Sample records for display rate meter

  1. The Seven-Segment Data Logger

    NASA Astrophysics Data System (ADS)

    Bates, Alan

    2015-12-01

    Instruments or digital meters with data values visible on a seven-segment display can easily be found in the physics lab. Examples include multimeters, sound level meters, Geiger-Müller counters and electromagnetic field meters, where the display is used to show numerical data. Such instruments, without the ability to connect to computers or data loggers, can measure and display data at a particular instant in time. The user should be present to read the display and to record the data. Unlike these digital meters, the sensor-data logger system has the advantage of automatically measuring and recording data at selectable sample rates over a desired sample time. The process of adding data logging features to a digital meter with a seven-segment display can be achieved with Seven Segment Optical Character Recognition (SSOCR) software. One might ask, why not just purchase a field meter with data logging features? They are relatively inexpensive, reliable, available online, and can be delivered within a few days. But then there is the challenge of making your own instrument, the excitement of implementing a design, the pleasure of experiencing an entire process from concept to product, and the satisfaction of avoiding costs by taking advantage of available technology. This experiment makes use of an electromagnetic field meter with a seven-segment liquid crystal display to measure background electromagnetic field intensity. Images of the meter display are automatically captured with a camera and analyzed using SSOCR to produce a text file containing meter display values.

  2. Arduino based radiation survey meter

    NASA Astrophysics Data System (ADS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Muzakkir, Amir; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr-1). Conversion factor (CF) value for conversion of CPM to μSvhr-1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  3. Aircraft control position indicator

    NASA Technical Reports Server (NTRS)

    Dennis, Dale V. (Inventor)

    1987-01-01

    An aircraft control position indicator was provided that displayed the degree of deflection of the primary flight control surfaces and the manner in which the aircraft responded. The display included a vertical elevator dot/bar graph meter display for indication whether the aircraft will pitch up or down, a horizontal aileron dot/bar graph meter display for indicating whether the aircraft will roll to the left or to the right, and a horizontal dot/bar graph meter display for indicating whether the aircraft will turn left or right. The vertical and horizontal display or displays intersect to form an up/down, left/right type display. Internal electronic display driver means received signals from transducers measuring the control surface deflections and determined the position of the meter indicators on each dot/bar graph meter display. The device allows readability at a glance, easy visual perception in sunlight or shade, near-zero lag in displaying flight control position, and is not affected by gravitational or centrifugal forces.

  4. Dead-time compensation for a logarithmic display rate meter

    DOEpatents

    Larson, John A.; Krueger, Frederick P.

    1988-09-20

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

  5. Dead-time compensation for a logarithmic display rate meter

    DOEpatents

    Larson, J.A.; Krueger, F.P.

    1987-10-05

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events. 5 figs.

  6. Automatic remote-integration metering center. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Philippidis, P.A.; Weinreb, M.; de Gil, B.F.

    1988-11-01

    The report documents a multi-phase program for the development and demonstration of a unique automatic and remote metering system. The system consists of a solid-state meter module to provide electrical consumption data, tamper detection, and load control functions; a central master station to interrogate the meter modules for their data and also to transmit load control signals; and a data display module to be accessible to tenants wishing to obtain their meter readings. The system has the capability to measure and allocate demand and to process time of use rates. It also has a meter accuracy self-test feature. The systemmore » is suitable for both direct metering of multi-family buildings and the sub-metering of master-metered apartment buildings. In addition to describing the system, the report documents the results of a 371-point field trial at Scott Tower, a cooperative apartment building in the Bronx, New York.« less

  7. State-of-charge coulometer

    NASA Technical Reports Server (NTRS)

    Rowlette, J. J. (Inventor)

    1985-01-01

    A coulometer for accurately measuring the state-of-charge of an open-cell battery utilizing an aqueous electrolyte, includes a current meter for measuring the battery/discharge current and a flow meter for measuring the rate at which the battery produces gas during charge and discharge. Coupled to the flow meter is gas analyzer which measures the oxygen fraction of the battery gas. The outputs of the current meter, flow meter, and gas analyzer are coupled to a programmed microcomputer which includes a CPU and program and data memories. The microcomputer calculates that fraction of charge and discharge current consumed in the generation of gas so that the actual state-of-charge can be determined. The state-of-charge is then shown on a visual display.

  8. Constancy of built-in luminance meter measurements in diagnostic displays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M.

    2013-12-15

    Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49 336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25 000 BLH and those with more than 25 000 BLH. Bias between meters was also evaluated.more » Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35 000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25 000 and greater than 25 000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35 000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The surveymore » meter measurement results are found to be linear for dose rates below 3500 µSv/hr.« less

  10. BAT3 Analyzer: Real-Time Data Display and Interpretation Software for the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3)

    USGS Publications Warehouse

    Winston, Richard B.; Shapiro, Allen M.

    2007-01-01

    The BAT3 Analyzer provides real-time display and interpretation of fluid pressure responses and flow rates measured during geochemical sampling, hydraulic testing, or tracer testing conducted with the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3) (Shapiro, 2007). Real-time display of the data collected with the Multifunction BAT3 allows the user to ensure that the downhole apparatus is operating properly, and that test procedures can be modified to correct for unanticipated hydraulic responses during testing. The BAT3 Analyzer can apply calibrations to the pressure transducer and flow meter data to display physically meaningful values. Plots of the time-varying data can be formatted for a specified time interval, and either saved to files, or printed. Libraries of calibrations for the pressure transducers and flow meters can be created, updated and reloaded to facilitate the rapid set up of the software to display data collected during testing with the Multifunction BAT3. The BAT3 Analyzer also has the functionality to estimate calibrations for pressure transducers and flow meters using data collected with the Multifunction BAT3 in conjunction with corroborating check measurements. During testing with the Multifunction BAT3, and also after testing has been completed, hydraulic properties of the test interval can be estimated by comparing fluid pressure responses with model results; a variety of hydrogeologic conceptual models of the formation are available for interpreting fluid-withdrawal, fluid-injection, and slug tests.

  11. The Seven-Segment Data Logger

    ERIC Educational Resources Information Center

    Bates, Alan

    2015-01-01

    Instruments or digital meters with data values visible on a seven-segment display can easily be found in the physics lab. Examples include multimeters, sound level meters, Geiger-Müller counters and electromagnetic field meters, where the display is used to show numerical data. Such instruments, without the ability to connect to computers or data…

  12. Steps Towards the Integration of Conflict Resolution with Metering and Scheduling

    NASA Technical Reports Server (NTRS)

    McNally, B. David; Edwards, Thomas (Technical Monitor)

    1998-01-01

    NASA Ames Research Center is developing decision support tool technology for air traffic controllers to improve the efficiency and capacity of National Airspace System. The goal is to provide technology, tools and procedures that result in the highest possible level of user preferred trajectories whenever possible with safe and efficient traffic management when necessary. The work is being conducted under the NASA Advanced Air Transportation Technology Program in cooperation with the FAA through the Inter-Agency Integrated Product Team. The objective is to develop technology and procedures that lead towards a seamless integration of conflict resolution with metering and scheduling for arrival aircraft and en route aircraft that are under metering restrictions. A requirement is that the integration incorporate user preferred trajectories. The ultimate goal is the implementation and validation of the Descent Advisor (DA) concept which provides clearance advisories to a sector controller that simultaneously meet metering constraints, are conflict free, incorporate a user preferred (e.g., minimum fuel) descent profile, and generally require no further corrective clearance as the aircraft transitions from en route cruise into the TRACON. The DA concept may also be applied to en route aircraft under metering constraints, e.g., miles-in-trail. To achieve the DA concept a stepwise development and field evaluation is anticipated. This paper addresses the initial steps towards implementation of the DA. The Traffic Management Advisor (TMA) computes arrival time sequence and required delay information for display to the sector controller during periods when arrivals must be metered due to landing rate restrictions at the airport. The Initial Conflict Probe (ICP) compares trajectory predictions for all aircraft and alerts the controller when any two aircraft are predicted to violate separation standards (5 mi. and 2000 ft. in en route airspace). ICP also includes a trial planning function allowing the controller to develop and check a separate "what if" trajectory for conflict resolution. TMA and ICP currently operate independent of one another and have separate controller displays. The TMA meter list is on the radar controller's plan view display. The ICP is still under development, but the current concept calls for a list of predicted conflicts at the data controller position. The research described herein address two steps towards the implementation of DA. The first is to develop a concept for integrated display of conflict and metering information on a controller's display. The objective is to provide the controller with situational awareness of one problem while he develops a solution to the other. The next step is to expand the concept for display of automated clearance advisories for one problem (e.g., metering) which take into account the other problems (e.g., conflicts). Information to be communicated between TMA and ICP to facilitate' manual or automated advisories is being identified as the concept matures. In order to study the ICP/TMA integration concept the CTAS conflict probe capability has been adapted to Ft. Worth Center. The system is being validated in the laboratory with all-track data and for non -interference with TMA, TMA is already running as a daily use prototype at Ft. Worth Center. A laboratory prototype system has been developed under the CTAS baseline which combines conflict and metering information on a common user interface. Elements of the user interface are shown in Figure 1. In this simple illustration the user sees the simultaneous effect of a trial plan on meter fix delay and conflict status. Delay information is shown in the aircraft flight data block, the meter list, and the TMA timeline. Experience during Descent Advisor development and observations at Ft. Worth Center high and low attitude arrival sectors during metering suggests that manual trial planning will be unworkable during rush periods due to high controller workload.

  13. Aerial radiological survey of the Salem Nuclear Generating Station and surrounding area, Salem, New Jersey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feimster, E.L.

    An aerial radiological survey was performed from 24 July through 1 August 1980 over a 244-square-kilometer (95-square-mile) area centered on the Salem Nuclear Generating Station near Salem, New Jersey. All gamma ray data were collected by flying lines oriented north-south and spaced 152 meters (500 feet) apart, at an altitude of 91 meters (300 feet) above the ground. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters except directly over the site, where spectral analysis revealed the presence of /sup 60/Co. Count rates obtained from the aerial platformmore » were converted to exposure rates at 1 meter above the ground and are presented in the form of an exposure rate contour map. The resulting exposure rates varied between 5 and 55 microroentgens per hour (..mu..R/h). The river-shore areas ranged from 5 to 7 ..mu..R/h, inland areas showed 7 to 12 ..mu..R/h, and the site had a maximum exposure rate of 55 ..mu..R/h. These values include an estimated cosmic ray contribution of 4 ..mu..R/h. The exposure rates obtained from soil samples taken within the survey area displayed good agreement with the aerial data.« less

  14. Arrival Metering Precision Study

    NASA Technical Reports Server (NTRS)

    Prevot, Thomas; Mercer, Joey; Homola, Jeffrey; Hunt, Sarah; Gomez, Ashley; Bienert, Nancy; Omar, Faisal; Kraut, Joshua; Brasil, Connie; Wu, Minghong, G.

    2015-01-01

    This paper describes the background, method and results of the Arrival Metering Precision Study (AMPS) conducted in the Airspace Operations Laboratory at NASA Ames Research Center in May 2014. The simulation study measured delivery accuracy, flight efficiency, controller workload, and acceptability of time-based metering operations to a meter fix at the terminal area boundary for different resolution levels of metering delay times displayed to the air traffic controllers and different levels of airspeed information made available to the Time-Based Flow Management (TBFM) system computing the delay. The results show that the resolution of the delay countdown timer (DCT) on the controllers display has a significant impact on the delivery accuracy at the meter fix. Using the 10 seconds rounded and 1 minute rounded DCT resolutions resulted in more accurate delivery than 1 minute truncated and were preferred by the controllers. Using the speeds the controllers entered into the fourth line of the data tag to update the delay computation in TBFM in high and low altitude sectors increased air traffic control efficiency and reduced fuel burn for arriving aircraft during time based metering.

  15. Design and implementation of Remote Digital Energy Meter (RDEM) based on GSM technology

    NASA Astrophysics Data System (ADS)

    Khan, Muhammad Waseem; Wang, Jie; Irfan, Muhammad; Shiraz, M.; Khan, Ali Hassan

    2017-11-01

    Electric power is one of the basic requirement for socio economic and social prosperity of any country, which is mainly employs for domestic, industrial and agricultural sectors. The primary purpose of this research is to design and implement an energy meter which can remotely control and monitor through global system for mobile (GSM) communication technology. For this purpose, a single phase or three phase digital energy meters are used to add on different advanced modules. The energy meter can be activated and display power consumption information at the consumer premises on liquid crystal display and through a short message service (SMS) by using GSM technology. At the power sending end, an energy meter can be remotely control and monitor through GSM technology without any system disturbances. This study will lead to make the system easier, economical, reliable and efficient for the electrical department.

  16. Testing of YUH-61A helicopter transmission in NASA Lewis 2240-kW (3000-hp facility

    NASA Technical Reports Server (NTRS)

    Mitchell, A. M.; Oswald, F. B.; Schuller, F. T.

    1986-01-01

    A helicopter transmission that was being considered for the Army's Utility Tactical Transport Attack System (UTTAS) was tested in the NASA Lewis 2240-kW (3000-hp) test facility to obtain the transmission's operational data. The results will form a vibration and efficiency data base for evaluation similar-class helicopter transmissions. The transmission's mechanical efficiency was determined to be 98.7 percent at its rated power level of 2080 kW (2792 hp). At power levels up to 113 percent of rated the transmission displayed 56 percent higher vibration acceleration levels on the right input than on the left input. Both vibration signature analysis and final visual inspection indicated that the right input spiral-bevel gear had poor contact patterns. The highest vibration meter level was 52 g's rms at the accessory gear, which had free-wheeling gearsets. At 113 percent power and 100 percent rated speed the vibration meter levels generally ranged from 3 to 25 g's rms.

  17. Quantitative measuring system for combustible gas with audible tick rate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batz, J.E.

    1979-09-04

    Northern Illinois Gas Co.'s new gas-detection instrument is lightweight, portable, easy to use, and in compliance with industry standards as an intrinsically safe device. The instrument uses a semiconductor gas-sensor element energyzed with the regulated voltage source. Placed in the atmosphere to be tested, the detector generates a signal representative of the concentration of natural gas in the air. A meter displays the signal to determine whether the area is hazardous; a variable-repetition-rate blocking oscillator feeding a speaker responds to the signal, generating an audible tick rate useful in locating a leak.

  18. Automatic ranging circuit for a digital panel meter

    DOEpatents

    Mueller, Theodore R.; Ross, Harley H.

    1976-01-01

    This invention relates to a range changing circuit that operates in conjunction with a digital panel meter of fixed sensitivity. The circuit decodes the output of the panel meter and uses that information to change the gain of an input amplifier to the panel meter in order to insure that the maximum number of significant figures is always displayed in the meter. The circuit monitors five conditions in the meter and responds to any of four combinations of these conditions by means of logic elements to carry out the function of the circuit.

  19. East Europe Report. Economic and Industrial Affairs No. 2437.

    DTIC Science & Technology

    1983-08-17

    considerable attention at exhibitions in Hungary, including also the Budapest International Fair. The showroom that opened this year on Ors Vezer Square...quickly became popular. One reason for this is the display of Soviet cars. What role do you intend to assign the showroom in the future, and what...exhibitions will be held there? [Answer] The showroom for displaying Soviet commodities features 450 square meters of floorspace and 600 square meters of

  20. Plant Gas Exchange at High Wind Speeds 1

    PubMed Central

    Caldwell, Martyn M.

    1970-01-01

    High altitude Rhododendron ferrugineum L. and Pinus cembra L. seedlings were exposed to winds at 15 meters per second for 24-hour periods. Wind-sensitive stomata of Rhododendron seedlings immediately initiated a closing response which resulted in decreased photosynthesis and an even greater reduction in transpiration. Stomatal aperture and transpiration rates of P. cembra were only slightly reduced by high speed winds. However, photosynthesis was substantially reduced because of changes in needle display to available irradiation. PMID:16657501

  1. Price current-meter standard rating development by the U.S. geological survey

    USGS Publications Warehouse

    Hubbard, E.F.; Schwarz, G.E.; Thibodeaux, K.G.; Turcios, L.M.

    2001-01-01

    The U.S. Geological Survey has developed new standard rating tables for use with Price type AA and pygmy current meters, which are employed to measure streamflow velocity. Current-meter calibration data, consisting of the rates of rotation of meters at several different constant water velocities, have shown that the original rating tables are no longer representative of the average responsiveness of newly purchased meters or meters in the field. The new rating tables are based on linear regression equations that are weighted to reflect the population mix of current meters in the field and weighted inversely to the variability of the data at each calibration velocity. For calibration velocities of 0.3 m/s and faster, at which most streamflow measurements are made, the new AA-rating predicts the true velocities within 1.5% and the new pygmy-meter rating within 2.0% for more than 95% of the meters. At calibration velocities, the new AA-meter rating is up to 1.4% different from the original rating, and the new pygmy-meter rating is up to 1.6% different.

  2. The design and application of virtual ion meter based on LABVIEW 8.0.

    PubMed

    Meng, Hu; Li, Jiangyuan; Tang, Yonghuai

    2009-08-01

    The virtual ion meter is developed based on LABVIEW 8.0 by homemade adjusting circuit, data acquisition (DAQ) board, and computer. This note provides details of the structure of testing system and flow chart of DAQ program. This virtual instrument system is applied to multitask testing such as determining rate constant of second-order reaction by pX, pX potentiometric titration, determining oscillating reaction by potential, etc. The result of application indicates that this test system not only has function of real-time data acquiring, displaying, storage, but also realizes remote monitoring and controlling test-control spots through internet, automatic analyzing and processing of data, reporting of result according to the different testing task; moreover, the veracity and repeatability of data processing result are higher than the results of manual data processing.

  3. Design of an Open Smart Energy Gateway for Smart Meter Data Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Page, Janie; McParland, Chuck; Piette, Mary Ann

    With the widespread deployment of electronic interval meters, commonly known as smart meters, came the promise of real-time data on electric energy consumption. Recognizing an opportunity to provide consumers access to their near real-time energy consumption data directly from their installed smart meter, we designed a mechanism for capturing those data for consumer use via an open smart energy gateway (OpenSEG). By design, OpenSEG provides a clearly defined boundary for equipment and data ownership. OpenSEG is an open-source data management platform to enable better data management of smart meter data. Effectively, it is an information architecture designed to work withmore » the ZigBee Smart Energy Profile 1.x (SEP 1.x). It was specifically designed to reduce cyber-security risks and provide secure information directly from smart meters to consumers in near real time, using display devices already owned by the consumers. OpenSEG stores 48 hours of recent consumption data in a circular cache using a format consistent with commonly available archived (not real-time) consumption data such as Green Button, which is based on the Energy Services Provider Interface (ESPI) data standard. It consists of a common XML format for energy usage information and a data exchange protocol to facilitate automated data transfer upon utility customer authorization. Included in the design is an application program interface by which users can acquire data from OpenSEG for further post processing. A sample data display application is included in the initial software product. The data display application demonstrates that OpenSEG can help electricity use data to be retrieved from a smart meter and ported to a wide variety of user-owned devices such as cell phones or a user-selected database. This system can be used for homes, multi-family buildings, or small commercial buildings in California.« less

  4. Fission Meter Information Barrier Attribute Measurement System: Task 1 Report: Document existing Fission Meter neutron IB system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerr, P. L.

    An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements inmore » a way the does not reveal sensitive information. In full IB mode, only red/green ‘lights’ are displayed in the software. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.« less

  5. The utility of blood glucose meters in biotechnological applications.

    PubMed

    FitzGerald, Jennifer; Vermerris, Wilfred

    2005-06-01

    Most methods used to measure glucose concentrations in biotechnological settings are labour-intensive and/or expensive. With this in mind we have investigated the possibility of employing blood glucose meters, the use of which has the benefit of being fast, convenient and inexpensive, for this purpose. Accu-Chek Advantage (Roche Diagnostics, Indianapolis, IN, U.S.A.) and Precision QID (Medisense, Abbott Laboratories, Indianapolis, IN, U.S.A.) meters were tested using glucose samples of known concentration, at pH 7.5 and 4.8. The Accu-Chek Advantage meter uses strips containing the enzyme glucose dehydrogenase. This meter showed a linear response for glucose concentrations between 0.50 and 6.0 g/litre, and the effect of pH was small. The Precision QID meter uses strips containing the enzyme glucose oxidase and is more sensitive to pH. The displayed glucose concentrations at low pH values were consistently lower than at higher pH values. At both pH values the response curve reached a plateau, which limited the effective range of this meter to a range of 0.30-2.5 g/litre. Unlike the Precision QID meter, the Accu-Chek Advantage meter also responded to xylose and arabinose. A synergistic effect of combining sugars was observed when a mixture of sugars consisting of glucose and arabinose, or glucose and xylose, was applied: the displayed concentrations were consistently higher than was expected on the basis of the individual calibration curves. The use of glucose meters is a fast and convenient alternative to existing methods and may be of particular use for screening purposes where a high degree of accuracy is not crucial. The choice of meter should depend on the application, and in this respect the pH, expected concentration range and the presence of other sugars are among the factors that should be considered.

  6. Study of Fourier transform spectrometer based on Michelson interferometer wave-meter

    NASA Astrophysics Data System (ADS)

    Peng, Yuexiang; Wang, Liqiang; Lin, Li

    2008-03-01

    A wave-meter based on Michelson interferometer consists of a reference and a measurement channel. The voice-coiled motor using PID means can realize to move in stable motion. The wavelength of a measurement laser can be obtained by counting interference fringes of reference and measurement laser. Reference laser with frequency stabilization creates a cosine interferogram signal whose frequency is proportional to velocity of the moving motor. The interferogram of the reference laser is converted to pulse signal, and it is subdivided into 16 times. In order to get optical spectrum, the analog signal of measurement channel should be collected. The Analog-to-Digital Converter (ADC) for measurement channel is triggered by the 16-times pulse signal of reference laser. So the sampling rate is constant only depending on frequency of reference laser and irrelative to the motor velocity. This means the sampling rate of measurement channel signals is on a uniform time-scale. The optical spectrum of measurement channel can be processed with Fast Fourier Transform (FFT) method by DSP and displayed on LCD.

  7. The Effects of Synthetic and Enhanced Vision Technologies for Lunar Landings

    NASA Technical Reports Server (NTRS)

    Kramer, Lynda J.; Norman, Robert M.; Prinzel, Lawrence J., III; Bailey, Randall E.; Arthur, Jarvis J., III; Shelton, Kevin J.; Williams, Steven P.

    2009-01-01

    Eight pilots participated as test subjects in a fixed-based simulation experiment to evaluate advanced vision display technologies such as Enhanced Vision (EV) and Synthetic Vision (SV) for providing terrain imagery on flight displays in a Lunar Lander Vehicle. Subjects were asked to fly 20 approaches to the Apollo 15 lunar landing site with four different display concepts - Baseline (symbology only with no terrain imagery), EV only (terrain imagery from Forward Looking Infra Red, or FLIR, and LIght Detection and Ranging, or LIDAR, sensors), SV only (terrain imagery from onboard database), and Fused EV and SV concepts. As expected, manual landing performance was excellent (within a meter of landing site center) and not affected by the inclusion of EV or SV terrain imagery on the Lunar Lander flight displays. Subjective ratings revealed significant situation awareness improvements with the concepts employing EV and/or SV terrain imagery compared to the Baseline condition that had no terrain imagery. In addition, display concepts employing EV imagery (compared to the SV and Baseline concepts which had none) were significantly better for pilot detection of intentional but unannounced navigation failures since this imagery provided an intuitive and obvious visual methodology to monitor the validity of the navigation solution.

  8. SU-G-IeP3-01: Better Kerma-Area-Product (KAP) Estimation Using the System Parameters in Radiography and Fluoroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, D; MacDougall, R

    2016-06-15

    Purpose: Accurate values for Kerma-Area-Product (KAP) are needed for patient dosimetry and quality control for exams utilizing radiographic and/or fluoroscopic imaging. The KAP measured using a typical direct KAP meter built with parallel-plate transmission ionization chamber is not precise and depends on the energy spectrum of diagnostic x-rays. This study compared the accuracy and reproducibility of KAP derived from system parameters with values measured with a direct KAP meter. Methods: IEC tolerance for displayed KAP is specified up to ± 35% above 2.5 Gy-cm{sup 2} and manufacturer’s specifications are typically ± 25%. KAP values from the direct KAP meter driftsmore » with time leading to replacement or re-calibration. More precise and consistent KAP is achievable utilizing a database of known radiation output for various system parameters. The integrated KAP meter was removed from a radiography system. A total of 48 measurements of air kerma were acquired at x-ray tube potential from 40 to 150 kVp with 10 kVp increment using ion chamber type external dosimeter at free-in-air geometry for four different types of filter combinations following the manufacturer’s service procedure. These data were used to create updated correction factors that determine air kerma computationally for given system parameters. Results of calculated KAP were evaluated against results using a calibrated ion chamber based dosimeter and a computed radiography imaging plate to measure x-ray field size. Results: The accuracy of calculated KAP from the system parameters was better within 4% deviation in all diagnostic x-ray tube potentials tested from 50 to 140 kVp. In contrast, deviations of up to 25% were measured from KAP displayed from the direct KAP meter. Conclusion: The “calculated KAP” approach provides the nominal advantage of improved accuracy and precision of displayed KAP as well as reduced cost of calibrating or replacing integrated KAP meters.« less

  9. 77 FR 8722 - Airworthiness Directives; Eurocopter Deutschland Model EC135 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-15

    ... that in the past, the FADEC FAIL caution light illuminated on a few EC135 T1 helicopters. It states... metering unit and transmitted to the FADEC. This discrepancy led to the display of the FADEC FAIL caution... the FADEC to automatically meter fuel, indicated by a FADEC FAIL cockpit caution light, and subsequent...

  10. An Inexpensive, Very High Impedance Digital Voltmeter for Selective Electrodes.

    ERIC Educational Resources Information Center

    Caceci, Marco S.

    1984-01-01

    Describes a compact, digital voltmeter which exceeds, both in accuracy and input impedance, most commercial pH meters and potentiometers. The instrument consists of two parts: a very high impedance hybrid operational amplifier used as a voltage follower (ICH8500/A, Intersil) and a four and one-half digits LED display panel meter (RP-4500,…

  11. Airborne Laser Swath Mapping: Improved Penetration of Dense Vegetation Opens New Applications

    NASA Astrophysics Data System (ADS)

    Carter, W. E.; Shrestha, R. L.; Slatton, K. C.

    2009-12-01

    Historically, mapping structures and terrain obscured by dense forests has been problematical, because shadows limit or prevent the use of airborne photogrammetric techniques, and ground surveying techniques are slow, labor intensive, and too costly for many applications. Airborne laser swath mapping (ALSM) units with pulse rates of a few thousand to a few tens of thousands of pulses per second typically resulted in 1 or 2 points per square meter of terrain, which worked reasonably well in sparse to moderately forested areas. For example, data collected with a 30 kHz laser, provided sufficient returns from the ground in areas covered with redwood, mixed hardwoods, and conifer forests, to create 1 to 2 meter resolution bare earth digital elevation models (DEM). These DEMs were useful in studies of forest covered landslides, terraces, and fault lines. However, in dense semi-tropical areas of Florida, with primary and secondary canopies that include dense brush such as palmetto, the DEMs were significantly degraded, and in many areas it was not possible to derive bare earth DEMs that were reliable in height to better than 0.5 to 1.0 meter. In 2007 the UF purchased a second generation Optech ALSM unit that has decimeter accuracy ranging with pulse rates of 100 to 125 kHz. Flying at 600 meters AGL, 60 meters per second, and using a scan angle of ± 20 degrees and scan rate of 40 Hz, results in about 5 laser pulses per square meter within a single swath. In April 2009 a UF team collected ALSM observations covering approximately 2000 acres at Caracol, Belize, to support archaeological studies of the ancient (650 to 900AD) Mayan city, which is largely covered with dense jungle. By overlapping adjacent swaths by 50%, and flying the project area twice with orthogonal flight lines, an accumulated data set containing approximately 20 pulses per square meter, with a distribution of incident angles was realized. The Caracol area has been under study for 25 years and traditional mapping techniques involved cutting pathways through the jungle, typically at 50 meter intervals, and using transits, electronic distance measuring instruments and total stations to map visible features. Without completely clearing the vegetation, it was difficult for ground surveyors to identify and map all of the pertinent features, and preliminary analysis suggest that the ALSM data display areas of previously unmapped mounded settlement, as well as subtle features in the terrain, including shallow agricultural terraces. The ability to map structures and terrain in areas covered with semi-tropical and tropical forests and jungles opens new opportunities for archaeological studies, and promises to impact geological and geophysical studies in these difficult to map regions as well.

  12. Effect of image scaling on stereoscopic movie experience

    NASA Astrophysics Data System (ADS)

    Häkkinen, Jukka P.; Hakala, Jussi; Hannuksela, Miska; Oittinen, Pirkko

    2011-03-01

    Camera separation affects the perceived depth in stereoscopic movies. Through control of the separation and thereby the depth magnitudes, the movie can be kept comfortable but interesting. In addition, the viewing context has a significant effect on the perceived depth, as a larger display and longer viewing distances also contribute to an increase in depth. Thus, if the content is to be viewed in multiple viewing contexts, the depth magnitudes should be carefully planned so that the content always looks acceptable. Alternatively, the content can be modified for each viewing situation. To identify the significance of changes due to the viewing context, we studied the effect of stereoscopic camera base distance on the viewer experience in three different situations: 1) small sized video and a viewing distance of 38 cm, 2) television and a viewing distance of 158 cm, and 3) cinema and a viewing distance of 6-19 meters. We examined three different animations with positive parallax. The results showed that the camera distance had a significant effect on the viewing experience in small display/short viewing distance situations, in which the experience ratings increased until the maximum disparity in the scene was 0.34 - 0.45 degrees of visual angle. After 0.45 degrees, increasing the depth magnitude did not affect the experienced quality ratings. Interestingly, changes in the camera distance did not affect the experience ratings in the case of television or cinema if the depth magnitudes were below one degree of visual angle. When the depth was greater than one degree, the experience ratings began to drop significantly. These results indicate that depth magnitudes have a larger effect on the viewing experience with a small display. When a stereoscopic movie is viewed from a larger display, other experiences might override the effect of depth magnitudes.

  13. Grid-Connected Distributed Generation: Compensation Mechanism Basics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aznar, Alexandra Y; Zinaman, Owen R

    2017-10-02

    This short report defines compensation mechanisms for grid-connected, behind-the-meter distributed generation (DG) systems as instruments that comprise three core elements: (1) metering and billing arrangements, (2) sell rate design, and (3) retail rate design. This report describes metering and billing arrangements, with some limited discussion of sell rate design. We detail the three possible arrangements for metering and billing of DG: net energy metering (NEM); buy all, sell all; and net billing.

  14. Compensated count-rate circuit for radiation survey meter

    DOEpatents

    Todd, Richard A.

    1981-01-01

    A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

  15. Compensated count-rate circuit for radiation survey meter

    DOEpatents

    Todd, R.A.

    1980-05-12

    A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

  16. The Magic Ear: Another Approach to Automated Classroom Control.

    ERIC Educational Resources Information Center

    George, James R., III; And Others

    "Excessive" noise outburst behavior of 24 second graders was effectively controlled under automated stimulus conditions. A voice operated relay transmitted signals to an automated combination light display and outburst time/total running time meters; under 2 conditions, the light display functioned first as a primary, then as a secondary…

  17. Hey you! Shut the refrigerator door!

    NASA Astrophysics Data System (ADS)

    Fay, Sarah; Portenga, Angela

    1998-09-01

    The note discusses electrical power and energy and includes possible labs to be used in a physics classroom. It is based on our experimentation with a new device called the Watt-Watt/Hour Meter, which displays instantaneous power and cumulative energy readings of household electrical devices. Our experiments utilized this meter in conjunction with various appliances and focused primarily on its use with a refrigerator.

  18. Design and construction of portable survey meter

    NASA Astrophysics Data System (ADS)

    Singseeta, W.; Thong-aram, D.; Pencharee, S.

    2017-09-01

    This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.

  19. Relationship Between Metabolic Rate and Sea Depth in Bivalves and Gastropods

    NASA Astrophysics Data System (ADS)

    Ruiz, B. R.; Shih, B.; Heim, N.; Payne, J.

    2016-12-01

    The purpose of this study was to find and observe trends in the metabolic rate of bivalves and gastropod in regards to sea depth in order to see if all organisms follow a general trend for metabolism and to provide data to help future conservation efforts of these keystone organisms. Using geographic data produced by McClain et. al (2012) and body size data from Heim et. al (2015), the metabolic rate and sea depth data were plotted using the `R statistical software'. The Pearson correlation test was performed on each respective graph. Deep sea mollusks were considered those that resided at a water depth of 500 meters or deeper while shallow mollusks resided at a depth less than 500 meters. The gastropods showed positive correlations in the relationship between metabolic rate and ocean depth while bivalves showed a negative trend. When the metabolic rate versus minimum ocean depth was graphed, the graphs for deep bivalves and shallow gastropods returned bad p-values. From this data, it can be seen that water depth and metabolic rate have relationships, although different molluscan classes are adapted to their environments in different ways, as seen by the differences in the relationships between metabolic rates and ocean depth of the gastropods and bivalves. The results indicated that there is a general negative trend between metabolic rate and ocean depth of bivalves, and a positive relationship for gastropods. The difference in relationship in gastropods is thought to be attributed to the size trends of gastropods as they live in deeper waters, which is that gastropods increase in size across the bathyal region, and decrease as gastropods approach the extremely deep water. As displayed by the two different metabolic trends, this study shows the different ways molluscan classes have adapted to different evolutionary selection pressures.

  20. A Fixed-Base-Simulator Study of the Ability of a Pilot to Establish Close Orbits Around the Moon

    NASA Technical Reports Server (NTRS)

    Queijo, M. J.; Riley, Donald R.

    1961-01-01

    A study was made on a six-degree-of-freedom fixed-base simulator of the ability of human pilots to modify ballistic trajectories of a 5 space vehicle approaching the moon to establish a circular orbit about 50 miles above the lunar surface. The unmodified ballistic trajectories had miss distances from the lunar surface of from 40 to 80 miles, and a velocity range of from 8,200 to 8,700 feet per second at closest approach. The pilot was given control of the thrust (along the vehicle longitudinal axis) and torques about all three body axes. The information display given to the pilot was a hodograph of the vehicle rate of descent and circumferential velocity, an altimeter, and vehicle attitude and rate meters.

  1. Physical and physiological differences of backs and forwards from the Brazilian National rugby union team.

    PubMed

    Nakamura, Fábio Y; Pereira, Lucas A; Moraes, José E; Kobal, Ronaldo; Kitamura, Katia; Cal Abad, Cesar C; Teixeira Vaz, Luís M; Loturco, Irineu

    2017-12-01

    The aim of this study was to compare backs and forwards rugby union players recruited to a National team in the following physical and physiological indicators: anthropometrics, squat jump (SJ), countermovement jump (CMJ), 10- and 30-meter sprint, resting heart rate variability (HRV), Yo-Yo Test and heart rate (HR) at 2 minutes of test. The measurements were performed on the first day of a training camp planned to finely select the players who would participate in the 2016 America's Rugby Championship. The magnitude-based inference was used in the comparisons. Backs demonstrated almost certainly greater distance in the Yo-Yo Test (backs: 2305.9±231.3 meters; forwards: 1802.4±361.2 meters), higher vertical jump height in both SJ and CMJ (SJ: 44.0±5.3 cm vs. 37.6±5.4 cm; CMJ: 46.1±5.0 cm vs. 40.0±5.5 cm, for backs and forwards respectively), and superior sprint velocity in 10- and 30-m (10-m: 6.02±0.23 m.s-1 vs. 5.51±0.34 m.s-1; 30-m: 7.46±0.25 m.s-1 vs. 6.89±0.37 m.s-1, for backs and forwards respectively) than the forwards. In contrast, forwards were almost certainly taller and heavier than backs, and displayed higher sprint momentum in 10- and 30-meters (10 meters: 513.0±51.6 kg.m.s-1 vs. 598.4±53.1 kg.m.s-1; 30 meters: 635.3±56.1 kg.m.s-1 vs. 749.0±70.5 kg.m.s-1, for backs and forwards respectively). The submaximal HR in the first 2-minutes of the Yo-Yo test was likely lower in the backs than in the forwards (77.6±5.1% of the maximal HR vs. 81.3±5.4% of the maximal HR for backs and forwards respectively), while HRV indices were not different between backs and forwards. Playing position appears to be determined by the players' physical and physiological characteristics in top-level rugby union, and the submaximal HR measured during Yo-Yo test can be a simple alternative to discriminate backs and forwards.

  2. Geohydrology of the Englishtown Formation in the northern Coastal Plain of New Jersey

    USGS Publications Warehouse

    Nichols, W.D.

    1977-01-01

    The Englishtown Formation of the Matawan Group of Late Cretaceous age is exposed in the western part of the New Jeresy Coastal Plain along a northeast-southwest trending zone extending from Raritan Bay to Delaware Bay. In outcrop, in the northern part of the Coastal Plain, the Englishtown typically consists of a series of thin, cross-stratified, fine- to medium-grained lignitic quartz sand beds intercalated with thin beds of sandy silty clay and clayey silt, ranging in total thickness from about 140 feet (43 meters) near Raritan Bay to about 50 feet (15 meters) near Trenton. In the subsurface of the northern part of the Coastal Plain, the formation retains most of the lithologic characteristics displayed in outcrop. In northern and eastern Ocean County the Englishtown can be subdivided into three distinct lithologic units; upper and lower units of quartz sand with thin interbeds of dark sandy silt, separated by a thick sequence of sandy and clayey lignitic silt. The confined part of the aquifer in the Englishtown Formation is utilized as a source of water over an area of about 1,100 square miles (2,849 square kilometers) of the New Jersey Coastal Plain and is an important source of supply in Monmouth and northern Ocean Counties. The annual average rate of withdrawal from the aquifer in the two-county area increased from 5.5 million gallons per day (0.24 cubic meters per second) in 1959 to 9.5 million gallons per day (0.4 cubic meters per second) in 1970. Water levels in parts of this area were declining 8 to 12 feet (2.4 to 3.6 meters) per year as of 1970 and they declined as much as 140 feet (43 meters) between 1959 and 1970 near pumping centers. The aquifer transmissivity ranges from 2,400 square feet per day to 650 square feet per day (223 square meters per day to 60 square meters per day); the estimated hydraulic conductivity ranges from about 11 feet per day to 20 feet per day (3.3 meters per day to 6.1 meters per day); and the storage coefficient ranges from 8 x 10-5 to 3 x 10-4. The underlying and overlying confining beds, which have an average thickness of 200 feet (61 meters) and 40 feet (12 meters), respectively, have vertical hydraulic conductivities on the order of 1 x 10-5 feet per day (3 x 10-6 meters per day) and specific storage on the order of 8 x 10-5 ft-1 (2.4 x 10-5 m-1). The Englishtown aquifer is an integral part of the complex multi- aquifer system of the New Jersey Coastal Plain. The withdrawal of water from the Englishtown aquifer has had a marked effect on the water level in the overlying Moutn Laurel aquifer, and these effects will continue so long as the water level in the Englishtown continues to decline. Any increase in the development of the Mount Laurel aquifer that reduces the volume of leakage to the Englishtown will cause an increase in the rate of water-level decline in the Englishtown even with no increase in direct withdrawals. The interrelationship and interdependency between pumping stresses in individual aquifers within the complex Coastal Plain aquifer sytem must be recognized and appreciated, and the hydrodynamics of all parts of the system must be considered if reliable predictions of aquifer response to these stresses are to be made. Such predictions generally require a simulation model analysis of the system.

  3. Artillery Engagement Simulation

    DTIC Science & Technology

    1980-05-01

    coordinate* of the burst point to 10 meter accuracy (4 digit number). 7. Press R/S. Calculator will run for approximately one second and display the...northing coordinate* of the burst point to 10 meter accuracy (4 digit number). 8. If it is not desired to send azimuth and distance instructions to the...Now Delhi 1 USA Agey for Aviation Safety, Ft Rucker. ATTN: Educ Advisor I Pars Rsch Ofc, Libary , AKA. Israel Defense Forces I USA Aviation Sch. Ft

  4. Advanced optical network architecture for integrated digital avionics

    NASA Astrophysics Data System (ADS)

    Morgan, D. Reed

    1996-12-01

    For the first time in the history of avionics, the network designer now has a choice in selecting the media that interconnects the sources and sinks of digital data on aircraft. Electrical designs are already giving way to photonics in application areas where the data rate times distance product is large or where special design requirements such as low weight or EMI considerations are critical. Future digital avionic architectures will increasingly favor the use of photonic interconnects as network data rates of one gigabit/second and higher are needed to support real-time operation of high-speed integrated digital processing. As the cost of optical network building blocks is reduced and as temperature-rugged laser sources are matured, metal interconnects will be forced to retreat to applications spanning shorter and shorter distances. Although the trend is already underway, the widespread use of digital optics will first occur at the system level, where gigabit/second, real-time interconnects between sensors, processors, mass memories and displays separated by a least of few meters will be required. The application of photonic interconnects for inter-printed wiring board signalling across the backplane will eventually find application for gigabit/second applications since signal degradation over copper traces occurs before one gigabit/second and 0.5 meters are reached. For the foreseeable future however, metal interconnects will continue to be used to interconnect devices on printed wiring boards since 5 gigabit/second signals can be sent over metal up to around 15 centimeters. Current-day applications of optical interconnects at the system level are described and a projection of how advanced optical interconnect technology will be driven by the use of high speed integrated digital processing on future aircraft is presented. The recommended advanced network for application in the 2010 time frame is a fiber-based system with a signalling speed of around 2-3 gigabits per second. This switch-based unified network will interconnect sensors, displays, mass memory and controls and displays to computer modules within the processing complex. The characteristics of required building blocks needed for the future are described. These building blocks include the fiber, an optical switch, a laser-based transceiver, blind-mate connectors and an optical backplane.

  5. The effects of vertical motion on the performance of current meters

    USGS Publications Warehouse

    Thibodeaux, K.G.; Futrell, J. C.

    1987-01-01

    A series of tests to determine the correction coefficients for Price type AA and Price type OAA current meters, when subjected to vertical motion in a towing tank, have been conducted. During these tests, the meters were subjected to vertical travel that ranged from 1.0 to 4.0 ft and vertical rates of travel that ranged from 0.33 to 1.20 ft/sec while being towed through the water at speeds ranging from 0 to 8 ft/sec. The tests show that type AA and type OAA current meters are affected adversely by the rate of vertical motion and the distance of vertical travel. In addition, the tests indicate that when current meters are moved vertically, correction coefficients must be applied to the observed meter velocities to correct for the registration errors that are induced by the vertical motion. The type OAA current meter under-registers and the type AA current meter over-registers in observed meter velocity. These coefficients for the type OAA current meter range from 0.99 to 1.49 and for the type AA current meter range from 0.33 to 1.07. When making current meter measurements from a boat or a cableway, errors in observed current meter velocity will occur when the bobbing of a boat or cableway places the current meter into vertical motion. These errors will be significant when flowing water is < 2 ft/sec and the rate of vertical motion is > 0.3 ft/sec. (Author 's abstract)

  6. Relations between Municipal Water Use and Selected Meteorological Parameters and Drought Indices, East-Central and Northeast Florida

    USGS Publications Warehouse

    Murray, Louis C.

    2009-01-01

    Water-use data collected between 1992 and 2006 at eight municipal water-supply utilities in east-central and northeast Florida were analyzed to identify seasonal trends in use and to quantify monthly variations. Regression analyses were applied to identify significant correlations between water use and selected meteorological parameters and drought indices. Selected parameters and indices include precipitation (P), air temperature (T), potential evapotranspiration (PET), available water (P-PET), monthly changes in these parameters (Delta P, Delta T, Delta PET, Delta(P-PET), the Palmer Drought Severity Index (PDSI), and the Standardized Precipitation Index (SPI). Selected utilities include the City of Daytona Beach (Daytona), the City of Eustis (Eustis), Gainesville Regional Utilities (GRU), Jacksonville Electric Authority (JEA), Orange County Utilities (OCU), Orlando Utilities Commission (OUC), Seminole County Utilities (SCU), and the City of St. Augustine (St. Augustine). Water-use rates at these utilities in 2006 ranged from about 3.2 million gallons per day at Eustis to about 131 million gallons per day at JEA. Total water-use rates increased at all utilities throughout the 15-year period of record, ranging from about 4 percent at Daytona to greater than 200 percent at OCU and SCU. Metered rates, however, decreased at six of the eight utilities, ranging from about 2 percent at OCU and OUC to about 17 percent at Eustis. Decreases in metered rates occurred because the number of metered connections increased at a greater rate than did total water use, suggesting that factors other than just population growth may play important roles in water-use dynamics. Given the absence of a concurrent trend in precipitation, these decreases can likely be attributed to changes in non-climatic factors such as water-use type, usage of reclaimed water, water-use restrictions, demographics, and so forth. When averaged for the eight utilities, metered water-use rates depict a clear seasonal pattern in which rates were lowest in the winter and greatest in the late spring. Averaged water-use rates ranged from about 9 percent below the 15-year daily mean in January to about 11 percent above the daily mean in May. Water-use rates were found to be statistically correlated to meteorological parameters and drought indices, and to be influenced by system memory. Metered rates (in gallons per day per active metered connection) were consistently found to be influenced by P, T, PET, and P-PET and changes in these parameters that occurred in prior months. In the single-variant analyses, best correlations were obtained by fitting polynomial functions to plots of metered rates versus moving-averaged values of selected parameters (R2 values greater than 0.50 at three of eight sites). Overall, metered water-use rates were best correlated with the 3- to 4-month moving average of Delta T or Delta PET (R2 values up to 0.66), whereas the full suite of meteorological parameters was best correlated with metered rates at Daytona and least correlated with rates at St. Augustine. Similarly, metered rates were substantially better correlated with moving-averaged values of precipitation (significant at all eight sites) than with single (current) monthly values (significant at only three sites). Total and metered water-use rates were positively correlated with T, PET, Delta P, Delta T, and Delta PET, and negatively correlated with P, P-PET, Delta (P-PET), PDSI, and SPI. The drought indices were better correlated with total water-use rates than with metered rates, whereas metered rates were better correlated with meteorological parameters. Multivariant analyses produced fits of the data that explained a greater degree of the variance in metered rates than did the single-variant analyses. Adjusted R2 values for the 'best' models ranged from 0.79 at JEA to 0.29 at St. Augustine and exceeded 0.60 at five of eight sites. The amount of available water (P-PET) was the si

  7. Mount Everest region as seen from the STS-66 orbiter Atlantis

    NASA Image and Video Library

    1994-11-14

    STS066-124-059 (3-14 Nov. 1994) --- Mount Everest region, Nepal and China. Low morning Sun highlights Mount Everest (the highest mountain in the world at 8,848 meters), Cho Oyu (8,153 meters) to the northwest, and other peaks of "The Roof of the World". New snow seems to be confined to the highest peaks. Abundant details of glacier surfaces, including moraines, crevasse fields, and ice falls are displayed for study.

  8. Analog/digital pH meter system I.C.

    NASA Technical Reports Server (NTRS)

    Vincent, Paul; Park, Jea

    1992-01-01

    The project utilizes design automation software tools to design, simulate, and fabricate a pH meter integrated circuit (IC) system including a successive approximation type seven-bit analog to digital converter circuits using a 1.25 micron N-Well CMOS MOSIS process. The input voltage ranges from 0.5 to 1.0 V derived from a special type pH sensor, and the output is a three-digit decimal number display of pH with one decimal point.

  9. Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Pei-Jan P., E-mail: Pei-Jan.Lin@vcuhealth.org; Schueler, Beth A.; Balter, Stephen

    2015-12-15

    Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TGmore » 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.« less

  10. Accessibility Attributes of Blood Glucose Meter and Home Blood Pressure Monitor Displays for Visually Impaired Persons

    PubMed Central

    Blubaugh, Morgan V.; Uslan, Mark M.

    2012-01-01

    The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, full-functionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39–1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55–96% and font height ranging 0.28–0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. PMID:22538132

  11. Accessibility attributes of blood glucose meter and home blood pressure monitor displays for visually impaired persons.

    PubMed

    Blubaugh, Morgan V; Uslan, Mark M

    2012-03-01

    The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, fullfunctionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39-1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55-96% and font height ranging 0.28-0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection. © 2012 Diabetes Technology Society.

  12. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    NASA Astrophysics Data System (ADS)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing three types of retail rates (a flat rate, a time-of-use rate, and real-time pricing) from these wholesale price profiles, I examine bill savings from PV generation for the ten wholesale market scenarios under net metering and an alternative to net metering where hourly excess PV generation is compensated at the wholesale price. Most generally, I challenge the common assertion that PV compensation is likely to stay constant (or rise) due to constant (or rising) retail rates, and find that future electricity market scenarios can drive substantial changes in residential retail rates and that these changes, in concert with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV.

  13. Integrating seepage heterogeneity with the use of ganged seepage meters

    USGS Publications Warehouse

    Rosenberry, D.O.

    2005-01-01

    The usefulness of standard half-barrel seepage meters for measurement of fluxes between groundwater, and surface water is limited by the small bed area that each measurement represents and the relatively large associated labor costs. Standard half-barrel cylinders were ganged together to allow one measurement of the summed seepage through all of the meters, reducing labor cost and increasing the representative area of measurement. Comparisons of ganged versus individual-meter measurements at two lakes, under both inseepage and outseepage conditions, indicate little loss of efficiency resulting from routing seepage water through the ganging system. Differences between summed and ganged seepage rates were not significant for all but the fastest rates of seepage. At flow rates greater than about 250 mL min-1, ganged values were as low as 80% of summed values. Ganged-meter head losses also were calculated to determine their significance relative to hydraulic-head gradients measured at the field sites. The calculated reduction in hydraulic gradient beneath the seepage meters was significant only for the largest measured seepage rates. A calibration tank was used to determine single-meter and ganged-meter efficiencies compared to known seepage rates. Single-cylinder seepage meters required an average correction factor of 1.05 to convert measured to actual values, whereas the ganged measurements made in the tank required a larger correction factor of 1.14. Although manual measurements were used in these tests, the concept of ganging seepage cylinders also would be useful when used in conjunction with automated flowmeters. ?? 2005, by the American Society of Limnology and Oceanography, Inc.

  14. Dynamics of Unusual Debris Flows on Martian Sand Dunes

    NASA Technical Reports Server (NTRS)

    Miyamoto, Hideaki; Dohm, James M.; Baker, Victor R.; Beyer, Ross A.; Bourke, Mary

    2004-01-01

    Gullies that dissect sand dunes in Russell impact crater often display debris flow-like deposits in their distal reaches. The possible range of both the rheological properties and the flow rates are estimated using a numerical simulation code of a Bingham plastic flow to help explain the formation of these features. Our simulated results are best explained by a rapid debris flow. For example, a debris flow with the viscosity of 10(exp 2) Pa s and the yield strength of 10(exp 2) Pa can form the observed deposits with a flow rate of 0.5 cu m/s sustained over several minutes and total discharged water volume on the order of hundreds of cubic meters, which may be produced by melting a surface layer of interstitial ice within the dune deposits to several centimeters depth.

  15. Sedimentation History of Lago Dos Bocas, Puerto Rico, 1942-2005

    USGS Publications Warehouse

    Soler-López, Luis R.

    2007-01-01

    The Lago Dos Bocas Dam, located in the municipality of Utuado in north central Puerto Rico, was constructed in 1942 for hydroelectric power generation. The reservoir had an original storage capacity of 37.50 million cubic meters and a drainage area of 440 square kilometers. In 1948, the construction of the Lago Caonillas Dam on the Rio Caonillas branch of Lago Dos Bocas reduced the natural sediment-contributing drainage area to 310 square kilometers; therefore, the Lago Caonillas Dam is considered an effective sediment trap. Sedimentation in Lago Dos Bocas reservoir has reduced the storage capacity from 37.50 million cubic meters in 1942 to 17.26 million cubic meters in 2005, which represents a storage loss of about 54 percent. The long-term annual water-storage capacity loss rate remained nearly constant at about 320,000 cubic meters per year to about 1997. The inter-survey sedimentation rate between 1997 and 1999, however, is higher than the long-term rate at about 1.09 million cubic meters per year. Between 1999 and 2005 the rate is lower than the long-term rate at about 0.13 million cubic meters per year. The Lago Dos Bocas effective sediment-contributing drainage area had an average sediment yield of about 1,400 cubic meters per square kilometer per year between 1942 and 1997. This rate increased substantially by 1999 to about 4,600 cubic meters per square kilometer per year, probably resulting from the historical magnitude floods caused by Hurricane Georges in 1998. Recent data indicate that the Lago Dos Bocas drainage area sediment yield decreased substantially to about 570 cubic meters per square kilometer per year, which is much lower than the 1942-1997 area normalized sedimentation rate of 1,235 cubic meters per square kilometer per year. The impact of Hurricane Georges on the basin sediment yield could have been the cause of this change, since the magnitude of the floods could have nearly depleted the Lago Dos Bocas drainage area of easily erodible and transportable bed sediment. This report summarizes the historical change in water-storage capacity of Lago Dos Bocas between 1942 and 2005.

  16. Super long viewing distance light homogeneous emitting three-dimensional display

    NASA Astrophysics Data System (ADS)

    Liao, Hongen

    2015-04-01

    Three-dimensional (3D) display technology has continuously been attracting public attention with the progress in today's 3D television and mature display technologies. The primary characteristics of conventional glasses-free autostereoscopic displays, such as spatial resolution, image depths, and viewing angle, are often limited due to the use of optical lenses or optical gratings. We present a 3D display using MEMS-scanning-mechanism-based light homogeneous emitting (LHE) approach and demonstrate that the display can directly generate an autostereoscopic 3D image without the need for optical lenses or gratings. The generated 3D image has the advantages of non-aberration and a high-definition spatial resolution, making it the first to exhibit animated 3D images with image depth of six meters. Our LHE 3D display approach can be used to generate a natural flat-panel 3D display with super long viewing distance and alternative real-time image update.

  17. SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, C; Thai, L; Wagner, L

    Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the imagemore » receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.« less

  18. Radiation dose-rate meter using an energy-sensitive counter

    DOEpatents

    Kopp, Manfred K.

    1988-01-01

    A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

  19. Offshore multiphase meter nears acceptable accuracy level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaisford, S.; Amdal, J.; Berentsen, H.

    1993-05-17

    Companies worldwide are looking for new production methods for offshore oil fields. In many areas, undeveloped smaller fields cannot bear the cost of dedicated production facilities. Multiphase transportation to existing production facilities can extend the distance over which unseparated oil, water, and gas streams can be transported, from a limit of several kilometers today to perhaps 200 km in the future. An encouraging multiphase meter test was sponsored by Saga Petroleum AS and carried out by Den norske stats oljeselskap AS (Statoil) on the Gullfaks B platform, Norwegian sector of the North Sea. The complete multiphase meter has two separatemore » meters. One is the composition meter for measuring the instantaneous volume or mass fractions of oil, water, and gas in the sensor. The other is a velocity meter for determining the speed of the mixture through the sensor. An instantaneous volume or mass production rate for each component is calculated by combining the outputs from the two meters. The paper describes the multiphase meter; measurements; limitations; the test setup; calibration; test results for the composition meter, velocity meter, and production rates; and future plans.« less

  20. Groundwater-Seepage Meter

    NASA Technical Reports Server (NTRS)

    Walthall, Harry G.; Reay, William G.

    1993-01-01

    Instrument measures seepage of groundwater into inland or coastal body of water. Positioned at depth as great as 40 meters, and measures flow at low rate and low pressure differential. Auxiliary pressure meter provides data for correlation of flow of groundwater with tides and sea states. Seepage meter operates independently for several weeks. Its sampling rate adjusted to suit hydrologic conditions; to measure more frequently when conditions changing rapidly. Used in water-quality management and for biological and geological research. Potential industrial uses include measurement of seepage of caustic and corrosive liquids.

  1. Speedy Alchemy.

    ERIC Educational Resources Information Center

    Deininger, Rolf A.; Berger, Carl F., Jr.

    1983-01-01

    Provides instructions for interfacing a pH meter directly to an Apple II microcomputer without an analog-to-digital converter. Includes program listing (with enough remark statements to make it self-documenting) in Integer Basic to display the pH readings. (Author/JN)

  2. Big Data on the Big Screen

    NASA Image and Video Library

    2013-10-17

    The center of the Milky Way galaxy imaged by NASA Spitzer Space Telescope is displayed on a quarter-of-a-billion-pixel, high-definition 23-foot-wide 7-meter LCD science visualization screen at NASA Ames Research Center.

  3. A volumetric meter chip for point-of-care quantitative detection of bovine catalase for food safety control.

    PubMed

    Cui, Xingye; Hu, Jie; Choi, Jane Ru; Huang, Yalin; Wang, Xuemin; Lu, Tian Jian; Xu, Feng

    2016-09-07

    A volumetric meter chip was developed for quantitative point-of-care (POC) analysis of bovine catalase, a bioindicator of bovine mastitis, in milk samples. The meter chip displays multiplexed quantitative results by presenting the distance of ink bar advancement that is detectable by the naked eye. The meter chip comprises a poly(methyl methacrylate) (PMMA) layer, a double-sided adhesive (DSA) layer and a glass slide layer fabricated by the laser-etching method, which is typically simple, rapid (∼3 min per chip), and cost effective (∼$0.2 per chip). Specially designed "U shape" reaction cells are covered by an adhesive tape that serves as an on-off switch, enabling the simple operation of the assay. As a proof of concept, we employed the developed meter chip for the quantification of bovine catalase in raw milk samples to detect catalase concentrations as low as 20 μg/mL. The meter chip has great potential to detect various target analytes for a wide range of POC applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Design of PH sensor signal acquisition and display system

    NASA Astrophysics Data System (ADS)

    Qian, Huifa; Zhang, Quanzhu; Deng, Yonghong

    2017-06-01

    With the continuous development of sensor manufacturing technology, how to better deal with the signal is particularly important. PH value of the sensor voltage generated by the signal as a signal, through the MCU acquisition A / D conversion, and ultimately through the digital display of its PH value. The system uses hardware and software to achieve the results obtained with the high-precision PH meter to strive to improve the accuracy and reduce error.

  5. Noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump.

    PubMed

    Kosaka, Ryo; Fukuda, Kyohei; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2013-01-01

    In order to monitor the condition of a patient using a left ventricular assist system (LVAS), blood flow should be measured. However, the reliable determination of blood-flow rate has not been established. The purpose of the present study is to develop a noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump. The flow meter uses the centrifugal force generated by the flow rate in the curved cannula. Two strain gauges served as sensors. The first gauges were attached to the curved area to measure static pressure and centrifugal force, and the second gauges were attached to straight area to measure static pressure. The flow rate was determined by the differences in output from the two gauges. The zero compensation was constructed based on the consideration that the flow rate could be estimated during the initial driving condition and the ventricular suction condition without using the flow meter. A mock circulation loop was constructed in order to evaluate the measurement performance of the developed flow meter with zero compensation. As a result, the zero compensation worked effectively for the initial calibration and the zero-drift of the measured flow rate. We confirmed that the developed flow meter using a curved cannula with zero compensation was able to accurately measure the flow rate continuously and noninvasively.

  6. A Tube Seepage Meter for In Situ Measurement of Seepage Rate and Groundwater Sampling.

    PubMed

    Solder, John E; Gilmore, Troy E; Genereux, David P; Solomon, D Kip

    2016-07-01

    We designed and evaluated a "tube seepage meter" for point measurements of vertical seepage rates (q), collecting groundwater samples, and estimating vertical hydraulic conductivity (K) in streambeds. Laboratory testing in artificial streambeds show that seepage rates from the tube seepage meter agreed well with expected values. Results of field testing of the tube seepage meter in a sandy-bottom stream with a mean seepage rate of about 0.5 m/day agreed well with Darcian estimates (vertical hydraulic conductivity times head gradient) when averaged over multiple measurements. The uncertainties in q and K were evaluated with a Monte Carlo method and are typically 20% and 60%, respectively, for field data, and depend on the magnitude of the hydraulic gradient and the uncertainty in head measurements. The primary advantages of the tube seepage meter are its small footprint, concurrent and colocated assessments of q and K, and that it can also be configured as a self-purging groundwater-sampling device. © 2015, National Ground Water Association.

  7. The smart meter and a smarter consumer: quantifying the benefits of smart meter implementation in the United States.

    PubMed

    Cook, Brendan; Gazzano, Jerrome; Gunay, Zeynep; Hiller, Lucas; Mahajan, Sakshi; Taskan, Aynur; Vilogorac, Samra

    2012-04-23

    The electric grid in the United States has been suffering from underinvestment for years, and now faces pressing challenges from rising demand and deteriorating infrastructure. High congestion levels in transmission lines are greatly reducing the efficiency of electricity generation and distribution. In this paper, we assess the faults of the current electric grid and quantify the costs of maintaining the current system into the future. While the proposed "smart grid" contains many proposals to upgrade the ailing infrastructure of the electric grid, we argue that smart meter installation in each U.S. household will offer a significant reduction in peak demand on the current system. A smart meter is a device which monitors a household's electricity consumption in real-time, and has the ability to display real-time pricing in each household. We conclude that these devices will provide short-term and long-term benefits to utilities and consumers. The smart meter will enable utilities to closely monitor electricity consumption in real-time, while also allowing households to adjust electricity consumption in response to real-time price adjustments.

  8. Flowmeter for Clear and Translucent Fluids

    NASA Technical Reports Server (NTRS)

    White, P. R.

    1985-01-01

    Transducer with only three moving parts senses flow of clear or translucent fluid. Displacement of diaphragm by force of flow detected electrooptically and displayed by panel meter or other device. Transducer used to measure flow of gasoline to automobile engine.

  9. [Adhesion loss of syrups in a metering glass which consists of a low surface free energy material].

    PubMed

    Yamamoto, Yoshihisa; Suzuki, Toyofumi; Hashizaki, Kaname; Ogura, Masao; Umeda, Yukiko; Hidaka, Shinji; Fukami, Toshiro; Tomono, Kazuo

    2010-08-01

    We previously reported a strong positive correlation between syrup viscosity and the rate of syrup loss due to adhesion to a glass metering device. In this study, we examined differences in the surface free energies of metering devices made of different polymeric materials, since reducing adhesion loss to metering devices could improve the efficiency of drug preparation involving highly viscous syrups. Among metering devices made of glass only, glass with a silicone coating (SLC), polypropylene (PP), and polymethylpentene (PMP) the surface free energy of the glass-only metering device was the highest (49.2 mN/m). The adhesion loss obtained for highly viscous syrups in the PP and PMP metering devices was significantly lower than that of the glass metering device. Measurements of syrup contact angles suggested that in metering devices made of PP and PMP, which have low surface free energies, a decrease in the spreading wetting of syrups was a factor in reducing the rate of adhesion loss. Thus irrespective of the syrup viscosity being measured, metering devices produced from materials with low surface free energies can reduce the time required to prepare prescriptions without compromising the accuracy of drug preparation.

  10. Measuring Your Peak Flow Rate

    MedlinePlus

    ... Living with Asthma > Managing Asthma Measuring Your Peak Flow Rate Download Instructions A peak flow meter is ... to use. Who Benefits from Using a Peak Flow Meter? Many healthcare providers believe that people who ...

  11. The Sharjah Center for Astronomy and Space Sciences (SCASS 2015): Concept and Resources

    NASA Astrophysics Data System (ADS)

    Naimiy, Hamid M. K. Al

    2015-08-01

    The Sharjah Center for Astronomy and Space Sciences (SCASS) was launched this year 2015 at the University of Sharjah in the UAE. The center will serve to enrich research in the fields of astronomy and space sciences, promote these fields at all educational levels, and encourage community involvement in these sciences. SCASS consists of:The Planetarium: Contains a semi-circle display screen (18 meters in diameter) installed at an angle of 10° which displays high-definition images using an advanced digital display system consisting of seven (7) high-performance light-display channels. The Planetarium Theatre offers a 200-seat capacity with seats placed at highly calculated angles. The Planetarium also contains an enormous star display (Star Ball - 10 million stars) located in the heart of the celestial dome theatre.The Sharjah Astronomy Observatory: A small optical observatory consisting of a reflector telescope 45 centimeters in diameter to observe the galaxies, stars and planets. Connected to it is a refractor telescope of 20 centimeters in diameter to observe the sun and moon with highly developed astronomical devices, including a digital camera (CCD) and a high-resolution Echelle Spectrograph with auto-giving and remote calibration ports.Astronomy, space and physics educational displays for various age groups include:An advanced space display that allows for viewing the universe during four (4) different time periods as seen by:1) The naked eye; 2) Galileo; 3) Spectrographic technology; and 4) The space technology of today.A space technology display that includes space discoveries since the launching of the first satellite in 1940s until now.The Design Concept for the Center (450,000 sq. meters) was originated by HH Sheikh Sultan bin Mohammed Al Qasimi, Ruler of Sharjah, and depicts the dome as representing the sun in the middle of the center surrounded by planetary bodies in orbit to form the solar system as seen in the sky.

