Arbitrating Control of Control and Display Units
NASA Technical Reports Server (NTRS)
Sugden, Paul C.
2007-01-01
The ARINC 739 Switch is a computer program that arbitrates control of two multi-function control and display units (MCDUs) between (1) a commercial flight-management computer (FMC) and (2) NASA software used in research on transport aircraft. (MCDUs are the primary interfaces between pilots and FMCs on many commercial aircraft.) This program was recently redesigned into a software library that can be embedded in research application programs. As part of the redesign, this software was combined with software for creating custom pages of information to be displayed on a CDU. This software commands independent switching of the left (pilot s) and right (copilot s) MCDUs. For example, a custom CDU page can control the left CDU while the FMC controls the right CDU. The software uses menu keys to switch control of the CDU between the FMC or a custom CDU page. The software provides an interface that enables custom CDU pages to insert keystrokes into the FMC s CDU input interface. This feature allows the custom CDU pages to manipulate the FMC as if it were a pilot.
The Evaluation of Two CDU Concepts and Their Effects on FMS Training
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
1995-01-01
One of the biggest challenges for a pilot in the transition to a "glass" cockpit is understanding the Flight Management System (FMS). This is due to both the complex nature of the FMS and to the pilot-FMS interface. For these reasons, a large portion of transition training is devoted to the FMS. The intent of the current study was to examine the impact of the primary pilot-FMS interface, the Control Display Unit (CDU), on FMS training. The hypothesis of this study was that the interface design could have a significant impact on training. An FMS simulation was developed with two separate interfaces. One interface was similar to a current-generation design and the other was a multi-windows CDU based on graphical user interface techniques. For both application and evaluation reasons, constraints were applied to the graphical CDU design to maintain as much similarity as possible with the conventional CDU.
A Comparison of Two Control Display Unit Concepts on Flight Management System Training
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
1997-01-01
One of the biggest challenges for a pilot in the transition to a 'glass' cockpit is understanding the flight management system (FMS). Because of both the complex nature of the FMS and the pilot-FMS interface, a large portion of transition training is devoted to the FMS. The current study examined the impact of the primary pilot-FMS interface, the control display unit (CDU), on FMS training. Based on the hypothesis that the interface design could have a significant impact on training, an FMS simulation with two separate interfaces was developed. One interface was similar to a current-generation design, and the other was a multiwindows CDU based on graphical user interface techniques. For both application and evaluation reasons, constraints were applied to the graphical CDU design to maintain as much similarity as possible with the conventional CDU. This preliminary experiment was conducted to evaluate the interface effects on training. Sixteen pilots with no FMS experience were used in a between-subjects test. A time-compressed, airline-type FMS training environment was simulated. The subjects were trained to a fixed-time criterion, and performance was measured in a final, full-mission simulation context. This paper describes the technical approach, simulation implementation, and experimental results of this effort.
NASA Technical Reports Server (NTRS)
Crane, J. M.; Boucek, G. P., Jr.; Smith, W. D.
1986-01-01
A flight management computer (FMC) control display unit (CDU) test was conducted to compare two types of input devices: a fixed legend (dedicated) keyboard and a programmable legend (multifunction) keyboard. The task used for comparison was operation of the flight management computer for the Boeing 737-300. The same tasks were performed by twelve pilots on the FMC control display unit configured with a programmable legend keyboard and with the currently used B737-300 dedicated keyboard. Flight simulator work activity levels and input task complexity were varied during each pilot session. Half of the points tested were previously familiar with the B737-300 dedicated keyboard CDU and half had no prior experience with it. The data collected included simulator flight parameters, keystroke time and sequences, and pilot questionnaire responses. A timeline analysis was also used for evaluation of the two keyboard concepts.
Advanced Transport Operating System (ATOPS) control display unit software description
NASA Technical Reports Server (NTRS)
Slominski, Christopher J.; Parks, Mark A.; Debure, Kelly R.; Heaphy, William J.
1992-01-01
The software created for the Control Display Units (CDUs), used for the Advanced Transport Operating Systems (ATOPS) project, on the Transport Systems Research Vehicle (TSRV) is described. Module descriptions are presented in a standardized format which contains module purpose, calling sequence, a detailed description, and global references. The global reference section includes subroutines, functions, and common variables referenced by a particular module. The CDUs, one for the pilot and one for the copilot, are used for flight management purposes. Operations performed with the CDU affects the aircraft's guidance, navigation, and display software.
1978-05-01
navigation computer (SNC), sepa- rate alterable memory units for the computer, a control /display unit (CDU), a computer control unit (CCU), and a non ...AND SYSTEM Advisory Group for Aerospace Research and Development, Paris (France). Presented at the 15th Meeting of the Guidance and Control Panel of... Group , Redondo Beach, Calif.) American Institute of Aeronautics and Astronautics, Guidance and Control Conference, Key Biscayne, Fla., August 20-22
Schull, Michael J; Vermeulen, Marian J; Stukel, Therese A; Guttmann, Astrid; Leaver, Chad A; Rowe, Brian H; Sales, Anne
2012-07-01
To evaluate the effect of emergency department (ED) clinical decision units (CDUs) on overall ED patient flow in a pilot project funded in 2008 by the Ontario Ministry of Health and Long-Term Care (MOHLTC). A retrospective analysis of unscheduled ED visits at seven CDU pilot and nine control sites was conducted using administrative data. The authors examined trends in CDU utilization and compared outcomes between pilot-CDU and control sites 1 year prior to implementation, with the first 18 months of CDU operation. Sites that were unsuccessful in their applications for CDU program funding served as controls. Outcomes included ED length of stay (LOS), admission rates, and ED revisit rates. At CDU sites, roughly 4% of ED patients were admitted to CDUs. The presence of a pilot-CDU was independently associated with a small reduction in ED LOS for all low-acuity patients (-0.14 hour, 95% confidence interval [CI]=-0.22 to -0.07) and nonadmitted patients (-0.11 hour, 95% CI=-0.16 to -0.07). A small independent effect on absolute hospital admission rate for all high-acuity patients (-0.8%, 95% CI=-1.5% to -0.03%) and moderate-acuity patients (-0.6%, 95% CI=-1.1% to -0.2%) was also observed. Pilot-CDUs were not associated with changes in ED revisit rates. With only 4% of ED patients admitted to CDUs, the potential for efficiency gains in these EDs was limited. Nonetheless, these findings suggest small improvements in the operation of the ED through CDU implementation. Although marginal, the observed effects of CDU operation were in the desired direction of reduced ED LOS, reduced admission rate, and no increase in ED revisit rate. © 2012 by the Society for Academic Emergency Medicine.
NASA Technical Reports Server (NTRS)
Ellis, R. C.; Fink, R. A.; Moore, E. A.
1987-01-01
The Common Drive Unit (CDU) is a high reliability rotary actuator with many versatile applications in mechanism designs. The CDU incorporates a set of redundant motor-brake assemblies driving a single output shaft through differential. Tachometers provide speed information in the AC version. Operation of both motors, as compared to the operation of one motor, will yield the same output torque with twice the output speed.
Roberts, Mark Vignesha; Baird, Wendy; Kerr, Paul; O'Reilly, Seamus
2010-04-01
To evaluate a Clinical Decision Unit (CDU) designed to utilize alternatives to emergency hospitalization. CDUs are one model of care designed to strengthen the gatekeeper role of Emergency Departments (EDs). This retrospective cohort study was carried out in a UK NHS acute hospital. All 854 patients in the CDU cohort were compared with three age-stratified, historical cohorts from the same clinical centre. The median age was 62 years (range 16-94).The main outcome measures were discharge to general practitioner, outpatient services or hospitalization, the 30-day unplanned reattendance rate for those not hospitalized, and monthly medical admission figures. Approximately 511 [59.8%, 95% confidence interval (CI): 56.5-63.1%] to 560 (65.6%, 95% CI: 62.3-68.7%) patients were admitted in the comparison cohorts, compared with only 186 (21.8%, 95% CI: 19.1-24.7%) in the CDU cohort (P≤0.05). Approximately 243 (28.5%, 95% CI: 25.5-31.6%) to 289 (33.8%, 95% CI: 30.7-37.1%) patients were discharged to general practitioner services in the comparison groups, compared with 562 (65.8%, 95% CI: 62.6-68.9%) in the CDU group (P≤0.05). Approximately eight (0.9, 95% CI: 0.5-1.8%) to 17 (2%, 95% CI: 1.2-3.2%) patients in the comparison groups were discharged to outpatient clinics, compared with 82 (9.6%, 95% CI: 7.8-11.8%) in the CDU group (P≤0.05). There was no consistent trend towards statistically significant rises in unplanned reattendance (P>0.05). Monthly medical admissions fell substantially during CDU operation. This CDU model was associated with statistically and clinically significant reductions in hospital admissions. The judicious application of this CDU model to other ED environments can be expected to yield similar benefits.
78 FR 3363 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-16
...-mechanical brake flex shaft (short flexshaft) of the thrust reverser actuation system (TRAS). This proposed... the electro-mechanical brake and center drive unit (CDU) cone brake to verify the holding torque, and... describes a functional test of the electro-mechanical brake and CDU cone brake to verify the holding torque...
Magadzire, Bvudzai Priscilla; Marchal, Bruno; Ward, Kim
2015-11-17
The Chronic Dispensing Unit (CDU) is an out-sourced, public sector centralised dispensing service that has been operational in the Western Cape Province in South Africa since 2005. The CDU dispenses medicines for stable patients with chronic conditions. The aim is to reduce pharmacists' workload, reduce patient waiting times and decongest healthcare facilities. Our objectives are to describe the intervention's scope, illustrate its interface with the health system and describe its processes and outcomes. Secondly, to quantify the magnitude of missed appointments by enrolled patients and to describe the implications thereof in order to inform a subsequent in-depth empirical study on the underlying causes. We adopted a case study design in order to elicit the programme theory underlying the CDU strategy. We consulted 15 senior and middle managers from the provincial Department of Health who were working closely with the intervention and the contractor using focus group discussions and key informant interviews. In addition, relevant literature, and policy and programme documents were reviewed and analysed. We found that the CDU scope has significantly expanded over the last 10 years owing to technological advancements. As such, in early 2015, the CDU produced nearly 300,000 parcels monthly. Medicines supply, patient enrollment processes, healthcare professionals' compliance to legislation and policies, mechanisms for medicines distribution, management of non-collected medicines (emanating from patients' missed appointments) and the array of actors involved are all central to the CDU's functioning. Missed appointments by patients are a problem, affecting an estimated 8%-12% of patients each month. However, the causes have not been investigated thoroughly. Implications of missed appointments include a cost to government for services rendered by the contractor, potential losses due to expired medicines, additional workload for the contractor and healthcare facility staff and potential negative therapeutic outcomes for patients. The CDU demonstrates innovation in a context of overwhelming demand for dispensing medicines for chronic conditions. However, it is not a panacea to address access-to-medicines related challenges. A multi-level assessment that is currently underway will provide more insights on how existing challenges can be addressed.
Continuous quality improvement for the clinical decision unit.
Mace, Sharon E
2004-01-01
Clinical decision units (CDUs) are a relatively new and growing area of medicine in which patients undergo rapid evaluation and treatment. Continuous quality improvement (CQI) is important for the establishment and functioning of CDUs. CQI in CDUs has many advantages: better CDU functioning, fulfillment of Joint Commission on Accreditation of Healthcare Organizations mandates, greater efficiency/productivity, increased job satisfaction, better performance improvement, data availability, and benchmarking. Key elements include a database with volume indicators, operational policies, clinical practice protocols (diagnosis specific/condition specific), monitors, benchmarks, and clinical pathways. Examples of these important parameters are given. The CQI process should be individualized for each CDU and hospital.
Developing a performance data suite to facilitate lean improvement in a chemotherapy day unit.
Lingaratnam, Senthil; Murray, Danielle; Carle, Amber; Kirsa, Sue W; Paterson, Rebecca; Rischin, Danny
2013-07-01
A multidisciplinary team from the Peter MacCallum Cancer Centre in Melbourne, Australia, developed a performance data suite to support a service improvement project based on lean manufacturing principles in its 19-chair chemotherapy day unit (CDU) and cytosuite chemotherapy production facility. The aims of the project were to reduce patient wait time and improve equity of access to the CDU. A project team consisting of a pharmacist and CDU nurse supported the management team for 10 months in engaging staff and customers to identify waste in processes, analyze root causes, eliminate non-value-adding steps, reduce variation, and level workloads to improve quality and flow. Process mapping, staff and patient tracking and opinion surveys, medical record audits, and interrogation of electronic treatment records were undertaken. This project delivered a 38% reduction in median wait time on the day (from 32 to 20 minutes; P < .01), 7-day reduction in time to commencement of treatment for patients receiving combined chemoradiotherapy regimens (from 25 to 18 days; P < .01), and 22% reduction in wastage associated with expired drug and pharmacy rework (from 29% to 7%; P < .01). Improvements in efficiency enabled the cytosuite to increase the percentage of product manufactured within 10 minutes of appointment times by 29% (from 47% to 76%; P < .01). A lean improvement methodology provided a robust framework for improved understanding and management of complex system constraints within a CDU, resulting in improved access to treatment and reduced waiting times on the day.
Mask characterization for CDU budget breakdown in advanced EUV lithography
NASA Astrophysics Data System (ADS)
Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho
2012-11-01
As the ITRS Critical Dimension Uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and a high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. In this paper we will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for an advanced EUV lithography with 1D and 2D feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CD's and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples in this paper. Also mask stack reflectivity variations should be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We observed also MEEF-through-field fingerprints in the studied EUV cases. Variations of MEEF may also play a role for the total intrafield CDU and may be taken into account for EUV Lithography. We characterized MEEF-through-field for the reviewed features, the results to be discussed in our paper, but further analysis of this phenomenon is required. This comprehensive approach to characterization of the mask part of EUV CDU characterization delivers an accurate and integral CDU Budget Breakdown per product/process and Litho tool. The better understanding of the entire CDU budget for advanced EUVL nodes achieved by Samsung and ASML helps to extend the limits of Moore's Law and to deliver successful implementation of smaller, faster and smarter chips in semiconductor industry.
NASA Astrophysics Data System (ADS)
Tadokoro, Masahide; Shinozuka, Shinichi; Ogata, Kunie; Morimoto, Tamotsu
2008-03-01
Semiconductor manufacturing technology has shifted towards finer design rules, and demands for critical dimension uniformity (CDU) of resist patterns have become greater than ever. One of the methods for improving CDU of resist pattern is to control the temperature of post-exposure bake (PEB). When ArF resist is used, there is a certain relationship between critical dimension (CD) and PEB temperature. By utilizing this relationship, Resist Pattern CDU can be improved through control of within-wafer temperature distribution in the PEB process. We have already applied this method to Resist Pattern CDU improvement and have achieved these results. In this evaluation, we aim at: 1. Clarifying the relationship between the improvement in Resist Pattern CDU through PEB temperature control and the improvement in Etching Pattern CDU. 2. Verifying whether Resist Pattern CDU improvement through PEB temperature control has any effect on the reduction in wiring resistance variation. The evaluation procedure is: 1. Preparation of wafers with base film of doped Poly-Si (D-Poly). 2. Creation of two sets of samples on the base, a set of samples with good Resist Pattern CDU and a set of samples with poor Resist Pattern CDU. 3. Etching of the two sets under the same conditions. 4. Measurements of CD and wiring resistance. We used Optical CD Measurement (OCD) for measurement of resist pattern and etching pattern for the reason that OCD is minimally affected by Line Edge Roughness (LER). As a result, we found that; 1. The improvement in Resist Pattern CDU leads to the improvement in Etching Pattern CDU . 2. The improvement in Resist Pattern CDU has an effect on the reduction in wiring resistance variation. There is a cause-and-effect relationship between wiring resistance variation and transistor characteristics. From this relationship, we expect that the improvement in Resist Pattern CDU through PEB temperature control can contribute to device performance improvement.
NASA Astrophysics Data System (ADS)
Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho
2013-04-01
As the International Technology Roadmap for Semiconductors critical dimension uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. We will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for advanced extreme ultraviolet (EUV) lithography with 1D (dense lines) and 2D (dense contacts) feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CDs and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples. Mask stack reflectivity variations should also be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We also observed mask error enhancement factor (MEEF) through field fingerprints in the studied EUV cases. Variations of MEEF may play a role towards the total intrafield CDU and may need to be taken into account for EUV lithography. We characterized MEEF-through-field for the reviewed features, with results herein, but further analysis of this phenomenon is required. This comprehensive approach to quantifying the mask part of the overall EUV CDU contribution helps deliver an accurate and integral CDU BB per product/process and litho tool. The better understanding of the entire CDU budget for advanced EUVL nodes achieved by Samsung and ASML helps extend the limits of Moore's Law and to deliver successful implementation of smaller, faster and smarter chips in semiconductor industry.
Go, Michael R; Masterson, Loren; Veerman, Brent; Satiani, Bhagwan
2016-02-01
To curb increasing volumes of diagnostic imaging and costs, reimbursement for carotid duplex ultrasound (CDU) is dependent on "appropriate" indications as documented by International Classification of Diseases (ICD) codes entered by ordering physicians. Historically, asymptomatic indications for CDU yield lower rates of abnormal results than symptomatic indications, and consensus documents agree that most asymptomatic indications for CDU are inappropriate. In our vascular laboratory, we perceived an increased rate of incorrect or inappropriate ICD codes. We therefore sought to determine if ICD codes were useful in predicting the frequency of abnormal CDU. We hypothesized that asymptomatic or nonspecific ICD codes would yield a lower rate of abnormal CDU than symptomatic codes, validating efforts to limit reimbursement in asymptomatic, low-yield groups. We reviewed all outpatient CDU done in 2011 at our institution. ICD codes were recorded, and each medical record was then reviewed by a vascular surgeon to determine if the assigned ICD code appropriately reflected the clinical scenario. CDU findings categorized as abnormal (>50% stenosis) or normal (<50% stenosis) were recorded. Each individual ICD code and group 1 (asymptomatic), group 2 (nonhemispheric symptoms), group 3 (hemispheric symptoms), group 4 (preoperative cardiovascular examination), and group 5 (nonspecific) ICD codes were analyzed for correlation with CDU results. Nine hundred ninety-four patients had 74 primary ICD codes listed as indications for CDU. Of assigned ICD codes, 17.4% were deemed inaccurate. Overall, 14.8% of CDU were abnormal. Of the 13 highest frequency ICD codes, only 433.10, an asymptomatic code, was associated with abnormal CDU. Four symptomatic codes were associated with normal CDU; none of the other high frequency codes were associated with CDU result. Patients in group 1 (asymptomatic) were significantly more likely to have an abnormal CDU compared to each of the other groups (P < 0.001, P < 0.001, P = 0.020, P = 0.002) and to all other groups combined (P < 0.001). Asymptomatic indications by ICD codes yielded higher rates of abnormal CDU than symptomatic indications. This finding is inconsistent with clinical experience and historical data, and we suggest that inaccurate coding may play a role. Limiting reimbursement for CDU in low-yield groups is reasonable. However, reimbursement policies based on ICD coding, for example, limiting payment for asymptomatic ICD codes, may impede use of CDU in high-yield patient groups. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaves, Mario Paul
2017-07-01
For my project I have selected to research and design a high current pulse system, which will be externally triggered from a 5V pulse. The research will be conducted in the region of paralleling the solid state switches for a higher current output, as well as to see if there will be any other advantages in doing so. The end use of the paralleled solid state switches will be used on a Capacitive Discharge Unit (CDU). For the first part of my project, I have set my focus on the design of the circuit, selection of components, and simulation ofmore » the circuit.« less
Automatic speech recognition in air-ground data link
NASA Technical Reports Server (NTRS)
Armstrong, Herbert B.
1989-01-01
In the present air traffic system, information presented to the transport aircraft cockpit crew may originate from a variety of sources and may be presented to the crew in visual or aural form, either through cockpit instrument displays or, most often, through voice communication. Voice radio communications are the most error prone method for air-ground data link. Voice messages can be misstated or misunderstood and radio frequency congestion can delay or obscure important messages. To prevent proliferation, a multiplexed data link display can be designed to present information from multiple data link sources on a shared cockpit display unit (CDU) or multi-function display (MFD) or some future combination of flight management and data link information. An aural data link which incorporates an automatic speech recognition (ASR) system for crew response offers several advantages over visual displays. The possibility of applying ASR to the air-ground data link was investigated. The first step was to review current efforts in ASR applications in the cockpit and in air traffic control and evaluated their possible data line application. Next, a series of preliminary research questions is to be developed for possible future collaboration.
Developing a Performance Data Suite to Facilitate Lean Improvement in a Chemotherapy Day Unit
Lingaratnam, Senthil; Murray, Danielle; Carle, Amber; Kirsa, Sue W.; Paterson, Rebecca; Rischin, Danny
2013-01-01
Purpose: A multidisciplinary team from the Peter MacCallum Cancer Centre in Melbourne, Australia, developed a performance data suite to support a service improvement project based on lean manufacturing principles in its 19-chair chemotherapy day unit (CDU) and cytosuite chemotherapy production facility. The aims of the project were to reduce patient wait time and improve equity of access to the CDU. Methods: A project team consisting of a pharmacist and CDU nurse supported the management team for 10 months in engaging staff and customers to identify waste in processes, analyze root causes, eliminate non–value-adding steps, reduce variation, and level workloads to improve quality and flow. Process mapping, staff and patient tracking and opinion surveys, medical record audits, and interrogation of electronic treatment records were undertaken. Results: This project delivered a 38% reduction in median wait time on the day (from 32 to 20 minutes; P < .01), 7-day reduction in time to commencement of treatment for patients receiving combined chemoradiotherapy regimens (from 25 to 18 days; P < .01), and 22% reduction in wastage associated with expired drug and pharmacy rework (from 29% to 7%; P < .01). Improvements in efficiency enabled the cytosuite to increase the percentage of product manufactured within 10 minutes of appointment times by 29% (from 47% to 76%; P < .01). Conclusion: A lean improvement methodology provided a robust framework for improved understanding and management of complex system constraints within a CDU, resulting in improved access to treatment and reduced waiting times on the day. PMID:23942927
Greenwood, Jennifer; Parsons, Myra
2002-10-01
In Western Sydney, Australia, in 1996, the Area Health Service and the University of Western Sydney entered a strategic alliance to develop a nursing research culture in the health services. One of the strategies implemented to achieve this was the establishment of a network of research-receptive environments known as Clinical Development Units (CDUs). In terms of research receptivity, evidence at the time suggested that it could only be developed in units where the leadership style is democratic and participatory. In terms of CDUs, evidence suggested that their successful development depended critically on the effective management of CDU leadership stressors. In light of this, it was agreed to conduct a CDU leadership preparation program in Western Sydney. The program aimed to furnish CDU leaders with the participatory leadership skills required to develop and manage their units. It was expected that the acquisition of such leadership skills would serve to minimize the leadership stessors they could expect to experience. This is the second of two papers which report course evaluation data. The first focused on the more positive evaluation data; this paper focuses on the negative evaluation data and outlines how the current program has been modified in light of these data. In addition, it discusses two themes which emerged during data analysis. These were nurses' apparent mutual lack of trust and their pressing needs to be recognized as valuable and merit-worthy.
CDU improvement technology of etching pattern using photo lithography
NASA Astrophysics Data System (ADS)
Tadokoro, Masahide; Shinozuka, Shinichi; Jyousaka, Megumi; Ogata, Kunie; Morimoto, Tamotsu; Konishi, Yoshitaka
2008-03-01
Semiconductor manufacturing technology has shifted towards finer design rules, and demands for critical dimension uniformity (CDU) of resist patterns have become greater than ever. One of the methods for improving Resist Pattern CDU is to control post-exposure bake (PEB) temperature. When ArF resist is used, there is a certain relationship between critical dimension (CD) and PEB temperature. By utilizing this relationship, Resist Pattern CDU can be improved through control of within-wafer temperature distribution in the PEB process. Resist Pattern CDU improvement contributes to Etching Pattern CDU improvement to a certain degree. To further improve Etching Pattern CDU, etcher-specific CD variation needs to be controlled. In this evaluation, 1. We verified whether etcher-specific CD variation can be controlled and consequently Etching Pattern CDU can be further improved by controlling resist patterns through PEB control. 2. Verifying whether Etching Pattern CDU improvement through has any effect on the reduction in wiring resistance variation. The evaluation procedure is as follows.1. Wafers with base film of Doped Poly-Si (D-Poly) were prepared. 2. Resist patterns were created on them. 3. To determine etcher-specific characteristics, the first etching was performed, and after cleaning off the resist and BARC, CD of etched D-Poly was measured. 4. Using the obtained within-wafer CD distribution of the etching patterns, within-wafer temperature distribution in the PEB process was modified. 5. Resist patterns were created again, followed by the second etching and cleaning, which was followed by CD measurement. We used Optical CD Measurement (OCD) for measurement of resist patterns and etching patterns as OCD is minimally affected by Line Edge Roughness (LER). As a result, 1. We confirmed the effect of Resist Pattern CD control through PEB control on the reduction in etcher-specific CD variation and the improvement in Etching Pattern CDU. 2. The improvement in Etching Pattern CDU has an effect on the reduction in wiring resistance variation. The method for Etching Pattern CDU improvement through PEB control reduces within-wafer variation of MOS transistor's gate length. Therefore, with this method, we can expect to observe uniform within-wafer MOS transistor characteristics.
Energy Navigation: Simulation Evaluation and Benefit Analysis
NASA Technical Reports Server (NTRS)
Williams, David H.; Oseguera-Lohr, Rosa M.; Lewis, Elliot T.
2011-01-01
This paper presents results from two simulation studies investigating the use of advanced flight-deck-based energy navigation (ENAV) and conventional transport-category vertical navigation (VNAV) for conducting a descent through a busy terminal area, using Continuous Descent Arrival (CDA) procedures. This research was part of the Low Noise Flight Procedures (LNFP) element within the Quiet Aircraft Technology (QAT) Project, and the subsequent Airspace Super Density Operations (ASDO) research focus area of the Airspace Project. A piloted simulation study addressed development of flight guidance, and supporting pilot and Air Traffic Control (ATC) procedures for high density terminal operations. The procedures and charts were designed to be easy to understand, and to make it easy for the crew to make changes via the Flight Management Computer Control-Display Unit (FMC-CDU) to accommodate changes from ATC.
Improving the efficiency of a chemotherapy day unit: applying a business approach to oncology.
van Lent, Wineke A M; Goedbloed, N; van Harten, W H
2009-03-01
To improve the efficiency of a hospital-based chemotherapy day unit (CDU). The CDU was benchmarked with two other CDUs to identify their attainable performance levels for efficiency, and causes for differences. Furthermore, an in-depth analysis using a business approach, called lean thinking, was performed. An integrated set of interventions was implemented, among them a new planning system. The results were evaluated using pre- and post-measurements. We observed 24% growth of treatments and bed utilisation, a 12% increase of staff member productivity and an 81% reduction of overtime. The used method improved process design and led to increased efficiency and a more timely delivery of care. Thus, the business approaches, which were adapted for healthcare, were successfully applied. The method may serve as an example for other oncology settings with problems concerning waiting times, patient flow or lack of beds.
An evaluation of flight path management automation in transport category aircraft
NASA Technical Reports Server (NTRS)
Chandra, D.; Bussolari, S. R.
1991-01-01
A desk-top simulation of a Boeing 757/767 Electronic Flight Instrumentation System (EFIS) and Control Display Unit (CDU) was used in an experiment to compare three modes of communication for the clearance amendment process: standard voice procedures, a textual delivery method, and a graphical delivery method. Eight qualified Boeing 757/767 pilots served as subjects. Each flew nine landing scenarios with three amendments given in each scenario. Both acceptable and unacceptable clearance amendments were presented in order to assess situational awareness. Times for comprehension and execution of the amendment were recorded along with workload ratings, responses to unacceptable amendments, and subjective impressions. The graphical mode was found to be superior in terms of the time measures and subjective ratings. No difference was found between the modes in the ability to detect unacceptable clearances.
Crew Procedures for Continuous Descent Arrivals Using Conventional Guidance
NASA Technical Reports Server (NTRS)
Oseguera-Lohr, Rosa M.; Williams, David H.; Lewis, Elliot T,
2007-01-01
This paper presents results from a simulation study which investigated the use of Continuous Descent Arrival (CDA) procedures for conducting a descent through a busy terminal area, using conventional transport-category automation. This research was part of the Low Noise Flight Procedures (LNFP) element within the Quiet Aircraft Technology (QAT) Project, that addressed development of flight guidance, and supporting pilot and Air Traffic Control (ATC) procedures for low noise operations. The procedures and chart were designed to be easy to understand, and to make it easy for the crew to make changes via the Flight Management Computer Control-Display Unit (FMC-CDU) to accommodate changes from ATC. The test runs were intended to represent situations typical of what exists in many of today's terminal areas, including interruptions to the descent in the form of clearances issued by ATC.
Wang, H-K; Chen, C-Y; Lin, N-C; Liu, C-S; Loong, C-C; Lin, Y-H; Lai, Y-C; Chiou, H-J
2018-05-01
Intraoperative portal venous flow measurement provides surgeons with instant guidance for portal flow modulation during living-donor liver transplantation (LDLT). In this study, we compared the agreement of portal flow measurement obtained by 2 devices: transit time ultrasound (TTU) and conventional Doppler ultrasound (CDU). Fifty-four recipients of LDLT underwent intraoperative measurement of portal flow after completion of vascular anastomosis of the implanted partial liver graft. Both TTU and CDU were used concurrently. Agreement of TTU and CDU was assessed by intraclass correlation coefficient using a model of 2-way random effects, absolute agreement, and single measurement. A Bland-Altman plot was applied to assess the variability between the 2 devices. The mean, median, and range of portal venous flow was 1456, 1418, and 117 to 2776 mL/min according to TTU; and 1564, 1566, and 119 to 3216 mL/min according to CDU. The intraclass correlation coefficient of portal venous flow between TTU and CDU was 0.68 (95% confidence interval, 0.51-0.80). The Bland-Altman plots revealed an average variation of 4.8% between TTU and CDU but with a rather wide 95% confidence interval of variation ranging from -57.7% to 67.4%. Intraoperative TTU and CDU showed moderate agreement in portal flow measurement. However, a relatively wide range of variation exists between TTU and CDU, indicating that data obtained from the 2 devices may not be interchangeable. Copyright © 2018 Elsevier Inc. All rights reserved.
