Emi-Flective Display Device with Attribute of High Glare-Free-Ambient-Contrast-Ratio
NASA Astrophysics Data System (ADS)
Yang, Bo-Ru; Hsu, Chuan-Wei; Shieh, Han-Ping D.
2007-11-01
We have demonstrated the integration of an organic light emitting device (OLED) and a reflective liquid crystal display (R-LCD) which was termed an emi-flective display. The glare-free-ambient-contrast-ratio (GFA-CR) was used to evaluate the image quality of display devices under ambient light. Through integrating the OLED with R-LCD, the GFA-CR of the device achieved an improvement by a factor of 8 compared with that of the OLED alone. Moreover, the integrated R-LCD showed a GFA-CR of 100:1 within a viewing cone of 20° which can suppress the wash-out of OLED and is more power-saving in the sunlight. Therefore, an emi-flective display is a promising technique for mobile applications.
Mc Laughlin, Patrick; Neill, Siobhan O; Fanning, Noel; Mc Garrigle, Anne Marie; Connor, Owen J O; Wyse, Gerry; Maher, Michael M
2012-04-01
Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.
Chen, Yan; James, Jonathan J; Turnbull, Anne E; Gale, Alastair G
2015-10-01
To establish whether lower resolution, lower cost viewing devices have the potential to deliver mammographic interpretation training. On three occasions over eight months, fourteen consultant radiologists and reporting radiographers read forty challenging digital mammography screening cases on three different displays: a digital mammography workstation, a standard LCD monitor, and a smartphone. Standard image manipulation software was available for use on all three devices. Receiver operating characteristic (ROC) analysis and ANOVA (Analysis of Variance) were used to determine the significance of differences in performance between the viewing devices with/without the application of image manipulation software. The effect of reader's experience was also assessed. Performance was significantly higher (p < .05) on the mammography workstation compared to the other two viewing devices. When image manipulation software was applied to images viewed on the standard LCD monitor, performance improved to mirror levels seen on the mammography workstation with no significant difference between the two. Image interpretation on the smartphone was uniformly poor. Film reader experience had no significant effect on performance across all three viewing devices. Lower resolution standard LCD monitors combined with appropriate image manipulation software are capable of displaying mammographic pathology, and are potentially suitable for delivering mammographic interpretation training. • This study investigates potential devices for training in mammography interpretation. • Lower resolution standard LCD monitors are potentially suitable for mammographic interpretation training. • The effect of image manipulation tools on mammography workstation viewing is insignificant. • Reader experience had no significant effect on performance in all viewing devices. • Smart phones are not suitable for displaying mammograms.
NASA Astrophysics Data System (ADS)
Ni, Guangming; Liu, Lin; Zhang, Jing; Liu, Juanxiu; Liu, Yong
2018-01-01
With the development of the liquid crystal display (LCD) module industry, LCD modules become more and more precise with larger sizes, which demands harsh imaging requirements for automated optical inspection (AOI). Here, we report a high-resolution and clearly focused imaging optomechatronics for precise LCD module bonding AOI inspection. It first presents and achieves high-resolution imaging for LCD module bonding AOI inspection using a line scan camera (LSC) triggered by a linear optical encoder, self-adaptive focusing for the whole large imaging region using LSC, and a laser displacement sensor, which reduces the requirements of machining, assembly, and motion control of AOI devices. Results show that this system can directly achieve clearly focused imaging for AOI inspection of large LCD module bonding with 0.8 μm image resolution, 2.65-mm scan imaging width, and no limited imaging width theoretically. All of these are significant for AOI inspection in the LCD module industry and other fields that require imaging large regions with high resolution.
LCD displays performance comparison by MTF measurement using the white noise stimulus method
NASA Astrophysics Data System (ADS)
Mitjà, Carles; Escofet, Jaume
2011-01-01
The amount of images produced to be viewed as soft copies on output displays are significantly increasing. This growing occurs at the expense of the images targeted to hard copy versions on paper or any other physical support. Even in the case of high quality hard copy production, people working in professional imaging uses different displays in selecting, editing, processing and showing images, from laptop screen to specialized high end displays. Then, the quality performance of these devices is crucial in the chain of decisions to be taken in image production. Metrics of this quality performance can help in the equipment acquisition. Different metrics and methods have been described to determine the quality performance of CRT and LCD computer displays in clinical area. One of most important metrics in this field is the device spatial frequency response obtained measuring the modulation transfer function (MTF). This work presents a comparison between the MTF of three different LCD displays, Apple MacBook Pro 15", Apple LED Cinema Display 24" and Apple iPhone4, measured by the white noise stimulus method, over vertical and horizontal directions. Additionally, different displays show particular pixels structure pattern. In order to identify this pixel structure, a set of high magnification images is taken from each display to be related with the respective vertical and horizontal MTF.
2012-12-11
ment, and difficulties creating high aspect ratio features. In addition, conventional mask-based lithography cannot create curved surfaces in the...There are three types of digital mask technologies: (1) liquid crystal display (LCD); (2) digital micromirror device (DMD); and (3) LCoS. LCD is the
Ho Huh, Yoon; Park, Byoungchoo
2015-06-23
We herein report the results of a study of a power generating reflective-type liquid crystal display (LCD), composed of a 90° twisted nematic (TN) LC cell attached to the top of a light-absorbing polymer solar cell (PSC), i.e., a Solar-LCD. The PSC consisted of a polymer bulk-heterojunction photovoltaic (PV) layer of poly[[9-(1-octylnonyl)-9H-carbazole-2,7-diyl]-2,5-thiophenediyl-2,1,3-benzothiadiazole-4,7-diyl-2,5-thiophenediyl] and [6,6]-phenyl C71 butyric acid methyl ester (PCDTBT:PCBM70), and showed a high power conversion efficiency of about 5%. In order to improve the visibility of the Solar-LCD, between the TN-LC and the PV cells we inserted a reflective polariser of a giant birefringent optical (GBO) film. The reflectivity from the Solar-LCD was observed to be considerably increased by more than 13-15% under illumination by visible light. The Solar-LCD also exhibited a significantly improved contrast ratio of more than 17-19. We believe there is a clear case for using such Solar-LCDs in new power-generating reflective-type displays; taken as a whole these results also demonstrate the possibility of their application in a number of energy-harvesting opto-electrical display devices.
Yabuuchi, Hidetake; Kawanami, Satoshi; Kamitani, Takeshi; Matsumura, Tomomi; Yamasaki, Yuzo; Morishita, Junji; Honda, Hiroshi
2017-04-01
Background Five-megapixel (MP) displays are recommended as soft copy devices for digital mammogram. An 8-MP liquid crystal display (LCD) (two 4-MP displays within one display) might offer the advantage of being able to view biplane mammography more easily than the dual planes of 5-MP LCDs. Purpose To compare detectability of Breast Imaging Reporting and Data System (BI-RADS) category 3 or higher lesions and reading time on mammography between 5- MP and 8-MP LCDs. Material and Methods The mammograms of 240 breasts of 120 patients including 60 breasts with BI-RADS category 3 or higher lesions and 180 breasts with normal or category 2 lesions were enrolled. All bilateral mammograms were displayed on bifacial 5-MP LCDs or an 8-MP LCD (two 4-MP displays within one display). Six radiologists assessed 240 breasts on each display. The observations were analyzed using receiver operating characteristic (ROC) analysis. A jack-knife method was used for statistical analysis. We employed a paired t-test to determine whether any significant differences existed in the reading time between two different displays. A P value < 0.05 was considered significant. Results The mean areas under the ROC curve obtained using 5-MP and 8-MP LCDs were 0.925 and 0.915, respectively, and there was no significant difference ( P = 0.46). There was also no significant difference in the reading time between two types of displays (57.8 min. vs. 51.5 min, P = 0.39). Conclusion The detectability of BI-RADS category 3 or higher lesions and reading time using an 8-MP LCD were comparable to those using a 5-MP LCD.
Reflective-emissive liquid-crystal displays constructed from AIE luminogens (Presentation Recording)
NASA Astrophysics Data System (ADS)
Tang, Ben Zhong; Zhao, Dongyu; Qin, Anjun
2015-10-01
The chiral nematic liquid crystal (N*-LC) has plenty of prospective applications in LC display (LCD) owing to the selective reflection and circular dichroism. The molecules in the N*-LC are aligned forming a helically twisted structure and the specific wavelength of incident light is reflected by the periodically varying refractive index in the N*-LC plane without the aid of a polarizer or color filter. However, N*-LC do not emit light which restricts its application in the dark environment. Moreover, the view angle of N*-LC display device was severe limited due to the strong viewing angle dependence of the structure color of the one dimensional photonic crystal of a N*-LC. In order to overcome these weaknesses, we have synthesized a luminescent liquid crystalline compound consisting of a tetraphenylethene (TPE) core, TPE-PPE, as a luminogen with mesogenic moieties. TPE-PPE exhibits both the aggregate-induced emission (AIE) and thermotropic liquid crystalline characteristics. By dissolving a little amount of TPE-PPE into N*-LC host, a circular polarized emission was obtained on the unidirectional orientated LC cell. Utilizing the circular polarized luminescence property of the LC mixture, we fabricated a photoluminescent liquid crystal display (PL-LCD) device which can work under both dark and sunlit conditions. This approach has simplified the device design, lowered the energy consumption and increased brightness and application of the LCD.
Video display engineering and optimization system
NASA Technical Reports Server (NTRS)
Larimer, James (Inventor)
1997-01-01
A video display engineering and optimization CAD simulation system for designing a LCD display integrates models of a display device circuit, electro-optics, surface geometry, and physiological optics to model the system performance of a display. This CAD system permits system performance and design trade-offs to be evaluated without constructing a physical prototype of the device. The systems includes a series of modules which permit analysis of design trade-offs in terms of their visual impact on a viewer looking at a display.
NASA Astrophysics Data System (ADS)
Gwag, Jin Seog; Kim, Young-Ki; Lee, Chang Hoon; Kim, Jae-Hoon
2015-06-01
Owing to the significant price drop of liquid crystal displays (LCDs) and the efforts to save natural resources, LCDs are even replacing paper to display static images such as price tags and advertising boards. Because of a growing market demand on such devices, the LCD that can be of numerous surface alignments of directors as its ground state, the so-called multi-stable LCD, comes into the limelight due to the great potential for low power consumption. However, the multi-stable LCD with industrial feasibility has not yet been successfully performed. In this paper, we propose a simple and novel configuration for the multi-stable LCD. We demonstrate experimentally and theoretically that a battery of stable surface alignments can be achieved by the field-induced surface dragging effect on an aligning layer with a weak surface anchoring. The simplicity and stability of the proposed system suggest that it is suitable for the multi-stable LCDs to display static images with low power consumption and thus opens applications in various fields.
NASA Astrophysics Data System (ADS)
McCarthy, Mitchell
The display market is presently dominated by the active matrix liquid crystal display (LCD). However, the active matrix organic light emitting diode (AMOLED) display is argued to become the successor to the LCD, and is already beginning its way into the market, mainly in small size displays. But, for AMOLED technology to become comparable in market share to LCD, larger size displays must become available at a competitive price with their LCD counterparts. A major issue preventing low-cost large AMOLED displays is the thin-film transistor (TFT) technology. Unlike the voltage driven LCD, the OLEDs in the AMOLED display are current driven. Because of this, the mature amorphous silicon TFT backplane technology used in the LCD must be upgraded to a material possessing a higher mobility. Polycrystalline silicon and transparent oxide TFT technologies are being considered to fill this need. But these technologies bring with them significant manufacturing complexity and cost concerns. Carbon nanotube enabled vertical organic field effect transistors (CN-VFETs) offer a unique solution to this problem (now known as the AMOLED backplane problem). The CN-VFET allows the use of organic semiconductors to be used for the semiconductor layer. Organics are known for their low-cost large area processing compatibility. Although the mobility of the best organics is only comparable to that of amorphous silicon, the CN-VFET makes up for this by orienting the channel vertically, as opposed to horizontally (like in conventional TFTs). This allows the CN-VFET to achieve sub-micron channel lengths without expensive high resolution patterning. Additionally, because the CN-VFET can be easily converted into a light emitting transistor (called the carbon nanotube enabled vertical organic light emitting transistor---CN-VOLET) by essentially stacking an OLED on top of the CN-VFET, more potential benefits can be realized. These potential benefits include, increased aperture ratio, increased OLED lifetime and the potential for an all transparent display. And because carbon nanotubes (CNTs) and organics are used, CN-VFET and CN-VOLET devices are compatible with flexible displays. This dissertation describes the first ever demonstration of CN-VFETs and CN-VOLETs and relates their performance to the specific properties of the CNTs and the new device architecture. In the work that followed, the CN-VFET was systematically optimized overcoming the problems revealed in the demonstration devices. The large undesired hysteresis was decreased by 96%, the on/off ratio was improved three orders of magnitude and the operating voltages were reduced to state of the art values. Additionally, the current output per device area of the CN-VFET was demonstrated to be greater than any other low resolution patterned organic transistor by a factor of 3.9. Moreover, it was demonstrated that the CNTs induce a reorientation of the high mobility plane in small molecule organics like pentacene to coincide with the vertical direction, giving additional explanation for the large currents observed in the CN-VFET. The ability to drive high currents and potentially inexpensive fabrication may provide the solution for the AMOLED backplane problem.
Ahmad, Husna Azyan Binti; El-Badawy, Ismail M; Singh, Om Prakash; Hisham, Rozana Binti; Malarvili, M B
2018-04-27
Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments. The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test. FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.
NASA Astrophysics Data System (ADS)
Debnath, Asim; Goswami, Debarghya; Mandal, Pradip Kumar
2018-04-01
Most of the liquid crystal display (LCD) devices starting from simplest wrist watches or calculators to complex laptops or flat TV sets are based on nematics. Although a tremendous improvement in the quality of display as well as reduction of manufacturing cost has taken place over the years, there are many issues which the LC industry is trying hard to address. Ferroelectric liquid crystals (FLC) are of current interest in the LCD industry since among various other advantages FLC based displays have micro-second order switching compared to milli-second order switching in nematic based displays. To meet the market demand much effort has been made to optimize the physical parameters of FLCs, such as temperature range, spontaneous polarization (PS), helical pitch (p), switching time (τ), tilt angle (θ) and rotational viscosity (γ). Multicomponent mixtures are, therefore, formulated to optimize all the required properties for practical applications since no single FLC compound can satisfy the above requirements. To the best of our knowledge electroclinic, ferroelectric and antiferroelectric liquid crystal mixtures have been formulated first time by any Indian group which have properties suitable for FLC based display devices and at par with mixtures used in the industry.
NASA Technical Reports Server (NTRS)
Marmolejo, Jose (Inventor); Smith, Stephen (Inventor); Plough, Alan (Inventor); Clarke, Robert (Inventor); Mclean, William (Inventor); Fournier, Joseph (Inventor)
1990-01-01
A helmet mounted display device is disclosed for projecting a display on a flat combiner surface located above the line of sight where the display is produced by two independent optical channels with independent LCD image generators. The display has a fully overlapped field of view on the combiner surface and the focus can be adjusted from a near field of four feet to infinity.
Digital mammography: comparative performance of color LCD and monochrome CRT displays.
Samei, Ehsan; Poolla, Ananth; Ulissey, Michael J; Lewin, John M
2007-05-01
To evaluate the comparative performance of high-fidelity liquid crystal display (LCD) and cathode ray tube (CRT) devices for mammography applications, and to assess the impact of LCD viewing angle on detection accuracy. Ninety 1 k x 1 k images were selected from a database of digital mammograms: 30 without any abnormality present, 30 with subtle masses, and 30 with subtle microcalcifications. The images were used with waived informed consent, Health Insurance Portability and Accountability Act compliance, and Institutional Review Board approval. With postprocessing presentation identical to those of the commercial mammography system used, 1 k x 1 k sections of images were viewed on a monochrome CRT and a color LCD in native grayscale, and with a grayscale representative of images viewed from a 30 degrees or 50 degrees off-normal viewing angle. Randomized images were independently scored by four experienced breast radiologists for the presence of lesions using a 0-100 grading scale. To compare diagnostic performance of the display modes, observer scores were analyzed using receiver operating characteristic (ROC) and analysis of variance. For masses and microcalcifications, the detection rate in terms of the area under the ROC curve (A(z)) showed a 2% increase and a 4% decrease from CRT to LCD, respectively. However, differences were not statistically significant (P > .05). The viewing angle data showed better microcalcification detection but lower mass detection at 30 degrees viewing orientation. The overall results varied notably from observer to observer yielding no statistically discernible trends across all observers, suggesting that within the 0-50 degrees viewing angle range and in a controlled observer experiment, the variation in the contrast response of the LCD has little or no impact on the detection of mammographic lesions. Although CRTs and LCDs differ in terms of angular response, resolution, noise, and color, these characteristics seem to have little influence on the detection of mammographic lesions. The results suggest comparable performance in clinical applications of the two devices.
LCD-based digital eyeglass for modulating spatial-angular information.
Bian, Zichao; Liao, Jun; Guo, Kaikai; Heng, Xin; Zheng, Guoan
2015-05-04
Using programmable aperture to modulate spatial-angular information of light field is well-known in computational photography and microscopy. Inspired by this concept, we report a digital eyeglass design that adaptively modulates light field entering human eyes. The main hardware includes a transparent liquid crystal display (LCD) and a mini-camera. The device analyzes the spatial-angular information of the camera image in real time and subsequently sends a command to form a certain pattern on the LCD. We show that, the eyeglass prototype can adaptively reduce light transmission from bright sources by ~80% and retain transparency to other dim objects meanwhile. One application of the reported device is to reduce discomforting glare caused by vehicle headlamps. To this end, we report the preliminary result of using the reported device in a road test. The reported device may also find applications in military operations (sniper scope), laser counter measure, STEM education, and enhancing visual contrast for visually impaired patients and elderly people with low vision.
Equivalent retarder-rotator approach to on-state twisted nematic liquid crystal displays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duran, Vicente; Lancis, Jesus; Tajahuerce, Enrique
2006-06-01
Polarization properties of a twisted nematic liquid crystal cell are fully characterized by an equivalent optical system that consists of a retarder wave plate and a rotator. In this paper we show that this result is of interest to optimize the light-modulation capabilities of a voltage-addressed liquid crystal display (LCD). We provide two examples. First, we demonstrate a calibration method that can be carried out by a standard polarimetric technique with a high degree of precision. Second, we propose an optical device to generate a family of equiazimuth polarization states by adding a quarter-wave plate to the LCD. We findmore » that the design procedure is best described in geometrical terms on the Poincare sphere by use of the equivalent model. Finally, laboratory results corresponding to a commercial LCD are presented.« less
2004-03-01
mirror device ( DMD ) for C4ISR applications, the IBM 9.2 megapixel 22-in. diagonal active matrix liquid crystal display (AMLCD) monitor for data...FED, VFD, OLED and a variety of microdisplays (uD, comprising uLCD, uOLED, DMD and other MEMs) (see glossary). 3 CDT = cathode display tubes (used in...than SVGA, greater battery life and brightness, decreased weight and thickness, electromagnetic interference (EMI), and development of video
JTEC panel on display technologies in Japan
NASA Technical Reports Server (NTRS)
Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm
1992-01-01
This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).
Amorphous Silicon: Flexible Backplane and Display Application
NASA Astrophysics Data System (ADS)
Sarma, Kalluri R.
Advances in the science and technology of hydrogenated amorphous silicon (a-Si:H, also referred to as a-Si) and the associated devices including thin-film transistors (TFT) during the past three decades have had a profound impact on the development and commercialization of major applications such as thin-film solar cells, digital image scanners and X-ray imagers and active matrix liquid crystal displays (AMLCDs). Particularly, during approximately the past 15 years, a-Si TFT-based flat panel AMLCDs have been a huge commercial success. a-Si TFT-LCD has enabled the note book PCs, and is now rapidly replacing the venerable CRT in the desktop monitor and home TV applications. a-Si TFT-LCD is now the dominant technology in use for applications ranging from small displays such as in mobile phones to large displays such as in home TV, as well-specialized applications such as industrial and avionics displays.
Thin glass substrates for mobile applications
NASA Astrophysics Data System (ADS)
Mauch, Reiner H.; Wegener, Holger; Kruse, Anke; Hildebrand, Norbert
2000-10-01
Flat panel displays play an important role as the visual interface for today's electronic devices (Notebook computers, PDA's, pagers, mobile phones, etc.). Liquid Crystal Display's are dominating the market. While for higher resolution displays active matrix displays like Thin Film Transistor LCD's are used, portable devices are mainly using Super Twisted Nematic (STN) displays. Based on the application, STN displays for mobile applications require thinner glass substrates with improved surface quality at a lower cost. The requirements and trends for STN glass substrates are identified and discussed. Different glass manufacturing processes are used today for the manufacture of these substrates. Advantages and disadvantages of the different glass substrate types are presented and discussed.
Holographic diffuser by use of a silver halide sensitized gelatin process
NASA Astrophysics Data System (ADS)
Kim, Sun Il; Choi, Yoon Sun; Ham, Yong Nam; Park, Chong Yun; Kim, Jong Man
2003-05-01
Diffusers play an important role in liquid-crystal display (LCD) application as a beam-shaping device, a brightness homogenizer, a light-scattering device, and an imaging screen. The transmittance and diffusing angle of the diffusers are the critical aspects for the applications to the LCD. The holographic diffusers by use of various processing methods have been investigated. The diffusing characteristics of different diffusing materials and processing methods have been evaluated and compared. The micro-structures of holographic diffusers have been investigated by use of using scanning electron microscopy. The holographic diffusers by use of the silver halide sensitized gelatin (SHSG) method have the structural merits for the improvement of the quality of diffusers. The features of holographic diffuser were exceptional in terms of transmittance and diffusing angle. The replication method by use of the SHSG process can be directly used for the manufacturing of diffusers for the display application.
FSC LCD technology for military and avionics applications
NASA Astrophysics Data System (ADS)
Sarma, Kalluri R.; Schmidt, John; Roush, Jerry
2009-05-01
Field sequential color (FSC) liquid crystal displays (LCD) using a high speed LCD mode and an R, G, B LED backlight, offers a significant potential for lower power consumption, higher resolution, higher brightness and lower cost compared to the conventional R, G, B color filter based LCD, and thus is of interest to various military and avionic display applications. While the DLP projection TVs, and Camcorder LCD view finder type displays using the FSC technology have been introduced in the consumer market, large area direct view LCD displays based on the FSC technology have not reached the commercial market yet. Further, large area FSC LCDs can present unique operational issues in avionic and military environments particularly for operation in a broad temperature range and with respect to its susceptibility for the color breakup image artifact. In this paper we will review the current status of the FSC LCD technology and then discuss the results of our efforts on the FSC LCD technology evaluation for the avionic applications.
Photoaligning and photopatterning technology: applications in displays and photonics
NASA Astrophysics Data System (ADS)
Chigrinov, Vladimir
2016-03-01
The advantages of LC photoalignment technology in comparison with common "rubbing" alignment methods tend to the continuation of the research in this field. Almost all the criteria of perfect LC alignment are met in case of azo-dye layers. Nowadays azo-dye alignment materials can be already used in LCD manufacturing, e.g. for the alignment of monomers in LCP films for new generations of photonics and optics devices. Recently the new application of photoaligned technology for the tunable LC lenses with a variable focal distance was proposed. New optically rewritable (ORW) liquid crystal display and photonics devices with a light controllable structure may include LC E-paper screens, LC lenses with a variable focal distance etc. Fast ferroelectric liquid crystal devices (FLCD) are achieved through the application of nano-scale photo aligning (PA) layers in FLC cells. The novel photoaligned FLC devices may include field sequential color (FSC) FLC with a high resolution, high brightness, low power consumption and extended color gamut to be used for PCs, PDAs, switchable goggles, and new generation of switchable 2D/3D LCD TVs, as well as photonics elements.
Real-Time Detection and Reading of LED/LCD Displays for Visually Impaired Persons
Tekin, Ender; Coughlan, James M.; Shen, Huiying
2011-01-01
Modern household appliances, such as microwave ovens and DVD players, increasingly require users to read an LED or LCD display to operate them, posing a severe obstacle for persons with blindness or visual impairment. While OCR-enabled devices are emerging to address the related problem of reading text in printed documents, they are not designed to tackle the challenge of finding and reading characters in appliance displays. Any system for reading these characters must address the challenge of first locating the characters among substantial amounts of background clutter; moreover, poor contrast and the abundance of specular highlights on the display surface – which degrade the image in an unpredictable way as the camera is moved – motivate the need for a system that processes images at a few frames per second, rather than forcing the user to take several photos, each of which can take seconds to acquire and process, until one is readable. We describe a novel system that acquires video, detects and reads LED/LCD characters in real time, reading them aloud to the user with synthesized speech. The system has been implemented on both a desktop and a cell phone. Experimental results are reported on videos of display images, demonstrating the feasibility of the system. PMID:21804957
Virtual reality 3D headset based on DMD light modulators
NASA Astrophysics Data System (ADS)
Bernacki, Bruce E.; Evans, Allan; Tang, Edward
2014-06-01
We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micromirror devices (DMD). Current methods for presenting information for virtual reality are focused on either polarizationbased modulators such as liquid crystal on silicon (LCoS) devices, or miniature LCD or LED displays often using lenses to place the image at infinity. LCoS modulators are an area of active research and development, and reduce the amount of viewing light by 50% due to the use of polarization. Viewable LCD or LED screens may suffer low resolution, cause eye fatigue, and exhibit a "screen door" or pixelation effect due to the low pixel fill factor. Our approach leverages a mature technology based on silicon micro mirrors delivering 720p resolution displays in a small form-factor with high fill factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high-definition resolution and low power consumption, and many of the design methods developed for DMD projector applications can be adapted to display use. Potential applications include night driving with natural depth perception, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design concept is described in which light from the DMD is imaged to infinity and the user's own eye lens forms a real image on the user's retina resulting in a virtual retinal display.
Stereoscopic display technologies for FHD 3D LCD TV
NASA Astrophysics Data System (ADS)
Kim, Dae-Sik; Ko, Young-Ji; Park, Sang-Moo; Jung, Jong-Hoon; Shestak, Sergey
2010-04-01
Stereoscopic display technologies have been developed as one of advanced displays, and many TV industrials have been trying commercialization of 3D TV. We have been developing 3D TV based on LCD with LED BLU (backlight unit) since Samsung launched the world's first 3D TV based on PDP. However, the data scanning of panel and LC's response characteristics of LCD TV cause interference among frames (that is crosstalk), and this makes 3D video quality worse. We propose the method to reduce crosstalk by LCD driving and backlight control of FHD 3D LCD TV.
Application of industrial robots in automatic disassembly line of waste LCD displays
NASA Astrophysics Data System (ADS)
Wang, Sujuan
2017-11-01
In the automatic disassembly line of waste LCD displays, LCD displays are disassembled into plastic shells, metal shields, circuit boards, and LCD panels. Two industrial robots are used to cut metal shields and remove circuit boards in this automatic disassembly line. The functions of these two industrial robots, and the solutions to the critical issues of model selection, the interfaces with PLCs and the workflows were described in detail in this paper.
Considerations in Using Computer for Presentation.
ERIC Educational Resources Information Center
Lee, Shih-chung
1997-01-01
Addresses issues to consider in conducting computer presentations. Discusses presentation devices--television, multiscan capable monitor, LCD (liquid crystal display) panel with overhead projector, and video/RGB (red, green, blue) projector; lighting; audience size; and types of presentations--fast/short time multimedia presentations, oral and…
Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture.
Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito
2017-04-01
To demonstrate the use of "Smart Puncture," a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application. A puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone's liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured. The mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased. This application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.
Full resolution hologram-like autostereoscopic display
NASA Technical Reports Server (NTRS)
Eichenlaub, Jesse B.; Hutchins, Jamie
1995-01-01
Under this program, Dimension Technologies Inc. (DTI) developed a prototype display that uses a proprietary illumination technique to create autostereoscopic hologram-like full resolution images on an LCD operating at 180 fps. The resulting 3D image possesses a resolution equal to that of the LCD along with properties normally associated with holograms, including change of perspective with observer position and lack of viewing position restrictions. Furthermore, this autostereoscopic technique eliminates the need to wear special glasses to achieve the parallax effect. Under the program a prototype display was developed which demonstrates the hologram-like full resolution concept. To implement such a system, DTI explored various concept designs and enabling technologies required to support those designs. Specifically required were: a parallax illumination system with sufficient brightness and control; an LCD with rapid address and pixel response; and an interface to an image generation system for creation of computer graphics. Of the possible parallax illumination system designs, we chose a design which utilizes an array of fluorescent lamps. This system creates six sets of illumination areas to be imaged behind an LCD. This controlled illumination array is interfaced to a lenticular lens assembly which images the light segments into thin vertical light lines to achieve the parallax effect. This light line formation is the foundation of DTI's autostereoscopic technique. The David Sarnoff Research Center (Sarnoff) was subcontracted to develop an LCD that would operate with a fast scan rate and pixel response. Sarnoff chose a surface mode cell technique and produced the world's first large area pi-cell active matrix TFT LCD. The device provided adequate performance to evaluate five different perspective stereo viewing zones. A Silicon Graphics' Iris Indigo system was used for image generation which allowed for static and dynamic multiple perspective image rendering. During the development of the prototype display, we identified many critical issues associated with implementing such a technology. Testing and evaluation enabled us to prove that this illumination technique provides autostereoscopic 3D multi perspective images with a wide range of view, smooth transition, and flickerless operation given suitable enabling technologies.
NASA Astrophysics Data System (ADS)
Starks, Michael R.
1990-09-01
A variety of low cost devices for capturing, editing and displaying field sequential 60 cycle stereoscopic video have recently been marketed by 3D TV Corp. and others. When properly used, they give very high quality images with most consumer and professional equipment. Our stereoscopic multiplexers for creating and editing field sequential video in NTSC or component(SVHS, Betacain, RGB) and Home 3D Theater system employing LCD eyeglasses have made 3D movies and television available to a large audience.
Advances in Projection Technology for On-Line Instruction.
ERIC Educational Resources Information Center
Davis, H. Scott; Miller, Marsha
This document consists of supplemental information designed to accompany a presentation on the application of projection technology, including video projectors and liquid crystal display (LCD) devices, in the online catalog library instruction program at the Indiana State University libraries. Following an introductory letter, the packet includes:…
[Analysis of color gamut of LCD system based on LED backlight with area-controlling technique].
Li, Fu-Wen; Jin, Wei-Qi; Shao, Xi-Bin; Zhang, Li-Lei; Wan, Li-Fang
2010-05-01
Color gamut as a significant performance index for display system describes the color reproduction ability IN real scenes. Liquid crystal display (LCD) is the most popular technology in flat panel display. However, conventional cold cathode fluorescent lamp (CCFL) backlight of LCD can not behave high color gamut compared with cathode ray tube (CRT). The common used method of color gamut measuring for LCD system is introduced at the beginning. According to the inner structure and display principle of LCD system, there are three major factors deciding LCD's color gamut: spectral properties of backlight, transmittance properties of color filters and performance of liquid crystal panel. Instead of conventional backlight CCFL, RGB-LED backlight is used for improving color reproduction of LCD display system. Due to the imperfect match between RGB-LED' s spectra and color filter's transmittance, the color filter would reduce the color gamut of LCD system more or less. Therefore, LCD system based on LED backlight with area-control technique is introduced which modifies backlight control signal according to the input signal After analyzing and calculating the spectra of LED backlight which passes through the color filters using method of colorimetry, the area sizes of color gamut triangles of RGB-LED backlight with area-control and RGB-LED backlight without area-control LCD systems are compared and the relationship between color gamut and varying contrast of liquid crystal panel is analyzed. It is indicated that LED backlight with area-control technique can avoid color saturation dropping and have little effects on the contrast variation of liquid crystal panel. In other words, LED backlight with area-control technique relaxes the requirements of both color filter performance and liquid crystal panel. Thus, it is of importance to improve the color gamut of the current LCD system with area-control LED backlight.
High-resolution AM LCD development for avionic applications
NASA Astrophysics Data System (ADS)
Lamberth, Larry S.; Laddu, Ravindra R.; Harris, Doug; Sarma, Kalluri R.; Li, Wang-Yang; Chien, C. C.; Chu, C. Y.; Lee, C. S.; Kuo, Chen-Lung
2003-09-01
For the first time, an avionic grade MVA AM LCD with wide viewing angle has been developed for use in either landscape or portrait mode. The development of a high resolution Multi-domain Vertical Alignment (MVA) Active Matrix Liquid Crystal Display (AM LCD) is described. Challenges met in this development include achieving the required performance with high luminance and sunlight readability while meeting stringent optical (image quality) and environmental performance requirements of avionics displays. In this paper the optical and environmental performance of this high resolution 14.1" MVA-AM-LCD are discussed and some performance comparisons to conventional AM-LCDs are documented. This AM LCD has found multiple Business Aviation and Military display applications and cockpit pictures are presented.
Ichida, Takao; Hosogai, Minoru; Yokoyama, Kouji; Ogawa, Takayoshi; Okusako, Kenji; Shougaki, Masachika; Masai, Hironao; Yamada, Eiji; Okuyama, Kazuo; Hatagawa, Masakatsu
2004-09-01
For physicians who monitor images during interventional radiology (VR), we have built and been using a system that employs a liquid crystal display (LCD) instead of the conventional cathode ray tube (CRT). The system incorporates a ceiling-suspension-type monitor (three-display monitor) with an LCD on each of the three displays for the head and abdominal regions and another ceiling-suspension-type monitor (5-display monitor) with an LCD on each display for the cardiac region. As these monitors are made to be thin and light in weight, they can be placed in a high position in the room, thereby saving space and allowing for more effective use of space in the X-ray room. The system has also improved the efficiency of operators in the IVR room. The three-display folding mechanism allows the displays to be viewed from multiple directions, thereby improving the environment so that the performance of IVR can be observed.
Development of an immersive virtual reality head-mounted display with high performance.
Wang, Yunqi; Liu, Weiqi; Meng, Xiangxiang; Fu, Hanyi; Zhang, Daliang; Kang, Yusi; Feng, Rui; Wei, Zhonglun; Zhu, Xiuqing; Jiang, Guohua
2016-09-01
To resolve the contradiction between large field of view and high resolution in immersive virtual reality (VR) head-mounted displays (HMDs), an HMD monocular optical system with a large field of view and high resolution was designed. The system was fabricated by adopting aspheric technology with CNC grinding and a high-resolution LCD as the image source. With this monocular optical system, an HMD binocular optical system with a wide-range continuously adjustable interpupillary distance was achieved in the form of partially overlapping fields of view (FOV) combined with a screw adjustment mechanism. A fast image processor-centered LCD driver circuit and an image preprocessing system were also built to address binocular vision inconsistency in the partially overlapping FOV binocular optical system. The distortions of the HMD optical system with a large field of view were measured. Meanwhile, the optical distortions in the display and the trapezoidal distortions introduced during image processing were corrected by a calibration model for reverse rotations and translations. A high-performance not-fully-transparent VR HMD device with high resolution (1920×1080) and large FOV [141.6°(H)×73.08°(V)] was developed. The full field-of-view average value of angular resolution is 18.6 pixels/degree. With the device, high-quality VR simulations can be completed under various scenarios, and the device can be utilized for simulated trainings in aeronautics, astronautics, and other fields with corresponding platforms. The developed device has positive practical significance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirata, Masaaki, E-mail: masaaki314@gmail.com; Watanabe, Ryouhei; Koyano, Yasuhiro
PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guidelinemore » while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.« less
Design of platform for removing screws from LCD display shields
NASA Astrophysics Data System (ADS)
Tu, Zimei; Qin, Qin; Dou, Jianfang; Zhu, Dongdong
2017-11-01
Removing the screws on the sides of a shield is a necessary process in disassembling a computer LCD display. To solve this issue, a platform has been designed for removing the screws on display shields. This platform uses virtual instrument technology with LabVIEW as the development environment to design the mechanical structure with the technologies of motion control, human-computer interaction and target recognition. This platform removes the screws from the sides of the shield of an LCD display mechanically thus to guarantee follow-up separation and recycle.
NASA Astrophysics Data System (ADS)
Shin, Dong-Youn; Brakke, Kenneth A.
2009-06-01
Piezo drop-on-demand inkjet printing technology has attracted the attention of display industries for the production of colour filters for thin film transistor liquid crystal displays (TFT LCD) because of the opportunity of reducing manufacturing cost. Colourant ink droplets ejected from inkjet nozzles selectively fill subpixels surrounded with black matrix (BM). Surface energy differences between the glass substrate and the BM generally guide this ink filling process. This colourant ink filling process, however, results from the complex hydrodynamic interaction of ink with the substrate and the BM. Neither computationally expensive numerical methods nor time and cost expensive experiments are suitable for the derivation of optimum surface conditions at the early development stage. In this study, a more concise surface evolution technique is proposed and ways to find the optimum surface conditions for the fabrication of TFT LCD colour filters and polymer light emitting devices are discussed, which might be useful for chemists and developers of ink and BM material, as well as for process engineers in display industries.
Image and Video Quality Assessment Using LCD: Comparisons with CRT Conditions
NASA Astrophysics Data System (ADS)
Tourancheau, Sylvain; Callet, Patrick Le; Barba, Dominique
In this paper, the impact of display on quality assessment is addressed. Subjective quality assessment experiments have been performed on both LCD and CRT displays. Two sets of still images and two sets of moving pictures have been assessed using either an ACR or a SAMVIQ protocol. Altogether, eight experiments have been led. Results are presented and discussed, some differences are pointed out. Concerning moving pictures, these differences seem to be mainly due to LCD moving artefacts such as motion blur. LCD motion blur has been measured objectively and with psycho-physics experiments. A motion-blur metric based on the temporal characteristics of LCD can be defined. A prediction model have been then designed which predict the differences of perceived quality between CRT and LCD. This motion-blur-based model enables the estimation of perceived quality on LCD with respect to the perceived quality on CRT. Technical solutions to LCD motion blur can thus be evaluated on natural contents by this mean.
Optical characterization of display screens by speckle patterns
NASA Astrophysics Data System (ADS)
Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel
2013-10-01
In recent years, flat-panel display (FPD) technology has undergone great development, and now FPDs appear in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surfaces, which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider these displays to show more vivid colors compared with matte-screen displays. However, on the glossy screens, external light sources may cause unpleasant reflections that can be reduced by a matte treatment in the front surface. In this work, we present a method to characterize FPD screens using laser-speckle patterns. We characterize three FPDs: a Samsung XL2370 LCD monitor of 23 in. with matte screen, a Toshiba Satellite A100 LCD laptop of 15.4 in. with glossy screen, and a Grammata Papyre 6.1 electronic book reader of 6 in. with ePaper screen (E-ink technology). The results show great differences in speckle-contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs that have different types of front surfaces.
Consortium for military LCD display procurement
NASA Astrophysics Data System (ADS)
Echols, Gregg
2002-08-01
International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.
Liquid crystal display (LCD) drive electronics
NASA Astrophysics Data System (ADS)
Loudin, Jeffrey A.; Duffey, Jason N.; Booth, Joseph J.; Jones, Brian K.
1995-03-01
A new drive circuit for the liquid crystal display (LCD) of the InFocus TVT-6000 video projector is currently under development at the U.S. Army Missile Command. The new circuit will allow individual pixel control of the LCD and increase the frame rate by a factor of two while yielding a major reduction in space and power requirements. This paper will discuss results of the effort to date.
On-demand stereoscopic 3D displays for avionic and military applications
NASA Astrophysics Data System (ADS)
Sarma, Kalluri; Lu, Kanghua; Larson, Brent; Schmidt, John; Cupero, Frank
2010-04-01
High speed AM LCD flat panels are evaluated for use in Field Sequential Stereoscopic (FSS) 3D displays for military and avionic applications. A 120 Hz AM LCD is used in field-sequential mode for constructing eyewear-based as well as autostereoscopic 3D display demonstrators for test and evaluation. The COTS eyewear-based system uses shutter glasses to control left-eye/right-eye images. The autostereoscopic system uses a custom backlight to generate illuminating pupils for left and right eyes. It is driven in synchronization with the images on the LCD. Both displays provide 3D effect in full-color and full-resolution in the AM LCD flat panel. We have realized luminance greater than 200 fL in 3D mode with the autostereoscopic system for sunlight readability. The characterization results and performance attributes of both systems are described.
MTF measurement of LCDs by a linear CCD imager: I. Monochrome case
NASA Astrophysics Data System (ADS)
Kim, Tae-hee; Choe, O. S.; Lee, Yun Woo; Cho, Hyun-Mo; Lee, In Won
1997-11-01
We construct the modulation transfer function (MTF) measurement system of a LCD using a linear charge-coupled device (CCD) imager. The MTF used in optical system can not describe in the effect of both resolution and contrast on the image quality of display. Thus we present the new measurement method based on the transmission property of a LCD. While controlling contrast and brightness levels, the MTF is measured. From the result, we show that the method is useful for describing of the image quality. A ne measurement method and its condition are described. To demonstrate validity, the method is applied for comparison of the performance of two different LCDs.
Diffraction phase microscopy realized with an automatic digital pinhole
NASA Astrophysics Data System (ADS)
Zheng, Cheng; Zhou, Renjie; Kuang, Cuifang; Zhao, Guangyuan; Zhang, Zhimin; Liu, Xu
2017-12-01
We report a novel approach to diffraction phase microscopy (DPM) with automatic pinhole alignment. The pinhole, which serves as a spatial low-pass filter to generate a uniform reference beam, is made out of a liquid crystal display (LCD) device that allows for electrical control. We have made DPM more accessible to users, while maintaining high phase measurement sensitivity and accuracy, through exploring low cost optical components and replacing the tedious pinhole alignment process with an automatic pinhole optical alignment procedure. Due to its flexibility in modifying the size and shape, this LCD device serves as a universal filter, requiring no future replacement. Moreover, a graphic user interface for real-time phase imaging has been also developed by using a USB CMOS camera. Experimental results of height maps of beads sample and live red blood cells (RBCs) dynamics are also presented, making this system ready for broad adaption to biological imaging and material metrology.
Switching of liquid crystal devices between reflective and transmissive modes
NASA Astrophysics Data System (ADS)
Lin, Hui-Chi; Wang, Chih-Hung
Transflective liquid crystal displays (LCD) are commonly known that each pixel is divided into reflective (R) and transmissive (T) subpixels. The R mode uses ambient light, while the T mode utilizes a backlight to display images. However, the division of the pixel decreases the light efficiency and the resolution. This study demonstrates a gelator-doped liquid crystal (LC) devices, that is switchable between R and T modes, without sub-pixel division. The R and T modes are designed to have bend configurations with phase retardation of π/2 and π, respectively. The phase retardation of a LC device can be varied and fixed by the thermoreversible association and dissociation of the gelator molecules. It is believed that the proposed device is a potential candidate for portable information systems.
Potential resource and toxicity impacts from metals in waste electronic devices.
Woo, Seung H; Lee, Dae Sung; Lim, Seong-Rin
2016-04-01
As a result of the continuous release of new electronic devices, existing electronic devices are quickly made obsolete and rapidly become electronic waste (e-waste). Because e-waste contains a variety of metals, information about those metals with the potential for substantial environmental impact should be provided to manufacturers, recyclers, and disposers to proactively reduce this impact. This study assesses the resource and toxicity (i.e., cancer, noncancer, and ecotoxicity) potentials of various heavy metals commonly found in e-waste from laptop computers, liquid-crystal display (LCD) monitors, LCD TVs, plasma TVs, color cathode ray tube (CRT) TVs, and cell phones and then evaluates such potentials using life cycle impact-based methods. Resource potentials derive primarily from Cu, Sb, Ag, and Pb. Toxicity potentials derive primarily from Pb, Ni, and Hg for cancer toxicity; from Pb, Hg, Zn, and As for noncancer toxicity; and from Cu, Pb, Hg, and Zn for ecotoxicity. Therefore, managing these heavy metals should be a high priority in the design, recycling, and disposal stages of electronic devices. © 2015 SETAC.
Mayr, Susanne; Buchner, Axel
2010-07-01
Participants performed a word-non-word discrimination task within a car control display emulated on a thin film transistor liquid-crystal display (TFT-LCD). The task simulated an information read-out from a TFT-LCD-based instrument panel. Subsequently, participants performed a low-contrast object detection task that simulated the detection of objects during night-time driving. In experiment 1, words/non-words were presented black-on-white (positive polarity) or white-on-black (negative polarity). In experiments 2 and 3, display colour was additionally manipulated. A positive polarity advantage in the discrimination task was consistently observed. In contrast, positive displays interfered more than negative displays with subsequent detection. The detrimental after-effect of positive polarity displays was strong with white and blue, reduced with amber and absent with red displays. Subjective measures showed a preference for blue over red, but a slight advantage for amber over blue. Implications for TFT-LCD design are derived from the results. STATEMENT OF RELEVANCE: When using TFT-LCDs as car instrument panels, positive polarity red TFT-LCDs are very likely to lead to good instrument readability while at the same time minimising - relative to other colours - the negative effects of an illuminated display on low-contrast object detection during night-time driving.
Image quality analysis of a color LCD as well as a monochrome LCD using a Foveon color CMOS camera
NASA Astrophysics Data System (ADS)
Dallas, William J.; Roehrig, Hans; Krupinski, Elizabeth A.
2007-09-01
We have combined a CMOS color camera with special software to compose a multi-functional image-quality analysis instrument. It functions as a colorimeter as well as measuring modulation transfer functions (MTF) and noise power spectra (NPS). It is presently being expanded to examine fixed-pattern noise and temporal noise. The CMOS camera has 9 μm square pixels and a pixel matrix of 2268 x 1512 x 3. The camera uses a sensor that has co-located pixels for all three primary colors. We have imaged sections of both a color and a monochrome LCD monitor onto the camera sensor with LCD-pixel-size to camera-pixel-size ratios of both 12:1 and 17.6:1. When used as an imaging colorimeter, each camera pixel is calibrated to provide CIE color coordinates and tristimulus values. This capability permits the camera to simultaneously determine chromaticity in different locations on the LCD display. After the color calibration with a CS-200 colorimeter the color coordinates of the display's primaries determined from the camera's luminance response are very close to those found from the CS-200. Only the color coordinates of the display's white point were in error. For calculating the MTF a vertical or horizontal line is displayed on the monitor. The captured image is color-matrix preprocessed, Fourier transformed then post-processed. For NPS, a uniform image is displayed on the monitor. Again, the image is pre-processed, transformed and processed. Our measurements show that the horizontal MTF's of both displays have a larger negative slope than that of the vertical MTF's. This behavior indicates that the horizontal MTF's are poorer than the vertical MTF's. However the modulations at the Nyquist frequency seem lower for the color LCD than for the monochrome LCD. The spatial noise of the color display in both directions is larger than that of the monochrome display. Attempts were also made to analyze the total noise in terms of spatial and temporal noise by applying subtractions of images taken at exactly the same exposure. Temporal noise seems to be significantly lower than spatial noise.
Personal graphical communicator.
Stephens, Michael; Barrett, Steven
2008-01-01
A device to help a child communicate was requested by an educator. The child cannot read, write, or speak but can recognize symbols and use those symbols to communicate. While this communication works, it doesn't work well in situations where another person does not know how to use the symbols to communicate. For this reason, a device was requested that could display images to a child and play a phrase when that image was chosen. To meet this need an MP3 player like device was constructed. The device stores images and Mpeg-Layer III (MP3) sound clips on a replaceable Secure Digital (SD) card. The images are displayed on a color Liquid Crystal Display (LCD) where the user is able to skip through images to find the phrase that needs to be said. Once found simply hitting the play button will play the sound clip associated with the image. The device is portable and compact for easy use. It uses Universal Serial Bus (USB) to recharge its batteries, communicate with the PC and update the firmware.
Lagroix, Hayley E P; Yanko, Matthew R; Spalek, Thomas M
2012-07-01
Many cognitive and perceptual phenomena, such as iconic memory and temporal integration, require brief displays. A critical requirement is that the image not remain visible after its offset. It is commonly believed that liquid crystal displays (LCD) are unsuitable because of their poor temporal response characteristics relative to cathode-ray-tube (CRT) screens. Remarkably, no psychophysical estimates of visible persistence are available to verify this belief. A series of experiments in which white stimuli on a black background produced discernible persistence on CRT but not on LCD screens, during both dark- and light-adapted viewing, falsified this belief. Similar estimates using black stimuli on a white background produced no visible persistence on either screen. That said, photometric measurements are available that seem to confirm the poor temporal characteristics of LCD screens, but they were obtained before recent advances in LCD technology. Using current LCD screens, we obtained photometric estimates of rise time far shorter (1-6 ms) than earlier estimates (20-150 ms), and approaching those of CRTs (<1 ms). We conclude that LCDs are preferable to CRTs when visible persistence is a concern, except when black-on-white displays are used.
A Feasibility Study of Real-Time Remote CT Reading for Suspected Acute Appendicitis Using an iPhone.
Kim, Changsun; Kang, Bossng; Choi, Hyuk Joong; Park, Joon Bum
2015-08-01
We aimed to evaluate the feasibility of an iPhone-based remote control system as a real-time remote computed tomography (CT) reading tool for suspected appendicitis using a third-generation (3G) network under suboptimal illumination. One hundred twenty abdominal CT scans were selected; 60 had no signs of appendicitis, whereas the remaining 60 had signs of appendicitis. The 16 raters reviewed the images using the liquid crystal display (LCD) monitor of a picture archiving and communication system (PACS) workstation, as well as using an iPhone connected to the PACS workstation via a remote control system. We graded the probability of the presence of acute appendicitis for each examination using a five-point Likert scale. The overall sensitivity and specificity for the diagnosis of suspected appendicitis using the iPhone and the LCD monitor were high, and they were not significantly different (sensitivity P = 1.00, specificity P = 0.14). The average areas under the receiver operating characteristic curves for all CT readings with the iPhone and LCD monitor were 0.978 (confidence interval 0.965-0.991) and 0.974 (0.960-0.988), respectively, and the two devices did not have significantly different diagnostic performances (P = 0.55). The inter-rater agreement for both devices was very good; the kappa value for the iPhone was 0.809 (0.793-0.826), and that for the LCD monitor was 0.817 (0.801-0.834). Each rater had moderate-to-very good intra-observer agreement between the two devices. We verified the feasibility of an iPhone-based remote control system as a real-time remote CT reading tool for identifying suspected appendicitis using a 3G network and suboptimal illumination.
Efficiency enhancement of liquid crystal projection displays using light recycle technology
NASA Technical Reports Server (NTRS)
Wang, Y.
2002-01-01
A new technology developed at JPL using low absorption color filters with polarization and color recycle system, is able to enhance efficiency of a single panel liquid crytal display (LCD) projector to the same efficiency of a 3 panel LCD projector.
Optics of twisted nematic and supertwisted nematic liquid-crystal displays
NASA Astrophysics Data System (ADS)
Leenhouts, F.; Schadt, M.
1986-11-01
For the first time calculations of the off-state transmission of twisted nematic liquid-crystal displays (LCD's) are presented which exhibit twist angles greater than the conventional 90 °. The transmission has been calculated using a treatment introduced by Priestley. In addition, the CIE (Commission Internationale d'Eclairage) color coordinates were evaluated which, together with the brightness, determine the optical appearance of an LCD. The finite efficiency of the polarizers was taken into account. The results are compared with those obtained for conventional 90 ° twisted nematic LCD's. From the calculations follow the conditions required to obtain optimal contrast and steep electro-optical characteristics in 180 ° supertwisted LCD's designed for high information content applications.
Oetjen, Sophie; Ziefle, Martina
2009-01-01
An increasing demand to work with electronic displays and to use mobile computers emphasises the need to compare visual performance while working with different screen types. In the present study, a cathode ray tube (CRT) was compared to an external liquid crystal display (LCD) and a Notebook-LCD. The influence of screen type and viewing angle on discrimination performance was studied. Physical measurements revealed that luminance and contrast values change with varying viewing angles (anisotropy). This is most pronounced in Notebook-LCDs, followed by external LCDs and CRTs. Performance data showed that LCD's anisotropy has negative impacts on completing time critical visual tasks. The best results were achieved when a CRT was used. The largest deterioration of performance resulted when participants worked with a Notebook-LCD. When it is necessary to react quickly and accurately, LCD screens have disadvantages. The anisotropy of LCD-TFTs is therefore considered to be as a limiting factor deteriorating visual performance.
Dichroic Liquid Crystal Displays
NASA Astrophysics Data System (ADS)
Bahadur, Birendra
The following sections are included: * INTRODUCTION * DICHROIC DYES * Chemical Structure * Chemical and Photochemical Stability * THEORETICAL MODELLING * DEFECTS CAUSED BY PROLONGED LIGHT IRRADIATION * CHEMICAL STRUCTURE AND PHOTOSTABILITY * OTHER PARAMETERS AFFECTING PHOTOSTABILITY * CELL PREPARATION * DICHROIC PARAMETERS AND THEIR MEASUREMENTS * Order Parameter and Dichroic Ratio Of Dyes * Absorbance, Order Parameter and Dichroic Ratio Measurements * IMPACT OF DYE STRUCTURE AND LIQUID CRYSTAL HOST ON PHYSICAL PROPERTIES OF A DICHROIC MIXTURE * Order Parameter and Dichroic Ratio * EFFECT OF LENGTH OF DICHROIC DYES ON THE ORDER PARAMETER * EFFECT OF THE BREADTH OF DYE ON THE ORDER PARAMETER * EFFECT OF THE HOST ON THE ORDER PARAMETER * TEMPERATURE VARIATION OF THE ORDER PARAMETER OF DYES IN A LIQUID CRYSTAL HOST * IMPACT OF DYE CONCENTRATION ON THE ORDER PARAMETER * Temperature Range * Viscosity * Dielectric Constant and Anisotropy * Refractive Indices and Birefringence * solubility43,153-156 * Absorption Wavelength and Auxochromic Groups * Molecular Engineering of Dichroic Dyes * OPTICAL, ELECTRO-OPTICAL AND LIFE PARAMETERS * Colour And CIE Colour space120,160-166 * CIE 1931 COLOUR SPACE * CIE 1976 CHROMATICITY DIAGRAM * CIE UNIFORM COLOUR SPACES & COLOUR DIFFERENCE FORMULAE120,160-166 * Electro-Optical Parameters120 * LUMINANCE * CONTRAST AND CONTRAST RATIO * SWITCHING SPEED * Life Parameters and Failure Modes * DICHROIC MIXTURE FORMULATION * Monochrome Mixture * Black Mixture * ACHROMATIC BLACK MIXTURE FOR HEILMEIER DISPLAYS * Effect of Illuminant on Display Colour * Colour of the Field-On State * Effect of Dye Linewidth * Optimum Centroid Wavelengths * Effect of Dye Concentration * Mixture Formulation Using More Than Three Dyes * ACHROMATIC MIXTURE FOR WHITE-TAYLOR TYPE DISPLAYS * HEILMEIER DISPLAYS * Theoretical Modelling * Threshold Characteristic * Effects of Dye Concentration on Electro-optical Parameters * Effect of Cholesteric Doping * Effect of Alignment * Effect of Thickness * Impact of Order Parameter * Impact of the Host * Impact of Polarizer * Colour Applications * Multiplexing * QUARTER WAVE PLATE DICHROIC DISPLAYS * Operational Principle and Display Configuration11-13 * Electro-Optical Performance * DYE-DOPED TN DISPLAYS * Threshold Characteristic, Contrast Ratio and Switching Speed * PHASE CHANGE EFFECT DICHROIC LCDs * Theoretical Background * Threshold Characteristic and Molecular Orientation * MOLECULAR ORIENTATION DURING FIELD-INDUCED PHASE TRANSITION WITH HOMOGENEOUS WALL ALIGNMENT * MOLECULAR ORIENTATION DURING FIELD-INDUCED PHASE TRANSITION WITH HOMEOTROPIC WALL ALIGNMENT * Contrast Ratio, Transmission, Brightness and Switching Speed3,7,10,198-214 * Memory or Reminiscent Contrast * Electro-optical Performance vs. Temperature * Multiplexing Phase Change Dichroic LCDs * DOUBLE CELL DICHROIC LCDs3,9,14-17,232-234 * Double Cell Nematic Dichroic LCD3,8,9,14,15,233 * Double Cell One Pitch Cholesteric LCD16,17 * Double Cell Phase Change Dichroic LCD214,232 * POSITIVE MODE DICHROIC LCDS3,8,9 * Positive Mode Heilmeier Cells3,8,9,43,77,78,235-238 * USING PLEOCHROIC DYES3,8,9,43,235-238 * USING NEGATIVE DICHROIC DYES3,8,9,63,77,78156 * DUAL FREQUENCY ADDRESSED DICHROIC DISPLAYS75,238 * Positive Mode Dichroic LCDs Using λ/4 Plate * Positive Mode Double Cell Dichroic LCD * Positive Mode Dichroic LCDs Using Special Electrode patterns7,8,239-241 * Positive Mode Phase Change Dichroic LCDs3,8,9,230,243-248 * Dichroic LCDs Using an Admixture of Pleochroic and Negative Dichroic Dyes78,118 * SUPERTWIST DICHROIC EFFECT (SDE) DISPLAYS21-23 * FERROELECTRIC DICHROIC LCDs24-27 * Devices Using A Single Polarizer * Devices Using No Polarizer24-27 * POLYMER DISPERSED DICHROIC LCDs28-30,252-259 * DICHROIC POLYMER LIQUID CRYSTAL DISPLAYS * Heilmeier Type Displays * Guest-Host Cell Using an Admixture Of L.C. Polymer and Low Molecular Weight Liquid Crysta As Host * Polymeric Ferroelectric Dichroic LCDs * SMECTIC A DICHROIC LCDs * Laser Addressed Dichroic SA Displays * Thermally and Electrically Addressed Dichroic SA Displays * FLUORESCENT DICHROIC LCDs * ACKNOWLEDGEMENTS * REFERENCES
Optimization of electro-optical parameters of LCD for advertising systems
NASA Astrophysics Data System (ADS)
Olifierczuk, Marek; Zielinski, Jerzy; Klosowicz, Stanislaw J.
1998-02-01
The analysis of the optimization of negative image twisted nematic LCD is presented. Theoretical considerations are confirmed by experimental results. The effect of material parameters and technology on the contrast ratio and display dynamics is given. The effect in TN display with black dye is presented.
Lin, Kae-Long
2007-09-05
In this study, we employ the following operating conditions: varied pressure (25 kgf/cm(2)), sintering temperature (900-1200 degrees C), sintering time (6h), percentage of thin film transistor liquid crystal display (TFT-LCD) waste glass by weight (0-50%) and temperature rising at a rate of 5 degrees C/min, to fabricate clay tiles. The sintering characteristics of the clay blended with TFT-LCD waste glass tiles are examined to evaluate the feasibility of the reuse of TFT-LCD waste glass. TFT-LCD waste glass contains large amounts of glass. The TCLP leaching concentrations all met the ROC EPAs current regulatory thresholds. The addition of TFT-LCD waste glass to the mixture, increased the apparent weight loss. The incorporation of 50% TFT-LCD waste glass resulted in a significant increase in the porosity ratio of the specimens compared to the porosity ratio of the ceramic tile containing TFT-LCD waste glass. The main constituent in both the clay tile and the clay with TFT-LCD waste glass samples is quartz. Increasing the temperature resulted in an increase in the flexural strength and resistance to abrasion in the tiles. The porosity ratio decreases as shrinkage increases. The relation between the porosity ratio and the hardness of the tiles used in the study is also shown.
LCD Projectors: An Evaluation of Features and Utilization for Educators.
ERIC Educational Resources Information Center
Fawson, Curtis E.
1990-01-01
Describes liquid crystal display (LCD) projectors and discusses their use in educational settings. Highlights include rear screen projection; LCD projectors currently available and the number of pixel elements in each; and examples of instructional applications, including portable setups, and use with videocassette recorders (VCRs), computers, and…
Color image quality in projection displays: a case study
NASA Astrophysics Data System (ADS)
Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter
2005-01-01
Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjovik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them therefore harder to predict.
Color image quality in projection displays: a case study
NASA Astrophysics Data System (ADS)
Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter
2004-10-01
Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjøvik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them therefore harder to predict.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokurei, Shogo, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp; Morishita, Junji, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp
Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signalsmore » for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors’ method based on the use of a commercially available color camera is useful to evaluate and understand the display performances of both monochrome and color LCDs in radiology departments.« less
2012-02-07
circuits on mechanically flexible substrates for digital, analog and radio frequency applications. The asobtained thin-film transistors ( TFTs ) exhibit... flexible substrates for digital, analog and radio frequency applications. The as- obtained thin-film transistors ( TFTs ) exhibit highly uniform device...LCD) and organic light- emitting diode ( OLED ) displays lack the transparency and flexibility and are thus unsuitable for flexible electronic
Takano, Kouji; Hata, Naoki; Kansaku, Kenji
2011-01-01
The brain–machine interface (BMI) or brain–computer interface is a new interface technology that uses neurophysiological signals from the brain to control external machines or computers. This technology is expected to support daily activities, especially for persons with disabilities. To expand the range of activities enabled by this type of interface, here, we added augmented reality (AR) to a P300-based BMI. In this new system, we used a see-through head-mount display (HMD) to create control panels with flicker visual stimuli to support the user in areas close to controllable devices. When the attached camera detects an AR marker, the position and orientation of the marker are calculated, and the control panel for the pre-assigned appliance is created by the AR system and superimposed on the HMD. The participants were required to control system-compatible devices, and they successfully operated them without significant training. Online performance with the HMD was not different from that using an LCD monitor. Posterior and lateral (right or left) channel selections contributed to operation of the AR–BMI with both the HMD and LCD monitor. Our results indicate that AR–BMI systems operated with a see-through HMD may be useful in building advanced intelligent environments. PMID:21541307
Accommodation response measurements for integral 3D image
NASA Astrophysics Data System (ADS)
Hiura, H.; Mishina, T.; Arai, J.; Iwadate, Y.
2014-03-01
We measured accommodation responses under integral photography (IP), binocular stereoscopic, and real object display conditions, and viewing conditions of binocular and monocular viewing conditions. The equipment we used was an optometric device and a 3D display. We developed the 3D display for IP and binocular stereoscopic images that comprises a high-resolution liquid crystal display (LCD) and a high-density lens array. The LCD has a resolution of 468 dpi and a diagonal size of 4.8 inches. The high-density lens array comprises 106 x 69 micro lenses that have a focal length of 3 mm and diameter of 1 mm. The lenses are arranged in a honeycomb pattern. The 3D display was positioned 60 cm from an observer under IP and binocular stereoscopic display conditions. The target was presented at eight depth positions relative to the 3D display: 15, 10, and 5 cm in front of the 3D display, on the 3D display panel, and 5, 10, 15 and 30 cm behind the 3D display under the IP and binocular stereoscopic display conditions. Under the real object display condition, the target was displayed on the 3D display panel, and the 3D display was placed at the eight positions. The results suggest that the IP image induced more natural accommodation responses compared to the binocular stereoscopic image. The accommodation responses of the IP image were weaker than those of a real object; however, they showed a similar tendency with those of the real object under the two viewing conditions. Therefore, IP can induce accommodation to the depth positions of 3D images.
NASA Astrophysics Data System (ADS)
Chen, Shu-Hsia; Wu, Shin-Tson
1992-10-01
A broad range of interdisciplinary subjects related to display technologies is addressed, with emphasis on high-definition displays, CRTs, projection displays, materials for display application, flat-panel displays, display modeling, and polymer-dispersed liquid crystals. Particular attention is given to a CRT approach to high-definition television display, a superhigh-resolution electron gun for color display CRT, a review of active-matrix liquid-crystal displays, color design for LCD parameters in projection and direct-view applications, annealing effects on ZnS:TbF3 electroluminescent devices prepared by RF sputtering, polycrystalline silicon thin film transistors with low-temperature gate dielectrics, refractive index dispersions of liquid crystals, a new rapid-response polymer-dispersed liquid-crystal material, and improved liquid crystals for active-matrix displays using high-tilt-orientation layers. (No individual items are abstracted in this volume)
Sim, L; Manthey, K; Stuckey, S
2007-06-01
A study to compare performance of the following display monitors for application as PACS CR diagnostic workstations is described. 1. Diagnostic quality, 3 Mega Pixel, 21 inch monochrome LCD monitors--Planar C3i. 2. Clinical review quality, 2 Mega Pixel, 21 inch colour LCD monitors--Planar PX212. Two sets of seventy radiological studies were presented to four senior radiologists on two occasions, using different displays on each occasion. The clinical condition used for this investigation was to query for the presence of a solitary pulmonary nodule. Receiver Operating Characteristic (ROC) curves were constructed for diagnostic performance for each presentation. Areas under the ROC curves (AUC) for diagnosis using different monitors were compared and the following results obtained: Monochrome AUC = 0.813 +/- 0.02, Colour AUC = 0.801 +/- 0.021. These results indicate that there is no statistically significant difference in the performance of these monitor types at a 95% confidence level.