  12. AIS-2 automated meter for spectra recorded on photographic plates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramendik, G.I.; Khromov, A.Yu.; Volkov, V.L.

    1986-10-01

    The AIS-2 system contains a G-2 microdensitometer, an Elektronika D3-28 microcomputer, an Shch1312 digital voltmeter, and an S1-72 oscilloscope, which serves as a graphics display. The system operates in the interactive mode.

  13. 77 FR 65408 - Outer Continental Shelf (OCS) Western Planning Area (WPA) Gulf of Mexico (GOM) Oil and Gas Lease...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... leases in depths less than 400 meters with an initial period longer than 5 years, royalty rates, minimum... $25.00 per acre or fraction thereof for blocks in water depths of less than 400 meters. $100.00 per acre or fraction thereof for blocks in water depths of 400 meters or deeper. Rental Rates Annual rental...

  14. Sedimentation survey of Lago Cerrillos, Ponce, Puerto Rico, April-May 2008

    USGS Publications Warehouse

    Soler-López, Luis R.

    2011-01-01

    Lago Cerrillos dam, located in the municipality of Ponce in southern Puerto Rico, was constructed in 1991 as part of the multipurpose Rio Portugues and Bucana Project. This project provides flood protection, water supply, and recreation facilities for the municipio of Ponce. The reservoir had an original storage capacity of 38.03 million cubic meters at maximum conservation pool elevation of 174.65 meters above mean sea level and a drainage area of 45.32 square kilometers. Sedimentation in Lago Cerrillos reservoir has reduced the storage capacity from 38.03 million cubic meters in 1991 to 37.26 million cubic meters in 2008, which represents a total storage loss of about 2 percent. During July 29 to August 23, 2002, 8,492 cubic meters of sediment were removed from the Rio Cerrillos mouth of the reservoir. Taking into account this removed material, the total water-storage loss as of 2008 is 778,492 cubic meters, and the long-term annual water-storage capacity loss rate is about 45,794 cubic meters per year or about 0.12 percent per year. The Lago Cerrillos net sediment-contributing drainage area has an average sediment yield of about 1,069 cubic meters per square kilometer per year. Sediment accumulation in Lago Cerrillos is not uniformly distributed and averages about 3 meters in thickness. This represents a sediment deposition rate of about 18 centimeters per year. On the basis of the 2008 reservoir storage capacity of 37.26 million cubic meters per year and a long-term sedimentation rate of 45,794 cubic meters per year, Lago Cerrillos is estimated to have a useful life of about 814 years or until the year 2822.

  15. Discuss the testing problems of ultraviolet irradiance meters

    NASA Astrophysics Data System (ADS)

    Ye, Jun'an; Lin, Fangsheng

    2014-09-01

    Ultraviolet irradiance meters are widely used in many areas such as medical treatment, epidemic prevention, energy conservation and environment protection, computers, manufacture, electronics, ageing of material and photo-electric effect, for testing ultraviolet irradiance intensity. So the accuracy of value directly affects the sterile control in hospital, treatment, the prevention level of CDC and the control accuracy of curing and aging in manufacturing industry etc. Because the display of ultraviolet irradiance meters is easy to change, in order to ensure the accuracy, it needs to be recalibrated after being used period of time. By the comparison with the standard ultraviolet irradiance meters, which are traceable to national benchmarks, we can acquire the correction factor to ensure that the instruments working under accurate status and giving the accurate measured data. This leads to an important question: what kind of testing device is more accurate and reliable? This article introduces the testing method and problems of the current testing device for ultraviolet irradiance meters. In order to solve these problems, we have developed a new three-dimensional automatic testing device. We introduce structure and working principle of this system and compare the advantages and disadvantages of two devices. In addition, we analyses the errors in the testing of ultraviolet irradiance meters.

  16. Bio-recognition and detection using liquid crystals.

    PubMed

    Hussain, A; Pina, A S; Roque, A C A

    2009-09-15

    Liquid crystals (LCs) are used extensively by the electronics industry as display devices. Advances in the understanding of the liquid crystalline phase and the chemistry therein lead to the development of LC exhibiting faster switching speed with greater twist angle. This in turn lead to the emergence of liquid crystal displays, rendering dial-and-needle based displays (such as those used in various meters) and cathode ray tubes obsolete. In this article, we review the history of LC and their emergence as an invaluable material for display devices and the more recent discovery of their use as sensing elements in biosensors. This new application of LC as tools in the development of fast and simple biosensors is envisaged to gain more importance in the foreseeable future.

  17. Temporal variability of submarine groundwater discharge: Assessments via radon and seep meters, the southern carmel coast, Israel

    USGS Publications Warehouse

    Weinstein, Y.; Shalem, Y.; Burnett, W.C.; Swarzenski, P.W.; Herut, B.

    2007-01-01

    Seep meter data from Dor Bay, Israel, showed a steady decrease in submarine groundwater discharge (SGD) rates between March and July 2006 (averages of 34, 10.4 and 1.5 cm d-1 in March, May and July, respectively), while estimates based on radon time series showed remarkably uniform averages (8 cm d-1). The May seep meter data show a rough positive correlation with sea level, unlike the negative correlation shown by the Rn-calculated rates. Smaller-size meters, deployed in July adjacent to the regular-size ones, showed significantly higher rates (10 cm d-1), which negatively correlated with salinity. It is suggested that the decreased rates documented by the seep meters are the result of an increased shallow seawater recharge in the bay (due to decreasing hydraulic gradients). This is not captured by the radon, since recharging water is radon-poor. The positive correlation of discharge with sea level is due to increased seawater recycling in times of high sea stand. Copyright ?? 2007 IAHS Press.

  18. Fission Meter Information Barrier Attribute Measurement System - NA-243 FNI/UKC FY2017 Task 1-2 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerr, P. L.; Decman, D.; Prasad, M.

    An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements inmore » a way the does not reveal sensitive information. In full IB mode, only the pass/fail result is displayed as a “Mass <= Threshold Amount” or “Mass >= Threshold Amount” as shown in Figure 4. This can easily be adapted to a red/green “lights” display similar to the Detective IB system for Pu isotopics as shown in Figure 6. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.« less

  19. NASA Earth Observing-1 Keeps Watchful Eye on South American Volcano Copahue

    NASA Image and Video Library

    2013-06-07

    NASA Earth Observing-1 EO-1 spacecraft observed Copahue volcano, a 2965 meter high volcano on the Chile-Argentina border, on Jun. 4, 2013. Having recently displayed signs of unrest, the volcano is under close scrutiny by local volcanologists.

  20. LINEAR COUNT-RATE METER

    DOEpatents

    Henry, J.J.

    1961-09-01

    A linear count-rate meter is designed to provide a highly linear output while receiving counting rates from one cycle per second to 100,000 cycles per second. Input pulses enter a linear discriminator and then are fed to a trigger circuit which produces positive pulses of uniform width and amplitude. The trigger circuit is connected to a one-shot multivibrator. The multivibrator output pulses have a selected width. Feedback means are provided for preventing transistor saturation in the multivibrator which improves the rise and decay times of the output pulses. The multivibrator is connected to a diode-switched, constant current metering circuit. A selected constant current is switched to an averaging circuit for each pulse received, and for a time determined by the received pulse width. The average output meter current is proportional to the product of the counting rate, the constant current, and the multivibrator output pulse width.

  1. Advanced Metering Infrastructure based on Smart Meters

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  2. Hydrologic Interpretations of Long-Term Gravity Records at Tucson, Arizona

    NASA Astrophysics Data System (ADS)

    Pool, D. R.; Kennedy, J.; MacQueen, P.; Niebauer, T. M.

    2016-12-01

    The USGS Arizona Water Science Center monitors groundwater storage using gravity methods at sites across the western United States. A site at the USGS office in Tucson serves as a test station that has been monitored since 1997 using several types of gravity meters. Prior to 2007, the site was observed twice each year by the National Geodetic Survey using an FG5 absolute gravity meter for the purpose of establishing control for local relative gravity surveys of aquifer storage change. Beginning in 2003 the site has also served as a reference to verify the accuracy of an A10 absolute gravity meter that is used for field surveys. The site is in an alluvial basin where gravity can vary with aquifer storage change caused by variable groundwater withdrawals, elevation change caused by aquifer compaction or expansion, and occasional recharge. In addition, continuous gravity records were collected for periods of several months using a super-conducting meter during 2010-2011 and using a spring-based gPhone meter during 2015-2016. The purpose of the continuous records was to provide more precise information about monthly and shorter period variations that could be related to variations in nearby groundwater withdrawals. The record of absolute gravity observations displays variations of as much as 35 microGal that correspond with local hydrologic variations documented from precipitation, streamflow, elevation, depths to water, and well pumping records. Depth to water in nearby wells display variations related to occasional local heavy precipitation events, runoff, recharge, and groundwater withdrawals. Increases in gravity that occur over periods of several months or longer correspond with occasional heavy precipitation and recharge. Periods of gravity decline occur during extended periods between recharge events and periods of increased local groundwater withdrawals. Analysis of the continuous records from both instruments indicate that groundwater drains slowly from storage in response to pumping variations, requiring several days or longer for the aquifer to drain, which is consistent with other hydrologic records.

  3. Direct reading inductance meter

    NASA Technical Reports Server (NTRS)

    Kolby, R. B. (Inventor)

    1977-01-01

    A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.

  4. Gamma radiation field intensity meter

    DOEpatents

    Thacker, Louis H.

    1994-01-01

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  5. Gamma radiation field intensity meter

    DOEpatents

    Thacker, Louis H.

    1995-01-01

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

  6. The smart meter and a smarter consumer: quantifying the benefits of smart meter implementation in the United States

    PubMed Central

    2012-01-01

    The electric grid in the United States has been suffering from underinvestment for years, and now faces pressing challenges from rising demand and deteriorating infrastructure. High congestion levels in transmission lines are greatly reducing the efficiency of electricity generation and distribution. In this paper, we assess the faults of the current electric grid and quantify the costs of maintaining the current system into the future. While the proposed “smart grid” contains many proposals to upgrade the ailing infrastructure of the electric grid, we argue that smart meter installation in each U.S. household will offer a significant reduction in peak demand on the current system. A smart meter is a device which monitors a household’s electricity consumption in real-time, and has the ability to display real-time pricing in each household. We conclude that these devices will provide short-term and long-term benefits to utilities and consumers. The smart meter will enable utilities to closely monitor electricity consumption in real-time, while also allowing households to adjust electricity consumption in response to real-time price adjustments. PMID:22540990

  7. Intravenous fluid flow meter concept for zero gravity environment

    NASA Technical Reports Server (NTRS)

    Miller, C. G.

    1972-01-01

    Measuring chamber, included in infusion-set tubing, and peristaltic flow meter concept can be incorporated into flow meter that measures fluid flow rates between 100 and 600 cu cm per hour and at the same time maintains sterilization.

  8. Visibility and spacing of lane control signals for freeway traffic management. Interim research report, September 1993-September 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullman, G.L.; Tallamraju, S.S.; Trout, N.D.

    1994-11-01

    Glance legibility studies conducted at the TTI Proving Grounds examined the legibility of three commercially available LCS with respect to symbol, signal type, subject gender, and subject age. Also, the effect of ambient light conditions was also explored. Symbols on all three signals resulted in median glance legibility distances of 304.8 meters (1000 feet) or greater, whereas the 85th percentile glance legibility distance was 213.4 meters (700 feet) or greater. Of the various factors examined, only the age of the subject significantly influenced legibility distances. In general, drivers 65 years and older had to be 91.5 to 198.1 meters (300more » to 650 feet) closer to the signals to correctly identify the symbols being displayed than drivers aged 16 to 44 years.« less

  9. Quantifying exchange between groundwater and surface water in rarely measured organic sediments

    NASA Astrophysics Data System (ADS)

    Rosenberry, D. O.; Cavas, M.; Keith, D.; Gefell, M. J.; Jones, P. M.

    2016-12-01

    Transfer of water and chemicals between poorly competent organic sediments and surface water in low-energy riverine and lentic settings depends on several factors, including rate and direction of flow, redox state, number and type of benthic invertebrates, and chemical gradients at and near the sediment-water interface. In spite of their commonly large areal extent, direct measurements of flow in soft, organic sediments are rarely made and little is known about flux direction, rate, or heterogeneity. Commonly used monitoring wells are difficult to install and suffer from slow response to changing hydraulic head due to the low permeability of these sediments. Seepage meters can directly quantify seepage flux if several challenges can be overcome. Meters are difficult to install and operate where water is deep, visibility is poor, and the position of the sediment-water interface is not readily apparent. Soft, easily eroded sediment can be displaced during meter installation, creating bypass flow beneath the bottom of the seepage cylinder. Poorly competent sediments often cannot support the weight of the meters; they slowly sink into the bed and displace water inside the seepage cylinder, which leads to the interpretation of large upward flow. Decaying organic material within the sediment generates gas that can displace water and corrupt seepage-meter measurements. Several inexpensive modifications to a standard seepage meter, as well as precautions during installation and operation, can minimize these sources of error. Underwater video cameras can be mounted to the meter to remotely observe sediment disturbance during sensor installation and monitor the stability of the meter insertion depth during the period of deployment. Anchor rods can be driven a meter or more into the sediment until refusal, firmly anchoring the seepage meter at a constant sediment insertion depth. Data collected from modified seepage meters installed in Minnesota and New York demonstrate the importance of quantifying flows in these challenging settings where biogeochemistry is complex and seepage rates commonly have been assumed to be insignificantly small.

  10. Gamma radiation field intensity meter

    DOEpatents

    Thacker, L.H.

    1995-10-17

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  11. Gamma radiation field intensity meter

    DOEpatents

    Thacker, L.H.

    1994-08-16

    A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

  12. In Situ Soil Venting - Full Scale Test, Hill AFB, Guidance Document. Volume 2

    DTIC Science & Technology

    1991-08-01

    oxidizer. Another system was connected to the existing air scrubber of a building (Reference 23). The self-contained unit reported by Rippberger...devices on the market for flow rate measurement. Some of the more common devices are orifice meters, venturi meters, rotameters, pitot tubes, hot-wire...Notes on how to size and construct orifice meters can be found in Reference 41. * Venturi Meter - A venturi meter works basically on the same

  13. Sedimentation survey of Lago Caonillas, Utuado, Puerto Rico, September–November 2012

    USGS Publications Warehouse

    Soler-Lopez, Luis R.

    2016-11-09

    During September–November 2012, the U.S. Geological Survey, in cooperation with the Puerto Rico Aqueduct and Sewer Authority, conducted a sedimentation survey of Lago Caonillas to estimate current (2012) reservoir storage capacity and the recent (2000–2012) reservoir sedimentation rate by comparing the 2012 bathymetric survey data with the February 2000 data. The Lago Caonillas storage capacity, which was 42.27 million cubic meters in February 2000, decreased to 39.55 million cubic meters by September–November 2012. The intersurvey (2000–2012) storage capacity loss was about 6 percent, corresponding to a decrease of about 0.5 percent per year; this loss represents a reservoir sedimentation rate of about 226,670 cubic meters per year between 2000 and 2012. On a long-term basis, however, the sedimentation rate has remained nearly constant, decreasing from about 257,500 to 251,720 cubic meters per year during 1948–2000 and 1948–2012, respectively. Most of the sediment accumulation and associated storage capacity loss of Lago Caonillas has occurred within the eastern and Río Caonillas branches of the reservoir. In the vicinity of the Caonillas Dam, minor sediment deposition and scour have occurred. The Lago Caonillas drainage area sediment yield has decreased by about 2 percent since the previous survey, from 1,266 cubic meters per square kilometer per year in 2000 to 1,237 cubic meters per square kilometer per year in 2012. If the long-term sedimentation rate of 251,720 cubic meters per year remains constant, the useful life of Lago Caonillas may end in about 2169.

  14. Fuel supply device for supplying fuel to an engine combustor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindsay, M.H.; Kerr, W.B.

    1990-05-29

    This patent describes a variable flow rate fuel supply device for supplying fuel to an engine combustor. It comprises: fuel metering means having a fuel valve means for controlling the flow rate of fuel to the combustor; piston means for dividing a first cooling fluid chamber from a second cooling fluid chamber; coupling means for coupling the piston means to the fuel valve means; and cooling fluid supply means in communication with the first and second cooling fluid chamber for producing a first pressure differential across the piston means for actuating the fuel valve means in a first direction, andmore » for producing a second pressure differential across the piston means for actuating the valve means in a second direction opposite the first direction, to control the flow rate of the fuel through the fuel metering means and into the engine combustor; and means for positioning the fuel metering means within the second cooling air chamber enabling the cooling air supply means to both cool the fuel metering means and control the fuel supply rate of fuel supplied by the fuel metering means to the combustor.« less

  15. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Energy and Resources Group, University of California, Berkeley; Darghouth, Naim R.; Barbose, Galen

    2011-06-01

    Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers inmore » the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.« less

  16. 20-meter underwater wireless optical communication link with 1.5 Gbps data rate.

    PubMed

    Shen, Chao; Guo, Yujian; Oubei, Hassan M; Ng, Tien Khee; Liu, Guangyu; Park, Ki-Hong; Ho, Kang-Ting; Alouini, Mohamed-Slim; Ooi, Boon S

    2016-10-31

    The video streaming, data transmission, and remote control in underwater call for high speed (Gbps) communication link with a long channel length (~10 meters). We present a compact and low power consumption underwater wireless optical communication (UWOC) system utilizing a 450-nm laser diode (LD) and a Si avalanche photodetector. With the LD operating at a driving current of 80 mA with an optical power of 51.3 mW, we demonstrated a high-speed UWOC link offering a data rate up to 2 Gbps over a 12-meter-long, and 1.5 Gbps over a record 20-meter-long underwater channel. The measured bit-error rate (BER) are 2.8 × 10-5, and 3.0 × 10-3, respectively, which pass well the forward error correction (FEC) criterion.

  17. Measuring Pulse Rate Variability using Long-Range, Non-Contact Imaging Photoplethysmography

    DTIC Science & Technology

    2016-08-20

    subject distances. In this study, video was recorded from 19 participants, while at rest, at a distance of 25 meters from the imaging sensor. A...subject distances of no more than 3 meters . This study demonstrates that pulse rates of less than one beat-per-minute error can be obtained when the...be achieved at long imager-to-subject distances. In this study, video was recorded from 19 participants, while at rest, at a distance of 25 meters

  18. Icing Characteristics of Low Altitude, Supercooled Layer Clouds. Revision

    DTIC Science & Technology

    1980-05-01

    Droplet Size Distribution 5. Icing Rate Meters C. Accuracy and Sources of Error in the Measurements from the Period 1944-1950 11 1. Rotating...whether currently available LWC meters and icing rate detectors will give re- liable results when flown on helicopters. Concerning the forecasting...Max Dia. Size Distrib. Meter Samples 4 1944 MSP DP -- Al .... 4 6 1946 OR 2,4RC 2,4RHC Al 4RMC -- 3 7 1946-47 NEMO, 4RMC 4RMC AI 4RMC - 31 TN,OH, IN

  19. Linear-log counting-rate meter uses transconductance characteristics of a silicon planar transistor

    NASA Technical Reports Server (NTRS)

    Eichholz, J. J.

    1969-01-01

    Counting rate meter compresses a wide range of data values, or decades of current. Silicon planar transistor, operating in the zero collector-base voltage mode, is used as a feedback element in an operational amplifier to obtain the log response.

  20. A tube seepage meter for in situ measurement of seepage rate and groundwater sampling

    USGS Publications Warehouse

    Solder, John; Gilmore, Troy E.; Genereux, David P.; Solomon, D. Kip

    2016-01-01

    We designed and evaluated a “tube seepage meter” for point measurements of vertical seepage rates (q), collecting groundwater samples, and estimating vertical hydraulic conductivity (K) in streambeds. Laboratory testing in artificial streambeds show that seepage rates from the tube seepage meter agreed well with expected values. Results of field testing of the tube seepage meter in a sandy-bottom stream with a mean seepage rate of about 0.5 m/day agreed well with Darcian estimates (vertical hydraulic conductivity times head gradient) when averaged over multiple measurements. The uncertainties in q and K were evaluated with a Monte Carlo method and are typically 20% and 60%, respectively, for field data, and depend on the magnitude of the hydraulic gradient and the uncertainty in head measurements. The primary advantages of the tube seepage meter are its small footprint, concurrent and colocated assessments of q and K, and that it can also be configured as a self-purging groundwater-sampling device.

  1. Virtual Titrator: A Student-Oriented Instrument.

    ERIC Educational Resources Information Center

    Ritter, David; Johnson, Michael

    1997-01-01

    Describes a titrator system, constructed from a computer-interfaced pH-meter, that was designed to increase student involvement in the process. Combines automatic data collection with real-time graphical display and interactive controls to focus attention on the process rather than on bits of data. Improves understanding of concepts and…

  2. Tactile Media for the Visually Handicapped.

    ERIC Educational Resources Information Center

    Diodato, Virgil

    New technological developments allow even the most severely visually handicapped person to read print, sense images, and operate calculators and meters. One of these new developments is the Optacon, which converts printed images to vibrations sensed by finger touch, and may be used to read print, handwriting, and calculator displays. Another…

  3. High fidelity, radiation tolerant analog-to-digital converters

    NASA Technical Reports Server (NTRS)

    Wang, Charles Chang-I (Inventor); Linscott, Ivan Richard (Inventor); Inan, Umran S. (Inventor)

    2012-01-01

    Techniques for an analog-to-digital converter (ADC) using pipeline architecture includes a linearization technique for a spurious-free dynamic range (SFDR) over 80 deciBels. In some embodiments, sampling rates exceed a megahertz. According to a second approach, a switched-capacitor circuit is configured for correct operation in a high radiation environment. In one embodiment, the combination yields high fidelity ADC (>88 deciBel SFDR) while sampling at 5 megahertz sampling rates and consuming <60 milliWatts. Furthermore, even though it is manufactured in a commercial 0.25-.mu.m CMOS technology (1 .mu.m=12.sup.-6 meters), it maintains this performance in harsh radiation environments. Specifically, the stated performance is sustained through a highest tested 2 megarad(Si) total dose, and the ADC displays no latchup up to a highest tested linear energy transfer of 63 million electron Volts square centimeters per milligram at elevated temperature (131 degrees C.) and supply (2.7 Volts, versus 2.5 Volts nominal).

  4. Heavy Cigarette Smokers in a Chinese Population Display a Compromised Permeability Barrier

    PubMed Central

    Xin, Shujun; Ye, Li; Lv, Chengzhi; Elias, Peter M.

    2016-01-01

    Cigarette smoking is associated with various cutaneous disorders with defective permeability. Yet, whether cigarette smoking influences epidermal permeability barrier function is largely unknown. Here, we measured skin biophysical properties, including permeability barrier homeostasis, stratum corneum (SC) integrity, SC hydration, skin surface pH, and skin melanin/erythema index, in cigarette smokers. A total of 99 male volunteers were enrolled in this study. Smokers were categorized as light-to-moderate (<20 cigarettes/day) or heavy smokers (≥20 cigarettes/day). An MPA5 was used to measure SC hydration and skin melanin/erythema index on the dorsal hand, forehead, and cheek. Basal transepidermal water loss (TEWL) and barrier recovery rates were assessed on the forearm. A Skin-pH-Meter pH900 was used to measure skin surface pH. Our results showed that heavy cigarette smokers exhibited delayed barrier recovery after acute abrogation (1.02% ± 13.06 versus 16.48% ± 6.07), and barrier recovery rates correlated negatively with the number of daily cigarettes consumption (p = 0.0087). Changes in biophysical parameters in cigarette smokers varied with body sites. In conclusion, heavy cigarette smokers display compromised permeability barrier homeostasis, which could contribute, in part, to the increased prevalence of certain cutaneous disorders characterized by defective permeability. Thus, improving epidermal permeability barrier should be considered for heavy cigarette smokers. PMID:27437403

  5. Surface Textures and Features Indicative of Endogenous Growth at the McCartys Flow Field, NM, as an Analog to Martian Volcanic Plains

    NASA Technical Reports Server (NTRS)

    Bleacher, Jacob E.; Crumpler, L. S.; Garry, W. B.; Zimbelman, J. R.; Self, S.; Aubele, J. C.

    2012-01-01

    Basaltic lavas typically form channels or tubes, which are recognized on the Earth and Mars. Although largely unrecognized in the planetary community, terrestrial inflated sheet flows also display morphologies that share many commonalities with lava plains on Mars. The McCartys lava flow field is among the youngest (approx.3000 yrs) basaltic flows in the continental United States. The southwest sections of the flow displays smooth, flat-topped plateaus with irregularly shaped pits and hummocky inter-plateau units that form a polygonal surface. Plateaus are typically elongate in map view, up to 20 m high and display lineations within the glassy crust. Lineated surfaces occasionally display small < 1m diameter lava coils. Lineations are generally straight and parallel each other, sometimes for over 100 meters. The boundaries between plateaus and depressions are also lineated and tilted to angles sometimes approaching vertical. Plateau-parallel cracks, sometimes containing squeeze-ups, mark the boundary between tilted crust and plateau. Some plateau depressions display level floors with hummocky surfaces, while some are bowl shaped with floors covered in broken lava slabs. The lower walls of pits sometimes display lateral, sagged lava wedges. Infrequently, pit floors display the upper portion of a tumulus from an older flow. In some places the surface crust has been disrupted forming a slabby texture. Slabs are typically on the scale of a meter or less across and no less than 7-10 cm thick. The slabs preserve the lineated textures of the undisturbed plateau crust. It appears that this style of terrain represents the emplacement of an extensive sheet that experiences inflation episodes within preferred regions where lateral spreading of the sheet is inhibited, thereby forming plateaus. Rough surfaces represent inflation-related disruption of pahoehoe lava and not a a lava. Depressions are often the result of non-inflation and can be clearly identified by lateral squeeze-outs along the pit walls that form when the rising crust exposes the still liquid core of the sheet. The plains of Tharsis and Elysium, Mars, display many analogous features

  6. Analysis of Vadose Hydrology at Jinapsan Cave, Guam, Mariana Islands

    NASA Astrophysics Data System (ADS)

    Bautista, K. K.; Jenson, J. W.; Lander, M.; Noronha, A. L.; Righetti, T.

    2016-12-01

    Six years of monthly data were analyzed from an active tropical limestone cave in Guam, the southernmost of the Mariana Islands, in the western Pacific Ocean. The purpose of this study was to characterize vadose processes of aquifer recharge in the Plio-Pleistocene Mariana Limestone, which occupies about 75% of the surface of the Northern Guam Lens Aquifer, which produces 90% of the island's drinking water. This hydrogeologic study was conducted concurrent with paleoclimate research, in which correlative data on CO2 and other cave meteorological parameters are also collected. For this study, a ground survey grid was established on the surface above the cave, a vegetated talus slope at the foot of the >150-m cliff in the Mariana Limestone behind the cave. Cave and vadose zone 3-D models were constructed from the surface survey and an interior cave survey. Cross sections display talus slope features (33°), notational talus grain size distribution, inferred epikarst and vadose layer dimensions, cave slope (-34°) and structural and geomorphic features of the cave, including a brackish sea-level pool at the cave bottom. GIS products include georeferenced cave boundary and cave room shapefiles. A plan-view map displays significant boulder talus and limestone forest trees, cave entrance location and the underlying cave boundary and fractures mapped on the cave ceiling. Thicknesses of the talus and vadose bedrock sections range from 1.3 to 17.0 meters and 1.7 to 46.4 meters, respectively. Drip rate and discharge rate data from 7 cave stations are presented in graphs showing varying responses between percolation and changes in rainfall during wet (Jul-Dec) and dry (Jan-Jun) seasons. Three stations exhibited fast responses to wet season rainfall, which gradually dropped during the dry season. Two of these stations are at separate cave ceiling fractures. The third is indiscernible from its distance (>4m) above the floor. Three stations exhibited slow responses in both wet and dry seasons, which may be attributed to matrix percolation. One station exhibited slow responses, except for three consecutive months of fast response, a probable effect of short-term pathway rerouting. One slow percolation station also showed a semi-diurnal pattern in its drip rate, which correlates with the atmospheric tidal signal.

  7. Nucleation and growth of the Naica giant gypsum crystals.

    PubMed

    Otálora, Fermín; García-Ruiz, JuanMa

    2014-04-07

    The Cave of Giant Crystals in the Naica mine (Mexico) is one of the most amazing displays of mineral beauty ever created in nature. In addition to the colossal crystals of gypsum, which in some cases exceed eleven meters in length and one meter in thickness, the scenery fashioned by the crystalline beams that thrust through the darkness of the cave from floor to ceiling with a luster like moonlight is a unique example of harmony based on crystal symmetry. We review the crystallogenesis of this remarkable and challenging phenomenon of mineralization near equilibrium that can be used to teach the basics of nucleation and crystal growth.

  8. Data system for multiplexed water-current meters

    NASA Technical Reports Server (NTRS)

    Ramsey, C. R.

    1977-01-01

    Flow rates at 32 flood plain locations are measured simultaneously by single digital logic unit with high noise immunity. Water flowing through pygmy current meters rotates element that closes electrical contact once every resolution, so flow rate is measured by counting number of closures in time interval.

  9. FibroMeters: a family of blood tests for liver fibrosis.

    PubMed

    Calès, P; Boursier, J; Oberti, F; Hubert, I; Gallois, Y; Rousselet, M-C; Dib, N; Moal, V; Macchi, L; Chevailler, A; Michalak, S; Hunault, G; Chaigneau, J; Sawadogo, A; Lunel, F

    2008-09-01

    FibroMeters are blood tests for liver fibrosis with several specificities: two main diagnostic targets (fibrosis stage and area of fibrosis); adaptation to specific causes; and results confirmed by an expert system. Thus, FibroMeters comprise six different tests: one for staging and one for quantitation of liver fibrosis in each of the three main causes of chronic liver disease-chronic viral hepatitis, alcoholic liver disease (ALD) and non-alcoholic fatty liver disease (NAFLD). FibroMeters display a high overall diagnostic accuracy and are the only tests to correctly classify 100% of HCV patients without fibrosis or with cirrhosis. They have 90% predictive values in a higher proportion of patients than with other usual blood tests. A 90% correct classification is available in 100% of HCV patients with the following reliable diagnostic intervals: F0/1, F1/2, F2+/-1, F3+/-1. In real-life conditions, the reproducibility of FibroMeters is higher than that of liver biopsy or ultrasonographic elastometry. FibroMeters are robust tests with the most stable diagnostic performance across different centers. Optional tests are also available, such as a specific one for cirrhosis, which has a diagnostic accuracy of 93.0% (AUROC: 0.92) and a 100% positive predictive value for diagnosis of HCV cirrhosis. Determination by FibroMeters of the area of fibrosis - the only direct, non-invasive, quantitative measurement of liver fibrosis - are especially useful for following-up cirrhosis as it correlates well with clinical events. FibroMeters are also very accurate in HVB or HIV-HCV co-infected patients. The tests specific for ALD and NAFLD also have a high diagnostic accuracy (AUROCs: 0.96 and 0.94, respectively, for significant fibrosis).

  10. 46 CFR 108.463 - Foam rate: Protein.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... least 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot) of area... rate at each outlet must be at least 4.07 liters per minute for each square meter (.1 gallon per minute for each square foot) of liquid surface in the tank. ...

  11. 46 CFR 108.463 - Foam rate: Protein.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... least 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot) of area... rate at each outlet must be at least 4.07 liters per minute for each square meter (.1 gallon per minute for each square foot) of liquid surface in the tank. ...

  12. 46 CFR 108.463 - Foam rate: Protein.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... least 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot) of area... rate at each outlet must be at least 4.07 liters per minute for each square meter (.1 gallon per minute for each square foot) of liquid surface in the tank. ...

  13. 46 CFR 108.463 - Foam rate: Protein.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... least 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot) of area... rate at each outlet must be at least 4.07 liters per minute for each square meter (.1 gallon per minute for each square foot) of liquid surface in the tank. ...

  14. 46 CFR 108.463 - Foam rate: Protein.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... least 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot) of area... rate at each outlet must be at least 4.07 liters per minute for each square meter (.1 gallon per minute for each square foot) of liquid surface in the tank. ...

  15. Impact of ground speed and varying seeding rates on meter performance

    USDA-ARS?s Scientific Manuscript database

    Achieving optimum planter performance is an important requirement for obtaining higher crop yields. Planter performance depends on several factors but meter speed is an important one which is a function of ground speed, seeding rate and row spacing. A study was conducted to evaluate the influence of...

  16. Intellectual Production Supervision Perform based on RFID Smart Electricity Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    This topic develops the RFID intelligent electricity meter production supervision project management system. The system is designed for energy meter production supervision in the management of the project schedule, quality and cost information management requirements in RFID intelligent power, and provide quantitative information more comprehensive, timely and accurate for supervision engineer and project manager management decisions, and to provide technical information for the product manufacturing stage file. From the angle of scheme analysis, design, implementation and test, the system development of production supervision project management system for RFID smart meter project is discussed. Focus on the development of the system, combined with the main business application and management mode at this stage, focuses on the energy meter to monitor progress information, quality information and cost based information on RFID intelligent power management function. The paper introduces the design scheme of the system, the overall client / server architecture, client oriented graphical user interface universal, complete the supervision of project management and interactive transaction information display, the server system of realizing the main program. The system is programmed with C# language and.NET operating environment, and the client and server platforms use Windows operating system, and the database server software uses Oracle. The overall platform supports mainstream information and standards and has good scalability.

  17. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    PubMed

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  18. Selected Hydrologic, Water-Quality, Biological, and Sedimentation Characteristics of Laguna Grande, Fajardo, Puerto Rico, March 2007-February 2009

    USGS Publications Warehouse

    Soler-López, Luis R.; Santos, Carlos R.

    2010-01-01

    Laguna Grande is a 50-hectare lagoon in the municipio of Fajardo, located in the northeasternmost part of Puerto Rico. Hydrologic, water-quality, and biological data were collected in the lagoon between March 2007 and February 2009 to establish baseline conditions and determine the health of Laguna Grande on the basis of preestablished standards. In addition, a core of bottom material was obtained at one site within the lagoon to establish sediment depositional rates. Water-quality properties measured onsite (temperature, pH, dissolved oxygen, specific conductance, and water transparency) varied temporally rather than areally. All physical properties were in compliance with current regulatory standards established for Puerto Rico. Nutrient concentrations were very low and in compliance with current regulatory standards (less than 5.0 and 1.0 milligrams per liter for total nitrogen and total phosphorus, respectively). The average total nitrogen concentration was 0.28 milligram per liter, and the average total phosphorus concentration was 0.02 milligram per liter. Chlorophyll a was the predominant form of photosynthetic pigment in the water. The average chlorophyll-a concentration was 6.2 micrograms per liter. Bottom sediment accumulation rates were determined in sediment cores by modeling the downcore activities of lead-210 and cesium-137. Results indicated a sediment depositional rate of about 0.44 centimeter per year. At this rate of sediment accretion, the lagoon may become a marshland in about 700 to 900 years. About 86 percent of the community primary productivity in Laguna Grande was generated by periphyton, primarily algal mats and seagrasses, and the remaining 14 percent was generated by phytoplankton in the water column. Based on the diel studies the total average net community productivity equaled 5.7 grams of oxygen per cubic meter per day (2.1 grams of carbon per cubic meter per day). Most of this productivity was ascribed to periphyton and macrophytes, which produced 4.9 grams of oxygen per cubic meter per day (1.8 grams of carbon per cubic meter per day). Phytoplankton, the plant and algal component of plankton, produced about 0.8 gram of oxygen per cubic meter per day (0.3 gram of carbon per cubic meter per day). The total diel community respiration rate was 23.4 grams of oxygen per cubic meter per day. The respiration rate ascribed to plankton, which consists of all free floating and swimming organisms in the water column, composed 10 percent of this rate (2.9 grams of oxygen per cubic meter per day); respiration by all other organisms composed the remaining 90 percent (20.5 grams of oxygen per cubic meter per day). Plankton gross productivity was 3.7 grams of oxygen per cubic meter per day, equivalent to about 13 percent of the average gross productivity for the entire community (29.1 grams of oxygen per cubic meter per day). The average phytoplankton biomass values in Laguna Grande ranged from 6.0 to 13.6 milligrams per liter. During the study, Laguna Grande contained a phytoplankton standing crop of approximately 5.8 metric tons. Phytoplankton community had a turnover (renewal) rate of about 153 times per year, or roughly about once every 2.5 days. Fecal indicator bacteria concentrations ranged from 160 to 60,000 colonies per 100 milliliters. Concentrations generally were greatest in areas near residential and commercial establishments, and frequently exceeded current regulatory standards established for Puerto Rico.

  19. An Investigation of Slurry Fuel Combustion.

    DTIC Science & Technology

    1981-01-01

    tit Lil’ sitas wtae f).4 mm ap.art. w w =Q L-1~ rAn Li w > 0 0- - q The propane gas flow rate was metered withi a Matlieson Model 604 rotameter and...controlled by a Harris Model 2515 pressure regulator with an output capacity of 0-0.69 MPa. The flow rate of the iydrog’en gas was metered with a...propane 3nd hydrogen flows were calibrated with a Precision Scientific Companv wet-test meter (2.83 ml/rev). The fuel drops were mounted with a

  20. Modeling Geyser Eruptions in the Classroom

    ERIC Educational Resources Information Center

    Mattox, Stephen; Webster, Christine

    2005-01-01

    Watching Old Faithful transform from a smoldering mound to an explosive 50-meter high geyser is enough to generate awe in any observer. Behind this stunning, visual geologic display is a triad of heat, water, and plumbing that rarely unify on our planet. But geologists are not the only scientists drawn to geysers. Biologists have recently…

  1. A cycle timer for testing electric vehicles

    NASA Technical Reports Server (NTRS)

    Soltis, R. F.

    1978-01-01

    A cycle timer was developed to assist the driver of an electric vehicle in more accurately following and repeating SAE driving schedules. These schedules require operating an electric vehicle in a selected stop-and-go driving cycle and repeating this cycle pattern until the vehicle ceases to meet the requirements of the cycle. The heart of the system is a programmable read-only memory (PROM) that has the required test profiles permanently recorded on plug-in cards, one card for each different driving schedule. The PROM generates a direct current analog signal that drives a speedometer displayed on one scale of a dual movement meter. The second scale of the dual movement meter displays the actual speed of the vehicle as recorded by the fifth wheel. The vehicle operator controls vehicle speed to match the desired profile speed. The PROM controls the recycle start time as well as the buzzer activation. The cycle programmer is powered by the test vehicle's 12-volt accessory battery, through a 5-volt regulator and a 12-volt dc-to-dc converter.

  2. Computer Programs to Display and Modify Data in Geographic Coordinates and Methods to Transfer Positions to and from Maps, with Applications to Gravity Data Processing, Global Positioning Systems, and 30-Meter Digital Elevation Models

    USGS Publications Warehouse

    Plouff, Donald

    1998-01-01

    Computer programs were written in the Fortran language to process and display gravity data with locations expressed in geographic coordinates. The programs and associated processes have been tested for gravity data in an area of about 125,000 square kilometers in northwest Nevada, southeast Oregon, and northeast California. This report discusses the geographic aspects of data processing. Utilization of the programs begins with application of a template (printed in PostScript format) to transfer locations obtained with Global Positioning Systems to and from field maps and includes a 5-digit geographic-based map naming convention for field maps. Computer programs, with source codes that can be copied, are used to display data values (printed in PostScript format) and data coverage, insert data into files, extract data from files, shift locations, test for redundancy, and organize data by map quadrangles. It is suggested that 30-meter Digital Elevation Models needed for gravity terrain corrections and other applications should be accessed in a file search by using the USGS 7.5-minute map name as a file name, for example, file '40117_B8.DEM' contains elevation data for the map with a southeast corner at lat 40? 07' 30' N. and lon 117? 52' 30' W.

  3. The Anti-RFI Design of Intelligent Electric Energy Meters with UHF RFID

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    In order to solve the existing artificial meter reading watt-hour meter industry is still slow and inventory of common problems, using the uhf radio frequency identification (RFID) technology and intelligent watt-hour meter depth fusion, which has a one-time read multiple tags, identification distance, high transmission rate, high reliability, etc, while retaining the original asset management functions, in order to ensure the uhf RFID and minimum impact on the operation of the intelligent watt-hour meter, proposed to improve the stability of the electric meter system while working at the same time, this paper designs the uhf RFID intelligent watt-hour meter radio frequency interference resistance, put forward to improve intelligent watt-hour meter electromagnetic compatibility design train of thought, and introduced its power and the hardware circuit design of printed circuit board, etc.

  4. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darghouth, Naim; Barbose, Galen; Wiser, Ryan

    2010-03-30

    Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods aremore » under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.« less

  5. Robust, non-invasive methods for metering groundwater well extraction in remote environments

    NASA Astrophysics Data System (ADS)

    Bulovic, Nevenka; Keir, Greg; McIntyre, Neil

    2017-04-01

    Quantifying the rate of extraction from groundwater wells can be essential for regional scale groundwater management and impact assessment. This is especially the case in regions heavily dependent on groundwater such as the semi-arid Surat and Bowen Basins in Queensland, Australia. Of the 30 000+ groundwater wells in this area, the majority of which are used for stock watering and domestic purposes, almost none have flow metering devices installed. As part of a research project to estimate regional groundwater extraction, we have undertaken a small scale flow metering program on a selected set of wells. Conventional in-line flow meters were unsuitable for our project, as both non-invasiveness and adaptability / suitability to a variety of discharge pipe characteristics was critical. We describe the use of two metering technologies not widely used in groundwater applications, non-invasive, clamp-on ultrasonic transit time flow meters and tipping bucket flow meters, as semi-permanent installations on discharge pipes of various artesian and sub-artesian groundwater wells. We present examples of detailed extraction rate time-series, which are of particular value in developing predictive models of water well extraction in data limited areas where water use dynamics and drivers are poorly understood. We conclude by discussing future project trajectories, which include expansion of the monitoring network through development of novel metering techniques and telemetry across large areas of poor connectivity.

  6. Far-Infrared Photometry with an 0.4-Meter Liquid Helium Cooled Balloon-Borne Telescope. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Jacobson, M. R.

    1977-01-01

    A 0.4-meter aperture, liquid helium cooled multichannel far-infrared balloon-borne telescope was constructed to survey the galactic plane. Nine new sources, above a 3-sigma confidence level of 1300 Jy, were identified. Although two-thirds of the scanned area was more than 10 degrees from the galactic plane, no sources were detected in that region; all nine fell within 10 degrees and eight of those within 4 degrees of the galactic equator. Correlations with visible, compact H lines associated with radio continuum and with sources displaying spectra steeply rising between 11 and 20 microns were noted, while stellar objects were not detected.

  7. Research on the calibration methods of the luminance parameter of radiation luminance meters

    NASA Astrophysics Data System (ADS)

    Cheng, Weihai; Huang, Biyong; Lin, Fangsheng; Li, Tiecheng; Yin, Dejin; Lai, Lei

    2017-10-01

    This paper introduces standard diffusion reflection white plate method and integrating sphere standard luminance source method to calibrate the luminance parameter. The paper compares the effects of calibration results by using these two methods through principle analysis and experimental verification. After using two methods to calibrate the same radiation luminance meter, the data obtained verifies the testing results of the two methods are both reliable. The results show that the display value using standard white plate method has fewer errors and better reproducibility. However, standard luminance source method is more convenient and suitable for on-site calibration. Moreover, standard luminance source method has wider range and can test the linear performance of the instruments.

  8. Water leakage management by district metered areas at water distribution networks.

    PubMed

    Özdemir, Özgür

    2018-03-01

    The aim of this study is to design a district metered area (DMA) at water distribution network (WDN) for determination and reduction of water losses in the city of Malatya, Turkey. In the application area, a pilot DMA zone was built by analyzing the existing WDN, topographic map, length of pipes, number of customers, service connections, and valves. In the DMA, International Water Association standard water balance was calculated considering inflow rates and billing records. The ratio of water losses in DMAs was determined as 82%. Moreover, 3124 water meters of 2805 customers were examined while 50% of water meters were detected as faulty. This study revealed that DMA application is useful for the determination of water loss rate in WDNs and identify a cost-effective leakage reduction program.

  9. 46 CFR 108.489 - Helicopter fueling facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...

  10. 46 CFR 108.489 - Helicopter fueling facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...

  11. 46 CFR 108.489 - Helicopter fueling facilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...

  12. 46 CFR 108.489 - Helicopter fueling facilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...

  13. 46 CFR 108.489 - Helicopter fueling facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the rate of 6.52 liters per minute for each square meter (.16 gallons per minute for each square foot... for each square meter (.1 gallon per minute for each square foot) of area covered for five minutes. (3....87 square meters (300 square feet). (b) If the fire protection system required by § 108.487 of this...

  14. Sandwave Morphologies and Dynamics in a Continental Shelf Environment : Example of the Banc du Four (western Brittany, France)

    NASA Astrophysics Data System (ADS)

    Franzetti, M.; Garlan, T.; Le Roy, P.; Delacourt, C.; Cancouët, R.; Graindorge, D.; Deschamps, A.

    2011-12-01

    Marine sand dunes and sandbanks are mainly observed in continental tidal shelves (North Sea, South China Sea, North Atlantic America) and may be highly dynamic (for example up to 75 m/y in the Marsdiep inlet). So they may pose a potential risk to offshore installations and shipping. Multitemporal mapping of sandwaves, necessary to mitigate this hazard, is complicated by their dynamic character, which is still poorly understood especially in the offshore domain. In consequence, these structures are often defined as moribund at depths greater than 30 meters. The aim of this investigation is to study evolution of deeper (110 meters) complex set of sand bedforms : "Banc du Four" located in the Iroise Sea. The study area is exposed to strong tidal currents and storm waves at the junction of the Northeast Atlantic Ocean and the Western English Channel, conditions favorable to sediment dynamics. The bathymetric data, which form the basis of this study, are two Digital Terrain Modeling's (DTM's) derived from MultiBeam Echosounder (MBES) surveys : "Pourquoi-Pas?" oceanographic research vessel (R/V) in February 2009 (5 meters resolution DTM) and R/V "Albert Lucas" in August 2010 (2 meters resolution DTM). Sandwave parameters (water depth, shape, wavelength, height, symmetry index, ...) have been derived from the 2009 bathymetric data. The Banc du Four is characterized by a large sandbank (45 meters height and 2 km width) flanked by dune fields. The morphological characteristics of the dunes vary greatly (range 30 to 110 meters depth, 40 meters maximal height, 600 meters maximal width, symmetrical to asymmetrical, ...). However, this complexity can be explained by the involved sandwave dynamic (range 0 to 30 meters per year migration velocity). Spatial correlation method, applied on the two DTM's, are used to measure the migration rate. The high migration rates for deeper giant dunes bring to light the dynamic sandwave existence at depths exceeding 30-40 meters, contrary to previously accepted models. Dune asymmetry is proportional to migration rates and the lee side is always oriented towards the direction of movement. These relationships confirm the observations reported in the literature for shallower structures.

  15. Alternative Fuels Data Center

    Science.gov Websites

    -of-Use rates are available in two variations: EV-TOU-2 bills home and vehicle electricity use on a single meter; and EV-TOU bills vehicle electricity use separately, requiring the installation of a second meter. Lower rates are also available to customers who own a natural gas vehicle and use a qualified

  16. Research on data collection key technology of smart electric energy meters

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; Chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Mouhailiu; Renheng, Xu

    2018-02-01

    In recent years, smart electric energy meters are demand at 70 million to 90 million with the strong smart grid construction every year in China. However, there are some issues in smart electric energy meters data collection such as the interference of environment, low collection efficiency and inability to work when the power is off. In order to solve these issues above, it uses the RFID communication technology to collect the numbers and electric energy information of smart electric energy meters on the basis of the existing smart electric energy meters, and the related data collection communication experiments were made. The experimental result shows that the electric information and other data batch collection of RFID smart electric energy meters are realized in power and power off. It improves the efficiency and the overall success rate is 99.2% within 2 meters. It provides a new method for smart electric energy meters data collection.

  17. Low flow vortex shedding flowmeter

    NASA Technical Reports Server (NTRS)

    Waugaman, Charles J.

    1989-01-01

    The purpose was to continue a development project on a no moving parts vortex shedding flowmeter used for flow measurement of hypergols. The project involved the design and construction of a test loop to evaluate the meter for flow of Freon which simulates the hypergol fluids. Results were obtained on the output frequency characteristics of the flow meter as a function of flow rate. A family of flow meters for larger size lines and ranges of flow was sized based on the results of the tested meter.

  18. Psychophysical contrast calibration

    PubMed Central

    To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli

    2013-01-01

    Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843

  19. The Quiet Classroom Game: A Class-Wide Intervention to Increase Academic Engagement and Reduce Disruptive Behavior

    ERIC Educational Resources Information Center

    Radley, Keith C.; Dart, Evan H.; O'Handley, Roderick D.

    2016-01-01

    The current study investigated the effectiveness of the Quiet Classroom Game, an interdependent group contingency using an iPad loaded with a decibel meter app, for increasing academically engaged behavior. Three first-grade classrooms in the southeastern United States, identified as displaying high levels of noise and disruptive behavior, were…

  20. 76 FR 27956 - Airworthiness Directives; Eurocopter Deutschland Model EC135 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... past, the FADEC FAIL caution light illuminated on a few EC135 T1 helicopters. They state that this was... transmitted to the FADEC. This discrepancy led to the display of the FADEC FAIL caution light and ``freezing... to automatically meter fuel, indicated by a FADEC FAIL cockpit caution light, and subsequent loss of...

  1. ChemDuino: Adapting Arduino for Low-Cost Chemical Measurements in Lecture and Laboratory

    ERIC Educational Resources Information Center

    Kubínova´, S?te?pa´nka; S?le´gr, Jan

    2015-01-01

    In everyday praxis, we often need demonstration measuring devices (thermometers, pH meters, etc.), with large enough displays to be easily readable from every point in the classroom. Here, we present some of the capabilities of the Arduino platform for the school environment. This microprocessor board can be used for inexpensive construction of…

  2. State of Texas - Highlighting low-lying areas derived from USGS Digital Elevation Data

    USGS Publications Warehouse

    Kosovich, John J.

    2008-01-01

    In support of U.S. Geological Survey (USGS) disaster preparedness efforts, this map depicts a color shaded relief representation of Texas and a grayscale relief of the surrounding areas. The first 30 feet of relief above mean sea level are displayed as brightly colored 5-foot elevation bands, which highlight low-elevation areas at a coarse spatial resolution. Standard USGS National Elevation Dataset (NED) 1 arc-second (nominally 30-meter) digital elevation model (DEM) data are the basis for the map, which is designed to be used at a broad scale and for informational purposes only. The NED data were derived from the original 1:24,000-scale USGS topographic map bare-earth contours, which were converted into gridded quadrangle-based DEM tiles at a constant post spacing (grid cell size) of either 30 meters (data before the mid-1990s) or 10 meters (mid-1990s and later data). These individual-quadrangle DEMs were then converted to spherical coordinates (latitude/longitude decimal degrees) and edge-matched to ensure seamlessness. The NED source data for this map consists of a mixture of 30-meter- and 10-meter-resolution DEMs. State and county boundary, hydrography, city, and road layers were modified from USGS National Atlas data downloaded in 2003. The NED data were downloaded in 2002. Shaded relief over Mexico was obtained from the USGS National Atlas.

  3. Low-cost chlorophyll meter (LCCM): portable measuring device for leaf chlorophyll

    NASA Astrophysics Data System (ADS)

    Hutomo E. P., Evan; Adibawa, Marcelinus Alfasisurya S.; Prilianti, Kestrilia R.; Heriyanto, Heriyanto; Brotosudarmo, Tatas H. P.

    2016-11-01

    Portable leaf chlorophyll meter, named low-cost chlorophyll meter (LCCM), has been created. This device was created to help farmer determining the health condition of plant based on the greenness level of leaf surface. According to previous studies, leaf greenness with a certain amount of chlorophyll level has a direct correlation with the amount of nitrogen in the leaf that indicates health of the plant and this fact needed to provide an estimate of further measures to keep the plants healthy. Device that enables to measure the leaf color change is soil plant analysis development (SPAD) meter 502 from Konica Minolta but it is relatively expensive. To answer the need of low-cost chlorophyll scanner device, this research conducted experiment using light reflectance as the base mechanism. Reflectance system from LCCM consists of near-infrared light emitting diode (LED) and red LED as light resources and photodiode. The output from both of light resources calculated using normalized difference vegetation index (NDVI) formula as the results fetched and displayed on the smartphone application using Bluetooth communication protocol. Finally, the scanner has been made as well as the Android application named NDVI Reader. The LCCM system which has been tested on 20 sample of cassava leaf with SPAD meter as a variable control showed coefficient of determination 0.9681 and root-mean-square error (RMSE) 0.014.

  4. The bacterial contamination rate of glucose meter test strips in the hospital setting

    PubMed Central

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  5. Balanced Flow Metering and Conditioning: Technology for Fluid Systems

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R.

    2006-01-01

    Revolutionary new technology that creates balanced conditions across the face of a multi-hole orifice plate has been developed, patented and exclusively licensed for commercialization. This balanced flow technology simultaneously measures mass flow rate, volumetric flow rate, and fluid density with little or no straight pipe run requirements. Initially, the balanced plate was a drop in replacement for a traditional orifice plate, but testing revealed substantially better performance as compared to the orifice plate such as, 10 times better accuracy, 2 times faster (shorter distance) pressure recovery, 15 times less acoustic noise energy generation, and 2.5 times less permanent pressure loss. During 2004 testing at MSFC, testing revealed several configurations of the balanced flow meter that match the accuracy of Venturi meters while having only slightly more permanent pressure loss. However, the balanced meter only requires a 0.25 inch plate and has no upstream or downstream straight pipe requirements. As a fluid conditioning device, the fluid usually reaches fully developed flow within 1 pipe diameter of the balanced conditioning plate. This paper will describe the basic balanced flow metering technology, provide performance details generated by testing to date and provide implementation details along with calculations required for differing degrees of flow metering accuracy.

  6. American Recovery and Reinvestment Act of 2009. Experiences from the Consumer Behavior Studies on Engaging Customers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappers, Peter; Scheer, Richard

    2014-09-01

    One of the most important aspects for the successful implementation of customer-facing programs is to better understand how to engage and communicate with consumers. Customer-facing programs include time-based rates, information and feedback, load management, and energy efficiency. This report presents lessons learned by utilities through consumer behavior studies (CBS) conducted as part of the Department of Energy’s (DOE) Smart Grid Investment Grant (SGIG) program. The SGIG CBS effort presents a unique opportunity to advance the understanding of consumer behaviors in terms of customer acceptance and retention, and electricity consumption and peak demand impacts. The effort includes eleven comprehensive studies withmore » the aim of evaluating the response of residential and small commercial customers to time-based rate programs implemented in conjunction with advanced metering infrastructure and customer systems such as in-home displays, programmable communicating thermostats, and web portals. DOE set guidelines and protocols that sought to help the utilities design studies that would rigorously test and more precisely estimate the impact of time-based rates on customers’ energy usage patterns, as well as identify the key drivers that motivate behavioral changes.« less

  7. Deep Space Network Antenna Logic Controller

    NASA Technical Reports Server (NTRS)

    Ahlstrom, Harlow; Morgan, Scott; Hames, Peter; Strain, Martha; Owen, Christopher; Shimizu, Kenneth; Wilson, Karen; Shaller, David; Doktomomtaz, Said; Leung, Patrick

    2007-01-01

    The Antenna Logic Controller (ALC) software controls and monitors the motion control equipment of the 4,000-metric-ton structure of the Deep Space Network 70-meter antenna. This program coordinates the control of 42 hydraulic pumps, while monitoring several interlocks for personnel and equipment safety. Remote operation of the ALC runs via the Antenna Monitor & Control (AMC) computer, which orchestrates the tracking functions of the entire antenna. This software provides a graphical user interface for local control, monitoring, and identification of faults as well as, at a high level, providing for the digital control of the axis brakes so that the servo of the AMC may control the motion of the antenna. Specific functions of the ALC also include routines for startup in cold weather, controlled shutdown for both normal and fault situations, and pump switching on failure. The increased monitoring, the ability to trend key performance characteristics, the improved fault detection and recovery, the centralization of all control at a single panel, and the simplification of the user interface have all reduced the required workforce to run 70-meter antennas. The ALC also increases the antenna availability by reducing the time required to start up the antenna, to diagnose faults, and by providing additional insight into the performance of key parameters that aid in preventive maintenance to avoid key element failure. The ALC User Display (AUD) is a graphical user interface with hierarchical display structure, which provides high-level status information to the operation of the ALC, as well as detailed information for virtually all aspects of the ALC via drill-down displays. The operational status of an item, be it a function or assembly, is shown in the higher-level display. By pressing the item on the display screen, a new screen opens to show more detail of the function/assembly. Navigation tools and the map button allow immediate access to all screens.

  8. A common fluence threshold for first positive and second positive phototropism in Arabidopsis thaliana

    NASA Technical Reports Server (NTRS)

    Janoudi, A.; Poff, K. L.

    1990-01-01

    The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 x 10(-5) to 6.5 x 10(-3) micromoles per square meter per second. The threshold values in the fluence rate-response curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system.

  9. Coordination and propulsion and non-propulsion phases in 100 meter breaststroke swimming.

    PubMed

    Strzała, Marek; Krężałek, Piotr; Kucia-Czyszczoń, Katarzyna; Ostrowski, Andrzej; Stanula, Arkadiusz; Tyka, Anna K; Sagalara, Andrzej

    2014-01-01

    The main purpose of this study was to analyze the coordination, propulsion and non-propulsion phases in the 100 meter breaststroke race. Twenty-seven male swimmers (15.7 ± 1.98 years old) with the total body length (TBL) of 247.0 ± 10.60 [cm] performed an all-out 100 m breaststroke bout. The bouts were recorded with an underwater camera installed on a portable trolley. The swimming kinematic parameters, stroke rate (SR) and stroke length (SL), as well as the coordination indices based on propulsive or non-propulsive movement phases of the arms and legs were distinguished. Swimming speed (V100surface breast) was associated with SL (R = 0.41, p < 0.05) and with TBL tending towards statistical significance (R = 0.36, p < 0.07), all relationships between the selected variables in the study were measured using partial correlations with controlled age. SL interplayed negatively with the limbs propulsive phase Overlap indicator (R = -0.46, p < 0.05), but had no significant relationship to the non-propulsion Glide indicator. The propulsion in-sweep (AP3) phase of arms and their non-propulsion partial air recovery (ARair) phase interplayed with V100surface breast (R = 0.51, p < 0.05 and 0.48 p < 0.05) respectively, displaying the importance of proper execution of this phase (AP3) and in reducing the resistance recovery phases in consecutive ones.

  10. The pricing of water in a university town: An economic analysis of draining a cash cow

    NASA Astrophysics Data System (ADS)

    Joyce, B. Patrick; Merz, Thomas E.

    1994-10-01

    This paper analyzes some economic issues involved with the common practice of using metered water rate revenue to fund debt retirement associated with the provision of municipal water and wastewater services. We conclude that rather than simply raising the metered rate, city officials should seriously consider increasing the tax rate levied under the local property tax. There is an important trade-off in the choice of a price policy. An increased property tax rate can result in tax savings to some home owners, which lowers their net expenditure for water. However, a corresponding decrease in the metered rate may increase water consumption, which in turn raises operating cost. In order to do what is best for home owners, it might make sense to give other customers (e.g., a university) an easy ride, even if the latter, because of its low (inelastic) price elasticity of demand for water, is viewed by the municipality as a cash cow.

  11. A system for calibrating seepage meters used to measure flow between ground water and surface water

    USGS Publications Warehouse

    Rosenberry, Donald O.; Menheer, Michael A.

    2006-01-01

    The in-line flowmeter used with this system is incapable of measuring seepage rates below about 7 centimeters per day. Smaller seepage rates can be measured manually. The seepage- control system also can be modified for measuring slower seepage rates with the use of two flowmeters and a slightly different water-routing system, or a fluid-metering pump can be used to control flow through the flux tank instead of an adjustable-height reservoir.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darghouth, Naïm R.; Wiser, Ryan; Barbose, Galen

    The substantial increase in deployment of customer-sited solar photovoltaics (PV) in the United States has been driven by a combination of steeply declining costs, financing innovations, and supportive policies. Among those supportive policies is net metering, which in most states effectively allows customers to receive compensation for distributed PV generation at the full retail electricity price. The current design of retail electricity rates and the presence of net metering have elicited concerns that the possible under-recovery of fixed utility costs from PV system owners may lead to a feedback loop of increasing retail prices that accelerate PV adoption and furthermore » rate increases. However, a separate and opposing feedback loop could offset this effect: increased PV deployment may lead to a shift in the timing of peak-period electricity prices that could reduce the bill savings received under net metering where time-varying retail electricity rates are used, thereby dampening further PV adoption. In this paper, we examine the impacts of these two competing feedback dynamics on U.S. distributed PV deployment through 2050 for both residential and commercial customers, across states. Our results indicate that, at the aggregate national level, the two feedback effects nearly offset one another and therefore produce a modest net effect, although their magnitude and direction vary by customer segment and by state. We also model aggregate PV deployment trends under various rate designs and net-metering rules, accounting for feedback dynamics. Our results demonstrate that future adoption of distributed PV is highly sensitive to retail rate structures. Whereas flat, time-invariant rates with net metering lead to higher aggregate national deployment levels than the current mix of rate structures (+5% in 2050), rate structures with higher monthly fixed customer charges or PV compensation at levels lower than the full retail rate can dramatically erode aggregate customer adoption of PV (from -14% to -61%, depending on the design). Moving towards time-varying rates, on the other hand, may accelerate near- and medium-term deployment (through 2030), but is found to slow adoption in the longer term (-22% in 2050).« less

  13. Apollo 16/AS-511/LM-11 operational calibration curves. Volume 1: Calibration curves for command service module CSM 113

    NASA Technical Reports Server (NTRS)

    Demoss, J. F. (Compiler)

    1971-01-01

    Calibration curves for the Apollo 16 command service module pulse code modulation downlink and onboard display are presented. Subjects discussed are: (1) measurement calibration curve format, (2) measurement identification, (3) multi-mode calibration data summary, (4) pulse code modulation bilevel events listing, and (5) calibration curves for instrumentation downlink and meter link.

  14. Aesthetic appreciation of poetry correlates with ease of processing in event-related potentials.

    PubMed

    Obermeier, Christian; Kotz, Sonja A; Jessen, Sarah; Raettig, Tim; von Koppenfels, Martin; Menninghaus, Winfried

    2016-04-01

    Rhetorical theory suggests that rhythmic and metrical features of language substantially contribute to persuading, moving, and pleasing an audience. A potential explanation of these effects is offered by "cognitive fluency theory," which stipulates that recurring patterns (e.g., meter) enhance perceptual fluency and can lead to greater aesthetic appreciation. In this article, we explore these two assertions by investigating the effects of meter and rhyme in the reception of poetry by means of event-related brain potentials (ERPs). Participants listened to four versions of lyrical stanzas that varied in terms of meter and rhyme, and rated the stanzas for rhythmicity and aesthetic liking. The behavioral and ERP results were in accord with enhanced liking and rhythmicity ratings for metered and rhyming stanzas. The metered and rhyming stanzas elicited smaller N400/P600 ERP responses than their nonmetered, nonrhyming, or nonmetered and nonrhyming counterparts. In addition, the N400 and P600 effects for the lyrical stanzas correlated with aesthetic liking effects (metered-nonmetered), implying that modulation of the N400 and P600 has a direct bearing on the aesthetic appreciation of lyrical stanzas. We suggest that these effects are indicative of perceptual-fluency-enhanced aesthetic liking, as postulated by cognitive fluency theory.