DDR process and materials for novel tone reverse technique
NASA Astrophysics Data System (ADS)
Shigaki, Shuhei; Shibayama, Wataru; Takeda, Satoshi; Tamura, Mamoru; Nakajima, Makoto; Sakamoto, Rikimaru
2018-03-01
We developed the novel process and material which can be created reverse-tone pattern without any collapse. The process was Dry Development Rinse (DDR) process, and the material used in this process was DDR material. DDR material was containing siloxane polymer which could be replaced the space area of the photo resist pattern. And finally, the reverse-tone pattern could be obtained by dry etching process without any pattern collapse issue. DDR process could be achieved fine line and space patterning below hp14nm without any pattern collapse by combination of PTD or NTD photo resist. DDR materials were demonstrated with latest coater track at imec. DDR process was fully automated and good CD uniformity was achieved after dry development. Detailed evaluation could be achieved with whole wafer such a study of CD uniformity (CDU). CDU of DDR pattern was compared to pre-pattern's CDU. Lower CDU was achieved and CDU healing was observed with special DDR material. By further evaluation, special DDR material showed relatively small E-slope compared to another DDR material. This small E-slope caused CDU improvement.
Chung, Eric; Yan, Hanmu; De Young, Ling; Brock, Gerald B
2012-10-01
What's known on the subject? and What does the study add? Penile colour Doppler ultrasonography (CDU) can be an invaluable investigative tool to characterize penile abnormalities to complement clinical history and physical examination in the evaluation of men with Peyronie's disease (PD) and/or erectile dysfunction (ED). Although CDU findings between men with PD and those with ED were not markedly different, subtle differences were observed. The classic penile CDU findings in men with PD comprise tunical thickening, intracavernosal fibrosis, septal fibrosis and intracavernosal calcification, while, in men with ED, low peak systolic velocity and high end-diastolic velocity are found on penile haemodynamics. Previously published studies have focused predominantly on either ED or PD exclusively, or examine the risk of progression to ED in the PD population. To our knowledge, this is the largest and most comprehensive analysis of penile CDU and clinical findings in men with PD and/or ED. The large sample size and multivariable analysis allow meaningful interpretation of the results. This study has found some substantial differences in the penile CDU findings of men with PD and/or ED that have not previously been reported. Although the risk factors of ED may be greater than those for PD, there is crossover in age, cardiovascular risk factors, trauma and penile CDU findings in men with PD and/or ED. To explore the differences in penile colour Doppler ultrasonography (CDU) findings between men with Peyronie's disease (PD) and those with erectile dysfunction (ED). Patients presenting with PD and/or ED who underwent penile CDU were recruited to the study. Patient demographics, comorbidities, International Index of Erectile Function-5 scores, previous therapies and physical findings were documented. Penile curvature, presence of tunical thickening, septal fibrosis, intracavernosal fibrosis and calcification, and cavernosal vascular status were recorded. A total of 1500 men underwent penile CDU during the 10-year period. Of these men, 891 men presented with PD and 609 men had ED only. Men with ED had higher rates of diabetes and coronary artery disease (P < 0.05). Isolated tunical thickening was more common in older men and in the PD cohort. The presence of intracavernosal fibrosis correlated strongly with difficulty maintaining erection (P < 0.05). Impaired cavernosal arterial flow was observed in men with decrease penile rigidity and penile pain, while higher end-diastolic velocities were found in men with difficulty maintaining erection and tunical thickening on penile CDU. Men with PD and ED had many similarities and differences on penile CDU. Penile CDU continues to be an invaluable clinical tool in the management of men with male sexual dysfunction. © 2012 BJU INTERNATIONAL.
Post exposure bake unit equipped with wafer-shape compensation technology
NASA Astrophysics Data System (ADS)
Goto, Shigehiro; Morita, Akihiko; Oyama, Kenichi; Hori, Shimpei; Matsuchika, Keiji; Taniguchi, Hideyuki
2007-03-01
In 193nm lithography, it is well known that Critical Dimension Uniformity (CDU) within wafer is especially influenced by temperature variation during Post Exposure Bake (PEB) process. This temperature variation has been considered to be caused by the hot plate unit, and improvement of temperature uniformity within hot plate itself has been focused to achieve higher CDU. However, we have found that the impact of the wafer shape on temperature uniformity within wafer can not be ignored when the conventional PEB processing system is applied to an advanced resist technology. There are two factors concerned with the wafer shape. First, gravity force of the wafer itself generates wafer shape bending because wafer is simply supported by a few proximity gaps on the conventional hot plate. Next, through the semiconductor manufacturing process, wafer is gradually warped due to the difference of the surface stress between silicon and deposited film layers (Ex. Si-Oxide, Si-Nitride). Therefore, the variation of the clearance between wafer backside and hot plate surface leads to non-uniform thermal conductivity within wafer during PEB processing, and eventually impacts on the CDU within wafer. To overcome this problem concerned with wafer shape during PEB processing, we have developed the new hot plate equipped with the wafer shape compensation technology. As a result of evaluation, we have confirmed that this new PEB system has an advantage not only for warped wafer but also for flat (bare) wafer.
Gwala, Poonam; Andey, Subhash; Nagarnaik, Pranav; Ghosh, Sarika Pimpalkar; Pal, Prashant; Deshmukh, Prashant; Labhasetwar, Pawan
2014-08-01
Decentralised household chemo defluoridation unit (CDU) was developed and designed based on a combination of coagulation and sorption processes. Chemo-defluoridation process was optimised to reduce use of chemicals and increase acceptability among beneficiaries without affecting palatability of water. Chemical dose optimization undertaken in the laboratory using jar test revealed the optimum calcium salt to initial fluoride ratio of 60 for fluoride removal. Performance of CDU was evaluated in the laboratory for removal efficiency, water quality parameters, filter bed cleaning cycle and desorption of fluoride. CDU evaluation in the laboratory with spiked water (5 mg/L) and field water (~4.2 mg/L) revealed treated water fluoride concentration of less than 1mg/L. Seventy five CDUs were installed in households at Sakhara Village, Yavatmal District in Maharashtra State of India. Monthly monitoring of CDUs for one year indicated reduction of the raw water fluoride concentration from around 4 mg/L to less than 1mg/L. Post implementation survey after regular consumption of treated drinking water by the users for one year indicated user satisfaction and technological sustainability. Copyright © 2014 Elsevier B.V. All rights reserved.
Within-wafer CD variation induced by wafer shape
NASA Astrophysics Data System (ADS)
Huang, Chi-hao; Yang, Mars; Yang, Elvis; Yang, T. H.; Chen, K. C.
2016-03-01
In order to meet the increasing storage capacity demand and reduce bit cost of NAND flash memories, 3D stacked vertical flash cell array has been proposed. In constructing 3D NAND flash memories, the bit number per unit area is increased as increasing the number of stacked layers. However, the increased number of stacked layers has made the film stress control extremely important for maintaining good process quality. The residual film stress alters the wafer shape accordingly several process impacts have been readily observed across wafer, such as film deposition non-uniformity, etch rate non-uniformity, wafer chucking error on scanner, materials coating/baking defects, overlay degradation and critical dimension (CD) non-uniformity. The residual tensile and compressive stresses on wafers will result in concave and convex wafer shapes, respectively. This study investigates within-wafer CD uniformity (CDU) associated with wafer shape change induced by the 3D NAND flash memory processes. Within-wafer CDU was correlated with several critical parameters including different wafer bow heights of concave and convex wafer shapes, photo resists with different post exposure baking (PEB) temperature sensitivities, and DoseMapper compensation. The results indicated the trend of within-wafer CDU maintains flat for convex wafer shapes with bow height up to +230um and concave wafer shapes with bow height ranging from 0 ~ -70um, while the within-wafer CDU trends up from -70um to -246um wafer bow heights. To minimize the within-wafer CD distribution induced by wafer warpage, carefully tailoring the film stack and thermal budget in the process flow for maintaining the wafer shape at CDU friendly range is indispensable and using photo-resist materials with lower PEB temperature sensitivity is also suggested. In addition, DoseMapper compensation is also an alternative to greatly suppress the within-wafer CD non-uniformity but the photo-resist profile variation induced by across-wafer PEB temperature non-uniformity attributed to wafer warpage is uncorrectable, and the photo-resist profile variation is believed to affect across-wafer etch bias uniformity to some degree.
Magadzire, Bvudzai Priscilla; Marchal, Bruno; Mathys, Tania; Laing, Richard O; Ward, Kim
2017-12-04
Centralized dispensing of essential medicines is one of South Africa's strategies to address the shortage of pharmacists, reduce patients' waiting times and reduce over-crowding at public sector healthcare facilities. This article reports findings of an evaluation of the Chronic Dispensing Unit (CDU) in one province. The objectives of this process evaluation were to: (1) compare what was planned versus the actual implementation and (2) establish the causal elements and contextual factors influencing implementation. This qualitative study employed key informant interviews with the intervention's implementers (clinicians, managers and the service provider) [N = 40], and a review of policy and program documents. Data were thematically analyzed by identifying the main influences shaping the implementation process. Theory-driven evaluation principles were applied as a theoretical framework to explain implementation dynamics. The overall participants' response about the CDU was positive and the majority of informants concurred that the establishment of the CDU to dispense large volumes of medicines is a beneficial strategy to address healthcare barriers because mechanical functions are automated and distribution of medicines much quicker. However, implementation was influenced by the context and discrepancies between planned activities and actual implementation were noted. Procurement inefficiencies at central level caused medicine stock-outs and affected CDU activities. At the frontline, actors were aware of the CDU's implementation guidelines regarding patient selection, prescription validity and management of non-collected medicines but these were adapted to accommodate practical realities and to meet performance targets attached to the intervention. Implementation success was a result of a combination of 'hardware' (e.g. training, policies, implementation support and appropriate infrastructure) and 'software' (e.g. ownership, cooperation between healthcare practitioners and trust) factors. This study shows that health system interventions have unpredictable paths of implementation. Discrepancies between planned and actual implementation reinforce findings in existing literature suggesting that while tools and defined operating procedures are necessary for any intervention, their successful application depends crucially on the context and environment in which implementation occurs. We anticipate that this evaluation will stimulate wider thinking about the implementation of similar models in low- and middle-income countries.
Inline detection of Chrome degradation on binary 193nm photomasks
NASA Astrophysics Data System (ADS)
Dufaye, Félix; Sippel, Astrid; Wylie, Mark; García-Berríos, Edgardo; Crawford, Charles; Hess, Carl; Sartelli, Luca; Pogliani, Carlo; Miyashita, Hiroyuki; Gough, Stuart; Sundermann, Frank; Brochard, Christophe
2013-09-01
193nm binary photomasks are still used in the semiconductor industry for the lithography of some critical layers for the nodes 90nm and 65nm, with high volumes and over long periods. However, these 193nm binary photomasks can be impacted by a phenomenon of chrome oxidation leading to critical dimensions uniformity (CDU) degradation with a pronounced radial signature. If not detected early enough, this CDU degradation may cause defectivity issues and lower yield on wafers. Fortunately, a standard cleaning and repellicle service at the mask shop has been demonstrated as efficient to remove the grown materials and get the photomask CD back on target.Some detection methods have been already described in literature, such as wafer CD intrafield monitoring (ACLV), giving reliable results but also consuming additional SEM time with less precision than direct photomask measurement. In this paper, we propose another approach, by monitoring the CDU directly on the photomask, concurrently with defect inspection for regular requalification to production for wafer fabs. For this study, we focused on a Metal layer in a 90nm technology node. Wafers have been exposed with production conditions and then measured by SEM-CD. Afterwards, this photomask has been measured with a SEM-CD in mask shop and also inspected on a KLA-Tencor X5.2 inspection system, with pixels 125 and 90nm, to evaluate the Intensity based Critical Dimension Uniformity (iCDU) option. iCDU was firstly developed to provide feed-forward CDU maps for scanner intrafield corrections, from arrayed dense structures on memory photomasks. Due to layout complexity and differing feature types, CDU monitoring on logic photomasks used to pose unique challenges.The selection of suitable feature types for CDU monitoring on logic photomasks is no longer an issue, since the transmitted intensity map gives all the needed information, as shown in this paper. In this study, the photomask was heavily degraded after more than 18,000 300mm wafers exposed and the cleaning brought it back almost to its original state after manufacture. Wafer CD, photomask CD and iCDU results can be compared, before and after a standard mask shop cleaning. Measurement points have be chosen in logic areas and SRAM areas, so that their respective behaviours can be studied separately. Transmitted maps before and after cleaning were analysed in terms of CD shift and CDU degradation. The delta map shows a nice correlation with photomask CD shift. iCDU demonstrated the capability to detect a reliable CD range degradation of 5nm on photomask by a comparison between a reference inspection and the current inspection. Die to die inspection mode provides also valuable data, highlighting the degraded chrome sidewalls, more in the photomask centre than on the edges. Ultimately, these results would enable to trigger the preventive cleanings rather than on predefined thresholds. The expected gains for wafer fabs are cost savings (adapted cleanings frequency), increased photomask availability for production, longer photomask lifetime, no additional SEM time neither for photomask nor on wafer.
A piloted simulation study of data link ATC message exchange
NASA Technical Reports Server (NTRS)
Waller, Marvin C.; Lohr, Gary W.
1989-01-01
Data link Air Traffic Control (ATC) and Air Traffic Service (ATS) message and data exchange offers the potential benefits of increased flight safety and efficiency by reducing communication errors and allowing more information to be transferred between aircraft and ground facilities. Digital communication also presents an opportunity to relieve the overloading of ATC radio frequencies which hampers message exchange during peak traffic hours in many busy terminal areas. A piloted simulation study to develop pilot factor guidelines and assess potential flight crew benefits and liabilities from using data link ATC message exchange was completed. The data link ATC message exchange concept, implemented on an existing navigation computer Control Display Unit (CDU) required maintaining a voice radio telephone link with an appropriate ATC facility. Flight crew comments, scanning behavior, and measurements of time spent in ATC communication activities for data link ATC message exchange were compared to similar measures for simulated conventional voice radio operations. The results show crew preference for the quieter flight deck environment and a perception of lower communication workload.
High-Performance Computing Data Center Cooling System Energy Efficiency |
approaches involve a cooling distribution unit (CDU) (2), which interfaces with the facility cooling loop and to the energy recovery water (ERW) loop (5), which is a closed-loop system. There are three heat rejection options for this IT load: When possible, heat energy from the energy recovery loop is transferred
Kim, Se Hyung; Lee, Jeong Min; Kim, Young Jun; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn
2008-10-01
The purpose of this study was to introduce a new high-definition flow (HDF) Doppler technique and to compare its performance with those of color Doppler ultrasonography (CDU) and power Doppler ultrasonography (PDU) for assessment of hepatic vasculature in native and transplanted livers. High-definition flow was invented as a high-resolution bidirectional PDU technique. We obtained CDU, PDU, and HDF images of the hepatic artery (HA), portal vein (PV), and hepatic vein from 60 patients. They were divided into 2 groups: a liver transplantation group (group 1, n = 10) and a native liver group (group 2, n = 50). Two radiologists independently reviewed the cine images and graded them using a 4-point scale in terms of the clarity of the vessel margin and degree of depiction of the HA, flow filling, and flash artifacts. The degree of differentiation between the HA and PV was also evaluated. Flow directionality was recorded, and interobserver agreement was finally analyzed. Moderate to almost perfect agreement was achieved between radiologists for all parameters of each ultrasonographic technique. High-definition flow was significantly superior to both CDU and PDU with respect to all analyzed items except the degree of flash artifacts (P < .05). With regard to flash artifacts, CDU was significantly better than either PDU or HDF. High-definition flow provided directional information, as did CDU. The HDF technique provides better resolution for depicting hepatic vessels as well as their margins with less blooming compared with conventional Doppler ultrasonography in both native and transplanted liver. It also provides solid directional flow information. One point of concern, however, is the frequency of flash artifacts compared with that on CDU.
Improved mask-based CD uniformity for gridded-design-rule lithography
NASA Astrophysics Data System (ADS)
Faivishevsky, Lev; Khristo, Sergey; Sagiv, Amir; Mangan, Shmoolik
2009-03-01
The difficulties encountered during lithography of state-of-the-art 2D patterns are formidable, and originate from the fact that deep sub-wavelength features are being printed. This results in a practical limit of k1 >=0.4 as well as a multitude of complex restrictive design rules, in order to mitigate or minimize lithographic hot spots. An alternative approach, that is gradually attracting the lithographic community's attention, restricts the design of critical layers to straight, dense lines (a 1D grid), that can be relatively easily printed using current lithographic technology. This is then followed by subsequent, less critical trimming stages to obtain circuit functionality. Thus, the 1D gridded approach allows hotspot-free, proximity-effect free lithography of ultra low- k1 features. These advantages must be supported by a stable CD control mechanism. One of the overriding parameters impacting CDU performance is photo mask quality. Previous publications have demonstrated that IntenCDTM - a novel, mask-based CDU mapping technology running on Applied Materials' Aera2TM aerial imaging mask inspection tool - is ideally fit for detecting mask-based CDU issues in 1D (L&S) patterned masks for memory production. Owing to the aerial nature of image formation, IntenCD directly probes the CD as it is printed on the wafer. In this paper we suggest that IntenCD is naturally fit for detecting mask-based CDU issues in 1D GDR masks. We then study a novel method of recovering and quantifying the physical source of printed CDU, using a novel implementation of the IntenCD technology. We demonstrate that additional, simple measurements, which can be readily performed on board the Aera2TM platform with minimal throughput penalty, may complement IntenCD and allow a robust estimation of the specific nature and strength of mask error source, such as pattern width variation or phase variation, which leads to CDU issues on the printed wafer. We finally discuss the roles played by IntenCD in advanced GDR mask production, starting with tight control over mask production process, continuing to mask qualification at mask shop and ending at in-line wafer CDU correction in fabs.
Expanding Library Services and Instruction Through LibGuides.
Ream, Tim; Parker-Kelly, Darlene
2016-01-01
Beginning in 2012, the Charles R. Drew University (CDU) Health Sciences Library used LibGuides in a number of innovative ways. Librarians constructed e-book databases, in-depth tutorials on technology-related topics, and web pages highlighting special events. To assess similar LibGuides innovation, CDU librarians developed an eight-question survey distributed to health sciences and hospital libraries throughout Southern California and Arizona. Results showed that libraries used LibGuides primarily to deliver access to online resources and to provide supplementary materials supporting instruction. Responses also revealed that many libraries had not yet adopted LibGuides. These findings were analyzed and compared to past and current LibGuides design at CDU.
Optically triggered fire set/detonator system
Chase, Jay B.; Pincosy, Philip A.; Chato, Donna M.; Kirbie, Hugh; James, Glen F.
2007-03-20
The present invention is directed to a system having a plurality of capacitor discharge units (CDUs) that includes electrical bridge type detonators operatively coupled to respective explosives. A pulse charging circuit is adapted to provide a voltage for each respective capacitor in each CDU. Such capacitors are discharged through the electrical bridge type detonators upon receiving an optical signal to detonate respective operatively coupled explosives at substantially the same time.
NASA Astrophysics Data System (ADS)
Thamm, Thomas; Geh, Bernd; Djordjevic Kaufmann, Marija; Seltmann, Rolf; Bitensky, Alla; Sczyrba, Martin; Samy, Aravind Narayana
2018-03-01
Within the current paper, we will concentrate on the well-known CDC technique from Carl Zeiss to improve the CD distribution of the wafer by improving the reticle CDU and its impact on hotspots and Litho process window. The CDC technique uses an ultra-short pulse laser technology, which generates a micro-level Shade-In-Element (also known as "Pixels") into the mask quartz bulk material. These scatter centers are able to selectively attenuate certain areas of the reticle in higher resolution compared to other methods and thus improve the CD uniformity. In a first section, we compare the CDC technique with scanner dose correction schemes. It becomes obvious, that the CDC technique has unique advantages with respect to spatial resolution and intra-field flexibility over scanner correction schemes, however, due to the scanner flexibility across wafer both methods are rather complementary than competing. In a second section we show that a reference feature based correction scheme can be used to improve the CDU of a full chip with multiple different features that have different MEEF and dose sensitivities. In detail we will discuss the impact of forward scattering light originated by the CDC pixels on the illumination source and the related proximity signature. We will show that the impact on proximity is small compared to the CDU benefit of the CDC technique. Finally we show to which extend the reduced variability across reticle will result in a better common electrical process window of a whole chip design on the whole reticle field on wafer. Finally we will discuss electrical verification results between masks with purposely made bad CDU that got repaired by the CDC technique versus inherently good "golden" masks on a complex logic device. No yield difference is observed between the repaired bad masks and the masks with good CDU.
1988-02-23
Loss of Ground 11 Excessive Trust, Excessive Disillusionment [Jose Miguel Judice; SEMANARIO, 19 Dec 87] .. 11 Lack of Opposition Seen as...the CDU associations Westphalia and Rhineland is to make any sense, then one must combine forces. And naturally this weight influences the formation...SPD to its desired objective. CDU/CSU losses in past months have been offset by FDP gains , and the opposition has not become stronger overall—there
Lotti, F; Corona, G; Mondaini, N; Maseroli, E; Rossi, M; Filimberti, E; Noci, I; Forti, G; Maggi, M
2014-01-01
'Prostatitis-like symptoms' (PLS) are a cluster of bothersome conditions defined as 'perineal and/or ejaculatory pain or discomfort and National Institutes of Health-Chronic Prostatitis Symptom Index (NIH-CPSI) pain subdomain score ≥4' (Nickel's criteria). PLS may originate from the prostate or from other portions of the male genital tract. Although PLS could be associated with 'prostatitis', they should not be confused. The NIH-CPSI is considered the gold-standard for assessing PLS severity. Although previous studies investigated the impact of prostatitis, vesiculitis or epididymitis on semen parameters, correlations between their related symptoms and seminal or scrotal/transrectal colour-Doppler ultrasound (CDU) characteristics have not been carefully determined. And no previous study evaluated the CDU features of PLS in infertile men. This study was aimed at investigating possible associations among NIH-CPSI (total and subdomain) scores and PLS, with seminal, clinical and scrotal/transrectal CDU parameters in a cohort of males of infertile couples. PLS of 400 men (35.8 ± 7.2 years) with a suspected male factor were assessed by the NIH-CPSI. All patients underwent, during the same day, semen analysis, seminal plasma interleukin 8 (sIL-8, a marker of male genital tract inflammation), biochemical evaluation, urine/seminal cultures, scrotal/transrectal CDU. PLS was detected in 39 (9.8%) subjects. After adjusting for age, waist and total testosterone (TT), no association among NIH-CPSI (total or subdomain) scores or PLS and sperm parameters was observed. However, we found a positive association with current positive urine and/or seminal cultures, sIL-8 levels and CDU features suggestive of inflammation of the epididymis, seminal vesicles, prostate, but not of the testis. The aforementioned significant associations of PLS were further confirmed by comparing PLS patients with age-, waist- and TT-matched PLS-free patients (1 : 3 ratio). In conclusion, NIH-CPSI scores and PLS evaluated in males of infertile couples, are not related to sperm parameters, but mainly to clinical and CDU signs of infection/inflammation. © 2013 American Society of Andrology and European Academy of Andrology.
Translations on Eastern Europe Political, Sociological, and Military Affairs No. 1575
1978-08-08
Developments in European Communist Movement Assessed (Alfred Marter; HORIZONT, No 27, 1978) 49 Position of Churches, CDU on Military Training Stated...Editorial; FRANKFURTER RUNDSCHAU, 29 Jun 78) 58 Protestant League Guidelines CDU Position Paper West German Comment: GDR Church Hits School...conspicuously aggravated external economic conditions, the balance of the party’s economic policy is positive . Thus, the recent years are honorably linked with
NASA Astrophysics Data System (ADS)
Tiffany, Jason E.; Cohen, Barney M.
2004-05-01
As line widths approach 90nm node in volume production, post exposure bake (PEB) uniformity becomes a much larger component of the across wafer critical dimension uniformity (CDU). In production, the need for PEB plate matching has led to novel solutions such as plate specific dose offsets. This type of correction does not help across wafer CDU. Due to unequal activation energies of the critical PEB processes, any thermal history difference can result in a corresponding CD variation. The rise time of the resist to the target temperature has been shown to affect CD, with the most critical time being the first 5-7 seconds. A typical PEB plate has multi-zone thermal control with one thermal sensor per zone. The current practice is to setup each plate to match the steady-state target temperature, ignoring any dynamic performance. Using an in-situ wireless RTD wafer, it is possible to characterize the dynamic performance, or time constant, of each RTD location on the sensing wafer. Constrained by the zone structure of the PEB plate, the proportional, integral and derivative (PID) settings of each controller channel could be optimized to reduce the variations in rise time across the RTD wafer, thereby reducing the PEB component of across wafer CDU.
Airborne Data Link Operational Evaluation Test Plan
1993-08-01
be provided by a combination of glare shield mounted, blue lens , aviation-type lamps and lighted distinctive message indicators on the CDUs or CDU...consist of either SELCAL sound only or SELCAL tone combined with forward primary field of view visual alerting (a blue light mounted on the glare shield in...INCORPORATED DOT/FAA/CT-TN93/30 9. Pe’form,"g Orgaoniatio Name end Address 10. Work Unit No. (TRAIS) CTA, INCORPORATED Suite 1000 11 Contac of Great me. 2500
EUV process establishment through litho and etch for N7 node
NASA Astrophysics Data System (ADS)
Kuwahara, Yuhei; Kawakami, Shinichiro; Kubota, Minoru; Matsunaga, Koichi; Nafus, Kathleen; Foubert, Philippe; Mao, Ming
2016-03-01
Extreme ultraviolet lithography (EUVL) technology is steadily reaching high volume manufacturing for 16nm half pitch node and beyond. However, some challenges, for example scanner availability and resist performance (resolution, CD uniformity (CDU), LWR, etch behavior and so on) are remaining. Advance EUV patterning on the ASML NXE:3300/ CLEAN TRACK LITHIUS Pro Z- EUV litho cluster is launched at imec, allowing for finer pitch patterns for L/S and CH. Tokyo Electron Ltd. and imec are continuously collabo rating to develop manufacturing quality POR processes for NXE:3300. TEL's technologies to enhance CDU, defectivity and LWR/LER can improve patterning performance. The patterning is characterized and optimized in both litho and etch for a more complete understanding of the final patterning performance. This paper reports on post-litho CDU improvement by litho process optimization and also post-etch LWR reduction by litho and etch process optimization.
The future of 2D metrology for display manufacturing
NASA Astrophysics Data System (ADS)
Sandstrom, Tor; Wahlsten, Mikael; Park, Youngjin
2016-10-01
The race to 800 PPI and higher in mobile devices and the transition to OLED displays are driving a dramatic development of mask quality: resolution, CDU, registration, and complexity. 2D metrology for large area masks is necessary and must follow the roadmap. Driving forces in the market place point to continued development of even more dense displays. State-of-the-art metrology has proven itself capable of overlay below 40 nm and registration below 65 nm for G6 masks. Future developments include incoming and recurrent measurements of pellicalized masks at the panel maker's factory site. Standardization of coordinate systems across supplier networks is feasible. This will enable better yield and production economy for both mask and panel maker. Better distortion correction methods will give better registration on the panels and relax the flatness requirements of the mask blanks. If panels are measured together with masks and the results are used to characterize the aligners, further quality and yield improvements are possible. Possible future developments include in-cell metrology and integration with other instruments in the same platform.
Alternative stitching method for massively parallel e-beam lithography
NASA Astrophysics Data System (ADS)
Brandt, Pieter; Tranquillin, Céline; Wieland, Marco; Bayle, Sébastien; Milléquant, Matthieu; Renault, Guillaume
2015-03-01
In this study a novel stitching method other than Soft Edge (SE) and Smart Boundary (SB) is introduced and benchmarked against SE. The method is based on locally enhanced Exposure Latitude without cost of throughput, making use of the fact that the two beams that pass through the stitching region can deposit up to 2x the nominal dose. The method requires a complex Proximity Effect Correction that takes a preset stitching dose profile into account. On a Metal clip at minimum half-pitch of 32 nm for MAPPER FLX 1200 tool specifications, the novel stitching method effectively mitigates Beam to Beam (B2B) position errors such that they do not induce increase in CD Uniformity (CDU). In other words, the same CDU can be realized inside the stitching region as outside the stitching region. For the SE method, the CDU inside is 0.3 nm higher than outside the stitching region. 5 nm direct overlay impact from B2B position errors cannot be reduced by a stitching strategy.
Digital Baseband Architecture For Transponder
NASA Technical Reports Server (NTRS)
Nguyen, Tien M.; Yeh, Hen-Geul
1995-01-01
Proposed advanced transponder for long-distance radio communication system with turnaround ranging contains carrier-signal-tracking loop including baseband digital "front end." For reduced cost, transponder includes analog intermediate-frequency (IF) section and analog automatic gain control (AGC) loop at first of two IF mixers. However, second IF mixer redesigned to ease digitization of baseband functions. To conserve power and provide for simpler and smaller transponder hardware, baseband digital signal-processing circuits designed to implement undersampling scheme. Furthermore, sampling scheme and sampling frequency chosen so redesign involves minimum modification of command-detector unit (CDU).
Co-exposure to lead increases the renal response to low levels of cadmium in metallurgy workers.
