axis was in operation. A system noise level of 1 gamma rms was observed in a 1 Hz bandwidth. However, with the other two channels operating, the noise level increased by about one order of magnitude. Higher system noise was attributed to cross-channel interference among the dither fields.
Child anxiety and parenting in England and Italy: the moderating role of maternal warmth.
Raudino, Alessandra; Murray, Lynne; Turner, Corinne; Tsampala, Eirini; Lis, Adriana; De Pascalis, Leonardo; Cooper, Peter J
2013-12-01
Parenting factors have been implicated in the aetiology and maintenance of child anxiety. Most research has been correlational with little experimental or longitudinal work. Cross-cultural comparison could be illuminating. A comparison of Italian and British children and their mothers was conducted. A sample of 8- to 10-year old children, 60 Italian and 49 English, completed the Spence Child Anxiety Scale. Mothers also completed two questionnaires of parenting: the Skills of Daily Living Checklist (assessing maternal autonomy granting) and the Parent-Child Interaction Questionnaire (assessing maternal intrusiveness). Parenting was assessed in two video-recorded blindly rated mother-child interaction tasks, the 'belt-buckling tasks and the 'etch-a-sketch', providing objective indices of overcontrol, warmth, lack of autonomy granting, and overprotection. There were no differences between the children in overall anxiety and specific forms of anxiety. Parenting, however, was markedly different for the two countries. Compared to English mothers, on the two questionnaires, Italian mothers were significantly less autonomy granting and more intrusive; and in terms of the observed indices, a significantly greater proportion of the Italian mothers displayed a high level of both overprotection and overcontrol, and a low level of autonomy granting. Notably, Italian mothers evidenced significantly more warmth than English mothers; and maternal warmth was found to moderate the impact of self-reported maternal intrusiveness on the level of both overall child anxiety and the level of child separation anxiety; and it also moderated the relationship between both observed maternal intrusiveness and overall child anxiety and observed maternal overprotectiveness and child separation anxiety. Although, compared to the British mothers, the Italian mothers were more likely to evidence high levels of parenting behaviours previously found to be anxiogenic, the high levels of warmth displayed by these mothers to their children appears to have neutralised the adverse impact of these behaviours. © 2013 The Authors. Journal of Child Psychology and Psychiatry © 2013 Association for Child and Adolescent Mental Health.
NASA Astrophysics Data System (ADS)
van Beurden, Maurice H. P. H.; Ijsselsteijn, Wijnand A.; de Kort, Yvonne A. W.
2011-03-01
Stereoscopic displays are known to offer a number of key advantages in visualizing complex 3D structures or datasets. The large majority of studies that focus on evaluating stereoscopic displays for professional applications use completion time and/or the percentage of correct answers to measure potential performance advantages. However, completion time and accuracy may not fully reflect all the benefits of stereoscopic displays. In this paper, we argue that perceived workload is an additional valuable indicator reflecting the extent to which users can benefit from using stereoscopic displays. We performed an experiment in which participants were asked to perform a visual path-tracing task within a convoluted 3D wireframe structure, varying in level of complexity of the visualised structure and level of disparity of the visualisation. The results showed that an optimal performance (completion time, accuracy and workload), depend both on task difficulty and disparity level. Stereoscopic disparity revealed a faster and more accurate task performance, whereas we observed a trend that performance on difficult tasks stands to benefit more from higher levels of disparity than performance on easy tasks. Perceived workload (as measured using the NASA-TLX) showed a similar response pattern, providing evidence that perceived workload is sensitive to variations in disparity as well as task difficulty. This suggests that perceived workload could be a useful concept, in addition to standard performance indicators, in characterising and measuring human performance advantages when using stereoscopic displays.
Nomura, Shosaku; Shouzu, Akira; Omoto, Seitarou; Inami, Norihito; Ueba, Tetsuya; Urase, Fumiaki; Maeda, Yasuhiro
2009-04-01
The aim of this study was to evaluate the significance of endothelial cell-derived microparticles (EDMP), angiopoietin-2 (Ang-2) and adiponectin in hyperlipidemic patients with and without type 2 diabetes mellitus, and to compare the two for the effects of eicosapentaenoic acid (EPA) on these markers. One hundred and twenty-six hyperlipidemic patients with and without type 2 diabetes mellitus received EPA 1,800 mg daily, and 50 of the patients were non-diabetic. EDMP and Ang-2 levels prior to treatment were higher in diabetic patients than in non-diabetic patients, whereas adiponectin levels were lower in diabetics. When diabetic patients were classified into two groups on the basis of Ang-2 levels, the levels of all markers remained unchanged in those without a high Ang-2 level after EPA treatment. In contrast, all markers except for adiponectin were decreased significantly in diabetic patients with high Ang-2 levels after 6 months of EPA treatment. These diabetic patients with high Ang-2 levels displayed a more significant increase in adiponectin levels after EPA treatment than those who did not. These results suggest that EPA possesses an adiponectin-dependent anti-atherosclerotic effect and may be beneficial for the prevention of vascular complications in diabetic patients with high Ang-2 levels.
[Different responses of DD/He and CC57BR/Mv mice to fasting].
Baginskaia, N V; Vasil'eva, E D; Il'nitskaia, S I; Kaledin, V I
2004-03-01
Reaction to fasting of 2 mice strains differing in their sensitivity to spontaneous and induced hepatocarcinogenesis, has been investigated. It was shown that mice of both strains displayed similar stress reaction after 3-day fasting manifested in increase in blood corticosterone level; and decrease in testosterone level. At the same time, both strains demonstrated opposite changes at tissue- and enzyme levels in the liver. It was shown that DD/He mice, highly sensitive to induction of liver tumors, were characterized by significant increase in tyrosine aminotransferase (TAT) activity and reduction of lipid droplets in hepatocytes. CC57BR/Mv mice, demonstrating high frequency of spontaneous hepatomas and insensitive to induction of such tumors, were characterized by a decrease in the TAT activity and fatty infiltration of the liver.
Where have we gone wrong? Perceptual load does not affect selective attention.
Benoni, Hanna; Tsal, Yehoshua
2010-06-18
The theory of perceptual load (Lavie & Tsal, 1994) proposes that with low load in relevant processing left over resources spill over to process irrelevant distractors. Interference could only be prevented under High-Load Conditions where relevant processing exhausts attentional resources. The theory is based primarily on the finding that distractor interference obtained in low load displays, when the target appears alone, is eliminated in high load displays when it is embedded among neutral letters. However, a possible alternative interpretation of this effect is that the distractor is similarly processed in both displays, yet its interference in the large displays is diluted by the presence of the neutral letters. We separated the possible effects of load and dilution by adding dilution displays that were high in dilution and low in perceptual load. In the first experiment these displays contained as many letters as the high load displays, but their neutral letters were clearly distinguished from the target, thereby allowing for a low load processing mode. In the second experiment we presented identical multicolor displays in the Dilution and High-Load Conditions. However, in the former the target color was known in advance (thereby preserving a low load processing mode) whereas in the latter it was not. In both experiments distractor interference was completely eliminated under the Dilution Condition. Thus, it is dilution not perceptual load affecting distractor processing. 2010 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Milo-Shussman, Yael
2017-01-01
The classroom display in elementary schools usually reflects the teacher's efforts and vision. Upon entering an elementary school classroom one may often encounter visual overload. How can teachers determine the appropriate amount of elements to be on display? How can they create the accurate recipe for pleasant and efficient displays? It seems…
Ultra-high contrast retinal display system for single photoreceptor psychophysics
Domdei, Niklas; Domdei, Lennart; Reiniger, Jenny L.; Linden, Michael; Holz, Frank G.; Roorda, Austin; Harmening, Wolf M.
2017-01-01
Due to the enormous dynamic range of human photoreceptors in response to light, studying their visual function in the intact retina challenges the stimulation hardware, specifically with regard to the displayable luminance contrast. The adaptive optics scanning laser ophthalmoscope (AOSLO) is an optical platform that focuses light to extremely small retinal extents, approaching the size of single photoreceptor cells. However, the current light modulation techniques produce spurious visible backgrounds which fundamentally limit experimental options. To remove unwanted background light and to improve contrast for high dynamic range visual stimulation in an AOSLO, we cascaded two commercial fiber-coupled acousto-optic modulators (AOMs) and measured their combined optical contrast. By compensating for zero-point differences in the individual AOMs, we demonstrate a multiplicative extinction ratio in the cascade that was in accordance with the extinction ratios of both single AOMs. When latency differences in the AOM response functions were individually corrected, single switch events as short as 50 ns with radiant power contrasts up to 1:1010 were achieved. This is the highest visual contrast reported for any display system so far. We show psychophysically that this contrast ratio is sufficient to stimulate single foveal photoreceptor cells with small and bright enough visible targets that do not contain a detectable background. Background-free stimulation will enable photoreceptor testing with custom adaptation lights. Furthermore, a larger dynamic range in displayable light levels can drive photoreceptor responses in cones as well as in rods. PMID:29359094
Visualization of the Eastern Renewable Generation Integration Study: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gruchalla, Kenny; Novacheck, Joshua; Bloom, Aaron
The Eastern Renewable Generation Integration Study (ERGIS), explores the operational impacts of the wide spread adoption of wind and solar photovoltaics (PV) resources in the U.S. Eastern Interconnection and Quebec Interconnection (collectively, EI). In order to understand some of the economic and reliability challenges of managing hundreds of gigawatts of wind and PV generation, we developed state of the art tools, data, and models for simulating power system operations using hourly unit commitment and 5-minute economic dispatch over an entire year. Using NREL's high-performance computing capabilities and new methodologies to model operations, we found that the EI, as simulated withmore » evolutionary change in 2026, could balance the variability and uncertainty of wind and PV at a 5-minute level under a variety of conditions. A large-scale display and a combination of multiple coordinated views and small multiples were used to visually analyze the four large highly multivariate scenarios with high spatial and temporal resolutions. state of the art tools, data, and models for simulating power system operations using hourly unit commitment and 5-minute economic dispatch over an entire year. Using NRELs high-performance computing capabilities and new methodologies to model operations, we found that the EI, as simulated with evolutionary change in 2026, could balance the variability and uncertainty of wind and PV at a 5-minute level under a variety of conditions. A large-scale display and a combination of multiple coordinated views and small multiples were used to visually analyze the four large highly multivariate scenarios with high spatial and temporal resolutions.« less
Engineering of Semiconductor Nanocrystals for Light Emitting Applications
Todescato, Francesco; Fortunati, Ilaria; Minotto, Alessandro; Signorini, Raffaella; Jasieniak, Jacek J.; Bozio, Renato
2016-01-01
Semiconductor nanocrystals are rapidly spreading into the display and lighting markets. Compared with liquid crystal and organic LED displays, nanocrystalline quantum dots (QDs) provide highly saturated colors, wide color gamut, resolution, rapid response time, optical efficiency, durability and low cost. This remarkable progress has been made possible by the rapid advances in the synthesis of colloidal QDs and by the progress in understanding the intriguing new physics exhibited by these nanoparticles. In this review, we provide support to the idea that suitably engineered core/graded-shell QDs exhibit exceptionally favorable optical properties, photoluminescence and optical gain, while keeping the synthesis facile and producing QDs well suited for light emitting applications. Solid-state laser emitters can greatly profit from QDs as efficient gain materials. Progress towards fabricating low threshold, solution processed DFB lasers that are optically pumped using one- and two-photon absorption is reviewed. In the field of display technologies, the exploitation of the exceptional photoluminescence properties of QDs for LCD backlighting has already advanced to commercial levels. The next big challenge is to develop the electroluminescence properties of QD to a similar state. We present an overview of QLED devices and of the great perspectives for next generation display and lighting technologies. PMID:28773794
Oxidation resistant high creep strength austenitic stainless steel
Brady, Michael P.; Pint, Bruce A.; Liu, Chain-Tsuan; Maziasz, Philip J.; Yamamoto, Yukinori; Lu, Zhao P.
2010-06-29
An austenitic stainless steel displaying high temperature oxidation and creep resistance has a composition that includes in weight percent 15 to 21 Ni, 10 to 15 Cr, 2 to 3.5 Al, 0.1 to 1 Nb, and 0.05 to 0.15 C, and that is free of or has very low levels of N, Ti and V. The alloy forms an external continuous alumina protective scale to provide a high oxidation resistance at temperatures of 700 to 800.degree. C. and forms NbC nanocarbides and a stable essentially single phase fcc austenitic matrix microstructure to give high strength and high creep resistance at these temperatures.
Microwave spectroscopy of high-L Rydberg states of nickel
NASA Astrophysics Data System (ADS)
Lindsay, Mark D.; Keele, Julie A.; Woods, Shannon L.; Lundeen, Stephen R.
2010-03-01
High-L non-penetrating Rydberg levels of nickel display a fine structure pattern consisting of six levels for each value of L. This pattern was studied recently with the optical RESIS technique, determining initial values of the quadrupole moment and polarizabilities of the ^2D5/2 ground state of Ni^+ [1]. Measurements are now in progress using the microwave RESIS technique [2], which promises much more precise measurements of the fine structure and of the related core properties, including the permanent hexadecapole moment.[4pt] [1] Julie A. Keele, et. al., to be published, Phys. Rev. A[0pt] [2] M.E. Hanni, et. al., Phys. Rev. A 78, 062510 (2008)
Accommodation response measurements for integral 3D image
NASA Astrophysics Data System (ADS)
Hiura, H.; Mishina, T.; Arai, J.; Iwadate, Y.
2014-03-01
We measured accommodation responses under integral photography (IP), binocular stereoscopic, and real object display conditions, and viewing conditions of binocular and monocular viewing conditions. The equipment we used was an optometric device and a 3D display. We developed the 3D display for IP and binocular stereoscopic images that comprises a high-resolution liquid crystal display (LCD) and a high-density lens array. The LCD has a resolution of 468 dpi and a diagonal size of 4.8 inches. The high-density lens array comprises 106 x 69 micro lenses that have a focal length of 3 mm and diameter of 1 mm. The lenses are arranged in a honeycomb pattern. The 3D display was positioned 60 cm from an observer under IP and binocular stereoscopic display conditions. The target was presented at eight depth positions relative to the 3D display: 15, 10, and 5 cm in front of the 3D display, on the 3D display panel, and 5, 10, 15 and 30 cm behind the 3D display under the IP and binocular stereoscopic display conditions. Under the real object display condition, the target was displayed on the 3D display panel, and the 3D display was placed at the eight positions. The results suggest that the IP image induced more natural accommodation responses compared to the binocular stereoscopic image. The accommodation responses of the IP image were weaker than those of a real object; however, they showed a similar tendency with those of the real object under the two viewing conditions. Therefore, IP can induce accommodation to the depth positions of 3D images.
The effects of ambient music on simulated anaesthesia monitoring.
Sanderson, P M; Tosh, N; Philp, S; Rudie, J; Watson, M O; Russell, W J
2005-11-01
We examined the effect of no music, classical music or rock music on simulated patient monitoring. Twenty-four non-anaesthetist participants with high or low levels of musical training were trained to monitor visual and auditory displays of patients' vital signs. In nine anaesthesia test scenarios, participants were asked every 50-70 s whether one of five vital signs was abnormal and the trend of its direction. Abnormality judgements were unaffected by music or musical training. Trend judgements were more accurate when music was playing (p = 0.0004). Musical participants reported trends more accurately (p = 0.004), and non-musical participants tended to benefit more from music than did the musical participants (p = 0.063). Music may provide a pitch and rhythm standard from which participants can judge changes in vital signs from auditory displays. Nonetheless, both groups reported that it was easier to monitor the patient with no music (p = 0.0001), and easier to rely upon the auditory displays with no music (p = 0.014).
A Cu2+-selective fluorescent chemosensor based on BODIPY with two pyridine ligands and logic gate
NASA Astrophysics Data System (ADS)
Huang, Liuqian; Zhang, Jing; Yu, Xiaoxiu; Ma, Yifan; Huang, Tianjiao; Shen, Xi; Qiu, Huayu; He, Xingxing; Yin, Shouchun
2015-06-01
A novel near-infrared fluorescent chemosensor based on BODIPY (Py-1) has been synthesized and characterized. Py-1 displays high selectivity and sensitivity for sensing Cu2+ over other metal ions in acetonitrile. Upon addition of Cu2+ ions, the maximum absorption band of Py-1 in CH3CN displays a red shift from 603 to 608 nm, which results in a visual color change from pink to blue. When Py-1 is excited at 600 nm in the presence of Cu2+, the fluorescent emission intensity of Py-1 at 617 nm is quenched over 86%. Notably, the complex of Py-1-Cu2+ can be restored with the introduction of EDTA or S2-. Consequently, an IMPLICATION logic gate at molecular level operating in fluorescence mode with Cu2+ and S2- as chemical inputs can be constructed. Finally, based on the reversible and reproducible system, a nanoscale sequential memory unit displaying "Writing-Reading-Erasing-Reading" functions can be integrated.
Katchman, Benjamin A.; Smith, Joseph T.; Obahiagbon, Uwadiae; Kesiraju, Sailaja; Lee, Yong-Kyun; O’Brien, Barry; Kaftanoglu, Korhan; Blain Christen, Jennifer; Anderson, Karen S.
2016-01-01
Point-of-care molecular diagnostics can provide efficient and cost-effective medical care, and they have the potential to fundamentally change our approach to global health. However, most existing approaches are not scalable to include multiple biomarkers. As a solution, we have combined commercial flat panel OLED display technology with protein microarray technology to enable high-density fluorescent, programmable, multiplexed biorecognition in a compact and disposable configuration with clinical-level sensitivity. Our approach leverages advances in commercial display technology to reduce pre-functionalized biosensor substrate costs to pennies per cm2. Here, we demonstrate quantitative detection of IgG antibodies to multiple viral antigens in patient serum samples with detection limits for human IgG in the 10 pg/mL range. We also demonstrate multiplexed detection of antibodies to the HPV16 proteins E2, E6, and E7, which are circulating biomarkers for cervical as well as head and neck cancers. PMID:27374875
Katchman, Benjamin A; Smith, Joseph T; Obahiagbon, Uwadiae; Kesiraju, Sailaja; Lee, Yong-Kyun; O'Brien, Barry; Kaftanoglu, Korhan; Blain Christen, Jennifer; Anderson, Karen S
2016-07-04
Point-of-care molecular diagnostics can provide efficient and cost-effective medical care, and they have the potential to fundamentally change our approach to global health. However, most existing approaches are not scalable to include multiple biomarkers. As a solution, we have combined commercial flat panel OLED display technology with protein microarray technology to enable high-density fluorescent, programmable, multiplexed biorecognition in a compact and disposable configuration with clinical-level sensitivity. Our approach leverages advances in commercial display technology to reduce pre-functionalized biosensor substrate costs to pennies per cm(2). Here, we demonstrate quantitative detection of IgG antibodies to multiple viral antigens in patient serum samples with detection limits for human IgG in the 10 pg/mL range. We also demonstrate multiplexed detection of antibodies to the HPV16 proteins E2, E6, and E7, which are circulating biomarkers for cervical as well as head and neck cancers.