Are the Color Gamuts of CRT and LCD Triangular? An Experimental Study
2000-07-01
UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADPO113 31 TITLE: Are the Color Gamuts of CRT and LCD Triangular? An...ADP011297 thru ADP011332 UNCLASSIFIED Are the Color Gamuts of CRT and LCD Triangular? An Experimental Study Guan-wei Leea and Chao-hua Wenb aDepartment of...Tube) display. This study describes the difference of color gamuts in different luminance level and the accuracy of color between CRT and LCD. In the
[The development of a respiration and temperature monitor].
Du, X; Wu, B; Liu, Y; He, Q; Xiao, J
2001-12-01
This paper introduces the design of a monitoring system to measure the respiration and temperature of a body with an 8Xc196 single-chip microcomputer. This system can measure and display the respiration wave, respiration frequency and the body temperature in real-time with a liquid crystal display (LCD) and give an alarm when the parameters are beyond the normal scope. In addition, this device can provide a 24 hours trend graph of the respiration frequency and the body temperature parameters measured. Data can also be exchanged through serial communication interfaces (RS232) between the PC and the monitor.
Research on automated disassembly technology for waste LCD
NASA Astrophysics Data System (ADS)
Qin, Qin; Zhu, Dongdong; Wang, Jingwei; Dou, Jianfang; Wang, Sujuan; Tu, Zimei
2017-11-01
In the field of Waste LCD disassembling and recycling, there are existing two major problems: 1) disassembling waste LCD mainly depends on manually mechanical crushing; 2) the resource level is not high. In order to deal with the above problems, in this paper, we develop an efficient, safe and automated waste LCD disassembling assembly line technology. This technology can disassembly and classify mainstream LCD into four components, which are liquid crystal display panels, housings and metal shield, PCB assembly. It can also disassembly many kinds of waste LCD. Compared with the traditional cooperation of manual labor and electric tools method, our proposed technology can significantly improve disassembling efficiency and demonstrate good prospects and promotional value.
Image quality evaluation of color displays using a Fovean color camera
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Dallas, William J.; Fan, Jiahua; Krupinski, Elizabeth A.; Redford, Gary R.; Yoneda, Takahiro
2007-03-01
This paper presents preliminary data on the use of a color camera for the evaluation of Quality Control (QC) and Quality Analysis (QA) of a color LCD in comparison with that of a monochrome LCD. The color camera is a C-MOS camera with a pixel size of 9 µm and a pixel matrix of 2268 × 1512 × 3. The camera uses a sensor that has co-located pixels for all three primary colors. The imaging geometry used mostly was 12 × 12 camera pixels per display pixel even though it appears that an imaging geometry of 17.6 might provide results which are more accurate. The color camera is used as an imaging colorimeter, where each camera pixel is calibrated to serve as a colorimeter. This capability permits the camera to determine chromaticity of the color LCD at different sections of the display. After the color calibration with a CS-200 colorimeter the color coordinates of the display's primaries determined from the camera's luminance response are very close to those found from the CS-200. Only the color coordinates of the display's white point were in error. Modulation Transfer Function (MTF) as well as Noise in terms of the Noise Power Spectrum (NPS) of both LCDs were evaluated. The horizontal MTFs of both displays have a larger negative slope than the vertical MTFs, indicating that the horizontal MTFs are poorer than the vertical MTFs. However the modulations at the Nyquist frequency seem lower for the color LCD than for the monochrome LCD. These results contradict simulations regarding MTFs in the vertical direction. The spatial noise of the color display in both directions are larger than that of the monochrome display. Attempts were also made to analyze the total noise in terms of spatial and temporal noise by applying subtractions of images taken at exactly the same exposure. Temporal noise seems to be significantly lower than spatial noise.
JPRS Report, Science & Technology, Optoelectronics--LCD & Related Material
1991-01-17
bottom electrode of the element are formed by the Ta film. Then, the electric field is applied in the citric acid solution and an oxide film is formed on...world, and research utilizing liquid crystal display elements and liquid crystal spatial light modulators has increased explosively . A summary of...Photographic emulsion film has been utilized in the past as the modulation device. It is regrettable but, against the two-dimensional signal, the
Low-cost, portable open-source gas monitoring device based on chemosensory technology
NASA Astrophysics Data System (ADS)
Gotor, Raúl; Gaviña, Pablo; Costero, Ana M.
2015-08-01
We report herein the construction of an electronic device to perform the real-time digitalization of the color state of the optical chemosensors used in the detection of dangerous gases. To construct the device, we used open-source modular electronics, such as Arduino and Sparkfun components, as well as free and open-source software (FOSS). The basic principle of the operation of this device is the continuous color measurement of a chemosensor-doped sensing film, whose color changes in the presence of a specific gas. The chemosensor-sensing film can be prepared by using any of the widely available chemosensors for the desired gas. Color measurement is taken by two TCS230 color sensor ICs, reported to the microcontroller, and the results are displayed on an LCD display and pushed through a USB serial port. By using a cyanide optical chemosensor, we demonstrated the operation of the device as a HCN gas detector at low concentrations.
Universal design of a microcontroller and IoT system to detect the heart rate
NASA Astrophysics Data System (ADS)
Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar
2017-11-01
Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).
Atmospheric plasma generation for LCD panel cleaning
NASA Astrophysics Data System (ADS)
Kim, Gyu-Sik; Won, Chung-Yuen; Choi, Ju-Yeop; Yim, C. H.
2007-12-01
UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-barrier discharges (DBDs), also referred to as barrier discharges or silent discharges have for a long time been exclusively related to ozone generation. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The -phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, bi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.
Influence of the set-up on the recording of diffractive optical elements into photopolymers
NASA Astrophysics Data System (ADS)
Gallego, S.; Fernández, R.; Márquez, A.; Neipp, C.; Beléndez, A.; Pascual, I.
2014-05-01
Photopolymers are often used as a base of holographic memories displays. Recently the capacity of photopolymers to record diffractive optical elements (DOE's) has been demonstrated. To fabricate diffractive optical elements we use a hybrid setup that is composed by three different parts: LCD, optical system and the recording material. The DOE pattern is introduced by a liquid crystal display (LCD) working in the amplitude only mode to work as a master to project optically the DOE onto the recording material. The main advantage of this display is that permit us modify the DOE automatically, we use the electronics of the video projector to send the voltage to the pixels of the LCD. The LCD is used in the amplitude-mostly modulation regime by proper orientation of the external polarizers (P); then the pattern is imaged onto the material with an increased spatial frequency (a demagnifying factor of 2) by the optical system. The use of the LCD allows us to change DOE recorded in the photopolymer without moving any mechanical part of the set-up. A diaphragm is placed in the focal plane of the relay lens so as to eliminate the diffraction orders produced by the pixelation of the LCD. It can be expected that the final pattern imaged onto the recording material will be low filtered due to the finite aperture of the imaging system and especially due to the filtering process produced by the diaphragm. In this work we analyze the effect of the visibility achieved with the LCD and the high frequency cut-off due to the diaphragm in the final DOE recorded into the photopolymer. To simulate the recording we have used the fitted values parameters obtained for PVA/AA based photopolymers and the 3 dimensional models presented in previous works.
NASA Astrophysics Data System (ADS)
Lim, E. K.; Norizan, M. N.; Mohamad, I. S.; Yasin, M. N. M.; Murad, S. A. Z.; Baharum, N. A.; Jamalullail, N.
2017-09-01
This paper presents the design of anti-theft/cable cut real time alert system using microcontroller and GSM technology. The detection part is using the electrical circuit wire connection in detecting the voltage drop of the cable inside the microcontroller digital input port. The GSM wireless modem is used to send the location of cable cut directly to the authority mobile phone. Microcontroller SK40C with Microchip PIC16F887 is used as a controller to control the wireless modem and also the detection device. The device is able to detect and display the location of the cable cut on the LCD display besides of and sending out the location of the cable break to the authority mobile phone wirelessly via SMS.
Active-matrix OLED using 150°C a-Si TFT backplane built on flexible plastic substrate
NASA Astrophysics Data System (ADS)
Sarma, Kalluri R.; Chanley, Charles; Dodd, Sonia R.; Roush, Jared; Schmidt, John; Srdanov, Gordana; Stevenson, Matthew; Wessel, Ralf; Innocenzo, Jeffrey; Yu, Gang; O'Regan, Marie B.; MacDonald, W. A.; Eveson, R.; Long, Ke; Gleskova, Helena; Wagner, Sigurd; Sturm, James C.
2003-09-01
Flexible displays fabricated using plastic substrates have a potential for being very thin, light weight, highly rugged with greatly minimized propensity for breakage, roll-to-roll manufacturing and lower cost. The emerging OLED display media offers the advantage of being a solid state and rugged structure for flexible displays in addition to the many potential advantages of an AM OLED over the currently dominant AM LCD. The current high level of interest in flexible displays is facilitating the development of the required enabling technologies which include development of plastic substrates, low temperature active matrix device and backplane fabrication, and display packaging. In the following we will first discuss our development efforts in the PEN based plastic substrates, active matrix backplane technology, low temperature (150°C) a-Si TFT devices and an AM OLED test chip used for evaluating various candidate designs. We will then describe the design, fabrication and successful evaluation and demonstration of a 64x64 pixel AM OLED test display using a-Si TFT backplane fabricated at 150°C on the flexible plastic substrate.
Achromatic diffractive lens written onto a liquid crystal display.
Márquez, A; Iemmi, C; Campos, J; Yzuel, M J
2006-02-01
We propose a programmable diffractive lens written onto a liquid crystal display (LCD) that is able to provide equal focal lengths for several wavelengths simultaneously. To achieve this goal it is necessary that the LCD operate in the phase-only regime simultaneously for the different wavelengths. We design the appropriate lens for each wavelength, and then the lenses are spatially multiplexed onto the LCD. Various multiplexing schemes have been analyzed, and the random scheme shows the best performance. We further show the possibility of finely tuning the chromaticity of the focal spot by changing the relative weights of the multiplexing among the various wavelengths.
An electron transporting blue emitter for OLED
NASA Astrophysics Data System (ADS)
Qi, Boyuan; Luo, Jiaxiu; Li, Suyue; Xiao, Lixin; Sun, Wenfang; Chen, Zhijian; Qu, Bo; Gong, Qihuang
2010-11-01
After the premier commercialization of OLED in 1997, OLED has been considered as the candidate for the next generation of flat panel display. In comparison to liquid crystal display (LCD) and plasma display panel (PDP), OLED exhibits promising merits for display, e.g., flexible, printable, micro-buildable and multiple designable. Although many efforts have been made on electroluminescent (EL) materials and devices, obtaining highly efficient and pure blue light is still a great challenge. In order to improve the emission efficiency and purity of the blue emission, a new bipolar blue light emitter, 2,7-di(2,2':6',2"-terpyridine)- 2,7-diethynyl-9,9-dioctyl-9H-fluorene (TPEF), was designed and synthesized. A blue OLED was obtained with the configuration of ITO/PEDOT/PVK:CBP:TPEF/LiF/Al. The device exhibits a turn-on voltage of 9 V and a maximum brightness of 12 cd/m2 at 15 V. The device gives a deep blue emission located at 420 nm with the Commission Internationale de l'Eclairage (CIE) coordinates of (0.17, 0.10). We also use TPEF as electron transporting material in the device of ITO/PPV/TPEF/LiF/Al, the turn-on voltage is 3 V. It is proved the current in the device was enhanced indeed by using the new material.
Chen, T K; Chen, J N
2004-01-01
In TFT-LCD industry, water plays a variety of roles as a cleaning agent and reaction solvent. As good quality water is increasingly a scarce resource and wastewater treatment costs rises, the once-through use of industrial water is becoming uneconomical and environmentally unacceptable. Instead, recycling of TFT-LCD industrial wastewater is become more attractive from both an economic and environmental perspective. This research is mainly to explore the capacity of TFT-LCD industrial wastewater recycling by the process combined with membrane bioreactor and reverse osmosis processes. Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 97.3%. For TOC and BOD5 items, the average removal efficiencies were 97.8 and 99.4% respectively. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of the UF membrane device incorporated with biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After treatment of RO, excellent water quality of permeate were under 5 mg/l, 2.5 mg/l and 150 micros/cm for COD, TOC and conductivity respectively. The treated water can be recycled for the cooling tower make-up water or other purposes.
The Eyephone: a head-mounted stereo display
NASA Astrophysics Data System (ADS)
Teitel, Michael A.
1990-09-01
Head mounted stereo displays for virtual environments and computer simulations have been made since 1969. Most of the recent displays have been based on monochrome (black and white) liquid crystal display technology. Color LCD displays have generally not been used due to their lower resolution and color triad structure. As the resolution of color LCDdisplays is increasing we have begun to use color displays in our Eyephone. In this paper we describe four methods for minimizing the effect of the color triads in the magnified images of LCD displays in the Eyephone stereo head mounted display. We have settled on the use of wavefront randomizer with a spatial frequency enhancement overlay in order to blur the triacis in the displays while keeping the perceived resolution of the display high.
Three-dimensional image display system using stereogram and holographic optical memory techniques
NASA Astrophysics Data System (ADS)
Kim, Cheol S.; Kim, Jung G.; Shin, Chang-Mok; Kim, Soo-Joong
2001-09-01
In this paper, we implemented a three dimensional image display system using stereogram and holographic optical memory techniques which can store many images and reconstruct them automatically. In this system, to store and reconstruct stereo images, incident angle of reference beam must be controlled in real time, so we used BPH (binary phase hologram) and LCD (liquid crystal display) for controlling reference beam. And input images are represented on the LCD without polarizer/analyzer for maintaining uniform beam intensities regardless of the brightness of input images. The input images and BPHs are edited using application software with having the same recording scheduled time interval in storing. The reconstructed stereo images are acquired by capturing the output images with CCD camera at the behind of the analyzer which transforms phase information into brightness information of images. The reference beams are acquired by Fourier transform of BPH which designed with SA (simulated annealing) algorithm, and represented on the LCD with the 0.05 seconds time interval using application software for reconstructing the stereo images. In output plane, we used a LCD shutter that is synchronized to a monitor that displays alternate left and right eye images for depth perception. We demonstrated optical experiment which store and reconstruct four stereo images in BaTiO3 repeatedly using holographic optical memory techniques.
An improved method for LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; Wang, Qiaojie; He, Nannan; Ye, Yushan
2018-03-01
The colorimetric characterization of the display can achieve the purpose of precisely controlling the color of the monitor. This paper describes an improved method for estimating the gamma value of liquid-crystal displays (LCDs) without using a measurement device was described by Xiao et al. It relies on observer's luminance matching by presenting eight half-tone patterns with luminance from 1/9 to 8/9 of the maximum value of each color channel. Since the previous method lacked partial low frequency information, we partially replaced the half-tone patterns. A large number of experiments show that the color difference is reduced from 3.726 to 2.835, and our half-tone pattern can better estimate the visual gamma value of LCDs.
Current status of stereoscopic 3D LCD TV technologies
NASA Astrophysics Data System (ADS)
Choi, Hee-Jin
2011-06-01
The year 2010 may be recorded as a first year of successful commercial 3D products. Among them, the 3D LCD TVs are expected to be the major one regarding the sales volume. In this paper, the principle of current stereoscopic 3D LCD TV techniques and the required flat panel display (FPD) technologies for the realization of them are reviewed. [Figure not available: see fulltext.
Benedetto, Simone; Drai-Zerbib, Véronique; Pedrotti, Marco; Tissier, Geoffrey; Baccino, Thierry
2013-01-01
The mass digitization of books is changing the way information is created, disseminated and displayed. Electronic book readers (e-readers) generally refer to two main display technologies: the electronic ink (E-ink) and the liquid crystal display (LCD). Both technologies have advantages and disadvantages, but the question whether one or the other triggers less visual fatigue is still open. The aim of the present research was to study the effects of the display technology on visual fatigue. To this end, participants performed a longitudinal study in which two last generation e-readers (LCD, E-ink) and paper book were tested in three different prolonged reading sessions separated by - on average - ten days. Results from both objective (Blinks per second) and subjective (Visual Fatigue Scale) measures suggested that reading on the LCD (Kindle Fire HD) triggers higher visual fatigue with respect to both the E-ink (Kindle Paperwhite) and the paper book. The absence of differences between E-ink and paper suggests that, concerning visual fatigue, the E-ink is indeed very similar to the paper. PMID:24386252
Integrated IMA (Information Mission Areas) IC (Information Center) Guide
1989-06-01
COMPUTER AIDED DESIGN / COMPUTER AIDED MANUFACTURE 8-8 8.3.7 LIQUID CRYSTAL DISPLAY PANELS 8-8 8.3.8 ARTIFICIAL INTELLIGENCE APPLIED TO VI 8-9 8.4...2 10.3.1 DESKTOP PUBLISHING 10-3 10.3.2 INTELLIGENT COPIERS 10-5 10.3.3 ELECTRONIC ALTERNATIVES TO PRINTED DOCUMENTS 10-5 10.3.4 ELECTRONIC FORMS...Optical Disk LCD Units Storage Image Scanners Graphics Forms Output Generation Copiers Devices Software Optical Disk Intelligent Storage Copiers Work Group
Projection display industry market and technology trends
NASA Astrophysics Data System (ADS)
Castellano, Joseph A.; Mentley, David E.
1995-04-01
The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.
Generation of helical Ince-Gaussian beams with a liquid-crystal display.
Bentley, Joel B; Davis, Jeffrey A; Bandres, Miguel A; Gutiérrez-Vega, Julio C
2006-03-01
We generate helical Ince-Gaussian (HIG) beams by using complex amplitude and phase masks encoded onto a liquid-crystal display (LCD). These beams display an intensity pattern consisting of elliptic rings, whose number and ellipticity can be controlled, and a phase exhibiting a number of in-line vortices, each with a unitary topological charge. We show experimental results that display the properties of these elliptic dark hollow beams. We introduce a novel interference technique for generating the object and reference beams by using a single LCD and show the vortex interference patterns. We expect that these HIG beams will be useful in optical trapping applications.
Generation of helical Ince-Gaussian beams with a liquid-crystal display
NASA Astrophysics Data System (ADS)
Bentley, Joel B.; Davis, Jeffrey A.; Bandres, Miguel A.; Gutiérrez-Vega, Julio C.
2006-03-01
We generate helical Ince-Gaussian (HIG) beams by using complex amplitude and phase masks encoded onto a liquid-crystal display (LCD). These beams display an intensity pattern consisting of elliptic rings, whose number and ellipticity can be controlled, and a phase exhibiting a number of in-line vortices, each with a unitary topological charge. We show experimental results that display the properties of these elliptic dark hollow beams. We introduce a novel interference technique for generating the object and reference beams by using a single LCD and show the vortex interference patterns. We expect that these HIG beams will be useful in optical trapping applications.
A flexible optically re-writable color liquid crystal display
NASA Astrophysics Data System (ADS)
Zhang, Yihong; Sun, Jiatong; Liu, Yang; Shang, Jianhua; Liu, Hao; Liu, Huashan; Gong, Xiaohui; Chigrinov, Vladimir; Kowk, Hoi Sing
2018-03-01
It is very difficult to make a liquid crystal display (LCD) that is flexible. However, for an optically re-writable LCD (ORWLCD), only the spacers and the substrates need to be flexible because the driving unit and the display unit are separate and there are no electronics in the display part of ORWLCD. In this paper, three flexible-spacer methods are proposed to achieve this goal. A cholesteric liquid crystal colored mirror with a polarizer behind it is used as the colored reflective backboard of an ORWLCD. Polyethersulfone substrates and flexible spacers are used to make the optically re-writable cell insensitive to mechanical force.
State of the art of fine patterned Si TFT
NASA Astrophysics Data System (ADS)
Noguchi, Takashi
2003-05-01
Performance and relating subject for fine patterned Si TFT (Thin Film Transistor) are reviewed and discussed from a viewpoint of device and/or fabrication process based on reported results. Poly-Si TFTs fabricated on glass using low-temperature process are studied extensively for the application to LCD (Liquid Crystal Display) or OLED (Organic Light Emitting Diode) Display. Currently, the research target for the TFT application is emphasized on the highly functional system on glass or the display on flexible substrate by adopting an effective crystallizing technique of SPC (Solid Phase Crystallization) or ELC (Excimer Laser Crystallization). Improvement of device characteristics such as an enhancement of carrier mobility has been studied intensively by enlarging the grain size. Reduction of the voltage and shrinkage of the device size are the trend of Si LSI, which arise a peculiar issue of uniformity or an anisotropy problem for the device characteristics in the large grained poly-Si film. Some trial approaches for solving the issues such as nucleation control for the grain growth or lateral grain growth are proposed, so far. By overcoming the issues, coming SOP (System on Panel) era using the Si TFTs is expected.
Design of a handheld infrared imaging device based on uncooled infrared detector
NASA Astrophysics Data System (ADS)
Sun, Xianzhong; Li, Junwei; Zhang, Yazhou
2017-02-01
This paper, we introduced the system structure and operation principle of the device, and discussed our solutions for image data acquisition and storage, operating states and modes control and power management in detail. Besides, we proposed a algorithm of pseudo color for thermal image and applied it to the image processing module of the device. The thermal images can be real time displayed in a 1.8 inches TFT-LCD. The device has a compacted structure and can be held easily by one hand. It also has a good imaging performance with low power consumption, thermal sensitivity is less than 150mK. At last, we introduced one of its applications for fault diagnosis in electronic circuits, the test shows that: it's a good solution for fast fault detection.
Batteryless magneto-driven portable radiac
Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Wolf, M.A.; Umbarger, C.J.
1984-10-19
A hand-powerd alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Mueller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.
Batteryless magneto-driven portable radiac
Waechter, David A.; Bjarke, George O.; Trujillo, Faustin; Wolf, Michael A.; Umbarger, C. John
1986-01-01
A hand-powered alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Muller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.
NASA Astrophysics Data System (ADS)
Wang, Jun; Min, Kyeong-Yuk; Chong, Jong-Wha
2010-11-01
Overdrive is commonly used to reduce the liquid-crystal response time and motion blur in liquid-crystal displays (LCDs). However, overdrive requires a large frame memory in order to store the previous frame for reference. In this paper, a high-compression-ratio codec is presented to compress the image data stored in the on-chip frame memory so that only 1 Mbit of on-chip memory is required in the LCD overdrives of mobile devices. The proposed algorithm further compresses the color bitmaps and representative values (RVs) resulting from the block truncation coding (BTC). The color bitmaps are represented by a luminance bitmap, which is further reduced and reconstructed using median filter interpolation in the decoder, while the RVs are compressed using adaptive quantization coding (AQC). Interpolation and AQC can provide three-level compression, which leads to 16 combinations. Using a rate-distortion analysis, we select the three optimal schemes to compress the image data for video graphics array (VGA), wide-VGA LCD, and standard-definitionTV applications. Our simulation results demonstrate that the proposed schemes outperform interpolation BTC both in PSNR (by 1.479 to 2.205 dB) and in subjective visual quality.
The use of the liquid crystal display (LCD) panel as a teaching aid in medical lectures.
Wong, K T
1992-01-01
The liquid crystal display (LCD) panel is designed to project on-screen information of a microcomputer onto a larger screen with the aid of a standard overhead projector, so that large audiences may view on-screen information without having to crowd around the TV monitor. As little has been written about its use as a visual aid in medical teaching, the present report documents its use in a series of pathology lectures delivered, over a 2-year period, to two classes of about 150 medical students each. Some advantages of the LCD panel over the 35mm slide include the flexibility of last-minute text changes and less lead time needed for text preparation. It eliminates the problems of messy last-minute changes in, and improves legibility of, handwritten overhead projector transparencies. The disadvantages of using an LCD panel include the relatively bulky equipment which may pose transport problems, image clarity that is inferior to the 35mm slide, and equipment costs.
Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya
2017-06-01
The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.
Confocal retinal imaging using a digital light projector with a near infrared VCSEL source
NASA Astrophysics Data System (ADS)
Muller, Matthew S.; Elsner, Ann E.
2018-02-01
A custom near infrared VCSEL source has been implemented in a confocal non-mydriatic retinal camera, the Digital Light Ophthalmoscope (DLO). The use of near infrared light improves patient comfort, avoids pupil constriction, penetrates the deeper retina, and does not mask visual stimuli. The DLO performs confocal imaging by synchronizing a sequence of lines displayed with a digital micromirror device to the rolling shutter exposure of a 2D CMOS camera. Real-time software adjustments enable multiply scattered light imaging, which rapidly and cost-effectively emphasizes drusen and other scattering disruptions in the deeper retina. A separate 5.1" LCD display provides customizable visible stimuli for vision experiments with simultaneous near infrared imaging.
Liquid crystal television custom drive circuit
NASA Astrophysics Data System (ADS)
Loudin, Jeffrey A.
1994-03-01
A new drive circuit for the liquid crystal display (LCD) of the InFocus TVT-6000TM video projector is currently under development at the U.S. Army Missile Command. The new circuit will allow individual pixel control of the LCD. This paper will discuss results of the effort to date.
Correa, John B; Apolzan, John W; Shepard, Desti N; Heil, Daniel P; Rood, Jennifer C; Martin, Corby K
2016-07-01
Activity monitors such as the Actical accelerometer, the Sensewear armband, and the Intelligent Device for Energy Expenditure and Activity (IDEEA) are commonly validated against gold standards (e.g., doubly labeled water, or DLW) to determine whether they accurately measure total daily energy expenditure (TEE) or activity energy expenditure (AEE). However, little research has assessed whether these parameters or others (e.g., posture allocation) predict body weight change over time. The aims of this study were to (i) test whether estimated energy expenditure or posture allocation from the devices was associated with weight change during and following a low-calorie diet (LCD) and (ii) compare free-living TEE and AEE predictions from the devices against DLW before weight change. Eighty-seven participants from 2 clinical trials wore 2 of the 3 devices simultaneously for 1 week of a 2-week DLW period. Participants then completed an 8-week LCD and were weighed at the start and end of the LCD and 6 and 12 months after the LCD. More time spent walking at baseline, measured by the IDEEA, significantly predicted greater weight loss during the 8-week LCD. Measures of posture allocation demonstrated medium effect sizes in their relationships with weight change. Bland-Altman analyses indicated that the Sensewear and the IDEEA accurately estimated TEE, and the IDEEA accurately measured AEE. The results suggest that the ability of energy expenditure and posture allocation to predict weight change is limited, and the accuracy of TEE and AEE measurements varies across activity monitoring devices, with multi-sensor monitors demonstrating stronger validity.
Correa, John B.; Apolzan, John W.; Shepard, Desti N.; Heil, Daniel P.; Rood, Jennifer C.; Martin, Corby K.
2016-01-01
Activity monitors such as the Actical accelerometer, the Sensewear armband, and the Intelligent Device for Energy Expenditure and Activity (IDEEA) are commonly validated against gold standards (e.g., doubly labeled water, or DLW) to determine whether they accurately measure total daily energy expenditure (TEE) or activity energy expenditure (AEE). However, little research has assessed whether these parameters or others (e.g., posture allocation) predict body weight change over time. The aims of this study were to (i) test whether estimated energy expenditure or posture allocation from the devices was associated with weight change during and following a low-calorie diet (LCD) and (ii) compare free-living TEE and AEE predictions from the devices against DLW before weight change. Eighty-seven participants from 2 clinical trials wore 2 of the 3 devices simultaneously for 1 week of a 2-week DLW period. Participants then completed an 8-week LCD and were weighed at the start and end of the LCD and 6 and 12 months after the LCD. More time spent walking at baseline, measured by the IDEEA, significantly predicted greater weight loss during the 8-week LCD. Measures of posture allocation demonstrated medium effect sizes in their relationships with weight change. Bland–Altman analyses indicated that the Sensewear and the IDEEA accurately estimated TEE, and the IDEEA accurately measured AEE. The results suggest that the ability of energy expenditure and posture allocation to predict weight change is limited, and the accuracy of TEE and AEE measurements varies across activity monitoring devices, with multi-sensor monitors demonstrating stronger validity. PMID:27270210
Market trends in the projection display industry
NASA Astrophysics Data System (ADS)
Dash, Sweta
2001-03-01
The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection TV segment. Rear LCD (liquid crystal display), MEMS/DLP (or Digital Light Processing TM) and LCOS (Liquid-crystal-on-silicon) TVs are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are also facing challenges from LCD and DLP technology for the home theater market while the business market is completely dominated by front LCD and DLP technology. Three-chip DLP projectors have replaced liquid crystal light valves in large venue applications where projectors have higher light output requirements. In recent years front LCD and LCOS projectors have been increasingly competing with 3-chip DLP projectors especially at the low end of the large venue application market. Within the next five years the projection market will experience very fast growth. Sales and presentation applications, which are the fastest growing applications in the business market, will continue to be the major driving force for the growth for front projectors, and the shift in the consumer market to digital and HDTV products will drive the rear projection market.
Muramoto, Hideyuki; Shimamoto, Kazuhiro; Ikeda, Mitsuru; Koyama, Kazuyuki; Fukushima, Hiromichi; Ishigaki, Takeo
2006-06-01
The influence of monitor brightness and room illumination on soft-copy diagnosis by both cathode-ray tube (CRT) monitor and liquid crystal display (LCD) was evaluated and compared using a contrast-detail phantom. Nine observers (7 radiologists and 2 radiological technicians) interpreted six types of electronically generated contrast-detail phantom images using a 21-inch CRT (2,048x2,560) and a 21-inch LCD (2,048x2,560) under 6 kinds of viewing conditions, i.e. monitor brightness of 330 cd/m2 or 450 cd/m2, and room illumination of 20, 100 or 420 lux at the center of the display. Observers were requested to determine the visible borderline of the objects. Between 330 cd/m2 and 450 cd/m2, no significant difference in the visible area was found under any of the three lighting conditions. However, in two low-contrast phantom images, the visible area on the LCD was significantly larger than that on the CRT, independent of both monitor brightness and room illumination. (p<0.05). The effect of room illumination was not significant, suggesting that the use of LCD at high room illumination is acceptable.
Analysis of Crosstalk in 3D Circularly Polarized LCDs Depending on the Vertical Viewing Location.
Zeng, Menglin; Nguyen, Truong Q
2016-03-01
Crosstalk in circularly polarized (CP) liquid crystal display (LCD) with polarized glasses (passive 3D glasses) is mainly caused by two factors: 1) the polarizing system including wave retarders and 2) the vertical misalignment (VM) of light between the LC module and the patterned retarder. We show that the latter, which is highly dependent on the vertical viewing location, is a much more significant factor of crosstalk in CP LCD than the former. There are three contributions in this paper. Initially, a display model for CP LCD, which accurately characterizes VM, is proposed. A novel display calibration method for the VM characterization that only requires pictures of the screen taken at four viewing locations. In addition, we prove that the VM-based crosstalk cannot be efficiently reduced by either preprocessing the input images or optimizing the polarizing system. Furthermore, we derive the analytic solution for the viewing zone, where the entire screen does not have the VM-based crosstalk.
Illumination system for a projector composed of three LCD panels
NASA Astrophysics Data System (ADS)
Ho, Fang C.; Chu, Cheng-Wei; Lee, William
2004-10-01
A novel compound prism device consisting of a cubic polarizing beam splitter (PBS) and a non-polarizing dichroic prism is configured as the core component of the illumination unit of a full color projection display system of three pieces of reflective type liquid crystal imaging panels. When the in-coming light beam impinging on the PBS at 45 deg. of incidence, the beam component polarized perpendicularly to the plane of incidence is reflected and directed toward a LCD panel of red-image signal addressed after transmitted through a red-passing dichroic filter. The beam component polarized in parallel with the plane of incidence of the PBS is transmitted and passing through a red-cut dichroic filter. The rest portion of the light beam is then got the blue and green color bands separated by the dichroic filter at 30 deg. of incidence and directed to a blue and green signal addressed LCD panel respectively. All the dichroic filters are designed polarization independent and the PBS has a high contrast ratio of 1000 for the on/off states of teh addressed pixels of the image panels. The color separation and re-combination prism unit will provide a screen uniformity of d(u',v') <0.01 when it is accomodated in the projector with a projection lens assembly of F/#2.4.
Park, Joon Bum; Choi, Hyuk Joong; Lee, Jeong Hun; Kang, Bo Seung
2013-08-01
We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage by the iPad 2 and the clinical liquid crystal display (LCD) monitor. We selected 100 brain CT exams performed for head trauma or headache. Fifty had subtle radiological signs of intracranial hemorrhage (ICH), while the other 50 showed no significant abnormality. Five emergency medicine physicians reviewed these brain CT scans using the iPad 2 and the LCD monitor, scoring the probability of ICH on each exam on a five-point scale. Result showed high sensitivities and specificities in both devices. We generated receiver operating characteristic curves and calculated the average area under the curve of the iPad 2 and the LCD (0.935 and 0.900). Using the iPad 2 and reliable internet connectivity, clinicians can provide remote evaluation of brain CT with subtle hemorrhage under suboptimal viewing condition. Considering the distinct advantages of the iPad 2, the popular out-of-hospital use of mobile CT teleradiology would be anticipated soon.
Optical fringe-reflection deflectometry with bundle adjustment
NASA Astrophysics Data System (ADS)
Xiao, Yong-Liang; Li, Sikun; Zhang, Qican; Zhong, Jianxin; Su, Xianyu; You, Zhisheng
2018-06-01
Liquid crystal display (LCD) screens are located outside of a camera's field of view in fringe-reflection deflectometry. Therefore, fringes that are displayed on LCD screens are obtained through specular reflection by a fixed camera. Thus, the pose calibration between the camera and LCD screen is one of the main challenges in fringe-reflection deflectometry. A markerless planar mirror is used to reflect the LCD screen more than three times, and the fringes are mapped into the fixed camera. The geometrical calibration can be accomplished by estimating the pose between the camera and the virtual image of fringes. Considering the relation between their pose, the incidence and reflection rays can be unified in the camera frame, and a forward triangulation intersection can be operated in the camera frame to measure three-dimensional (3D) coordinates of the specular surface. In the final optimization, constraint-bundle adjustment is operated to refine simultaneously the camera intrinsic parameters, including distortion coefficients, estimated geometrical pose between the LCD screen and camera, and 3D coordinates of the specular surface, with the help of the absolute phase collinear constraint. Simulation and experiment results demonstrate that the pose calibration with planar mirror reflection is simple and feasible, and the constraint-bundle adjustment can enhance the 3D coordinate measurement accuracy in fringe-reflection deflectometry.
Past and future challenges from a display mask writer perspective
NASA Astrophysics Data System (ADS)
Ekberg, Peter; von Sydow, Axel
2012-06-01
Since its breakthrough, the liquid crystal technology has continued to gain momentum and the LCD is today the dominating display type used in desktop monitors, television sets, mobile phones as well as other mobile devices. To improve production efficiency and enable larger screen sizes, the LCD industry has step by step increased the size of the mother glass used in the LCD manufacturing process. Initially the mother glass was only around 0.1 m2 large, but with each generation the size has increased and with generation 10 the area reaches close to 10 m2. The increase in mother glass size has in turn led to an increase in the size of the photomasks used - currently the largest masks are around 1.6 × 1.8 meters. A key mask performance criterion is the absence of "mura" - small systematic errors captured only by the very sensitive human eye. To eliminate such systematic errors, special techniques have been developed by Micronic Mydata. Some mura suppressing techniques are described in this paper. Today, the race towards larger glass sizes has come to a halt and a new race - towards higher resolution and better image quality - is ongoing. The display mask is therefore going through a change that resembles what the semiconductor mask went through some time ago: OPC features are introduced, CD requirements are increasing sharply and multi tone masks (MTMs) are widely used. Supporting this development, Micronic Mydata has introduced a number of compensation methods in the writer, such as Z-correction, CD map and distortion control. In addition, Micronic Mydata MMS15000, the world's most precise large area metrology tool, has played an important role in improving mask placement quality and is briefly described in this paper. Furthermore, proposed specifications and system architecture concept for a new generation mask writers - able to fulfill future image quality requirements - is presented in this paper. This new system would use an AOD/AOM writing engine and be capable of resolving 0.6 micron features.
Imaging dynamic and selective low-complexity domain interactions that control gene transcription.
Chong, Shasha; Dugast-Darzacq, Claire; Liu, Zhe; Dong, Peng; Dailey, Gina M; Cattoglio, Claudia; Heckert, Alec; Banala, Sambashiva; Lavis, Luke; Darzacq, Xavier; Tjian, Robert
2018-06-21
Many eukaryotic transcription factors (TFs) contain intrinsically disordered low-complexity domains (LCDs), but how they drive transactivation remains unclear. Here, live-cell single-molecule imaging reveals that TF-LCDs form local high-concentration interaction hubs at synthetic and endogenous genomic loci. TF-LCD hubs stabilize DNA binding, recruit RNA polymerase II (Pol II), and activate transcription. LCD-LCD interactions within hubs are highly dynamic, display selectivity with binding partners, and are differentially sensitive to disruption by hexanediols. Under physiological conditions, rapid and reversible LCD-LCD interactions occur between TFs and the Pol II machinery without detectable phase separation. Our findings reveal fundamental mechanisms underpinning transcriptional control and suggest a framework for developing single-molecule imaging screens for novel drugs targeting gene regulatory interactions implicated in disease. Copyright © 2018, American Association for the Advancement of Science.
NASA Astrophysics Data System (ADS)
Ito, Shusei; Uchida, Keitaro; Mizushina, Haruki; Suyama, Shiro; Yamamoto, Hirotsugu
2017-02-01
Security is one of the big issues in automated teller machine (ATM). In ATM, two types of security have to be maintained. One is to secure displayed information. The other is to secure screen contamination. This paper gives a solution for these two security issues. In order to secure information against peeping at the screen, we utilize visual cryptography for displayed information and limit the viewing zone. Furthermore, an aerial information screen with aerial imaging by retro-reflection, named AIRR enables users to avoid direct touch on the information screen. The purpose of this paper is to propose an aerial secure display technique that ensures security of displayed information as well as security against contamination problem on screen touch. We have developed a polarization-processing display that is composed of a backlight, a polarizer, a background LCD panel, a gap, a half-wave retarder, and a foreground LCD panel. Polarization angle is rotated with the LCD panels. We have constructed a polarization encryption code set. Size of displayed images are designed to limit the viewing position. Furthermore, this polarization-processing display has been introduced into our aerial imaging optics, which employs a reflective polarizer and a retro-reflector covered with a quarter-wave retarder. Polarization-modulated light forms the real image over the reflective polarizer. We have successfully formed aerial information screen that shows the secret image with a limited viewing position. This is the first realization of aerial secure display by use of polarization-processing display with retarder-film and retro-reflector.
Global industry status report and roadmap for high performance displays
NASA Astrophysics Data System (ADS)
Bardsley, J. Norman; Pinnel, M. Robert
2003-09-01
A summary is provided of a comprehensive industry status report and roadmap available from www.usdc.org. Continued improvements in LCD technology are being driven by home entertainment applications, leading to better color and video response. Competing technologies, such as PDP and OLED and electronic paper must either exploit inherent advantages for such applications or focus on other market niches that are not being addressed well by mainline LCD technology. Flexible displays provide an opportunity for innovative technologies and manufacturing methods, but appear to bring no killer applications.
Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain
2015-12-01
Display (LCD) Screen Thermal Testing to Simulate Solar Gain 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6 . AUTHOR(S) Steven...Sunlight, Monitor Screen Covered 9 2.6 Test 6 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass 9 2.7 Test 7 – Bench Test with a 250 W Heat...that was used. The use of a black background with white text was important in creating the worst-case scenario for the absorption of solar radiation
Characterization and optimization of 3D-LCD module design
NASA Astrophysics Data System (ADS)
van Berkel, Cees; Clarke, John A.
1997-05-01
Autostereoscopic displays with flat panel liquid crystal display and lenticular sheets are receiving much attention. Multiview 3D-LCD is truly autostereoscopic because no head tracking is necessary and the technology is well poised to become a mass market consumer 3D display medium as the price of liquid crystal displays continues to drop. Making the viewing experience as natural as possible is of prime importance. The main challenges are to reduce the picket fence effect of the black mask and to try to get away with as few perspective views as possible. Our solution is to 'blur' the boundaries between the views. This hides the black mask image by spreading it out and softens the transition between one view and the next, encouraging the user to perceive 'solid objects' instead of a succession of flipping views. One way to achieve this is by introducing a new pixel design in which the pixels are slanted with respect to the column direction. Another way is to place the lenticular at a small (9.46 degree) angle with respect to the LCD columns. The effect of either method is that, as the observer moves sideways in front of the display, he always 'sees' a constant amount of black mask. This renders the black mask, in effect, invisible and eliminates the picket fence effect.
Ethernet based data logger for gaseous detectors
NASA Astrophysics Data System (ADS)
Swain, S.; Sahu, P. K.; Sahu, S. K.
2018-05-01
A data logger is designed to monitor and record ambient parameters such as temperature, pressure and relative humidity along with gas flow rate as a function of time. These parameters are required for understanding the characteristics of gas-filled detectors such as Gas Electron Multiplier (GEM) and Multi-Wire Proportional Counter (MWPC). The data logger has different microcontrollers and has been interfaced to an ethernet port with a local LCD unit for displaying all measured parameters. In this article, the explanation of the data logger design, hardware, and software description of the master microcontroller and the DAQ system along with LabVIEW interface client program have been presented. We have implemented this device with GEM detector and displayed few preliminary results as a function of above parameters.
Confocal Retinal Imaging Using a Digital Light Projector with a Near Infrared VCSEL Source
Muller, Matthew S.; Elsner, Ann E.
2018-01-01
A custom near infrared VCSEL source has been implemented in a confocal non-mydriatic retinal camera, the Digital Light Ophthalmoscope (DLO). The use of near infrared light improves patient comfort, avoids pupil constriction, penetrates the deeper retina, and does not mask visual stimuli. The DLO performs confocal imaging by synchronizing a sequence of lines displayed with a digital micromirror device to the rolling shutter exposure of a 2D CMOS camera. Real-time software adjustments enable multiply scattered light imaging, which rapidly and cost-effectively emphasizes drusen and other scattering disruptions in the deeper retina. A separate 5.1″ LCD display provides customizable visible stimuli for vision experiments with simultaneous near infrared imaging. PMID:29899586
Fast response liquid crystal devices
NASA Astrophysics Data System (ADS)
Wu, Yung-Hsun
Liquid crystal (LC) has been widely used for displays, spatial light modulators, variable optical attenuators (VOAs) and other tunable photonic devices. The response time of these devices is mainly determined by the employed liquid crystal material. The response time of a LC device depends on the visco-elastic coefficient (gamma1/K11), LC cell gap (d), and applied voltage. Hence, low visco-elastic coefficient LC materials and thinner cell gap are favorable for reducing the response time. However, low visco-elastic coefficient LCs are usually associated with a low birefringence because of shorter molecular conjugation. For display applications, such as LCD TVs, low birefringence (Deltan<0.1) LCs are commonly used. However, for optical communications at 1550 nm, low birefringence requires to a thick cell gap which, in turn, increases the response time. How to obtain fast response for the LC devices is a fundamentally important and technically challenging task. In this dissertation, we investigate several methods to improve liquid crystal response time, for examples, using dual-frequency liquid crystals, polymer stabilized liquid crystals, and sheared polymer network liquid crystals. We discover a new class of material, denoted as sheared polymer network liquid crystal (SPNLC) which exhibits a submillisecond response time. Moreover, this response time is insensitive to the LC cell gap. This is the first LC device exhibiting such an interesting property. Chapters 1 and 2 describe the motivation and background of this dissertation. From chapter 3 to chapter 6, dual-frequency liquid crystals and polymer network methods are demonstrated as examples for the variable optical attenuators. Variable optical attenuator (VOA) is a key component in optical communications. Especially, the sheared PNLC VOA shows the best result; its dynamic range reaches 43 dB while the response time is in the submillisecond range at 1550 nm wavelength, which is 50 times faster than the commercial LC-based VOA. In Chapter 7, we report a new device called axially-symmetric sheared polymer network liquid crystals (AS-SPNLC) and use it as LC devices. Through analyzing the structure of this axially-symmetric SPNLC, we construct a 3-D model to explain the observed phenomena. An axially-symmetric sheared polymer network liquid crystal has several attractive features: (1) it is polarization independent, (2) it has gradient phase change, and (3) its response time is fast. It can be used for polarization converter and divergent LC lens. In addition, a new method for simultaneously measuring the phase retardation and optic axis of a compensation film is demonstrated using an axially-symmetric sheared polymer network liquid crystal. By overlaying a tested compensation film with a calibrated SPNLC cell between crossed polarizers, the optic axis and phase retardation value of the compensation film can be determined. This simple technique can be used for simultaneously measuring the optic axis and phase retardations of both A- and C-plates. These compensation films have been used extensively in wide-view LCD industry. Therefore, this method will make an important impact to the LCD industry.
LCD real-time mask technique for fabrication of arbitrarily shaped microstructure
NASA Astrophysics Data System (ADS)
Peng, Qinjun; Guo, Yongkang; Chen, Bo; Du, Jinglei; Xiang, Jinshan; Cui, Zheng
2002-04-01
A new technique to fabricate arbitrarily shaped microstructures by using LCD (liquid crystal display) real- time mask is reported in this paper. Its principle and design method are explained. Based on partial coherent imaging theory, the process to fabricate micro-axicon array and zigzag grating has been simulated. The experiment using a color LCD as real-time mask has been set up. Micro-axicon array and zigzag grating has been fabricated by the LCD real-time mask technique. The 3D surface relief structures were made on pan chromatic silver-halide sensitized gelatin (Kodak-131) with trypsinase etching. The pitch size of zigzag grating is 46.26micrometers . The caliber of axicon is 118.7micrometers , and the etching depth is 1.332micrometers .
Liu, Yi-Hung; Chen, Yan-Jen
2011-01-01
Defect detection has been considered an efficient way to increase the yield rate of panels in thin film transistor liquid crystal display (TFT-LCD) manufacturing. In this study we focus on the array process since it is the first and key process in TFT-LCD manufacturing. Various defects occur in the array process, and some of them could cause great damage to the LCD panels. Thus, how to design a method that can robustly detect defects from the images captured from the surface of LCD panels has become crucial. Previously, support vector data description (SVDD) has been successfully applied to LCD defect detection. However, its generalization performance is limited. In this paper, we propose a novel one-class machine learning method, called quasiconformal kernel SVDD (QK-SVDD) to address this issue. The QK-SVDD can significantly improve generalization performance of the traditional SVDD by introducing the quasiconformal transformation into a predefined kernel. Experimental results, carried out on real LCD images provided by an LCD manufacturer in Taiwan, indicate that the proposed QK-SVDD not only obtains a high defect detection rate of 96%, but also greatly improves generalization performance of SVDD. The improvement has shown to be over 30%. In addition, results also show that the QK-SVDD defect detector is able to accomplish the task of defect detection on an LCD image within 60 ms. PMID:22016625
Liu, Yi-Hung; Chen, Yan-Jen
2011-01-01
Defect detection has been considered an efficient way to increase the yield rate of panels in thin film transistor liquid crystal display (TFT-LCD) manufacturing. In this study we focus on the array process since it is the first and key process in TFT-LCD manufacturing. Various defects occur in the array process, and some of them could cause great damage to the LCD panels. Thus, how to design a method that can robustly detect defects from the images captured from the surface of LCD panels has become crucial. Previously, support vector data description (SVDD) has been successfully applied to LCD defect detection. However, its generalization performance is limited. In this paper, we propose a novel one-class machine learning method, called quasiconformal kernel SVDD (QK-SVDD) to address this issue. The QK-SVDD can significantly improve generalization performance of the traditional SVDD by introducing the quasiconformal transformation into a predefined kernel. Experimental results, carried out on real LCD images provided by an LCD manufacturer in Taiwan, indicate that the proposed QK-SVDD not only obtains a high defect detection rate of 96%, but also greatly improves generalization performance of SVDD. The improvement has shown to be over 30%. In addition, results also show that the QK-SVDD defect detector is able to accomplish the task of defect detection on an LCD image within 60 ms.
Use of Linear and Circular Polarization: The Secret LCD Screen and 3D Cinema
ERIC Educational Resources Information Center
Richtberg, Stefan; Girwidz, Raimund
2017-01-01
References to everyday life are important for teaching physics. Discussing polarization phenomena, liquid crystal displays (LCDs) and 3D cinemas provide such references. In this paper we describe experiments to support students' understanding of linearly polarized light as well as the phenomenon of inverted colors using a secret LCD screen.…
A Dynamic Competition Simulation for Worldwide Big-size TV Market Using Lotka-Volterra Model
NASA Astrophysics Data System (ADS)
Chen, Wu-Tung Terry; Li, Yiming; Hung, Chih-Young
2009-08-01
Technological innovation is characterized by the substitution of new technologies for full-fledged ones in the development of new products, processes and techniques. Global TV market is seeing a price down-spiral for FPD(Flat Panel Display)-TVs, replacement of CRT by LCD, and consumer's defection to larger screen. The LCD-TV market started in Japan from 2003 and took off globally from 2005. LCD panel production is moving toward larger sizes. In the 35″-39″ size market, the price/performance ratio of LCD-TV is better than that of PDP. The purpose of this paper is to estimate the demand function of worldwide big-size (35″-39″) TVs including LCD and PDP with an explicit consideration of market competition. The demand function was estimated using Lotka-Volterra model, a famous competitive diffusion model. The results exhibit a kind of predator-prey relationship, in which the PDP market was hunted by LCD product. In addition, the coefficients of difference equations of Lotka-Volterra model in this analysis are also used to forecast the future market of the big-size LCD and PDP.
Recent progress in liquid crystal projection displays
NASA Astrophysics Data System (ADS)
Hamada, Hiroshi
1997-05-01
An LC-projector usually contains 3 monochrome TFT-LCDs with a 3-channel dichroic system or a single TFT-LCD with a micro color filter. The liquid crystal operation mode adopted in a TFT-LCD is TN. The optical throughput of an LC-projector is reduced by a pair of polarizers, an aperture ratio of a TFT- LCD and a color filter in a single-LCD projector. In order to eliminate absorption loss by a color filter, a single LCD projection system which consists of a monochrome LCD with a microlens array and a color splitting system using tilted dichroic mirrors or another optical element such as a holographic optical element or a blazed grating has been developed. And LC rear projection TVs have started to challenge CRT-based rear projection TVs. In addition to this system, new technologies to improve optical throughput have been developed to the practical stage such as an active- matrix-addressed PDLC and a reflective type LCD on a Si-LSI chip. Merits and technical issues of newly developed systems and conventional systems including a-Si TFT-LCDs and p-Si TFT-LCDs are discussed mainly in terms of optical throughput.
Reflective and transflective liquid crystal displays
NASA Astrophysics Data System (ADS)
Zhou, Fushan
Recently transflective liquid crystal displays (LCD) received a lot of attention. A transflective display has a transmissive mode and a reflective mode. It combines the high contrast, high brightness of the transmissive mode with energy-saving of reflective mode and has good performance in various illumination conditions. However, state-of-the-art transflective displays have problems such as different electro-optical properties, difficulty in compatibility and optimization of both modes, low efficiency of light utilization, and complexity in structure. This dissertation focuses on finding new designs of transflective displays that address those problems. One way to do this is to study film compensation of LCD. We first studied film compensation of bistable twisted nematic (BTN) LCD. Starting form the reduced (3x3) Mueller matrices, we derived and simplified the conditions that film compensated BTN can be optimized. Based on these relations, electro-optical properties of some particular configurations, and designs of transflective BTN with high brightness and contrast were given. To confirm and get a better understanding of the results, we use the Poincare sphere to analyze film compensated BTN. The key to this approach is the existence of "fixed points". Compared with the matrix approach, this approach is more simple, elegant, and efficient. We then generalized the Poincare sphere approach to a universal approach of LCD. We applied the universal approach to film compensation of ECB and IPS, and the design of achromatic birefringent filters. We also give two more new designs of transflective displays. In the first design, a dichroic mirror is used to split the visible spectrum into two parts used in transmissive and reflective modes, respectively. Both modes can be optimized. It has a simple structure and good light utilization. A design for a full-color transflective display with good performance is also given. In the second design, each pixel is divided into two sub-pixels, a transmissive one and a reflective one. By using polymer stabilization, the birefringence of the transmissive sub-pixels is twice that of the reflective ones. The display has single cell gap, low driving voltage, fast response, high contrast and brightness, and the transmissive and reflective modes are synchronized.
LCD blink effect: acoustic specific or widespread phenomenon
NASA Astrophysics Data System (ADS)
Wright, Graham; Bosko, Floyd; Allen, Steve; Thomas, John T.
2000-08-01
The problem of 'flicker' of data presented on large area LCDs is deemed to be a major problem by the military display user community. Although the problem is certainly applicable to the display of certain types of acoustics data there are those who would expand it to cover datatypes which do not suffer from the effect. This paper describes in some detail the mechanisms within the LCD that cause the problem and extrapolates scenarios where compensation is required and where it would be redundant or detrimental. Solutions, which might be used to eliminate the effect are also described.
Research on effects of phase error in phase-shifting interferometer
NASA Astrophysics Data System (ADS)
Wang, Hongjun; Wang, Zhao; Zhao, Hong; Tian, Ailing; Liu, Bingcai
2007-12-01
Referring to phase-shifting interferometry technology, the phase shifting error from the phase shifter is the main factor that directly affects the measurement accuracy of the phase shifting interferometer. In this paper, the resources and sorts of phase shifting error were introduction, and some methods to eliminate errors were mentioned. Based on the theory of phase shifting interferometry, the effects of phase shifting error were analyzed in detail. The Liquid Crystal Display (LCD) as a new shifter has advantage as that the phase shifting can be controlled digitally without any mechanical moving and rotating element. By changing coded image displayed on LCD, the phase shifting in measuring system was induced. LCD's phase modulation characteristic was analyzed in theory and tested. Based on Fourier transform, the effect model of phase error coming from LCD was established in four-step phase shifting interferometry. And the error range was obtained. In order to reduce error, a new error compensation algorithm was put forward. With this method, the error can be obtained by process interferogram. The interferogram can be compensated, and the measurement results can be obtained by four-step phase shifting interferogram. Theoretical analysis and simulation results demonstrate the feasibility of this approach to improve measurement accuracy.
Digital cinema system using JPEG2000 movie of 8-million pixel resolution
NASA Astrophysics Data System (ADS)
Fujii, Tatsuya; Nomura, Mitsuru; Shirai, Daisuke; Yamaguchi, Takahiro; Fujii, Tetsuro; Ono, Sadayasu
2003-05-01
We have developed a prototype digital cinema system that can store, transmit and display extra high quality movies of 8-million pixel resolution, using JPEG2000 coding algorithm. The image quality is 4 times better than HDTV in resolution, and enables us to replace conventional films with digital cinema archives. Using wide-area optical gigabit IP networks, cinema contents are distributed and played back as a video-on-demand (VoD) system. The system consists of three main devices, a video server, a real-time JPEG2000 decoder, and a large-venue LCD projector. All digital movie data are compressed by JPEG2000 and stored in advance. The coded streams of 300~500 Mbps can be continuously transmitted from the PC server using TCP/IP. The decoder can perform the real-time decompression at 24/48 frames per second, using 120 parallel JPEG2000 processing elements. The received streams are expanded into 4.5Gbps raw video signals. The prototype LCD projector uses 3 pieces of 3840×2048 pixel reflective LCD panels (D-ILA) to show RGB 30-bit color movies fed by the decoder. The brightness exceeds 3000 ANSI lumens for a 300-inch screen. The refresh rate is chosen to 96Hz to thoroughly eliminate flickers, while preserving compatibility to cinema movies of 24 frames per second.
Color enhancement for portable LCD displays in low-power mode
NASA Astrophysics Data System (ADS)
Shih, Kuang-Tsu; Huang, Tai-Hsiang; Chen, Homer H.
2011-09-01
Switching the backlight of handheld devices to low power mode saves energy but affects the color appearance of an image. In this paper, we consider the chroma degradation problem and propose an enhancement algorithm that incorporates the CIECAM02 appearance model to quantitatively characterize the problem. In the proposed algorithm, we enhance the color appearance of the image in low power mode by weighted linear superposition of the chroma of the image and that of the estimated dim-backlight image. Subjective tests are carried out to determine the perceptually optimal weighting and prove the effectiveness of our framework.
Research on starlight hardware-in-the-loop simulator
NASA Astrophysics Data System (ADS)
Zhang, Ying; Gao, Yang; Qu, Huiyang; Liu, Dongfang; Du, Huijie; Lei, Jie
2016-10-01
The starlight navigation is considered to be one of the most important methods for spacecraft navigation. Starlight simulation system is a high-precision system with large fields of view, designed to test the starlight navigation sensor performance on the ground. A complete hardware-in-the-loop simulation of the system has been built. The starlight simulator is made up of light source, light source controller, light filter, LCD, collimator and control computer. LCD is the key display component of the system, and is installed at the focal point of the collimator. For the LCD cannot emit light itself, so light source and light source power controller is specially designed for the brightness demanded by the LCD. Light filter is designed for the dark background which is also needed in the simulation.
Investigation of ITO free transparent conducting polymer based electrode
NASA Astrophysics Data System (ADS)
Sharma, Vikas; Sapna, Sachdev, Kanupriya
2016-05-01
The last few decades have seen a significant improvement in organic semiconductor technology related to solar cell, light emitting diode and display panels. The material and structure of the transparent electrode is one of the major concerns for superior performance of devices such as OPV, OLED, touch screen and LCD display. Commonly used ITO is now restricted due to scarcity of indium, its poor mechanical properties and rigidity, and mismatch of energy levels with the active layer. Nowadays DMD (dielectric-metal-dielectric) structure is one of the prominent candidates as alternatives to ITO based electrode. We have used solution based spin coated polymer layer as the dielectric layer with silver thin film embedded in between to make a polymer-metal-polymer (PMP) structure for TCE applications. The PMP structure shows low resistivity (2.3 x 10-4Ω-cm), high carrier concentration (2.9 x 1021 cm-3) and moderate transparency. The multilayer PMP structure is characterized with XRD, AFM and Hall measurement to prove its suitability for opto-electronic device applications.
iPads and LCDs show similar performance in the detection of pulmonary nodules
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Lowe, Joanna; Butler, Marie Louise; Pietrzyk, Mariusz; Evanoff, Michael G.; Ryan, John; Brennan, Patrick C.; Rainford, Louise A.
2012-02-01
In February 2011 the University of Chicago Medical School distributed iPads to its trainee doctors for use when reviewing clinical information and images on the ward or clinics. The use of tablet computing devices is becoming widespread in medicine with Apple™ heralding them as "revolutionary" in medicine. The question arises, just because it is technical achievable to use iPads for clinical evaluation of images, should we do so? The current work assesses the diagnostic efficacy of iPads when compared with LCD secondary display monitors for identifying lung nodules on chest x-rays. Eight examining radiologists of the American Board of Radiology were involved in the assessment, reading chest images on both the iPad and the an off-the-shelf LCD monitor. Thirty chest images were shown to each observer, of which 15 had one or more lung nodules. Radiologists were asked to locate the nodules and score how confident they were with their decision on a scale of 1-5. An ROC and JAFROC analysis was performed and modalities were compared using DBM MRMC. The results demonstrate no significant differences in performance between the iPad and the LCD for the ROC AUC (p<0.075) or JAFROC FOM (p<0.059) for random readers and random cases. Sample size estimation showed that this result is significant at a power of 0.8 and an effect size of 0.05 for ROC and 0.07 for JAFROC. This work demonstrates that for the task of identifying pulmonary nodules, the use of the iPad does not significantly change performance compared to an off-the-shelf LCD.
NASA Astrophysics Data System (ADS)
Bentley, Joel B.; Davis, Jeffrey A.; Albero, Jorge; Moreno, Ignacio
2006-10-01
We report a new self-interferometric technique for visualizing phase patterns that are encoded onto a phase-only liquid-crystal display (LCD). In our approach, the LCD generates both the desired object beam as well as the reference beam. Normally the phase patterns are encoded with a phase depth of 2π radians, and all of the incident energy is diffracted into the first-order beam. However, by reducing this phase depth, we can generate an additional zero-order diffracted beam, which acts as the reference beam. We work at distances such that these two patterns spatially interfere, producing an interference pattern that displays the encoded phase pattern. This approach was used recently to display the phase vortices of helical Ince-Gaussian beams. Here we show additional experimental results and analyze the process.
A portable device for rapid nondestructive detection of fresh meat quality
NASA Astrophysics Data System (ADS)
Lin, Wan; Peng, Yankun
2014-05-01
Quality attributes of fresh meat influence nutritional value and consumers' purchasing power. In order to meet the demand of inspection department for portable device, a rapid and nondestructive detection device for fresh meat quality based on ARM (Advanced RISC Machines) processor and VIS/NIR technology was designed. Working principal, hardware composition, software system and functional test were introduced. Hardware system consisted of ARM processing unit, light source unit, detection probe unit, spectral data acquisition unit, LCD (Liquid Crystal Display) touch screen display unit, power unit and the cooling unit. Linux operating system and quality parameters acquisition processing application were designed. This system has realized collecting spectral signal, storing, displaying and processing as integration with the weight of 3.5 kg. 40 pieces of beef were used in experiment to validate the stability and reliability. The results indicated that prediction model developed using PLSR method using SNV as pre-processing method had good performance, with the correlation coefficient of 0.90 and root mean square error of 1.56 for validation set for L*, 0.95 and 1.74 for a*,0.94 and 0.59 for b*, 0.88 and 0.13 for pH, 0.79 and 12.46 for tenderness, 0.89 and 0.91 for water content, respectively. The experimental result shows that this device can be a useful tool for detecting quality of meat.
Autostereoscopic display technology for mobile 3DTV applications
NASA Astrophysics Data System (ADS)
Harrold, Jonathan; Woodgate, Graham J.
2007-02-01
Mobile TV is now a commercial reality, and an opportunity exists for the first mass market 3DTV products based on cell phone platforms with switchable 2D/3D autostereoscopic displays. Compared to conventional cell phones, TV phones need to operate for extended periods of time with the display running at full brightness, so the efficiency of the 3D optical system is key. The desire for increased viewing freedom to provide greater viewing comfort can be met by increasing the number of views presented. A four view lenticular display will have a brightness five times greater than the equivalent parallax barrier display. Therefore, lenticular displays are very strong candidates for cell phone 3DTV. Selection of Polarisation Activated Microlens TM architectures for LCD, OLED and reflective display applications is described. The technology delivers significant advantages especially for high pixel density panels and optimises device ruggedness while maintaining display brightness. A significant manufacturing breakthrough is described, enabling switchable microlenses to be fabricated using a simple coating process, which is also readily scalable to large TV panels. The 3D image performance of candidate 3DTV panels will also be compared using autostereoscopic display optical output simulations.
A PDA-based electrocardiogram/blood pressure telemonitor for telemedicine.
Bolanos, Marcos; Nazeran, Homayoun; Gonzalez, Izzac; Parra, Ricardo; Martinez, Christopher
2004-01-01
An electrocardiogram (ECG) / blood pressure (BP) telemonitor consisting of comprehensive integration of various electrical engineering concepts, devices, and methods was developed. This personal digital assistant-based (PDAbased) system focused on integration of biopotential amplifiers, photoplethysmographic measurement of blood pressure, microcontroller devices, programming methods, wireless transmission, signal filtering and analysis, interfacing, and long term memory devices (24 hours) to develop a state-of-the-art ECG/BP telemonitor. These instrumentation modules were developed and tested to realize a complete and compact system that could be deployed to assist in telemedicine applications and heart rate variability studies. The specific objective of this device was to facilitate the long term monitoring and recording of ECG and blood pressure signals. This device was able to acquire ECG/BP waveforms, transmit them wirelessly to a PDA, save them onto a compact flash memory, and display them on the LCD screen of the PDA. It was also capable of calculating the heart rate (HR) in beats per minute, and providing systolic and diastolic blood pressure values.
A design of the u-health monitoring system using a Nintendo DS game machine.