Hambach, R; Lison, D; D'Haese, P C; Weyler, J; De Graef, E; De Schryver, A; Lamberts, L V; van Sprundel, M
2013-10-24
Research on the effect of co-exposure to Cd and Pb on the kidney is scarce. The objective of the present study was to assess the effect of co-exposure to these metals on biomarkers of early renal effect. Cd in blood (Cd-B), Cd in urine (Cd-U), Pb in blood (Pb-B) and urinary renal biomarkers, i.e., microalbumin (μ-Alb), beta-2-microglobulin (β₂-MG), retinol binding protein (RBP), N-acetyl-β-d-glucosaminidase (NAG), intestinal alkaline phosphatase (IAP) were measured in 122 metallurgic refinery workers examined in a cross-sectional survey. The median Cd-B, Cd-U, Pb-B were: 0.8 μg/l (IQR = 0.5, 1.2), 0.5 μg/g creatinine (IQR = 0.3, 0.8) and 158.5 μg/l (IQR = 111.0, 219.3), respectively. The impact of Cd-B on the urinary excretion of NAG and IAP was only evident among workers with Pb-B concentrations ≥ 75th percentile. The association between Cd-U and the renal markers NAG and RBP was also evidenced when Pb-B ≥ 75th percentile. No statistically significant interaction terms were observed for the associations between Cd-B or Cd-U and the other renal markers under study (i.e., μ-Alb and β2-MG). Our findings indicate that Pb increases the impact of Cd exposure on early renal biomarkers. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Critical dimension control using ultrashort laser for improving wafer critical dimension uniformity
NASA Astrophysics Data System (ADS)
Avizemer, Dan; Sharoni, Ofir; Oshemkov, Sergey; Cohen, Avi; Dayan, Asaf; Khurana, Ranjan; Kewley, Dave
2015-07-01
Requirements for control of critical dimension (CD) become more demanding as the integrated circuit (IC) feature size specifications become tighter and tighter. Critical dimension control, also known as CDC, is a well-known laser-based process in the IC industry that has proven to be robust, repeatable, and efficient in adjusting wafer CD uniformity (CDU) [Proc. SPIE
Safe disposal of cytotoxic waste: an evaluation of an air-tight system.
Craig, Gemma; Wadey, Charlotte
2017-09-07
A 3-month evaluation was undertaken at the Kent Oncology Centre's chemotherapy day unit (CDU) to trial an air-tight sealing disposal system for cytotoxic waste management. Research has identified the potential risk to staff who handle waste products that are hazardous to health. Staff safety was a driving force behind a trial of a new way of working. This article provides an overview of the evaluation of the Pactosafe system in one clinical area, examining reviews by oncology healthcare workers, the practicalities in the clinical setting, training, cost effectiveness and the environmental benefits.
Semiconductor bridge, SCB, ignition studies of Al/CuO thermite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickes, R.W. Jr.; Wackerbarth, D.E.; Mohler, J.H.
1997-04-01
The authors briefly summarize semiconductor bridge operation and review their ignition studies of Al/CuO thermite as a function of the capacitor discharge unit (CDU) firing set capacitance, charge holder material and morphology of the CuO. Ignition thresholds were obtained using a brass charge holder and a non-conducting fiber-glass-epoxy composite material, G10. At - 18 C and a charge voltage of 50V, the capacitance thresholds were 30.1 {mu}F and 2.0 {mu}F respectively. They also present new data on electrostatic discharge (ESD) and radio frequency (RF) vulnerability tests.
Alternative stitching method for massively parallel e-beam lithography
NASA Astrophysics Data System (ADS)
Brandt, Pieter; Tranquillin, Céline; Wieland, Marco; Bayle, Sébastien; Milléquant, Matthieu; Renault, Guillaume
2015-07-01
In this study, a stitching method other than soft edge (SE) and smart boundary (SB) is introduced and benchmarked against SE. The method is based on locally enhanced exposure latitude without throughput cost, making use of the fact that the two beams that pass through the stitching region can deposit up to 2× the nominal dose. The method requires a complex proximity effect correction that takes a preset stitching dose profile into account. Although the principle of the presented stitching method can be multibeam (lithography) systems in general, in this study, the MAPPER FLX 1200 tool is specifically considered. For the latter tool at a metal clip at minimum half-pitch of 32 nm, the stitching method effectively mitigates beam-to-beam (B2B) position errors such that they do not induce an increase in critical dimension uniformity (CDU). In other words, the same CDU can be realized inside the stitching region as outside the stitching region. For the SE method, the CDU inside is 0.3 nm higher than outside the stitching region. A 5-nm direct overlay impact from the B2B position errors cannot be reduced by a stitching strategy.
Magadzire, Bvudzai P; Ward, Kim; Leng, Henry M J; Sanders, David
2017-06-30
South Africa (SA) has experienced several stock-outs of life-saving medicines for the treatment of major chronic infectious and non-communicable diseases in the public sector. To identify the causes of stock-outs and to illustrate how they undermine access to medicines (ATM) in the Western Cape Province, SA. This qualitative study was conducted with a sample of over 70 key informants (frontline health workers, sub-structure and provincial health service managers). We employed the critical incident technique to identify significant occurrences in our context, the consequences of which impacted on access to medicines during a defined period. Stock-outs were identified as one such incident, and we explored when, where and why they occurred, in order to inform policy and practice. Medicines procurement is a centralised function in SA. Health service managers unanimously agreed that stock-outs resulted from the following inefficiencies at the central level: (i) delays in awarding of pharmaceutical tenders; (ii) absence of contracts for certain medicines appearing on provincial code lists; and (iii) suppliers' inability to satisfy contractual agreements. The recurrence of stock-outs had implications at multiple levels: (i) health facility operations; (ii) the Chronic Dispensing Unit (CDU), which prepacks medicines for over 300 000 public sector patients; and (iii) community-based medicines distribution systems, which deliver the CDU's prepacked medicines to non-health facilities nearer to patient homes. For instance, stock-outs resulted in omission of certain medicines from CDU parcels that were delivered to health facilities. This increased workload and caused frustration for frontline health workers who were expected to dispense omitted medicines manually. According to frontline health workers, this translated into longer waiting times for patients and associated dissatisfaction. In some instances, patients were asked to return for undispensed medication at a later date, which could potentially affect adherence to treatment and therapeutic outcomes. Stock-outs therefore undermined the intended benefits of ATM strategies. Addressing the procurement challenges, most notably timeous tender awards and supplier performance management, is critical for successful implementation of ATM strategies.
Inferential control -- Part 1: Crude unit advanced controls pass accuracy and repeatability tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
San, Y.P.; Landells, K.C.; Mackay, D.C.
1994-11-28
An inferential model is one that provides a quality for which an analyzer is not available. This type of model uses readily available physical measurements -- such as temperatures, pressures, and flow rates -- to infer a quality such as kerosine flash point. The No. 2 crude distillation unit (CDU-2) at Singapore Refining Co. Pte. Ltd.'s Pulau Merlimau refinery has a nominal 130,000 b/d capacity. It produces naphtha, kerosine, diesel, and residue products from a wide range of crude blends. Over the past 12 months, extensive advanced control applications have been implemented on the unit. This first of two articlesmore » will describe the control system and its implementation. The second will outline the project's achievements, including reduced quality giveaway and increased profits. The paper describes background of the company and unit, the process, project implementation, the Infer model, model tuning, closed-loop control, feed rate maximization, and economic monitoring.« less
Ocular Blood Flow Changes in Behçet Disease Patients with/without Thrombotic Disease
Yüksel, Harun; Türkcü, Fatih M.; Hamidi, Cihat; Cingü, Abdullah K.; Çinar, Yasin; Şahin, Muhammed; Özkurt, Zeynep; Çaça, İhsan
2014-01-01
ABSTRACT In this study, the authors aimed to evaluate ocular blood flow changes in Behçet disease (BD) with and without thrombotic disease. Ninety eyes of 90 patients with a diagnosis of BD (30 eyes with active uveitis, 23 eyes with inactive uveitis, 25 eyes without ocular involvement, and 12 eyes without ocular involvement and with a history of thrombosis) and 30 eyes of 30 age- and sex-matched control patients without any systemic disease with a total of 120 eyes were evaluated. In all cases, ophthalmic, central retinal, and ciliary artery flow parameters were measured with colour Doppler ultrasonography (CDU). The ocular blood flow parameters of all vessels in patients with active uveitis were found to be affected. All the flow parameters in the CRAs of the study groups were significantly different from the control group (p < 0.001). Additionally, in non-ocular BD patients with thrombosis, blood flow parameters were affected more than the parameters in non-ocular BD patients without thrombosis and control patients. In conclusion, major haemodynamic changes were observed using CDU in the ophthalmic vessels of ocular Behçet patients. Also, CDU may detect ocular blood flow alterations before initial ocular clinical manifestations appear in BD patients PMID:27928286
Ocular Blood Flow Changes in Behçet Disease Patients with/without Thrombotic Disease.
Yüksel, Harun; Türkcü, Fatih M; Hamidi, Cihat; Cingü, Abdullah K; Çinar, Yasin; Şahin, Muhammed; Özkurt, Zeynep; Çaça, İhsan
2014-01-01
In this study, the authors aimed to evaluate ocular blood flow changes in Behçet disease (BD) with and without thrombotic disease. Ninety eyes of 90 patients with a diagnosis of BD (30 eyes with active uveitis, 23 eyes with inactive uveitis, 25 eyes without ocular involvement, and 12 eyes without ocular involvement and with a history of thrombosis) and 30 eyes of 30 age- and sex-matched control patients without any systemic disease with a total of 120 eyes were evaluated. In all cases, ophthalmic, central retinal, and ciliary artery flow parameters were measured with colour Doppler ultrasonography (CDU). The ocular blood flow parameters of all vessels in patients with active uveitis were found to be affected. All the flow parameters in the CRAs of the study groups were significantly different from the control group ( p < 0.001). Additionally, in non-ocular BD patients with thrombosis, blood flow parameters were affected more than the parameters in non-ocular BD patients without thrombosis and control patients. In conclusion, major haemodynamic changes were observed using CDU in the ophthalmic vessels of ocular Behçet patients. Also, CDU may detect ocular blood flow alterations before initial ocular clinical manifestations appear in BD patients.
Opto-acoustic image fusion technology for diagnostic breast imaging in a feasibility study
NASA Astrophysics Data System (ADS)
Zalev, Jason; Clingman, Bryan; Herzog, Don; Miller, Tom; Ulissey, Michael; Stavros, A. T.; Oraevsky, Alexander; Lavin, Philip; Kist, Kenneth; Dornbluth, N. C.; Otto, Pamela
2015-03-01
Functional opto-acoustic (OA) imaging was fused with gray-scale ultrasound acquired using a specialized duplex handheld probe. Feasibility Study findings indicated the potential to more accurately characterize breast masses for cancer than conventional diagnostic ultrasound (CDU). The Feasibility Study included OA imagery of 74 breast masses that were collected using the investigational Imagio® breast imaging system. Superior specificity and equal sensitivity to CDU was demonstrated, suggesting that OA fusion imaging may potentially obviate the need for negative biopsies without missing cancers in a certain percentage of breast masses. Preliminary results from a 100 subject Pilot Study are also discussed. A larger Pivotal Study (n=2,097 subjects) is underway to confirm the Feasibility Study and Pilot Study findings.
Lumsden, Sarah; Rosta, Gabor; Bismuth, Jean; Lumsden, Alan B.; Garami, Zsolt
2017-01-01
Dissection of the internal carotid artery (ICA) accounts for 5% to 25% of ischemic strokes in young adults. We report a case of spontaneous recanalization of a traumatic ICA dissection in which carotid duplex (CDU) and transcranial color-coded duplex ultrasound (TCCD) were used. A 47-year-old male presented with intermittent episodes of headache, blurry vision, anisocoria, and loss of taste sensation following a whiplash injury while body surfing. Magnetic resonance angiogram (MRA) of the neck revealed absent flow in the cavernous ICA and a clot at the skull base. Carotid duplex, used to further evaluate flow, demonstrated reverberating color Doppler and spectrum signal. A TCCD showed ICA occlusion and smaller-caliber intracranial ICA. The patient reported for follow-up after 1 month on anticoagulation therapy. Upon his return, CDU and TCCD were normal and the ICA showed normal color and spectrum signals. Computed tomography angiogram confirmed ultrasound findings of a dramatic improvement of ICA patency. Additionally, the patient reported that his headaches had resolved. Extracranial CDU and TCCD are useful for monitoring patient progress in cases of spontaneous recanalization following carotid artery dissection. These inexpensive and noninvasive imaging modalities proved to be critical in the initial and follow-up evaluations of the extracranial and intracranial vascular system, providing a strong alternative to expensive magnetic resonance imaging and invasive angiograms and offering more hemodynamic information than “static” MRA. PMID:29744017
Okur, A; Kantarci, M; Karaca, L; Yildiz, S; Sade, R; Pirimoglu, B; Keles, M; Avci, A; Çankaya, E; Schmitt, P
2016-03-01
To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Designing an Innovative Data Architecture for the Los Angeles Data Resource (LADR).
Mukherjee, Sukrit; Jenders, Robert A; Delta, Sebastien
2015-01-01
The Los Angeles Data Resource (LADR) is a joint project of major Los Angeles health care provider organizations. The LADR helps clinical investigators to explore the size of potential research study cohorts using operational clinical data across all participating institutions. The Charles R. Drew University of Medicine and Science (CDU) LADR team sought to develop an innovative data architecture that would aggregate de-identified clinical data from safety-net providers in the community into CDU LADR node. This in turn would be federated with the other nodes of LADR for a shared view in a way that was never available before. This led to a self-service system to assess patients matching study criteria at each medical center and to search patients by demographics, ICD-9 codes, lab results and medications.
Investigation of hyper-NA scanner emulation for photomask CDU performance
NASA Astrophysics Data System (ADS)
Poortinga, Eric; Scheruebl, Thomas; Conley, Will; Sundermann, Frank
2007-02-01
As the semiconductor industry moves toward immersion lithography using numerical apertures above 1.0 the quality of the photomask becomes even more crucial. Photomask specifications are driven by the critical dimension (CD) metrology within the wafer fab. Knowledge of the CD values at resist level provides a reliable mechanism for the prediction of device performance. Ultimately, tolerances of device electrical properties drive the wafer linewidth specifications of the lithography group. Staying within this budget is influenced mainly by the scanner settings, resist process, and photomask quality. Tightening of photomask specifications is one mechanism for meeting the wafer CD targets. The challenge lies in determining how photomask level metrology results influence wafer level imaging performance. Can it be inferred that photomask level CD performance is the direct contributor to wafer level CD performance? With respect to phase shift masks, criteria such as phase and transmission control are generally tightened with each technology node. Are there other photomask relevant influences that effect wafer CD performance? A comprehensive study is presented supporting the use of scanner emulation based photomask CD metrology to predict wafer level within chip CD uniformity (CDU). Using scanner emulation with the photomask can provide more accurate wafer level prediction because it inherently includes all contributors to image formation related to the 3D topography such as the physical CD, phase, transmission, sidewall angle, surface roughness, and other material properties. Emulated images from different photomask types were captured to provide CD values across chip. Emulated scanner image measurements were completed using an AIMS TM45-193i with its hyper-NA, through-pellicle data acquisition capability including the Global CDU Map TM software option for AIMS TM tools. The through-pellicle data acquisition capability is an essential prerequisite for capturing final CDU data (after final clean and pellicle mounting) before the photomask ships or for re-qualification at the wafer fab. Data was also collected on these photomasks using a conventional CD-SEM metrology system with the pellicles removed. A comparison was then made to wafer prints demonstrating the benefit of using scanner emulation based photomask CD metrology.
Stability and imaging of the ASML EUV alpha demo tool
NASA Astrophysics Data System (ADS)
Hermans, Jan V.; Baudemprez, Bart; Lorusso, Gian; Hendrickx, Eric; van Dijk, Andre; Jonckheere, Rik; Goethals, Anne-Marie
2009-03-01
Extreme Ultra-Violet (EUV) lithography is the leading candidate for semiconductor manufacturing of the 22nm technology node and beyond, due to the very short wavelength of 13.5nm. However, reducing the wavelength adds complexity to the lithographic process. The impact of the EUV specific conditions on lithographic performance needs to be understood, before bringing EUV lithography into pre-production. To provide early learning on EUV, an EUV fullfield scanner, the Alpha Demo Tool (ADT) from ASML was installed at IMEC, using a Numerical Aperture (NA) of 0.25. In this paper we report on different aspects of the ADT: the imaging and overlay performance and both short and long-term stability. For 40nm dense Lines-Spaces (LS), the ADT shows an across field overlapping process window of 270nm Depth Of Focus (DOF) at 10% Exposure Latitude (EL) and a wafer CD Uniformity (CDU) of 3nm 3σ, without any corrections for process or reticle. The wafer CDU is correlated to different factors that are known to influence the CD fingerprint from traditional lithography: slit intensity uniformity, focus plane deviation and reticle CD error. Taking these contributions into account, the CD through slit fingerprint for 40nm LS is simulated with excellent agreement to experimental data. The ADT shows good CD stability over 9 months of operation, both intrafield and across wafer. The projection optics reflectivity has not degraded over 9 months. Measured overlay performance with respect to a dry tool shows |Mean|+3σ below 20nm with more correction potential by applying field-by-field corrections (|Mean|+3σ <=10nm). For 22nm SRAM application, both contact hole and metal layer were printed in EUV with 10% CD and 15nm overlay control. Below 40nm, the ADT shows good wafer CDU for 30nm dense and isolated lines (on the same wafer) and 38nm dense Contact Holes (CH). First 28nm dense line CDU data are achieved. The results indicate that the ADT can be used effectively for EUV process development before installation of the pre-production tool, the ASML NXE Gen. 1 at IMEC.
Understanding the critical challenges of self-aligned octuple patterning
NASA Astrophysics Data System (ADS)
Yu, Ji; Xiao, Wei; Kang, Weiling; Chen, Yijian
2014-03-01
In this paper, we present a thorough investigation of self-aligned octuple patterning (SAOP) process characteristics, cost structure, integration challenges, and layout decomposition. The statistical characteristics of SAOP CD variations such as multi-modality are analyzed and contributions from various features to CDU and MTT (mean-to-target) budgets are estimated. The gap space is found to have the worst CDU+MTT performance and is used to determine the required overlay accuracy to ensure a satisfactory edge-placement yield of a cut process. Moreover, we propose a 5-mask positive-tone SAOP (pSAOP) process for memory FEOL patterning and a 3-mask negative-tone SAOP (nSAOP) process for logic BEOL patterning. The potential challenges of 2-D SAOP layout decomposition for BEOL applications are identified. Possible decomposition approaches are explored and the functionality of several developed algorithm is verified using 2-D layout examples from Open Cell Library.
Erectile function after anastomotic urethroplasty for pelvic fracture urethral injuries.
El-Assmy, A; Harraz, A M; Benhassan, M; Nabeeh, A; Ibrahiem, El Hi
2016-07-01
There is an established association between ED and pelvic fracture urethral injuries (PFUIs). However, ED can occur after the injury and/or the urethral repair. To our knowledge, only one study of erectile function (EF) after urethroplasty for PFUIs used a validated questionnaire. This study was carried out to determine the impact of anastomotic posterior urethroplasty for PFUIs on EF. We retrospectively reviewed the computerized surgical records to identify patients who underwent anastomotic urethroplasty for PFUIs from 1998 to 2014. Those patients were contacted by phone or mail and were re-evaluated in the outpatient clinic by International Index of Erectile Function questionnaire; in unmarried men, the single-question self-report of ED was used for evaluation of EF, clinical examination and penile color Doppler ultrasonography (CDU) for men with ED. Overall, 58 patients were included in the study among whom 36 (62%) men were sexually active and the remaining 22 (38%) were single. The incidence of ED among our group is 72%. All patients developed ED after initial pelvic trauma and none of our patients had impaired EF after urethroplasty. The incidence of ED increased proportionally with severity of pelvic trauma. All patients with type-C pelvic fracture, associated symphysis pubis diastasis, sacroiliac joints diastasis and bilateral pubic ramus fractures had ED. Men with PFUIs had worse EF than men in other series with pelvic fractures without urethral injury. The majority (88%) of men with ED showed veno-occlusive dysfunction on penile CDU. So we concluded that men with PFUIs had a high incidence of ED up to 72%. Anastomotic posterior urethroplasty had no negative impact on EF and the development of ED after PFUIs was related to the severity of the original pelvic trauma. Veno-occlusive dysfunction is the commonest etiology of ED on penile CDU.
Alonso-Moreno, Carlos; García-Yuste, Santiago
2016-10-15
A novel Carbon Dioxide Utilization (CDU) approach from a relatively minor CO2 emission source, i.e., alcoholic fermentation processes (AFP), is presented. The CO2 produced as a by-product from the AFP is estimated by examining the EtOH consumed per year reported by the World Health Organization in 2014. It is proposed that the extremely pure CO2 from the AFP is captured in NaOH solutions to produce one of the Top 10 commodities in the chemical industry, Na2CO3, as a good example of an atomic economy process. The novel CDU strategy could yield over 30.6Mt of Na2CO3 in oversaturated aqueous solution on using ca. 12.7Mt of captured CO2 and this process would consume less energy than the synthetic methodology (Solvay ammonia soda process) and would not produce low-value by-products. The quantity of Na2CO3 obtained by this strategy could represent ca. 50% of the world Na2CO3 production in one year. In terms of the green economy, the viability of the strategy is discussed according to the recommendations of the CO2Chem network, and an estimation of the CO2negative emission achieved suggests a capture of around 280.0Mt of CO2 from now to 2020 or ca. 1.9Gt from now to 2050. Finally, the results obtained for this new CDU proposal are discussed by considering different scenarios; the CO2 production in a typical winemaking corporation, the CO2 released in the most relevant wine-producing countries, and the use of CO2 from AFP as an alternative for the top Na2CO3-producing countries. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickes, R.W. Jr.; Wackerbarth, D.E.; Mohler, J.H.
1996-12-31
The authors report on recent studies comparing the ignition threshold of temperature cycled, SCB thermite devices with units that were not submitted to temperature cycling. Aluminum/copper-oxide thermite was pressed into units at two densities, 45% of theoretical maximum density (TMD) or 47% of TMD. Half of each of the density sets underwent three thermal cycles; each cycle consisted of 2 hours at 74 C and 2 hours at {minus}54 C, with a 5 minute maximum transfer time between temperatures. The temperature cycled units were brought to ambient temperature before the threshold testing. Both the density and the thermal cycling affectedmore » the all-fire voltage. Using a 5.34 {micro}F CDU (capacitor discharge unit) firing set, the all-fire voltage for the units that were not temperature cycled increased with density from 32.99 V (45% TMD) to 39.32 V (47% TMD). The all-fire voltages for the thermally cycled units were 34.42 V (45% TMD) and 58.1 V (47% TMD). They also report on no-fire levels at ambient temperature for two component designs; the 5 minute no-fire levels were greater than 1.2 A. Units were also subjected to tests in which 1 W of RF power was injected into the bridges at 10 MHz for 5 minutes. The units survived and fired normally afterwards. Finally, units were subjected to pin-to-pin electrostatic discharge (ESD) tests. None of the units fired upon application of the ESD pulse, and all of the tested units fired normally afterwards.« less
West German NATO Policy: The Next Five Years
1989-11-01
West German conservatives have been confronted by the rise of the Republican party on the radical right . The causes underlying such political shifts...rise of the radical right Republican party, initially founded in Bavaria by several deputies from the the CDU’s sister party, the Christian Social
A low-ignition energy, SCB, thermite igniter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickes, R.W. Jr.; Grubelich, M.C.; Wackerbarth, D.E.
1996-06-01
The authors describe threshold ignition studies for semiconductor bridge, SCB, ignition of aluminum/copper oxide (Al/CuO) thermite as a function of the capacitor discharge unit (CDU) firing set discharge capacitance, the charge holder material and the morphology of the CuO. All of the tests were carried out with the devices cooled to 0 F ({minus}18 C). They compared ignition thresholds using a brass charge holder and a G10 charge holder; G10 is a non-conducting, fiber-glass-epoxy composite material. They determined that at 50 V on the discharge capacitor, the thresholds were 30.1 {micro}F and 2.0 {micro}F respectively. The tests revealed that differentmore » CuO morphologies affected the function time (interval between start of the firing set current and the output of the thermite device) but did not significantly affect the threshold sensitivity.« less
van Lent, Wineke A M; de Beer, Relinde D; van Harten, Wim H
2010-08-31
Benchmarking is one of the methods used in business that is applied to hospitals to improve the management of their operations. International comparison between hospitals can explain performance differences. As there is a trend towards specialization of hospitals, this study examines the benchmarking process and the success factors of benchmarking in international specialized cancer centres. Three independent international benchmarking studies on operations management in cancer centres were conducted. The first study included three comprehensive cancer centres (CCC), three chemotherapy day units (CDU) were involved in the second study and four radiotherapy departments were included in the final study. Per multiple case study a research protocol was used to structure the benchmarking process. After reviewing the multiple case studies, the resulting description was used to study the research objectives. We adapted and evaluated existing benchmarking processes through formalizing stakeholder involvement and verifying the comparability of the partners. We also devised a framework to structure the indicators to produce a coherent indicator set and better improvement suggestions. Evaluating the feasibility of benchmarking as a tool to improve hospital processes led to mixed results. Case study 1 resulted in general recommendations for the organizations involved. In case study 2, the combination of benchmarking and lean management led in one CDU to a 24% increase in bed utilization and a 12% increase in productivity. Three radiotherapy departments of case study 3, were considering implementing the recommendations.Additionally, success factors, such as a well-defined and small project scope, partner selection based on clear criteria, stakeholder involvement, simple and well-structured indicators, analysis of both the process and its results and, adapt the identified better working methods to the own setting, were found. The improved benchmarking process and the success factors can produce relevant input to improve the operations management of specialty hospitals.
2010-01-01
Background Benchmarking is one of the methods used in business that is applied to hospitals to improve the management of their operations. International comparison between hospitals can explain performance differences. As there is a trend towards specialization of hospitals, this study examines the benchmarking process and the success factors of benchmarking in international specialized cancer centres. Methods Three independent international benchmarking studies on operations management in cancer centres were conducted. The first study included three comprehensive cancer centres (CCC), three chemotherapy day units (CDU) were involved in the second study and four radiotherapy departments were included in the final study. Per multiple case study a research protocol was used to structure the benchmarking process. After reviewing the multiple case studies, the resulting description was used to study the research objectives. Results We adapted and evaluated existing benchmarking processes through formalizing stakeholder involvement and verifying the comparability of the partners. We also devised a framework to structure the indicators to produce a coherent indicator set and better improvement suggestions. Evaluating the feasibility of benchmarking as a tool to improve hospital processes led to mixed results. Case study 1 resulted in general recommendations for the organizations involved. In case study 2, the combination of benchmarking and lean management led in one CDU to a 24% increase in bed utilization and a 12% increase in productivity. Three radiotherapy departments of case study 3, were considering implementing the recommendations. Additionally, success factors, such as a well-defined and small project scope, partner selection based on clear criteria, stakeholder involvement, simple and well-structured indicators, analysis of both the process and its results and, adapt the identified better working methods to the own setting, were found. Conclusions The improved benchmarking process and the success factors can produce relevant input to improve the operations management of specialty hospitals. PMID:20807408
Asetek's Warm-Water Liquid Cooling System Yields Energy Cost Savings at
NREL | Energy Systems Integration Facility | NREL Asetek Asetek's Warm-Water Liquid Cooling System Yields Energy Cost Savings at NREL Asetek's RackCDU liquid cooling system was installed and tested at the Energy Systems Integration Facility's (ESIF's) ultra-energy-efficient high-performance
Theory of Mind Impairments in Women With Cocaine Addiction.
Sanvicente-Vieira, Breno; Kluwe-Schiavon, Bruno; Corcoran, Rhiannon; Grassi-Oliveira, Rodrigo
2017-03-01
This study investigates the Theory of Mind performance of female cocaine-dependent users (CDUs) and possible associations between theory of mind performance and features of cocaine use. Sixty women controlled for age, education, individual income, and IQ participated in this study: 30 in the CDU group and 30 in the healthy control group. Participants were assessed for theory of mind with the Reading the Mind in the Eyes Test (RMET), a test of understanding of first-order and second-order false beliefs, and the Hinting task. Drug use parameters, clinical symptoms, and neuropsychological functioning were also assessed. Analyses of covariance indicated Theory of Mind impairments in negative mental states within the RMET and second-order false-belief understanding of Theory of Mind stories. In addition, Theory of Mind impairment was associated with drug use characteristics, including craving and number of hospitalizations. High-demand Theory of Mind is suggested to be impaired in CDU women, and the deficits appear to be related to drug addiction severity. We found associations between Theory of Mind deficits and worse clinical and social outcomes.