JuxtaView - A tool for interactive visualization of large imagery on scalable tiled displays
Krishnaprasad, N.K.; Vishwanath, V.; Venkataraman, S.; Rao, A.G.; Renambot, L.; Leigh, J.; Johnson, A.E.; Davis, B.
2004-01-01
JuxtaView is a cluster-based application for viewing ultra-high-resolution images on scalable tiled displays. We present in JuxtaView, a new parallel computing and distributed memory approach for out-of-core montage visualization, using LambdaRAM, a software-based network-level cache system. The ultimate goal of JuxtaView is to enable a user to interactively roam through potentially terabytes of distributed, spatially referenced image data such as those from electron microscopes, satellites and aerial photographs. In working towards this goal, we describe our first prototype implemented over a local area network, where the image is distributed using LambdaRAM, on the memory of all nodes of a PC cluster driving a tiled display wall. Aggressive pre-fetching schemes employed by LambdaRAM help to reduce latency involved in remote memory access. We compare LambdaRAM with a more traditional memory-mapped file approach for out-of-core visualization. ?? 2004 IEEE.
Image Geometric Corrections for a New EMCCD-based Dual Modular X-ray Imager
Qu, Bin; Huang, Ying; Wang, Weiyuan; Cartwright, Alexander N.; Titus, Albert H.; Bednarek, Daniel R.; Rudin, Stephen
2012-01-01
An EMCCD-based dual modular x-ray imager was recently designed and developed from the component level, providing a high dynamic range of 53 dB and an effective pixel size of 26 μm for angiography and fluoroscopy. The unique 2×1 array design efficiently increased the clinical field of view, and also can be readily expanded to an M×N array implementation. Due to the alignment mismatches between the EMCCD sensors and the fiber optic tapers in each module, the output images or video sequences result in a misaligned 2048×1024 digital display if uncorrected. In this paper, we present a method for correcting display registration using a custom-designed two layer printed circuit board. This board was designed with grid lines to serve as the calibration pattern, and provides an accurate reference and sufficient contrast to enable proper display registration. Results show an accurate and fine stitching of the two outputs from the two modules. PMID:22254882
Sim, L; Manthey, K; Stuckey, S
2007-06-01
A study to compare performance of the following display monitors for application as PACS CR diagnostic workstations is described. 1. Diagnostic quality, 3 Mega Pixel, 21 inch monochrome LCD monitors--Planar C3i. 2. Clinical review quality, 2 Mega Pixel, 21 inch colour LCD monitors--Planar PX212. Two sets of seventy radiological studies were presented to four senior radiologists on two occasions, using different displays on each occasion. The clinical condition used for this investigation was to query for the presence of a solitary pulmonary nodule. Receiver Operating Characteristic (ROC) curves were constructed for diagnostic performance for each presentation. Areas under the ROC curves (AUC) for diagnosis using different monitors were compared and the following results obtained: Monochrome AUC = 0.813 +/- 0.02, Colour AUC = 0.801 +/- 0.021. These results indicate that there is no statistically significant difference in the performance of these monitor types at a 95% confidence level.
Fab is the most efficient format to express functional antibodies by yeast surface display.
Sivelle, Coline; Sierocki, Raphaël; Ferreira-Pinto, Kelly; Simon, Stéphanie; Maillere, Bernard; Nozach, Hervé
2018-04-30
Multiple formats are available for engineering of monoclonal antibodies (mAbs) by yeast surface display, but they do not all lead to efficient expression of functional molecules. We therefore expressed four anti-tumor necrosis factor and two anti-IpaD mAbs as single-chain variable fragment (scFv), antigen-binding fragment (Fab) or single-chain Fabs and compared their expression levels and antigen-binding efficiency. Although the scFv and scFab formats are widely used in the literature, 2 of 6 antibodies were either not or weakly expressed. In contrast, all 6 antibodies expressed as Fab revealed strong binding and high affinity, comparable to that of the soluble form. We also demonstrated that the variations in expression did not affect Fab functionality and were due to variations in light chain display and not to misfolded dimers. Our results suggest that Fab is the most versatile format for the engineering of mAbs.
The Effects of Specialization and Sex on Anterior Y-Balance Performance in High School Athletes.
Miller, Madeline M; Trapp, Jessica L; Post, Eric G; Trigsted, Stephanie M; McGuine, Timothy A; Brooks, M Alison; Bell, David R
Sport specialization and movement asymmetry have been separately discussed as potential risk factors for lower extremity injury. Early specialization may lead to the development of movement asymmetries that can predispose an athlete to injury, but this has not been thoroughly examined. Athletes rated as specialized would exhibit greater between-limb anterior reach asymmetry and decreased anterior reach distance on the Y-balance test (YBT) as compared with nonspecialized high school athletes, and these differences would not be dependent on sex. Cross-sectional study. Level 3. Two hundred ninety-five athletes (117 male, 178 female; mean age, 15.6 ± 1.2 years) from 2 local high schools participating in basketball, soccer, volleyball, and tennis responded to a questionnaire regarding sport specialization status and performed trials of the YBT during preseason testing. Specialization was categorized according to 3 previously utilized specialization classification methods (single/multisport, 3-point scale, and 6-point scale), and interactions between specialization and sex with Y-balance performance were calculated using 2-way analyses of variance. Single-sport male athletes displayed greater anterior reach asymmetry than other interaction groups. A consistent main effect was observed for sex, with men displaying greater anterior asymmetry and decreased anterior reach distance than women. However, the interaction effects of specialization and sex on anterior Y-balance performance varied based on the classification method used. Single-sport male athletes displayed greater anterior reach asymmetry on the YBT than multisport and female athletes. Specialization classification method is important because the 6- and 3-point scales may not accurately identify balance abnormalities. Male athletes performed worse than female athletes on both of the Y-balance tasks. Clinicians should be aware that single-sport male athletes may display deficits in dynamic balance, potentially increasing their risk of injury.
Liu, Mali; Lu, Chihao; Li, Haifeng; Liu, Xu
2018-02-19
We propose a bifocal computational near eye light field display (bifocal computational display) and structure parameters determination scheme (SPDS) for bifocal computational display that achieves greater depth of field (DOF), high resolution, accommodation and compact form factor. Using a liquid varifocal lens, two single-focal computational light fields are superimposed to reconstruct a virtual object's light field by time multiplex and avoid the limitation on high refresh rate. By minimizing the deviation between reconstructed light field and original light field, we propose a determination framework to determine the structure parameters of bifocal computational light field display. When applied to different objective to SPDS, it can achieve high average resolution or uniform resolution display over scene depth range. To analyze the advantages and limitation of our proposed method, we have conducted simulations and constructed a simple prototype which comprises a liquid varifocal lens, dual-layer LCDs and a uniform backlight. The results of simulation and experiments with our method show that the proposed system can achieve expected performance well. Owing to the excellent performance of our system, we motivate bifocal computational display and SPDS to contribute to a daily-use and commercial virtual reality display.
Multimission helicopter information display technology
NASA Astrophysics Data System (ADS)
Terry, William S.
1995-06-01
A new Operator display subsystem is being incorporated as part of the next generation United States Navy (USN) helicopter avionics system to be integrated into the Multi-Mission Helicopter (MMH) which will replace both the SH-60B and the SH- 60F in 2001. This subsystem exploits state-of-the-art technology for the display hardware, the display driver hardware, information presentation methodologies, and software architecture. The technologies to be base technologies have evolved during the development period and the solution has been modified to include current elements including high resolution AMLCD color displays that are sunlight readable, highly reliable, and significantly lighter that CRT technology, as well as Reduced Instruction Set Computer (RISC) based high-performance display generators that have only recently become feasible to implement in a military aircraft. This paper describes the overall subsystem architecture, some detail on the individual elements along with supporting rationale, the manner in which the display subsystem provides the necessary tools to significantly enhance the performance of the weapon system through the vital Operator-System Interface. Also addressed is a summary of the evolution of design leading to the current approach to MMH Operator displays and display processing as well as the growth path that the MMH display subsystem will most likely follow as additional technology evolution occurs.
Dutra, Walderez O; Correa-Oliveira, Rodrigo; Dunne, David; Cecchini, Luiza Fosenca; Fraga, Lúcia; Roberts, Morven; Soares-Silveira, Alda Maria; Webster, Michelle; Yssel, Hans; Gollob, Kenneth J
2002-07-06
Human resistance to re-infection with S. mansoni is correlated with high levels of anti-soluble adult worm antigens (SWAP) IgE. Although it has been shown that IL-4 and IL-5 are crucial in establishing IgE responses in vitro, the active in vivo production of these cytokines by T cells, and the degree of polarization of Th2 vs. Th0 in human schistosomiasis is not known. To address this question, we determined the frequency of IL-4 and IFN-gamma or IL-5 and IL-2 producing lymphocytes from schistosomiasis patients with high or low levels of IgE anti-SWAP. Our analysis showed that high and low IgE-producers responded equally to schistosomiasis antigens as determined by proliferation. Moreover, patients from both groups displayed similar percentages of circulating lymphocytes. However, high IgE-producers had an increased percentage of activated CD4+ T cells as compared to the low IgE-producers. Moreover, intracellular cytokine analysis, after short-term stimulation with anti-CD3/CD28 mAbs, showed that IgE high-producers display an increase in the percentage of T lymphocytes expressing IL-4 and IL-5 as compared to IgE low-responders. A coordinate control of the frequency of IL-4 and IL-5 producing lymphocytes in IgE high, but not IgE low-responders, was observed. High IgE phenotype human schistosomiasis patients exhibit a coordinate regulation of IL-4 and IL-5 producing cells and the lymphocyte derived IL-4 comes from true polarized Th2 like cells, in the absence of measurable Th0 cells as measured by co-production of IL-4 and IFN-gamma.
Dutra, Walderez O; Correa-Oliveira, Rodrigo; Dunne, David; Cecchini, Luiza Fosenca; Fraga, Lúcia; Roberts, Morven; Soares-Silveira, Alda Maria; Webster, Michelle; Yssel, Hans; Gollob, Kenneth J
2002-01-01
Background Human resistance to re-infection with S. mansoni is correlated with high levels of anti-soluble adult worm antigens (SWAP) IgE. Although it has been shown that IL-4 and IL-5 are crucial in establishing IgE responses in vitro, the active in vivo production of these cytokines by T cells, and the degree of polarization of Th2 vs. Th0 in human schistosomiasis is not known. To address this question, we determined the frequency of IL-4 and IFN-γ or IL-5 and IL-2 producing lymphocytes from schistosomiasis patients with high or low levels of IgE anti-SWAP. Results Our analysis showed that high and low IgE-producers responded equally to schistosomiasis antigens as determined by proliferation. Moreover, patients from both groups displayed similar percentages of circulating lymphocytes. However, high IgE-producers had an increased percentage of activated CD4+ T cells as compared to the low IgE-producers. Moreover, intracellular cytokine analysis, after short-term stimulation with anti-CD3/CD28 mAbs, showed that IgE high-producers display an increase in the percentage of T lymphocytes expressing IL-4 and IL-5 as compared to IgE low-responders. A coordinate control of the frequency of IL-4 and IL-5 producing lymphocytes in IgE high, but not IgE low-responders, was observed. Conclusions High IgE phenotype human schistosomiasis patients exhibit a coordinate regulation of IL-4 and IL-5 producing cells and the lymphocyte derived IL-4 comes from true polarized Th2 like cells, in the absence of measurable Th0 cells as measured by co-production of IL-4 and IFN-γ. PMID:12100735
Diluting the burden of load: perceptual load effects are simply dilution effects.
Tsal, Yehoshua; Benoni, Hanna
2010-12-01
The substantial distractor interference obtained for small displays when the target appears alone is reduced in large displays when the target is embedded among neutral letters. This finding has been interpreted as reflecting low-load and high-load processing, respectively, thereby supporting the theory of perceptual load (Lavie & Tsal, 1994). However, a possible alternative interpretation of this effect is that the distractor is similarly processed in both displays, yet its interference in the large ones is diluted by the presence of the neutral letters. We separated the effects of load and dilution by introducing dilution displays. They contained as many letters as the high-load displays but were clearly distinguished from the target, thus allowing for a low-load processing mode. Distractor interference obtained under both the low-load and high-load conditions disappeared under the dilution condition. Hence, the display size effect traditionally misattributed to perceptual load is fully accounted for by dilution. Furthermore, when dilution is controlled for, it is high load not low load producing greater interference.
Evaluation of a pilot workload metric for simulated VTOL landing tasks
NASA Technical Reports Server (NTRS)
North, R. A.; Graffunder, K.
1979-01-01
A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Multivariate discriminant functions were formed from conventional flight performance and/or visual response variables to maximize detection of experimental differences. The flight performance variable discriminant showed maximum differentiation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition/trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus, represented higher workload levels.
Batteryless magneto-driven portable radiac
Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Wolf, M.A.; Umbarger, C.J.
1984-10-19
A hand-powerd alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Mueller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.
CERESVis: A QC Tool for CERES that Leverages Browser Technology for Data Validation
NASA Astrophysics Data System (ADS)
Chu, C.; Sun-Mack, S.; Heckert, E.; Chen, Y.; Doelling, D.
2015-12-01
In this poster, we are going to present three user interfaces that CERES team uses to validate pixel-level data. Besides our home grown tools, we will aslo present the browser technology that we use to provide interactive interfaces, such as jquery, HighCharts and Google Earth. We pass data to the users' browsers and use the browsers to do some simple computations. The three user interfaces are: Thumbnails -- it displays hundrends images to allow users to browse 24-hour data files in few seconds. Multiple-synchronized cursors -- it allows users to compare multiple images side by side. Bounding Boxes and Histograms -- it allows users to draw multiple bounding boxes on an image and the browser computes/display the histograms.
Batteryless magneto-driven portable radiac
Waechter, David A.; Bjarke, George O.; Trujillo, Faustin; Wolf, Michael A.; Umbarger, C. John
1986-01-01
A hand-powered alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Muller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warrant, Marilyn M.; Garcia, Rudy J.; Zhang, Pengchu
2004-09-15
Tomcat-Projects_RF is a software package for analyzing sensor data obtained from a database and displaying the results with Java Servlet Pages (JSP). SQL Views into the dataset are tailored for personnel having different roles in monitoring the items in a storage facility. For example, an inspector, a host treaty compliance officer, a system engineer and software developers were the users identified that would need to access data at different levels of detail, The analysis provides a high level status of the storage facility and allows the user to go deeper into the data details if the user desires.
Type of packaging affects the colour stability of vitamin E enriched beef.
Nassu, Renata T; Uttaro, Bethany; Aalhus, Jennifer L; Zawadski, Sophie; Juárez, Manuel; Dugan, Michael E R
2012-12-01
Colour stability is a very important parameter for meat retail display, as appearance of the product is the deciding factor for consumers at time of purchase. This study investigated the possibility of extending appearance shelf-life through the combined use of packaging method (overwrapping - OVER, modified atmosphere - MAP, vacuum skin packaging - VSP and a combination of modified atmosphere and vacuum skin packaging - MAPVSP) and antioxidants (vitamin E enriched beef). Retail attributes (appearance, lean colour, % surface discolouration), as well as colour space analysis of images for red, green and blue parameters were measured over 18days. MAPVSP provided the most desirable retail appearance during the first 4days of retail display, while VSP-HB had the best colour stability. Overall, packaging type was more influential than α-tocopherol levels on meat colour stability, although α-tocopherol levels (>4μgg(-1) meat) had a protective effect when using high oxygen packaging methods. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Maner, Jon K; Miller, Saul L; Moss, Justin H; Leo, Jennifer L; Plant, E Ashby
2012-07-01
This article presents an evolutionary framework for identifying the characteristics people use to categorize members of their social world. Findings suggest that fundamental social motives lead people to implicitly categorize social targets based on whether those targets display goal-relevant phenotypic traits. A mate-search prime caused participants to categorize opposite-sex targets (but not same-sex targets) based on their level of physical attractiveness (Experiment 1). A mate-guarding prime interacted with relationship investment, causing participants to categorize same-sex targets (but not opposite-sex targets) based on their physical attractiveness (Experiment 2). A self-protection prime interacted with chronic beliefs about danger, increasing participants' tendency to categorize targets based on their racial group membership (Black or White; Experiment 3). This work demonstrates that people categorize others based on whether they display goal-relevant characteristics reflecting high levels of perceived desirability or threat. Social categorization is guided by fundamental evolved motives designed to enhance adaptive social outcomes. PsycINFO Database Record (c) 2012 APA, all rights reserved
The Influence of Environmental Consequences and Internalizing Symptoms on Children's Tic Severity.
Eaton, Cyd K; Jones, Anna M; Gutierrez-Colina, Ana M; Ivey, Emily K; Carlson, Olivia; Melville, Lauren; Kardon, Patricia; Blount, Ronald L
2017-04-01
Although there is evidence that environmental consequences for displaying tics and internalizing symptoms are related to tic severity in children with TS, less is known about the inter-relationships of these variables or how these factors jointly contribute to tic severity. This study included 45 children with Tourette syndrome. Caregivers reported on children's environmental consequences for displaying tics, internalizing symptoms, and tic severity. Results indicated that children with higher levels of internalizing symptoms experienced significantly more environmental consequences for displaying tics. Children with higher levels of separation anxiety symptoms demonstrated significantly greater tic severity. Environmental consequences for displaying tics accounted for significantly more variance in predicting tic severity than anxiety symptoms. This preliminary evidence suggests that environmental consequences for displaying tics, such as receiving accommodations or attention from others, have a greater influence on children's tic severity than emotional factors.
Re-Imagining Archival Display: Creating User-Friendly Finding Aids
ERIC Educational Resources Information Center
Daines, J. Gordon, III; Nimer, Cory L.