  15. The AGS Ggamma Meter and Calibrating the Gauss Clock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahrens, Leif

    2014-03-31

    During AGS Polarized Proton acceleration periods, one output from the AGS Ggamma Meter, namely the energy (or Ggamma) calculated from the magnetic field in the AGS main magnets and the beam radius- both measured in particular instant, is used to figure out the times in the AGS magnet acceleration cycle when the beam passes through a particular set of depolarizing resonances. The resonance set occur whenever a particle’s Ggamma (energy*(G/m) becomes nearly equal to n*Qx (i.e. any integer multiplied by the horizontal betatron tune). This deliverable is why the machinery is referred to as the ''Ggamma Meter'' rather than themore » AGS energy meter. The Ggamma Meter takes as inputs a set of measurements of frequency (F(t)), radius (r(t)), and gauss clock counts (GCC(t)). The other energy (GgammaBr) assumes the field when the gauss clock starts counting is known. The change in field to time t is given by the measured accumulated gauss clock counts multiplied by the gauss clock calibration (gauss/GCC). In order to deal with experimental data, this calibration factor gets an added ad hoc complication, namely a correction dependent on the rate of change the counting rate. The Ggamma meter takes GCC(t) and together with the past history for this cycle calculates B(t).« less

  16. Trajectory control sensor engineering model detailed test objective

    NASA Technical Reports Server (NTRS)

    Dekome, Kent; Barr, Joseph Martin

    1991-01-01

    The concept employed in an existing Trajectory Control Sensor (TCS) breadboard is being developed into an engineering model to be considered for flight on the Shuttle as a Detailed Test Objective (DTO). The sensor design addresses the needs of Shuttle/SSF docking/berthing by providing relative range and range rate to 1500 meters as well as the perceived needs of AR&C by relative attitude measurement over the last 100 meters. Range measurement is determined using a four-tone ranging technique. The Doppler shift on the highest frequency tone will be used to provide direct measurement of range rate. Bearing rate and attitude rates will be determined through back differencing of bearing and attitude, respectively. The target consists of an isosceles triangle configuration of three optical retroreflectors, roughly one meter and one-half meter in size. After target acquisition, the sensor continually updates the positions of the three retros at a rate of about one hertz. The engineering model is expected to weigh about 25 pounds, consume 25-30 watts, and have an envelope of about 1.25 cubic feet. The following concerns were addressed during the presentation: are there any concerns with differentiating attitude and bearing to get attitude and bearing rates? Since the docking scenario has low data bandwidth, back differencing is a sufficient approximation of a perfect differentiator for this application. Could range data be obtained if there were no retroreflectors on the target vehicle? Possibly, but only at close range. It would be dependent on target characteristics.

  17. Gulf of Mexico region - Highlighting low-lying areas derived from USGS Digital Elevation Data

    USGS Publications Warehouse

    Kosovich, John J.

    2008-01-01

    In support of U.S. Geological Survey (USGS) disaster preparedness efforts, this map depicts a color shaded relief representation of the area surrounding the Gulf of Mexico. The first 30 feet of relief above mean sea level are displayed as brightly colored 5-foot elevation bands, which highlight low-elevation areas at a coarse spatial resolution. Standard USGS National Elevation Dataset (NED) 1 arc-second (nominally 30-meter) digital elevation model (DEM) data are the basis for the map, which is designed to be used at a broad scale and for informational purposes only. The NED data were derived from the original 1:24,000-scale USGS topographic map bare-earth contours, which were converted into gridded quadrangle-based DEM tiles at a constant post spacing (grid cell size) of either 30 meters (data before the mid-1990s data) or 10 meters (mid-1990s and later data). These individual-quadrangle DEMs were then converted to spherical coordinates (latitude/longitude decimal degrees) and edge-matched to ensure seamlessness. Approximately one-half of the area shown on this map has DEM source data at a 30-meter resolution, with the remaining half consisting of 10-meter contour-derived DEM data or higher-resolution LIDAR data. Areas below sea level typically are surrounded by levees or some other type of flood-control structures. State and county boundary, hydrography, city, and road layers were modified from USGS National Atlas data downloaded in 2003. The NED data were downloaded in 2005.

  18. Measurement of Voluntary Cough Production and Airway Protection in Parkinson Disease

    PubMed Central

    Silverman, Erin P.; Carnaby-Mann, Giselle; Singletary, Floris; Hoffman-Ruddy, Bari; Yeager, James; Sapienza, Christine

    2015-01-01

    Objective To examine relationships between peak expiratory (cough) airflow rate (PEFR) and swallowing symptom severity in participants with Parkinson Disease Design Participants were cued to cough into an analog peak flow meter then swallowed three, 20 mL thin liquid barium boluses. Analyses were directed at detecting potential relationships among disease severity, swallowing symptom severity and PEFR. Participants Sixty eight male and females with PD. Interventions Not applicable Main outcome measures PEFR and swallow symptom severity Results PEFR varied significantly across swallowing severity classifications. Participants with more severe disease displayed a significant, linear decrease in PEFR compared to those participants with earlier stage, less severe disease. Swallowing symptom severity varied significantly across groups when comparing participants with less severe PD to those with more severe PD. Participants with early-stage PD demonstrated little to no swallowing symptoms and had the highest measures of PEFR. In contrast, participants with the most severe swallowing symptoms also displayed the lowest measures of PEFR. Conclusions Relationships existed among PD severity, swallowing symptom severity and PEFR in participants with PD. PEFR may eventually stand as a non-invasive predictor of aspiration risk in those with PD, particularly later-stage disease. Inclusion of PEFRs into existing clinical swallowing assessments may increase the sensitivity and predictive validity of these assessments. PMID:26551228

  19. Electromagnetic Flow Meter Having a Driver Circuit Including a Current Transducer

    NASA Technical Reports Server (NTRS)

    Patel, Sandeep K. (Inventor); Karon, David M. (Inventor); Cushing, Vincent (Inventor)

    2014-01-01

    An electromagnetic flow meter (EMFM) accurately measures both the complete flow rate and the dynamically fluctuating flow rate of a fluid by applying a unipolar DC voltage to excitation coils for a predetermined period of time, measuring the electric potential at a pair of electrodes, determining a complete flow rate and independently measuring the dynamic flow rate during the "on" cycle of the DC excitation, and correcting the measurements for errors resulting from galvanic drift and other effects on the electric potential. The EMFM can also correct for effects from the excitation circuit induced during operation of the EMFM.

  20. Technical trends of large-size photomasks for flat panel displays

    NASA Astrophysics Data System (ADS)

    Yoshida, Koichiro

    2017-06-01

    Currently, flat panel displays (FPDs) are one of the main parts for information technology devices and sets. From 1990's to 2000's, liquid crystal displays (LCDs) and plasma displays had been mainstream FPDs. In the middle of 2000's, demand of plasma displays declined and organic light emitting diodes (OLEDs) newly came into FPD market. And today, major technology of FPDs are LCDs and OLEDs. Especially for mobile devices, the penetration of OLEDs is remarkable. In FPDs panel production, photolithography is the key technology as same as LSI. Photomasks for FPDs are used not only as original master of circuit pattern, but also as a tool to form other functional structures of FPDs. Photomasks for FPDs are called as "Large Size Photomasks(LSPMs)", since the remarkable feature is " Size" which reaches over 1- meter square and over 100kg. In this report, we discuss three LSPMs technical topics with FPDs technical transition and trend. The first topics is upsizing of LSPMs, the second is the challenge for higher resolution patterning, and the last is "Multi-Tone Mask" for "Half -Tone Exposure".

  1. Hydrogen consentration meter utilizing a diffusion tube composed of 2 1/4 C r

    DOEpatents

    Roy, Prodyot; Sandusky, David W.; Hartle, Robert T.

    1979-01-01

    A diffusion tube hydrogen meter for improving the sensitivity and response time for the measurement of hydrogen in liquid sodium. The improved hydrogen meter has a composite membrane composed of pure nickel sleeve fitted, for example, over a 2 1/4 Cr-1 Mo steel or niobium diffusion tube. Since the hydrogen permeation rate through 2 1/4 Cr-1 Mo steels is a factor of four higher than pure nickel, and the permeation rate of hydrogen through niobium is two orders of magnitude greater than the 2 1/4 Cr-1 Mo steel, this results in a decrease in response time and an increase in the sensitivity.

  2. American Recovery and Reinvestment Act of 2009. Interim Report on Customer Acceptance, Retention, and Response to Time-Based Rates from the Consumer Behavior Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappers, Peter; Hans, Liesel; Scheer, Richard

    Time-based rate programs1, enabled by utility investments in advanced metering infrastructure (AMI), are increasingly being considered by utilities as tools to reduce peak demand and enable customers to better manage consumption and costs. There are several customer systems that are relatively new to the marketplace and have the potential for improving the effectiveness of these programs, including in-home displays (IHDs), programmable communicating thermostats (PCTs), and web portals. Policy and decision makers are interested in more information about customer acceptance, retention, and response before moving forward with expanded deployments of AMI-enabled new rates and technologies. Under the Smart Grid Investment Grantmore » Program (SGIG), the U.S. Department of Energy (DOE) partnered with several utilities to conduct consumer behavior studies (CBS). The goals involved applying randomized and controlled experimental designs for estimating customer responses more precisely and credibly to advance understanding of time-based rates and customer systems, and provide new information for improving program designs, implementation strategies, and evaluations. The intent was to produce more robust and credible analysis of impacts, costs, benefits, and lessons learned and assist utility and regulatory decision makers in evaluating investment opportunities involving time-based rates. To help achieve these goals, DOE developed technical guidelines to help the CBS utilities estimate customer acceptance, retention, and response more precisely.« less

  3. State of Florida 1:24,000- and 1:100,000-scale quadrangle index map - Highlighting low-lying areas derived from USGS Digital Elevation Models

    USGS Publications Warehouse

    Kosovich, John J.

    2008-01-01

    In support of U.S. Geological Survey (USGS) disaster preparedness efforts, this map depicts 1:24,000- and 1:100,000-scale quadrangle footprints over a color shaded relief representation of the State of Florida. The first 30 feet of relief above mean sea level are displayed as brightly colored 5-foot elevation bands, which highlight low-elevation areas at a coarse spatial resolution. Standard USGS National Elevation Dataset (NED) 1 arc-second (nominally 30-meter) digital elevation model (DEM) data are the basis for the map, which is designed to be used at a broad scale and for informational purposes only. The NED source data for this map consists of a mixture of 30-meter- and 10-meter-resolution DEMs. The NED data were derived from the original 1:24,000-scale USGS topographic map bare-earth contours, which were converted into gridded quadrangle-based DEM tiles at a constant post spacing (grid cell size) of either 30 meters (data before the mid-1990s) or 10 meters (mid-1990s and later data). These individual-quadrangle DEMs were then converted to spherical coordinates (latitude/longitude decimal degrees) and edge-matched to ensure seamlessness. Figure 1 shows a similar representation for the entire U.S. Gulf Coast, using coarsened 30-meter NED data. Areas below sea level typically are surrounded by levees or some other type of flood-control structures. State and county boundary, hydrography, city, and road layers were modified from USGS National Atlas data downloaded in 2003. Quadrangle names, dated April, 2006, were obtained from the Federal Geographic Names Information System. The NED data were downloaded in 2004.

  4. Payload specialist station study: Volume 2, part 3: Program analysis and planning for phase C/D

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The controls and displays (C&D) required at the Orbiter aft-flight deck (AFD) and the core C&D required at the Payload Specialist Station (PSS) are identified in this document. The AFD C&D Concept consists of a multifunction display system (MFDS) and elements of multiuse mission support equipment (MMSE). The MFDS consists of two CRTs, a display electronics unit (DEU), and a keyboard. The MMSE consists of a manual pointing controller (MPC), five digit numeric displays, 10 character alphanumeric legends, event timers, analog meters, rotary and toggle switches. The MMSE may be hardwired to the experiment, or interface with a data bus at the PSS for signal processing. The MFDS has video capability, with alphanumeric and graphic overlay features, on one CRT and alphanumeric and graphic (tricolor) capability on a second CRT. The DEU will have the capability to communicate, via redundant data buses, with both the spacelab experiment and subsystem computers.

  5. Low Flow Vortex Shedding Flow Meter for Hypergolics/all Media

    NASA Technical Reports Server (NTRS)

    Thinh, Ngo Dinh

    1991-01-01

    A family of vortex shedding flow meters, for measurement of hypergol flows, was designed and fabricated. The test loops to evaluate the flow meters for water flow, as well as Freon -113 flow which simulates the hypergolic fluids, were modified and constructed to utilize a pump system which has an output capacity of 200 gpm. Test runs were conducted on the small 1/2 inch model with Freon 113 and on the larger models with water. Results showed that the linearity between the frequency of the vortices and the flow rate of the fluids was very close to that of the turbine flow meter. It is suggested that the vortex shedding flow meter is a possible replacement for the existing turbine type.

  6. A compact perspiration meter system with capacitive humidity sensor for wearable health-care applications

    NASA Astrophysics Data System (ADS)

    Mitani, Yusuke; Miyaji, Kousuke; Kaneko, Satoshi; Uekura, Takaharu; Momose, Hideya; Johguchi, Koh

    2018-04-01

    This paper presents a compact wearable perspiration meter system using a 180-nm CMOS technology. With custom chip and board design, the proposed perspiration meter, which can measure a qualitative sweating rate, is integrated into 15 × 20 mm2. From the experimental results, the capacitances of the humidity sensors with analog-to-digital converter and band-gap reference circuits can operate accurately without hysteresis. In addition, a demonstration with simulated human skin is carried out to investigate the sensor’s performance under real environments. The proposed perspiration meter can output values equivalent to a conventional meter. As a result, it is verified that the proposed system can be used as a human sweat sensor for wearable application.

  7. Patterns and Controls of Erosion along the Elson Lagoon Coastline, Barrow, Alaska (2003-2016)

    NASA Astrophysics Data System (ADS)

    Tweedie, C. E.; Escarzaga, S. M.; Cody, R. P.; Manley, W. F.; Gaylord, A. G.; Aiken, Q.; Lopez, A. F.; Aguirre, A.; George, C.; Nelson, L.; Brown, J.

    2016-12-01

    With arctic warming and the combined effect of decreased summer sea ice extent, longer fetch for wave propagation, warmer sea surface and ground temperature, and longer periods of open water; the propensity for increased arctic coastal erosion rates and land-ocean sediment inputs to increase has been recognized for some time. In this study, we report on coastal erosion trends along a 11km stretch of coastline adjacent to the Barrow Environmental Observatory (BEO) where the position of the 2-4 meter high coastal bluff has been monitored annually with survey grade differential GPS (dGPS). Modern and historic erosion trends can be viewed through interactive web mapping applications at http://barrowmapped.org/. Rates of aerial and volumetric erosion losses averaged 0.7-2.8 meters and 0.8-3.5 cubic meters per meter of coast per year from 2003-2015 for each of the four coastal sections monitored. These losses equate to losses to the atmosphere and/or inputs to lagoon waters 53-220kgC per meter of coast per year. Such aerial losses are lower than from other areas of the Beaufort Sea coast that lack protective barrier islands, but 25-30% higher than historic decadal-scale change rates estimated for this section of coastline. However, regression analyses indicate no significant change to the rate of erosion during the past 13 years. Historic hotspots of erosion remained modern hotspots of erosion, and increases in modern erosion rates were greatest for sections of coast where historically high rates of erosion have been recorded. Regionally, the Elson Lagoon study area shows some of the highest rates of erosion for the Barrow Peninsula, which are generally 2-3 times mean annual erosion rates recorded for the Chukchi Sea Coastline near Barrow. Regression tree analysis used to isolate the relative importance of different biophysical controls of erosion differ between analyses run for aerial and volumetric losses along the Elson Lagoon Coast. These analyses also highlight key differences in controls between sampling periods with high/low wind-wave activity. In particular, analyses show the important influence of wave energy, land cover type, and landscape geomorphic history on modern coastal erosion dynamics.

  8. An ex ante analysis on the use of activity meters for automated estrus detection: to invest or not to invest?

    PubMed

    Rutten, C J; Steeneveld, W; Inchaisri, C; Hogeveen, H

    2014-11-01

    The technical performance of activity meters for automated detection of estrus in dairy farming has been studied, and such meters are already used in practice. However, information on the economic consequences of using activity meters is lacking. The current study analyzes the economic benefits of a sensor system for detection of estrus and appraises the feasibility of an investment in such a system. A stochastic dynamic simulation model was used to simulate reproductive performance of a dairy herd. The number of cow places in this herd was fixed at 130. The model started with 130 randomly drawn cows (in a Monte Carlo process) and simulated calvings and replacement of these cows in subsequent years. Default herd characteristics were a conception rate of 50%, an 8-wk dry-off period, and an average milk production level of 8,310 kg per cow per 305 d. Model inputs were derived from real farm data and expertise. For the analysis, visual detection by the farmer ("without" situation) was compared with automated detection with activity meters ("with" situation). For visual estrus detection, an estrus detection rate of 50% and a specificity of 100% were assumed. For automated estrus detection, an estrus detection rate of 80% and a specificity of 95% were assumed. The results of the cow simulation model were used to estimate the difference between the annual net cash flows in the "with" and "without" situations (marginal financial effect) and the internal rate of return (IRR) as profitability indicators. The use of activity meters led to improved estrus detection and, therefore, to a decrease in the average calving interval and subsequent increase in annual milk production. For visual estrus detection, the average calving interval was 419 d and average annual milk production was 1,032,278 kg. For activity meters, the average calving interval was 403 d and the average annual milk production was 1,043,398 kg. It was estimated that the initial investment in activity meters would cost €17,728 for a herd of 130 cows, with an additional cost of €90 per year for the replacement of malfunctioning activity meters. Changes in annual net cash flows arising from using an activity meter included extra revenues from increased milk production and number of calves sold, increased costs from more inseminations, calvings, and feed consumption, and reduced costs from fewer culled cows and less labor for estrus detection. These changes in cash flows were caused mainly by changes in the technical results of the simulated dairy herds, which arose from differences in the estrus detection rate and specificity between the "with" and "without" situations. The average marginal financial effect in the "with" and "without" situations was €2,827 for the baseline scenario, with an average IRR of 11%. The IRR is a measure of the return on invested capital. Investment in activity meters was generally profitable. The most influential assumptions on the profitability of this investment were the assumed culling rules and the increase in sensitivity of estrus detection between the "without" and the "with" situation. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. Discharge Measurements in Shallow Urban Streams Using a Hydroacoustic Current Meter

    USGS Publications Warehouse

    Fisher, G.T.; Morlock, S.E.; ,

    2002-01-01

    Hydroacoustic current-meter measurements were evaluated in small urban streams under a range of stages, velocities, and channel-bottom materials. Because flow in urban streams is often shallow, conventional mechanical current-meter measurements are difficult or impossible to make. The rotating-cup Price pygmy meter that is widely used by the U.S. Geological Survey and other agencies should not be used in depths below 0.20 ft and velocities less than 0.30 ft/s. The hydroacoustic device provides measurements at depths as shallow as 0.10 ft and velocities as low as 0.10 ft/s or less. Measurements using the hydroacoustic current meter were compared to conventional discharge measurements. Comparisons with Price-meter measurements were favorable within the range of flows for which the meters are rated. Based on laboratory and field tests, velocity measurements with the hydroacoustic cannot be validated below about 0.07 ft/s. However, the hydroacoustic meter provides valuable information on direction and magnitude of flow even at lower velocities, which otherwise could not be measured with conventional measurements.

  10. Venus: Atmospheric motion and structure from Mariner 10 pictures

    USGS Publications Warehouse

    Murray, B.C.; Belton, M.J.S.; Danielson, G. Edward; Davies, M.E.; Gault, D.; Hapke, B.; O'Leary, B.; Strom, R.G.; Suomi, V.; Trask, N.

    1974-01-01

    The Mariner 10 television cameras imaged the planet Venus in the visible and near ultraviolet for a period of 8 days at resolutions ranging from 100 meters to 130 kilometers. The general pattern of the atmospheric circulation in the upper tropospheric/lower stratospheric region is displayed in the pictures. Atmospheric flow is symmetrical between north and south hemispheres. The equatorial motions are zonal (east-west) at approximately 100 meters per second, consistent with the previously inferred 4-day retrograde rotation. Angular velocity increases with latitude. The subsolar region, and the region downwind from it, show evidence of large-scale convection that persists in spite of the main zonal motion. Dynamical interaction between the zonal motion and the relatively stationary region of convection is evidenced by bowlike waves.

  11. Early views of the martian surface from the Mars Orbiter Camera of Mars Global Surveyor.

    PubMed

    Malin, M C; Carr, M H; Danielson, G E; Davies, M E; Hartmann, W K; Ingersoll, A P; James, P B; Masursky, H; McEwen, A S; Soderblom, L A; Thomas, P; Veverka, J; Caplinger, M A; Ravine, M A; Soulanille, T A; Warren, J L

    1998-03-13

    High-resolution images of the martian surface at scales of a few meters show ubiquitous erosional and depositional eolian landforms. Dunes, sandsheets, and drifts are prevalent and exhibit a range of morphology, composition (inferred from albedo), and age (as seen in occurrences of different dune orientations at the same location). Steep walls of topographic depressions such as canyons, valleys, and impact craters show the martian crust to be stratified at scales of a few tens of meters. The south polar layered terrain and superposed permanent ice cap display diverse surface textures that may reflect the complex interplay of volatile and non-volatile components. Low resolution regional views of the planet provide synoptic observations of polar cap retreat, condensate clouds, and the lifecycle of local and regional dust storms.

  12. [Evaluation of a new electronic handheld meter for measurement of β-hydroxybutyric acid in dairy cows].

    PubMed

    Mahrt, A; Burfeind, O; Voigtsberger, R; Müller, A; Heuwieser, W

    2014-01-01

    Subclinical ketosis (SCK), an important disease in lactating dairy cows, is defined as the presence of elevated concentrations of circulating ketone bodies without the development of clinical signs. Therefore, diagnostic methods are limited to the detection of the concentrations of ketone bodies in different body fluids. The objective of this study was to evaluate a recently developed electronic hand- held meter (NovaVet) for the determination of β-hydroxybutyric acid (BHB) in the blood of dairy cows. A total of 155 lactating dairy cows were included in the trial. Blood samples were taken from each cow and analyzed using the BHB meter. The obtained concentrations were compared to the results determined by a commercial laboratory. The Spearman's rank correlation coefficient was determined between the two methods. A Wilcoxon test was performed and a Bland-Altman plot was generated. Test characteristics (sensitivity, specificity, positive and negative predictive value) for established BHB cut points for the diagnosis of SCK were calculated using receiver operating characteristic (ROC) analysis. The two methods were highly correlated (rs = 0.87; p < 0.05). A difference (median 0.0 mmol/l; interquartile range [IQR] -0.1 to 0.2 mmol/l; p < 0.05) was found between BHB concentrations determined using the BHB meter (median 1.0 mmol/l; IQR 0.7-1.3 mmol/l) and by the laboratory (median 0.9 mmol/l; IQR 0.7-1.1 mmol/l). Using a cut point of 1.2 mmol/l, sensitivity and specificity of the BHB meter were 97% and 82%, respectively. There was a good agreement between BHB concentrations determined using the BHB meter and the laboratory. Furthermore, the BHB meter displayed good test characteristics. The specificity of 82% results in a number of false-positive results. However, this new device can be recommended for the detection of SCK in cows under practical conditions.

  13. Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: implications for establishing correction coefficients on interventional fluoroscopes with KAP meters.

    PubMed

    Wunderle, Kevin A; Rakowski, Joseph T; Dong, Frank F

    2016-05-08

    The first goal of this study was to investigate the accuracy of the displayed reference plane air kerma (Ka,r) or air kerma-area product (Pk,a) over a broad spectrum of X-ray beam qualities on clinically used interventional fluoroscopes incorporating air kerma-area product meters (KAP meters) to measure X-ray output. The second goal was to investigate the accuracy of a correction coefficient (CC) determined at a single beam quality and applied to the measured Ka,r over a broad spectrum of beam qualities. Eleven state-of-the-art interventional fluoroscopes were evaluated, consisting of eight Siemens Artis zee and Artis Q systems and three Philips Allura FD systems. A separate calibrated 60 cc ionization chamber (external chamber) was used to determine the accuracy of the KAP meter over a broad range of clinically used beam qualities. For typical adult beam qualities, applying a single CC deter-mined at 100 kVp with copper (Cu) in the beam resulted in a deviation of < 5% due to beam quality variation. This result indicates that applying a CC determined using The American Association of Physicists in Medicine Task Group 190 protocol or a similar protocol provides very good accuracy as compared to the allowed ± 35% deviation of the KAP meter in this limited beam quality range. For interventional fluoroscopes dedicated to or routinely used to perform pediatric interventions, using a CC established with a low kVp (~ 55-60 kVp) and large amount of Cu filtration (~ 0.6-0.9 mm) may result in greater accuracy as compared to using the 100 kVp values. KAP meter responses indicate that fluoroscope vendors are likely normalizing or otherwise influencing the KAP meter output data. Although this may provide improved accuracy in some instances, there is the potential for large discrete errors to occur, and these errors may be difficult to identify.

  14. Photogrammetric Data Set, 1957-2000, and Bathymetric Measurements for Columbia Glacier, Alaska

    USGS Publications Warehouse

    Krimmel, Robert M.

    2001-01-01

    Major changes in the length, speed, surface altitude, and calving rate of Columbia Glacier, Alaska have been recorded with stereo vertical photography acquired on 119 dates from 1957 to 2000. Photogrammetric analysis of this photographic record has resulted in precise measurement of these changes. From 1982 to 2000 Columbia Glacier retreated 12 kilometers, reduced its thickness by as much as 400 meters, increased its speed from about 5 to 30 meters per day, and increased its calving rate from 3 to 18 million cubic meters per day. All photogrammetric data for Columbia Glacier from 1957 to 2000 are included in this report, as well as supplemental data of ice-dammed lake surface levels, stagnant ice ablation rate, forebay bathymetry, ground control, and camera calibrations. These data are contained in 481 files, all preserved on a CD-ROM included with this report.

  15. Rapid sea level rise in the aftermath of a Neoproterozoic snowball Earth

    NASA Astrophysics Data System (ADS)

    Myrow, P. M.; Lamb, M. P.; Ewing, R. C.

    2018-05-01

    Earth’s most severe climate changes occurred during global-scale “snowball Earth” glaciations, which profoundly altered the planet’s atmosphere, oceans, and biosphere. Extreme rates of glacioeustatic sea level rise are predicted by the snowball Earth hypothesis, but supporting geologic evidence has been lacking. We use paleohydraulic analysis of wave ripples and tidal laminae in the Elatina Formation, Australia—deposited after the Marinoan glaciation ~635 million years ago—to show that water depths of 9 to 16 meters remained nearly constant for ~100 years throughout 27 meters of sediment accumulation. This accumulation rate was too great to have been accommodated by subsidence and instead indicates an extraordinarily rapid rate of sea level rise (0.2 to 0.27 meters per year). Our results substantiate a fundamental prediction of snowball Earth models of rapid deglaciation during the early transition to a supergreenhouse climate.

  16. Quantified Energy Dissipation Rates in the Terrestrial Bow Shock. 2; Waves and Dissipation

    NASA Technical Reports Server (NTRS)

    Wilson, L. B., III; Sibeck, D. G.; Breneman, A. W.; Le Contel, O.; Cully, C.; Turner, D. L.; Angelopoulos, V.; Malaspina, D. M.

    2014-01-01

    We present the first quantified measure of the energy dissipation rates, due to wave-particle interactions, in the transition region of the Earth's collision-less bow shock using data from the Time History of Events and Macro-Scale Interactions during Sub-Storms spacecraft. Our results show that wave-particle interactions can regulate the global structure and dominate the energy dissipation of collision-less shocks. In every bow shock crossing examined, we observed both low-frequency (less than 10 hertz) and high-frequency (approximately or greater than10 hertz) electromagnetic waves throughout the entire transition region and into the magnetosheath. The low-frequency waves were consistent with magnetosonic-whistler waves. The high-frequency waves were combinations of ion-acoustic waves, electron cyclotron drift instability driven waves, electrostatic solitary waves, and whistler mode waves. The high-frequency waves had the following: (1) peak amplitudes exceeding delta B approximately equal to 10 nanoteslas and delta E approximately equal to 300 millivolts per meter, though more typical values were delta B approximately equal to 0.1-1.0 nanoteslas and delta E approximately equal to 10-50 millivolts per meter (2) Poynting fluxes in excess of 2000 microWm(sup -2) (micro-waves per square meter) (typical values were approximately 1-10 microWm(sup -2) (micro-waves per square meter); (3) resistivities greater than 9000 omega meters; and (4) associated energy dissipation rates greater than 10 microWm(sup -3) (micro-waves per cubic meter). The dissipation rates due to wave-particle interactions exceeded rates necessary to explain the increase in entropy across the shock ramps for approximately 90 percent of the wave burst durations. For approximately 22 percent of these times, the wave-particle interactions needed to only be less than or equal to 0.1 percent efficient to balance the nonlinear wave steepening that produced the shock waves. These results show that wave-particle interactions have the capacity to regulate the global structure and dominate the energy dissipation of collision-less shocks.

  17. Deleterious Emission Abatement through Structured Energy Use Pattern: A North Central Nigeria Perspective

    NASA Astrophysics Data System (ADS)

    Ajayi-Banji, Ademola; Omotosho, Olayinka; Amori, Anthony; Alao, Damilola; Igbode, Imoisime; Abimbola, Olufemi

    2016-05-01

    Holistic view of household energy consumption based on greenhouse gas emissions in the North Central cities of Nigeria was examined in this study. Scenarios considered were based on income level of energy users (low and high) and energy metering system (i.e. pre-paid and post-paid energy billing systems). Strong direct nexus was observed between energy use and emissions pattern. Energy utilization by post-paid category had higher weekly average value of 35.09 and 41.70 kWh as against 23.18 and 33.38 kWh for low and high income pre-paid consumers respectively. Energy use and greenhouse gas emissions from both classification followed similar trend. Data obtained and analysed in the study show that global warming and acidification potentials could be reduced by 33.94 and 19.95 % for low and high income category consumers when pre-paid meters are in place. Conclusively, energy system users with pre-paid metering system displayed reasonable level of management decisions that reduce energy wastage and consequently environmental negative impacts.

  18. Tapping to a Slow Tempo in the Presence of Simple and Complex Meters Reveals Experience-Specific Biases for Processing Music

    PubMed Central

    Ullal-Gupta, Sangeeta; Hannon, Erin E.; Snyder, Joel S.

    2014-01-01

    Musical meters vary considerably across cultures, yet relatively little is known about how culture-specific experience influences metrical processing. In Experiment 1, we compared American and Indian listeners' synchronous tapping to slow sequences. Inter-tone intervals contained silence or to-be-ignored rhythms that were designed to induce a simple meter (familiar to Americans and Indians) or a complex meter (familiar only to Indians). A subset of trials contained an abrupt switch from one rhythm to another to assess the disruptive effects of contradicting the initially implied meter. In the unfilled condition, both groups tapped earlier than the target and showed large tap-tone asynchronies (measured in relative phase). When inter-tone intervals were filled with simple-meter rhythms, American listeners tapped later than targets, but their asynchronies were smaller and declined more rapidly. Likewise, asynchronies rose sharply following a switch away from simple-meter but not from complex-meter rhythm. By contrast, Indian listeners performed similarly across all rhythm types, with asynchronies rapidly declining over the course of complex- and simple-meter trials. For these listeners, a switch from either simple or complex meter increased asynchronies. Experiment 2 tested American listeners but doubled the duration of the synchronization phase prior to (and after) the switch. Here, compared with simple meters, complex-meter rhythms elicited larger asynchronies that declined at a slower rate, however, asynchronies increased after the switch for all conditions. Our results provide evidence that ease of meter processing depends to a great extent on the amount of experience with specific meters. PMID:25075514

  19. Ambiguity effects of rhyme and meter.

    PubMed

    Wallot, Sebastian; Menninghaus, Winfried

    2018-04-23

    Previous research has shown that rhyme and meter-although enhancing prosodic processing ease and memorability-also tend to make semantic processing more demanding. Using a set of rhymed and metered proverbs, as well as nonrhymed and nonmetered versions of these proverbs, the present study reveals this hitherto unspecified difficulty of comprehension to be specifically driven by perceived ambiguity. Roman Jakobson was the 1st to propose this hypothesis, in 1960. He suggested that "ambiguity is an intrinsic, inalienable feature" of "parallelistic" diction of which the combination of rhyme and meter is a pronounced example. Our results show that ambiguity indeed explains a substantial portion of the rhyme- and meter-driven difficulty of comprehension. Longer word-reading times differentially reflected ratings for ambiguity and comprehension difficulty. However, the ambiguity effect is not "inalienable." Rather, many rhymed and metered sentences turned out to be low in ambiguity. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  20. Calibrating/testing meters in hot water test bench VM7

    NASA Astrophysics Data System (ADS)

    Kling, E.; Stolt, K.; Lau, P.; Mattiasson, K.

    A Hot Water Test Bench, VM7, has been developed and constructed for the calibration and testing of volume and flowmeters, in a project at the National Volume Measurement Laboratory at the Swedish National Testing and Research Institute. The intended area of use includes use as a reference at audit measurements, e.g. for accredited laboratories, calibration of meters for the industry and for the testing of hot water meters. The objective of the project, which was initiated in 1989, was to design equipment with stable flow and with a minimal temperature drop even at very low flow rates. The principle of the design is a closed system with two pressure tanks at different pressures. The water is led from the high pressure tank through the test object and the volume standard, in the form of master meters or a piston prover alternatively, to the low pressure tank. Calibrations/tests are made comparing the indication of the test object to that of master meters covering the current flow rate. These are, in the same test cycle, calibrated to the piston prover. Alternatively, the test object can be calibrated directly to the piston prover.

  1. A determination of the absolute radiant energy of a Robertson-Berger meter sunburn unit

    NASA Astrophysics Data System (ADS)

    DeLuisi, John J.; Harris, Joyce M.

    Data from a Robertson-Berger (RB) sunburn meter were compared with concurrent measurements obtained with an ultraviolet double monochromator (DM), and the absolute energy of one sunburn unit measured by the RB-meter was determined. It was found that at a solar zenith angle of 30° one sunburn unit (SU) is equivalent to 35 ± 4 mJ cm -2, and at a solar zenith angle of 69°, one SU is equivalent to 20 ± 2 mJ cm -2 (relative to a wavelength of 297 nm), where the rate of change is non-linear. The deviation is due to the different response functions of the RB-meter and the DM system used to simulate the response of human skin to the incident u.v. solar spectrum. The average growth rate of the deviation with increasing solar zenith angle was found to be 1.2% per degree between solar zenith angles 30 and 50° and 2.3% per degree between solar zenith angles 50 and 70°. The deviations of response with solar zenith angle were found to be consistent with reported RB-meter characteristics.

  2. Concept, design and analysis of a large format autostereoscopic display system

    NASA Astrophysics Data System (ADS)

    Knocke, F.; de Jongh, R.; Frömel, M.

    2005-09-01

    Autostereoscopic display devices with large visual field are of importance in a number of applications such as computer aided design projects, technical education, and military command systems. Typical requirements for such systems are, aside from the large visual field, a large viewing zone, a high level of image brightness, and an extended depth of field. Additional appliances such as specialized eyeglasses or head-trackers are disadvantageous for the aforementioned applications. We report on the design and prototyping of an autostereoscopic display system on the basis of projection-type one-step unidirectional holography. The prototype consists of a hologram holder, an illumination unit, and a special direction-selective screen. Reconstruction light is provided by a 2W frequency-doubled Nd:YVO4 laser. The production of stereoscopic hologram stripes on photopolymer is carried out on a special origination setup. The prototype has a screen size of 180cm × 90cm and provides a visual field of 29° when viewed from 3.6 meters. Due to the coherent reconstruction, a depth of field of several meters is achievable. Up to 18 hologram stripes can be arranged on the holder to permit a rapid switch between a series of motifs or views. Both computer generated image sequences and digital camera photos may serve as input frames. However, a comprehensive pre-distortion must be performed in order to account for optical distortion and several other geometrical factors. The corresponding computations are briefly summarized below. The performance of the system is analyzed, aspects of beam-shaping and mechanical design are discussed and photographs of early reconstructions are presented.

  3. An unsupervised classification method for inferring original case locations from low-resolution disease maps.

    PubMed

    Brownstein, John S; Cassa, Christopher A; Kohane, Isaac S; Mandl, Kenneth D

    2006-12-08

    Widespread availability of geographic information systems software has facilitated the use of disease mapping in academia, government and private sector. Maps that display the address of affected patients are often exchanged in public forums, and published in peer-reviewed journal articles. As previously reported, a search of figure legends in five major medical journals found 19 articles from 1994-2004 that identify over 19,000 patient addresses. In this report, a method is presented to evaluate whether patient privacy is being breached in the publication of low-resolution disease maps. To demonstrate the effect, a hypothetical low-resolution map of geocoded patient addresses was created and the accuracy with which patient addresses can be resolved is described. Through georeferencing and unsupervised classification of the original image, the method precisely re-identified 26% (144/550) of the patient addresses from a presentation quality map and 79% (432/550) from a publication quality map. For the presentation quality map, 99.8% of the addresses were within 70 meters (approximately one city block length) of the predicted patient location, 51.6% of addresses were identified within five buildings, 70.7% within ten buildings and 93% within twenty buildings. For the publication quality map, all addresses were within 14 meters and 11 buildings of the predicted patient location. This study demonstrates that lowering the resolution of a map displaying geocoded patient addresses does not sufficiently protect patient addresses from re-identification. Guidelines to protect patient privacy, including those of medical journals, should reflect policies that ensure privacy protection when spatial data are displayed or published.

  4. NaK Plugging Meter Design for the Feasibility Test Loops

    NASA Technical Reports Server (NTRS)

    Pearson, J. Boise; Godfroy, Thomas J.; Reid, Robert S.; Polzin, Kurt A.

    2008-01-01

    The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.

  5. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    PubMed

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and incomplete blood filling of glucose meter strips is often associated with inaccurate reading. These findings underline the importance of appropriate patient education on this aspect of blood glucose self-monitoring. © 2013 Diabetes Technology Society.

  6. Sedimentation Survey of Lago Icacos, Puerto Rico, March 2004

    USGS Publications Warehouse

    Soler-López, Luis R.

    2007-01-01

    The Lago Icacos, a small reservoir built in 1930 and owned by the Puerto Rico Electric Power Authority, is part of the Rio Blanco Hydroelectric Power System. The reservoir is located in Naguabo, within the Caribbean National Forest in eastern Puerto Rico. The original storage capacity of the reservoir was 19,119 cubic meters in 1930. The bathymetric survey conducted by the U.S. Geological Survey in March 2004 indicates a storage capacity of 7,435 cubic meters or 39 percent of the original storage capacity, and a maximum depth of 5.3 meters. The reservoir has been dredged several times to restore lost storage capacity caused by high sediment loads and the frequent landslides that occur upstream from the dam, which have partially or completely filled the Lago Icacos. Because sediment removal activities have not been documented, sedimentation rates could not be determined using storage volume comparisons. A reservoir sedimentation rate was calculated using the daily sediment load data gathered at the U.S. Geological Survey Rio Icacos streamflow station upstream of the reservoir, the estimated Lago Icacos sediment trapping efficiency, and the estimated sediment yield of the Lago Icacos basin extrapolated from the Rio Icacos sediment load data. Using these properties, the Lago Icacos sedimentation rate was estimated as 71 cubic meters per year, equivalent to about 1 percent of the original storage capacity per year. The Lago Icacos 7.47-square-kilometer drainage area sediment yield was estimated as 7,126 tonnes per year or about 954 tonnes per square kilometer per year. Based on the current estimated sedimentation rate of 71 cubic meters per year, Lago Icacos has a useful life of about 105 years or to year 2109.

  7. Measuring peak expiratory flow in general practice: comparison of mini Wright peak flow meter and turbine spirometer.

    PubMed Central

    Jones, K P; Mullee, M A

    1990-01-01

    OBJECTIVE--To compare measurements of the peak expiratory flow rate taken by the mini Wright peak flow meter and the turbine spirometer. DESIGN--Pragmatic study with randomised order of use of recording instruments. Phase 1 compared a peak expiratory flow type expiration recorded by the mini Wright peak flow meter with an expiration to forced vital capacity recorded by the turbine spirometer. Phase 2 compared peak expiratory flow type expirations recorded by both meters. Reproducibility was assessed separately. SETTING--Routine surgeries at Aldermoor Health Centre, Southampton. SUBJECTS--212 Patients aged 4 to 78 presenting with asthma or obstructive airways disease. Each patient contributed only once to each phase (105 in phase 1, 107 in phase 2), but some entered both phases on separate occasions. Reproducibility was tested on a further 31 patients. MAIN OUTCOME MEASURE--95% Limits of agreement between measurements on the two meters. RESULTS--208 (98%) Of the readings taken by the mini Wright meter were higher than the corresponding readings taken by the turbine spirometer, but the 95% limits of agreement (mean difference (2 SD] were wide (1 to 173 l/min). Differences due to errors in reproducibility were not sufficient to predict this level of disagreement. Analysis by age, sex, order of use, and the type of expiration did not detect any significant differences. CONCLUSIONS--The two methods of measuring peak expiratory flow rate were not comparable. The mini Wright meter is likely to remain the preferred instrument in general practice. PMID:2142611

  8. Using RADFET for the real-time measurement of gamma radiation dose rate

    NASA Astrophysics Data System (ADS)

    Andjelković, Marko S.; Ristić, Goran S.; Jakšić, Aleksandar B.

    2015-02-01

    RADFETs (RADiation sensitive Field Effect Transistors) are integrating ionizing radiation dosimeters operating on the principle of conversion of radiation-induced threshold voltage shift into absorbed dose. However, one of the major drawbacks of RADFETs is the inability to provide the information on the dose rate in real-time using the conventional absorbed dose measurement technique. The real-time monitoring of dose rate and absorbed dose can be achieved with the current mode dosimeters such as PN and PIN diodes/photodiodes, but these dosimeters have some limitations as absorbed dose meters and hence they are often not a suitable replacement for RADFETs. In that sense, this paper investigates the possibility of using the RADFET as a real-time dose rate meter so that it could be applied for simultaneous online measurement of the dose rate and absorbed dose. A RADFET sample, manufactured by Tyndall National Institute, Cork, Ireland, was tested as a dose rate meter under gamma irradiation from a Co-60 source. The RADFET was configured as a PN junction, such that the drain, gate and source terminals were grounded, while the radiation-induced current was measured at the bulk terminal, whereby the bulk was successively biased with 0 , 10 , 20  and 30 V. In zero-bias mode the radiation-induced current was unstable, but in the biased mode the current response was stable for the investigated dose rates from 0.65  to 32.1 Gy h-1 and up to the total absorbed dose of 25 Gy. The current increased with the dose rate in accordance with the power law, whereas the sensitivity of the current read-out was linear with respect to the applied bias voltage. Comparison with previously analyzed PIN photodiodes has shown that the investigated RADFET is competitive with PIN photodiodes as a gamma radiation dose rate meter and therefore has the potential to be employed for the real-time monitoring of the dose rate and absorbed dose.

  9. 40 CFR Table 2 to Subpart D of... - TRE Parameters for NSPS Referencing Subpartsa

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...? Net heating value(MJ/scm)b Vent stream flow rate (scm/min)c Values of terms for TRE equation: TRE=A... § 65.64(h). b MJ/scm = mega Joules per standard cubic meter. c scm/min = standard cubic meters per...

  10. 40 CFR Table 2 to Subpart D of... - TRE Parameters for NSPS Referencing Subpartsa

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...? Net heating value(MJ/scm)b Vent stream flow rate (scm/min)c Values of terms for TRE equation: TRE=A... § 65.64(h). b MJ/scm = mega Joules per standard cubic meter. c scm/min = standard cubic meters per...

  11. Characterizing Accuracy and Precision of Glucose Sensors and Meters

    PubMed Central

    2014-01-01

    There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute relative deviation (ARD) and /or %CV versus glucose level to better characterize measurement errors at any glucose level. We examine the relationship between glucose measured by test and comparator methods using linear regression. We examine bias by plotting deviation = (test – comparator method) versus glucose level. We compute the deviation, absolute deviation (AD), ARD, and standard deviation (SD) for each data pair. We utilize curve smoothing procedures to minimize the effects of random sampling variability to facilitate identification and display of the underlying relationships between ARD or %CV and glucose level. AD, ARD, SD, and %CV display smooth continuous relationships versus glucose level. Estimates of MARD and %CV are subject to relatively large errors in the hypoglycemic range due in part to a markedly nonlinear relationship with glucose level and in part to the limited number of observations in the hypoglycemic range. The curvilinear relationships of ARD and %CV versus glucose level are helpful when characterizing and comparing the precision and accuracy of glucose sensors and meters. PMID:25037194

  12. Sea Salt Aerosol, Atmospheric Radon and Meteorological Observations in the Western South Atlantic Ocean (February 1981).

    DTIC Science & Technology

    1983-09-28

    approximately isokinetic sampling conditions. The blower motor for the hi-vol was separated from the filter holder unit by a one- meter length of flexible...bridge bulkhead about 15 m above sea level and within 3 meters of the ARCAS inlet. The flow rate through the 20 cm x 25 cm glass fiber filters was...materials, atmospheric pressure, soil moisture and vegetative cover (Larson and Bressan, 1980). Radon concentrations measured a few meters above

  13. Measurement of the ambient gamma dose equivalent and kerma from the small 252Cf source at 1 meter and the small 60Co source at 2 meters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carl, W. F.

    NASA Langley Research Center requested a measurement and determination of the ambient gamma dose equivalent rate and kerma at 100 cm from the 252Cf source and determination of the ambient gamma dose equivalent rate and kerma at 200 cm from the 60Co source for the Radiation Budget Instrument Experiment (Rad-X). An Exradin A6 ion chamber with Shonka air-equivalent plastic walls in combination with a Supermax electrometer were used to measure the exposure rate and free-in-air kerma rate of the two sources at the requested distances. The measured gamma exposure, kerma, and dose equivalent rates are tabulated.

  14. North Carolina | Midmarket Solar Policies in the United States | Solar

    Science.gov Websites

    impose standby charges consistent with approved standby rates applicable to other customer-owned utilities without customer compensation. RECs: Utilities owns renewable energy certificates (RECs), unless customer chooses to net meter under a time of use tariff with demand charges. Meter aggregation: Not

  15. Environmental Assessment for Selected Regions in the Mediterranean Sea

    DTIC Science & Technology

    1992-01-01

    derived from gravity and turbidity flows and include ash layers interbedded with hemipelagic mud. Sedimen- tation rates in these regions are on the order of...CURRENT METERS, ALBORAN I (PISTEK 1984)0& CURRENT METERS, ALBORAN III (PISTEK 1987) A DRIFTING CURRENT METERIS , ALBORAN 11 (PISTEK 1987) 0: CURRENT

  16. Simulation of ground-water discharge to Biscayne Bay, southeastern Florida

    USGS Publications Warehouse

    Langevin, Christian David

    2001-01-01

    As part of the Place-Based Studies Program, the U.S. Geological Survey initiated a project in 1996, in cooperation with the U.S. Army Corps of Engineers, to quantify the rates and patterns of submarine ground-water discharge to Biscayne Bay. Project objectives were achieved through field investigations at three sites (Coconut Grove, Deering Estate, and Mowry Canal) along the coastline of Biscayne Bay and through the development and calibration of variable-density, ground-water flow models. Two-dimensional, vertical cross-sectional models were developed for steady-state conditions for the Coconut Grove and Deering Estate transects to quantify local-scale ground-water discharge patterns to Biscayne Bay. A larger regional-scale model was developed in three dimensions to simulate submarine ground-water discharge to the entire bay. The SEAWAT code, which is a combined version of MODFLOW and MT3D, was used to simulate the complex variable-density flow patterns. Field data suggest that ground-water discharge to Biscayne Bay relative to the shoreline is restricted to within 300 meters at Coconut Grove, 600 to 1,000 meters at Deering Estate, and 100 meters at Mowry Canal. The vertical cross-sectional models, which were calibrated to the field data using the assumption of steady state, tend to focus ground-water discharge to within 50 to 200 meters of the shoreline. With homogeneous distributions for aquifer parameters and a constant-concentration boundary for Biscayne Bay, the numerical models could not reproduce the lower ground-water salinities observed beneath the bay, which suggests that further research may be necessary to improve the accuracy of the numerical simulations. Results from the cross-sectional models, which were able to simulate the approximate position of the saltwater interface, suggest that longitudinal dispersivity ranges between 1 and 10 meters, and transverse dispersivity ranges from 0.1 to 1 meter for the Biscayne aquifer. The three-dimensional, regional-scale model was calibrated to ground-water heads, canal baseflow, and the general position of the saltwater interface for nearly a 10-year period from 1989 to 1998. The mean absolute error between observed and simulated head values is 0.15 meter. The mean absolute error between observed and simulated baseflow is 3 x 105 cubic meters per day. The position of the simulated saltwater interface generally matches the position observed in the field, except for areas north of the Miami Canal where the simulated saltwater interface is located about 5 kilometers inland of the observed saltwater interface. Results from the regional-scale model suggest that the average rate of fresh ground-water discharge to Biscayne Bay for the 10-year period (1989-98) is about 2 x 105 cubic meters per day for 100 kilometers of coastline. This simulated discharge rate is about 6 percent of the measured surface-water discharge to Biscayne Bay for the same period. The model also suggests that nearly 100 percent of the fresh ground-water discharge is to the northern half of Biscayne Bay, north of the Cutler Drain Canal. South of the Cutler Drain Canal, coastal lowlands prevent the water table from rising high enough to drive measurable quantities of ground water to Biscayne Bay. Annual variations in sea-level elevation, which can be as large as 0.3 meter, have a substantial effect on rates of ground-water discharge. During 1989-98, simulated rates of ground-water discharge to Biscayne Bay generally are highest when sea level is relatively low.

  17. Shore erosion as a sediment source to the tidal Potomac River, Maryland and Virginia

    USGS Publications Warehouse

    Miller, Andrew J.

    1987-01-01

    The shoreline of the tidal Potomac River attained its present form as a result of the Holocene episode of sea-level rise; the drowned margins of the system are modified by wave activity in the shore zone and by slope processes on banks steepened by basal-wave erosion. Shore erosion leaves residual sand and gravel in shallow water and transports silt and clay offshore to form a measurable component of the suspended-sediment load of the tidal Potomac River. Erosion rates were measured by comparing digitized historical shoreline maps and modern maps, and by comparing stereopairs of aerial photographs taken at different points in time, with the aid of an interactive computer-graphics system and a digitizing stereoplotter. Cartographic comparisons encompassed 90 percent of the study reach and spanned periods of 38 to 109 years, with most measurements spanning at least 84 years. Photogrammetric comparisons encompassed 49 percent of the study reach and spanned 16 to 40 years. Field monitoring of erosion rates and processes at two sites, Swan Point Neck, Maryland, and Mason Neck, Virginia, spanned periods of 10 to 18 months. Estimated average recession rates of shoreline in the estuary, based on cartographic and photogrammetric measurements, were 0.42 to 0.52 meter per annum (Virginia shore) and 0.31 to 0.41 meter per annum (Maryland shore). Average recession rates of shoreline in the tidal river and transition zone were close to 0.15 meter per annum. Estimated average volume-erosion rates along the estuary were 1.20 to 1.87 cubic meters per meter of shoreline per annum (Virginia shore) and 0.56 to 0.73 cubic meter per meter of shoreline per annum (Maryland shore); estimated average volume-erosion rates along the shores of the tidal river and transition zone were 0.55 to 0.74 cubic meter per meter of shoreline per annum. Estimated total sediment contributed to the tidal Potomac River by shore erosion was 0.375 x 10 6 to 0.565 x 10 6 metric tons per annum; of this, the estimated amount of silt and clay ranged from 0.153x10 6 to 0.226x10 6 metric tons per annum. Between 49 and 60 percent of the sediment was derived from the Virginia shore of the estuary; 14 to 18 percent was derived from the Maryland shore of the estuary; and 23 to 36 percent was derived from the shores of the tidal river and transition zone. The adjusted modern estimate of sediment eroded from the shoreline of the estuary is about 55 percent of the historical estimate. Sediment eroded from the shoreline accounted for about 6 to 9 percent of the estimated total suspended load for the tidal Potomac River during water years 1979 through 1981 and for about 11 to 18 percent of the suspended load delivered to the estuary during the same period. Annual suspended-sediment loads derived from upland source areas fluctuated by about an order of magnitude during the 3 years of record (1979-81); shore erosion may have been a more important component of the sediment budget during periods of low flow than during periods of higher discharges. Prior to massive land clearance during the historical period of intensive agriculture in the 18th and 19th centuries, annual sediment loads from upland sources probably were smaller than they are at present; under these circumstances shore erosion would have been an important component of the sediment budget. At current rates of sediment supply, relative sea-level rise, and shoreline recession, the landward parts of the tidal Potomac River are rapidly being filled by sediment. If these rates were to remain constant over time, and no sediment were to escape into Chesapeake Bay, the tidal river and transition zone would be filled within 600 years, and the total system would be filled in less than 4,000 years. Given a slower rate of sediment supply, comparable to the measured rate during the low-flow 1981 water year, the volume of the tidal Potomac River might remain relatively stable or even increase over time. Changes in rates

  18. Assessment of ambient gamma dose rate around a prospective uranium mining area of South India - A comparative study of dose by direct methods and soil radioactivity measurements

    NASA Astrophysics Data System (ADS)

    Karunakara, N.; Yashodhara, I.; Sudeep Kumara, K.; Tripathi, R. M.; Menon, S. N.; Kadam, S.; Chougaonkar, M. P.

    Indoor and outdoor gamma dose rates were evaluated around a prospective uranium mining region - Gogi, South India through (i) direct measurements using a GM based gamma dose survey meter, (ii) integrated measurement days using CaSO4:Dy based thermo luminescent dosimeters (TLDs), and (iii) analyses of 273 soil samples for 226Ra, 232Th, and 40K activity concentration using HPGe gamma spectrometry. The geometric mean values of indoor and outdoor gamma dose rates were 104 nGy h-1 and 97 nGy h-1, respectively with an indoor to outdoor dose ratio of 1.09. The gamma dose rates and activity concentrations of 226Ra, 232Th, and 40K varied significantly within a small area due to the highly localized mineralization of the elements. Correlation study showed that the dose estimated from the soil radioactivity is better correlated with that measured directly using the portable survey meter, when compared to that obtained from TLDs. This study showed that in a region having localized mineralization in situ measurements using dose survey meter provide better representative values of gamma dose rates.

  19. LiDAR-Derived Flood-Inundation Maps for Real-Time Flood-Mapping Applications, Tar River Basin, North Carolina

    USGS Publications Warehouse

    Bales, Jerad D.; Wagner, Chad R.; Tighe, Kirsten C.; Terziotti, Silvia

    2007-01-01

    Flood-inundation maps were created for selected streamgage sites in the North Carolina Tar River basin. Light detection and ranging (LiDAR) data with a vertical accuracy of about 20 centimeters, provided by the Floodplain Mapping Information System of the North Carolina Floodplain Mapping Program, were processed to produce topographic data for the inundation maps. Bare-earth mass point LiDAR data were reprocessed into a digital elevation model with regularly spaced 1.5-meter by 1.5-meter cells. A tool was developed as part of this project to connect flow paths, or streams, that were inappropriately disconnected in the digital elevation model by such features as a bridge or road crossing. The Hydraulic Engineering Center-River Analysis System (HEC-RAS) model, developed by the U.S. Army Corps of Engineers, was used for hydraulic modeling at each of the study sites. Eleven individual hydraulic models were developed for the Tar River basin sites. Seven models were developed for reaches with a single gage, and four models were developed for reaches of the Tar River main stem that receive flow from major gaged tributaries, or reaches in which multiple gages were near one another. Combined, the Tar River hydraulic models included 272 kilometers of streams in the basin, including about 162 kilometers on the Tar River main stem. The hydraulic models were calibrated to the most current stage-discharge relations at 11 long-term streamgages where rating curves were available. Medium- to high-flow discharge measurements were made at some of the sites without rating curves, and high-water marks from Hurricanes Fran and Floyd were available for high-stage calibration. Simulated rating curves matched measured curves over the full range of flows. Differences between measured and simulated water levels for a specified flow were no more than 0.44 meter and typically were less. The calibrated models were used to generate a set of water-surface profiles for each of the 11 modeled reaches at 0.305-meter increments for water levels ranging from bankfull to approximately the highest recorded water level at the downstream-most gage in each modeled reach. Inundated areas were identified by subtracting the water-surface elevation in each 1.5-meter by 1.5-meter grid cell from the land-surface elevation in the cell through an automated routine that was developed to identify all inundated cells hydraulically connected to the cell at the downstream-most gage in the model domain. Inundation maps showing transportation networks and orthoimagery were prepared for display on the Internet. These maps also are linked to the U.S. Geological Survey North Carolina Water Science Center real-time streamflow website. Hence, a user can determine the near real-time stage and water-surface elevation at a U.S. Geological Survey streamgage site in the Tar River basin and link directly to the flood-inundation maps for a depiction of the estimated inundated area at the current water level. Although the flood-inundation maps represent distinct boundaries of inundated areas, some uncertainties are associated with these maps. These are uncertainties in the topographic data for the hydraulic model computational grid and inundation maps, effective friction values (Manning's n), model-validation data, and forecast hydrographs, if used. The Tar River flood-inundation maps were developed by using a steady-flow hydraulic model. This assumption clearly has less of an effect on inundation maps produced for low flows than for high flows when it typically takes more time to inundate areas. A flood in which water levels peak and fall slowly most likely will result in more inundation than a similar flood in which water levels peak and fall quickly. Limitations associated with the steady-flow assumption for hydraulic modeling vary from site to site. The one-dimensional modeling approach used in this study resulted in good agreement between measurements and simulations. T

  20. Sedimentation Survey of Lago Toa Vaca, Puerto Rico, June-July 2002

    USGS Publications Warehouse

    Soler-López, Luis R.

    2004-01-01

    The Lago Toa Vaca dam is located in the municipality of Villalba in southern Puerto Rico, and is owned and operated by the Puerto Rico Aqueduct and Sewer Authority. Construction was completed in 1972 as the first phase of a multi-purpose project that contemplated four possible diversions from other basins to mitigate the rapid storage capacity loss of Lago Guayabal, located immediately downstream of the Toa Vaca dam. The latter phases of the intra-basin diversions were cancelled, and currently, the reservoir receives runoff from only 56.8 square kilometers of its drainage area. Lago Toa Vaca reservoir when constructed was to be used for irrigation of croplands in the southern coastal plain. The reservoir had an original storage capacity of 68.94 million cubic meters. Sedimentation has reduced the storage capacity by only 7 percent between 1972 and 2002 to 64.08 million cubic meters. This represents a long-term sedimentation rate of about 162,000 cubic meters per year. Based on the 2002 sedimentation survey, Lago Toa Vaca has a sediment trapping efficiency of about 98 percent and a drainage area-normalized sedimentation rate of about 3,086 cubic meters per square kilometer per year between 1972 and 2002. At the current long-term sedimentation rate the reservoir would lose its storage capacity by the year 2400.

  1. Component-Based Visualization System

    NASA Technical Reports Server (NTRS)

    Delgado, Francisco

    2005-01-01

    A software system has been developed that gives engineers and operations personnel with no "formal" programming expertise, but who are familiar with the Microsoft Windows operating system, the ability to create visualization displays to monitor the health and performance of aircraft/spacecraft. This software system is currently supporting the X38 V201 spacecraft component/system testing and is intended to give users the ability to create, test, deploy, and certify their subsystem displays in a fraction of the time that it would take to do so using previous software and programming methods. Within the visualization system there are three major components: the developer, the deployer, and the widget set. The developer is a blank canvas with widget menu items that give users the ability to easily create displays. The deployer is an application that allows for the deployment of the displays created using the developer application. The deployer has additional functionality that the developer does not have, such as printing of displays, screen captures to files, windowing of displays, and also serves as the interface into the documentation archive and help system. The third major component is the widget set. The widgets are the visual representation of the items that will make up the display (i.e., meters, dials, buttons, numerical indicators, string indicators, and the like). This software was developed using Visual C++ and uses COTS (commercial off-the-shelf) software where possible.

  2. Energy transfer model and its applications of ultrasonic gas flow-meter under static and dynamic flow rates

    NASA Astrophysics Data System (ADS)

    Fang, Min; Xu, Ke-Jun; Zhu, Wen-Jiao; Shen, Zi-Wen

    2016-01-01

    Most of the ultrasonic gas flow-meters measure the gas flow rate by calculating the ultrasonic transmission time difference between the downstream and upstream. Ultrasonic energy attenuation occurs in the processes of the ultrasonic generation, conversion, transmission, and reception. Additionally, at the same time, the gas flow will also affect the ultrasonic propagation during the measurement, which results in the ultrasonic energy attenuation and the offset of ultrasonic propagation path. Thus, the ultrasonic energy received by the transducer is weaker. When the gas flow rate increases, this effect becomes more apparent. It leads to the measurement accuracy reduced, and the measurement range narrowed. An energy transfer model, where the ultrasonic gas flow-meter under without/with the gas flow, is established by adopting the statistical analysis and curve fitting based on a large amount of experimental data. The static sub model without the gas flow expresses the energy conversion efficiency of ultrasonic gas transducers, and the dynamic sub model with the gas flow reflects the energy attenuation pattern following the flow rate variations. The mathematical model can be used to determine the minimum energy of the excitation signal for meeting the requirement of specific measurement range, and predict the maximum measurable flow rate in the case of fixed energy of excitation signal. Based on the above studies, a method to enhance the excitation signal energy is proposed under the output power of the transmitting circuit being a finite value so as to extend the measurement rage of ultrasonic gas flow-meter.

  3. Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method

    NASA Astrophysics Data System (ADS)

    Arai, Kenta; Yoshida, Hajime

    2014-10-01

    Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.

  4. Field Evaluation of Seepage Meters in the Coastal Marine Environment

    NASA Astrophysics Data System (ADS)

    Cable, J. E.; Burnett, W. C.; Chanton, J. P.; Corbett, D. R.; Cable, P. H.

    1997-09-01

    The response of seepage meters was evaluated in a nearshore marine environment where water motion effects are more pronounced than in lake settings, where these meters have been used traditionally. Temporal and spatial variations of seepage, as well as potential artifacts, were evaluated using empty and 1000-ml pre-filled bag measurements. Time-series measurements confirmed earlier observations that anomalously high fluxes occur during the early stages (≤10 min) of collection. As deployment times increased (30-60 min), measured flow rates stabilized at a level thought to represent the actual seepage flux. Pre-filling the plastic measurement bags effectively alleviated this anomalous, short-term influx. Reliable seepage measurements required deployment times sufficient to allow a net volume of at least 150 ml into the collection bag. Control experiments, designed by placing seepage meters inside sand-filled plastic swimming pools, served as indicators of external effects on these measurements, i.e. they served as seepage meter blanks. When winds were under 15 knots, little evidence was found that water motion caused artifacts in the seepage measurements. Tidal cycle influences on seepage rates were negligible in the present study area, but long-term temporal variations (weeks to months) proved substantial. Observed long-term changes in groundwater flux into the Gulf of Mexico correlated with water table elevation at a nearby monitoring well.

  5. Sedimentation survey of Lago Loco, Puerto Rico, March 2000

    USGS Publications Warehouse

    Soler-López, Luis R.

    2002-01-01

    Lago Loco, a small reservoir property of the Puerto Rico Electric Power Authority and part of the Southwestern Puerto Rico Project, has lost 64 percent of its original storage capacity. In 1951, the original storage capacity was about 2.40 million cubic meters, decreasing to 1.43 million cubic meters in 1986 and to 0.87 million cubic meters in March 2000. The storage loss or longterm sedimentation rate increased from 27,714 cubic meters per year from the period of 1951 to 1986 to 31,224 cubic meters per year for the period of 1951 to 2000. This represents a capacity loss of about 1.1 percent per year for the period of 1951 to 1986 and 1.3 percent per year for 1951 to 2000. The trapping efficiency of the reservoir was about 92 percent in 1951, decreasing to about 87 percent in 1986, and to about 80 percent in March 2000. The sediment yield of the net sediment- contributing drainage area increased from 1,504 megagrams per square kilometer per year between 1951 and 1986 to 1,774 megagrams per square kilometer per year between 1951 and 2000, or about 18 percent. At the current sedimentation rate of the reservoir, the life expectancy of Lago Loco is about 28 more years or until the year 2028.