McCaffrey, Nikki; Agar, Meera; Harlum, Janeane; Karnon, Jonathon; Currow, David; Eckermann, Simon
2015-01-01
Introduction Comparing multiple, diverse outcomes with cost-effectiveness analysis (CEA) is important, yet challenging in areas like palliative care where domains are unamenable to integration with survival. Generic multi-attribute utility values exclude important domains and non-health outcomes, while partial analyses—where outcomes are considered separately, with their joint relationship under uncertainty ignored—lead to incorrect inference regarding preferred strategies. Objective The objective of this paper is to consider whether such decision making can be better informed with alternative presentation and summary measures, extending methods previously shown to have advantages in multiple strategy comparison. Methods Multiple outcomes CEA of a home-based palliative care model (PEACH) relative to usual care is undertaken in cost disutility (CDU) space and compared with analysis on the cost-effectiveness plane. Summary measures developed for comparing strategies across potential threshold values for multiple outcomes include: expected net loss (ENL) planes quantifying differences in expected net benefit; the ENL contour identifying preferred strategies minimising ENL and their expected value of perfect information; and cost-effectiveness acceptability planes showing probability of strategies minimising ENL. Results Conventional analysis suggests PEACH is cost-effective when the threshold value per additional day at home ( 1) exceeds $1,068 or dominated by usual care when only the proportion of home deaths is considered. In contrast, neither alternative dominate in CDU space where cost and outcomes are jointly considered, with the optimal strategy depending on threshold values. For example, PEACH minimises ENL when 1=$2,000 and 2=$2,000 (threshold value for dying at home), with a 51.6% chance of PEACH being cost-effective. Conclusion Comparison in CDU space and associated summary measures have distinct advantages to multiple domain comparisons, aiding transparent and robust joint comparison of costs and multiple effects under uncertainty across potential threshold values for effect, better informing net benefit assessment and related reimbursement and research decisions. PMID:25751629
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakhshandeh, Mohsen; Hashemi, Bijan, E-mail: bhashemi@modares.ac.ir; Mahdavi, Seyed Rabie
2012-05-01
Purpose: To evaluate thyroid function and vascular changes during radiotherapy for patients with head and neck cancer. Methods and Materials: Fifty patients treated with primary or postoperative radiotherapy for various cancers in the head and neck region were prospectively evaluated. The serum samples (triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH], free triiodothyronine [FT3], and free thyroxine [FT4]), the echo level of the thyroid gland, and color Doppler ultrasonography (CDU) parameters of the right inferior thyroid artery (RITA) of the patients were measured before and at regular intervals during radiotherapy. The thyroid gland dose-volume histograms of the patients were derived frommore » their computed tomography-based treatment plans. Results: There was a significant fall in TSH level (p < 0.0001) but an increase in FT4 (p < 0.0001) and T4 (p < 0.022) levels during the radiotherapy course. The threshold dose required to produce significant changes was 12 Gy (Biologically Effective Dose in 2-Gy fractions, BED{sub 2}). There were significant rises in the patients' pulsatility index, resistive index, peak systolic velocity, blood volume flow levels, and RITA diameter (p < 0.0001), as detected by CDU during radiotherapy, compared to those parameters measured before the treatment. Hypoechogenicity and irregular echo patterns (p < 0.0001) were seen during radiotherapy compared to those before treatment. There was significant Pearson's correlation between the CDU parameters and T4, FT4, and TSH levels. Conclusions: Radiation-induced thyroiditis is regarded as primary damage to the thyroid gland. Thyroiditis can subsequently result in hypothyroidism or hyperthyroidism. Our results demonstrated that changes in thyroid vessels occur during radiotherapy delivered to patients. Vessel changes also can be attributed to the late effect of radiation on the thyroid gland. The hypoechogenicity and irregular echo patterns observed in patients may result from the increase in intrathyroidal flow.« less
Developing Fully Online Pre-Service Music and Arts Education Courses
ERIC Educational Resources Information Center
Lierse, Sharon
2015-01-01
Charles Darwin University (CDU) offers education courses for students who want to teach in Australian schools. The university is unique due to its geographic location, proximity to Asia and its high Indigenous population compared to the rest of the country. Many courses are offered fully online including music education for pre-service teachers.…
Adult Literacy and Socio-Cultural Learning at "Pina Pina Jarrinjaku" (Yuendumu Learning Centre)
ERIC Educational Resources Information Center
Bauer, Ros
2018-01-01
The Whole of Community Engagement (WCE) initiative commenced in July 2014, led by the Office of Pro Vice Chancellor of Indigenous Leadership at Charles Darwin University (CDU). WCE aimed to build the aspiration, expectation and capacity of six remote and very remote Indigenous communities in the Northern Territory to participate and achieve in…
NASA Technical Reports Server (NTRS)
Cook, J. P. (Principal Investigator); Stringer, W. J.
1974-01-01
The author has identified the following significant results. The objective is to determine the feasibility of detecting large Alaskan archaeological sites by satellite remote sensing techniques and mapping such sites. The approach used is to develop digital multispectral signatures of dominant surface features including vegetation, exposed soils and rock, hydrological patterns and known archaeological sites. ERTS-1 scenes are then printed out digitally in a map-like array with a letter reflecting the most appropriate classification representing each pixel. Preliminary signatures were developed and tested. It was determined that there was a need to tighten up the archaeological site signature by developing accurate signatures for all naturally-occurring vegetation and surface conditions in the vicinity of the test area. These second generation signatures have been tested by means of computer printouts and classified tape displays on the University of Alaska CDU-200 and by comparison with aerial photography. It has been concluded that the archaeological signatures now in use are as good as can be developed. Plans are to print out signatures for the entire test area and locate on topographic maps the likely locations of archaeological sites within the test area.
Wafer hot spot identification through advanced photomask characterization techniques
NASA Astrophysics Data System (ADS)
Choi, Yohan; Green, Michael; McMurran, Jeff; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike
2016-10-01
As device manufacturers progress through advanced technology nodes, limitations in standard 1-dimensional (1D) mask Critical Dimension (CD) metrics are becoming apparent. Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that the classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on subresolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. These items are not quantifiable with the 1D metrology techniques of today. Likewise, the mask maker needs advanced characterization methods in order to optimize the mask process to meet the wafer lithographer's needs. These advanced characterization metrics are what is needed to harmonize mask and wafer processes for enhanced wafer hot spot analysis. In this paper, we study advanced mask pattern characterization techniques and their correlation with modeled wafer performance.
El-Assmy, A; El-Tholoth, H S; Abou-El-Ghar, M E; Mohsen, T; Ibrahiem, E H I
2012-01-01
This study was conducted to determine the preoperative and intraoperative risk factors of ED and the underlying penile vascular abnormalities among patients with penile fracture treated surgically. In all, 180 patients with penile fracture were treated surgically and followed up in one center. None of our patients had ED before the penile trauma and only two of them had risk factors for systemic vascular diseases, such as diabetes mellitus (one patient) and hypertension (one patient). After a mean follow-up of 106 months, 11 patients (6.6%) developed ED, 7 had mild ED and 4 had moderate ED. The main risk factors for subsequent ED were aging, >50 years, and bilateral corporal involvement. Among the 11 patients with ED, color Doppler ultrasonography (CDU) showed normal Doppler indices in 4 (36.4%), veno-occlusive dysfunction in 4 (36.4%) and arterial insufficiency in the remaining 3 (27.2%) patients. CDU assessments from the injured and intact sides were comparable. ED of either a psychological or vascular origin can be encountered as a long-term sequel of surgical treatment of penile fracture. Aging, >50 years, at presentation and bilateral corporal involvement is the main risk factors for subsequent development of ED.
Selective Formation of Trimethylene Carbonate (TMC): Atmospheric Pressure Carbon Dioxide Utilization
Buckley, Benjamin R; Patel, Anish P; Wijayantha, K G Upul
2015-01-01
Carbon dioxide utilisation (CDU) is currently gaining increased interest due to the abundance of CO2 and its possible application as a C1 building block. We herein report the first example of atmospheric pressure carbon dioxide incorporation into oxetane to selectively form trimethylene carbonate (TMC), which is a significant challenge as TMC is thermodynamically less favoured than its corresponding co-polymer. PMID:26213485
Buckley, Benjamin R; Patel, Anish P; Wijayantha, K G Upul
2015-01-01
Carbon dioxide utilisation (CDU) is currently gaining increased interest due to the abundance of CO 2 and its possible application as a C 1 building block. We herein report the first example of atmospheric pressure carbon dioxide incorporation into oxetane to selectively form trimethylene carbonate (TMC), which is a significant challenge as TMC is thermodynamically less favoured than its corresponding co-polymer.
Optimum ArFi laser bandwidth for 10nm node logic imaging performance
NASA Astrophysics Data System (ADS)
Alagna, Paolo; Zurita, Omar; Timoshkov, Vadim; Wong, Patrick; Rechtsteiner, Gregory; Baselmans, Jan; Mailfert, Julien
2015-03-01
Lithography process window (PW) and CD uniformity (CDU) requirements are being challenged with scaling across all device types. Aggressive PW and yield specifications put tight requirements on scanner performance, especially on focus budgets resulting in complicated systems for focus control. In this study, an imec N10 Logic-type test vehicle was used to investigate the E95 bandwidth impact on six different Metal 1 Logic features. The imaging metrics that track the impact of light source E95 bandwidth on performance of hot spots are: process window (PW), line width roughness (LWR), and local critical dimension uniformity (LCDU). In the first section of this study, the impact of increasing E95 bandwidth was investigated to observe the lithographic process control response of the specified logic features. In the second section, a preliminary assessment of the impact of lower E95 bandwidth was performed. The impact of lower E95 bandwidth on local intensity variability was monitored through the CDU of line end features and the LWR power spectral density (PSD) of line/space patterns. The investigation found that the imec N10 test vehicle (with OPC optimized for standard E95 bandwidth of300fm) features exposed at 200fm showed pattern specific responses, suggesting areas of potential interest for further investigation.
NASA Technical Reports Server (NTRS)
Johnson, Walter W.; Lachter, Joel B.; Battiste, Vernol; Lim, Veranika; Brandt, Summer L.; Koteskey, Robert W.; Dao, Arik-Quang V.; Ligda, Sarah V.; Wu, Shu-Chieh
2011-01-01
A primary feature of the Next Generation Air Transportation System (NextGen) is trajectory based operations (TBO). Under TBO, aircraft flight plans are known to computer systems on the ground that aid in scheduling and separation. The Future Air Navigation System (FANS) was developed to support TBO, but relatively few aircraft in the US are FANSequipped. Thus, any near-term implementation must provide TBO procedures for non-FANS aircraft. Previous research has explored controller clearances, but any implementation must also provide procedures for aircraft requests. The work presented here aims to surface issues surrounding TBO communication procedures for non-FANS aircraft and for aircraft requesting deviations around weather. Three types of communication were explored: Voice, FANS, and ACARS,(Aircraft Communications Addressing and Reporting System). ACARS and FANS are datacom systems that differ in that FANS allows uplinked flight plans to be loaded into the Flight Management System (FMS), while ACARS delivers flight plans as text that must be entered manually via the Control Display Unit (CDU). Sixteen pilots (eight two-person flight decks) and four controllers participated in 32 20-minute scenarios that required the flight decks to navigate through convective weather as they approached their top of descents (TODs). Findings: The rate of non-conformance was higher than anticipated, with aircraft off path more than 20% of the time. Controllers did not differentiate between the ACARS and FANS datacom, and were mixed in their preference for Voice vs. datacom (ACARS and FANS). Pilots uniformly preferred Voice to datacom, particularly ACARS. Much of their dislike appears to result from the slow response times in the datacom conditions. As a result, participants frequently resorted to voice communication. These results imply that, before implementing TBO in environments where pilots make weather deviation requests, further research is needed to develop communication procedures that integrate voice and datacom.
1990-05-10
dismantled. Coeducation of "normal" and disabled chil- The CDU supports developing the opportunity of every dren and adolescents in school can be one...for the cannot be politically right. Respect of ethical principles, benefit of the people requires clear positions, and at the even in the area of...tance in terms of social benefits , and human quality when these nuances are not domi- "* We strive for granting full credit for purposes of job nated
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. Center for Vocational Education.
This package of camera ready masters is one of a set of twelve documents describing the Career Planning Support System (CPSS) and its use. (CPSS is a comprehensive guidance program management system which (1) provides techniques to improve a high school's career guidance program, (2) focuses on the skills students need to make decisions about and…
Emotional display rules as work unit norms: a multilevel analysis of emotional labor among nurses.
Diefendorff, James M; Erickson, Rebecca J; Grandey, Alicia A; Dahling, Jason J
2011-04-01
Emotional labor theory has conceptualized emotional display rules as shared norms governing the expression of emotions at work. Using a sample of registered nurses working in different units of a hospital system, we provided the first empirical evidence that display rules can be represented as shared, unit-level beliefs. Additionally, controlling for the influence of dispositional affectivity, individual-level display rule perceptions, and emotion regulation, we found that unit-level display rules are associated with individual-level job satisfaction. We also showed that unit-level display rules relate to burnout indirectly through individual-level display rule perceptions and emotion regulation strategies. Finally, unit-level display rules also interacted with individual-level dispositional affectivity to predict employee use of emotion regulation strategies. We discuss how future research on emotional labor and display rules, particularly in the health care setting, can build on these findings.
Integrated scatterometry for tight overlay and CD control to enable 20-nm node wafer manufacturing.
NASA Astrophysics Data System (ADS)
Benschop, Jos; Engelen, Andre; Cramer, Hugo; Kubis, Michael; Hinnen, Paul; van der Laan, Hans; Bhattacharyya, Kaustuve; Mulkens, Jan
2013-04-01
The overlay, CDU and focus requirements for the 20nm node can only be met using a holistic lithography approach whereby full use is made of high-order, field-by-field, scanner correction capabilities. An essential element in this approach is a fast, precise and accurate in-line metrology sensor, capable to measure on product. The capabilities of the metrology sensor as well as the impact on overlay, CD and focus will be shared in this paper.
Obscuration Code with Space Station Applications (Manual)
1985-12-01
used to perform this DCL style com - mand parsing, readers are referred to the VMS documentation concerning the Command Definition Utility or CDU. I I I...FOR0O7.DAT; Input echo file: USERI: [RJM.NASJAN5S1 .LIS;3 The above examples show the operation of the SET OUTPUT com - mand. Note that the printer file is...be opened using the SET OUTPUT com - mand. The output files can be opened and closed using the SET OUTPUT /ECHOING, /PRINTABLE, /PLOTTABLE commands
Wireless, relative-motion computer input device
Holzrichter, John F.; Rosenbury, Erwin T.
2004-05-18
The present invention provides a system for controlling a computer display in a workspace using an input unit/output unit. A train of EM waves are sent out to flood the workspace. EM waves are reflected from the input unit/output unit. A relative distance moved information signal is created using the EM waves that are reflected from the input unit/output unit. Algorithms are used to convert the relative distance moved information signal to a display signal. The computer display is controlled in response to the display signal.
NASA Astrophysics Data System (ADS)
Morozov, Alexander; Dubinin, German; Dubynin, Sergey; Yanusik, Igor; Kim, Sun Il; Choi, Chil-Sung; Song, Hoon; Lee, Hong-Seok; Putilin, Andrey; Kopenkin, Sergey; Borodin, Yuriy
2017-06-01
Future commercialization of glasses-free holographic real 3D displays requires not only appropriate image quality but also slim design of backlight unit and whole display device to match market needs. While a lot of research aimed to solve computational issues of forming Computer Generated Holograms for 3D Holographic displays, less focus on development of backlight units suitable for 3D holographic display applications with form-factor of conventional 2D display systems. Thereby, we report coherent backlight unit for 3D holographic display with thickness comparable to commercially available 2D displays (cell phones, tablets, laptops, etc.). Coherent backlight unit forms uniform, high-collimated and effective illumination of spatial light modulator. Realization of such backlight unit is possible due to holographic optical elements, based on volume gratings, constructing coherent collimated beam to illuminate display plane. Design, recording and measurement of 5.5 inch coherent backlight unit based on two holographic optical elements are presented in this paper.
Analysis method to determine and characterize the mask mean-to-target and uniformity specification
NASA Astrophysics Data System (ADS)
Lee, Sung-Woo; Leunissen, Leonardus H. A.; Van de Kerkhove, Jeroen; Philipsen, Vicky; Jonckheere, Rik; Lee, Suk-Joo; Woo, Sang-Gyun; Cho, Han-Ku; Moon, Joo-Tae
2006-06-01
The specification of the mask mean-to-target (MTT) and uniformity is related to functions as: mask error enhancement factor, dose sensitivity and critical dimension (CD) tolerances. The mask MTT shows a trade-off relationship with the uniformity. Simulations for the mask MTT and uniformity (M-U) are performed for LOGIC devices of 45 and 37 nm nodes according to mask type, illumination condition and illuminator polarization state. CD tolerances and after develop inspection (ADI) target CD's in the simulation are taken from the 2004 ITRS roadmap. The simulation results allow for much smaller tolerances in the uniformity and larger offsets in the MTT than the values as given in the ITRS table. Using the parameters in the ITRS table, the mask uniformity contributes to nearly 95% of total CDU budget for the 45 nm node, and is even larger than the CDU specification of the ITRS for the 37 nm node. We also compared the simulation requirements with the current mask making capabilities. The current mask manufacturing status of the mask uniformity is barely acceptable for the 45 nm node, but requires process improvements towards future nodes. In particular, for the 37 nm node, polarized illumination is necessary to meet the ITRS requirements. The current mask linearity deviates for pitches smaller than 300 nm, which is not acceptable even for the 45 nm node. More efforts on the proximity correction method are required to improve the linearity behavior.
Madrigal-Garcia, Maria Isabel; Rodrigues, Marcos; Shenfield, Alex; Singer, Mervyn; Moreno-Cuesta, Jeronimo
2018-07-01
To identify facial expressions occurring in patients at risk of deterioration in hospital wards. Prospective observational feasibility study. General ward patients in a London Community Hospital, United Kingdom. Thirty-four patients at risk of clinical deterioration. A 5-minute video (25 frames/s; 7,500 images) was recorded, encrypted, and subsequently analyzed for action units by a trained facial action coding system psychologist blinded to outcome. Action units of the upper face, head position, eyes position, lips and jaw position, and lower face were analyzed in conjunction with clinical measures collected within the National Early Warning Score. The most frequently detected action units were action unit 43 (73%) for upper face, action unit 51 (11.7%) for head position, action unit 62 (5.8%) for eyes position, action unit 25 (44.1%) for lips and jaw, and action unit 15 (67.6%) for lower face. The presence of certain combined face displays was increased in patients requiring admission to intensive care, namely, action units 43 + 15 + 25 (face display 1, p < 0.013), action units 43 + 15 + 51/52 (face display 2, p < 0.003), and action units 43 + 15 + 51 + 25 (face display 3, p < 0.002). Having face display 1, face display 2, and face display 3 increased the risk of being admitted to intensive care eight-fold, 18-fold, and as a sure event, respectively. A logistic regression model with face display 1, face display 2, face display 3, and National Early Warning Score as independent covariates described admission to intensive care with an average concordance statistic (C-index) of 0.71 (p = 0.009). Patterned facial expressions can be identified in deteriorating general ward patients. This tool may potentially augment risk prediction of current scoring systems.
Pilot-Configurable Information on a Display Unit
NASA Technical Reports Server (NTRS)
Bell, Charles Frederick (Inventor); Ametsitsi, Julian (Inventor); Che, Tan Nhat (Inventor); Shafaat, Syed Tahir (Inventor)
2017-01-01
A small thin display unit that can be installed in the flight deck for displaying only flight crew-selected tactical information needed for the task at hand. The flight crew can select the tactical information to be displayed by means of any conventional user interface. Whenever the flight crew selects tactical information for processes the request, including periodically retrieving measured current values or computing current values for the requested tactical parameters and returning those current tactical parameter values to the display unit for display.
Positron Survival in Type II Supernovae
1989-05-01
the fewer number of decays depositing energy within the supernova. The rate of this cooling is unknown because it is uncertain whether a pulsar was...details of the radial mixing may yield more precise results but they should not negate my final result. 50 0. LO ’) C u -4S Cu CdU in~~ in0oi 4l cu CV (U...START OF SHELL LO ***.**A***.. for (z=0; z< 14.5; z=z+1.O) ttl= 0; inikdazsity = shell(z]lOI; dshlsum - shejzllhJ/51; fprinzf(point.* Shell numbe
An Electronic Pressure Profile Display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPI) unit which interfaces with a host computer. The host computer collects the pressure data from the DPI unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
An electronic pressure profile display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPT) unit which interfaces with a host computer. The host computer collects the pressure data from the DPT unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
Onboard System Evaluation of Rotors Vibration, Engines (OBSERVE) monitoring System
1992-07-01
consists of a Data Acquisiiton Unit (DAU), Control and Display Unit ( CADU ), Universal Tracking Devices (UTD), Remote Cockpit Display (RCD) and a PC...and Display Unit ( CADU ) - The CADU provides data storage and a graphical user interface neccesary to display both the measured data and diagnostic...information. The CADU has an interface to a Credit Card Memory (CCM) which operates similar to a disk drive, allowing the storage of data and programs. The
Large-screen display industry: market and technology trends for direct view and projection displays
NASA Astrophysics Data System (ADS)
Castellano, Joseph A.; Mentley, David E.
1996-03-01
Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.
1989-02-01
potentials M Modeling or interpretation of SP data T Streaming potential theory TM Telluric current measurement 0 Other 57 REFERENCES Abaza, M. M. I ...470-483. L, T Abaza, M. M. I . 1966. Streaming Current and Streaming Potential Induced by Water Flow Through Porous Media: Ph.D. Thesis, Utah State...IO-- L* - CDU -c) low- -co M~ <__ _ _ i7L - 7 ____~~~~ < K- I ~ 1I1iiij § r~L K mn LKzz{ - i ----_ - t -C 71L- C > 0amp- Daily_ _ Recrd fo Ce uft an
Introduction to the General Campaign Analysis Model (GCAM). Version 3.3
2009-09-01
uncomment and change the label line to label = blackhawk; 14. For the unit to be displayed on the map, it needs a sprite. Uncomment the display style and...sprite lines and change them to display style = SPRITE; and sprite = blackhawk; this associates the unit with the Blackhawk sprite defined in the...infantry #UNIT id=102; label=squad; display style = SPRITE; sprite = infantry; sprite index0 = 0; sprite rotates = FALSE; x0 = 147.82; y0 = -19.26; #END
Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan
2017-08-01
In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.
Wafer hot spot identification through advanced photomask characterization techniques: part 2
NASA Astrophysics Data System (ADS)
Choi, Yohan; Green, Michael; Cho, Young; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike
2017-03-01
Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for mask end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on sub-resolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. To overcome the limitation of 1D metrics, there are numerous on-going industry efforts to better define wafer-predictive metrics through both standard mask metrology and aerial CD methods. Even with these improvements, the industry continues to struggle to define useful correlative metrics that link the mask to final device performance. In part 1 of this work, we utilized advanced mask pattern characterization techniques to extract potential hot spots on the mask and link them, theoretically, to issues with final wafer performance. In this paper, part 2, we complete the work by verifying these techniques at wafer level. The test vehicle (TV) that was used for hot spot detection on the mask in part 1 will be used to expose wafers. The results will be used to verify the mask-level predictions. Finally, wafer performance with predicted and verified mask/wafer condition will be shown as the result of advanced mask characterization. The goal is to maximize mask end user yield through mask-wafer technology harmonization. This harmonization will provide the necessary feedback to determine optimum design, mask specifications, and mask-making conditions for optimal wafer process margin.
Scanner qualification with IntenCD based reticle error correction
NASA Astrophysics Data System (ADS)
Elblinger, Yair; Finders, Jo; Demarteau, Marcel; Wismans, Onno; Minnaert Janssen, Ingrid; Duray, Frank; Ben Yishai, Michael; Mangan, Shmoolik; Cohen, Yaron; Parizat, Ziv; Attal, Shay; Polonsky, Netanel; Englard, Ilan
2010-03-01
Scanner introduction into the fab production environment is a challenging task. An efficient evaluation of scanner performance matrices during factory acceptance test (FAT) and later on during site acceptance test (SAT) is crucial for minimizing the cycle time for pre and post production-start activities. If done effectively, the matrices of base line performance established during the SAT are used as a reference for scanner performance and fleet matching monitoring and maintenance in the fab environment. Key elements which can influence the cycle time of the SAT, FAT and maintenance cycles are the imaging, process and mask characterizations involved with those cycles. Discrete mask measurement techniques are currently in use to create across-mask CDU maps. By subtracting these maps from their final wafer measurement CDU map counterparts, it is possible to assess the real scanner induced printed errors within certain limitations. The current discrete measurement methods are time consuming and some techniques also overlook mask based effects other than line width variations, such as transmission and phase variations, all of which influence the final printed CD variability. Applied Materials Aera2TM mask inspection tool with IntenCDTM technology can scan the mask at high speed, offer full mask coverage and accurate assessment of all masks induced source of errors simultaneously, making it beneficial for scanner qualifications and performance monitoring. In this paper we report on a study that was done to improve a scanner introduction and qualification process using the IntenCD application to map the mask induced CD non uniformity. We will present the results of six scanners in production and discuss the benefits of the new method.
Prospects of DUV OoB suppression techniques in EUV lithography
NASA Astrophysics Data System (ADS)
Park, Chang-Min; Kim, Insung; Kim, Sang-Hyun; Kim, Dong-Wan; Hwang, Myung-Soo; Kang, Soon-Nam; Park, Cheolhong; Kim, Hyun-Woo; Yeo, Jeong-Ho; Kim, Seong-Sue
2014-04-01
Though scaling of source power is still the biggest challenge in EUV lithography (EUVL) technology era, CD and overlay controls for transistor's requirement are also precondition of adopting EUVL in mass production. Two kinds of contributors are identified as risks for CDU and Overlay: Infrared (IR) and deep ultraviolet (DUV) out of band (OOB) radiations from laser produced plasma (LPP) EUV source. IR from plasma generating CO2 laser that causes optics heating and wafer overlay error is well suppressed by introducing grating on collector to diffract IR off the optical axis and is the effect has been confirmed by operation of pre-production tool (NXE3100). EUV and DUV OOB which are reflected from mask black boarder (BB) are root causes of EUV-specific CD error at the boundaries of exposed shots which would result in the problem of CDU out of spec unless sufficiently suppressed. Therefore, control of DUV OOB reflection from the mask BB is one of the key technologies that must be developed prior to EUV mass production. In this paper, quantitative assessment on the advantage and the disadvantage of potential OOB solutions will be discussed. EUV and DUV OOB impacts on wafer CDs are measured from NXE3100 & NXE3300 experiments. Significant increase of DUV OOB impact on CD from NXE3300 compared with NXE3100 is observed. There are three ways of technology being developed to suppress DUV OOB: spectral purity filter (SPF) as a scanner solution, multi-layer etching as a solution on mask, and resist top-coating as a process solution. PROs and CONs of on-scanner, on-mask, and on-resist solution for the mass production of EUV lithography will be discussed.
Nonischemic Priapism in Childhood: A Case Series and Review of Literature.
Hacker, Hans-Walter; Schwoebel, Marcus G; Szavay, Philipp O
2018-06-01
Nonischemic priapism (NIP) in childhood is a very rare affection. In the literature, patients with NIP are described mainly incidental after perineal trauma. Many of them underwent embolization of either internal pudendal artery or bulbocavernosal arteries. We report on six boys between 4 and 13 years of age with NIP, treated at our institution between 2008 and 2014. Color Doppler ultrasound (CDU) was performed in all patients as emergency diagnostic evaluation. Patients were treated conservatively, including bed rest, local cooling, and perineal compression. History, etiological factors, clinical findings, diagnostics, and follow-up are presented. Out of the six patients, only one boy had a history of perineal injury with subsequent arteriocavernosal fistula, revealed in CDU. Five patients were circumcised, and one of them suffered from thalassemia minor, but no other underlying disease or etiological factors could be found. In all patients, normal to high blood flow velocities were detected in the cavernosal arteries. Detumescence started with nonoperative treatment within 24 hours in five boys and in one patient with recurrent priapism after 1 week. All six patients remained painless without evidence for an ischemic priapism. None of them suffered from relapse and further erections were observed during follow-up from 3 to 87 months. In contrast to the literature, five out of six boys developed NIP without a previous perineal trauma. The etiology of idiopathic NIP in childhood remains unclear; however, circumcision may play a role as a conditional factor. One etiological thesis could be the release of the neurotransmitter nitric oxide after stimulation of the corpora cavernosa. Conservative treatment proved to be successful in all six patients. During a median follow-up of 55 months (3-87 months), none of the patients showed signs of erectile dysfunction. Georg Thieme Verlag KG Stuttgart · New York.
Dual-view integral imaging three-dimensional display using polarized glasses.
Wu, Fei; Lv, Guo-Jiao; Deng, Huan; Zhao, Bai-Chuan; Wang, Qiong-Hua
2018-02-20
We propose a dual-view integral imaging (DVII) three-dimensional (3D) display using polarized glasses. The DVII 3D display consists of a display panel, a polarized parallax barrier, a microlens array, and two pairs of polarized glasses. Two kinds of elemental images, which are captured from two different 3D scenes, are alternately arranged on the display panel. The polarized parallax barrier is attached to the display panel and composed of two kinds of units that are also alternately arranged. The polarization directions between adjacent units are perpendicular. The polarization directions of the two pairs of polarized glasses are the same as those of the two kinds of units of the polarized parallax barrier, respectively. The lights emitted from the two kinds of elemental images are modulated by the corresponding polarizer units and microlenses, respectively. Two different 3D images are reconstructed in the viewing zone and separated by using two pairs of polarized glasses. A prototype of the DVII 3D display is developed and two 3D images can be presented simultaneously, verifying the hypothesis.
Current Status Of Ergonomic Standards
NASA Astrophysics Data System (ADS)
Lynch, Gene
1984-05-01
The last five years have seen the development and adoption of new kinds of standards for the display industry. This standardization activity deals with the complex human computer interface. Here the concerns involve health, safety, productivity, and operator well-being. The standards attempt to specify the "proper" use of visual display units. There is a wide range of implications for the display industry - as manufacturers of displays, as employers, and as users of visual display units. In this paper we examine the development of these standards, their impact on the display industry and implications for the future.
EUV via hole pattern fidelity enhancement through novel resist and post-litho plasma treatment
NASA Astrophysics Data System (ADS)
Yaegashi, Hidetami; Koike, Kyohei; Fonseca, Carlos; Yamashita, Fumiko; Kaushik, Kumar; Morikita, Shinya; Ito, Kiyohito; Yoshimura, Shota; Timoshkov, Vadim; Maslow, Mark; Jee, Tae Kwon; Reijnen, Liesbeth; Choi, Peter; Feng, Mu; Spence, Chris; Schoofs, Stijn
2018-03-01
Extreme UV(EUV) technology must be potential solution for sustainable scaling, and its adoption in high volume manufacturing(HVM) is getting realistic more and more. This technology has a wide capability to mitigate various technical problem in Multi-patterning (LELELE) for via hole patterning with 193-i. It induced local pattern fidelity error such like CDU, CER, Pattern placement error. Exactly, EUV must be desirable scaling-driving tool, however, specific technical issue, named RLS (Resolution-LER-Sensitivity) triangle, obvious remaining issue. In this work, we examined hole patterning sensitizing (Lower dose approach) utilizing hole patterning restoration technique named "CD-Healing" as post-Litho. treatment.
Skylab indicators (event timer) (secondary display) (four-digit metabolic display)
NASA Technical Reports Server (NTRS)
Tiberg, W.