2011-01-01
This article examines how finding aids are structured and delivered, considering alternative approaches. It suggests that single-level displays, those that present a single component of a multilevel description to users at a time, have the potential to transform the delivery and display of collection information while improving the user…
Oil defect detection of electrowetting display
NASA Astrophysics Data System (ADS)
Chiang, Hou-Chi; Tsai, Yu-Hsiang; Yan, Yung-Jhe; Huang, Ting-Wei; Mang, Ou-Yang
2015-08-01
In recent years, transparent display is an emerging topic in display technologies. Apply in many fields just like mobile device, shopping or advertising window, and etc. Electrowetting Display (EWD) is one kind of potential transparent display technology advantages of high transmittance, fast response time, high contrast and rich color with pigment based oil system. In mass production process of Electrowetting Display, oil defects should be found by Automated Optical Inspection (AOI) detection system. It is useful in determination of panel defects for quality control. According to the research of our group, we proposed a mechanism of AOI detection system detecting the different kinds of oil defects. This mechanism can detect different kinds of oil defect caused by oil overflow or material deteriorated after oil coating or driving. We had experiment our mechanism with a 6-inch Electrowetting Display panel from ITRI, using an Epson V750 scanner with 1200 dpi resolution. Two AOI algorithms were developed, which were high speed method and high precision method. In high precision method, oil jumping or non-recovered can be detected successfully. This mechanism of AOI detection system can be used to evaluate the oil uniformity in EWD panel process. In the future, our AOI detection system can be used in quality control of panel manufacturing for mass production.
Chan, Alan H S; Hoffmann, Errol R
2015-01-01
Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.
Second Breakdown of 18V Grounded Gate NMOS induced by the Kirk Effect under Electrostatic Discharge
NASA Astrophysics Data System (ADS)
Jeon, Byung-Chul; Lee, Seung-Chul; Han, Min-Koo
2003-09-01
Electrostatic Discharge (ESD) failure mechanisms of 18V grounded gate NMOS (GGNMOS) for liquid crystal display driver IC (LDI) applications are investigated and effects of layout design parameters on the ESD immunity level are analyzed. Experimental results show that 18V GGNMOS exhibits snapback characteristics and the ESD immunity level is rather high when XO (N-drift overlap over n+ source/drain) is sufficiently large, while GGNMOS does not exhibit the sustaining region and is very vulnerable to ESD stress when XO is relatively small. Simulation results show that the ESD failure mechanism of 18V GGNMOS could be the low-temperature second breakdown induced by the Kirk effect. It is inferred that a certain amount of XO is indispensable to ensure snapback characteristics and high ESD immunity level. Simulation results also show that the ESD immunity level is increased as drain contact to gate space (DCGS) is increased.
The effect of monocular target blur on simulated telerobotic manipulation
NASA Technical Reports Server (NTRS)
Liu, Andrew; Stark, Lawrence
1991-01-01
A simulation involving three types of telerobotic tasks that require information about the spatial position of objects is reported. This is similar to the results of psychophysical experiments examining the effect of blur on stereoacuity. It is suggested that other psychophysical experimental results could be used to predict operator performance for other telerobotic tasks. It is demonstrated that refractive errors in the helmet-mounted stereo display system can affect performance in the three types of telerobotic tasks. The results of two sets of experiments indicate that monocular target blur of two diopters or more degrades stereo display performance to the level of monocular displays. This indicates that moderate levels of visual degradation that affect the operator's stereoacuity may eliminate the performance advantage of stereo displays.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-01
... Highly Migratory Species; Exempted Fishing, Scientific Research, Display, and Chartering Permits; Letters... Permits (EFPs), Scientific Research Permits (SRPs), Display Permits, Letters of Acknowledgment (LOAs), and... scientific research, the acquisition of information and data, the enhancement of safety at sea, the purpose...
Sepsis-induced activation of endogenous GLP-1 system is enhanced in type 2 diabetes.
Perl, Sivan H; Bloch, Olga; Zelnic-Yuval, Dana; Love, Itamar; Mendel-Cohen, Lior; Flor, Hadar; Rapoport, Micha J
2018-05-01
High levels of circulating GLP-1 are associated with severity of sepsis in critically ill nondiabetic patients. Whether patients with type 2 diabetes (T2D) display different activation of the endogenous GLP-1 system during sepsis and whether it is affected by diabetes-related metabolic parameters are not known. Serum levels of GLP-1 (total and active forms) and its inhibitor enzyme sDPP-4 were determined by ELISA on admission and after 2 to 4 days in 37 sepsis patients with (n = 13) and without T2D (n = 24) and compared to normal healthy controls (n = 25). Correlations between GLP-1 system activation and clinical, inflammatory, and diabetes-related metabolic parameters were performed. A 5-fold (P < .001) and 2-fold (P < .05) increase in active and total GLP-1 levels, respectively, were found on admission as compared to controls. At 2 to 4 days from admission, the level of active GLP-1 forms in surviving patients were decreased significantly (P < .005), and positively correlated with inflammatory marker CRP (r = 0.33, P = .05). T2D survivors displayed a similar but more enhanced pattern of GLP-1 response than nondiabetic survivors. Nonsurvivors demonstrate an early extreme increase of both total and active GLP-1 forms, 9.5-fold and 5-fold, respectively (P < .05). The initial and late levels of circulating GLP-1 inhibitory enzyme sDPP-4 were twice lower in all studied groups (P < .001), compared with healthy controls. Taken together, these data indicate that endogenous GLP-1 system is activated during sepsis. Patients with T2D display an enhanced and prolonged activation as compared to nondiabetic patients. Extreme early increased GLP-1 levels during sepsis indicate poor prognosis. Copyright © 2018 John Wiley & Sons, Ltd.
Bellon, Jennifer R; Yang, Fei; Day, Martin P; Inglis, Debra L; Chambers, Paul J
2015-10-01
To remain competitive in increasingly overcrowded markets, yeast strain development programmes are crucial for fermentation-based food and beverage industries. In a winemaking context, there are many yeast phenotypes that stand to be improved. For example, winemakers endeavouring to produce sweet dessert wines wrestle with fermentation challenges particular to fermenting high-sugar juices, which can lead to elevated volatile acidity levels and extended fermentation times. In the current study, we used natural yeast breeding techniques to generate Saccharomyces spp. interspecific hybrids as a non-genetically modified (GM) strategy to introduce targeted improvements in important, wine-relevant traits. The hybrids were generated by mating a robust wine strain of Saccharomyces cerevisiae with a wine isolate of Saccharomyces bayanus, a species previously reported to produce wines with low concentrations of acetic acid. Two hybrids generated from the cross showed robust fermentation properties in high-sugar grape juice and produced botrytised Riesling wines with much lower concentrations of acetic acid relative to the industrial wine yeast parent. The hybrids also displayed suitability for icewine production when bench-marked against an industry standard icewine yeast, by delivering icewines with lower levels of acetic acid. Additionally, the hybrid yeast produced wines with novel aroma and flavour profiles and established that choice of yeast strain impacts on wine colour. These new hybrid yeasts display the desired targeted fermentation phenotypes from both parents, robust fermentation in high-sugar juice and the production of wines with low volatile acidity, thus establishing their suitability for wine styles that are traditionally troubled by excessive volatile acidity levels.
NUV Spectroscopic Studies of Eta Car's Weigelt D across the 2003.5 Minimum
NASA Technical Reports Server (NTRS)
Ivarsson, S.; Nielsen, K. E.; Gull, T. R.; Hillier, J. D.
2006-01-01
HST/STIS high dispersion, high spatial resolution spectra in the near UV (2424-2705A) were recorded of Weigelt D, located 0.25" from Eta Carinae, before, during and after the star's 2003.5 minimum. Most nebular emission, including Lyman-alpha pumped Fe II and [Fe III] lines show phase dependent variations with disappearance at the minimum and reappearance a few months later. Circumstellar absorptions increase at minimum, especially in the Fe II resonance lines originating not only from ground levels but also meta stable levels well above the ground levels. These ionization/excitation effects can be explained by a sudden change in UV flux reaching the blobs, likely due to a line-of-sight obscuration of the hotter companion star, Eta Car B, recently discovered by Iping et al. (poster, this meeting). The scattered starlight seen towards Weigelt D display noticeable different line profiles than the direct starlight from Eta Carinae. P-Cygni absorption profiles in Fe II stellar lines observed directly towards Eta Carinae, show terminal velocities up to -550 km/s. However, scattered starlight of Weigelt D display significant lower velocities ranging from -40 to -150 km/s.We interpret this result to be indicative that no absorbing Fe II wind structure exists between the Central source and Weigelt D. The lower velocity absorption appears to be connected to the outer Fe II wind structure of Eta Car A extending beyond Weigelt D intersecting the observer's line of sight. This result is consistent with the highly extended wind of Eta Car A.
Brain activity correlates with emotional perception induced by dynamic avatars.
Goldberg, Hagar; Christensen, Andrea; Flash, Tamar; Giese, Martin A; Malach, Rafael
2015-11-15
An accurate judgment of the emotional state of others is a prerequisite for successful social interaction and hence survival. Thus, it is not surprising that we are highly skilled at recognizing the emotions of others. Here we aimed to examine the neuronal correlates of emotion recognition from gait. To this end we created highly controlled dynamic body-movement stimuli based on real human motion-capture data (Roether et al., 2009). These animated avatars displayed gait in four emotional (happy, angry, fearful, and sad) and speed-matched neutral styles. For each emotional gait and its equivalent neutral gait, avatars were displayed at five morphing levels between the two. Subjects underwent fMRI scanning while classifying the emotions and the emotional intensity levels expressed by the avatars. Our results revealed robust brain selectivity to emotional compared to neutral gait stimuli in brain regions which are involved in emotion and biological motion processing, such as the extrastriate body area (EBA), fusiform body area (FBA), superior temporal sulcus (STS), and the amygdala (AMG). Brain activity in the amygdala reflected emotional awareness: for visually identical stimuli it showed amplified stronger response when the stimulus was perceived as emotional. Notably, in avatars gradually morphed along an emotional expression axis there was a parametric correlation between amygdala activity and emotional intensity. This study extends the mapping of emotional decoding in the human brain to the domain of highly controlled dynamic biological motion. Our results highlight an extensive level of brain processing of emotional information related to body language, which relies mostly on body kinematics. Copyright © 2015. Published by Elsevier Inc.
Advanced glycation endproducts in 35 types of seafood products consumed in eastern China
NASA Astrophysics Data System (ADS)
Wang, Jing; Li, Zhenxing; Pavase, Ramesh Tushar; Lin, Hong; Zou, Long; Wen, Jie; Lv, Liangtao
2016-08-01
Advanced glycation endproducts (AGEs) have been recognized as hazards in processed foods that can induce chronic diseases such as cardiovascular disease, diabetes, and diabetic nephropathy. In this study, we investigated the AGEs contents of 35 types of industrial seafood products that are consumed frequently in eastern China. Total fluorescent AGEs level and Nɛ-carboxymethyl-lysine (CML) content were evaluated by fluorescence spectrophotometry and gas chromatography-mass spectrometry (GC-MS), respectively. The level of total fluorescent AGEs in seafood samples ranged from 39.37 to 1178.3 AU, and was higher in canned and packaged instant aquatic products that were processed at high temperatures. The CML content in seafood samples ranged from 44.8 to 439.1 mg per kg dried sample, and was higher in roasted seafood samples. The total fluorescent AGEs and CML content increased when seafood underwent high-temperature processing, but did not show an obvious correlation. The present study suggested that commonly consumed seafood contains different levels of AGEs, and the seafood processed at high temperatures always displays a high level of either AGEs or CML.
Lin, Meng Kuan; Nicolini, Oliver; Waxenegger, Harald; Galloway, Graham J; Ullmann, Jeremy F P; Janke, Andrew L
2013-01-01
Digital Imaging Processing (DIP) requires data extraction and output from a visualization tool to be consistent. Data handling and transmission between the server and a user is a systematic process in service interpretation. The use of integrated medical services for management and viewing of imaging data in combination with a mobile visualization tool can be greatly facilitated by data analysis and interpretation. This paper presents an integrated mobile application and DIP service, called M-DIP. The objective of the system is to (1) automate the direct data tiling, conversion, pre-tiling of brain images from Medical Imaging NetCDF (MINC), Neuroimaging Informatics Technology Initiative (NIFTI) to RAW formats; (2) speed up querying of imaging measurement; and (3) display high-level of images with three dimensions in real world coordinates. In addition, M-DIP provides the ability to work on a mobile or tablet device without any software installation using web-based protocols. M-DIP implements three levels of architecture with a relational middle-layer database, a stand-alone DIP server, and a mobile application logic middle level realizing user interpretation for direct querying and communication. This imaging software has the ability to display biological imaging data at multiple zoom levels and to increase its quality to meet users' expectations. Interpretation of bioimaging data is facilitated by an interface analogous to online mapping services using real world coordinate browsing. This allows mobile devices to display multiple datasets simultaneously from a remote site. M-DIP can be used as a measurement repository that can be accessed by any network environment, such as a portable mobile or tablet device. In addition, this system and combination with mobile applications are establishing a virtualization tool in the neuroinformatics field to speed interpretation services.
Lin, Meng Kuan; Nicolini, Oliver; Waxenegger, Harald; Galloway, Graham J.; Ullmann, Jeremy F. P.; Janke, Andrew L.
2013-01-01
Digital Imaging Processing (DIP) requires data extraction and output from a visualization tool to be consistent. Data handling and transmission between the server and a user is a systematic process in service interpretation. The use of integrated medical services for management and viewing of imaging data in combination with a mobile visualization tool can be greatly facilitated by data analysis and interpretation. This paper presents an integrated mobile application and DIP service, called M-DIP. The objective of the system is to (1) automate the direct data tiling, conversion, pre-tiling of brain images from Medical Imaging NetCDF (MINC), Neuroimaging Informatics Technology Initiative (NIFTI) to RAW formats; (2) speed up querying of imaging measurement; and (3) display high-level of images with three dimensions in real world coordinates. In addition, M-DIP provides the ability to work on a mobile or tablet device without any software installation using web-based protocols. M-DIP implements three levels of architecture with a relational middle-layer database, a stand-alone DIP server, and a mobile application logic middle level realizing user interpretation for direct querying and communication. This imaging software has the ability to display biological imaging data at multiple zoom levels and to increase its quality to meet users’ expectations. Interpretation of bioimaging data is facilitated by an interface analogous to online mapping services using real world coordinate browsing. This allows mobile devices to display multiple datasets simultaneously from a remote site. M-DIP can be used as a measurement repository that can be accessed by any network environment, such as a portable mobile or tablet device. In addition, this system and combination with mobile applications are establishing a virtualization tool in the neuroinformatics field to speed interpretation services. PMID:23847587
Transgenic mice overexpressing insulin-like growth factor-II in β cells develop type 2 diabetes
Devedjian, Jean-Christophe; George, Monica; Casellas, Alba; Pujol, Anna; Visa, Joana; Pelegrín, Mireia; Gros, Laurent; Bosch, Fatima
2000-01-01
During embryonic development, insulin-like growth factor-II (IGF-II) participates in the regulation of islet growth and differentiation. We generated transgenic mice (C57BL6/SJL) expressing IGF-II in β cells under control of the rat Insulin I promoter in order to study the role of islet hyperplasia and hyperinsulinemia in the development of type 2 diabetes. In contrast to islets from control mice, islets from transgenic mice displayed high levels of IGF-II mRNA and protein. Pancreases from transgenic mice showed an increase in β-cell mass (about 3-fold) and in insulin mRNA levels. However, the organization of cells within transgenic islets was disrupted, with glucagon-producing cells randomly distributed throughout the core. We also observed enhanced glucose-stimulated insulin secretion and glucose utilization in islets from transgenic mice. These mice displayed hyperinsulinemia, mild hyperglycemia, and altered glucose and insulin tolerance tests, and about 30% of these animals developed overt diabetes when fed a high-fat diet. Furthermore, transgenic mice obtained from the N1 backcross to C57KsJ mice showed high islet hyperplasia and insulin resistance, but they also developed fatty liver and obesity. These results indicate that local overexpression of IGF-II in islets might lead to type 2 diabetes and that islet hyperplasia and hypersecretion of insulin might occur early in the pathogenesis of this disease. PMID:10727441
Rogers, John A.; Bao, Zhenan; Baldwin, Kirk; Dodabalapur, Ananth; Crone, Brian; Raju, V. R.; Kuck, Valerie; Katz, Howard; Amundson, Karl; Ewing, Jay; Drzaic, Paul
2001-01-01
Electronic systems that use rugged lightweight plastics potentially offer attractive characteristics (low-cost processing, mechanical flexibility, large area coverage, etc.) that are not easily achieved with established silicon technologies. This paper summarizes work that demonstrates many of these characteristics in a realistic system: organic active matrix backplane circuits (256 transistors) for large (≈5 × 5-inch) mechanically flexible sheets of electronic paper, an emerging type of display. The success of this effort relies on new or improved processing techniques and materials for plastic electronics, including methods for (i) rubber stamping (microcontact printing) high-resolution (≈1 μm) circuits with low levels of defects and good registration over large areas, (ii) achieving low leakage with thin dielectrics deposited onto surfaces with relief, (iii) constructing high-performance organic transistors with bottom contact geometries, (iv) encapsulating these transistors, (v) depositing, in a repeatable way, organic semiconductors with uniform electrical characteristics over large areas, and (vi) low-temperature (≈100°C) annealing to increase the on/off ratios of the transistors and to improve the uniformity of their characteristics. The sophistication and flexibility of the patterning procedures, high level of integration on plastic substrates, large area coverage, and good performance of the transistors are all important features of this work. We successfully integrate these circuits with microencapsulated electrophoretic “inks” to form sheets of electronic paper. PMID:11320233
E-cigarette marketing in UK stores: an observational audit and retailers' views.