  6. Effect of heavy back squats on repeated sprint performance in trained men.

    PubMed

    Duncan, M J; Thurgood, G; Oxford, S W

    2014-04-01

    This study examined the impact of post activation potentiation on repeated sprint performance in trained Rugby Union players. Ten, male, professional Rugby Union players (mean age=25.2±5.02 years) performed 7, 30-meter sprints, separated by 25 seconds, 4 minutes following back squats (90% 1 repetition maximum) or a control condition performed in a counterbalanced order. Significant condition X sprint interactions for 10-meter (P=0.02) and 30-meter (P=0.05) indicated that times were significantly faster in the PAP condition for sprints 5, 6 and 7 across both distances. Fatigue rate was also significantly lower in the PAP condition for 10-meter (P=0.023) and 30-meter (P=0.006) sprint running speed. This study evidences that a heavy resistance exercise stimulus administered four minutes prior to repeated sprints can offset the decline in sprint performance seen during subsequent maximal sprinting over 10 and 30-meters in Rugby Union players.

  7. Remote semi-continuous flow rate logging seepage meter

    NASA Technical Reports Server (NTRS)

    Reay, William G.; Walthall, Harry G.

    1991-01-01

    The movement of groundwater and its associated solutes from upland regions was implicated in the degradation of receiving surface water bodies. Current efforts to directly measure this influx of water incorporate manually operated seepage meters which are hindered by severe limitations. A prototype seepage meter was developed by NASA Langley Research Center and Virginia Polytechnic Institute and State University that will allow for the semi-continuous collection and data logging of seepage flux across the sediment water interface. The meter is designed to operate at depths to 40 meters, and alleviate or minimize all disadvantages associated with traditional methods while remaining cost effective. The unit was designed to operate independently for time periods on the order of weeks with adjustable sample sequences depending upon hydrologic conditions. When used in conjunction with commercially available pressure transducers, this seepage meter allows for correlations to be made between groundwater discharge and tidal/sea state conditions in coastal areas. Field data from the Chesapeake Bay and Florida Bay systems are presented.

  8. Assessment of neutron dosemeters around standard sources and nuclear fissile objects.

    PubMed

    Raimondi, N; Tournier, B; Groetz, J E; Piot, J; Riebler, E; Crovisier, P; Chambaudet, A; Cabanné, N

    2002-01-01

    In order to evaluate the neutron doses around nuclear fissile objects, a comparative study has been made on several neutron dosemeters: bubble dosemeters, etched-track detectors (CR-39) and 3He-filled proportional counters used as dose-rate meters. The measurements were made on the ambient and the personal dose equivalents H*(10) and Hp(10). Results showed that several bubble dosemeters should have been used due to a low reproducibility in the measurements. A strong correlation with the neutron energy was also found, with about a 30% underestimation of Hp(10) for neutrons from the PuBe source, and about a 9% overestimation for neutrons from the 252Cf source. Measurements of the nuclear fissile objects were made using the CR-39 and the dose-rate meters. The CR-39 led to an underestimation of 30% with respect to the neutron dose-rate meter measurements. In addition, the MCNP calculation code was used in the different configurations.

  9. Energy Harvesting from Fluid Flow in Water Pipelines for Smart Metering Applications

    NASA Astrophysics Data System (ADS)

    Hoffmann, D.; Willmann, A.; Göpfert, R.; Becker, P.; Folkmer, B.; Manoli, Y.

    2013-12-01

    In this paper a rotational, radial-flux energy harvester incorporating a three-phase generation principle is presented for converting energy from water flow in domestic water pipelines. The energy harvester together with a power management circuit and energy storage is used to power a smart metering system installed underground making it independent from external power supplies or depleting batteries. The design of the radial-flux energy harvester is adapted to the housing of a conventional mechanical water flow meter enabling the use of standard components such as housing and impeller. The energy harvester is able to generate up to 720 mW when using a flow rate of 20 l/min (fully opened water tab). A minimum flow rate of 3 l/min is required to get the harvester started. In this case a power output of 2 mW is achievable. By further design optimization of the mechanical structure including the impeller and magnetic circuit the threshold flow rate can be further reduced.

  10. A direct reading exposure monitor for radiation processing

    NASA Astrophysics Data System (ADS)

    Kantz, A. D.; Humpherys, K. C.

    Various plastic films have been utilized to measure radiation fields. In general such films are rugged, easily handled, small enough to cause neligible perturbation on the radiation fields, and relatively inexpensive. The radiachromic materials have been shown to have advantages over other plastic fabrications in stability, reproducibility, equivalent response to electron and gamma ray processing fields, dose rate independence, and ready availability of calibration standards. Using a nylon matrix radiachromic detector, a system of direct read-out of absorbed dose has been developed to facilitate monitoring in the megarad region. When an exposed detector is inserted into the reader, the optical transmission signal is processed through an analog to digital converter. The digitized signal addresses a memory bank where the standard response curve is stored. The corresponding absorbed dose is displayed on a digital panel meter. The variation of relative sensitivity of detectors, the background of unirradiated detectors, environmental parameters, and the capacity of the memory bank are contributing factors to the total precision of the read-out system.

  11. A Common Fluence Threshold for First Positive and Second Positive Phototropism in Arabidopsis thaliana1

    PubMed Central

    Janoudi, Abdul; Poff, Kenneth L.

    1990-01-01

    The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 × 10−5 to 6.5 × 10−3 micromoles per square meter per second. The threshold values in the fluence rateresponse curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system. PMID:11537470

  12. Estimating pumping time and ground-water withdrawals using energy- consumption data

    USGS Publications Warehouse

    Hurr, R.T.; Litke, D.W.

    1989-01-01

    Evaluation of the hydrology of an aquifer requires knowledge about the volume of groundwater in storage and also about the volume of groundwater withdrawals. Totalizer flow meters may be installed at pumping plants to measure withdrawals; however, it generally is impractical to equip all pumping plants in an area with meters. A viable alternative is the use of rate-time methods. Rate-time methods may be used at individual pumping plants to decrease the data collection necessary for determining withdrawals. At sites where pumping-time measurement devices are not installed, pumping time may be determined on the basis of energy consumption and power demand. At pumping plants where energy consumption is metered, data acquired by reading of meters is used to estimate pumping time. Care needs to be taken to read these meters correctly. At pumping plants powered by electricity, the calculations need to be modified if transformers are present. At pumping plants powered by natural gas, the effects of the pressure-correction factor need to be included in the calculations. At pumping plants powered by gasoline, diesel oil, or liquid petroleum gas, the geometry of storage tanks needs to be analyzed as part of the calculations. The relation between power demand and pumping rate at a pumping plant can be described through the use of the power-consumption coefficient. Where equipment and hydrologic conditions are stable, this coefficient can be applied to total energy consumption at a site to estimate total groundwater withdrawals. Random sampling of power consumption coefficients can be used to estimate area-wide groundwater withdrawal. (USGS)

  13. Compliance with Tobacco Promotion and Sale Laws in School Neighbourhoods in India

    PubMed Central

    Balappanavar, Aswini Y; Mohanty, Vikrant; Hussain, Abrar

    2017-01-01

    Objective: Regulation of sale of tobacco has given sufficient attention in India and little information exists about the impact of bans near schools. Our study aim was to check the levels of tobacco promotion, advertising and sales in school neighborhoods’ of Central Delhi. Methods: Using multistage random sampling 15 schools were selected in Central Delhi. Areas 100 meters around each were mapped using a map tool and screened using a self designed questionnaire consisting of 26 questions, both closed and open ended, to determine the details of outlets, sales of tobacco and tobacco products, advertising, promotions, school roles, and children seeking tobacco. The data were subjected to statistical analysis. Results: The response rate was 65%. Outlet licenses were present in only 6 (3.47%). The point sale of tobacco was most frequently in tea stalls and a total of 173 (41.2%) outlets had some form of tobacco sale. The brands of smokeless tobacco sold more were shikar (50%) and classic citrus (30%). Advertisement or promotion of sales was mainly in the form of signs and displays (53%). Major schools did not have any no tobacco boards displayed. Conclusion: Sale of tobacco continues in central Delhi with a lack of compliance with the rules of COPTA. The implications of this non compliance in the Capital region is of major significance for the rest of the country. PMID:28345846

  14. A deepwater fish with ‘lightsabers’ – dorsal spine-associated luminescence in a counterilluminating lanternshark

    PubMed Central

    Claes, Julien M.; Dean, Mason N.; Nilsson, Dan-Eric; Hart, Nathan S.; Mallefet, Jérôme

    2013-01-01

    We report the discovery of light organs (photophores) adjacent to the dorsal defensive spines of a small deep-sea lanternshark (Etmopterus spinax). Using a visual modeling based on in vivo luminescence recordings we show that this unusual light display would be detectable by the shark's potential predators from several meters away. We also demonstrate that the luminescence from the spine-associated photophores (SAPs) can be seen through the mineralized spines, which are partially translucent. These results suggest that the SAPs function, either by mimicking the spines' shape or by shining through them, as a unique visual deterrent for predators. This conspicuous dorsal warning display is a surprising complement to the ventral luminous camouflage (counterillumination) of the shark. PMID:23425862

  15. A deepwater fish with 'lightsabers'--dorsal spine-associated luminescence in a counterilluminating lanternshark.

    PubMed

    Claes, Julien M; Dean, Mason N; Nilsson, Dan-Eric; Hart, Nathan S; Mallefet, Jérôme

    2013-01-01

    We report the discovery of light organs (photophores) adjacent to the dorsal defensive spines of a small deep-sea lanternshark (Etmopterus spinax). Using a visual modeling based on in vivo luminescence recordings we show that this unusual light display would be detectable by the shark's potential predators from several meters away. We also demonstrate that the luminescence from the spine-associated photophores (SAPs) can be seen through the mineralized spines, which are partially translucent. These results suggest that the SAPs function, either by mimicking the spines' shape or by shining through them, as a unique visual deterrent for predators. This conspicuous dorsal warning display is a surprising complement to the ventral luminous camouflage (counterillumination) of the shark.

  16. Developing Remote Sensing Capabilities for Meter-Scale Sea Ice Properties

    DTIC Science & Technology

    2013-09-30

    such as MODIS . APPROACH 1. Task and acquire high resolution panchromatic and multispectral optical (e.g. Quickbird, Worldview, National Assets...does not display a currently valid OMB control number. 1. REPORT DATE 30 SEP 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00-2013 4...cloud cover , an excessive percentage of the imagery acquired over drifting sites was cloud covered , and the vendor did not delay acquisitions or

  17. An Improved Electro-Optical Image Quality Summary Measure.

    DTIC Science & Technology

    1981-10-01

    photo- graphing the display of a vidicon camera system viewing silhouettes of the broadside view of a Soviet KOTLIN class destroyer. Observers were...series ,: hard mages. Transparencies of the broadside KOTLIN silhouette were made with the scale :actor ranqin,, from 13b to 1810 meters per picture...3 warship rather than a merchant ship, and (c) the warsh-,;, is identifiable as beinq )f the nDTLIN class. Obviously, since only KOTLIN images were

  18. Digital Receiver Phase Meter

    NASA Technical Reports Server (NTRS)

    Marcin, Martin; Abramovici, Alexander

    2008-01-01

    The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

  19. Elbow mass flow meter

    DOEpatents

    McFarland, Andrew R.; Rodgers, John C.; Ortiz, Carlos A.; Nelson, David C.

    1994-01-01

    Elbow mass flow meter. The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity.

  20. Thirty Meter Telescope (TMT) Narrow Field Infrared Adaptive Optics System (NFIRAOS) real-time controller preliminary architecture

    NASA Astrophysics Data System (ADS)

    Kerley, Dan; Smith, Malcolm; Dunn, Jennifer; Herriot, Glen; Véran, Jean-Pierre; Boyer, Corinne; Ellerbroek, Brent; Gilles, Luc; Wang, Lianqi

    2016-08-01

    The Narrow Field Infrared Adaptive Optics System (NFIRAOS) is the first light Adaptive Optics (AO) system for the Thirty Meter Telescope (TMT). A critical component of NFIRAOS is the Real-Time Controller (RTC) subsystem which provides real-time wavefront correction by processing wavefront information to compute Deformable Mirror (DM) and Tip/Tilt Stage (TTS) commands. The National Research Council of Canada - Herzberg (NRC-H), in conjunction with TMT, has developed a preliminary design for the NFIRAOS RTC. The preliminary architecture for the RTC is comprised of several Linux-based servers. These servers are assigned various roles including: the High-Order Processing (HOP) servers, the Wavefront Corrector Controller (WCC) server, the Telemetry Engineering Display (TED) server, the Persistent Telemetry Storage (PTS) server, and additional testing and spare servers. There are up to six HOP servers that accept high-order wavefront pixels, and perform parallelized pixel processing and wavefront reconstruction to produce wavefront corrector error vectors. The WCC server performs low-order mode processing, and synchronizes and aggregates the high-order wavefront corrector error vectors from the HOP servers to generate wavefront corrector commands. The Telemetry Engineering Display (TED) server is the RTC interface to TMT and other subsystems. The TED server receives all external commands and dispatches them to the rest of the RTC servers and is responsible for aggregating several offloading and telemetry values that are reported to other subsystems within NFIRAOS and TMT. The TED server also provides the engineering GUIs and real-time displays. The Persistent Telemetry Storage (PTS) server contains fault tolerant data storage that receives and stores telemetry data, including data for Point-Spread Function Reconstruction (PSFR).

  1. Paragenesis of thermal denudation with gas-emission crater and lake formation, Yamal Peninsula, Russia

    NASA Astrophysics Data System (ADS)

    Babkina, Elena; Khomutov, Artem; Leibman, Marina; Dvornikov, Yury; Kizyakov, Alexander; Babkin, Evgeny

    2017-04-01

    Gas-emission craters (GECs) found in the North of West Siberia in 2014 occur in an area of wide tabular ground ice (TGI) distribution. TGI observed in the GEC walls also provokes thermal denudation: a complex of processes responsible for formation of thermocirques (TCs). TCs are semi-circle shaped depressions resulting from TGI thaw and removal of detached material downslope. Shores of many lakes are terraced and have ancient to recent traces of thermal denudation activity. TCs are numerous in the GEC area giving reason to assume that GEC, TGI, TC, and lakes are interrelated. First found Yamal crater (GEC-1) expanded from initial 18 m wide deep hole in 2013 to an irregularly-shaped lake up to 85 meters wide in 2016. Expansion of the GEC was controlled by TGI thaw. This can be considered in terms of thermal denudation and analyzed on the basis of TC study in the adjacent area. In summer 2014 and 2015 (the lifetime of the GEC-1) its wall retreat covered the area of 1730 square meters, which gives 865 square meters per year. In 2016, which was the warmest for the period of observation at weather station Marre-Sale, retreat area increased to 2200 square meters per year. TC, which exposed TGI similar to that in the walls of GEC-1, is observed on the nearest lakeshore. TC activation probably started in 2012 as elsewhere on Yamal. In 2015 its area according to GPS survey reached 4400 square meters (a four-year average 1100 square meters). Since September 2015 and till October 2016 its area expanded by 2600 square meters, thus increased by 59%, and more than twice compared to previous annual average. Lake adjacent to GEC-1 in 2016 was separated from crater edge by only a 13 meter wide isthmus, most likely both GEC-1 lake and adjacent lake merge in few years. Therefore, single basis of erosion for thermal denudation appear. After lakes merge, it would become hard to determine what the initial process for the lake formation was if not for the occasional discovery of the GEC-1. Thus, the rate of thermal denudation measured as area expansion: (a) inside the GEC was between 865 square meters per year in 2014-2015, and 2200 square meters in 2016, (b) on the adjacent lakeshore thermal denudation expanded by 1100 square meters per year in 2012-2015 and was as high as 2600 square meters in 2016. In both landforms higher rates were observed in the warmest 2016 and were rather similar. Lower rate for the GEC-1 at its initial stage is due to it steep slopes and narrow hole with little sunshine reaching lower parts of the hole. Adjacent lake providing basis of erosion for both features expands towards the GEC-1 lake and outside into tundra by thermal denudation activity and determines formation of a new feature: merged lake with components having different origin. This research is supported by Russian Science Foundation Grant 16-17-10203.

  2. AGE Bio Diesel Emissions Evaluation

    DTIC Science & Technology

    2003-12-01

    329 44 788 Vratd) Standard Meter Volume, m° 1.336 1.214 1.255 1,268 am Average Sampling Rate, dscfm 0786 0 714 0 739 0 746 P, Stack Pressure, inches...sat) Moisture (at saturation), % by volume 70864 248 8 36676 V.d Standard Water Vapor Volume, ft’ 2.198 1 624 1 911 1-B• Dry Mole Fraction 0 941 0946...Clock Meter Dry Gas Sample Time, Volume, Rotameter Meter Temp., Vacuum, Probe Time (min) (24-hr) (liter) Setting (OF) (in.Hg) jTpr, OF /o5 f / 52 / 6 14V_

  3. Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment

    NASA Technical Reports Server (NTRS)

    Brooker, John E.; Ruff, Gary A.

    2004-01-01

    The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.

  4. Assessing Tactical Scheduler Options for Time-Based Surface Metering

    NASA Technical Reports Server (NTRS)

    Zelinski, Shannon; Windhorst, Robert

    2017-01-01

    NASA is committed to demonstrating a concept of integrated arrival, departure, and surface operations by 2020 under the Airspace Technology Demonstration 2 (ATD2) sub-project. This will be accomplished starting with a demonstration of flight specific time-based departure metering at Charlotte Douglass International Airport (CLT). ATD2 tactical metering capability is based on NASAs Spot And Runway Departure Advisor (SARDA) which has been tested successfully in human-in-the-loop simulations of CLT. SARDA makes use of surface surveillance data and surface modeling to estimate the earliest takeoff time for each flight active on the airport surface or ready for pushback from the gate. The system then schedules each flight to its assigned runway in order of earliest takeoff time and assigns a target pushback time, displayed to ramp controllers as an advisory gate hold time. The objective of this method of departure metering is to move as much delay as possible to the gate to minimize surface congestion and engine on-time, while keeping sufficient pressure on the runway to maintain throughput. This flight specific approached enables greater flight efficiency and predictability, facilitating trajectory-based operations and surface-airspace integration, which ATD2 aims to achieve.Throughout ATD2 project formulation and system development, researchers have continuously engaged with stakeholders and future users, uncovering key system requirements for tactical metering that SARDA did not address. The SARDA scheduler is updated every 10 seconds using real-time surface surveillance data to ensure the most up-to-date information is used to predict runway usage. However, rapid updates also open the potential for fluctuating advisories, which Ramp controllers at a busy airport like CLT find unacceptable. Therefore, ATD2 tactical metering requires that all advisories freeze once flights are ready so that Ramp controllers may communicate a single hold time when responding to pilot ready calls.

  5. Solid state recording current meter conversion

    USGS Publications Warehouse

    Cheng, Ralph T.; Wang, Lichen

    1985-01-01

    The authors describe the conversion of an Endeco-174 current meter to a solid-state recording current meter. A removable solid-state module was designed to fit in the space originally occupied by an 8-track tape cartridge. The module contains a CPU and 128 kilobytes of nonvolatile CMOS memory. The solid-state module communicates with any terminal or computer using an RS-232C interface at 4800 baud rate. A primary consideration for conversion was to keep modifications of the current meter to a minimum. The communication protocol was designed to emulate the Endeco tape translation unit, thus the need for a translation unit was eliminated and the original data reduction programs can be used without any modification. After conversion, the data recording section of the current meter contains no moving parts; the storage capacity of the module is equivalent to that of the original tape cartridge.

  6. State of Louisiana - Highlighting low-lying areas derived from USGS Digital Elevation Data

    USGS Publications Warehouse

    Kosovich, John J.

    2008-01-01

    In support of U.S. Geological Survey (USGS) disaster preparedness efforts, this map depicts a color shaded relief representation highlighting the State of Louisiana and depicts the surrounding areas using muted elevation colors. The first 30 feet of relief above mean sea level are displayed as brightly colored 5-foot elevation bands, which highlight low-elevation areas at a coarse spatial resolution. Areas below sea level typically are surrounded by levees or some other type of flood-control structures. Standard USGS National Elevation Dataset (NED) 1 arc-second (nominally 30-meter) digital elevation model (DEM) data are the basis for the map, which is designed to be used at a broad scale and for informational purposes only. The NED data are a mixture of data and were derived from the original 1:24,000-scale USGS topographic map bare-earth contours, which were converted into gridded quadrangle-based DEM tiles at a constant post spacing (grid cell size) of either 30 meters (data before the mid-1990s) or 10 meters (mid-1990s and later data). These individual-quadrangle DEMs were then converted to spherical coordinates (latitude/longitude decimal degrees) and edge-matched to ensure seamlessness. Approximately one-half of the area shown on this map has DEM source data at a 30-meter resolution, with the remaining half consisting of mostly 10-meter contour-derived DEM data and some small areas of higher-resolution LIght Detection And Ranging (LIDAR) data along parts of the coastline. Areas below sea level typically are surrounded by levees or some other type of flood-control structures. State and parish boundary, hydrography, city, and road layers were modified from USGS National Atlas data downloaded in 2003. The NED data were downloaded in 2007.

  7. Orbital and physical characteristics of meter-scale impactors from airburst observations

    NASA Astrophysics Data System (ADS)

    Brown, P.; Wiegert, P.; Clark, D.; Tagliaferri, E.

    2016-03-01

    We have analyzed the orbits and ablation characteristics in the atmosphere of 59 Earth-impacting fireballs, produced by meteoroids 1 m in diameter or larger, described here as meter-scale. Using heights at peak luminosity as a proxy for strength, we determine that there is roughly an order of magnitude spread in strengths of the population of meter-scale impactors at the Earth. We use fireballs producing recovered meteorites and well documented fireballs from ground-based camera networks to calibrate our ablation model interpretation of the observed peak height of luminosity as a function of speed. The orbits and physical strength of these objects are consistent with the majority being asteroidal bodies originating from the inner main asteroid belt. This is in contrast to earlier suggestions by Ceplecha (Ceplecha, Z. [1994]. Astron. Astrophys. 286, 967-970) that the majority of meter-tens of meter sized meteoroids are ;… cometary bodies of the weakest known structure;. We find a lower limit of ∼10-15% of our objects have a possible cometary (Jupiter-Family comet and/or Halley-type comet) origin based on orbital characteristics alone. Only half this number, however, also show evidence for weaker than average structure. Two events, Sumava and USG 20131121, have exceptionally high (relative to the remainder of the population) heights of peak brightness. These are physically most consistent with high microporosity objects, though both were on asteroidal-type orbits. We also find three events, including the Oct 8, 2009 airburst near Sulawesi, Indonesia, which display comparatively low heights of peak brightness, consistent with strong monolithic stones or iron meteoroids. Based on orbital similarity, we find a probable connection among several events in our population with the Taurid meteoroid complex; no other major meteoroid streams show probable linkages to the orbits of our meter-scale population. Our impactors cover almost four orders of magnitude in mass, but no trend in height of peak brightness as a function of mass is evident, suggesting no strong trend in strength with size for meter-scale impactors consistent with the results of Popova et al. (Popova, O.P. et al. [2011]. Meteorit. Planet. Sci. 46, 1525-1550).

  8. Long-term cliff retreat and erosion hotspots along the central shores of the Monterey Bay National Marine Sanctuary

    USGS Publications Warehouse

    Moore, Laura J.; Griggs, Gary B.

    2002-01-01

    Quantification of cliff retreat rates for the southern half of Santa Cruz County, CA, USA, located within the Monterey Bay National Marine Sanctuary, using the softcopy/geographic information system (GIS) methodology results in average cliff retreat rates of 7–15 cm/yr between 1953 and 1994. The coastal dunes at the southern end of Santa Cruz County migrate seaward and landward through time and display net accretion between 1953 and 1994, which is partially due to development. In addition, three critically eroding segments of coastline with high average erosion rates ranging from 20 to 63 cm/yr are identified as erosion ‘hotspots’. These locations include: Opal Cliffs, Depot Hill and Manresa. Although cliff retreat is episodic, spatially variable at the scale of meters, and the factors affecting cliff retreat vary along the Santa Cruz County coastline, there is a compensation between factors affecting retreat such that over the long-term the coastline maintains a relatively smooth configuration. The softcopy/GIS methodology significantly reduces errors inherent in the calculation of retreat rates in high-relief areas (e.g. erosion rates generated in this study are generally correct to within 10 cm) by removing errors due to relief displacement. Although the resulting root mean squared error for erosion rates is relatively small, simple projections of past erosion rates are inadequate to provide predictions of future cliff position. Improved predictions can be made for individual coastal segments by using a mean erosion rate and the standard deviation as guides to future cliff behavior in combination with an understanding of processes acting along the coastal segments in question. This methodology can be applied on any high-relief coast where retreat rates can be measured.

  9. Spherical Harmonics Analysis of the ECMWF Global Wind Fields at the 10-Meter Height Level During 1985: A Collection of Figures Illustrating Results

    NASA Technical Reports Server (NTRS)

    Sanchez, Braulio V.; Nishihama, Masahiro

    1997-01-01

    Half-daily global wind speeds in the east-west (u) and north-south (v) directions at the 10-meter height level were obtained from the European Centre for Medium Range Weather Forecasts (ECMWF) data set of global analyses. The data set covered the period 1985 January to 1995 January. A spherical harmonic expansion to degree and order 50 was used to perform harmonic analysis of the east-west (u) and north-south (v) velocity field components. The resulting wind field is displayed, as well as the residual of the fit, at a particular time. The contribution of particular coefficients is shown. The time variability of the coefficients up to degree and order 3 is presented. Corresponding power spectrum plots are given. Time series analyses were applied also to the power associated with degrees 0-10; the results are included.

  10. Mount Kilimanjaro, Tanzania

    NASA Image and Video Library

    1996-01-20

    STS072-722-004 (11-20 Jan. 1996) --- Mount Kilimanjaro in Tanzania is featured in this 70mm frame exposed from the Earth-orbiting Space Shuttle Endeavour. Orient with the clouds trailing to the left; then the view is southwest from Kenya past Kilimanjaro to Mount Meru, in Tanzania. Mount Kilimanjaro is about three degrees south of the Equator, but at nearly 6,000 meters has a permanent snowfield. The mountain displays a classic zonation of vegetation types from seasonally dry savannah on the plains at 1,000 meters, to the cloud forest near the top. The mountain is being managed experimentally as an international biosphere reserve. A buffer zone of "traditional" agriculture and pastoral land use is designated around the closed-canopy forest reserve. Specialists familiar with this area say management is partially successful so far, but cleared areas of the forest can be seen on this photograph as light green "nibbles" or "cookie cuts" extending into the dark forest region.

  11. Thermal study of the Missouri River in North Dakota using infrared imagery

    NASA Technical Reports Server (NTRS)

    Crosby, O. A.

    1971-01-01

    Studies of infrared imagery obtained from aircraft at 305- to 1,524-meter altitudes indicate the feasibility of monitoring thermal changes attributable to the operation of thermal electric plants and storage reservoirs, as well as natural phenomena such as tributary inflow and ground water seeps in large rivers. No identifiable sources of ground water inflow below the surface of the river could be found in the imagery. The thermal patterns from the generating plants and the major tributary inflow are readily apparent in imagery obtained from an altitude of 305 meters. Portions of the tape-recorded imagery were processed in a color-coded quantization to enhance the displays and to attach quantitative significance to the data. The study indicates a marked decrease in water temperature in the Missouri River prior to early fall and a moderate increase in temperature in late fall because of the Lake Sakakawea impoundment.

  12. Fabrication and evaluation of a graphene oxide-based cantilever-type flow-meter for subsonic gas flow rate measurement

    NASA Astrophysics Data System (ADS)

    Hamdollahi, Hassan; Rahbar-Shahrouzi, Javad

    2018-05-01

    In this paper, a cantilever-type flow meter was fabricated to measure the rate of air flow in turbulent subsonic regimes such as purged gases. In the fabrication process, a piezoresistive material was coated on an interdigitated electric board as a substrate. The piezoresistive layer was a blend of latex as the polymeric matrix and graphene oxide as the sensing nanomaterial agent, which was reduced by solvothermal reduction method. The piezoresistive blend was dip-coated on a substrate with dotted pattern and was then reduced at 240 °C for 1 h in every coating step. When an air flow passed over the surface of the cantilever beam, the beam was bent in the downward direction, resulting in small variations in the resistance of the piezoresistive layer and a change in the bending angle of the cantilever which were measured simultaneously. The air flow rate was acquired via calibrating electrical resistance changes by Arduino and Wheatstone bridge circuit. The blending angle of the substrate caused by the interaction between the airflow and the cantilever and recorded by the camera and image processing was ultimately compared with the simulation results. The flow meter accuracy as a percentage of full scale (% FS) was calculated to be  ±5.8%, and mean deviation was equal to 2.1 (% FS) with the appropriate response time of 0.70 s at the air flow range of 100‑240 m s‑1. Highlights • A cantilever-type flow meter was fabricated to measure the high-speed air flow rate. • The sensitive piezoresistive material was composed of GO and latex. • The dip-coating method was used to deposit the piezoresistive layer on the fiberglass substrate. • The impact of effective parameters on the performance of the flow meter was investigated. • A simulation study was performed and the results were compared with the experimental data.

  13. 46 CFR 34.20-5 - Quantity of foam required-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... to give primary protection to the spaces over the cargo tanks. (b) Rate of application. The water... liters/min per square meter of cargo tanks deck area, where cargo tanks deck area means the maximum.../min per square meter of the horizontal sectional area of the single tank having the largest such area...

  14. Assessment of exposure to radio frequency electromagnetic fields from smart utility meters in GB; part II) numerical assessment of induced SAR within the human body.

    PubMed

    Qureshi, Muhammad R A; Alfadhl, Yasir; Chen, Xiaodong; Peyman, Azadeh; Maslanyj, Myron; Mann, Simon

    2018-04-01

    Human body exposure to radiofrequency electromagnetic waves emitted from smart meters was assessed using various exposure configurations. Specific energy absorption rate distributions were determined using three anatomically realistic human models. Each model was assigned with age- and frequency-dependent dielectric properties representing a collection of age groups. Generalized exposure conditions involving standing and sleeping postures were assessed for a home area network operating at 868 and 2,450 MHz. The smart meter antenna was fed with 1 W power input which is an overestimation of what real devices typically emit (15 mW max limit). The highest observed whole body specific energy absorption rate value was 1.87 mW kg -1 , within the child model at a distance of 15 cm from a 2,450 MHz device. The higher values were attributed to differences in dimension and dielectric properties within the model. Specific absorption rate (SAR) values were also estimated based on power density levels derived from electric field strength measurements made at various distances from smart meter devices. All the calculated SAR values were found to be very small in comparison to International Commission on Non-Ionizing Radiation Protection limits for public exposure. Bioelectromagnetics. 39:200-216, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. Coarse-clast ridge complexes of the Caribbean: A preliminary basis for distinguishing tsunami and storm-wave origins

    USGS Publications Warehouse

    Morton, R.A.; Richmond, B.M.; Jaffe, B.E.; Gelfenbaum, G.

    2008-01-01

    Coastal gravel-ridge complexes deposited on islands in the Caribbean Sea are recorders of past extreme-wave events that could be associated with either tsunamis or hurricanes. The ridge complexes of Bonaire, Jamaica, Puerto Rico (Isla de Mona), and Guadeloupe consist of polymodal clasts ranging in size from sand to coarse boulders that are derived from the adjacent coral reefs or subjacent rock platforms. Ridge-complex morphologies and crest elevations are largely controlled by availability of sediments, clast sizes, and heights of wave runup. The ridge complexes are internally organized, display textural sorting and a broad range of ages including historical events. Some display seaward-dipping beds and ridge-and-swale topography, and some terminate in fans or steep avalanche slopes. Together, the morphologic, sedimentologic, lithostratigraphic, and chronostratigraphic evidence indicates that shore-parallet ridge complexes composed of gravel and sand that are tens of meters wide and several meters thick are primarily storm-constructed features that have accumulated for a few centuries or millennia as a result of multiple high-frequency intense-wave events. They are not entirely the result of one or a few tsunamis as recently reported. Tsunami deposition may account for some of the lateral ridge-complex accretion or boulder fields and isolated blocks that are associated with the ridge complexes. Copyright ?? 2008, SEPM (Society for Sedimentary Geology).

  16. Characterization of geologic deposits in the vicinity of US Ecology, Amargosa Basin, southern Nevada

    USGS Publications Warehouse

    Taylor, Emily M.

    2010-01-01

    Multiple approaches have been applied to better understand the characteristics of geologic units exposed at the surface and buried at depth in the vicinity of US Ecology (USE), a low-level commercial waste site in the northern Amargosa Desert, Nevada. Techniques include surficial geologic mapping and interpretation of the subsurface using borehole data. Dated deposits at depth were used to estimate rates of sediment accumulation. The subsurface lithologies have been modeled in three dimensions. Lithologic cross sections have been created from the three-dimensional model and have been compared to resistivity data at the same location. Where deposits appear offset, a fault was suspected. Global Positioning System elevation transects were measured and trenches were excavated to locate a strand of the Carrara Fault. The presence of the fault helps to better understand the shape of the potentiometric surface. These data will be used to better understand the hydrologic parameters controlling the containment of the waste at US Ecology.Quaternary geologic units exposed at the surface, in the vicinity of US Ecology, are derived from the alluvium shed off the adjacent range front and the Amargosa River. These deposits vary from modern to early Pleistocene in age. At depth, heterogeneous sands and gravel occur. Observed in deep trenches and boreholes, the subsurface deposits are characterized as fining-upward sequence of sediment from 5- to 8-meters thick. No volcanic units or fine-grained playa deposits were described in the boreholes to a depth of 200 meters. Based on Infrared Stimulated Luminescence dated core samples, short-term rates of sediment accumulation (<70,000 years) are an average of 2.7 millimeters per year, however, long-term rates (<3,900,000 years) are orders of magnitude less. Resistivity data, when compared to lithologic cross sections, generally are consistent with lithology grain size and probable soil carbonate accumulations. Surface resistivity displays a fining-upward sequence of sediments at the surface with a soil carbonate imprint. Finally, trenching north of US Ecology successfully exposed offset Quaternary deposits on a splay of the Carrara Fault. Holocene deposits do not appear to be faulted, however, a fault zone does intersect middle and late Pleistocene aged units.

  17. "Watch out!": Effects of instructed threat and avoidance on human free-operant approach-avoidance behavior.

    PubMed

    Schlund, Michael W; Treacher, Kay; Preston, Oli; Magee, Sandy K; Richman, David M; Brewer, Adam T; Cameron, Gemma; Dymond, Simon

    2017-01-01

    Approach-avoidance paradigms create a competition between appetitive and aversive contingencies and are widely used in nonhuman research on anxiety. Here, we examined how instructions about threat and avoidance impact control by competing contingencies over human approach-avoidance behavior. Additionally, Experiment 1 examined the effects of threat magnitude (money loss amount) and avoidance cost (fixed ratio requirements), whereas Experiment 2 examined the effects of threat information (available, unavailable and inaccurate) on approach-avoidance. During the task, approach responding was modeled by reinforcing responding with money on a FR schedule. By performing an observing response, participants produced an escalating "threat meter". Instructions stated that the threat meter levels displayed the current probability of losing money, when in fact loss only occurred when the level reached the maximum. Instructions also stated pressing an avoidance button lowered the threat level. Overall, instructions produced cycles of approach and avoidance responding with transitions from approach to avoidance when threat was high and transitions back to approach after avoidance reduced threat. Experiment 1 revealed increasing avoidance cost, but not threat magnitude, shifted approach-avoidance transitions to higher threat levels and increased anxiety ratings, but did not influence the frequency of approach-avoidance cycles. Experiment 2 revealed when threat level information was available or absent earnings were high, but earnings decreased when inaccurate threat information was incompatible with contingencies. Our findings build on prior nonhuman and human approach-avoidance research by highlighting how instructed threat and avoidance can impact human AA behavior and self-reported anxiety. © 2017 Society for the Experimental Analysis of Behavior.

  18. Gas flow meter and method for measuring gas flow rate

    DOEpatents

    Robertson, Eric P.

    2006-08-01

    A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.

  19. The use of earthquake rate changes as a stress meter at Kilauea volcano.

    PubMed

    Dieterich, J; Cayol, V; Okubo, P

    2000-11-23

    Stress changes in the Earth's crust are generally estimated from model calculations that use near-surface deformation as an observational constraint. But the widespread correlation of changes of earthquake activity with stress has led to suggestions that stress changes might be calculated from earthquake occurrence rates obtained from seismicity catalogues. Although this possibility has considerable appeal, because seismicity data are routinely collected and have good spatial and temporal resolution, the method has not yet proven successful, owing to the non-linearity of earthquake rate changes with respect to both stress and time. Here, however, we present two methods for inverting earthquake rate data to infer stress changes, using a formulation for the stress- and time-dependence of earthquake rates. Application of these methods at Kilauea volcano, in Hawaii, yields good agreement with independent estimates, indicating that earthquake rates can provide a practical remote-sensing stress meter.

  20. Recent and relict topography of Boo Bee patch reef, Belize

    USGS Publications Warehouse

    Halley, R.B.; Shinn, E.A.; Hudson, J.H.; Lidz, B.; Taylor, D.L.

    1977-01-01

    Five core borings were taken on and around Boo Bee Patch Reef to better understand the origin of such shelf lagoon reefs. The cores reveal 4 stages of development: (1) subaerial exposure of a Pleistocene "high" having about 8 meters of relief, possibly a Pleistocene patch reef; (2) deposition of peat and impermeable terrigenous clay 3 meters thick around the high; (3) initiation of carbonate sediment production by corals and algae on the remaining 5 meters of hard Pleistocene topography and carbonate mud on the surrounding terrigenous clay; and (4) accelerated organic accumulation on the patch reef. Estimates of patch reef sedimentation rates (1.6 m/1000 years) are 3 to 4 times greater than off-reef sedimentation rates (0.4-0.5 m/1000 years). During periods of Pleistocene sedimentation on the Belize shelf, lagoon patch reefs may have grown above one another, stacking up to form reef accumulation of considerable thickness.

  1. Distribution and transport of polychlorinated biphenyls in Little Lake Butte des Morts, Fox River, Wisconsin, April 1987-October 1988

    USGS Publications Warehouse

    House, L.B.

    1995-01-01

    The mass of PCB's transported from the lake in streamflow during 1987-88 was calculated to be 110 kilograms annually. The PCB's transport rate decreased 50 percent from 1987 to 1988, for the period April through September. Transport of PCB's was greatest during April and May of each year. The average flux rate of PCB's into the water column from the bottom sediment in the lake was estimated to be 1.2 milligrams per square meter per day. The PCB's load seems to increase at river discharges greater than 212 cubic meters per second. This increase in PCB's load might be caused by resuspension of PCB's-contaminated bottom-sediment deposits. There was little variation in PCB's load at flows less than 170 cubic meters per second. The bottom sediments are a continuing source of PCB's to Little Lake Butte des Morts and the lower Fox River.

  2. Information transfer rate with serial and simultaneous visual display formats

    NASA Astrophysics Data System (ADS)

    Matin, Ethel; Boff, Kenneth R.

    1988-04-01

    Information communication rate for a conventional display with three spatially separated windows was compared with rate for a serial display in which data frames were presented sequentially in one window. For both methods, each frame contained a randomly selected digit with various amounts of additional display 'clutter.' Subjects recalled the digits in a prescribed order. Large rate differences were found, with faster serial communication for all levels of the clutter factors. However, the rate difference was most pronounced for highly cluttered displays. An explanation for the latter effect in terms of visual masking in the retinal periphery was supported by the results of a second experiment. The working hypothesis that serial displays can speed information transfer for automatic but not for controlled processing is discussed.

  3. NGST Yardstick Integrated Science Instrument Module (ISIM) Feasibility Study

    NASA Astrophysics Data System (ADS)

    Greenhouse, M. A.; Dipirro, M.; Federline, B.; Gardner, Jonathan P.; Guy, P.; Hagopian, J.; Hein, J.; Jurotich, M.; Lawrence, J.; Martineau, B.; Mather, J. C.; Mentzell, E.; Satyapal, S.; Stanley, D.; Teplitz, H. I.; Travis, J.; Bely, P.; Petro, L. D.; Stockman, P.; Burg, R.; Bitzel, R.

    1998-12-01

    We display portions of the baseline design concept for the NGST Integrated Science Instrument Module (ISIM). This ISIM design is under ongoing development for integration with the "Yardstick" and other NGST 8 m architectures that are intended for packaging in an EELV or Ariane 5 meter class fairing. The goals of this activity are to: [1] demonstrate mission science feasibility, [2] identify ISIM technology challenge areas, [3] assess ISIM engineering and cost feasibility, [5] identify ISIM/NGST interface constraints, and [6] enable smart customer procurement of the ISIM. In this poster, we display a snap shot of work in progress including: optical design, opto-mechanical layout, thermal modeling, focal plane array design, and electronics design. Ongoing progress can be monitored via ISIM team web site: http://ngst.gsfc.nasa.gov/

  4. Future opportunities for advancing glucose test device electronics.

    PubMed

    Young, Brian R; Young, Teresa L; Joyce, Margaret K; Kennedy, Spencer I; Atashbar, Massood Z

    2011-09-01

    Advancements in the field of printed electronics can be applied to the field of diabetes testing. A brief history and some new developments in printed electronics components applicable to personal test devices, including circuitry, batteries, transmission devices, displays, and sensors, are presented. Low-cost, thin, and lightweight materials containing printed circuits with energy storage or harvest capability and reactive/display centers, made using new printing/imaging technologies, are ideal for incorporation into personal-use medical devices such as glucose test meters. Semicontinuous rotogravure printing, which utilizes flexible substrates and polymeric, metallic, and/or nano "ink" composite materials to effect rapidly produced, lower-cost printed electronics, is showing promise. Continuing research advancing substrate, "ink," and continuous processing development presents the opportunity for research collaboration with medical device designers. © 2011 Diabetes Technology Society.

  5. Redundancy in Glucose Sensing

    PubMed Central

    Sharifi, Amin; Varsavsky, Andrea; Ulloa, Johanna; Horsburgh, Jodie C.; McAuley, Sybil A.; Krishnamurthy, Balasubramanian; Jenkins, Alicia J.; Colman, Peter G.; Ward, Glenn M.; MacIsaac, Richard J.; Shah, Rajiv; O’Neal, David N.

    2015-01-01

    Background: Current electrochemical glucose sensors use a single electrode. Multiple electrodes (redundancy) may enhance sensor performance. We evaluated an electrochemical redundant sensor (ERS) incorporating two working electrodes (WE1 and WE2) onto a single subcutaneous insertion platform with a processing algorithm providing a single real-time continuous glucose measure. Methods: Twenty-three adults with type 1 diabetes each wore two ERSs concurrently for 168 hours. Post-insertion a frequent sampling test (FST) was performed with ERS benchmarked against a glucose meter (Bayer Contour Link). Day 4 and 7 FSTs were performed with a standard meal and venous blood collected for reference glucose measurements (YSI and meter). Between visits, ERS was worn with capillary blood glucose testing ≥8 times/day. Sensor glucose data were processed prospectively. Results: Mean absolute relative deviation (MARD) for ERS day 1-7 (3,297 paired points with glucose meter) was (mean [SD]) 10.1 [11.5]% versus 11.4 [11.9]% for WE1 and 12.0 [11.9]% for WE2; P < .0001. ERS Clarke A and A+B were 90.2% and 99.8%, respectively. ERS day 4 plus day 7 MARD (1,237 pairs with YSI) was 9.4 [9.5]% versus 9.6 [9.7]% for WE1 and 9.9 [9.7]% for WE2; P = ns. ERS day 1-7 precision absolute relative deviation (PARD) was 9.9 [3.6]% versus 11.5 [6.2]% for WE1 and 10.1 [4.4]% for WE2; P = ns. ERS sensor display time was 97.8 [6.0]% versus 91.0 [22.3]% for WE1 and 94.1 [14.3]% for WE2; P < .05. Conclusions: Electrochemical redundancy enhances glucose sensor accuracy and display time compared with each individual sensing element alone. ERS performance compares favorably with ‘best-in-class’ of non-redundant sensors. PMID:26499476

  6. Redundancy in Glucose Sensing: Enhanced Accuracy and Reliability of an Electrochemical Redundant Sensor for Continuous Glucose Monitoring.

    PubMed

    Sharifi, Amin; Varsavsky, Andrea; Ulloa, Johanna; Horsburgh, Jodie C; McAuley, Sybil A; Krishnamurthy, Balasubramanian; Jenkins, Alicia J; Colman, Peter G; Ward, Glenn M; MacIsaac, Richard J; Shah, Rajiv; O'Neal, David N

    2016-05-01

    Current electrochemical glucose sensors use a single electrode. Multiple electrodes (redundancy) may enhance sensor performance. We evaluated an electrochemical redundant sensor (ERS) incorporating two working electrodes (WE1 and WE2) onto a single subcutaneous insertion platform with a processing algorithm providing a single real-time continuous glucose measure. Twenty-three adults with type 1 diabetes each wore two ERSs concurrently for 168 hours. Post-insertion a frequent sampling test (FST) was performed with ERS benchmarked against a glucose meter (Bayer Contour Link). Day 4 and 7 FSTs were performed with a standard meal and venous blood collected for reference glucose measurements (YSI and meter). Between visits, ERS was worn with capillary blood glucose testing ≥8 times/day. Sensor glucose data were processed prospectively. Mean absolute relative deviation (MARD) for ERS day 1-7 (3,297 paired points with glucose meter) was (mean [SD]) 10.1 [11.5]% versus 11.4 [11.9]% for WE1 and 12.0 [11.9]% for WE2; P < .0001. ERS Clarke A and A+B were 90.2% and 99.8%, respectively. ERS day 4 plus day 7 MARD (1,237 pairs with YSI) was 9.4 [9.5]% versus 9.6 [9.7]% for WE1 and 9.9 [9.7]% for WE2; P = ns. ERS day 1-7 precision absolute relative deviation (PARD) was 9.9 [3.6]% versus 11.5 [6.2]% for WE1 and 10.1 [4.4]% for WE2; P = ns. ERS sensor display time was 97.8 [6.0]% versus 91.0 [22.3]% for WE1 and 94.1 [14.3]% for WE2; P < .05. Electrochemical redundancy enhances glucose sensor accuracy and display time compared with each individual sensing element alone. ERS performance compares favorably with 'best-in-class' of non-redundant sensors. © 2015 Diabetes Technology Society.

  7. Advection within shallow pore waters of a coastal lagoon, Florida

    USGS Publications Warehouse

    Cable, J.E.; Martin, Jonathan B.; Swarzenski, Peter W.; Lindenberg, Mary K.; Steward, Joel

    2004-01-01

    Ground water sources can be a significant portion of a local water budget in estuarine environments, particularly in areas with high recharge rates, transmissive aquifers, and permeable marine sediments. However, field measurements of ground water discharge are often incongruent with ground water flow modeling results, leaving many scientists unsure which estimates are accurate. In this study, we find that both measurements and model results are reasonable. The difference between estimates apparently results from the sources of water being measured and not the techniques themselves. In two locations in the Indian River Lagoon estuarine system, we found seepage meter rates similar to rates calculated from the geochemical tracers 222Rn and 226Ra. Ground water discharge rates ranged from 4 to 9 cm/d using seepage meters and 3 to 20 cm/d using 222Rn and 226Ra. In contrast, in comparisons to other studies where finite element ground water flow modeling was used, much lower ground water discharge rates of ∼0.05 to 0.15 cm/d were estimated. These low rates probably represent discharge of meteoric ground water from land-recharged aquifers, while the much higher rates measured with seepage meters, 222Rn, and 226Ra likely include an additional source of surface waters that regularly flush shallow (< 1 m depth) sediments. This resultant total flow of mixed land-recharged water and recirculated surface waters contributes to the total biogeochemical loading in this shallow estuarine environment.

  8. 40 CFR 49.125 - Rule for limiting the emissions of particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... used exclusively for space heating with a rated heat input capacity of less than 400,000 British... average of 0.23 grams per dry standard cubic meter (0.1 grains per dry standard cubic foot), corrected to... boiler stack must not exceed an average of 0.46 grams per dry standard cubic meter (0.2 grains per dry...

  9. 76 FR 61183 - Loveland Area Projects-Western Area Colorado Missouri Balancing Authority-Rate Order No. WAPA-155

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-03

    ... metered load settled using WACM hourly pricing with no using WACM hourly pricing with no penalty. penalty... metered load settled using pricing in no-penalty band. Customer WACM hourly pricing with a 25% penalty... or equal to 0.5 percent of its hourly average load, no Regulation Service charges will be assessed by...

  10. Tuning time-frequency methods for the detection of metered HF speech

    NASA Astrophysics Data System (ADS)

    Nelson, Douglas J.; Smith, Lawrence H.

    2002-12-01

    Speech is metered if the stresses occur at a nearly regular rate. Metered speech is common in poetry, and it can occur naturally in speech, if the speaker is spelling a word or reciting words or numbers from a list. In radio communications, the CQ request, call sign and other codes are frequently metered. In tactical communications and air traffic control, location, heading and identification codes may be metered. Moreover metering may be expected to survive even in HF communications, which are corrupted by noise, interference and mistuning. For this environment, speech recognition and conventional machine-based methods are not effective. We describe Time-Frequency methods which have been adapted successfully to the problem of mitigation of HF signal conditions and detection of metered speech. These methods are based on modeled time and frequency correlation properties of nearly harmonic functions. We derive these properties and demonstrate a performance gain over conventional correlation and spectral methods. Finally, in addressing the problem of HF single sideband (SSB) communications, the problems of carrier mistuning, interfering signals, such as manual Morse, and fast automatic gain control (AGC) must be addressed. We demonstrate simple methods which may be used to blindly mitigate mistuning and narrowband interference, and effectively invert the fast automatic gain function.

  11. Laser power meters as an X-ray power diagnostic for LCLS-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heimann, Philip; Moeller, Stefan; Carbajo, Sergio

    For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. Here, a number of characteristicsmore » in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.« less

  12. Use of an Electromagnetic Seepage Meter to Investigate Temporal Variability in Lake Seepage

    USGS Publications Warehouse

    Rosenberry, D.O.; Morin, R.H.

    2004-01-01

    A commercially available electromagnetic flowmeter is attached to a seepage cylinder to create an electromagnetic seepage meter (ESM) for automating measurement of fluxes across the sediment/water interface between ground water and surface water. The ESM is evaluated through its application at two lakes in New England, one where water seeps into the lake and one where water seeps out of the lake. The electromagnetic flowmeter replaces the seepage-meter bag and provides a continuous series of measurements from which temporal seepage processes can be investigated. It provides flow measurements over a range of three orders of magnitude, and contains no protruding components or moving parts. The ESM was used to evaluate duration of seepage disturbance following meter installation and indicated natural seepage rates resumed approximately one hour following meter insertion in a sandy lakebed. Lakebed seepage also varied considerably in response to lakebed disturbances, near-shore waves, and rain-falls, indicating hydrologic processes are occurring in shallow lakebed settings at time scales that have largely gone unobserved.

  13. MethylMeter(®): bisulfite-free quantitative and sensitive DNA methylation profiling and mutation detection in FFPE samples.

    PubMed

    McCarthy, David; Pulverer, Walter; Weinhaeusel, Andreas; Diago, Oscar R; Hogan, Daniel J; Ostertag, Derek; Hanna, Michelle M

    2016-06-01

    Development of a sensitive method for DNA methylation profiling and associated mutation detection in clinical samples. Formalin-fixed and paraffin-embedded tumors received by clinical laboratories often contain insufficient DNA for analysis with bisulfite or methylation sensitive restriction enzymes-based methods. To increase sensitivity, methyl-CpG DNA capture and Coupled Abscription PCR Signaling detection were combined in a new assay, MethylMeter(®). Gliomas were analyzed for MGMT methylation, glioma CpG island methylator phenotype and IDH1 R132H. MethylMeter had 100% assay success rate measuring all five biomarkers in formalin-fixed and paraffin-embedded tissue. MGMT methylation results were supported by survival and mRNA expression data. MethylMeter is a sensitive and quantitative method for multitarget DNA methylation profiling and associated mutation detection. The MethylMeter-based GliomaSTRAT assay measures methylation of four targets and one mutation to simultaneously grade gliomas and predict their response to temozolomide. This information is clinically valuable in management of gliomas.

  14. Transcutaneous measurement of hyperbilirubinaemia: comparison of the Minolta jaundice meter and the Ingram icterometer.

    PubMed

    Bilgen, H; Ince, Z; Ozek, E; Bekiroglu, N; Ors, R

    1998-12-01

    The effectiveness of two different non-invasive transcutaneous bilirubin measurement devices was compared with serum bilirubin levels in 96 healthy newborns. Transcutaneous measurements were obtained with the Minolta Air Shields jaundice meter and the Ingram icterometer and serum bilirubin levels were determined by a direct spectrophotometric method (Bilitron 444). A linear correlation existed between serum bilirubin values and the readings on both the Minolta jaundice meter (r = 0.83) and the Ingram icterometer (r = 0.78). The Kappa coefficient was 0.66. the sensitivity, specificity and positive and negative predictive values were 100%, 56%, 33% and 100% for the Minolta jaundice meter and 100%, 48%, 29% and 100% for the Ingram icterometer, respectively. The high sensitivity and negative predictive value of both devices render them suitable for screening neonatal hyperbilirubinaemia. However, because of its low cost, the Ingram icterometer is preferable to the more complex and expensive Minolta jaundice meter, especially in countries with a high birth rate, such as Turkey.

  15. Sedimentation Survey of Lago El Guineo, Puerto Rico, October 2001

    USGS Publications Warehouse

    Soler-López, Luis R.

    2003-01-01

    Lago El Guineo has lost about 17.5 percent of its original storage capacity in 70 years because of sediment accumulation. The water volume has been reduced from 2.29 million cubic meters in 1931, to 2.03 million cubic meters in 1986, and to 1.89 million cubic meters in 2001. The average annual storage-capacity loss (equal to the sedimentation rate) of Lago El Guineo was 4,727 cubic meters for the period of 1931 to July 1986 (or 0.21 percent per year), increasing to 5,714 cubic meters for the period of 1931 to October 2001 (or 0.25 percent per year). Discrepancies that could lead to substantial errors in volume calculations in a small reservoir like Lago El Guineo, were found when transferring the field-collected data into the geographic information system data base 1:20,000 U.S. Geological Survey Jayuya, Puerto Rico quadrangle. After verification and validation of field data, the Lago El Guineo shoreline was rectified using digital aerial photographs and differential global positioning data.

  16. Use of an electromagnetic seepage meter to investigate temporal variability in lake seepage.

    PubMed

    Rosenberry, Donald O; Morin, Roger H

    2004-01-01

    A commercially available electromagnetic flowmeter is attached to a seepage cylinder to create an electromagnetic seepage meter (ESM) for automating measurement of fluxes across the sediment/water interface between ground water and surface water. The ESM is evaluated through its application at two lakes in New England, one where water seeps into the lake and one where water seeps out of the lake. The electromagnetic flowmeter replaces the seepage-meter bag and provides a continuous series of measurements from which temporal seepage processes can be investigated. It provides flow measurements over a range of three orders of magnitude, and contains no protruding components or moving parts. The ESM was used to evaluate duration of seepage disturbance following meter installation and indicated natural seepage rates resumed approximately one hour following meter insertion in a sandy lakebed. Lakebed seepage also varied considerably in response to lakebed disturbances, near-shore waves, and rainfalls, indicating hydrologic processes are occurring in shallow lakebed settings at time scales that have largely gone unobserved.

  17. Laser power meters as an X-ray power diagnostic for LCLS-II.

    PubMed

    Heimann, Philip; Moeller, Stefan; Carbajo, Sergio; Song, Sanghoon; Dakovski, Georgi; Nordlund, Dennis; Fritz, David

    2018-01-01

    For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. A number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

  18. Laser power meters as an X-ray power diagnostic for LCLS-II

    DOE PAGES

    Heimann, Philip; Moeller, Stefan; Carbajo, Sergio; ...

    2018-01-01

    For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. Here, a number of characteristicsmore » in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.« less

  19. Exposure of Water Ice in the Northern Mid-lattitudes of Mars

    NASA Technical Reports Server (NTRS)

    Allen, Carlton C.; Kanner, Lisa C.

    2007-01-01

    Water ice is exposed in the martian north polar cap, and is occasionally exposed beyond the cap boundary. Orbital gamma ray spectrometry data strongly imply the presence of water ice within meters of the surface at latitudes north of approximately 60 deg. We have examined midlatitude areas of the northern plains displaying evidence of residual ice-rich layers, and report possible present-day exposures of ice. These exposures, if confirmed, could constrain the latitudinal and temporal stability of surface ice on Mars.

  20. Sampling protocol recommendations for measuring soil organic carbon stocks in the tropics

    NASA Astrophysics Data System (ADS)

    van Straaten, Oliver; Veldkamp, Edzo; Corre, Marife D.

    2013-04-01

    In the tropics, there is an urgent need for cost effective sampling approaches to quantify soil organic carbon (SOC) changes associated with land-use change given the lack of reliable data. The tropics are especially important considering the high deforestation rates, the huge belowground carbon pool and the fast soil carbon turnover rates. In the framework of a pan-tropic (Peru, Cameroon and Indonesia) land-use change study, some highly relevant recommendations on the SOC stocks sampling approaches have emerged. In this study, where we focused on deeply weathered mineral soils, we quantified changes in SOC stock following land-use change (deforestation and subsequent establishment of other land-uses). We used a space-for-time substitution sampling approach, measured SOC stocks in the top three meters of soil and compared recently converted land-uses with adjacent reference forest plots. In each respective region we investigated the most predominant land-use trajectories. In total 157 plots were established across the three countries, where soil samples were taken to a depth of three meters from a central soil pit and from the topsoil (to 0.5m) from 12 pooled composite samples. Finding 1 - soil depth: despite the fact that the majority of SOC stock from the three meter profile is found below one meter depth (50 to 60 percent of total SOC stock), the significant changes in SOC were only measured in the top meter of soil, while the subsoil carbon stock remained relatively unchanged by the land-use conversion. The only exception was for older (>50 yrs) cacao plantations in Cameroon where significant decreases were found below one meter. Finding 2 - pooled composite samples taken across the plot provided more spatially representative estimates of SOC stocks than samples taken from the central soil pit.

  1. Hydrologic, water-quality, and biological assessment of Laguna de las Salinas, Ponce, Puerto Rico, January 2003-September 2004

    USGS Publications Warehouse

    Soler-López, Luis R.; Gómez-Gómez, Fernando; Rodríguez-Martínez, Jesús

    2005-01-01

    The Laguna de Las Salinas is a shallow, 35-hectare, hypersaline lagoon (depth less than 1 meter) in the municipio of Ponce, located on the southern coastal plain of Puerto Rico. Hydrologic, water-quality, and biological data in the lagoon were collected between January 2003 and September 2004 to establish baseline conditions. During the study period, rainfall was about 1,130 millimeters, with much of the rain recorded during three distinct intense events. The lagoon is connected to the sea by a shallow, narrow channel. Subtle tidal changes, combined with low rainfall and high evaporation rates, kept the lagoon at salinities above that of the sea throughout most of the study. Water-quality properties measured on-site (temperature, pH, dissolved oxygen, specific conductance, and Secchi disk transparency) exhibited temporal rather than spatial variations and distribution. Although all physical parameters were in compliance with current regulatory standards for Puerto Rico, hyperthermic and hypoxic conditions were recorded during isolated occasions. Nutrient concentrations were relatively low and in compliance with current regulatory standards (less than 5.0 and 1.0 milligrams per liter for total nitrogen and total phosphorus, respectively). The average total nitrogen concentration was 1.9 milligrams per liter and the average total phosphorus concentration was 0.4 milligram per liter. Total organic carbon concentrations ranged from 12.0 to 19.0 milligrams per liter. Chlorophyll a was the predominant form of photosynthetic pigment in the water. The average chlorophyll a concentration was 13.4 micrograms per liter. Chlorophyll b was detected (detection limits 0.10 microgram per liter) only twice during the study. About 90 percent of the primary productivity in the Laguna de Las Salinas was generated by periphyton such as algal mats and macrophytes such as seagrasses. Of the average net productivity of 13.6 grams of oxygen per cubic meter per day derived from the diel study, the periphyton and macrophyes produced 12.3 grams per cubic meter per day; about 1.3 grams (about 10 percent) were produced by the phytoplankton (plant and algae component of plankton). The total respiration rate was 59.2 grams of oxygen per cubic meter per day. The respiration rate ascribed to the plankton (all organisms floating through the water column) averaged about 6.2 grams of oxygen per cubic meter per day (about 10 percent), whereas the respiration rate by all other organisms averaged 53.0 grams of oxygen per cubic meter per day (about 90 percent). Plankton gross productivity was 7.5 grams per cubic meter per day; the gross productivity of the entire community averaged 72.8 grams per cubic meter per day. Fecal coliform bacteria counts were generally less than 200 colonies per 100 milliliters; the highest concentration was 600 colonies per 100 milliliters.

  2. Extended range radiation dose-rate monitor

    DOEpatents

    Valentine, Kenneth H.

    1988-01-01

    An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.

  3. AAPM/RSNA physics tutorial for residents: physics of flat-panel fluoroscopy systems: Survey of modern fluoroscopy imaging: flat-panel detectors versus image intensifiers and more.

    PubMed

    Nickoloff, Edward Lee

    2011-01-01

    This article reviews the design and operation of both flat-panel detector (FPD) and image intensifier fluoroscopy systems. The different components of each imaging chain and their functions are explained and compared. FPD systems have multiple advantages such as a smaller size, extended dynamic range, no spatial distortion, and greater stability. However, FPD systems typically have the same spatial resolution for all fields of view (FOVs) and are prone to ghosting. Image intensifier systems have better spatial resolution with the use of smaller FOVs (magnification modes) and tend to be less expensive. However, the spatial resolution of image intensifier systems is limited by the television system to which they are coupled. Moreover, image intensifier systems are degraded by glare, vignetting, spatial distortions, and defocusing effects. FPD systems do not have these problems. Some recent innovations to fluoroscopy systems include automated filtration, pulsed fluoroscopy, automatic positioning, dose-area product meters, and improved automatic dose rate control programs. Operator-selectable features may affect both the patient radiation dose and image quality; these selectable features include dose level setting, the FOV employed, fluoroscopic pulse rates, geometric factors, display software settings, and methods to reduce the imaging time. © RSNA, 2011.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Shaughnessy, Eric; Ardani, Kristen; Cutler, Dylan

    Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domesticmore » water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.« less

  5. Solar Plus: A Holistic Approach to Distributed Solar PV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    OShaughnessy, Eric J.; Ardani, Kristen B.; Cutler, Dylan S.

    Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domesticmore » water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.« less

  6. Multiphase flowmeter successfully measures three-phase flow at extremely high gas-volume fractions -- Gulf of Suez, Egypt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, R.B.; Borling, D.C.; Powers, B.S.