1971-01-01
The effort expended in developing the following indicators is summarized: (1) event timer; (2) secondary display; and (3) 4 digit display (metabolic). The mechanical design, vibration analysis, and thermal analysis of all these units are identical, and descriptions pertain to all three units. All problems incurred during the program are discussed along with the recommendations, conclusions, and actions taken to rectify the situations.
Application of holographic elements in displays and planar illuminators
NASA Astrophysics Data System (ADS)
Putilin, Andrew; Gustomiasov, Igor
2007-05-01
Holographic Optical Elements (HOE's) on planar waveguides can be used to design the planar optics for backlit units, color selectors or filters, lenses for virtual reality displays. The several schemes for HOE recording are proposed to obtain planar stereo backlit unit and private eye displays light source. It is shown in the paper that the specific light transformation grating permits to construct efficient backlit units for display holograms and LCD. Several schemes of reflection/transmission backlit units and scattering films based on holographic optical elements are also proposed. The performance of the waveguide HOE can be optimized using the parameters of recording scheme and etching parameters. The schemes of HOE application are discussed and some experimental results are shown.
77 FR 9964 - Certain Video Displays and Products Using and Containing Same
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-828] Certain Video Displays and Products... importation, and the sale within the United States after importation of certain video displays and products... States, the sale for importation, or the sale within the United States after importation of certain video...
A novel shape-changing haptic table-top display
NASA Astrophysics Data System (ADS)
Wang, Jiabin; Zhao, Lu; Liu, Yue; Wang, Yongtian; Cai, Yi
2018-01-01
A shape-changing table-top display with haptic feedback allows its users to perceive 3D visual and texture displays interactively. Since few existing devices are developed as accurate displays with regulatory haptic feedback, a novel attentive and immersive shape changing mechanical interface (SCMI) consisting of image processing unit and transformation unit was proposed in this paper. In order to support a precise 3D table-top display with an offset of less than 2 mm, a custommade mechanism was developed to form precise surface and regulate the feedback force. The proposed image processing unit was capable of extracting texture data from 2D picture for rendering shape-changing surface and realizing 3D modeling. The preliminary evaluation result proved the feasibility of the proposed system.
Li, Lin; Borland, Ron; Fong, Geoffrey T.; Thrasher, James F.; Hammond, David; Cummings, Kenneth M.
2013-01-01
This study examined the impact of point-of-sale (POS) tobacco marketing restrictions in Australia and Canada, in relation to the United Kingdom and the United States where there were no such restrictions during the study period (2006–10). The data came from the International Tobacco Control Four Country Survey, a prospective multi-country cohort survey of adult smokers. In jurisdictions where POS display bans were implemented, smokers’ reported exposure to tobacco marketing declined markedly. From 2006 to 2010, in Canada, the percentages noticing POS tobacco displays declined from 74.1 to 6.1% [adjusted odds ratio (OR) = 0.26, P < 0.001]; and reported exposure to POS tobacco advertising decreased from 40.3 to 14.1% (adjusted OR = 0.61, P < 0.001). Similarly, in Australia, noticing of POS displays decreased from 73.9 to 42.9%. In contrast, exposure to POS marketing in the United States and United Kingdom remained high during this period. In parallel, there were declines in reported exposures to other forms of advertising/promotion in Canada and Australia, but again, not in the United States or United Kingdom. Impulse purchasing of cigarettes was lower in places that enacted POS display bans. These findings indicate that implementing POS tobacco display bans does result in lower exposure to tobacco marketing and less frequent impulse purchasing of cigarettes. PMID:23640986
Li, Lin; Borland, Ron; Fong, Geoffrey T; Thrasher, James F; Hammond, David; Cummings, Kenneth M
2013-10-01
This study examined the impact of point-of-sale (POS) tobacco marketing restrictions in Australia and Canada, in relation to the United Kingdom and the United States where there were no such restrictions during the study period (2006-10). The data came from the International Tobacco Control Four Country Survey, a prospective multi-country cohort survey of adult smokers. In jurisdictions where POS display bans were implemented, smokers' reported exposure to tobacco marketing declined markedly. From 2006 to 2010, in Canada, the percentages noticing POS tobacco displays declined from 74.1 to 6.1% [adjusted odds ratio (OR) = 0.26, P < 0.001]; and reported exposure to POS tobacco advertising decreased from 40.3 to 14.1% (adjusted OR = 0.61, P < 0.001). Similarly, in Australia, noticing of POS displays decreased from 73.9 to 42.9%. In contrast, exposure to POS marketing in the United States and United Kingdom remained high during this period. In parallel, there were declines in reported exposures to other forms of advertising/promotion in Canada and Australia, but again, not in the United States or United Kingdom. Impulse purchasing of cigarettes was lower in places that enacted POS display bans. These findings indicate that implementing POS tobacco display bans does result in lower exposure to tobacco marketing and less frequent impulse purchasing of cigarettes.
Projection display market trends
NASA Astrophysics Data System (ADS)
Mentley, David E.
1997-05-01
The projection display industry is now a multi-billion dollar market comprising an expanding variety of technologies and applications. Growth is being driven by a combination of high volume consumer products and high value business demand. After many years of marginal, but steady performance improvements, essentially all types of projectors have crossed the threshold of acceptability and are now facing accelerated continuing growth. Overall worldwide unit sales of all types of projection displays for all applications will nearly double from 1.6 million units in 1996 to 2.8 million units in 2002. By value at the end user price, the global projector market will grow modestly from 6.3 billion dollars in 1996 to 7.7 billion dollars in 2002. Consumer television will represent the largest share of unit consumption over this time period; in 1996, this application represents 72 percent of the total unit volume. The second major application category for projection displays is the business or presentation projector, representing only 14 percent of the unit shipment total in 1996, but 50 percent of the value.
Mechanical Component Diagnostic System
1991-01-01
Control and Display Unit ( CADU ) executes the system software and controls data acquisition that is carried out by 6 the Data Acquisition Unit (DAU... CADU screen. Displays intended for the CD are also echoed on the CADU in the FDR backup mode. If initialization is successful, clocks are synchronized...and normal MCDS monitoring mode is entered. If there is no display on the CD, the user may manually switch to the backup CD display on the CADU . Hence
Testing Instrument for Flight-Simulator Displays
NASA Technical Reports Server (NTRS)
Haines, Richard F.
1987-01-01
Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.
Interactive graphical computer-aided design system
NASA Technical Reports Server (NTRS)
Edge, T. M.
1975-01-01
System is used for design, layout, and modification of large-scale-integrated (LSI) metal-oxide semiconductor (MOS) arrays. System is structured around small computer which provides real-time support for graphics storage display unit with keyboard, slave display unit, hard copy unit, and graphics tablet for designer/computer interface.
Murray, Anita; Dunlop, Rebecca A; Noad, Michael J; Goldizen, Anne W
2018-02-01
Male humpback whales produce a mating display called "song." Behavioral studies indicate song has inter- and/or intra-sexual functionality, suggesting song may be a multi-message display. Multi-message displays often include stereotypic components that convey group membership for mate attraction and/or male-male interactions, and complex components that convey individual quality for courtship. Humpback whale song contains sounds ("units") arranged into sequences ("phrases"). Repetitions of a specific phrase create a "theme." Within a theme, imperfect phrase repetitions ("phrase variants") create variability among phrases of the same type ("phrase type"). The hypothesis that song contains stereotypic and complex phrase types, structural characteristics consistent with a multi-message display, is investigated using recordings of 17 east Australian males (8:2004, 9:2011). Phrase types are categorized as stereotypic or complex using number of unit types, number of phrase variants, and the proportion of phrases that is unique to an individual versus shared amongst males. Unit types are determined using self-organizing maps. Phrase variants are determined by Levenshtein distances between phrases. Stereotypic phrase types have smaller numbers of unit types and shared phrase variants. Complex phrase types have larger numbers of unit types and unique phrase variants. This study supports the hypothesis that song could be a multi-message display.
A system for the automatic measurement and digital display of systolic and diastolic blood pressures
NASA Technical Reports Server (NTRS)
Schulze, A. E.
1971-01-01
Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement.
Mountain Plains Learning Experience Guide: Marketing. Course: Visual Merchandising.
ERIC Educational Resources Information Center
Preston, T.; Egan, B.
One of thirteen individualized courses included in a marketing curriculum, this course covers the steps to be followed in planning, constructing, and evaluating the effectiveness of merchandise displays. The course is comprised of one unit, General Merchandise Displays. The unit begins with a Unit Learning Experience Guide that gives directions…
Travel guidance system for vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takanabe, K.; Yamamoto, M.; Ito, K.
1987-02-24
A travel guidance system is described for vehicles including: a heading sensor for detecting a direction of movement of a vehicle; a distance sensor for detecting a distance traveled by the vehicle; a map data storage medium preliminarily storing map data; a control unit for receiving a heading signal from the heading sensor and a distance signal from the distance sensor to successively compute a present position of the vehicle and for generating video signals corresponding to display data including map data from the map data storage medium and data of the present position; and a display having first andmore » second display portions and responsive to the video signals from the control unit to display on the first display portion a map and a present portion mark, in which: the map data storage medium comprises means for preliminarily storing administrative division name data and landmark data; and the control unit comprises: landmark display means for: (1) determining a landmark closest to the present position, (2) causing a position of the landmark to be displayed on the map and (3) retrieving a landmark massage concerning the landmark from the storage medium to cause the display to display the landmark message on the second display portion; division name display means for retrieving the name of an administrative division to which the present position belongs from the storage medium and causing the display to display a division name message on the second display portion; and selection means for selectively actuating at least one of the landmark display means and the division name display means.« less
A comparison of advanced overlay technologies
NASA Astrophysics Data System (ADS)
Dasari, Prasad; Smith, Nigel; Goelzer, Gary; Liu, Zhuan; Li, Jie; Tan, Asher; Koh, Chin Hwee
2010-03-01
The extension of optical lithography to 22nm and beyond by Double Patterning Technology is often challenged by CDU and overlay control. With reduced overlay measurement error budgets in the sub-nm range, relying on traditional Total Measurement Uncertainty (TMU) estimates alone is no longer sufficient. In this paper we will report scatterometry overlay measurements data from a set of twelve test wafers, using four different target designs. The TMU of these measurements is under 0.4nm, within the process control requirements for the 22nm node. Comparing the measurement differences between DBO targets (using empirical and model based analysis) and with image-based overlay data indicates the presence of systematic and random measurement errors that exceeds the TMU estimate.
Impact and utilization studies of a PACS display station in an ICU setting
NASA Astrophysics Data System (ADS)
Andriole, Katherine P.; Storto, Maria L.; Gamsu, Gordon; Huang, H. K.
1996-05-01
An assessment of changes in health-care professional behavior as a result of the introduction of a PACS (picture archiving and communication system) display station to an adult medical- surgical intensive care unit (ICU) is investigated via pre- and post-PACs evaluations. ICU display station utilization and the impact on clinical operations are also examined. Parameters measured both pre- and post-PACS ICU display station placement include the number of films per patient day, the number of clinician reviews of a patient's images per day and the percentage of images on which the unit interacts with a radiologist. The elapsed times from the time of exposure to the time of: review by the referring physician, radiologist-unit interaction and clinical action based on image information are also measured. The results of this investigation suggest that the introduction of a PaCS display station in the ICU may reduce the number of exams per patient day, decrease the elapsed time from the time of exposure to the time of review by the unit clinician, and improve the time to clinical action. Note, however, that it does not appear to change the percentage of total images on which the unit interacts with a radiologist.
Payload specialist station study. Part 2: CEI specifications (part 1). [space shuttles
NASA Technical Reports Server (NTRS)
1976-01-01
The performance, design, and verification specifications are established for the multifunction display system (MFDS) to be located at the payload station in the shuttle orbiter aft flight deck. The system provides the display units (with video, alphanumerics, and graphics capabilities), associated with electronic units and the keyboards in support of the payload dedicated controls and the displays concept.
The tongue display unit (TDU) for electrotactile spatiotemporal pattern presentation.
Kaczmarek, K A
2011-12-01
The Tongue Display Unit (TDU) is a 144-channel programmable pulse generator that delivers dc-balanced voltage pulses suitable for electrotactile (electrocutaneous) stimulation of the anterior-dorsal tongue, through a matrix of surface electrodes. This article reviews the theory of operation and a design overview of the TDU, as well as selected applications. These include sensory substitution, tactile information display and neurorehabilitation via induced neuroplasticity.
Monocular display unit for 3D display with correct depth perception
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Hosomi, Takashi
2009-11-01
A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.
ArF scanner performance improvement by using track integrated CD optimization
NASA Astrophysics Data System (ADS)
Huang, Jacky; Yu, Shinn-Sheng; Ke, Chih-Ming; Wu, Timothy; Wang, Yu-Hsi; Gau, Tsai-Sheng; Wang, Dennis; Li, Allen; Yang, Wenge; Kaoru, Araki
2006-03-01
In advanced semiconductor processing, shrinking CD is one of the main objectives when moving to the next generation technology. Improving CD uniformity (CDU) with shrinking CD is one of the biggest challenges. From ArF lithography CD error budget analysis, PEB (post exposure bake) contributes more than 40% CD variations. It turns out that hot plate performance such as CD matching and within-plate temperature control play key roles in litho cell wafer per hour (WPH). Traditionally wired or wireless thermal sensor wafers were used to match and optimize hot plates. However, sensor-to-sensor matching and sensor data quality vs. sensor lifetime or sensor thermal history are still unknown. These concerns make sensor wafers more suitable for coarse mean-temperature adjustment. For precise temperature adjustment, especially within-hot-plate temperature uniformity, using CD instead of sensor wafer temperature is a better and more straightforward metrology to calibrate hot plates. In this study, we evaluated TEL clean track integrated optical CD metrology (IM) combined with TEL CD Optimizer (CDO) software to improve 193-nm resist within-wafer and wafer-to-wafer CD uniformity. Within-wafer CD uniformity is mainly affected by the temperature non-uniformity on the PEB hot plate. Based on CD and PEB sensitivity of photo resists, a physical model has been established to control the CD uniformity through fine-tuning PEB temperature settings. CD data collected by track integrated CD metrology was fed into this model, and the adjustment of PEB setting was calculated and executed through track internal APC system. This auto measurement, auto feed forward, auto calibration and auto adjustment system can reduce the engineer key-in error and improve the hot plate calibration cycle time. And this PEB auto calibration system can easily bring hot-plate-to-hot-plate CD matching to within 0.5nm and within-wafer CDU (3σ) to less than 1.5nm.
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
Improving School Lighting for Video Display Units.
ERIC Educational Resources Information Center
Parker-Jenkins, Marie; Parker-Jenkins, William
1985-01-01
Provides information to identify and implement the key characteristics which contribute to an efficient and comfortable visual display unit (VDU) lighting installation. Areas addressed include VDU lighting requirements, glare, lighting controls, VDU environment, lighting retrofit, optical filters, and lighting recommendations. A checklist to…
A Real-Time Phase Vector Display for EEG Monitoring
NASA Technical Reports Server (NTRS)
Finger, Herbert J.; Anliker, James E.; Rimmer, Tamara
1973-01-01
A real-time, computer-based, phase vector display system has been developed which will output a vector whose phase is equal to the delay between a trigger and the peak of a function which is quasi-coherent with respect to the trigger. The system also contains a sliding averager which enables the operator to average successive trials before calculating the phase vector. Data collection, averaging and display generation are performed on a LINC-8 computer. Output displays appear on several X-Y CRT display units and on a kymograph camera/oscilloscope unit which is used to generate photographs of time-varying phase vectors or contourograms of time-varying averages of input functions.
1993-02-26
CDU *~ IA C, Mt ac ca~ ;-§ = WEBS ~ 2WW -J OWO W W w U .41w 991o 2. Z 9. .J4NUIW fu -W gW atZ W ~~4 uu U~jW * WO W~I WI u at N. 0 0 W W 43I M c MCW4 - IA...t Z --w A -~ 4 -ti LUW C- o.nfl$I-V Pd . - K ~~~s- 5o. In U N U, I.-W cB w o S. -.-Bg a U I N N E % J N*B 0 u ra wz -It- ! - %n .~ *4- De IW. WIx -C
Research development of thermal aberration in 193nm lithography exposure system
NASA Astrophysics Data System (ADS)
Wang, Yueqiang; Liu, Yong
2014-08-01
Lithographic exposure is the key process in the manufacture of the integrated circuit, and the performance of exposure system decides the level of microelectronic manufacture technology. Nowadays, the 193nm ArF immersion exposure tool is widely used by the IC manufacturer. With the uniformity of critical dimension (CDU) and overlay become tighter and the requirement for throughput become higher, the thermal aberration caused by lens material and structure absorbing the laser energy cannot be neglected. In this paper, we introduce the efforts and methods that researcher on thermal aberration and its control. Further, these methods were compared to show their own pros and cons. Finally we investigated the challenges of thermal aberration control for state of the art technologies.
27 CFR 555.122 - Records maintained by licensed importers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... quantity units, such as pounds of explosives, number of detonators, number of display fireworks, etc.). (5) Description (dynamite (dyn), blasting agents (ba), detonators (det), display fireworks (df), etc.) and size... identification. (4) Quantity (applicable quantity units, such as pounds of explosives, number of detonators...
27 CFR 555.122 - Records maintained by licensed importers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... quantity units, such as pounds of explosives, number of detonators, number of display fireworks, etc.). (5) Description (dynamite (dyn), blasting agents (ba), detonators (det), display fireworks (df), etc.) and size... identification. (4) Quantity (applicable quantity units, such as pounds of explosives, number of detonators...
Real-time, high frequency QRS electrocardiograph
NASA Technical Reports Server (NTRS)
Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)
2006-01-01
Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as RAZs. RAZs are displayed as go, no-go signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.
2005-12-14
control of position/orientation of mobile TV cameras. 9 Unit 9 Force interaction system Unit 6 Helmet mounted displays robot like device drive...joints of the master arm (see Unit 1) which joint coordinates are tracked by the virtual manipulator. Unit 6 . Two displays built in the helmet...special device for simulating the tactile- kinaesthetic effect of immersion. When virtual body is a manipulator it comprises: − master arm with 6
Panoramic projection avionics displays
NASA Astrophysics Data System (ADS)
Kalmanash, Michael H.
2003-09-01
Avionics projection displays are entering production in advanced tactical aircraft. Early adopters of this technology in the avionics community used projection displays to replace or upgrade earlier units incorporating direct-view CRT or AMLCD devices. Typical motivation for these upgrades were the alleviation of performance, cost and display device availability concerns. In these systems, the upgraded (projection) displays were one-for-one form / fit replacements for the earlier units. As projection technology has matured, this situation has begun to evolve. The Lockheed-Martin F-35 is the first program in which the cockpit has been specifically designed to take advantage of one of the more unique capabilities of rear projection display technology, namely the ability to replace multiple small screens with a single large conformal viewing surface in the form of a panoramic display. Other programs are expected to follow, since the panoramic formats enable increased mission effectiveness, reduced cost and greater information transfer to the pilot. Some of the advantages and technical challenges associated with panoramic projection displays for avionics applications are described below.
NASA Technical Reports Server (NTRS)
Cheng, Thomas D.; Angelici, Gary L.; Slye, Robert E.; Ma, Matt
1991-01-01
The USDA presently uses labor-intensive photographic interpretation procedures to delineate large geographical areas into manageable size sampling units for the estimation of domestic crop and livestock production. Computer software to automate the boundary delineation procedure, called the computer-assisted stratification and sampling (CASS) system, was developed using a Hewlett Packard color-graphics workstation. The CASS procedures display Thematic Mapper (TM) satellite digital imagery on a graphics display workstation as the backdrop for the onscreen delineation of sampling units. USGS Digital Line Graph (DLG) data for roads and waterways are displayed over the TM imagery to aid in identifying potential sample unit boundaries. Initial analysis conducted with three Missouri counties indicated that CASS was six times faster than the manual techniques in delineating sampling units.
Motion and ranging sensor system for through-the-wall surveillance system
NASA Astrophysics Data System (ADS)
Black, Jeffrey D.
2002-08-01
A portable Through-the-Wall Surveillance System is being developed for law enforcement, counter-terrorism, and military use. The Motion and Ranging Sensor is a radar that operates in a frequency band that allows for surveillance penetration of most non-metallic walls. Changes in the sensed radar returns are analyzed to detect the human motion that would typically be present during a hostage or barricaded suspect scenario. The system consists of a Sensor Unit, a handheld Remote Display Unit, and an optional laptop computer Command Display Console. All units are battery powered and a wireless link provides command and data communication between units. The Sensor Unit is deployed close to the wall or door through which the surveillance is to occur. After deploying the sensor the operator may move freely as required by the scenario. Up to five Sensor Units may be deployed at a single location. A software upgrade to the Command Display Console is also being developed. This software upgrade will combine the motion detected by multiple Sensor Units and determine and track the location of detected motion in two dimensions.
A flexible optically re-writable color liquid crystal display
NASA Astrophysics Data System (ADS)
Zhang, Yihong; Sun, Jiatong; Liu, Yang; Shang, Jianhua; Liu, Hao; Liu, Huashan; Gong, Xiaohui; Chigrinov, Vladimir; Kowk, Hoi Sing
2018-03-01
It is very difficult to make a liquid crystal display (LCD) that is flexible. However, for an optically re-writable LCD (ORWLCD), only the spacers and the substrates need to be flexible because the driving unit and the display unit are separate and there are no electronics in the display part of ORWLCD. In this paper, three flexible-spacer methods are proposed to achieve this goal. A cholesteric liquid crystal colored mirror with a polarizer behind it is used as the colored reflective backboard of an ORWLCD. Polyethersulfone substrates and flexible spacers are used to make the optically re-writable cell insensitive to mechanical force.
2009-12-01
forward-looking infrared FOV field-of-view HDU helmet display unit HMD helmet-mounted display IHADSS Integrated Helmet and Display...monocular Integrated Helmet and Display Sighting System (IHADSS) helmet-mounted display ( HMD ) in the British Army’s Apache AH Mk 1 attack helicopter has any...Integrated Helmet and Display Sighting System, IHADSS, Helmet-mounted display, HMD , Apache helicopter, Visual performance UNCLAS UNCLAS UNCLAS SAR 96
2012-12-01
GPS receiver, the Ashtech ProMark 500; a 3.4-GHz radio modem, the FreeWave 3400-SMR; a display unit, the Magellan MobileMapper CX; a 12-V battery pack...Figure 8. Bottom view of the ProMark 500. 3.1 Survey Unit RTK GPS Setup The following are the procedures for setting up...the RTK GPS Survey Unit: 1. Connect the radio modem to the ProMark 500 with serial cable #7 and #8. Display Screen Scroll Button Power LED Log
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... Certain Display Devices, Including Digital Televisions and Monitors II, DN 2787; the Commission is... importation of certain display devices, including digital televisions and monitors II. The complaint names as... in the United States economy, the production of like or directly competitive articles in the United...
Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection
NASA Technical Reports Server (NTRS)
Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)
2009-01-01
Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.
Driving imaging and overlay performance to the limits with advanced lithography optimization
NASA Astrophysics Data System (ADS)
Mulkens, Jan; Finders, Jo; van der Laan, Hans; Hinnen, Paul; Kubis, Michael; Beems, Marcel
2012-03-01
Immersion lithography is being extended to 22-nm and even below. Next to generic scanner system improvements, application specific solutions are needed to follow the requirements for CD control and overlay. Starting from the performance budgets, this paper discusses how to improve (in volume manufacturing environment) CDU towards 1-nm and overlay towards 3-nm. The improvements are based on deploying the actuator capabilities of the immersion scanner. The latest generation immersion scanners have extended the correction capabilities for overlay and imaging, offering freeform adjustments of lens, illuminator and wafer grid. In order to determine the needed adjustments the recipe generation per user application is based on a combination wafer metrology data and computational lithography methods. For overlay, focus and CD metrology we use an angle resolved optical scatterometer.
Pilot factors guidelines for the operational inspection of navigation systems
NASA Technical Reports Server (NTRS)
Sadler, J. F.; Boucek, G. P.
1988-01-01
A computerized human engineered inspection technique is developed for use by FAA inspectors in evaluating the pilot factors aspects of aircraft navigation systems. The short title for this project is Nav Handbook. A menu-driven checklist, computer program and data base (Human Factors Design Criteria) were developed and merged to form a self-contained, portable, human factors inspection checklist tool for use in a laboratory or field setting. The automated checklist is tailored for general aviation navigation systems and can be expanded for use with other aircraft systems, transports or military aircraft. The Nav Handbook inspection concept was demonstrated using a lap-top computer and an Omega/VLF CDU. The program generates standardized inspection reports. Automated checklists for LORAN/C and R NAV were also developed. A Nav Handbook User's Guide is included.
1982-09-01
CA- 2: < C . V D CD LU CD C - U .- LU CA V) u 0.. VA 0 0.. L:U 0. - i LU u A C.D C u- C) LU wU 0.. 00 LUV ) - - ~ z C ci, ci, CA L L >- L" CDU CA 7: U...1 . o i s =Z.~ Irk: c 43- L a a I -cm I -ty Pa ea -~ c.C a I.f oIl sa a 1 !& amv 0-4 P 1- inj 0!6I o. i4. I e S!& I a DIVI ~ a Ip- w o cr 1, -40 e a...Data Entered) ___________________________________________READ INSTRUCTIONS REPORT DOCUMENTATION PAGE BEFORE COMPLETING FORM I . REPORT NUMBER 12. GOVT
Dennis, M; Sandercock, P; Reid, J; Graham, C; Forbes, J; Murray, G
2013-08-10
Venous thromboembolism is a common, potentially avoidable cause of death and morbidity in patients in hospital, including those with stroke. In surgical patients, intermittent pneumatic compression (IPC) reduces the risk of deep vein thrombosis (DVT), but no reliable evidence exists about its effectiveness in patients who have had a stroke. We assessed the effectiveness of IPC to reduce the risk of DVT in patients who have had a stroke. The CLOTS 3 trial is a multicentre parallel group randomised trial assessing IPC in immobile patients (ie, who cannot walk to the toilet without the help of another person) with acute stroke. We enrolled patients from day 0 to day 3 of admission and allocated them via a central randomisation system (ratio 1:1) to receive either IPC or no IPC. A technician who was masked to treatment allocation did a compression duplex ultrasound (CDU) of both legs at 7-10 days and, wherever practical, at 25-30 days after enrolment. Caregivers and patients were not masked to treatment assignment. Patients were followed up for 6 months to determine survival and later symptomatic venous thromboembolism. The primary outcome was a DVT in the proximal veins detected on a screening CDU or any symptomatic DVT in the proximal veins, confirmed on imaging, within 30 days of randomisation. Patients were analysed according to their treatment allocation. ISRCTN93529999. Between Dec 8, 2008, and Sept 6, 2012, 2876 patients were enrolled in 94 centres in the UK. The included patients were broadly representative of immobile stroke patients admitted to hospital and had a median age of 76 years (IQR 67-84). The primary outcome occurred in 122 (8·5%) of 1438 patients allocated IPC and 174 (12·1%) of 1438 patients allocated no IPC; an absolute reduction in risk of 3·6% (95% CI 1·4-5·8). Excluding the 323 patients who died before any primary outcome and 41 without any screening CDU, the adjusted OR for the comparison of 122 of 1267 patients vs 174 of 1245 patients was 0·65 (95% CI 0·51-0·84; p=0·001). Deaths in the treatment period occurred in 156 (11%) patients allocated IPC and 189 (13%) patients allocated no IPC died within the 30 days of treatment period (p=0·057); skin breaks on the legs were reported in 44 (3%) patients allocated IPC and in 20 (1%) patients allocated no IPC (p=0·002); falls with injury were reported in 33 (2%) patients in the IPC group and in 24 (2%) patients in the no-IPC group (p=0·221). IPC is an effective method of reducing the risk of DVT and possibly improving survival in a wide variety of patients who are immobile after stroke. National Institute of Health Research (NIHR) Health Technology Assessment (HTA) programme, UK; Chief Scientist Office of Scottish Government; Covidien (MA, USA). Copyright © 2013 The Authors. Open Access article distributed under the terms of CC BY-NC-ND. Published by Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... Effects Devices and Image Display Devices and Components and Products Containing Same; Notice of... United States after importation of certain motion-sensitive sound effects devices and image display... devices and image display devices and components and products containing same that infringe one or more of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-20
... INTERNATIONAL TRADE COMMISSION [DN 2871] Certain Video Displays and Products Using and Containing... Trade Commission has received a complaint entitled In Re Certain Video Displays and Products Using and... for importation, and the sale within the United States after importation of certain video displays and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-27
... Frames and Image Display Devices and Components Thereof; Notice of Institution of Investigation... United States after importation of certain digital photo frames and image display devices and components... certain digital photo frames and image display devices and components thereof that infringe one or more of...
NASA Astrophysics Data System (ADS)
Yang, Le; Sang, Xinzhu; Yu, Xunbo; Liu, Boyang; Liu, Li; Yang, Shenwu; Yan, Binbin; Du, Jingyan; Gao, Chao
2018-05-01
A 54-inch horizontal-parallax only light-field display based on the light-emitting diode (LED) panel and the micro-pinhole unit array (MPUA) is demonstrated. Normally, the perceived 3D effect of the three-dimensional (3D) display with smooth motion parallax and abundant light-field information can be enhanced with increasing the density of viewpoints. However, the density of viewpoints is inversely proportional to the spatial display resolution for the conventional integral imaging. Here, a special MPUA is designed and fabricated, and the displayed 3D scene constructed by the proposed horizontal light-field display is presented. Compared with the conventional integral imaging, both the density of horizontal viewpoints and the spatial display resolution are significantly improved. In the experiment, A 54-inch horizontal light-field display with 42.8° viewing angle based on the LED panel with the resolution of 1280 × 720 and the MPUA is realized, which can provide natural 3D visual effect to observers with high quality.
Detached rock evaluation device
Hanson, David R.