Eadie, D; Stead, M; MacKintosh, A M; MacDonald, L; Purves, R; Pearce, J; Tisch, C; van der Sluijis, W; Amos, A; MacGregor, A; Haw, S
2015-09-11
To explore how e-cigarettes are being promoted at point of sale in the UK and how retailers perceive market trends. Fixed retail outlets subject to a ban on the display of tobacco products. Observational audit of all stores selling tobacco products (n=96) in 4 Scottish communities, conducted over 2 waves 12 months apart (2013-2014), and qualitative interviews with small retailers (n=25) in 4 matched communities. The audit measured e-cigarette display characteristics, advertising materials and proximity to other products, and differences by area-level disadvantage. Interviews explored retailers' perceptions of e-cigarette market opportunities and risks, and customer responses. The number of e-cigarette point-of-sale display units and number of brands displayed increased between waves. E-cigarettes were displayed close to products of interest to children in 36% of stores. Stores in more affluent areas were less likely to have external e-cigarette advertising than those in deprived areas. Although e-cigarettes delivered high profit margins, retailers were confused by the diversity of brands and products, and uncertain of the sector's viability. Some customers were perceived to purchase e-cigarettes as cessation aids, and others, particularly low-income smokers, as a cheaper adjunct to conventional tobacco. E-cigarette point-of-sale displays and number of brands displayed increased over 12 months, a potential cause for concern given their lack of regulation. Further scrutiny is needed of the content and effects of such advertising, and the potentially normalising effects of placing e-cigarettes next to products of interest to children. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
E-cigarette marketing in UK stores: an observational audit and retailers’ views
Eadie, D; Stead, M; MacKintosh, A M; MacDonald, L; Purves, R; Pearce, J; Tisch, C; van der Sluijis, W; Amos, A; MacGregor, A; Haw, S
2015-01-01
Objectives To explore how e-cigarettes are being promoted at point of sale in the UK and how retailers perceive market trends. Setting Fixed retail outlets subject to a ban on the display of tobacco products. Participants Observational audit of all stores selling tobacco products (n=96) in 4 Scottish communities, conducted over 2 waves 12 months apart (2013–2014), and qualitative interviews with small retailers (n=25) in 4 matched communities. Primary and secondary outcome measures The audit measured e-cigarette display characteristics, advertising materials and proximity to other products, and differences by area-level disadvantage. Interviews explored retailers’ perceptions of e-cigarette market opportunities and risks, and customer responses. Results The number of e-cigarette point-of-sale display units and number of brands displayed increased between waves. E-cigarettes were displayed close to products of interest to children in 36% of stores. Stores in more affluent areas were less likely to have external e-cigarette advertising than those in deprived areas. Although e-cigarettes delivered high profit margins, retailers were confused by the diversity of brands and products, and uncertain of the sector's viability. Some customers were perceived to purchase e-cigarettes as cessation aids, and others, particularly low-income smokers, as a cheaper adjunct to conventional tobacco. Conclusions E-cigarette point-of-sale displays and number of brands displayed increased over 12 months, a potential cause for concern given their lack of regulation. Further scrutiny is needed of the content and effects of such advertising, and the potentially normalising effects of placing e-cigarettes next to products of interest to children. PMID:26362665
Flexible high-resolution display systems for the next generation of radiology reading rooms
NASA Astrophysics Data System (ADS)
Caban, Jesus J.; Wood, Bradford J.; Park, Adrian
2007-03-01
A flexible, scalable, high-resolution display system is presented to support the next generation of radiology reading rooms or interventional radiology suites. The project aims to create an environment for radiologists that will simultaneously facilitate image interpretation, analysis, and understanding while lowering visual and cognitive stress. Displays currently in use present radiologists with technical challenges to exploring complex datasets that we seek to address. These include resolution and brightness, display and ambient lighting differences, and degrees of complexity in addition to side-by-side comparison of time-variant and 2D/3D images. We address these issues through a scalable projector-based system that uses our custom-designed geometrical and photometrical calibration process to create a seamless, bright, high-resolution display environment that can reduce the visual fatigue commonly experienced by radiologists. The system we have designed uses an array of casually aligned projectors to cooperatively increase overall resolution and brightness. Images from a set of projectors in their narrowest zoom are combined at a shared projection surface, thus increasing the global "pixels per inch" (PPI) of the display environment. Two primary challenges - geometric calibration and photometric calibration - remained to be resolved before our high-resolution display system could be used in a radiology reading room or procedure suite. In this paper we present a method that accomplishes those calibrations and creates a flexible high-resolution display environment that appears seamless, sharp, and uniform across different devices.
Varela, M Celeste; Reinoso, Herminda; Luna, Virginia; Cenzano, Ana M
2018-06-01
In semi-arid regions, plants develop various biochemical and physiological strategies to adapt to dry periods. Understanding the resistance mechanisms to dry periods under field conditions is an important topic in ecology. Larrea divaricata and Lycium chilense provide various ecological services. The aim of this work is to elucidate new morpho-histological, biochemical and hormonal traits that contribute to the drought resistance strategies of two native shrubs. Green leaves and fine roots from L. divaricata and L. chilense were collected in each season for one year, and various traits were measured. The hormone (abscisic acid, ABA-glucose ester, gibberellins A 1 and A 3 , and indole acetic acid) contents were determined by liquid chromatography coupled to mass spectrometry. Rainfall data and the soil water content were also measured. A multivariate analysis showed that green leaves from L. divaricata showed high values for the leaf dry weight, blade leaf thickness and ABA content in the summer compared with those from L. chilense. Fine roots from L. divaricata had high RWC and high IAA levels during the autumn-dry period compared with those from L. chilense, but both had similar levels during the winter and spring. Our results support the notion that species with different drought resistance mechanisms (avoidance or tolerance) display different responses to dry periods throughout the year. Larrea divaricata, which exhibits more xerophytic traits, modified its morphology and maintained its physiological parameters (high RWC in leaves and roots, high ABA levels in leaves during summer, high GA 3 in leaves and high IAA in roots during autumn) to tolerate dry periods, whereas Lycium chilense, which displays more mesophytic traits, uses strategies to avoid dry periods (loss of leaves during autumn and winter, high RWC in leaves, high ABA-GE and GA 3 in leaves during summer, high GA 1 and GA 3 in roots during summer, and high IAA in roots during autumn and summer) and thus has a metabolism that is more dependent on water availability for growth. Copyright © 2018. Published by Elsevier Masson SAS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradel, Lauren; Endert, Alexander; Koch, Kristen
2013-08-01
Large, high-resolution vertical displays carry the potential to increase the accuracy of collaborative sensemaking, given correctly designed visual analytics tools. From an exploratory user study using a fictional textual intelligence analysis task, we investigated how users interact with the display to construct spatial schemas and externalize information, as well as how they establish shared and private territories. We investigated the space management strategies of users partitioned by type of tool philosophy followed (visualization- or text-centric). We classified the types of territorial behavior exhibited in terms of how the users interacted with information on the display (integrated or independent workspaces). Next,more » we examined how territorial behavior impacted the common ground between the pairs of users. Finally, we offer design suggestions for building future co-located collaborative visual analytics tools specifically for use on large, high-resolution vertical displays.« less
Perception of Social Interactions for Spatially Scrambled Biological Motion
Thurman, Steven M.; Lu, Hongjing
2014-01-01
It is vitally important for humans to detect living creatures in the environment and to analyze their behavior to facilitate action understanding and high-level social inference. The current study employed naturalistic point-light animations to examine the ability of human observers to spontaneously identify and discriminate socially interactive behaviors between two human agents. Specifically, we investigated the importance of global body form, intrinsic joint movements, extrinsic whole-body movements, and critically, the congruency between intrinsic and extrinsic motions. Motion congruency is hypothesized to be particularly important because of the constraint it imposes on naturalistic action due to the inherent causal relationship between limb movements and whole body motion. Using a free response paradigm in Experiment 1, we discovered that many naïve observers (55%) spontaneously attributed animate and/or social traits to spatially-scrambled displays of interpersonal interaction. Total stimulus motion energy was strongly correlated with the likelihood that an observer would attribute animate/social traits, as opposed to physical/mechanical traits, to the scrambled dot stimuli. In Experiment 2, we found that participants could identify interactions between spatially-scrambled displays of human dance as long as congruency was maintained between intrinsic/extrinsic movements. Violating the motion congruency constraint resulted in chance discrimination performance for the spatially-scrambled displays. Finally, Experiment 3 showed that scrambled point-light dancing animations violating this constraint were also rated as significantly less interactive than animations with congruent intrinsic/extrinsic motion. These results demonstrate the importance of intrinsic/extrinsic motion congruency for biological motion analysis, and support a theoretical framework in which early visual filters help to detect animate agents in the environment based on several fundamental constraints. Only after satisfying these basic constraints could stimuli be evaluated for high-level social content. In this way, we posit that perceptual animacy may serve as a gateway to higher-level processes that support action understanding and social inference. PMID:25406075
Evaluating Approaches to Rendering Braille Text on a High-Density Pin Display.
Morash, Valerie S; Russomanno, Alexander; Gillespie, R Brent; OModhrain, Sile
2017-10-13
Refreshable displays for tactile graphics are typically composed of pins that have smaller diameters and spacing than standard braille dots. We investigated configurations of high-density pins to form braille text on such displays using non-refreshable stimuli produced with a 3D printer. Normal dot braille (diameter 1.5 mm) was compared to high-density dot braille (diameter 0.75 mm) wherein each normal dot was rendered by high-density simulated pins alone or in a cluster of pins configured in a diamond, X, or square; and to "blobs" that could result from covering normal braille and high-density multi-pin configurations with a thin membrane. Twelve blind participants read MNREAD sentences displayed in these conditions. For high-density simulated pins, single pins were as quickly and easily read as normal braille, but diamond, X, and square multi-pin configurations were slower and/or harder to read than normal braille. We therefore conclude that as long as center-to-center dot spacing and dot placement is maintained, the dot diameter may be open to variability for rendering braille on a high density tactile display.
Christoforou, Paraskevi S; Ashforth, Blake E
2015-01-01
We argue that the strength with which the organization communicates expectations regarding the appropriate emotional expression toward customers (i.e., explicitness of display rules) has an inverted U-shaped relationship with service delivery behaviors, customer satisfaction, and sales performance. Further, we argue that service organizations need a particular blend of explicitness of display rules and role discretion for the purpose of optimizing sales performance. As hypothesized, findings from 2 samples of salespeople suggest that either high or low explicitness of display rules impedes service delivery behaviors and sales performance, which peaks at moderate explicitness of display rules and high role discretion. The findings also suggest that the explicitness of display rules has a positive relationship with customer satisfaction. (c) 2015 APA, all rights reserved.
An Electronic Pressure Profile Display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPI) unit which interfaces with a host computer. The host computer collects the pressure data from the DPI unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
An electronic pressure profile display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPT) unit which interfaces with a host computer. The host computer collects the pressure data from the DPT unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
Sanga, Ramesh; Agarwal, Sourabh; Sivaramakrishna, M; Rao, G Prabhakara
2018-04-01
Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.
NASA Astrophysics Data System (ADS)
Sanga, Ramesh; Agarwal, Sourabh; Sivaramakrishna, M.; Rao, G. Prabhakara
2018-04-01
Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ˜2.5 kHz/mm.
Somers, Klaartje; Stinissen, Piet; Somers, Veerle
2011-06-01
Phage display is a high-throughput technology used to identify ligands for a given target. A drawback of the approach is the absence of PTMs in phage-displayed peptides. The applicability of phage display could be broadened considerably by the implementation of PTMs in this system. The aim of this study was to investigate the possible application of citrullination, a PTM of an arginine into a citrulline amino acid, in filamentous (M13) and lytic (T7) phage display. After in vitro citrullination of T7 and M13 phages, citrullination was confirmed and the infectivity of both citrullinated and non-citrullinated phage was compared by titer determination. We demonstrated the successful in vitro citrullination of T7 and M13 phage-displayed peptides. This in vitro modification did not affect the viability or infectivity of the T7 virions, a necessary prerequisite for the implementation of this approach in T7 phage display. For M13 phage, however, the infecting phage titer decreased five-fold upon citrullination, limiting the use of this modification in M13 phage display. In conclusion, in vitro citrullination can be applied in T7 phage display giving rise to a high-throughput and sensitive approach to identify citrulline-containing ligands by the use of the strengths of phage display technology. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Progress of OLED devices with high efficiency at high luminance
NASA Astrophysics Data System (ADS)
Nguyen, Carmen; Ingram, Grayson; Lu, Zhenghong
2014-03-01
Organic light emitting diodes (OLEDs) have progressed significantly over the last two decades. For years, OLEDs have been promoted as the next generation technology for flat panel displays and solid-state lighting due to their potential for high energy efficiency and dynamic range of colors. Although high efficiency can readily be obtained at low brightness levels, a significant decline at high brightness is commonly observed. In this report, we will review various strategies for achieving highly efficient phosphorescent OLED devices at high luminance. Specifically, we will provide details regarding the performance and general working principles behind each strategy. We will conclude by looking at how some of these strategies can be combined to produce high efficiency white OLEDs at high brightness.
Heath, Wendy P
2009-01-01
Research from both simulated and actual jurors has demonstrated that the defendant's emotional display can influence legal decisions. The purpose of this paper is to review the evidence regarding the influence of the defendant's emotional display, and to consider the potential role of suspect and defendant emotion in wrongful convictions. It is possible that the lack of "appropriate" emotion during questioning or interrogation may lead investigators to create a mind-set that the suspect is the guilty party; as a result, they may be less inclined to investigate other leads. During a trial, the defendant's perceived level of emotion can potentially mislead jurors (e.g. a defendant displaying a low level of emotion leading people to believe, inappropriately, that he is guilty). After a review of the pertinent literature and examples of relevant cases, reasons are provided regarding why one's emotional display may be of limited diagnostic value. Future research ideas are proposed in an effort to determine more definitively the impact of the emotional display of the accused on legal decisions. (c) 2009 John Wiley & Sons, Ltd.
On The Influence Of Vector Design On Antibody Phage Display
Soltes, Glenn; Hust, Michael; Ng, Kitty K.Y.; Bansal, Aasthaa; Field, Johnathan; Stewart, Donald I.H.; Dübel, Stefan; Cha, Sanghoon; Wiersma, Erik J
2007-01-01
Phage display technology is an established technology particularly useful for the generation of monoclonal antibodies (mAbs). The isolation of phagemid-encoded mAb fragments depends on several features of a phage preparation. The aims of this study were to optimize phage display vectors, and to ascertain if different virion features can be optimized independently of each other. Comparisons were made between phagemid virions assembled by g3p-deficient helper phage, Hyperphage, Ex-phage or Phaberge, or corresponding g3p-sufficient helper phage, M13K07. All g3p-deficient helper phage provided a similar level of antibody display, significantly higher than that of M13K07. Hyperphage packaged virions at least 100-fold more efficiently than did Ex-phage or Phaberge. Phaberge's packaging efficiency improved by using a SupE strain. Different phagemids were also compared. Removal of a 56 base pair fragment from the promoter region resulted in increased display level and increased virion production. This critical fragment encodes a lacZ'-like peptide and is also present in other commonly used phagemids. Increasing display level did not show statistical correlation with phage production, phage infectivity or bacterial growth rate. However, phage production was positively correlated to phage infectivity. In summary, this study demonstrates simultaneously optimization of multiple and independent features of importance for phage selection. PMID:16996161
On the influence of vector design on antibody phage display.
Soltes, Glenn; Hust, Michael; Ng, Kitty K Y; Bansal, Aasthaa; Field, Johnathan; Stewart, Donald I H; Dübel, Stefan; Cha, Sanghoon; Wiersma, Erik J
2007-01-20
Phage display technology is an established technology particularly useful for the generation of monoclonal antibodies (mAbs). The isolation of phagemid-encoded mAb fragments depends on several features of a phage preparation. The aims of this study were to optimize phage display vectors, and to ascertain if different virion features can be optimized independently of each other. Comparisons were made between phagemid virions assembled by g3p-deficient helper phage, Hyperphage, Ex-phage or Phaberge, or corresponding g3p-sufficient helper phage, M13K07. All g3p-deficient helper phage provided a similar level of antibody display, significantly higher than that of M13K07. Hyperphage packaged virions at least 100-fold more efficiently than did Ex-phage or Phaberge. Phaberge's packaging efficiency improved by using a SupE strain. Different phagemids were also compared. Removal of a 56 base pair fragment from the promoter region resulted in increased display level and increased virion production. This critical fragment encodes a lacZ'-like peptide and is also present in other commonly used phagemids. Increasing display level did not show statistical correlation with phage production, phage infectivity or bacterial growth rate. However, phage production was positively correlated to phage infectivity. In summary, this study demonstrates simultaneously optimization of multiple and independent features of importance for phage selection.
Item Analysis and Differential Item Functioning of a Brief Conduct Problem Screen
ERIC Educational Resources Information Center
Wu, Johnny; King, Kevin M.; Witkiewitz, Katie; Racz, Sarah Jensen; McMahon, Robert J.
2012-01-01
Research has shown that boys display higher levels of childhood conduct problems than girls, and Black children display higher levels than White children, but few studies have tested for scalar equivalence of conduct problems across gender and race. The authors conducted a 2-parameter item response theory (IRT) model to examine item…
Motmot, an open-source toolkit for realtime video acquisition and analysis.
Straw, Andrew D; Dickinson, Michael H
2009-07-22
Video cameras sense passively from a distance, offer a rich information stream, and provide intuitively meaningful raw data. Camera-based imaging has thus proven critical for many advances in neuroscience and biology, with applications ranging from cellular imaging of fluorescent dyes to tracking of whole-animal behavior at ecologically relevant spatial scales. Here we present 'Motmot': an open-source software suite for acquiring, displaying, saving, and analyzing digital video in real-time. At the highest level, Motmot is written in the Python computer language. The large amounts of data produced by digital cameras are handled by low-level, optimized functions, usually written in C. This high-level/low-level partitioning and use of select external libraries allow Motmot, with only modest complexity, to perform well as a core technology for many high-performance imaging tasks. In its current form, Motmot allows for: (1) image acquisition from a variety of camera interfaces (package motmot.cam_iface), (2) the display of these images with minimal latency and computer resources using wxPython and OpenGL (package motmot.wxglvideo), (3) saving images with no compression in a single-pass, low-CPU-use format (package motmot.FlyMovieFormat), (4) a pluggable framework for custom analysis of images in realtime and (5) firmware for an inexpensive USB device to synchronize image acquisition across multiple cameras, with analog input, or with other hardware devices (package motmot.fview_ext_trig). These capabilities are brought together in a graphical user interface, called 'FView', allowing an end user to easily view and save digital video without writing any code. One plugin for FView, 'FlyTrax', which tracks the movement of fruit flies in real-time, is included with Motmot, and is described to illustrate the capabilities of FView. Motmot enables realtime image processing and display using the Python computer language. In addition to the provided complete applications, the architecture allows the user to write relatively simple plugins, which can accomplish a variety of computer vision tasks and be integrated within larger software systems. The software is available at http://code.astraw.com/projects/motmot.