    1998-02-01

    A multiphase flowmeter (MPFM) installed in offshore Egypt has accurately measured three-phase flow in extremely gassy flow conditions. The meter is completely nonintrusive, with no moving parts, requires no flow mixing before measurement, and has no bypass loop to remove gas before multiphase measurement. Flow regimes observed during the field test of this meter ranged from severe slugging to annular flow caused by the dynamics of gas-lift gas in the production stream. Average gas-volume fraction ranged from 93 to 98% during tests conducted on seven wells. The meter was installed in the Gulf of Suez on a well protector platformmore » in the Gulf of Suez Petroleum Co. (Gupco) October field, and was placed in series with a test separator located on a nearby production platform. Wells were individually tested with flow conditions ranging from 1,300 to 4,700 B/D fluid, 2.4 to 3.9 MMscf/D of gas, and water cuts from 1 to 52%. The meter is capable of measuring water cuts up to 100%. Production was routed through both the MPFM and the test separator simultaneously as wells flowed with the assistance of gas-lift gas. The MPFM measured gas and liquid rates to within {+-} 10% of test-separator reference measurement flow rates, and accomplished this at gas-volume fractions from 93 to 96%. At higher gas-volume fractions up to 98%, accuracy deteriorated but the meter continued to provide repeatable results.« less

  7. Accuracy of the Velotron ergometer and SRM power meter.

    PubMed

    Abbiss, C R; Quod, M J; Levin, G; Martin, D T; Laursen, P B

    2009-02-01

    The purpose of this study was to determine the accuracy of the Velotron cycle ergometer and the SRM power meter using a dynamic calibration rig over a range of exercise protocols commonly applied in laboratory settings. These trials included two sustained constant power trials (250 W and 414 W), two incremental power trials and three high-intensity interval power trials. To further compare the two systems, 15 subjects performed three dynamic 30 km performance time trials. The Velotron and SRM displayed accurate measurements of power during both constant power trials (<1% error). However, during high-intensity interval trials the Velotron and SRM were found to be less accurate (3.0%, CI=1.6-4.5% and -2.6%, CI=-3.2--2.0% error, respectively). During the dynamic 30 km time trials, power measured by the Velotron was 3.7+/-1.9% (CI=2.9-4.8%) greater than that measured by the SRM. In conclusion, the accuracy of the Velotron cycle ergometer and the SRM power meter appears to be dependent on the type of test being performed. Furthermore, as each power monitoring system measures power at various positions (i.e. bottom bracket vs. rear wheel), caution should be taken when comparing power across the two systems, particularly when power is variable.

  8. 46 CFR 175.600 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Vessels Under 61 Meters (200 feet) in Length, 1983 (“ABS Steel Vessel Rules (Meters)”) 177.300. Rules..., Standard Practice for Operating Salt Spray (Fog) Apparatus (“ASTM B 117”) 175.400. ASTM B 122/B 122M-95... (“ASTM D 93”) 175.400. ASTM D 635-97, Standard test Method for Rate of Burning and or Extent and Time of...

  9. 76 FR 56433 - Loveland Area Projects-Western Area Colorado Missouri Balancing Authority-Rate Order No. WAPA-155

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-13

    ... settled (minimum 4 MW) of metered load settled using WACM hourly pricing with no using WACM hourly pricing... than 7.5% (minimum pricing in no-penalty band. Customer 10 MW) of metered load settled using imbalance... or equal to 0.5 percent of its hourly average load, no Regulation Service charges will be assessed by...

  10. Sedimentation History of Lago Guayabal, Puerto Rico, 1913-2001

    USGS Publications Warehouse

    Soler-López, Luis R.

    2003-01-01

    The Lago Guayabal dam, located in the municipality of Villalba in southern Puerto Rico, was constructed in 1913 for irrigation of croplands in the southern coastal plains and is owned and operated by the Puerto Rico Electric Power Authority. The reservoir had an original storage capacity of 11.82 million cubic meters and a drainage area upstream of the dam of 112 square kilometers. Sedimentation has reduced the storage capacity to 6.12 million cubic meters in 2001, which represents a storage loss of about 48 percent. However, the actual sediment accumulation in the reservoir during the 88 years is greater, because some sediment removal was conducted between 1940 and 1948 by dredging and sluicing. This report summarizes the historical data from a 1913 land survey and eight bathymetric surveys conducted between 1914 and 2001, and the relation of high sedimentation to agricultural land practices within the Lago Guayabal basin and six major hurricanes which made landfall on the island. The reservoir had an area-normalized sedimentation rate of about 1,863 cubic meters per square kilometer per year between 1913 and 1936 from a 112 square kilometer basin. In 1972, a new dam upstream along the Rio Toa Vaca impounded runoff from 57.5 square kilometers, and sediment transport to Lago Guayabal was reduced. A comparison of bathymetric survey results between 1972 and 2001 indicates an area-normalized sedimentation rate of 1,120 cubic meters per square kilometer per year or about 60 percent of the rate between 1913 and 1936. The significant reduction (almost half) of the sedimentation rate after the Toa Vaca dam was built may indicate that erosion susceptibility of the Rio Toa Vaca watershed is about twice that of the Rio Jacaguas watershed impounded by Lago Guayabal.

  11. Effects of erosion control structures along a portion of the northern Chesapeake Bay shoreline

    USGS Publications Warehouse

    Zabawa, C.F.; Kerhin, R.T.; Bayley, S.

    1981-01-01

    A 6.500-meter reach of western Chesapeake Bay shoreline (lower Mayo Peninsula) lost about 1.1??106 cubic meters of sediment (equivalent to 170 cubic meters lost per meter of shoreline) between 1846 and 1932, when the first aerial photographs show the shoreline already substantially protected by a system of groins and intermittent bulkheading. These structures have eliminated the fastland as a source of erodable material, and have starved the supply of sand for littoral drift, thus limiting the extent of the beaches to the remaining groin fields. Volumes of sediment involved in these impacts are small in the overall sediment budget. Bulkheads produce no deficit in the budget since scouring of the beaches on their seaward sides makes up for the decreased erosion of protected fastland. Groins trap little of the potential littoral drift (computed to be about 104 cubic meters per meter of shoreline per year). The sand supply in the remaining beaches is nearly equivalent to the annual loss of sediment from the entire shoreline system due to the long-term rate of erosion of the shoreline and nearshore between 1846 and 1932. ?? 1981 Springer-Verlag New York Inc.

  12. HOT WATER DRILL FOR TEMPERATE ICE.

    USGS Publications Warehouse

    Taylor, Philip L.

    1984-01-01

    The development of a high-pressure hot-water drill is described, which has been used reliably in temperate ice to depths of 400 meters with an average drill rate of about 1. 5 meters per minute. One arrangement of the equipment weighs about 500 kilograms, and can be contained on two sleds, each about 3 meters long. Simplified performance equations are given, and experiments with nozzle design suggest a characteristic number describing the efficiency of each design, and a minimum bore-hole diameter very close to 6 centimeters for a hot water drill. Also discussed is field experience with cold weather, water supply, and contact with englacial cavities and the glacier bed.

  13. Optical clocks and relativity.

    PubMed

    Chou, C W; Hume, D B; Rosenband, T; Wineland, D J

    2010-09-24

    Observers in relative motion or at different gravitational potentials measure disparate clock rates. These predictions of relativity have previously been observed with atomic clocks at high velocities and with large changes in elevation. We observed time dilation from relative speeds of less than 10 meters per second by comparing two optical atomic clocks connected by a 75-meter length of optical fiber. We can now also detect time dilation due to a change in height near Earth's surface of less than 1 meter. This technique may be extended to the field of geodesy, with applications in geophysics and hydrology as well as in space-based tests of fundamental physics.

  14. Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive

    NASA Technical Reports Server (NTRS)

    Evans, Kurt B.

    1989-01-01

    Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.

  15. Historical and hypothetical future sedimentation and water storage in Kajakai Reservoir, central Afghanistan

    USGS Publications Warehouse

    Vining, Kevin C.; Vecchia, Aldo V.

    2008-01-01

    Sedimentation has reduced water storage in Kajakai Reservoir. If current sedimentation rates continue, hypothetical future reservoir water volumes at the spillway elevation of 1,033.5 meters could be reduced about 22 percent from 2006 to 2057. Even if the spillway elevation is raised to 1,045 meters, a severe drought could result in large multiyear irrigation-supply deficits in which reservoir water levels remain below 1,022 meters for more than 4 years. Hypothetical climate change and sedimentation could result in greater water-supply deficits. The chance of having sufficient water supplies in Kajakai Reservoir during the worst month is about 47 percent.

  16. Twentieth century arroyo changes in Chaco Culture National Historical Park

    USGS Publications Warehouse

    Gellis, Allen C.

    2002-01-01

    Chaco Wash arroyo channel changes in the 20th century have become a major concern of the National Park Service. Several archeologic and cultural sites are located in the Chaco Wash corridor; thus, increased erosional activity of Chaco Wash, such as channel incision and increased meandering, may affect these sites. Through field surveys, photogrammetric analyses, and reviews of existing reports and maps, arroyo changes at Chaco Culture National Historic Park were documented. Arroyo changes were documented for the inner active channel and the entire arroyo cross section. The inner channel of Chaco Wash evolved from a wide, braided channel in the 1930's to a narrower channel with a well-developed flood plain by the 1970's. From 1934 to 1973 the active channel narrowed an average of 26 meters, and from the 1970's to 2000 the channel narrowed an average of 9 meters. Overall from 1934 to 2000, the inner channel narrowed an average of 30 meters. From 1934 to 2000, the top of Chaco Wash widened at four cross sections, narrowed at one, and remained the same at another. The top of Chaco Wash widened at a rate of 0.4 meter per year from the 1970's to 2000 compared with 0.2 meter per year from 1934 to 1973. At 50-percent depth or halfway down the arroyo channel, four cross sections widened and two cross sections narrowed from 1934 to 2000. Rates of widening at 50-percent depth decreased from 0.2 meter per year from 1934 to 1973 to 0.1 meter per year from the 1970's to 2000. From 1934 to 2000, arroyo depth decreased at five of six cross sections and increased at one cross section. Arroyo depth between 1934 and 1973 decreased an average 1.4 meters from aggradation and between the 1970's and 2000 increased an average 0.4 meter from channel scour. From 1934 to 2000, arroyo cross-sectional area decreased at all six cross sections. Cross-sectional areas in Chaco Wash decreased from 1934 to 1973 as a result of sediment deposition and both decreased and increased from the 1970's to 2000. The cross-sectional area decreased by the 1970's due to channel narrowing and flood-plain formation. Increases in cross-sectional area are from channel scour and channel widening. Photogrammetric analyses of volumetric changes for a 1.7-kilometer reach of Chaco Wash showed sediment deposition from 1934 to 1973 of 64 square meters per unit length of channel over 1.7 kilometers to erosion from 1973 to 2000 of 7 square meters per unit length of channel. Chaco Wash evolved from a braided channel in the 1930's to a narrow, sinuous inner channel by the 1970's. Chaco Wash was widening in the 1930's, leading to sediment deposition and formation of an inner flood plain. Channel narrowing resulted from increased sediment deposition on the flood plain. Sediment deposition may be related to a decrease in peak flows, an increase in flood-plain vegetation, or an increase in the transport of fine-grained sediment. Increases in bankfull depth of Chaco Wash between the 1970's and 2000 were due to aggradation of the flood plain and channel scour. Thus, rates of aggradation and cross-sectional filling were greater from 1934 to the 1970's than from the 1970's to 2000.

  17. Timing considerations of Helmet Mounted Display performance

    NASA Technical Reports Server (NTRS)

    Tharp, Gregory; Liu, Andrew; French, Lloyd; Lai, Steve; Stark, Lawrence

    1992-01-01

    The Helmet Mounted Display (HMD) system developed in our lab should be a useful teleoperator systems display if it increases operator performance of the desired task; it can, however, introduce degradation in performance due to display update rate constraints and communication delays. Display update rates are slowed by communication bandwidth and/or computational power limitations. We used simulated 3D tracking and pick-and-place tasks to characterize performance levels for a range of update rates. Initial experiments with 3D tracking indicate that performance levels plateau at an update rate between 10 and 20 Hz. We have found that using the HMD with delay decreases performance as delay increases.

  18. A portable hypergolic oxidizer vapor sensor for NASA's Space Shuttle program

    NASA Technical Reports Server (NTRS)

    Helms, W. R.

    1978-01-01

    The design and performance characteristics of an electrochemical NO2 sensor selected by NASA for the space shuttle program is described. The instrument consists of a sample pump, an electrochemical cell, and control and display electronics. The pump pushes the sample through the electrochemical cell where the vapors are analyzed and an output proportional to the NO2 concentration is produced. The output is displayed on a panel meter, and is also available at a recorder jack. The electrochemical cell is made up of a polypropylene chamber covered with teflon membrane faceplates. Plantinum electrodes are bonded to the faceplates, and the sensing and counter electrodes are potentiostatically controlled at -200 mV with respect to the reference electrode. The cell is filled with electrolyte, consisting of 13.5 cc of 23% solution of KOH.

  19. Does Mckuer's Law Hold for Heart Rate Control via Biofeedback Display?

    NASA Technical Reports Server (NTRS)

    Courter, B. J.; Jex, H. R.

    1984-01-01

    Some persons can control their pulse rate with the aid of a biofeedback display. If the biofeedback display is modified to show the error between a command pulse-rate and the measured rate, a compensatory (error correcting) heart rate tracking control loop can be created. The dynamic response characteristics of this control loop when subjected to step and quasi-random disturbances were measured. The control loop includes a beat-to-beat cardiotachmeter differenced with a forcing function from a quasi-random input generator; the resulting error pulse-rate is displayed as feedback. The subject acts to null the displayed pulse-rate error, thereby closing a compensatory control loop. McRuer's Law should hold for this case. A few subjects already skilled in voluntary pulse-rate control were tested for heart-rate control response. Control-law properties are derived, such as: crossover frequency, stability margins, and closed-loop bandwidth. These are evaluated for a range of forcing functions and for step as well as random disturbances.

  20. Bimanual tapping of a syncopated rhythm reveals hemispheric preferences for relative movement frequencies.

    PubMed

    Pflug, Anja; Gompf, Florian; Kell, Christian Alexander

    2017-08-01

    In bimanual multifrequency tapping, right-handers commonly use the right hand to tap the relatively higher rate and the left hand to tap the relatively lower rate. This could be due to hemispheric specializations for the processing of relative frequencies. An extension of the double-filtering-by-frequency theory to motor control proposes a left hemispheric specialization for the control of relatively high and a right hemispheric specialization for the control of relatively low tapping rates. We investigated timing variability and rhythmic accentuation in right handers tapping mono- and multifrequent bimanual rhythms to test the predictions of the double-filtering-by-frequency theory. Yet, hemispheric specializations for the processing of relative tapping rates could be masked by a left hemispheric dominance for the control of known sequences. Tapping was thus either performed in an overlearned quadruple meter (tap of the slow rhythm on the first auditory beat) or in a syncopated quadruple meter (tap of the slow rhythm on the fourth auditory beat). Independent of syncopation, the right hand outperformed the left hand in timing accuracy for fast tapping. A left hand timing benefit for slow tapping rates as predicted by the double-filtering-by-frequency theory was only found in the syncopated tapping group. This suggests a right hemisphere preference for the control of slow tapping rates when rhythms are not overlearned. Error rates indicate that overlearned rhythms represent hierarchically structured meters that are controlled by a single timer that could potentially reside in the left hemisphere. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Detection of smoldering combustion of coal with an odor meter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, J.C.

    1995-05-01

    A commercially available odor meter was evaluated as a detector of smoldering coal combustion, and compared with incipient carbon monoxide (CO) and hydrogen sulfide (H{sub 2}S) detection and a commercially available ionization-type smoke detector. Ten smoldering coal combustion experiments were conducted. For eight of the experiments, Pittsburgh seam coal with an average particle diameter of approximately 5 cm was heated by embedded electrical strip heaters. For two of the experiments mine size Pittsburgh seam coal was heated. Heating rates of 0.5, 0.8, and 1.1. kw were selected to provide experimental conditions characteristic of very slow and moderately fast heating formore » coal sample mass between 3 and 10 kg. It was found that the odor meter and smoke detector alarm had a good correlation, with the odor meter alarm occurring prior to the smoke alarm in four of the ten experiments. The odor meter gave an increase in its output signal above ambient equivalent to detecting 1 ppm of H{sub 2}S (ten times the odor threshold of H{sub 2}S) as an alarm value. This observed odor meter response occurred prior to the electrochemical detection of H{sub 2}S for five of the six experiments for which it was evaluated. In all six experiments for which the smoke optical density was evaluated, it was less than 0.023 m{sup -1} prior to the odor meter reaching alarm. In each of the eight experiments with 5 cm diameter coal particles the CO exceeded 5 ppm at odor meter alarm, while for the two experiments with mine size coal the CO was less than 3 ppm at odor meter alarm. The odor meter, as tested, is not a significant improvement over smoke and CO detectors. Because the odor meter responds to a variety of chemical compounds, with suitable modification and increased sensitivity it may be useful for detection of mine fires and thereby enhance mine safety.« less

  2. The network adjustment aimed for the campaigned gravity survey using a Bayesian approach: methodology and model test

    NASA Astrophysics Data System (ADS)

    Chen, Shi; Liao, Xu; Ma, Hongsheng; Zhou, Longquan; Wang, Xingzhou; Zhuang, Jiancang

    2017-04-01

    The relative gravimeter, which generally uses zero-length springs as the gravity senor, is still as the first choice in the field of terrestrial gravity measurement because of its efficiency and low-cost. Because the drift rate of instrument can be changed with the time and meter, it is necessary for estimating the drift rate to back to the base or known gravity value stations for repeated measurement at regular hour's interval during the practical survey. However, the campaigned gravity survey for the large-scale region, which the distance of stations is far away from serval or tens kilometers, the frequent back to close measurement will highly reduce the gravity survey efficiency and extremely time-consuming. In this paper, we proposed a new gravity data adjustment method for estimating the meter drift by means of Bayesian statistical interference. In our approach, we assumed the change of drift rate is a smooth function depend on the time-lapse. The trade-off parameters were be used to control the fitting residuals. We employed the Akaike's Bayesian Information Criterion (ABIC) for the estimated these trade-off parameters. The comparison and analysis of simulated data between the classical and Bayesian adjustment show that our method is robust and has self-adaptive ability for facing to the unregularly non-linear meter drift. At last, we used this novel approach to process the realistic campaigned gravity data at the North China. Our adjustment method is suitable to recover the time-varied drift rate function of each meter, and also to detect the meter abnormal drift during the gravity survey. We also defined an alternative error estimation for the inversed gravity value at the each station on the basis of the marginal distribution theory. Acknowledgment: This research is supported by Science Foundation Institute of Geophysics, CEA from the Ministry of Science and Technology of China (Nos. DQJB16A05; DQJB16B07), China National Special Fund for Earthquake Scientific Research in Public Interest (Nos. 201508006; 201508009).

  3. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kearny, C.H.

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy ofmore » {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these instructions, the builder can verify the insulating ability of his materials by checking the leakage rate and comparing it to the author's leakage tests.« less

  4. Re-usable electrochemical glucose sensors integrated into a smartphone platform.

    PubMed

    Bandodkar, Amay J; Imani, Somayeh; Nuñez-Flores, Rogelio; Kumar, Rajan; Wang, Chiyi; Mohan, A M Vinu; Wang, Joseph; Mercier, Patrick P

    2018-03-15

    This article demonstrates a new smartphone-based reusable glucose meter. The glucose meter includes a custom-built smartphone case that houses a permanent bare sensor strip, a stylus that is loaded with enzyme-carbon composite pellets, and sensor instrumentation circuits. A custom-designed Android-based software application was developed to enable easy and clear display of measured glucose concentration. A typical test involves the user loading the software, using the stylus to dispense an enzymatic pellet on top of the bare sensor strip affixed to the case, and then introducing the sample. The electronic module then acquires and wirelessly transmits the data to the application software to be displayed on the screen. The deployed pellet is then discarded to regain the fresh bare sensor surface. Such a unique working principle allows the system to overcome challenges faced by previously reported reusable sensors, such as enzyme degradation, leaching, and hysteresis effects. Studies reveal that the enzyme loaded in the pellets are stable for up to 8 months at ambient conditions, and generate reproducible sensor signals. The work illustrates the significance of the pellet-based sensing system towards realizing a reusable, point-of-care sensor that snugly fits around a smartphone and which does not face issues usually common to reusable sensors. The versatility of this system allows it to be easily modified to detect other analytes for application in a wide range of healthcare, environmental and defense domains. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Spectral and Polarimetric Imagery Collection Experiment

    DTIC Science & Technology

    2011-12-01

    Also melted snow liquid rate Optical rain gauge Rain rate Possibly snow rate Visibility meter Visibility Smoke, fog, haze Pyranometer Sun and sky...performance of the IR imagery due to thermal effect or possible inversion layer effects. Pyranometers measure total sun and sky radiation. If the direction

  6. Portable wastewater flow meter

    DOEpatents

    Hunter, Robert M.

    1999-02-02

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  7. Portable wastewater flow meter

    DOEpatents

    Hunter, Robert M.

    1990-01-01

    A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

  8. Economic Analysis and Optimal Sizing for behind-the-meter Battery Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Di; Kintner-Meyer, Michael CW; Yang, Tao

    This paper proposes methods to estimate the potential benefits and determine the optimal energy and power capacity for behind-the-meter BSS. In the proposed method, a linear programming is first formulated only using typical load profiles, energy/demand charge rates, and a set of battery parameters to determine the maximum saving in electric energy cost. The optimization formulation is then adapted to include battery cost as a function of its power and energy capacity in order to capture the trade-off between benefits and cost, and therefore to determine the most economic battery size. Using the proposed methods, economic analysis and optimal sizingmore » have been performed for a few commercial buildings and utility rate structures that are representative of those found in the various regions of the Continental United States. The key factors that affect the economic benefits and optimal size have been identified. The proposed methods and case study results cannot only help commercial and industrial customers or battery vendors to evaluate and size the storage system for behind-the-meter application, but can also assist utilities and policy makers to design electricity rate or subsidies to promote the development of energy storage.« less

  9. Measurement of submarine groundwater discharge using diverse methods in Coleroon Estuary, Tamil Nadu, India

    NASA Astrophysics Data System (ADS)

    Prakash, R.; Srinivasamoorthy, K.; Gopinath, S.; Saravanan, K.

    2018-03-01

    Submarine groundwater discharge (SGD) is described as submarine inflow of fresh and brackish groundwater from land into the sea. The release of sewages from point and non-point source pollutants from industries, agricultural and domestic activities gets discharged through groundwater to ocean creating natural disparity like decreasing flora fauna and phytoplankton blooms. Hence, to quantify fluxes of SGD in coastal regions is important. Quantification of SGD was attempted in Coleroon estuary, India, using three dissimilar methods like water budget, Darcy law and manual seepage meter. Three seepage meters were installed at two prominent litho units (alluvium and fluvio marine) at a distance of (0-14.7 km) away from Bay of Bengal. The water budget and Darcy law-quantified submarine seepage at a rate of 6.9 × 106 and 3.2 × 103 to 308.3 × 103 m3 year-1, respectively, and the seepage meter quantified seepage rate of 0.7024 m h-1 at an average. Larger seepage variations were isolated from three different techniques and the seepage rates were found to be influenced by hydrogeological characteristics of the litho units and distance from the coast.

  10. A High-Pressure Bi-Directional Cycloid Rotor Flowmeter

    PubMed Central

    Liu, Shuo; Ding, Fan; Ding, Chuan; Man, Zaipeng

    2014-01-01

    The measurement of the flow rate of various liquids and gases is critical in industrial automation. Rotary positive displacement meters (rotary PD meters) are highly accurate flowmeters that are widely employed in engineering applications, especially in custody transfer operations and hydraulic control systems. This paper presents a high pressure rotary PD meter containing a pair of internal cycloid rotors. It has the advantages of concise structure, low pressure loss, high accuracy and low noise. The curve of the internal rotor is designed as an equidistant curtate epicycloid curve with the external rotor curve as its conjugate. The calculation method used to determine the displacement of the cycloid rotor flowmeter is discussed. A prototype was fabricated, and experiments were performed to confirm measurements over a flow range of 1–100 L/min with relative errors of less than ±0.5%. The pressure loss through the flowmeter was about 3 bar at a flow rate of 100 L/min. PMID:25196162

  11. Sedimentation survey of Lago Lucchetti, Yauco, Puerto Rico, September 2013–May 2014

    USGS Publications Warehouse

    Gómez-Fragoso, Julieta

    2016-08-23

    The U.S. Geological Survey conducted a sedimentation survey of Lago Lucchetti, Yauco, Puerto Rico, in 2013–14 in cooperation with the Puerto Rico Aqueduct and Sewer Authority. The survey updated a previous survey, conducted in 2000, and provided accurate information regarding reservoir storage capacity and sedimen­tation rate using bathymetric techniques and a global positioning system coupled with a depth sounder device. The results of the 2013–14 survey indicated a total storage capacity for Lago Lucchetti of 10.21 million cubic meters and a long­-term sedimentation rate loss of 0.16 million cubic meters per year based on the original capacity in 1952. Sediment accumulation was about 10.14 million cubic meters over the life of the reservoir, which represents a storage decrease of about 50 percent of the original capacity in 1952. On the basis of a comparison between the 2013–14 and 2000 surveys, the useful life for Lago Lucchetti is projected to end in 2076.

  12. iPhysioMeter: a new approach for measuring heart rate and normalized pulse volume using only a smartphone.

    PubMed

    Matsumura, Kenta; Yamakoshi, Takehiro

    2013-12-01

    Heart rate (HR) and normalized pulse volume (NPV) are physiological indices that have been used in a diversity of psychological studies. However, measuring these indices often requires laborious processes. We therefore developed a new smartphone program, named iPhysioMeter, that makes it possible to measure beat-by-beat HR and ln NPV using only a smartphone. We examined its accuracy against conventional laboratory measures. Mental stress tasks were used to alter HR and ln NPV in 12 participants. Bland-Altman analyses revealed negligible proportional bias for HR and ln NPV or for their change values, expressed as ΔHR and Δln NPV. However, a relatively large fixed bias did emerge for ln NPV, as well as a small one for Δln NPV, although both were within the limits of agreement. These findings suggest that iPhysioMeter can yield valid measures of the absolute level of HR and of relative changes in ln NPV.

  13. Formulation and Development of Metered Dose Inhalations of Salbutamol in Solution Form

    PubMed Central

    Khale, Anubha; Bajaj, Amrita

    2011-01-01

    In the present study attempts were made to prepare metered dose inhalation of salbutamol in solution form and compared it with the marketed metered dose inhalation in suspension form. Solution form of the drug was found better than marketed suspension formulation with respect to homogeneity and content uniformity. Propellant blend P-11 and P-12 in the proportion 30:70 was selected as it gave optimum vapour pressure. Surfactant oleic acid in concentration 10 mg per can was selected as it gave best results with clarity, spray pattern, vapour pressure, content per spray and rate of evaporation. Ethyl alcohol 2 ml per can was used as a cosolvent to give a clear solution, optimum vapour pressure, maximum content per spray and fair rate of evaporation. The selected formulation was subjected to the physico-chemical evaluation tests as per the standard pharmacopoeial procedures and the characteristics of the formulations were further compared with a conventional marketed formulation. In vitro study reveled the net respirable fraction was better than marketed preparation. PMID:22923867

  14. Liquid fuel injection elements for rocket engines

    NASA Technical Reports Server (NTRS)

    Cox, George B., Jr. (Inventor)

    1993-01-01

    Thrust chambers for liquid propellant rocket engines include three principal components. One of these components is an injector which contains a plurality of injection elements to meter the flow of propellants at a predetermined rate, and fuel to oxidizer mixture ratio, to introduce the mixture into the combustion chamber, and to cause them to be atomized within the combustion chamber so that even combustion takes place. Evolving from these injectors are tube injectors. These tube injectors have injection elements for injecting the oxidizer into the combustion chamber. The oxidizer and fuel must be metered at predetermined rates and mixture ratios in order to mix them within the combustion chamber so that combustion takes place smoothly and completely. Hence tube injectors are subject to improvement. An injection element for a liquid propellant rocket engine of the bipropellant type is provided which includes tangential fuel metering orifices, and a plurality of oxidizer tube injection elements whose injection tubes are also provided with tangential oxidizer entry slots and internal reed valves.

  15. Use of flumes in metering discharge at gaging stations

    USGS Publications Warehouse

    Kilpatrick, F.A.; Schneider, V.R.

    1982-01-01

    Flumes for metering discharge are usually of two general types--critical-flow flumes and supercritical-flow flumes. In this report the principles underlying the design of each are discussed, the most commonly used flumes of each of the two types are described, and discharge ratings for each are presented. Considerations in choosing and fitting the appropriate flume for a given situation are discussed along with construction techniques and operational experiences.

  16. Satellite image maps of Pakistan

    USGS Publications Warehouse

    ,

    1997-01-01

    Georeferenced Landsat satellite image maps of Pakistan are now being made available for purchase from the U.S. Geological Survey (USGS). The first maps to be released are a series of Multi-Spectral Scanner (MSS) color image maps compiled from Landsat scenes taken before 1979. The Pakistan image maps were originally developed by USGS as an aid for geologic and general terrain mapping in support of the Coal Resource Exploration and Development Program in Pakistan (COALREAP). COALREAP, a cooperative program between the USGS, the United States Agency for International Development, and the Geological Survey of Pakistan, was in effect from 1985 through 1994. The Pakistan MSS image maps (bands 1, 2, and 4) are available as a full-country mosaic of 72 Landsat scenes at a scale of 1:2,000,000, and in 7 regional sheets covering various portions of the entire country at a scale of 1:500,000. The scenes used to compile the maps were selected from imagery available at the Eros Data Center (EDC), Sioux Falls, S. Dak. Where possible, preference was given to cloud-free and snow-free scenes that displayed similar stages of seasonal vegetation development. The data for the MSS scenes were resampled from the original 80-meter resolution to 50-meter picture elements (pixels) and digitally transformed to a geometrically corrected Lambert conformal conic projection. The cubic convolution algorithm was used during rotation and resampling. The 50-meter pixel size allows for such data to be imaged at a scale of 1:250,000 without degradation; for cost and convenience considerations, however, the maps were printed at 1:500,000 scale. The seven regional sheets have been named according to the main province or area covered. The 50-meter data were averaged to 150-meter pixels to generate the country image on a single sheet at 1:2,000,000 scale

  17. Environmental effects of large impacts on Mars.

    PubMed

    Segura, Teresa L; Toon, Owen B; Colaprete, Anthony; Zahnle, Kevin

    2002-12-06

    The martian valley networks formed near the end of the period of heavy bombardment of the inner solar system, about 3.5 billion years ago. The largest impacts produced global blankets of very hot ejecta, ranging in thickness from meters to hundreds of meters. Our simulations indicated that the ejecta warmed the surface, keeping it above the freezing point of water for periods ranging from decades to millennia, depending on impactor size, and caused shallow subsurface or polar ice to evaporate or melt. Large impacts also injected steam into the atmosphere from the craters or from water innate to the impactors. From all sources, a typical 100-, 200-, or 250-kilometers asteroid injected about 2, 9, or 16 meters, respectively, of precipitable water into the atmosphere, which eventually rained out at a rate of about 2 meters per year. The rains from a large impact formed rivers and contributed to recharging aquifers.

  18. Gravimetric geodesy and sea surface topography studies by means of satellite-to-satellite tracking and satellite altimetry

    NASA Technical Reports Server (NTRS)

    Siry, J. W.

    1972-01-01

    A satellite-to-satellite tracking experiment is planned between ATS-F and GEOS-C with a range accuracy of 2-meters and a range rate accuracy of 0.035 centimeters per second for a 10-second integration time. This experiment is planned for 1974. It is anticipated that it will improve the spatial resolution of the satellite geoid by half an order of magnitude to about 6 degrees. Longer integration times should also permit a modest increase in the acceleration resolution. Satellite altimeter data will also be obtained by means of GEOS-C. An overall accuracy of 5-meters in altitude is the goal. The altimeter, per se, is expected to have an instrumental precision of about 2 meters, and an additional capability to observe with a precision of about 0.2 meters for limited periods.

  19. 40 CFR 1065.545 - Validation of proportional flow control for batch sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the estimate, SEE, of the sample flow rate versus the total flow rate. For each test interval, demonstrate that SEE was less than or equal to 3.5% of the mean sample flow rate. (b) For any pair of flow meters, use recorded sample and total flow rates, where total flow rate means the raw exhaust flow rate...

  20. 76 FR 59682 - Desert Southwest Customer Service Region-Western Area Lower Colorado Balancing Authority-Rate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-27

    ... percentage of metered generation, since there is no load. 2. Intermittent resources are exempt from the outer...--Western Area Lower Colorado Balancing Authority--Rate Order No. WAPA-151 AGENCY: Western Area Power... Services Formula Rates. SUMMARY: The Deputy Secretary of Energy has confirmed and approved Rate Order No...

  1. Alternative Fuels Data Center

    Science.gov Websites

    Plug-In Electric Vehicle (PEV) Charging Rate Incentive - Xcel Energy Xcel Energy offers two rate options to qualified residential customers for charging PEVs. The Electric Vehicle (EV) Rate and the Time -of-Day Plan are optional and require a separate meter. For rate information, including how to qualify

  2. An alternative arrangement of metered dosing fluid using centrifugal pump

    NASA Astrophysics Data System (ADS)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for industries in Bangladesh and have been implemented in two salt iodization plants at Narayangang.

  3. The Design and Development of Test Platform for Wheat Precision Seeding Based on Image Processing Techniques

    NASA Astrophysics Data System (ADS)

    Li, Qing; Lin, Haibo; Xiu, Yu-Feng; Wang, Ruixue; Yi, Chuijie

    The test platform of wheat precision seeding based on image processing techniques is designed to develop the wheat precision seed metering device with high efficiency and precision. Using image processing techniques, this platform gathers images of seeds (wheat) on the conveyer belt which are falling from seed metering device. Then these data are processed and analyzed to calculate the qualified rate, reseeding rate and leakage sowing rate, etc. This paper introduces the whole structure, design parameters of the platform and hardware & software of the image acquisition system were introduced, as well as the method of seed identification and seed-space measurement using image's threshold and counting the seed's center. By analyzing the experimental result, the measurement error is less than ± 1mm.

  4. Analysis Article on the Performance Analysis of the OneTouch® UltraVue™ Blood Glucose Monitoring System

    PubMed Central

    Solnica, Bogdan

    2009-01-01

    In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch® UltraVue™ blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. PMID:20144432

  5. Analysis article on the performance analysis of the OneTouch UltraVue blood glucose monitoring system.

    PubMed

    Solnica, Bogdan

    2009-09-01

    In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch UltraVue blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. 2009 Diabetes Technology Society.

  6. Possible stressors in a neonatal intensive care unit at a university hospital

    PubMed Central

    Jordão, Kamila Reis; Pinto, Lauriane de Assis Proença; Machado, Lucimer Rocha; Costa, Laetitia Braga Vasconcellos de Lima; Trajano, Eduardo Tavares Lima

    2016-01-01

    Objective To investigate possible stressors to which newborns are exposed in the neonatal intensive care unit. Methods The levels of continuous noise were checked by a decibel meter positioned near the ear of the newborn, brightness was observed by a light meter positioned in the incubator in front of the newborn's eyes, and temperature was checked through the incubator display. The evaluations were performed in three periods of the day, with ten measurements taken at one-minute intervals during each shift for the subsequent statistical analysis. Results All shifts showed noise above acceptable levels. Morning (p < 0.001), afternoon (p < 0.05) and night (p < 0.001) showed a significant increase compared to the control. The brightness significantly exceeded the normal range (p < 0.01) in the morning. We observed that only one of the incubators was within the normal temperature limits. Conclusion The noise, brightness and temperature intensities were not in accordance with regulatory standards and thus might be possible stressors to newborns. PMID:27626948

  7. PCLC flake-based apparatus and method

    DOEpatents

    Cox, Gerald P; Fromen, Cathy A; Marshall, Kenneth L; Jacobs, Stephen D

    2012-10-23

    A PCLC flake/fluid host suspension that enables dual-frequency, reverse drive reorientation and relaxation of the PCLC flakes is composed of a fluid host that is a mixture of: 94 to 99.5 wt % of a non-aqueous fluid medium having a dielectric constant value .di-elect cons., where 1<.di-elect cons.<7, a conductivity value .sigma., where 10.sup.-9>.sigma.>10.sup.-7 Siemens per meter (S/m), and a resistivity r, where 10.sup.7>r>10.sup.10 ohm-meters (.OMEGA.-m), and which is optically transparent in a selected wavelength range .DELTA..lamda.; 0.0025 to 0.25 wt % of an inorganic chloride salt; 0.0475 to 4.75 wt % water; and 0.25 to 2 wt % of an anionic surfactant; and 1 to 5 wt % of PCLC flakes suspended in the fluid host mixture. Various encapsulation forms and methods are disclosed including a Basic test cell, a Microwell, a Microcube, Direct encapsulation (I), Direct encapsulation (II), and Coacervation encapsulation. Applications to display devices are disclosed.

  8. Reduce volume of head-up display by image stitching

    NASA Astrophysics Data System (ADS)

    Chiu, Yi-Feng; Su, Guo-Dung J.

    2016-09-01

    Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.

  9. Guidelines for application of fluorescent lamps in high-performance avionic backlight systems

    NASA Astrophysics Data System (ADS)

    Syroid, Daniel D.

    1997-07-01

    Fluorescent lamps have proven to be well suited for use in high performance avionic backlight systems as demonstrated by numerous production applications for both commercial and military cockpit displays. Cockpit display applications include: Boeing 777, new 737s, F-15, F-16, F-18, F-22, C- 130, Navy P3, NASA Space Shuttle and many others. Fluorescent lamp based backlights provide high luminance, high lumen efficiency, precision chromaticity and long life for avionic active matrix liquid crystal display applications. Lamps have been produced in many sizes and shapes. Lamp diameters range from 2.6 mm to over 20 mm and lengths for the larger diameter lamps range to over one meter. Highly convoluted serpentine lamp configurations are common as are both hot and cold cathode electrode designs. This paper will review fluorescent lamp operating principles, discuss typical requirements for avionic grade lamps, compare avionic and laptop backlight designs and provide guidelines for the proper application of lamps and performance choices that must be made to attain optimum system performance considering high luminance output, system efficiency, dimming range and cost.

  10. All-CMOS night vision viewer with integrated microdisplay

    NASA Astrophysics Data System (ADS)

    Goosen, Marius E.; Venter, Petrus J.; du Plessis, Monuko; Faure, Nicolaas M.; Janse van Rensburg, Christo; Rademeyer, Pieter

    2014-02-01

    The unrivalled integration potential of CMOS has made it the dominant technology for digital integrated circuits. With the advent of visible light emission from silicon through hot carrier electroluminescence, several applications arose, all of which rely upon the advantages of mature CMOS technologies for a competitive edge in a very active and attractive market. In this paper we present a low-cost night vision viewer which employs only standard CMOS technologies. A commercial CMOS imager is utilized for near infrared image capturing with a 128x96 pixel all-CMOS microdisplay implemented to convey the image to the user. The display is implemented in a standard 0.35 μm CMOS process, with no process alterations or post processing. The display features a 25 μm pixel pitch and a 3.2 mm x 2.4 mm active area, which through magnification presents the virtual image to the user equivalent of a 19-inch display viewed from a distance of 3 meters. This work represents the first application of a CMOS microdisplay in a low-cost consumer product.

  11. MethylMeter®: bisulfite-free quantitative and sensitive DNA methylation profiling and mutation detection in FFPE samples

    PubMed Central

    McCarthy, David; Pulverer, Walter; Weinhaeusel, Andreas; Diago, Oscar R; Hogan, Daniel J; Ostertag, Derek; Hanna, Michelle M

    2016-01-01

    Aim: Development of a sensitive method for DNA methylation profiling and associated mutation detection in clinical samples. Materials & methods: Formalin-fixed and paraffin-embedded tumors received by clinical laboratories often contain insufficient DNA for analysis with bisulfite or methylation sensitive restriction enzymes-based methods. To increase sensitivity, methyl-CpG DNA capture and Coupled Abscription PCR Signaling detection were combined in a new assay, MethylMeter®. Gliomas were analyzed for MGMT methylation, glioma CpG island methylator phenotype and IDH1 R132H. Results: MethylMeter had 100% assay success rate measuring all five biomarkers in formalin-fixed and paraffin-embedded tissue. MGMT methylation results were supported by survival and mRNA expression data. Conclusion: MethylMeter is a sensitive and quantitative method for multitarget DNA methylation profiling and associated mutation detection. The MethylMeter-based GliomaSTRAT assay measures methylation of four targets and one mutation to simultaneously grade gliomas and predict their response to temozolomide. This information is clinically valuable in management of gliomas. PMID:27337298

  12. The effect of time in use on the display performance of the iPad.

    PubMed

    Caffery, Liam J; Manthey, Kenneth L; Sim, Lawrence H

    2016-07-01

    The aim of this study was to evaluate changes to the luminance, luminance uniformity and conformance to the digital imaging and communication in medicine greyscale standard display function (GSDF) as a function of time in use for the iPad. Luminance measurements of the American Association of Physicists in Medicine (AAPM) Group 18 task group (TG18) luminance uniformity and luminance test patterns (TG18-UNL and TG18-LN8) were performed using a calibrated near-range luminance meter. Nine sets of measurements were taken, where the time in use of the iPad ranged from 0 to 2500 h. The maximum luminance (Lmax) of the display decreased (367-338 cdm(-2)) as a function of time. The minimum luminance remained constant. The maximum non-uniformity coefficient was 11%. Luminance uniformity decreased slightly as a function of time in use. The conformance of the iPad deviated from the GSDF curve at commencement of use. Deviation did not increase as a function of time in use. This study has demonstrated that the iPad display exhibits luminance degradation typical of liquid crystal displays. The Lmax of the iPad fell below the American College of Radiology-AAPM-Society of Imaging Informatics in Medicine recommendations for primary displays (>350 cdm(-2)) at approximately 1000 h in use. The Lmax recommendation for secondary displays (>250 cdm(-2)) was exceeded during the entire study. The maximum non-uniformity coefficient did not exceed the recommendations for either primary or secondary displays. The deviation from the GSDF exceeded the recommendations of the TG18 for use as either a primary or secondary display. The brightness, uniformity and contrast response are reasonably stable over the useful lifetime of the device; however, the device fails to meet the contrast response standard for either a primary or secondary display.

  13. Sedimentation Survey of Lago de Cidra, Puerto Rico, August 2007

    USGS Publications Warehouse

    Soler-López, Luis R.

    2010-01-01

    Lago de Cidra is a reservoir located on the confluence of Rio de Bayamon, Rio Sabana, and Quebrada Prieta, in the municipality of Cidra in east-central Puerto Rico, about 3.0 kilometers northeast of the town of Cidra. The dam is owned and operated by the Puerto Rico Aqueduct and Sewer Authority (PRASA), and was constructed in 1946 as a 6.54-million-cubic-meter supplemental water supply for the San Juan metropolitan area. The reservoir impounds the waters of Rio de Bayamon, Rio Sabana and Quebrada Prieta. The reservoir has a drainage area of 21.4 square kilometers. The dam is a concrete gravity and earthfill structure with a length of approximately 165 meters and a structural height of 24 meters. The spillway portion of the dam is an ungated ogee crest about 40 meters long with a crest elevation of 403.00 meters above mean sea level. Additional information and operational procedures are listed in Soler-Lopez (1999). During August 14-15, 2007, the U.S. Geological Survey (USGS), Caribbean Water Science Center (CWSC), in cooperation with the PRASA, conducted a bathymetric survey of Lago de Cidra to update the reservoir storage capacity and actualize the reservoir sedimentation rate by comparing the 2007 data with the previous 1997 bathymetric survey data. The purpose of this report is to describe and document the USGS sedimentation survey conducted at Lago de Cidra during August 2007, including the methods used to update the reservoir storage capacity, sedimentation rates, and areas of substantial sediment accumulation since 1997.

  14. Exploring the limits of crop productivity. I. Photosynthetic efficiency of wheat in high irradiance environments

    NASA Technical Reports Server (NTRS)

    Bugbee, B. G.; Salisbury, F. B.

    1988-01-01

    The long-term vegetative and reproductive growth rates of a wheat crop (Triticum aestivum L.) were determined in three separate studies (24, 45, and 79 days) in response to a wide range of photosynthetic photon fluxes (PPF, 400-2080 micromoles per square meter per second; 22-150 moles per square meter per day; 16-20 hour photoperiod) in a near-optimum, controlled-environment. The CO2 concentration was elevated to 1200 micromoles per mole, and water and nutrients were supplied by liquid hydroponic culture. An unusually high plant density (2000 plants per square meter) was used to obtain high yields. Crop growth rate and grain yield reached 138 and 60 grams per square meter per day, respectively; both continued to increase up to the highest integrated daily PPF level, which was three times greater than a typical daily flux in the field. The conversion efficiency of photosynthesis (energy in biomass/energy in photosynthetic photons) was over 10% at low PPF but decreased to 7% as PPF increased. Harvest index increased from 41 to 44% as PPF increased. Yield components for primary, secondary, and tertiary culms were analyzed separately. Tillering produced up to 7000 heads per square meter at the highest PPF level. Primary and secondary culms were 10% more efficient (higher harvest index) than tertiary culms; hence cultural, environmental, or genetic changes that increase the percentage of primary and secondary culms might increase harvest index and thus grain yield. Wheat is physiologically and genetically capable of much higher productivity and photosynthetic efficiency than has been recorded in a field environment.

  15. Anti-Adhesion Elastomer Seal Coatings for Ultraviolet and Atomic Oxygen Protection

    NASA Technical Reports Server (NTRS)

    De Groh, Henry C., III; Puleo, Bernadette J.; Waters, Deborah L.; Miller, Sharon K.

    2015-01-01

    Radiation blocking sunscreen coatings have been developed for the protection of elastomer seals used in low-Earth-orbit (LEO). The coatings protect the seals from ultraviolet (UV) radiation and atomic oxygen (AO) damage. The coatings were developed for use on NASA docking seals. Docking seal damage from the UV and AO present in LEO can constrain mission time-line, flight mode options, and increases risk. A low level of adhesion is also required for docking seals so undocking push-off forces can be low. The coatings presented also mitigate this unwanted adhesion. Greases with low collected volatile condensable materials (CVCM) and low total mass loss (TML) were mixed with slippery and/or UV blocking powders to create the protective coatings. Coatings were applied at rates up to 2 milligrams per square centimeter. Coated seals were exposed to AO and UV in the NUV (near-UV) and UV-C wavelength ranges (300 to 400 nanometers and 254 nanometers, respectively). Ground based ashers were used to simulate the AO of space. The Sun's UV energy was mimicked assuming a nose forward flight mode, resulting in an exposure rate of 2.5 megajoules per square meter per day. Exposures between 0 and 147 megajoules per square meter (UV-C) and 245 megajoules per square meter (NUV) were accomplished. The protective coatings were durable, providing protection from UV after a simulated docking and undocking cycle. The level of protection begins to decline at coverage rates less than 0.9 milligrams per square centimeter. The leakage of seals coated with Braycote plus 20 percent Z-cote ZnO sunscreen increased by a factor of 40 after moderate AO exposure; indicating that this coating might not be suitable due to AO intolerance. Seals coated with DC-7-16.4 percent Z-cote ZnO sunscreen were not significantly affected by combined doses of 2 x 10 (sup 21) atoms per square AO with 73 megajoules per square meter UV-C. Unprotected seals were significantly damaged at UV-C exposures of 0.3 megajoules per square meter and DC-7-16.4 percent Z-cote coated seals were undamaged at all exposures up to the limits tested thus far which were 147 megajoules per square meter UV-C and 245 megajoules per square meter NUV. The coatings decreased adhesion sufficiently for docking seals at temperatures equal to or greater than -8 degrees Centigrade thus offer a simple and inexpensive way to mitigate adhesion.

  16. Petrology and Eruptive Styles of Central WA Teanaway Basalt: Uplift and Bimodal Volcanism in Subsiding Eocene Basin

    NASA Astrophysics Data System (ADS)

    Ivener, D.; Tepper, J. H.

    2013-12-01

    The 47 Ma Teanaway Basalt (TB) is a bimodal unit that erupted in Central Washington during the poorly-understood Challis Event. The TB consists of over 2500 meters of subaerial mafic flows, hyaloclastite, rhyolite domes, and tuff. In order to better understand the origin and tectonic setting of the TB, we have studied three localities that encompass the geographic extent of the unit: Easton Ridge (ER), Teanaway River Middle Fork (MF), and Liberty Ridge (LR). The TB lies stratigraphically between two thick arkosic sedimentary units (Swauk and Roslyn Formations) that are thought to have accumulated in a rapidly subsiding basin (Tabor et al., 1990). The gently-dipping, 380 meter thick, MF section is comprised of subaerial flows interbedded with hyaloclastite layers; no pillows were observed. These observations suggest that the TB erupted in shallow water and that the rate of subsidence was approximately equal to the rate of construction. In addition, the absence of arkosic interbeds within the MF section suggests that the sediment supply to the basin was interrupted during TB eruptions and/or that the basin was a highland during this period. Based on tectonic reconstructions (Heller et al., 1987), which place the Kula-Farallon Ridge in this area during the Eocene, we suggest that uplift during TB magmatism is a result of ridge subduction. Furthermore, the evidence of extensional dikes at a convergent margin can be accounted for by the subduction of a spreading ridge. Mafic TB lavas are moderately evolved (45.2 - 63.1 wt. % SiO2, Mg # = 0.13-0.48). These rocks are aphanitic to very fine-grained with sparse phenocrysts of plagioclase. These flows are commonly either massive or display spectacular columnar jointing and range in thickness from less than two feet to almost 150 feet (Clayton, 1973). They show extensive compositional overlap with dikes in the underlying Swauk Formation although the dikes tend to be slightly more primitive. These data support interpretation of the dikes as feeders for the overlying flows. Rhyolites within the TB have 73.0 - 79.4 wt. % SiO2, Mg# = 0.27 - 0.01, and 3.2-5.1 wt. % K2O. Relative to the associated basalts these rocks display larger negative Eu anomalies (Eu/Eu* = 0.36 to 0.70), steeper La/Sm, and lower HREE. MELTS modeling suggests that TB rhyolites can be derived from a TB basaltic andesite parent via at least 60% fractional crystallization that is dominated by plagioclase, pyroxene, and spinel formation. These modeled rhyolites compositionally match TB rhyolites (excluding CaO content) best when starting with 3.0 wt. % H2O and forming at 10kb.

  17. Comparison of accuracy of fibrosis degree classifications by liver biopsy and non-invasive tests in chronic hepatitis C.

    PubMed

    Boursier, Jérôme; Bertrais, Sandrine; Oberti, Frédéric; Gallois, Yves; Fouchard-Hubert, Isabelle; Rousselet, Marie-Christine; Zarski, Jean-Pierre; Calès, Paul

    2011-11-30

    Non-invasive tests have been constructed and evaluated mainly for binary diagnoses such as significant fibrosis. Recently, detailed fibrosis classifications for several non-invasive tests have been developed, but their accuracy has not been thoroughly evaluated in comparison to liver biopsy, especially in clinical practice and for Fibroscan. Therefore, the main aim of the present study was to evaluate the accuracy of detailed fibrosis classifications available for non-invasive tests and liver biopsy. The secondary aim was to validate these accuracies in independent populations. Four HCV populations provided 2,068 patients with liver biopsy, four different pathologist skill-levels and non-invasive tests. Results were expressed as percentages of correctly classified patients. In population #1 including 205 patients and comparing liver biopsy (reference: consensus reading by two experts) and blood tests, Metavir fibrosis (FM) stage accuracy was 64.4% in local pathologists vs. 82.2% (p < 10-3) in single expert pathologist. Significant discrepancy (≥ 2FM vs reference histological result) rates were: Fibrotest: 17.2%, FibroMeter2G: 5.6%, local pathologists: 4.9%, FibroMeter3G: 0.5%, expert pathologist: 0% (p < 10-3). In population #2 including 1,056 patients and comparing blood tests, the discrepancy scores, taking into account the error magnitude, of detailed fibrosis classification were significantly different between FibroMeter2G (0.30 ± 0.55) and FibroMeter3G (0.14 ± 0.37, p < 10-3) or Fibrotest (0.84 ± 0.80, p < 10-3). In population #3 (and #4) including 458 (359) patients and comparing blood tests and Fibroscan, accuracies of detailed fibrosis classification were, respectively: Fibrotest: 42.5% (33.5%), Fibroscan: 64.9% (50.7%), FibroMeter2G: 68.7% (68.2%), FibroMeter3G: 77.1% (83.4%), p < 10-3 (p < 10-3). Significant discrepancy (≥ 2 FM) rates were, respectively: Fibrotest: 21.3% (22.2%), Fibroscan: 12.9% (12.3%), FibroMeter2G: 5.7% (6.0%), FibroMeter3G: 0.9% (0.9%), p < 10-3 (p < 10-3). The accuracy in detailed fibrosis classification of the best-performing blood test outperforms liver biopsy read by a local pathologist, i.e., in clinical practice; however, the classification precision is apparently lesser. This detailed classification accuracy is much lower than that of significant fibrosis with Fibroscan and even Fibrotest but higher with FibroMeter3G. FibroMeter classification accuracy was significantly higher than those of other non-invasive tests. Finally, for hepatitis C evaluation in clinical practice, fibrosis degree can be evaluated using an accurate blood test.

  18. Comparison of accuracy of fibrosis degree classifications by liver biopsy and non-invasive tests in chronic hepatitis C

    PubMed Central

    2011-01-01

    Background Non-invasive tests have been constructed and evaluated mainly for binary diagnoses such as significant fibrosis. Recently, detailed fibrosis classifications for several non-invasive tests have been developed, but their accuracy has not been thoroughly evaluated in comparison to liver biopsy, especially in clinical practice and for Fibroscan. Therefore, the main aim of the present study was to evaluate the accuracy of detailed fibrosis classifications available for non-invasive tests and liver biopsy. The secondary aim was to validate these accuracies in independent populations. Methods Four HCV populations provided 2,068 patients with liver biopsy, four different pathologist skill-levels and non-invasive tests. Results were expressed as percentages of correctly classified patients. Results In population #1 including 205 patients and comparing liver biopsy (reference: consensus reading by two experts) and blood tests, Metavir fibrosis (FM) stage accuracy was 64.4% in local pathologists vs. 82.2% (p < 10-3) in single expert pathologist. Significant discrepancy (≥ 2FM vs reference histological result) rates were: Fibrotest: 17.2%, FibroMeter2G: 5.6%, local pathologists: 4.9%, FibroMeter3G: 0.5%, expert pathologist: 0% (p < 10-3). In population #2 including 1,056 patients and comparing blood tests, the discrepancy scores, taking into account the error magnitude, of detailed fibrosis classification were significantly different between FibroMeter2G (0.30 ± 0.55) and FibroMeter3G (0.14 ± 0.37, p < 10-3) or Fibrotest (0.84 ± 0.80, p < 10-3). In population #3 (and #4) including 458 (359) patients and comparing blood tests and Fibroscan, accuracies of detailed fibrosis classification were, respectively: Fibrotest: 42.5% (33.5%), Fibroscan: 64.9% (50.7%), FibroMeter2G: 68.7% (68.2%), FibroMeter3G: 77.1% (83.4%), p < 10-3 (p < 10-3). Significant discrepancy (≥ 2 FM) rates were, respectively: Fibrotest: 21.3% (22.2%), Fibroscan: 12.9% (12.3%), FibroMeter2G: 5.7% (6.0%), FibroMeter3G: 0.9% (0.9%), p < 10-3 (p < 10-3). Conclusions The accuracy in detailed fibrosis classification of the best-performing blood test outperforms liver biopsy read by a local pathologist, i.e., in clinical practice; however, the classification precision is apparently lesser. This detailed classification accuracy is much lower than that of significant fibrosis with Fibroscan and even Fibrotest but higher with FibroMeter3G. FibroMeter classification accuracy was significantly higher than those of other non-invasive tests. Finally, for hepatitis C evaluation in clinical practice, fibrosis degree can be evaluated using an accurate blood test. PMID:22129438

  19. Alternative Fuels Data Center

    Science.gov Websites

    Charging Rate Incentive - Georgia Power Georgia Power offers a Plug-in Electric Vehicle (PEV) time -of-use electricity rate for residential customers who own an electric or plug-in hybrid electric vehicle. The PEV rate is optional and does not require a separate meter. For more information, see the

  20. Present-day Exposures of Water Ice in the Northern Mid-latitudes of Mars

    NASA Technical Reports Server (NTRS)

    Allen, Carlton C.; Kanner, Lisa C.

    2007-01-01

    Water ice is exposed in the martian north polar cap, but is rarely exposed beyond the cap boundary. Orbital gamma ray spectrometry data strongly imply the presence of water ice within meters of the surface at latitudes north of approximately 60deg. We have examined mid-latitude areas of the northern plains displaying residual ice-rich layers, and report evidence of present-day surface exposures of water ice. These exposures, if confirmed, could con-strain the latitudinal and temporal stability of surface ice on Mars.

  1. Developing the Federal Aviation Administration’s Requirements for Color Use in Air Traffic Control Displays

    DTIC Science & Technology

    2007-05-01

    colorimeter . The relationship between rgb and xyL values can be specified with a nonlinear transformation and a linear matrix transformation, as described by...situation where users 1) know the rgb values of the colors, 2) have a colorimeter or luminance meter to measure luminance, 3) are capable of generating...the center of the screen while keeping the rest of the screen black (specified by r=g=b=0). Step 1A.3: Hold the colorimeter at users’ typical view

  2. Independent Orbiter Assessment (IOA): Analysis of the displays and controls subsystem

    NASA Technical Reports Server (NTRS)

    Trahan, W. H.; Prust, E. E.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Displays and Controls (D and C) subsystem hardware. The function of the D and C hardware is to provide the crew with the monitor, command, and control capabilities required for management of all normal and contingency mission and flight operations. The D and C hardware for which failure modes analysis was performed consists of the following: Acceleration Indicator (G-METER); Head Up Display (HUD); Display Driver Unit (DDU); Alpha/Mach Indicator (AMI); Horizontal Situation Indicator (HSI); Attitude Director Indicator (ADI); Propellant Quantity Indicator (PQI); Surface Position Indicator (SPI); Altitude/Vertical Velocity Indicator (AVVI); Caution and Warning Assembly (CWA); Annunciator Control Assembly (ACA); Event Timer (ET); Mission Timer (MT); Interior Lighting; and Exterior Lighting. Each hardware item was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

  3. NO sub X Deposited in the Stratosphere by the Space Shuttle Solid Rocket Motors

    NASA Technical Reports Server (NTRS)

    Pergament, H. S.; Thorpe, R. D.; Hwang, B.

    1975-01-01

    The possible effects of the interaction of the plumes from the two solid rocket motors (SRM) from the space shuttles and mixing of the rocket exhaust products and ambient air in the base recirculation region on the total nitrous oxide deposition rate in the stratosphere were investigated. It was shown that these phenomena will not influence the total NOx deposition rate. It was also shown that uncertainties in the particle size of Al2O3, size distributions and particle/gas drag and heat transfer coefficients will not have a significant effect on the predicted NOx deposition rate. The final results show that the total mass flow of NOx leaving the plume at 30 km altitude is 4000 g./sec with a possible error factor of 3. For a vehicle velocity of 1140 meter/sec this yields an NOx deposition rate of about 3.5 g./meter. The corresponding HCl deposition rate at this altitude is about a factor of 500 greater than this value.

  4. Ka-Band Parabolic Deployable Antenna (KaPDA) Enabling High Speed Data Communication for CubeSats

    NASA Technical Reports Server (NTRS)

    Sauder, Jonathan F.; Chahat, Nacer; Hodges, Richard; Thomson, Mark W.; Rahmat-Samii, Yahya

    2015-01-01

    CubeSats are at a very exciting point as their mission capabilities and launch opportunities are increasing. But as instruments become more advanced and operational distances between CubeSats and earth increase communication data rate becomes a mission-limiting factor. Improving data rate has become critical enough for NASA to sponsor the Cube Quest Centennial Challenge when: one of the key metrics is transmitting as much data as possible from the moon and beyond Currently, many CubeSats communicate on UHF bands and those that have high data rate abilities use S-band or X-band patch antennas. The CubeSat Aneas, which was launched in September 2012, pushed the envelope with a half-meter S-band dish which could achieve 100x the data rate of patch antennas. A half-meter parabolic antenna operating at Ka-band would increase data rates by over 100x that of the AMOS antenM and 10,000 that of X-band patch antennas.

  5. Long-range non-contact imaging photoplethysmography: cardiac pulse wave sensing at a distance

    NASA Astrophysics Data System (ADS)

    Blackford, Ethan B.; Estepp, Justin R.; Piasecki, Alyssa M.; Bowers, Margaret A.; Klosterman, Samantha L.

    2016-03-01

    Non-contact, imaging photoplethysmography uses photo-optical sensors to measure variations in light absorption, caused by blood volume pulsations, to assess cardiopulmonary parameters including pulse rate, pulse rate variability, and respiration rate. Recently, researchers have studied the applications and methodology of imaging photoplethysmography. Basic research has examined some of the variables affecting data quality and accuracy of imaging photoplethysmography including signal processing, imager parameters (e.g. frame rate and resolution), lighting conditions, subject motion, and subject skin tone. This technology may be beneficial for long term or continuous monitoring where contact measurements may be harmful (e.g. skin sensitivities) or where imperceptible or unobtrusive measurements are desirable. Using previously validated signal processing methods, we examined the effects of imager-to-subject distance on one-minute, windowed estimates of pulse rate. High-resolution video of 22, stationary participants was collected using an enthusiast-grade, mirrorless, digital camera equipped with a fully-manual, super-telephoto lens at distances of 25, 50, and 100 meters with simultaneous contact measurements of electrocardiography, and fingertip photoplethysmography. By comparison, previous studies have usually been conducted with imager-to-subject distances of up to only a few meters. Mean absolute error for one-minute, windowed, pulse rate estimates (compared to those derived from gold-standard electrocardiography) were 2.0, 4.1, and 10.9 beats per minute at distances of 25, 50, and 100 meters, respectively. Long-range imaging presents several unique challenges among which include decreased, observed light reflectance and smaller regions of interest. Nevertheless, these results demonstrate that accurate pulse rate measurements can be obtained from over long imager-to-participant distances given these constraints.

  6. Plotting Rates of Photosynthesis as a Function of Light Quantity.

    ERIC Educational Resources Information Center

    Dean, Rob L.

    1996-01-01

    Discusses methods for plotting rates of photosynthesis as a function of light quantity. Presents evidence that suggests that empirically derived conversion factors, which are used to convert foot candles to photon fluence rates, should be used with extreme caution. Suggests how rate data are best plotted when any kind of light meter is not…

  7. Modeled and measured glacier change and related glaciological, hydrological, and meteorological conditions at South Cascade Glacier, Washington, balance and water years 2006 and 2007

    USGS Publications Warehouse

    Bidlake, William R.; Josberger, Edward G.; Savoca, Mark E.

    2010-01-01

    Winter snow accumulation and summer snow and ice ablation were measured at South Cascade Glacier, Washington, to estimate glacier mass balance quantities for balance years 2006 and 2007. Mass balances were computed with assistance from a new model that was based on the works of other glacier researchers. The model, which was developed for mass balance practitioners, coupled selected meteorological and glaciological data to systematically estimate daily mass balance at selected glacier sites. The North Cascade Range in the vicinity of South Cascade Glacier accumulated approximately average to above average winter snow packs during 2006 and 2007. Correspondingly, the balance years 2006 and 2007 maximum winter snow mass balances of South Cascade Glacier, 2.61 and 3.41 meters water equivalent, respectively, were approximately equal to or more positive (larger) than the average of such balances since 1959. The 2006 glacier summer balance, -4.20 meters water equivalent, was among the four most negative since 1959. The 2007 glacier summer balance, -3.63 meters water equivalent, was among the 14 most negative since 1959. The glacier continued to lose mass during 2006 and 2007, as it commonly has since 1953, but the loss was much smaller during 2007 than during 2006. The 2006 glacier net balance, -1.59 meters water equivalent, was 1.02 meters water equivalent more negative (smaller) than the average during 1953-2005. The 2007 glacier net balance, -0.22 meters water equivalent, was 0.37 meters water equivalent less negative (larger) than the average during 1953-2006. The 2006 accumulation area ratio was less than 0.10, owing to isolated patches of accumulated snow that endured the 2006 summer season. The 2006 equilibrium line altitude was higher than the glacier. The 2007 accumulation area ratio and equilibrium line altitude were 0.60 and 1,880 meters, respectively. Accompanying the glacier mass losses were retreat of the terminus and reduction of total glacier area. The terminus retreated at a rate of about 13 meters per year during balance year 2006 and at a rate of about 8 meters per year during balance year 2007. Glacier area near the end of balance years 2006 and 2007 was 1.74 and 1.73 square kilometers, respectively. Runoff from the basin containing the glacier and from an adjacent nonglacierized basin was gaged during all or parts of water years 2006 and 2007. Air temperature, wind speed, precipitation, and incoming solar radiation were measured at selected locations on and near the glacier. Air-temperature over the glacier at a height of 2 meters generally was less than at the same altitude in the air mass away from the glacier. Cooling of the air by the glacier increased systematically with increasing ambient air temperature. Empirically based equations were developed to estimate 2-meter-height air temperature over the glacier at five sites from site altitude and temperature at a non-glacier reference site.