1986-01-01
A rock detachment evaluation device (10) having an energy transducer unit 1) for sensing vibrations imparted to a subject rock (172) for converting the sensed vibrations into electrical signals, a low band pass filter unit (12) for receiving the electrical signal and transmitting only a low frequency segment thereof, a high band pass filter unit (13) for receiving the electrical signals and for transmitting only a high frequency segment thereof, a comparison unit (14) for receiving the low frequency and high frequency signals and for determining the difference in power between the signals, and a display unit (16) for displaying indicia of the difference, which provides a quantitative measure of rock detachment.
48 CFR 52.203-14 - Display of Hotline Poster(s).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Display of Hotline Poster... Clauses 52.203-14 Display of Hotline Poster(s). As prescribed in 3.1004(b), insert the following clause: Display of Hotline Poster(s) (DEC 2007) (a) Definition. United States, as used in this clause, means the...
48 CFR 52.203-14 - Display of Hotline Poster(s).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Display of Hotline Poster... Clauses 52.203-14 Display of Hotline Poster(s). As prescribed in 3.1004(b), insert the following clause: Display of Hotline Poster(s) (DEC 2007) (a) Definition. United States, as used in this clause, means the...
48 CFR 52.203-14 - Display of Hotline Poster(s).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 2 2011-10-01 2011-10-01 false Display of Hotline Poster... Clauses 52.203-14 Display of Hotline Poster(s). As prescribed in 3.1004(b), insert the following clause: Display of Hotline Poster(s) (DEC 2007) (a) Definition. United States, as used in this clause, means the...
48 CFR 52.203-14 - Display of Hotline Poster(s).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 2 2014-10-01 2014-10-01 false Display of Hotline Poster... Clauses 52.203-14 Display of Hotline Poster(s). As prescribed in 3.1004(b), insert the following clause: Display of Hotline Poster(s) (DEC 2007) (a) Definition. United States, as used in this clause, means the...
48 CFR 52.203-14 - Display of Hotline Poster(s).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 2 2012-10-01 2012-10-01 false Display of Hotline Poster... Clauses 52.203-14 Display of Hotline Poster(s). As prescribed in 3.1004(b), insert the following clause: Display of Hotline Poster(s) (DEC 2007) (a) Definition. United States, as used in this clause, means the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... Image Display Devices and Components Thereof; Issuance of a Limited Exclusion Order and Cease and Desist... within the United States after importation of certain digital photo frames and image display devices and...: (1) The unlicensed entry of digital photo frames and image display devices and components thereof...
NASA Technical Reports Server (NTRS)
Ferris, Alice T.; White, William C.
1988-01-01
Balance dynamic display unit (BDDU) is compact system conditioning six dynamic analog signals so they are monitored simultaneously in real time on single-trace oscilloscope. Typical BDDU oscilloscope display in scan mode shows each channel occupying one-sixth of total trace. System features two display modes usable with conventional, single-channel oscilloscope: multiplexed six-channel "bar-graph" format and single-channel display. Two-stage visual and audible limit alarm provided for each channel.
Co-optimization of lithographic and patterning processes for improved EPE performance
NASA Astrophysics Data System (ADS)
Maslow, Mark J.; Timoshkov, Vadim; Kiers, Ton; Jee, Tae Kwon; de Loijer, Peter; Morikita, Shinya; Demand, Marc; Metz, Andrew W.; Okada, Soichiro; Kumar, Kaushik A.; Biesemans, Serge; Yaegashi, Hidetami; Di Lorenzo, Paolo; Bekaert, Joost P.; Mao, Ming; Beral, Christophe; Larivière, Stephane
2017-03-01
Complimentary lithography is already being used for advanced logic patterns. The tight pitches for 1D Metal layers are expected to be created using spacer based multiple patterning ArF-i exposures and the more complex cut/block patterns are made using EUV exposures. At the same time, control requirements of CDU, pattern shift and pitch-walk are approaching sub-nanometer levels to meet edge placement error (EPE) requirements. Local variability, such as Line Edge Roughness (LER), Local CDU, and Local Placement Error (LPE), are dominant factors in the total Edge Placement error budget. In the lithography process, improving the imaging contrast when printing the core pattern has been shown to improve the local variability. In the etch process, it has been shown that the fusion of atomic level etching and deposition can also improve these local variations. Co-optimization of lithography and etch processing is expected to further improve the performance over individual optimizations alone. To meet the scaling requirements and keep process complexity to a minimum, EUV is increasingly seen as the platform for delivering the exposures for both the grating and the cut/block patterns beyond N7. In this work, we evaluated the overlay and pattern fidelity of an EUV block printed in a negative tone resist on an ArF-i SAQP grating. High-order Overlay modeling and corrections during the exposure can reduce overlay error after development, a significant component of the total EPE. During etch, additional degrees of freedom are available to improve the pattern placement error in single layer processes. Process control of advanced pitch nanoscale-multi-patterning techniques as described above is exceedingly complicated in a high volume manufacturing environment. Incorporating potential patterning optimizations into both design and HVM controls for the lithography process is expected to bring a combined benefit over individual optimizations. In this work we will show the EPE performance improvement for a 32nm pitch SAQP + block patterned Metal 2 layer by cooptimizing the lithography and etch processes. Recommendations for further improvements and alternative processes will be given.
Dubbelman, Yvette D; Wildhagen, Mark F; Dohle, Gert R
2008-09-01
Sexual dysfunction is common after surgery for prostate cancer. The aetiology of changes in sexual potency after radical prostatectomy is probably multifactorial, including neurogenic, vascular and psychosexual factors. A prospective study was designed to investigate haemodynamic and psychosexual changes before and after radical retropubic prostatectomy (RRP) for organ-confined prostate cancer. Penile haemodynamic evaluation and an assessment of sexual excitement were performed preoperatively and 3 months after RRP by colour Doppler ultrasonography (CDU) with visual erotic stimulation combined with a single intracavernous injection of a mixture of papaverine/phentolamine. Questionnaires on sexual function [International Index of Erectile Function (IIEF)], general health and quality of life were sent to the patients preoperative, 3 months and 5 years after operation. Forty-eight men participated in the study. Mean age was 62.6 years (range 55-69). CDU did not show any significant reduction in mean peak systolic flow velocity and mean resistance index. From the men who preoperatively had normal arterial inflow 18% developed arteriogenic insufficiency. Some form of veno-occlusive insufficiency and low resistance indices were already present in the majority of normal potent men preoperatively. Surgical technique did not influence penile arterial blood flow after the operation. Three months and 5 years postoperatively, there was a highly significant reduction in erectile function, intercourse satisfaction, overall satisfaction, orgasmic function and sexual desire. However, with respect to the outcome at 3 months there was a significant improvement of orgasmic function 5 years after operation, especially after a bilateral nerve sparing procedure. Erections sufficient for vaginal penetration (questions 3 and 4 of the IIEF, score >or=8) improved from 2% to 11% 3 months and 5 years after RRP respectively. Total IIEF score was significantly better after a bilateral nerve-sparing procedure compared with non-nerve sparing. No structural vascular changes were observed 3 months after operation. Vascular factors appear to be less important in the aetiology of ED after RRP. There seems to be a trend of a better improvement of sexual function over time, especially orgasmic function, in patients with bilateral nerve-sparing surgery.
NASA Astrophysics Data System (ADS)
Bartlett, Christopher T.
2000-08-01
The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.
ERIC Educational Resources Information Center
Bauer, R. D.; Schaadt, M. S.
1984-01-01
Calfiornia State University (Long Beach) purchased a motor home and converted it into a mobile marine science display unit, outfitting it with built-in display racks inside and an awning to provide shelter displays suited to outdoor use. School activities and programs using the mobile museum are described. (JN)
Autotransporter-based cell surface display in Gram-negative bacteria.
Nicolay, Toon; Vanderleyden, Jos; Spaepen, Stijn
2015-02-01
Cell surface display of proteins can be used for several biotechnological applications such as the screening of protein libraries, whole cell biocatalysis and live vaccine development. Amongst all secretion systems and surface appendages of Gram-negative bacteria, the autotransporter secretion pathway holds great potential for surface display because of its modular structure and apparent simplicity. Autotransporters are polypeptides made up of an N-terminal signal peptide, a secreted or surface-displayed passenger domain and a membrane-anchored C-terminal translocation unit. Genetic replacement of the passenger domain allows for the surface display of heterologous passengers. An autotransporter-based surface expression module essentially consists of an application-dependent promoter system, a signal peptide, a passenger domain of interest and the autotransporter translocation unit. The passenger domain needs to be compatible with surface translocation although till now no general rules have been determined to test this compatibility. The autotransporter technology for surface display of heterologous passenger domains is critically discussed for various applications.
The Effects of a Point-of-Purchase Display on Relative Sales: An In-Store Experimental Evaluation
ERIC Educational Resources Information Center
Sigurdsson, Valdimar; Engilbertsson, Halldor; Foxall, Gordon
2010-01-01
An in-store experiment was performed to investigate the effects of a point-of-purchase display on unit sales of dishwashing liquid. The experimental conditions consisted of periodically placing two copies of the same display in convenience stores and supermarkets. The results were unanticipated; point-of-purchase displays did not change relative…
Advanced and tendencies in the development of display technologies
NASA Astrophysics Data System (ADS)
Kompanets, I. N.
2006-06-01
Advances and key display applications are discussed. Computer, compact mobile, TV and collective large screen displays are mentioned. Flat panel displays step on CRT devices to leave them behind in 2007. Materials, active matricies and applications of bright radiative field emission and organic LED displays are developing successively and pressing other technologies to be used in photo-cameras, cellular phones, auto-cars and avionics. Progress in flexible screens can substantially extend the display design and application soon. 3D display systems are under intensive development, and laser is an important unit in some vaiants of holographic and volumetric 3D displays. Value forecast of different display markets is presented.
Communicating with residential electrical devices via a vehicle telematics unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Rebecca C.; Pebbles, Paul H.
A method of communicating with residential electrical devices using a vehicle telematics unit includes receiving information identifying a residential electrical device to control; displaying in a vehicle one or more controlled features of the identified residential electrical device; receiving from a vehicle occupant a selection of the displayed controlled features of the residential electrical device; sending an instruction from the vehicle telematics unit to the residential electrical device via a wireless carrier system in response to the received selection; and controlling the residential electrical device using the sent instruction.
DSA patterning options for logics and memory applications
NASA Astrophysics Data System (ADS)
Liu, Chi-Chun; Franke, Elliott; Mignot, Yann; LeFevre, Scott; Sieg, Stuart; Chi, Cheng; Meli, Luciana; Parnell, Doni; Schmidt, Kristin; Sanchez, Martha; Singh, Lovejeet; Furukawa, Tsuyoshi; Seshadri, Indira; De Silva, Ekmini Anuja; Tsai, Hsinyu; Lai, Kafai; Truong, Hoa; Farrell, Richard; Bruce, Robert; Somervell, Mark; Sanders, Daniel; Felix, Nelson; Arnold, John; Hetzer, David; Ko, Akiteru; Metz, Andrew; Colburn, Matthew; Corliss, Daniel
2017-03-01
The progress of three potential DSA applications, i.e. fin formation, via shrink, and pillars, were reviewed in this paper. For fin application, in addition to pattern quality, other important considerations such as customization and design flexibility were discussed. An electrical viachain study verified the DSA rectification effect on CD distribution by showing a tighter current distribution compared to that derived from the guiding pattern direct transfer without using DSA. Finally, a structural demonstration of pillar formation highlights the importance of pattern transfer in retaining both the CD and local CDU improvement from DSA. The learning from these three case studies can provide perspectives that may not have been considered thoroughly in the past. By including more important elements during DSA process development, the DSA maturity can be further advanced and move DSA closer to HVM adoption.
Feasibility study of utilizing ultraportable projectors for endoscopic video display (with videos).
Tang, Shou-Jiang; Fehring, Amanda; Mclemore, Mac; Griswold, Michael; Wang, Wanmei; Paine, Elizabeth R; Wu, Ruonan; To, Filip
2014-10-01
Modern endoscopy requires video display. Recent miniaturized, ultraportable projectors are affordable, durable, and offer quality image display. Explore feasibility of using ultraportable projectors in endoscopy. Prospective bench-top comparison; clinical feasibility study. Masked comparison study of images displayed via 2 Samsung ultraportable light-emitting diode projectors (pocket-sized SP-HO3; pico projector SP-P410M) and 1 Microvision Showwx-II Laser pico projector. BENCH-TOP FEASIBILITY STUDY: Prerecorded endoscopic video was streamed via computer. CLINICAL COMPARISON STUDY: Live high-definition endoscopy video was simultaneously displayed through each processor onto a standard liquid crystal display monitor and projected onto a portable, pull-down projection screen. Endoscopists, endoscopy nurses, and technicians rated video images; ratings were analyzed by linear mixed-effects regression models with random intercepts. All projectors were easy to set up, adjust, focus, and operate, with no real-time lapse for any. Bench-top study outcomes: Samsung pico preferred to Laser pico, overall rating 1.5 units higher (95% confidence interval [CI] = 0.7-2.4), P < .001; Samsung pocket preferred to Laser pico, 3.3 units higher (95% CI = 2.4-4.1), P < .001; Samsung pocket preferred to Samsung pico, 1.7 units higher (95% CI = 0.9-2.5), P < .001. The clinical comparison study confirmed the Samsung pocket projector as best, with a higher overall rating of 2.3 units (95% CI = 1.6-3.0), P < .001, than Samsung pico. Low brightness currently limits pico projector use in clinical endoscopy. The pocket projector, with higher brightness levels (170 lumens), is clinically useful. Continued improvements to ultraportable projectors will supply a needed niche in endoscopy through portability, reduced cost, and equal or better image quality. © The Author(s) 2013.
Burst-by-burst laser frequency monitor
NASA Technical Reports Server (NTRS)
Esproles, Carlos (Inventor)
1994-01-01
The invention is a system for real-time frequency monitoring and display of an RF burst where the burst frequency is analyzed and displayed on a burst-by-burst basis in order to allow for frequency control. Although the invention was made for monitoring the laser frequency of a LIDAR system, it has other applications where realtime monitoring is required. The novelty of the invention resides in the use of a counter that is reset at the beginning of each unit time of monitoring and then gated for a unit of time. The invention also has an LED bar graph for displaying the measure of frequency at the end of each unit time in either a bar length mode or a moving dot mode. In the latter mode, the operator makes necessary adjustments to maintain the dot at the center of the bar graph.
Development and Evaluation of Sterographic Display for Lung Cancer Screening
2008-12-01
burden. Application of GPUs – With the evolution of commodity graphics processing units (GPUs) for accelerating games on personal computers, over the...units, which are designed for rendering computer games , are readily available and can be programmed to perform the kinds of real-time calculations...575-581, 1994. 12. Anderson CM, Saloner D, Tsuruda JS, Shapeero LG, Lee RE. "Artifacts in maximun-intensity-projection display of MR angiograms
Advanced Extravehicular Mobility Unit Informatics Software Design
NASA Technical Reports Server (NTRS)
Wright, Theodore
2014-01-01
This is a description of the software design for the 2013 edition of the Advanced Extravehicular Mobility Unit (AEMU) Informatics computer assembly. The Informatics system is an optional part of the space suit assembly. It adds a graphical interface for displaying suit status, timelines, procedures, and caution and warning information. In the future it will display maps with GPS position data, and video and still images captured by the astronaut.
Color flat panel display for the Bradley Fighting Vehicle
NASA Astrophysics Data System (ADS)
Prince, J. Colin; Martin, A. J.
1996-05-01
The modernization program for the Bradley Fighting Vehicle, M2 A3, represents the first deployment of an active matrix liquid crystal display, AMLCD, in a military ground vehicle. In many respects the selection of AMLCD was determined according to the familiar metrics which have resulted in AMLCD being broadly selected for modern air vehicle installations. In fact, there is considerable similarities between the Bradley AMLCD and its recent forbearers in the avionic industry. In the Bradley, the AMLCD unit is referred to as a color flat panel display, CFPD and the features of this unit, as well as its environment and utilization are described in this paper.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-836] Certain Consumer Electronics and Display... electronics and display devices and products containing same by reason of infringement of certain claims of U... importation, or the sale within the United States after importation of certain consumer electronics and...
37 CFR 1.419 - Display of currently valid control number under the Paperwork Reduction Act.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Display of currently valid... UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES International Processing Provisions General Information § 1.419 Display of currently valid control...
Research on Chinese characters display of airborne MFD based on GL studio
NASA Astrophysics Data System (ADS)
Wang, Zhile; Dong, Junyu; Hu, Wenting; Cui, Yipeng
2018-04-01
GL Studio cannot display Chinese characters during developing the airborne MFD, this paper propose a method of establishing a Chinese character font with GB2312 encoding, establish the font table and the display unit of Chinese characters based on GL Studio. Abstract the storage and display data model of Chinese characters, parse the GB encoding of the corresponding Chinese characters that MFD received, find the coordinates of the Chinese characters in the font table, establish the dynamic control model and the dynamic display model of Chinese characters based on the display unit of Chinese characters. In GL Studio and VC ++.NET environment, this model has been successfully applied to develop the airborne MFD in a variety of mission simulators. This method has successfully solved the problem that GL Studio software cannot develop MFD software of Chinese domestic aircraft and can also be used for other professional airborne MFD development tools such as IDATA. It has been proved by experiments that this is a fast effective scalable and reconfigurable method of developing both actual equipment and simulators.
NASA Astrophysics Data System (ADS)
Figl, Michael; Birkfellner, Wolfgang; Watzinger, Franz; Wanschitz, Felix; Hummel, Johann; Hanel, Rudolf A.; Ewers, Rolf; Bergmann, Helmar
2002-05-01
Two main concepts of Head Mounted Displays (HMD) for augmented reality (AR) visualization exist, the optical and video-see through type. Several research groups have pursued both approaches for utilizing HMDs for computer aided surgery. While the hardware requirements for a video see through HMD to achieve acceptable time delay and frame rate seem to be enormous the clinical acceptance of such a device is doubtful from a practical point of view. Starting from previous work in displaying additional computer-generated graphics in operating microscopes, we have adapted a miniature head mounted operating microscope for AR by integrating two very small computer displays. To calibrate the projection parameters of this so called Varioscope AR we have used Tsai's Algorithm for camera calibration. Connection to a surgical navigation system was performed by defining an open interface to the control unit of the Varioscope AR. The control unit consists of a standard PC with a dual head graphics adapter to render and display the desired augmentation of the scene. We connected this control unit to a computer aided surgery (CAS) system by the TCP/IP interface. In this paper we present the control unit for the HMD and its software design. We tested two different optical tracking systems, the Flashpoint (Image Guided Technologies, Boulder, CO), which provided about 10 frames per second, and the Polaris (Northern Digital, Ontario, Canada) which provided at least 30 frames per second, both with a time delay of one frame.
A knowledge based application of the extended aircraft interrogation and display system
NASA Technical Reports Server (NTRS)
Glover, Richard D.; Larson, Richard R.
1991-01-01
A family of multiple-processor ground support test equipment was used to test digital flight-control systems on high-performance research aircraft. A unit recently built for the F-18 high alpha research vehicle project is the latest model in a series called the extended aircraft interrogation and display system. The primary feature emphasized monitors the aircraft MIL-STD-1553B data buses and provides real-time engineering units displays of flight-control parameters. A customized software package was developed to provide real-time data interpretation based on rules embodied in a highly structured knowledge database. The configuration of this extended aircraft interrogation and display system is briefly described, and the evolution of the rule based package and its application to failure modes and effects testing on the F-18 high alpha research vehicle is discussed.
Shen, Xin; Javidi, Bahram
2018-03-01
We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.
Battle Group Asset Management Decision Support System.
1984-03-01
3.141 Terminal Display - Battle Group Missile Sys . 202 3.142 Battle Group Gun Systems . . . . . . . . . . . 204 3.143 Force missile and Gun Systems...with the sys -.6e, and/or the battle group has nct, as yet, been 61 * (MAIN MENU CC¢TI.) * SENSCR --- GRAPHICALLY DISPLAY UNIT/FORCE SENSCR *COVERAGE...BUILD A DATABASE OF THE CAPABILITIES OF THE UNITS IN YOUR BATTLE GROUP. THESE I CAPAEILITIES WILL INCLUDE ALL SENSOR AND WEAPONS SYS - TEES CNBCARD, AS
A superior architecture of brightness enhancement for display backlighting
NASA Astrophysics Data System (ADS)
Dross, Oliver; Parkyn, William A.; Chaves, Julio; Falicoff, Waqidi; Miñano, Juan Carlos; Benitez, Pablo; Alvarez, Roberto
2006-08-01
Brightness enhancement of backlighting for displays is typically achieved via crossed micro prismatic films that are introduced between a backlight unit and a transmissive (LCD) display. Prismatic films let pass light only into a restricted angular range, while, in conjunction with other reflective elements below the backlight, all other light is recycled within the backlight unit, thereby increasing the backlight luminance. This design offers no free parameters to influence the resulting light distribution and suffers from insufficient stray light control. A novel strategy of light recycling is introduced, using a microlens array in conjunction with a hole array in a reflective surface, that can provide higher luminance, superior stray light control, and can be designed to meet almost any desired emission pattern. Similar strategies can be applied to mix light from different colored LEDs being mounted upside down to shine into a backlight unit.
A portable device for rapid nondestructive detection of fresh meat quality
NASA Astrophysics Data System (ADS)
Lin, Wan; Peng, Yankun
2014-05-01
Quality attributes of fresh meat influence nutritional value and consumers' purchasing power. In order to meet the demand of inspection department for portable device, a rapid and nondestructive detection device for fresh meat quality based on ARM (Advanced RISC Machines) processor and VIS/NIR technology was designed. Working principal, hardware composition, software system and functional test were introduced. Hardware system consisted of ARM processing unit, light source unit, detection probe unit, spectral data acquisition unit, LCD (Liquid Crystal Display) touch screen display unit, power unit and the cooling unit. Linux operating system and quality parameters acquisition processing application were designed. This system has realized collecting spectral signal, storing, displaying and processing as integration with the weight of 3.5 kg. 40 pieces of beef were used in experiment to validate the stability and reliability. The results indicated that prediction model developed using PLSR method using SNV as pre-processing method had good performance, with the correlation coefficient of 0.90 and root mean square error of 1.56 for validation set for L*, 0.95 and 1.74 for a*,0.94 and 0.59 for b*, 0.88 and 0.13 for pH, 0.79 and 12.46 for tenderness, 0.89 and 0.91 for water content, respectively. The experimental result shows that this device can be a useful tool for detecting quality of meat.
Three-terminal RGB full-color OLED pixels for ultrahigh density displays.
Fröbel, Markus; Fries, Felix; Schwab, Tobias; Lenk, Simone; Leo, Karl; Gather, Malte C; Reineke, Sebastian
2018-06-26
In recent years, the organic light-emitting diode (OLED) technology has been a rapidly evolving field of research, successfully making the transition to commercial applications such as mobile phones and other small portable devices. OLEDs provide efficient generation of light, excellent color quality, and allow for innovative display designs, e.g., curved shapes, mechanically flexible and/or transparent devices. Especially their self emissive nature is a highly desirable feature for display applications. In this work, we demonstrate an approach for full-color OLED pixels that are fabricated by vertical stacking of a red-, green-, and blue-emitting unit. Each unit can be addressed separately which allows for efficient generation of every color that is accessible by superpositioning the spectra of the individual emission units. Here, we use a combination of time division multiplexing and pulse width modulation to achieve efficient color mixing. The presented device design requires only three independently addressable electrodes, simplifying both fabrication and electrical driving. The device is built in a top-emission geometry, which is highly desirable for display fabrication as the pixel can be directly deposited onto back-plane electronics. Despite the top-emission design and the application of three silver layers within the device, there is only a minor color shift even for large viewing angles. The color space spanned by the three emission sub-units exceeds the sRGB space, providing more saturated green/yellow/red colors. Furthermore, the electrical performance of each individual unit is on par with standard single emission unit OLEDs, showing very low leakage currents and achieving brightness levels above 1000 cd/m 2 at moderate voltages of around 3-4 V.
Right-Wing Politicians Prefer the Emotional Left
Thomas, Nicole A.; Loetscher, Tobias; Clode, Danielle; Nicholls, Michael E. R.
2012-01-01
Physiological research suggests that social attitudes, such as political beliefs, may be partly hard-wired in the brain. Conservatives have heightened sensitivity for detecting emotional faces and use emotion more effectively when campaigning. As the left face displays emotion more prominently, we examined 1538 official photographs of conservative and liberal politicians from Australia, Canada, the United Kingdom and the United States for an asymmetry in posing. Across nations, conservatives were more likely than liberals to display the left cheek. In contrast, liberals were more likely to face forward than were conservatives. Emotion is important in political campaigning and as portraits influence voting decisions, conservative politicians may intuitively display the left face to convey emotion to voters. PMID:22567166
NASA Astrophysics Data System (ADS)
Bézard, P.; Chevalier, X.; Legrain, A.; Navarro, C.; Nicolet, C.; Fleury, G.; Cayrefourcq, I.; Tiron, R.; Zelsmann, M.
2018-03-01
In this work, we present our recent achievements on the integration and transfer etching of a novel silicon-containing high-χ block copolymer for lines/spaces applications. Developed carbo-silane BCPs are synthesized under industrial conditions and present periodicities as low as 14 nm. A full directed self-assembly by graphoepitaxy process is shown using standard photolithography stacks and all processes are performed on 300 mm wafer compatible tools. Specific plasma processes are developed to isolate perpendicular lamellae and sub-12 nm features are finally transferred into silicon substrates. The quality of the final BCP hard mask (CDU, LWR, LER) are also investigated. Finally, thanks to the development of dedicated neutral layers and top-coats allowing perpendicular orientations, it was possible to investigate plasma etching experiments on full-sheets at 7 nm resolution, opening the way to the integration of these polymers in chemoepitaxy stacks.
EUV local CDU healing performance and modeling capability towards 5nm node
NASA Astrophysics Data System (ADS)
Jee, Tae Kwon; Timoshkov, Vadim; Choi, Peter; Rio, David; Tsai, Yu-Cheng; Yaegashi, Hidetami; Koike, Kyohei; Fonseca, Carlos; Schoofs, Stijn
2017-10-01
Both local variability and optical proximity correction (OPC) errors are big contributors to the edge placement error (EPE) budget which is closely related to the device yield. The post-litho contact hole healing will be demonstrated to meet after-etch local variability specifications using a low dose, 30mJ/cm2 dose-to-size, positive tone developed (PTD) resist with relevant throughput in high volume manufacturing (HVM). The total local variability of the node 5nm (N5) contact holes will be characterized in terms of local CD uniformity (LCDU), local placement error (LPE), and contact edge roughness (CER) using a statistical methodology. The CD healing process has complex etch proximity effects, so the OPC prediction accuracy is challenging to meet EPE requirements for the N5. Thus, the prediction accuracy of an after-etch model will be investigated and discussed using ASML Tachyon OPC model.
Calnan, H B; Jacob, R H; Pethick, D W; Gardner, G E
2014-02-01
Spectrophotometric measures were used to determine the redness:browness (R630/R580) of 4238 lamb longissimus muscle after 3 days under simulated display. The results were analysed using linear mixed effects models. Environmental factors represented by effects such as kill group and site of production produced the greatest variation of up to 2.76 units in R630/R580. Isocitrate dehydrogenase activity, reflecting muscle oxidative capacity, reduced R630/R580 by 0.5 units. Selection for high muscling sires increased R630/R580 by 0.27 units, likely due to changes in muscle oxidative capacity. Lamb carcass weight also increased R630/R580 by 0.5 units. Analysis of genotypic factors influencing lamb size and growth rate such as sire type and dam breed further supported that increased growth rate improves meat R630/R580. Our findings suggest that breeding for increased growth rate and increased muscle weight could result in Australian lamb meat retaining its red colour for extended periods whilst on display. © 2013.
Cost Savings Associated with the LV 100-5 Tank Engine
2002-03-01
34 F. UNDER ARMOR AUXILLARY POWER UNIT...................................... 35 viii G. SUMMARY...48 E. UNDER ARMOR AUXILLARY POWER UNIT...................................... 49 F. SUMMARY...the gunner and commander thermal sights. An under armor auxiliary power unit, new computer mass memory unit, color maps and displays are included
micromap: A Package for Linked Micromaps
The R package micromap is used to create linked micromaps, which display statistical summaries associated with areal units, or polygons. Linked micromaps provide a means to simultaneously summarize and display both statistical and geographic distributions by linking statistical ...
Assessing the impact of PACS on patient care in a medical intensive care unit
NASA Astrophysics Data System (ADS)
Shile, Peter E.; Kundel, Harold L.; Seshadri, Sridhar B.; Carey, Bruce; Brikman, Inna; Kishore, Sheel; Feingold, Eric R.; Lanken, Paul N.
1993-09-01
In this paper we have present data from pilot studies to estimate the impact on patient care of an intensive care unit display station. The data were collected during two separate one-month periods in 1992. We compared these two different periods in terms of the relative speeds with which images were first viewed by MICU physicians. First, we found that images for routine chest radiographs (CXRs) are viewed by a greater number of physicians and slightly sooner with the PACS display station operating in the MICU than when it is not. Thus, for routine exams, PACS provide the potential for shortening of time intervals between exam completions and image-based clinical actions. A second finding is that the use of the display station for viewing non-routine CXRs is strongly influenced by the speed with which films are digitized. Hence, if film digitization is not rapid, the presence of a MICU display station is unlikely to contribute to a shortening of time intervals between exam completions and image-based clinical actions. This finding supports the use of computed radiography for CXRs in an intensive care unit.
Matuyama-age lithic tools from the Sima del Elefante site, Atapuerca (northern Spain).
Parés, Josep M; Pérez-González, Alfredo; Rosas, Antonio; Benito, A; Bermúdez de Castro, J M; Carbonell, E; Huguet, R
2006-02-01
Paleomagnetic results obtained from the sedimentary fill at the Sima del Elefante site in Atapuerca, Spain, reveal a geomagnetic reversal, interpreted as the Matuyama-Brunhes boundary (0.78 Ma). The uppermost lithostratigraphic units (E17 through E19), which contain Mode II and III archaeological assemblages, display normal polarity magnetization, whereas the six lowermost units (E9 through E16) yield negative latitudinal virtual geomagnetic pole positions. Units E9 through E13, all of which display reverse magnetic polarity, contain Mode I (Oldowan) lithic tools, testifying to the presence of humans in the early Pleistocene (0.78-1.77 Ma).