NASA Astrophysics Data System (ADS)
Rochette, Rémy; Dunmall, Karen; Dill, Lawrence M.
2003-03-01
On wave-sheltered shores of the northeastern Pacific, the population size structure of Littorina sitkana varies with intertidal height, as larger snails are mostly found only in the upper intertidal. This pattern has been attributed to high predation rates by crabs (and perhaps fish) on large snails inhabiting low-intertidal areas; i.e., large snails are presumed to be rare there simply because predators kill them. In this study we investigate the hypothesis that predation contributes to the shore-level size gradient displayed by L. sitkana by selecting for (or inducing) earlier sexual maturation and reduced somatic growth in low-shore snails relative to high-shore individuals. In the first part of our study, we carried out laboratory dissections, field experiments (mark-release-recapture and caging), and field surveys on a wave-protected shore in Bamfield Inlet, Barkley Sound (British Columbia, Canada). The principal results were: (1) adult survivorship was greater at higher, than at lower, intertidal level, (2) snails displayed a preference for their shore level of origin, (3) immature adults from the high intertidal displayed greater rates of somatic growth relative to immature adults from the low intertidal, and (4) low-shore snails matured at a smaller size than high-shore individuals. In the second part of the study, a large-scale survey showed intra-specific variation in size at sexual maturity (point 4 above) to be relatively consistent over time (winter of 1999 and 2001 for snails from our main study site) and space (13 different sites in winter 2001), although the magnitude of these differences varied greatly from shore to shore. Our results indicate that L. sitkana individuals inhabiting upper and lower parts of their intertidal range allocate resources differently to somatic and gonadal growth, an intra-specific difference that is best interpreted as a response to spatial and size-dependent variation in predation pressure. Taken together, results of this and other recent studies indicate that phenotypic responses to contrasting selection pressures operating in upper- and lower-intertidal areas contribute to the intertidal size gradient of L. sitkana. We believe that greater consideration of evolutionary processes in ecological studies will lead to a more complete understanding of the mechanisms responsible for structuring marine coastal communities.
Promotion of Cancer Stem-Like Cell Properties in Hepatitis C Virus-Infected Hepatocytes
Kwon, Young-Chan; Bose, Sandip K.; Steele, Robert; Meyer, Keith; Di Bisceglie, Adrian M.; Ray, Ratna B.
2015-01-01
ABSTRACT We have previously reported that hepatitis C virus (HCV) infection of primary human hepatocytes (PHH) induces the epithelial mesenchymal transition (EMT) state and extends hepatocyte life span (S. K. Bose, K. Meyer, A. M. Di Bisceglie, R. B. Ray, and R. Ray, J Virol 86:13621–13628, 2012, http://dx.doi.org/10.1128/JVI.02016-12). These hepatocytes displayed sphere formation on ultralow binding plates and survived for more than 12 weeks. The sphere-forming hepatocytes expressed a number of cancer stem-like cell (CSC) markers, including high levels of the stem cell factor receptor c-Kit. The c-Kit receptor is regarded as one of the CSC markers in hepatocellular carcinoma (HCC). Analysis of c-Kit mRNA displayed a significant increase in the liver biopsy specimens of chronically HCV-infected patients. We also found c-Kit is highly expressed in transformed human hepatocytes (THH) infected in vitro with cell culture-grown HCV genotype 2a. Further studies suggested that HCV core protein significantly upregulates c-Kit expression at the transcriptional level. HCV infection of THH led to a significant increase in the number of spheres displayed on ultralow binding plates and in enhanced EMT and CSC markers and tumor growth in immunodeficient mice. The use of imatinib or dasatinib as a c-Kit inhibitor reduced the level of sphere-forming cells in culture. The sphere-forming cells were sensitive to treatment with sorafenib, a multikinase inhibitor, that is used for HCC treatment. Further, stattic, an inhibitor of the Stat3 molecule, induced sphere-forming cell death. A combination of sorafenib and stattic had a significantly stronger effect, leading to cell death. These results suggested that HCV infection potentiates CSC generation, and selected drugs can be targeted to efficiently inhibit cell growth. IMPORTANCE HCV infection may develop into HCC as an end-stage liver disease. We focused on understanding the mechanism for the risk of HCC from chronic HCV infection and identified targets for treatment. HCV-infected primary and transformed human hepatocytes (PHH or THH) generated CSC. HCV-induced spheres were highly sensitive to cell death from sorafenib and stattic treatment. Thus, our study is highly significant for HCV-associated HCC, with the potential for developing a target-specific strategy for improved therapies. PMID:26355082
Evolution of Src Homology 2 (SH2) Domain to Recognize Sulfotyrosine.
Ju, Tong; Niu, Wei; Guo, Jiantao
2016-09-16
Protein tyrosine O-sulfation is considered as the most common type of post-translational tyrosine modification in nature and plays important roles in extracellular biomolecular interactions. To facilitate the mapping, biological study, and medicinal application of this type of post-translational modification, we seek to evolve a small protein scaffold that recognizes sulfotyrosine with high affinity. We focused our efforts on the engineering of the Src Homology 2 (SH2) domain, which represents the largest class of known phosphotyrosine-recognition domain in nature and has a highly evolvable binding pocket. By using phage display, we successfully engineered the SH2 domain to recognize sulfotyrosine with high affinity. The best mutant, SH2-60.1, displayed more than 1700 fold higher sulfotyrosine-binding affinity than that of the wild-type SH2 domain. We also demonstrated that the evolved SH2 domain mutants could be used to detect sulfoprotein levels on the cell surface. These evolved SH2 domain mutants can be potentially applied to the study of protein tyrosine O-sulfation with proper experimental designs.
Ruttle, Paula L; Armstrong, Jeffrey M; Klein, Marjorie H; Essex, Marilyn J
2014-11-01
Although adolescence is marked by increased negative life events and internalizing problems, few studies investigate this association as an ongoing longitudinal process. Moreover, while there are considerable individual differences in the degree to which these phenomena are linked, little is known about the origins of these differences. The present study examines early life stress (ELS) exposure and early-adolescent longitudinal afternoon cortisol level as predictors of the covariation between internalizing symptoms and negative life events across high school. ELS was assessed by maternal report during infancy, and the measure of cortisol was derived from assessments at ages 11, 13, and 15 years. Life events and internalizing symptoms were assessed at ages 15, 17, and 18 years. A two-level hierarchical linear model revealed that ELS and cortisol were independent predictors of the covariation of internalizing symptoms and negative life events. Compared to those with lower levels of ELS, ELS-exposed adolescents displayed tighter covariation between internalizing symptoms and negative life events. Adolescents with lower longitudinal afternoon cortisol displayed tighter covariation between negative life events and internalizing symptoms, while those with higher cortisol demonstrated weaker covariation, partially due to increased levels of internalizing symptoms when faced with fewer negative life events.
Iconic memory requires attention
Persuh, Marjan; Genzer, Boris; Melara, Robert D.
2012-01-01
Two experiments investigated whether attention plays a role in iconic memory, employing either a change detection paradigm (Experiment 1) or a partial-report paradigm (Experiment 2). In each experiment, attention was taxed during initial display presentation, focusing the manipulation on consolidation of information into iconic memory, prior to transfer into working memory. Observers were able to maintain high levels of performance (accuracy of change detection or categorization) even when concurrently performing an easy visual search task (low load). However, when the concurrent search was made difficult (high load), observers' performance dropped to almost chance levels, while search accuracy held at single-task levels. The effects of attentional load remained the same across paradigms. The results suggest that, without attention, participants consolidate in iconic memory only gross representations of the visual scene, information too impoverished for successful detection of perceptual change or categorization of features. PMID:22586389
Iconic memory requires attention.
Persuh, Marjan; Genzer, Boris; Melara, Robert D
2012-01-01
Two experiments investigated whether attention plays a role in iconic memory, employing either a change detection paradigm (Experiment 1) or a partial-report paradigm (Experiment 2). In each experiment, attention was taxed during initial display presentation, focusing the manipulation on consolidation of information into iconic memory, prior to transfer into working memory. Observers were able to maintain high levels of performance (accuracy of change detection or categorization) even when concurrently performing an easy visual search task (low load). However, when the concurrent search was made difficult (high load), observers' performance dropped to almost chance levels, while search accuracy held at single-task levels. The effects of attentional load remained the same across paradigms. The results suggest that, without attention, participants consolidate in iconic memory only gross representations of the visual scene, information too impoverished for successful detection of perceptual change or categorization of features.
Advance in phage display technology for bioanalysis.
Tan, Yuyu; Tian, Tian; Liu, Wenli; Zhu, Zhi; J Yang, Chaoyong
2016-06-01
Phage display technology has emerged as a powerful tool for target gene expression and target-specific ligand selection. It is widely used to screen peptides, proteins and antibodies with the advantages of simplicity, high efficiency and low cost. A variety of targets, including ions, small molecules, inorganic materials, natural and biological polymers, nanostructures, cells, bacteria, and even tissues, have been demonstrated to generate specific binding ligands by phage display. Phages and target-specific ligands screened by phage display have been widely used as affinity reagents in therapeutics, diagnostics and biosensors. In this review, comparisons of different types of phage display systems are first presented. Particularly, microfluidic-based phage display, which enables screening with high throughput, high efficiency and integration, is highlighted. More importantly, we emphasize the advances in biosensors based on phages or phage-derived probes, including nonlytic phages, lytic phages, peptides or proteins screened by phage display, phage assemblies and phage-nanomaterial complexes. However, more efficient and higher throughput phage display methods are still needed to meet an explosion in demand for bioanalysis. Furthermore, screening of cyclic peptides and functional peptides will be the hotspot in bioanalysis. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
High-performance 4x4-inch AMLCD for avionic applications
NASA Astrophysics Data System (ADS)
Syroid, Daniel D.; Hansen, Glenn A.; Boling, Ed
1996-05-01
There is a need for high performance flat panel displays to replace and upgrade the electromechanical flight indicators and CRT based displays used in the cockpits of many older aircraft that are in active service today. The need for replacement of these older generation instruments is well known in the industry and was discussed in a previous paper by Duane Grave of Rockwell Collins. Furthermore, because of the limited activity in new aircraft development today, the need to upgrade existing aircraft avionics is accelerating. Many of the electromechanical instruments currently provide flight indications to the pilot and include horizontal situation (HSI) and attitude director indicators (ADI). These instruments are used on both military and commercial aircraft. The indicators are typically housed in a 5ATI case that slides into a 5 inch square opening in the cockpit. Image Quest has developed a 4 by 4 inch active area, flight quality, high resolution, full color, high luminance, wide temperature range display module based on active matrix liquid crystal display (AMLCD) technology that has excellent contrast in full sunlight. The display module is well suited for use in electronic instruments to replace or upgrade the electro-mechanical 5ATI flight indicators. THe AMLCD based display offers greatly improved display format flexibility, operating reliability and display contrast in all ambient lighting conditions as well as significant short and long term cost of ownership advantages.
Thomas, Lisa C; Wickens, Christopher D
2008-08-01
Two experiments explored the effects of display dimensionality, conflict geometry, and time pressure on pilot maneuvering preferences for resolving en route conflicts. With the presence of a cockpit display of traffic information (CDTI) that provides graphical airspace information, pilots can use a variety of conflict resolution maneuvers in response to how they perceive the conflict. Inconsistent preference findings from previous research on conflict resolution using CDTIs may be attributable to inherent ambiguities in 3-D perspective displays and/or a limited range of conflict geometries. Pilots resolved predicted conflicts using CDTIs with three levels of display dimensionality; the first had two 2-D orthogonal views, the second depicted the airspace in two alternating 3-D perspective views, and the third had a pilot-controlled swiveling viewpoint. Pilots demonstrated the same preferences that have been observed in previous research for vertical over lateral maneuvers in low workload and climbs over descents for level-flight conflicts. With increasing workload the two 3-D perspective displays, but not the 2-D displays, resulted in an increased preference for lateral over vertical maneuvers. Increased time pressure resulted in increased vertical maneuvers, an effect again limited to the two 3-D perspective displays. Resolution preferences were more affected by workload and time pressure when the 3-D perspective displays were used, as compared with the 2-D displays, although overall preferences were milder than in previous studies. Investigating maneuver preferences using the strategic flight planning paradigm employed in this study may be the key to better ensure pilot acceptance of computer-generated resolution maneuvers.
Li, Hong-Mei; Guo, Kang; Yu, Zhuang; Feng, Rui; Xu, Ping
2015-07-01
Traditional diagnostic technology with tumor biomarkers is inefficient, expensive and requires a large number of serum samples. The purpose of this study was to construct human lung cancer protein chips with new lung cancer biomarkers screened by the T7-phage display library, and improve the early diagnosis rate of lung cancer. A T7-phage cDNA display library was constructed of fresh samples from 30 lung cancer patients. With biopanning and high-throughput screening, we gained the immunogenic phage clones from the cDNA library. The insert of selected phage was blasted at GeneBank for alignment to find the exact or the most similar known genes. Protein chips were then constructed and used to assay their expression level in lung cancer serum from 217 cases of lung cancer groups:80 cases of benign lung disease and 220 healthy controls. After four rounds of Biopanning and two rounds of enzyme-linked immunosorbent assay, 12 phage monoclonal samples were selected from 2880 phage monoclonal samples. After blasting at GeneBank, six similar genes were used to construct diagnostic protein chips. The protein chips were then used to assay expression level in lung cancer serum. The expression level of six genes in lung cancer groups was significantly higher than those in the other two groups (P < 0.05). In this study, we successfully constructed diagnostic protein chips with biomarkers selected from the lung cancer T7-phage cDNA library, which can be used for the early screening of lung cancer patients.
Tong, Xin; Gromala, Diane; Gupta, Dimple; Squire, Pam
2016-01-01
Researchers have shown that immersive Virtual Reality (VR) can serve as an unusually powerful pain control technique. However, research assessing the reported symptoms and negative effects of VR systems indicate that it is important to ascertain if these symptoms arise from the use of particular VR display devices, particularly for users who are deemed "at risk," such as chronic pain patients Moreover, these patients have specific and often complex needs and requirements, and because basic issues such as 'comfort' may trigger anxiety or panic attacks, it is important to examine basic questions of the feasibility of using VR displays. Therefore, this repeated-measured experiment was conducted with two VR displays: the Oculus Rift's head-mounted display (HMD) and Firsthand Technologies' immersive desktop display, DeepStream3D. The characteristics of these immersive desktop displays differ: one is worn, enabling patients to move their heads, while the other is peered into, allowing less head movement. To assess the severity of physical discomforts, 20 chronic pain patients tried both displays while watching a VR pain management demo in clinical settings. Results indicated that participants experienced higher levels of Simulator Sickness using the Oculus Rift HMD. However, results also indicated other preferences of the two VR displays among patients, including physical comfort levels and a sense of immersion. Few studies have been conducted that compare usability of specific VR devices specifically with chronic pain patients using a therapeutic virtual environment in pain clinics. Thus, the results may help clinicians and researchers to choose the most appropriate VR displays for chronic pain patients and guide VR designers to enhance the usability of VR displays for long-term pain management interventions.
Yang, Tao; Yang, Lijun; Chai, Weiran; Li, Renke; Xie, Jun; Niu, Bo
2011-03-01
A phage display single-chain variable fragment (scFv) library against TNFα was constructed using a recombinant phage antibody system (RPAS). The cloned scFv gene was introduced into the phage display vector pCANTAB 5E and expressed in Escherichia coli (E. coli) with a yield of up to 0.15 mg/l of total protein. With the attempt to improve the expression level of TNF-scFv, a strategy was established for subcloning the scFv gene from pCANTAB 5E into the plasmid pBV220. Under the control of a highly efficient tandem P(R)P(L) promoter system, scFv production was increased to 30% of total protein as inclusion bodies. After extraction from the cell pellet by sonication, the inclusion bodies were solubilized and denatured in the presence of 8M urea. Purification of denatured scFv was performed using nickel column chromatography followed by renaturation. The purity and activity of the refolded scFv were confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), Western blotting and by an enzyme-linked immunoabsorbent assay (ELISA). The results reveal that the overall yield of bioactive TNF-scFv from E. coli flask cultures was more than 45 mg/l culture medium and 15 mg/g wet weight cells. The renatured scFv exhibited binding activity similarly to soluble scFv. In conclusion we developed a method to over-express TNF-scFv, which have biological function after purification and renaturation. Copyright © 2010 Elsevier Inc. All rights reserved.
Hewlett-Packard's Approaches to Full Color Reflective Displays
NASA Astrophysics Data System (ADS)
Gibson, Gary
2012-02-01
Reflective displays are desirable in applications requiring low power or daylight readability. However, commercial reflective displays are currently either monochrome or capable of only dim color gamuts. Low cost, high-quality color technology would be rapidly adopted in existing reflective display markets and would enable new solutions in areas such as retail pricing and outdoor digital signage. Technical breakthroughs are required to enable bright color gamuts at reasonable cost. Pixel architectures that rely on pure reflection from a single layer of side-by-side primary-color sub-pixels use only a fraction of the display area to reflect incident light of a given color and are, therefore, unacceptably dark. Reflective devices employing stacked color primaries offer the possibility of a somewhat brighter color gamut but can be more complex to manufacture. In this talk, we describe HP's successes in addressing these fundamental challenges and creating both high performance stacked-primary reflective color displays as well as inexpensive single layer prototypes that provide good color. Our stacked displays utilize a combination of careful light management techniques, proprietary high-contrast electro-optic shutters, and highly transparent active-matrix TFT arrays based on transparent metal oxides. They also offer the possibility of relatively low cost manufacturing through roll-to-roll processing on plastic webs. To create even lower cost color displays with acceptable brightness, we have developed means for utilizing photoluminescence to make more efficient use of ambient light in a single layer device. Existing reflective displays create a desired color by reflecting a portion of the incident spectrum while absorbing undesired wavelengths. We have developed methods for converting the otherwise-wasted absorbed light to desired wavelengths via tailored photoluminescent composites. Here we describe a single active layer prototype display that utilizes these materials along with an innovative optical out-coupling scheme. Further benefits of our approach include means for highly power-efficient back-lighting under low ambient light conditions and the possibility of video rate operation.