Lee, Sangjoon; Kim, Jinkwon; Kim, Jungkuk; Lee, Myoungho
2009-01-01
In this paper, we used the hand held type a Nintendo DS Game Machine for consisting of a u-Health Monitoring system. This system is consists of four parts. Biosignal acquire device is the first. The Second is a wireless sensor network device. The third is a wireless base-station for connecting internet network. Displaying units are the last part which were a personal computer and a Nintendo DS game machine. The bio-signal measurement device among the four parts the u-health monitoring system can acquire 7-channels data which have 3-channels ECG(Electrocardiogram), 3-axis accelerometer and tilting sensor data. Acquired data connect up the internet network throughout the wireless sensor network and a base-station. In the experiment, we concurrently display the bio-signals on to a monitor of personal computer and LCD of a Nintendo DS using wireless internet protocol and those monitoring devices placed off to the one side an office building. The result of the experiment, this proposed system effectively can transmit patient's biosignal data as a long time and a long distance. This suggestion of the u-health monitoring system need to operate in the ambulance, general hospitals and geriatric institutions as a u-health monitoring device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chacko, M; Aldoohan, S
Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended undermore » simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.« less
Lei, Tim C.; Pendyala, Srinivas; Scherrer, Larry; Li, Buhong; Glazner, Gregory F.; Huang, Zheng
2016-01-01
Recent clinical reports suggest that overexposure to light emissions generated from cathode ray tube (CRT) and liquid crystal display (LCD) color monitors after topical or systemic administration of a photosensitizer could cause noticeable skin phototoxicity. In this study, we examined the light emission profiles (optical irradiance, spectral irradiance) of CRT and LCD monitors under simulated movie and video game modes. Results suggest that peak emissions and integrated fluence generated from monitors are clinically relevant and therefore prolonged exposure to these light sources at a close distance should be avoided after the administration of a photosensitizer or phototoxic drug. PMID:23669681
Generation of helical Ince-Gaussian beams: beam-shaping with a liquid crystal display
NASA Astrophysics Data System (ADS)
Davis, Jeffrey A.; Bentley, Joel B.; Bandres, Miguel A.; Gutiérrez-Vega, Julio C.
2006-08-01
We review the three types of laser beams - Hermite-Gaussian (HG), Laguerre-Gaussian (LG) and the newly discovered Ince-Gaussian (IG) beams. We discuss the helical forms of the LG and IG beams that consist of linear combinations of the even and odd solutions and form a number of vortices that are useful for optical trapping applications. We discuss how to generate these beams by encoding the desired amplitude and phase onto a single parallel-aligned liquid crystal display (LCD). We introduce a novel interference technique where we generate both the object and reference beams using a single LCD and show the vortex interference patterns.
Sim, L; Manthey, K; Esdaile, P; Benson, M
2004-09-01
A study to compare the performance of the following display monitors for application as PACS CR diagnostic workstations is described. 1. Diagnostic quality, 3 megapixel, 21 inch monochrome LCD monitors. 2. Commercial grade, 2 megapixel, 20 inch colour LCD monitors. Two sets of fifty radiological studies each were presented separately to five radiologists on two occasions, using different displays on each occasion. The two sets of radiological studies were CR of the chest, querying the presence of pneumothorax, and CR of the wrist, querying the presence of a scaphoid fracture. Receiver Operating Characteristic (ROC) curves were constructed for diagnostic performance for each presentation. Areas under the ROC curves (AUC) for diagnosis using different monitors were compared for each image set and the following results obtained: Set 1: Monochrome AUC = 0.873 +/- 0.026; Colour AUC = 0.831 +/- 0.032; Set 2: Monochrome AUC = 0.945 +/- 0.014; Colour AUC = 0.931 +/- 0.019; Differences in AUC were attributed to the different monitors. While not significant at a 95% confidence level, the results have supported a cautious approach to consideration of the use of commercial grade LCD colour monitors for diagnostic application.
Full-color OLED on silicon microdisplay
NASA Astrophysics Data System (ADS)
Ghosh, Amalkumar P.
2002-02-01
eMagin has developed numerous enhancements to organic light emitting diode (OLED) technology, including a unique, up- emitting structure for OLED-on-silicon microdisplay devices. Recently, eMagin has fabricated full color SVGA+ resolution OLED microdisplays on silicon, with over 1.5 million color elements. The display is based on white light emission from OLED followed by LCD-type red, green and blue color filters. The color filters are patterned directly on OLED devices following suitable thin film encapsulation and the drive circuits are built directly on single crystal silicon. The resultant color OLED technology, with hits high efficiency, high brightness, and low power consumption, is ideally suited for near to the eye applications such as wearable PCS, wireless Internet applications and mobile phone, portable DVD viewers, digital cameras and other emerging applications.
NASA Astrophysics Data System (ADS)
Tao, Jiayou; Liu, Nishuang; Ma, Wenzhen; Ding, Longwei; Li, Luying; Su, Jun; Gao, Yihua
2013-07-01
A solid-state flexible supercapacitor (SC) based on organic-inorganic composite structure was fabricated through an ``in situ growth for conductive wrapping'' and an electrode material of polypyrrole (PPy)-MnO2 nanoflakes-carbon fiber (CF) hybrid structure was obtained. The conductive organic material of PPy greatly improved the electrochemical performance of the device. With a high specific capacitance of 69.3 F cm-3 at a discharge current density of 0.1 A cm-3 and an energy density of 6.16 × 10-3 Wh cm-3 at a power density of 0.04 W cm-3, the device can drive a commercial liquid crystal display (LCD) after being charged. The organic-inorganic composite active materials have enormous potential in energy management and the ``in situ growth for conductive wrapping'' method might be generalized to open up new strategies for designing next-generation energy storage devices.
[Development of opened instrument for generating and measuring physiological signal].
Chen, Longcong; Hu, Guohu; Gao, Bin
2004-12-01
An opened instrument with liquid crystal display (LCD) for generating and measuring physiological signal is introduced in this paper. Based on a single-chip microcomputer. the instrument uses the technique of LCD screen to display signal wave and information, and it realizes man-machine interaction by keyboard. This instrument can produce not only defined signal in common use by utilizing important saved data and relevant arithmetic, but also user-defined signal. Therefore, it is open to produce signal. In addition, this instrument has strong extension because of its modularized design as computer, which has much function such as displaying, measuring and saving physiological signal, and many features such as low power consumption, small volume, low cost and portability. Hence this instrument is convenient for experiment teaching, clinic examining, maintaining of medical instrument.
48 CFR 52.223-14 - Acquisition of EPEAT®-Registered Televisions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... crystal display (LCD), plasma display, or other display technology. Televisions with computer capability... the time of submission of proposals and at the time of award, were EPEAT® bronze-registered or higher... use at a Federally controlled facility, only televisions that, at the time of submission of proposals...
Impact of defective pixels in AMLCDs on the perception of medical images
NASA Astrophysics Data System (ADS)
Kimpe, Tom; Sneyders, Yuri
2006-03-01
With LCD displays, each pixel has its own individual transistor that controls the transmittance of that pixel. Occasionally, these individual transistors will short or alternatively malfunction, resulting in a defective pixel that always shows the same brightness. With ever increasing resolution of displays the number of defect pixels per display increases accordingly. State of the art processes are capable of producing displays with no more than one faulty transistor out of 3 million. A five Mega Pixel medical LCD panel contains 15 million individual sub pixels (3 sub pixels per pixel), each having an individual transistor. This means that a five Mega Pixel display on average will have 5 failing pixels. This paper investigates the visibility of defective pixels and analyzes the possible impact of defective pixels on the perception of medical images. JND simulations were done to study the effect of defective pixels on medical images. Our results indicate that defective LCD pixels can mask subtle features in medical images in an unexpectedly broad area around the defect and therefore may reduce the quality of diagnosis for specific high-demanding areas such as mammography. As a second contribution an innovative solution is proposed. A specialized image processing algorithm can make defective pixels completely invisible and moreover can also recover the information of the defect so that the radiologist perceives the medical image correctly. This correction algorithm has been validated with both JND simulations and psycho visual tests.
NASA Technical Reports Server (NTRS)
2002-01-01
Dimension Technologies Inc., developed a line of 2-D/3-D Liquid Crystal Display (LCD) screens, including a 15-inch model priced at consumer levels. DTI's family of flat panel LCD displays, called the Virtual Window(TM), provide real-time 3-D images without the use of glasses, head trackers, helmets, or other viewing aids. Most of the company initial 3-D display research was funded through NASA's Small Business Innovation Research (SBIR) program. The images on DTI's displays appear to leap off the screen and hang in space. The display accepts input from computers or stereo video sources, and can be switched from 3-D to full-resolution 2-D viewing with the push of a button. The Virtual Window displays have applications in data visualization, medicine, architecture, business, real estate, entertainment, and other research, design, military, and consumer applications. Displays are currently used for computer games, protein analysis, and surgical imaging. The technology greatly benefits the medical field, as surgical simulators are helping to increase the skills of surgical residents. Virtual Window(TM) is a trademark of Dimension Technologies Inc.
Accommodative and convergence response to computer screen and printed text
NASA Astrophysics Data System (ADS)
Ferreira, Andreia; Lira, Madalena; Franco, Sandra
2011-05-01
The aim of this work was to find out if differences exist in accommodative and convergence response for different computer monitors' and a printed text. It was also tried to relate the horizontal heterophoria value and accommodative response with the symptoms associated with computer use. Two independents experiments were carried out in this study. The first experiment was measuring the accommodative response on 89 subjects using the Grand Seiko WAM-5500 (Grand Seiko Co., Ltd., Japan). The accommodative response was measured using three computer monitors: a 17-inch cathode ray tube (CRT), two liquid crystal displays LCDs, one 17-inch (LCD17) and one 15 inches (LCD15) and a printed text. The text displayed was always the same for all the subjects and tests. A second experiment aimed to measure the value of habitual horizontal heterophoria on 80 subjects using the Von Graefe technique. The measurements were obtained using the same target presented on two different computer monitors, one 19-inch cathode ray tube (CRT) and other 19 inches liquid crystal displays (LCD) and printed on paper. A small survey about the incidence and prevalence of symptoms was performed similarly in both experiments. In the first experiment, the accommodation response was higher in the CRT and LCD's than for paper. There were not found significantly different response for both LCD monitors'. The second experiment showed that, the heterophoria values were similar for all the stimuli. On average, participants presented a small exophoria. In both experiments, asthenopia was the symptom that presented higher incidence. There are different accommodative responses when reading on paper or on computer monitors. This difference is more significant for CRT monitors. On the other hand, there was no difference in the values of convergence for the computer monitors' and paper. The symptoms associated with the use of computers are not related with the increase in accommodation and with the horizontal heterophoria values.
Optical characterization of display screens by speckle-contrast measurements
NASA Astrophysics Data System (ADS)
Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel
2012-10-01
In recent years, the flat-panel display (FPD) technology has undergone great development. Currently, FPDs are present in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surface which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider images shown in these types of displays to have more vivid colours compared with matte-screen displays. However, external light sources may cause unpleasant reflections on the glossy screens. These reflections can be reduced by a matte treatment in the front surface of FPDs. In this work, we present a method to characterize the front surface of FPDs using laser speckle patterns. We characterized three FPDs: a Samsung XL2370 LCD monitor of 23" with matte screen, a Toshiba Satellite A100 laptop of 15.4" with glossy screen, and a Papyre electronic book reader. The results show great differences in speckle contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs which have different types of front surfaces.
Development and evaluation of amusement machine using autostereoscopic 3D display
NASA Astrophysics Data System (ADS)
Kawai, Takashi; Shibata, Takashi; Shimizu, Yoichi; Kawata, Mitsuhiro; Suto, Masahiro
2004-05-01
Pachinko is a pinball-like game peculiar to Japan, and is one of the most common pastimes around the country. Recently, with the videogame market contracting, various multimedia technologies have been introduced into Pachinko machines. The authors have developed a Pachinko machine incorporating an autostereoscopic 3D display, and evaluated its effect on the visual function. As of April 2003, the new Pachinko machine has been on sale in Japan. The stereoscopic 3D image is displayed using an LCD. Backlighting for the right and left images is separate, and passes through a polarizing filter before reaching the LCD, which is sandwiched with a micro polarizer. The content selected for display was ukiyoe pictures (Japanese traditional woodblocks). The authors intended to reduce visual fatigue by presenting 3D images with depth "behind" the display and switching between 3D and 2D images. For evaluation of the Pachinko machine, a 2D version with identical content was also prepared, and the effects were examined and compared by testing psycho-physiological responses.
Peterka, Tom; Kooima, Robert L; Sandin, Daniel J; Johnson, Andrew; Leigh, Jason; DeFanti, Thomas A
2008-01-01
A solid-state dynamic parallax barrier autostereoscopic display mitigates some of the restrictions present in static barrier systems, such as fixed view-distance range, slow response to head movements, and fixed stereo operating mode. By dynamically varying barrier parameters in real time, viewers may move closer to the display and move faster laterally than with a static barrier system, and the display can switch between 3D and 2D modes by disabling the barrier on a per-pixel basis. Moreover, Dynallax can output four independent eye channels when two viewers are present, and both head-tracked viewers receive an independent pair of left-eye and right-eye perspective views based on their position in 3D space. The display device is constructed by using a dual-stacked LCD monitor where a dynamic barrier is rendered on the front display and a modulated virtual environment composed of two or four channels is rendered on the rear display. Dynallax was recently demonstrated in a small-scale head-tracked prototype system. This paper summarizes the concepts presented earlier, extends the discussion of various topics, and presents recent improvements to the system.
Virtually-augmented interfaces for tactical aircraft.
Haas, M W
1995-05-01
The term Fusion Interface is defined as a class of interface which integrally incorporates both virtual and non-virtual concepts and devices across the visual, auditory and haptic sensory modalities. A fusion interface is a multi-sensory virtually-augmented synthetic environment. A new facility has been developed within the Human Engineering Division of the Armstrong Laboratory dedicated to exploratory development of fusion-interface concepts. One of the virtual concepts to be investigated in the Fusion Interfaces for Tactical Environments facility (FITE) is the application of EEG and other physiological measures for virtual control of functions within the flight environment. FITE is a specialized flight simulator which allows efficient concept development through the use of rapid prototyping followed by direct experience of new fusion concepts. The FITE facility also supports evaluation of fusion concepts by operational fighter pilots in a high fidelity simulated air combat environment. The facility was utilized by a multi-disciplinary team composed of operational pilots, human-factors engineers, electronics engineers, computer scientists, and experimental psychologists to prototype and evaluate the first multi-sensory, virtually-augmented cockpit. The cockpit employed LCD-based head-down displays, a helmet-mounted display, three-dimensionally localized audio displays, and a haptic display. This paper will endeavor to describe the FITE facility architecture, some of the characteristics of the FITE virtual display and control devices, and the potential application of EEG and other physiological measures within the FITE facility.
NASA Astrophysics Data System (ADS)
Sugriwan, I.; Soesanto, O.
2017-05-01
The research was focused on development of data acquisition system to monitor the content of methane, relative humidity and temperature on peatlands in South Kalimantan, Indonesia. Methane is one of greenhouse gases that emitted from peatlands; while humidity and temperature are important parameters of microclimate on peatlands. The content of methane, humidity and temperature are three parameters were monitored digitally, real time, continuously and automatically record by data acquisition systems that interfaced to the personal computer. The hardware of data acquisition system consists of power supply unit, TGS2611 methane gas sensor, SHT11 humidity and temperature sensors, voltage follower, ATMega8535 microcontroller, 16 × 2 LCD character and personal computer. ATMega8535 module is a device to manage all part in measuring instrument. The software which is responsible to take sensor data, calculate characteristic equation and send data to 16 × 2 LCD character are Basic Compiler. To interface between measuring instrument and personal computer is maintained by Delphi 7. The result of data acquisition showed on 16 × 2 LCD characters, PC monitor and database with developed by XAMPP. Methane, humidity, and temperature which release from peatlands are trapped by Closed-Chamber Measurement with dimension 60 × 50 × 40 cm3. TGS2611 methane gas sensor and SHT11 humidity and temperature sensor are calibrated to determine transfer function used to data communication between sensors and microcontroller and integrated into ATMega8535 Microcontroller. Calculation of RS and RL of TGS2611 methane gas sensor refer to data sheet and obtained respectively 1360 ohm and 905 ohm. The characteristic equation of TGS2611 satisfies equation VRL = 0.561 ln n - 2.2641 volt, with n is a various concentrations and VRL in volt. The microcontroller maintained the voltage signal than interfaced it to liquid crystal displays and personal computer (laptop) to display result of the measurement. The result of data acquisition saved on excels and database format.
A ECG Signal Gathering and Displaying System Based on AVR
NASA Astrophysics Data System (ADS)
Ning, Li; Ruilan, Zhang; Jian, Liu; Xiaochen, Wang; Shuying, Chen; Zhuolin, Lang
2017-12-01
This article introduces a kind of system which is based on the AVR to acquire the data of ECG. Such system using the A/D function of ATmega8 chip and the lattice graph LCD to design ECG heart acquisition satisfies the demands above. This design gives a composition of hardware and programming of software about the system in detail which has mainly realized the real-time gathering, the amplifier, the filter, the A/D transformation and the LCD display. Since the AVR includes A/D transformation function and support embedded C language programming, it reduces the peripheral circuit, further more it also decreases the time to design and debug this system.
64.1: Display Technologies for Therapeutic Applications of Virtual Reality
Hoffman, Hunter G.; Schowengerdt, Brian T.; Lee, Cameron M.; Magula, Jeff; Seibel, Eric J.
2015-01-01
A paradigm shift in image source technology for VR helmets is needed. Using scanning fiber displays to replace LCD displays creates lightweight, safe, low cost, wide field of view, portable VR goggles ideal for reducing pain during severe burn wound care in hospitals and possibly in austere combat-transport environments. PMID:26146424
Investigation of ITO free transparent conducting polymer based electrode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Vikas; Sapna,; Sachdev, Kanupriya
2016-05-23
The last few decades have seen a significant improvement in organic semiconductor technology related to solar cell, light emitting diode and display panels. The material and structure of the transparent electrode is one of the major concerns for superior performance of devices such as OPV, OLED, touch screen and LCD display. Commonly used ITO is now restricted due to scarcity of indium, its poor mechanical properties and rigidity, and mismatch of energy levels with the active layer. Nowadays DMD (dielectric-metal-dielectric) structure is one of the prominent candidates as alternatives to ITO based electrode. We have used solution based spin coatedmore » polymer layer as the dielectric layer with silver thin film embedded in between to make a polymer-metal-polymer (PMP) structure for TCE applications. The PMP structure shows low resistivity (2.3 x 10{sup −4}Ω-cm), high carrier concentration (2.9 x 10{sup 21} cm{sup −3}) and moderate transparency. The multilayer PMP structure is characterized with XRD, AFM and Hall measurement to prove its suitability for opto-electronic device applications.« less
Exercise your physics when flying
NASA Astrophysics Data System (ADS)
Baffa, Oswaldo
1999-10-01
Recently, while flying, I found it difficult to sleep and started to pay attention to the television screens in the airplane. There were two types of TV to watch—a large cathode raye tube (CRT)monitor and smaller liquid crystal display (LCD) for passengers sitting near the bulkhead. In one of my glances at the large monitors I noticed that the colors were changing. I looked at the LCD monitors and the colors were fine. What could be happening?
Raster graphic helmet-mounted display study
NASA Technical Reports Server (NTRS)
Beamon, William S.; Moran, Susanna I.
1990-01-01
A design of a helmet mounted display system is presented, including a design specification and development plan for the selected design approach. The requirements for the helmet mounted display system and a survey of applicable technologies are presented. Three helmet display concepts are then described which utilize lasers, liquid crystal display's (LCD's), and subminiature cathode ray tubes (CRT's), respectively. The laser approach is further developed in a design specification and a development plan.
NASA Astrophysics Data System (ADS)
Chung, Jae-Moon; Zhang, Xiaokun; Shang, Fei; Kim, Ji-Hoon; Wang, Xiao-Lin; Liu, Shuai; Yang, Baoguo; Xiang, Yong
2018-05-01
To overcome the technological and economic obstacles of amorphous indium-gallium-zinc-oxide (a-IGZO)-based display backplane for industrial production, a clean etch-stopper (CL-ES) process is developed to fabricate a-IGZO-based thin film transistor (TFT) with improved uniformity and reproducibility on 8.5th generation glass substrates (2200 mm × 2500 mm). Compared with a-IGZO-based TFT with back-channel-etched (BCE) structure, a newly formed ES nano-layer ( 100 nm) and a simultaneous etching of a-IGZO nano-layer (30 nm) and source-drain electrode layer are firstly introduced to a-IGZO-based TFT device with CL-ES structure to improve the uniformity and stability of device for large-area display. The saturation electron mobility of 8.05 cm2/V s and the V th uniformity of 0.72 V are realized on the a-IGZO-based TFT device with CL-ES structure. In the negative bias temperature illumination stress and positive bias thermal stress reliability testing under a ± 30 V bias for 3600 s, the measured V th shift of CL-ES-structured device significantly decreased to - 0.51 and + 1.94 V, which are much lower than that of BCE-structured device (- 3.88 V, + 5.58 V). The electrical performance of the a-IGZO-based TFT device with CL-ES structure implies that the economic transfer from a silicon-based TFT process to the metal oxide semiconductor-based process for LCD fabrication is highly feasible.
Active learning in optics and photonics: Liquid Crystal Display in the do-it-yourself
NASA Astrophysics Data System (ADS)
Vauderwange, Oliver; Haiss, Ulrich; Wozniak, Peter; Israel, Kai; Curticapean, Dan
2015-10-01
Monitors are in the center of media productions and hold an important function as the main visual interface. Tablets and smartphones are becoming more and more important work tools in the media industry. As an extension to our lecture contents an intensive discussion of different display technologies and its applications is taking place now. The established LCD (Liquid Crystal Display) technology and the promising OLED (Organic Light Emitting Diode) technology are in the focus. The classic LCD is currently the most important display technology. The paper will present how the students should develop sense for display technologies besides the theoretical scientific basics. The workshop focuses increasingly on the technical aspects of the display technology and has the goal of deepening the students understanding of the functionality by building simple Liquid Crystal Displays by themselves. The authors will present their experience in the field of display technologies. A mixture of theoretical and practical lectures has the goal of a deeper understanding in the field of digital color representation and display technologies. The design and development of a suitable learning environment with the required infrastructure is crucial. The main focus of this paper is on the hands-on optics workshop "Liquid Crystal Display in the do-it-yourself".
NASA Astrophysics Data System (ADS)
Liu, Wei-Ting; Huang, Wen-Yao
2012-10-01
This study used the novel fluorescence based deep-blue-emitting molecule BPVPDA in an organic fluorescent color thin film to exhibit deep blue color with CIE coordinates of (0.13, 0.16). The developed original organic RGB color thin film technology enables the optimization of the distinctive features of an organic light emitting diode (OLED) and thin-film-transistor (TFT) LCD display. The color filter structure maintains the same high resolution to obtain a higher level of brightness in comparison with conventional organic RGB color thin film. The image-processing engine is designed to achieve a sharp text image for a TFT LCD with organic color thin films. The organic color thin films structure uses an organic dye dopant in a limpid photoresist. With this technology, the following characteristics can be obtained: 1. high color reproduction of gamut ratio, and 2. improved luminous efficiency with organic color fluorescent thin film. This performance is among the best results ever reported for a color-filter used on TFT-LCD or OLED.
NASA Astrophysics Data System (ADS)
Liu, Wei-ting; Huang, Wen-Yao
2012-06-01
This study used novel fluorescence based deep-blue-emitting molecules, namely BPVPDA, an organic fluorescence color thin film using BPVPDA exhibit deep blue fluorine with CIE coordinates of (0.13,0.16). The developed original Organic RGB color thin film technology enables the optimization of the distinctive features of an organic light emitting diode (OLED) and (TFT) LCD display. The color filter structure maintains the same high resolution to obtain a higher level of brightness, in comparison with conventional organic RGB color thin film. The image-processing engine is designed to achieve a sharp text image for a thin-film-transistor (TFT) LCD with organic color thin films. The organic color thin films structure uses organic dye dopent in limpid photo resist. With this technology , the following characteristics can be obtained: (1) high color reproduction of gamut ratio, and (2) improved luminous efficiency with organic color fluorescence thin film. This performance is among the best results ever reported for a color-filter used on TFT-LCD and OLED.
Holographic display system for restoration of sight to the blind
Goetz, G A; Mandel, Y; Manivanh, R; Palanker, D V; Čižmár, T
2013-01-01
Objective We present a holographic near-the-eye display system enabling optical approaches for sight restoration to the blind, such as photovoltaic retinal prosthesis, optogenetic and other photoactivation techniques. We compare it with conventional LCD or DLP-based displays in terms of image quality, field of view, optical efficiency and safety. Approach We detail the optical configuration of the holographic display system and its characterization using a phase-only spatial light modulator. Main results We describe approaches to controlling the zero diffraction order and speckle related issues in holographic display systems and assess the image quality of such systems. We show that holographic techniques offer significant advantages in terms of peak irradiance and power efficiency, and enable designs that are inherently safer than LCD or DLP-based systems. We demonstrate the performance of our holographic display system in the assessment of cortical response to alternating gratings projected onto the retinas of rats. Significance We address the issues associated with the design of high brightness, near-the-eye display systems and propose solutions to the efficiency and safety challenges with an optical design which could be miniaturized and mounted onto goggles. PMID:24045579
Dezawa, Akira; Sairyo, Koichi
2014-05-01
Organic electroluminescence displays (OELD) use organic materials that self-emit light with the passage of an electric current. OELD provide high contrast, excellent color reproducibility at low brightness, excellent video images, and less restricted viewing angles. OELD are thus promising for medical use. This study compared the utility of an OELD with conventional liquid crystal displays (LCD) for imaging in orthopedic endoscopic surgery. One OELD and two conventional LCD that were indistinguishable in external appearance were used in this study. Images from 18 patients were displayed simultaneously on three monitors and evaluated by six orthopedic surgeons with extensive surgical experience. Images were shown for 2 min, repeated twice, and viewed from the front and side (diagonally). Surgeon rated both clinical utility (12 parameters) and image quality (11 parameters) for each image on a 5-point scale: 1, very good; 2, good; 3, average; 4, poor; and 5, very poor. For clinical utility in 16 percutaneous endoscopic discectomy cases, mean scores for all 12 parameters were significantly better on the OELD than on the LCD, including organ distinguishability (2.1 vs 3.2, respectively), lesion identification (2.2 vs 3.1), and overall viewing impression (2.1 vs 3.1). For image quality, all 11 parameters were better on the OELD than on LCD. Significant differences were identified in six parameters, including contrast (1.8 vs 2.9), color reproducibility in dark areas (1.8 vs 2.9), and viewing angle (2.2 vs 2.9). The high contrast and excellent color reproducibility of the OELD reduced the constraints of imaging under endoscopy, in which securing a field of view may be difficult. Distinguishability of organs was good, including ligaments, dura mater, nerves, and adipose tissue, contributing to good stereoscopic images of the surgical field. These findings suggest the utility of OELD for excellent display of surgical images and for enabling safe and highly accurate endoscopic surgery. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
NASA Astrophysics Data System (ADS)
Chen, Chun-Jen; Wu, Wen-Hong; Huang, Kuo-Cheng
2009-08-01
A multi-function lens test instrument is report in this paper. This system can evaluate the image resolution, image quality, depth of field, image distortion and light intensity distribution of the tested lens by changing the tested patterns. This system consists of a tested lens, a CCD camera, a linear motorized stage, a system fixture, an observer LCD monitor, and a notebook for pattern providing. The LCD monitor displays a serious of specified tested patterns sent by the notebook. Then each displayed pattern goes through the tested lens and images in the CCD camera sensor. Consequently, the system can evaluate the performance of the tested lens by analyzing the image of CCD camera with special designed software. The major advantage of this system is that it can complete whole test quickly without interruption due to part replacement, because the tested patterns are statically displayed on monitor and controlled by the notebook.
Stephens, Michael; Weber, Erica; Barrett, Steven F
2006-01-01
An assistive technology (AT) device was originally created for a young child who has difficulty communicating. The child is not able to talk and is not old enough to read yet. This rules out conventional communication devices that this child could use to communicate. A device was requested by the child's educator that would talk for the child. Originally it needed to be wristwatch size and able to visually cue the child so that the child would know what was going to be said. The project's first prototype was built by a senior design student. Although the basic features of the prototype functioned properly, it was not practical for day to day use. Originally a rebuild was requested by the educator but after further investigation it was decided that a new design was needed so that it could better cue the child. A new device was built using a high resolution graphic liquid crystal display (LCD), a voice recording chip and a microcontroller. The wristwatch size requirement was changed to meet available technology and the device was packaged to be used on a lanyard.
Further advances in autostereoscopic technology at Dimension Technologies Inc.
NASA Astrophysics Data System (ADS)
Eichenlaub, Jesse B.
1992-06-01
Dimension Technologies is currently one of three companies offering autostereoscopic displays for sale and one of several which are actively pursuing advances to the technology. We have devised a new autostereoscopic imaging technique which possesses several advantages over previously explored methods. We are currently manufacturing autostereoscopic displays based on this technology, as well as vigorously pursuing research and development toward more advanced displays. During the past year, DTI has made major strides in advancing its LCD based autostereoscopic display technology. DTI has developed a color product -- a stand alone 640 X 480 flat panel LCD based 3-D display capable of accepting input from IBM PC and Apple MAC computers or TV cameras, and capable of changing from 3-D mode to 2-D mode with the flip of a switch. DTI is working on development of a prototype second generation color product that will provide autostereoscopic 3-D while allowing each eye to see the full resolution of the liquid crystal display. And development is also underway on a proof-of-concept display which produces hologram-like look-around images visible from a wide viewing angle, again while allowing the observer to see the full resolution of the display from all locations. Development of a high resolution prototype display of this type has begun.
Chang, Yia-Chung; Tang, Li-Chuan; Yin, Chun-Yi
2013-01-01
Both an analytical formula and an efficient numerical method for simulation of the accumulated intensity profile of light that is refracted through a lenticular lens array placed on top of a liquid-crystal display (LCD) are presented. The influence due to light refracted through adjacent lens is examined in the two-view and four-view systems. Our simulation results are in good agreement with those obtained by a piece of commercial software, ASAP, but our method is much more efficient. This proposed method allows one to adjust the design parameters and carry out simulation for the performance of a subpixel-matched auto-stereoscopic LCD more efficiently and easily.
Oh, Seung-Won; Park, Jun-Hee; Lee, Ji-Hoon; Yoon, Tae-Hoon
2015-09-07
Recently, low-frequency driving of liquid crystal display (LCD) panels to minimize power consumption has drawn much attention. In the case in which an LCD panel is driven by a fringe-field at a low frequency, the image flickering phenomenon occurs when the sign of the applied electric field is reversed. We investigated image flickering induced by the flexoelectric effect in a fringe-field switching (FFS) liquid crystal cell in terms of the transmittance difference between frames and the ripple phenomenon. Experimental results show that image flicker due to transmittance difference can be eliminated completely and that the ripple phenomena can be reduced significantly by applying a bipolar voltage wave to the FFS cell.
NASA Astrophysics Data System (ADS)
de Coss Martinez, Romeo; Gonzalez Murguia, Jose Luis
2011-03-01
In this work we study the response of a Twisted Nematic Liquid Crystal Display (TN-LCD) by varying both the concentration and the polymer used for the microgroove. We compare the performance of two polymers: polyvinyl alcohol and soy lecithin. In particular, the light transmission for the ON/OFF states is evaluated. The polyvinyl alcohol is a polymer widely used in LCDs while lecithin soy is a natural polymer.
[Development of automatic urine monitoring system].
Wei, Liang; Li, Yongqin; Chen, Bihua
2014-03-01
An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.
Fast-response LCDs for virtual reality applications
NASA Astrophysics Data System (ADS)
Chen, Haiwei; Peng, Fenglin; Gou, Fangwang; Wand, Michael; Wu, Shin-Tson
2017-02-01
We demonstrate a fast-response liquid crystal display (LCD) with an ultra-low-viscosity nematic LC mixture. The measured average motion picture response time is only 6.88 ms, which is comparable to 6.66 ms for an OLED at a 120 Hz frame rate. If we slightly increase the TFT frame rate and/or reduce the backlight duty ratio, image blurs can be further suppressed to unnoticeable level. Potential applications of such an image-blur-free LCD for virtual reality, gaming monitors, and TVs are foreseeable.
A study of optical design of backlight module with external illuminance
NASA Astrophysics Data System (ADS)
Yen, Chih-Ta; Fang, Yi-Chin
2011-10-01
This research proposes the concept of Light Guide Film (LGF) at the back side of Back Light Unit (BLU). This new design may induce the exterior light, and then improve the power-saving of existent BLU. Two design models are reseated: One is design for 14 inch LCD monitor of notebook computer, which might improve 21% compared to traditional one. Another is designed for 3.5 inch LCD for mobile phone display, which might improve 15% compared to traditional one.
A portable detection instrument based on DSP for beef marbling
NASA Astrophysics Data System (ADS)
Zhou, Tong; Peng, Yankun
2014-05-01
Beef marbling is one of the most important indices to assess beef quality. Beef marbling is graded by the measurement of the fat distribution density in the rib-eye region. However quality grades of beef in most of the beef slaughtering houses and businesses depend on trainees using their visual senses or comparing the beef slice to the Chinese standard sample cards. Manual grading demands not only great labor but it also lacks objectivity and accuracy. Aiming at the necessity of beef slaughtering houses and businesses, a beef marbling detection instrument was designed. The instrument employs Charge-coupled Device (CCD) imaging techniques, digital image processing, Digital Signal Processor (DSP) control and processing techniques and Liquid Crystal Display (LCD) screen display techniques. The TMS320DM642 digital signal processor of Texas Instruments (TI) is the core that combines high-speed data processing capabilities and real-time processing features. All processes such as image acquisition, data transmission, image processing algorithms and display were implemented on this instrument for a quick, efficient, and non-invasive detection of beef marbling. Structure of the system, working principle, hardware and software are introduced in detail. The device is compact and easy to transport. The instrument can determine the grade of beef marbling reliably and correctly.
Re-engineering the stereoscope for the 21st Century
NASA Astrophysics Data System (ADS)
Kollin, Joel S.; Hollander, Ari J.
2007-02-01
While discussing the current state of stereo head-mounted and 3D projection displays, the authors came to the realization that flat-panel LCD displays offer higher resolution than projection for stereo display at a low (and continually dropping) cost. More specifically, where head-mounted displays of moderate resolution and field-of-view cost tens of thousands of dollars, we can achieve an angular resolution approaching that of the human eye with a field-of-view (FOV) greater than 90° for less than $1500. For many immersive applications head tracking is unnecessary and sometimes even undesirable, and a low cost/high quality wide FOV display may significantly increase the application space for 3D display. After outlining the problem and potential of this solution we describe the initial construction of a simple Wheatstone stereoscope using 24" LCD displays and then show engineering improvements that increase the FOV and usability of the system. The applicability of a high-immersion, high-resolution display for art, entertainment, and simulation is presented along with a content production system that utilizes the capabilities of the system. We then discuss the potential use of the system for VR pain control therapy, treatment of post-traumatic stress disorders and other serious games applications.
Tao, Jiayou; Liu, Nishuang; Ma, Wenzhen; Ding, Longwei; Li, Luying; Su, Jun; Gao, Yihua
2013-01-01
A solid-state flexible supercapacitor (SC) based on organic-inorganic composite structure was fabricated through an “in situ growth for conductive wrapping” and an electrode material of polypyrrole (PPy)-MnO2 nanoflakes-carbon fiber (CF) hybrid structure was obtained. The conductive organic material of PPy greatly improved the electrochemical performance of the device. With a high specific capacitance of 69.3 F cm−3 at a discharge current density of 0.1 A cm−3 and an energy density of 6.16 × 10−3 Wh cm−3 at a power density of 0.04 W cm−3, the device can drive a commercial liquid crystal display (LCD) after being charged. The organic-inorganic composite active materials have enormous potential in energy management and the “in situ growth for conductive wrapping” method might be generalized to open up new strategies for designing next-generation energy storage devices. PMID:23884478
Command and Data Handling Branch Internship
NASA Technical Reports Server (NTRS)
Billings, Rachel Mae
2016-01-01
Modular Integrated Stackable Layers (MISL) is a computer system designed for simple, fast, and cost effective flexible reconfiguration in space environments such as the ISS and Orion projects for various uses. Existing applications include wireless and wired communications, data acquisition and instrumentation, and camera systems, and potential applications include bus protocol converters and subsystem control. MISL is based on Texas Instruments (TI)' MSP430 16-bit ultra-low-power microcontroller device. The purpose of my project was to integrate the MISL system with a liquid crystal display (LCD) touchscreen. The LCD, manufactured by Crystalfontz and part number CFAF320240F-035T-TS, is a 320 by 240 RGB resistive color screen including an optional carrier board. The vast majority of the project was done with Altium Designer, a tool for printed circuit board (PCB) schematic capture, 3D design, and FPGA (Field Programmable Gate Array) development. The new PCB was to allow the LCD to directly stack to the rest of MISL. Research was done with datasheets for the TI microcontroller and touchscreen display in order to meet desired hardware specifications. Documentation on prior MISL projects was also utilized. The initial step was to create a schematic for the LCD, power bus, and data bus connections between components. A layout was then designed with the required physical dimensions, routed traces and vias, power and ground planes, layer stacks, and other specified design rules such as plane clearance and hole size. Multiple consultation sessions were held with Hester Yim, the technical discipline lead for the Command and Data Handling Branch, and Christy Herring, the lead PCB layout designer in the Electronic Design and Manufacturing Branch in order to ensure proper configuration. At the moment, the PCB is awaiting revision by the latter-mentioned branch. Afterwards, the board will begin to undergo the manufacturing and testing process. Throughout the internship at Johnson Space Center, I gained several technical and professional skills. I gained proficiency in Altium Designer and experience using subversion clients, as well as knowledge in PSpice with OrCAD and battery design for spaceflight from on-site. I also gained networking, organization, and communication skills throughout meetings with coworkers and other interns. This internship at Johnson Space Center has impacted my future aspirations by further inspiring me to follow a career path into space rated engineering technology and human spaceflight applications. After graduation, I plan to attend graduate Modular Integrated Stackable Layers (MISL) is a computer system designed for simple, fast, and cost effective flexible reconfiguration in space environments such as the ISS and Orion projects for various uses. Existing applications include wireless and wired communications, data acquisition and instrumentation, and camera systems, and potential applications include bus protocol converters and subsystem control. MISL is based on Texas Instruments’ MSP430 16 bit ultra-low power microcontroller device. The purpose of my project was to integrate the MISL system with a liquid crystal display touchscreen. The LCD, manufactured by Crystalfontz and part number CFAF320240F-035T-TS, is a 320x240 RGB resistive color screen including an optional carrier board.The vast majority of the project was done with Altium Designer, a tool for printed circuit board (PCB) schematic capture, 3D design, and FPGA development. The new PCB was to allow the LCD to directly stack to the rest of MISL. Research was done with datasheets for the TI microcontroller and touchscreen display in order to meet desired hardware specifications. Documentation on prior MISL projects was also utilized. The initial step was to create a schematic for the LCD, power bus, and data bus connections between components. A layout was then designed with the required physical dimensions, routed traces and vias, power and ground planes, layer stacks, and other specified design rules such as plane clearance and hole size. Multiple consultation sessions were held with Hester Yim, the technical discipline lead for the Command and Data Handling Branch, and Christy Herring, the lead PCB layout designer in the Electronic Design and Manufacturing Branch in order to ensure proper configuration. At themoment, the PCB is awaiting revision by the latter-mentioned branch. Afterwards, the board will begin to undergo the manufacturing and testing process.Throughout the internship at Johnson Space Center, I gained several technical and professional skills. I gained proficiency in Altium Designer and experience using subversion clients, as well as knowledge in PSpice with OrCAD and battery design for spaceflight from on-site. I also gained networking, organization, and communication skills throughout meetings with coworkers and other interns. This internship at Johnson Space Center has impacted my future aspirations by further inspiring me to follow a career path into space rated engineering technology and human spaceflight applications. After graduation, I plan to attend graduate school for a master's or doctorate degree in electrical or computer engineering.
Comparison of pattern VEP results acquired using CRT and TFT stimulators in the clinical practice.
Nagy, Balázs Vince; Gémesi, Szabolcs; Heller, Dávid; Magyar, András; Farkas, Agnes; Abrahám, György; Varsányi, Balázs
2011-06-01
There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1° and 15' check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays' electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (±3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 ± 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.
NASA Astrophysics Data System (ADS)
Held, Marcel Philipp; Ley, Peer-Phillip; Lachmayer, Roland
2018-02-01
High-resolution vehicle headlamps represent a future-oriented technology that increases traffic safety and driving comfort in the dark. A further development to current matrix beam headlamps are LED-based pixellight systems which enable additional lighting functions (e.g. the projection of navigation information on the road) to be activated for given driving scenarios. The image generation is based on spatial light modulators (SLM) such as digital micromirror devices (DMD), liquid crystal displays (LCD), liquid crystal on silicon (LCoS) devices or LED arrays. For DMD-, LCD- and LCoSbased headlamps, the optical system uses illumining optics to ensure a precise illumination of the corresponding SLM. LED arrays, however, have to use imaging optics to project the LED die onto an intermediate image plane and thus create the light distribution via an apposition of gapless juxtapositional LED die images. Nevertheless, the lambertian radiation characteristics complex the design of imaging optics regarding a highefficiency setup with maximum resolution and luminous flux. Simplifying the light source model and its emitting characteristics allows to determine a balanced setup between these parameters by using the Etendue and to ´ calculate the maximum possible efficacy and luminous flux for each technology in an early designing stage. Therefore, we present a calculation comparison of how simplifying the light source model can affect the Etendue ´ conservation and the setup design for two high-resolution technologies. The shown approach is evaluated and compared to simulation models to show the occurring deviation and its applicability.
Assessment of toxic metals in waste personal computers.
Kolias, Konstantinos; Hahladakis, John N; Gidarakos, Evangelos
2014-08-01
Considering the enormous production of waste personal computers nowadays, it is obvious that the study of their composition is necessary in order to regulate their management and prevent any environmental contamination caused by their inappropriate disposal. This study aimed at determining the toxic metals content of motherboards (printed circuit boards), monitor glass and monitor plastic housing of two Cathode Ray Tube (CRT) monitors, three Liquid Crystal Display (LCD) monitors, one LCD touch screen monitor and six motherboards, all of which were discarded. In addition, concentrations of chromium (Cr), cadmium (Cd), lead (Pb) and mercury (Hg) were compared with the respective limits set by the RoHS 2002/95/EC Directive, that was recently renewed by the 2012/19/EU recast, in order to verify manufacturers' compliance with the regulation. The research included disassembly, pulverization, digestion and chemical analyses of all the aforementioned devices. The toxic metals content of all samples was determined using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The results demonstrated that concentrations of Pb in motherboards and funnel glass of devices with release dates before 2006, that is when the RoHS Directive came into force, exceeded the permissible limit. In general, except from Pb, higher metal concentrations were detected in motherboards in comparison with plastic housing and glass samples. Finally, the results of this work were encouraging, since concentrations of metals referred in the RoHS Directive were found in lower levels than the legislative limits. Copyright © 2014 Elsevier Ltd. All rights reserved.
Upadhyayula, Venkata K K; Meyer, David E; Curran, Mary Ann; Gonzalez, Michael A
2014-01-21
Carbon nanotube (CNT) field emission displays (FEDs) are currently in the product development stage and are expected to be commercialized in the near future because they offer image quality and viewing angles comparable to a cathode ray tube (CRT) while using a thinner structure, similar to a liquid crystal display (LCD), and enable more efficient power consumption during use. To address concerns regarding the environmental performance of CNT-FEDs, a screening-level, cradle-to-grave life cycle assessment (LCA) was conducted based on a functional unit of 10,000 viewing hours, the viewing lifespan of a CNT-FED. Contribution analysis suggests the impacts for material acquisition and manufacturing are greater than the combined impacts for use and end-of-life. A scenario analysis of the CNT paste composition identifies the metal components used in the paste are key contributors to the impacts of the upstream stages due to the impacts associated with metal preparation. Further improvement of the manufacturing impacts is possible by considering the use of plant-based oils, such as rapeseed oil, as alternatives to organic solvents for dispersion of CNTs. Given the differences in viewing lifespan, the impacts of the CNT-FED were compared with a LCD and a CRT display to provide more insight on how to improve the CNT-FED to make it a viable product alternative. When compared with CRT technology, CNT-FEDs show better environmental performance, whereas a comparison with LCD technology indicates the environmental impacts are roughly the same. Based on the results, the enhanced viewing capabilities of CNT-FEDs will be a more viable display option if manufacturers can increase the product's expected viewing lifespan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokurei, S; Department of Radiology, Yamaguchi University Hospital, Ube, Yamaguchi; Morishita, J
2015-06-15
Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters weremore » computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.« less
On-axis programmable microscope using liquid crystal spatial light modulator
NASA Astrophysics Data System (ADS)
García-Martínez, Pascuala; Martínez, José Luís.; Moreno, Ignacio
2017-06-01
Spatial light modulators (SLM) are currently used in many applications in optical microscopy and imaging. One of the most promising methods is the use of liquid crystal displays (LCD) as programmable phase diffractive optical elements (DOE) placed in the Fourier plane giving access to the spatial frequencies which can be phased shifted individually, allowing to emulate a wealth of contrast enhancing methods for both amplitude and phase samples. We use phase and polarization modulation of LCD to implement an on-axis microscope optical system. The LCD used are Hamamatsu liquid crystal on silicon (LCOS) SLM free of flicker, thus showing a full profit of the SLM space bandwidth, as opposed to optical systems in the literature forced to work off-axis due to the strong zero-order component. Taking benefits of the phase modulation of the LCOS we have implemented different microscopic imaging operations, such as high-pass and low-pass filtering in parallel using programmable blazed gratings. Moreover, we are able to control polarization modulation to display two orthogonal linear state of polarization images than can be subtracted or added by changing the period of the blazed grating. In that sense, Differential Interference Contrast (DIC) microscopy can be easily done by generating two images exploiting the polarization splitting properties when a blazed grating is displayed in the SLM. Biological microscopy samples are also used.
Biological treatment of thin-film transistor liquid crystal display (TFT-LCD) wastewater.
Lei, C N; Whang, L M; Lin, H L
2008-01-01
The amount of pollutants produced during manufacturing processes of TFT-LCD (thin-film transistor liquid crystal display) substantially increases due to an increasing production of the opto-electronic industry in Taiwan. The total amount of wastewater from TFT-LCD manufacturing plants is expected to exceed 200,000 CMD in the near future. Typically, organic solvents used in TFT-LCD manufacturing processes account for more than 33% of the total TFT-LCD wastewater. The main components of these organic solvents are composed of the stripper (dimethyl sulphoxide (DMSO) and monoethanolamine (MEA)), developer (tetra-methyl ammonium hydroxide (TMAH)) and chelating agents. These compounds are recognized as non-or slow-biodegradable organic compounds and little information is available regarding their biological treatability. In this study, the performance of an A/O SBR (anoxic/oxic sequencing batch reactor) treating synthetic TFT-LCD wastewater was evaluated. The long-term experimental results indicated that the A/O SBR was able to achieve stable and satisfactory removal performance for DMSO, MEA and TMAH at influent concentrations of 430, 800, and 190 mg/L, respectively. The removal efficiencies for all three compounds examined were more than 99%. In addition, batch tests were conducted to study the degradation kinetics of DMSO, MEA, and TMAH under aerobic, anoxic, and anaerobic conditions, respectively. The organic substrate of batch tests conducted included 400 mg/L of DMSO, 250 mg/L of MEA, and 120 mg/L of TMAH. For DMSO, specific DMSO degradation rates under aerobic and anoxic conditions were both lower than 4 mg DMSO/g VSS-hr. Under anaerobic conditions, the specific DMSO degradation rate was estimated to be 14 mg DMSO/g VSS-hr, which was much higher than those obtained under aerobic and anoxic conditions. The optimum specific MEA and TMAH degradation rates were obtained under aerobic conditions with values of 26.5 mg MEA/g VSS-hr and 17.3 mg TMAH/g VSS-hr, respectively. Compared to aerobic conditions, anaerobic biodegradation of MEA and TMAH was much less significant with values of 5.6 mg MEA/g VSS-hr and 0 mg TMAH/g VSS-hr, respectively. In summary, biological treatment of TFT-LCD wastewater containing DMSO, MEA, and TMAH is feasible, but appropriate conditions for optimum biodegradation of DMSO, MEA, and TMAH are crucial and require carefully operational consideration. Copyright IWA Publishing 2008.
Chang, Ta-Yuan; Huang, Kuei-Hung; Liu, Chiu-Shong; Shie, Ruei-Hao; Chao, Keh-Ping; Hsu, Wen-Hsin; Bao, Bo-Ying
2010-06-15
Many volatile organic compounds (VOCs) are emitted during the manufacturing of thin film transistor liquid crystal displays (TFT-LCDs), exposure to some of which has been reported to be associated with kidney dysfunction, but whether such an effect exists in TFT-LCD industry workers is unknown. This cross-sectional study aimed to investigate the association between exposure to VOCs and kidney dysfunction among TFT-LCD workers. The results showed that ethanol (1811.0+/-1740.4 ppb), acetone (669.0+/-561.0 ppb), isopropyl alcohol (187.0+/-205.3 ppb) and propylene glycol monomethyl ether acetate (PGMEA) (102.9+/-102.0 ppb) were the four dominant VOCs present in the workplace. The 63 array workers studied had a risk of kidney dysfunction 3.21-fold and 3.84-fold that of 61 cell workers and 18 module workers, respectively. Workers cumulatively exposed to a total level of isopropyl alcohol, PGMEA and propylene glycol monomethyl ether> or =324 ppb-year had a significantly higher risk of kidney dysfunction (adjusted OR=3.41, 95% CI=1.14-10.17) compared with those exposed to <25 ppb-year after adjustment for potential confounding factors. These findings indicated that array workers might be the group at greatest risk of kidney dysfunction within the TFT-LCD industry, and cumulative exposure to specific VOCs might be associated with kidney dysfunction. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.
Liu, Cheng-Li
2009-05-01
Only a few studies in the literature have focused on the effects of age on virtual environment (VE) sickness susceptibility and even less research was carried out focusing on the elderly. In general, the elderly usually browse VEs on a thin film transistor liquid crystal display (TFT-LCD) at home or somewhere, not a head-mounted display (HMD). While the TFT-LCD is used to present VEs, this set-up does not physically enclose the user. Therefore, this study investigated the factors that contribute to cybersickness among the elderly when immersed into a VE on TFT-LCD, including exposure durations, navigation rotating speeds and angle of inclination. Participants were elderly, with an average age of 69.5 years. The results of the first experiment showed that the rate of simulator sickness questionnaire (SSQ) scores increases significantly with navigational rotating speed and duration of exposure. However, the experimental data also showed that the rate of SSQ scores does not increase with the increase in angle of inclination. In applying these findings, the neuro-fuzzy technology was used to develop a neuro-fuzzy cybersickness-warning system integrating fuzzy logic reasoning and neural network learning. The contributing factors were navigational rotating speed and duration of exposure. The results of the second experiment showed that the proposed system can efficiently determine the level of cybersickness based on the associated subjective sickness estimates and combat cybersickness due to long exposure to a VE.
Murawski, Nathen J; Asok, Arun
2017-01-10
The precise contribution of visual information to contextual fear learning and discrimination has remained elusive. To better understand this contribution, we coupled the context pre-exposure facilitation effect (CPFE) fear conditioning paradigm with presentations of distinct visual scenes displayed on 4 LCD screens surrounding a conditioning chamber. Adult male Long-Evans rats received non-reinforced context pre-exposure on Day 1, an immediate 1.5mA foot shock on Day 2, and a non-reinforced context test on Day 3. Rats were pre-exposed to either digital Context (dCtx) A, dCtx B, a distinct Ctx C, or no context on Day 1. Digital context A and B were identical except for the visual image displayed on the LCD screens. Immediate shock and retention testing occurred in dCtx A. Rats pre-exposed dCtx A showed the CPFE with significantly higher levels of freezing compared to controls. Rats pre-exposed to Context B failed to show the CPFE, with freezing that did not highly differ from controls. These results suggest that visual information contributes to contextual fear learning and that visual components of the context can be manipulated via LCD screens. Our approach offers a simple modification to contextual fear conditioning paradigms whereby the visual features of a context can be manipulated to better understand the factors that contribute to contextual fear discrimination and generalization. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Head-mounted display for use in functional endoscopic sinus surgery
NASA Astrophysics Data System (ADS)
Wong, Brian J.; Lee, Jon P.; Dugan, F. Markoe; MacArthur, Carol J.
1995-05-01
Since the introduction of functional endoscopic sinus surgery (FESS), the procedure has undergone rapid change with evolution keeping pace with technological advances. The advent of low cost charge coupled device 9CCD) cameras revolutionized the practice and instruction of FESS. Video-based FESS has allowed for documentation of the surgical procedure as well as interactive instruction during surgery. Presently, the technical requirements of video-based FESS include the addition of one or more television monitors positioned strategically in the operating room. Thought video monitors have greatly enhanced surgical endoscopy by re- involving nurses and assistants in the actual mechanics of surgery, video monitors require the operating surgeon to be focused on the screen instead of the patient. In this study, we describe the use of a new low-cost liquid crystal display (LCD) based device that functions as a monitor but is mounted on the head on a visor (PT-O1, O1 Products, Westlake Village, CA). This study illustrates the application of these HMD devices to FESS operations. The same surgeon performed the operation in each patient. In one nasal fossa, surgery was performed using conventional video FESS methods. The contralateral side was operated on while wearing the head mounted video display. The device had adequate resolution for the purposes of FESS. No adverse effects were noted intraoperatively. The results on the patients ipsalateral and contralateral sides were similar. The visor did eliminated significant torsion of the surgeon's neck during the operation, while at the same time permitted simultaneous viewing of both the patient and the intranasal surgical field.
Large-screen display industry: market and technology trends for direct view and projection displays
NASA Astrophysics Data System (ADS)
Castellano, Joseph A.; Mentley, David E.
1996-03-01
Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.
Low-cost compact ECG with graphic LCD and phonocardiogram system design.
Kara, Sadik; Kemaloğlu, Semra; Kirbaş, Samil
2006-06-01
Till today, many different ECG devices are made in developing countries. In this study, low cost, small size, portable LCD screen ECG device, and phonocardiograph were designed. With designed system, heart sounds that take synchronously with ECG signal are heard as sensitive. Improved system consist three units; Unit 1, ECG circuit, filter and amplifier structure. Unit 2, heart sound acquisition circuit. Unit 3, microcontroller, graphic LCD and ECG signal sending unit to computer. Our system can be used easily in different departments of the hospital, health institution and clinics, village clinic and also in houses because of its small size structure and other benefits. In this way, it is possible that to see ECG signal and hear heart sounds as synchronously and sensitively. In conclusion, heart sounds are heard on the part of both doctor and patient because sounds are given to environment with a tiny speaker. Thus, the patient knows and hears heart sounds him/herself and is acquainted by doctor about healthy condition.
LCD motion blur reduction: a signal processing approach.
Har-Noy, Shay; Nguyen, Truong Q
2008-02-01
Liquid crystal displays (LCDs) have shown great promise in the consumer market for their use as both computer and television displays. Despite their many advantages, the inherent sample-and-hold nature of LCD image formation results in a phenomenon known as motion blur. In this work, we develop a method for motion blur reduction using the Richardson-Lucy deconvolution algorithm in concert with motion vector information from the scene. We further refine our approach by introducing a perceptual significance metric that allows us to weight the amount of processing performed on different regions in the image. In addition, we analyze the role of motion vector errors in the quality of our resulting image. Perceptual tests indicate that our algorithm reduces the amount of perceivable motion blur in LCDs.
In-TFT-array-process micro defect inspection using nonlinear principal component analysis.
Liu, Yi-Hung; Wang, Chi-Kai; Ting, Yung; Lin, Wei-Zhi; Kang, Zhi-Hao; Chen, Ching-Shun; Hwang, Jih-Shang
2009-11-20
Defect inspection plays a critical role in thin film transistor liquid crystal display (TFT-LCD) manufacture, and has received much attention in the field of automatic optical inspection (AOI). Previously, most focus was put on the problems of macro-scale Mura-defect detection in cell process, but it has recently been found that the defects which substantially influence the yield rate of LCD panels are actually those in the TFT array process, which is the first process in TFT-LCD manufacturing. Defect inspection in TFT array process is therefore considered a difficult task. This paper presents a novel inspection scheme based on kernel principal component analysis (KPCA) algorithm, which is a nonlinear version of the well-known PCA algorithm. The inspection scheme can not only detect the defects from the images captured from the surface of LCD panels, but also recognize the types of the detected defects automatically. Results, based on real images provided by a LCD manufacturer in Taiwan, indicate that the KPCA-based defect inspection scheme is able to achieve a defect detection rate of over 99% and a high defect classification rate of over 96% when the imbalanced support vector machine (ISVM) with 2-norm soft margin is employed as the classifier. More importantly, the inspection time is less than 1 s per input image.
Market trends in the projection display industry
NASA Astrophysics Data System (ADS)
Dash, Sweta
2000-04-01
The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection television segment. But rear LCD (liquid crystal display) and rear reflective (DLP, or Digital Light ProcessingTM) televisions are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are still popular in the high-end home theater market. Front LCD technology and front DLP technology dominate the business market. Traditional light valve technology was the only solution for applications requiring high light outputs, but new three-chip DLP projectors meet the higher light output requirements at a lower price. In the last few years the strongest growth has been in the business market for multimedia presentation applications. This growth was due to the continued increase in display pixel formats, the continued reduction in projector weight, and the improved price/performance ratio. The projection display market will grow at a significant rate during the next five years, driven by the growth in ultraportable (< 10 pound) projectors and the shift in the consumer market to digital and HDTV products.
Temporal Properties of Liquid Crystal Displays: Implications for Vision Science Experiments
Elze, Tobias; Tanner, Thomas G.
2012-01-01
Liquid crystal displays (LCD) are currently replacing the previously dominant cathode ray tubes (CRT) in most vision science applications. While the properties of the CRT technology are widely known among vision scientists, the photometric and temporal properties of LCDs are unfamiliar to many practitioners. We provide the essential theory, present measurements to assess the temporal properties of different LCD panel types, and identify the main determinants of the photometric output. Our measurements demonstrate that the specifications of the manufacturers are insufficient for proper display selection and control for most purposes. Furthermore, we show how several novel display technologies developed to improve fast transitions or the appearance of moving objects may be accompanied by side–effects in some areas of vision research. Finally, we unveil a number of surprising technical deficiencies. The use of LCDs may cause problems in several areas in vision science. Aside from the well–known issue of motion blur, the main problems are the lack of reliable and precise onsets and offsets of displayed stimuli, several undesirable and uncontrolled components of the photometric output, and input lags which make LCDs problematic for real–time applications. As a result, LCDs require extensive individual measurements prior to applications in vision science. PMID:22984458
Liquid-crystal displays for medical imaging: a discussion of monochrome versus color
NASA Astrophysics Data System (ADS)
Wright, Steven L.; Samei, Ehsan
2004-05-01
A common view is that color displays cannot match the performance of monochrome displays, normally used for diagnostic x-ray imaging. This view is based largely on historical experience with cathode-ray tube (CRT) displays, and does not apply in the same way to liquid-crystal displays (LCDs). Recent advances in color LCD technology have considerably narrowed performance differences with monochrome LCDs for medical applications. The most significant performance advantage of monochrome LCDs is higher luminance, a concern for use under bright ambient conditions. LCD luminance is limited primarily by backlight design, yet to be optimized for color LCDs for medical applications. Monochrome LCDs have inherently higher contrast than color LCDs, but this is not a major advantage under most conditions. There is no practical difference in luminance precision between color and monochrome LCDs, with a slight theoretical advantage for color. Color LCDs can provide visualization and productivity enhancement for medical applications, using digital drive from standard commercial graphics cards. The desktop computer market for color LCDs far exceeds the medical monitor market, with an economy of scale. The performance-to-price ratio for color LCDs is much higher than monochrome, and warrants re-evaluation for medical applications.
Cunningham, Patrick D; Souza, João B; Fedin, Igor; She, Chunxing; Lee, Byeongdu; Talapin, Dmitri V
2016-06-28
Semiconductor nanorods can emit linear-polarized light at efficiencies over 80%. Polarization of light in these systems, confirmed through single-rod spectroscopy, can be explained on the basis of the anisotropy of the transition dipole moment and dielectric confinement effects. Here we report emission polarization in macroscopic semiconductor-polymer composite films containing CdSe/CdS nanorods and colloidal CdSe nanoplatelets. Anisotropic nanocrystals dispersed in polymer films of poly butyl-co-isobutyl methacrylate (PBiBMA) can be stretched mechanically in order to obtain unidirectionally aligned arrays. A high degree of alignment, corresponding to an orientation factor of 0.87, was achieved and large areas demonstrated polarized emission, with the contrast ratio I∥/I⊥ = 5.6, making these films viable candidates for use in liquid crystal display (LCD) devices. To some surprise, we observed significant optical anisotropy and emission polarization for 2D CdSe nanoplatelets with the electronic structure of quantum wells. The aligned nanorod arrays serve as optical funnels, absorbing unpolarized light and re-emitting light from deep-green to red with quantum efficiencies over 90% and high degree of linear polarization. Our results conclusively demonstrate the benefits of anisotropic nanostructures for LCD backlighting. The polymer films with aligned CdSe/CdS dot-in-rod and rod-in-rod nanostructures show more than 2-fold enhancement of brightness compared to the emitter layers with randomly oriented nanostructures. This effect can be explained as the combination of linearly polarized luminescence and directional emission from individual nanostructures.
Matsumoto, Celso Soiti; Shinoda, Kei; Matsumoto, Harue; Seki, Keisuke; Nagasaka, Eiichiro; Iwata, Takeshi; Mizota, Atsushi
2014-08-05
To compare a conventional cathode-ray tube (CRT) screen to organic light-emitting diode (OLED) and liquid crystal display (LCD) screens as visual stimulators to elicit multifocal electroretinograms (mfERGs), mfERGs were recorded from seven eyes of seven healthy volunteers (21 ± 2 years). The mfERGs elicited by a conventional CRT screen (S710, Compaq Computer Co.) were compared to those elicited by a studio-grade master OLED monitor (PVM-1741, Sony, Japan) and a conventional LCD (S1721, Flexscan, Eizo Nanao Corp., Japan). The luminance changes of each monitor were measured with a photodiode. CRT, OLED, and LCD screens with a frame frequency of 60 Hz were studied. A hexagonal stimulus array with 61 stimulus elements was created on each monitor. The serial white stimuli of the OLED screen at 60 Hz did not fuse, and that of the LCD screens fused. The amplitudes of P1 and P2 of the first-order kernels of the mfERGs were not significantly different from those elicited by the CRT and OLED screens, and the P1 amplitude of the first-order kernel elicited by the LCD stimuli was significantly smaller than that elicited by the CRT in all the groups of the averaged hexagonal elements. The implicit times were approximately 10 ms longer in almost all components elicited by the LCD screen compared to those elicited by the CRT screen. The mfERGs elicited by monitors other than the CRT should be carefully interpreted, especially those elicited by LCD screens. The OLED had good performance, and we conclude that it can replace the CRT as a stimulator for mfERGs; however, a collection of normative data is recommended. © 2014 ARVO.
Kim, Hyo-Jun; Shin, Min-Ho; Lee, Jae-Yong; Kim, Ji-Hoon; Kim, Young-Joo
2017-05-15
An optically efficient liquid-crystal display (LCD) structure using a patterned quantum dot (QD) film and a short-pass filter (SPF) was proposed and fabricated. The patterned QD film contributed to the generation of 95% in the area ratio (or 90% in the coverage ratio) of the Rec. 2020 color gamut. This was achieved by avoiding the problem of interaction between white backlight and broad transmittance spectra of color filters (CFs) as seen in a conventional LCD with a mixed QD film as a reference. The patterned QD film can maintain the narrow bandwidth of the green and the red QD colors before passing through the CFs. Additionally, the optical intensities of the red, green, and blue spectra were enhanced to 1.63, 1.72, and 2.16 times the reference LCD values, respectively. This was a result of separated emission of the red and green patterned QD film and reflection of the red and green light to the forward direction by the SPF.
Choi, Dongchul; Hong, Sung-Jei; Son, Yongkeun
2014-11-27
In this study, indium-tin-oxide (ITO) nanoparticles were simply recovered from the thin film transistor-liquid crystal display (TFT-LCD) panel scraps by means of lift-off method. This can be done by dissolving color filter (CF) layer which is located between ITO layer and glass substrate. In this way the ITO layer was easily lifted off the glass substrate of the panel scrap without panel crushing. Over 90% of the ITO on the TFT-LCD panel was recovered by using this method. After separating, the ITO was obtained as particle form and their characteristics were investigated. The recovered product appeared as aggregates of particles less than 100 nm in size. The weight ratio of In/Sn is very close to 91/9. XRD analysis showed that the ITO nanoparticles have well crystallized structures with (222) preferred orientation even after recovery. The method described in this paper could be applied to the industrial recovery business for large size LCD scraps from TV easily without crushing the glass substrate.