  8. Calculation of Flight Deck Interval Management Assigned Spacing Goals Subject to Multiple Scheduling Constraints

    NASA Technical Reports Server (NTRS)

    Robinson, John E.

    2014-01-01

    The Federal Aviation Administration's Next Generation Air Transportation System will combine advanced air traffic management technologies, performance-based procedures, and state-of-the-art avionics to maintain efficient operations throughout the entire arrival phase of flight. Flight deck Interval Management (FIM) operations are expected to use sophisticated airborne spacing capabilities to meet precise in-trail spacing from top-of-descent to touchdown. Recent human-in-the-loop simulations by the National Aeronautics and Space Administration have found that selection of the assigned spacing goal using the runway schedule can lead to premature interruptions of the FIM operation during periods of high traffic demand. This study compares three methods for calculating the assigned spacing goal for a FIM operation that is also subject to time-based metering constraints. The particular paradigms investigated include: one based upon the desired runway spacing interval, one based upon the desired meter fix spacing interval, and a composite method that combines both intervals. These three paradigms are evaluated for the primary arrival procedures to Phoenix Sky Harbor International Airport using the entire set of Rapid Update Cycle wind forecasts from 2011. For typical meter fix and runway spacing intervals, the runway- and meter fix-based paradigms exhibit moderate FIM interruption rates due to their inability to consider multiple metering constraints. The addition of larger separation buffers decreases the FIM interruption rate but also significantly reduces the achievable runway throughput. The composite paradigm causes no FIM interruptions, and maintains higher runway throughput more often than the other paradigms. A key implication of the results with respect to time-based metering is that FIM operations using a single assigned spacing goal will not allow reduction of the arrival schedule's excess spacing buffer. Alternative solutions for conducting the FIM operation in a manner more compatible with the arrival schedule are discussed in detail.

  9. Orbital and Physical Characteristics of Meter-sized Earth Impactors

    NASA Astrophysics Data System (ADS)

    Brown, Peter G.; Wiegert, Paul; Clark, David; Tagliaferri, Edward

    2015-11-01

    We have analysed the orbits and ablation characteristics in the atmosphere of more than 60 earth-impacting meteoroids of one meter in diameter or larger. Using heights at peak luminosity as a proxy for strength, we find that there is roughly an order of magnitude spread in the apparent strength of the population of meter-sized impactors at the Earth. The orbits and physical strength of these objects are consistent with the majority being asteroidal bodies originating from the inner main asteroid belt. We find ~10-15% of our objects have a probable cometary (Jupiter-Family comet and/or Halley-type comet) origin based on orbital characteristics alone. Only half this number, however, show evidence for the expected weaker than average structure compared to asteroidal bodies. Almost all impactors show peak brightness between 20-40 km altitude. Several events have exceptionally high (relative to the remainder of the population) heights of peak brightness. These are physically most consistent with high microporosity objects, though all were on asteroidal-type orbits. We also find three events, including the Oct 8, 2009 airburst near Sulawesi, Indonesia, which display comparatively low heights of peak brightness, consistent with strong monolithic stones or iron meteoroids. Based on orbital similarity, we find a probable connection among several NEOs in our population with the Taurid meteoroid complex. No other major meteoroid streams show linkages with the pre-atmospheric orbits of our meter-class impactors. Our events cover almost four orders of magnitude in mass, but no trend in height of peak brightness is evident, suggesting no strong trend in strength with size for small NEOs, a finding consistent with the results of Popova et al (2011).

  10. Looking Toward Curiosity Study Areas, Spring 2015

    NASA Image and Video Library

    2015-05-08

    This detailed panorama from the Mast Camera (Mastcam) on NASA's Curiosity Mars rover shows a view toward two areas on lower Mount Sharp chosen for close-up inspection: "Mount Shields" and "Logan Pass." The scene is a mosaic of images taken with Mastcam's right-eye camera, which has a telephoto lens, on April 16, 2015, during the 957th Martian day, or sol, of Curiosity's work on Mars, before that sol's drive. The view spans from southwest, at left, to west-northwest. The color has been approximately white-balanced to resemble how the scene would appear under daytime lighting conditions on Earth. By 10 sols later, Curiosity had driven about 328 meters (1,076 feet) from the location where it made this observation to an outcrop at the base of "Mount Shields." A 5-meter scale bar has been superimposed near the center of this scene beside the outcrop that the rover then examined in detail. (Five meters is 16.4 feet.) This study location was chosen on the basis of Mount Shields displaying a feature that geologists recognized from images like this as likely to be a site where an ancient valley was incised into bedrock, then refilled with other sediment. After a few sols examining the outcrop at the base of Mount Shields, Curiosity resumed driving toward a study area at Logan Pass, near the 5-meter scale bar in the left half of this scene. That location was selected earlier, on the basis of images from orbit indicating contact there between two different geological units. The rover's route from Mount Shields to Logan Pass runs behind "Jocko Butte" from the viewpoint where this panorama was taken. http://photojournal.jpl.nasa.gov/catalog/PIA19398

  11. An Approach to the Quantitative Study of Sea Floor Topography.

    DTIC Science & Technology

    1980-01-01

    Basement in the Pacific Ocean MAGNETIC TOTAL RMS ANOMALY SPREADING RELIEF MEAN RMS RIDGE WINDOW RATE (cm/yr) (meters) RELIEF (meters) Nazca-Cocos 0-2’ 6 104...investigation. V. CONCLUSIONS The sea floor and the lithologic boundaries below it can generally be thought of as interfaces of acoustic impedance mismatch... Magnetic Anomalies , and Plate Tectonic History of the Mouth of the Gulf of California. Geol. Soc. Am. Bull., v. 83, p. 3345-3360. Luyendyk, B. P

  12. 40 CFR 1066.1005 - Symbols, abbreviations, acronyms, and units of measure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... joule per kelvin J/K J · K−1 C v heat capacity at constant volume joule per kelvin J/K J · K−1 d... m3 Q flow rate cubic feet per minute or cubic meter per second ft3/min or m3/s m3/s r mass density... · s−1 V volume cubic meter m3 m3 VP volume percent x concentration of emission over a test interval...

  13. The Cardiovascular Function Profile and Physical Fitness in Overweight Subjects

    NASA Astrophysics Data System (ADS)

    Megawati, E. R.; Lubis, L. D.; Harahap, F. Y.

    2017-03-01

    Obesity in children and young adult is associated with cardiovascular risk in short term and long term. The aim of this study was to describe the profile of the cardiovascular functions parameters and physical fitness in overweight. This is an analytical observational study with cross sectional approach. The samples of this study were 85 randomly selected subjects aged 18 to 24 years with normoweight and body mass index <40. The parameters measures were body mass index (BMI), waist circumference (WC), waist-hip ratio (WHR), cardiovascular function parameters (resting pulse, blood pressure, and peak flow meter) and physical fitness parameters (VO2max dengan McArdle step test). The mean BMI was 24,53±4,929. The WC and WHR mean were 86,7±14,10 cms and 0,89±0,073 cm respectively. The mean of resting pulses were higher in normoweight subject (p=0,0209). The mean systole were lower in normoweight subject (p=0,0026). No differences VO2 max between groups (p=0,3888). The peak flow meter was higher in normoweight (p=0,0274). The result of this study indicate that heart rate, systole and peak flow meter are signifantly different between groups. The heart rate and the peak flow meter in the overweight subjects were lower meanwhile the systole blood pressure was higher compared to normoweight subjects.

  14. Anatomy Of The ‘LuSi’ Mud Eruption, East Java

    NASA Astrophysics Data System (ADS)

    Tingay, M. R.

    2009-12-01

    Early in the morning of the 29th of May 2006, hot mud started erupting from the ground in the densely populated Porong District of Sidoarjo, East Java. With initial flow rates of ~5000 cubic meters per day, the mud quickly inundated neighbouring villages. Over two years later and the ‘Lusi’ eruption has increased in strength, expelling over 90 million cubic meters of mud at an average rate of approximately 100000 cubic meters per day. The mud flow has now covered over 700 hectares of land to depths of over 25 meters, engulfing a dozen villages and displacing approximately 40000 people. In addition to the inundated areas, other areas are also at risk from subsidence and distant eruptions of gas. However, efforts to stem the mud flow or monitor its evolution are hampered by our overall lack of knowledge and consensus on the subsurface anatomy of the Lusi mud volcanic system. In particular, the largest and most significant uncertainties are the source of the erupted water (shales versus deep carbonates), the fluid flow pathways (purely fractures versus mixed fracture and wellbore) and disputes over the subsurface geology (nature of deep carbonates, lithology of rocks between shale and carbonates). This study will present and overview of the anatomy of the Lusi mud volcanic system with particular emphasis on these critical uncertainties and their influence on the likely evolution of disaster.

  15. Robotic crabs reveal that female fiddler crabs are sensitive to changes in male display rate.

    PubMed

    Mowles, Sophie L; Jennions, Michael D; Backwell, Patricia R Y

    2018-01-01

    Males often produce dynamic, repetitive courtship displays that can be demanding to perform and might advertise male quality to females. A key feature of demanding displays is that they can change in intensity: escalating as a male increases his signalling effort, but de-escalating as a signaller becomes fatigued. Here, we investigated whether female fiddler crabs, Uca mjoebergi , are sensitive to changes in male courtship wave rate. We performed playback experiments using robotic male crabs that had the same mean wave rate, but either escalated, de-escalated or remained constant. Females demonstrated a strong preference for escalating robots, but showed mixed responses to robots that de-escalated ('fast' to 'slow') compared to those that waved at a constant 'medium' rate. These findings demonstrate that females can discern changes in male display rate, and prefer males that escalate, but that females are also sensitive to past display rates indicative of prior vigour. © 2018 The Authors.

  16. Evaluating the risk of decompression sickness for a yo-yo dive using a rat model.

    PubMed

    Ofir, Dror; Yanir, Yoav; Abramovich, Amir; Bar, Ronen; Arieli, Yehuda

    2016-01-01

    The frequent ascents made during yo-yo diving may contribute to gas bubble clearance but paradoxically may also increase the risk of central nervous system decompression illness (DCI). We evaluated the risk of DCI due to yo-yo dives with very short surface intervals, using a controlled animal model. Dives were conducted on air to a depth of 90 meters (10 atmospheres absolute) for 32 minutes of bottom time, at a descent/ascent rate of 10 meters/ minute. Sprague-Dawley rats weighing ~ 300 grams were divided randomly into three groups. Group A performed a square dive protocol without any surface intervals, Group B conducted a protocol that included two surface intervals during the dive, and Group C performed a protocol with three surface intervals. Ascent/descent rate for surface intervals, each lasting one minute, was also 10 meters/minute. Manifestations of DCI were observed in 13 of 16 animals in Group A (81.3%), six of 12 in Group B (58.3%), and two of 12 in Group C (16.7%). Mortality rates were similar in all groups. Surface intervals during dives breathing air significantly reduced DCI risk in the rat. Further studies are required using a larger animal model to reinforce the results of the present investigation.

  17. Test techniques for evaluating flight displays

    NASA Technical Reports Server (NTRS)

    Haworth, Loran A.; Newman, Richard L.

    1993-01-01

    The rapid development of graphics technology allows for greater flexibility in aircraft displays, but display evaluation techniques have not kept pace. Historically, display evaluation has been based on subjective opinion and not on the actual aircraft/pilot performance. Existing electronic display specifications and evaluation techniques are reviewed. A display rating technique analogous to handling qualities ratings was developed and is recommended for future evaluations. The choice of evaluation pilots is also discussed and the use of a limited number of trained evaluators is recommended over the use of a large number of operational pilots.

  18. Cryogenic flow rate measurement with a laser Doppler velocimetry standard

    NASA Astrophysics Data System (ADS)

    Maury, R.; Strzelecki, A.; Auclercq, C.; Lehot, Y.; Loubat, S.; Chevalier, J.; Ben Rayana, F.

    2018-03-01

    A very promising alternative to the state-of-the-art static volume measurements for liquefied natural gas (LNG) custody transfer processes is the dynamic principle of flow metering. As the Designated Institute (DI) of the LNE (‘Laboratoire National de métrologie et d’Essais’, being the French National Metrology Institute) for high-pressure gas flow metering, Cesame-Exadebit is involved in various research and development programs. Within the framework of the first (2010-2013) and second (2014-2017) EURAMET Joint Research Project (JRP), named ‘Metrological support for LNG custody transfer and transport fuel applications’, Cesame-Exadebit explored a novel cryogenic flow metering technology using laser Doppler velocimetry (LDV) as an alternative to ultrasonic and Coriolis flow metering. Cesame-Exadebit is trying to develop this technique as a primary standard for cryogenic flow meters. Currently, cryogenic flow meters are calibrated at ambient temperatures with water. Results are then extrapolated to be in the Reynolds number range of real applications. The LDV standard offers a unique capability to perform online calibration of cryogenic flow meters in real conditions (temperature, pressure, piping and real flow disturbances). The primary reference has been tested on an industrial process in a LNG terminal during truck refuelling. The reference can calibrate Coriolis flow meters being used daily with all the real environmental constraints, and its utilisation is transparent for LNG terminal operators. The standard is traceable to Standard International units and the combined extended uncertainties have been determined and estimated to be lower than 0.6% (an ongoing improvement to reducing the correlation function uncertainty, which has a major impact in the uncertainty estimation).

  19. BLAST for Behind-the-Meter Applications Lite Tool | Transportation Research

    Science.gov Websites

    provided by NREL's PV Watts calculator. A generic utility rate structure framework makes it possible to the BLAST documentation for proper CSV formatting. Rate structure values Define demand charges and energy costs to best represent your utility rate structure of interest. Demand charges and energy costs

  20. Remote Measurement of Atmospheric Temperatures By Raman Lidar

    NASA Technical Reports Server (NTRS)

    Salzman, Jack A.; Coney, Thom A.

    1973-01-01

    The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

  1. Development of simple band-spectral pyranometer and quantum meter using photovoltaic cells and bandpass filters

    NASA Astrophysics Data System (ADS)

    Bilguun, Amarsaikhan; Nakaso, Tetsushi; Harigai, Toru; Suda, Yoshiyuki; Takikawa, Hirofumi; Tanoue, Hideto

    2016-02-01

    In recent years, greenhouse automatic-control, based on the measurement of solar irradiance, has been attracting attention. This control is an effective method for improving crop production. In the agricultural field, it is necessary to measure Photon Flux Density (PFD), which is an important parameter in the promotion of plant growth. In particular, the PFD of Photosynthetically Active Radiation (PAR, 400-700 nm) and Plant Biologically Active Radiation (PBAR, 300-800 nm) have been discussed in agricultural plant science. The commercial quantum meter (QM, PAR meter) can only measure Photosynthetically Photon Flux Density (PPFD) which is the integrated PFD quantity on the PAR wavelength. In this research, a band-spectral pyranometer or quantum meter using PVs with optical bandpass filters for dividing the PBAR wavelength into 100 nm bands (five independent channels) was developed. Before field testing, calibration of the instruments was carried out using a solar simulator. Next, a field test was conducted in three differing weather conditions such as clear, partly cloudy and cloudy skies. As a result, it was found that the response rate of the developed pyranometer was faster by four seconds compared with the response rate of the commercial pyranometer. Moreover, the outputs of each channel in the developed pyranometer were very similar to the integrated outputs of the commercial spectroradiometer. It was confirmed that the solar irradiance could be measured in each band separately using the developed band-spectral pyranometer. It was indicated that the developed band-spectral pyranometer could also be used as a PV band-spectral quantum meter which is obtained by converting the band irradiance into band PFD.

  2. Development of simple band-spectral pyranometer and quantum meter using photovoltaic cells and bandpass filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilguun, Amarsaikhan, E-mail: bilguun@pes.ee.tut.ac.jp; Nakaso, Tetsushi; Harigai, Toru

    In recent years, greenhouse automatic-control, based on the measurement of solar irradiance, has been attracting attention. This control is an effective method for improving crop production. In the agricultural field, it is necessary to measure Photon Flux Density (PFD), which is an important parameter in the promotion of plant growth. In particular, the PFD of Photosynthetically Active Radiation (PAR, 400-700 nm) and Plant Biologically Active Radiation (PBAR, 300-800 nm) have been discussed in agricultural plant science. The commercial quantum meter (QM, PAR meter) can only measure Photosynthetically Photon Flux Density (PPFD) which is the integrated PFD quantity on the PAR wavelength. Inmore » this research, a band-spectral pyranometer or quantum meter using PVs with optical bandpass filters for dividing the PBAR wavelength into 100 nm bands (five independent channels) was developed. Before field testing, calibration of the instruments was carried out using a solar simulator. Next, a field test was conducted in three differing weather conditions such as clear, partly cloudy and cloudy skies. As a result, it was found that the response rate of the developed pyranometer was faster by four seconds compared with the response rate of the commercial pyranometer. Moreover, the outputs of each channel in the developed pyranometer were very similar to the integrated outputs of the commercial spectroradiometer. It was confirmed that the solar irradiance could be measured in each band separately using the developed band-spectral pyranometer. It was indicated that the developed band-spectral pyranometer could also be used as a PV band-spectral quantum meter which is obtained by converting the band irradiance into band PFD.« less

  3. Sedimentation Survey of Lago Patillas, Puerto Rico, March 2007

    USGS Publications Warehouse

    Soler-López, Luis R.

    2010-01-01

    Lago Patillas is a reservoir located on the confluence of Rio Grande de Patillas and Rio Marin, in the municipality of Patillas in southern Puerto Rico, about 3 kilometers north of the town of Patillas and about 8 kilometers northeast of the town of Arroyo (fig. 1). The dam is owned and operated by the Puerto Rico Electric Power Authority (PREPA) and was constructed in 1914 for the irrigation of croplands in the southern coastal plains of Puerto Rico along the towns of Arroyo, Guayama, Patillas, and Salinas. Irrigation releases are made through the outlet works into the Patillas Irrigation Canal that extends 32.2 kilometers from the Patillas dam to Rio Salinas. The dam is a semi-hydraulic earthfill with a structural height of 44.80 meters, a top width of 4.57 meters, a base width of 190.49 meters, and a crest length of 325.21 meters. The spillway structure is physically separated from the earthfill dam, has an elevation of 58.21 meters above mean sea level, and has three radial arm gates (Puerto Rico Electric Power Authority, 1979). The reservoir impounds the waters of the Rio Grande de Patillas and Rio Marin. The reservoir has a drainage area of 66.3 square kilometers. Additional information and operational procedures are listed in Soler-Lopez and others (1999). During March 14-15, 2007, the U.S. Geological Survey (USGS), Caribbean Water Science Center (CWSC), in cooperation with the PREPA conducted a bathymetric survey of Lago Patillas to update the reservoir storage capacity and update the reservoir sedimentation rate by comparing the 2007 bathymetric survey data with previous 1997 data. The purpose of this report is to update the reservoir storage capacity, sedimentation rates, and areas of substantial sediment accumulation since April 1997.

  4. Storage capacity and sedimentation trends of Lago Garzas, Puerto Rico, 1996-2007

    USGS Publications Warehouse

    Soler-Lopez, L.R.

    2012-01-01

    Lago Garzas is located in west-central Puerto Rico, about 3.5 kilometers southwest of the town of Adjuntas, in the confluence of the Río Vacas and three other unnamed tributaries (fig. 1). The dam is owned and operated by the Puerto Rico Electric Power Authority (PREPA), and was constructed in 1943 for hydroelectric power generation and municipal water use along the southern coast. The dam is a semi-hydraulic earthfill embankment lined with boulders, and has a height of 61.57 meters, a top width of 9.14 meters, a base width of 365.76 meters, and a crest length of 227.37 meters; State Road PR-518 crosses the top of the dam. A morning-glory-type spillway is located near the west abutment of the dam at an elevation of 736.12 meters above mean sea level (Puerto Rico Water Resources Authority, 1969). Figure 2 shows an aerial photograph of the Lago Garzas earthfill dam and the morning-glory spillway section. Additional information and operational procedures are provided in Soler-López and others (1999). During July 17-18, 2007, the U.S. Geological Survey (USGS) Caribbean Water Science Center, in cooperation with the Puerto Rico Aqueduct and Sewer Authority, conducted a bathymetric survey of Lago Garzas to update the reservoir storage capacity and update the reservoir sedimentation rate by comparing the 2007 data with the previous 1996 bathymetric survey results. The purpose of this report is to describe and document the USGS sedimentation survey conducted at Lago Garzas during July 2007, including the methods used to update the reservoir storage capacity, sedimentation rates, and areas of substantial sediment accumulation since 1996.

  5. BLOND, a building-level office environment dataset of typical electrical appliances.

    PubMed

    Kriechbaumer, Thomas; Jacobsen, Hans-Arno

    2018-03-27

    Energy metering has gained popularity as conventional meters are replaced by electronic smart meters that promise energy savings and higher comfort levels for occupants. Achieving these goals requires a deeper understanding of consumption patterns to reduce the energy footprint: load profile forecasting, power disaggregation, appliance identification, startup event detection, etc. Publicly available datasets are used to test, verify, and benchmark possible solutions to these problems. For this purpose, we present the BLOND dataset: continuous energy measurements of a typical office environment at high sampling rates with common appliances and load profiles. We provide voltage and current readings for aggregated circuits and matching fully-labeled ground truth data (individual appliance measurements). The dataset contains 53 appliances (16 classes) in a 3-phase power grid. BLOND-50 contains 213 days of measurements sampled at 50kSps (aggregate) and 6.4kSps (individual appliances). BLOND-250 consists of the same setup: 50 days, 250kSps (aggregate), 50kSps (individual appliances). These are the longest continuous measurements at such high sampling rates and fully-labeled ground truth we are aware of.

  6. BLOND, a building-level office environment dataset of typical electrical appliances

    NASA Astrophysics Data System (ADS)

    Kriechbaumer, Thomas; Jacobsen, Hans-Arno

    2018-03-01

    Energy metering has gained popularity as conventional meters are replaced by electronic smart meters that promise energy savings and higher comfort levels for occupants. Achieving these goals requires a deeper understanding of consumption patterns to reduce the energy footprint: load profile forecasting, power disaggregation, appliance identification, startup event detection, etc. Publicly available datasets are used to test, verify, and benchmark possible solutions to these problems. For this purpose, we present the BLOND dataset: continuous energy measurements of a typical office environment at high sampling rates with common appliances and load profiles. We provide voltage and current readings for aggregated circuits and matching fully-labeled ground truth data (individual appliance measurements). The dataset contains 53 appliances (16 classes) in a 3-phase power grid. BLOND-50 contains 213 days of measurements sampled at 50kSps (aggregate) and 6.4kSps (individual appliances). BLOND-250 consists of the same setup: 50 days, 250kSps (aggregate), 50kSps (individual appliances). These are the longest continuous measurements at such high sampling rates and fully-labeled ground truth we are aware of.

  7. BLOND, a building-level office environment dataset of typical electrical appliances

    PubMed Central

    Kriechbaumer, Thomas; Jacobsen, Hans-Arno

    2018-01-01

    Energy metering has gained popularity as conventional meters are replaced by electronic smart meters that promise energy savings and higher comfort levels for occupants. Achieving these goals requires a deeper understanding of consumption patterns to reduce the energy footprint: load profile forecasting, power disaggregation, appliance identification, startup event detection, etc. Publicly available datasets are used to test, verify, and benchmark possible solutions to these problems. For this purpose, we present the BLOND dataset: continuous energy measurements of a typical office environment at high sampling rates with common appliances and load profiles. We provide voltage and current readings for aggregated circuits and matching fully-labeled ground truth data (individual appliance measurements). The dataset contains 53 appliances (16 classes) in a 3-phase power grid. BLOND-50 contains 213 days of measurements sampled at 50kSps (aggregate) and 6.4kSps (individual appliances). BLOND-250 consists of the same setup: 50 days, 250kSps (aggregate), 50kSps (individual appliances). These are the longest continuous measurements at such high sampling rates and fully-labeled ground truth we are aware of. PMID:29583141

  8. Making The Most Of Flaring M Dwarfs

    NASA Astrophysics Data System (ADS)

    Hunt-Walker, Nicholas; Hilton, E.; Kowalski, A.; Hawley, S.; Matthews, J.; Holtzman, J.

    2011-01-01

    We present observations of flare activity using the Microvariability and Oscillations of Stars (MOST) satellite in conjunction with simultaneous spectroscopic and photometric observations from the ARC 3.5-meter, NMSU 1.0-meter, and ARCSAT 0.5-meter telescopes at the Apache Point Observatory. The MOST observations enable unprecedented completeness with regard to observing frequent, low-energy flares on the well-known dMe flare star AD Leo with broadband photometry. The observations span approximately one week with a 60-second cadence and are sensitive to flares as small as 0.01-magnitudes. The time-resolved, ground-based spectroscopy gives measurements of Hα and other important chromospheric emission lines, whereas the Johnson U-, SDSS u-, and SDSS g-band photometry provide color information during the flare events and allow us to relate the MOST observations to decades of previous broadband observations. Understanding the rates and energetics of flare events on M dwarfs will help characterize this source of variability in large time-domain surveys such as LSST and Pan-STARRS. Flare rates are also of interest to astrobiology, since flares affect the habitability of exoplanets orbiting M dwarfs.

  9. Aerocapture Performance Analysis of A Venus Exploration Mission

    NASA Technical Reports Server (NTRS)

    Starr, Brett R.; Westhelle, Carlos H.

    2005-01-01

    A performance analysis of a Discovery Class Venus Exploration Mission in which aerocapture is used to capture a spacecraft into a 300km polar orbit for a two year science mission has been conducted to quantify its performance. A preliminary performance assessment determined that a high heritage 70 sphere-cone rigid aeroshell with a 0.25 lift to drag ratio has adequate control authority to provide an entry flight path angle corridor large enough for the mission s aerocapture maneuver. A 114 kilograms per square meter ballistic coefficient reference vehicle was developed from the science requirements and the preliminary assessment s heating indicators and deceleration loads. Performance analyses were conducted for the reference vehicle and for sensitivity studies on vehicle ballistic coefficient and maximum bank rate. The performance analyses used a high fidelity flight simulation within a Monte Carlo executive to define the aerocapture heating environment and deceleration loads and to determine mission success statistics. The simulation utilized the Program to Optimize Simulated Trajectories (POST) that was modified to include Venus specific atmospheric and planet models, aerodynamic characteristics, and interplanetary trajectory models. In addition to Venus specific models, an autonomous guidance system, HYPAS, and a pseudo flight controller were incorporated in the simulation. The Monte Carlo analyses incorporated a reference set of approach trajectory delivery errors, aerodynamic uncertainties, and atmospheric density variations. The reference performance analysis determined the reference vehicle achieves 100% successful capture and has a 99.87% probability of attaining the science orbit with a 90 meters per second delta V budget for post aerocapture orbital adjustments. A ballistic coefficient trade study conducted with reference uncertainties determined that the 0.25 L/D vehicle can achieve 100% successful capture with a ballistic coefficient of 228 kilograms per square meter and that the increased ballistic coefficient increases post aerocapture V budget to 134 meters per second for a 99.87% probability of attaining the science orbit. A trade study on vehicle bank rate determined that the 0.25 L/D vehicle can achieve 100% successful capture when the maximum bank rate is decreased from 30 deg/s to 20 deg/s. The decreased bank rate increases post aerocapture delta V budget to 102 meters per second for a 99.87% probability of attaining the science orbit.

  10. A quality assurance program for clinical PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Finlay, Jarod; Ong, Yi Hong; Zhu, Timothy C.

    2018-02-01

    Successful outcome of Photodynamic therapy (PDT) depends on accurate delivery of prescribed light dose. A quality assurance program is necessary to ensure that light dosimetry is correctly measured. We have instituted a QA program that include examination of long term calibration uncertainty of isotropic detectors for light fluence rate, power meter head intercomparison for laser power, stability of the light-emitting diode (LED) light source integrating sphere as a light fluence standard, laser output and calibration of in-vivo reflective fluorescence and absorption spectrometers. We examined the long term calibration uncertainty of isotropic detector sensitivity, defined as fluence rate per voltage. We calibrate the detector using the known calibrated light fluence rate of the LED light source built into an internally baffled 4" integrating sphere. LED light sources were examined using a 1mm diameter isotropic detector calibrated in a collimated beam. Wavelengths varying from 632nm to 690nm were used. The internal LED method gives an overall calibration accuracy of +/- 4%. Intercomparison among power meters was performed to determine the consistency of laser power and light fluence rate measured among different power meters. Power and fluence readings were measured and compared among detectors. A comparison of power and fluence reading among several power heads shows long term consistency for power and light fluence rate calibration to within 3% regardless of wavelength. The standard LED light source is used to calibrate the transmission difference between different channels for the diffuse reflective absorption and fluorescence contact probe as well as isotropic detectors used in PDT dose dosimeter.

  11. Recovery to resting metabolic state after walking.

    PubMed

    Frankenfield, David C; Coleman, Abigail

    2009-11-01

    Metabolic rate is usually measured in a resting state. To achieve this, a period of up to 30 minutes is given to recover from walking prior to the test. A work group from the American Dietetic Association recommends that 10 to 20 minutes is sufficient to achieve rest, but supporting data are limited. The purpose of this prospective observational study then was to determine how much time is needed for adults to recover to rest after walking 300 meters. Each participant's metabolic rate was measured with indirect calorimetry for 30 minutes after a 30-minute rest. The participant then walked 300 meters on a measured course, and metabolic rate was measured again for 30 minutes. Recovery to rest was considered to have occurred when the measured metabolic rate returned to a level of less than 6% above the resting measurement. Forty healthy ambulatory adults completed this study. Analysis of variance indicated that after a 300-meter walk, resting level of metabolic rate was achieved by the 10th minute of rest. However, it took 20 minutes for 95% of all participants to meet the 6% threshold (the remaining 5% who did not reach the threshold were observed to be moving during the measurement). The results of this study indicate that if a person lies still, recovery to rest after walking occurs by 20 minutes, validating the recommendation made by the expert panel of the American Dietetic Association's work group on indirect calorimetry. Rest periods of 30 minutes are not required, but the person should be observed for movement.

  12. Hydraulic characteristics of an underdrained irrigation circle, Muskegon County, wastewater disposal system, Michigan

    USGS Publications Warehouse

    McDonald, M.G.

    1981-01-01

    Muskegon County, Michigan, disposes of waste water by spray irrigating farmland on its waste-disposal site. Buried drains in the highly permeable unconfined aquifer at the site control the level of the water table. Hydraulic conductivity of the aquifer and drain-leakance, the reciprocal of resistance to flow into the drains, was determined at a representative irrigation circle while calibrating a model of the ground-water flow system. Hydraulic conductivity is 0.00055 meter per second in the north zone of the circle and 0.00039 meter per second in the south zone. Drain leakance is low in both zones: 2.9 x 10-6 meters per second in the north and 9.5 x 10-6 meters per second in the south. Low drain leakance is responsible for waterlogging when irrigation rates are maintained at design levels. The capacity of the study circle to accept waste water is 35 percent less than design capacity.

  13. Response of six neutron survey meters in mixed fields of fast and thermal neutrons.

    PubMed

    Kim, S I; Kim, B H; Chang, I; Lee, J I; Kim, J L; Pradhan, A S

    2013-10-01

    Calibration neutron fields have been developed at KAERI (Korea Atomic Energy Research Institute) to study the responses of commonly used neutron survey meters in the presence of fast neutrons of energy around 10 MeV. The neutron fields were produced by using neutrons from the (241)Am-Be sources held in a graphite pile and a DT neutron generator. The spectral details and the ambient dose equivalent rates of the calibration fields were established, and the responses of six neutron survey meters were evaluated. Four single-moderator-based survey meters exhibited an under-responses ranging from ∼9 to 55 %. DINEUTRUN, commonly used in fields around nuclear reactors, exhibited an over-response by a factor of three in the thermal neutron field and an under-response of ∼85 % in the mixed fields. REM-500 (tissue-equivalent proportional counter) exhibited a response close to 1.0 in the fast neutron fields and an under-response of ∼50 % in the thermal neutron field.

  14. A comparison of selected models for estimating cable icing

    NASA Astrophysics Data System (ADS)

    McComber, Pierre; Druez, Jacques; Laflamme, Jean

    In many cold climate countries, it is becoming increasingly important to monitor transmission line icing. Indeed, by knowing in advance of localized danger for icing overloads, electric utilities can take measures in time to prevent generalized failure of the power transmission network. Recently in Canada, a study was made to compare the estimation of a few icing models working from meteorological data in estimating ice loads for freezing rain events. The models tested were using only standard meteorological parameters, i.e. wind speed and direction, temperature and precipitation rate. This study has shown that standard meteorological parameters can only achieve very limited accuracy, especially for longer icing events. However, with the help of an additional instrument monitoring the icing rate intensity, a significant improvement in model prediction might be achieved. The icing rate meter (IRM) which counts icing and de-icing cycles per unit time on a standard probe can be used to estimate the icing intensity. A cable icing estimation is then made by taking into consideration the accretion size, temperature, wind speed and direction, and precipitation rate. In this paper, a comparison is made between the predictions of two previously tested models (one obtained and the other reconstructed from their description in the public literature) and of a model based on the icing rate meter readings. The models are tested against nineteen events recorded on an icing test line at Mt. Valin, Canada, during the winter season 1991-1992. These events are mostly rime resulting from in-cloud icing. However, freezing rain and wet snow events were also recorded. Results indicate that a significant improvement in the estimation is attained by using the icing rate meter data together with the other standard meteorological parameters.

  15. Aesthetic and Emotional Effects of Meter and Rhyme in Poetry

    PubMed Central

    Obermeier, Christian; Menninghaus, Winfried; von Koppenfels, Martin; Raettig, Tim; Schmidt-Kassow, Maren; Otterbein, Sascha; Kotz, Sonja A.

    2013-01-01

    Metrical patterning and rhyme are frequently employed in poetry but also in infant-directed speech, play, rites, and festive events. Drawing on four line-stanzas from nineteenth and twentieth German poetry that feature end rhyme and regular meter, the present study tested the hypothesis that meter and rhyme have an impact on aesthetic liking, emotional involvement, and affective valence attributions. Hypotheses that postulate such effects have been advocated ever since ancient rhetoric and poetics, yet they have barely been empirically tested. More recently, in the field of cognitive poetics, these traditional assumptions have been readopted into a general cognitive framework. In the present experiment, we tested the influence of meter and rhyme as well as their interaction with lexicality in the aesthetic and emotional perception of poetry. Participants listened to stanzas that were systematically modified with regard to meter and rhyme and rated them. Both rhyme and regular meter led to enhanced aesthetic appreciation, higher intensity in processing, and more positively perceived and felt emotions, with the latter finding being mediated by lexicality. Together these findings clearly show that both features significantly contribute to the aesthetic and emotional perception of poetry and thus confirm assumptions about their impact put forward by cognitive poetics. The present results are explained within the theoretical framework of cognitive fluency, which links structural features of poetry with aesthetic and emotional appraisal. PMID:23386837

  16. Mass balance, meteorology, area altitude distribution, glacier-surface altitude, ice motion, terminus position, and runoff at Gulkana Glacier, Alaska, 1996 balance year

    USGS Publications Warehouse

    March, Rod S.

    2003-01-01

    The 1996 measured winter snow, maximum winter snow, net, and annual balances in the Gulkana Glacier Basin were evaluated on the basis of meteorological, hydrological, and glaciological data. Averaged over the glacier, the measured winter snow balance was 0.87 meter on April 18, 1996, 1.1 standard deviation below the long-term average; the maximum winter snow balance, 1.06 meters, was reached on May 28, 1996; and the net balance (from August 30, 1995, to August 24, 1996) was -0.53 meter, 0.53 standard deviation below the long-term average. The annual balance (October 1, 1995, to September 30, 1996) was -0.37 meter. Area-averaged balances were reported using both the 1967 and 1993 area altitude distributions (the numbers previously given in this abstract use the 1993 area altitude distribution). Net balance was about 25 percent less negative using the 1993 area altitude distribution than the 1967 distribution. Annual average air temperature was 0.9 degree Celsius warmer than that recorded with the analog sensor used since 1966. Total precipitation catch for the year was 0.78 meter, 0.8 standard deviations below normal. The annual average wind speed was 3.5 meters per second in the first year of measuring wind speed. Annual runoff averaged 1.50 meters over the basin, 1.0 standard deviation below the long-term average. Glacier-surface altitude and ice-motion changes measured at three index sites document seasonal ice-speed and glacier-thickness changes. Both showed a continuation of a slowing and thinning trend present in the 1990s. The glacier terminus and lower ablation area were defined for 1996 with a handheld Global Positioning System survey of 126 locations spread out over about 4 kilometers on the lower glacier margin. From 1949 to 1996, the terminus retreated about 1,650 meters for an average retreat rate of 35 meters per year.

  17. Comparison of liver fibrosis blood tests developed for HCV with new specific tests in HIV/HCV co-infection.

    PubMed

    Calès, Paul; Halfon, Philippe; Batisse, Dominique; Carrat, Fabrice; Perré, Philippe; Penaranda, Guillaume; Guyader, Dominique; d'Alteroche, Louis; Fouchard-Hubert, Isabelle; Michelet, Christian; Veillon, Pascal; Lambert, Jérôme; Weiss, Laurence; Salmon, Dominique; Cacoub, Patrice

    2010-08-01

    We compared 5 non-specific and 2 specific blood tests for liver fibrosis in HCV/HIV co-infection. Four hundred and sixty-seven patients were included into derivation (n=183) or validation (n=284) populations. Within these populations, the diagnostic target, significant fibrosis (Metavir F > or = 2), was found in 66% and 72% of the patients, respectively. Two new fibrosis tests, FibroMeter HICV and HICV test, were constructed in the derivation population. Unadjusted AUROCs in the derivation population were: APRI: 0.716, Fib-4: 0.722, Fibrotest: 0.778, Hepascore: 0.779, FibroMeter: 0.783, HICV test: 0.822, FibroMeter HICV: 0.828. AUROCs adjusted on classification and distribution of fibrosis stages in a reference population showed similar values in both populations. FibroMeter, FibroMeter HICV and HICV test had the highest correct classification rates in F0/1 and F3/4 (which account for high predictive values): 77-79% vs. 70-72% in the other tests (p=0.002). Reliable individual diagnosis based on predictive values > or = 90% distinguished three test categories: poorly reliable: Fib-4 (2.4% of patients), APRI (8.9%); moderately reliable: Fibrotest (25.4%), FibroMeter (26.6%), Hepascore (30.2%); acceptably reliable: HICV test (40.2%), FibroMeter HICV (45.6%) (p<10(-3) between tests). FibroMeter HICV classified all patients into four reliable diagnosis intervals (< or =F1, F1+/-1, > or =F1, > or =F2) with an overall accuracy of 93% vs. 79% (p<10(-3)) for a binary diagnosis of significant fibrosis. Tests designed for HCV infections are less effective in HIV/HCV infections. A specific test, like FibroMeter HICV, was the most interesting test for diagnostic accuracy, correct classification profile, and a reliable diagnosis. With reliable diagnosis intervals, liver biopsy can therefore be avoided in all patients. Copyright 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  18. Spin Rate Diversity Amongst Ten-meter Class Near Earth Asteroids

    NASA Astrophysics Data System (ADS)

    Ryan, William; Ryan, Eileen V.

    2016-10-01

    The spin rates of small asteroids can provide insight into their mechanical structure, origin, and subsequent evolution. This is of more than just scientific interest since these are also the objects that will hit the Earth most frequently. Early statistics [Pravec and Harris, 2000] for Near Earth Asteroids (NEAs) with diameters of ~100 meters or less had resulted in the conclusion that many are rotating more rapidly than feasible for a gravitationally bound system of constituent components (i.e, 'rubble piles'). However, more recent studies [Holsapple, 2007; Scheeres et al. 2010] have focused on how non-gravitational cohesion mechanisms do not necessarily rule out a rubble pile structure for fast spin rate bodies. To further study this issue, we will report on the recent spin rate results for the smallest asteroids observed as part of our ongoing NEA target-of-opportunity characterization research [Ryan and Ryan, 2016] conducted using the Magdalena Ridge Observatory's 2.4-meter telescope.Spin rates determined by this program plus results from the current lightcurve database [Warner et al. 2016] indicate that the very smallest NEAs with H>29 rotate with periods of minutes or less. This implies that these objects possess significant strength, hinting that they are likely examples of truly monolithic fragments. However, our observations also show a great diversity in rotation periods for asteroids that are only slightly larger. In particular, the H~28.6 asteroids 2016 CC136 and 2016 CG18 were observed to rotate with periods approaching or exceeding ~2 hours, with the latter showing a tumbling behavior. In a subset of our database that includes 22 asteroids with H~27.5 (~10 meters) or greater, a full range of periods from less than a minute to greater than 2 hours (close to the minimal period of a self-gravitating system), have been identified. Moreover, at least three of these are in a tumbling state with multiple periods clearly identified, implying constraints on their ages. The overall diversity in the observed spins in our database will be discussed in the context of better understanding internal body strengths required for the smallest asteroids.

  19. The Impacts of Changes to Nevada’s Net Metering Policy on the Financial Performance and Adoption of Distributed Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gagnon, Pieter; Sigrin, Ben; Gleason, Mike

    Net energy metering (NEM) is a billing mechanism that has historically compensated owners of distributed generation systems at retail rates for any electricity that they export back to the grid rather than consume on-site. NEM can significantly enhance the financial performance of distributed generation systems from the owner’s perspective. The following analysis was designed to illustrate the potential impact of NEM policy and tariff changes implemented in early 2016 in Nevada.

  20. Embedded computer controlled premixing inline injection system for air-assisted variable-rate sprayers

    USDA-ARS?s Scientific Manuscript database

    Improvements to reduce chemical waste and environmental pollution for variable-rate sprayers used in orchards and ornamental nurseries require inline injection techniques. A microprocessor controlled premixing inline injection system implementing a ceramic piston chemical metering pump and two small...

  1. Sedimentation Survey of Lago Guerrero, Puerto Rico, May 2001

    USGS Publications Warehouse

    Soler-López, Luis R.

    2002-01-01

    Lago Guerrero, a small reservoir owned by the Puerto Rico Electric Power Authority, is part of the Isabela Hydroelectric System and is located in Aguadilla, in northwestern Puerto Rico. The reservoir had a storage capacity of about 127,376 cubic meters in May 2001 and a maximum depth of about 5.8 meters. Records on dam construction and original topography and storage capacity were not available; therefore, sedimentation rates could not be determined. However, Lago Guerrero resumably was constructed during the 1930?s because it receives water from lago Guajataca, which was constructed in 1928. The May 2001 bathymetric survey of Lago Guerrero established baseline data that are essential to calculate sedimentation rates, sediment yields, storage loss, and sediment deposition sites within the reservoir.

  2. Towards metering tap water by Lorentz force velocimetry

    NASA Astrophysics Data System (ADS)

    Vasilyan, Suren; Ebert, Reschad; Weidner, Markus; Rivero, Michel; Halbedel, Bernd; Resagk, Christian; Fröhlich, Thomas

    2015-11-01

    In this paper, we present enhanced flow rate measurement by applying the contactless Lorentz Force Velocimetry (LFV) technique. Particularly, we show that the LFV is a feasible technique for metering the flow rate of salt water in a rectangular channel. The measurements of the Lorentz forces as a function of the flow rate are presented for different electrical conductivities of the salt water. The smallest value of conductivity is achieved at 0.06 S·m-1, which corresponds to the typical value of tap water. In comparison with previous results, the performance of LFV is improved by approximately 2 orders of magnitude by means of a high-precision differential force measurement setup. Furthermore, the sensitivity curve and the calibration factor of the flowmeter are provided based on extensive measurements for the flow velocities ranging from 0.2 to 2.5 m·s-1 and conductivities ranging from 0.06 to 10 S·m-1.

  3. Determination of land subsidence related to ground-water-level declines using Global Positioning System and leveling surveys in Antelope Valley, Los Angeles and Kern counties, California, 1992

    USGS Publications Warehouse

    Ikehara, M.E.; Phillips, S.P.

    1994-01-01

    A large-scale, land-subsidence monitoring network for Antelope Valley, California, was established, and positions and elevations for 85 stations were measured using Global Positioning System geodetic surveying in spring 1992. The 95-percent confidence (2@) level of accuracy for the elevations calculated for a multiple-constraint adjustment generally ranged from +0.010 meter (0.032 foot) to +0.024 meter (0.078 foot). The magnitudes and rates of land subsidence as of 1992 were calculated for several periods for 218 bench marks throughout Antelope Valley. The maximum measured magnitude of land subsidence that occurred between 1926 and 1992 was 6.0 feet (1.83 meters) at BM 474 near Avenue I and Sierra Highway. Measured or estimated subsidence of 2-7 feet (.61-2.l3 meters) had occurred in a 210- square-mile (542-square-kilometer) area of Antelope Valley, generally bounded by Avenue K, Avenue A, 90th Street West, and 120th Street East, during the same period. Land subsidence in Antelope Valley is caused by aquifer-system compaction, which is related to ground-water-level declines and the presence of fine-grained, compressible sediments. Comparison of potentiomethric-surface, water-level decline, and subsidence-rate maps for several periods indicated a general correlation between water-level declines and the distribution and rate of subsidence in the Lancaster ground-water subbasin. A conservative estimate of the amount of the reduction in storage capacity of the aquifer system in the Lancaster subbasin is about 50,000 acre-feet in the area that has been affected by more than one foot (.30 meters) of subsidence as of 1992. Information on the history of ground-water levels and the distribution and thickness of fine-grained compressible sediments can be used to mitigate continued land subsidence. Future monitoring of ground-water levels and land-surface elevations in subsidence-sensitive regions of Antelope Valley may be an effective means to manage land subsidence.

  4. Magma supply rate at kilauea volcano, 1952-1971.

    PubMed

    Swanson, D A

    1972-01-14

    The three longest Kilauea eruptions since 1952 produced lava at an overall constant rate of about 9 x 10(6) cubic meters per month (vesicle-free). This is considered to represent the rate of magma supply from a deep source, probably the mantle, because little or no summit deformation indicating high-level storage accompanied any of the three eruptions.

  5. 40 CFR 98.154 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the concentrations of the process samples. (b) The mass flow of the product stream containing the HFC... concentration and volumetric flow rate determined by measurement of volumetric flow rate using EPA Method 2, 2A... volumetric flow rate at the inlet or by a metering device for HFC-23 sent to the device. Determine a new...

  6. Closed-Loop Control of Chemical Injection Rate for a Direct Nozzle Injection System.

    PubMed

    Cai, Xiang; Walgenbach, Martin; Doerpmond, Malte; Schulze Lammers, Peter; Sun, Yurui

    2016-01-20

    To realize site-specific and variable-rate application of agricultural pesticides, accurately metering and controlling the chemical injection rate is necessary. This study presents a prototype of a direct nozzle injection system (DNIS) by which chemical concentration transport lag was greatly reduced. In this system, a rapid-reacting solenoid valve (RRV) was utilized for injecting chemicals, driven by a pulse-width modulation (PWM) signal at 100 Hz, so with varying pulse width the chemical injection rate could be adjusted. Meanwhile, a closed-loop control strategy, proportional-integral-derivative (PID) method, was applied for metering and stabilizing the chemical injection rate. In order to measure chemical flow rates and input them into the controller as a feedback in real-time, a thermodynamic flowmeter that was independent of chemical viscosity was used. Laboratory tests were conducted to assess the performance of DNIS and PID control strategy. Due to the nonlinear input-output characteristics of the RRV, a two-phase PID control process obtained better effects as compared with single PID control strategy. Test results also indicated that the set-point chemical flow rate could be achieved within less than 4 s, and the output stability was improved compared to the case without control strategy.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosio, J.; Wilcox, P.; Sembsmoen, O.

    A joint-venture, high-pressure, large-flow-rate facility to test, qualify, and research new natural-gas metering systems has been built by Den Norske Stats Oljeselskap A.S. (Statoil) and Total Marine Norsk A.S. Located near Haugesund in the Stavanger area, the lab, designated the Karsto Metering and Technology Laboratory, or K-Lab, is adjacent to Norway's first natural-gas-processing plant. It receives natural gas from across the Norwegian Trench from the Statfjord complex and after processing it sends it on to Emden, West Germany. The gas, which is produced in the North Sea, is transported to United Kingdom and the European continent through a high-pressure pipelinemore » network. The importance of gas-metering technology has been emphasized by oil and gas companies as well as by national regulatory authorities.« less

  8. Physicians' perception of alternative displays of clinical research evidence for clinical decision support - A study with case vignettes.

    PubMed

    Slager, Stacey L; Weir, Charlene R; Kim, Heejun; Mostafa, Javed; Del Fiol, Guilherme

    2017-07-01

    To design alternate information displays that present summaries of clinical trial results to clinicians to support decision-making; and to compare the displays according to efficacy and acceptability. A 6-between (information display presentation order) by 3-within (display type) factorial design. Two alternate displays were designed based on Information Foraging theory: a narrative summary that reduces the content to a few sentences; and a table format that structures the display according to the PICO (Population, Intervention, Comparison, Outcome) framework. The designs were compared with the summary display format available in PubMed. Physicians were asked to review five clinical studies retrieved for a case vignette; and were presented with the three display formats. Participants were asked to rate their experience with each of the information displays according to a Likert scale questionnaire. Twenty physicians completed the study. Overall, participants rated the table display more highly than either the text summary or PubMed's summary format (5.9vs. 5.4vs. 3.9 on a scale between 1 [strongly disagree] and 7 [strongly agree]). Usefulness ratings of seven pieces of information, i.e. patient population, patient age range, sample size, study arm, primary outcome, results of primary outcome, and conclusion, were high (average across all items=4.71 on a 1 to 5 scale, with 1=not at all useful and 5=very useful). Study arm, primary outcome, and conclusion scored the highest (4.9, 4.85, and 4.85 respectively). Participants suggested additional details such as rate of adverse effects. The table format reduced physicians' perceived cognitive effort when quickly reviewing clinical trial information and was more favorably received by physicians than the narrative summary or PubMed's summary format display. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Bilateral aniridia lenticular coloboma and snowflake retinal degeneration.

    PubMed

    Doganay, Selim; Emre, Sinan; Firat, Penpegül

    2009-01-01

    A 6-year-old boy presented with bilateral aniridia associated with lens coloboma and snowflake retinal degeneration. Ophthalmologic examination revealed bilateral corneal peripheral epithelial thickening and aniridia. Additionally, the patient had lenticular coloboma and snowflake retinal degeneration in both eyes. Intraocular pressure was 22 mm Hg bilaterally. The patient also had pendular nystagmus. Uncorrected visual acuity was counting fingers at 2 meters for both eyes, but improved to 0.2 and 0.05, respectively, with correction. Congenital aniridia has been reported with various ophthalmic pathologies, but this is the first case to display bilateral lenticular coloboma and snowflake retinal degeneration associated with aniridia.

  10. Fine Structure of a Laser-Plasma Filament in Air

    NASA Astrophysics Data System (ADS)

    Eisenmann, Shmuel; Pukhov, Anatoly; Zigler, Arie

    2007-04-01

    The ability to select and stabilize a single filament during propagation of an ultrashort high-intensity laser pulse in air makes it possible to examine the longitudinal structure of the plasma channel left in its wake. We present detailed measurements of plasma density variations along laser propagation. Over the length of the filament, electron density variations of 3 orders of magnitude are measured. They display evidence of a meter-long postionization range, along which a self-guided structure is observed coupled with a low plasma density, corresponding to ˜3 orders of magnitude decrease from the peak density level.

  11. Metabolic rate meter and method

    NASA Technical Reports Server (NTRS)

    Taylor, T. I.; Ruderman, I. W. (Inventor)

    1968-01-01

    A method is described for measuring the dynamic metabolic rate of a human or animal. The ratio of the exhaled carbon dioxide to a known amount of C(13)02 introduced into the exhalation is determined by mass spectrometry. This provides an instantaneous measurement of the carbon dioxide generated.

  12. 49 CFR 575.103 - Truck-camper loading.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... weight ratings and the longitudinal limits within which the center of gravity for the cargo weight rating.... (______ lbs.) of bottled gas, and ______ cubic meters (______ cubic ft.) refrigerator (or icebox with... recommends a cargo center of gravity zone that will contain the camper's center of gravity when it is...

  13. 49 CFR 575.103 - Truck-camper loading.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... weight ratings and the longitudinal limits within which the center of gravity for the cargo weight rating.... (______ lbs.) of bottled gas, and ______ cubic meters (______ cubic ft.) refrigerator (or icebox with... recommends a cargo center of gravity zone that will contain the camper's center of gravity when it is...

  14. 49 CFR 575.103 - Truck-camper loading.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... weight ratings and the longitudinal limits within which the center of gravity for the cargo weight rating.... (______ lbs.) of bottled gas, and ______ cubic meters (______ cubic ft.) refrigerator (or icebox with... recommends a cargo center of gravity zone that will contain the camper's center of gravity when it is...

  15. 49 CFR 575.103 - Truck-camper loading.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... weight ratings and the longitudinal limits within which the center of gravity for the cargo weight rating.... (______ lbs.) of bottled gas, and ______ cubic meters (______ cubic ft.) refrigerator (or icebox with... recommends a cargo center of gravity zone that will contain the camper's center of gravity when it is...

  16. 49 CFR 575.103 - Truck-camper loading.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... weight ratings and the longitudinal limits within which the center of gravity for the cargo weight rating.... (______ lbs.) of bottled gas, and ______ cubic meters (______ cubic ft.) refrigerator (or icebox with... recommends a cargo center of gravity zone that will contain the camper's center of gravity when it is...

  17. Behaviour of one-step spray-coated carbon nanotube supercapacitor in ambient light harvester circuit with printed organic solar cell and electrochromic display.

    PubMed

    Tuukkanen, Sampo; Välimäki, Marja; Lehtimäki, Suvi; Vuorinen, Tiina; Lupo, Donald

    2016-03-09

    A printed energy harvesting and storage circuit powered by ambient office lighting and its use to power a printed display is reported. The autonomous device is composed of three printed electronic components: an organic photovoltaic module, a carbon-nanotubes-only supercapacitor and an electrochromic display element. Components are fabricated from safe and environmentally friendly materials, and have been fabricated using solution processing methods, which translate into low-cost and high-throughput manufacturing. A supercapacitor made of spray-coated carbon nanotube based ink and aqueous NaCl electrolyte was charged using a printed organic photovoltaic module exposed to office lighting conditions. The supercapacitor charging rate, self-discharge rate and display operation were studied in detail. The supercapacitor self-discharge rate was found to depend on the charging rate. The fully charged supercapacitor was used as a power source to run the electrochromic display over 50 times.

  18. Mobile platform of altitude measurement based on a smartphone

    NASA Astrophysics Data System (ADS)

    Roszkowski, Paweł; Kowalczyk, Marcin

    2016-09-01

    The article presents a low cost, fully - functional meter of altitude and pressure changes in a form of mobile application controlled by Android OS (operating system). The measurements are possible due to pressure sensor inserted in majority of latest modern mobile phones, which are known as smartphones. Using their computing capabilities and other equipment components like GPS receiver in connection with data from the sensor enabled authors to create a sophisticated handheld measuring platform with many unique features. One of them is a drawing altitude maps mode in which user can create maps of altitude changes just by moving around examined area. Another one is a convenient mode for altitude measurement. It is also extended with analysis tools which provide a possibility to compare measured values by displaying the data in a form of plots. The platform consists of external backup server, where the user can secure all gathered data. Moreover, the results of measurement's accuracy examination process which was executed after building the solution were shown. At the end, the realized meter of altitude was compared to other popular altimeters, which are available on the market currently.

  19. Focused Heavy Ion Nuclear Microprobe facility at the University of North Texas

    NASA Astrophysics Data System (ADS)

    Guo, B. N.; Yang, C.; El Bouanani, M.; Duggan, J. L.; McDaniel, F. D.

    1999-10-01

    A Focused Heavy Ion Nuclear Microprobe facility has been constructed at the University of North Texas. The microprobe utilizes two separated Russian magnetic quadrupole quadruplets. The two identical magnetic quadrupole doublet lenses are separated by 2.61 meters. The lens system with ~ 80 times demagnification has the ability to focus proton, alpha particle, or heavier ions down to a spot size of ~ 1 μm. The microprobe components rest on a 7 meter steel beam support with vibration isolation. A computer provides control for the lens power supplies and also the parameters for a post-lens scanning coil to raster-scan the beam across the sample. Up to four detection channels can be used for simultaneous data acquisition under VME control. A RISC workstation is used to collect, display and analyze the data. The data is transferred via ethernet. A detailed description of the facility and data acquisition system along with preliminary testing results on TEM grids with Rutherford Backscattering Spectrometry and the Ion Beam Induced Charge Collection techniques will be presented.

  20. 24 CFR 241.560 - Agreed interest rate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SUPPLEMENTARY FINANCING FOR INSURED PROJECT MORTGAGES Eligibility Requirements-Supplemental Loans To Finance... Meters in Multifamily Projects Without a HUD-Insured or HUD-Held Mortgage Eligible Security Instruments...

  1. Collisional Tectonics of the Saint Elias Orogen, Alaska, Observed by GPS

    NASA Astrophysics Data System (ADS)

    Elliott, J. L.; Freymueller, J. T.; Larsen, C. F.

    2005-12-01

    The Saint Elias orogen of south central Alaska and the adjacent area of Canada is the highest coastal mountain range on earth, with peaks that exceed 6000 meters in elevation. It is located in the complex transition zone between transform motion along the Queen Charlotte-Fairweather fault system and subduction along the Aleutian Megathrust. The Yakutat terrane lies in the gap between the end of the Megathrust and the end of the transform system. Roughly 4 cm/yr of convergence is accommodated within the continental crust, onshore and possibly offshore, as the Yakutat terrane collides with southern Alaska. This collision provides the driving force behind the stunning topographic relief of the orogen. As part of the STEEP project designed to unravel the tectonic complexities of this region, we made GPS measurements at 47 sites in south central Alaska during the summer of 2005. Here we present results from 13 campaign GPS sites that had prior measurements. The span of measurements at these campaign sites range from one to twelve years. All of the sites show northwestward motion and uplift. The highest amounts of uplift occur at several coastal sites near Icy Bay where average rates surpass 24 mm/yr. Further north, sites along the Bagley Icefield display an average uplift rate of about 20 mm/yr. A significant portion of this uplift is caused by the melting of regional icefields and the redistribution of mass in large glacier systems such as the Bering Glacier. We also examine the impact of the Denali Fault earthquake on the rates of motion in this area.

  2. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carroll, D.M.

    Pacific Northwest Laboratory developed this report for the US Navy`s Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC tomore » monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.« less

  3. Naval Undersea Warfare Center Division Newport utilities metering, Phase 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carroll, D.M.

    Pacific Northwest Laboratory developed this report for the US Navy's Naval Undersea Warfare Center Division Newport, Rhode Island (NUWC). The purpose of the report was to review options for metering electricity and steam used in the NUWC compound, and to make recommendations to NUWC for implementation under a follow-on project. An additional NUWC concern is a proposed rate change by the servicing utility, Newport Electric, which would make a significant shift from consumption to demand billing, and what effect that rate change would have on the NUWC utility budget. Automated, remote reading meters are available which would allow NUWC tomore » monitor its actual utility consumption and demand for both the entire NUWC compound and by end-use in individual buildings. Technology is available to perform the meter reads and manipulate the data using a personal computer with minimal staff requirement. This is not meant to mislead the reader into assuming that there is no requirement for routine preventive maintenance. All equipment requires routine maintenance to maintain its accuracy. While PNL reviewed the data collected during the site visit, however, it became obvious that significant opportunities exist for reducing the utility costs other than accounting for actual consumption and demand. Unit costs for both steam and electricity are unnecessarily high, and options are presented in this report for reducing them. Additionally, NUWC has an opportunity to undertake a comprehensive energy resource management program to significantly reduce its energy demand, consumption, and costs.« less

  4. Calibration and use of continuous heat-type automated seepage meters for submarine groundwater discharge measurements

    USGS Publications Warehouse

    Mwashote, B.M.; Burnett, W.C.; Chanton, J.; Santos, I.R.; Dimova, N.; Swarzenski, P.W.

    2010-01-01

    Submarine groundwater discharge (SGD) assessments were conducted both in the laboratory and at a field site in the northeastern Gulf of Mexico, using a continuous heat-type automated seepage meter (seepmeter). The functioning of the seepmeter is based on measurements of a temperature gradient in the water between downstream and upstream positions in its flow pipe. The device has the potential of providing long-term, high-resolution measurements of SGD. Using a simple inexpensive laboratory set-up, we have shown that connecting an extension cable to the seepmeter has a negligible effect on its measuring capability. Similarly, the observed influence of very low temperature (???3 ??C) on seepmeter measurements can be accounted for by conducting calibrations at such temperatures prior to field deployments. Compared to manual volumetric measurements, calibration experiments showed that at higher water flow rates (>28 cm day-1 or cm3 cm-2 day-1) an analog flowmeter overestimated flow rates by ???7%. This was apparently due to flow resistance, turbulence and formation of air bubbles in the seepmeter water flow tubes. Salinity had no significant effect on the performance of the seepmeter. Calibration results from fresh water and sea water showed close agreement at a 95% confidence level significance between the data sets from the two media (R2 = 0.98). Comparatively, the seepmeter SGD measurements provided data that are comparable to manually-operated seepage meters, the radon geochemical tracer approach, and an electromagnetic (EM) seepage meter. ?? 2009 Elsevier Ltd.

  5. Sedimentation survey of Lago de Matrullas, Puerto Rico, December 2001

    USGS Publications Warehouse

    Soler-López, Luis R.

    2003-01-01

    Lago de Matrullas reservoir, constructed in 1934, is located at an altitude of approximately 730 meters above mean sea level in the municipality of Orocovis in central Puerto Rico, and has a drainage area of 11.45 square kilometers. The reservoir is part of the Puerto Rico Electric Power Authority Toro Negro Hydroelectric Project, which also includes the Lago El Guineo reservoir and a hydroelectric plant to the south of the insular hydrographic divide. Historically, the drainage area had been protected from soil erosion by dense vegetation and the lack of basin development. However, transportation, potable water, and electric power infrastructure construction has facilitated development in rural areas resulting in the clearing of land. This trend in land-use changes is impacting the useful life of Lago de Matrullas. The reservoir storage capacity has been reduced from 3.71 million cubic meters in 1934 to 3.08 million cubic meters in 2001. This represents a total storage-capacity loss of 0.63 million cubic meters by 2001 (17 percent), or a long-term annual storage loss of 0.25 percent per year. The sediment trapping efficiency of Lago de Matrullas has been estimated at approximately 90 percent. If the current long-term sedimentation rate continues, Lago de Matrullas would fill by the year 2328. However, this life expectancy could be reduced at a faster than predicted rate as a result of rural development in the Lago de Matrullas basin and the high sediment trapping efficiency of the reservoir.

  6. Antecedents and consequences of emotional display rule perceptions.

    PubMed

    Diefendorff, James M; Richard, Erin M

    2003-04-01

    Central to all theories of emotional labor is the idea that individuals follow emotional display rules that specify the appropriate expression of emotions on the job. This investigation examined antecedents and consequences of emotional display rule perceptions. Full-time working adults (N = 152) from a variety of occupations provided self-report data, and supervisors and coworkers completed measures pertaining to the focal employees. Results using structural equation modeling revealed that job-based interpersonal requirements, supervisor display rule perceptions, and employee extraversion and neuroticism were predictive of employee display rule perceptions. Employee display rule perceptions, in turn, were related to self-reported job satisfaction and coworker ratings of employees' emotional displays on the job. Finally, neuroticism had direct negative relationships with job satisfaction and coworker ratings of employees' emotional displays.

  7. Biogeochemistry of Stinking Springs, Utah. Part II: Microbial Diversity and Photo- and Chemo-Autotrophic Growth Rates in a Layered Microbial Mat

    NASA Astrophysics Data System (ADS)

    Monteverde, D.; Metzger, J. G.; Bournod, C.; Kelly, H.; Johnson, H.; Sessions, A. L.; Osburn, M.; Shapiro, R. S.; Rideout, J.; Johnston, D. T.; Stevenson, B.; Stamps, B. W.; Vuono, D.; Hanselmann, K.; Spear, J. R.