NASA Technical Reports Server (NTRS)
Kornilova, L. N.; Cowings, P. S.; Toscano, W. B.; Arlashchenko, N. I.; Korneev, D. Iu; Ponomarenko, A. V.; Salagovich, S. V.; Sarantseva, A. V.; Kozlovskaia, I. B.
2000-01-01
Presented are results of testing the method of adaptive biocontrol during preflight training of cosmonauts. Within the MIR-25 crew, a high level of controllability of the autonomous reactions was characteristic of Flight Commanders MIR-23 and MIR-25 and flight Engineer MIR-23, while Flight Engineer MIR-25 displayed a weak intricate dependence of these reactions on the depth of relaxation or strain.
Leon, Jaime; Medina-Garrido, Elena; Núñez, Juan L.
2017-01-01
Math achievement and engagement declines in secondary education; therefore, educators are faced with the challenge of engaging students to avoid school failure. Within self-determination theory, we address the need to assess comprehensively student perceptions of teaching quality that predict engagement and achievement. In study one we tested, in a sample of 548 high school students, a preliminary version of a scale to assess nine factors: teaching for relevance, acknowledge negative feelings, participation encouragement, controlling language, optimal challenge, focus on the process, class structure, positive feedback, and caring. In the second study, we analyzed the scale’s reliability and validity in a sample of 1555 high school students. The scale showed evidence of reliability, and with regard to criterion validity, at the classroom level, teaching quality was a predictor of behavioral engagement, and higher grades were observed in classes where students, as a whole, displayed more behavioral engagement. At the within level, behavioral engagement was associated with achievement. We not only provide a reliable and valid method to assess teaching quality, but also a method to design interventions, these could be designed based on the scale items to encourage students to persist and display more engagement on school duties, which in turn bolsters student achievement. PMID:28701964
Taladriz, Soraya; Hanke, Tobias; Ramiro, María J.; García-Díaz, Miguel; Lacoba, Mario García de; Blanco, Luis; Larraga, Vicente
2001-01-01
We have identified a novel polymerase beta (Pol β)-like enzyme from Leishmania infantum, a parasite protozoon causing disease in humans. This protein, named Li Pol β, shows a nuclear localization that contrasts with the mitochondrial localization of Pol β from Crithidia fasciculata, a closely related parasite, the only polymerase β described so far in Trypanosomatidae. Li Pol β, that belongs to the DNA polymerase X family, displays an evolutionarily conserved Pol β-type DNA polymerase core, in which most of the key residues involved in DNA binding, nucleotide binding, dRPase and polymerization catalysis are conserved. In agreement with this, Li Pol β, overproduced in Escherichia coli, displayed intrinsic DNA polymerase activity. Cell synchronization experiments showed a correlation between both Li Pol β mRNA and protein levels along the parasite cell cycle. Analysis of these parameters at the different growth phases of the parasite, from the proliferative (non-infective) logarithmic phase to the non-dividing (highly infectious) stationary phase, showed high levels of Li Pol β at the infective phase of the parasite. The data suggest a role of Li Pol β in base excision repair in L.infantum, a parasite usually affected by oxygen stress environments into the macrophage host cells. PMID:11557814
Leon, Jaime; Medina-Garrido, Elena; Núñez, Juan L
2017-01-01
Math achievement and engagement declines in secondary education; therefore, educators are faced with the challenge of engaging students to avoid school failure. Within self-determination theory, we address the need to assess comprehensively student perceptions of teaching quality that predict engagement and achievement. In study one we tested, in a sample of 548 high school students, a preliminary version of a scale to assess nine factors: teaching for relevance, acknowledge negative feelings, participation encouragement, controlling language, optimal challenge, focus on the process, class structure, positive feedback, and caring. In the second study, we analyzed the scale's reliability and validity in a sample of 1555 high school students. The scale showed evidence of reliability, and with regard to criterion validity, at the classroom level, teaching quality was a predictor of behavioral engagement, and higher grades were observed in classes where students, as a whole, displayed more behavioral engagement. At the within level, behavioral engagement was associated with achievement. We not only provide a reliable and valid method to assess teaching quality, but also a method to design interventions, these could be designed based on the scale items to encourage students to persist and display more engagement on school duties, which in turn bolsters student achievement.
Biondo, Ronaldo; da Silva, Felipe Almeida; Vicente, Elisabete José; Souza Sarkis, Jorge Eduardo; Schenberg, Ana Clara Guerrini
2012-08-07
This work describes the effects of the cell surface display of a synthetic phytochelatin in the highly metal tolerant bacterium Cupriavidus metallidurans CH34. The EC20sp synthetic phytochelatin gene was fused between the coding sequences of the signal peptide (SS) and of the autotransporter β-domain of the Neisseria gonorrhoeae IgA protease precursor (IgAβ), which successfully targeted the hybrid protein toward the C. metallidurans outer membrane. The expression of the SS-EC20sp-IgAβ gene fusion was driven by a modified version of the Bacillus subtilis mrgA promoter showing high level basal gene expression that is further enhanced by metal presence in C. metallidurans. The recombinant strain showed increased ability to immobilize Pb(2+), Zn(2+), Cu(2+), Cd(2+), Mn(2+), and Ni(2+) ions from the external medium when compared to the control strain. To ensure plasmid stability and biological containment, the MOB region of the plasmid was replaced by the E. coli hok/sok coding sequence.
Wen, Xiaoye; Wang, Qi; Fan, Zhefeng
2018-07-12
A novel dual-sensing fluorescence probe L was designed and synthesized for highly selective and sensitive detection of Zn 2+ and DNA. The probe L achieved a detection limit of 3.8 nM for Zn 2+ , which is lower than the acceptable level of Zn 2+ in living cells. The probe L displayed high selectivity toward Zn 2+ over other interference metal ions and amino acids. Moreover, the probe L displayed low cytotoxicity and good cell permeability, indicating its potential for detecting and bio-imaging of Zn 2+ . In addition, the probe L-Zn 2+ exhibited enhanced fluorescence signal for DNA detection through the metal-coordination interaction between Zn 2+ and DNA. The enhanced signal is higher than that of the classical ethidium bromide probe. The experiments in aqueous media verified the feasibility of applying probe L in real samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Towards revealing the structure of bacterial inclusion bodies
2009-01-01
Protein aggregation is a widely observed phenomenon in human diseases, biopharmaceutical production, and biological research. Protein aggregates are generally classified as highly ordered, such as amyloid fibrils, or amorphous, such as bacterial inclusion bodies. Amyloid fibrils are elongated filaments with diameters of 6–12 nm, they are comprised of residue-specific cross-β structure, and display characteristic properties, such as binding with amyloid-specific dyes. Amyloid fibrils are associated with dozens of human pathological conditions, including Alzheimer disease and prion diseases. Distinguished from amyloid fibrils, bacterial inclusion bodies display apparent amorphous morphology. Inclusion bodies are formed during high-level recombinant protein production, and formation of inclusion bodies is a major concern in biotechnology. Despite of the distinctive morphological difference, bacterial inclusion bodies have been found to have some amyloid-like properties, suggesting that they might contain structures similar to amyloid-like fibrils. Recent structural data further support this hypothesis, and this review summarizes the latest progress towards revealing the structural details of bacterial inclusion bodies. PMID:19806034
Towards revealing the structure of bacterial inclusion bodies.
Wang, Lei
2009-01-01
Protein aggregation is a widely observed phenomenon in human diseases, biopharmaceutical production, and biological research. Protein aggregates are generally classified as highly ordered, such as amyloid fibrils, or amorphous, such as bacterial inclusion bodies. Amyloid fibrils are elongated filaments with diameters of 6-12 nm, they are comprised of residue-specific cross-beta structure, and display characteristic properties, such as binding with amyloid-specific dyes. Amyloid fibrils are associated with dozens of human pathological conditions, including Alzheimer disease and prion diseases. Distinguished from amyloid fibrils, bacterial inclusion bodies display apparent amorphous morphology. Inclusion bodies are formed during high-level recombinant protein production, and formation of inclusion bodies is a major concern in biotechnology. Despite of the distinctive morphological difference, bacterial inclusion bodies have been found to have some amyloid-like properties, suggesting that they might contain structures similar to amyloid-like fibrils. Recent structural data further support this hypothesis, and this review summarizes the latest progress towards revealing the structural details of bacterial inclusion bodies.
F-22 cockpit avionics: a systems integration success story
NASA Astrophysics Data System (ADS)
Greeley, Kevin W.; Schwartz, Richard J.
2000-08-01
The F-22 'Raptor' is being developed and manufactured as multi-role fighter aircraft for the 'air dominance' mission. The F-22 team is led by Lockheed Martin, with Boeing and Pratt & Whitney as partners. The F-22 weapons system combines supersonic cruise, maneuverability, stealth, and an extensive suite of tightly integrated sensors to achieve a high level of lethality and invulnerability against current and projected threat systems such as fighter aircraft and surface to air missiles. Despite high automation of the complex systems installed in the F-22, the pilot is heavily tasked for air battle management. Response timelines are compressed due to supersonic cruise velocities. These factors challenge the Pilot Vehicle Interface (PVI) design. This paper discusses the team's response to these challenges, describing the physical cockpit layout, its controls and displays, and the hardware architecture, software tools, and development process used to mature the F-22 'Raptor' weapons system, including a review of Human Factors design considerations for F-22 displays.
Vasan, S N Swetadri; Ionita, Ciprian N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S
2012-02-23
We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.
Antonelli, Lis R. V.; Leoratti, Fabiana M. S.; Costa, Pedro A. C.; Rocha, Bruno C.; Diniz, Suelen Q.; Tada, Mauro S.; Pereira, Dhelio B.; Teixeira-Carvalho, Andrea; Golenbock, Douglas T.; Gonçalves, Ricardo; Gazzinelli, Ricardo T.
2014-01-01
Infection with Plasmodium vivax results in strong activation of monocytes, which are important components of both the systemic inflammatory response and parasite control. The overall goal of this study was to define the role of monocytes during P. vivax malaria. Here, we demonstrate that P. vivax–infected patients display significant increase in circulating monocytes, which were defined as CD14+CD16− (classical), CD14+CD16+ (inflammatory), and CD14loCD16+ (patrolling) cells. While the classical and inflammatory monocytes were found to be the primary source of pro-inflammatory cytokines, the CD16+ cells, in particular the CD14+CD16+ monocytes, expressed the highest levels of activation markers, which included chemokine receptors and adhesion molecules. Morphologically, CD14+ were distinguished from CD14lo monocytes by displaying larger and more active mitochondria. CD14+CD16+ monocytes were more efficient in phagocytizing P. vivax-infected reticulocytes, which induced them to produce high levels of intracellular TNF-α and reactive oxygen species. Importantly, antibodies specific for ICAM-1, PECAM-1 or LFA-1 efficiently blocked the phagocytosis of infected reticulocytes by monocytes. Hence, our results provide key information on the mechanism by which CD14+CD16+ cells control parasite burden, supporting the hypothesis that they play a role in resistance to P. vivax infection. PMID:25233271
Monoamine oxidase A and A/B knockout mice display autistic-like features
Bortolato, Marco; Godar, Sean C.; Alzghoul, Loai; Zhang, Junlin; Darling, Ryan D.; Simpson, Kimberly L.; Bini, Valentina; Chen, Kevin; Wellman, Cara L.; Lin, Rick C. S.; Shih, Jean C.
2012-01-01
Converging lines of evidence show that a sizable subset of autism-spectrum disorders (ASDs) is characterized by increased blood levels of serotonin (5-hydroxytryptamine, 5-HT), yet the mechanistic link between these two phenomena remains unclear. The enzymatic degradation of brain 5-HT is mainly mediated by monoamine oxidase (MAO)A and, in the absence of this enzyme, by its cognate isoenzyme MAOB. MAOA and A/B knockout (KO) mice display high 5-HT levels, particularly during early developmental stages. Here we show that both mutant lines exhibit numerous behavioural hallmarks of ASDs, such as social and communication impairments, perseverative and stereotypical responses, behavioural inflexibility, as well as subtle tactile and motor deficits. Furthermore, both MAOA and A/B KO mice displayed neuropathological alterations reminiscent of typical ASD features, including reduced thickness of the corpus callosum, increased dendritic arborization of pyramidal neurons in the prefrontal cortex and disrupted microarchitecture of the cerebellum. The severity of repetitive responses and neuropathological aberrances was generally greater in MAOA/B KO animals. These findings suggest that the neurochemical imbalances induced by MAOAdeficiency (either by itself or in conjunction with lack of MAOB) may result in an array of abnormalities similar to those observed in ASDs. Thus, MAOA and A/B KO mice may afford valuable models to help elucidate the neurobiological bases of these disorders and related neurodevelopmental problems. PMID:22850464
Leung, Carol S; Haigh, Tracey A; Mackay, Laura K; Rickinson, Alan B; Taylor, Graham S
2010-02-02
Whereas exogenously acquired proteins are the major source of antigens feeding the MHC class II pathway in antigen-presenting cells, some endogenously expressed antigens also access that pathway but the rules governing such access are poorly understood. Here we address this using Epstein-Barr virus (EBV)-coded nuclear antigen EBNA1, a protein naturally expressed in EBV-infected B lymphoblastoid cell lines (LCLs) and a source of multiple CD4(+) T cell epitopes. Using CD4(+) T cell clones against three indicator epitopes, we find that two epitopes are weakly displayed on the LCL surface whereas the third is undetectable, a pattern of limited epitope presentation that is maintained even when nuclear expression of EBNA1 is induced to high supraphysiological levels. Inhibitor and siRNA studies show that, of the two epitopes weakly presented under these conditions, one involves macroautophagy, and the second involves antigen delivery to the MHC II pathway by another endogenous route. In contrast, when EBNA1 is expressed as a cytoplasmic protein, all three CD4 epitopes are processed and presented much more efficiently, and all involve macroautophagy. We conclude that EBNA1's nuclear location limits its accessibility to the macroautophagy pathway and, in consequence, limits the level and range of EBNA1 CD4 epitopes naturally displayed on the infected cell surface.
Pilot/Vehicle display development from simulation to flight
NASA Technical Reports Server (NTRS)
Dare, Alan R.; Burley, James R., II
1992-01-01
The Pilot Vehicle Interface Group, Cockpit Technology Branch, Flight Management Division, at the NASA Langley Research Center is developing display concepts for air combat in the next generation of highly maneuverable aircraft. The High-Alpha Technology Program, under which the research is being done, is involved in flight tests of many new control and display concepts on the High-Alpha Research Vehicle, a highly modified F-18 aircraft. In order to support display concept development through flight testing, a software/hardware system is being developed which will support each phase of the project with little or no software modifications, thus saving thousands of manhours in software development time. Simulation experiments are in progress now and flight tests are slated to begin in FY1994.
ERIC Educational Resources Information Center
Türk, Emine; Erçetin, Gülcan
2014-01-01
This study examines the effects of interactive versus simultaneous display of visual and verbal multimedia information on incidental vocabulary learning and reading comprehension of learners of English with lower proficiency levels. In the interactive display condition, learners were allowed to select the type of multimedia information whereas the…
The roles of sex and serotonin transporter levels in age- and stress-related emotionality in mice.
Joeyen-Waldorf, Jennifer; Edgar, Nicole; Sibille, Etienne
2009-08-25
Mood disorders are influenced by genetic make-up and differentially affect men and women. The s/l promoter polymorphism in the serotonin transporter (SERT) gene moderates both trait emotion and the vulnerability to develop depressive states in humans. Similarly, male mice lacking SERT (Knockout/KO) display an elevated emotionality phenotype. We now report that the SERT-KO phenotype is maintained throughout late-adulthood, and that female KO mice develop a larger emotionality phenotype with increasing age. Thus, to test the hypothesis that these findings reflected a putative sexual dimorphism in SERT-mediated modulation of emotionality, we submitted adult male and female wild-type, heterozygous (HZ) and KO mice to unpredictable chronic mild stress (UCMS) and assessed behavioral changes. In males, the elevated SERT-KO emotion-related behavior converged with other groups after UCMS. Conversely, female SERT-KO displayed a normal non-stressed baseline, but highest UCMS-induced emotionality. SERT-HZ displayed variable and intermediate phenotypes in both experiments. Thus, consistent results across different biological modalities (age, stress) revealed a high contribution of SERT genotype for baseline "trait" emotionality in males, and low contribution for females. In contrast, age-correlated and stress-induced behavioral changes resulted in a high SERT genotype-mediated behavioral variance in females, but low in males. This suggests that high emotionality states associated with low SERT were differentially achieved in males (high baseline/trait) compared to females (increased vulnerability to develop high emotionality). This sex-by-SERT double dissociation provides a framework to investigate molecular substrates of emotionality regulation in concert with serotonin function and may contribute to the sexually dimorphic features of mood disorders.
Mevorach, Carmel; Tsal, Yehoshua; Humphreys, Glyn W
2014-01-10
According to perceptual load theory (Lavie, 2005) distractor interference is determined by the availability of attentional resources. If target processing does not exhaust resources (with low perceptual load) distractor processing will take place resulting in interference with a primary task; however, when target processing uses-up attentional capacity (with high perceptual load) interference can be avoided. An alternative account (Tsal and Benoni, 2010a) suggests that perceptual load effects can be based on distractor dilution by the mere presence of additional neutral items in high-load displays so that the effect is not driven by the amount of attention resources required for target processing. Here we tested whether patients with unilateral neglect or extinction would show dilution effects from neutral items in their contralesional (neglected/extinguished) field, even though these items do not impose increased perceptual load on the target and at the same time attract reduced attentional resources compared to stimuli in the ipsilesional field. Thus, such items do not affect the amount of attention resources available for distractor processing. We found that contralesional neutral elements can eliminate distractor interference as strongly as centrally presented ones in neglect/extinction patients, despite contralesional items being less well attended. The data are consistent with an account in terms of perceptual dilution of distracters rather than available resources for distractor processing. We conclude that distractor dilution can underlie the elimination of distractor interference in visual displays.
Schlinger, Barney A.; Barske, Julia; Day, Lainy; Fusani, Leonida; Fuxjager, Matthew J.