Choi, Dongchul; Hong, Sung-Jei; Son, Yongkeun
2014-01-01
In this study, indium-tin-oxide (ITO) nanoparticles were simply recovered from the thin film transistor-liquid crystal display (TFT-LCD) panel scraps by means of lift-off method. This can be done by dissolving color filter (CF) layer which is located between ITO layer and glass substrate. In this way the ITO layer was easily lifted off the glass substrate of the panel scrap without panel crushing. Over 90% of the ITO on the TFT-LCD panel was recovered by using this method. After separating, the ITO was obtained as particle form and their characteristics were investigated. The recovered product appeared as aggregates of particles less than 100 nm in size. The weight ratio of In/Sn is very close to 91/9. XRD analysis showed that the ITO nanoparticles have well crystallized structures with (222) preferred orientation even after recovery. The method described in this paper could be applied to the industrial recovery business for large size LCD scraps from TV easily without crushing the glass substrate. PMID:28788267
Engineering of Semiconductor Nanocrystals for Light Emitting Applications
Todescato, Francesco; Fortunati, Ilaria; Minotto, Alessandro; Signorini, Raffaella; Jasieniak, Jacek J.; Bozio, Renato
2016-01-01
Semiconductor nanocrystals are rapidly spreading into the display and lighting markets. Compared with liquid crystal and organic LED displays, nanocrystalline quantum dots (QDs) provide highly saturated colors, wide color gamut, resolution, rapid response time, optical efficiency, durability and low cost. This remarkable progress has been made possible by the rapid advances in the synthesis of colloidal QDs and by the progress in understanding the intriguing new physics exhibited by these nanoparticles. In this review, we provide support to the idea that suitably engineered core/graded-shell QDs exhibit exceptionally favorable optical properties, photoluminescence and optical gain, while keeping the synthesis facile and producing QDs well suited for light emitting applications. Solid-state laser emitters can greatly profit from QDs as efficient gain materials. Progress towards fabricating low threshold, solution processed DFB lasers that are optically pumped using one- and two-photon absorption is reviewed. In the field of display technologies, the exploitation of the exceptional photoluminescence properties of QDs for LCD backlighting has already advanced to commercial levels. The next big challenge is to develop the electroluminescence properties of QD to a similar state. We present an overview of QLED devices and of the great perspectives for next generation display and lighting technologies. PMID:28773794
NASA Astrophysics Data System (ADS)
Parkhurst, J. M.; Price, G. J.; Sharrock, P. J.; Stratford, J.; Moore, C. J.
2013-04-01
Patient motion during treatment is well understood as a prime factor limiting radiotherapy success, with the risks most pronounced in modern safety critical therapies promising the greatest benefit. In this paper we describe a real-time visual feedback device designed to help patients to actively manage their body position, pose and motion. In addition to technical device details, we present preliminary trial results showing that its use enables volunteers to successfully manage their respiratory motion. The device enables patients to view their live body surface measurements relative to a prior reference, operating on the concept that co-operative engagement with patients will both improve geometric conformance and remove their perception of isolation, in turn easing stress related motion. The device is driven by a real-time wide field optical sensor system developed at The Christie. Feedback is delivered through three intuitive visualization modes of hierarchically increasing display complexity. The device can be used with any suitable display technology; in the presented study we use both personal video glasses and a standard LCD projector. The performance characteristics of the system were measured, with the frame rate, throughput and latency of the feedback device being 22.4 fps, 47.0 Mbps, 109.8 ms, and 13.7 fps, 86.4 Mbps, 119.1 ms for single and three-channel modes respectively. The pilot study, using ten healthy volunteers over three sessions, shows that the use of visual feedback resulted in both a reduction in the participants' respiratory amplitude, and a decrease in their overall body motion variability.
Studies to determine the effectiveness of longitudinal channelizing devices in work zones.
DOT National Transportation Integrated Search
2011-01-01
This report describes the methodology and results of analyses performed to determine whether the following longitudinal : channelizing device (LCD) applications improve the traffic safety and operations of work zones relative to the use of standard :...
Ring-shaped stain patterns driven by solute reactive mesogens in liquid crystal solution
NASA Astrophysics Data System (ADS)
Cha, Tae Woon; Bulliard, Xavier; Choi, Sang Gun; Lee, Hyoung Sub; Kong, Hyang-Shik; Han, Sang Youn
2014-07-01
We report on the formation of ring-shaped stain patterns in a polymer-stabilized patterned vertical alignment mode liquid crystal display (LCD) during the cell filling process. Through the interpretation of the formation mechanism, an effective way to control its development is provided. Systematic trace of the reactive mesogens reveals that the formation of patterns is strongly related to the segregation of solute mesogens in the stain area. These undesirable patterns can be avoided or controlled by reducing the drop volume at each droplet using an inkjet printing technique, meaning that the printing technique could be a useful solution in display technology. For the formation of ring-shaped patterns, the dragging of reactive mesogens during the spreading of the liquid crystal solution plays a key role in the closed LCD cell.
Visual Costs of the Inhomogeneity of Luminance and Contrast by Viewing LCD-TFT Screens Off-Axis.
Ziefle, Martina; Groeger, Thomas; Sommer, Dietmar
2003-01-01
In this study the anisotropic characteristics of TFT-LCD (Thin-Film-Transistor-Liquid Crystal Display) screens were examined. Anisotropy occurs as the distribution of luminance and contrast changes over the screen surface due to different viewing angles. On the basis of detailed photometric measurements the detection performance in a visual reaction task was measured in different viewing conditions. Viewing angle (0 degrees, frontal view; 30 degrees, off-axis; 50 degrees, off-axis) as well as ambient lighting (a dark or illuminated room) were varied. Reaction times and accuracy of detection performance were recorded. Results showed TFT's anisotropy to be a crucial factor deteriorating performance. With an increasing viewing angle performance decreased. It is concluded that TFT's anisotropy is a limiting factor for overall suitability and usefulness of this new display technology.
Human factors optimization of virtual environment attributes for a space telerobotic control station
NASA Astrophysics Data System (ADS)
Lane, Jason Corde
2000-10-01
Remote control of underwater vehicles and other robotic systems has, up until now, proved to be a challenging task for the human operator. With technology advancements in computers and displays, computer interfaces can be used to alleviate the workload on the operator. This research introduces the concept of a commanded display, which is a graphical simulation that shows the commands sent to the actual system in real-time. The primary goal of this research was to show a commanded display as an alternative to the traditional predictive display for reducing the effects of time delay. Several experiments were used to investigate how subjects compensated for time delay under a variety of conditions while controlling a 7-degree of freedom robotic manipulator. Results indicate that time delay increased completion time linearly; this linear relationship occurred even at different manipulator speeds, varying levels of error, and when using a commanded display. The commanded display alleviated the majority of time delay effects, up to 91% reduction. The commanded display also facilitated more accurate control, reducing the number of inadvertent impacts to the task worksite, even when compared to no time delay. Even with a moderate error between the commanded and actual displays, the commanded display was still a useful tool for mitigating time delay. The way subjects controlled the manipulator with the input device was tracked and their control strategies were extracted. A correlation between the subjects' use of the input device and their task completion time was determined. The importance of stereo vision and head tracking was examined and shown to improve a subject's depth perception within a virtual environment. Reports of simulator sickness induced by display equipment, including a head mounted display and LCD shutter glasses, were compared. The results of the above testing were used to develop an effective virtual environment control station to control a multi-arm robot.
NASA Astrophysics Data System (ADS)
Fan, Hang; Li, Kunyang; Zhou, Yangui; Liang, Haowen; Wang, Jiahui; Zhou, Jianying
2016-09-01
Recent upsurge on virtual and augmented realities (VR and AR) has re-ignited the interest to the immerse display technology. The VR/AR technology based on stereoscopic display is believed in its early stage as glasses-free, or autostereoscopic display, will be ultimately adopted for the viewing convenience, visual comfort and for the multi-viewer purposes. On the other hand, autostereoscopic display has not yet received positive market response for the past years neither with stereoscopic displays using shutter or polarized glasses. We shall present the analysis on the real-world applications, rigid user demand, the drawbacks to the existing barrier- and lenticular lens-based LCD autostereoscopy. We shall emphasize the emerging autostereoscopic display, and notably on directional backlight LCD technology using a hybrid spatial- and temporal-control scenario. We report the numerical simulation of a display system using Monte-Carlo ray-tracing method with the human retina as the real image receiver. The system performance is optimized using newly developed figure of merit for system design. The reduced crosstalk in an autostereoscopic system, the enhanced display quality, including the high resolution received by the retina, the display homogeneity without Moiré- and defect-pattern, will be highlighted. Recent research progress including a novel scheme for diffraction-free backlight illumination, the expanded viewing zone for autostereoscopic display, and the novel Fresnel lens array to achieve a near perfect display in 2D/3D mode will be introduced. The experimental demonstration will be presented to the autostereoscopic display with the highest resolution, low crosstalk, Moiré- and defect- pattern free.
NASA Astrophysics Data System (ADS)
Lo, Mei-Chun; Hsieh, Tsung-Hsien; Perng, Ruey-Kuen; Chen, Jiong-Qiao
2010-01-01
The aim of this research is to derive illuminant-independent type of HDR imaging modules which can optimally multispectrally reconstruct of every color concerned in high-dynamic-range of original images for preferable cross-media color reproduction applications. Each module, based on either of broadband and multispectral approach, would be incorporated models of perceptual HDR tone-mapping, device characterization. In this study, an xvYCC format of HDR digital camera was used to capture HDR scene images for test. A tone-mapping module was derived based on a multiscale representation of the human visual system and used equations similar to a photoreceptor adaptation equation, proposed by Michaelis-Menten. Additionally, an adaptive bilateral type of gamut mapping algorithm, using approach of a multiple conversing-points (previously derived), was incorporated with or without adaptive Un-sharp Masking (USM) to carry out the optimization of HDR image rendering. An LCD with standard color space of Adobe RGB (D65) was used as a soft-proofing platform to display/represent HDR original RGB images, and also evaluate both renditionquality and prediction-performance of modules derived. Also, another LCD with standard color space of sRGB was used to test gamut-mapping algorithms, used to be integrated with tone-mapping module derived.
Automatic calibration system for analog instruments based on DSP and CCD sensor
NASA Astrophysics Data System (ADS)
Lan, Jinhui; Wei, Xiangqin; Bai, Zhenlong
2008-12-01
Currently, the calibration work of analog measurement instruments is mainly completed by manual and there are many problems waiting for being solved. In this paper, an automatic calibration system (ACS) based on Digital Signal Processor (DSP) and Charge Coupled Device (CCD) sensor is developed and a real-time calibration algorithm is presented. In the ACS, TI DM643 DSP processes the data received by CCD sensor and the outcome is displayed on Liquid Crystal Display (LCD) screen. For the algorithm, pointer region is firstly extracted for improving calibration speed. And then a math model of the pointer is built to thin the pointer and determine the instrument's reading. Through numbers of experiments, the time of once reading is no more than 20 milliseconds while it needs several seconds if it is done manually. At the same time, the error of the instrument's reading satisfies the request of the instruments. It is proven that the automatic calibration system can effectively accomplish the calibration work of the analog measurement instruments.
Effects of color combination and ambient illumination on visual perception time with TFT-LCD.
Lin, Chin-Chiuan; Huang, Kuo-Chen
2009-10-01
An empirical study was carried out to examine the effects of color combination and ambient illumination on visual perception time using TFT-LCD. The effect of color combination was broken down into two subfactors, luminance contrast ratio and chromaticity contrast. Analysis indicated that the luminance contrast ratio and ambient illumination had significant, though small effects on visual perception. Visual perception time was better at high luminance contrast ratio than at low luminance contrast ratio. Visual perception time under normal ambient illumination was better than at other ambient illumination levels, although the stimulus color had a confounding effect on visual perception time. In general, visual perception time was better for the primary colors than the middle-point colors. Based on the results, normal ambient illumination level and high luminance contrast ratio seemed to be the optimal choice for design of workplace with video display terminals TFT-LCD.
Evaluation of parameters of color profile models of LCD and LED screens
NASA Astrophysics Data System (ADS)
Zharinov, I. O.; Zharinov, O. O.
2017-12-01
The purpose of the research relates to the problem of parametric identification of the color profile model of LCD (liquid crystal display) and LED (light emitting diode) screens. The color profile model of a screen is based on the Grassmann’s Law of additive color mixture. Mathematically the problem is to evaluate unknown parameters (numerical coefficients) of the matrix transformation between different color spaces. Several methods of evaluation of these screen profile coefficients were developed. These methods are based either on processing of some colorimetric measurements or on processing of technical documentation data.
In-TFT-Array-Process Micro Defect Inspection Using Nonlinear Principal Component Analysis
Liu, Yi-Hung; Wang, Chi-Kai; Ting, Yung; Lin, Wei-Zhi; Kang, Zhi-Hao; Chen, Ching-Shun; Hwang, Jih-Shang
2009-01-01
Defect inspection plays a critical role in thin film transistor liquid crystal display (TFT-LCD) manufacture, and has received much attention in the field of automatic optical inspection (AOI). Previously, most focus was put on the problems of macro-scale Mura-defect detection in cell process, but it has recently been found that the defects which substantially influence the yield rate of LCD panels are actually those in the TFT array process, which is the first process in TFT-LCD manufacturing. Defect inspection in TFT array process is therefore considered a difficult task. This paper presents a novel inspection scheme based on kernel principal component analysis (KPCA) algorithm, which is a nonlinear version of the well-known PCA algorithm. The inspection scheme can not only detect the defects from the images captured from the surface of LCD panels, but also recognize the types of the detected defects automatically. Results, based on real images provided by a LCD manufacturer in Taiwan, indicate that the KPCA-based defect inspection scheme is able to achieve a defect detection rate of over 99% and a high defect classification rate of over 96% when the imbalanced support vector machine (ISVM) with 2-norm soft margin is employed as the classifier. More importantly, the inspection time is less than 1 s per input image. PMID:20057957
NASA Astrophysics Data System (ADS)
Kakinuma, Koichiro
2006-05-01
The development of light-emitting diode (LED) backlight a wide-color-gamut and mercury-free has become active in liquid crystal display (LCD) industry. Reports on the development of backlights, such as a direct illumination-type back-light and a guided light illumination-type LED backlight were published. The fabrication of an actual commercial product has been progressing under this active development. Sony Corporation launched an LED-backlit LCD television (TV) model, dubbed QUALIA 005, the world’s first home-use television featuring LED backlighting. This product offers a very wide color reproduction range, delivering a color gamut of 150% of that typically achieved by conventional televisions. In this paper, the background of the development of the LED backlight system “TriluminosTM” and the technologies used to realize the wide color gamut are discussed. The main issues to be solved for the commercialization were how to reduce the brightness/color non uniformity of the backlight and how to treat heat generation from the LED. The standardization of wide color space definition xvYCC and LED backlight LCD television combination is expected to result in a more vivid and correct color expression, and a forecast that extends to the market in the future.
Lei, Chin-Nan; Whang, Liang-Ming; Chen, Po-Chun
2010-09-01
The amount of pollutants produced during manufacturing processes of thin-film transistor liquid crystal display (TFT-LCD) substantially increases due to an increasing production of the opto-electronic industry in Taiwan. This study presents the treatment performance of one aerobic and one anoxic/oxic (A/O) sequencing batch reactors (SBRs) treating synthetic TFT-LCD wastewater containing dimethyl sulfoxide (DMSO), monoethanolamine (MEA), and tetra-methyl ammonium hydroxide (TMAH). The long-term monitoring results for the aerobic and A/O SBRs demonstrate that stable biodegradation of DMSO, MEA, and TMAH can be achieved without any considerably adverse impacts. The ammonium released during MEA and TMAH degradation can also be completely oxidized to nitrate through nitrification in both SBRs. Batch studies on biodegradation rates for DMSO, MEA, and TMAH under anaerobic, anoxic, and aerobic conditions indicate that effective MEA degradation can be easily achieved under all three conditions examined, while efficient DMSO and TMAH degradation can be attained only under anaerobic and aerobic conditions, respectively. The potential odor problem caused by the formation of malodorous dimethyl sulfide from DMSO degradation under anaerobic conditions, however, requires insightful consideration in treating DMSO-containing wastewater. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Study on the waste liquid crystal display treatment: focus on the resource recovery.
Wang, Xinying; Lu, Xuebin; Zhang, Shuting
2013-01-15
A process combined pyrolysis and acid immersion was proposed in this study to dispose the hazardous liquid crystal display (LCD) waste for recovering valuable resources. The thermogravimetric (TG) analysis and fixed bed pyrolysis were investigated for the polarizing film that was separated from LCD. The results suggested the liquid product mainly contained acids, esters and aromatics should be upgraded such as hydrotreating process before used as industrial feedstock or fuel source. The gaseous product mainly consisted of H(2), CO, CO(2) and CH(4) can be used as a valuable fuel. The sulfuric acid immersion experiments were studied for recovering indium from the LCD glass after stripping the polarizing film. Central composite design (CCD) under response surface methodology (RSM) was used to optimize the acid immersion process and the results indicated the indium recovery can be fitted based on the actual value to a polynomial quadratic equation and the temperature was more essential factor than time and acid concentration in the studied ranges. The optimum processing condition was obtained with time 42.2 min, temperature 65.6 °C and acid concentration 0.6 mol/L. Under the optimal conditions, the indium recovery was close to 100%. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Ruixue; Chen, Ya; Xu, Zhenming
2015-05-19
Waste liquid crystal display (LCD) panels mainly contain inorganic materials (glass substrate) and organic materials (polarizing film and liquid crystal). The organic materials should be removed first since containing polarizing film and liquid crystal is to the disadvantage of the indium recycling process. In the present study, an efficient and environmentally friendly process to obtain acetic acid from waste LCD panels by sub/supercritical water treatments is investigated. Furthermore, a well-founded reaction mechanism is proposed. Several highlights of this study are summarized as follows: (i) 99.77% of organic matters are removed, which means the present technology is quite efficient to recycle the organic matters; (ii) a yield of 78.23% acetic acid, a quite important fossil energy based chemical product is obtained, which can reduce the consumption of fossil energy for producing acetic acid; (iii) supercritical water acts as an ideal solvent, a requisite reactant as well as an efficient acid-base catalyst, and this is quite significant in accordance with the "Principles of Green Chemistry". In a word, the organic matters of waste LCD panels are recycled without environmental pollution. Meanwhile, this study provides new opportunities for alternating fossil-based chemical products for sustainable development, converting "waste" into "fossil-based chemicals".
Chung, Jae-Moon; Zhang, Xiaokun; Shang, Fei; Kim, Ji-Hoon; Wang, Xiao-Lin; Liu, Shuai; Yang, Baoguo; Xiang, Yong
2018-05-29
To overcome the technological and economic obstacles of amorphous indium-gallium-zinc-oxide (a-IGZO)-based display backplane for industrial production, a clean etch-stopper (CL-ES) process is developed to fabricate a-IGZO-based thin film transistor (TFT) with improved uniformity and reproducibility on 8.5th generation glass substrates (2200 mm × 2500 mm). Compared with a-IGZO-based TFT with back-channel-etched (BCE) structure, a newly formed ES nano-layer (~ 100 nm) and a simultaneous etching of a-IGZO nano-layer (30 nm) and source-drain electrode layer are firstly introduced to a-IGZO-based TFT device with CL-ES structure to improve the uniformity and stability of device for large-area display. The saturation electron mobility of 8.05 cm 2 /V s and the V th uniformity of 0.72 V are realized on the a-IGZO-based TFT device with CL-ES structure. In the negative bias temperature illumination stress and positive bias thermal stress reliability testing under a ± 30 V bias for 3600 s, the measured V th shift of CL-ES-structured device significantly decreased to - 0.51 and + 1.94 V, which are much lower than that of BCE-structured device (- 3.88 V, + 5.58 V). The electrical performance of the a-IGZO-based TFT device with CL-ES structure implies that the economic transfer from a silicon-based TFT process to the metal oxide semiconductor-based process for LCD fabrication is highly feasible.
A portable device for detecting fruit quality by diffuse reflectance Vis/NIR spectroscopy
NASA Astrophysics Data System (ADS)
Sun, Hongwei; Peng, Yankun; Li, Peng; Wang, Wenxiu
2017-05-01
Soluble solid content (SSC) is a major quality parameter to fruit, which has influence on its flavor or texture. Some researches on the on-line non-invasion detection of fruit quality were published. However, consumers desire portable devices currently. This study aimed to develop a portable device for accurate, real-time and nondestructive determination of quality factors of fruit based on diffuse reflectance Vis/NIR spectroscopy (520-950 nm). The hardware of the device consisted of four units: light source unit, spectral acquisition unit, central processing unit, display unit. Halogen lamp was chosen as light source. When working, its hand-held probe was in contact with the surface of fruit samples thus forming dark environment to shield the interferential light outside. Diffuse reflectance light was collected and measured by spectrometer (USB4000). ARM (Advanced RISC Machines), as central processing unit, controlled all parts in device and analyzed spectral data. Liquid Crystal Display (LCD) touch screen was used to interface with users. To validate its reliability and stability, 63 apples were tested in experiment, 47 of which were chosen as calibration set, while others as prediction set. Their SSC reference values were measured by refractometer. At the same time, samples' spectral data acquired by portable device were processed by standard normalized variables (SNV) and Savitzky-Golay filter (S-G) to eliminate the spectra noise. Then partial least squares regression (PLSR) was applied to build prediction models, and the best predictions results was achieved with correlation coefficient (r) of 0.855 and standard error of 0.6033° Brix. The results demonstrated that this device was feasible to quantitatively analyze soluble solid content of apple.
An embedded system developed for hand held assay used in water monitoring
NASA Astrophysics Data System (ADS)
Wu, Lin; Wang, Jianwei; Ramakrishna, Bharath; Hsueh, Mingkai; Liu, Jonathan; Wu, Qufei; Wu, Chao-Cheng; Cao, Mang; Chang, Chein-I.; Jensen, Janet L.; Jensen, James O.; Knapp, Harlan; Daniel, Robert; Yin, Ray
2005-11-01
The US Army Joint Service Agent Water Monitor (JSAWM) program is currently interested in an approach that can implement a hardware- designed device in ticket-based hand-held assay (currently being developed) used for chemical/biological agent detection. This paper presents a preliminary investigation of the proof of concept. Three components are envisioned to accomplish the task. One is the ticket development which has been undertaken by the ANP, Inc. Another component is the software development which has been carried out by the Remote Sensing Signal and Image Processing Laboratory (RSSIPL) at the University of Maryland, Baltimore County (UMBC). A third component is an embedded system development which can be used to drive the UMBC-developed software to analyze the ANP-developed HHA tickets on a small pocket-size device like a PDA. The main focus of this paper is to investigate the third component that is viable and is yet to be explored. In order to facilitate to prove the concept, a flatbed scanner is used to replace a ticket reader to serve as an input device. The Stargate processor board is used as the embedded System with Embedded Linux installed. It is connected to an input device such as scanner as well as output devices such as LCD display or laptop etc. It executes the C-Coded processing program developed for this embedded system and outputs its findings on a display device. The embedded system to be developed and investigated in this paper is the core of a future hardware device. Several issues arising in such an embedded system will be addressed. Finally, the proof-of-concept pilot embedded system will be demonstrated.
ERIC Educational Resources Information Center
Yeung, Brendan; Ng, Tuck Wah; Tan, Han Yen; Liew, Oi Wah
2012-01-01
The use of different types of stains in the quantification of proteins separated on gels using electrophoresis offers the capability of deriving good outcomes in terms of linear dynamic range, sensitivity, and compatibility with specific proteins. An inexpensive, simple, and versatile lighting system based on liquid crystal display backlighting is…
The optical design of ultra-short throw system for panel emitted theater video system
NASA Astrophysics Data System (ADS)
Huang, Jiun-Woei
2015-07-01
In the past decade, the display format from (HD High Definition) through Full HD(1920X1080) to UHD(4kX2k), mainly guides display industry to two directions: one is liquid crystal display(LCD) from 10 inch to 100 inch and more, and the other is projector. Although LCD has been popularly used in market; however, the investment for production such kind displays cost more money expenditure, and less consideration of environmental pollution and protection[1]. The Projection system may be considered, due to more viewing access, flexible in location, energy saving and environmental protection issues. The topic is to design and fabricate a short throw factor liquid crystal on silicon (LCoS) projection system for cinema. It provides a projection lens system, including a tele-centric lens fitted for emitted LCoS to collimate light to enlarge the field angle. Then, the optical path is guided by a symmetric lens. Light of LCoS may pass through the lens, hit on and reflect through an aspherical mirror, to form a less distortion image on blank wall or screen for home cinema. The throw ratio is less than 0.33.
2013-10-17
The center of the Milky Way galaxy imaged by NASA Spitzer Space Telescope is displayed on a quarter-of-a-billion-pixel, high-definition 23-foot-wide 7-meter LCD science visualization screen at NASA Ames Research Center.
Development open source microcontroller based temperature data logger
NASA Astrophysics Data System (ADS)
Abdullah, M. H.; Che Ghani, S. A.; Zaulkafilai, Z.; Tajuddin, S. N.
2017-10-01
This article discusses the development stages in designing, prototyping, testing and deploying a portable open source microcontroller based temperature data logger for use in rough industrial environment. The 5V powered prototype of data logger is equipped with open source Arduino microcontroller for integrating multiple thermocouple sensors with their module, secure digital (SD) card storage, liquid crystal display (LCD), real time clock and electronic enclosure made of acrylic. The program for the function of the datalogger is programmed so that 8 readings from the thermocouples can be acquired within 3 s interval and displayed on the LCD simultaneously. The recorded temperature readings at four different points on both hydrodistillation show similar profile pattern and highest yield of extracted oil was achieved on hydrodistillation 2 at 0.004%. From the obtained results, this study achieved the objective of developing an inexpensive, portable and robust eight channels temperature measuring module with capabilities to monitor and store real time data.
The ergonomics approach for thin film transistor-liquid crystal display manufacturing process.
Lu, Chih-Wei; Yao, Chia-Chun; Kuo, Chein-Wen
2012-01-01
The thin film transistor-liquid crystal display (TFT-LCD) has been used all over the world. Although the manufacture process of TFT-LCD was highly automated, employees are hired to do manual job in module assembly process. The operators may have high risk of musculoskeletal disorders because of the long work hours and the repetitive activities in an unfitted work station. The tools of this study were questionnaire, checklist and to evaluate the work place design. The result shows that the participants reported high musculoskeletal disorder symptoms in shoulder (59.8%), neck (49.5%), wrist (39.5%), and upper back (30.6%). And, to reduce the ergonomic risk factors, revising the height of the work benches, chairs and redesigning the truck to decrease the chance of unsuitable positions were recommended and to reduce other ergonomics hazards and seta good human machine interface and appropriate job design.
Co-located haptic and 3D graphic interface for medical simulations.
Berkelman, Peter; Miyasaka, Muneaki; Bozlee, Sebastian
2013-01-01
We describe a system which provides high-fidelity haptic feedback in the same physical location as a 3D graphical display, in order to enable realistic physical interaction with virtual anatomical tissue during modelled procedures such as needle driving, palpation, and other interventions performed using handheld instruments. The haptic feedback is produced by the interaction between an array of coils located behind a thin flat LCD screen, and permanent magnets embedded in the instrument held by the user. The coil and magnet configuration permits arbitrary forces and torques to be generated on the instrument in real time according to the dynamics of the simulated tissue by activating the coils in combination. A rigid-body motion tracker provides position and orientation feedback of the handheld instrument to the computer simulation, and the 3D display is produced using LCD shutter glasses and a head-tracking system for the user.
Secure information display with limited viewing zone by use of multi-color visual cryptography.
Yamamoto, Hirotsugu; Hayasaki, Yoshio; Nishida, Nobuo
2004-04-05
We propose a display technique that ensures security of visual information by use of visual cryptography. A displayed image appears as a completely random pattern unless viewed through a decoding mask. The display has a limited viewing zone with the decoding mask. We have developed a multi-color encryption code set. Eight colors are represented in combinations of a displayed image composed of red, green, blue, and black subpixels and a decoding mask composed of transparent and opaque subpixels. Furthermore, we have demonstrated secure information display by use of an LCD panel.
Lower bound for LCD image quality
NASA Astrophysics Data System (ADS)
Olson, William P.; Balram, Nikhil
1996-03-01
The paper presents an objective lower bound for the discrimination of patterns and fine detail in images on a monochrome LCD. In applications such as medical imaging and military avionics the information of interest is often at the highest frequencies in the image. Since LCDs are sampled data systems, their output modulation is dependent on the phase between the input signal and the sampling points. This phase dependence becomes particularly significant at high spatial frequencies. In order to use an LCD for applications such as those mentioned above it is essential to have a lower (worst case) bound on the performance of the display. We address this problem by providing a mathematical model for the worst case output modulation of an LCD in response to a sine wave input. This function can be interpreted as a worst case modulation transfer function (MTF). The intersection of the worst case MTF with the contrast threshold function (CTF) of the human visual system defines the highest spatial frequency that will always be detectable. In addition to providing the worst case limiting resolution, this MTF is combined with the CTF to produce objective worst case image quality values using the modulation transfer function area (MTFA) metric.
Low vision system for rapid near- and far-field magnification switching.
Ambrogi, Nicholas; Dias-Carlson, Rachel; Gantner, Karl; Gururaj, Anisha; Hanumara, Nevan; Narain, Jaya; Winter, Amos; Zielske, Iris; Satgunam, PremNandhini; Bagga, Deepak Kumar; Gothwal, Vijaya
2015-01-01
People suffering from low vision, a condition caused by a variety of eye-related diseases and/or disorders, find their ability to read greatly improved when text is magnified between 2 and 6 times. Assistive devices currently on the market are either geared towards reading text far away (~20 ft.) or very near (~2 ft.). This is a problem especially for students suffering from low vision, as they struggle to flip their focus between the chalkboard (far-field) and their notes (near- field). A solution to this problem is of high interest to eye care facilities in the developing world - no devices currently exist that have the aforementioned capabilities at an accessible price point. Through consultation with specialists at L.V. Prasad Eye Institute in India, the authors propose, design and demonstrate a device that fills this need, directed primarily at the Indian market. The device utilizes available hardware technologies to electronically capture video ahead of the user and zoom and display the image in real-time on LCD screens mounted in front of the user's eyes. This design is integrated as a wearable system in a glasses form-factor.
Newell, Matthew R [Los Alamos, NM; Jones, David Carl [Los Alamos, NM
2009-09-01
A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.
Lewicka, Małgorzata; Henrykowska, Gabriela; Zawadzka, Magdalena; Rutkowski, Maciej; Pacholski, Krzysztof; Buczyński, Andrzej
2017-07-14
The increasing number of devices emitting electromagnetic radiation (EMR) in people's everyday life attracted the attention of researchers because of possible adverse effects of this factor on living organisms. One of the EMR effect may be peroxidation of lipid membranes formed as a result of free radical process. The article presents the results of in vitro studies aimed at identifying changes in malondialdehyde (MDA) concentration - a marker of lipid peroxidation and antioxidant role of vitamin A during the exposure of blood platelets to electromagnetic radiation generated by liquid-crystal-display (LCD) monitors. Electromagnetic radiation emitted by LCD monitors is characterized by parameters: 1 kHz frequency and 220 V/m intensity (15 cm from display screen). The time of exposure was 30 and 60 min. The study was conducted on porcine blood platelets. The samples were divided into 6 groups: unexposed to radiation, unexposed + vitamin A, exposed for 30 min, exposed for 30 min + vitamin A, exposed for 60 min, exposed for 60 min + vitamin A. The MDA concentration in blood platelets increases significantly as compared to control values after 60 min of exposure to EMR. A significant decrease in MDA concentration after the addition of vitamin A was noticed. In the blood samples exposed to EMR for 30 and 60 min the MDA concentration was significantly increased by addition of vitamin A. The results show the possibly negative effect of electromagnetic radiation on the cellular membrane structure manifested by changes in malondialdehyde concentration and indicate a possible protective role of vitamin A in this process. Int J Occup Med Environ Health 2017;30(5):695-703. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Grayscale standard display function on LCD color monitors
NASA Astrophysics Data System (ADS)
De Monte, Denis; Casale, Carlo; Albani, Luigi; Bonfiglio, Silvio
2007-03-01
Currently, as a rule, digital medical systems use monochromatic Liquid Crystal Display (LCD) monitors to ensure an accurate reproduction of the Grayscale Standard Display Function (GSDF) as specified in the Digital Imaging and Communications in Medicine (DICOM) Standard. As a drawback, special panels need to be utilized in digital medical systems, while it would be preferable to use regular color panels, which are manufactured on a wide scale and are thus available at by far lower prices. The method proposed introduces a temporal color dithering technique to accurately reproduce the GSDF on color monitors without losing monitor resolution. By exploiting the characteristics of the Human Visual System (HVS) the technique ensures that a satisfactory grayscale reproduction is achieved minimizing perceivable flickering and undesired color artifacts. The algorithm has been implemented in the monitor using a low-cost Field Programmable Gate Array (FPGA). Quantitative evaluations of luminance response on a 3 Mega-pixel color monitor have shown that the compliance with the GSDF can be achieved with the accuracy level required by medical applications. At the same time the measured color deviation is below the threshold perceivable by the human eye.
Probability of the moiré effect in barrier and lenticular autostereoscopic 3D displays.
Saveljev, Vladimir; Kim, Sung-Kyu
2015-10-05
The probability of the moiré effect in LCD displays is estimated as a function of angle based on the experimental data; a theoretical function (node spacing) is proposed basing on the distance between nodes. Both functions are close to each other. The connection between the probability of the moiré effect and the Thomae's function is also found. The function proposed in this paper can be used in the minimization of the moiré effect in visual displays, especially in autostereoscopic 3D displays.
High volume nanoscale roll-based imprinting using jet and flash imprint lithography
NASA Astrophysics Data System (ADS)
Ahn, Se Hyun; Miller, Michael; Yang, Shuqiang; Ganapathisubramanian, Maha; Menezes, Marlon; Singh, Vik; Wan, Fen; Choi, Jin; Xu, Frank; LaBrake, Dwayne; Resnick, Douglas J.; Hofemann, Paul; Sreenivasan, S. V.
2014-03-01
Extremely large-area roll-to-roll manufacturing on flexible substrates is ubiquitous for applications such as paper and plastic processing. The challenge is to extend this approach to the realm of nanopatterning and realize similar benefits. Display applications, including liquid crystal (LCD), organic light emitting diode (OLED) and flexible displays are particularly interesting because of the ability to impact multiple levels in the basic display. Of particular interest are the polarizer, DBEF, thin film transistor and color filter; roll-based imprinting has the opportunity to create high performance components within the display while improving the cost of ownership of the panel. Realization of these devices requires both a scalable imprinting technology and tool. In this paper, we introduce a high volume roll-based nanopatterning system, the LithoFlex 350TM. The LithoFlex 350 uses an inkjet based imprinting process similar to the technology demonstrator tool, the LithoFlex 100, introduced in 2012. The width of the web is 350mm and patterning width is 300mm. The system can be configured either for Plate-to-Roll (P2R) imprinting (in which a rigid template is used to pattern the flexible web material) or for Roll-to-Plate imprinting (R2P) (in which a web based template is used to pattern either wafers or panels). Also described in this paper are improvements to wire grid polarizer devices. By optimizing the deposition, patterning and etch processes, we have been able to create working WGPs with transmittance and extinction ratios as high as 44% and 50,000, respectively.
SSVEP-based BCI for manipulating three-dimensional contents and devices
NASA Astrophysics Data System (ADS)
Mun, Sungchul; Cho, Sungjin; Whang, Mincheol; Ju, Byeong-Kwon; Park, Min-Chul
2012-06-01
Brain Computer Interface (BCI) studies have been done to help people manipulate electronic devices in a 2D space but less has been done for a vigorous 3D environment. The purpose of this study was to investigate the possibility of applying Steady State Visual Evoked Potentials (SSVEPs) to a 3D LCD display. Eight subjects (4 females) ranging in age between 20 to 26 years old participated in the experiment. They performed simple navigation tasks on a simple 2D space and virtual environment with/without 3D flickers generated by a Flim-Type Patterned Retarder (FPR). The experiments were conducted in a counterbalanced order. The results showed that 3D stimuli enhanced BCI performance, but no significant effects were found due to the small number of subjects. Visual fatigue that might be evoked by 3D stimuli was negligible in this study. The proposed SSVEP BCI combined with 3D flickers can allow people to control home appliances and other equipment such as wheelchairs, prosthetics, and orthotics without encountering dangerous situations that may happen when using BCIs in real world. 3D stimuli-based SSVEP BCI would motivate people to use 3D displays and vitalize the 3D related industry due to its entertainment value and high performance.
Use of Linear and Circular Polarization: The Secret LCD Screen and 3D Cinema
NASA Astrophysics Data System (ADS)
Richtberg, Stefan; Girwidz, Raimund
2017-10-01
References to everyday life are important for teaching physics. Discussing polarization phenomena, liquid crystal displays (LCDs) and 3D cinemas provide such references. In this paper we describe experiments to support students' understanding of linearly polarized light as well as the phenomenon of inverted colors using a secret LCD screen. Moreover we explain how 3D glasses work (when using polarizers) and introduce some experiments to point out why 3D cinemas use circularly polarized light instead of linearly polarized light. When using linearly polarized light, viewers must keep their head level all the time. Using circularly polarized light, this is not necessary.
Seeded Fault Bearing Experiments: Methodology and Data Acquisition
2011-06-01
electronics piezoelectric ( IEPE ) transducer. Constant current biased transducers require AC coupling for the output signal. The ICP-Type Signal...the outer race I/O input/output IEPE integral electronics piezoelectric LCD liquid crystal display P&D Prognostics and Diagnostics RMS root
Nonlinear mapping of the luminance in dual-layer high dynamic range displays
NASA Astrophysics Data System (ADS)
Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi
2009-02-01
It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.
Assessment of toxic metals in waste personal computers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolias, Konstantinos; Hahladakis, John N., E-mail: john_chach@yahoo.gr; Gidarakos, Evangelos, E-mail: gidarako@mred.tuc.gr
Highlights: • Waste personal computers were collected and dismantled in their main parts. • Motherboards, monitors and plastic housing were examined in their metal content. • Concentrations measured were compared to the RoHS Directive, 2002/95/EC. • Pb in motherboards and funnel glass of devices released <2006 was above the limit. • Waste personal computers need to be recycled and environmentally sound managed. - Abstract: Considering the enormous production of waste personal computers nowadays, it is obvious that the study of their composition is necessary in order to regulate their management and prevent any environmental contamination caused by their inappropriate disposal.more » This study aimed at determining the toxic metals content of motherboards (printed circuit boards), monitor glass and monitor plastic housing of two Cathode Ray Tube (CRT) monitors, three Liquid Crystal Display (LCD) monitors, one LCD touch screen monitor and six motherboards, all of which were discarded. In addition, concentrations of chromium (Cr), cadmium (Cd), lead (Pb) and mercury (Hg) were compared with the respective limits set by the RoHS 2002/95/EC Directive, that was recently renewed by the 2012/19/EU recast, in order to verify manufacturers’ compliance with the regulation. The research included disassembly, pulverization, digestion and chemical analyses of all the aforementioned devices. The toxic metals content of all samples was determined using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The results demonstrated that concentrations of Pb in motherboards and funnel glass of devices with release dates before 2006, that is when the RoHS Directive came into force, exceeded the permissible limit. In general, except from Pb, higher metal concentrations were detected in motherboards in comparison with plastic housing and glass samples. Finally, the results of this work were encouraging, since concentrations of metals referred in the RoHS Directive were found in lower levels than the legislative limits.« less
NASA Astrophysics Data System (ADS)
Xie, Hongxing; Huang, Jiamin; Ye, Yun; Chen, Enguo; Xu, Sheng
2017-10-01
Light Guide Plate (LGP) plays an irreplaceable role in Liquid Crystal Display (LCD) backlight. LGP with quantum-dot (QD) shows promise in the development of next-generation displays because of QDs' beneficial characteristics. In this paper, we present a novel QD LGP for LCD backlight based on QD scattering microstructure array (SMA), in which the QD net dots are located discretely and arranged in arrays on the bottom surface of LGP. The paper first introduces the QD backlight briefly, then discusses the preparation and fabrication process of the proposed prototype, and finally presents a systematic photometric approach to reveal the remarkable advantages of QD backlight. The white-balance is achieved by adjusting the proportion of the QDs in the mixture and optimizing the R-QD / G-QD ratio. The apparent morphology of QD SMA is characterized by OLYMPUS laser microscope, while the optical properties of QD backlight are investigated by F-4600 fluorescence spectrophotometer and SRC-200M spectrum color luminance meter, respectively. Experimental results show that the white balance can be achieved when the QDs account for a certain proportion about 7% within the mixture, and the ratio of R-QD / G-QD is optimized to about 1:12. The proposed system offers an alternative and feasible method for fabricating QD backlight, which may have great application prospects in the future.
Realisation of a holographic microlaser scalpel using a digital micromirror device
NASA Astrophysics Data System (ADS)
Zwick, Susanne; Warber, Michael; Haist, Tobias; Osten, Wolfgang
2007-06-01
Modern spatial light modulators (SLM) enable the generation of more or less arbitrary light fields in three dimensions. Such light fields can be used for different future applications in the field of biomedical optics. One example is the processing/cutting of biological material on a microscopic scale. By displaying computer generated holograms by suitable SLMs it is possible to ablate complex structures into three-dimensional objects without scanning with very high accuracy on a microscopic scale. To effectively cut biological materials by light, pulsed ultraviolet light is preferable. We will present a combined setup of a holographic laser scalpel using a digital micromirror device (DMD) and holographic optical tweezers using a liquid crystal display (LCD). The setup enables to move and cut or process micro-scaled objects like biological cells or tissue in three dimensions with high accuracy and without any mechanical movements just by changing the hologram displayed by the SLMs. We will show that holograms can be used to compensate aberrations implemented by the DMD or other optical components of the setup. Also we can generate arbitrary light fields like stripes, circles or arbitrary curves. Additionally we will present results for the fast optimization of holograms for the system. In particular we will show results obtained by implementing iterative Fourier transform based algorithms on a standard consumer graphics board (Nvidia 8800GLX). By this approach we are able to compute more than 360 complex 2D FFTs (512 × 512 pixels) per second with floating point precision.
Flexure mechanism-based parallelism measurements for chip-on-glass bonding
NASA Astrophysics Data System (ADS)
Jung, Seung Won; Yun, Won Soo; Jin, Songwan; Kim, Bo Sun; Jeong, Young Hun
2011-08-01
Recently, liquid crystal displays (LCDs) have played vital roles in a variety of electronic devices such as televisions, cellular phones, and desktop/laptop monitors because of their enhanced volume, performance, and functionality. However, there is still a need for thinner LCD panels due to the trend of miniaturization in electronic applications. Thus, chip-on-glass (COG) bonding has become one of the most important aspects in the LCD panel manufacturing process. In this study, a novel sensor was developed to measure the parallelism between the tooltip planes of the bonding head and the backup of the COG main bonder, which has previously been estimated by prescale pressure films in industry. The sensor developed in this study is based on a flexure mechanism, and it can measure the total pressing force and the inclination angles in two directions that satisfy the quantitative definition of parallelism. To improve the measurement accuracy, the sensor was calibrated based on the estimation of the total pressing force and the inclination angles using the least-squares method. To verify the accuracy of the sensor, the estimation results for parallelism were compared with those from prescale pressure film measurements. In addition, the influence of parallelism on the bonding quality was experimentally demonstrated. The sensor was successfully applied to the measurement of parallelism in the COG-bonding process with an accuracy of more than three times that of the conventional method using prescale pressure films.
NASA Astrophysics Data System (ADS)
Shen, Chien-wen
2009-01-01
During the processes of TFT-LCD manufacturing, steps like visual inspection of panel surface defects still heavily rely on manual operations. As the manual inspection time of TFT-LCD manufacturing could range from 4 hours to 1 day, the reliability of time forecasting is thus important for production planning, scheduling and customer response. This study would like to propose a practical and easy-to-implement prediction model through the approach of Bayesian networks for time estimation of manual operated procedures in TFT-LCD manufacturing. Given the lack of prior knowledge about manual operation time, algorithms of necessary path condition and expectation-maximization are used for structural learning and estimation of conditional probability distributions respectively. This study also applied Bayesian inference to evaluate the relationships between explanatory variables and manual operation time. With the empirical applications of this proposed forecasting model, approach of Bayesian networks demonstrates its practicability and prediction accountability.
Stacked STN LCDs for true-color projection systems
NASA Astrophysics Data System (ADS)
Gulick, Paul E.; Conner, Arlie R.
1991-08-01
The demand for a true color LCD projection panel for use with standard overhead projectors has been around ever since the first monochrome OHP projection panel was introduced in 1986. The monochrome panels evolved along with the LCD technology from the first blue- and-yellow mode units to black-and-white with levels of gray, and to yellow-and-magenta panels with limited intermediate color shades known as pseudo-color. Finally, a novel solution has been implemented using a stack of custom designed STN panels, making possible true color LCD projection panels that are reasonably priced, available in high volume and quite acceptable in overall image quality. This stacked technology relies on the inherent birefringence colors of each layer to switch between white (passing all wavelengths) and a subtractive color primary (passing all wavelengths but red, green, or blue) so the full spectrum can be projected. Standard gray-scale techniques expand the displayable color palette to almost 5,000 colors and beyond. The same technology can also be applied to various self-contained projection architectures.
Optical residual stress measurement in TFT-LCD panels
NASA Astrophysics Data System (ADS)
Wang, Wei-Chung; Sung, Po-Chi
2017-06-01
The residual stress of the glass substrate might be one of causes to produce the non-uniform light distribution defect, i.e. Mura, in thin film transistor-liquid crystal display (TFT-LCD) panels. Glass is a birefringent material with very low birefringence. Furthermore, the thinner and thinner thickness request from the market makes the traditional photoelasticity almost impossible to measure the residual stresses produced in thin glass plates. Recently, a low-level stress measurement method called transmissivity extremities theory of photoelasticity (TEToP) was successfully developed to measure the residual stress in glass plate. Besides, to measure the stress of the glass plate in the TFT-LCD panel whose rear surface may has different kinds of coatings, an advanced reflection photoelasticity was also developed. In this paper, three commercially available glass plates with 0.33mm nominal thickness and three glass circular disks with different coatings were inspected to verify the feasibility of the TEToP and the advanced reflection photoelasticity, respectively.
Color calibration of liquid crystal displays
NASA Astrophysics Data System (ADS)
Cazes, Albert N.; Braudaway, Gordon W.; Christensen, James; Cordes, Michael; DeCain, Don; Lien, Shui-Chih A.; Mintzer, Frederick C.; Wright, Steven L.
1999-04-01
For more than a decade the Image Applications department at IBMs Watson Research Center has been involved in cultural and commercial imaging projects that demand high-fidelity color reproduction of precious objects like paintings, illuminated manuscripts or jewelry. Our primary display media have been high-resolution cathode ray tubes (CRT), but for the last three years our customers have been replacing them with liquid crystal displays (LCD). The color calibration model we have been using for the CRT is the one described in the literature. It assumes that the chromas of the primaries are independent of intensity, that the colors produced from them are additive and that the intensity of black is almost zero. We measured several models of LCDs and observed that they poorly satisfied these assumptions at medium to low intensities. This becomes noticeable if the image has dark areas or if the display is viewed under a weak ambient light. In this paper, we use a modified version of the CRT model to calibrate the LCD. First we measure four sets of red, green, blue and gray patches. THen we determine the correction factor needed to make, at each level,the sum of the primaries equal to the corresponding gray. Finally, we use these factors to modify the data of red, green and blue.
Sarnoff JND Vision Model for Flat-Panel Design
NASA Technical Reports Server (NTRS)
Brill, Michael H.; Lubin, Jeffrey
1998-01-01
This document describes adaptation of the basic Sarnoff JND Vision Model created in response to the NASA/ARPA need for a general-purpose model to predict the perceived image quality attained by flat-panel displays. The JND model predicts the perceptual ratings that humans will assign to a degraded color-image sequence relative to its nondegraded counterpart. Substantial flexibility is incorporated into this version of the model so it may be used to model displays at the sub-pixel and sub-frame level. To model a display (e.g., an LCD), the input-image data can be sampled at many times the pixel resolution and at many times the digital frame rate. The first stage of the model downsamples each sequence in time and in space to physiologically reasonable rates, but with minimum interpolative artifacts and aliasing. Luma and chroma parts of the model generate (through multi-resolution pyramid representation) a map of differences-between test and reference called the JND map, from which a summary rating predictor is derived. The latest model extensions have done well in calibration against psychophysical data and against image-rating data given a CRT-based front-end. THe software was delivered to NASA Ames and is being integrated with LCD display models at that facility,
Colour gamut enhancement with remote light conversion mechanism
NASA Astrophysics Data System (ADS)
Koseoglu, D.; Sezer, Y. S.; Karsli, K.
2018-01-01
The backlight unit spectrum of liquid crystal displays (LCD) directly affects the colour gamut. With the invention of GaN based blue light emitting diodes (LED), phosphors and quantum dots (QD) have gained considerable scientific interest due to their broad range of applications especially in lighting and display technologies. These phosphors and QDs are used to convert the blue light of the LEDs into white in general lighting. On the other hand, in display systems, they are used to generate red and green bands. There are different application methods such as on-chip and remote configurations. In this study, we concentrate on remote phosphor and QD backlight configurations where the light conversion is done away from the chips. In our display designs, we used GaN based blue LED lateral chips as an excitation source, on the other hand, light conversion layers were placed in backlight units as a thin film for the emission of green and red bands. The mixing ratios of these composite layers were arranged to match the emission spectrum of the blue LEDs and the light conversion layer to the colour filters of the LCD, so that the green, blue, and red bands efficiently widens the colour space. The results were also compared with the on-chip phosphor arrangements.
Chun, Hyeong Jin; Han, Yong Duk; Park, Yoo Min; Kim, Ka Ram; Lee, Seok Jae
2018-01-01
To overcome the time and space constraints in disease diagnosis via the biosensing approach, we developed a new signal-transducing strategy that can be applied to colorimetric optical biosensors. Our study is focused on implementation of a signal transduction technology that can directly translate the color intensity signals—that require complicated optical equipment for the analysis—into signals that can be easily counted with the naked eye. Based on the selective light absorption and wavelength-filtering principles, our new optical signaling transducer was built from a common computer monitor and a smartphone. In this signal transducer, the liquid crystal display (LCD) panel of the computer monitor served as a light source and a signal guide generator. In addition, the smartphone was used as an optical receiver and signal display. As a biorecognition layer, a transparent and soft material-based biosensing channel was employed generating blue output via a target-specific bienzymatic chromogenic reaction. Using graphics editor software, we displayed the optical signal guide patterns containing multiple polygons (a triangle, circle, pentagon, heptagon, and 3/4 circle, each associated with a specified color ratio) on the LCD monitor panel. During observation of signal guide patterns displayed on the LCD monitor panel using a smartphone camera via the target analyte-loaded biosensing channel as a color-filtering layer, the number of observed polygons changed according to the concentration of the target analyte via the spectral correlation between absorbance changes in a solution of the biosensing channel and color emission properties of each type of polygon. By simple counting of the changes in the number of polygons registered by the smartphone camera, we could efficiently measure the concentration of a target analyte in a sample without complicated and expensive optical instruments. In a demonstration test on glucose as a model analyte, we could easily measure the concentration of glucose in the range from 0 to 10 mM. PMID:29509682
Chun, Hyeong Jin; Han, Yong Duk; Park, Yoo Min; Kim, Ka Ram; Lee, Seok Jae; Yoon, Hyun C
2018-03-06
To overcome the time and space constraints in disease diagnosis via the biosensing approach, we developed a new signal-transducing strategy that can be applied to colorimetric optical biosensors. Our study is focused on implementation of a signal transduction technology that can directly translate the color intensity signals-that require complicated optical equipment for the analysis-into signals that can be easily counted with the naked eye. Based on the selective light absorption and wavelength-filtering principles, our new optical signaling transducer was built from a common computer monitor and a smartphone. In this signal transducer, the liquid crystal display (LCD) panel of the computer monitor served as a light source and a signal guide generator. In addition, the smartphone was used as an optical receiver and signal display. As a biorecognition layer, a transparent and soft material-based biosensing channel was employed generating blue output via a target-specific bienzymatic chromogenic reaction. Using graphics editor software, we displayed the optical signal guide patterns containing multiple polygons (a triangle, circle, pentagon, heptagon, and 3/4 circle, each associated with a specified color ratio) on the LCD monitor panel. During observation of signal guide patterns displayed on the LCD monitor panel using a smartphone camera via the target analyte-loaded biosensing channel as a color-filtering layer, the number of observed polygons changed according to the concentration of the target analyte via the spectral correlation between absorbance changes in a solution of the biosensing channel and color emission properties of each type of polygon. By simple counting of the changes in the number of polygons registered by the smartphone camera, we could efficiently measure the concentration of a target analyte in a sample without complicated and expensive optical instruments. In a demonstration test on glucose as a model analyte, we could easily measure the concentration of glucose in the range from 0 to 10 mM.
Hybridization of biomedical circuitry
NASA Technical Reports Server (NTRS)
Rinard, G. A.
1978-01-01
The design and fabrication of low power hybrid circuits to perform vital signs monitoring are reported. The circuits consist of: (1) clock; (2) ECG amplifier and cardiotachometer signal conditioner; (3) impedance pneumobraph and respiration rate processor; (4) hear/breath rate processor; (5) temperature monitor; and (6) LCD display.
NASA Astrophysics Data System (ADS)
Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.; Bech, Søren; Andersen, Jakob Dahl; Forchhammer, Søren
2015-01-01
This paper focuses on the influence of ambient light on the perceived quality of videos displayed on Liquid Crystal Display (LCD) with local backlight dimming. A subjective test assessing the quality of videos with two backlight dimming methods and three lighting conditions, i.e. no light, low light level (5 lux) and higher light level (60 lux) was organized to collect subjective data. Results show that participants prefer the method exploiting local dimming possibilities to the conventional full backlight but that this preference varies depending on the ambient light level. The clear preference for one method at the low light conditions decreases at the high ambient light, confirming that the ambient light significantly attenuates the perception of the leakage defect (light leaking through dark pixels). Results are also highly dependent on the content of the sequence, which can modulate the effect of the ambient light from having an important influence on the quality grades to no influence at all.
Ma, En; Xu, Zhenming
2013-12-15
In this study, a technology process including vacuum pyrolysis and vacuum chlorinated separation was proposed to convert waste liquid crystal display (LCD) panels into useful resources using self-design apparatuses. The suitable pyrolysis temperature and pressure are determined as 300°C and 50 Pa at first. The organic parts of the panels were converted to oil (79.10 wt%) and gas (2.93 wt%). Then the technology of separating indium was optimized by central composite design (CCD) under response surface methodology (RSM). The results indicated the indium recovery ratio was 99.97% when the particle size is less than 0.16 mm, the weight percentage of NH4Cl to glass powder is 50 wt% and temperature is 450°C. The research results show that the organic materials, indium and glass of LCD panel can be recovered during the recovery process efficiently and eco-friendly. Copyright © 2013 Elsevier B.V. All rights reserved.
Calibrated LCD/TFT stimulus presentation for visual psychophysics in fMRI.
Strasburger, H; Wüstenberg, T; Jäncke, L
2002-11-15
Standard projection techniques using liquid crystal (LCD) or thin-film transistor (TFT) technology show drastic distortions in luminance and contrast characteristics across the screen and across grey levels. Common luminance measurement and calibration techniques are not applicable in the vicinity of MRI scanners. With the aid of a fibre optic, we measured screen luminances for the full space of screen position and image grey values and on that basis developed a compensation technique that involves both luminance homogenisation and position-dependent gamma correction. By the technique described, images displayed to a subject in functional MRI can be specified with high precision by a matrix of desired luminance values rather than by local grey value.
Stereoscopic medical imaging collaboration system
NASA Astrophysics Data System (ADS)
Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji
2007-02-01
The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.
NASA Astrophysics Data System (ADS)
Chang, Shu-Hsuan; Chang, Yung-Cheng; Yang, Cheng-Hong; Chen, Jun-Rong; Kuo, Yen-Kuang
2006-02-01
Organic light-emitting diodes (OLEDs) have been extensively developed in the past few years. The OLED displays have advantages over other displays, such as CRT, LCD, and PDP in thickness, weight, brightness, response time, viewing angle, contrast, driving power, flexibility, and capability of self-emission. In this work, the optical and electronic properties of multilayer OLED devices are numerically studied with an APSYS (Advanced Physical Model of Semiconductor Devices) simulation program. Specifically, the emission and absorption spectra of the Alq 3, DCM, PBD, and SA light-emitting layers, and energy band diagrams, electron-hole recombination rates, and current-voltage characteristics of the simulated OLED devices, typically with a multilayer structure of metal/Alq 3/EML/TPD/ITO constructed by Lim et al., are investigated and compared to the experimental results. The physical models utilized in this work are similar to those presented by Ruhstaller et al. and Hoffmann et al. The simulated results indicate that the emission spectra of the Alq 3, DCM, PBD, and SA light-emitting layers obtained in this study are in good agreement with those obtained experimentally by Zugang et al. Optimization of the optical and electronic performance of the multilayer OLED devices are attempted. In order to further promote the research results, the whole numerical simulation process for optimizing the design of OLED devices has been applied to a project-based course of OLED device design to enhance the students' skills in photonics device design at the Graduate Institute of Photonics of National Changhua University of Education in Taiwan. In the meantime, the effectiveness of the course has been proved by various assessments. The application of the results is a useful point of reference for the research on photonics device design and engineering education. Therefore, it proffers a synthetic effect between innovation and practical application.
Using Temporal Fill Factor to Reduce Frame Reconstruction Rates
NASA Technical Reports Server (NTRS)
Larimer, James; Balram, Nikhil; Gille, Jennifer; Luszcz, Jeffery
1997-01-01
The newer active matrix display technologies such as TFT-LCD, DMD, PDP maintain their pixel values through the entire frame time, presenting a 100% temporal fill factor, in contrast to the duty cycle produced by the phosphor impulse response of the CRT. This sample-and-hold characteristic can be exploited to lower the displayed frame rate without affecting visual quality. The lower frame rate results in significantly lower transmission bandwidth, power, and cost.
Automated Cryocooler Monitor and Control System
NASA Technical Reports Server (NTRS)
Britcliffe, Michael J.; Hanscon, Theodore R.; Fowler, Larry E.
2011-01-01
A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.
Design of multifunction anti-terrorism robotic system based on police dog
NASA Astrophysics Data System (ADS)
You, Bo; Liu, Suju; Xu, Jun; Li, Dongjie
2007-11-01
Aimed at some typical constraints of police dogs and robots used in the areas of reconnaissance and counterterrorism currently, the multifunction anti-terrorism robotic system based on police dog has been introduced. The system is made up of two parts: portable commanding device and police dog robotic system. The portable commanding device consists of power supply module, microprocessor module, LCD display module, wireless data receiving and dispatching module and commanding module, which implements the remote control to the police dogs and takes real time monitor to the video and images. The police dog robotic system consists of microprocessor module, micro video module, wireless data transmission module, power supply module and offence weapon module, which real time collects and transmits video and image data of the counter-terrorism sites, and gives military attack based on commands. The system combines police dogs' biological intelligence with micro robot. Not only does it avoid the complexity of general anti-terrorism robots' mechanical structure and the control algorithm, but it also widens the working scope of police dog, which meets the requirements of anti-terrorism in the new era.
NASA Astrophysics Data System (ADS)
Hou, Ligang; Luo, Rengui; Wu, Wuchen
2006-11-01
This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.
[Universal electrogustometer EG-2].
Wałkanis, Andrzej; Czesak, Michał; Pleskacz, Witold A
2011-01-01
Electrogustometry is a method for taste diagnosis and measurement. The EG-2 project is being developed in cooperation between Warsaw University of Technology and Military institute of Medicine in Warsaw. The device is an evolution of the recent universal electrogustometer EG-1 prototype. Due to considerations and experiences acquired during prototype usage, many enhancements have been incorporated into device. The aim was to create an easy-to-use, portable, battery powered device, enabled for fast measurements. Developed electrogustometer is using innovative, low-power microprocessor system, which control whole device. User interface is based on 5.7" graphical LCD (Liquid Crystal Display) and touchscreen. It can be directly operated by finger or with optional stylus. Dedicated GUI (Graphical User Interface) offers simple, predefined measurements and advance settings of signal parameters. It is also possible to store measurements results and patients data in an internal memory. User interface is multilanguage. Signals for patients examinations, supplied with bipolar electrode, are generated by an on-board circuit using DDS (Direct-Digital Synthesis) and DAC (Digital-to-Analog Converter). Electrogustometer is able to generate DC, sinus, triangle or rectangle signals with current amplitude from 0 to 500 pA and frequency form 0 to 500 Hz. Device is designed for manual and automeasurement modes. By using USB (Universal Serial Bus) port it is possible to retrieve data stored in internal memory and charging of built-in Li-lon battery as a source of power.
MEMS- and LC-adaptive optics at the Naval Research Laboratory
NASA Astrophysics Data System (ADS)
Restaino, S. R.; Wilcox, C. C.; Martinez, T.; Andrews, J. R.; Santiago, F.; Payne, D. M.
2012-06-01
Adaptive Optics (AO) is an ensemble of techniques that aims at the remedial of the deleterious effects that the Earth's turbulent atmosphere induces on both imagery and signal gathering in real time. It has been over four decades since the first AO system was developed and tested. During this time important technological advances have changed profoundly the way that we think and develop AO systems. The use of Micro-Electro-Mechanical-Systems (MEMS) devices and Liquid Crystal Devices (LCD) has revolutionized these technologies making possible to go from very expensive, very large and power consuming systems to very compact and inexpensive systems. These changes have rendered AO systems useful and applicable in other fields ranging from medical imaging to industry. In this paper we will review the research efforts at the Naval research Laboratory (NRL) to develop AO systems based on both MEMs and LCD in order to produce more compact and light weight AO systems.
An integrated port camera and display system for laparoscopy.
Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E
2010-05-01
In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.
NASA Astrophysics Data System (ADS)
Zhou, Lei; Bai, Gui-Lin; Guo, Xin; Shen, Su; Ou, Qing-Dong; Fan, Yuan-Yuan
2018-05-01
We present a design approach to realizing a desired collimated planar incoherent light source (CPILS) by incorporating lenticular microlens arrays (LMLAs) onto the substrates of discrete white organic light-emitting diode (WOLED) light sources and demonstrate the effectiveness of this method in collimated light beam shaping and luminance enhancement simultaneously. The obtained collimated WOLED light source shows enhanced luminance by a factor of 2.7 compared with that of the flat conventional device at the normal polar angle and, more importantly, exhibits a narrowed angular emission with a full-width at half-maximum (FWHM) of ˜33.6°. We anticipate that the presented strategy could provide an alternative way for achieving the desired large scale CPILS, thereby opening the door to many potential applications, including LCD backlights, three-dimensional displays, car headlights, and so forth.
Bilirubin measurements in neonates
NASA Astrophysics Data System (ADS)
Newman, Gregory J.
2000-04-01
Infant Jaundice is a physiologic condition of elevated bilirubin in the tissue that affects nearly 60 percent of all term newborns and virtually 100 percent of premature infants. The high production of bilirubin in the newborn circulatory system and the inability of the immature liver to process and eliminate it case the condition. When the bilirubin levels rise, it starts to deposit in the baby's skin and in the brain. The deposits in the brain can cause neurologic impairment and death. The BiliCheck is a handheld, battery-powered device that measures the level of jaundice non-invasively using BioPhotonics at the point of care. The result is displayed on an LCD screen immediately, so physicians can now make treatment decision without waiting for results to return from the lab. The BiliCheck System has been marketed worldwide since April of 1998 and has received FDA clearance for use in the USA on pre-photo therapy infants in March of 1999.
Landslide early warning system prototype with GIS analysis indicates by soil movement and rainfall
NASA Astrophysics Data System (ADS)
Artha, Y.; Julian, E. S.
2018-01-01
The aim of this paper is developing and testing of landslide early warning system. The early warning system uses accelerometersas ground movement and tilt-sensing device and a water flow sensor. A microcentroller is used to process the input signal and activate the alarm. An LCD is used to display the acceleration in x,y and z axis. When the soil moved or shifted and rainfall reached 100 mm/day, the alarm rang and signal were sentto the monitoring center via a telemetry system.Data logging information and GIS spatial data can be monitored remotely as tables and graphics as well as in the form of geographical map with the help of web-GIS interface. The system were tested at Kampung Gerendong, Desa Putat Nutug, Kecamatan Ciseeng, Kabupaten Bogor. This area has 3.15 cumulative score, which mean vulnerable to landslide. The results show that the early warning system worked as planned.