    2013-12-01

    Layered microbial mats have garnered attention for their high phylogenetic diversity and exploitation of geochemical gradients often on the mm scale. However, despite their novelty and implications for early life diversification, little is known about layered microbial mat growth rates or the interdependence of the microbial communities within the system. Stinking Springs, a warm, sulfidic, saline spring northeast of the Great Salt Lake, serves as our test-site to investigate some of these questions. Stinking Springs undergoes downstream changes in pH (6.59-8.14), sulfide (527μM - below detection), sulfate (13-600μM), TCO2 (7.77-3.71mM), and temperature (40-21°C) along its ~150m flow path. The first 10m of discharge is channelized, beyond that, the spring supports a 10 to 40mm-thick layered microbial mat covering ~40% of the total spring runoff area. The mat was divided into four texturally-distinct layers which were each analyzed for 16S rRNA, lipid abundance, and bicarbonate and acetate uptake rates in addition to standard microscopy analyses. 16S rRNA analyses confirmed high taxa diversity within each layer, which varied significantly in taxa makeup such that no single phylum dominated the abundance (>33%) in more than one mat layer. The taxonomic diversity tended to increase with mat depth, a similar finding to other studies on layered microbial mats. A mat sampling transect across 16 meters showed that layer taxonomic diversity was conserved horizontally for all four mat layers, which implies mat depth has a larger control on diversity than physical or chemical parameters. Microscopy indicated the presence of diatoms in all layers which was confirmed by lipid abundance of sterols and long-branch fatty acid methyl esters. Incubation experiments were conducted in light and dark conditions over 24 hours with separate 13C-tagged bicarbonate and acetate additions. Heterotrophic growth rates (acetate uptake; 0.03-0.65%/day) were higher than autotrophic growth rates (bicarbonate uptake; 0-0.16%/day) under both dark and light conditions. Light conditions yielded higher growth rates for both heterotrophs and autotrophs and the highest rates were consistently found in the top mat layer and decreased with depth. The addition of 13C-acetate and concomitant high uptake is a measure of potential heterotrophy since in situ acetate concentrations are unlikely to be as high. 13C-bicarbonate uptake, on the other hand, should quantitatively represent the autotrophic growth rate. The Stinking Spring layered microbial mats display high taxonomic diversity, which is conserved horizontally across distances of meters and varies significantly with depth. Mats experience highest growth in the surface layer likely driven by phototrophs; high rates of bicarbonate uptake in the dark indicate considerable chemoautotrophy. Covariation in the heterotroph growth rates and 16S rRNA heterotroph abundance with mat depth indicates that heterotrophy may play an important role in the growth of these layered mats.

  8. Experimental Studies of the Effect of Intent Information on Cockpit Traffic Displays

    NASA Technical Reports Server (NTRS)

    Barhydt, Richard; Hansman, R. John

    1997-01-01

    Intent information provides knowledge of another aircraft's current and future trajectory states. Prototype traffic displays were designed for four different levels of intent: Position, Rate, Commanded State, and FMS (Flight Management System)-Path. The current TCAS (traffic collision avoidance systems) Display, which shows altitude rate in addition to current position and altitude, was used as a baseline and represents the lowest level of intent. The Rate, Commanded State, and FMS-Path Displays show increasing levels of intent information using TCAS-like symbology in addition to incorporating a conflict probe and profile view display. An initial experiment was run on the MIT (Massachusetts Institute of Technology) Part Task Flight Simulator in which eight airline pilots flew five traffic scenarios with each of the four displays. Results show that pilots had fewer separation violations and maneuvered earlier with the three intent displays. Separation violations were reduced when pilots maneuvered earlier. A second experiment was run to compare performance between displaying intent information directly and incorporating it into a conflict probe. A different set of eight airline pilots flew four traffic scenarios with the TCAS and Commanded State Displays with and without the conflict probe. Conflict probes with two minute and long range look-ahead times were tested. Displaying conflict bands or showing intent information directly both led to fewer separation violations and earlier avoidance maneuvers than the base TCAS Display. Performance was similar between the two minute and long range look-ahead conflict probes. Pilots preferred all intent displays over the TCAS Display.

  9. Crater Morphology of Engineered and Natural Impactors into Planetary Ice

    NASA Astrophysics Data System (ADS)

    Danner, M.; Winglee, R.; Koch, J.

    2017-12-01

    Crater morphology of engineered impactors, such as those proposed for the Europa Kinetic Ice Penetrator (EKIP) mission, varies drastically from that of natural impactors (i.e. Asteroids, meteoroids). Previous work of natural impact craters in ice have been conducted with the intent to bound the thickness of Europa's ice crust; this work focuses on the depth, size, and compressional effects caused by various impactor designs, and the possible effects to the Europan surface. The present work details results from nine projectiles that were dropped on the Taku Glacier, AK at an altitude of 775 meters above surface; three rocks to simulate natural impactors, and six iterations of engineered steel and aluminum penetrator projectiles. Density measurements were taken at various locations within the craters, as well as through a cross section of the crater. Due to altitude restrictions, projectiles remained below terminal velocity. The natural/rock impact craters displayed typical cratering characteristics such as shallow, half meter scale depth, and orthogonal compressional forcing. The engineered projectiles produced impact craters with depths averaging two meters, with crater widths matching the impactor diameters. Compressional waves from the engineered impactors propagated downwards, parallel to direction of impact. Engineered impactors create significantly less lateral fracturing than natural impactors. Due to the EKIP landing mechanism, sampling of pristine ice closer to the lander is possible than previously thought with classical impact theory. Future work is planned to penetrate older, multiyear ice with higher velocity impacts.

  10. Spatiotemporal evolution of a transient slip event on the San Andreas fault near Parkfield, California

    USGS Publications Warehouse

    Murray, J.R.; Segall, P.

    2005-01-01

    In 1993 several baselines of the two-color electronic distance meter (EDM) network at Parkfield, California, deviated from their long-term rates, coincident with anomalous observations from nearby strain meters and a creep meter, as well as an increase in microseismicity. Between October 1992 and December 1994, three M ??? 4.5 earthquakes occurred beneath Middle Mountain, near the hypocenter of the 1934 and 1966 Parkfield M6 events. We analyzed the two-color EDM data using a Kalman-filtering based technique to image the spatiotemporal evolution of slip on the fault at Parkfield between the mid-1980s and 2003. This method accounts for localized random walk motion of the geodetic monuments and a prominent seasonal signal that affects many baselines. We find that a slip rate increase occurred between January 1993 and July 1996 on the upper 8 km of the fault near Middle Mountain. The peak estimated slip rate during this time was 49 mm/yr, which exceeds the long-term geologic rate of ???35 mm/yr. The slip rate evolution appears episodic, with an initial modest increase after the M4.3 earthquake and a much larger jump following the shallower M4.7 event in December 1994. This temporal correlation between inferred slip and seismicity suggests that the moderate earthquakes triggered the aseismic fault slip. The EDM data cannot resolve whether transient slip propagated across the nucleation zone of the 1934 and 1966 M6 Parkfield earthquakes. However, transient slip and its associated stress release in the hypocentral area of previous Parkfield events is consistent with the nucleation of the 2004 M6 Parkfield earthquake elsewhere on the fault. Copyright 2005 by the American Geophysical Union.

  11. Field calibration of orifice meters for natural gas flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ting, V.C.; Shen, J.J.S.

    1989-03-01

    This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6,4,2-in.) orifice meters conducted at the Chevron's Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27{sup 0}C (650 psig and 80{sup 0}F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibratemore » the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron's high Reynolds number test data taken at a large test facility in Venice, Louisiana. The test results also successfully demonstrate that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.« less

  12. Ground Motion Analysis of Co-Located DAS and Seismometer Sensors

    NASA Astrophysics Data System (ADS)

    Wang, H. F.; Fratta, D.; Lord, N. E.; Lancelle, C.; Thurber, C. H.; Zeng, X.; Parker, L.; Chalari, A.; Miller, D.; Feigl, K. L.; Team, P.

    2016-12-01

    The PoroTomo research team deployed 8700-meters of Distributed Acoustic Sensing (DAS) cable in a shallow trench and 400-meters in a borehole at Brady Hot Springs, Nevada in March 2016 together with an array of 246, three-component geophones. The seismic sensors occupied a natural laboratory 1500 x 500 x 400 meters overlying the Brady geothermal field. The DAS cable was laid out in three parallel zig-zag lines with line segments approximately 100-meters in length and geophones were spaced at approximately 50-m intervals. In several line segments, geophones were co-located within one meter of the DAS cable. Both DAS and the conventional geophones recorded continuously over 15 days. A large Vibroseis truck (T-Rex) provided the seismic source at approximately 250 locations outside and within the array. The Vibroseis protocol called for excitation in one vertical and two orthogonal horizontal directions at each location. For each mode, three, 5-to-80-Hz upsweeps were made over 20 seconds. In addition, a moderate-sized earthquake with a local magnitude of 4.3 was recorded on March 21, 2016. Its epicenter was approximately 150-km away. Several DAS line segments with co-located geophone stations were used to test relationships between the strain rate recorded by DAS and ground velocity recorded by the geophones.

  13. A single blood test adjusted for different liver fibrosis targets improves fibrosis staging and especially cirrhosis diagnosis.

    PubMed

    Calès, Paul; Boursier, Jérôme; Oberti, Frédéric; Moal, Valérie; Fouchard Hubert, Isabelle; Bertrais, Sandrine; Hunault, Gilles; Rousselet, Marie Christine

    2018-04-01

    Fibrosis blood tests are usually developed using significant fibrosis, which is a unique diagnostic target; however, these tests are employed for other diagnostic targets, such as cirrhosis. We aimed to improve fibrosis staging accuracy by simultaneously targeting biomarkers for several diagnostic targets. A total of 3,809 patients were included, comprising 1,012 individuals with chronic hepatitis C (CHC) into a derivation population and 2,797 individuals into validation populations of different etiologies (CHC, chronic hepatitis B, human immunodeficiency virus/CHC, nonalcoholic fatty liver disease, alcohol) using Metavir fibrosis stages as reference. FibroMeter biomarkers were targeted for different fibrosis-stage combinations into classical scores by logistic regression. Independent scores were combined into a single score reflecting Metavir stages by linear regression and called Multi-FibroMeter Version Second Generation (V2G). The primary objective was to combine the advantages of a test targeted for significant fibrosis (FibroMeter V2G ) with those of a test targeted for cirrhosis (CirrhoMeter V2G ). In the derivation CHC population, we first compared Multi-FibroMeter V2G to FibroMeter V2G and observed significant increases in the cirrhosis area under the receiver operating characteristic curve (AUROC), Obuchowski index (reflecting all fibrosis-stage AUROCs), and classification metric (six classes expressed as a correctly classified percentage) and a nonsignificant increase in significant fibrosis AUROC. Thereafter, we compared it to CirroMeter V2G and observed a nonsignificant increase in the cirrhosis AUROC. In all 3,809 patients, respective accuracies for Multi-FibroMeter V2G and FibroMeter V2G were the following: cirrhosis AUROC, 0.906 versus 0.878 ( P < 0.001; versus CirroMeter V2G , 0.897, P = 0.014); Obuchowski index, 0.795 versus 0.791 ( P = 0.059); classification, 86.0% versus 82.1% ( P < 0.001); significant fibrosis AUROC, 0.833 versus 0.832 ( P = 0.366). Multi-FibroMeter V2G had the highest correlation with the area of portoseptal fibrosis and the highest reproducibility over time. Correct classification rates of Multi-FibroMeter with hyaluronate (V2G, 86.0%) or without (V3G, 86.1%) did not differ ( P = 0.938). Conclusion: Multitargeting biomarkers significantly improves fibrosis staging and especially cirrhosis diagnosis compared to classical single-targeted blood tests. ( Hepatology Communications 2018;2:455-466).

  14. A single blood test adjusted for different liver fibrosis targets improves fibrosis staging and especially cirrhosis diagnosis

    PubMed Central

    Boursier, Jérôme; Oberti, Frédéric; Moal, Valérie; Fouchard Hubert, Isabelle; Bertrais, Sandrine; Hunault, Gilles; Rousselet, Marie Christine

    2018-01-01

    Fibrosis blood tests are usually developed using significant fibrosis, which is a unique diagnostic target; however, these tests are employed for other diagnostic targets, such as cirrhosis. We aimed to improve fibrosis staging accuracy by simultaneously targeting biomarkers for several diagnostic targets. A total of 3,809 patients were included, comprising 1,012 individuals with chronic hepatitis C (CHC) into a derivation population and 2,797 individuals into validation populations of different etiologies (CHC, chronic hepatitis B, human immunodeficiency virus/CHC, nonalcoholic fatty liver disease, alcohol) using Metavir fibrosis stages as reference. FibroMeter biomarkers were targeted for different fibrosis‐stage combinations into classical scores by logistic regression. Independent scores were combined into a single score reflecting Metavir stages by linear regression and called Multi‐FibroMeter Version Second Generation (V2G). The primary objective was to combine the advantages of a test targeted for significant fibrosis (FibroMeterV2G) with those of a test targeted for cirrhosis (CirrhoMeterV2G). In the derivation CHC population, we first compared Multi‐FibroMeterV2G to FibroMeterV2G and observed significant increases in the cirrhosis area under the receiver operating characteristic curve (AUROC), Obuchowski index (reflecting all fibrosis‐stage AUROCs), and classification metric (six classes expressed as a correctly classified percentage) and a nonsignificant increase in significant fibrosis AUROC. Thereafter, we compared it to CirroMeterV2G and observed a nonsignificant increase in the cirrhosis AUROC. In all 3,809 patients, respective accuracies for Multi‐FibroMeterV2G and FibroMeterV2G were the following: cirrhosis AUROC, 0.906 versus 0.878 (P < 0.001; versus CirroMeterV2G, 0.897, P = 0.014); Obuchowski index, 0.795 versus 0.791 (P = 0.059); classification, 86.0% versus 82.1% (P < 0.001); significant fibrosis AUROC, 0.833 versus 0.832 (P = 0.366). Multi‐FibroMeterV2G had the highest correlation with the area of portoseptal fibrosis and the highest reproducibility over time. Correct classification rates of Multi‐FibroMeter with hyaluronate (V2G, 86.0%) or without (V3G, 86.1%) did not differ (P = 0.938). Conclusion: Multitargeting biomarkers significantly improves fibrosis staging and especially cirrhosis diagnosis compared to classical single‐targeted blood tests. (Hepatology Communications 2018;2:455‐466) PMID:29619423

  15. Real-Tme Boron Nitride Erosion Measurements of the HiVHAc Thruster via Cavity Ring-Down Spectroscopy

    NASA Technical Reports Server (NTRS)

    Lee, Brian C.; Yalin, Azer P.; Gallimore, Alec; Huang, Wensheng; Kamhawi, Hani

    2013-01-01

    Cavity ring-down spectroscopy was used to make real-time erosion measurements from the NASA High Voltage Hall Accelerator thruster. The optical sensor uses 250 nm light to measure absorption of atomic boron in the plume of an operating Hall thruster. Theerosion rate of the High Voltage Hall Accelerator thruster was measured for discharge voltages ranging from 330 to 600 V and discharge powers ranging from 1 to 3 kW. Boron densities as high as 6.5 x 10(exp 15) per cubic meter were found within the channel. Using a very simple boronvelocity model, approximate volumetric erosion rates between 5.0 x 10(exp -12) and 8.2 x 10(exp -12) cubic meter per second were found.

  16. The microprocessor-based synthesizer controller

    NASA Technical Reports Server (NTRS)

    Wick, M. R.

    1980-01-01

    Implementation and performance of the microprocessor-based controllers and Dana Digiphase Synthesizer (DCO) installed in the Deep Space Network exciter in the 64-meter and 34-meter subnets to support uplink tuning required for the Voyager-Saturn Encounter is discussed. Test data in tests conducted during the production of the controllers verified the design objective for phase control accuracy of 10 to the - 12 power cycles in eight hours during ramping. Tests conducted require a phase error between a theoretical calculated value and the actual phase of no greater than + or - 1 cycle. Tests included (1) a ramp over a period of eight hours using a ramp rate which covers the synthesizer tuning range (40-51 MHz) and (2) a ramp sequence using the maximum rate (+ or kHz/s) over the tuning range.

  17. Analysis of Electric Vehicle DC High Current Conversion Technology

    NASA Astrophysics Data System (ADS)

    Yang, Jing; Bai, Jing-fen; Lin, Fan-tao; Lu, Da

    2017-05-01

    Based on the background of electric vehicles, it is elaborated the necessity about electric energy accurate metering of electric vehicle power batteries, and it is analyzed about the charging and discharging characteristics of power batteries. It is needed a DC large current converter to realize accurate calibration of power batteries electric energy metering. Several kinds of measuring methods are analyzed based on shunts and magnetic induction principle in detail. It is put forward power batteries charge and discharge calibration system principle, and it is simulated and analyzed ripple waves containing rate and harmonic waves containing rate of power batteries AC side and DC side. It is put forward suitable DC large current measurement methods of power batteries by comparing different measurement principles and it is looked forward the DC large current measurement techniques.

  18. Evaluation of a turbine flow meter (Ventilometer Mark 2) in the measurement of ventilation.

    PubMed

    Cooper, C B; Harris, N D; Howard, P

    1990-01-01

    We have evaluated a turbine flow meter (Ventilometer Mark 2, PK Morgan, Kent, UK) at low flow rates and levels of ventilation which are likely to be encountered during exercise in patients with chronic respiratory disease. Pulsatile flows were generated from a volume-cycled mechanical ventilator, the flow wave-form was modified by damping to simulate a human breathing pattern. Comparative measurements of ventilation were made whilst varying tidal volume (VT) from 0.22 to 1.131 and respiratory rate (fR) from 10 to 35 min-1. At lower levels of ventilation the instrument tended to underread especially with increasing fR. The calibration factor must be adjusted to match the level of ventilation if the measurement errors are to be within 5%.

  19. Controlling motion sickness and spatial disorientation and enhancing vestibular rehabilitation with a user-worn see-through display.

    PubMed

    Krueger, Wesley W O

    2011-01-01

    An eyewear mounted visual display ("User-worn see-through display") projecting an artificial horizon aligned with the user's head and body position in space can prevent or lessen motion sickness in susceptible individuals when in a motion provocative environment as well as aid patients undergoing vestibular rehabilitation. In this project, a wearable display device, including software technology and hardware, was developed and a phase I feasibility study and phase II clinical trial for safety and efficacy were performed. Both phase I and phase II were prospective studies funded by the NIH. The phase II study used repeated measures for motion intolerant subjects and a randomized control group (display device/no display device) pre-posttest design for patients in vestibular rehabilitation. Following technology and display device development, 75 patients were evaluated by test and rating scales in the phase II study; 25 subjects with motion intolerance used the technology in the display device in provocative environments and completed subjective rating scales, whereas 50 patients were evaluated before and after vestibular rehabilitation (25 using the display device and 25 in a control group) using established test measures. All patients with motion intolerance rated the technology as helpful for nine symptoms assessed, and 96% rated the display device as simple and easy to use. Duration of symptoms significantly decreased with use of the technology displayed. In patients undergoing vestibular rehabilitation, there were no significant differences in amount of change from pre- to posttherapy on objective balance tests between display device users and controls. However, those using the technology required significantly fewer rehabilitation sessions to achieve those outcomes than the control group. A user-worn see-through display, utilizing a visual fixation target coupled with a stable artificial horizon and aligned with user movement, has demonstrated substantial benefit for individuals susceptible to motion intolerance and spatial disorientation and those undergoing vestibular rehabilitation. The technology developed has applications in any environment where motion sensitivity affects human performance.

  20. Emissions and Economics of Behind-the-Meter Electricity Storage.

    PubMed

    Fisher, Michael J; Apt, Jay

    2017-02-07

    Annual installations of behind-the-meter (BTM) electric storage capacity are forecast to eclipse grid-side electrochemical storage by the end of the decade. Here, we characterize the economic payoff and regional emission consequences of BTM storage without colocated generation under different tariff conditions, battery characteristics, and ownership scenarios using metered loads for several hundred commercial and industrial customers. Net emissions are calculated as increased system emissions from charging minus avoided emissions from discharging. Net CO 2 emissions range from 75 to 270 kg/MWh of delivered energy depending on location and ownership perspective, though in New York, these emissions can be reduced with careful tariff design. Net NO x emissions range from -0.13 to 0.24 kg/MWh, and net SO 2 emissions range from -0.01 to 0.58 kg/MWh. Emission rates are driven primarily by energy losses, not by the difference between marginal emission rates during battery charging and discharging. Economics are favorable for many buildings in regions with high demand charges like California and New York, even without subsidies. Future penetration into regions with average charges like Pennsylvania will depend greatly on installation cost reductions and wholesale prices for ancillary services.

  1. Image dissector camera system study

    NASA Technical Reports Server (NTRS)

    Howell, L.

    1984-01-01

    Various aspects of a rendezvous and docking system using an image dissector detector as compared to a GaAs detector were discussed. Investigation into a gimbled scanning system is also covered and the measured video response curves from the image dissector camera are presented. Rendezvous will occur at ranges greater than 100 meters. The maximum range considered was 1000 meters. During docking, the range, range-rate, angle, and angle-rate to each reflector on the satellite must be measured. Docking range will be from 3 to 100 meters. The system consists of a CW laser diode transmitter and an image dissector receiver. The transmitter beam is amplitude modulated with three sine wave tones for ranging. The beam is coaxially combined with the receiver beam. Mechanical deflection of the transmitter beam, + or - 10 degrees in both X and Y, can be accomplished before or after it is combined with the receiver beam. The receiver will have a field-of-view (FOV) of 20 degrees and an instantaneous field-of-view (IFOV) of two milliradians (mrad) and will be electronically scanned in the image dissector. The increase in performance obtained from the GaAs photocathode is not needed to meet the present performance requirements.

  2. Modern Foraminifera from a depth transect offshore Brunei Darussalam: diversity, sedimentation rate and preservation pathways.

    NASA Astrophysics Data System (ADS)

    Briguglio, Antonino; Goeting, Sulia; Kusli, Rosnani; Roslim, Amajida; Polgar, Gianluca; Kocsis, Laszlo

    2016-04-01

    For this study, 11 samples have been collected by scuba diving from 5 to 35 meters water depth off shore Brunei Darussalam. The locations sampled are known as: Pelong Rock (5 samples, shallow reef with soft and stony corals and larger foraminifera, 5 to 8 meters water depth), Abana Rock (1 sample, shallow reef with mainly soft corals and larger foraminifera, 13 to 18 meters water depth), Oil Rig wreck (1 sample, very sandy bottom with larger foraminifera, 18 meters water depth), Dolphin wreck (1 sample, muddy sand with many small rotaliids, 24 meters water depth), US wreck, (1 sample, sand with small clay fraction, 28 meters water depth), Australian wreck (1 sample, mainly medium to coarse sand with larger foraminifera, 34 meters water depth) and Blue water wreck (1 sample, mainly coarse sand, coral rubble and larger foraminifera, 35 meters water depth). Those samples closer to the river inputs are normally richer in clay, while the most distant samples are purely sandy. Some additional samples have been collected next to reef environments which, even if very shallow, are mainly sandy with almost no clay fraction. The deepest sample, which is 30 km offshore, contains some planktonic foraminifera and is characterized by a large range of preservations concerning foraminifera, thus testifying the presence or relict sediments at the sea bottom. The presence of relict sediments was already pointed out by older oil-related field studies offshore Brunei Darussalam, and now it is possible to draw the depth limit of these deposits. The diversity of the benthic foraminiferal fauna is relatively high but not as higher as neighboring regions as some studies have highlighted. The species collected and identified are more than 50: in reef environment the most abundant are Calcarina defrancii, Neorotalia calcar and the amphisteginidae; deeper in the muddy sediments the most abundant is Pararotalia schroeteriana and in the deepest sandy sample the most abundant are Calcarina hispida, followed by Operculina ammonoides.

  3. An aerial radiological survey of the Browns Ferry Nuclear Power Station and surrounding area, Decatur, Alabama

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, H.A.

    1986-10-01

    An aerial radiological survey was conducted during the period 12 July to 17 July 1985 over a 97-square-kilometer (37-square-mile) area centered on the Browns Ferry Nuclear Power Station located near Decatur, Alabama. The survey was conducted at a nominal altitude of 46 meters (150 feet) with line spacings of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate plus the cosmic exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on an aerial photograph and a USGS topographic map of the area. The terrestrial exposure rates north and east of Wheeler Lakemore » ranged from approximately 11 to 18 microroentgens per hour (..mu..R/h), while the area south and west of the lake ranged from approximately 9 to 11 ..mu..R/h. Two areas of increased exposure rate were evident. One of these areas was associated with the main units of the reactor facility, while the other was associated with a temporary radiological waste holding area inside the plant's protected area. A machine-aided search of the data for man-made sources of radiation indicated the presence of a third area within the plant facility. This area is utilized as a temporary low-level radioactive waste storage site. All three areas indicated the presence of Co-60. Soil samples and ion chamber measurements were obtained at four locations to support the aerial data. In addition, soil samples were also taken at six locations along the shore of Wheeler Lake. 8 refs., 13 figs., 4 tabs.« less

  4. Advanced solar concentrator mass production, operation, and maintenance cost assessment

    NASA Technical Reports Server (NTRS)

    Niemeyer, W. A.; Bedard, R. J.; Bell, D. M.

    1981-01-01

    The object of this assessment was to estimate the costs of the preliminary design at: production rates of 100 to 1,000,000 concentrators per year; concentrators per aperture diameters of 5, 10, 11, and 15 meters; and various receiver/power conversion package weights. The design of the cellular glass substrate Advanced Solar Concentrator is presented. The concentrator is an 11 meter diameter, two axis tracking, parabolic dish solar concentrator. The reflective surface of this design consists of inner and outer groups of mirror glass/cellular glass gores.

  5. System and technology considerations for space-based air traffic surveillance

    NASA Technical Reports Server (NTRS)

    Vaisnys, A.

    1986-01-01

    This paper describes the system trade-offs examined in a recent study of space-based air traffic surveillance. Three system options, each satisfying a set of different constraints, were considered. The main difference in the technology needed to implement the three systems was determined to be the size of the spacecraft antenna aperture. It was found that essentially equivalent position location accuracy could be achieved with apertures from 50 meters down to less than a meter in diameter, depending on the choice of signal structure and on the desired user update rate.

  6. Degradation and Characterization of Antimisting Kerosene (AMK).

    DTIC Science & Technology

    1981-06-01

    the pass/fail criterion in the JPL test, which is taken as a flame length of I meter, appeared to be different from the critical velocity in the...SPILLAG;E TEST 9 passed at velocities up to 80 m/s, the flame length in all these cases appeared to be about 1/2 to 3/4 meter and did not increase...significantly with air velocity from 50-80 m/s. More importantly, the flame length for the sample without amine, which was rated as a fail at 50 m/s (i.e., had

  7. A Conceptual Design For A Spaceborne 3D Imaging Lidar

    NASA Technical Reports Server (NTRS)

    Degnan, John J.; Smith, David E. (Technical Monitor)

    2002-01-01

    First generation spaceborne altimetric approaches are not well-suited to generating the few meter level horizontal resolution and decimeter accuracy vertical (range) resolution on the global scale desired by many in the Earth and planetary science communities. The present paper discusses the major technological impediments to achieving few meter transverse resolutions globally using conventional approaches and offers a feasible conceptual design which utilizes modest power kHz rate lasers, array detectors, photon-counting multi-channel timing receivers, and dual wedge optical scanners with transmitter point-ahead correction.

  8. Single ball bearing lubricant and material evaluator

    NASA Technical Reports Server (NTRS)

    Hall, Philip B. (Inventor); Novak, Howard L. (Inventor)

    2005-01-01

    A test apparatus provides an applied load to a monoball through a trolley which moves along a loading axis. While applying the load to the monoball, the torque meter is in communication with the spherical monoball, and a load cell senses the application of applied force to the monoball. Meanwhile, a rotary actuary imports rotary oscillating motion to the monoball which is sensed by a position sensor and a torque meter. Accordingly, a processor can determine the coefficient of friction in substantially real time along with a cycles per second rate.

  9. Single Ball Bearing Lubricant and Material Evaluator

    NASA Technical Reports Server (NTRS)

    Hall, Philip B. (Inventor); Novak, Howard L. (Inventor)

    2005-01-01

    A test apparatus provides an applied load to a monoball through a trolley which moves along a loading axis. While applying the load to the monoball, the torque meter is in communication with the spherical monoball, and a load cell senses the application of applied force to the monoball. Meanwhile, a rotary actuary imports rotary oscillating motion to the monoball which is sensed by a position sensor and a torque meter. Accordingly, a processor can determine the coefficient of friction in substantially real time along with a cycles per second rate.

  10. Analysis of tests of subsurface injection, storage, and recovery of freshwater in the lower Floridan aquifer, Okeechobee County, Florida

    USGS Publications Warehouse

    Quinones-Aponte, Vicente; Kotun, Kevin; Whitley, J.F.

    1996-01-01

    A series of freshwater subsurface injection, storage, and recovery tests were conducted at an injection-well site near Lake Okeechobee in Okeechobee County, Florida, to assess the recoverability of injected canal water from the Lower Floridan aquifer. At the study site, the Lower Floridan aquifer is characterized as having four local, relatively independent, high-permeability flow zones (389 to 398 meters, 419 to 424 meters, 456 to 462 meters, and 472 to 476 meters below sea level). Four subsurface injection, storage, and recovery cycles were performed at the Lake Okeechobee injection-well site in which volumes of water injected ranged from about 387,275 to 1,343,675 cubic meters for all the cycles, and volumes of water recovered ranged from about 106,200 to 484,400 cubic meters for cycles 1, 2, and 3. The recovery efficiency for successive cycles 2 and 3 increased from 22 to 36 percent and is expected to continue increasing with additional cycles. A comparison of chloride concentration breakthrough curves at the deep monitor well (located about 171 meters from the injection well) for cycles 1, 4, and test no. 4 (from a previous study) revealed unexpected finings. One significant result was that the concentration asymptote, expected to be reached at concentration levels equivalent or close to the injected water concentration, was instead reached at higher concentration levels. The injection to recovery rate ratio might affect the chloride concentration breakthrough curve at the deep monitor well, which could explain this unexpected behavior. Because there are four high-permeability zones, if the rate of injection is smaller than the rate of recovery (natural artesian flow), the head differential might not be transmitted through the entire open wellbore, and injected water would probably flow only through the upper high- permeability zones. Therefore, observed chloride concentration values at the deep monitor well would be higher than the concentration of the injected water and would represent a mix of water from the different high-permeability zones. A generalized digital model was constructed to simulate the subsurface injection, storage, and recovery of freshwater in the Lower Floridan aquifer at the Lake Okeechobee injection-well site. The model was constructed using a modified version of the Saturated-Unsaturated TRAnsport code (SUTRA), which simulates variable-density advective-dispersive solute transport and variable-density ground-water flow. Satisfactory comparisons of simulated to observed dimensionless chloride concentrations for the deep monitor well were obtained when using the model during the injection and recovery phases of cycle 1, but not for the injection well during the recovery phase of cycle 1 even after several attempts. This precluded the determination of the recovery efficiency values by using the model. The unsatisfactory comparisons of simulated to observed dimensionless chloride concentrations for the injection well and failure of the model to represent the field data at this well could be due to the characteristics of the Lower Floridan aquifer (at the local scale), which is cavernous or conduit in nature. To test this possibility, Reynolds numbers were estimated at varying distances from the injection well, taking into consideration two aquifer types or conceptual systems, porous media and cavernous. For the porous media conceptual system, the Reynolds numbers were greater than 10 at distances less than 1.42 meters from the injection well. Thus, application of Darcy's law to ground-water flow might not be valid at this distance. However, at the deep monitor well (171 meters from the injection well), the Reynolds number was 0.08 which is indicative of laminar porous media flow. For the cavernous conceptual system, the Reynolds numbers were greater than 2,000 at distances less than 1,000 meters from the well. This number represents the upper limit of laminar flow, which is the fundamental assumption

  11. Velocity profile survey in a 16-in. custody-transfer orifice meter for natural gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, J.J.S.

    1991-02-01

    This paper describes a research project conducted at Chevron U.S.A. Inc.'s Venice, LA, facility to ascertain that the flow condition inside a nominal 16-in. (406-mm) custody-transfer orifice meter was in compliance with American Gas Assn. (AGA) requirements. The survey was conducted at four flow rates ranging from 160 to 200 MMscf/D (4.53 {times} 10{sup 6} to 5.66 {times} 10{sup 6} std m{sup 3}/d) of processed natural gas at 880 psia (6.1 MPa). Experimental data were collected by a portable data-acquisition system driven by a lap-top microcomputer. The measured profiles indicated that the flow was nearly fully developed at the orificemore » plate location, and no significant swirling motion was detected. This test successfully demonstrated the techniques and equipment developed for determining actual flow distributions inside orifice meters in the field under normal operating conditions. This technology can be used to detect detrimental flow profiles and to verify compliance with AGA requirements on flow conditions in custody-transfer orifice meters.« less

  12. Compensation for Distributed Solar. A Survey of Options to Preserve Stakeholder Value

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flores-Espino, Francisco

    2015-09-01

    Compensation mechanisms for electricity generation systems installed behind the meter are under scrutiny in several jurisdictions in the United States. Legislators in 29 states introduced bills to amend net metering provisions in 2014, and in 33 states in the 2015 legislative session as of August 20, 2015. Some utilities have also sought to increase the revenue they receive from net-metered customers through rate redesign. The circumstances that have triggered the recent push for change include a growing percentage of net-metered customers, potential effects of distributed generation on cost allocation, decreasing photovoltaic (PV) system costs, the challenges of integrating high levelsmore » of solar generation in the distribution network, and increasing pressure on utility business models. This report presents a survey of options to charge and compensate PV customers, as well as options that may preserve utility revenues in scenarios with increased DG. These options could be used as building blocks to create a distributed generation (DG) compensation policy that may preserve the value of the different stakeholders and balance their interests.« less

  13. Air Compressibility Effect on Bouwer and Rice Seepage Meter.

    PubMed

    Peng, Xin; Zhan, Hongbin

    2017-11-01

    Measuring a disconnected streambed seepage flux using a seepage meter can give important streambed information and help understanding groundwater-surface water interaction. In this study, we provide a correction for calculating the seepage flux rate with the consideration of air compressibility inside the manometer of the Bouwer and Rice seepage meter. We notice that the effect of air compressibility in the manometer is considerably larger when more air is included in the manometer. We find that the relative error from neglecting air compressibility can be constrained within 5% if the manometer of the Bouwer and Rice seepage meter is shorter than 0.8 m and the experiment is done in a suction mode in which air is pumped out from the manometer before the start of measurement. For manometers longer than 0.8 m, the relative error will be larger than 5%. It may be over 10% if the manometer height is longer than 1.5 m and the experiment is done in a no-suction mode, in which air is not pumped out from the manometer before the start of measurement. © 2017, National Ground Water Association.

  14. The Role of Linear Acceleration in Visual-Vestibular Interactions and Implications in Aircraft Operations

    NASA Technical Reports Server (NTRS)

    Correia, Manning J.; Luke, Brian L.; McGrath, Braden J.; Clark, John B.; Rupert, Angus H.

    1996-01-01

    While considerable attention has been given to visual-vestibular interaction (VVI) during angular motion of the head as might occur during an aircraft spin, much less attention has been given to VVI during linear motion of the head. Such interaction might occur, for example, while viewing a stationary or moving display during vertical take-off and landing operations Research into linear VVI, particularly during prolonged periods of linear acceleration, has been hampered by the unavailability of a programmable translator capable of large excursions We collaborated with Otis Elevator Co. and used their research tower and elevator, whose motion could be digitally programmed, to vertically translate human subjects over a distance of 92.3 meters with a peak linear acceleration of 2 meters/sec(exp 2) During pulsatile or sinusoidal translation, the subjects viewed moving stripes (optokinetic stimulus) or a fixed point source (light emitting diode, led, display), respectively and it was generally found that. The direction of linear acceleration relative to the cardinal head axes and the direction of the slow component of optokinetic nystagmus (OKN) determined the extent of VVI during concomitant stripe motion and linear acceleration. Acceleration along the z head axis (A(sub z)) produced the largest VVI, particularly when the slow component of OKN was in the same direction as eye movements produced by the linear acceleration and Eye movements produced by linear acceleration are suppressed by viewing a fixed target at frequencies below 10 Hz But, above this frequency the suppression produced by VVI is removed. Finally, as demonstrated in non-human primates, vergence of the eyes appears to modulate the vertical eye movement response to linear acceleration in humans.

  15. Robots with Display Screens: A Robot with a More Humanlike Face Display Is Perceived To Have More Mind and a Better Personality

    PubMed Central

    Broadbent, Elizabeth; Kumar, Vinayak; Li, Xingyan; Sollers, John; Stafford, Rebecca Q.; MacDonald, Bruce A.; Wegner, Daniel M.

    2013-01-01

    It is important for robot designers to know how to make robots that interact effectively with humans. One key dimension is robot appearance and in particular how humanlike the robot should be. Uncanny Valley theory suggests that robots look uncanny when their appearance approaches, but is not absolutely, human. An underlying mechanism may be that appearance affects users’ perceptions of the robot’s personality and mind. This study aimed to investigate how robot facial appearance affected perceptions of the robot’s mind, personality and eeriness. A repeated measures experiment was conducted. 30 participants (14 females and 16 males, mean age 22.5 years) interacted with a Peoplebot healthcare robot under three conditions in a randomized order: the robot had either a humanlike face, silver face, or no-face on its display screen. Each time, the robot assisted the participant to take his/her blood pressure. Participants rated the robot’s mind, personality, and eeriness in each condition. The robot with the humanlike face display was most preferred, rated as having most mind, being most humanlike, alive, sociable and amiable. The robot with the silver face display was least preferred, rated most eerie, moderate in mind, humanlikeness and amiability. The robot with the no-face display was rated least sociable and amiable. There was no difference in blood pressure readings between the robots with different face displays. Higher ratings of eeriness were related to impressions of the robot with the humanlike face display being less amiable, less sociable and less trustworthy. These results suggest that the more humanlike a healthcare robot’s face display is, the more people attribute mind and positive personality characteristics to it. Eeriness was related to negative impressions of the robot’s personality. Designers should be aware that the face on a robot’s display screen can affect both the perceived mind and personality of the robot. PMID:24015263

  16. Robots with display screens: a robot with a more humanlike face display is perceived to have more mind and a better personality.

    PubMed

    Broadbent, Elizabeth; Kumar, Vinayak; Li, Xingyan; Sollers, John; Stafford, Rebecca Q; MacDonald, Bruce A; Wegner, Daniel M

    2013-01-01

    It is important for robot designers to know how to make robots that interact effectively with humans. One key dimension is robot appearance and in particular how humanlike the robot should be. Uncanny Valley theory suggests that robots look uncanny when their appearance approaches, but is not absolutely, human. An underlying mechanism may be that appearance affects users' perceptions of the robot's personality and mind. This study aimed to investigate how robot facial appearance affected perceptions of the robot's mind, personality and eeriness. A repeated measures experiment was conducted. 30 participants (14 females and 16 males, mean age 22.5 years) interacted with a Peoplebot healthcare robot under three conditions in a randomized order: the robot had either a humanlike face, silver face, or no-face on its display screen. Each time, the robot assisted the participant to take his/her blood pressure. Participants rated the robot's mind, personality, and eeriness in each condition. The robot with the humanlike face display was most preferred, rated as having most mind, being most humanlike, alive, sociable and amiable. The robot with the silver face display was least preferred, rated most eerie, moderate in mind, humanlikeness and amiability. The robot with the no-face display was rated least sociable and amiable. There was no difference in blood pressure readings between the robots with different face displays. Higher ratings of eeriness were related to impressions of the robot with the humanlike face display being less amiable, less sociable and less trustworthy. These results suggest that the more humanlike a healthcare robot's face display is, the more people attribute mind and positive personality characteristics to it. Eeriness was related to negative impressions of the robot's personality. Designers should be aware that the face on a robot's display screen can affect both the perceived mind and personality of the robot.

  17. Can Thermal Bending Fracture Ice Shelves?

    NASA Astrophysics Data System (ADS)

    MacAyeal, D. R.; Sergienko, O. V.; Banwell, A. F.; Willis, I.; Macdonald, G. J.; Lin, J.

    2017-12-01

    Visco-elastic plates will bend if the temperature on one side is cooled. If the plate is constrained to float, as for sea ice floes, this bending will lead to tensile stresses that can fracture the ice. The hydroacoustic regime below sea ice displays increased fracture-sourced noise when air temperatures above the ice cools with the diurnal cycle. The McMurdo Ice Shelf, Antarctica, also displays a massive increase in seismicity during the cooling phase of the diurnal cycle, and this motivates the question: Can surface cooling (or other forcing with thermal consequences) drive through-thickness fracture leading to iceberg calving? Past study of this question for sea ice gives an upper limit of ice-plate thickness (order meters) for which diurnal-scale thermal bending fracture can occur; but could cooling with longer time scales induce fracture of thicker ice plates? Given the seismic evidence of thermal bending fracture on the McMurdo Ice Shelf, the authors examine this question further.

  18. Fault gouge rheology under confined, high-velocity conditions

    NASA Astrophysics Data System (ADS)

    Reches, Z.; Madden, A. S.; Chen, X.

    2012-12-01

    We recently developed the experimental capability to investigate the shear properties of fine-grain gouge under confined conditions and high-velocity. The experimental system includes a rotary apparatus that can apply large displacements of tens of meters, slip velocity of 0.001- 2.0 m/s, and normal stress of 35 MPa (Reches and Lockner, 2010). The key new component is a Confined ROtary Cell (CROC) that can shear a gouge layer either dry or under pore-pressure. The pore pressure is controlled by two syringe pumps. CROC includes a ring-shape gouge chamber of 62.5 mm inner diameter, 81.25 mm outer diameter, and up to 3 mm thick gouge sample. The lower, rotating part of CROC contains the sample chamber, and the upper, stationary part includes the loading, hollow cylinder and setting for temperature, and dilation measurements, and pore-pressure control. Each side of the gouge chamber has two pairs of industrial, spring-energized, self-lubricating, teflon-graphite seals, built for particle media and can work at temperature up to 250 ded C. The space between each of the two sets of seals is pressurized by nitrogen. This design generates 'zero-differential pressure' on the inner seal (which is in contact with the gouge powder), and prevents gouge leaks. For the preliminary dry experiments, we used ~2.0 mm thick layers of room-dry kaolinite powder. Total displacements were on the order of meters and normal stress up to 4 MPa. The initial shear was accommodated by multiple internal slip surfaces within the kaolinite layer accommodated as oriented Riedel shear structures. Later, the shear was localized within a thin, plate-parallel Y-surface. The kaolinite layer was compacted at a quasi-asymptotic rate, and displayed a steady-state friction coefficient of ~ 0.5 with no clear dependence on slip velocity up to 0.15 m/s. Further experiments with loose quartz sand (grain size ~ 125 micron) included both dry runs and pore-pressure (distilled water) controlled runs. The sand was pressurized through a porous metal (Mott) plug. Comparison with effective stress calculations indicates the same friction coefficient of ~ 1.0 for the sand layer under dry and pressurized conditions. Both kaolinite and quartz sand experiments developed localized shear zones that were examined at the nano- and micro- scales with AFM, SEM and TEM. These zones displayed reduced grain sizes and cementation by local agglomeration. Kaolinite grains sheared in CROC experiment; scale bar = 1 micron.

  19. Increased aggressive and affiliative display behavior in intrauterine growth restricted (IUGR) baboons

    PubMed Central

    Huber, Hillary F; Ford, Susan M; Bartlett, Thad Q; Nathanielsz, Peter W

    2016-01-01

    Background We hypothesized intrauterine growth restricted offspring (IUGR) demonstrate higher rates of aggression and higher dominance ranks than control (CTR) offspring with normal weight at term; if aggressive behavior is advantageous during resource scarcity, developmental programming may lead to an association between aggression and IUGR. Methods We studied 22 group-housed baboons (ages 3-5 years). CTR (male n=8, female n=5) mothers ate ad libitum. IUGR (male n=4, female n=5) mothers were fed 70% feed eaten by CTR mothers during pregnancy and lactation. Results IUGR showed higher rates of aggressive displays (p<0.01) and friendly displays (p<0.02). Dominance ranks and physical aggression rates did not differ between groups. Conclusions High rates of IUGR aggressive display might reflect developmental programming of behavioral phenotypes enhancing fitness. Friendly displays may reflect reconciliation. Potential mechanisms include neurodevelopment and learning. Exploration of IUGR as a risk factor for behavioral patterns is important for developing diagnostic and therapeutic strategies. PMID:25891005

  20. Behaviour of one-step spray-coated carbon nanotube supercapacitor in ambient light harvester circuit with printed organic solar cell and electrochromic display

    PubMed Central

    Tuukkanen, Sampo; Välimäki, Marja; Lehtimäki, Suvi; Vuorinen, Tiina; Lupo, Donald

    2016-01-01

    A printed energy harvesting and storage circuit powered by ambient office lighting and its use to power a printed display is reported. The autonomous device is composed of three printed electronic components: an organic photovoltaic module, a carbon-nanotubes-only supercapacitor and an electrochromic display element. Components are fabricated from safe and environmentally friendly materials, and have been fabricated using solution processing methods, which translate into low-cost and high-throughput manufacturing. A supercapacitor made of spray-coated carbon nanotube based ink and aqueous NaCl electrolyte was charged using a printed organic photovoltaic module exposed to office lighting conditions. The supercapacitor charging rate, self-discharge rate and display operation were studied in detail. The supercapacitor self-discharge rate was found to depend on the charging rate. The fully charged supercapacitor was used as a power source to run the electrochromic display over 50 times. PMID:26957019

  1. Flight performance using a hyperstereo helmet-mounted display: post-flight debriefing questionnaire

    NASA Astrophysics Data System (ADS)

    Kalich, Melvyn E.; Rash, Clarence E.; Harding, Thomas H.; Jennings, Sion; Craig, Gregory; Stuart, Geoffrey W.

    2009-05-01

    Helmet-mounted display (HMD) designs have faced persistent head-supported mass and center of mass (CM) problems, especially HMD designs like night vision goggles (NVG) that utilize image intensification (I2) sensors mounted forward in front of the user's eyes. Relocating I2 sensors from the front to the sides of the helmet, at or below the transverse plane through the user's head CM, can resolve most of the CM problems. However, the resulting increase in the separation between the two I2 channels effectively increases the user's interpupillary distance (IPD). This HMD design is referred to as a hyperstero design and introduces the phenomenon of hyperstereopsis, a type of visual distortion where stereoscopic depth perception is exaggerated, particularly at distances under 200 feet (~60 meters). The presence of hyperstereopsis has been a concern regarding implementation of hyperstereo HMDs for rotary-wing aircraft. To address this concern, a flight study was conducted to assess the impact of hyperstereopsis on aircraft handling proficiency and pilot acceptance. Three rated aviators with differing levels of I2 and hyperstereo HMD experience conducted a series of flights that concentrated on low-level maneuvers over a two-week period. Initial and final flights were flown with a standard issue I2 device and a production hyperstereo design HMD. Interim flights were flown only with the hyperstereo HMD. Two aviators accumulated 8 hours of flight time with the hyperstereo HMD, while the third accumulated 6.9 hours. This paper presents data collected via written questionnaires completed by the aviators during the post-flight debriefings. These data are compared to questionnaire data from a previous flight investigation in which aviators in a copilot capacity, hands not on the flight controls, accumulated 8 flight hours of flight time using a hyperstereo HMD.

  2. Advantages to Geoscience and Disaster Response from QuakeSim Implementation of Interferometric Radar Maps in a GIS Database System

    NASA Astrophysics Data System (ADS)

    Parker, Jay; Donnellan, Andrea; Glasscoe, Margaret; Fox, Geoffrey; Wang, Jun; Pierce, Marlon; Ma, Yu

    2015-08-01

    High-resolution maps of earth surface deformation are available in public archives for scientific interpretation, but are primarily available as bulky downloads on the internet. The NASA uninhabited aerial vehicle synthetic aperture radar (UAVSAR) archive of airborne radar interferograms delivers very high resolution images (approximately seven meter pixels) making remote handling of the files that much more pressing. Data exploration requiring data selection and exploratory analysis has been tedious. QuakeSim has implemented an archive of UAVSAR data in a web service and browser system based on GeoServer (http://geoserver.org). This supports a variety of services that supply consistent maps, raster image data and geographic information systems (GIS) objects including standard earthquake faults. Browsing the database is supported by initially displaying GIS-referenced thumbnail images of the radar displacement maps. Access is also provided to image metadata and links for full file downloads. One of the most widely used features is the QuakeSim line-of-sight profile tool, which calculates the radar-observed displacement (from an unwrapped interferogram product) along a line specified through a web browser. Displacement values along a profile are updated to a plot on the screen as the user interactively redefines the endpoints of the line and the sampling density. The profile and also a plot of the ground height are available as CSV (text) files for further examination, without any need to download the full radar file. Additional tools allow the user to select a polygon overlapping the radar displacement image, specify a downsampling rate and extract a modest sized grid of observations for display or for inversion, for example, the QuakeSim simplex inversion tool which estimates a consistent fault geometry and slip model.

  3. Benthic reef primary production in response to large amplitude internal waves at the Similan Islands (Andaman Sea, Thailand).

    PubMed

    Jantzen, Carin; Schmidt, Gertraud M; Wild, Christian; Roder, Cornelia; Khokiattiwong, Somkiat; Richter, Claudio

    2013-01-01

    Coral reefs are facing rapidly changing environments, but implications for reef ecosystem functioning and important services, such as productivity, are difficult to predict. Comparative investigations on coral reefs that are naturally exposed to differing environmental settings can provide essential information in this context. One prevalent phenomenon regularly introducing alterations in water chemistry into coral reefs are internal waves. This study therefore investigates the effect of large amplitude internal waves (LAIW) on primary productivity in coral reefs at the Similan Islands (Andaman Sea, Thailand). The LAIW-exposed west sides of the islands are subjected to sudden drops in water temperature accompanied by enhanced inorganic nutrient concentrations compared to the sheltered east. At the central island, Ko Miang, east and west reefs are only few hundred meters apart, but feature pronounced differences. On the west lower live coral cover (-38 %) coincides with higher turf algae cover (+64 %) and growth (+54 %) compared to the east side. Turf algae and the reef sand-associated microphytobenthos displayed similar chlorophyll a contents on both island sides, but under LAIW exposure, turf algae exhibited higher net photosynthesis (+23 %), whereas the microphytobenthos displayed reduced net and gross photosynthesis (-19 % and -26 %, respectively) accompanied by lower respiration (-42 %). In contrast, the predominant coral Porites lutea showed higher chlorophyll a tissues contents (+42 %) on the LAIW-exposed west in response to lower light availability and higher inorganic nutrient concentrations, but net photosynthesis was comparable for both sides. Turf algae were the major primary producers on the west side, whereas microphytobenthos dominated on the east. The overall primary production rate (comprising all main benthic primary producers) was similar on both island sides, which indicates high primary production variability under different environmental conditions.

  4. Benthic Reef Primary Production in Response to Large Amplitude Internal Waves at the Similan Islands (Andaman Sea, Thailand)

    PubMed Central

    Jantzen, Carin; Schmidt, Gertraud M.; Wild, Christian; Roder, Cornelia; Khokiattiwong, Somkiat; Richter, Claudio

    2013-01-01

    Coral reefs are facing rapidly changing environments, but implications for reef ecosystem functioning and important services, such as productivity, are difficult to predict. Comparative investigations on coral reefs that are naturally exposed to differing environmental settings can provide essential information in this context. One prevalent phenomenon regularly introducing alterations in water chemistry into coral reefs are internal waves. This study therefore investigates the effect of large amplitude internal waves (LAIW) on primary productivity in coral reefs at the Similan Islands (Andaman Sea, Thailand). The LAIW-exposed west sides of the islands are subjected to sudden drops in water temperature accompanied by enhanced inorganic nutrient concentrations compared to the sheltered east. At the central island, Ko Miang, east and west reefs are only few hundred meters apart, but feature pronounced differences. On the west lower live coral cover (-38 %) coincides with higher turf algae cover (+64 %) and growth (+54 %) compared to the east side. Turf algae and the reef sand-associated microphytobenthos displayed similar chlorophyll a contents on both island sides, but under LAIW exposure, turf algae exhibited higher net photosynthesis (+23 %), whereas the microphytobenthos displayed reduced net and gross photosynthesis (-19 % and -26 %, respectively) accompanied by lower respiration (-42 %). In contrast, the predominant coral Porites lutea showed higher chlorophyll a tissues contents (+42 %) on the LAIW-exposed west in response to lower light availability and higher inorganic nutrient concentrations, but net photosynthesis was comparable for both sides. Turf algae were the major primary producers on the west side, whereas microphytobenthos dominated on the east. The overall primary production rate (comprising all main benthic primary producers) was similar on both island sides, which indicates high primary production variability under different environmental conditions. PMID:24312365

  5. Tropical Cyclone Lightning Distribution and Its Relationship to Convection and Intensity Change

    NASA Technical Reports Server (NTRS)

    Rodgers, Edward; Wienman, James; Pierce, Harold; Olson, William

    2000-01-01

    The long distance National Lightning Detection Network (NLDN) was used to monitor the distribution of lightning strokes in various 1998 and 1999 western North Atlantic tropical cyclones. These ground-based lightning observations together with the Defense Meteorological Satellite Program (DMSP) Special Sensor Microwave/Imager (SSM/I) and the Tropical Rain Mapping Mission (TRMM) Microwave Instrument (TMI) derived convective rain rates were used to monitor the propagation of electrically charged convective rain bands aid to qualitatively estimate intensification. An example of the lightning analyses was performed on hurricane George between 25-28 September, 1998 when the system left Key West and moved towards the Louisiana coast. During this period of time, George's maximum winds increased from 38 to 45 meters per second on 25 September and then remained steady state until it made landfall. Time-radius displays of the lightning strokes indicated that the greatest number of lightning strokes occurred within the outer core region (greater than 165 km) with little or no lightning strokes at radii less than 165 km. The trend in these lightning strokes decreased as George move into the Gulf of Mexico and showed no inward propagation. The lack inward propagating lightning strokes with time indicated that there was no evidence that an eye wall replacement was occurring that could alter George's intensity. Since George was steady state at this time, this result is not surprising. Time-azimuth displays of lightning strokes in an annulus whose outer and inner radii were respectively, 222 and 333 km from George's center were also constructed. A result from this analysis indicated that the maximum number of strokes occurred in the forward and rear right quadrant when George was over the Gulf of Mexico. This result is, consistent with the aircraft and satellite observations of maximum rainfall.

  6. Closed-Loop Control of Chemical Injection Rate for a Direct Nozzle Injection System

    PubMed Central

    Cai, Xiang; Walgenbach, Martin; Doerpmond, Malte; Schulze Lammers, Peter; Sun, Yurui

    2016-01-01

    To realize site-specific and variable-rate application of agricultural pesticides, accurately metering and controlling the chemical injection rate is necessary. This study presents a prototype of a direct nozzle injection system (DNIS) by which chemical concentration transport lag was greatly reduced. In this system, a rapid-reacting solenoid valve (RRV) was utilized for injecting chemicals, driven by a pulse-width modulation (PWM) signal at 100 Hz, so with varying pulse width the chemical injection rate could be adjusted. Meanwhile, a closed-loop control strategy, proportional-integral-derivative (PID) method, was applied for metering and stabilizing the chemical injection rate. In order to measure chemical flow rates and input them into the controller as a feedback in real-time, a thermodynamic flowmeter that was independent of chemical viscosity was used. Laboratory tests were conducted to assess the performance of DNIS and PID control strategy. Due to the nonlinear input–output characteristics of the RRV, a two-phase PID control process obtained better effects as compared with single PID control strategy. Test results also indicated that the set-point chemical flow rate could be achieved within less than 4 s, and the output stability was improved compared to the case without control strategy. PMID:26805833

  7. Pneumatic shutoff and time-delay valve operates at controlled rate

    NASA Technical Reports Server (NTRS)

    Horning, J. L.; Tomlinson, L. E.

    1966-01-01

    Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

  8. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... rates or total flow sampled into a batch sampling system over a test interval. You may use the... rates or total raw exhaust flow over a test interval. (b) Component requirements. We recommend that you... averaging Pitot tube, or a hot-wire anemometer. Note that your overall system for measuring sample flow must...

  9. Methods for accurate estimation of net discharge in a tidal channel

    USGS Publications Warehouse

    Simpson, M.R.; Bland, R.

    2000-01-01

    Accurate estimates of net residual discharge in tidally affected rivers and estuaries are possible because of recently developed ultrasonic discharge measurement techniques. Previous discharge estimates using conventional mechanical current meters and methods based on stage/discharge relations or water slope measurements often yielded errors that were as great as or greater than the computed residual discharge. Ultrasonic measurement methods consist of: 1) the use of ultrasonic instruments for the measurement of a representative 'index' velocity used for in situ estimation of mean water velocity and 2) the use of the acoustic Doppler current discharge measurement system to calibrate the index velocity measurement data. Methods used to calibrate (rate) the index velocity to the channel velocity measured using the Acoustic Doppler Current Profiler are the most critical factors affecting the accuracy of net discharge estimation. The index velocity first must be related to mean channel velocity and then used to calculate instantaneous channel discharge. Finally, discharge is low-pass filtered to remove the effects of the tides. An ultrasonic velocity meter discharge-measurement site in a tidally affected region of the Sacramento-San Joaquin Rivers was used to study the accuracy of the index velocity calibration procedure. Calibration data consisting of ultrasonic velocity meter index velocity and concurrent acoustic Doppler discharge measurement data were collected during three time periods. Two sets of data were collected during a spring tide (monthly maximum tidal current) and one of data collected during a neap tide (monthly minimum tidal current). The relative magnitude of instrumental errors, acoustic Doppler discharge measurement errors, and calibration errors were evaluated. Calibration error was found to be the most significant source of error in estimating net discharge. Using a comprehensive calibration method, net discharge estimates developed from the three sets of calibration data differed by less than an average of 4 cubic meters per second, or less than 0.5% of a typical peak tidal discharge rate of 750 cubic meters per second.

  10. Monitoring Coastal Change after the Tsunami in Thailand

    NASA Astrophysics Data System (ADS)

    Pantanahiran, W.

    2014-03-01

    The tsunami on December 26, 2004 caused widespread devastation along the coast of Thailand, especially in Ban Nam Khem, Phang Nga province. This disaster claimed more than 941 lives, with 502 other people missing when the storm surge caught the residents of this area. The coastal geomorphology was impacted by this disaster. The objectives of the research were to study the effect of the tsunami on coastal change and the recovery of coastal areas. Six time-series datasets of aerial photographs and satellite images from 2002, 2004, 2005, 2006, 2009, and 2010 were compared using the Geographic Information System (GIS). The results showed the effect of the tsunami on the buildings in the area. Fifty-eight point sixty-three percent of the buildings in the urban area were destroyed by the tsunami and constructions was raised to 103.60% and 197.12% between 2004 and 2010, thus indicating the recovery of the local community. Geomorphological change in Ko Kho Khao (the island) was found after the tsunami disaster, including coastal erosion and coastal deposition. The balance of nature played a major role in controlling the erosion and deposition. The coastal deposits were the highest in 2005; however, deposition was not found in 2004. The erosion rate from 2002-2003 was the highest (48.10 meter per year) and higher than 2003-2004 (39.03 meters per year), 2004-2009 (15.64 meters per year) and 2009-2010 (29.49 meters per year). The coastal area was more severe eroded than the estuary area, and severe coastal erosion caused the loss of coastal area, approximately 0.28 ha. Severe coastal erosion has been repeatedly found since 2005 in the lower part of the area, and hard structures such as concrete seawalls might have been affected by coastal erosion. In addition, extrapolation of coastal erosion at the rate of 30 meters per year showed that the lower part of Ko Kho Khao should disappear in 2015.

  11. Uranium bioreduction rates across scales: biogeochemical hot moments and hot spots during a biostimulation experiment at Rifle, Colorado.

    PubMed

    Bao, Chen; Wu, Hongfei; Li, Li; Newcomer, Darrell; Long, Philip E; Williams, Kenneth H

    2014-09-02

    We aim to understand the scale-dependent evolution of uranium bioreduction during a field experiment at a former uranium mill site near Rifle, Colorado. Acetate was injected to stimulate Fe-reducing bacteria (FeRB) and to immobilize aqueous U(VI) to insoluble U(IV). Bicarbonate was coinjected in half of the domain to mobilize sorbed U(VI). We used reactive transport modeling to integrate hydraulic and geochemical data and to quantify rates at the grid block (0.25 m) and experimental field scale (tens of meters). Although local rates varied by orders of magnitude in conjunction with biostimulation fronts propagating downstream, field-scale rates were dominated by those orders of magnitude higher rates at a few selected hot spots where Fe(III), U(VI), and FeRB were at their maxima in the vicinity of the injection wells. At particular locations, the hot moments with maximum rates negatively corresponded to their distance from the injection wells. Although bicarbonate injection enhanced local rates near the injection wells by a maximum of 39.4%, its effect at the field scale was limited to a maximum of 10.0%. We propose a rate-versus-measurement-length relationship (log R' = -0.63 log L - 2.20, with R' in μmol/mg cell protein/day and L in meters) for orders-of-magnitude estimation of uranium bioreduction rates across scales.

  12. Carbohydrate Partitioning and the Capacity of Apparent Nitrogen Fixation of Soybean Plants Grown Outdoors

    PubMed Central

    Millhollon, Eddie P.; Williams, Larry E.

    1986-01-01

    Patterns of leaf carbohydrate partitioning and nodule activity in soybean plants grown under natural conditions and the irradiance level required to produce sufficient carbohydrate to obtain maximum rates of apparent N2-fixation (acetylene reduction) were measured. Soybean plants, grown outdoors, maintained constant levels of leaf soluble sugars while leaf starch pools varied diurnally. When root temperature was kept at 25°C and shoot temperature was allowed to vary with ambient temperature, the plants maintained constant rates of apparent N2-fixation and root+nodule respiration. Results from a second experiment, in which the entire plant was kept at 25°C, were similar to those of the first experiment. Shoot carbon exchange rate of plants from the second experiment was light saturated at photosynthetic photon flux densities between 400 and 600 micromoles per square meter per second. When plants were subjected to an extended 40-hour dark period to deplete carbohydrate reserves, apparent N2-fixation was unaffected during the first 10 hours of darkness, decreased rapidly between 10 and 16 hours, and plateaued at one-third the initial level thereafter. After the extended dark period, plants were exposed to photosynthetic photon flux density from 200 to 1000 micromoles per square meter per second for 10 hours. Photosynthetic photon flux densities of 200 micromoles per square meter per second and greater resulted in maximum leaf soluble sugar content and nodule activity. Leaf starch content increased with irradiance levels up to 600 micromoles per square meter per second with no further increase at higher irradiance levels. Results presented here indicate that maximum nodule activity occurs at irradiance levels that do not saturate the plant's photosynthetic apparatus. This response would allow for maximum N2-fixation to occur in a nodulated legume during periods of inclement weather. PMID:16664789

  13. Contributions of pitch contour, tonality, rhythm, and meter to melodic similarity.

    PubMed

    Prince, Jon B

    2014-12-01

    The identity of a melody resides in its sequence of pitches and durations, both of which exhibit surface details as well as structural properties. In this study, pitch contour (pattern of ups and downs) served as pitch surface information, and tonality (musical key) as pitch structure; in the temporal dimension, surface information was the ordinal duration ratios of adjacent notes (rhythm), and meter (beat, or pulse) comprised the structure. Factorially manipulating the preservation or alteration of all of these forms of information in 17 novel melodies (typifying Western music) enabled measuring their effect on perceived melodic similarity. In Experiment 1, 34 participants (varied musical training) rated the perceived similarity of melody pairs transposed to new starting pitches. Rhythm was the largest contributor to perceived similarity, then contour, meter, and tonality. Experiment 2 used the same melodies but varied the tempo within a pair, and added a prefix of 3 chords, which oriented the listener to the starting pitch and tempo before the melody began. Now contour was the strongest influence on similarity ratings, followed by tonality, and then rhythm; meter was not significant. Overall, surface features influenced perceived similarity more than structural, but both had observable effects. The primary theoretical advances in melodic similarity research are that (a) the relative emphasis on pitch and temporal factors is flexible; (b) pitch and time functioned independently when factorially manipulated, regardless of which dimension is more influential; and (c) interactions between surface and structural information were unreliable and never occurred between dimensions. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  14. 1-mm catheterscope

    NASA Astrophysics Data System (ADS)

    Seibel, Eric J.