2014-01-01
Many animals engage in spectacular courtship displays, likely recruiting specialized neural, hormonal and muscular systems to facilitate these performances. Male golden-collared manakins (Manacus vitellinus) of Panamanian rainforests perform physically elaborate courtship displays that include novel forms of visual and acoustic signaling. We study the behavioral neuroendocrinology of this male’s courtship, combining field behavioral observations with anatomical, biochemical and molecular laboratory-based studies. Seasonally, male courtship is activated by testosterone with little correspondence between testosterone levels and display intensity. Females prefer males whose displays are exceptionally frequent, fast and accurate. The activation of androgen receptors (AR) is crucial for optimal display performance, with AR expressed at elevated levels in several neuromuscular tissues. Apparently, courtship enlists an elaborate androgen-dependent network that includes spinal motoneurons, skeletal muscles and somatosensory systems. This work highlights the value of studying non-traditional species to illuminate physiological adaptations and, hopefully, stimulates future research on other species with complex behaviors. PMID:23624091
U.S. Level III and IV Ecoregions (U.S. EPA)
This map service displays Level III and Level IV Ecoregions of the United States and was created from ecoregion data obtained from the U.S. Environmental Protection Agency Office of Research and Development's Western Ecology Division. The original ecoregion data was projected from Albers to Web Mercator for this map service. To download shapefiles of ecoregion data (in Albers), please go to: ftp://newftp.epa.gov/EPADataCommons/ORD/Ecoregions/. IMPORTANT NOTE ABOUT LEVEL IV POLYGON LEGEND DISPLAY IN ARCMAP: Due to the limitations of Graphical Device Interface (GDI) resources per application on Windows, ArcMap does not display the legend in the Table of Contents for the ArcGIS Server service layer if the legend has more than 100 items. As of December 2011, there are 968 unique legend items in the Level IV Ecoregion Polygon legend. Follow this link (http://support.esri.com/en/knowledgebase/techarticles/detail/33741) for instructions about how to increase the maximum number of ArcGIS Server service layer legend items allowed for display in ArcMap. Note the instructions at this link provide a slightly incorrect path to Maximum Legend Count. The correct path is HKEY_CURRENT_USER > Software > ESRI > ArcMap > Server > MapServerLayer > Maximum Legend Count. When editing the Maximum Legend Count, update the field, Value data to 1000. To download a PDF version of the Level IV ecoregion map and legend, go to ftp://newftp.epa.gov/EPADataCommons/ORD/Ecoregions/us/Eco_Level_IV
Caminos, Elena; Vaquero, Cecilia F; García-Olmo, Dolores C
2014-12-01
Characterization of retinal cells, cell transplants and gene therapies may be helped by pre-labeled retinal cells, such as those transfected with vectors for green fluorescent protein expression. The aim of this study was to analyze retinal cells and optic nerve components from transgenic green mice (GM) with the 'enhanced' green fluorescent protein (EGFP) gene under the control of the CAG promoter (a chicken β-actin promoter and a cytomegalovirus enhancer). The structural analysis and electroretinography recordings showed a normal, healthy retina. Surprisingly, EGFP expression was not ubiquitously located in the retina and optic nerve. Epithelial cells, photoreceptors and bipolar cells presented high green fluorescence levels. In contrast, horizontal cells, specific amacrine cells and ganglion cells exhibited a null EGFP expression level. The synaptic terminals of rod bipolar cells displayed a high green fluorescence level when animals were kept in the dark. Immature retinas exhibited different EGFP expression patterns to those noted in adults. Axons and glial cells in the optic nerve revealed a specific regional EGFP expression pattern, which correlated with the presence of myelin. These results suggest that EGFP expression might be related to the activity of both the CAG promoter and β-actin in mature retinal neurons and oligodendrocytes. Moreover, EGFP expression might be regulated by light in both immature and adult animals. Since GM are used in numerous retina bioassays, it is essential to know the differential EGFP expression in order to select cells of interest for each study.
Tactile cueing effects on performance in simulated aerial combat with high acceleration.
van Erp, Jan B F; Eriksson, Lars; Levin, Britta; Carlander, Otto; Veltman, J A; Vos, Wouter K
2007-12-01
Recent evidence indicates that vibrotactile displays can potentially reduce the risk of sensory and cognitive overload. Before these displays can be introduced in super agile aircraft, it must be ascertained that vibratory stimuli can be sensed and interpreted by pilots subjected to high G loads. Each of 9 pilots intercepted 32 targets in the Swedish Dynamic Flight Simulator. Targets were indicated on simulated standard Gripen visual displays. In addition, in half of the trials target direction was also displayed on a 60-element tactile torso display. Performance measures and subjective ratings were recorded. Each pilot pulled G peaks above +8 Gz. With tactile cueing present, mean reaction time was reduced from 1458 ms (SE = 54) to 1245 ms (SE = 88). Mean total chase time for targets that popped up behind the pilot's aircraft was reduced from 13 s (SE = 0.45) to 12 s (SE = 0.41). Pilots rated the tactile display favorably over the visual displays at target pop-up on the easiness of detecting a threat presence and on the clarity of initial position of the threats. This study is the first to show that tactile display information is perceivable and useful in hypergravity (up to +9 Gz). The results show that the tactile display can capture attention at threat pop-up and improve threat awareness for threats in the back, even in the presence of high-end visual displays. It is expected that the added value of tactile displays may further increase after formal training and in situations of unexpected target pop-up.
Branis, Martin; Linhartova, Martina
2012-09-01
We analyzed differentials in exposure to SO(2), PM(10) and NO(2) among Czech urban populations categorized according to education level, unemployment rate, population size and average annual salary. Altogether 39 cities were included in the analysis. The principal component analysis revealed two factors explaining 72.8% of the data variability. The first factor explaining 44.7% of the data variability included SO(2), PM(10), low education level and high unemployment, documenting that inhabitants with unfavorable socioeconomic status mainly reside in smaller cities with higher concentration levels of combustion-related air pollutants. The second factor explaining 28.1% of the data variability included NO(2), high salary, high education level and large population, suggesting that large cities with residents with higher socioeconomic status are exposed to higher levels of traffic-related air pollution. We conclude that, after more than a decade of free-market economy, the Czech Republic, a former Soviet satellite with a centrally planned economy, displays signs of a certain kind of environmental inequality, since environmental hazards are unevenly distributed among the Czech urban populations. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chun, Won-Suk; Napoli, Joshua; Cossairt, Oliver S.; Dorval, Rick K.; Hall, Deirdre M.; Purtell, Thomas J., II; Schooler, James F.; Banker, Yigal; Favalora, Gregg E.
2005-03-01
We present a software and hardware foundation to enable the rapid adoption of 3-D displays. Different 3-D displays - such as multiplanar, multiview, and electroholographic displays - naturally require different rendering methods. The adoption of these displays in the marketplace will be accelerated by a common software framework. The authors designed the SpatialGL API, a new rendering framework that unifies these display methods under one interface. SpatialGL enables complementary visualization assets to coexist through a uniform infrastructure. Also, SpatialGL supports legacy interfaces such as the OpenGL API. The authors" first implementation of SpatialGL uses multiview and multislice rendering algorithms to exploit the performance of modern graphics processing units (GPUs) to enable real-time visualization of 3-D graphics from medical imaging, oil & gas exploration, and homeland security. At the time of writing, SpatialGL runs on COTS workstations (both Windows and Linux) and on Actuality"s high-performance embedded computational engine that couples an NVIDIA GeForce 6800 Ultra GPU, an AMD Athlon 64 processor, and a proprietary, high-speed, programmable volumetric frame buffer that interfaces to a 1024 x 768 x 3 digital projector. Progress is illustrated using an off-the-shelf multiview display, Actuality"s multiplanar Perspecta Spatial 3D System, and an experimental multiview display. The experimental display is a quasi-holographic view-sequential system that generates aerial imagery measuring 30 mm x 25 mm x 25 mm, providing 198 horizontal views.
Polymer Dispersed Liquid Crystal Displays
NASA Astrophysics Data System (ADS)
Doane, J. William
The following sections are included: * INTRODUCTION AND HISTORICAL DEVELOPMENT * PDLC MATERIALS PREPARATION * Polymerization induced phase separation (PIPS) * Thermally induced phase separation (TIPS) * Solvent induced phase separation (SIPS) * Encapsulation (NCAP) * RESPONSE VOLTAGE * Dielectric and resistive effects * Radial configuration * Bipolar configuration * Other director configurations * RESPONSE TIME * DISPLAY CONTRAST * Light scattering and index matching * Incorporation of dyes * Contrast measurements * PDLC DISPLAY DEVICES AND INNOVATIONS * Reflective direct view displays * Large-scale, flexible displays * Switchable windows * Projection displays * High definition spatial light modulator * Haze-free PDLC shutters: wide angle view displays * ENVIRONMENTAL STABILITY * ACKNOWLEDGEMENTS * REFERENCES
Thompson, Cynthia L; Powell, Brianna L; Williams, Susan H; Hanya, Goro; Glander, Kenneth E; Vinyard, Christopher J
2017-11-01
Thyroid hormones boost animals' basal metabolic rate and represent an important thermoregulatory pathway for mammals that face cold temperatures. Whereas the cold thermal pressures experienced by primates in seasonal habitats at high latitudes and elevations are often apparent, tropical habitats also display distinct wet and dry seasons with modest changes in thermal environment. We assessed seasonal and temperature-related changes in thyroid hormone levels for two primate species in disparate thermal environments, tropical mantled howlers (Alouatta palliata), and seasonally cold-habitat Japanese macaques (Macaca fuscata). We collected urine and feces from animals and used ELISA to quantify levels of the thyroid hormone triiodothyronine (fT 3 ). For both species, fT 3 levels were significantly higher during the cooler season (wet/winter), consistent with a thermoregulatory role. Likewise, both species displayed greater temperature deficits (i.e., the degree to which animals warm their body temperature relative to ambient) during the cooler season, indicating greater thermoregulatory pressures during this time. Independently of season, Japanese macaques displayed increasing fT 3 levels with decreasing recently experienced maximum temperatures, but no relationship between fT 3 and recently experienced minimum temperatures. Howlers increased fT 3 levels as recently experienced minimum temperatures decreased, although demonstrated the opposite relationship with maximum temperatures. This may reflect natural thermal variation in howlers' habitat: wet seasons had cooler minimum and mean temperatures than the dry season, but similar maximum temperatures. Overall, our findings support the hypothesis that both tropical howlers and seasonally cold-habitat Japanese macaques utilize thyroid hormones as a mechanism to boost metabolism in response to thermoregulatory pressures. This implies that cool thermal pressures faced by tropical primates are sufficient to invoke an energetically costly and relatively longer-term thermoregulatory pathway. The well-established relationship between thyroid hormones and energetics suggests that the seasonal hormonal changes we observed could influence many commonly studied behaviors including food choice, range use, and activity patterns. © 2017 Wiley Periodicals, Inc.
Behaviour problems and cortisol levels in very-low-birth-weight children.
Wadsby, Marie; Nelson, Nina; Ingemansson, Fredrik; Samuelsson, Stefan; Leijon, Ingemar
2014-11-01
Abstract Background. There are still diverging results concerning the behaviour of children with very-low-birth-weight (VLBW) and they have been questioned to display different levels of stress hormone than normal-birth-weight (NBW) children. Aims. This study examined behaviour and the stress hormone cortisol in children with VLBW at the ages of 7 and 9 years compared with children with NBW. Results. Fifty-one VLBW and 50 NBW children were studied with the Child Behavior Checklist. Cortisol rhythm was measured through saliva samples three times a day for 2 days. VLBW children displayed more behavioural problems than NBW children, specifically social and attention problems, although still within normal ranges. They showed lower cortisol levels both at 7 and 9 years of age. No strong association between behaviour and cortisol levels was shown. Conclusion. VLBW children display more behaviour problems compared with NBW children but both groups score are within the normal range. Down-regulation of their hypothalamic-pituitary-adrenal (HPA) function in terms of lower cortisol levels is also noted.
Tervo, Outi M; Christoffersen, Mads F; Simon, Malene; Miller, Lee A; Jensen, Frants H; Parks, Susan E; Madsen, Peter T
2012-01-01
The low-frequency, powerful vocalizations of blue and fin whales may potentially be detected by conspecifics across entire ocean basins. In contrast, humpback and bowhead whales produce equally powerful, but more complex broadband vocalizations composed of higher frequencies that suffer from higher attenuation. Here we evaluate the active space of high frequency song notes of bowhead whales (Balaena mysticetus) in Western Greenland using measurements of song source levels and ambient noise. Four independent, GPS-synchronized hydrophones were deployed through holes in the ice to localize vocalizing bowhead whales, estimate source levels and measure ambient noise. The song had a mean apparent source level of 185±2 dB rms re 1 µPa @ 1 m and a high mean centroid frequency of 444±48 Hz. Using measured ambient noise levels in the area and Arctic sound spreading models, the estimated active space of these song notes is between 40 and 130 km, an order of magnitude smaller than the estimated active space of low frequency blue and fin whale songs produced at similar source levels and for similar noise conditions. We propose that bowhead whales spatially compensate for their smaller communication range through mating aggregations that co-evolved with broadband song to form a complex and dynamic acoustically mediated sexual display.
Tervo, Outi M.; Christoffersen, Mads F.; Simon, Malene; Miller, Lee A.; Jensen, Frants H.; Parks, Susan E.; Madsen, Peter T.
2012-01-01
The low-frequency, powerful vocalizations of blue and fin whales may potentially be detected by conspecifics across entire ocean basins. In contrast, humpback and bowhead whales produce equally powerful, but more complex broadband vocalizations composed of higher frequencies that suffer from higher attenuation. Here we evaluate the active space of high frequency song notes of bowhead whales (Balaena mysticetus) in Western Greenland using measurements of song source levels and ambient noise. Four independent, GPS-synchronized hydrophones were deployed through holes in the ice to localize vocalizing bowhead whales, estimate source levels and measure ambient noise. The song had a mean apparent source level of 185±2 dB rms re 1 µPa @ 1 m and a high mean centroid frequency of 444±48 Hz. Using measured ambient noise levels in the area and Arctic sound spreading models, the estimated active space of these song notes is between 40 and 130 km, an order of magnitude smaller than the estimated active space of low frequency blue and fin whale songs produced at similar source levels and for similar noise conditions. We propose that bowhead whales spatially compensate for their smaller communication range through mating aggregations that co-evolved with broadband song to form a complex and dynamic acoustically mediated sexual display. PMID:23300591
Low-quality birds do not display high-quality signals: The cysteine-pheomelanin mechanism of honesty
Galván, Ismael; Wakamatsu, Kazumasa; Camarero, Pablo R; Mateo, Rafael; Alonso-Alvarez, Carlos
2015-01-01
The mechanisms that make that the costs of producing high-quality signals are unaffordable to low-quality signalers are a current issue in animal communication. The size of the melanin-based bib of male house sparrows Passer domesticus honestly signals quality. We induced the development of new bibs while treating males with buthionine-sulfoximine (BSO), a substance that depletes the levels of the antioxidant glutathione (GSH) and the amino acid cysteine, two elements that switch melanogenesis from eumelanin to pheomelanin. Final bib size is negatively related to pheomelanin levels in the bib feathers. BSO reduced cysteine and GSH levels in all birds, but improved phenotypes (bibs larger than controls) were only expressed by high-quality birds (BSO birds with largest bibs initially). Negative associations between final bib size and cysteine levels in erythrocytes, and between pheomelanin and cysteine levels, were observed in high-quality birds only. These findings suggest that a mechanism uncoupling pheomelanin and cysteine levels may have evolved in low-quality birds to avoid producing bibs of size not corresponding to their quality and greater relative costs. Indeed, greater oxidative stress in cells was not observed in low-quality birds. This may represent the first mechanism maintaining signal honesty without producing greater relative costs on low-quality signalers. PMID:25330349
2008-01-01
Background Exaggerated male ornaments and displays often evolve in species where males only provide females with ejaculates during reproduction. Although "good genes" arguments are typically invoked to explain this phenomenon, a simpler alternative is possible if variation in male reproductive quality (e.g. sperm number, ejaculate content, mating rate) is an important determinant of female reproductive success. The "phenotype-linked fertility hypothesis" states that female preference for male ornaments or displays has been selected to ensure higher levels of fertility and has driven the evolution of exaggerated male traits. Females of the stalk-eyed fly Teleopsis dalmanni must mate frequently to maintain high levels of fertility and prefer to mate with males exhibiting large eyespan, a condition-dependent sexual ornament. If eyespan indicates male reproductive quality, females could directly increase their reproductive success by mating with males with large eyespan. Here we investigate whether male eyespan indicates accessory gland and testis length, and then ask whether mating with large eyespan males affects female fertility. Results Male eyespan was a better predictor of two key male reproductive traits – accessory gland and testis length – than was body size alone. This positive relationship held true over three levels of increasing environmental stress during the maturation of the adult accessory glands and testes. Furthermore, females housed with a large eyespan male exhibited higher levels of fertility than those with small eyespan males. Conclusion Male eyespan in stalk-eyed flies is subject to strong directional mate preference and is a reliable indicator of male reproductive quality – both because males with larger eyespan have bigger accessory glands and testes, and also as they confer higher fertility on females. Fertility enhancement may have arisen because males with larger eyespan mated more often and/or because they transferred more sperm or other substances per ejaculate. The need to ensure high levels of fertility could thus have been an important selective force in the coevolution of female preference and male eyespan in stalk-eyed flies. Our results support the phenotype-linked fertility hypothesis and suggest that it might be of general importance in explaining the evolution of exaggerated male ornaments and displays in species where males only provide females with ejaculates during reproduction. PMID:18710553
Rogers, David W; Denniff, Matthew; Chapman, Tracey; Fowler, Kevin; Pomiankowski, Andrew
2008-08-18
Exaggerated male ornaments and displays often evolve in species where males only provide females with ejaculates during reproduction. Although "good genes" arguments are typically invoked to explain this phenomenon, a simpler alternative is possible if variation in male reproductive quality (e.g. sperm number, ejaculate content, mating rate) is an important determinant of female reproductive success. The "phenotype-linked fertility hypothesis" states that female preference for male ornaments or displays has been selected to ensure higher levels of fertility and has driven the evolution of exaggerated male traits. Females of the stalk-eyed fly Teleopsis dalmanni must mate frequently to maintain high levels of fertility and prefer to mate with males exhibiting large eyespan, a condition-dependent sexual ornament. If eyespan indicates male reproductive quality, females could directly increase their reproductive success by mating with males with large eyespan. Here we investigate whether male eyespan indicates accessory gland and testis length, and then ask whether mating with large eyespan males affects female fertility. Male eyespan was a better predictor of two key male reproductive traits--accessory gland and testis length--than was body size alone. This positive relationship held true over three levels of increasing environmental stress during the maturation of the adult accessory glands and testes. Furthermore, females housed with a large eyespan male exhibited higher levels of fertility than those with small eyespan males. Male eyespan in stalk-eyed flies is subject to strong directional mate preference and is a reliable indicator of male reproductive quality--both because males with larger eyespan have bigger accessory glands and testes, and also as they confer higher fertility on females. Fertility enhancement may have arisen because males with larger eyespan mated more often and/or because they transferred more sperm or other substances per ejaculate. The need to ensure high levels of fertility could thus have been an important selective force in the coevolution of female preference and male eyespan in stalk-eyed flies. Our results support the phenotype-linked fertility hypothesis and suggest that it might be of general importance in explaining the evolution of exaggerated male ornaments and displays in species where males only provide females with ejaculates during reproduction.
Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics
NASA Astrophysics Data System (ADS)
Tsai, Meng-Che; Lee, Tsung-Xian
2017-02-01
Due to the worldwide portable devices and illumination technology trends, researches interest in laser diodes applications are booming in recent years. One of the popular and potential LDs applications is near-eye display used in VR/AR. An ideal near-eye display needs to provide high resolution, wide FOV imagery with compact magnifying optics, and long battery life for prolonged use. However, previous studies still cannot reach high light utilization efficiency in illumination and imaging optical systems which should be raised as possible to increase wear comfort. To meet these needs, a waveguide illumination system of near-eye display is presented in this paper. We focused on proposing a high efficiency RGB LDs light engine which could reduce power consumption and increase flexibility of mechanism design by using freeform TIR reflectors instead of beam splitters. By these structures, the total system efficiency of near-eye display is successfully increased, and the improved results in efficiency and fabrication tolerance of near-eye displays are shown in this paper.
Handa, Kazuko; Takatani-Nakase, Tomoka; Larue, Lionel; Stemmler, Marc P; Kemler, Rolf; Hakomori, Sen-itiroh
2007-06-22
Le(x) glycan and E-cadherin (Ecad) are co-expressed at embryonal stem (ES) cells and embryonal carcinoma (EC) cells. While the structure and function of Ecad mediating homotypic adhesion of these cells have been well established, evidence that Le(x) glycan also mediates such adhesion is weak, despite the fact that Le(x) oligosaccharide inhibits the compaction process. To provide stronger evidence, we knocked out Ecad gene in EC and ES cells to establish F9 Ecad (-/-) and D3M Ecad (-/-) cells, which highly express Le(x) glycan but do not express Ecad at all. Both F9 Ecad (-/-) and D3M Ecad (-/-) cells displayed strong autoaggregation in the presence of Ca(2+), while PYS-2 cells, which express trace amount of Ecad and undetectable level of Le(x) glycan, did not display autoaggregation. In addition, F9 Ecad (-/-) and D3M Ecad (-/-) cells displayed strong adhesion to plates coated with Le(x) glycosphingolipid (III(3)FucnLc4Cer), in dose-dependent manner, in the presence of Ca(2+). Thus, ES or EC cells display autoaggregation and strong adhesion to Le(x)-coated plates in the absence of Ecad, further supporting the notion of Le(x) self-recognition (i.e., Le(x)-to-Le(x) interaction) in cell adhesion.
Cell Surface Display of MerR on Saccharomyces cerevisiae for Biosorption of Mercury.
Wei, Qinguo; Yan, Jiakuo; Chen, Yao; Zhang, Lei; Wu, Xiaoyang; Shang, Shuai; Ma, Shisheng; Xia, Tian; Xue, Shuyu; Zhang, Honghai
2018-01-01
The metalloregulatory protein MerR which plays important roles in mer operon system exhibits high affinity and selectivity toward mercury (II) (Hg 2+ ). In order to improve the adsorption ability of Saccharomyces cerevisiae for Hg 2+ , MerR was displayed on the surface of S. cerevisiae for the first time with an α-agglutinin-based display system in this study. The merR gene was synthesized after being optimized and added restriction endonuclease sites EcoR I and Mlu I. The display of MerR was indirectly confirmed by the enhanced adsorption ability of S. cerevisiae for Hg 2+ and colony PCR. The hydride generation atomic absorption spectrometry was applied to measure the Hg 2+ content in water. The engineered yeast strain not only showed higher tolerance to Hg, but also their adsorption ability was much higher than that of origin and control strains. The engineered yeast could adsorb Hg 2+ under a wide range of pH levels, and it could also adsorb Hg 2+ effectively with Cd 2+ and Cu 2+ coexistence. Furthermore, the engineered yeast strain could adsorb ultra-trace Hg 2+ effectively. The results above showed that the surface-engineered yeast strain could adsorb Hg 2+ under complex environmental conditions and could be used for the biosorption and bioremediation of environmental Hg contaminants.
Adegoke, Samuel Chetachukwu; Thongraung, Chakree; Yupanqui, Chutha Takahashi
2018-06-23
The effect of short-chain inulin on the rheological and sensory properties of reduced fat set coconut milk yoghurt was studied with whole fat coconut milk yoghurt as reference. The concentration of short-chain inulin was varied at 0, 5, 10, 15, and 20% w/v respectively. All the yoghurt samples displayed higher elastic modulus G' than viscous modulus G". However, 15% inulin yoghurt had the highest value for G' & G". The 15 and 20% inulin yoghurts displayed high yield stress (1036.7 ± 2.39 & 368.23 ± 0.30 Pa). Addition threshold of 15% was established, beyond this level there was a significant decrease in the yield stress, firmness, cohesiveness and consistency values of the reduced fat yoghurts. Using Pearson correlation analysis, no correlation was observed between firmness and yield stress, Similarly, there was significant correlation between the yield stress and instrumental viscosity r = 0.957; p < 0.01. Furthermore, all yoghurt samples displayed strain thinning behavior except whole fat yoghurt. Carbohydrate was affected by inulin incorporation. Addition of short chain inulin improved sensorial characteristics such as taste, and flavor, but did not display significant difference in color and odor of yoghurt samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Lin, Yi-Chieh; Chen, Bing-Mae; Lu, Wei-Cheng; Su, Chien-I; Prijovich, Zeljko M.; Chung, Wen-Chuan; Wu, Pei-Yu; Chen, Kai-Chuan; Lee, I-Chiao; Juan, Ting-Yi; Roffler, Steve R.
2013-01-01
Membrane-tethered proteins (mammalian surface display) are increasingly being used for novel therapeutic and biotechnology applications. Maximizing surface expression of chimeric proteins on mammalian cells is important for these applications. We show that the cytoplasmic domain from the B7-1 antigen, a commonly used element for mammalian surface display, can enhance the intracellular transport and surface display of chimeric proteins in a Sar1 and Rab1 dependent fashion. However, mutational, alanine scanning and deletion analysis demonstrate the absence of linear ER export motifs in the B7 cytoplasmic domain. Rather, efficient intracellular transport correlated with the presence of predicted secondary structure in the cytoplasmic tail. Examination of the cytoplasmic domains of 984 human and 782 mouse type I transmembrane proteins revealed that many previously identified ER export motifs are rarely found in the cytoplasmic tail of type I transmembrane proteins. Our results suggest that efficient intracellular transport of B7 chimeric proteins is associated with the structure rather than to the presence of a linear ER export motif in the cytoplasmic tail, and indicate that short (less than ~ 10-20 amino acids) and unstructured cytoplasmic tails should be avoided to express high levels of chimeric proteins on mammalian cells. PMID:24073236
LCD displays performance comparison by MTF measurement using the white noise stimulus method
NASA Astrophysics Data System (ADS)
Mitjà, Carles; Escofet, Jaume
2011-01-01
The amount of images produced to be viewed as soft copies on output displays are significantly increasing. This growing occurs at the expense of the images targeted to hard copy versions on paper or any other physical support. Even in the case of high quality hard copy production, people working in professional imaging uses different displays in selecting, editing, processing and showing images, from laptop screen to specialized high end displays. Then, the quality performance of these devices is crucial in the chain of decisions to be taken in image production. Metrics of this quality performance can help in the equipment acquisition. Different metrics and methods have been described to determine the quality performance of CRT and LCD computer displays in clinical area. One of most important metrics in this field is the device spatial frequency response obtained measuring the modulation transfer function (MTF). This work presents a comparison between the MTF of three different LCD displays, Apple MacBook Pro 15", Apple LED Cinema Display 24" and Apple iPhone4, measured by the white noise stimulus method, over vertical and horizontal directions. Additionally, different displays show particular pixels structure pattern. In order to identify this pixel structure, a set of high magnification images is taken from each display to be related with the respective vertical and horizontal MTF.
Displaying Geographically-Based Domestic Statistics
NASA Technical Reports Server (NTRS)
Quann, J.; Dalton, J.; Banks, M.; Helfer, D.; Szczur, M.; Winkert, G.; Billingsley, J.; Borgstede, R.; Chen, J.; Chen, L.;
1982-01-01
Decision Information Display System (DIDS) is rapid-response information-retrieval and color-graphics display system. DIDS transforms tables of geographically-based domestic statistics (such as population or unemployment by county, energy usage by county, or air-quality figures) into high-resolution, color-coded maps on television display screen.
NASA Astrophysics Data System (ADS)
Morozov, Alexander; Dubinin, German; Dubynin, Sergey; Yanusik, Igor; Kim, Sun Il; Choi, Chil-Sung; Song, Hoon; Lee, Hong-Seok; Putilin, Andrey; Kopenkin, Sergey; Borodin, Yuriy
2017-06-01
Future commercialization of glasses-free holographic real 3D displays requires not only appropriate image quality but also slim design of backlight unit and whole display device to match market needs. While a lot of research aimed to solve computational issues of forming Computer Generated Holograms for 3D Holographic displays, less focus on development of backlight units suitable for 3D holographic display applications with form-factor of conventional 2D display systems. Thereby, we report coherent backlight unit for 3D holographic display with thickness comparable to commercially available 2D displays (cell phones, tablets, laptops, etc.). Coherent backlight unit forms uniform, high-collimated and effective illumination of spatial light modulator. Realization of such backlight unit is possible due to holographic optical elements, based on volume gratings, constructing coherent collimated beam to illuminate display plane. Design, recording and measurement of 5.5 inch coherent backlight unit based on two holographic optical elements are presented in this paper.
Polyplanar optic display for cockpit application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veligdan, J.; Biscardi, C.; Brewster, C.
1998-04-01
The Polyplanar Optical Display (POD) is a high contrast display screen being developed for cockpit applications. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a long lifetime, (10,000 hour), 200 mW green solid-state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments,more » Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design and speckle reduction, the authors discuss the electronic interfacing to the DLP{trademark} chip, the opto-mechanical design and viewing angle characteristics.« less
Polyplanar optic display for cockpit application
NASA Astrophysics Data System (ADS)
Veligdan, James T.; Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Freibott, William C.
1998-09-01
The Polyplanar Optical Display (POD) is a high contrast display screen being developed for cockpit applications. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a long lifetime, (10,000 hour), 200 mW green solid-state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLPTM) chip manufactured by Texas Instruments, Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design and speckle reduction, we discuss the electronic interfacing to the DLPTM chip, the opto-mechanical design and viewing angle characteristics.
Nadig, Aparna; Vivanti, Giacomo; Ozonoff, Sally
2009-12-01
This study compared the object descriptions of school-age children with high-functioning autism (HFA) with those of a matched group of typically developing children. Descriptions were elicited in a referential communication task where shared information was manipulated, and in a guessing game where clues had to be provided about the identity of an object that was hidden from the addressee. Across these tasks, increasingly complex levels of audience design were assessed: (1) the ability to give adequate descriptions from one's own perspective, (2) the ability to adjust descriptions to an addressee's perspective when this differs from one's own, and (3) the ability to provide indirect yet identifying descriptions in a situation where explicit labeling is inappropriate. Results showed that there were group differences in all three cases, with the HFA group giving less efficient descriptions with respect to the relevant context than the comparison group. More revealing was the identification of distinct adaptation profiles among the HFA participants: those who had difficulty with all three levels, those who displayed Level 1 audience design but poor Level 2 and Level 3 design, and those demonstrated all three levels of audience design, like the majority of the comparison group. Higher structural language ability, rather than symptom severity or social skills, differentiated those HFA participants with typical adaptation profiles from those who displayed deficient audience design, consistent with previous reports of language use in autism.
The Development of the AFIT Communications Laboratory and Experiments for Communications Students.
1985-12-01
Actiatesdigtal wag*andPermits monitoring of max. Actiatesdigial sorag animum signal excursions over selects the "A" or " porn indeienite time...level at which the vertical display is installed in the 71.5. either peak detected or digitally averaged. Video signals above the level set by the... Video signals below the level set by the PEAK AVERAGE control or VERT P05 Positions the display Or baseline on digitally averaged and stored. th c_
Contextual cuing: the effects of stimulus variation, intentionality, and aging.
Lyon, John; Scialfa, Charles; Cordazzo, Scheila; Bubric, Katherine
2014-06-01
Three experiments investigated the generalisation of contextual cuing and whether the effect is incidental or intentional in nature. Experiment 1 assessed contextual cuing across variations in display contrast, homogeneity, and spatial separation. Cuing effects were found with all display types and reaction-time disruption was manifested for repeated displays when consistent configurations had their target locations altered. Recognition memory for repeated displays was at chance levels. Experiment 2 showed that contextual cuing was insensitive to instructions to search for and remember repeated displays. Experiment 2A found that there were no age differences in contextual cuing or effects of intentional instructions, and no memory for repeated displays. Future research questions concern the generalisation of contextual cuing to a wider variety of display conditions and naturalistic tasks.
Re-engineering the stereoscope for the 21st Century
NASA Astrophysics Data System (ADS)
Kollin, Joel S.; Hollander, Ari J.
2007-02-01
While discussing the current state of stereo head-mounted and 3D projection displays, the authors came to the realization that flat-panel LCD displays offer higher resolution than projection for stereo display at a low (and continually dropping) cost. More specifically, where head-mounted displays of moderate resolution and field-of-view cost tens of thousands of dollars, we can achieve an angular resolution approaching that of the human eye with a field-of-view (FOV) greater than 90° for less than $1500. For many immersive applications head tracking is unnecessary and sometimes even undesirable, and a low cost/high quality wide FOV display may significantly increase the application space for 3D display. After outlining the problem and potential of this solution we describe the initial construction of a simple Wheatstone stereoscope using 24" LCD displays and then show engineering improvements that increase the FOV and usability of the system. The applicability of a high-immersion, high-resolution display for art, entertainment, and simulation is presented along with a content production system that utilizes the capabilities of the system. We then discuss the potential use of the system for VR pain control therapy, treatment of post-traumatic stress disorders and other serious games applications.
Effects of VR system fidelity on analyzing isosurface visualization of volume datasets.
Laha, Bireswar; Bowman, Doug A; Socha, John J
2014-04-01
Volume visualization is an important technique for analyzing datasets from a variety of different scientific domains. Volume data analysis is inherently difficult because volumes are three-dimensional, dense, and unfamiliar, requiring scientists to precisely control the viewpoint and to make precise spatial judgments. Researchers have proposed that more immersive (higher fidelity) VR systems might improve task performance with volume datasets, and significant results tied to different components of display fidelity have been reported. However, more information is needed to generalize these results to different task types, domains, and rendering styles. We visualized isosurfaces extracted from synchrotron microscopic computed tomography (SR-μCT) scans of beetles, in a CAVE-like display. We ran a controlled experiment evaluating the effects of three components of system fidelity (field of regard, stereoscopy, and head tracking) on a variety of abstract task categories that are applicable to various scientific domains, and also compared our results with those from our prior experiment using 3D texture-based rendering. We report many significant findings. For example, for search and spatial judgment tasks with isosurface visualization, a stereoscopic display provides better performance, but for tasks with 3D texture-based rendering, displays with higher field of regard were more effective, independent of the levels of the other display components. We also found that systems with high field of regard and head tracking improve performance in spatial judgment tasks. Our results extend existing knowledge and produce new guidelines for designing VR systems to improve the effectiveness of volume data analysis.
Speech Auditory Alerts Promote Memory for Alerted Events in a Video-Simulated Self-Driving Car Ride.
Nees, Michael A; Helbein, Benji; Porter, Anna
2016-05-01
Auditory displays could be essential to helping drivers maintain situation awareness in autonomous vehicles, but to date, few or no studies have examined the effectiveness of different types of auditory displays for this application scenario. Recent advances in the development of autonomous vehicles (i.e., self-driving cars) have suggested that widespread automation of driving may be tenable in the near future. Drivers may be required to monitor the status of automation programs and vehicle conditions as they engage in secondary leisure or work tasks (entertainment, communication, etc.) in autonomous vehicles. An experiment compared memory for alerted events-a component of Level 1 situation awareness-using speech alerts, auditory icons, and a visual control condition during a video-simulated self-driving car ride with a visual secondary task. The alerts gave information about the vehicle's operating status and the driving scenario. Speech alerts resulted in better memory for alerted events. Both auditory display types resulted in less perceived effort devoted toward the study tasks but also greater perceived annoyance with the alerts. Speech auditory displays promoted Level 1 situation awareness during a simulation of a ride in a self-driving vehicle under routine conditions, but annoyance remains a concern with auditory displays. Speech auditory displays showed promise as a means of increasing Level 1 situation awareness of routine scenarios during an autonomous vehicle ride with an unrelated secondary task. © 2016, Human Factors and Ergonomics Society.
Age related patterns of immunoglobulin serum levels in the Quechua Indians of Andean Mountains
NASA Astrophysics Data System (ADS)
Memeo, S. A.; Piantanelli, L.; Mazzufferi, G.; Guerra, L.; Nikolitz, M.; Fabris, N.
1982-03-01
Age-dependent changes of IgA, IgG, IgM, and IgD serum levels in a population of Quechua Indians of Peruvian Andes at 4 300 m were investigated. A first increase and a subsequent decrease in IgA and IgM levels were observed with advancing age. IgG and IgD only display an increase during development. More or less pronounced sex-related changes were also found in all Ig classes, the sex dependent pattern of IgA being the more evident one. It has been suggested that sexual, genetic and environmental influences strongly superimpose to high altitude related changes in Ig profile during ageing.