Watanabe, Kumiko; Hara, Naoto; Kimijima, Masumi; Kotegawa, Yasue; Ohno, Koji; Arimoto, Ako; Mukuno, Kazuo; Hisahara, Satoru; Horie, Hidenori
2012-10-01
School children with myopia were trained using a visual stimulation device that generated an isolated blur stimulus on a visual target, with a constant retinal image size and constant brightness. Uncorrected visual acuity, cycloplegic refraction, axial length, dynamic accommodation and papillary reaction were measured to investigate the effectiveness of the training. There were 45 school children with myopia without any other ophthalmic diseases. The mean age of the children was 8.9 +/- 2.0 years (age range; 6-16)and the mean refraction was -1.56 +/- 0.58 D (mean +/- standard deviation). As a visual stimulus, a white ring on a black background with a constant ratio of visual target size to retinal image size, irrespective of the distance, was displayed on a liquid crystal display (LCD), and the LCD was quickly moved from a proximal to a distal position to produce an isolated blur stimulus. Training with this visual stimulus was carried out in the relaxation phase of accommodation. Uncorrected visual acuity, cycloplegic refraction, axial length, dynamic accommodation and pupillary reaction were investigated before training and every 3 months during the training. Of the 45 subjects, 42 (93%) could be trained for 3 consecutive months, 33 (73%) for 6 months, 23 (51%) for 9 months, and 21 (47%) for 12 months. The mean refraction decreased by 0.83 +/- 0.56 D (mean +/- standard deviation) and the mean axial length increased by 0.47 +/- 0.16 mm at 1 year, showing that the training bad some effect in improving the visual acuity. In the tests of the dynamic accommodative responses, the latency of the accommodative-phase decreased from 0.4 +/- 0.2 sec to 0.3 +/- 0.1 sec at 1 year, the gain of the accommodative-phase improved from 69.0 +/- 27.0% to 93.3 +/- 13.4%, the maximum speed of the accommodative-phase increased from 5.1 +/- 2.2 D/sec to 6.8 +/- 2.2 D/sec and the gain of the relaxation-phase significantly improved from 52.1 +/- 26.0% to 72.7 +/- 13.7% (corresponding t-test, p < 0.005). No significant changes were observed in the pupillary reaction. The training device was useful for improving the accommodative functions and accommodative excess, suggesting that it may be able to suppress the progression of low myopia, development of which is known to be strongly influenced by environmental factors.
Digital image forensics for photographic copying
NASA Astrophysics Data System (ADS)
Yin, Jing; Fang, Yanmei
2012-03-01
Image display technology has greatly developed over the past few decades, which make it possible to recapture high-quality images from the display medium, such as a liquid crystal display(LCD) screen or a printed paper. The recaptured images are not regarded as a separate image class in the current research of digital image forensics, while the content of the recaptured images may have been tempered. In this paper, two sets of features based on the noise and the traces of double JPEG compression are proposed to identify these recaptured images. Experimental results showed that our proposed features perform well for detecting photographic copying.
Full-Field Calibration of Color Camera Chromatic Aberration using Absolute Phase Maps.
Liu, Xiaohong; Huang, Shujun; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian
2017-05-06
The refractive index of a lens varies for different wavelengths of light, and thus the same incident light with different wavelengths has different outgoing light. This characteristic of lenses causes images captured by a color camera to display chromatic aberration (CA), which seriously reduces image quality. Based on an analysis of the distribution of CA, a full-field calibration method based on absolute phase maps is proposed in this paper. Red, green, and blue closed sinusoidal fringe patterns are generated, consecutively displayed on an LCD (liquid crystal display), and captured by a color camera from the front viewpoint. The phase information of each color fringe is obtained using a four-step phase-shifting algorithm and optimum fringe number selection method. CA causes the unwrapped phase of the three channels to differ. These pixel deviations can be computed by comparing the unwrapped phase data of the red, blue, and green channels in polar coordinates. CA calibration is accomplished in Cartesian coordinates. The systematic errors introduced by the LCD are analyzed and corrected. Simulated results show the validity of the proposed method and experimental results demonstrate that the proposed full-field calibration method based on absolute phase maps will be useful for practical software-based CA calibration.
Automated optical inspection of liquid crystal display anisotropic conductive film bonding
NASA Astrophysics Data System (ADS)
Ni, Guangming; Du, Xiaohui; Liu, Lin; Zhang, Jing; Liu, Juanxiu; Liu, Yong
2016-10-01
Anisotropic conductive film (ACF) bonding is widely used in the liquid crystal display (LCD) industry. It implements circuit connection between screens and flexible printed circuits or integrated circuits. Conductive microspheres in ACF are key factors that influence LCD quality, because the conductive microspheres' quantity and shape deformation rate affect the interconnection resistance. Although this issue has been studied extensively by prior work, quick and accurate methods to inspect the quality of ACF bonding are still missing in the actual production process. We propose a method to inspect ACF bonding effectively by using automated optical inspection. The method has three steps. The first step is that it acquires images of the detection zones using a differential interference contrast (DIC) imaging system. The second step is that it identifies the conductive microspheres and their shape deformation rate using quantitative analysis of the characteristics of the DIC images. The final step is that it inspects ACF bonding using a back propagation trained neural network. The result shows that the miss rate is lower than 0.1%, and the false inspection rate is lower than 0.05%.
NASA Astrophysics Data System (ADS)
Zuo, Chao; Sun, Jiasong; Feng, Shijie; Hu, Yan; Chen, Qian
2016-03-01
Programmable colored illumination microscopy (PCIM) has been proposed as a flexible optical staining technique for microscopic contrast enhancement. In this method, we replace the condenser diaphragm of a conventional microscope with a programmable thin film transistor-liquid crystal display (TFT-LCD). By displaying different patterns on the LCD, numerous established imaging modalities can be realized, such as bright field, dark field, phase contrast, oblique illumination, and Rheinberg illuminations, which conventionally rely on intricate alterations in the respective microscope setups. Furthermore, the ease of modulating both the color and the intensity distribution at the aperture of the condenser opens the possibility to combine multiple microscopic techniques, or even realize completely new methods for optical color contrast staining, such as iridescent dark-field and iridescent phase-contrast imaging. The versatility and effectiveness of PCIM is demonstrated by imaging of several transparent colorless specimens, such as unstained lung cancer cells, diatom, textile fibers, and a cryosection of mouse kidney. Finally, the potentialities of PCIM for RGB-splitting imaging with stained samples are also explored by imaging stained red blood cells and a histological section.
[The design of a cardiac monitoring and analysing system with low power consumption].
Chen, Zhen-cheng; Ni, Li-li; Zhu, Yan-gao; Wang, Hong-yan; Ma, Yan
2002-07-01
The paper deals with a portable analyzing monitor system with liquid crystal display (LCD), which is low in power consumption and suitable for China's specific conditions. Apart from the development of the overall scheme of the system, the paper introduces the design of the hardware and the software. The 80196 single chip microcomputer is used as the central microprocessor to process and real-time electrocardiac signal data. The system have the following functions: five types of arrhythmia analysis, alarm, freeze, and record of automatic paperfeeding. The portable system can be operated by alternate-current (AC) or direct-current (DC). Its hardware circuit is simplified and its software structure is optimized. Multiple low power consumption and LCD unit are adopted in its modular designs.
Key product development based on cyclo olefin polymer for LCD-TV
NASA Astrophysics Data System (ADS)
Konishi, Yuichiro; Kobayashi, Masahi; Arakawa, Kouhei
2006-09-01
Cyclo Olefin Polymer (COP), which was developed by Zeon Corporation, is well known and used as an optical plastic in optical markets, having unique properties such as high light transmission, low water absorption, low birefringence etc. Optes Inc, who is ZEON CORPORATION's affiliate optical parts manufacturer, has succeeded in the development of high performance optical base films. These are used for retardation and polarizing films in LCD's (Liquid Crystal Displays), made from Cyclo Olefin Polymer with own film extrusion technologies. The Optical base film developed by Optes Inc has superior properties compared with those of existing products such as polycarbonate (PC), polyethylene terephthalate (PET) and Triacetate Cellulose (TAC) base in terms of low birefringence, high optical isotropy and high dimensional stability under high humidity and temperature conditions.
Inexpensive, Robust Water Stage Sensor for Rural Community Footbridges
NASA Astrophysics Data System (ADS)
Bradley, A.; McDermot, D. J.; Langenfeld, K.; Kruger, A.; Niemeier, J. J.
2014-12-01
Footbridges across streams and rivers provide rural communities in many countries essential access to hospitals, schools, and economic opportunities. Without these, communities experience isolation during the rainy season. However, many of these bridges are subject to immersion at times, and there is a need for sensing the river stage before venturing onto a bridge. We have developed an inexpensive, robust, self-contained sensor that meets this need. A two-wire electrical cord, purchased in bulk from a home improvement supplier, is the basic sensing element. The two conductors of the cord form a transmission line capacitor. The cord is suspended below the footbridge and the capacitance is a function of the fraction of the electrical cord that is immersed in water. The cord/capacitor is part of the timing element of an electronic oscillator circuit. As the water level rises, the capacitance and oscillator frequency decrease. The oscillator frequency is measured with a microcontroller. The microcontroller calculates the corresponding water stage and displays it on a small LCD display. The electronics are contained in a 12×7×7 cm watertight container. Four AA batteries power the sensor. The device has calibration features to accommodate different types of electrical cord.
48 CFR 52.223-16 - Acquisition of EPEAT-Registered Personal Computer Products.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) and liquid crystal display (LCD). Desktop computer means a computer where the main unit is intended to... periods of time either with or without a direct connection to an AC power source. Notebooks must utilize... products that, at the time of submission of proposals and at the time of award, were EPEAT® bronze...
Construction and Characterization of a Compact, Portable, Low-Cost Colorimeter for the Chemistry Lab
ERIC Educational Resources Information Center
Clippard, Carrie M.; Hughes, William; Chohan, Balwant S.; Sykes, Danny G.
2016-01-01
A low-cost and portable colorimeter was constructed featuring a low-voltage programmable color light sensor-to-frequency converter, a CMOS 8-bit microcontroller, and an LCD display. The instrument has successfully facilitated the introduction and application of spectroscopy to groups of middle school, high school, and undergraduate students. A…
A calibration method for fringe reflection technique based on the analytical phase-slope description
NASA Astrophysics Data System (ADS)
Wu, Yuxiang; Yue, Huimin; Pan, Zhipeng; Liu, Yong
2018-05-01
The fringe reflection technique (FRT) has been one of the most popular methods to measure the shape of specular surface these years. The existing system calibration methods of FRT usually contain two parts, which are camera calibration and geometric calibration. In geometric calibration, the liquid crystal display (LCD) screen position calibration is one of the most difficult steps among all the calibration procedures, and its accuracy is affected by the factors such as the imaging aberration, the plane mirror flatness, and LCD screen pixel size accuracy. In this paper, based on the deduction of FRT analytical phase-slope description, we present a novel calibration method with no requirement to calibrate the position of LCD screen. On the other hand, the system can be arbitrarily arranged, and the imaging system can either be telecentric or non-telecentric. In our experiment of measuring the 5000mm radius sphere mirror, the proposed calibration method achieves 2.5 times smaller measurement error than the geometric calibration method. In the wafer surface measuring experiment, the measurement result with the proposed calibration method is closer to the interferometer result than the geometric calibration method.
Measurement techniques of LC display systems
NASA Astrophysics Data System (ADS)
Kosmowski, Bogdan B.; Becker, Michael E.; Neumeier, Juergen
1993-10-01
The strong increase of applications of liquid crystal displays in various areas (measuring, medical equipment, automotive, telecommunication, office, etc.) has forced the demand for the adequate specification of the LCDs performances. The optical, electro-optical and spectral properties of LCDs are strongly dependent on viewing direction, electrical driving conditions, illumination and temperature. All these quantities have to be precisely controlled, when one of them is varied, the resulting optical response of the object is recorded. In this paper we present measuring methods proposed for LCD panels and the computer controlled measuring system (DMS) for their evaluation.
NASA Astrophysics Data System (ADS)
Ahmad, Nabihah; Rifen, A. Aminurdin M.; Helmy Abd Wahab, Mohd
2016-11-01
Automated Teller Machine (ATM) is an electronic banking outlet that allows bank customers to complete a banking transactions without the aid of any bank official or teller. Several problems are associated with the use of ATM card such card cloning, card damaging, card expiring, cast skimming, cost of issuance and maintenance and accessing customer account by third parties. The aim of this project is to give a freedom to the user by changing the card to biometric security system to access the bank account using Advanced Encryption Standard (AES) algorithm. The project is implemented using Field Programmable Gate Array (FPGA) DE2-115 board with Cyclone IV device, fingerprint scanner, and Multi-Touch Liquid Crystal Display (LCD) Second Edition (MTL2) using Very High Speed Integrated Circuit Hardware (VHSIC) Description Language (VHDL). This project used 128-bits AES for recommend the device with the throughput around 19.016Gbps and utilized around 520 slices. This design offers a secure banking transaction with a low rea and high performance and very suited for restricted space environments for small amounts of RAM or ROM where either encryption or decryption is performed.
Measurement of luminance noise and chromaticity noise of LCDs with a colorimeter and a color camera
NASA Astrophysics Data System (ADS)
Roehrig, H.; Dallas, W. J.; Krupinski, E. A.; Redford, Gary R.
2007-09-01
This communication focuses on physical evaluation of image quality of displays for applications in medical imaging. In particular we were interested in luminance noise as well as chromaticity noise of LCDs. Luminance noise has been encountered in the study of monochrome LCDs for some time, but chromaticity noise is a new type of noise which has been encountered first when monochrome and color LCDs were compared in an ROC study. In this present study one color and one monochrome 3 M-pixel LCDs were studied. Both were DICOM calibrated with equal dynamic range. We used a Konica Minolta Chroma Meter CS-200 as well as a Foveon color camera to estimate luminance and chrominance variations of the displays. We also used a simulation experiment to estimate luminance noise. The measurements with the colorimeter were consistent. The measurements with the Foveon color camera were very preliminary as color cameras had never been used for image quality measurements. However they were extremely promising. The measurements with the colorimeter and the simulation results showed that the luminance and chromaticity noise of the color LCD were larger than that of the monochrome LCD. Under the condition that an adequate calibration method and image QA/QC program for color displays are available, we expect color LCDs may be ready for radiology in very near future.
Image quality evaluation of medical color and monochrome displays using an imaging colorimeter
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Gu, Xiliang; Fan, Jiahua
2012-10-01
The purpose of this presentation is to demonstrate the means which permit examining the accuracy of Image Quality with respect to MTF (Modulation Transfer Function) and NPS (Noise Power Spectrum) of Color Displays and Monochrome Displays. Indications were in the past that color displays could affect the clinical performance of color displays negatively compared to monochrome displays. Now colorimeters like the PM-1423 are available which have higher sensitivity and color accuracy than the traditional cameras like CCD cameras. Reference (1) was not based on measurements made with a colorimeter. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future SPIE Conference.Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future Annual SPIE Conference. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. The Imaging Colorimeter. Measurement of color image quality needs were done with an imaging colorimeter as it is shown below. Imaging colorimetry is ideally suited to FPD measurement because imaging systems capture spatial data generating millions of data points in a single measurement operation. The imaging colorimeter which was used was the PM-1423 from Radiant Imaging. It uses full-frame CCDs with 100% fill factor which makes it very suitable to measure luminance and chrominance of individual LCD pixels and sub-pixels on an LCD display. The CCDs used are 14-bit thermoelectrically cooled and temperature stabilized , scientific grade.
Application of holographic elements in displays and planar illuminators
NASA Astrophysics Data System (ADS)
Putilin, Andrew; Gustomiasov, Igor
2007-05-01
Holographic Optical Elements (HOE's) on planar waveguides can be used to design the planar optics for backlit units, color selectors or filters, lenses for virtual reality displays. The several schemes for HOE recording are proposed to obtain planar stereo backlit unit and private eye displays light source. It is shown in the paper that the specific light transformation grating permits to construct efficient backlit units for display holograms and LCD. Several schemes of reflection/transmission backlit units and scattering films based on holographic optical elements are also proposed. The performance of the waveguide HOE can be optimized using the parameters of recording scheme and etching parameters. The schemes of HOE application are discussed and some experimental results are shown.
NASA Astrophysics Data System (ADS)
Aiken, John Charles
The development of a colour Spatial Light Modulator (SLM) and its application to optical information processing is described. Whilst monochrome technology has been established for many years, this is not the case for colour where commercial systems are unavailable. A main aspect of this study is therefore, how the use of colour can add an additional dimension to optical information processing. A well established route to monochrome system development has been the use of (black and white) liquid crystal televisions (LCTV) as SLM, providing useful performance at a low-cost. This study is based on the unique use of a colour display removed from a LCTV and operated as a colour SLM. A significant development has been the replacement of the original TV electronics operating the display with enhanced drive electronics specially developed for this application. Through a computer interface colour images from a drawing package or video camera can now be readily displayed on the LCD as input to an optical system. A detailed evaluation of the colour LCD optical properties, indicates that the new drive electronics have considerably improved the operation of the display for use as a colour SLM. Applications are described employing the use of colour in Fourier plane filtering, image correlation and speckle metrology. The SLM (and optical system) developed demonstrates, how the addition of colour has greatly enhanced its capabilities to implement principles of optical data processing, conventionally performed monochromatically. The hybrid combination employed, combining colour optical data processing with electronic techniques has resulted in a capable development system. Further development of the system using current colour LCDs and the move towards a portable system, is considered in the study conclusion.
Projection display technologies for the new millennium
NASA Astrophysics Data System (ADS)
Kahn, Frederic J.
2000-04-01
Although analog CRTs continue to enable most of the world's electronic projection displays such as US consumer rear projection televisions, discrete pixel (digital) active matrix LCD and DLP reflective mirror array projectors have rapidly created large nonconsumer markets--primarily for business. Recent advances in image quality, compactness and cost effectiveness of digital projectors have the potential to revolutionize major consumer and entertainment markets as well. Digital penetration of the mainstream consumer projection TV market will begin in the hear 2000. By 2005 digital projection HDTVs could take the major share of the consumer HDTV projection market. Digital projection is expected to dominate both the consumer HDTV and the cinema market by 2010, resulting in potential shipments for all projection markets exceeding 10 M units per year. Digital projection is improving at a rate 10X faster than analog CRT projectors and 5X faster than PDP flat panels. Continued rapid improvement of digital projection is expected due to its relative immaturity and due to the wide diversity of technological improvements being pursued. Key technology enablers are the imaging panels, light sources and micro-optics. Market shares of single panel projectors, MEMs panels, LCOS panels and low T p-Si TFT LCD panel variants are expected to increase.
Rigorous analysis of an electric-field-driven liquid crystal lens for 3D displays
NASA Astrophysics Data System (ADS)
Kim, Bong-Sik; Lee, Seung-Chul; Park, Woo-Sang
2014-08-01
We numerically analyzed the optical performance of an electric field driven liquid crystal (ELC) lens adopted for 3-dimensional liquid crystal displays (3D-LCDs) through rigorous ray tracing. For the calculation, we first obtain the director distribution profile of the liquid crystals by using the Erickson-Leslie motional equation; then, we calculate the transmission of light through the ELC lens by using the extended Jones matrix method. The simulation was carried out for a 9view 3D-LCD with a diagonal of 17.1 inches, where the ELC lens was slanted to achieve natural stereoscopic images. The results show that each view exists separately according to the viewing position at an optimum viewing distance of 80 cm. In addition, our simulation results provide a quantitative explanation for the ghost or blurred images between views observed from a 3D-LCD with an ELC lens. The numerical simulations are also shown to be in good agreement with the experimental results. The present simulation method is expected to provide optimum design conditions for obtaining natural 3D images by rigorously analyzing the optical functionalities of an ELC lens.
Spatial noise and threshold contrasts in LCD displays
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Krupinski, Elizabeth A.; Chawla, Amarpreet S.; Fan, Jiahua; Gandhi, Kunal
2003-05-01
This paper presents the results of initial physical and psycho-physical evaluations of the noise of high resolution LCDs. 5 LCDs were involved, having 4 different pixel structures. Spatial as well as temporal noise was physically measured with the aid of a high-performance CCD camera. Human contrast sensitivity in the presence of spatial noise was determined psycho-physically using periodic stimuli (square-wave patterns) as well as aperiodic stimuli (squares). For the measurements of the human contrast sensitivity, all LCDs were calibrated to the DICOM 14 Grayscale Standard Display Function (GSDF). The results demonstrate that spatial noise is the dominant noise in all LCDs, while temporal noise is insignificant and plays only a minor part. The magnitude of spatial noise of LCDs is in the range between that of CRTs with a P104 and that of CRTs with a P45. Of particular importance with respect to LCD noise is the contribution of the pixel structure to the Noise Power Spectrum, which shows up as sharp spikes at spatial frequencies beyond the LCDs" Nyquist frequency. The paper does not offer any clues about the importance of these spikes on the human contrast sensitivity.
Studies of the field-of-view resolution tradeoff in virtual-reality systems
NASA Technical Reports Server (NTRS)
Piantanida, Thomas P.; Boman, Duane; Larimer, James; Gille, Jennifer; Reed, Charles
1992-01-01
Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.
Remote CT reading using an ultramobile PC and web-based remote viewing over a wireless network.
Choi, Hyuk Joong; Lee, Jeong Hun; Kang, Bo Seung
2012-01-01
We developed a new type of mobile teleradiology system using an ultramobile PC (UMPC) for web-based remote viewing over a wireless network. We assessed the diagnostic performance of this system for abdominal CT interpretation. Performance was compared with an emergency department clinical monitor using a DICOM viewer. A total of 100 abdominal CT examinations were presented to four observers. There were 56 examinations showing appendicitis and 44 which were normal. The observers viewed the images using a UMPC display and an LCD monitor and rated each examination on a five-point scale. Receiver operating characteristics (ROC) analysis was used to test for differences. The sensitivity and specificities of all observers were similarly high. The average area under the ROC curve for readings performed on the UMPC and the LCD monitor was 0.959 and 0.976, respectively. There were no significant differences between the two display systems for interpreting abdominal CTs. The web-based mobile teleradiology system appears to be feasible for reading abdominal CTs for diagnosing appendicitis and may be valuable in emergency teleconsultation. Copyright © 2012 by the Royal Society of Medicine Press Ltd
NASA Astrophysics Data System (ADS)
Eichenlaub, Jesse B.
1995-03-01
Mounting a lenticular lens in front of a flat panel display is a well known, inexpensive, and easy way to create an autostereoscopic system. Such a lens produces half resolution 3D images because half the pixels on the LCD are seen by the left eye and half by the right eye. This may be acceptable for graphics, but it makes full resolution text, as displayed by common software, nearly unreadable. Very fine alignment tolerances normally preclude the possibility of removing and replacing the lens in order to switch between 2D and 3D applications. Lenticular lens based displays are therefore limited to use as dedicated 3D devices. DTI has devised a technique which removes this limitation, allowing switching between full resolution 2D and half resolution 3D imaging modes. A second element, in the form of a concave lenticular lens array whose shape is exactly the negative of the first lens, is mounted on a hinge so that it can be swung down over the first lens array. When so positioned the two lenses cancel optically, allowing the user to see full resolution 2D for text or numerical applications. The two lenses, having complementary shapes, naturally tend to nestle together and snap into perfect alignment when pressed together--thus obviating any need for user operated alignment mechanisms. This system represents an ideal solution for laptop and notebook computer applications. It was devised to meet the stringent requirements of a laptop computer manufacturer including very compact size, very low cost, little impact on existing manufacturing or assembly procedures, and compatibility with existing full resolution 2D text- oriented software as well as 3D graphics. Similar requirements apply to high and electronic calculators, several models of which now use LCDs for the display of graphics.
Kobayashi, Satoru; Fujimoto, Shinji; Fukuda, Sumio; Hattori, Ayako; Iwaki, Toshimitsu; Koyama, Norihisa; Tanaka, Taihei; Kokubo, Minoru; Okanishi, Tohru; Togari, Hajime
2006-12-01
The incidence of late-onset circulatory dysfunction (LCD) of premature infants, which is characterized by sudden hypotension and oliguria, has recently increased in Japan. This condition suddenly occurs after several days of age without obvious causes in preterm infants with stable respiration and circulation. Intravenous steroids frequently improve the hypotension. The main problem with LCD is the subsequent and frequent onset of periventricular leukomalacia (PVL), and neurological development appears to be worse in PVL patients with LCD than those without LCD. The aim of this study was to determine whether the severity of magnetic resonance imaging (MRI) findings and neurological outcomes differ between infants who developed PVL after LCD and those who developed PVL without LCD. We retrospectively studied preterm infants who were delivered at less than 33 weeks of gestation between the years 2000 and 2003. During the study period, 10 and 26 infants developed PVL with and without LCD, respectively. The incidence of severe or moderate MRI findings was significantly higher in PVL patients with LCD (100%) than those without LCD (50%; p < 0.05). The incidence of severe cerebral palsy was 88% in PVL infants with LCD and 43% in PVL infants without LCD (p < 0.05). Moreover, the incidence of visual disorders was significantly higher in PVL infants with LCD (63%) than those without LCD (9%; p < 0.01). In conclusion, neurological outcomes are worse in preterm infants who develop PVL with LCD than those without LCD, which is well correlated to the severity judged by MRI findings.
Potential water saving through changes in European diets.
Vanham, D; Hoekstra, A Y; Bidoglio, G
2013-11-01
This study quantifies the water footprint of consumption (WFcons) regarding agricultural products for three diets - the current diet (REF), a healthy diet (HEALTHY) and a vegetarian diet (VEG) - for the four EU zones WEST, NORTH, SOUTH and EAST. The WFcons related to the consumption of agricultural products (4265l per capita per day or lcd) accounts for 89% of the EU's total WFcons (4815lcd). The effect of diet has therefore an essential impact on the total WFcons. The current zonal WFcons regarding agricultural products is: 5875lcd (SOUTH), 4053lcd (EAST), 3761lcd (WEST) and 3197lcd (NORTH). These differences are the result of different consumption behaviours as well as different agricultural production methods and conditions. From the perspective of a healthy diet based on regional dietary guidelines, the intake of several product groups (sugar, crop oils, animal fats and meat) should be decreased and increased for others (vegetables, fruit). The WFcons regarding agricultural products for the alternative diets are the following: HEALTHY 4110lcd (-30%) and VEG 3476lcd (-41%) for SOUTH; HEALTHY 3606lcd (-11%) and VEG 2956lcd (-27%) for EAST; HEALTHY 2766lcd (-26%) and VEG 2208lcd (-41%) for WEST; HEALTHY 3091lcd (-3%) and VEG 2166lcd (-32%) for NORTH. Both the healthy and vegetarian diets thus result - consistent for all zones - in substantial WFcons reductions. The largest reduction takes place for the vegetarian diet. Indeed, a lot of water can be saved by EU citizens by a change in their diet. © 2013.
Design of a Functional Training Prototype for Neonatal Resuscitation
Rajaraman, Sivaramakrishnan; Ganesan, Sona; Jayapal, Kavitha; Kannan, Sadhani
2014-01-01
Birth Asphyxia is considered to be one of the leading causes of neonatal mortality around the world. Asphyxiated neonates require skilled resuscitation to survive the neonatal period. The project aims to train health professionals in a basic newborn care using a prototype with an ultimate objective to have one person at every delivery trained in neonatal resuscitation. This prototype will be a user-friendly device with which one can get trained in performing neonatal resuscitation in resource-limited settings. The prototype consists of a Force Sensing Resistor (FSR) that measures the pressure applied and is interfaced with Arduino® which controls the Liquid Crystal Display (LCD) and Light Emitting Diode (LED) indication for pressure and compression counts. With the increase in population and absence of proper medical care, the need for neonatal resuscitation program is not well addressed. The proposed work aims at offering a promising solution for training health care individuals on resuscitating newborn babies under low resource settings. PMID:27417489
NASA Astrophysics Data System (ADS)
Holter, Borre; Kamfjord, Thor G.; Fossum, Richard; Fagerberg, Ragnar
2000-08-01
The Norwegian based company PolyDisplayR ASA, in collaboration with the Norwegian Army Material Command and SINTEF, has refined, developed and shown with color and black/white technology demonstrators an electrically addressed Smectic A reflective LCD technology featuring: (1) Good contrast, all-round viewing angle and readability under all light conditions (no wash-out in direct sunlight). (2) Infinite memory -- image remains without power -- very low power consumption, no or very low radiation ('silent display') and narrow band updating. (3) Clear, sharp and flicker-free images. (4) Large number of gray tones and colors possible. (5) Simple construction and production -- reduced cost, higher yield, more robust and environmentally friendly. (6) Possibility for lighter, more robust and flexible displays based on plastic substrates. The results and future implementation possibilities for cockpit and soldier-system displays are discussed.
NASA Astrophysics Data System (ADS)
Dunn, William; Garrett, Kimberly S.
2001-09-01
American panel corporation (APC) believes the use of custom designed (instead of ruggedized commercial) AMLCD cells is the only way to meet the specific environmental and performance requirements of the military/commercial avionic, shipboard and rugged ground vehicle markets. The APC/LG.Philips LCD (LG) custom approach mitigates risk to the end-user in many ways. As a part of the APC/LG long- term agreement LG has committed to provide module level equivalent (form, fit and function equivalent) panels for a period of ten years. No other commercial glass manufacturer has provided such an agreement. With the use of LG's commercial production manufacturing capabilities, APC/LG can provide the opportunity to procure a lifetime buy for any program with delivery of the entire lot within six months of order placement. This ensures that the entire production program will receive identical glass for every unit. The APC/LG relationship works where others have failed due to the number of years spent cultivating the mutual trust and respect necessary for establishing such a partnership, LG's interest in capturing the market share of this niche application, and the magnitude of the initial up-front investment by APC in engineering, tooling, facilities, production equipment, and LCD cell inventory.
Wang, Her-Yung; Chen, Jyun-Sheng
2010-01-01
In this study, controlled low-strength concrete (CLSC) is mixed using different water-to-binder (W/B) ratios (1.1, 1.3 and 1.5) and various percentages of sand substituted by waste LCD glass sand (0%, 10%, 20% and 30%). The properties of the fresh concrete, including compressive strength, electrical resistivity, ultrasonic pulse velocity, permeability ratio and shrinking of the CLSC, are examined. Results show that increases in amount of waste glass added result in better slump and slump flow, longer initial setting time and smaller unit weight. Compressive strength decreases with increasing W/B ratio and greater amounts of waste glass added. Both electrical resistivity and ultrasonic pulse velocity increase with increases in amount of waste glass and decreases in W/B ratio. On the contrary, the permeability ratio increases with increases in W/B ratio, but decreases with greater amounts of waste glass added. CLSC specimens cured for different durations show little changes in length with shrinkage below 0.025%. Our findings reveal that CLSC mixed using waste LCD glass in place of sand can meet design requirements. Recycling of waste LCD glass not only offers an economical substitute for aggregates, but also an ecological alternative for waste management. 2009 Elsevier Ltd. All rights reserved.
Liquid-crystal projection image depixelization by spatial phase scrambling
NASA Astrophysics Data System (ADS)
Yang, Xiangyang; Jutamulia, Suganda; Li, Nan
1996-08-01
A technique that removes the pixel structure by scrambling the relative phases among multiple spatial spectra is described. Because of the pixel structure of the liquid-crystal-display (LCD) panel, multiple spectra are generated at the Fourier-spectrum plane (usually at the back focal plane of the imaging lens). A transparent phase mask is placed at the Fourier-spectrum plane such that each spectral order is modulated by one of the subareas of the phase mask, and the phase delay resulting from each pair of subareas is longer than the coherent length of the light source, which is approximately 1 m for the wideband white light sources used in most of LCD s. Such a phase-scrambling technique eliminates the coherence between different spectral orders; therefore, the reconstructed images from the multiple spectra will superimpose incoherently, and the pixel structure will not be observed in the projection image.
A study of optical design of power-saving backlight module with external illuminance
NASA Astrophysics Data System (ADS)
Fang, Yi-Chin; Tzeng, Yih-Fong
2014-05-01
In backlight modules, the light guide plate (LGP) is a key component for performance and also facilitates access to develop LGPs on its own. In this research, we propose a newly developed method: LEDs with freeform as a lighting source, are employed to integrate and manipulate the specially designed and optimized 3D-like pattern distribution of the micro features in order to obtain the required optical characteristics at maximal performance. In this research propose the concept of Light Guide Film(LGF) at the back side of Back Light Unit(BLU). This new design may induce the exterior light ,then improve the power-saving of existent BLU. Two design models are reseated: One is design for 14 inch LCD monitor of notebook computer, which might improve 21% compared to traditional one. Another is designed for 3.5 inch LCD for mobile phone display ,which might improve 15% compared to traditional one.
Fringe field switching AMLCD technology in military and consumer applications
NASA Astrophysics Data System (ADS)
Niemczyk, James
2006-05-01
American Panel Corporation (APC) designs and delivers customized AMLCD products for aircraft cockpits and rugged ground vehicles. APC specifies AMLCD's to be designed and manufactured, based on an exclusive relationship, with both LG.Philips LCD, in South Korea and BOE Hydis, in South Korea. This paper addresses the Fringe Field Switching (FFS) technology developed by BOE Hydis and APC's customization of this technology into both high end avionics display products as well as consumer display products. FFS technology optimizes all optical and electrical performance qualities into a single product. APC offers the high temperature FFS products for all applications.
Ohyanagi, Toshio; Sengoku, Yasuhito
2010-02-01
This article presents a new solution for measuring accurate reaction time (SMART) to visual stimuli. The SMART is a USB device realized with a Cypress Programmable System-on-Chip (PSoC) mixed-signal array programmable microcontroller. A brief overview of the hardware and firmware of the PSoC is provided, together with the results of three experiments. In Experiment 1, we investigated the timing accuracy of the SMART in measuring reaction time (RT) under different conditions of operating systems (OSs; Windows XP or Vista) and monitor displays (a CRT or an LCD). The results indicated that the timing error in measuring RT by the SMART was less than 2 msec, on average, under all combinations of OS and display and that the SMART was tolerant to jitter and noise. In Experiment 2, we tested the SMART with 8 participants. The results indicated that there was no significant difference among RTs obtained with the SMART under the different conditions of OS and display. In Experiment 3, we used Microsoft (MS) PowerPoint to present visual stimuli on the display. We found no significant difference in RTs obtained using MS DirectX technology versus using the PowerPoint file with the SMART. We are certain that the SMART is a simple and practical solution for measuring RTs accurately. Although there are some restrictions in using the SMART with RT paradigms, the SMART is capable of providing both researchers and health professionals working in clinical settings with new ways of using RT paradigms in their work.
iPads in Breast Imaging – A Phantom Study
Hammon, M.; Schlechtweg, P. M.; Schulz-Wendtland, R.; Uder, M.; Schwab, S. A.
2014-01-01
Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as “uncertain”, correct 2 : 1 decisions were classified as “uncertain/readable”. In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of “uncertain” fields did not show significant differences. The number of “uncertain” fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of “uncertain/readable” fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens. PMID:24741126
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false LCD review. 426.425 Section 426.425 Public Health... PROGRAM REVIEW OF NATIONAL COVERAGE DETERMINATIONS AND LOCAL COVERAGE DETERMINATIONS Review of an LCD § 426.425 LCD review. (a) Opportunity for the aggrieved party, after his or her review of the LCD record...
42 CFR 426.418 - LCD record furnished to aggrieved party.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false LCD record furnished to aggrieved party. 426.418... COVERAGE DETERMINATIONS Review of an LCD § 426.418 LCD record furnished to aggrieved party. (a) Elements of a contractor's LCD record furnished to the aggrieved party. Except as provided in paragraph (b) of...
42 CFR 426.418 - LCD record furnished to aggrieved party.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false LCD record furnished to aggrieved party. 426.418... COVERAGE DETERMINATIONS Review of an LCD § 426.418 LCD record furnished to aggrieved party. (a) Elements of a contractor's LCD record furnished to the aggrieved party. Except as provided in paragraph (b) of...
42 CFR 426.418 - LCD record furnished to aggrieved party.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false LCD record furnished to aggrieved party. 426.418... COVERAGE DETERMINATIONS Review of an LCD § 426.418 LCD record furnished to aggrieved party. (a) Elements of a contractor's LCD record furnished to the aggrieved party. Except as provided in paragraph (b) of...
Industrial femtosecond lasers for machining of heat-sensitive polymers (Conference Presentation)
NASA Astrophysics Data System (ADS)
Hendricks, Frank; Bernard, Benjamin; Matylitsky, Victor V.
2017-03-01
Heat-sensitive materials, such as polymers, are used increasingly in various industrial sectors such as medical device manufacturing and organic electronics. Medical applications include implantable devices like stents, catheters and wires, which need to be structured and cut with minimum heat damage. Also the flat panel display market moves from LCD displays to organic LED (OLED) solutions, which utilize heat-sensitive polymer substrates. In both areas, the substrates often consist of multilayer stacks with different types of materials, such as metals, dielectric layers and polymers with different physical characteristic. The different thermal behavior and laser absorption properties of the materials used makes these stacks difficult to machine using conventional laser sources. Femtosecond lasers are an enabling technology for micromachining of these materials since it is possible to machine ultrafine structures with minimum thermal impact and very precise control over material removed. An industrial femtosecond Spirit HE laser system from Spectra-Physics with pulse duration <400 fs, pulse energies of >120 μJ and average output powers of >16 W is an ideal tool for industrial micromachining of a wide range of materials with highest quality and efficiency. The laser offers process flexibility with programmable pulse energy, repetition rate, and pulse width. In this paper, we provide an overview of machining heat-sensitive materials using Spirit HE laser. In particular, we show how the laser parameters (e.g. laser wavelength, pulse duration, applied energy and repetition rate) and the processing strategy (gas assisted single pass cut vs. multi-scan process) influence the efficiency and quality of laser processing.
NASA Astrophysics Data System (ADS)
Passmore, P.; Zimakov, L.; Rozhkov, M.
The 3rd Generation Seismic Recorder, Model 130-01, has been designed to be easier to use - more compact, lighter in weight, lower power, and requires less maintenance than other recorders. Not only is the hardware optimized for field deployments, soft- ware tools as well have been specially developed to support both field and base station operation. The 130's case is a clamshell design, inherently waterproof, with easy access to all user features on the top of the unit. The 130 has 6 input/output connectors, an LCD display, and a removable lid on top of the case. There are two Channel input connectors on a 6-channel unit (only one on a 3-channel unit), a Terminal connector for setup and control, a Net connector combining Ethernet and Serial PPP for network access, a 12 VDC Power connector, and a GPS receiver connector. The LCD display allows the user to monitor the status of various sub systems within the 130 without having a terminal device attached. For storing large amounts of data the IBM MicrodriveTM is offered. User setup, control and status monitoring is done either with a Personal Digital Assistant (PDA) (Palm OS compatible) using our Palm Field Controller (PFC) software or from a PC/workstation using our REF TEK Network Controller (RNC) GUI interface. StarBand VSAT is the premier two-way, always-on, high-speed satellite Internet ser- vice. StarBand means high-speed Internet without the constraints and congestion of land-based cable or telephone networks. StarBand uses a single satellite dish antenna for receiving and for sending dataUno telephone connection is needed. The hardware ° cost is much less than standard VSAT equipment with double or single hop transmis- sion. REF TEK protocol (RTP) provides end-to-end error-correcting data transmission and command/control. StarBandSs low cost VSAT provides two-way, always-on, high speed satellite Internet data availability. REF TEK and StarBand create the most ad- vanced real-time seismological data acquisition system. 1 Results of data transmission and availability is discussed. 2
Kim, Changsun; Cha, Hyunmin; Kang, Bo Seung; Choi, Hyuk Joong; Lim, Tae Ho; Oh, Jaehoon
2016-06-01
Our aim was to prove the feasibility of the remote interpretation of real-time transmitted ultrasound videos of dynamic and static organs using a smartphone with control of the image quality given a limited internet connection speed. For this study, 100 cases of echocardiography videos (dynamic organ)-50 with an ejection fraction (EF) of ≥50 s and 50 with EF <50 %-and 100 cases of suspected pediatric appendicitis (static organ)-50 with signs of acute appendicitis and 50 with no findings of appendicitis-were consecutively selected. Twelve reviewers reviewed the original videos using the liquid crystal display (LCD) monitor of an ultrasound machine and using a smartphone, to which the images were transmitted from the ultrasound machine. The resolution of the transmitted echocardiography videos was reduced by approximately 20 % to increase the frame rate of transmission given the limited internet speed. The differences in diagnostic performance between the two devices when evaluating left ventricular (LV) systolic function by measuring the EF and when evaluating the presence of acute appendicitis were investigated using a five-point Likert scale. The average areas under the receiver operating characteristic curves for each reviewer's interpretations using the LCD monitor and smartphone were respectively 0.968 (0.949-0.986) and 0.963 (0.945-0.982) (P = 0.548) for echocardiography and 0.972 (0.954-0.989) and 0.966 (0.947-0.984) (P = 0.175) for abdominal ultrasonography. We confirmed the feasibility of remotely interpreting ultrasound images using smartphones, specifically for evaluating LV function and diagnosing pediatric acute appendicitis; the images were transferred from the ultrasound machine using image quality-controlled telesonography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rocchetti, Laura; Amato, Alessia; Fonti, Viviana
Graphical abstract: Display Omitted - Highlights: • End-of-life LCD panels represent a source of indium. • Several experimental conditions for indium leaching have been assessed. • Indium is completely extracted with 2 M sulfuric acid at 80 °C for 10 min. • Cross-current leaching improves indium extraction and operating costs are lowered. • Benefits to the environment come from reduction of CO{sub 2} emissions and reagents use. - Abstract: Indium is a critical element mainly produced as a by-product of zinc mining, and it is largely used in the production process of liquid crystal display (LCD) panels. End-of-life LCDs representmore » a possible source of indium in the field of urban mining. In the present paper, we apply, for the first time, cross-current leaching to mobilize indium from end-of-life LCD panels. We carried out a series of treatments to leach indium. The best leaching conditions for indium were 2 M sulfuric acid at 80 °C for 10 min, which allowed us to completely mobilize indium. Taking into account the low content of indium in end-of-life LCDs, of about 100 ppm, a single step of leaching is not cost-effective. We tested 6 steps of cross-current leaching: in the first step indium leaching was complete, whereas in the second step it was in the range of 85–90%, and with 6 steps it was about 50–55%. Indium concentration in the leachate was about 35 mg/L after the first step of leaching, almost 2-fold at the second step and about 3-fold at the fifth step. Then, we hypothesized to scale up the process of cross-current leaching up to 10 steps, followed by cementation with zinc to recover indium. In this simulation, the process of indium recovery was advantageous from an economic and environmental point of view. Indeed, cross-current leaching allowed to concentrate indium, save reagents, and reduce the emission of CO{sub 2} (with 10 steps we assessed that the emission of about 90 kg CO{sub 2}-Eq. could be avoided) thanks to the recovery of indium. This new strategy represents a useful approach for secondary production of indium from waste LCD panels.« less
42 CFR 426.415 - CMS' role in the LCD review.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 3 2010-10-01 2010-10-01 false CMS' role in the LCD review. 426.415 Section 426... Review of an LCD § 426.415 CMS' role in the LCD review. CMS may provide to the ALJ, and all parties to the LCD review, information identifying the person who represents the contractor or CMS, if necessary...
Lee, Joo-Hyung; Lee, Hong-Seok; Lee, Byung-Kee; Choi, Won-Seok; Choi, Hwan-Young; Yoon, Jun-Bo
2007-09-15
A simple liquid crystal display (LCD) backlight unit (BLU) comprising only a single-sheet polydimethylsiloxane (PDMS) light-guide plate (LGP) has been developed. The PDMS LGP, having micropatterns with an inverse-trapezoidal cross section, was fabricated by backside 3-D diffuser lithography followed by PDMS-to-PDMS replication. The fabricated BLU showed an average luminance of 2878 cd/m(2) with 73.3% uniformity when mounted in a 5.08 cm backlight module with four side view 0.85cd LEDs. The developed BLU can greatly reduce the cost and thickness of LCDs, and it can be applied to flexible displays as a flexible light source due to the flexible characteristic of the PDMS itself.
Analysis and design of stereoscopic display in stereo television endoscope system
NASA Astrophysics Data System (ADS)
Feng, Dawei
2008-12-01
Many 3D displays have been proposed for medical use. When we design and evaluate new system, there are three demands from surgeons. Priority is the precision. Secondly, displayed images should be easy to understand, In addition, surgery lasts hours and hours, they do not like fatiguing display. The stereo television endoscope researched in this paper make celiac viscera image on the photosurface of the left and right CCD by imitating human binocular stereo vision effect by using the double-optical lines system. The left and right video signal will be processed by frequency multiplication and display on the monitor, people can observe the stereo image which has depth impression by using a polarized LCD screen and a pair of polarized glasses. Clinical experiments show that by using the stereo TV endoscope people can make minimally invasive surgery more safe and reliable, and can shorten the operation time, and can improve the operation accuracy.
Moiré-reduction method for slanted-lenticular-based quasi-three-dimensional displays
NASA Astrophysics Data System (ADS)
Zhuang, Zhenfeng; Surman, Phil; Zhang, Lei; Rawat, Rahul; Wang, Shizheng; Zheng, Yuanjin; Sun, Xiao Wei
2016-12-01
In this paper we present a method for determining the preferred slanted angle for a lenticular film that minimizes moiré patterns in quasi-three-dimensional (Q3D) displays. We evaluate the preferred slanted angles of the lenticular film for the stripe-type sub-pixel structure liquid crystal display (LCD) panel. Additionally, the sub-pixels mapping algorithm of the specific angle is proposed to assign the images to either the right or left eye channel. A Q3D display prototype is built. Compared with the conventional SLF, this newly implemented Q3D display can not only eliminate moiré patterns but also provide 3D images in both portrait and landscape orientations. It is demonstrated that the developed slanted lenticular film (SLF) provides satisfactory 3D images by employing a compact structure, minimum moiré patterns and stabilized 3D contrast.
NASA Technical Reports Server (NTRS)
1997-01-01
An AGATE Concepts Demonstration was conducted at the Annual National Air Transportation Association (NATA) Convention in 1997. Following, a 5-minute introductory briefing, an interactive simulation of a single-pilot, single-engine aircraft was conducted. The participant was able to take off, fly a brief enroute segment, fly a Global Positioning System (GPS) approach and landing, and repeat the approach and landing segment. The participant was provided an advanced 'highway-in-the-sky' presentation on both a simulated head-up display and on a large LCD head-down display to follow throughout the flight. A single-lever power control and display concept was also provided for control of the engine throughout the flight. A second head-down, multifunction display in the instrument panel provided a moving map display for navigation purposes and monitoring of the status of the aircraft's systems.
Using the Human Eye to Characterize Displays
NASA Technical Reports Server (NTRS)
Gille, Jennifer; Larimer, James
2001-01-01
Monitor characterization has taken on new importance for non-professional users, who are not usually equipped to make photometric measurements. Our purpose was to examine some of the visual judgments used in characterization schemes that have been proposed for web users. We studied adjusting brightness to set the black level, banding effects due to digitization, and gamma estimation in the light and in the dark, and a color-matching task in the light, on a desktop CRT and a laptop LCD. Observers demonstrated the sensitivity of the visual system for comparative judgments in black-level adjustment, banding visibility, and gamma estimation. The results of the color-matching task were ambiguous. In the brightness adjustment task, the action of the adjustment was not as presumed; however, perceptual judgments were as expected under the actual conditions. When the gamma estimates of observers were compared to photometric measurements, problems with the definition of gamma were identified. Information about absolute light levels that would be important for characterizing a display, given the shortcomings of gamma in measuring apparent contrast, are not measurable by eye alone. The LCD was not studied as extensively as the CRT because of viewing-angle problems, and its transfer function did not follow a power law, rendering gamma estimation meaningless.
Chen, Wenxi; Kitazawa, Masumi; Togawa, Tatsuo
2009-09-01
This paper proposes a method to estimate a woman's menstrual cycle based on the hidden Markov model (HMM). A tiny device was developed that attaches around the abdominal region to measure cutaneous temperature at 10-min intervals during sleep. The measured temperature data were encoded as a two-dimensional image (QR code, i.e., quick response code) and displayed in the LCD window of the device. A mobile phone captured the QR code image, decoded the information and transmitted the data to a database server. The collected data were analyzed by three steps to estimate the biphasic temperature property in a menstrual cycle. The key step was an HMM-based step between preprocessing and postprocessing. A discrete Markov model, with two hidden phases, was assumed to represent higher- and lower-temperature phases during a menstrual cycle. The proposed method was verified by the data collected from 30 female participants, aged from 14 to 46, over six consecutive months. By comparing the estimated results with individual records from the participants, 71.6% of 190 menstrual cycles were correctly estimated. The sensitivity and positive predictability were 91.8 and 96.6%, respectively. This objective evaluation provides a promising approach for managing premenstrual syndrome and birth control.
Reading and Studying on the Screen: An Overview of Literature towards Good Learning Design Practice
ERIC Educational Resources Information Center
Nichols, Mark
2016-01-01
As distance education moves increasingly towards online provision, and because of the benefits provided by online approaches, students will be expected to engage with more resources available on screen. Contemporary forms of reading from the screen include reading from tablet devices, LCD monitors, and smartphones. However, print remains the…
CAVE2: a hybrid reality environment for immersive simulation and information analysis
NASA Astrophysics Data System (ADS)
Febretti, Alessandro; Nishimoto, Arthur; Thigpen, Terrance; Talandis, Jonas; Long, Lance; Pirtle, J. D.; Peterka, Tom; Verlo, Alan; Brown, Maxine; Plepys, Dana; Sandin, Dan; Renambot, Luc; Johnson, Andrew; Leigh, Jason
2013-03-01
Hybrid Reality Environments represent a new kind of visualization spaces that blur the line between virtual environments and high resolution tiled display walls. This paper outlines the design and implementation of the CAVE2TM Hybrid Reality Environment. CAVE2 is the world's first near-seamless flat-panel-based, surround-screen immersive system. Unique to CAVE2 is that it will enable users to simultaneously view both 2D and 3D information, providing more flexibility for mixed media applications. CAVE2 is a cylindrical system of 24 feet in diameter and 8 feet tall, and consists of 72 near-seamless, off-axisoptimized passive stereo LCD panels, creating an approximately 320 degree panoramic environment for displaying information at 37 Megapixels (in stereoscopic 3D) or 74 Megapixels in 2D and at a horizontal visual acuity of 20/20. Custom LCD panels with shifted polarizers were built so the images in the top and bottom rows of LCDs are optimized for vertical off-center viewing- allowing viewers to come closer to the displays while minimizing ghosting. CAVE2 is designed to support multiple operating modes. In the Fully Immersive mode, the entire room can be dedicated to one virtual simulation. In 2D model, the room can operate like a traditional tiled display wall enabling users to work with large numbers of documents at the same time. In the Hybrid mode, a mixture of both 2D and 3D applications can be simultaneously supported. The ability to treat immersive work spaces in this Hybrid way has never been achieved before, and leverages the special abilities of CAVE2 to enable researchers to seamlessly interact with large collections of 2D and 3D data. To realize this hybrid ability, we merged the Scalable Adaptive Graphics Environment (SAGE) - a system for supporting 2D tiled displays, with Omegalib - a virtual reality middleware supporting OpenGL, OpenSceneGraph and Vtk applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenney, S; Bevins, N; Flynn, M
2015-06-15
Purpose: The calibration of monitors in radiology is critical to ensure a standardized reading environment. If left unchecked, monitors initially calibrated to follow the DICOM Grayscale Standard Display Function (GSDF) can fall out of calibration. This work presents a quantitative evaluation of the stability of a cohort of monitors with similar deployment times and clinical utilization. Methods: Fifty-four liquid crystal display (LCD) monitors (NEC L200ME) were deployed for clinical use in 2009. At that time, a subset of eight of these monitors were used to generate a look-up table (LUT) using the open-source software pacsDisplay. The software was used tomore » load the LUT to the graphics card of the computer in order to make the monitors compliant with the GSDF. The luminance response of the monitors was evaluated twice over six years, once in 2011 and again in 2015. Results: As expected, the maximum luminance of the monitors decreased over time, with an average reduction from 2009 of 35% in 2011, and 53% in 2015. The luminance ratio (maximum luminance divided by the minimum) also decreased, with the all of the decrease occurring in the first two years (average 20%). There was an overall increase in relative error compared with the DICOM GSDF from measurement to measurement, indicating that deviation from the GSDF increases with monitor luminance reduction. Along with changes in luminance, several other issues were identified during the testing, including non-uniformities, bad pixels, and missing calibration software. Conclusion: From the initial installation of these monitors, most of the degradation occurred during the first two years, highlighting the importance of routine clinical testing of displays. Following such quality assurance, displays could be either re-calibrated or replaced depending on different thresholds. In addition, other issues not related to luminance could be identified and corrected.« less
Fischmeister, Florian Ph.S.; Leodolter, Ulrich; Windischberger, Christian; Kasess, Christian H.; Schöpf, Veronika; Moser, Ewald; Bauer, Herbert
2010-01-01
Throughout recent years there has been an increasing interest in studying unconscious visual processes. Such conditions of unawareness are typically achieved by either a sufficient reduction of the stimulus presentation time or visual masking. However, there are growing concerns about the reliability of the presentation devices used. As all these devices show great variability in presentation parameters, the processing of visual stimuli becomes dependent on the display-device, e.g. minimal changes in the physical stimulus properties may have an enormous impact on stimulus processing by the sensory system and on the actual experience of the stimulus. Here we present a custom-built three-way LC-shutter-tachistoscope which allows experimental setups with both, precise and reliable stimulus delivery, and millisecond resolution. This tachistoscope consists of three LCD-projectors equipped with zoom lenses to enable stimulus presentation via a built-in mirror-system onto a back projection screen from an adjacent room. Two high-speed liquid crystal shutters are mounted serially in front of each projector to control the stimulus duration. To verify the intended properties empirically, different sequences of presentation times were performed while changes in optical power were measured using a photoreceiver. The obtained results demonstrate that interfering variabilities in stimulus parameters and stimulus rendering are markedly reduced. Together with the possibility to collect external signals and to send trigger-signals to other devices, this tachistoscope represents a highly flexible and easy to set up research tool not only for the study of unconscious processing in the brain but for vision research in general. PMID:20122963
2004-08-01
on a pair of high -resolution, LCD medical monitors. The change to the new workstation has required us to rewrite the software... In the original CRT-based system, the two 7 images forming a stereo pair were displayed alternately on the same CRT face, at a high frame rate (120 Hz...then, separately, receive the stereo screening exam on the research GE digital mammography unit.
NASA Astrophysics Data System (ADS)
Lapointe, Jerome
The eye is a vital organ not only in terms of vision and as an important element of facial expression, but also as the first point of contact between people. The loss of an eye has a far-reaching impact on an individual's psyche. Additionally, it affects the patient's professional and social life. Cosmetic rehabilitation with custom made ocular prostheses gives such individuals social and professional acceptance and mitigates problems of re-integration in society. For centuries, ocularists and eye surgeons have worked together to try to create an eye as close to a realistic one possible. All efforts and investments to improve the appearance of ocular prostheses are neutralized by the immobility of the pupil. The objective of this MSc project was to develop a system varying the pupil diameter of ocular prostheses according to the ambient light conditions. The thesis, thus presents the main achievements related to this project. Several researchers have proposed ideas to solve this problem, for example, with the use of liquid crystals, sources of light, LED display, photochromics, magnetic and polarized materials. However, none of these inventions has shown real success. The three main causes for failure include limited space available for integration, the rugged conditions of the ocular prosthesis manufacturing process and the need for a device to be self-powered and autonomous. During this Master's project, several technologies were studied to eventually converge to the liquid crystal display (LCD) solution. Several parameters were tested to successfully demonstrate the first LCD, to our knowledge, surviving the rugged conditions of the ocular prosthesis manufacturing steps. The operating principle of the device developed is very simple. An LC cell is placed in front of the iris image with a pupil of minimum size. This pupil is in fact a series of solar cells. The LC cell contains concentric ring-shaped pixels, which stop the light around the pupil to sequentially alter its diameter. When the ambient light increases, the ring-shaped pixels are activated sequentially to become transparent, the iris is then visible and the pupil appears smaller. A passive and autonomous electronic circuit is also developed in the context of this study. This circuit, which controls the LC cell pixels, is self-powered by nine solar cells interconnected in series. In the final device, the set of solar cells will be integrated into a space equal to the minimum size of the pupil. The design of such a cell is proposed in this paper. The full design of an ocular prosthesis with a dynamic pupil is also proposed and discussed. The number of artificial eyes produced each year is large. A mass produced cheap solution, which would fit the requirements for many patients, would be economically advantageous. The design of such a device is also proposed and discussed in this paper. Several constraints and foreseeable problems in the manufactured prototype are discussed and potential solutions are presented. In addition, a future works to be undertaken to manufacture a working prototype is proposed. Finally, two new approaches to solve the static pupil problem are discussed. The first also uses an LC cell but with an electrode configuration that would avoid the use of an electrical circuit. The second approach is completely different. The device would be based on micromirrors instead of the LC. Some preliminary results are presented. Our team hopes to make a working prototype within three years. Using a clinical trial, Dr. Boulos' team hopes to demonstrate that the dynamic pupil will have a positive impact on the self-worth and quality of life of patients.
42 CFR 426.418 - LCD record furnished to aggrieved party.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 426.418 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... development of the LCD, including, but not limited to, the following: (1) The LCD being challenged. (2) Any... the draft LCD). (4) An index of documents considered that are excluded under paragraph (b) of this...
42 CFR 426.418 - LCD record furnished to aggrieved party.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 426.418 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... development of the LCD, including, but not limited to, the following: (1) The LCD being challenged. (2) Any... the draft LCD). (4) An index of documents considered that are excluded under paragraph (b) of this...
[Extension of cardiac monitoring function by used of ordinary ECG machine].
Chen, Zhencheng; Jiang, Yong; Ni, Lili; Wang, Hongyan
2002-06-01
This paper deals with a portable monitor system on liquid crystal display (LCD) based on this available ordinary ECG machine, which is low power and suitable for China's specific condition. Apart from developing the overall scheme of the system, this paper also has completed the design of the hardware and the software. The 80c196 single chip microcomputer is taken as the central microprocessor and real time electrocardiac single is data treated and analyzed in the system. With the performance of ordinary monitor, this machine also possesses the following functions: five types of arrhythmia analysis, alarm, freeze, and record of automatic pappering, convenient in carrying, with alternate-current (AC) or direct-current (DC) powered. The hardware circuit is simplified and the software structure is optimized in this paper. Multiple low power designs and LCD unit design are adopted and completed in it. Popular in usage, low in cost price, the portable monitor system will have a valuable influence on China's monitor system field.
Fukushima, Toshikazu; Whang, Liang-Ming; Chen, Po-Chun; Putri, Dyah Wulandari; Chang, Ming-Yu; Wu, Yi-Ju; Lee, Ya-Ching
2013-08-01
This study investigated the linkage between performance of two full-scale membrane bioreactor (MBR) systems treating thin-film transistor liquid crystal display (TFT-LCD) wastewater and the population dynamics of dimethylsulfoxide (DMSO)/dimethylsulfide (DMS) degrading bacteria. High DMSO degradation efficiencies were achieved in both MBRs, while the levels of nitrification inhibition due to DMS production from DMSO degradation were different in the two MBRs. The results of real-time PCR targeting on DMSO/DMS degrading populations, including Hyphomicrobium and Thiobacillus spp., indicated that a higher DMSO oxidation efficiency occurred at a higher Hyphomicrobium spp. abundance in the systems, suggesting that Hyphomicrobium spp. may be more important for complete DMSO oxidation to sulfate compared with Thiobacillus spp. Furthermore, Thiobacillus spp. was more abundant during poor nitrification, while Hyphomicrobium spp. was more abundant during good nitrification. It is suggested that microbial population of DMSO/DMS degrading bacteria is closely linking to both DMSO/DMS degradation efficiency and nitrification performance. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hack, Erwin; Gundu, Phanindra Narayan; Rastogi, Pramod
2005-05-10
An innovative technique for reducing speckle noise and improving the intensity profile of the speckle correlation fringes is presented. The method is based on reducing the range of the modulation intensity values of the speckle interference pattern. After the fringe pattern is corrected adaptively at each pixel, a simple morphological filtering of the fringes is sufficient to obtain smoothed fringes. The concept is presented both analytically and by simulation by using computer-generated speckle patterns. The experimental verification is performed by using an amplitude-only spatial light modulator (SLM) in a conventional electronic speckle pattern interferometry setup. The optical arrangement for tuning a commercially available LCD array for amplitude-only behavior is described. The method of feedback to the LCD SLM to modulate the intensity of the reference beam in order to reduce the modulation intensity values is explained, and the resulting fringe pattern and increase in the signal-to-noise ratio are discussed.
NASA Astrophysics Data System (ADS)
Gao, Xin; Sang, Xinzhu; Yu, Xunbo; Zhang, Wanlu; Yan, Binbin; Yu, Chongxiu
2018-06-01
The floating 3D display system based on Tessar array and directional diffuser screen is proposed. The directional diffuser screen can smoothen the gap of lens array and make the 3D image's brightness continuous. The optical structure and aberration characteristics of the floating three-dimensional (3D) display system are analyzed. The simulation and experiment are carried out, which show that the 3D image quality becomes more and more deteriorative with the further distance of the image plane and the increasing viewing angle. To suppress the aberrations, the Tessar array is proposed according to the aberration characteristics of the floating 3D display system. A 3840 × 2160 liquid crystal display panel (LCD) with the size of 23.6 inches, a directional diffuser screen and a Tessar array are used to display the final 3D images. The aberrations are reduced and the definition is improved compared with that of the display with a single-lens array. The display depth of more than 20 cm and the viewing angle of more than 45° can be achieved.