    2008-02-01

    Flexible endoscopes use one sensor element per display pixel. When diameter is reduced to the size of a catheter, there is a significant reduction in the number of pixels within the image. By placing a sub-millimeter microscanner at the tip of a catheter, image quality can be significantly improved. The microscanner consists of a 0.4 mm diameter piezoelectric tube with quadrant electrodes, surrounding a cantilevered singlemode optical fiber. At the distal end, the fiber microscanner is sealed with a 0.9 mm diameter lens assembly, creating a rigid length less than 10 mm at the tip of a highly flexible shaft. The cantilevered fiber is vibrated at the first mode of resonance for bending to generate a circular scan pattern. A spiral scan pattern is generated that constitutes an image frame by modulating the piezoelectric drive signals. By using a custom optical fiber at 80 microns cladding diameter, >10 KHz resonant scanning is achieved, resulting in a 30 Hz frame rate. Red (635 nm), green (532 nm), and blue (442 nm) laser light is scanned by coupling to the fiber scanner. The scanned illumination is detected in a non-confocal arrangement by having one or more optical fibers collecting the backscattered light at MHz pixel rates. Current 1-mm diameter catheterscopes generate 500-line images at maximum fields of view of 100 degrees and spatial resolutions of <20 microns with image zooming. Shaft length of four meters have been fabricated with flexibility of <10 mm bending radius to image previously inaccessible regions of the body.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlapati, Shravan K; Kuruganti, Phani Teja; Buehrer, Richard M

    The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion.more » Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.« less

  16. A Remote Monitoring System for Voltage, Current, Power and Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Barakat, E.; Sinno, N.; Keyrouz, C.

    This paper presents a study and design of a monitoring system for the continuous measurement of electrical energy parameters such as voltage, current, power and temperature. This system is designed to monitor the data remotely over internet. The electronic power meter is based on a microcontroller from Microchip Technology Inc. PIC family. The design takes into consideration the correct operation in the event of an outage or brown out by recording the electrical values and the temperatures in EEPROM internally available in the microcontroller. Also a digital display is used to show the acquired measurements. A computer will remotely monitor the data over internet.

  17. A 1-2 GHz pulsed and continuous wave electron paramagnetic resonance spectrometer

    NASA Astrophysics Data System (ADS)

    Quine, Richard W.; Rinard, George A.; Ghim, Barnard T.; Eaton, Sandra S.; Eaton, Gareth R.

    1996-07-01

    A microwave bridge has been constructed that performs three types of electron paramagnetic resonance experiments: continuous wave, pulsed saturation recovery, and pulsed electron spin echo. Switching between experiment types can be accomplished via front-panel switches without moving the sample. Design features and performance of the bridge and of a resonator used in testing the bridge are described. The bridge is constructed of coaxial components connected with semirigid cable. Particular attention has been paid to low-noise design of the preamplifier and stability of automatic frequency control circuits. The bridge incorporates a Smith chart display and phase adjustment meter for ease of tuning.

  18. Geodetic positioning of the Aerospace Electronics Research Lab (ERL) Osborne Time Transfer Receiver (TTR) using the GPS NAVSTAR Block I satellites

    NASA Technical Reports Server (NTRS)

    Liu, Anthony S.

    1990-01-01

    Aerospace has routinely processed the Osborne Time Transfer Receiver (TTR) data for the purpose of monitoring the performance of ground and GPS atomic clocks in near real-time with on-line residual displays and characterizing clock stability with Allan Variance calculations. Recently, Aerospace added the ability to estimate the TTR's location by differentially correcting the TTR's location in the WGS84 reference system. This new feature is exercised on a set of TTR clock phase data and Sub-meter accurate station location estimates of the TTR at the Aerospace Electronic Research Lab (ERL) are obtained.

  19. A method for the measurement of extremely feeble torques on massive bodies.

    NASA Technical Reports Server (NTRS)

    Boyle, J. C.; Greyerbiehl, J. M.

    1966-01-01

    Single-axis meter design and development for measuring feeble torques on massive bodies, discussing calibration, testing results, evaluation of static dipole moments and spacecraft spin-rate control moments

  20. Useful method to monitor the physiological effects of alcohol ingestion by combination of micro-integrated laser Doppler blood flow meter and arm-raising test.

    PubMed

    Iwasaki, Wataru; Nogami, Hirofumi; Ito, Hiroki; Gotanda, Takeshi; Peng, Yao; Takeuchi, Satoshi; Furue, Masutaka; Higurashi, Eiji; Sawada, Renshi

    2012-10-01

    Alcohol has a variety of effects on the human body, affecting both the sympathetic and parasympathetic nervous system. We examined the peripheral blood flow of alcohol drinkers using a micro-integrated laser Doppler blood flow meter (micro-electromechanical system blood flow sensor). An increased heart rate and blood flow was recorded at the earlobe after alcohol ingestion, and we observed strong correlation between blood flow, heart rate, and breath alcohol content in light drinkers; but not heavy drinkers. We also found that the amplitude of pulse waves measured at the fingertip during an arm-raising test significantly decreased on alcohol consumption, regardless of the individual's alcohol tolerance. Our micro-electromechanical system blood flow sensor successfully detected various physiological changes in peripheral blood circulation induced by alcohol consumption.

  1. Oxygen isotope ratios in trees reflect mean annual temperature and humidity.

    PubMed

    Burk, R L; Stuiver, M

    1981-03-27

    Values of the oxygen isotope ratios (delta(18)O) in tree-ring cellulose closely reflect the delta(18)O values in atmospheric precipitation and hence mean annual temperature. The change in delta(18)O in cellulose is 0.41 per mil per degree Celsius for selected near-coastal stations. The values of delta(18)O in precipitation and cellulose also change with altitude, as demonstrated for Mount Rainier, Washington. A temperature lapse rate of 5.2 degrees +/- 0.5 degrees C per 1000 meters calculated from cellulose delta(18)O values agrees with the accepted mean annual lapse rate of 5 degrees C per 1000 meters for this region. Cellulose delta(18)O values and delta(18)O values of carbon dioxide equilibrated with leaf water differ by a fixed 16 per mil.

  2. Stage-Discharge Relations for the Colorado River in Glen, Marble, and Grand Canyons, Arizona, 1990-2005

    USGS Publications Warehouse

    Hazel, Joseph E.; Kaplinski, Matt; Parnell, Rod; Kohl, Keith; Topping, David J.

    2007-01-01

    This report presents stage-discharge relations for 47 discrete locations along the Colorado River, downstream from Glen Canyon Dam. Predicting the river stage that results from changes in flow regime is important for many studies investigating the effects of dam operations on resources in and along the Colorado River. The empirically based stage-discharge relations were developed from water-surface elevation data surveyed at known discharges at all 47 locations. The rating curves accurately predict stage at each location for discharges between 141 cubic meters per second and 1,274 cubic meters per second. The coefficient of determination (R2) of the fit to the data ranged from 0.993 to 1.00. Given the various contributing errors to the method, a conservative error estimate of ?0.05 m was assigned to the rating curves.

  3. Open-channel integrating-type flow meter

    USGS Publications Warehouse

    Koopman, K.C.

    1971-01-01

    A relatively inexpensive meter for measuring cumulative flow in open channels with a rated control,. called a "totalizer", was developed. It translates the nonlinear function of gage height to flow by use of a cam and a float. A variable resistance element in an electronic circuit is controlled by the float so that the electron flow in the circuit corresponds to the flow of water. The flow of electricity causes electroplating of an electrode with silver. The amount of silver deposited is proportionate to the flow of water. The total flow of water is determined by removing the silver from the electrode at a fixed rate with ·an electronic device and recording the time for removal with a counter. The circuit is designed so that the ,resultant reading on the counter is in acre-feet of water.

  4. The relationship between ground reaction force in sit-to-stand movement and lower extremity function in community-dwelling Japanese older adults using long-term care insurance services

    PubMed Central

    Shen, Shaoshuai; Abe, Takumi; Tsuji, Taishi; Fujii, Keisuke; Ma, Jingyu; Okura, Tomohiro

    2017-01-01

    [Purpose] The purpose of this study was to investigate which of the four chair-rising methods has low-load and the highest success rate, and whether the GRF parameters in that method are useful for measuring lower extremity function among physically frail Japanese older adults. [Subjects and Methods] Fifty-two individuals participated in this study. The participants voluntarily attempted four types of Sit-to-stand test (one variation without and three variations with the use of their arms). The following parameters were measured: peak reaction force (F/w), two force development rate parameters (RFD1.25/w, RFD8.75/w) and two time-related parameters (T1, T2). Three additional commonly employed clinical tests (One-leg balance with eyes open, Timed up and go and 5-meter walk test) were also conducted. [Results] “Hands on a chair” chair-rising method produced the highest success rate among the four methods. All parameters were highly reliable between testing occasions. T2 showed strongly significant associations with Timed up and go and 5-meter walk test in males. RFD8.75/w showed significant associations with Timed up and go and 5-meter walk test in females. [Conclusion] Ground reaction force parameters in the Sit-to-stand test are a reliable and useful method for assessment of lower extremity function in physically frail Japanese older adults. PMID:28931988

  5. Development and evaluation of an ultrasonic ground water seepage meter.

    PubMed

    Paulsen, R J; Smith, C F; O'Rourke, D; Wong, T F

    2001-01-01

    Submarine ground water discharge can influence significantly the near-shore transport and flux of chemicals into the oceans. Quantification of the sources and rates of such discharge requires a ground water seepage meter that provides continuous measurements at high resolution over an extended period of time. An ultrasonic flowmeter has been adapted for such measurements in the submarine environment. Connected to a steel collection funnel, the meter houses two piezoelectric transducers mounted at opposite ends of a cylindrical flow tube. By monitoring the perturbations of fluid flow on the propagation of sound waves inside the flow tube, the ultrasonic meter can measure both forward and reverse fluid flows in real time. Laboratory and field calibrations show that the ultrasonic meter can resolve ground water discharges on the order of 0.1 microm/sec, and it is sufficiently robust for deployment in the field for several days. Data from West Neck Bay, Shelter Island, New York, elucidate the temporal and spatial heterogeneity of submarine ground water discharge and its interplay with tidal loading. A negative correlation between the discharge and tidal elevation was generally observed. A methodology was also developed whereby data for the sound velocity as a function of temperature can be used to infer the salinity and source of the submarine discharge. Independent measurements of electrical conductance were performed to validate this methodology.

  6. Guide to Flow Measurement for Electric Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Frieman, Jason D.; Walker, Mitchell L. R.; Snyder, Steve

    2013-01-01

    In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

  7. Flow metering valve

    DOEpatents

    Blaedel, K.L.

    1983-11-03

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  8. Flow metering valve

    DOEpatents

    Blaedel, Kenneth L.

    1985-01-01

    An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

  9. Gas exchange-wind speed relation measured with sulfur hexafluoride on a lake

    NASA Technical Reports Server (NTRS)

    Wanninkhof, R.; Broecker, W. S.; Ledwell, J. R.

    1985-01-01

    Gas-exchange processes control the uptake and release of various gases in natural systems such as oceans, rivers, and lakes. Not much is known about the effect of wind speed on gas exchange in such systems. In the experiment described here, sulfur hexafluoride was dissolved in lake water, and the rate of escape of the gas with wind speed (at wind speeds up to 6 meters per second) was determined over a 1-month period. A sharp change in the wind speed dependence of the gas-exchange coefficient was found at wind speeds of about 2.4 meters per second, in agreement with the results of wind-tunnel studies. However the gas-exchange coefficients at wind speeds above 3 meters per second were smaller than those observed in wind tunnels and are in agreement with earlier lake and ocean results.

  10. MINIMAL ENDOILLUMINATION LEVELS AND DISPLAY LUMINOUS EMITTANCE DURING THREE-DIMENSIONAL HEADS-UP VITREORETINAL SURGERY.

    PubMed

    Adam, Murtaza K; Thornton, Sarah; Regillo, Carl D; Park, Carl; Ho, Allen C; Hsu, Jason

    2017-09-01

    To determine minimal endoillumination levels required to perform 3-dimensional heads-up vitreoretinal surgery and to correlate endoillumination levels used for measurements of heads-up display (HUD) luminous emittance. Prospective, observational surgical case series of 10 patients undergoing vitreoretinal surgery. Endoillumination levels were set to 40% of maximum output and were decreased at set intervals until the illumination level was 0%. Corresponding luminous emittance (lux) of the HUD was measured 40 cm from the display using a luxmeter (Dr. Meter, Model #LX1010BS). In 9 of 10 cases, the surgeon felt that they could operate comfortably at an endoillumination level of 10% of maximum output with corresponding HUD emittance of 14.3 ± 9.5 lux. In the remaining case, the surgeon felt comfortable at a 3% endoillumination level with corresponding HUD emittance of 15 lux. Below this threshold, subjective image dimness and digital noise limited visibility. Endoillumination levels were correlated with luminous emittance from the 3-dimensional HUD (P < 0.01). The average coefficient of variation of HUD luminance was 0.546. There were no intraoperative complications. With real-time digital processing and automated brightness control, 3-dimensional HUD platforms may allow for reduced intraoperative endoillumination levels and a theoretically reduced risk of retinal phototoxicity during vitreoretinal surgery.

  11. An improved instantaneous frequency meter for use with a multi-trace CRO: re-examination of the principles involved.

    PubMed

    Obara, S; Nagai, T

    1983-01-01

    The instantaneous frequency display of single unit discharges provides a useful measure of neuronal activities. Such a device must produce voltage outputs proportional to the reciprocal of each inter-spike interval by on-line computation of the hyperbola of V = a/t. Segment approximation of the required hyperbola can be made by a series of exponential functions which increase in time constants by a factor of m. Numerical analysis of a normalized function indicates possible error maxima of 3.4, 2.4 and 1.1% for m of 2, 1.8 and 1.5, respectively. This prediction is fully confirmed by the actual performance where m of 1.5 is adopted. The test circuit combines only readily available ICs and other components, to give a linear F-V conversion over a dynamic range of 4-600 Hz with error maxima of approximately 1%. The outputs are square pulses of approximately 1.5 ms in duration through the use of a flexible sample-hold circuit. Compared with that of earlier models, this display mode gives better photographic records with the base-line in simultaneous multi-trace display. Simple and systematic methods are described for designing a circuit to one's own specifications, and also for compensating for component variations.

  12. Global Distribution of Net Electron Acceptance in Subseafloor Sediment

    NASA Astrophysics Data System (ADS)

    Fulfer, V. M.; Pockalny, R. A.; D'Hondt, S.

    2017-12-01

    We quantified the global distribution of net electron acceptance rates (e-/m2/year) in subseafloor sediment (>1.5 meters below seafloor [mbsf]) using (i) a modified version of the chemical-reaction-rate algorithm by Wang et al. (2008), (ii) physical properties and dissolved oxygen and sulfate data from interstitial waters of sediment cores collected by the Ocean Drilling Program, Integrated Ocean Drilling Program, International Ocean Discovery Program, and U.S. coring expeditions, and (iii) correlation of net electron acceptance rates to global oceanographic properties. Calculated net rates vary from 4.8 x 1019 e-/m2/year for slowly accumulating abyssal clay to 1.2 x 1023 e-/m2/year for regions of high sedimentation rate. Net electron acceptance rate correlates strongly with mean sedimentation rate. Where sedimentation rate is very low (e.g., 1 m/Myr), dissolved oxygen penetrates more than 70 mbsf and is the primary terminal electron acceptor. Where sedimentation rate is moderate (e.g., 3 to 60 m/Myr), dissolved sulfate penetrates as far as 700 mbsf and is the principal terminal electron acceptor. Where sedimentation rate is high (e.g., > 60 m/Myr), dissolved sulfate penetrates only meters, but is the principal terminal electron acceptor in subseafloor sediment to the depth of sulfate penetration. Because microbial metabolism continues at greater depths than the depth of sulfate penetration in fast-accumulating sediment, complete quantification of subseafloor metabolic rates will require consideration of other chemical species.

  13. An investigation of deformation and fluid flow at subduction zones using newly developed instrumentation and finite element modeling

    NASA Astrophysics Data System (ADS)

    Labonte, Alison Louise

    Detecting seafloor deformation events in the offshore convergent margin environment is of particular importance considering the significant seismic hazard at subduction zones. Efforts to gain insight into the earthquake cycle have been made at the Cascadia and Costa Rica subduction margins through recent expansions of onshore GPS and seismic networks. While these studies have given scientists the ability to quantify and locate slip events in the seismogenic zone, there is little technology available for adequately measuring offshore aseismic slip. This dissertation introduces an improved flow meter for detecting seismic and aseismic deformation in submarine environments. The value of such hydrologic measurements for quantifying the geodetics at offshore margins is verified through a finite element modeling (FEM) study in which the character of deformation in the shallow subduction zone is determined from previously recorded hydrologic events at the Costa Rica Pacific margin. Accurately sensing aseismic events is one key to determining the stress state in subduction zones as these slow-slip events act to load or unload the seismogenic zone during the interseismic period. One method for detecting seismic and aseismic strain events is to monitor the hydrogeologic response to strain events using fluid flow meters. Previous instrumentation, the Chemical Aqueous Transport (CAT) meter which measures flow rates through the sediment-water interface, can detect transient events at very low flowrates, down to 0.0001 m/yr. The CAT meter performs well in low flow rate environments and can capture gradual changes in flow rate, as might be expected during ultra slow slip events. However, it cannot accurately quantify high flow rates through fractures and conduits, nor does it have the temporal resolution and accuracy required for detecting transient flow events associated with rapid deformation. The Optical Tracer Injection System (OTIS) developed for this purpose is an electronic flow meter that can measure flow rates of 0.1 to >500 m/yr at a temporal resolution of 30 minutes to 0.5 minutes, respectively. Test deployments of the OTIS at cold seeps in the transpressional Monterey Bay demonstrated the OTIS functionality over this range of flow environments. Although no deformation events were detected during these test deployments, the OTIS's temporally accurate measurements at the vigorously flowing Monterey Bay cold seep rendered valuable insight into the plumbing of the seep system. In addition to the capability to detect transient flow events, a primary functional requirement of the OTIS was the ability to communicate and transfer data for long-term real-time monitoring deployments. Real-time data transfer from the OTIS to the desktop was successful during a test deployment of the Nootka Observatory, an acoustically-linked moored-buoy system. A small array of CAT meters was also deployed at the Nootka transform-Cascadia subduction zone triple junction. Four anomalous flow rate events were observed across all four meters during the yearlong deployment. Although the records have low temporal accuracy, a preliminary explanation for the regional changes in flow rate is made through comparison between flow rate records and seismic records. The flow events are thought to be a result of a tectonic deformation event, possibly with an aseismic component. Further constraints are not feasible given the unknown structure of faulting near the triple junction. In a final proof of concept study, I find that use these hydrologic instruments, which capture unique aseismic flow rate patterns, is a valuable method for extracting information about deformation events on the decollement in the offshore subduction zone margin. Transient flow events observed in the frontal prism during a 1999--2000 deployment of CAT meters on the Costa Rica Pacific margin suggest episodic slow-slip deformation events may be occurring in the shallow subduction zone. The FEM study to infer the character of the hypothetical deformation event driving flow transients verify that indeed, a shallow slow-slip event can reproduce the unique flow rate patterns observed. Along (trench) strike variability in the rupture initiation location, and bidirectional propagation, is one way to explain the opposite sign of flow rate transients observed at different along-strike distances. The larger question stimulated by this dissertation project, is: What are the controls on fault mechanics in offshore subduction zone environments? It appears the shallow subduction zone plate interface doesn't behave solely in response to frictional properties of the sediment lining the decollement. Shallow episodic slip at the Costa Rica Pacific margin and further north off Nicaragua, where a slow earthquake broke through the shallow 'stable-sliding' zone and resulted in a tsunami, are potentially conceived through the normally faulted incoming basement topography. Scientists should seek to map out the controls of faulting mechanics, whatever they may be, at all temporal and spatial scales in order to understand these dynamic subduction zone systems. The quest to understanding these controls, in part, requires the characterization of aseismic and seismic strain occurring over time and space. The techniques presented in this dissertation advance scientists' capability for quantifying such strains. With the new instrumentation presented here, long-term real-time observatory networks on the seafloor, and modeling for characterization of deformation events, the pieces of the subduction zone earthquake cycle puzzle may start to come together.

  14. A programmable display layer for virtual reality system architectures.

    PubMed

    Smit, Ferdi Alexander; van Liere, Robert; Froehlich, Bernd

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We describe an architecture that provides a programmable display layer (PDL) in order to generate updated display frames. This replaces the default display behavior of repeating application frames until an update is available. We will show three benefits of the architecture typical to VR. First, smooth motion is provided by generating intermediate display frames by per-pixel depth-image warping using 3D motion fields. Smooth motion eliminates various perceptual artifacts due to judder. Second, we implement fine-grained latency reduction at the display frame level using a synchronized prediction of simulation objects and the viewpoint. This improves the average quality and consistency of latency reduction. Third, a crosstalk reduction algorithm for consecutive display frames is implemented, which improves the quality of stereoscopic images. To evaluate the architecture, we compare image quality and latency to that of a classic level-of-detail approach.

  15. Human factors flight trial analysis for 3D SVS: part II

    NASA Astrophysics Data System (ADS)

    Schiefele, Jens; Howland, Duncan; Maris, John; Pschierer, Christian; Wipplinger, Patrick; Meuter, Michael

    2005-05-01

    This paper describes flight trials performed in Centennial, CO using a Piper Cheyenne owned and operated by Marinvent. The goal of the flight trial was to evaluate the objective performance of pilots using conventional paper charts or a 3D SVS display. Six pilots flew thirty-six approaches to the Colorado Springs airport to accomplish this goal. As dependent variables, positional accuracy and situational awareness probe (SAP) statistics were measured while analysis was conducted by an ANOVA test. In parallel, all pilots answered subjective Cooper-Harper, NASA TLX, situation awareness rating technique (SART), Display Readability Rating, Display Flyability Rating and debriefing questionnaires. Three different settings (paper chart, electronic navigation chart, 3D SVS display) were evaluated in a totally randomized manner. This paper describes the comparison between the conventional paper chart and the 3D SVS display. The 3D SVS primary flight display provides a depiction of primary flight data as well as a 3D depiction of airports, terrain and obstacles. In addition, a 3D dynamic channel visualizing the selected approach procedure can be displayed. The result shows that pilots flying the 3D SVS display perform no worse than pilots with the conventional paper chart. Flight technical error and workload are lower, situational awareness is equivalent with conventional paper charts.

  16. Copper link evaluations/solutions for fiber channel, SSA, SONET, ATM, and other services through 4 Gb/sec: basic information, test results, and evaluation

    NASA Astrophysics Data System (ADS)

    Leib, Michael J.

    1995-10-01

    Technitrol, the original designer of MIL-STD-1553 transformers, the original military 1Mb/s LAN, has advanced the state of the art one further notch, introducing a series of transceivers that allow high speed (through 1 Gb/s) data transmission over copper wire instead of fiber optic cable. One such device can be employed to implement the Fiber Channel Interface as defined by hte X3T11 ANSI Fibre Channel Committee using either mini coax, Type 1 shielded twisted pair, twinax or video cable. The technology now exists to upgrade data transmission rates on current physical media to speeds formerly only available with fiber optic cabling. Copper transceiver technology provides a cost effective alternative for dealing with demanding high speed applications such as high speed serial data transfer, high speed disk and tape storage transfer, imaging telemetry, radar, and other avionics applications. Eye diagrams will be presented to show that excellent data transmission at rates of 1 gigabit/sec with low jitter is capable over mini coax at distances to approximately 50 meters, shielded twisted pair and twinax cable to distances of 105 meters, and video cable to distances of 175 meters. Distances are further at lower data rates. As a member of the X3T11 ANSI Fiber Channel Committee, Technitrol has developed a Physical Media (copper wire) Dependant (PMD) transceiver not only compliant with the Fibre Channel Specifications but exceeding the specifications by a factor greater than four. Conceivably, this opens high speed interconnections for today's high data rate requirements to copper cabling systems. Fibre Optic problems need not be dealt with to obtain data transfers for high speed information transfers.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, C A; Clarke, S D; Pozzi, S A

    Purpose: To develop an instrument for measuring neutron and photon dose rates from mixed fields with a single device. Methods: Stilbene organic scintillators can be used to detect fast neutrons and photons. Stilbene was used to measure emission from mixed particle sources californium-252 (Cf-252) and plutonium-beryllium (PuBe). Many source detector configurations were used, along with varying amounts of shielding. Collected spectra were analyzed using pulse shape discrimination software, to separate neutron and photon interactions. With a measured light output to energy relationship the pulse height spectrum was converted to energy deposited in the detector. Energy deposited was converted to dosemore » with a variety of standard dose factors, for comparison to current methods. For validation, all measurements and processing was repeated using an EJ-309 liquid scintillator detector. Dose rates were also measured in the same configuration with commercially available dose meters for further validation. Results: Measurements of dose rates will show agreement across all methods. Higher accuracy of pulse shape discrimination at lower energies with stilbene leads to more accurate measurement of neutron and photon deposited dose. In strong fields of mixed particles discrimination can be performed well at a very low energy threshold. This shows accurate dose measurements over a large range of incident particle energy. Conclusion: Stilbene shows promise as a material for dose rate measurements due to its strong ability for separating neutrons and photon pulses and agreement with current methods. A dual particle dose meter would simplify methods which are currently limited to the measurement of only one particle type. Future work will investigate the use of a silicon photomultiplier to reduce the size and required voltage of the assembly, for practical use as a handheld survey meter, room monitor, or phantom installation. Funding From the United States Department of Energy and the National Nuclear Security Administration.« less

  18. Development of Ground Water in the Houston District, Texas, 1970-1974

    USGS Publications Warehouse

    Gabrysch, R.K.

    1980-01-01

    Total withdrawals of ground water in the Houston district increased 9 percent from about 488 million gallons per day (21.4 cubic meters per second) in 1970 to about 532 million gallons per day (23.3 cubic meters per second) in 1974. The average annual rate of increase from 1960 to 1969 was about 6.3 percent. During 1970-74, increases in pumpage occurred in the Houston, Katy, and NASA areas; decreases occurred in the Pasadena and Alta Lorna areas; and the pumpage in the Baytown-La Porte and Texas City areas remained almost constant.

  19. 4 Gbps impulse radio (IR) ultra-wideband (UWB) transmission over 100 meters multi mode fiber with 4 meters wireless transmission.

    PubMed

    Jensen, Jesper Bevensee; Rodes, Roberto; Caballero, Antonio; Yu, Xianbin; Gibbon, Timothy Braidwood; Monroy, Idelfonso Tafur

    2009-09-14

    We present experimental demonstrations of in-building impulse radio (IR) ultra-wideband (UWB) link consisting of 100 m multi mode fiber (MMF) and 4 m wireless transmission at a record 4 Gbps, and a record 8 m wireless transmission at 2.5 Gbps. A directly modulated vertical cavity surface emitting laser (VCSEL) was used for the generation of the optical signal. 8 m at 2.5 Gbps corresponds to a bit rate--distance product of 20; the highest yet reported for wireless IR-UWB transmission.

  20. Skin-friction measurements by laser interferometry

    NASA Technical Reports Server (NTRS)

    Kim, K.-S.; Settles, G. S.

    1989-01-01

    The measurement of skin friction in rapidly distorted compressible flows is difficult, and very few reliable techniques are available. A recent development, the laser interferometer skin friction (LISF) meter, promises to be useful for this purpose. This technique interferometrically measures the time rate of thinning of an oil film applied to an aerodynamic surface. Under the proper conditions the wall shear stress may thus be found directly, without reference to flow properties. The applicability of the LISF meter to supersonic boundary layers is examined experimentally. Its accuracy and repeatability are assessed, and conditions required for its successful application are considered.

  1. 14 CFR 121.312 - Materials for compartment interiors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... prior to August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in...), except that the total heat release over the first 2 minutes of sample exposure must not exceed 100 kilowatt minutes per square meter and the peak heat release rate must not exceed 100 kilowatts per square...

  2. 14 CFR 121.312 - Materials for compartment interiors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... prior to August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in...), except that the total heat release over the first 2 minutes of sample exposure must not exceed 100 kilowatt minutes per square meter and the peak heat release rate must not exceed 100 kilowatts per square...

  3. 14 CFR 121.312 - Materials for compartment interiors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... prior to August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in...), except that the total heat release over the first 2 minutes of sample exposure must not exceed 100 kilowatt minutes per square meter and the peak heat release rate must not exceed 100 kilowatts per square...

  4. 14 CFR 135.170 - Materials for compartment interiors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in effect March 6, 1995 (formerly § 25.853(a-1) in effect on August 20, 1986), except that the total heat release... and the peak heat release rate must not exceed 100 kilowatts per square meter. (ii) Each airplane with...

  5. 14 CFR 135.170 - Materials for compartment interiors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in effect March 6, 1995 (formerly § 25.853(a-1) in effect on August 20, 1986), except that the total heat release... and the peak heat release rate must not exceed 100 kilowatts per square meter. (ii) Each airplane with...

  6. 14 CFR 121.312 - Materials for compartment interiors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... prior to August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in...), except that the total heat release over the first 2 minutes of sample exposure must not exceed 100 kilowatt minutes per square meter and the peak heat release rate must not exceed 100 kilowatts per square...

  7. 14 CFR 135.170 - Materials for compartment interiors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in effect March 6, 1995 (formerly § 25.853(a-1) in effect on August 20, 1986), except that the total heat release... and the peak heat release rate must not exceed 100 kilowatts per square meter. (ii) Each airplane with...

  8. 14 CFR 135.170 - Materials for compartment interiors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in effect March 6, 1995 (formerly § 25.853(a-1) in effect on August 20, 1986), except that the total heat release... and the peak heat release rate must not exceed 100 kilowatts per square meter. (ii) Each airplane with...

  9. 14 CFR 121.312 - Materials for compartment interiors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... prior to August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in...), except that the total heat release over the first 2 minutes of sample exposure must not exceed 100 kilowatt minutes per square meter and the peak heat release rate must not exceed 100 kilowatts per square...

  10. 14 CFR 135.170 - Materials for compartment interiors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... August 20, 1990, must comply with the heat release rate testing provisions of § 25.853(d) in effect March 6, 1995 (formerly § 25.853(a-1) in effect on August 20, 1986), except that the total heat release... and the peak heat release rate must not exceed 100 kilowatts per square meter. (ii) Each airplane with...

  11. Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2009-01-13

    In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less

  12. Shock absorber operates over wide range

    NASA Technical Reports Server (NTRS)

    Creasy, W. K.; Jones, J. C.

    1965-01-01

    Piston-type hydraulic shock absorber, with a metered damping system, operates over a wide range of kinetic energy loading rates. It is used for absorbing shock and vibration on mounted machinery and heavy earth-moving equipment.

  13. Pine Island Bay

    Atmospheric Science Data Center

    2013-04-16

    ... Birth of a Large Iceberg in Pine Island Bay, Antarctica     View Larger Image ... revealed the crack to be propagating through the shelf ice at a rate averaging 15 meters per day, accompanied by a slight rotation of ...

  14. Subpart W: National Emission Standards for Radon Emissions From Operating Mill Tailings

    EPA Pesticide Factsheets

    Subpart W limits the radon-222 emissions rate from uranium tailings piles to 20 picocuries per square meter per second and requires that new tailings impoundments meet certain work practice standards.

  15. Migrating and Static Sand Ripples on Mars

    NASA Image and Video Library

    2013-08-28

    This observation from NASA Mars Reconnaissance Orbiter is of one many that highlights new discoveries; one of these is that many sand dunes and ripples are moving, some at rates of several meters per year.

  16. Validation of tablet-based evaluation of color fundus images

    PubMed Central

    Christopher, Mark; Moga, Daniela C.; Russell, Stephen R.; Folk, James C.; Scheetz, Todd; Abràmoff, Michael D.

    2012-01-01

    Purpose To compare diabetic retinopathy (DR) referral recommendations made by viewing fundus images using a tablet computer to recommendations made using a standard desktop display. Methods A tablet computer (iPad) and a desktop PC with a high-definition color display were compared. For each platform, two retinal specialists independently rated 1200 color fundus images from patients at risk for DR using an annotation program, Truthseeker. The specialists determined whether each image had referable DR, and also how urgently each patient should be referred for medical examination. Graders viewed and rated the randomly presented images independently and were masked to their ratings on the alternative platform. Tablet- and desktop display-based referral ratings were compared using cross-platform, intra-observer kappa as the primary outcome measure. Additionally, inter-observer kappa, sensitivity, specificity, and area under ROC (AUC) were determined. Results A high level of cross-platform, intra-observer agreement was found for the DR referral ratings between the platforms (κ=0.778), and for the two graders, (κ=0.812). Inter-observer agreement was similar for the two platforms (κ=0.544 and κ=0.625 for tablet and desktop, respectively). The tablet-based ratings achieved a sensitivity of 0.848, a specificity of 0.987, and an AUC of 0.950 compared to desktop display-based ratings. Conclusions In this pilot study, tablet-based rating of color fundus images for subjects at risk for DR was consistent with desktop display-based rating. These results indicate that tablet computers can be reliably used for clinical evaluation of fundus images for DR. PMID:22495326

  17. Mountains, Craters and Plains

    NASA Image and Video Library

    2016-03-17

    New Horizons views of the informally named Sputnik Planum on Pluto (top) and the informally named Vulcan Planum on Charon (bottom). Both scale bars measure 20 miles (32 kilometers) long; illumination is from the left in both instances. The Sputnik Planum view is centered at 11°N, 180°E, and covers the bright, icy, geologically cellular plains. Here, the cells are defined by a network of interconnected troughs that crisscross these nitrogen-ice plains. At right, in the upper image, the cellular plains yield to pitted plains of southern Sputnik Planum. This observation was obtained by the Ralph/Multispectral Visible Imaging Camera (MVIC) at a resolution of 1,050 feet (320 meters) per pixel. The Vulcan Planum view in the bottom panel is centered at 4°S, 4°E, and includes the "moated mountain" Clarke Mons just above the center of the image. As well as featuring impact craters and sinuous troughs, the water ice-rich plains display a range of surface textures, from smooth and grooved at left, to pitted and hummocky at right. This observation was obtained by the Long Range Reconnaissance Imager (LORRI) at a resolution of 525 feet (160 meters) per pixel. http://photojournal.jpl.nasa.gov/catalog/PIA20535

  18. Office of Space Flight standard spaceborne Global Positioning System user equipment project

    NASA Technical Reports Server (NTRS)

    Saunders, Penny E.

    1991-01-01

    The Global Positioning System (GPS) provides users autonomous, real-time navigation capability. A vehicle equipped with GPS user equipment can receive and process signals transmitted by a constellation of GPS satellites and derive from the resulting measurements the vehicle's position and velocity. Specified accuracies range from 16 to 76 meters and 0.1 to 1.0 meters/second for position and velocity, respectively. In a rendezvous and docking scenario, the use of a technique called relative GPS can provide range and range rate accuracies on the order of 1 meter and 0.01 meters/second, respectively. Relative GPS requires both vehicles to be equipped with GPS user equipment and a data communication link for transmission of GPS data and GPS satellite selection coordination information. Through coordinated satellite selection, GPS measurement errors common to both users are cancelled and improved relative position and velocity accuracies are achieved. The background, the design approach, the expected performance and capabilities, the development plan, and the project status are described. In addition, a description of relative GPS, the possible GPS hardware and software configurations, and its application to automated rendezvous and capture are presented.

  19. The Space Operations Simulation Center (SOSC) and Closed-loop Hardware Testing for Orion Rendezvous System Design

    NASA Technical Reports Server (NTRS)

    D'Souza, Christopher; Milenkovich, Zoran; Wilson, Zachary; Huich, David; Bendle, John; Kibler, Angela

    2011-01-01

    The Space Operations Simulation Center (SOSC) at the Lockheed Martin (LM) Waterton Campus in Littleton, Colorado is a dynamic test environment focused on Autonomous Rendezvous and Docking (AR&D) development testing and risk reduction activities. The SOSC supports multiple program pursuits and accommodates testing Guidance, Navigation, and Control (GN&C) algorithms for relative navigation, hardware testing and characterization, as well as software and test process development. The SOSC consists of a high bay (60 meters long by 15.2 meters wide by 15.2 meters tall) with dual six degree-of-freedom (6DOF) motion simulators and a single fixed base 6DOF robot. The large testing area (maximum sensor-to-target effective range of 60 meters) allows for large-scale, flight-like simulations of proximity maneuvers and docking events. The facility also has two apertures for access to external extended-range outdoor target test operations. In addition, the facility contains four Mission Operations Centers (MOCs) with connectivity to dual high bay control rooms and a data/video interface room. The high bay is rated at Class 300,000 (. 0.5 m maximum particles/m3) cleanliness and includes orbital lighting simulation capabilities.

  20. A simulation evaluation of the engine monitoring and control system display

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.

    1990-01-01

    The Engine Monitoring and Control System (E-MACS) display is a new concept for an engine instrument display, the purpose of which is to provide an enhanced means for a pilot to control and monitor aircraft engine performance. It provides graphically-presented information about performance capabilities, current performance, and engine component or subsystem operational conditions relative to nominal conditions. The concept was evaluated by sixteen pilot-subjects against a traditional, state-of-the-art electronic engine display format. The results of this evaluation showed a substantial pilot preference for the E-MACS display relative to the traditional display. The results of the failure detection portion of the evaluation showed a 100 percent detection rate for the E-MACS display relative to a 57 percent rate for the traditional display. From these results, it is concluded that by providing this type of information in the cockpit, a reduction in pilot workload and an enhanced ability for detecting degraded or off-nominal conditions is probable, thus leading to an increase in operational safety.

  1. Service without a smile: comparing the consequences of neutral and positive display rules.

    PubMed

    Trougakos, John P; Jackson, Christine L; Beal, Daniel J

    2011-03-01

    We used an experimental design to examine the intrapersonal and interpersonal processes through which neutral display rules, compared to positive display rules, influence objective task performance of poll workers and ratings provided by survey respondents of the poll workers. Student participants (N = 140) were trained to adhere to 1 of the 2 display rule conditions while delivering opinion surveys to potential patrons of an organization during a 40-min period. Results showed that, compared to positive display rules, neutral display rules resulted in less task persistence and greater avoidance behavior. These effects were mediated through a greater use of expression suppression. In addition, neutral display rules resulted in less positive respondent mood, which accounted for lower ratings of service quality and of overall favorability attitudes toward the sponsoring organization. The importance and ubiquity of neutral display rules are discussed, given the potential for positive and negative consequences at work. PsycINFO Database Record (c) 2011 APA, all rights reserved.

  2. Controlling Motion Sickness and Spatial Disorientation and Enhancing Vestibular Rehabilitation with a User-Worn See-Through Display

    PubMed Central

    Krueger, Wesley W.O.

    2010-01-01

    Objectives/Hypotheses An eyewear mounted visual display (“User-worn see-through display”) projecting an artificial horizon aligned with the user's head and body position in space can prevent or lessen motion sickness in susceptible individuals when in a motion provocative environment as well as aid patients undergoing vestibular rehabilitation. In this project, a wearable display device, including software technology and hardware, was developed and a phase I feasibility study and phase II clinical trial for safety and efficacy were performed. Study Design Both phase I and phase II were prospective studies funded by the NIH. The phase II study used repeated measures for motion intolerant subjects and a randomized control group (display device/no display device) pre-post test design for patients in vestibular rehabilitation. Methods Following technology and display device development, 75 patients were evaluated by test and rating scales in the phase II study; 25 subjects with motion intolerance used the technology in the display device in provocative environments and completed subjective rating scales while 50 patients were evaluated before and after vestibular rehabilitation (25 using the display device and 25 in a control group) using established test measures. Results All patients with motion intolerance rated the technology as helpful for nine symptoms assessed, and 96% rated the display device as simple and easy to use. Duration of symptoms significantly decreased with use of the technology displayed. In patients undergoing vestibular rehabilitation, there were no significant differences in amount of change from pre- to post-therapy on objective balance tests between display device users and controls. However, those using the technology required significantly fewer rehabilitation sessions to achieve those outcomes than the control group. Conclusions A user-worn see-through display, utilizing a visual fixation target coupled with a stable artificial horizon and aligned with user movement, has demonstrated substantial benefit for individuals susceptible to motion intolerance and spatial disorientation and those undergoing vestibular rehabilitation. The technology developed has applications in any environment where motion sensitivity affects human performance. PMID:21181963

  3. Improved fibrosis staging by elastometry and blood test in chronic hepatitis C.

    PubMed

    Calès, Paul; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Hubert, Isabelle; Hunault, Gilles; de Lédinghen, Victor; Zarski, Jean-Pierre; Salmon, Dominique; Lunel, Françoise

    2014-07-01

    Our main objective was to improve non-invasive fibrosis staging accuracy by resolving the limits of previous methods via new test combinations. Our secondary objectives were to improve staging precision, by developing a detailed fibrosis classification, and reliability (personalized accuracy) determination. All patients (729) included in the derivation population had chronic hepatitis C, liver biopsy, 6 blood tests and Fibroscan. Validation populations included 1584 patients. The most accurate combination was provided by using most markers of FibroMeter and Fibroscan results targeted for significant fibrosis, i.e. 'E-FibroMeter'. Its classification accuracy (91.7%) and precision (assessed by F difference with Metavir: 0.62 ± 0.57) were better than those of FibroMeter (84.1%, P < 0.001; 0.72 ± 0.57, P < 0.001), Fibroscan (88.2%, P = 0.011; 0.68 ± 0.57, P = 0.020), and a previous CSF-SF classification of FibroMeter + Fibroscan (86.7%, P < 0.001; 0.65 ± 0.57, P = 0.044). The accuracy for fibrosis absence (F0) was increased, e.g. from 16.0% with Fibroscan to 75.0% with E-FibroMeter (P < 0.001). Cirrhosis sensitivity was improved, e.g. E-FibroMeter: 92.7% vs. Fibroscan: 83.3%, P = 0.004. The combination improved reliability by deleting unreliable results (accuracy <50%) observed with a single test (1.2% of patients) and increasing optimal reliability (accuracy ≥85%) from 80.4% of patients with Fibroscan (accuracy: 90.9%) to 94.2% of patients with E-FibroMeter (accuracy: 92.9%), P < 0.001. The patient rate with 100% predictive values for cirrhosis by the best combination was twice (36.2%) that of the best single test (FibroMeter: 16.2%, P < 0.001). The new test combination increased: accuracy, globally and especially in patients without fibrosis, staging precision, cirrhosis prediction, and even reliability, thus offering improved fibrosis staging. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Interspecific variation in SO/sub 2/ flux: leaf surface versus internal flux, and components of leaf conductance. [Pisum sativum L. , Lycopersicon esculentum Mill. Flacca, Geranium carolinianum L. , Diplacus aurantiacus (Curtis) Jeps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olszyk, D.M.; Tingey, D.T.

    The objective of this study was to clarify the relationships among stomatal, residual, and epidermal conductances in determining the flux of SO/sub 2/ air pollution to leaves. Variations in leaf SO/sub 2/ and H/sub 2/O vapor fluxes were determined using four plant species: Pisum sativum L. (garden pea), Lycopersicon esculentum Mill. flacca (mutant of tomato), Geranium carolinianum L. (wild geranium), and Diplacus aurantiacus (Curtis) Jeps. (a native California shrub). Fluxes were measured using the mass-balance approach during exposure to 4.56 micromoles per cubic meter (0.11 microliters per liter) SO/sub 2/ for 2 hours in a controlled environmental chamber. Flux throughmore » adaxial and abaxial leaf surfaces with closed stomata ranged from 1.9 to 9.4 nanomoles per square meter per second for SO/sub 2/, and 0.3 to 1.3 millimoles per square meter per second for H/sub 2/O vapor. Flux of SO/sub 2/ into leaves through stomata ranged from approx.0 to 8.5 (dark) and 3.8 to 16.0 (light) millimoles per square meter per second. Flux of H/sub 2/O vapor from leaves through stomata ranged from approx.0 to 0.6 (dark) to 0.4 to 0.9 (light) millimole per square meter per second. Lycopersicon had internal flux rates for both SO/sub 2/ and H/sub 2/O vapor over twice as high as for the other species. Stomatal conductance based on H/sub 2/O vapor flux averaged from 0.07 to 0.13 mole per square meter per second among the four species. Internal conductance of SO/sub 2/ as calculated from SO/sub 2/ flux was from 0.04 mole per square meter per second lower to 0.06 mole per square meter per second higher than stomatal conductance. For Pisum, Geranium, and Diplacus stomatal conductance was the same or slightly higher than internal conductance, indicating that, in general, SO/sub 2/ flux could be predicted from stomatal conductance for H/sub 2/O vapor.« less

  5. Carotenoids as protection against disability in older persons.

    PubMed

    Lauretani, Fulvio; Semba, Richard D; Bandinelli, Stefania; Dayhoff-Brannigan, Margaret; Lauretani, Fabrizio; Corsi, Anna Maria; Guralnik, Jack M; Ferrucci, Luigi

    2008-06-01

    The purpose was to examine the relationship of total plasma carotenoids, an indicator of fruit and vegetable intake, with walking speed and severe walking disability in older adults. Nine hundred twenty-eight men and women aged 65 to 102 years from the Invecchiare in Chianti (Aging in the Chianti Area [InCHIANTI]) study, a population-based cohort in Tuscany, Italy, were studied. Plasma carotenoids were measured at enrollment (1998-2000), and walking speed over 4 meters and 400 meters distance were assessed at enrollment and 6 years later (2004-2006). At enrollment, 85 of 928 (9.2%) participants had severe walking disability (defined as being unable to walk or having a walking speed at the 4-meter walking test < 0.4 m/sec). After adjusting for potential confounders, participants with high total plasma carotenoids were significantly less likely to have prevalent severe walking disability (odds ration [OR] 0.59, 95% confidence interval [CI] 0.38-0.90, p = 0.01) and had higher walking speed over 4 meters (beta = 0.024, standard error [SE] = 0.011, p = 0.03) and over 400 meters (beta = 0.019, SE = 0.010, p = 0.04). Of 621 participants without severe walking disability at enrollment who were seen 6 years later, 68 (11.0%) developed severe walking disability. After adjusting for potential confounders, higher total plasma carotenoids were associated with a significantly lower risk of developing severe walking disability (OR 0.51, 95% CI 0.30-0.86, p = 0.01) and were associated with a less steep decline in 4-meter walking speed over a 6-year follow-up (n = 579; beta = 0.026, SE = 0.012, p = 0.03) and with lower incidence rates of being unable to successfully complete the 400-meter walking test at the 6-year follow-up visit (beta = -0.054, SE = 0.03, p = 0.04). High plasma carotenoids concentrations may be protective against the decline in walking speed and the development of severe walking disability in older adults.

  6. Volatile organic compounds and good laboratory practices in the in vitro fertilization laboratory: the important parameters for successful outcome in extended culture.

    PubMed

    Agarwal, Nupur; Chattopadhyay, Ratna; Ghosh, Sanghamitra; Bhoumik, Arpita; Goswami, S K; Chakravarty, Baidyanath

    2017-08-01

    This study aims to describe the role of implementing good laboratory practices to improve in vitro fertilization (IVF) outcomes which are of great interest for practitioners dealing with infertility. Certain modifications were introduced in May 2015 in our IVF laboratory like high-efficiency particulate air CODA system, steel furniture instead of wooden, use of new disinfectants like oosafe, and restriction of personnel entry along with avoidance of cosmetics like perfume to improve pregnancy rates. Volatile organic compound (VOC) meter reading was monitored at two time points and five different places in the laboratory to compare the embryonic development parameters before (group A: July 2014-April 2015) and after (group B: July 2015-April 2016) remodeling. The IVF outcomes from 1036 cycles were associated in this study. Reduction in VOC meter readings, enhanced air quality, improvement in blastocyst formation rate, implantation, and clinical pregnancy rate were observed in the laboratory after implementation of new facilities. Results illustrated that the attention must be focused on potential hazards which expose laboratories to elevated VOC levels. Blastocyst formation rate increased around 18%. Implantation rate, clinical pregnancy rate, and live birth rate increased by around 11, 10, and 8%, respectively. In conclusion, with proper engineering and material selection, we have been able to reduce chemical contamination and adverse effects on culture with optimized IVF results. None.

  7. Water, ice, and meteorological measurements at South Cascade glacier, Washington, balance year 2003

    USGS Publications Warehouse

    Bidlake, William R.; Josberger, Edward G.; Savoca, Mark E.

    2005-01-01

    Winter snow accumulation and summer snow and ice ablation were measured at South Cascade Glacier, Washington, to estimate glacier mass-balance quantities for balance year 2003. The 2003 glacier-average maximum winter snow balance was 2.66 meters water equivalent, which was about equal to the average of such balances for the glacier since balance year 1959. The 2003 glacier summer balance (-4.76 meters water equivalent) was the most negative reported for the glacier, and the 2003 net balance (-2.10 meters water equivalent), was the second-most negative reported. The glacier 2003 annual (water year) balance was -1.89 meters water equivalent. The area of the glacier near the end of the balance year was 1.89 square kilometers, a decrease of 0.03 square kilometer from the previous year. The equilibrium-line altitude was higher than any part of the glacier; however, because snow remained along part of one side of the upper glacier, the accumulation-area ratio was 0.07. During September 13, 2002-September 13, 2003, the glacier terminus retreated at a rate of about 15 meters per year. Average speed of surface ice, computed using a series of vertical aerial photographs dating back to 2001, ranged from 2.2 to 21.8 meters per year. Runoff from the subbasin containing the glacier and from an adjacent non-glacierized basin was gaged during part of water year 2003. Air temperature, precipitation, atmospheric water-vapor pressure, wind speed, and incoming solar radiation were measured at selected locations on and near the glacier. Summer 2003 at the glacier was among the warmest for which data are available.

  8. Water Relations, Diurnal Acidity Changes, and Productivity of a Cultivated Cactus, Opuntia ficus-indica.

    PubMed

    Acevedo, E; Badilla, I; Nobel, P S

    1983-07-01

    Physiological responses of the Crassulacean acid metabolism (CAM) plant Opuntia ficus-indica (Cactaceae) were studied on a commercial plantation in central Chile. Young cladodes (flattened stems) and flower buds exhibited daytime stomatal opening, whereas mature cladodes and fruit exhibited the nocturnal stomatal opening characteristic of CAM plants. Severe water stress suppressed the nocturnal stomatal opening by mature cladodes, but their high water vapor conductance occurring near dawn was not affected. Nocturnal acidity increases were not as sensitive to water stress as was the nocturnal stomatal opening. The magnitude of the nocturnal acidity increases depended on the total daily photosynthetically active radiation (PAR), being 90% PAR-saturated at 27 moles per square meter per day for a mean nighttime air temperature of 5 degrees C and at 20 moles per square meter per day for 18 degrees C. Inasmuch as the PAR received on unshaded vertical surfaces averaged about 21 moles per square meter per day, nocturnal acidity increases by the cladodes were on the verge of being PAR-limited in the field. The net assimilation rate, which was positive throughout the year, annually averaged 3.4 grams per square meter per day for 1.0- and 2.0-year-old plants. Plants that were 5.4 years old had 7.2 square meters of cladode surface area (both sides) and an annual dry weight productivity of 13 megagrams (metric tons) per hectare per year when their ground cover was 32%. This substantial productivity for a CAM plant was accompanied by the highest nocturnal acidity increase so far observed in the field, 0.78 mole H(+) per square meter.

  9. Water Relations, Diurnal Acidity Changes, and Productivity of a Cultivated Cactus, Opuntia ficus-indica1

    PubMed Central

    Acevedo, Edmundo; Badilla, Ignacio; Nobel, Park S.

    1983-01-01

    Physiological responses of the Crassulacean acid metabolism (CAM) plant Opuntia ficus-indica (Cactaceae) were studied on a commercial plantation in central Chile. Young cladodes (flattened stems) and flower buds exhibited daytime stomatal opening, whereas mature cladodes and fruit exhibited the nocturnal stomatal opening characteristic of CAM plants. Severe water stress suppressed the nocturnal stomatal opening by mature cladodes, but their high water vapor conductance occurring near dawn was not affected. Nocturnal acidity increases were not as sensitive to water stress as was the nocturnal stomatal opening. The magnitude of the nocturnal acidity increases depended on the total daily photosynthetically active radiation (PAR), being 90% PAR-saturated at 27 moles per square meter per day for a mean nighttime air temperature of 5°C and at 20 moles per square meter per day for 18°C. Inasmuch as the PAR received on unshaded vertical surfaces averaged about 21 moles per square meter per day, nocturnal acidity increases by the cladodes were on the verge of being PAR-limited in the field. The net assimilation rate, which was positive throughout the year, annually averaged 3.4 grams per square meter per day for 1.0- and 2.0-year-old plants. Plants that were 5.4 years old had 7.2 square meters of cladode surface area (both sides) and an annual dry weight productivity of 13 megagrams (metric tons) per hectare per year when their ground cover was 32%. This substantial productivity for a CAM plant was accompanied by the highest nocturnal acidity increase so far observed in the field, 0.78 mole H+ per square meter. PMID:16663084

  10. A direct passive method for measuring water and contaminant fluxes in porous media

    NASA Astrophysics Data System (ADS)

    Hatfield, Kirk; Annable, Michael; Cho, Jaehyun; Rao, P. S. C.; Klammler, Harald

    2004-12-01

    This paper introduces a new direct method for measuring water and contaminant fluxes in porous media. The method uses a passive flux meter (PFM), which is essentially a self-contained permeable unit properly sized to fit tightly in a screened well or boring. The meter is designed to accommodate a mixed medium of hydrophobic and/or hydrophilic permeable sorbents, which retain dissolved organic/inorganic contaminants present in the groundwater flowing passively through the meter. The contaminant mass intercepted and retained on the sorbent is used to quantify cumulative contaminant mass flux. The sorptive matrix is also impregnated with known amounts of one or more water soluble 'resident tracers'. These tracers are displaced from the sorbent at rates proportional to the groundwater flux; hence, in the current meter design, the resident tracers are used to quantify cumulative groundwater flux. Theory is presented and quantitative tools are developed to interpret the water flux from tracers possessing linear and nonlinear elution profiles. The same theory is extended to derive functional relationships useful for quantifying cumulative contaminant mass flux. To validate theory and demonstrate the passive flux meter, results of multiple box-aquifer experiments are presented and discussed. From these experiments, it is seen that accurate water flux measurements are obtained when the tracer used in calculations resides in the meter at levels representing 20 to 70 percent of the initial condition. 2,4-Dimethyl-3-pentanol (DMP) is used as a surrogate groundwater contaminant in the box aquifer experiments. Cumulative DMP fluxes are measured within 5% of known fluxes. The accuracy of these estimates generally increases with the total volume of water intercepted.

  11. Field evaluation of boat-mounted acoustic Doppler instruments used to measure streamflow

    USGS Publications Warehouse

    Mueller, D.S.; ,

    2003-01-01

    The use of instruments based on the Doppler principle for measuring water velocity and computing discharge is common within the U.S. Geological Survey (USGS). The instruments and software have changed appreciably during the last 5 years; therefore, the USGS has begun field validation of the instruments used to make discharge measurements from a moving boat. Instruments manufactured by SonTek/YSI and RD Instruments, Inc. were used to collect discharge data at five different sites. One or more traditional discharge measurements were made using a Price AA current meter and standard USGS procedures concurrent with the acoustic instruments at each site. Discharges measured with the acoustic instruments were compared with discharges measured with Price AA current meters and the USGS stage-discharge rating for each site. The mean discharges measured by each acoustic instrument were within 5 percent of the Price AA-based measurement and (or) discharge from the stage-discharge rating.

  12. A rate-controlled teleoperator task with simulated transport delays

    NASA Technical Reports Server (NTRS)

    Pennington, J. E.

    1983-01-01

    A teleoperator-system simulation was used to examine the effects of two control modes (joint-by-joint and resolved-rate), a proximity-display method, and time delays (up to 2 sec) on the control of a five-degree-of-freedom manipulator performing a probe-in-hole alignment task. Four subjects used proportional rotational control and discrete (on-off) translation control with computer-generated visual displays. The proximity display enabled subjects to separate rotational errors from displacement (translation) errors; thus, when the proximity display was used with resolved-rate control, the simulated task was trivial. The time required to perform the simulated task increased linearly with time delay, but time delays had no effect on alignment accuracy. Based on the results of this simulation, several future studies are recommended.

  13. The Fate and Stability of Eroding Wetland Soil Carbon in a Subsiding Deltaic Coastal Plain

    NASA Astrophysics Data System (ADS)

    White, J. R.; Steinmuller, H.; Chambers, L. G.; Fontenot, A.

    2017-12-01

    Coastal wetlands can respond to rapid rates of relative sea level rise via wetland submergence and/or erosion, which occur when wetlands are unable to vertically accrete to keep pace with sea level rise. As coastal wetlands erode, previously sequestered organic carbon is exposed to oxygen-rich estuarine water. This transition in redox from anaerobic to aerobic condition can trigger increased mineralization rates of decades to centuries'-old soil carbon. Barataria Bay, Louisiana has one of the highest coastal wetland land loss rates in the United States, primarily due to eustatic sea level rise coupled with coastal subsidence. Marsh-edge erosion rates measured over the past two years are on the order of 1.5 meters per year. Meter long soil cores were obtained from vegetated wetland sites and sectioned into 11 intervals to investigate aerobic and anaerobic mineralization rates with depth. In surface soils, organic carbon mineralization rates averaged 16 times greater than anaerobic mineralization rates. In deeper, older soils, the aerobic mineralization rate was still an order of magnitude greater than the anaerobic rate, suggesting a significant portion of this older, soil carbon is readily cycling back to the atmosphere after erosion followed by mineralization by microorganisms. These results have consequences for increased atmospheric CO2 concentrations in the future, as stable coastlines worldwide will be subjected to Barataria-bay levels of sea level rise in the next 50-75 years.

  14. Two dimensional eye tracking: Sampling rate of forcing function

    NASA Technical Reports Server (NTRS)

    Hornseth, J. P.; Monk, D. L.; Porterfield, J. L.; Mcmurry, R. L.

    1978-01-01

    A study was conducted to determine the minimum update rate of a forcing function display required for the operator to approximate the tracking performance obtained on a continuous display. In this study, frequency analysis was used to determine whether there was an associated change in the transfer function characteristics of the operator. It was expected that as the forcing function display update rate was reduced, from 120 to 15 samples per second, the operator's response to the high frequency components of the forcing function would show a decrease in gain, an increase in phase lag, and a decrease in coherence.

  15. Water tight.

    PubMed

    Postel, S

    1993-01-01

    Many cities worldwide have gone beyond the limits of their water supply. Growing urban populations increase their demand for water, thereby straining local water supplies and requiring engineers to seek our even more distant water sources. It is costly to build and maintain reservoirs, canals, pumping stations, pipes, sewers, and treatment plants. Water supply activities require much energy and chemicals, thereby contributing to environmental pollution. Many cities are beginning to manage the water supply rather than trying to keep up with demand. Pumping ground water for Mexico City's 18 million residents (500,000 people added/year) surpasses natural replenishment by 50% to 80%, resulting in falling water tables and compressed aquifers. Mexico City now ambitiously promotes replacement of conventional toilets with 1.6 gallon toilets (by late 1991, this had saved almost 7.4 billion gallons of water/year). Continued high rural-urban migration and high birth rates could negate any savings, however. Waterloo, Ontario, has also used conservation efforts to manage water demand. These efforts include retrofit kits to make plumbing fixtures more efficient, efficiency standards for plumbing fixtures, and reduction of water use outdoors. San Jose, California, has distributed water savings devices to about 220,000 households with a 90% cooperation rate. Boston, Massachusetts, not only promoted water saving devices but also repaired leaks and had an information campaign. Increasing water rates to actually reflect true costs also leads to water conservation, but not all cities in developing countries use water meters. All households in Edmonton, Alberta, are metered and its water use is 1/2 of that of Calgary, where only some households are metered. Tucson, Arizona, reduced per capita water use 16% by raising water rates and curbing water use on hot days. Bogor, Indonesia, reduced water use almost 30% by increasing water rates. In the US, more and more states are mandating use of water-efficient plumbing fixtures. Multilateral development agencies have identified some developing country cities as demonstrated sites for urban water conservation.

  16. Studies on hand-held visual communication device for the deaf and speech-impaired I. Visual display window size.

    PubMed

    Thurlow, W R

    1980-01-01

    Messages were presented which moved from right to left along an electronic alphabetic display which was varied in "window" size from 4 through 32 letter spaces. Deaf subjects signed the messages they perceived. Relatively few errors were made even at the highest rate of presentation, which corresponded to a typing rate of 60 words/min. It is concluded that many deaf persons can make effective use of a small visual display. A reduced cost is then possible for visual communication instruments for these people through reduced display size. Deaf subjects who can profit from a small display can be located by a sentence test administered by tape recorder which drives the display of the communication device by means of the standard code of the deaf teletype network.

  17. Display Rules for Anger and Aggression in School-Age Children.

    ERIC Educational Resources Information Center

    Underwood, Marion K.; And Others

    1992-01-01

    Two studies examined the development of display rules for anger and the relationship between the use of display rules for anger and aggressiveness as rated by school peers. Findings indicate that the phenomenon of display rules for anger is complex and depends on the way display rules are defined and the age and gender of the subjects. (GLR)

  18. An evaluation of welding processes to reduce hexavalent chromium exposures and reduce costs by using better welding techniques.

    PubMed

    Keane, Michael J

    2014-01-01

    A group of stainless steel arc welding processes was compared for emission rates of fume and hexavalent chromium, and costs per meter length of weld. The objective was to identify those with minimal emissions and also compare relative labor and consumables costs. The selection included flux-cored arc welding (FCAW), shielded-metal arc welding (SMAW), and multiple gas metal arc welding (GMAW) processes. Using a conical chamber, fumes were collected, and fume generation rates and hexavalent chromium (Cr(6+)) were measured. GMAW processes used were short-circuit (SC) and pulsed-spray modes. Flux-cored welding used gas shielding. Costs were estimated per meter of a 6.3-mm thick horizontal butt weld. Emission rates of Cr(6+) were lowest for GMAW processes and highest for SMAW; several GMAW processes had less than 2% of the SMAW generation rate. Labor and consumable costs for the processes studied were again highest for SMAW, with those of several GMAW types about half that cost. The results show that use of any of the GMAW processes (and flux-cored welding) could substantially reduce fume and Cr(6+) emissions, and greatly reduce costs relative to SMAW.

  19. An Evaluation of Welding Processes to Reduce Hexavalent Chromium Exposures and Reduce Costs by Using Better Welding Techniques

    PubMed Central

    Keane, Michael J

    2014-01-01

    A group of stainless steel arc welding processes was compared for emission rates of fume and hexavalent chromium, and costs per meter length of weld. The objective was to identify those with minimal emissions and also compare relative labor and consumables costs. The selection included flux-cored arc welding (FCAW), shielded-metal arc welding (SMAW), and multiple gas metal arc welding (GMAW) processes. Using a conical chamber, fumes were collected, and fume generation rates and hexavalent chromium (Cr6+) were measured. GMAW processes used were short-circuit (SC) and pulsed-spray modes. Flux-cored welding used gas shielding. Costs were estimated per meter of a 6.3-mm thick horizontal butt weld. Emission rates of Cr6+ were lowest for GMAW processes and highest for SMAW; several GMAW processes had less than 2% of the SMAW generation rate. Labor and consumable costs for the processes studied were again highest for SMAW, with those of several GMAW types about half that cost. The results show that use of any of the GMAW processes (and flux-cored welding) could substantially reduce fume and Cr6+ emissions, and greatly reduce costs relative to SMAW. PMID:25574138

  20. Techniques for optimizing human-machine information transfer related to real-time interactive display systems

    NASA Technical Reports Server (NTRS)

    Granaas, Michael M.; Rhea, Donald C.

    1989-01-01

    The requirements for the development of real-time displays are reviewed. Of particular interest are the psychological aspects of design such as the layout, color selection, real-time response rate, and the interactivity of displays. Some existing Western Aeronautical Test Range displays are analyzed.

Top