Pilot study of the domestic information display system in state and local government
NASA Technical Reports Server (NTRS)
1982-01-01
An interactive computer based system that can retrieve a wide range of data (demographic, environmental, socio-economic, etc.,) from a large data base and display these data for different geographic units in the form of choropleth maps was developed. The system was designed to display statistical information in a geographic format for national policy makers.
Wrap-Around Out-the-Window Sensor Fusion System
NASA Technical Reports Server (NTRS)
Fox, Jeffrey; Boe, Eric A.; Delgado, Francisco; Secor, James B.; Clark, Michael R.; Ehlinger, Kevin D.; Abernathy, Michael F.
2009-01-01
The Advanced Cockpit Evaluation System (ACES) includes communication, computing, and display subsystems, mounted in a van, that synthesize out-the-window views to approximate the views of the outside world as it would be seen from the cockpit of a crewed spacecraft, aircraft, or remote control of a ground vehicle or UAV (unmanned aerial vehicle). The system includes five flat-panel display units arranged approximately in a semicircle around an operator, like cockpit windows. The scene displayed on each panel represents the view through the corresponding cockpit window. Each display unit is driven by a personal computer equipped with a video-capture card that accepts live input from any of a variety of sensors (typically, visible and/or infrared video cameras). Software running in the computers blends the live video images with synthetic images that could be generated, for example, from heads-up-display outputs, waypoints, corridors, or from satellite photographs of the same geographic region. Data from a Global Positioning System receiver and an inertial navigation system aboard the remote vehicle are used by the ACES software to keep the synthetic and live views in registration. If the live image were to fail, the synthetic scenes could still be displayed to maintain situational awareness.
Definition of display/control requirements for assault transport night/adverse weather capability
NASA Technical Reports Server (NTRS)
Milelli, R. J.; Mowery, G. W.; Pontelandolfo, C.
1982-01-01
A Helicopter Night Vision System was developed to improve low-altitude night and/or adverse weather assult transport capabilities. Man-in-the-loop simulation experiments were performed to define the minimum display and control requirements for the assult transport mission and investigate forward looking infrared sensor requirements, along with alternative displays such as panel mounted displays (PMD) helmet mounted displays (HMD), and integrated control display units. Also explored were navigation requirements, pilot/copilot interaction, and overall cockpit arrangement. Pilot use of an HMD and copilot use of a PMD appear as both the preferred and most effective night navigation combination.
Prevention: lessons from video display installations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Margach, C.B.
1983-04-01
Workers interacting with video display units for periods in excess of two hours per day report significantly increased visual discomfort, fatigue and inefficiencies, as compared with workers performing similar tasks, but without the video viewing component. Difficulties in focusing and the appearance of myopia are among the problems being described. With a view to preventing or minimizing such problems, principles and procedures are presented providing for (a) modification of physical features of the video workstation and (b) improvement in the visual performances of the individual video unit operator.
Jahrome, Ommid K; Hoefer, Imo; Houston, Graeme J; Stonebridge, Peter A; Blankestijn, Peter J; Moll, Frans L; de Borst, Gert J
2011-01-01
The primary patency rate of arteriovenous (AV) grafts is limited by distal venous anastomosis stenosis or occlusion due to intimal hyperplasia associated with distal graft turbulence. The normal blood flow in native arteries is spiral laminar flow. Standard vascular grafts do not produce spiral laminar flow at the distal anastomosis. Vascular grafts which induce a spiral laminar flow distally result in lower turbulence, particularly near the vessel wall. This initial study compares the hemodynamic effects of a spiral flow-inducing graft and a standard graft in a new AV carotid to jugular vein crossover graft porcine model. Four spiral flow grafts and 4 control grafts were implanted from the carotid artery to the contralateral jugular vein in 4 pigs. Two animals were terminated after 48 hours and 2 at 14 days. Graft patency was assessed by selective catheter digital angiography, and the flow pattern was assessed by intraoperative flow probe and color Doppler ultrasound (CDU) measurements. The spiral grafts were also assessed at enhanced flow rates using an external roller pump to simulate increased flow rates that may occur during dialysis using a standard dialysis needle cannulation. The method increased the flow rate through the graft by 660 ml/min. The graft distal anastomotic appearances were evaluated by explant histopathology. All grafts were patent at explantation with no complications. All anastomoses were found to be wide open and showed no significant angiographic stenosis at the distal anastomosis in both spiral and control grafts. CDU examinations showed a spiral flow pattern in the spiral graft and double helix pattern in the control graft. No gross histopathological effects were seen in either spiral or control grafts. This porcine model is robust and allows hemodynamic flow assessment up to 14 days postimplantation. The spiral flow-inducing grafts produced and maintained spiral flow at baseline and enhanced flow rates during dialysis needle cannulation, whereas control grafts did not produce spiral flow through the distal anastomosis. There was no deleterious effect of the spiral flow-inducing graft on macroscopic and histological examination. The reducing effect of spiral flow on intima hyperplasia formation will be the subject of further study using the same AV graft model at a longer period of implantation.
Lee, Joo-Hyung; Lee, Hong-Seok; Lee, Byung-Kee; Choi, Won-Seok; Choi, Hwan-Young; Yoon, Jun-Bo
2007-09-15
A simple liquid crystal display (LCD) backlight unit (BLU) comprising only a single-sheet polydimethylsiloxane (PDMS) light-guide plate (LGP) has been developed. The PDMS LGP, having micropatterns with an inverse-trapezoidal cross section, was fabricated by backside 3-D diffuser lithography followed by PDMS-to-PDMS replication. The fabricated BLU showed an average luminance of 2878 cd/m(2) with 73.3% uniformity when mounted in a 5.08 cm backlight module with four side view 0.85cd LEDs. The developed BLU can greatly reduce the cost and thickness of LCDs, and it can be applied to flexible displays as a flexible light source due to the flexible characteristic of the PDMS itself.
Research on tactical information display technology for interactive virtual cockpit
NASA Astrophysics Data System (ADS)
Sun, Zhongyun; Tian, Tao; Su, Feng
2018-04-01
Based on a fact that traditional tactical information display technology suffers from disadvantages of a large number of data to be transferred and low plotting efficiency in an interactive virtual cockpit, a GID protocol-based simulation has been designed. This method dissolves complex tactical information screens into basic plotting units. The indication of plotting units is controlled via the plotting commands, which solves the incompatibility between the tactical information display in traditional simulation and the desktop-based virtual simulation training system. Having been used in desktop systems for helicopters, fighters, and transporters, this method proves to be scientific and reasonable in design and simple and efficient in usage, which exerts a significant value in establishing aviation equipment technology support training products.
Development of a Low Cost Graphics Terminal.
ERIC Educational Resources Information Center
Lehr, Ted
1985-01-01
Describes modifications made to expand the capabilities of a display unit (Lear Siegler ADM-3A) to include medium resolution graphics. The modifying circuitry is detailed along with software subroutined written in Z-80 machine language for controlling the video display. (JN)
Ranasinghe, Tharangi; Jeyaseelan, Deepa; White, Deirdre; Russo, Ray
2017-01-01
To evaluate parents' feedback regarding their experience in registering and accessing funding with the National Disability Insurance Scheme (NDIS) and communicating with the National Disability Insurance Agency (NDIA). Parents of children less than 7 years of age, who were assessed through the Child Development Unit (CDU) at the Women's and Children's Health Network from July 2013 to June 2014 and referred to the NDIS, were invited to complete a study questionnaire regarding their experience with the NDIS. The questionnaire was initially mailed to the parents. If no response was returned, families were telephoned to complete the questionnaire by phone or to be sent another copy of the questionnaire to complete. Of 121 children eligible for the study, 42 (34.7%) parents completed the questionnaire. Thirty-six (85.7%) parents reported having no difficulty with the NDIS registration process, while six parents (14.3%) had difficulty. With regards to accessing funding, 27 (64.3%) reported having no difficulty, 11 (26.2%) stated that it was difficult and 4 parents did not comment. Twenty-six parents (61.9%) reported that it was easy to communicate with the NDIA, while 12 (28.6%) found it difficult. Overall, 26 (61.9%) parents were satisfied with the NDIS and NDIA, 6 (14.8%) were unsatisfied and 9 (21.4%) were neutral. The majority of parents were satisfied with both the processes required to register and access funding through the NDIS for early intervention services for their children with developmental disabilities, and their ability to communicate with the NDIA. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
Needham, Amy; Cantlon, Jessica F; Ormsbee Holley, Susan M
2006-12-01
The current research investigates infants' perception of a novel object from a category that is familiar to young infants: key rings. We ask whether experiences obtained outside the lab would allow young infants to parse the visible portions of a partly occluded key ring display into one single unit, presumably as a result of having categorized it as a key ring. This categorization was marked by infants' perception of the keys and ring as a single unit that should move together, despite their attribute differences. We showed infants a novel key ring display in which the keys and ring moved together as one rigid unit (Move-together event) or the ring moved but the keys remained stationary throughout the event (Move-apart event). Our results showed that 8.5-month-old infants perceived the keys and ring as connected despite their attribute differences, and that their perception of object unity was eliminated as the distinctive attributes of the key ring were removed. When all of the distinctive attributes of the key ring were removed, the 8.5-month-old infants perceived the display as two separate units, which is how younger infants (7-month-old) perceived the key ring display with all its distinctive attributes unaltered. These results suggest that on the basis of extensive experience with an object category, infants come to identify novel members of that category and expect them to possess the attributes typical of that category.
Color Helmet-Mounted Display System for In-Flight Simulation on the RASCAL Research Helicopter
NASA Technical Reports Server (NTRS)
Edwards, Tim; Barnhart, Warren; Sawyer, Kevin; Aiken, Edwin W. (Technical Monitor)
1995-01-01
A high performance color helmet mounted display (HMD) system for in-flight simulation and research has been developed for the Rotorcraft Aircrew Systems Concepts Laboratory (RASCAL). The display system consists of a programmable display generator, a display electronics unit, a head tracker, and the helmet with display optics. The system provides a maximum of 1024 x 1280 resolution, a 4:1 contrast ratio, and a brightness of 1100fL utilizing currently available technologies. This paper describes the major features and components of the system. Also discussed are the measured performance of the system and the design techniques that allowed the development of a full color HMD.
14 CFR 45.23 - Display of marks; general.
Code of Federal Regulations, 2010 CFR
2010-01-01
... letter “N” (denoting United States registration) followed by the registration number of the aircraft....23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT IDENTIFICATION AND REGISTRATION MARKING Nationality and Registration Marks § 45.23 Display of marks; general. (a...
14 CFR 45.23 - Display of marks; general.
Code of Federal Regulations, 2011 CFR
2011-01-01
... letter “N” (denoting United States registration) followed by the registration number of the aircraft....23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT IDENTIFICATION AND REGISTRATION MARKING Nationality and Registration Marks § 45.23 Display of marks; general. (a...
14 CFR 45.23 - Display of marks; general.
Code of Federal Regulations, 2012 CFR
2012-01-01
... “N” (denoting United States registration) followed by the registration number of the aircraft. Each....23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT IDENTIFICATION AND REGISTRATION MARKING Nationality and Registration Marks § 45.23 Display of marks; general. (a...
14 CFR 45.23 - Display of marks; general.
Code of Federal Regulations, 2014 CFR
2014-01-01
... “N” (denoting United States registration) followed by the registration number of the aircraft. Each....23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT IDENTIFICATION AND REGISTRATION MARKING Nationality and Registration Marks § 45.23 Display of marks; general. (a...
14 CFR 45.23 - Display of marks; general.
Code of Federal Regulations, 2013 CFR
2013-01-01
... “N” (denoting United States registration) followed by the registration number of the aircraft. Each....23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT IDENTIFICATION AND REGISTRATION MARKING Nationality and Registration Marks § 45.23 Display of marks; general. (a...
Goto, Yasushi; Sekine, Ikuo; Sekiguchi, Hiroshi; Yamada, Kazuhiko; Nokihara, Hiroshi; Yamamoto, Noboru; Kunitoh, Hideo; Ohe, Yuichiro; Tamura, Tomohide
2009-07-01
Quality of information available over the Internet has been a cause for concern. Our goal was to evaluate the quality of information available on lung cancer in the United States and Japan and assess the differences between the two. We conducted a prospective, observational Web review by searching the word "lung cancer" in Japanese and English, using Google Japan (Google-J), Google United States (Google-U), and Yahoo Japan (Yahoo-J). The first 50 Web sites displayed were evaluated from the ethical perspective and for the validity of the information. The administrator of each Web site was also investigated. Ethical policies were generally well described in the Web sites displayed by Google-U but less well so in the sites displayed by Google-J and Yahoo-J. The differences in the validity of the information available was more striking, in that 80% of the Web sites generated by Google-U described the most appropriate treatment methods, whereas less than 50% of the Web sites displayed by Google-J and Yahoo-J recommended the standard therapy, and more than 10% advertised alternative therapy. Nonprofit organizations and public institutions were the primary Web site administrators in the United States, whereas commercial or personal Web sites were more frequent in Japan. Differences in the quality of information on lung cancer available over the Internet were apparent between Japan and the United States. The reasons for such differences might be tracked to the administrators of the Web sites. Nonprofit organizations and public institutions are the up-and-coming Web site administrators for relaying reliable medical information.
Battery electric vehicles - implications for the driver interface.
Neumann, Isabel; Krems, Josef F
2016-03-01
The current study examines the human-machine interface of a battery electric vehicle (BEV) from a user-perspective, focussing on the evaluation of BEV-specific displays, the relevance of provided information and challenges for drivers due to the concept of electricity in a road vehicle. A sample of 40 users drove a BEV for 6 months. Data were gathered at three points of data collection. Participants perceived the BEV-specific displays as only moderately reliable and helpful for estimating the displayed parameters. This was even less the case after driving the BEV for 3 months. A taxonomy of user requirements was compiled revealing the need for improved and additional information, especially regarding energy consumption and efficiency. Drivers had difficulty understanding electrical units and the energy consumption of the BEV. On the background of general principles for display design, results provide implications how to display relevant information and how to facilitate drivers' understanding of energy consumption in BEVs. Practitioner Summary: Battery electric vehicle (BEV) displays need to incorporate new information. A taxonomy of user requirements was compiled revealing the need for improved and additional information in the BEV interface. Furthermore, drivers had trouble understanding electrical units and energy consumption; therefore, appropriate assistance is required. Design principles which are specifically important in the BEV context are discussed.
Advanced autostereoscopic display for G-7 pilot project
NASA Astrophysics Data System (ADS)
Hattori, Tomohiko; Ishigaki, Takeo; Shimamoto, Kazuhiro; Sawaki, Akiko; Ishiguchi, Tsuneo; Kobayashi, Hiromi
1999-05-01
An advanced auto-stereoscopic display is described that permits the observation of a stereo pair by several persons simultaneously without the use of special glasses and any kind of head tracking devices for the viewers. The system is composed of a right eye system, a left eye system and a sophisticated head tracking system. In the each eye system, a transparent type color liquid crystal imaging plate is used with a special back light unit. The back light unit consists of a monochrome 2D display and a large format convex lens. The unit distributes the light of the viewers' correct each eye only. The right eye perspective system is combined with a left eye perspective system is combined with a left eye perspective system by a half mirror in order to function as a time-parallel stereoscopic system. The viewer's IR image is taken through and focused by the large format convex lens and feed back to the back light as a modulated binary half face image. The auto-stereoscopic display employs the TTL method as the accurate head tracking. The system was worked as a stereoscopic TV phone between Duke University Department Tele-medicine and Nagoya University School of Medicine Department Radiology using a high-speed digital line of GIBN. The applications are also described in this paper.
Young people's exposure to point-of-sale tobacco products and promotions.
Stead, M; Eadie, D; MacKintosh, A M; Best, C; Miller, M; Haseen, F; Pearce, J R; Tisch, C; Macdonald, L; MacGregor, A; Amos, A; van der Sluijs, W; Frank, J W; Haw, S
2016-07-01
Point of sale (POS) displays are one of the most important forms of tobacco marketing still permitted in many countries. Reliable methods for measuring exposure to such displays are needed in order to assess their potential impact, particularly on smoking attitudes and uptake among young people. In this study we use a novel method for evaluating POS exposure based on young people's use of retail outlets and recall of tobacco displays and observational data on the characteristics of displays. Observational audit of retail outlets (n = 96) and school-based pupil survey (n = 1482) in four Scottish communities reflecting different levels of social deprivation and urbanisation, conducted in 2013 before legislation to remove POS displays was implemented in supermarkets. Measures were taken of: visibility and placement of tobacco displays; internal and external advertising; display unit size, branding and design; visibility of pack warnings; proximity of tobacco products to products of potential interest to children and young people; pupils' self-reported frequency of visiting retail outlets; and pupils' recall of tobacco displays. Variation in POS exposure across social and demographic groups was assessed. Displays were highly visible within outlets and, in over half the stores, from the public footway outside. Tobacco products were displayed in close proximity to products of interest to children (e.g. confectionery, in 70% of stores). Eighty percent of pupils recalled seeing tobacco displays, with those from deprived areas more likely to recall displays in small shops. When confectioners, tobacconists and newsagents (CTNs) and grocery/convenience stores (two of the outlet types most often visited by young people) were examined separately, average tobacco display unit sizes were significantly larger in those outlets in more deprived areas. POS displays remain a key vector in most countries for advertising tobacco products, and it is important to develop robust measures of exposure. The data reported in this paper provide a baseline measure for evaluating the efficacy of legislation prohibiting such displays. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Teleoperator technology and system development, volume 1
NASA Technical Reports Server (NTRS)
1972-01-01
A two phase approach was undertaken to: (1) evaluate the performance of a general-purpose anthropomorphic manipulator with various controllers and display arrangements, (2) identify basic technical limitations of existing teleoperator designs, and associated controls and displays, and (3) identify, through experimentation, the effects that controls and displays have on the performance of an anthropomorphic manipulator. In Phase 1 the NASA-furnished manipulators, controls and displays were integrated with the remote maneuvering unit; in Phase 2 experiments were defined and performed to assess the utility of teleoperators for 6 typical space inspection, maintenance and repair tasks.
Weather information network including graphical display
NASA Technical Reports Server (NTRS)
Leger, Daniel R. (Inventor); Burdon, David (Inventor); Son, Robert S. (Inventor); Martin, Kevin D. (Inventor); Harrison, John (Inventor); Hughes, Keith R. (Inventor)
2006-01-01
An apparatus for providing weather information onboard an aircraft includes a processor unit and a graphical user interface. The processor unit processes weather information after it is received onboard the aircraft from a ground-based source, and the graphical user interface provides a graphical presentation of the weather information to a user onboard the aircraft. Preferably, the graphical user interface includes one or more user-selectable options for graphically displaying at least one of convection information, turbulence information, icing information, weather satellite information, SIGMET information, significant weather prognosis information, and winds aloft information.
The sodium pump α1 sub-unit: a disease progression–related target for metastatic melanoma treatment
Mathieu, Véronique; Pirker, Christine; Martin de Lassalle, Elisabeth; Vernier, Mathieu; Mijatovic, Tatjana; DeNeve, Nancy; Gaussin, Jean-François; Dehoux, Mischael; Lefranc, Florence; Berger, Walter; Kiss, Robert
2009-01-01
Melanomas remain associated with dismal prognosis because they are naturally resistant to apoptosis and they markedly metastasize. Up-regulated expression of sodium pump α sub-units has previously been demonstrated when comparing metastatic to non-metastatic melanomas. Our previous data revealed that impairing sodium pump α1 activity by means of selective ligands, that are cardiotonic steroids, markedly impairs cell migration and kills apoptosis-resistant cancer cells. The objective of this study was to determine the expression levels of sodium pump α sub-units in melanoma clinical samples and cell lines and also to characterize the role of α1 sub-units in melanoma cell biology. Quantitative RT-PCR, Western blotting and immunohistochemistry were used to determine the expression levels of sodium pump α sub-units. In vitro cytotoxicity of various cardenolides and of an anti-α1 siRNA was evaluated by means of MTT assay, quantitative videomicroscopy and through apoptosis assays. The in vivo activity of a novel cardenolide UNBS1450 was evaluated in a melanoma brain metastasis model. Our data show that all investigated human melanoma cell lines expressed high levels of the α1 sub-unit, and 33% of human melanomas displayed significant α1 sub-unit expression in correlation with the Breslow index. Furthermore, cardenolides (notably UNBS1450; currently in Phase I clinical trials) displayed marked anti-tumour effects against melanomas in vitro. This activity was closely paralleled by decreases in cMyc expression and by increases in apoptotic features. UNBS1450 also displayed marked anti-tumour activity in the aggressive human metastatic brain melanoma model in vivo. The α1 sodium pump sub-unit could represent a potential novel target for combating melanoma. PMID:19243476
Facebook Age Display and Alcohol Use among College Students
ERIC Educational Resources Information Center
Wilner, Molly; Kerr, Bradley; Moreno, Megan
2018-01-01
Background: This study aimed to investigate the relationship between Facebook age presentation, Facebook alcohol displays, and alcohol related risk factors among college students. Methods: Students from two universities in the United States enrolled and accepted a researcher's Facebook friend request. Participant's Facebook profiles were evaluated…
Direction discriminating hearing aid system
NASA Technical Reports Server (NTRS)
Jhabvala, M.; Lin, H. C.; Ward, G.
1991-01-01
A visual display was developed for people with substantial hearing loss in either one or both ears. The system consists of three discreet units; an eyeglass assembly for the visual display of the origin or direction of sounds; a stationary general purpose noise alarm; and a noise seeker wand.
39 CFR 447.42 - Additional prohibited political activities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 447.42 Postal Service UNITED STATES POSTAL SERVICE PERSONNEL RULES OF CONDUCT FOR POSTAL EMPLOYEES... restrictions on political activities mentioned in § 447.51, an employee may not: (1) Display a political... paragraph, however, from displaying a picture, including a personally autographed picture of a political...
Aberdeen polygons: computer displays of physiological profiles for intensive care.
Green, C A; Logie, R H; Gilhooly, K J; Ross, D G; Ronald, A
1996-03-01
The clinician in an intensive therapy unit is presented regularly with a range of information about the current physiological state of the patients under care. This information typically comes from a variety of sources and in a variety of formats. A more integrated form of display incorporating several physiological parameters may be helpful therefore. Three experiments are reported that explored the potential use of analogue, polygon diagrams to display physiological data from patients undergoing intensive therapy. Experiment 1 demonstrated that information can be extracted readily from such diagrams comprising 8- or 10-sided polygons, but with an advantage for simpler polygons and for information displayed at the top of the diagram. Experiment 2 showed that colour coding removed these biases for simpler polygons and the top of the diagram, together with speeding the processing time. Experiment 3 used polygons displaying patterns of physiological data that were consistent with typical conditions observed in the intensive care unit. It was found that physicians can readily learn to recognize these patterns and to diagnose both the nature and severity of the patient's physiological state. These polygon diagrams appear to have some considerable potential for use in providing on-line summary information of a patient's physiological state.
NASA Technical Reports Server (NTRS)
Gershzohn, Gary R.; Sirko, Robert J.; Zimmerman, K.; Jones, A. D.
1990-01-01
This task concerns the design, development, testing, and evaluation of a new proximity operations planning and flight guidance display and control system for manned space operations. A forecast, derivative manned maneuvering unit (MMU) was identified as a candidate for the application of a color, highway-in-the-sky display format for the presentation of flight guidance information. A silicon graphics 4D/20-based simulation is being developed to design and test display formats and operations concepts. The simulation includes the following: (1) real-time color graphics generation to provide realistic, dynamic flight guidance displays and control characteristics; (2) real-time graphics generation of spacecraft trajectories; (3) MMU flight dynamics and control characteristics; (4) control algorithms for rotational and translational hand controllers; (5) orbital mechanics effects for rendezvous and chase spacecraft; (6) inclusion of appropriate navigation aids; and (7) measurement of subject performance. The flight planning system under development provides for: (1) selection of appropriate operational modes, including minimum cost, optimum cost, minimum time, and specified ETA; (2) automatic calculation of rendezvous trajectories, en route times, and fuel requirements; (3) and provisions for manual override. Man/machine function allocations in planning and en route flight segments are being evaluated. Planning and en route data are presented on one screen composed of two windows: (1) a map display presenting a view perpendicular to the orbital plane, depicting flight planning trajectory and time data attitude display presenting attitude and course data for use en route; and (2) an attitude display presenting local vertical-local horizontal attitude data superimposed on a highway-in-the-sky or flight channel representation of the flight planned course. Both display formats are presented while the MMU is en route. In addition to these displays, several original display elements are being developed, including a 3DOF flight detector for attitude commanding, a different flight detector for translation commands, and a pictorial representation of velocity deviations.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-07
..., Modifications and Rulings: Certain Consumer Electronics and Display Devices and Products Containing Same AGENCY... the sale within the United States after importation of certain consumer electronics devices and..., Washington; LG Electronics, Inc. of Seoul, South Korea; LG Electronics, Mobilecomm U.S.A., Inc. of San Diego...
UAS Integration in the NAS Project: Detect and Avoid Display UNITED Demo
NASA Technical Reports Server (NTRS)
Roberts, Zachary
2017-01-01
This demo shows the UAS-NAS project's Vigilant Spirit Control Station developed in partnership with the U.S. Air Force Research Lab. Attendees will be able to view encounters and see how the DAA and TCAS II alerting and guidance displays are used to avoid simulated aircraft.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-13
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-807] Certain Digital Photo Frames and Image Display Devices and Components Thereof; Commission Determination Not To Review an Initial... importation, and the sale within the United States after importation of certain digital photo frames and image...
Official portrait of astronaut Jerry L. Ross
NASA Technical Reports Server (NTRS)
1988-01-01
Official portrait of Jerry L. Ross, United States Air Force (USAF) Colonel, member of Astronaut Class 9 (1980), and mission specialist. Ross wears extravehicular mobility unit (EMU) with EMU helmet displayed on table in front of him.
Photonic band gap structure simulator
Chen, Chiping; Shapiro, Michael A.; Smirnova, Evgenya I.; Temkin, Richard J.; Sirigiri, Jagadishwar R.
2006-10-03
A system and method for designing photonic band gap structures. The system and method provide a user with the capability to produce a model of a two-dimensional array of conductors corresponding to a unit cell. The model involves a linear equation. Boundary conditions representative of conditions at the boundary of the unit cell are applied to a solution of the Helmholtz equation defined for the unit cell. The linear equation can be approximated by a Hermitian matrix. An eigenvalue of the Helmholtz equation is calculated. One computation approach involves calculating finite differences. The model can include a symmetry element, such as a center of inversion, a rotation axis, and a mirror plane. A graphical user interface is provided for the user's convenience. A display is provided to display to a user the calculated eigenvalue, corresponding to a photonic energy level in the Brilloin zone of the unit cell.
Wide color gamut display with white and emerald backlighting.
Duan, Lvyin; Lei, Zhichun
2018-02-20
This paper proposes a wide color gamut approach that uses white and emerald lighting units as the backlight of the liquid crystal display. The white and emerald backlights are controlled by the image to be displayed. The mixing ratio of the white and the emerald lighting is analyzed so that the maximal color gamut coverage ratio can be achieved. Experimental results prove the effectiveness of the wide color gamut approach using white and emerald backlights.
Flat-panel display solutions for ground-environment military displays (Invited Paper)
NASA Astrophysics Data System (ADS)
Thomas, J., II; Roach, R.
2005-05-01
Displays for military vehicles have very distinct operational and cost requirements that differ from other military applications. These requirements demand that display suppliers to Army and Marine ground-environments provide low cost equipment that is capable of operation across environmental extremes. Inevitably, COTS components form the foundation of these "affordable" display solutions. This paper will outline the major display requirements and review the options that satisfy conflicting and difficult operational demands, using newly developed equipment as an example. Recently, a new supplier was selected for the Drivers Vision Enhancer (DVE) equipment, including the Display Control Module (DCM). The paper will outline the DVE and describe development of a new DCM solution. The DVE programme, with several thousand units presently in service and operational in conflicts such as "Operation Iraqi Freedom", represents a critical balance between cost and performance. We shall describe design considerations that include selection of COTS sources, the need to minimise display modification; video interfaces, power interfaces, operator interfaces and new provisions to optimise displayed video content.
Duval, Joseph S.
1995-01-01
This CD-ROM contains images generated from geophysical data, software for displaying and analyzing the images and software for displaying and examining profile data from aerial surveys flown as part of the National Uranium Resource Evaluation (NURE) Program of the U.S. Department of Energy. The images included are of gamma-ray data (uranium, thorium, and potassium channels), Bouguer gravity data, isostatic residual gravity data, aeromagnetic anomalies, topography, and topography with bathymetry. This publication contains image data for the conterminous United States and profile data for the conterminous United States within the area longitude 108 to 126 degrees W. and latitude 34 to 49 degrees N. The profile data include apparent surface concentrations of potassium, uranium, and thorium, the residual magnetic field, and the height above the ground. The images on this CD-ROM include graytone and color images of each data set, color shaded-relief images of the potential-field and topographic data, and color composite images of the gamma-ray data. The image display and analysis software can register images with geographic and geologic overlays. The profile display software permits the user to view the profiles as well as obtain data listings and export ASCII versions of data for selected flight lines.
Portable tester for determining gas content within a core sample
Garcia, Jr., Fred; Schatzel, Steven J.
1998-01-01
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas- a selector valve connected to the low and high range pressure transducers, a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container, and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use.
Portable tester for determining gas content within a core sample
Garcia, F. Jr.; Schatzel, S.J.
1998-04-21
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas; a selector valve connected to the low and high range pressure transducers and a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container; and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use. 5 figs.