Francois, Monique E; Gilbertson, Nicole M; Eichner, Natalie Z M; Heiston, Emily M; Fabris, Chiara; Breton, Marc; Mehaffey, J Hunter; Hassinger, Taryn; Hallowell, Peter T; Malin, Steven K
2018-06-03
Although low-calorie diets (LCD) improve glucose regulation, it is unclear if interval exercise (INT) is additive. We examined the impact of an LCD versus LCD + INT training on ß-cell function in relation to glucose tolerance in obese adults. Twenty-six adults (Age: 46 ± 12 year; BMI 38 ± 6 kg/m²) were randomized to 2-week of LCD (~1200 kcal/day) or energy-matched LCD + INT (60 min/day alternating 3 min at 90 and 50% HRpeak). A 2 h 75 g oral glucose tolerance test (OGTT) was performed. Insulin secretion rates (ISR) were determined by deconvolution modeling to assess glucose-stimulated insulin secretion ([GSIS: ISR/glucose total area under the curve (tAUC)]) and ß-cell function (Disposition Index [DI: GSIS/IR]) relative to skeletal muscle (Matsuda Index), hepatic (HOMA-IR) and adipose (Adipose-IR fasting ) insulin resistance (IR). LCD + INT, but not LCD alone, reduced glucose and total-phase ISR tAUC (Interactions: p = 0.04 and p = 0.05, respectively). Both interventions improved skeletal muscle IR by 16% ( p = 0.04) and skeletal muscle and hepatic DI (Time: p < 0.05). Improved skeletal muscle DI was associated with lower glucose tAUC ( r = -0.57, p < 0.01). Thus, LCD + INT improved glucose tolerance more than LCD in obese adults, and these findings relate to ß-cell function. These data support LCD + INT for preserving pancreatic function for type 2 diabetes prevention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Shuai
Licorice (Glycyrrhiza uralensis Fisch.) possesses significant anti-cancer activities, but the active ingredients and underlying mechanisms have not been revealed. By screening the cytotoxic activities of 122 licorice compounds against SW480 human colorectal adenocarcinoma cells, we found that licoricidin (LCD) inhibited SW480 cell viability with an IC{sub 50} value of 7.2 μM. Further studies indicated that LCD significantly induced G1/S cell cycle arrest and apoptosis in SW480 cells, accompanied by inhibition of cyclins/CDK1 expression and activation of caspase-dependent pro-apoptotic signaling. Meanwhile, LCD promoted autophagy in SW480 cells, and activated AMPK signaling and inhibited Akt/mTOR pathway. Overexpression of a dominant-negative AMPKα2 abolishedmore » LCD-induced inhibition of Akt/mTOR, autophagic and pro-apoptotic signaling pathways, and significantly reversed loss of cell viability, suggesting activation of AMPK is essential for the anti-cancer activity of LCD. In vivo anti-tumor experiments indicated that LCD (20 mg/kg, i.p.) significantly inhibited the growth of SW480 xenografts in nude mice with an inhibitory rate of 43.5%. In addition, we obtained the glycosylated product LCDG by microbial transformation, and found that glycosylation slightly enhanced the in vivo anti-cancer activities of LCD. This study indicates that LCD could inhibit SW480 cells by inducing cycle arrest, apoptosis and autophagy, and is a potential chemopreventive or chemotherapeutic agent against colorectal cancer. - Highlights: • Molecular mechanisms for cytotoxic activity of licoricidin (LCD) were investigated. • LCD promoted autophagy of SW480 cells through AMPK and Akt/mTOR signaling pathways. • Both LCD and its glucoside showed in vivo anti-colorectal cancer activities.« less
NASA Astrophysics Data System (ADS)
Kobayashi, Shunsuke; Mochizuki, Akihiro
The following sections are included: * INTRODUCTION * TUNABLE BIREFRINGENCE LCDs * Nematic Device with Homogeneous Alignment * Nematic Device with Homeotropic Alignment * ELECTRICALLY CONTROLLED BIREFRINGENCE EFFECT LCDs WITH A COMPENSATING CELL OR POLYMER LAYERS * Super Homeotropic LCDs * Black and White STN LCDs * Optical mode interference * Guest-host mode * Double-layered STN * Retardation film compensated STN * DUAL FREQUENCY ADDRESSING LCDs * Application for DSM LCDs * Application for TN LCDs * PI-CELL * CHOLESTERIC-NEMATIC PHASE CHANGE LCDs * Storage Mode LCDs * Stabilized Hysteresis Mode LCDs * THERMALLY ADDRESSED LCDs (CHOLESTERIC) * BISTABLE LCD * WIDE VIEWING ANGLE TN LCDs USING RETARDATION SHEETS * Type 1 Cells * Type 2 Cells * REFERENCES
Leite, Jose O; DeOgburn, Ryan; Ratliff, Joseph; Su, Randy; Smyth, Joan A; Volek, Jeff S; McGrane, Mary M; Dardik, Alan; Fernandez, Maria Luz
2010-04-01
Low-carbohydrate diets (LCD) efficiently induce weight loss and favorably affect plasma lipids, however, the effect of LCD on atherosclerosis is still argued. To evaluate the effect of LCD on the prevention of atherosclerosis. Twenty guinea pigs were fed either a LCD or a low-fat diet (LFD) in combination with high-cholesterol (0.25g/100g) for 12 weeks. The percentage energy of macronutrient distribution was 10:65:25 for carbohydrate:fat:protein for the LCD, and 55:20:25 for the LFD. Plasma lipids were measured using colorimetric assays. Plasma and aortic oxidized (oxLDL) were quantified using ELISA methods. Inflammatory cytokines were measured in aortic homogenates using an immunoassay. H&E stained sections of aortic sinus and Schultz stained sections of carotid arteries were examined. LDL cholesterol was lower in the LCD compared to the LFD group (71.9+/-34.8 vs. 81.7+/-26.9mg/dL; p=0.039). Aortic cholesterol was also lower in the LCD (4.98+/-1.3mg/g) compared to the LFD group (6.68+/-2.0mg/g); p<0.05. The Schultz staining method confirmed less aortic cholesterol accumulation in the LCD group. Plasma oxLDL did not differ between groups, however, aortic oxLDL was 61% lower in the LCD compared to the LFD group (p=0.045). There was a positive correlation (r=0.63, p=0.03) between oxLDL and cholesterol concentration in the aorta of LFD group, which was not observed in LCD group (r=-0.05, p=0.96). Inflammatory markers were reduced in guinea pigs from the LCD group (p<0.05) and they were correlated with the decreases in oxLDL in aorta. These results suggest that LCD not only decreases lipid deposition, but also prevents the accumulation of oxLDL and reduces inflammatory cytokines within the arterial wall and may prevent atherosclerosis. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Taneja, S. R.; Kumar, Jagdish; Thariyan, K. K.; Verma, Sanjeev
2005-01-01
Clinical chemistry analyser is a high-performance microcontroller-based photometric biochemical analyser to measure various blood biochemical parameters such as blood glucose, urea, protein, bilirubin, and so forth, and also to measure and observe enzyme growth occurred while performing the other biochemical tests such as ALT (alkaline amino transferase), amylase, AST (aspartate amino transferase), and so forth. These tests are of great significance in biochemistry and used for diagnostic purposes and classifying various disorders and diseases such as diabetes, liver malfunctioning, renal diseases, and so forth. An inexpensive clinical chemistry analyser developed by the authors is described in this paper. This is an open system in which any reagent kit available in the market can be used. The system is based on the principle of absorbance transmittance photometry. System design is based around 80C31 microcontroller with RAM, EPROM, and peripheral interface devices. The developed system incorporates light source, an optical module, interference filters of various wave lengths, peltier device for maintaining required temperature of the mixture in flow cell, peristaltic pump for sample aspiration, graphic LCD display for displaying blood parameters, patients test results and kinetic test graph, 40 columns mini thermal printer, and also 32-key keyboard for executing various functions. The lab tests conducted on the instrument include versatility of the analyzer, flexibility of the software, and treatment of sample. The prototype was tested and evaluated over 1000 blood samples successfully for seventeen blood parameters. Evaluation was carried out at Government Medical College and Hospital, the Department of Biochemistry. The test results were found to be comparable with other standard instruments. PMID:18924737
Taneja, S R; Gupta, R C; Kumar, Jagdish; Thariyan, K K; Verma, Sanjeev
2005-01-01
Clinical chemistry analyser is a high-performance microcontroller-based photometric biochemical analyser to measure various blood biochemical parameters such as blood glucose, urea, protein, bilirubin, and so forth, and also to measure and observe enzyme growth occurred while performing the other biochemical tests such as ALT (alkaline amino transferase), amylase, AST (aspartate amino transferase), and so forth. These tests are of great significance in biochemistry and used for diagnostic purposes and classifying various disorders and diseases such as diabetes, liver malfunctioning, renal diseases, and so forth. An inexpensive clinical chemistry analyser developed by the authors is described in this paper. This is an open system in which any reagent kit available in the market can be used. The system is based on the principle of absorbance transmittance photometry. System design is based around 80C31 microcontroller with RAM, EPROM, and peripheral interface devices. The developed system incorporates light source, an optical module, interference filters of various wave lengths, peltier device for maintaining required temperature of the mixture in flow cell, peristaltic pump for sample aspiration, graphic LCD display for displaying blood parameters, patients test results and kinetic test graph, 40 columns mini thermal printer, and also 32-key keyboard for executing various functions. The lab tests conducted on the instrument include versatility of the analyzer, flexibility of the software, and treatment of sample. The prototype was tested and evaluated over 1000 blood samples successfully for seventeen blood parameters. Evaluation was carried out at Government Medical College and Hospital, the Department of Biochemistry. The test results were found to be comparable with other standard instruments.
Blue laser diode (LD) and light emitting diode (LED) applications
NASA Astrophysics Data System (ADS)
Bergh, Arpad A.
2004-09-01
The family of blue LEDs, edge emitting and surface emitting lasers, enable a number of applications. Blue lasers are used in digital applications such as optical storage in high density DVDs. The resolution of the spot size and hence the storage density is diffraction limited and is inversely proportional to the square of the wavelength of the laser. Other applications include printing, optical scanners, and high-resolution photo-lithography.As light emitters, blue LEDs are used for signaling and in direct view large area emissive displays. They are also making inroads into signage and LCD back-lighting, mobile platforms, and decorative accent lighting in curtains, furniture, etc.Blue LEDs produce white light either with phosphor wavelength converters or in combination with red and green LEDs. The full potential of LED light sources will require three devices to enable complete control over color and intensity.Sensing and medical/bio applications have a major impact on home security, on monitoring the environment, and on health care. New emerging diagnostic and therapeutic applications will improve the quality and reduce the cost of health care.
Thermal enclosure system functional simulation user's manual
NASA Technical Reports Server (NTRS)
Morris, A. Terry
1994-01-01
A form and function simulation of the thermal enclosure system (TES) for a microgravity protein crystal growth experiment has been developed as part of an investigation of the benefits and limitations of intravehicular telerobotics to aid in microgravity science and production. A user can specify the time, temperature, and sample rate profile for a given experiment, and menu options and status are presented on an LCD display. This report describes the features and operational procedures for the functional simulation.
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Fan, Jiahua; Dallas, William J.; Krupinski, Elizabeth A.; Johnson, Jeffrey
2009-08-01
This presentation describes work in progress that is the result of an NIH SBIR Phase 1 project that addresses the wide- spread concern for the large number of breast-cancers and cancer victims [1,2]. The primary goal of the project is to increase the detection rate of microcalcifications as a result of the decrease of spatial noise of the LCDs used to display the mammograms [3,4]. Noise reduction is to be accomplished with the aid of a high performance CCD camera and subsequent application of local-mean equalization and error diffusion [5,6]. A second goal of the project is the actual detection of breast cancer. Contrary to the approach to mammography, where the mammograms typically have a pixel matrix of approximately 1900 x 2300 pixels, otherwise known as FFDM or Full-Field Digital Mammograms, we will only use sections of mammograms with a pixel matrix of 256 x 256 pixels. This is because at this time, reduction of spatial noise on an LCD can only be done on relatively small areas like 256 x 256 pixels. In addition, judging the efficacy for detection of breast cancer will be done using two methods: One is a conventional ROC study [7], the other is a vision model developed over several years starting at the Sarnoff Research Center and continuing at the Siemens Corporate Research in Princeton NJ [8].
Simulating multiprimary LCDs on standard tri-stimulus LC displays
NASA Astrophysics Data System (ADS)
Lebowsky, Fritz; Vonneilich, Katrin; Bonse, Thomas
2008-01-01
Large-scale, direct view TV screens, in particular those based on liquid crystal technology, are beginning to use subpixel structures with more than three subpixels to implement a multi-primary display with up to six primaries. Since their input color space is likely to remain tri-stimulus RGB we first focus on some fundamental constraints. Among them, we elaborate simplified gamut mapping architectures as well as color filter geometry, transparency, and chromaticity coordinates in color space. Based on a 'display centric' RGB color space tetrahedrization combined with linear interpolation we describe a simulation framework which enables optimization for up to 7 primaries. We evaluated the performance through mapping the multi-primary design back onto a RGB LC display gamut without building a prototype multi-primary display. As long as we kept the RGB equivalent output signal within the display gamut we could analyze all desirable multi-primary configurations with regard to colorimetric variance and visually perceived quality. Not only does our simulation tool enable us to verify a novel concept it also demonstrates how carefully one needs to design a multiprimary display for LCD TV applications.
Measurement of luminance and color uniformity of displays using the large-format scanner
NASA Astrophysics Data System (ADS)
Mazikowski, Adam
2017-08-01
Uniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce satisfactory results, so a different solution is proposed in the paper. The developed system consists of the large-format X-Y-Z ISEL scanner (isel Germany AG), Konica Minolta high sensitivity spot photometer-colorimeter (e.g. CS-200, Konica Minolta, Inc.) and PC computer. Dedicated software in LabView environment for control of the scanner, transfer the measured data to the computer, and visualization of measurement results was also prepared. Based on the developed setup measurements of plasma display and LCD-LED display were performed. A heavily wornout plasma TV unit, with several artifacts visible was selected. These tests show the advantages and drawbacks of described scanning method with comparison with 9-point simplified uniformity determining method.
Development of a replacement AMLCD used on multiple platforms
NASA Astrophysics Data System (ADS)
Walsh, Kevin L.; Gobron, Robert
2002-08-01
A goal of military display users and manufacturers is commonality: to utilize a given display on as many platforms as possible. The often-addressed concern of obsolescence of commercial AMLCDs used on military programs becomes a key issue, though, with regard to commonality. Obsolescence occurs as the tools used in the manufacture of an AMLCD age and as new and improved materials and processes are developed. The LCD manufacturer, at some point, decides to cease the manufacture of a particular AMLCD. The users of that AMLCD then have two choices: make a lifetime buy of LCDs, or find a replacement. For a display which has achieved some degree of commonality, this choice must be faced by a number of different users on a number of platforms. This paper addresses some of the problems encountered when such a choice is made, as an SVGA display made by one manufacturer is replaced by an XGA display made by a different manufacturer.
Statis omnidirectional stereoscopic display system
NASA Astrophysics Data System (ADS)
Barton, George G.; Feldman, Sidney; Beckstead, Jeffrey A.
1999-11-01
A unique three camera stereoscopic omnidirectional viewing system based on the periscopic panoramic camera described in the 11/98 SPIE proceedings (AM13). The 3 panoramic cameras are equilaterally combined so each leg of the triangle approximates the human inter-ocular spacing allowing each panoramic camera to view 240 degree(s) of the panoramic scene, the most counter clockwise 120 degree(s) being the left eye field and the other 120 degree(s) segment being the right eye field. Field definition may be by green/red filtration or time discrimination of the video signal. In the first instance a 2 color spectacle is used in viewing the display or in the 2nd instance LCD goggles are used to differentiate the R/L fields. Radially scanned vidicons or re-mapped CCDs may be used. The display consists of three vertically stacked 120 degree(s) segments of the panoramic field of view with 2 fields/frame. Field A being the left eye display and Field B the right eye display.
Cross-current leaching of indium from end-of-life LCD panels.
Rocchetti, Laura; Amato, Alessia; Fonti, Viviana; Ubaldini, Stefano; De Michelis, Ida; Kopacek, Bernd; Vegliò, Francesco; Beolchini, Francesca
2015-08-01
Indium is a critical element mainly produced as a by-product of zinc mining, and it is largely used in the production process of liquid crystal display (LCD) panels. End-of-life LCDs represent a possible source of indium in the field of urban mining. In the present paper, we apply, for the first time, cross-current leaching to mobilize indium from end-of-life LCD panels. We carried out a series of treatments to leach indium. The best leaching conditions for indium were 2M sulfuric acid at 80°C for 10min, which allowed us to completely mobilize indium. Taking into account the low content of indium in end-of-life LCDs, of about 100ppm, a single step of leaching is not cost-effective. We tested 6 steps of cross-current leaching: in the first step indium leaching was complete, whereas in the second step it was in the range of 85-90%, and with 6 steps it was about 50-55%. Indium concentration in the leachate was about 35mg/L after the first step of leaching, almost 2-fold at the second step and about 3-fold at the fifth step. Then, we hypothesized to scale up the process of cross-current leaching up to 10 steps, followed by cementation with zinc to recover indium. In this simulation, the process of indium recovery was advantageous from an economic and environmental point of view. Indeed, cross-current leaching allowed to concentrate indium, save reagents, and reduce the emission of CO2 (with 10 steps we assessed that the emission of about 90kg CO2-Eq. could be avoided) thanks to the recovery of indium. This new strategy represents a useful approach for secondary production of indium from waste LCD panels. Copyright © 2015 Elsevier Ltd. All rights reserved.
Environmental impact assessment of different end-of-life LCD management strategies.
Amato, Alessia; Rocchetti, Laura; Beolchini, Francesca
2017-01-01
The strong growth of the electrical and electronic equipment production combined with its short lifespan are causing the production of a significant amount of waste to treat. In particular, the present paper focuses on end-of-life liquid crystal displays (LCDs) for their significant content of valuable materials, like plastic, glass and metals that could be recovered after dismantling. In the recent literature, traditional LCD recycling processes are combined with innovative treatments, which allow to recover critical raw materials, such as indium. In this context, we have evaluated the environmental impact of four different strategies of end-of-life LCD management: the disposal in landfilling sites, the incineration, the traditional recycling treatment and an innovative process also addressed to the recovery of indium. The traditional recycling treatment resulted to be the best scenario for the environment. Indeed, a life cycle assessment study gave following environmental burdens (if negative they are credits): 18, 81, -68, -60kg CO 2 -equiv. and 0.08, 0.01, -0.25, -0.18mol H + -equiv., for the four scenarios in the categories of global warming and acidification, respectively. The limit of the variability of LCD composition was overcome including additional literature data in the study. In order to improve the innovative process sustainability, a system of water recirculation was optimized with a consequent impact decrease of 35% in the global warming category. Nevertheless, this action should be combined with an increase of indium concentration in the panel because the low metal content represents the bottleneck of the overall approach. In this regard, a sensitivity analysis showed that an increase of at least five times in indium concentration in the waste is needed to observe an advantage of the innovative vs the traditional recycling process, when the impact category of climate change is considered. As a whole, the life cycle assessment was confirmed as a key tool for the choice of the best option of WEEE management. Copyright © 2016 Elsevier Ltd. All rights reserved.
Detection System of Sound Noise Level (SNL) Based on Condenser Microphone Sensor
NASA Astrophysics Data System (ADS)
Rajagukguk, Juniastel; Eka Sari, Nurdieni
2018-03-01
The research aims to know the noise level by using the Arduino Uno as data processing input from sensors and called as Sound Noise Level (SNL). The working principle of the instrument is as noise detector with the show notifications the noise level on the LCD indicator and in the audiovisual form. Noise detection using the sensor is a condenser microphone and LM 567 as IC op-amps, which are assembled so that it can detect the noise, which sounds are captured by the sensor will turn the tide of sinusoida voice became sine wave energy electricity (altering sinusoida electric current) that is able to responded to complaints by the Arduino Uno. The tool is equipped with a detector consists of a set indicator LED and sound well as the notification from the text on LCD 16*2. Work setting indicators on the condition that, if the measured noise > 75 dB then sound will beep, the red LED will light up indicating the status of the danger. If the measured value on the LCD is higher than 56 dB, sound indicator will be beep and yellow LED will be on indicating noisy. If the noise measured value <55 dB, sound indicator will be quiet indicating peaceful from noisy. From the result of the research can be explained that the SNL is capable to detecting and displaying noise level with a measuring range 50-100 dB and capable to delivering the notification noise in audiovisual.
Chen, Te-San; Huang, Kuo-Lin; Lai, Yu-Chan; Kuo, Yi-Ming
2012-08-15
This investigation studies the electro-regeneration of Ce(IV) from Ce(III) in 4 M HNO(3) in the presence/absence of NH(4)(+) and real spent thin-film transistor liquid-crystal display (TFT-LCD) Cr-etching solutions. On Pt, at 2 A and 70 °C for 100 min, the Ce(IV) yield and apparent rate constant of Ce(III) oxidation in 4 M HNO(3) without NH(4)(+) were 100% and 5.54 × 10(-4) s(-1), respectively (and the activation energy was 13.1 kJ mol(-1)). Cyclic voltammetric and electrolytic measurements consistently support the noticeable inhibition by NH(4)(+) of Ce(III) oxidation and lowering of the Ce(IV) yield, respectively. The apparent diffusion coefficients for 0.2 and 0.02 M Ce(III) oxidation in 4 M HNO(3) that contained 0-0.6 M NH(4)(+) were (0.38-0.25) × 10(-5) and (1.6-0.9) × 10(-5) cm(2) s(-1), respectively. Because of combined effects of NH(4)(+) and anion impurities, the 100 min Ce(IV) yield of a real spent TFT-LCD Cr-etching solution (with [NH(4)(+)]/[Ce(III)] = 0.74 M/0.39 M) was 82%, lower than that of 4 M HNO(3) without NH(4)(+), but higher than those of 4 M HNO(3) that contained anion impurities with/without 0.4 M NH(4)(+). Copyright © 2012 Elsevier Ltd. All rights reserved.
Optimization of visual evoked potential (VEP) recording systems.
Karanjia, Rustum; Brunet, Donald G; ten Hove, Martin W
2009-01-01
To explore the influence of environmental conditions on pattern visual evoked potential (VEP) recordings. Fourteen subjects with no known ocular pathology were recruited for the study. In an attempt to optimize the recording conditions, VEP recordings were performed in both the seated and recumbent positions. Comparisons were made between recordings using either LCD or CRT displays and recordings obtained in silence or with quiet background music. Paired recordings (in which only one variable was changed) were analyzed for changes in P100 latency, RMS noise, and variability. Baseline RMS noise demonstrated a significant decrease in the variability during the first 50msec accompanied by a 73% decrease in recording time for recumbent position when compared to the seated position (p<0.05). Visual evoked potentials recorded using LCD monitors demonstrated a significant increase in the P100 latency when compared to CRT recordings in the same subjects. The addition of background music did not affect the amount of RMS noise during the first 50msec of the recordings. This study demonstrates that the use of the recumbent position increases patient comfort and improves the signal to noise ratio. In contrast, the addition of background music to relax the patient did not improve the recording signal. Furthermore, the study illustrates the importance of avoiding low-contrast visual stimulation patterns obtained with LCD as they lead to higher latencies resulting in false positive recordings. These findings are important when establishing or modifying a pattern VEP recording protocol.
NASA Astrophysics Data System (ADS)
Park, Baek Sung; Hyung, Kyung Hee; Oh, Gwi Jeong; Jung, Hyun Wook
2018-02-01
The color filter (CF) is one of the key components for improving the performance of TV displays such as liquid crystal display (LCD) and white organic light emitting diodes (WOLED). The profile defects like undercut during the fine fabrication processes for CF layers are inevitably generated through the UV exposure and development processes, however, these can be controlled through the baking process. In order to resolve the profile defects of CF layers, in this study, the real-time dynamic changes of CF layers are monitored during the baking process by changing components such as polymeric binder and acrylate. The motion of pigment particles in CF layers during baking is quantitatively interpreted using multi-speckle diffusing wave spectroscopy (MSDWS), in terms of the autocorrelation function and the characteristic time of α-relaxation.
Spectral characteristics of light sources for S-cone stimulation.
Schlegelmilch, F; Nolte, R; Schellhorn, K; Husar, P; Henning, G; Tornow, R P
2002-11-01
Electrophysiological investigations of the short-wavelength sensitive pathway of the human eye require the use of a suitable light source as a S-cone stimulator. Different light sources with their spectral distribution properties were investigated and compared with the ideal S-cone stimulator. First, the theoretical background of the calculation of relative cone energy absorption from the spectral distribution function of the light source is summarized. From the results of the calculation, the photometric properties of the ideal S-cone stimulator will be derived. The calculation procedure was applied to virtual light sources (computer generated spectral distribution functions with different medium wavelengths and spectrum widths) and to real light sources (blue and green light emitting diodes, blue phosphor of CRT-monitor, multimedia projector, LCD monitor and notebook display). The calculated relative cone absorbencies are compared to the conditions of an ideal S-cone stimulator. Monochromatic light sources with wavelengths of less than 456 nm are close to the conditions of an ideal S-cone stimulator. Spectrum widths up to 21 nm do not affect the S-cone activation significantly (S-cone activation change < 0.2%). Blue light emitting diodes with peak wavelength at 448 nm and spectrum bandwidth of 25 nm are very useful for S-cone stimulation (S-cone activation approximately 95%). A suitable display for S-cone stimulation is the Trinitron computer monitor (S-cone activation approximately 87%). The multimedia projector has a S-cone activation up to 91%, but their spectral distribution properties depends on the selected intensity. LCD monitor and notebook displays have a lower S-cone activation (< or = 74%). Carefully selecting the blue light source for S-cone stimulation can reduce the unwanted L-and M-cone activation down to 4% for M-cones and 1.5% for L-cones.
Motivating Non-science Majors: The Technology of Electromagnetic Waves
NASA Astrophysics Data System (ADS)
Henrich, Victor E.
2018-01-01
To address the need for physics courses that stimulate non-STEM majors' interest in, and appreciation of, science, the Department of Applied Physics has developed a popular course for Yale College undergraduates, The Technological World, that explains the physics behind technologies that students use every day. The course provides an in-depth development of electromagnetic waves, applying them to technologies as diverse as LCD displays, GPS, fiber optics, CAT scans, LEDs, and stealth aircraft. It utilizes a conventional lecture format, with many in-class demonstrations.
Psychophysical contrast calibration
To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli
2013-01-01
Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843
Recent advances in small molecule OLED-on-silicon microdisplays
NASA Astrophysics Data System (ADS)
Ghosh, Amalkumar P.; Ali, Tariq A.; Khayrullin, Ilyas; Vazan, Fridrich; Prache, Olivier F.; Wacyk, Ihor
2009-08-01
High resolution OLED-on-silicon microdisplay technology is unique and challenging since it requires very small subpixel dimensions (~ 2-5 microns). eMagin's OLED microdisplay is based on white top emitter architecture using small molecule organic materials. The devices are fabricated using high Tg materials. The devices are hermetically sealed with vacuum deposited thin film layers. LCD-type color filters are patterned using photolithography methods to generate primary R, G, B colors. Results of recent improvements in the OLED-on-silicon microdisplay technology, with emphasis on efficiencies, lifetimes, grey scale and CIE color coordinates for SVGA and SXGA resolution microdisplays is presented.
Johnson, Colleen; Edison, Brenda; Brouda, Irina; Green, Barbara
2009-09-01
Scalp psoriasis is reported to occur in 50-80% of psoriasis sufferers. Treatment of scalp psoriasis requires special consideration of product esthetics and staining potential due to the presence of hair. To evaluate the potential of a new, marketed liquor carbonis distillate (LCD; coal tar) solution to discolor naturally light or color-processed hair under exaggerated exposure conditions. Samples of naturally light and color-processed hair from a single donor were exposed to LCD solution repeatedly over 14 days and via submergence for 24 h. Color of LCD-treated hair samples was compared with untreated control hair samples. LCD solution did not discolor naturally light or color-processed hair following repeated exposures and 24 h submergence. The marketed LCD solution does not appear to discolor naturally light or color-processed hair.
Retrospective study on the efficacy of a low-carbohydrate diet for impaired glucose tolerance
Maekawa, Satoshi; Kawahara, Tetsuya; Nomura, Ryosuke; Murase, Takayuki; Ann, Yasuyoshi; Oeholm, Masayuki; Harada, Masaru
2014-01-01
Background In recent years, the number of people with impaired glucose tolerance (IGT) has increased steadily worldwide. It is clear that the prevention of diabetes is important from the perspective of public health, medical care, and economics. It was recently reported that a low-carbohydrate diet (LCD) is useful for achieving weight loss and glycemic control, but there is no information about the effects of the LCD on IGT. We designed a 7-day in-hospital educational program focused on the LCD for IGT. Methods The subjects were 72 patients with IGT (36 in the LCD group and 36 in the control group) who were enrolled from April 2007–March 2012 and followed for 12 months. We retrospectively compared the LCD group with the control group. Results In 69.4% of the LCD group, blood glucose was normalized at 12 months and the 2-hour plasma glucose level in the oral glucose tolerance test (OGTT) was reduced by 33 mg/dL. In addition, the incidence of diabetes was significantly lower in the LCD group than in the control group at 12 months (0% versus 13.9%, P=0.02). The LCD group showed a significant decrease in fasting plasma glucose, hemoglobin A1c, the homeostasis model of assessment of insulin resistance value, body weight and serum triglycerides (TGs) at 12 months, while there was a significant increase of the serum high-density lipoprotein (HDL) cholesterol level. Conclusion The LCD is effective for normalizing blood glucose and preventing progression to type 2 diabetes in patients with IGT. PMID:24966689
Non-Destructive Inspection by Infrared Imaging Spectroscopy. Phase 1
1994-10-14
light, the AOTF through its birefrengence , the LCD through an entrance polarizer necessary for proper operation. Hence, these devices provide a fixed...through atmosphere of transmission Ta(X), but without any spectral filtering is 20 UNCLASSIFIED I I UNCLASSIFIED P(A) = ~A) , A1 T.(1) T...UNCLASSIFIED dependent on the signal level. Atmospheric transmission is assumed to be from a three meter path at sea-level. Target radiance comprises
Fan, Jian-Gao; Zhong, Lan; Tia, Li-Yan; Xu, Zheng-Jie; Li, Min-Sheng; Wang, Guo-Liang
2005-01-01
AIM: To evaluate the effects of ursodeoxycholic acid (UDCA) and/or low-calorie diet (LCD) on a rat model of nonalcoholic steatohepatitis (NASH). METHODS: Fifty-five Sprague-Dawley rats were divided into five groups. The control group (n = 9) was fed with standard rat diet for 12 wk, NASH group (n = 10) was fed with high-fat diet consisted of normal diet, 10% lard oil and 2% cholesterol for 12 wk, UDCA group (n = 10) was fed with high-fat diet supplemented with UDCA at a dose of 25 mg/(kg·d) in drinking water for 12 wk, LCD group (n = 10) was fed with high-fat diet for 10 wk and then LCD for 2 wk, and UDCA+LCD group (n = 15) was fed with high-fat diet for 10 wk, followed by LCD+UDCA for 2 wk. At the end of the experiment, body weight, serum biochemical index, and hepatopathologic changes were examined. RESULTS: Compared with the control group, rats in the NASH group had significantly increased body weight, liver weight, and serum lipid and aminotransferase levels. All rats in the NASH group developed steatohepatitis, as determined by their liver histology. Compared with the NASH group, there were no significant changes in body weight, liver weight, blood biochemical index, the degree of hepatic steatosis, and histological activity index (HAI) score in the UDCA group; however, body and liver weights were significantly decreased, and the degree of steatosis was markedly improved in rats of both the LCD group and the UDCA+LCD group, but significant improvement with regard to serum lipid variables and hepatic inflammatory changes were seen only in rats of the UDCA+LCD group, and not in the LCD group. CONCLUSION: LCD might play a role in the treatment of obesity and hepatic steatosis in rats, but it exerts no significant effect on both serum lipid disorders and hepatic inflammatory changes. UDCA may enhance the therapeutic effects of LCD on steatohepatitis accompanied by obesity and hyperl-ipidemia. However, UDCA alone is not effective in the prevention of steatohepatitis induced by high-fat diet. PMID:15818751
Automated platform for determination of LEDs spatial radiation pattern
NASA Astrophysics Data System (ADS)
Vladescu, Marian; Vuza, Dan Tudor
2015-02-01
Nowadays technologies lead to remarkable properties of the light-emitting diodes (LEDs), making them attractive for more and more applications, such as: interior and exterior lighting, outdoor LED panels, traffic signals, automotive (tail and brake lights, backlighting in dashboard and switches), backlighting of display panels, LCD displays, symbols on switches, keyboards, graphic boards and measuring scales. Usually, LEDs are small light sources consisting of a chip placed into a package, which may bring additional optics to this encapsulated ensemble, resulting in a less or more complex spatial distribution of the light intensity, with particular radiation patterns. This paper presents an automated platform designed to allow a quick and accurate determination of the spatial radiation patterns of LEDs encapsulated in various packages. Keywords: LED, luminous
A color gamut description algorithm for liquid crystal displays in CIELAB space.
Sun, Bangyong; Liu, Han; Li, Wenli; Zhou, Shisheng
2014-01-01
Because the accuracy of gamut boundary description is significant for gamut mapping process, a gamut boundary calculating method for LCD monitors is proposed in this paper. Within most of the previous gamut boundary calculation algorithms, the gamut boundary is calculated in CIELAB space directly, and part of inside-gamut points are mistaken for the boundary points. While, in the new proposed algorithm, the points on the surface of RGB cube are selected as the boundary points, and then converted and described in CIELAB color space. Thus, in our algorithm, the true gamut boundary points are found and a more accurate gamut boundary is described. In experiment, a Toshiba LCD monitor's 3D CIELAB gamut for evaluation is firstly described which has regular-shaped outer surface, and then two 2D gamut boundaries ( CIE-a*b* boundary and CIE-C*L* boundary) are calculated which are often used in gamut mapping process. When our algorithm is compared with several famous gamut calculating algorithms, the gamut volumes are very close, which indicates that our algorithm's accuracy is precise and acceptable.
A Color Gamut Description Algorithm for Liquid Crystal Displays in CIELAB Space
Sun, Bangyong; Liu, Han; Li, Wenli; Zhou, Shisheng
2014-01-01
Because the accuracy of gamut boundary description is significant for gamut mapping process, a gamut boundary calculating method for LCD monitors is proposed in this paper. Within most of the previous gamut boundary calculation algorithms, the gamut boundary is calculated in CIELAB space directly, and part of inside-gamut points are mistaken for the boundary points. While, in the new proposed algorithm, the points on the surface of RGB cube are selected as the boundary points, and then converted and described in CIELAB color space. Thus, in our algorithm, the true gamut boundary points are found and a more accurate gamut boundary is described. In experiment, a Toshiba LCD monitor's 3D CIELAB gamut for evaluation is firstly described which has regular-shaped outer surface, and then two 2D gamut boundaries ( CIE-a*b* boundary and CIE-C*L* boundary) are calculated which are often used in gamut mapping process. When our algorithm is compared with several famous gamut calculating algorithms, the gamut volumes are very close, which indicates that our algorithm's accuracy is precise and acceptable. PMID:24892068
NASA Astrophysics Data System (ADS)
Claussen, U.
1984-01-01
The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.
A superior architecture of brightness enhancement for display backlighting
NASA Astrophysics Data System (ADS)
Dross, Oliver; Parkyn, William A.; Chaves, Julio; Falicoff, Waqidi; Miñano, Juan Carlos; Benitez, Pablo; Alvarez, Roberto
2006-08-01
Brightness enhancement of backlighting for displays is typically achieved via crossed micro prismatic films that are introduced between a backlight unit and a transmissive (LCD) display. Prismatic films let pass light only into a restricted angular range, while, in conjunction with other reflective elements below the backlight, all other light is recycled within the backlight unit, thereby increasing the backlight luminance. This design offers no free parameters to influence the resulting light distribution and suffers from insufficient stray light control. A novel strategy of light recycling is introduced, using a microlens array in conjunction with a hole array in a reflective surface, that can provide higher luminance, superior stray light control, and can be designed to meet almost any desired emission pattern. Similar strategies can be applied to mix light from different colored LEDs being mounted upside down to shine into a backlight unit.
Actively addressed single pixel full-colour plasmonic display
NASA Astrophysics Data System (ADS)
Franklin, Daniel; Frank, Russell; Wu, Shin-Tson; Chanda, Debashis
2017-05-01
Dynamic, colour-changing surfaces have many applications including displays, wearables and active camouflage. Plasmonic nanostructures can fill this role by having the advantages of ultra-small pixels, high reflectivity and post-fabrication tuning through control of the surrounding media. However, previous reports of post-fabrication tuning have yet to cover a full red-green-blue (RGB) colour basis set with a single nanostructure of singular dimensions. Here, we report a method which greatly advances this tuning and demonstrates a liquid crystal-plasmonic system that covers the full RGB colour basis set, only as a function of voltage. This is accomplished through a surface morphology-induced, polarization-dependent plasmonic resonance and a combination of bulk and surface liquid crystal effects that manifest at different voltages. We further demonstrate the system's compatibility with existing LCD technology by integrating it with a commercially available thin-film-transistor array. The imprinted surface interfaces readily with computers to display images as well as video.
NASA Astrophysics Data System (ADS)
Al-Kuhali, K.; Hussain M., I.; Zain Z., M.; Mullenix, P.
2015-05-01
Aim: This paper contribute to the flat panel display industry it terms of aggregate production planning. Methodology: For the minimization cost of total production of LCD manufacturing, a linear programming was applied. The decision variables are general production costs, additional cost incurred for overtime production, additional cost incurred for subcontracting, inventory carrying cost, backorder costs and adjustments for changes incurred within labour levels. Model has been developed considering a manufacturer having several product types, which the maximum types are N, along a total time period of T. Results: Industrial case study based on Malaysia is presented to test and to validate the developed linear programming model for aggregate production planning. Conclusion: The model development is fit under stable environment conditions. Overall it can be recommended to adapt the proven linear programming model to production planning of Malaysian flat panel display industry.
Optical engineering challenges of the virtual retinal display
NASA Astrophysics Data System (ADS)
Kollin, Joel S.; Tidwell, Michael R.
1995-08-01
The Virtual Retinal Display (VRD) is a unique approach to developing a high-resolution head- mounted display currently under development at the University of Washington's Human Interface Technology (HIT) Laboratory. Rather than looking at a screen though a magnifier or optical relay system, the viewer of the VRD has a scanned beam of light enter the pupil of the eye and focused to a spot on the retina. This type of optical system is subject to different design constraints than a typical HMD. With the VRD it may be possible to realize higher resolution, greater color saturation, higher brightness and larger field-of-view than a traditional LCD or CRT screen-based system. In this paper the author will present the VRD approach and how it can provide these advantages. Issues to be resolved for the VRD to reach its full potential and some of the solutions developed at the HIT lab will also be discussed.
Min, Kyungjin; Yoon, Hye-Jin; Matsuura, Atsushi; Kim, Yong Hwan; Lee, Hyung Ho
2018-04-30
L-pipecolic acid is a non-protein amino acid commonly found in plants, animals, and microorganisms. It is a well-known precursor to numerous microbial secondary metabolites and pharmaceuticals, including anticancer agents, immunosuppressants, and several antibiotics. Lysine cyclodeaminase (LCD) catalyzes β-deamination of L-lysine into L-pipecolic acid using β-nicotinamide adenine dinucleotide as a cofactor. Expression of a human homolog of LCD, μ-crystallin, is elevated in prostate cancer patients. To understand the structural features and catalytic mechanisms of LCD, we determined the crystal structures of Streptomyces pristinaespiralis LCD (SpLCD) in (i) a binary complex with NAD + , (ii) a ternary complex with NAD + and L-pipecolic acid, (iii) a ternary complex with NAD + and L-proline, and (iv) a ternary complex with NAD + and L-2,4-diamino butyric acid. The overall structure of SpLCD was similar to that of ornithine cyclodeaminase from Pseudomonas putida . In addition, SpLCD recognized L-lysine, L-ornithine, and L-2,4-diamino butyric acid despite differences in the active site, including differences in hydrogen bonding by Asp236, which corresponds with Asp228 from Pseudomonas putida ornithine cyclodeaminase. The substrate binding pocket of SpLCD allowed substrates smaller than lysine to bind, thus enabling binding to ornithine and L-2,4-diamino butyric acid. Our structural and biochemical data facilitate a detailed understanding of substrate and product recognition, thus providing evidence for a reaction mechanism for SpLCD. The proposed mechanism is unusual in that NAD + is initially converted into NADH and then reverted back into NAD + at a late stage of the reaction.
Mutch, David M; Pers, Tune H; Temanni, M Ramzi; Pelloux, Veronique; Marquez-Quiñones, Adriana; Holst, Claus; Martinez, J Alfredo; Babalis, Dimitris; van Baak, Marleen A; Handjieva-Darlenska, Teodora; Walker, Celia G; Astrup, Arne; Saris, Wim H M; Langin, Dominique; Viguerie, Nathalie; Zucker, Jean-Daniel; Clément, Karine
2011-12-01
Weight loss has been shown to reduce risk factors associated with cardiovascular disease and diabetes; however, successful maintenance of weight loss continues to pose a challenge. The present study was designed to assess whether changes in subcutaneous adipose tissue (scAT) gene expression during a low-calorie diet (LCD) could be used to differentiate and predict subjects who experience successful short-term weight maintenance from subjects who experience weight regain. Forty white women followed a dietary protocol consisting of an 8-wk LCD phase followed by a 6-mo weight-maintenance phase. Participants were classified as weight maintainers (WMs; 0-10% weight regain) and weight regainers (WRs; 50-100% weight regain) by considering changes in body weight during the 2 phases. Anthropometric measurements, bioclinical variables, and scAT gene expression were studied in all individuals before and after the LCD. Energy intake was estimated by using 3-d dietary records. No differences in body weight and fasting insulin were observed between WMs and WRs at baseline or after the LCD period. The LCD resulted in significant decreases in body weight and in several plasma variables in both groups. WMs experienced a significant reduction in insulin secretion in response to an oral-glucose-tolerance test after the LCD; in contrast, no changes in insulin secretion were observed in WRs after the LCD. An ANOVA of scAT gene expression showed that genes regulating fatty acid metabolism, citric acid cycle, oxidative phosphorylation, and apoptosis were regulated differently by the LCD in WM and WR subjects. This study suggests that LCD-induced changes in insulin secretion and scAT gene expression may have the potential to predict successful short-term weight maintenance. This trial was registered at clinicaltrials.gov as NCT00390637.
A spectroscopy-based detector to monitor tomato growth condition in greenhouse
NASA Astrophysics Data System (ADS)
Yang, Ce; Li, Minzan; Cui, Di
2008-12-01
A spectroscopy-based detector is developed to measure the nitrogen and chlorophyll content of tomato leaves and then to predict the growth condition of tomato plants in greenhouse. The detector uses two wavebands, 527 nm and 762 nm, since it is proved that these wavebands are sensitive to nitrogen and chlorophyll content in plant leaves by previous field test. The detector contains: A Y-type optic fiber, two silicon photocells, a signal processing unit, and a MCU. Light reflection from tomato leaves is transmitted by the Y-type optic fiber to the surface of the silicon photo cells, which transfer optical signal into electrical signal. Then the analog signal is amplified to conform to the TTL level signal standard and finally converted to digital signal by MAX186. After that, the MCU carries on a series of actions, including data calculating, displaying and storage. Using the measured data, the Normalized Difference Vegetation Index (NDVI) is calculated to estimate the nitrogen and chlorophyll content in plant leaves. The result is directly displayed on an LCD screen. Users have an option in saving data, either into a USB-memory stick or into a database over the PC serial port. The detector is portable, inexpensive, and convenient, which make it meet farmers' need in China. The performance test shows that the growth model works very well, and the device has high accuracy in predicting the growth condition of tomato plants in greenhouse.
Kim, MinSu; Ham, Hyeong Gyun; Choi, Han-Sol; Bos, Philip J; Yang, Deng-Ke; Lee, Joong Hee; Lee, Seung Hee
2017-03-20
The demands for a power-saving mode for displaying static images are ubiquitous not only in portable devices but also in price tags and advertising panels. At a low-frequency driving in liquid crystal displays (LCDs) for low-power consumption, the flexoelectric effect arises even in calamitic liquid crystals and the optical appearance of this physical phenomenon is found to be unusually large, being noticed as an image-flickering. Although the inherent integrated optical transmittance of in-plane switching (IPS) mode is relatively lower than that of fringe-field switching (FFS) mode, the IPS mode shows no static image-flickering but an optical spike (the so-called optical bounce), at the transient moment between signal positive and negative frames. Here, we demonstrate an IPS mode using negative dielectric anisotropy of liquid crystals (Δε < 0) and fine-patterned electrodes (the width w of and the space l between electrodes ≤ 3 μm) with reduced operation voltage (up to 40.7% to a conventional FFS mode with Δε < 0), reduced optical bounce (up to 4.4%. to a conventional FFS mode with Δε < 0) and enhanced transmittance (up to 32.1% to a conventional IPS mode with Δε > 0). We believe the result will contribute not only to the scientific understanding of the optical appearance of flexoelectric effect but also pave the way for engineering of a superior low-power consumption LCD.
Info Based Med Emergency Decision Tools, Rural Mobil Comm
2006-10-01
through its ability to deliver and manage a wide variety of environmental sensors – in short, a robotic equivalent of hearing, sight, smell, taste, and...spread of infection . Panasonic Rugged Laptop: At the time of the evaluation, the Panasonic Toughbook was regarded as the industry standard for...a patient’s systolic and diastolic blood pressure, pulse rate, temperature, and oxygen saturation ( SpO2 ). The front of the device contains an LCD
MBR/RO/ozone processes for TFT-LCD industrial wastewater treatment and recycling.
Chen, T K; Ni, C H; Chan, Y C; Lu, M C
2005-01-01
This research is mainly to explore the treatment capacity for TFT-LCD industrial wastewater recycling by the processes combined with membrane bioreactor (MBR), reverse osmosis (RO) and ozone(O3). The organic wastewater from the TFT-LCD industry was selected as the target. MBR, RO and ozone plants were established for evaluation. An MBR plant consisted of a 2-stage anoxic/aerobic bioreactor and an immersed UF membrane unit was employed. The effluent of MBR was conducted into the RO system then into the ozone system. The RO system consisted of a spiral membrane in the vessel. One bubble column, 75 cm high and diameter 5 cm, were used as the ozonation reactor. On the bottom of ozonation reactor is a porous diffuser for releasing gas, with an aperture of 100 microm (0.1 cm). Over the whole experimental period, the MBR process achieved a satisfactory organic removal. The COD could be removed with an average of over 98.5%. For the TOC item, the average removal efficiency was 97.4%. The stable effluent quality and satisfactory removal performance were ensured by the efficient interception performance of an immersed UF membrane device incorporated with the biological reactor. Moreover, the MBR effluent did not contain any suspended solids and the SDI value was under 3. After the treatment of RO, excellent water quality was found. The water quality of permeate was under 5 mg/I, 2 mg/l and 50 micros/cm for COD, TOC and conductivity respectively. The treated water can be recycled and reused for the cooling tower make-up water or other purposes. After the treatment of ozone, the treated water quality was under 5 mg/l and 0.852 mg/l for COD and TOC respectively. The test results of MBR, MBR/RO and MBR/RO/ozone processes were compared as possible appropriate treatment technologies applied in TFT-LCD industrial wastewater reuse and recycling.
Improving color characteristics of LCD
NASA Astrophysics Data System (ADS)
Feng, Xiao-fan; Daly, Scott J.
2005-01-01
The drive for larger size, higher spatial resolution, and wider aperture LCD has shown to increase the electrical crosstalk between electrodes in the driver circuit. This crosstalk leads to additivity errors in color LCD. In this paper, the crosstalk effect was analyzed with micrographs captured from an imaging colorimeter. The experimental result reveals the subpixel nature of color crosstalk. A spatial-based subpixel crosstalk correction algorithm was developed to improve the color performance of LCD. Compared to a 3D lookup table approach, the new algorithm is easier to implement and more accurate in performance.
Touch Interaction with 3D Geographical Visualization on Web: Selected Technological and User Issues
NASA Astrophysics Data System (ADS)
Herman, L.; Stachoň, Z.; Stuchlík, R.; Hladík, J.; Kubíček, P.
2016-10-01
The use of both 3D visualization and devices with touch displays is increasing. In this paper, we focused on the Web technologies for 3D visualization of spatial data and its interaction via touch screen gestures. At the first stage, we compared the support of touch interaction in selected JavaScript libraries on different hardware (desktop PCs with touch screens, tablets, and smartphones) and software platforms. Afterward, we realized simple empiric test (within-subject design, 6 participants, 2 simple tasks, LCD touch monitor Acer and digital terrain models as stimuli) focusing on the ability of users to solve simple spatial tasks via touch screens. An in-house testing web tool was developed and used based on JavaScript, PHP, and X3DOM languages and Hammer.js libraries. The correctness of answers, speed of users' performances, used gestures, and a simple gesture metric was recorded and analysed. Preliminary results revealed that the pan gesture is most frequently used by test participants and it is also supported by the majority of 3D libraries. Possible gesture metrics and future developments including the interpersonal differences are discussed in the conclusion.
Teachers' Remarks on Interactive Whiteboard with LCD Panel Technology
ERIC Educational Resources Information Center
Koçak, Ömer; Gülcü, Aslan
2013-01-01
This study investigated the opinions of teachers about using interactive whiteboards with an LCD panel that was installed in classrooms within the FATIH educational project. The study was conducted at six high schools in which installation of interactive whiteboards with an LCD panel in classrooms was completed and teachers who received training…
Analysis of circadian properties and healthy levels of blue light from smartphones at night.
Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag
2015-06-18
This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display.
Ghosting in anaglyphic stereoscopic images
NASA Astrophysics Data System (ADS)
Woods, Andrew J.; Rourke, Tegan
2004-05-01
Anaglyphic 3D images are an easy way of displaying stereoscopic 3D images on a wide range of display types, e.g. CRT, LCD, print, etc. While the anaglyphic 3D image method is cheap and accessible, its use requires a compromise in stereoscopic image quality. A common problem with anaglyphic 3D images is ghosting. Ghosting (or crosstalk) is the leaking of an image to one eye, when it is intended exclusively for the other eye. Ghosting degrades the ability of the observer to fuse the stereoscopic image and hence the quality of the 3D image is reduced. Ghosting is present in various levels with most stereoscopic displays, however it is often particularly evident with anaglyphic 3D images. This paper describes a project whose aim was to characterize the presence of ghosting in anaglyphic 3D images due to spectral issues. The spectral response curves of several different display types and several different brands of anaglyph glasses were measured using a spectroradiometer or spectrophotometer. A mathematical model was then developed to predict the amount of crosstalk in anaglyphic 3D images when different combinations of displays and glasses are used, and therefore predict the best type of anaglyph glasses for use with a particular display type.
The Effect of Low-Carbohydrate Diet on Glycemic Control in Patients with Type 2 Diabetes Mellitus.
Wang, Li-Li; Wang, Qi; Hong, Yong; Ojo, Omorogieva; Jiang, Qing; Hou, Yun-Ying; Huang, Yu-Hua; Wang, Xiao-Hua
2018-05-23
In China, a low-fat diet (LFD) is mainly recommended to help improve blood glucose levels in patients with type 2 diabetes mellitus (T2DM). However, a low-carbohydrate diet (LCD) has been shown to be effective in improving blood glucose levels in America and England. A few studies, primarily randomized controlled trials, have been reported in China as well. Firstly, we designed two 'six-point formula' methods, which met the requirements of LCD and LFD, respectively. Fifty-six T2DM patients were recruited and randomly allocated to the LCD group ( n = 28) and the LFD group ( n = 28). The LCD group received education about LCD's six-point formula, while the LFD group received education about LFD's six-point formula. The follow-up time was three months. The indicators for glycemic control and other metabolic parameters were collected and compared between the two groups. Forty-nine patients completed the study. The proportions of calories from three macronutrients the patients consumed met the requirements of LCD and LFD. Compared to the LFD group, there was a greater decrease in HbA1c level in the LCD group (-0.63% vs. -0.31%, p < 0.05). The dosages of insulin and fasting blood glucoses (FBG) in the third month were lower than those at baseline in both groups. Compared with baseline values, body mass index (BMI) and total cholesterol (TC) in the LCD group were significantly reduced in the third month ( p < 0.05); however, there were no statistically significant differences in the LFD group. LCD can improve blood glucose more than LFD in Chinese patients with T2DM. It can also regulate blood lipid, reduce BMI, and decrease insulin dose in patients with T2DM. In addition, the six-point formula is feasible, easily operable, and a practical educational diet for Chinese patients with T2DM.
Effect of black point on accuracy of LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; He, Nannan; Ye, Yushan
2018-03-01
Black point is the point at which RGB's single channel digital drive value is 0. Due to the problem of light leakage of liquid-crystal displays (LCDs), black point's luminance value is not 0, this phenomenon bring some errors to colorimetric characterization of LCDs, especially low luminance value driving greater sampling effect. This paper describes the characteristic accuracy of polynomial model method and the effect of black point on accuracy, the color difference accuracy is given. When considering the black point in the characteristics equation, the maximum color difference is 3.246, the maximum color difference than without considering the black points reduced by 2.36. The experimental results show that the accuracy of LCDs colorimetric characterization can be improved, if the effect of black point is eliminated properly.
An Examination of the MH-60S Common Cockpit from a Design Methodology and Acquisitions Standpoint
2009-06-01
estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington headquarters Services...LCD monitors and a host of keypads and other more “computer interface” oriented input devices. To the author, the potential of this transition was...year during fiscal years 1998–2003 but had shifted these monies to other priorities [21]. This mess quickly drew in the Marine Corps again, this
72-directional display having VGA resolution for high-appearance image generation
NASA Astrophysics Data System (ADS)
Takaki, Yasuhiro; Dairiki, Takeshi
2006-02-01
The high-density directional display, which was originally developed in order to realize a natural 3D display, is not only a 3D display but also a high-appearance display. The appearances of objects, such as glare and transparency, are the results of the reflection and the refraction of rays. The faithful reproduction of such appearances of objects is impossible using conventional 2D displays because rays diffuse on the display screen. The high-density directional display precisely controls the horizontal ray directions so that it can reproduce the appearances of objects. The fidelity of the reproduction of object appearances depends on the ray angle sampling pitch. The angle sampling pitch is determined by considering the human eye imaging system. In the present study the high-appearance display which has the resolution of 640×400 and emits rays in 72 different horizontal directions with the angle pitch of 0.38° was constructed. Two 72-directional displays were combined, each of which consisted of a high-resolution LCD panel (3,840×2,400) and a slanted lenticular sheet. Two images produced by two displays were superimposed by a half mirror. A slit array was placed at the focal plane of the lenticular sheet for each display to reduce the horizontal image crosstalk in the combined image. The impression analysis shows that the high-appearance display provides higher appearances and presence than the conventional 2D displays do.
Design for low-power and reliable flexible electronics
NASA Astrophysics Data System (ADS)
Huang, Tsung-Ching (Jim)
Flexible electronics are emerging as an alternative to conventional Si electronics for large-area low-cost applications such as e-paper, smart sensors, and disposable RFID tags. By utilizing inexpensive manufacturing methods such as ink-jet printing and roll-to-roll imprinting, flexible electronics can be made on low-cost plastics just like printing a newspaper. However, the key elements of exible electronics, thin-film transistors (TFTs), have slower operating speeds and less reliability than their Si electronics counterparts. Furthermore, depending on the material property, TFTs are usually mono-type -- either p- or n-type -- devices. Making air-stable complementary TFT circuits is very challenging and not applicable to most TFT technologies. Existing design methodologies for Si electronics, therefore, cannot be directly applied to exible electronics. Other inhibiting factors such as high supply voltage, large process variation, and lack of trustworthy device modeling also make designing larger-scale and robust TFT circuits a significant challenge. The major goal of this dissertation is to provide a viable solution for robust circuit design in exible electronics. I will first introduce a reliability simulation framework that can predict the degraded TFT circuits' performance under bias-stress. This framework has been validated using the amorphous-silicon (a-Si) TFT scan driver for TFT-LCD displays. To reuse the existing CMOS design ow for exible electronics, I propose a Pseudo-CMOS cell library that can make TFT circuits operable under low supply voltage and which has post-fabrication tunability for reliability and performance enhancement. This cell library has been validated using 2V self-assembly-monolayer (SAM) organic TFTs with a low-cost shadow-mask deposition process. I will also demonstrate a 3-bit 1.25KS/s Flash ADC in a-Si TFTs, which is based on the proposed Pseudo-CMOS cell library, and explore more possibilities in display, energy, and sensing applications.
Tele-transmission of stereoscopic images of the optic nerve head in glaucoma via Internet.
Bergua, Antonio; Mardin, Christian Y; Horn, Folkert K
2009-06-01
The objective was to describe an inexpensive system to visualize stereoscopic photographs of the optic nerve head on computer displays and to transmit such images via the Internet for collaborative research or remote clinical diagnosis in glaucoma. Stereoscopic images of glaucoma patients were digitized and stored in a file format (joint photographic stereoimage [jps]) containing all three-dimensional information for both eyes on an Internet Web site (www.trizax.com). The size of jps files was between 0.4 to 1.4 MB (corresponding to a diagonal stereo image size between 900 and 1400 pixels) suitable for Internet protocols. A conventional personal computer system equipped with wireless stereoscopic LCD shutter glasses and a CRT-monitor with high refresh rate (120 Hz) can be used to obtain flicker-free stereo visualization of true-color images with high resolution. Modern thin-film transistor-LCD displays in combination with inexpensive red-cyan goggles achieve stereoscopic visualization with the same resolution but reduced color quality and contrast. The primary aim of our study was met to transmit stereoscopic images via the Internet. Additionally, we found that with both stereoscopic visualization techniques, cup depth, neuroretinal rim shape, and slope of the inner wall of the optic nerve head, can be qualitatively better perceived and interpreted than with monoscopic images. This study demonstrates high-quality and low-cost Internet transmission of stereoscopic images of the optic nerve head from glaucoma patients. The technique allows exchange of stereoscopic images and can be applied to tele-diagnostic and glaucoma research.
Brouda, Irina; Edison, Brenda; Van Cott, Alicia; Green, Barbara A
2010-04-01
Although generally recognized as an effective therapy for psoriasis, coal tar therapy lost appeal in modern clinical practice due to poor patient acceptability of its aesthetic properties. A new liquor carbonis distillate (LCD) solution 15% (equivalent to coal tar 2.3%) that uses an evaporative and transparent vehicle, fragrance, and a dab-on applicator was developed. Cosmetic acceptability of the LCD solution was compared to calcipotriene cream 0.005% during a randomized, active-controlled, investigator-blinded clinical trial. Participants with moderate plaque psoriasis applied LCD solution or calcipotriene cream twice daily to body lesions for 12 weeks and then were followed for 6 additional weeks without treatment. Participants completed a cosmetic acceptability survey about their medications after starting therapy. Mean ratings for aesthetic and product performance attributes were high in both groups; however, more participants treated with LCD solution versus calcipotriene cream rated their product as more convenient and beneficial compared to prior psoriasis therapies. Ratings of the scent, staining, drying time, and dab-on applicator for the LCD solution were favorable. Participant experience with LCD solution in this study suggests that it is a cosmetically acceptable psoriasis treatment that is comparable to calcipotriene cream.
Mayer, Stephanie B.; Jeffreys, Amy S.; Olsen, Maren K.; McDuffie, Jennifer R.; Feinglos, Mark N.; Yancy, William S.
2013-01-01
We analyzed participants with type 2 diabetes (n=46) within a larger weight loss trial (n=146) who were randomized to 48 weeks of a low-carbohydrate diet (LCD; n=22) or a low-fat diet + orlistat (LFD+O; n=24). At baseline, mean BMI was 39.5 kg/m2 (SD 6.5) and HbA1c 7.6% (SD 1.3). Although the interventions reduced BMI similarly (LCD −2.4 kg/m2; LFD+O −2.7 kg/m2, p= 0.7), LCD led to a relative improvement in hemoglobin A1c: −0.7% in LCD vs. +0.2% in LFD+O (difference −0.8%, 95% CI= −1.6, −0.02; p=0.045). LCD also led to a greater reduction in antiglycemic medications using a novel medication effect score (MES) based on medication potency and total daily dose; 70.6% of LCD vs. 30.4% LFD+O decreased their MES by ≥50% (p=0.01). Lowering dietary carbohydrate intake demonstrated benefits on glycemic control beyond its weight loss effects, while at the same time lowering antiglycemic medication requirements. PMID:23911112
Sato, Junko; Kanazawa, Akio; Makita, Sumiko; Hatae, Chie; Komiya, Koji; Shimizu, Tomoaki; Ikeda, Fuki; Tamura, Yoshifumi; Ogihara, Takeshi; Mita, Tomoya; Goto, Hiromasa; Uchida, Toyoyoshi; Miyatsuka, Takeshi; Takeno, Kageumi; Shimada, Satoshi; Ohmura, Chie; Watanabe, Takehito; Kobayashi, Kiyoe; Miura, Yoshiko; Iwaoka, Manami; Hirashima, Nao; Fujitani, Yoshio; Watada, Hirotaka
2017-08-01
The usefulness of low-carbohydrate diet (LCD) for Japanese patients with type 2 diabetes mellitus (T2DM) has not been fully investigated. Therefore, we compared the effectiveness and safety of LCD with calorie restricted diet (CRD). This prospective, randomized, open-label, comparative study included 66 T2DM patients with HbA1c >7.5% even after receiving repeated education programs on CRD. They were randomly allocated to either the 130g/day LCD group (n = 33) or CRD group (n = 33). Patients received personal nutrition education of CRD or LCD for 30 min at baseline, 1, 2, 4, and 6 months. Patients of the CRD group were advised to maintain the intake of calories and balance of macronutrients (28× ideal body weight calories per day). Patients of the LCD group were advised to maintain the intake of 130 g/day carbohydrate without other specific restrictions. Several parameters were assessed at baseline and 6 months after each intervention. The primary endpoint was a change in HbA1c level from baseline to the end of the study. At baseline, BMI and HbA1c were 26.5 (24.6-30.1) and 8.3 (8.0-9.3), and 26.7 (25.0-30.0) kg/m 2 and 8.0 (7.6-8.9) %, in the CRD and LCD, respectively. At the end of the study, HbA1c decreased by -0.65 (-1.53 to -0.10) % in the LCD group, compared with 0.00 (-0.68 to 0.40) % in the CRD group (p < 0.01). Also, the decrease in BMI in the LCD group [-0.58 (-1.51 to -0.16) kg/m 2 ] exceeded that observed in the CRD group (p = 0.03). Our study demonstrated that 6-month 130 g/day LCD reduced HbA1c and BMI in poorly controlled Japanese patients with T2DM. LCD is a potentially useful nutrition therapy for Japanese patients who cannot adhere to CRD. This trial was registered at http://www.umin.ac.jp/english/ (University Hospital Medical Information Network: study ID number 000010663). Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
NASA Astrophysics Data System (ADS)
Castro, José J.; Pozo, Antonio M.; Rubiño, Manuel
2013-11-01
In this work we studied the color dependence with a horizontal-viewing angle and colorimetric characterization of two liquid-crystal displays (LCD) using two different backlighting: Cold Cathode Fluorescent Lamps (CCFLs) and light-emitting diodes (LEDs). The LCDs studied had identical resolution, size, and technology (TFT - thin film transistor). The colorimetric measurements were made with the spectroradiometer SpectraScan PR-650 following the procedure recommended in the European guideline EN 61747-6. For each display, we measured at the centre of the screen the chromaticity coordinates at horizontal viewing angles of 0, 20, 40, 60 and 80 degrees for the achromatic (A), red (R), green (G) and blue (B) channels. Results showed a greater color-gamut area for the display with LED backlight, compared with the CCFL backlight, showing a greater range of colors perceptible by human vision. This color-gamut area diminished with viewing angle for both displays. Higher differences between trends for viewing angles were observed in the LED-backlight, especially for the R- and G-channels, demonstrating a higher variability of the chromaticity coordinates with viewing angle. The best additivity was reached by the LED-backlight display (a lower error percentage). LED-backlight display provided better color performance of visualization.
Conceptual design of wearpack with physiology detector feature based on wearable instrumentation
NASA Astrophysics Data System (ADS)
Sukirman, Melani; Laksono, Pringgo Widyo; Priadythama, Ilham; Susmartini, Susy; Suhardi, Bambang
2017-11-01
Every company in Indonesia is responsible for their worker health and safety condition as mentioned in UU No I year 1970. In manufacturing industries, there are many manual tasks dealing with high work load and risk, so that they require excellent concentration and physical condition. There is no ideal way to guarantee worker safety without a real time physiological monitoring. This paper reports our ongoing study in conceptual design development of worker's clothing which is equipped with a wearable instrumentation system. The system is designed to detect and measure body temperature and pulse in real time. Some electrical components such as, LCD (liquid crystal display), LEDs (light emitting diode), batteries, and physiological sensors were assembled. All components are controlled by a wearable on board controller. LEDs is used as alert which can indicate abnormal physical conditions. The LCD was added to provide more detail information. TMP 36 and XD-58C were selected as the physiological sensors. Finally, an Arduino Lilypad was chosen for the controller. This instrumentation system was verified by accurately detected and inform physiological condition of 3 subjects. Further we are going to attach the system to a worker's clothing which was specifically designed to simplify and comfortable usage.
Zhang, Kaihua; Li, Bin; Wu, Yufeng; Wang, Wei; Li, Rubing; Zhang, Yi-Nan; Zuo, Tieyong
2017-06-01
The tremendous amount of end-of-life liquid crystal displays (LCDs) has become one of the prominent sources of waste electrical and electronic equipment (WEEE) in recent years. Despite the necessity of safe treatment, recycling indium is also a focus of waste LCD treatment because of the scarcity of indium. Based on the analyses of the structure of Indium Tin Oxide (ITO) glass, crushing is demonstrated to be not required. In the present research, a complete non-crushing leaching method was firstly adopted to recycle indium from waste LCDs, and the ultrasonic waves was applied in the leaching process. The results demonstrated that indium can be leached efficiently with even a low concentration of chloride acid (HCl) without extra heating. About 96.80% can be recovered in 60mins, when the ITO glass was leached by 0.8MHCl with an enhancement of 300W ultrasonic waves. The indium leaching process is abridged free from crushing, and proves to be of higher efficiency. In addition, the ultrasonic wave influence on leaching process was also explained combing with micron-scale structure of ITO glass. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Takada, Yoshihiro; Fukui, Matoko; Sai, Tsunehiro
2008-11-01
Recent progresses in the photoresists and photolithography for LCD industry applications have been primarily driven by the following two factors: advancement in the material performances (high resolution, high contrast ratio, low dielectric constant) for higher display quality, and cost reduction in the fabrication process. Along with crucial demand for cost competitiveness by improving production efficiency, environmental consciousness has been a major priority at fabrication process design to minimize the amount of waste produced. Having said the above, integration of two or more fabrication processes into a single process by using multi-tone mask technology has been the interest of research, due to its obvious advantage of reducing fabrication processes and cost. For example, multi-tone mask technology application has been widely employed on the TFT side to reduce the different types of photomasks being used. Similar trend has been employed on the CF side as well, where application of multi-tone mask technology is being investigated to integrate fabrication of multiple CF micro-components into a single process. In this presentation, we demonstrate a new approach of fabricating photospacer and peripheral CF components (MVA protrusion, sub-photospacers) in a single integrated process through multi-tone mask technology.
Park, Chang-Kyun; Ho, Chang-Hoi; Jeong, Su-Jong; Lee, Eun Ju; Kim, Jinwon
2017-01-01
Understanding shifts in autumn phenology associated with climate changes is critical for preserving forest ecosystems. This study examines the changes in the leaf coloring date (LCD) of two temperate deciduous tree species, Acer palmatum (Acer) and Ginkgo biloba (Ginkgo), in response to surface air temperature (Ts) changes at 54 stations of South Korea for the period 1989-2007. The variations of Acer and Ginkgo in South Korea are very similar: they show the same mean LCD of 295th day of the year and delays of about 0.45 days year-1 during the observation period. The delaying trend is closely correlated (correlation coefficient > 0.77) with increases in Ts in mid-autumn by 2.8 days °C-1. It is noted that the LCD delaying and temperature sensitivity (days °C-1) for both tree species show negligible dependences on latitudes and elevations. Given the significant LCD-Ts relation, we project LCD changes for 2016-35 and 2046-65 using a process-based model forced by temperature from climate model simulation. The projections indicate that the mean LCD would be further delayed by 3.2 (3.7) days in 2016-35 (2046-65) due to mid-autumn Ts increases. This study suggests that the mid-autumn warming is largely responsible for the observed LCD changes in South Korea and will intensify the delaying trends in the future.
Change in food cravings, food preferences, and appetite during a low-carbohydrate and low-fat diet
Martin, C. K.; Rosenbaum, D.; Han, H.; Geiselman, P.; Wyatt, H.; Hill, J.; Brill, C.; Bailer, B.; Miller, B. V.; Stein, R.; Klein, S.; Foster, Gard D.
2011-01-01
The study objective was to evaluate the effect of prescribing a low-carbohydrate diet (LCD) and a low-fat diet (LFD) on food cravings, food preferences, and appetite. Obese adults were randomly assigned to a LCD (n=134) or a LFD (n=136) for two years. Cravings for specific types of foods (sweets, high-fats, fast-food fats, carbohydrates/starches); preferences for high-sugar, high-carbohydrate, and low-carbohydrate/high-protein foods; and appetite were measured during the trial and evaluated during this secondary analysis of trial data. Differences between the LCD and LFD on change in outcome variables were examined with mixed linear models. Compared to the LFD, the LCD had significantly larger decreases in cravings for carbohydrates/starches and preferences for high-carbohydrate and high-sugar foods. The LCD group reported being less bothered by hunger compared to the LFD group. Compared to the LCD group, the LFD group had significantly larger decreases in cravings for high-fat foods and preference for low-carbohydrate/high-protein foods. Men had larger decreases in appetite ratings compared to women. Prescription of diets that promoted restriction of specific types of foods resulted in decreased cravings and preferences for the foods that were targeted for restriction. The results also indicate that the LCD group was less bothered by hunger compared to the LFD group and that men had larger reductions in appetite compared to women. PMID:21494226
Kanazawa, Akio; Hatae, Chie; Makita, Sumiko; Komiya, Koji; Shimizu, Tomoaki; Ikeda, Fuki; Tamura, Yoshifumi; Ogihara, Takeshi; Mita, Tomoya; Goto, Hiromasa; Uchida, Toyoyoshi; Miyatsuka, Takeshi; Ohmura, Chie; Watanabe, Takehito; Kobayashi, Kiyoe; Miura, Yoshiko; Iwaoka, Manami; Hirashima, Nao; Watada, Hirotaka
2017-01-01
Background & aims Recently, we conducted a prospective randomized controlled trial (RCT) showing that a 6-month 130g/day low-carbohydrate diet (LCD) reduced HbA1c and BMI more than a calorie restricted diet (CRD). [1] To assess whether the benefits of the LCD persisted after the intensive intervention, we compared HbA1c and BMI between the LCD and CRD groups at 1 year after the end of the 6-month RCT. Methods Following the end of the 6-month RCT, patients were allowed to manage their own diets with periodic outpatient visits. One year later, we analyzed clinical and nutrition data. Results Of the 66 participants in the original study, 27 in the CRD group and 22 in the LCD group completed this trial. One year after the end of the original RCT, the carbohydrate intake was comparable between the groups (215 [189–243]/day in the CRD group and 214 (176–262) g/day in the LCD group). Compared with the baseline data, HbA1c and BMI were decreased in both groups (CRD: HbA1c -0.4 [-0.9 to 0.3] % and BMI -0.63 [-1.20 to 0.18] kg/m2; LCD: HbA1c -0.35 [-1.0 to 0.35] % and BMI -0.77 [-1.15 to -0.12] kg/m2). There were no significant differences in HbA1c and BMI between the groups. Conclusions One year after the diet therapy intervention, the beneficial effect of the LCD on reduction of HbA1c and BMI did not persist in comparison with CRD. However, combining the data of both groups, significant improvements in HbA1c and BMI from baseline were observed. Although the superiority of the LCD disappeared 1 year after the intensive intervention, these data suggest that well-constructed nutrition therapy programs, both CRD and LCD, were equally effective in improving HbA1c for at least 1 year. Trial registration University Hospital Medical Information Network (UMIN) ID000010663 PMID:29206237
Lewicka, Małgorzata; Henrykowska, Gabriela A; Pacholski, Krzysztof; Szczęsny, Artur; Dziedziczak-Buczyńska, Maria; Buczyński, Andrzej
2015-01-01
Electromagnetic radiation emitted by a variety of devices, e.g. cell phones, computers and microwaves, interacts with the human body in many ways. Research studies carried out in the last few decades have not yet resolved the issue of the effect of this factor on the human body and many questions are left without an unequivocal answer. Various biological and health-related effects have not been fully recognized. Thus further studies in this area are justified. A comparison of changes within catalase enzymatic activity and malondialdehyde concentration arising under the influence of the electromagnetic radiation emitted by car electronics, equipment used in physiotherapy and LCD monitors. The suspension of human blood platelets at a concentration of 1 × 109/0.001 dm 3, obtained from whole blood by manual apheresis, was the study material. Blood platelets were exposed to an electromagnetic field for 30 min in a laboratory stand designed for the reconstruction of the electromagnetic radiation generated by car electronics, physiotherapy equipment and LCD monitors. The changes in catalase activity and malondialdehyde concentration were investigated after the exposure and compared to the control values (unexposed material). An increase in catalase activity and malondialdehyde concentration was observed after 30 min exposure of platelets to EMF regardless of the radiation source. The most significant changes determining the degree of oxidative stress were observed after exposure to the EMF generated by car electronics. The low frequency electromagnetic fields generated by car electronics, physiotherapy equipment and LCD monitors may be a cause of oxidative stress in the human body and may lead to free radical diseases.
Actively addressed single pixel full-colour plasmonic display
Franklin, Daniel; Frank, Russell; Wu, Shin-Tson; Chanda, Debashis
2017-01-01
Dynamic, colour-changing surfaces have many applications including displays, wearables and active camouflage. Plasmonic nanostructures can fill this role by having the advantages of ultra-small pixels, high reflectivity and post-fabrication tuning through control of the surrounding media. However, previous reports of post-fabrication tuning have yet to cover a full red-green-blue (RGB) colour basis set with a single nanostructure of singular dimensions. Here, we report a method which greatly advances this tuning and demonstrates a liquid crystal-plasmonic system that covers the full RGB colour basis set, only as a function of voltage. This is accomplished through a surface morphology-induced, polarization-dependent plasmonic resonance and a combination of bulk and surface liquid crystal effects that manifest at different voltages. We further demonstrate the system's compatibility with existing LCD technology by integrating it with a commercially available thin-film-transistor array. The imprinted surface interfaces readily with computers to display images as well as video. PMID:28488671
Chemically amplified i-line positive resist for next-generation flat panel display
NASA Astrophysics Data System (ADS)
Lee, Hsing-Chieh; Lu, Ying-Hao; Huang, Shin-Yih; Lan, Wei-Jen; Hanabata, Makoto
2017-03-01
Traditional diazonaphthoquinone (DNQ) positive photoresists are widely used for TFT-LCD array process. Current LTPS technology has more than 600ppi resolution is required for small or middle-sized TFT liquid crystal display panels. One of the ways to enhance resolution is to apply i-line single exposure system instead of traditional g/h/ibroadband exposure system. We have been developing i-line chemically amplified photoresist ECA 200 series for the next generation flat panel display (FPD). ECA 200 consists of three components: a phenol resin, a photo acid generator and dissolution enhancer. We applied two different types of dissolution enhancers with two different kinds of protected groups to our resist materials. As a result, we achieved higher sensitivity, higher resolution, less footing of the resist profile and reduced standing wave effect compared with traditional DNQ photoresists. In addition, we have found further property of photoresist that does not need post exposure bake (PEB) process. This resist has a great advantage at most of current panel plants without PEB process.
Development of intelligent monitoring purifier for indoor PM 2.5
NASA Astrophysics Data System (ADS)
Lou, Guanting; Zhu, Rong; Guo, Jiangwei; Wei, Yongqing
2018-03-01
The particulate matter 2.5 (PM2.5) refers to tiny particles or droplets in the air that are two and one half microns or less in width. PM2.5 is an air pollutant that is a concern for people’s health when levels in air are high. The intelligent monitoring purifier was developed to detect indoor PM2.5 concentration before and after purification and the monitoring data could be displayed on the LCD screen, displaying different color patterns according to the concentrations. Through the Bluetooth transport module, real-time values could also display on the mobile phone and voice broadcast PM2.5 concentration level in the air. When PM2.5 concentration is higher than the setting threshold, the convection fan rotation and the speed can be remote controlled with mobile phone through the Bluetooth transport. Therefore, the efficiency and scope of the purification could be enhanced and further better air quality could be achieved.
Guldbrand, H; Dizdar, B; Bunjaku, B; Lindström, T; Bachrach-Lindström, M; Fredrikson, M; Ostgren, C J; Nystrom, F H
2012-08-01
The study aimed to compare the effects of a 2 year intervention with a low-fat diet (LFD) or a low-carbohydrate diet (LCD), based on four group meetings to achieve compliance. This was a prospective randomised parallel trial involving 61 adults with type 2 diabetes consecutively recruited in primary care and randomised by drawing ballots. Patients that did not speak Swedish could not be recruited. The primary outcomes in this non-blinded study were weight and HbA(1c). Patients on the LFD aimed for 55-60 energy per cent (E%) and those on LCD for 20 E% from carbohydrate. The mean BMI and HbA(1c) of the participants were 32.7 ± 5.4 kg/m(2) and 57.0 ± 9.2 mmol/mol, respectively. No patients were lost to follow-up. Weight loss did not differ between groups and was maximal at 6 months: LFD -3.99 ± 4.1 kg (n=31); LCD -4.31 ± 3.6 kg (n=30); p < 0.001 within groups. At 24 months, patients on the LFD had lost -2.97 ± 4.9 kg and those on LCD -2.34 ± 5.1 kg compared with baseline (p = 0.002 and p = 0.020 within groups, respectively). HbA(1c) fell in the LCD group only (LCD at 6 months -4.8 ± 8.3 mmol/mol, p = 0.004, at 12 months -2.2 ± 7.7 mmol/mol, p = 0.12; LFD at 6 months -0.9 ± 8.8 mmol/mol, p = 0.56). At 6 months, HDL-cholesterol had increased with the LCD (from 1.13 ± 0.33 mmol/l to 1.25 ± 0.47 mmol/l, p = 0.018) while LDL-cholesterol did not differ between groups. Insulin doses were reduced in the LCD group (0 months, LCD 42 ± 65 E, LFD 39 ± 51 E; 6 months, LCD 30 ± 47 E, LFD 38 ± 48 E; p = 0.046 for between-group change). Weight changes did not differ between the diet groups, while insulin doses were reduced significantly more with the LCD at 6 months, when compliance was good. Thus, aiming for 20% of energy intake from carbohydrates is safe with respect to cardiovascular risk compared with the traditional LFD and this approach could constitute a treatment alternative. ClinicalTrials.gov NCT01005498 University Hospital of Linköping Research Funds, Linköping University, the County Council of Östergötland, and the Diabetes Research Centre of Linköping University.
Peak wavelength shifts and opponent color theory
NASA Astrophysics Data System (ADS)
Ashdown, Ian; Salsbury, Marc
2007-09-01
We adapt the tenets of Hering's opponent color theory to the processing of data obtained from a tristimulus colorimeter to independently determine the intensity and possible peak wavelength shift of a narrowband LED. This information may then be used for example in an optical feedback loop to maintain constant intensity and chromaticity for a light source consisting of two LEDs with different peak wavelengths. This approach is particularly useful for LED backlighting of LCD display panels using red, green, and blue LEDs, wherein a tristimulus colorimeter can be used to maintain primary chromaticities to within broadcast standard limits in real time.
Investigation of the Helmholtz-Kohlrausch effect using wide-gamut display
NASA Astrophysics Data System (ADS)
Oh, Semin; Kwak, Youngshin
2015-01-01
The aim of this study is to investigate whether the Helmholtz-Kohlrausch effect exists among the images having various luminance and chroma levels. Firstly, five images were selected. Then each image was adjusted to have 4 different average CIECAM02 C and 5 different average CIECAM02 J. In total 20 test images were generated per each image for the psychophysical experiment. The psychophysical experiment was done in a dark room using a LCD display. To evaluate the overall perceived brightness of images a magnitude estimation method was used. Fifteen participants evaluated the brightness of each image comparing with the reference image. As a result, participants tended to evaluate the brightness higher as the average CIECAM02 J and also CIECAM02 C of the image increases proving the Helmholtz- Kohlrausch effect in images.
IR Sensor Synchronizing Active Shutter Glasses for 3D HDTV with Flexible Liquid Crystal Lenses
Han, Jeong In
2013-01-01
IR sensor synchronizing active shutter glasses for three-dimensional high definition television (3D HDTV) were developed using a flexible liquid crystal (FLC) lens. The FLC lens was made on a polycarbonate (PC) substrate using conventional liquid crystal display (LCD) processes. The flexible liquid crystal lens displayed a maximum transmission of 32% and total response time of 2.56 ms. The transmittance, the contrast ratio and the response time of the flexible liquid crystal lens were superior to those of glass liquid crystal lenses. Microcontroller unit and drivers were developed as part of a reception module with power supply for the IR sensor synchronizing active shutter glasses with the flexible liquid crystal lens prototypes. IR sensor synchronizing active shutter glasses for 3D HDTV with flexible liquid crystal lenses produced excellent 3D images viewing characteristics.
Ying, Hanxiao; Wang, Jing; Shi, Ting; Zhao, Yilei; Wang, Xin; Ouyang, Pingkai; Chen, Kequan
2018-01-01
Lysine cyclodeaminase (LCD) catalyzes the piperidine ring formation in macrolide-pipecolate natural products metabolic pathways from a lysine substrate through a combination of cyclization and deamination. This enzyme belongs to a unique enzyme class, which uses NAD + as the catalytic prosthetic group instead of as the co-substrate. To understand the molecular details of NAD + functions in lysine cyclodeaminase, we have determined four ternary crystal structure complexes of LCD-NAD + with pipecolic acid (LCD-PA), lysine (LCD-LYS), and an intermediate (LCD-INT) as ligands at 2.26-, 2.00-, 2.17- and 1.80 Å resolutions, respectively. By combining computational studies, a NAD + -mediated "gate keeper" function involving NAD + /NADH and Arg49 that control the binding and entry of the ligand lysine was revealed, confirming the critical roles of NAD + in the substrate access process. Further, in the gate opening form, a substrate delivery tunnel between ε-carboxyl moiety of Glu264 and the α-carboxyl moiety of Asp236 was observed through a comparison of four structure complexes. The LCD structure details including NAD + -mediated "gate keeper" and substrate tunnel may assist in the exploration the NAD + function in this unique enzyme class, and in regulation of macrolide-pipecolate natural product synthesis. Copyright © 2017 Elsevier Inc. All rights reserved.
deOgburn, Ryan; Leite, Jose O; Ratliff, Joseph; Volek, Jeff S; McGrane, Mary M; Fernandez, Maria Luz
2012-01-01
Excessive lipid accumulation within hepatocytes, or hepatic steatosis, is the pathognominic feature of nonalcoholic fatty liver disease (NAFLD), a disease associated with insulin resistance and obesity. Low-carbohydrate diets (LCD) improve these conditions and were implemented in this study to potentially attenuate hepatic steatosis in hypercholesterolemic guinea pigs. Male guinea pigs (n = 10 per group) were randomly assigned to consume high cholesterol (0.25 g/100 g) in either a LCD or a high-carbohydrate diet (HCD) for 12 wk. As compared with HCD, plasma LDL cholesterol was lower and plasma triglycerides were higher in animals fed the LCD diet, with no differences in plasma free fatty acids or glucose. The most prominent finding was a 40% increase in liver weight in guinea pigs fed the LCD diet despite no differences in hepatic cholesterol or triglycerides between the LCD and the HCD groups. Regardless of diet, all livers had severe hepatic steatosis on histologic examination. Regression analysis suggested that liver weight was independent of body weight and liver mass was independent of hepatic lipid content. LCD livers had more proliferating hepatocytes than did HCD livers, suggesting that in the context of cholesterol-induced hepatic steatosis, dietary carbohydrate restriction enhances liver cell proliferation. PMID:22546916
Smartphones, tablets and mobile applications for radiology.
Székely, András; Talanow, Roland; Bágyi, Péter
2013-05-01
Smartphones are phone devices that may also be used for browsing, navigation and running smaller computer programs called applications. One may consider them as compact personal computers which are primarily to be used for making phone calls. Tablets or "tablet PCs" are fully functioning standalone computers the size of a thin LCD monitor that use the screen itself for control and data input. Both of these devices may be categorized based on the mobile operating system that they use. The aim of this study is to illustrate how smartphones and tablets can be used by diagnostic imaging professionals, radiographers and residents, and to introduce relevant applications that are available for their field. A search was performed on iTunes, Android Market, Blackberry App World, and Windows Phone Marketplace for mobile applications pertinent to the field of diagnostic imaging. The following terms were applied for the search strategy: (1) radiology, (2) X-ray, (3) ultrasound, (4) MRI, (5) CT, (6) radiographer, (7) nuclear medicine. Two radiologists and one radiology resident reviewed the results. Our review was limited to english-language software. Additional applications were identified by reviewing the list of similar software provided in the description of each application. We downloaded and installed all applications that appeared relevant to an appropriate mobile phone or tablet device. We identified and reviewed a total of 102 applications. We ruled out 1 non-English application and 20 other applications that were created for entertainment purposes. Thus our final list includes 81 applications in the following five categories: diagnostic reading, decision support applications, medical books, interactive encyclopedias, and journal reading programs. Smartphones and tablets offer new opportunities for diagnostic imaging practitioners; these easy-to-use devices equipped with excellent display may be used for diagnostic reading, reference, learning, consultation, and for communication with patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Analysis of circadian properties and healthy levels of blue light from smartphones at night
Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag
2015-01-01
This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display. PMID:26085126
Analysis of circadian properties and healthy levels of blue light from smartphones at night
NASA Astrophysics Data System (ADS)
Oh, Ji Hye; Yoo, Heeyeon; Park, Hoo Keun; Do, Young Rag
2015-06-01
This study proposes representative figures of merit for circadian and vision performance for healthy and efficient use of smartphone displays. The recently developed figures of merit for circadian luminous efficacy of radiation (CER) and circadian illuminance (CIL) related to human health and circadian rhythm were measured to compare three kinds of commercial smartphone displays. The CIL values for social network service (SNS) messenger screens from all three displays were higher than 41.3 biolux (blx) in a dark room at night, and the highest CIL value reached 50.9 blx. These CIL values corresponded to melatonin suppression values (MSVs) of 7.3% and 11.4%, respectively. Moreover, smartphone use in a bright room at night had much higher CIL and MSV values (58.7 ~ 105.2 blx and 15.4 ~ 36.1%, respectively). This study also analyzed the nonvisual and visual optical properties of the three smartphone displays while varying the distance between the screen and eye and controlling the brightness setting. Finally, a method to possibly attenuate the unhealthy effects of smartphone displays was proposed and investigated by decreasing the emitting wavelength of blue LEDs in a smartphone LCD backlight and subsequently reducing the circadian effect of the display.
NASA Astrophysics Data System (ADS)
Xia, N.; Gerhardt, R. A.
2016-11-01
Solution-based fabrication methods can greatly reduce the cost and broaden the applications of transparent conducting oxides films, such as indium tin oxide (ITO) films. In this paper, we report on ITO films fabricated by spin coating methods on glass substrates with two different ITO sources: (1) a commercial ITO nanopowder water dispersion and (2) a sol-gel ITO solution. A simple and fast air annealing process was used to treat as-coated ITO films on a controlled temperature hot plate. Thermogravimetric analysis and x-ray diffraction showed that highly crystalline ITO films were formed after the annealing steps. The final ITO films had a good combination of optical properties and electrical properties, especially for films made from five layers of sol-gel ITO (92.66% transmittance and 8.7 × 10-3 Ω cm resistivity). The surface morphology and conducting network on the ITO films were characterized by non-contact and current atomic force microscopy. It was found that conducting paths were only partially connected for the nanoparticle ITO dispersion films, whereas the sol-gel ITO films had a more uniformly distributed conducting network on the surface. We also used the sol-gel ITO films to fabricate a simple liquid crystal display (LCD) device to demonstrate the excellent properties of our films.
New PSM optimized for stable resolution of fine holes in FPD
NASA Astrophysics Data System (ADS)
Imashiki, Nobuhisa; Yoshikawa, Yutaka; Hayase, Michihiko
2017-07-01
Recently, due to increases in the definition of high function panels for mobile devices such as smartphones and tablets, LCD panel TFT and OLED (organic electro luminescence display) circuits are becoming increasingly denser and more miniaturized by the year. TFT and OLED circuits are composed of several layers, such as gate, semiconductor and contact hole (C / H). It is particularly difficult to obtain a stable resolution for C/H due to the decrease in the C/H process margin (EL, DOF, MEEF) as a result of increases in the density of the circuit. Moreover, C/H productivity has also markedly decreased due to an increase in the exposure dose. In response to this, attenuated phase shift mask (Att. PSM) for large size photomasks have been proposed as a means to improve the process margin in FPD. We have developed new PSM that can further improve the process margin and the productivity of C/H via the effective positioning of a high transmittance phase shift film. Using a 1.5um sized hole as the target, we confirmed the improvement effect of the optimized PSM via a software simulation and an exposure test. Hereafter it is necessary for us to optimize the new PSM for each panel process so as to allow us to use this mask in actual processes.
NASA Astrophysics Data System (ADS)
Mozolevskis, G.; Ozols, A.; Nitiss, E.; Linina, E.; Tokmakov, A.; Rutkis, M.
2015-10-01
Liquid crystal display (LCD) industry is among the most rapidly growing and innovating industries in the world. Here continuously much effort is devoted towards developing and implementing new types of LCDs for various applications. Some types of LCDs require relatively high voltages for their operation. For example, bistable displays, in which an altering field at different frequencies is used for switching from clear to scattering states and vice versa, require electric fields at around 10 V/μm for operation. When operated at such high voltages an electrical breakdown is very likely to occur in the liquid crystal (LC) cell. This has been one of the limiting factors for such displays to reach market. In the present paper, we will report on the results of electrical breakdown investigations in high-voltage LC cells. An electrical breakdown in the cell is observed when current in the liquid crystal layer is above a specific threshold value. The threshold current is determined by conductivity of the liquid crystal as well as point defects, such as dust particles in LC layer, pinholes in coatings and electrode hillocks. In order to reduce the currents flowing through the liquid crystal layer several approaches, such as electrode patterning and adding of various buffer layers in the series with LC layer, have been tested. We demonstrate that the breakdown voltages can be significantly improved by means of adding insulating thin films. Šķidro kristālu ekrānu (LCD) industrija ir viena no visstraujāk augošajām industrijām pasaulē. Daudz pūļu un resursu tiek veltīti jauna tipa LCD izstrādē dažādiem pielietojumiem. Atsevišķa tipa LCD funkcionēšanai nepieciešami augsti spriegumi. Piemēram, bistabilos LCD, kuros izkliedējošs (ieslēgts) un dzidrs (izslēgts) stāvoklis tiek iegūts ar dažādu frekvenču maiņsprieguma palīdzību, elektriskā lauka intensitāte šķidrā kristāla slānī var sasniegt pat 10 V/μm. Augstās elektriskā lauka intensitātes dēļ ir liela varbūtība šķidro kristālu (LC) šūnā novērot elektrisko caursiti, kuras laikā LC šūna tiek sabojāta. Šis ir viens no galvenajiem iemesliem, kāpēc šāda tipa ekrāni pagaidām vēl nav komerciāli plaši pieejami. Šajā darbā mēs skaidrojam rezultātus, kas iegūti, veicot LC šūnu caursites pētījumus. Elektrisko caursiti LC šūnā novēro brīdī, kad strāva tajā pārsniedz noteiktu sliekšņa vērtību. Strāvas stipruma sliekšņa vērtību nosaka šķidrā kristāla īpatnējā vadītspējā, kā arī punktu defekti LC šūnā, piemēram, putekļi, elektrodu raupjums, caurumi u.c. Strāvas stipruma ierobežošanai šūnā šajā darbā tika izmantotas dažādas metodes - buferslāņu iekļaušana, elektroda izlīdzinošā slāņa iekļaušana, kā arī elektroda sadalīšana ar lāzera ablācijas metodi. Tiek demonstrēts, ka elektrisko lauku, pie kura novēro caursiti šūnās, ir iespējams būtiski palielināt, šūnā iekļaujot elektriskos izolējošus buferslāņus un sadalot elektrodu.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dodbiba, Gjergj, E-mail: dodbiba@sys.t.u-tokyo.ac.jp; Nagai, Hiroki; Wang Lipang
2012-10-15
Highlights: Black-Right-Pointing-Pointer Two pre-treatment methods, prior to leaching of indium from obsolete LCD modules, were described. Black-Right-Pointing-Pointer Conventional grinding and electrical disintegration have been evaluated and compared in the context of LCA. Black-Right-Pointing-Pointer Experimental data on the leaching capacity for indium and the electricity consumption of equipment were inputted into the LCA model in order to compare the environmental performance of each method. Black-Right-Pointing-Pointer An estimate for the environmental performance was calculated as the sum of six impact categories. Black-Right-Pointing-Pointer Electrical disintegration method outperforms conventional grinding in all impact categories. - Abstract: In order to develop an effective recycling systemmore » for obsolete Liquid Crystal Displays (LCDs), which would enable both the leaching of indium (In) and the recovery of a pure glass fraction for recycling, an effective liberation or size-reduction method would be an important pre-treatment step. Therefore, in this study, two different types of liberation methods: (1) conventional grinding, and (2) electrical disintegration have been tested and evaluated in the context of Life Cycle Assessment (LCA). In other words, the above-mentioned methods were compared in order to find out the one that ensures the highest leaching capacity for indium, as well as the lowest environmental burden. One of the main findings of this study was that the electrical disintegration was the most effective liberation method, since it fully liberated the indium containing-layer, ensuring a leaching capacity of 968.5 mg-In/kg-LCD. In turn, the estimate for the environmental burden was approximately five times smaller when compared with the conventional grinding.« less
Brem, M H; Böhner, C; Brenning, A; Gelse, K; Radkow, T; Blanke, M; Schlechtweg, P M; Neumann, G; Wu, I Y; Bautz, W; Hennig, F F; Richter, H
2006-11-01
To compare the diagnostic value of low-cost computer monitors and a Picture Archiving and Communication System (PACS) workstation for the evaluation of cervical spine fractures in the emergency room. Two groups of readers blinded to the diagnoses (2 radiologists and 3 orthopaedic surgeons) independently assessed-digital radiographs of the cervical spine (anterior-posterior, oblique and trans-oral-dens views). The radiographs of 57 patients who arrived consecutively to the emergency room in 2004 with clinical suspicion of a cervical spine injury were evaluated. The diagnostic values of these radiographs were scored on a 3-point scale (1 = diagnosis not possible/bad image quality, 2 = diagnosis uncertain, 3 = clear diagnosis of fracture or no fracture) on a PACS workstation and on two different liquid crystal display (LCD) personal computer monitors. The images were randomised to avoid memory effects. We used logistic mixed-effects models to determine the possible effects of monitor type on the evaluation of x ray images. To determine the overall effects of monitor type, this variable was used as a fixed effect, and the image number and reader group (radiologist or orthopaedic surgeon) were used as random effects on display quality. Group-specific effects were examined, with the reader group and additional fixed effects as terms. A significance level of 0.05 was established for assessing the contribution of each fixed effect to the model. Overall, the diagnostic score did not differ significantly between standard personal computer monitors and the PACS workstation (both p values were 0.78). Low-cost LCD personal computer monitors may be useful in establishing a diagnosis of cervical spine fractures in the emergency room.
NASA Astrophysics Data System (ADS)
Fukasawa, Hirotoshi; Horiuchi, Toshiyuki
2009-08-01
The patterning characteristics of matrix projection exposure using an analog liquid crystal display (LCD) panel in place of a reticle were investigated, in particular for oblique patterns. In addition, a new method for fabricating practical thick resist molds was developed. At first, an exposure system fabricated in past research was reconstructed. Changes in the illumination optics and the projection lens were the main improvements. Using fly's eye lenses, the illumination light intensity distribution was homogenized. The projection lens was changed from a common camera lens to a higher-grade telecentric lens. In addition, although the same metal halide lamp was used as an exposure light source, the central exposure wavelength was slightly shortened from 480 to 450 nm to obtain higher resist sensitivity while maintaining almost equivalent contrast between black and white. Circular and radial patterns with linewidths of approximately 6 µm were uniformly printed in all directions throughout the exposure field owing to these improvements. The patterns were smoothly printed without accompanying stepwise roughness caused by the cell matrix array. On the bases of these results, a new method of fabricating thick resist molds for electroplating was investigated. It is known that thick resist molds fabricated using the negative resist SU-8 (Micro Chem) are useful because very high aspect patterns are printable and the side walls are perpendicular to the substrate surfaces. However, the most suitable exposure wavelength of SU-8 is 365 nm, and SU-8 is insensitive to light of 450 nm wavelength, which is most appropriate for LCD matrix exposure. For this reason, a novel multilayer resist process was proposed, and micromolds of SU-8 of 50 µm thickness were successfully obtained. As a result, feasibility for fabricating complex resist molds including oblique patterns was demonstrated.
Hess, Anne Lundby; Carayol, Jérôme; Blædel, Trine; Hager, Jörg; Di Cara, Alessandro; Astrup, Arne; Saris, Wim H M; Larsen, Lesli Hingstrup; Valsesia, Armand
2018-01-01
Angiopoietin-like protein 3 (ANGPTL3), a liver-derived protein, plays an important role in the lipid and lipoprotein metabolism. Using data available from the DiOGenes study, we assessed the link with clinical improvements (weight, plasma lipid, and insulin levels) and changes in liver markers, alanine aminotransferase, aspartate aminotransferase (AST), adiponectin, fetuin A and B, and cytokeratin 18 (CK-18), upon low-calorie diet (LCD) intervention. We also examined the role of genetic variation in determining the level of circulating ANGPTL3 and the relation between the identified genetic markers and markers of hepatic steatosis. DiOGenes is a multicenter, controlled dietary intervention where obese participants followed an 8-week LCD (800 kcal/day, using a meal replacement product). Plasma ANGPTL3 and liver markers were measured using the SomaLogic (Boulder, CO) platform. Protein quantitative trait locus (pQTL) analyses assessed the link between more than four million common variants and the level of circulating ANGPTL3 at baseline and changes in levels during the LCD intervention. Changes in ANGPTL3 during weight loss showed only marginal association with changes in triglycerides (nominal p = 0.02) and insulin ( p = 0.04); these results did not remain significant after correcting for multiple testing. However, significant association (after multiple-testing correction) were observed between changes in ANGPTL3 and AST during weight loss ( p = 0.004) and between ANGPTL3 and CK-18 (baseline p = 1.03 × 10 -7 , during weight loss p = 1.47 × 10 -13 ). Our pQTL study identified two loci significantly associated with changes in ANGPTL3. One of these loci (the APOA4 - APOA5-ZNF259 - BUD13 gene cluster) also displayed significant association with changes in CK-18 levels during weight loss ( p = 0.007). We clarify the link between circulating levels of ANGPTL3 and specific markers of liver function. We demonstrate that changes in ANGPLT3 and CK-18 during LCD are under genetic control from trans -acting variants. Our results suggest an extended function of ANGPTL3 in the inflammatory state of liver steatosis and toward liver metabolic processes.
Li, Shanshan; Flint, Alan; Pai, Jennifer K; Forman, John P; Hu, Frank B; Willett, Walter C; Rexrode, Kathryn M; Mukamal, Kenneth J; Rimm, Eric B
2014-09-22
The healthiest dietary pattern for myocardial infarction (MI) survivors is not known. Specific long-term benefits of a low-carbohydrate diet (LCD) are unknown, whether from animal or vegetable sources. There is a need to examine the associations between post-MI adherence to an LCD and all-cause and cardiovascular mortality. We included 2258 women from the Nurses' Health Study and 1840 men from the Health Professional Follow-Up Study who had survived a first MI during follow-up and provided a pre-MI and at least 1 post-MI food frequency questionnaire. Adherence to an LCD high in animal sources of protein and fat was associated with higher all-cause and cardiovascular mortality (hazard ratios of 1.33 [95% CI: 1.06 to 1.65] for all-cause mortality and 1.51 [95% CI: 1.09 to 2.07] for cardiovascular mortality comparing extreme quintiles). An increase in adherence to an animal-based LCD prospectively assessed from the pre- to post-MI period was associated with higher all-cause mortality and cardiovascular mortality (hazard ratios of 1.30 [95% CI: 1.03 to 1.65] for all-cause mortality and 1.53 [95% CI: 1.10 to 2.13] for cardiovascular mortality comparing extreme quintiles). An increase in adherence to a plant-based LCD was not associated with lower all-cause or cardiovascular mortality. Greater adherence to an LCD high in animal sources of fat and protein was associated with higher all-cause and cardiovascular mortality post-MI. We did not find a health benefit from greater adherence to an LCD overall after MI. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Sammon, Cormac J; Petersen, Irene
2016-04-01
Studies using primary care databases often censor follow-up at the date data are last collected from clinical computer systems (last collection date (LCD)). We explored whether this results in the selective exclusion of events entered in the electronic health records after their date of occurrence, that is, backdated events. We used data from The Health Improvement Network (THIN). Using two versions of the database, we identified events that were entered into a later (THIN14) but not an earlier version of the database (THIN13) and investigated how the number of entries changed as a function of time since LCD. Times between events and the dates they were recorded were plotted as a function of time since the LCD in an effort to determine appropriate points at which to censor follow-up. There were 356 million eligible events in THIN14 and 355 million eligible events in THIN13. When comparing the two data sets, the proportion of missing events in THIN13 was highest in the month prior to the LCD (9.6%), decreasing to 5.2% at 6 months and 3.4% at 12 months. The proportion of missing events was largest for events typically diagnosed in secondary care such as neoplasms (28% in the month prior to LCD) and negligible for events typically diagnosed in primary care such as respiratory events (2% in the month prior to LCD). Studies using primary care databases, particularly those investigating events typically diagnosed outside primary care, should censor follow-up prior to the LCD to avoid underestimation of event rates. Copyright © 2016 John Wiley & Sons, Ltd.
SNE Industrial Fieldbus Interface
NASA Technical Reports Server (NTRS)
Lucena, Angel; Raines, Matthew; Oostdyk, Rebecca; Mata, Carlos
2011-01-01
Programmable logic controllers (PLCs) have very limited diagnostic and no prognostic capabilities, while current smart sensor designs do not have the capability to communicate over Fieldbus networks. The aim is to interface smart sensors with PLCs so that health and status information, such as failure mode identification and measurement tolerance, can be communicated via an industrial Fieldbus such as ControlNet. The SNE Industrial Fieldbus Interface (SIFI) is an embedded device that acts as a communication module in a networked smart sensor. The purpose is to enable a smart sensor to communicate health and status information to other devices, such as PLCs, via an industrial Fieldbus networking protocol. The SNE (Smart Network Element) is attached to a commercial off-the-shelf Any bus-S interface module through the SIFI. Numerous Anybus-S modules are available, each one designed to interface with a specific Fieldbus. Development of the SIFI focused on communications using the ControlNet protocol, but any of the Anybus-S modules can be used. The SIFI communicates with the Any-bus module via a data buffer and mailbox system on the Anybus module, and supplies power to the module. The Anybus module transmits and receives data on the Fieldbus using the proper protocol. The SIFI is intended to be connected to other existing SNE modules in order to monitor the health and status of a transducer. The SIFI can also monitor aspects of its own health using an onboard watchdog timer and voltage monitors. The SIFI also has the hardware to drive a touchscreen LCD (liquid crystal display) unit for manual configuration and status monitoring.
The effect of dietary carbohydrates in women with polycystic ovary syndrome: a systematic review.
Frary, Johanna M C; Bjerre, Kamilla P; Glintborg, Dorte; Ravn, Penille
2016-03-01
Weight loss improves ovulation, testosterone levels and insulin resistance in women with polycystic ovarian syndrome (PCOS), but the optimal diet composition is disputed. A diet low in carbohydrates (LCD) may be superior to a standard diet in terms of improving fertility, endocrine/metabolic parameters, weight loss and satiety in women with PCOS. The aim of the present study was to review the literature on the effects of LCD in PCOS, and to summarize the findings into evidence-based guidelines. A literature review based on publications in PubMed and Cochrane was carried out. The outcomes during LCD were compared to other types of diet interventions and exercise. Studies including insulin-sensitizing agents, such as metformin, were excluded. The outcomes were fertility, endocrine/metabolic parameters, weight loss and satiety. The review resulted in fifteen articles. Fertility parameters, endocrine hormones, metabolic outcomes and satiety hormones were not further improved during LCD compared to a standard diet. LCD had a 1-5% significant additional effect on weight loss compared to a standard diet. Energy restriction and weight loss in PCOS improve ovulation rates, conception, hyperandrogenemia, glucose- and insulin levels, insulin resistance and satiety hormones, whereas diet composition is of less importance. A LCD has an additional effect to caloric restriction in terms of weight loss. Conclusions are summarized as evidence-based recommendations.
Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence
NASA Astrophysics Data System (ADS)
Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas
2007-02-01
Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.
DTU BCI speller: an SSVEP-based spelling system with dictionary support.
Vilic, Adnan; Kjaer, Troels W; Thomsen, Carsten E; Puthusserypady, S; Sorensen, Helge B D
2013-01-01
In this paper, a new brain computer interface (BCI) speller, named DTU BCI speller, is introduced. It is based on the steady-state visual evoked potential (SSVEP) and features dictionary support. The system focuses on simplicity and user friendliness by using a single electrode for the signal acquisition and displays stimuli on a liquid crystal display (LCD). Nine healthy subjects participated in writing full sentences after a five minutes introduction to the system, and obtained an information transfer rate (ITR) of 21.94 ± 15.63 bits/min. The average amount of characters written per minute (CPM) is 4.90 ± 3.84 with a best case of 8.74 CPM. All subjects reported systematically on different user friendliness measures, and the overall results indicated the potentials of the DTU BCI Speller system. For subjects with high classification accuracies, the introduced dictionary approach greatly reduced the time it took to write full sentences.
High precision, fast ultrasonic thermometer based on measurement of the speed of sound in air
NASA Astrophysics Data System (ADS)
Huang, K. N.; Huang, C. F.; Li, Y. C.; Young, M. S.
2002-11-01
This study presents a microcomputer-based ultrasonic system which measures air temperature by detecting variations in the speed of sound in the air. Changes in the speed of sound are detected by phase shift variations of a 40 kHz continuous ultrasonic wave. In a test embodiment, two 40 kHz ultrasonic transducers are set face to face at a constant distance. Phase angle differences between transmitted and received signals are determined by a FPGA digital phase detector and then analyzed in an 89C51 single-chip microcomputer. Temperature is calculated and then sent to a LCD display and, optionally, to a PC. Accuracy of measurement is within 0.05 degC at an inter-transducer distance of 10 cm. Temperature variations are displayed within 10 ms. The main advantages of the proposed system are high resolution, rapid temperature measurement, noncontact measurement and easy implementation.
Kutsuna, Kenichiro; Matsuura, Yasuyuki; Fujikake, Kazuhiro; Miyao, Masaru; Takada, Hiroki
2013-01-01
Visually induced motion sickness (VIMS) is caused by sensory conflict, the disagreement between vergence and visual accommodation while observing stereoscopic images. VIMS can be measured by psychological and physiological methods. We propose a mathematical methodology to measure the effect of three-dimensional (3D) images on the equilibrium function. In this study, body sway in the resting state is compared with that during exposure to 3D video clips on a liquid crystal display (LCD) and on a head mounted display (HMD). In addition, the Simulator Sickness Questionnaire (SSQ) was completed immediately afterward. Based on the statistical analysis of the SSQ subscores and each index for stabilograms, we succeeded in determining the quantity of the VIMS during exposure to the stereoscopic images. Moreover, we discuss the metamorphism in the potential functions to control the standing posture during the exposure to stereoscopic video clips.
Elze, Tobias; Taylor, Christopher; Bex, Peter J.
2013-01-01
Purpose: In contrast to the dominant medical liquid crystal display (LCD) technology, organic light-emitting diode (OLED) monitors control the display luminance via separate light-emitting diodes for each pixel and are therefore supposed to overcome many previously documented temporal artifacts of medical LCDs. We assessed the temporal and luminance characteristics of the only currently available OLED monitor designed for use in the medical treatment field (SONY PVM2551MD) and checked the authors’ main findings with another SONY OLED device (PVM2541). Methods: Temporal properties of the photometric output were measured with an optical transient recorder. Luminances of the three color primaries and white for all 256 digital driving levels (DDLs) were measured with a spectroradiometer. Between the luminances of neighboring DDLs, just noticeable differences were calculated according to a perceptual model developed for medical displays. Luminances of full screen (FS) stimuli were compared to luminances of smaller stimuli with identical DDLs. Results: All measured luminance transition times were below 300 μs. Luminances were independent of the luminance in the preceding frame. However, for the single color primaries, up to 50.5% of the luminances of neighboring DDLs were not perceptually distinguishable. If two color primaries were active simultaneously, between 36.7% and 55.1% of neighboring luminances for increasing DDLs of the third primary were even decreasing. Moreover, luminance saturation effects were observed when too many pixels were active simultaneously. This effect was strongest for white; a small white patch was close to 400 cd/m2, but in FS the luminance of white saturated at 162 cd/m2. Due to different saturation levels, the luminance of FS green and FS yellow could exceed the luminance of FS white for identical DDLs. Conclusions: The OLED temporal characteristics are excellent and superior to those of LCDs. However, the OLEDs revealed severe perceptually relevant artifacts with implications for applicability to medical imaging. PMID:24007183
Elze, Tobias; Taylor, Christopher; Bex, Peter J
2013-09-01
In contrast to the dominant medical liquid crystal display (LCD) technology, organic light-emitting diode (OLED) monitors control the display luminance via separate light-emitting diodes for each pixel and are therefore supposed to overcome many previously documented temporal artifacts of medical LCDs. We assessed the temporal and luminance characteristics of the only currently available OLED monitor designed for use in the medical treatment field (SONY PVM2551MD) and checked the authors' main findings with another SONY OLED device (PVM2541). Temporal properties of the photometric output were measured with an optical transient recorder. Luminances of the three color primaries and white for all 256 digital driving levels (DDLs) were measured with a spectroradiometer. Between the luminances of neighboring DDLs, just noticeable differences were calculated according to a perceptual model developed for medical displays. Luminances of full screen (FS) stimuli were compared to luminances of smaller stimuli with identical DDLs. All measured luminance transition times were below 300 μs. Luminances were independent of the luminance in the preceding frame. However, for the single color primaries, up to 50.5% of the luminances of neighboring DDLs were not perceptually distinguishable. If two color primaries were active simultaneously, between 36.7% and 55.1% of neighboring luminances for increasing DDLs of the third primary were even decreasing. Moreover, luminance saturation effects were observed when too many pixels were active simultaneously. This effect was strongest for white; a small white patch was close to 400 cd/m(2), but in FS the luminance of white saturated at 162 cd/m(2). Due to different saturation levels, the luminance of FS green and FS yellow could exceed the luminance of FS white for identical DDLs. The OLED temporal characteristics are excellent and superior to those of LCDs. However, the OLEDs revealed severe perceptually relevant artifacts with implications for applicability to medical imaging.
Monocular display unit for 3D display with correct depth perception
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Hosomi, Takashi
2009-11-01
A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.
Bao, Wei; Bowers, Katherine; Tobias, Deirdre K; Olsen, Sjurdur F; Chavarro, Jorge; Vaag, Allan; Kiely, Michele; Zhang, Cuilin
2014-01-01
Background: Low-carbohydrate diets (LCDs) have been vastly popular for weight loss. The association between a low-carbohydrate dietary pattern and risk of gestational diabetes mellitus (GDM) remains unknown. Objective: We aimed to prospectively examine the association of 3 prepregnancy low-carbohydrate dietary patterns with risk of GDM. Design: We included 21,411 singleton pregnancies in the Nurses’ Health Study II. Prepregnancy LCD scores were calculated from validated food-frequency questionnaires, including an overall LCD score on the basis of intakes of carbohydrate, total protein, and total fat; an animal LCD score on the basis of intakes of carbohydrate, animal protein, and animal fat; and a vegetable LCD score on the basis of intakes of carbohydrate, vegetable protein, and vegetable fat. A higher score reflected a higher intake of fat and protein and a lower intake of carbohydrate, and it indicated closer adherence to a low-carbohydrate dietary pattern. RRs and 95% CIs were estimated by using generalized estimating equations with log-binomial models. Results: We documented 867 incident GDM pregnancies during 10 y follow-up. Multivariable-adjusted RRs (95% CIs) of GDM for comparisons of highest with lowest quartiles were 1.27 (1.06, 1.51) for the overall LCD score (P-trend = 0.03), 1.36 (1.13, 1.64) for the animal LCD score (P-trend = 0.003), and 0.84 (0.69, 1.03) for the vegetable LCD score (P-trend = 0.08). Associations between LCD scores and GDM risk were not significantly modified by age, parity, family history of diabetes, physical activity, or overweight status. Conclusions: A prepregnancy low-carbohydrate dietary pattern with high protein and fat from animal-food sources is positively associated with GDM risk, whereas a prepregnancy low-carbohydrate dietary pattern with high protein and fat from vegetable food sources is not associated with the risk. Women of reproductive age who follow a low-carbohydrate dietary pattern may consider consuming vegetable rather than animal sources of protein and fat to minimize their risk of GDM. PMID:24717341
Sources and proxy potential of long chain alkyl diols in lacustrine environments
NASA Astrophysics Data System (ADS)
Rampen, Sebastiaan W.; Datema, Mariska; Rodrigo-Gámiz, Marta; Schouten, Stefan; Reichart, Gert-Jan; Sinninghe Damsté, Jaap S.
2014-11-01
Long chain 1,13- and 1,15-alkyl diols form the base of a number of recently proposed proxies used for climate reconstruction. However, the sources of these lipids and environmental controls on their distribution are still poorly constrained. We have analyzed the long chain alkyl diol (LCD) composition of cultures of ten eustigmatophyte species, with three species from different families grown at various temperatures, to identify the effect of species composition and growth temperature on the LCD distribution. The results were compared with the LCD distribution of sixty-two lake surface sediments, and with previously reported LCD distributions from marine environments. The different families within the Eustigmatophyceae show distinct LCD patterns, with the freshwater family Eustigmataceae most closely resembling LCD distributions in both marine and lake environments. Unlike the other two eustigmatophyte families analyzed (Monodopsidaceae and Goniochloridaceae), C28 and C30 1,13-alkyl diols and C30 and C32 1,15-alkyl diols are all relatively abundant in the family Eustigmataceae, while the mono-unsaturated C32 1,15-alkyl diol was below detection limit. In contrast to the marine environment, LCD distributions in lakes did not show a clear relationship with temperature. The Long chain Diol Index (LDI), a proxy previously proposed for sea surface temperature reconstruction, showed a relatively weak correlation (R2 = 0.33) with mean annual air temperature used as an approximation for annual mean surface temperature of the lakes. A much-improved correlation (R2 = 0.74, p-value <0.001) was observed applying a multiple linear regression analysis between LCD distributions and lake temperatures reconstructed using branched tetraether lipid distributions. The obtained regression model provides good estimates of temperatures for cultures of the family Eustigmataceae, suggesting that algae belonging to this family have an important role as a source for LCDs in lacustrine environments, or, alternatively, that the main sources of LCDs are similarly affected by temperature as the Eustigmataceae. The results suggest that LCDs may have the potential to be applicable as a palaeotemperature proxy for lacustrine environments, although further calibration work is still required.
Design of aquaponics water monitoring system using Arduino microcontroller
NASA Astrophysics Data System (ADS)
Murad, S. A. Z.; Harun, A.; Mohyar, S. N.; Sapawi, R.; Ten, S. Y.
2017-09-01
This paper describes the design of aquaponics water monitoring system using Arduino microcontroller. Arduino Development Environment (IDE) software is used to develop a program for the microcontroller to communicate with multiple sensors and other hardware. The circuit of pH sensor, temperature sensor, water sensor, servo, liquid crystal displays (LCD), peristaltic pump, solar and Global System for Mobile communication (GSM) are constructed and connected to the system. The system powered by a rechargeable battery using solar energy. When the results of pH, temperature and water sensor are out of range, a notification message will be sent to a mobile phone through GSM. If the pH of water is out of range, peristaltic pump is automatic on to maintain back the pH value of water. The water sensor is fixed in the siphon outlet water flow to detect water flow from grow bed to the fish tank. In addition, servo is used to auto feeding the fish for every 12 hours. Meanwhile, the LCD is indicated the pH, temperature, siphon outlet water flow and remaining time for the next feeding cycle. The pH and temperature of water are set in the ranges of 6 to 7 and 25 °C to 30 °C, respectively.
Coating and Patterning Functional Materials for Large Area Electrofluidic Arrays
Wu, Hao; Tang, Biao; Hayes, Robert A.; Dou, Yingying; Guo, Yuanyuan; Jiang, Hongwei; Zhou, Guofu
2016-01-01
Industrialization of electrofluidic devices requires both high performance coating laminates and efficient material utilization on large area substrates. Here we show that screen printing can be effectively used to provide homogeneous pin-hole free patterned amorphous fluoropolymer dielectric layers to provide both the insulating and fluidic reversibility required for devices. Subsequently, we over-coat photoresist using slit coating on this normally extremely hydrophobic layer. In this way, we are able to pattern the photoresist by conventional lithography to provide the chemical contrast required for liquids dosing by self-assembly and highly-reversible electrofluidic switching. Materials, interfacial chemistry, and processing all contribute to the provision of the required engineered substrate properties. Coating homogeneity as characterized by metrology and device performance data are used to validate the methodology, which is well-suited for transfer to high volume production in existing LCD cell-making facilities. PMID:28773826
Coating and Patterning Functional Materials for Large Area Electrofluidic Arrays.
Wu, Hao; Tang, Biao; Hayes, Robert A; Dou, Yingying; Guo, Yuanyuan; Jiang, Hongwei; Zhou, Guofu
2016-08-19
Industrialization of electrofluidic devices requires both high performance coating laminates and efficient material utilization on large area substrates. Here we show that screen printing can be effectively used to provide homogeneous pin-hole free patterned amorphous fluoropolymer dielectric layers to provide both the insulating and fluidic reversibility required for devices. Subsequently, we over-coat photoresist using slit coating on this normally extremely hydrophobic layer. In this way, we are able to pattern the photoresist by conventional lithography to provide the chemical contrast required for liquids dosing by self-assembly and highly-reversible electrofluidic switching. Materials, interfacial chemistry, and processing all contribute to the provision of the required engineered substrate properties. Coating homogeneity as characterized by metrology and device performance data are used to validate the methodology, which is well-suited for transfer to high volume production in existing LCD cell-making facilities.
High-quality remote interactive imaging in the operating theatre
NASA Astrophysics Data System (ADS)
Grimstead, Ian J.; Avis, Nick J.; Evans, Peter L.; Bocca, Alan
2009-02-01
We present a high-quality display system that enables the remote access within an operating theatre of high-end medical imaging and surgical planning software. Currently, surgeons often use printouts from such software for reference during surgery; our system enables surgeons to access and review patient data in a sterile environment, viewing real-time renderings of MRI & CT data as required. Once calibrated, our system displays shades of grey in Operating Room lighting conditions (removing any gamma correction artefacts). Our system does not require any expensive display hardware, is unobtrusive to the remote workstation and works with any application without requiring additional software licenses. To extend the native 256 levels of grey supported by a standard LCD monitor, we have used the concept of "PseudoGrey" where slightly off-white shades of grey are used to extend the intensity range from 256 to 1,785 shades of grey. Remote access is facilitated by a customized version of UltraVNC, which corrects remote shades of grey for display in the Operating Room. The system is successfully deployed at Morriston Hospital, Swansea, UK, and is in daily use during Maxillofacial surgery. More formal user trials and quantitative assessments are being planned for the future.
Portable equipment for determining ripeness in Hass avocado using a low cost color sensor
NASA Astrophysics Data System (ADS)
Toro, Jessica; Daza, Carolina; Vega, Fabio; Diaz, Leonardo; Torres, Cesar
2015-08-01
The avocado is a one climacteric fruit that not ripe on the tree because it produces a maturation inhibitor that passes the fruit through the pedicel, the ripening occurs naturally during storage or to be induced as required. In post-harvest ripening stage is basically determined by experience of the farmer or buyer. In this word us developed portable equipment for determining ripeness is hass avocado using a low cost sensor color sensor TC3200 and LCD for display result. The prototype read of RGB color frequencies of the sensor and estimates the stage of ripeness in fourth different stages in post-harvest ripening.
Huang, Hsin-Tao; Tsai, Chuang-Chuang; Huang, Yi-Pai
2010-08-01
The UV-excited flat lighting (UFL) technique differs from conventional fluorescent lamp or LED illumination. It involves using a remote phosphor film to convert the wavelength of UV light to visible light, achieving high brightness and planar and uniform illumination. In particular, UFL can accomplish compact size, low power consumption, and symmetrical dual-sided illumination. Additionally, UFL utilizes a thermal radiation mechanism to release the large amount of heat that is generated upon illumination without thermal accumulation. These characteristics of the UFL technique can motivate a wide range of lighting applications in thin-film transistor LCD backlighting or general lighting.
Development of a microprocessor controller for stand-alone photovoltaic power systems
NASA Technical Reports Server (NTRS)
Millner, A. R.; Kaufman, D. L.
1984-01-01
A controller for stand-alone photovoltaic systems has been developed using a low power CMOS microprocessor. It performs battery state of charge estimation, array control, load management, instrumentation, automatic testing, and communications functions. Array control options are sequential subarray switching and maximum power control. A calculator keypad and LCD display provides manual control, fault diagnosis and digital multimeter functions. An RS-232 port provides data logging or remote control capability. A prototype 5 kW unit has been built and tested successfully. The controller is expected to be useful in village photovoltaic power systems, large solar water pumping installations, and other battery management applications.
A new microcontroller supervised thermoelectric renal hypothermia system.
Işik, Hakan
2005-10-01
In the present study, a thermoelectric system controlled by a microcontroller is developed to induce renal hypothermia. Temperature value was managed by 8-byte microcontroller, PIC16F877, and was programmed using microcontroller MPASM package. In order to ensure hypothermia in the kidney 1-4 modules and sensors perceiving temperature of the area can be selected. Temperature values are arranged proportionately for the selected area and the determined temperature values can be monitored from an Liquid Crystal Display (LCD) screen. The temperature range of the system is between -50 and +50 degrees C. Renal hypothermia system was tried under in vivo conditions on the kidney of a dog.
Handheld colorimeter for determination of heavy metal concentrations
NASA Astrophysics Data System (ADS)
López Ruiz, N.; Ariza, M.; Martínez Olmos, A.; Vukovic, J.; Palma, A. J.; Capitan-Vallvey, L. F.
2011-08-01
A portable instrument that measures heavy metal concentration from a colorimetric sensor array is presented. The use of eight sensing membranes, placed on a plastic support, allows to obtain the hue component of the HSV colour space of each one in order to determinate the concentration of metals present in a solution. The developed microcontroller-based system captures, in an ambient light environment, an image of the sensor array using an integrated micro-camera and shows the picture in a touch micro-LCD screen which acts as user interface. After image-processing of the regions of interest selected by the user, colour and concentration information are displayed on the screen.
A temperature controller board for the ARC controller
NASA Astrophysics Data System (ADS)
Tulloch, Simon
2016-07-01
A high-performance temperature controller board has been produced for the ARC Generation-3 CCD controller. It contains two 9W temperature servo loops and four temperature input channels and is fully programmable via the ARC API and OWL data acquisition program. PI-loop control is implemented in an on-board micro. Both diode and RTD sensors can be used. Control and telemetry data is sent via the ARC backplane although a USB-2 interface is also available. Further functionality includes hardware timers and high current drivers for external shutters and calibration LEDs, an LCD display, a parallel i/o port, a pressure sensor interface and an uncommitted analogue telemetry input.
Crystal Structure of a Phosphorylated Light Chain Domain of Scallop Smooth-Muscle Myosin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, V.S.; Robinson, H.; O-Neall-Hennessey, E.
2011-11-02
We have determined the crystal structure of a phosphorylated smooth-muscle myosin light chain domain (LCD). This reconstituted LCD is of a sea scallop catch muscle myosin with its phosphorylatable regulatory light chain (RLC SmoA). In the crystal structure, Arg{sup 16}, an arginine residue that is present in this isoform but not in vertebrate smooth-muscle RLC, stabilizes the phosphorylation site. This arginine interacts with the carbonyl group of the phosphorylation-site serine in the unphosphorylated LCD (determined previously), and with the phosphate group when the serine is phosphorylated. However, the overall conformation of the LCD is essentially unchanged upon phosphorylation. This resultmore » provides additional evidence that phosphorylation of the RLC is unlikely to act as an on-switch in regulation of scallop catch muscle myosin.« less
Castañeda-González, L M; Bacardí Gascón, M; Jiménez Cruz, A
2011-01-01
Low carbohydrate diets (LCD) have shown beneficial effects on short-term weight reduction programs for obese individuals without diabetes, but the long-term evidence of efficacy on individuals with type 2 diabetes is not conclusive. To evaluate, the effectiveness of 12 or more weeks of LCD compared to Low Fat Diet (LFD), Usual Care Diet (UCD) or Low Glycemic Index Diet (LGID) on weight reduction and AIC on type 2 diabetes individuals. A systematic review was conducted on randomized trials registered in PubMed, Cochrane and EBSCOhost from January 1st 2000 to January 1st 2010 including those with an intervention program with LCD in type 2 diabetes subjects and a follow-up ≥ 12 weeks. Available data on study design; carbohydrate composition of diet; duration of diet; and the outcomes of weight, lipid levels (total, low density lipoprotein and high-density lipoprotein cholesterol, and triglycerides), hemoglobin A1C percent and/or fasting glucose were extracted. Five studies showed greater weight reduction with LCD, of which four demonstrated no significant difference. The longest trial intervention studies did not show a difference in weight change. Only two studies showed greater reduction of A1C with LCD, including the longest intervention trial with a low carbohydrate Mediterranean diet. This review shows that there are no consistent differences in weight and A1C changes over the long-term treatment with LCD and LFD, UCD or LGID.
Hossain, M; Kim, S-R; Kitamura, S-I; Kim, D-W; Jung, S-J; Nishizawa, T; Yoshimizu, M; Oh, M-J
2009-08-01
Olive flounder artificially infected with lymphocystis disease virus (LCDV) were reared at 10, 20 and 30 degrees C for 60 days, to compare LCD-incidence. In the fish reared at 20 degrees C, lymphocystis cells appeared on the skin and fins at 35 days post-challenge, and the cumulative LCD-incidence was 80% at 60 days. High levels of LCDV, with a mean polymerase chain reaction (PCR) titre of 10(6) PCR-U mg(-1) tissue, were detected in the fins and skin of LCD-affected fish at 20 degrees C, but were not detected in the spleen, kidney, brain and intestinal tissues of these fish. No LCD clinical signs were observed in the fish reared at 10 degrees C and 30 degrees C; however, a low level of LCDV (10(3) PCR-U mg(-1) tissue) was detected in the fins and skin of these fish. By increasing the rearing temperature from 10 to 20 degrees C, lymphocystis clusters appeared on the skin and fins of the fish with no previous LCD clinical signs within 33 days after the temperature change. It was shown that permissive cells for LCDV infection exist in the epidermis of olive flounder. At low temperatures, small amounts of LCDV were able to persist over a period extended for a further 45 days in the fish epidermis, even though the fish showed no LCD clinical signs. The optimum growth temperature of LCDV is near 20 degrees C.
Lin, Fuxin; Zhao, Bing; Wu, Jun; Wang, Lijun; Jin, Zhen; Cao, Yong; Wang, Shuo
2016-08-01
OBJECT Case selection for the surgical treatment of arteriovenous malformations (AVMs) of the eloquent motor area remains challenging. The aim of this study was to determine the risk factors for worsened muscle strength after surgery in patients with this disorder. METHODS At their hospital the authors retrospectively studied 48 consecutive patients with AVMs involving motor cortex and/or the descending pathway. All patients had undergone preoperative functional MRI (fMRI) and diffusion tensor imaging (DTI), followed by resection. Both functional and angioarchitectural factors were analyzed with respect to the change in muscle strength. Functional factors included lesion-to-corticospinal tract distance (LCD) on DTI and lesion-to-activation area distance (LAD) and cortical reorganization on fMRI. Based on preoperative muscle strength, the changes in muscle strength at 1 week and 6 months after surgery were defined as short-term and long-term surgical outcomes, respectively. Statistical analysis was performed using the statistical package SPSS (version 20.0.0, IBM Corp.). RESULTS Twenty-one patients (43.8%) had worsened muscle strength 1 week after surgery. However, only 10 patients (20.8%) suffered from muscle strength worsening 6 months after surgery. The LCD was significantly correlated with short-term (p < 0.001) and long-term (p < 0.001) surgical outcomes. For long-term outcomes, patients in the 5 mm ≥ LCD > 0 mm (p = 0.009) and LCD > 5 mm (p < 0.001) categories were significantly associated with a lower risk of permanent motor worsening in comparison with patients in the LCD = 0 mm group. No significant difference was found between patients in the 5 mm ≥ LCD > 0 mm group and LCD > 5 mm group (p = 0.116). Nidus size was the other significant predictor of short-term (p = 0.021) and long-term (p = 0.016) outcomes. For long-term outcomes, the area under the ROC curve (AUC) was 0.728, and the cutoff point was 3.6 cm. Spetzler-Martin grade was not associated with short-term surgical outcomes (0.143), although it was correlated with long-term outcomes (0.038). CONCLUSIONS An AVM with a nidus in contact with tracked eloquent fibers (LCD = 0) and having a large size is more likely to be associated with worsened muscle strength after surgery in patients with eloquent motor area AVMs. Surgical treatment in these patients should be carefully considered. In patients with an LCD > 5 mm, radical resection may be considered to eliminate the risk of hemorrhage.
NASA Astrophysics Data System (ADS)
Ali, Omnia I. M.; Ismail, Nahla S.; Elgohary, Rasha M.
2016-01-01
Three simple, precise, accurate and validated derivative spectrophotometric methods have been developed for the simultaneous determination of levocetirizine dihydrochloride (LCD) and ambroxol hydrochloride (ABH) in bulk powder and in pharmaceutical formulations. The first method is a first derivative spectrophotometric method (1D) using a zero-crossing technique of measurement at 210.4 nm for LCD and at 220.0 nm for ABH. The second method employs a second derivative spectrophotometry (2D) where the measurements were carried out at 242.0 and 224.4 nm for LCD and ABH, respectively. In the third method, the first derivative of the ratio spectra was calculated and the first derivative of the ratio amplitudes at 222.8 and 247.2 nm was selected for the determination of LCD and ABH, respectively. Calibration graphs were established in the ranges of 1.0-20.0 μg mL- 1 for LCD and 4.0-20.0 μg mL- 1 for ABH using derivative and ratio first derivative spectrophotometric methods with good correlation coefficients. The developed methods have been successfully applied to the simultaneous determination of both drugs in commercial tablet dosage form.
Kinet, Maxime J; Malin, Jennifer A; Abraham, Mary C; Blum, Elyse S; Silverman, Melanie R; Lu, Yun; Shaham, Shai
2016-03-08
Apoptosis is a prominent metazoan cell death form. Yet, mutations in apoptosis regulators cause only minor defects in vertebrate development, suggesting that another developmental cell death mechanism exists. While some non-apoptotic programs have been molecularly characterized, none appear to control developmental cell culling. Linker-cell-type death (LCD) is a morphologically conserved non-apoptotic cell death process operating in Caenorhabditis elegans and vertebrate development, and is therefore a compelling candidate process complementing apoptosis. However, the details of LCD execution are not known. Here we delineate a molecular-genetic pathway governing LCD in C. elegans. Redundant activities of antagonistic Wnt signals, a temporal control pathway, and mitogen-activated protein kinase kinase signaling control heat shock factor 1 (HSF-1), a conserved stress-activated transcription factor. Rather than protecting cells, HSF-1 promotes their demise by activating components of the ubiquitin proteasome system, including the E2 ligase LET-70/UBE2D2 functioning with E3 components CUL-3, RBX-1, BTBD-2, and SIAH-1. Our studies uncover design similarities between LCD and developmental apoptosis, and provide testable predictions for analyzing LCD in vertebrates.
Reduce volume of head-up display by image stitching
NASA Astrophysics Data System (ADS)
Chiu, Yi-Feng; Su, Guo-Dung J.
2016-09-01
Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.
[Universal electrogustometer EG-1].
Pleskacz, Witold A; Wałkanis, Andrzej; Rapiejko, Piotr; Jurkiewicz, Dariusz
2009-01-01
Electrogustometry has been used as a clinical tool for diagnosis and assessment of a variety of conditions. Since the lack of versatile electrogustometer for research and diagnosis, the new electrogustometer EG-1 was developed in 2006. It was done in cooperation between Warsaw University of Technology and Military Institute of Medicine in Warsaw. EG-1 allows quantitative estimation of taste perception threshold using both static and impulse electrogustometry with bipolar electrode. It is a fully autonomous, battery powered and portable instrument. Because of small size and weight, it can be easily placed in any environment. Microprocessor controlled measurement system and user-friendly interface (LCD display with simple keyboard) make EG-1 electrogustometer very handy and flexible in operation. Data obtained during measurements is stored in the internal device memory. After taste examinations measurement data can be transferred to a personal computer via inbuilt USB port for further analysis and storage. EG-1 can generate three predefined variously shaped current impulses: sinus-, saw- and rectangle-shaped. There is an optional possibility of creating own shapes of stimulus puls by the user. The electrical parameters of generated pulses are as follow: current amplitude 1-2000 microA regulated with 1 microA step, stimulus frequency 0(DC)-500 Hz regulated with 5 Hz step, controlable fulfillment factor and signal rise time (optional for automatic measurements). The operator can trigger the stimuli via a hand switch on the bipolar electrode (with gold-plated endings), via keyboard or via additional independent hand switch. Three years of experience collected during EG-1 exploitation allowed to design a new version of electrogustometer EG-2 with a touch panel and color graphical display.
NASA Technical Reports Server (NTRS)
1997-01-01
An AGATE Concepts Demonstration was conducted at the annual National Air Transportation Association (NATA) Convention in 1997. Following a 5-minute introductory briefing, an interactive simulation of a single-pilot, single-engine aircraft was conducted. The participant was able to take off, fly a brief enroute segment, fly a Global Positioning System (GPS) approach and landing, and repeat the approach and landing segment. The participant was provided an advanced "highway-in-the-sky" presentation on both a simulated head-up display and on a large LCD head-down display to follow throughout the flight. A single-lever power control and display concept was also provided for control of the engine throughout the flight. A second head-down, multifunction display in the instrument panel provided a moving map display for navigation purposes and monitoring of the status of the aircraft's systems. An estimated 100 people observed or participated in the demonstration, and 68 surveys were collected. The pilot ratings of the participants ranged from student to Air Transport Rating with an average of 6089 hours total flight time. The overwhelming response was that technologies that simplify piloting tasks are enthusiastically welcomed by pilots of all experience levels. The increase in situation awareness and use of the head-up display were universally accepted and lauded as steps in the right direction.
Montastier, Emilie; Villa-Vialaneix, Nathalie; Caspar-Bauguil, Sylvie; Hlavaty, Petr; Tvrzicka, Eva; Gonzalez, Ignacio; Saris, Wim H. M.; Langin, Dominique; Kunesova, Marie; Viguerie, Nathalie
2015-01-01
Nutrigenomics investigates relationships between nutrients and all genome-encoded molecular entities. This holistic approach requires systems biology to scrutinize the effects of diet on tissue biology. To decipher the adipose tissue (AT) response to diet induced weight changes we focused on key molecular (lipids and transcripts) AT species during a longitudinal dietary intervention. To obtain a systems model, a network approach was used to combine all sets of variables (bio-clinical, fatty acids and mRNA levels) and get an overview of their interactions. AT fatty acids and mRNA levels were quantified in 135 obese women at baseline, after an 8-week low calorie diet (LCD) and after 6 months of ad libitum weight maintenance diet (WMD). After LCD, individuals were stratified a posteriori according to weight change during WMD. A 3 steps approach was used to infer a global model involving the 3 sets of variables. It consisted in inferring intra-omic networks with sparse partial correlations and inter-omic networks with regularized canonical correlation analysis and finally combining the obtained omic-specific network in a single global model. The resulting networks were analyzed using node clustering, systematic important node extraction and cluster comparisons. Overall, AT showed both constant and phase-specific biological signatures in response to dietary intervention. AT from women regaining weight displayed growth factors, angiogenesis and proliferation signaling signatures, suggesting unfavorable tissue hyperplasia. By contrast, after LCD a strong positive relationship between AT myristoleic acid (a fatty acid with low AT level) content and de novo lipogenesis mRNAs was found. This relationship was also observed, after WMD, in the group of women that continued to lose weight. This original system biology approach provides novel insight in the AT response to weight control by highlighting the central role of myristoleic acid that may account for the beneficial effects of weight loss. PMID:25590576
NASA Astrophysics Data System (ADS)
Brisse, H. J.; Brenot, J.; Pierrat, N.; Gaboriaud, G.; Savignoni, A.; DeRycke, Y.; Neuenschwander, S.; Aubert, B.; Rosenwald, J.-C.
2009-04-01
This study assessed and compared various image quality indices in order to manage the dose of pediatric abdominal MDCT protocols and to provide guidance on dose reduction. PMMA phantoms representing average body diameters at birth, 1 year, 5 years, 10 years and 15 years of age were scanned in a four-channel MDCT with a standard pediatric abdominal CT protocol. Image noise (SD, standard deviation of CT number), noise derivative (ND, derivative of the function of noise with respect to dose) and contrast-to-noise ratio (CNR) were measured. The 'relative' low-contrast detectability (rLCD) was introduced as a new quantity to adjust LCD to the various phantom diameters on the basis of the LCD1% assessed in a Catphan® phantom and a constant central absorbed dose. The required variations of CTDIvol16 with respect to phantom size were analyzed in order to maintain each image quality index constant. The use of a fixed SD or CNR level leads to major dose ratios between extreme patient sizes (factor 22.7 to 44 for SD, 31.7 to 51.5 for CNR2.8%), whereas fixed ND and rLCD result in acceptable dose ratios ranging between factors of 2.9 and 3.9 between extreme phantom diameters. For a 5-9 mm rLCD1%, adjusted ND values range between -0.84 and -0.11 HU mGy-1. Our data provide guidance on dose reduction on the basis of patient dimensions and the required rLCD (e.g., to get a constant 7 mm rLCD1% for abdominal diameters of 10, 13, 16, 20 and 25 cm, tube current-time product should be adjusted in order to obtain CTDIvol16 values of 6.2, 7.2, 8.8, 11.6 and 17.7 mGy, respectively).
Guldbrand, H; Lindström, T; Dizdar, B; Bunjaku, B; Östgren, C J; Nystrom, F H; Bachrach-Lindström, M
2014-11-01
To compare the effects on health-related quality of life (HRQoL) of a 2-year intervention with a low-fat diet (LFD) or a low-carbohydrate diet (LCD) based on four group-meetings to achieve compliance. To describe different aspects of taking part in the intervention following the LFD or LCD. Prospective, randomized trial of 61 adults with Type 2 diabetes mellitus. The SF-36 questionnaire was used at baseline, 6, 12 and 24 months. Patients on LFD aimed for 55-60 energy percent (E%) and those on LCD for 20 E% from carbohydrates. The patients were interviewed about their experiences of the intervention. Mean body-mass-index was 32.7 ± 5.4 kg/m(2) at baseline. Weight-loss did not differ between groups and was maximal at 6 months, LFD: -3.99 ± 4.1 kg, LCD: -4.31 ± 3.6 kg (p<0.001 within groups). There was an increase in the physical component score of SF-36 from 44.1 (10.0) to 46.7 (10.5) at 12 months in the LCD group (p < 0.009) while no change occurred in the LFD group (p < 0.03 between groups). At 12 months the physical function, bodily pain and general health scores improved within the LCD group (p values 0.042-0.009) while there was no change within the LFD group. Weight-changes did not differ between the diet groups while improvements in HRQoL only occurred after one year during treatment with LCD. No changes of HRQoL occurred in the LFD group in spite of a similar reduction in body weight. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Some Activities with Polarized Light from a Laptop LCD Screen
ERIC Educational Resources Information Center
Fakhruddin, Hasan
2008-01-01
The LCD screen of a laptop computer provides a broad, bright, and extended source of polarized light. A number of demonstrations on the properties of polarized light from a laptop computer screens are presented here.
[Bioimpedance means of skin condition monitoring during therapeutic and cosmetic procedures].
Alekseenko, V A; Kus'min, A A; Filist, S A
2008-01-01
Engineering and technological problems of bioimpedance skin surface mapping are considered. A typical design of a device based on a PIC 16F microcontroller is suggested. It includes a keyboard, LCD indicator, probing current generator with programmed frequency tuning, and units for probing current monitoring and bioimpedance measurement. The electrode matrix of the device is constructed using nanotechnology. A microcontroller-controlled multiplexor provides scanning of interelectrode impedance, which makes it possible to obtain the impedance image of the skin surface under the electrode matrix. The microcontroller controls the probing signal generator frequency and allows layer-by-layer images of skin under the electrode matrix to be obtained. This makes it possible to use reconstruction tomography methods for analysis and monitoring of the skin condition during therapeutic and cosmetic procedures.
Reducing Supply Chain GHG Emissions from LCD Panel Manufacturing Webinar
Fluorinated greenhouse gases (F-GHGs) are among the most potent and persistent greenhouse gases contributing to global climate change. Learn about the manufacturing processes which release F-GHGs, and how LCD suppliers are working to reduce emissions.
42 CFR 426.431 - ALJ's review of the LCD to apply the reasonableness standard.
Code of Federal Regulations, 2014 CFR
2014-10-01
... on the written record. (3) Close the LCD review record to the taking of evidence. (4) Treat as... provision(s) listed in the aggrieved party's complaint: (1) Consult with appropriate scientific or clinical...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bache, S; Liu, X; Loyer, E
Purpose: This work sought to quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on noise and low-contrast detectability (LCD). Methods: A water phantom and a Kagaku anthropomorphic body phantom were scanned on GE Discovery CT750 HD and LightSpeed VCT scanners (4 each) with identical scan parameters and reconstructed to 2.5mm/5.0mm thicknesses. Images of water phantom were analyzed at the scanner console with a built-in LCD tool that uses statistical methods to compute requisite CT-number contrast for 95% confidence in detection of a user-defined object size. LCD value wasmore » computed for 5mm, 3mm, and 1mm objects. Analysis of standard deviation and LCD values were performed on Kagaku phantom images within liver, stomach, and spleen. LCD value was computed for 4mm, 3mm, and 1mm objects using a benchmarked MATLAB implementation of the GE scanner-console tool. Results: Water LCD values were larger (poorer performance) for all HD scanners compared to VCT scanners. Mean scanner model difference in requisite CT-number contrast for 5mm, 3mm, and 1mm objects for 5.0mm/2.5mm images was 3.0%/3.4% (p=0.02/p=0.10), 5.3%/5.7% (0.00002/0.02), and 8.5%/8.2% (0.0004/0.002), respectively. Mean standard deviations within Kagaku phantom ROIs were greater in HD compared to VCT images, with mean differences for the liver, stomach, and spleen for 5.0mm/2.5mm of 16%/12% (p=0.04/0.10), 8%/12% (0.15/0.11), and 16%/15% (0.05/0.11), respectively. Mean LCD value difference between HD and VCT scanners over all ROIs for 4mm, 3m, and 1mm objects and 5.0mm/2.5mm was 34%/9%, 16%/8%, and 18%/10%, respectively. HD scanners outperformed VCT scanners only for the 4mm stomach object. Conclusion: Using both water and anthropomorphic phantoms, it was shown that HD scanners are outperformed by VCT scanners with respect to noise and LCD in a consistent and in most cases statistically significant manner. The relationship between statistical and clinical significance demands further work.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... Effects Devices and Image Display Devices and Components and Products Containing Same; Notice of... United States after importation of certain motion-sensitive sound effects devices and image display... devices and image display devices and components and products containing same that infringe one or more of...
Ali, Omnia I M; Ismail, Nahla S; Elgohary, Rasha M
2016-01-15
Three simple, precise, accurate and validated derivative spectrophotometric methods have been developed for the simultaneous determination of levocetirizine dihydrochloride (LCD) and ambroxol hydrochloride (ABH) in bulk powder and in pharmaceutical formulations. The first method is a first derivative spectrophotometric method ((1)D) using a zero-crossing technique of measurement at 210.4 nm for LCD and at 220.0 nm for ABH. The second method employs a second derivative spectrophotometry ((2)D) where the measurements were carried out at 242.0 and 224.4 nm for LCD and ABH, respectively. In the third method, the first derivative of the ratio spectra was calculated and the first derivative of the ratio amplitudes at 222.8 and 247.2 nm was selected for the determination of LCD and ABH, respectively. Calibration graphs were established in the ranges of 1.0-20.0 μg mL(-1) for LCD and 4.0-20.0 μg mL(-1) for ABH using derivative and ratio first derivative spectrophotometric methods with good correlation coefficients. The developed methods have been successfully applied to the simultaneous determination of both drugs in commercial tablet dosage form. Copyright © 2015 Elsevier B.V. All rights reserved.
Pérez Bartolomé, Francisco; Martínez de la Casa, Jose María; Camacho Bosca, Irene; Sáenz-Francés, Federico; Aguilar Munoa, Soledad; Martín Juan, Alberto; Garcia-Feijoo, Julian
2018-01-01
To examine interrelations between corneal biomechanics, ocular biometric variables and optic disc size (ODS), lamina cribosa depth (LCD) or thickness (LCT) in a healthy population. In a cross-sectional case-control study, the following measurements were made in 81 eyes of 81 participants: axial length, anterior chamber depth, lens thickness, and central corneal thickness using the optical biometer Lenstar LS900; and corneal hysteresis (CH), corneal resistance factor (CRF), Goldman-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) using the Ocular Response Analyzer. Serial horizontal enhanced depth imaging optical coherence tomography (EDI OCT) B-scans of the optic nerve head were obtained in each participant. Mean ODS, mean LCD, and mean LCT were measured in 11 equally spaced horizontal B-scans, excluding the LC insertion area under Bruch's membrane and scleral rim. LCD was measured in 74 of 81 eyes (91.36%); LCT in 60/81 (75.3%); ODS in 81/81 (100%). CRF was poorly, but significantly, correlated with LCT (Pearson's R = 0.264; P = 0.045). IOPcc, IOPg, CH, and ocular biometrics variables were poorly (non-significantly) correlated with LCD, LCT, and ODS. CRF was poorly but directly correlated with LCT. No association was detected between CH or ocular biometric variables and ODS, LCD, or LCT.
Life cycle assessment study of a Chinese desktop personal computer.
Duan, Huabo; Eugster, Martin; Hischier, Roland; Streicher-Porte, Martin; Li, Jinhui
2009-02-15
Associated with the tremendous prosperity in world electronic information and telecommunication industry, there continues to be an increasing awareness of the environmental impacts related to the accelerating mass production, electricity use, and waste management of electronic and electric products (e-products). China's importance as both a consumer and supplier of e-products has grown at an unprecedented pace in recent decade. Hence, this paper aims to describe the application of life cycle assessment (LCA) to investigate the environmental performance of Chinese e-products from a global level. A desktop personal computer system has been selected to carry out a detailed and modular LCA which follows the ISO 14040 series. The LCA is constructed by SimaPro software version 7.0 and expressed with the Eco-indicator'99 life cycle impact assessment method. For a sensitivity analysis of the overall LCA results, the so-called CML method is used in order to estimate the influence of the choice of the assessment method on the result. Life cycle inventory information is complied by ecoinvent 1.3 databases, combined with literature and field investigations on the present Chinese situation. The established LCA study shows that that the manufacturing and the use of such devices are of the highest environmental importance. In the manufacturing of such devices, the integrated circuits (ICs) and the Liquid Crystal Display (LCD) are those parts contributing most to the impact. As no other aspects are taken into account during the use phase, the impact is due to the way how the electricity is produced. The final process steps--i.e. the end of life phase--lead to a clear environmental benefit if a formal and modern, up-to-date technical system is assumed, like here in this study.
Advances in roll to roll processing of optics
NASA Astrophysics Data System (ADS)
Watts, Michael P. C.
2008-02-01
Today, there are a number of successful commercial applications that utilize roll to roll processing and almost all involve optics; unpatterned film, patterned film, and devices on film. The largest applications today are in holograms, and brightness enhancement film (BEF) for LCD. Solar cells are rapidly growing. These are mostly made in large captive facilities with their own proprietary equipment, materials and pattern generation capability. World wide roll to roll volume is > 100M meters2 year -1, and generates sales of > $5B. The vast majority of the sales are in BEF film by 3M.
Design of portable diagnostic system of cucumber leaf mildew
NASA Astrophysics Data System (ADS)
Wang, Y.; Chang, R. K.; Wang, Y. H.; Liu, H.; Tang, G. C.
2015-12-01
Powdery mildew is one of the major diseases of facilities vegetables. In order to achieve early, fast, and accurate diagnosis of powdery mildew, with TCS3200 color sensor and infrared sensor as detecting port and 12864 dot matrix LCD as display, the system explores the external change such as the color change of the blade in health and disease stage and change of reflection spectra. Through tracking experiment of different stages of cucumber leaves infected, the results show that the system can identify change of optical frequency values and the RGB values in the health cucumber leaves and infected cucumber leaves and thus provides effective warning alarm for controlling early disease occurrence.
Development of a canopy Solar-induced chlorophyll fluorescence measurement instrument
NASA Astrophysics Data System (ADS)
Sun, G.; Wang, X.; Niu, Zh; Chen, F.
2014-02-01
A portable solar-induced chlorophyll fluorescence detecting instrument based on Fraunhofer line principle was designed and tested. The instrument has a valid survey area of 1.3 × 1.3 meter when the height was fixed to 1.3 meter. The instrument uses sunlight as its light source. The instrument is quipped with two sets of special photoelectrical detectors with the centre wavelength at 760 nm and 771 nm respectively and bandwidth less than 1nm. Both sets of detectors are composed of an upper detector which are used for detecting incidence sunlight and a bottom detector which are used for detecting reflex light from the canopy of crop. This instrument includes photoelectric detector module, signal process module, A/D convert module, the data storage and upload module and human-machine interface module. The microprocessor calculates solar-induced fluorescence value based on the A/D values get from detectors. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's serial interface. The prototype was tested in the crop field and the results demonstrate that the instrument can measure the solar-induced chlorophyll value exactly with the correlation coefficients was 0.9 compared to the values got from Analytical Spectral Devices FieldSpec Pro spectrometer. This instrument can diagnose the plant growth status by the acquired spectral response.
Visualization of polarization state and its application in optics classroom teaching
NASA Astrophysics Data System (ADS)
Lei, Bing; Liu, Wei; Shi, Jianhua; Wang, Wei; Yao, Tianfu; Liu, Shugang
2017-08-01
Polarization of light and the related knowledge are key and difficult points in optical teaching, and they are difficult to be understood since they are very abstract concepts. To help students understand the polarization properties of light, some classroom demonstration experiments have been constructed by employing the optical source, polarizers, wave plates optical cage system and polarization axis finder (PAF). The PAF is a polarization indicating device with many linear polarizing components concentric circles, which can visualize the polarization axis's direction of linearly polarized light intuitively. With the help of these demonstration experiment systems, the conversion and difference between the linear polarized light and circularly polarized light have been observed directly by inserting or removing a quarter-wave plate. The rotation phenomenon of linearly polarized light's polarization axis when it propagates through an optical active medium has been observed and studied in experiment, and the strain distribution of some mounted and unmounted lenses have also been demonstrated and observed in experiment conveniently. Furthermore, some typical polarization targets, such as liquid crystal display (LCD), polarized dark glass and skylight, have been observed based on PAF, which is quite suitable to help students understand these targets' polarization properties and the related physical laws. Finally, these demonstration experimental systems have been employed in classroom teaching of our university in physical optics, optoelectronics and photoelectric detection courses, and they are very popular with teachers and students.
Sanga, Ramesh; Agarwal, Sourabh; Sivaramakrishna, M; Rao, G Prabhakara
2018-04-01
Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.
NASA Astrophysics Data System (ADS)
Sanga, Ramesh; Agarwal, Sourabh; Sivaramakrishna, M.; Rao, G. Prabhakara
2018-04-01
Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ˜2.5 kHz/mm.
Subjective evaluation of HEVC in mobile devices
NASA Astrophysics Data System (ADS)
Garcia, Ray; Kalva, Hari
2013-03-01
Mobile compute environments provide a unique set of user needs and expectations that designers must consider. With increased multimedia use in mobile environments, video encoding methods within the smart phone market segment are key factors that contribute to positive user experience. Currently available display resolutions and expected cellular bandwidth are major factors the designer must consider when determining which encoding methods should be supported. The desired goal is to maximize the consumer experience, reduce cost, and reduce time to market. This paper presents a comparative evaluation of the quality of user experience when HEVC and AVC/H.264 video coding standards were used. The goal of the study was to evaluate any improvements in user experience when using HEVC. Subjective comparisons were made between H.264/AVC and HEVC encoding standards in accordance with Doublestimulus impairment scale (DSIS) as defined by ITU-R BT.500-13. Test environments are based on smart phone LCD resolutions and expected cellular bit rates, such as 200kbps and 400kbps. Subjective feedback shows both encoding methods are adequate at 400kbps constant bit rate. However, a noticeable consumer experience gap was observed for 200 kbps. Significantly less H.264 subjective quality is noticed with video sequences that have multiple objects moving and no single point of visual attraction. Video sequences with single points of visual attraction or few moving objects tended to have higher H.264 subjective quality.
Design of a high-resolution optoelectronic retinal prosthesis.
Palanker, Daniel; Vankov, Alexander; Huie, Phil; Baccus, Stephen
2005-03-01
It has been demonstrated that electrical stimulation of the retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. However, current retinal implants provide very low resolution (just a few electrodes), whereas at least several thousand pixels would be required for functional restoration of sight. This paper presents the design of an optoelectronic retinal prosthetic system with a stimulating pixel density of up to 2500 pix mm(-2) (corresponding geometrically to a maximum visual acuity of 20/80). Requirements on proximity of neural cells to the stimulation electrodes are described as a function of the desired resolution. Two basic geometries of sub-retinal implants providing required proximity are presented: perforated membranes and protruding electrode arrays. To provide for natural eye scanning of the scene, rather than scanning with a head-mounted camera, the system operates similar to 'virtual reality' devices. An image from a video camera is projected by a goggle-mounted collimated infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. The goggles are transparent to visible light, thus allowing for the simultaneous use of remaining natural vision along with prosthetic stimulation. Optical delivery of visual information to the implant allows for real-time image processing adjustable to retinal architecture, as well as flexible control of image processing algorithms and stimulation parameters.
Design of a high-resolution optoelectronic retinal prosthesis
NASA Astrophysics Data System (ADS)
Palanker, Daniel; Vankov, Alexander; Huie, Phil; Baccus, Stephen
2005-03-01
It has been demonstrated that electrical stimulation of the retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. However, current retinal implants provide very low resolution (just a few electrodes), whereas at least several thousand pixels would be required for functional restoration of sight. This paper presents the design of an optoelectronic retinal prosthetic system with a stimulating pixel density of up to 2500 pix mm-2 (corresponding geometrically to a maximum visual acuity of 20/80). Requirements on proximity of neural cells to the stimulation electrodes are described as a function of the desired resolution. Two basic geometries of sub-retinal implants providing required proximity are presented: perforated membranes and protruding electrode arrays. To provide for natural eye scanning of the scene, rather than scanning with a head-mounted camera, the system operates similar to 'virtual reality' devices. An image from a video camera is projected by a goggle-mounted collimated infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. The goggles are transparent to visible light, thus allowing for the simultaneous use of remaining natural vision along with prosthetic stimulation. Optical delivery of visual information to the implant allows for real-time image processing adjustable to retinal architecture, as well as flexible control of image processing algorithms and stimulation parameters.
Llanos, Adana Am; Krok, Jessica L; Peng, Juan; Pennell, Michael L; Olivo-Marston, Susan; Vitolins, Mara Z; Degraffinreid, Cecilia R; Paskett, Electra D
2014-01-01
The most effective dietary pattern for breast cancer prevention has been greatly debated in recent years. Studies have examined hypocaloric diets, with particular emphasis on macronutrient composition, yielding inconclusive data. The objective of this study was to examine the effects of calorie-restricted low-fat and low-carbohydrate diets (LFD and LCD, respectively) on circulating adipokines among overweight and obese premenopausal women. Seventy-nine overweight and obese premenopausal women were randomized to either LFD or LCD, with increased physical activity, for 52 weeks. Serum adiponectin, leptin and the adiponectin-to-leptin ratio (A/L) were measured at baseline, and at weeks 34 and 52 to assess intervention effects. While there were no significant changes in serum adiponectin concentrations following the LCD and LFD interventions, leptin concentrations significantly decreased by week 34 of the intervention period (LCD: 35.3%, P = 0.004; LFD: 30.0%, P = 0.01), with no difference by intervention arm. At week 52, these reductions were statistically non-significant, indicating a return to baseline levels by the end of the intervention. While there were non-significant increases in the A/L ratio following the LCD and LFD intervention arms, the overall trend, across groups, was marginally significant (P = 0.05) with increases of 16.2% and 35.1% at weeks 34 and 52, respectively. These findings suggest that caloric-restricted LCD and LFD dietary patterns favorably modify leptin and possibly the A/L ratio, and lend support to the hypothesis that these interventions may be effective for obesity-related breast cancer prevention through their effects on biomarkers involved in metabolic pathways. NCT01559194.
Tomita, Ryouichi
2014-05-01
To evaluate functional differences of the enteric nervous system (ENS) in patients between right-side colonic diverticula (RCD) and left-sided colonic diverticula (LCD), the author compared the ENS responses between RCD and LCD. Ten specimens were obtained from 10 patients with RCD, and 16 specimens were taken from 16 LCD. As a control, twenty-two specimens of right-sided normal colon (RNC) were obtained from 22 colonic cancers. Twenty-four specimens of left sided normal colon (LNC) were obtained from 24 colonic cancers. A mechanography was used to evaluate in vitro muscle responses to electrical field stimulation (EFS) before and after treatment with various autonomic nerve blockers. Before blockade of the adrenergic and cholinergic nerves, the incidences of contraction via cholinergic nerve in the colons with diverticula were significantly greater than those in the normal colons (right-sided colon; p = 0.0022, left-sided colon; p < 0.0001). There were no significant differences between RNC and LNC (p = 0.3606), and between RCD and LCD (p = 0.7684). After the blockade of adrenergic and cholinergic nerves, the incidence of relaxation via non-adrenergic non-cholinergic inhibitory (NANC) nerve in the normal colons was significantly greater than that in the diverticular colons (right-sided colon; p = 0.0435, left-sided colon; p = 0.0034). There were no significant differences between RNC and LNC (p = 0.2909) and between RCD and LCD (p = 0.9464). Cholinergic nerves were dominant in bilateral diverticular colon compared with bilateral normal colon. NANC inhibitory nerves were dominant in bilateral normal colon compared with bilateral diverticular colon. There were also no functional differences of the ENS between RCD and LCD.
Wang, Hengguang; Gu, Yifan; Wu, Yufeng; Zhang, Yi-Nan; Wang, Wei
2015-12-01
With the advances in electronics and information technology, China has gradually become the largest consumer of household appliances (HAs). Increasingly, end-of-life (EOL) HAs are generated in China. EOL recycling is a promising strategy to reduce dependence on virgin production, and indium is one of the recycled substances. The potential yield of indium recycling has not been systematically evaluated in China thus far. This paper estimates the potential yield of recycled indium from waste liquid crystal displays (LCDs) in China during the period from 2015 to 2030. The quantities of indium that will be used to produce LCDs are also predicted. The estimates focus on the following three key LCD waste sources: LCD TVs, desktop computers and portable computers. The results show that the demand for indium will be increasing in the near future. It is expected that 350 tonnes of indium will be needed to produce LCDs in China in 2035. The indium recycled from EOL LCDs, however, is much less than the demand and only accounts for approximately 48% of the indium demand. The sustainable index of indium is always less than 0.5. Therefore, future indium recycling efforts should focus on the development of recycling technology and the improvement of the relevant policy. Copyright © 2015 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-10-01
... is needed and why the aggrieved party thinks that the provision(s) of the LCD is (are) not valid... scientific evidence that support the complaint and an explanation for why the aggrieved party thinks that...
The water footprint of Austria for different diets.
Vanham, D
2013-01-01
This paper analyses the Austrian water footprint of consumption (WF(cons)) for different diets: the current diet, a healthy diet (based upon the dietary recommendations issued by the German nutrition society, or DGE), a vegetarian diet and a combined diet between both latter diets. As in many western countries, the current Austrian diet consists of too many products from the groups sugar, crop oils, meat, animal fats, milk, milk products and eggs and not enough products from the groups cereals, rice, potatoes, vegetables and fruit. Especially the consumption of animal products accounts for high WF amounts. These diets result in a substantial reduction (range 922-1,362 l per capita per day (lcd)) of the WF(cons) for agricultural products, which is currently 3,655 lcd. However, the Austrian water footprint of agricultural production (WF(prod) = 2,066 lcd) still remains lower than even the WF(cons) for a vegetarian diet (2,293 lcd). As a result the country is a net virtual water importer regarding agricultural products for all analysed scenarios.
Cell-phone based assistance for waterworks/sewage plant maintenance.
Kawada, T; Nakamichi, K; Hisano, N; Kitamura, M; Miyahara, K
2006-01-01
Cell-phones are now incorporating the functions necessary for them to be used as mobile IT devices. In this paper, we present our results of the evaluation of cell-phones as the mobile IT device to assist workers in industrial plants. We use waterworks and sewage plants as examples. By employing techniques to squeeze the SCADA screen on CRT into a small cell-phone LCD, we have made it easier for a plant's field workers to access the information needed for effective maintenance, regardless of location. An idea to link SCADA information and the plant facility information on the cell-phone is also presented. Should an accident or emergency situation arise, these cell-phone-based IT systems can efficiently deliver the latest plant information, thus the worker out in the field can respond to and resolve the emergency.
Automated hydroponics nutrition plants systems using arduino uno microcontroller based on android
NASA Astrophysics Data System (ADS)
Sihombing, P.; Karina, N. A.; Tarigan, J. T.; Syarif, M. I.
2018-03-01
Technological developments today make the combination of science is very common, including in Computer Science and Agriculture to make both of science need each other. This paper aims to develop a control tool for the flow of nutrients of hydroponic plants automatically using Arduino microcontroller and controlled by smartphone. We use an Arduino Uno microcontroller to automatically control the flow of nutrient solution with logic if else. The microcontroller can also send data of fluid level (solution) and temperature around the plant to smartphone android of the owner of the hydroponics plant. The height of the nutrient solution (water) is detected by the Ultrasonic sensor HC-SR04 and the temperature is detected by the temperature sensor LM35. Data from the sensor will forward into Arduino Uno and displayed in liquid crystal display (LCD) then via wireless fidelity (WIFI) ESP8266 module will transmit the height of the nutrient solution and the temperature around of the plants to Android smartphone.
A mobile phone-based ECG monitoring system.
Iwamoto, Junichi; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Allen W; Caldwell, W Morton
2006-01-01
We have developed a telemedicine system for monitoring a patient's electrocardiogram during daily activities. The recording system consists of three ECG chest electrodes, a variable gain instrumentation amplifier, a low power 8-bit single-chip microcomputer, a 256 KB EEPROM and a 2.4 GHz low transmitting power mobile phone (PHS). The complete system is mounted on a single, lightweight, chest electrode array. When a heart discomfort is felt, the patient pushes the data transmission switch on the recording system. The system sends the recorded ECG waveforms of the two prior minutes and ECG waveforms of the two minutes after the switch is pressed, directly in the hospital server computer via the PHS. The server computer sends the data to the physician on call. The data is displayed on the doctor's Java mobile phone LCD (Liquid Crystal Display), so he or she can monitor the ECG regardless of their location. The developed ECG monitoring system is not only applicable to at-home patients, but should also be useful for monitoring hospital patients.
NASA Astrophysics Data System (ADS)
Eichenlaub, Jesse B.
1998-04-01
At the 1997 conference DTI first reported on a low cost, thin, lightweight backlight for LCDs that generates a special illumination pattern to create autostereoscopic 3D images and can switch to conventional diffuse illumination for 2D images. The backlight is thin and efficient enough for use in portable computer and hand held games, as well as thin desktop displays. The system has been embodied in 5' (13 cm) diagonal backlights for gambling machines, and in the 12.1' (31 cm) diagonal DTI Virtual Window(TM) desktop product. During the past year, DTI has improved the technology considerably, reducing crosstalk, increasing efficiency, improving components for mass production, and developing prototypes that move the 3D viewing zones in response to the observer's head position. The paper will describe the 2D/3D backlights, improvements that have been made to their function, and their embodiments within the latest display products and prototypes.
Lim, Tae Ho; Choi, Hyuk Joong; Kang, Bo Seung
2010-01-01
We assessed the feasibility of using a camcorder mobile phone for teleconsulting about cardiac echocardiography. The diagnostic performance of evaluating left ventricle (LV) systolic function was measured by three emergency medicine physicians. A total of 138 short echocardiography video sequences (from 70 subjects) was selected from previous emergency room ultrasound examinations. The measurement of LV ejection fraction based on the transmitted video displayed on a mobile phone was compared with the original video displayed on the LCD monitor of the ultrasound machine. The image quality was evaluated using the double stimulation impairment scale (DSIS). All observers showed high sensitivity. There was an improvement in specificity with the observer's increasing experience of cardiac ultrasound. Although the image quality of video on the mobile phone was lower than that of the original, a receiver operating characteristic (ROC) analysis indicated that there was no significant difference in diagnostic performance. Immediate basic teleconsulting of echocardiography movies is possible using current commercially-available mobile phone systems.
Augmenting Plasticity Induction in Human Motor Cortex by Disinhibition Stimulation.
Cash, Robin F H; Murakami, Takenobu; Chen, Robert; Thickbroom, Gary W; Ziemann, Ulf
2016-01-01
Cellular studies showed that disinhibition, evoked pharmacologically or by a suitably timed priming stimulus, can augment long-term plasticity (LTP) induction. We demonstrated previously that transcranial magnetic stimulation evokes a period of presumably GABA(B)ergic late cortical disinhibition (LCD) in human primary motor cortex (M1). Here, we hypothesized that, in keeping with cellular studies, LCD can augment LTP-like plasticity in humans. In Experiment 1, patterned repetitive TMS was applied to left M1, consisting of 6 trains (intertrain interval, 8 s) of 4 doublets (interpulse interval equal to individual peak I-wave facilitation, 1.3-1.5 ms) spaced by the individual peak LCD (interdoublet interval (IDI), 200-250 ms). This intervention (total of 48 pulses applied over ∼45 s) increased motor-evoked potential amplitude, a marker of corticospinal excitability, in a right hand muscle by 147% ± 4%. Control experiments showed that IDIs shorter or longer than LCD did not result in LTP-like plasticity. Experiment 2 indicated topographic specificity to the M1 hand region stimulated by TMS and duration of the LTP-like plasticity of 60 min. In conclusion, GABA(B)ergic LCD offers a powerful new approach for augmenting LTP-like plasticity induction in human cortex. We refer to this protocol as disinhibition stimulation (DIS). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Jin, Chengying; Li, Dahai; Kewei, E.; Li, Mengyang; Chen, Pengyu; Wang, Ruiyang; Xiong, Zhao
2018-06-01
In phase measuring deflectometry, two orthogonal sinusoidal fringe patterns are separately projected on the test surface and the distorted fringes reflected by the surface are recorded, each with a sequential phase shift. Then the two components of the local surface gradients are obtained by triangulation. It usually involves some complicated and time-consuming procedures (fringe projection in the orthogonal directions). In addition, the digital light devices (e.g. LCD screen and CCD camera) are not error free. There are quantization errors for each pixel of both LCD and CCD. Therefore, to avoid the complex process and improve the reliability of the phase distribution, a phase extraction algorithm with five-frame crossed fringes is presented in this paper. It is based on a least-squares iterative process. Using the proposed algorithm, phase distributions and phase shift amounts in two orthogonal directions can be simultaneously and successfully determined through an iterative procedure. Both a numerical simulation and a preliminary experiment are conducted to verify the validity and performance of this algorithm. Experimental results obtained by our method are shown, and comparisons between our experimental results and those obtained by the traditional 16-step phase-shifting algorithm and between our experimental results and those measured by the Fizeau interferometer are made.
Kirschner, Andreas; Thiede, Melanie; Rubio, Rebeca Alba; Schirmer, David; Kirchner, Thomas; Richter, Gunther H.S.; Mall, Sabine; Klar, Richard; Riddell, Stanley; Busch, Dirk H.; Krackhardt, Angela; Grunewald, Thomas G.P.; Burdach, Stefan
2016-01-01
The endochondral bone protein Chondromodulin-I (CHM1) provides oncogene addiction in Ewing sarcoma (ES). We pre-clinically tested the targetability of CHM1 by TCR transgenic, allo-restricted, peptide specific T cells to treat ES. We previously generated allo-restricted wildtype CD8+ T cells directed against the ES specific antigen CHM1319 causing specific responses against ES. However, utilization of these cells in current therapy protocols is hampered due to high complexity in production, relatively low cell numbers, and rapid T cell exhaustion. In order to provide off-the-shelf products in the future, we successfully generated HLA-A*02:01-restricted T cell receptor (TCR) transgenic T cells directed against CHM1319 by retroviral transduction. After short-term expansion a 100% purified CHM1319-TCR-transgenic T cell population expressed a CD62L+/CD45RO and CD62L+/CD45RA+ phenotype. These cells displayed specific in vitro IFNg and granzyme B release in co-culture with HLA-A*02:01+ ES cell lines expressing CHM1. When co-injected with ES cells in Rag2−/−ɣc−/− mice, CHM1-specific TCR-transgenic T cells significantly inhibited the formation of lung and liver metastases in contrast to control mice. Lungs and livers of representative mice displayed CD8+ T cell infiltration in the presence (control group treated with unspecific T cells) and in the absence (study group) of metastatic disease, respectively. Furthermore, mice receiving unspecific T cells showed signs of graft-versus-host-disease in contrast to all mice, receiving CHM1319-TCR-transgenic T cells. CHM1319 specific TCR-transgenic T cells were successfully generated causing anti-ES responses in vitro and in vivo. In the future, CHM1319-TCR-transgenic T cells may control minimal residual disease rendering donor lymphocyte infusions more efficacious and less toxic. PMID:27281613
Non-binary Colour Modulation for Display Device Based on Phase Change Materials.
Ji, Hong-Kai; Tong, Hao; Qian, Hang; Hui, Ya-Juan; Liu, Nian; Yan, Peng; Miao, Xiang-Shui
2016-12-19
A reflective-type display device based on phase change materials is attractive because of its ultrafast response time and high resolution compared with a conventional display device. This paper proposes and demonstrates a unique display device in which multicolour changing can be achieved on a single device by the selective crystallization of double layer phase change materials. The optical contrast is optimized by the availability of a variety of film thicknesses of two phase change layers. The device exhibits a low sensitivity to the angle of incidence, which is important for display and colour consistency. The non-binary colour rendering on a single device is demonstrated for the first time using optical excitation. The device shows the potential for ultrafast display applications.
Green digital signage using nanoparticle embedded narrow-gap field sequential TN-LCDs
NASA Astrophysics Data System (ADS)
Kobayashi, Shunsuke; Shiraishi, Yukihide; Sawai, Hiroya; Toshima, Naoki; Okita, Masaya; Takeuchi, Kiyofumi; Takatsu, Haruyoshi
2012-03-01
We have fabricated field sequential color (FSC)-LCDs using cells and modules of narrow-gap TN-LCDs with and without doping the nanoparticles of PCyD-ZrO2 and AF-SiO2. It is shown that the FSC-LCD exhibits a high optical efficiency of OE=4.5 that is defined as OE=[Luminance]/[W/m2]=(cd/W). This figure may provide us a good reference or to clear the Energy Star Program Version 5-3 that issues a guideline: LCD with 50 inch on the diagonal consumes the energy of 108W. Through this research it is claimed that our FSC=LCD may be a novel green digital signage.
Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics
ERIC Educational Resources Information Center
Planinsic, Gorazd; Gojkosek, Mihael
2011-01-01
Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…
NASA Technical Reports Server (NTRS)
Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor); Kolosowsky, Aleksandra (Inventor)
2006-01-01
A modular and scalable seamless tiled display apparatus includes multiple display devices, a screen, and multiple lens assemblies. Each display device is subdivided into multiple sections, and each section is configured to display a sectional image. One of the lens assemblies is optically coupled to each of the sections of each of the display devices to project the sectional image displayed on that section onto the screen. The multiple lens assemblies are configured to merge the projected sectional images to form a single tiled image. The projected sectional images may be merged on the screen by magnifying and shifting the images in an appropriate manner. The magnification and shifting of these images eliminates any visual effect on the tiled display that may result from dead-band regions defined between each pair of adjacent sections on each display device, and due to gaps between multiple display devices.
Biliary drainage after laparoscopic choledochotomy
Wei, Qi; Hu, Hong-Jie; Cai, Xiao-Yan; Li, Li-Bo; Wang, Guan-Yu
2004-01-01
AIM: Transcystic biliary decompression (TCBD) has been proposed as an alternative to T-tube placement after laparoscopic choledochotomy (LCD). This permits safe primary closure of the choledochotomy and eliminates the complications associated with T-tubes. TCBD tube has been secured by Roeder knots and transfixation, and removed later than 3 wk after surgery. We presented a modified TCBD (mTCBD) method after LCD using the ureteral catheter and the Lapro-Clip (David and Geck, Danbury, Connecticut, USA), and compared it with T-tube drainage. METHODS: Between October 2002 and June 2003, patients with choledocholithiasis undergoing LCD with mTCBD (mTCBD Group, n = 30) were retrospectively compared to those undergoing LCD with T-tube drainage (T-tube Group, n = 52) at a single institution. RESULTS: There were no significant differences in operative time and retained stones between the two groups. Patients in mTCBD group had a significantly decreased average output of bile compared with those in T-tube group (306 ± 141 vs 409 ± 243 mL/24 h, P = 0.000). Removal of drain tubes in mTCBD group was done significantly earlier than that in T-tube group (median, 5 vs 29 d, P = 0.000). No complication related to drain tubes was found in mTCBD group, and morbidity rate with the T-tube was significantly higher (11.5%), and bile leakage following T-tube removal was 5.8%. CONCLUSION: A modified TCBD after LCD is safe, effective and easy to perform. It may reduce postoperative complications, especially bile leakage. PMID:15457567
Calorie restriction and bone health in young, overweight individuals.
Redman, Leanne M; Rood, Jennifer; Anton, Stephen D; Champagne, Catherine; Smith, Steven R; Ravussin, Eric
2008-09-22
Calorie restriction (CR) is promoted to increase longevity, yet this regimen could lead to bone loss and fracture and therefore affect quality of life. Forty-six individuals were randomized to 4 groups for 6 months: (1) healthy diet (control group); (2) 25% CR from baseline energy requirements (CR group); (3) 25% energy deficit by a combination of CR and increased aerobic exercise (CR + EX group); and (4) low-calorie diet (890 kcal/d; goal, 15% weight loss) followed by weight maintenance (LCD group). Bone mineral density (total body and hip by dual-energy x-ray absorptiometry) and serum bone markers (bone-specific alkaline phosphatase, osteocalcin, cross-linked C-telopeptide of type I collagen, and cross-linked N-telopeptide of type I collagen) were measured at baseline and after 6 months. Mean +/- SE body weight was reduced by -1.0% +/- 1.1% (control), -10.4% +/- 0.9% (CR), -10.0% +/- 0.8% (CR + EX), and -13.9% +/- 0.7% (LCD). Compared with the control group, none of the groups showed any change in bone mineral density for total body or hip. Bone resorption by serum cross-linked C-telopeptide of type I collagen was increased in all 3 intervention groups, with the largest change observed in the LCD group (CR, 23% +/- 10%; CR + EX, 22% +/- 9%; and LCD, 74% +/- 16% vs control, 4% +/- 10%). Serum levels of cross-linked N-telopeptide of type I collagen were also increased in the LCD group. With regard to bone formation, bone alkaline phosphatase levels were decreased in the CR group (-23% +/- 10%) but were unchanged in the CR + EX, LCD, and control groups. Moderate CR, with or without exercise, that preserves calcium intake for 6 months leads to large changes in body composition without significant bone loss in young adults. Longer studies with assessments of bone architecture are needed to confirm that CR nutrient-dense diets have no deleterious effect on bone health. clinicaltrials.gov Identifier: NCT00099151.
Alzahrani, Yahya; Colorado, Luisa H; Pritchard, Nicola; Efron, Nathan
2017-01-01
The aim was to determine longitudinal changes in Langerhans cell density (LCD) in the human cornea and conjunctiva during asymptomatic and symptomatic contact lens wear. Twenty-five participants with contact lens-induced dry eye (CLIDE) and 35 without CLIDE (NO-CLIDE), diagnosed using a range of symptom questionnaires and objective tests (tear film break up, cotton thread tear test and corneal staining) were enrolled. The central cornea and nasal bulbar conjunctiva were examined using a Heidelberg laser scanning confocal microscope at baseline and following one, four and 24 weeks wear of daily disposable hydrogel contact lenses. Twenty-three non-contact lens-wearing controls were also examined. Langerhans cells were counted manually from randomly selected images. In the cornea, mean and standard error of the mean LCD was greater after one week of lens wear in CLIDE (55 ± 7 cells/mm 2 ) versus NO-CLIDE (43 ± 4 cells/mm 2 ) (p = 0.041) and controls (27 ± 4 cells/mm 2 ) (p < 0.001). LCD was also greater in NO-CLIDE versus controls (p = 0.010). At week 4, LCD was greater in CLIDE (41 ± 6 cells/mm 2 ) versus controls (27 ± 4 cells/mm 2 ) (p = 0.004). There were no other significant differences between groups at weeks four or 24. In the conjunctiva, LCD was greater after one week of lens wear in CLIDE (17 ± 1 cells/mm 2 ) (p = 0.003) and NO-CLIDE (17 ± 3 cells/mm 2 ) (p = 0.001) versus controls (7 ± 1 cells/mm 2 ). There were no significant differences between groups at weeks four or 24. The initial transient increase in corneal and conjunctival LCD in CLIDE (versus NO-CLIDE) suggests an inflammatory component in the aetiology of this condition. © 2016 Optometry Australia.
The spatial pattern of leaf phenology and its response to climate change in China.
Dai, Junhu; Wang, Huanjiong; Ge, Quansheng
2014-05-01
Leaf phenology has been shown to be one of the most important indicators of the effects of climate change on biological systems. Few such studies have, however, been published detailing the relationship between phenology and climate change in Asian contexts. With the aim of quantifying species' phenological responsiveness to temperature and deepening understandings of spatial patterns of phenological and climate change in China, this study analyzes the first leaf date (FLD) and the leaf coloring date (LCD) from datasets of four woody plant species, Robinia pseudoacacia, Ulmus pumila, Salix babylonica, and Melia azedarach, collected from 1963 to 2009 at 47 Chinese Phenological Observation Network (CPON) stations spread across China (from 21° to 50° N). The results of this study show that changes in temperatures in the range of 39-43 days preceding the date of FLD of these plants affected annual variations in FLD, while annual variations in temperature in the range of 71-85 days preceding LCD of these plants affected the date of LCD. Average temperature sensitivity of FLD and LCD for these plants was -3.93 to 3.30 days °C(-1) and 2.11 to 4.43 days °C⁻¹, respectively. Temperature sensitivity of FLD was found to be stronger at lower latitudes or altitude as well as in more continental climates, while the response of LCD showed no consistent pattern. Within the context of significant warming across China during the study period, FLD was found to have advanced by 5.44 days from 1960 to 2009; over the same period, LCD was found to have been delayed by 4.56 days. These findings indicate that the length of the growing season of the four plant species studied was extended by a total of 10.00 days from 1960 to 2009. They also indicate that phenological response to climate is highly heterogeneous spatially.
National Laboratory for Advanced Scientific Visualization at UNAM - Mexico
NASA Astrophysics Data System (ADS)
Manea, Marina; Constantin Manea, Vlad; Varela, Alfredo
2016-04-01
In 2015, the National Autonomous University of Mexico (UNAM) joined the family of Universities and Research Centers where advanced visualization and computing plays a key role to promote and advance missions in research, education, community outreach, as well as business-oriented consulting. This initiative provides access to a great variety of advanced hardware and software resources and offers a range of consulting services that spans a variety of areas related to scientific visualization, among which are: neuroanatomy, embryonic development, genome related studies, geosciences, geography, physics and mathematics related disciplines. The National Laboratory for Advanced Scientific Visualization delivers services through three main infrastructure environments: the 3D fully immersive display system Cave, the high resolution parallel visualization system Powerwall, the high resolution spherical displays Earth Simulator. The entire visualization infrastructure is interconnected to a high-performance-computing-cluster (HPCC) called ADA in honor to Ada Lovelace, considered to be the first computer programmer. The Cave is an extra large 3.6m wide room with projected images on the front, left and right, as well as floor walls. Specialized crystal eyes LCD-shutter glasses provide a strong stereo depth perception, and a variety of tracking devices allow software to track the position of a user's hand, head and wand. The Powerwall is designed to bring large amounts of complex data together through parallel computing for team interaction and collaboration. This system is composed by 24 (6x4) high-resolution ultra-thin (2 mm) bezel monitors connected to a high-performance GPU cluster. The Earth Simulator is a large (60") high-resolution spherical display used for global-scale data visualization like geophysical, meteorological, climate and ecology data. The HPCC-ADA, is a 1000+ computing core system, which offers parallel computing resources to applications that requires large quantity of memory as well as large and fast parallel storage systems. The entire system temperature is controlled by an energy and space efficient cooling solution, based on large rear door liquid cooled heat exchangers. This state-of-the-art infrastructure will boost research activities in the region, offer a powerful scientific tool for teaching at undergraduate and graduate levels, and enhance association and cooperation with business-oriented organizations.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-27
... Frames and Image Display Devices and Components Thereof; Notice of Institution of Investigation... United States after importation of certain digital photo frames and image display devices and components... certain digital photo frames and image display devices and components thereof that infringe one or more of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... Image Display Devices and Components Thereof; Issuance of a Limited Exclusion Order and Cease and Desist... within the United States after importation of certain digital photo frames and image display devices and...: (1) The unlicensed entry of digital photo frames and image display devices and components thereof...
Analysis of roll-stamped light guide plate fabricated with laser-ablated stamper
NASA Astrophysics Data System (ADS)
Na, Hyunjun; Hong, Seokkwan; Kim, Jongsun; Hwang, Jeongho; Joo, Byungyun; Yoon, Kyunghwan; Kang, Jeongjin
2017-12-01
LGP (light guide plate) is one of the major components of LCD (liquid crystal display), and it makes surface illumination for LCD backlit. LGP is a transparent plastic plate usually produced by injection molding process. On the back of LGP there are micron size patterns for extraction of light. Recently a roll-stamping process has achieved the high mass productivity of thinner LGPs. In order to fabricate optical patterns on LGPs, a fabricating tool called as a stamper is used. Micro patterns on metallic stampers are made by several micro machining processes such as chemical etching, LIGA-reflow, and laser ablation. In this study, a roll-stamping process by using a laser ablated metallic stamper was dealt with in consideration of the compatibility with the roll-stamping process. LGP fabricating tests were performed using a roll-stamping process with four different roll pressures. Pattern shapes on the stamper fabricated by laser ablation and transcription ratios of the roll-stamping process were analyzed, and LGP luminance was evaluated. Based on the evaluation, optical simulation model for LGP was made and simulation accuracy was evaluated. Simulation results showed good agreements with optical performance of LGPs in the brightness and uniformity. It was also shown that the roll-stamped LGP has the possibility of better optical performance than the conventional injection molded LGP. It was also shown that the roll-stamped LGP with the laser ablated stamper is potential to have better optical performance than the conventional injection molded LGP.
Study on dynamic deformation synchronized measurement technology of double-layer liquid surfaces
NASA Astrophysics Data System (ADS)
Tang, Huiying; Dong, Huimin; Liu, Zhanwei
2017-11-01
Accurate measurement of the dynamic deformation of double-layer liquid surfaces plays an important role in many fields, such as fluid mechanics, biomechanics, petrochemical industry and aerospace engineering. It is difficult to measure dynamic deformation of double-layer liquid surfaces synchronously for traditional methods. In this paper, a novel and effective method for full-field static and dynamic deformation measurement of double-layer liquid surfaces has been developed, that is wavefront distortion of double-wavelength transmission light with geometric phase analysis (GPA) method. Double wavelength lattice patterns used here are produced by two techniques, one is by double wavelength laser, and the other is by liquid crystal display (LCD). The techniques combine the characteristics such as high transparency, low reflectivity and fluidity of liquid. Two color lattice patterns produced by laser and LCD were adjusted at a certain angle through the tested double-layer liquid surfaces simultaneously. On the basis of the refractive indexes difference of two transmitted lights, the double-layer liquid surfaces were decoupled with GPA method. Combined with the derived relationship between phase variation of transmission-lattice patterns and out-of plane heights of two surfaces, as well as considering the height curves of the liquid level, the double-layer liquid surfaces can be reconstructed successfully. Compared with the traditional measurement method, the developed method not only has the common advantages of the optical measurement methods, such as high-precision, full-field and non-contact, but also simple, low cost and easy to set up.
Image Quality Characteristics of Handheld Display Devices for Medical Imaging
Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo
2013-01-01
Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113
The performance of quantum dots-based white light-emitting diodes
NASA Astrophysics Data System (ADS)
Chen, Kuan-Lin; Chung, Shu-Ru
2017-08-01
Recently, the investigation of quantum dots (QDs) as a color converter for white light-emitting diodes (WLEDs) application has attracted a great deal of attention. Because the narrow emission wavelength of QDs can be controlled by their particle sizes and compositions, which is facilitated to improve the color gamut of display as well as color rendering index (CRI) and the correlated color temperature (CCT) of WLEDs. In a typical commercially available LCD display, the color gamut is approximately to 75 % which is defined by the National Television System Committee (NTSC). In order to enhance NTSC, the full width at half-maximum (FWHM) of color converter should be less than 30 nm. Therefore, the QDs are the best choice for display application due to the FWHM of QDs is meet the demand of display application. In this study, the hot injection method with one-pot process is used to synthesis of colloidal ternary ZnCdSe green (G-) and red-emission (R-) QDs with a narrow emission wavelength around 537 and 610 nm. By controlling the complex reagents-stearic acid (SA) and lauric acid (LA), high performance of G- and R-QDs can be prepared. The quantum yields (QYs), particle sizes and FWHM for G- and R-QDs are 70, 30 %, 3.2 +/- 0.5, 4.1 +/- 0.5 nm and 25, 26 nm, respectively. In order to explore the performance of QDs-based WLEDs, mixing ratios effect between G-QD and R-QD are studied and the WLED is packed as conformal-type. Different ratios of R-QD and G-QD (1:10, 1:20 and 1:30) are mixed and fill up the 3020 SMD blue-InGaN LED, and named as LED-10, LED-20 and LED-30. After that, UV curable gel is deposited on the top of QD layer to form WLED and named as LED-10*, LED-20* and LED-30*. The results show that the Commission International d'Eclairage (CIE) chromaticity coordinates, color rendering index (CRI), luminous efficacy of LED-10*, LED-20* and LED-30* are (0.27, 0.21), 53, 1.9 lm/W, (0.29, 0.30), 72, 3.3 lm/W and (0.25, 0.34), 45, 6.8 lm/W, respectively. We can find that the positions of CIE can be controlled simply by adjusting the ratios of G- and R-QDs. Besides, the LED-10 and LED-20* device shows the high CRI, implying that it has great potential for application on backlight of display technology and solid-state lighting.
A critical review of low-carbohydrate diets in people with Type 2 diabetes.
van Wyk, H J; Davis, R E; Davies, J S
2016-02-01
The efficacy of low-carbohydrate diets (LCD) in people with Type 2 diabetes has divided the nutrition community. This review seeks to re-examine the available data to clarify understanding. A comprehensive search of databases was used to identify meta-analyses of LCD in Type 2 diabetes. To improve the quality of the studies analysed, the following inclusion criteria were applied: randomized control trials ≥ 4 weeks in people aged > 18 years with Type 2 diabetes; a carbohydrate intake ≤ 45% of total energy intake per day; and a dietary intake assessment at the end of the study. The resulting studies were subjected to a thematic analysis. Nine meta-analyses were identified containing 153 studies. Twelve studies met our amended inclusion criteria. There were no significant differences in metabolic markers, including glycaemic control, between the two diets, although weight loss with a LCD was greater in one study. Carbohydrate intake at 1 year in very LCD (< 50 g of carbohydrates) ranged from 132 to 162 g. In some studies, the difference between diets was as little as 8 g/day of carbohydrates. Total energy intake remains the dietary predictor of body weight. A LCD appears no different from a high-carbohydrate diet in terms of metabolic markers and glycaemic control. Very LCDs may not be sustainable over a medium to longer term as carbohydrate intake in diets within studies often converged toward a more moderate level. The variable quality of studies included in earlier meta-analyses likely explains the previous inconsistent findings between meta-analyses. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.
Tofangchiha, Maryam; Adel, Mamak; Bakhshi, Mahin; Esfehani, Mahsa; Nazeman, Pantea; Ghorbani Elizeyi, Mojgan; Javadi, Amir
2013-01-01
Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen's kappa. Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). The type of monitor does not influence diagnosis of vertical root fractures.
Development of 3-dimensional compact magnetic dosimeter for environmental magnetic field monitoring
NASA Astrophysics Data System (ADS)
Kubota, Yusuke; Obayashi, Haruo; Miyahara, Akira; Ohno, Kazuko; Nakamura, Kouichi; Horii, Kenzi
1991-07-01
A computer-driven, three-dimensional magnetic fluxmeter to be used for magnetic field dosimetry has been developed. A magnetic monitor applicable to this object should be measurable to an absolute value of local magnetic field strength and also be able to record its time integration as a measure of exposed dose to the magnetic field. The present fluxmeter consists of signal amplifiers, rectifiers, an A/D converter, and a pocket computer (PC). The signal outputs from the sensors are processed with the PC to compose an absolute strength of magnetic flux density and its time-integrated value. The whole system is driven by a battery and is quite compact in size to be used as a handy portable system. Further details of the design, idea, construction, specification, and testing result of the fluxmeter are described. The measurable range are from 0.4G to 20,000G in normal mode and 8mG to 400G in high-sensitivity AC mode, and the sensitivity is well independent of the magnetic field direction. These measured data are displayed in real time on the LCD panel of the PC and memorized in RAM files. Possible application of the fluxmeter is discussed with special attention to the search of the leakage and/or disturbing error fields around LHD (Large Helical Device) and other magnetic systems, the individual dose control to the workers in strong magnetic fields, and the evaluation of the effects of long irradiation of magnetic fields.
Ichihashi, Yasuyuki; Oi, Ryutaro; Senoh, Takanori; Yamamoto, Kenji; Kurita, Taiichiro
2012-09-10
We developed a real-time capture and reconstruction system for three-dimensional (3D) live scenes. In previous research, we used integral photography (IP) to capture 3D images and then generated holograms from the IP images to implement a real-time reconstruction system. In this paper, we use a 4K (3,840 × 2,160) camera to capture IP images and 8K (7,680 × 4,320) liquid crystal display (LCD) panels for the reconstruction of holograms. We investigate two methods for enlarging the 4K images that were captured by integral photography to 8K images. One of the methods increases the number of pixels of each elemental image. The other increases the number of elemental images. In addition, we developed a personal computer (PC) cluster system with graphics processing units (GPUs) for the enlargement of IP images and the generation of holograms from the IP images using fast Fourier transform (FFT). We used the Compute Unified Device Architecture (CUDA) as the development environment for the GPUs. The Fast Fourier transform is performed using the CUFFT (CUDA FFT) library. As a result, we developed an integrated system for performing all processing from the capture to the reconstruction of 3D images by using these components and successfully used this system to reconstruct a 3D live scene at 12 frames per second.
Toward high-resolution optoelectronic retinal prosthesis
NASA Astrophysics Data System (ADS)
Palanker, Daniel; Huie, Philip; Vankov, Alexander; Asher, Alon; Baccus, Steven
2005-04-01
It has been already demonstrated that electrical stimulation of retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. Current retinal implants provide very low resolution (just a few electrodes), while several thousand pixels are required for functional restoration of sight. We present a design of the optoelectronic retinal prosthetic system that can activate a retinal stimulating array with pixel density up to 2,500 pix/mm2 (geometrically corresponding to a visual acuity of 20/80), and allows for natural eye scanning rather than scanning with a head-mounted camera. The system operates similarly to "virtual reality" imaging devices used in military and medical applications. An image from a video camera is projected by a goggle-mounted infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. Such a system provides a broad field of vision by allowing for natural eye scanning. The goggles are transparent to visible light, thus allowing for simultaneous utilization of remaining natural vision along with prosthetic stimulation. Optical control of the implant allows for simple adjustment of image processing algorithms and for learning. A major prerequisite for high resolution stimulation is the proximity of neural cells to the stimulation sites. This can be achieved with sub-retinal implants constructed in a manner that directs migration of retinal cells to target areas. Two basic implant geometries are described: perforated membranes and protruding electrode arrays. Possibility of the tactile neural stimulation is also examined.
[Changes in various indicators of orthostatic stability in humans on long-term low-caloric diets].
Tsyganov, E P; Kolchin, E V; Dupik, V S
1984-01-01
Ten male volunteers received a low-caloric diet (LCD) (under 1200 kcal) containing 49.4 g protein, 28 g fat and 181 g carbohydrates for 3 weeks, with energy expenditure amounting to about 2900 kcal/day. During the time indicated, the body mass of the test subjects dropped by 7.1%. According to subjective data the well-being, physical and mental working ability remained unchanged in the test subjects. During feeding with the LCD and making the active orthostatic test, the increment of the heart rate upon the change of the body position appeared the same as that during the comparison period. Meanwhile on the 6th day of the recovery period the increment was significantly higher than at the comparison period. The systolic, pulse and mean arterial pressure, with the test subjects fed the LCD being in the vertical position and at the recovery period, was lower than at the comparison period. The data obtained attest to a definite lowering of the orthostatic stability of man kept on the LCD for a long time and at the recovery period, with this lowering taking place chiefly at the expense of changes in the tone of peripheral blood vessels.
Flexible Display and Integrated Communication Devices (FDICD) Technology. Volume 2
2008-06-01
AFRL-RH-WP-TR-2008-0072 Flexible Display and Integrated Communication Devices (FDICD) Technology, Volume II David Huffman Keith Tognoni...14 April 2004 – 20 June 2008 4. TITLE AND SUBTITLE Flexible Display and Integrated Communication Devices (FDICD) Technology, Volume II 5a...14. ABSTRACT This flexible display and integrated communication devices (FDICD) technology program sought to create a family of powerful
Oh, Ji-Hoon; Kwak, Seung-Yeon; Yang, Seung-Cheol; Bae, Byeong-Soo
2010-03-01
Photocurable and highly condensed fluorinated methacrylate oligosiloxane, with a low dielectric constant (kappa = 2.54), was prepared by a nonhydrolytic sol-gel condensation reaction. The oligosiloxane resin was then spin-coated, photocured, and thermally baked in order to fabricate a fluorinated methacrylate hybrid material (FM hybrimer) thin film. This study investigated the application of this FM hybrimer film as a low-kappa passivation layer in LCD-based thin film transistors (TFT). It was found that a dielectric constant as low as kappa = 2.54 could be obtained, without introducing pores in the dense FM hybrimer films. This study compares FM hybrimer film characteristics with those required for passivation layers in LCD-TFTs, including thermal stability, optical transmittance, hydrophobicity, gap fill, and planarization effects as well as electrical insulation.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-23
... INTERNATIONAL TRADE COMMISSION [DN 2858] Certain Consumer Electronics and Display Devices and.... International Trade Commission has received a complaint entitled In Re Certain Consumer Electronics and Display... importation of certain consumer electronics and display devices and products containing same. The complaint...