Visualization of information with an established order
Wong, Pak Chung [Richland, WA; Foote, Harlan P [Richmond, WA; Thomas, James J [Richland, WA; Wong, Kwong-Kwok [Sugar Land, TX
2007-02-13
Among the embodiments of the present invention is a system including one or more processors operable to access data representative of a biopolymer sequence of monomer units. The one or more processors are further operable to establish a pattern corresponding to at least one fractal curve and generate one or more output signals corresponding to a number of image elements each representative of one of the monomer units. Also included is a display device responsive to the one or more output signals to visualize the biopolymer sequence by displaying the image elements in accordance with the pattern.
System and method for disrupting suspect objects
Gladwell, T. Scott; Garretson, Justin R; Hobart, Clinton G; Monda, Mark J
2013-07-09
A system and method for disrupting at least one component of a suspect object is provided. The system includes a source for passing radiation through the suspect object, a screen for receiving the radiation passing through the suspect object and generating at least one image therefrom, a weapon having a discharge deployable therefrom, and a targeting unit. The targeting unit displays the image(s) of the suspect object and aims the weapon at a disruption point on the displayed image such that the weapon may be positioned to deploy the discharge at the disruption point whereby the suspect object is disabled.
NASA Astrophysics Data System (ADS)
Cramer, Hugo; Mc Namara, Elliott; van Laarhoven, Rik; Jaganatharaja, Ram; de la Fuente, Isabel; Hsu, Sharon; Belletti, Filippo; Popadic, Milos; Tu, Ward; Huang, Wade
2017-03-01
The logic manufacturing process requires small in-device metrology targets to exploit the full dose correction potential of the modern scanners and process tools. A high-NA angular resolved scatterometer (YieldStar S-1250D) was modified to demonstrate the possibility of OCD measurements on 5x5µm2 targets. The results obtained on test wafers in a logic manufacturing environment, measured after litho and after core etch, showed a good correlation to larger reference targets and AEI to ADI intra-field CDU correlation, thereby demonstrating the feasibility of OCD on such small targets. The data was used to determine a reduction potential of 55% for the intra-field CD variation, using 145 points per field on a few inner fields, and 33% of the process induced across wafer CD variation using 16 points per field full wafer. In addition, the OCD measurements reveal valuable information on wafer-to-wafer layer height variations within a lot.
NASA Astrophysics Data System (ADS)
Wang, Fuming; Hunsche, Stefan; Anunciado, Roy; Corradi, Antonio; Tien, Hung Yu; Tang, Peng; Wei, Junwei; Wang, Yongjun; Fang, Wei; Wong, Patrick; van Oosten, Anton; van Ingen Schenau, Koen; Slachter, Bram
2018-03-01
We present an experimental study of pattern variability and defectivity, based on a large data set with more than 112 million SEM measurements from an HMI high-throughput e-beam tool. The test case is a 10nm node SRAM via array patterned with a DUV immersion LELE process, where we see a variation in mean size and litho sensitivities between different unique via patterns that leads to a seemingly qualitative differences in defectivity. The large available data volume enables further analysis to reliably distinguish global and local CDU variations, including a breakdown into local systematics and stochastics. A closer inspection of the tail end of the distributions and estimation of defect probabilities concludes that there is a common defect mechanism and defect threshold despite the observed differences of specific pattern characteristics. We expect that the analysis methodology can be applied for defect probability modeling as well as general process qualification in the future.
EUV process improvement with novel litho track hardware
NASA Astrophysics Data System (ADS)
Stokes, Harold; Harumoto, Masahiko; Tanaka, Yuji; Kaneyama, Koji; Pieczulewski, Charles; Asai, Masaya
2017-03-01
Currently, there are many developments in the field of EUV lithography that are helping to move it towards increased HVM feasibility. Targeted improvements in hardware design for advanced lithography are of interest to our group specifically for metrics such as CD uniformity, LWR, and defect density. Of course, our work is focused on EUV process steps that are specifically affected by litho track performance, and consequently, can be improved by litho track design improvement and optimization. In this study we are building on our experience to provide continual improvement for LWR, CDU, and Defects as applied to a standard EUV process by employing novel hardware solutions on our SOKUDO DUO coat develop track system. Although it is preferable to achieve such improvements post-etch process we feel, as many do, that improvements after patterning are a precursor to improvements after etching. We hereby present our work utilizing the SOKUDO DUO coat develop track system with an ASML NXE:3300 in the IMEC (Leuven, Belgium) cleanroom environment to improve aggressive dense L/S patterns.
NASA Astrophysics Data System (ADS)
Baik, Ki-Ho; Lem, Homer Y.; Dean, Robert L.; Osborne, Stephen; Mueller, Mark; Abboud, Frank E.
2003-08-01
In this paper, a process established with a positive-tone chemically amplified resist (CAR) from TOK REAP200 and Fujifilm Arch FEP171 and 50kV MEBES system is discussed. This TOK resist is developed for raster scan 50 kV e-beam systems. It has high contrast, good coating characteristics, good dry etch selectivity, and high environmental stability. In the mask industries, the most popular positive tone CAR is FEP171, which is a high activation energy type CAR. REAP (Raster E-beam Advanced Process) 200 is low activation energy type and new acetal protecting polymer. In this study, we compared to these different type resists in terms of contrast, PAB and PEB latitude, resist profile, footing, T-topping, PED stability, LER, Global CDU (Critical Dimension Uniformity) and resolution. The REAP200 Resist obtained 75nm isolated lines and spaces, 90nm dense patterns with vertical profile, and a good stability of delay time.
A biomedical information system for retrieval and manipulation of NHANES data.
Mukherjee, Sukrit; Martins, David; Norris, Keith C; Jenders, Robert A
2013-01-01
The retrieval and manipulation of data from large public databases like the U.S. National Health and Nutrition Examination Survey (NHANES) may require sophisticated statistical software and significant expertise that may be unavailable in the university setting. In response, we have developed the Data Retrieval And Manipulation System (DReAMS), an automated information system to handle all processes of data extraction and cleaning and then joining different subsets to produce analysis-ready output. The system is a browser-based data warehouse application in which the input data from flat files or operational systems are aggregated in a structured way so that the desired data can be read, recoded, queried and extracted efficiently. The current pilot implementation of the system provides access to a limited amount of NHANES database. We plan to increase the amount of data available through the system in the near future and to extend the techniques to other large databases from CDU archive with a current holding of about 53 databases.
[Analysis of the continuity, circulation and productivity of the Revista Española de Quimioterapia].
Gimeno Sieres, E
2007-06-01
The primary objective of this study was to compare some of the bibliometric indicators of the continuity, circulation and productivity of the Revista Espanola de Quimioterapia up to 2003 with other spanish journals of Pharmacy and Pharmacology. This was done by reviewing periodicals directories, such as the ISSN (International Standard Serial Number/Número Internacional Normalizado de Publicaciones Seriadas) and ULRICH'S (Periodicals Directory), as well as the CDU (Classification Universal Decimal), national and international databases including IME (Indice Médico Español), ICYT (Indice Espanol de Ciencia y Tecnologia), IPA (International Pharmaceutical Abstracts), SCI Expanded (Science Citation Index Expanded), MEDLINE (Index Medicus), EMBASE (Excerpta Medica), BIOSIS PREVIEWS, ANALYTICAL ABSTRACTS, FSTA (Food Science and Technology Abstracts), SCIFINDER SCHOLAR and CHEMISTRY CITATION INDEX. According to the results, the Revista Española de Quimioterapia, in publication for 15 years, is widely distributed and has a good rating among other scientific journals of the same discipline.
Top-coatless 193nm positive-tone development immersion resist for logic application
NASA Astrophysics Data System (ADS)
Liu, Lian Cong; Yeh, Tsung Ju; Lin, Yeh-Sheng; Huang, Yu Chin; Kuo, Chien Wen; Huang, Wen Liang; Lin, Chia Hung; Yu, Chun Chi; Hsu, Ray; Wan, I.-Yuan; Lin, Jeff; Im, Kwang-Hwyi; Lim, Hae Jin; Jeon, Hyun K.; Suzuki, Yasuhiro; Xu, Cheng Bai
2015-03-01
In this paper, we summarize our development efforts for a top-coatless 193nm immersion positive tone development (PTD) contact hole (C/H) resist with improved litho and defect performances for logic application specifically with an advance node. The ultimate performance goal was to improve the depth of focus (DoF) margin, mask error enhancement factor (MEEF), critical dimension uniformity (CDU), contact edge roughness (CER), and defect performance. Also, the through pitch CD difference was supposed to be comparable to the previous control resist. Effects of polymer and PAG properties have been evaluated for this purpose. The material properties focused in the evaluation study were polymer activation energy (Ea), polymer solubility differentiated by polymerization process types, and diffusion length (DL) and acidity (pKa) of photoacid generator (PAG). Additionally, the impact of post exposure bake (PEB) temperature was investigated for process condition optimization. As a result of this study, a new resist formulation to satisfy all litho and defect performance was developed and production yield was further improved.
3 CFR 8512 - Proclamation 8512 of April 29, 2010. Loyalty Day, 2010
Code of Federal Regulations, 2011 CFR
2011-01-01
... eagle with outstretched wings, clenching a banner in its beak with those powerful words emblazoned... the people of the United States to join in this national observance, to display the flag of the United...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-08
... its products accused of infringement include factory-installed GPS units in certain automobiles and certain after-market ``head-unit'' GPS devices that are mounted in automobile dashboards. On September 22... (202) [[Page 1081
Leadership Stability in Army Reserve Component Units
2013-01-01
or recognized, RC units could have more time because they may appear late in the force flow , particularly if AC units go earlier or the flow is...8, or deployment minus eight months), many new arrivals flowed into the unit, including many who would eventually deploy with the unit. Almost all...mobilization. Thus, those assigned are treated as 100 percent. To the right, we display the percentage (out of those assigned) who flowed into various
Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment
Mantilla, Carlos B.; Seven, Yasin B.; Sieck, Gary C.
2014-01-01
Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation, but are also active in other non-ventilatory behaviors, including coughing, sneezing, vomiting, defecation and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely-distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. PMID:24746055
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... temporary exhibition within the United States, are of cultural significance. The additional objects are... exhibition or display of the additional exhibit objects at The Metropolitan Museum of Art, New York, NY, from... at The Metropolitan Museum of Art, three of the works will continue to be displayed at The...
Automated cockpits special report, part 2.
1995-02-06
Part two of this report includes the following articles: Studies Highlight Automation 'Surprises'; Pilots Union Presses for Improved Displays; United Training Stresses Cockpit Discipline; Former NASA Ames Experts Hold Key Airline Posts; Aiding Mode Awareness; Military Cockpits Keep Autopilot Interface Simple; Gulfstream Using Vertical Profile Display; and, Data Recorders Crucial to State-of-art Crash Probes.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-26
..., now titled ``Display of Fraud Hotline Poster(s),'' to ``Display of Hotline Poster(s)'' and add the requirements for posting of additional types of hotline posters (regarding trafficking in persons and..., but require contractors to post these new posters when performing either inside or outside the United...
Self-Injurious Behavior, Self-Restraint, and Compulsive Behaviors in Cornelia de Lange Syndrome.
ERIC Educational Resources Information Center
Hyman, Philippa; Oliver, Chris; Hall, Scott
2002-01-01
Analysis of questionnaires completed by caregivers of 77 individuals with Cornelia de Lange syndrome in the United Kingdom found a significant association between self-injurious behaviors and self-restraint, and those displaying both behaviors displayed significantly more compulsions than did those not exhibiting them. Findings extend the…
Multimission helicopter cockpit displays
NASA Astrophysics Data System (ADS)
Terry, William S.; Terry, Jody K.; Lovelace, Nancy D.
1996-05-01
A new operator display subsystem is being incorporated as part of the next generation United States Navy (USN) helicopter avionics system to be integrated into the multi-mission helicopter (MMH) that replaces both the SH-60B and the SH-60F in 2001. This subsystem exploits state-of-the-art technology for the display hardware, the display driver hardware, information presentation methodologies, and software architecture. Both of the existing SH-60 helicopter display systems are based on monochrome CRT technology; a key feature of the MMH cockpit is the integration of color AMLCD multifunction displays. The MMH program is one of the first military programs to use modified commercial AMLCD elements in a tactical aircraft. This paper presents the general configuration of the MMH cockpit and multifunction display subsystem and discusses the approach taken for presenting helicopter flight information to the pilots as well as presentation of mission sensor data for use by the copilot.
Reverse-mode microdroplet liquid crystal display
NASA Astrophysics Data System (ADS)
Ma, Yao-Dong; Wu, Bao Gang; Xu, Gang
1990-04-01
This paper presents the production of the a reverse-mode microdroplet liquid crystal (RMLC) light shutter display. In this unit, the display is formed by a thin polymer film with dispersed liquid crystal microdroplets. The display is light transmissive in the absence of an applied electrical field. The display is converted to a non-transmissive state (i.e. absorbing or scattering) when an electrical field is applied. The "off' and "on" state. of this display are thus exactly opposite to that encountered in "normal-mode" microdroplet liquid crystal display devices such as polymer dispersed liquid crystals (PDLC)15 or Nematic Curvilinear Aligned Phase (NCAP)6. The Reverse Mode Microdroplet Liquid Crystal is obtained by modification of the surface energy of the polymer which encases liquid crystals via reaction of a dopant incorporated inside of the microdroplet during the droplet formation within the inside polymer layer. The liquid crystal used in RMLC is of negative dielectric anisotropy.
Architectural design of deep metallic sub-wavelength grating for practical holography display
NASA Astrophysics Data System (ADS)
Zhu, WenLiang; Shen, Chuan; Zhang, MingHua; Wei, Sui; Wang, XiangXiang; Wang, Ye
2017-10-01
Spatial light modulator (SLM) is the core device of holographic display, which requires a large space-bandwidth product (SBP), especially needing a wide viewing angle. According to the grating theory, the scale of the holographic display unit should be close to the wavelength of light. The transmission resonances of deep metallic sub-wavelength grating structure, which is produced by the surface plasmon and Fabry-Perot (FP) resonance based on metal grating phenomenon of Wood's anomaly, especially the metal-insulator-metal (MIM) structure provides a theoretical and effective technique for enhancing the reflection resonances and can be used for implementing the holographic display unit technology. In this paper, we replace the top electrode layer of the LCOS with a metallic deep sub-wavelength grating structure and change the grating period, slit width and spacer thickness. The simulation results by aid of CST software are given, which demonstrate that the improved device with dielectric medium parameter within liquid crystal refractive rate range (1.4 1.7) can reach 0 to 2π phase modulation in the visible wavelength range. Moreover, it also decrease the difficulty of device processing.
JSC MCC Bldg 30 Instrumentation and Communications Officer (INCO) RTDS
1988-06-02
Instrumentation and Communications Officer (INCO) John F. Muratore monitors conventional workstation displays during an STS-26 simulation in JSC Mission Control Center (MCC) Bldg 30 Flight Control Room (FCR). Next to Muratore an operator views the real time data system (RTDS), an expert system. During the STS-29 mission two conventional monochrome console display units will be removed and replaced with RTDS displays. View is for the STS-29 press kit from Office of Aeronautics and Space Technology (OAST) RTDS.
Swedish Defence Research Abstracts 78/79-3 (Froe Foersvars Forsknings Referat 78/79-3).
1979-11-01
including signal interception and technical intelligence (176) The JONAS -77 system: The Ag60 display terminal (177) Earthquake in Southern Germany on 3...F. Malmstr~m and H. Nygren December 1978 The present report discusses the use of a microprocessor in an apparatus to determine the direction of infra...E4 The JONAS -77 system: The Ag 60 display terminal Sture H~gosta June 1978 The JONAS comprises two Ag 60 display terminals, one in the central unit
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 1 2012-04-01 2012-04-01 false Commercial samples transported by automobile... Commercial samples transported by automobile through Canada between ports in the United States. (a) General... samples by automobile through Canada to another place in the United States without displaying the samples...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 1 2013-04-01 2013-04-01 false Commercial samples transported by automobile... Commercial samples transported by automobile through Canada between ports in the United States. (a) General... samples by automobile through Canada to another place in the United States without displaying the samples...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 1 2011-04-01 2011-04-01 false Commercial samples transported by automobile... Commercial samples transported by automobile through Canada between ports in the United States. (a) General... samples by automobile through Canada to another place in the United States without displaying the samples...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 1 2014-04-01 2014-04-01 false Commercial samples transported by automobile... Commercial samples transported by automobile through Canada between ports in the United States. (a) General... samples by automobile through Canada to another place in the United States without displaying the samples...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Commercial samples transported by automobile... Commercial samples transported by automobile through Canada between ports in the United States. (a) General... samples by automobile through Canada to another place in the United States without displaying the samples...
Color and Luminance Analysis of the Space Shuttle Multifunction Display Units(MDUs)
NASA Technical Reports Server (NTRS)
McCandless, Jeffrey W.
2003-01-01
The purpose of this evaluation is to measure and analyze the colors that can be shown on the Multifunction Display Units (MDUs) of the Space Shuttle cockpit. The evaluation was conducted in the JSC Avionics Engineering Laboratory (JAEL) in building 16A at NASA Johnson Space Center. The JAEL contains a suite of 11 MDUs, each of which can be configured to show colors based on input values of the MDU red, green and blue (RGB) channels. Each of the channels has a range of 0 to 15. For example, bright green is produced by setting RGB to 0,15,0, and orange is produced by setting RGB to 15,4,0. The Cockpit Avionics Upgrade (CAU) program has specified the RGB settings for 14 different colors in the Display Design document (Rev A, 29 June 2001). The analysis in this report may help the CAU program determine better RGB settings for the colors.
3 CFR 8993 - Proclamation 8993 of June 7, 2013. Flag Day and National Flag Week, 2013
Code of Federal Regulations, 2014 CFR
2014-01-01
... States to display the flag during that week. NOW, THEREFORE, I, BARACK OBAMA, President of the United... of the Independence of the United States of America the two hundred and thirty-seventh.BARACK OBAMA ...
Performance specification methodology: introduction and application to displays
NASA Astrophysics Data System (ADS)
Hopper, Darrel G.
1998-09-01
Acquisition reform is based on the notion that DoD must rely on the commercial marketplace insofar as possible rather than solely looking inward to a military marketplace to meet its needs. This reform forces a fundamental change in the way DoD conducts business, including a heavy reliance on private sector models of change. The key to more reliance on the commercial marketplace is the performance specifications (PS). This paper introduces some PS concepts and a PS classification principal to help bring some structure to the analysis of risk (cost, schedule, capability) in weapons system development and the management of opportunities for affordable ownership (maintain/increase capability via technology insertion, reduce cost) in this new paradigm. The DoD shift toward commercial components is nowhere better exemplified than in displays. Displays are the quintessential dual-use technology and are used herein to exemplify these PS concepts and principal. The advent of flat panel displays as a successful technology is setting off an epochal shift in cockpits and other military applications. Displays are installed in every DoD weapon system, and are, thus, representative of a range of technologies where issues and concerns throughout industry and government have been raised regarding the increased DoD reliance on the commercial marketplace. Performance specifications require metrics: the overall metrics of 'information-thrust' with units of Mb/s and 'specific info- thrust' with units of Mb/s/kg are introduced to analyze value of a display to the warfighter and affordability to the taxpayer.
Tactical Mission Command (TMC)
2016-03-01
capabilities to Army commanders and their staffs, consisting primarily of a user-customizable Common Operating Picture ( COP ) enabled with real-time... COP viewer and data management capability. It is a collaborative, visualization and planning application that also provides a common map display... COP ): Display the COP consisting of the following:1 Friendly forces determined by the commander including subordinate and supporting units at
STS-33 Commander Gregory displays Japanese student banner on OV-103's middeck
NASA Technical Reports Server (NTRS)
1989-01-01
STS-33 Commander Frederick D. Gregory displays banner drawn and signed by Japanese students on Discovery's, Orbiter Vehicle (OV) 103's, middeck. Gregory's right foot is positioned under the open airlock hatch. Behind him is the port side wall. Gregory wears shorts and a United States Air Force Academy (USAFA) t-shirt.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... Image Display Devices and Components Thereof; Notice of Request for Written Submissions on Remedy, the... importation, and the sale within the United States after importation of certain digital photo frames and image... the President, has 60 days to approve or disapprove the Commission's action. See section 337(j), 19 U...
Hamann, Claus; Martelon, MaryKate
2016-05-25
History supports the staff and single serpent, the asklepian, as the symbol of healing and medicine, yet its confusion with the caduceus (a winged staff with two snakes wrapped around it) persists. No population-based information on serpent symbol use exists. To determine the prevalence of asklepian and caduceus display among Internet images of medical and health professional schools' emblems, and to compare asklepian and caduceus display between medical and health professional schools, examining the effects of school longevity and geographic location on symbol display. This cross-sectional survey examined Internet websites and Google Images associated with medical and other health professional schools in the United States, Puerto Rico, and Canada from 2013 to 2015. The primary outcome was display of a traditional or variant asklepian or caduceus among current and past emblems in Google Images. Odds ratios (ORs) and 95% confidence intervals for the comparison of medical versus other health professional schools were calculated by logistic regression. Differences among schools' longevity were assessed with Student's t-tests and linear regression. Among images of current and past emblems of 482 schools-159 medical schools and 323 health professional schools-107 (22.2%) emblems displayed only the traditional, and 205 (42.5%) any, asklepian. Adjusting for geographic region and longevity, medical schools were 59% less likely than health professional schools to display the traditional asklepian (OR 0.41, 95% CI 0.24-0.71, P=.001), and were 7.7 times more likely than health professional schools to display the traditional caduceus. Medical schools were 8% less likely than health professional schools to display any asklepian (OR 0.92, 95% CI 0.62-1.38, P=.70), and were 3.3 times more likely than health professional schools to display any caduceus. Schools' preference of the asklepian over the caduceus confirmed historical origins. Less asklepian and more caduceus display by medical schools suggests an educational opportunity for the medical profession to define for itself and the public the correct symbol of an interdisciplinary mission of healing.
Wireless Augmented Reality Prototype (WARP)
NASA Technical Reports Server (NTRS)
Devereaux, A. S.
1999-01-01
Initiated in January, 1997, under NASA's Office of Life and Microgravity Sciences and Applications, the Wireless Augmented Reality Prototype (WARP) is a means to leverage recent advances in communications, displays, imaging sensors, biosensors, voice recognition and microelectronics to develop a hands-free, tetherless system capable of real-time personal display and control of computer system resources. Using WARP, an astronaut may efficiently operate and monitor any computer-controllable activity inside or outside the vehicle or station. The WARP concept is a lightweight, unobtrusive heads-up display with a wireless wearable control unit. Connectivity to the external system is achieved through a high-rate radio link from the WARP personal unit to a base station unit installed into any system PC. The radio link has been specially engineered to operate within the high- interference, high-multipath environment of a space shuttle or space station module. Through this virtual terminal, the astronaut will be able to view and manipulate imagery, text or video, using voice commands to control the terminal operations. WARP's hands-free access to computer-based instruction texts, diagrams and checklists replaces juggling manuals and clipboards, and tetherless computer system access allows free motion throughout a cabin while monitoring and operating equipment.
Activate/Inhibit KGCS Gateway via Master Console EIC Pad-B Display
NASA Technical Reports Server (NTRS)
Ferreira, Pedro Henrique
2014-01-01
My internship consisted of two major projects for the Launch Control System.The purpose of the first project was to implement the Application Control Language (ACL) to Activate Data Acquisition (ADA) and to Inhibit Data Acquisition (IDA) the Kennedy Ground Control Sub-Systems (KGCS) Gateway, to update existing Pad-B End Item Control (EIC) Display to program the ADA and IDA buttons with new ACL, and to test and release the ACL Display.The second project consisted of unit testing all of the Application Services Framework (ASF) by March 21st. The XmlFileReader was unit tested and reached 100 coverage. The XmlFileReader class is used to grab information from XML files and use them to initialize elements in the other framework elements by using the Xerces C++ XML Parser; which is open source commercial off the shelf software. The ScriptThread was also tested. ScriptThread manages the creation and activation of script threads. A large amount of the time was used in initializing the environment and learning how to set up unit tests and getting familiar with the specific segments of the project that were assigned to us.
The effect of rubber flooring on displaying stereotypies in gilts.
Ostović, Mario; Menčik, Sven; Kabalin, Anamaria Ekert; Gračner, Gordana Gregurić; Vučemilo, Marija; Matković, Kristina; Vukičević, Tajana Trbojević; Grahovac, Jurica; Pavičić, Zeljko
2015-01-01
The aim of the study was to assess the effect of rubber mats in service unit on displaying stereotypies in gilts. Four 28-day production cycles in all seasons were observed. Each cycle included 28 gilts housed in gestation stalls with slatted concrete floor, which was covered with adjusted mats for 14 gilts (experimental group), while the remaining 14 gilts served as controls. Display of stereotypies and other behaviours observed, mat manipulation and postural behaviours were estimated by direct 1-hour observation of gilts at 2-minute intervals after morning feed supply on days 1, 8, 15 and 28 of each cycle. During the study period, displaying stereotypies was significantly less frequent (P < 0.05) in experimental group as compared with control group. The rate of particular forms of stereotypies, i.e. vacuum chewing, bar biting and teeth grinding, was also significantly lower (P < 0.05 all) in experimental group throughout the study period. A significant negative correlation (P <.05) was found between the service unit air temperature and frequency of displaying stereotypies in control group, which could be attributed to the significantly more common standing posture (P < 0.05) in control gilts in the conditions of lower air temperature. During the cold period, experimental gilts took a lying position significantly more frequently (P < 0.05). In the experimental group of gilts there was no significant correlation (P > 0.05 all) between the frequency of displaying stereotypies and the frequency of lying and other postures observed, as well as between the stereotypy display and the air temperature. There was no significant correlation (P > 0.05 all) between the frequency of mat manipulation and displaying stereotypies in total or its particular forms, suggesting that the less pronounced stereotypy display in experimental gilts may have been influenced by factors other than those observed in the present study.
What are the underlying units of perceived animacy? Chasing detection is intrinsically object-based.
van Buren, Benjamin; Gao, Tao; Scholl, Brian J
2017-10-01
One of the most foundational questions that can be asked about any visual process is the nature of the underlying 'units' over which it operates (e.g., features, objects, or spatial regions). Here we address this question-for the first time, to our knowledge-in the context of the perception of animacy. Even simple geometric shapes appear animate when they move in certain ways. Do such percepts arise whenever any visual feature moves appropriately, or do they require that the relevant features first be individuated as discrete objects? Observers viewed displays in which one disc (the "wolf") chased another (the "sheep") among several moving distractor discs. Critically, two pairs of discs were also connected by visible lines. In the Unconnected condition, both lines connected pairs of distractors; but in the Connected condition, one connected the wolf to a distractor, and the other connected the sheep to a different distractor. Observers in the Connected condition were much less likely to describe such displays using mental state terms. Furthermore, signal detection analyses were used to explore the objective ability to discriminate chasing displays from inanimate control displays in which the wolf moved toward the sheep's mirror-image. Chasing detection was severely impaired on Connected trials: observers could readily detect an object chasing another object, but not a line-end chasing another line-end, a line-end chasing an object, or an object chasing a line-end. We conclude that the underlying units of perceived animacy are discrete visual objects.
Use of geographic information system to display water-quality data from San Juan basin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thorn, C.R.; Dam, W.L.
1989-09-01
The ARC/INFO geographic information system is creating thematic maps of the San Juan basin as part of the USGS Regional Aquifer-System Analysis program. (Use of trade names is for descriptive purposes only and does not constitute endorsement by the US Geological Survey.) Maps created by a Prime version of ARC/INFO, to be published in a series of Hydrologic Investigations Atlas reports for selected geologic units, will include outcrop patters, water-well locations, and water-quality data. The San Juan basin study area, encompassing about 19,400 mi{sup 2}, can be displayed with ARC/INFO at various scales; on the same scale, generated water-quality mapsmore » can be compared and overlain with other maps such as potentiometric surface and depth to top of a geologic or hydrologic unit. Selected water-quality and well data (including latitude and longitude) are retrieved from the USGS National Water Information System data base for a specified geologic unit. Data are formatted by Fortran programs and read into an INFO data base. Two parallel files - an INFO file containing water-quality data and well data and an ARC file containing the site coordinates - are joined to form the ARC/INFO data base. A file containing a series of commands using Prime's Command Procedure language is used to select coverage, display, and position data on the map. Data interpretation is enhanced by displaying water-quality data throughout the basin in combination with other hydrologic and geologic data.« less
An Infrared Data Acquisition and Processing System
1977-09-01
Display Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminai High Speed Printer/Plotter . . . . Digital Tape Unit...In addition to the recently procured Honeywell Model 96 analog re- corder, a High Density digital tape unit is planned. This unit will increase the...diagram of Figure 1 we see that a Digital Equipment Corp. (DEC) PDP-11/15 minicomputer with 28K of core memory drives the digital section of IRDAPS
Peñuelas-Urquides, Katia; Villarreal-Treviño, Licet; Silva-Ramírez, Beatriz; Rivadeneyra-Espinoza, Liliana; Said-Fernández, Salvador; de León, Mario Bermúdez
2013-01-01
The quantification of colony forming units (cfu), turbidity, and optical density at 600 nm (OD600) measurements were used to evaluate Mycobacterium tuberculosis growth. Turbidity and OD600 measurements displayed similar growth curves, while cfu quantification showed a continuous growth curve. We determined the cfu equivalents to McFarland and OD600 units. PMID:24159318
Peñuelas-Urquides, Katia; Villarreal-Treviño, Licet; Silva-Ramírez, Beatriz; Rivadeneyra-Espinoza, Liliana; Said-Fernández, Salvador; de León, Mario Bermúdez
2013-01-01
The quantification of colony forming units (cfu), turbidity, and optical density at 600 nm (OD600) measurements were used to evaluate Mycobacterium tuberculosis growth. Turbidity and OD600 measurements displayed similar growth curves, while cfu quantification showed a continuous growth curve. We determined the cfu equivalents to McFarland and OD600 units.
Know Your America: Suggested Study Course in Americanism. Revised Edition.
ERIC Educational Resources Information Center
American Legion, Indianapolis, IN. Americanism and Children's Youth Div.
The purpose of this booklet is to increase understanding of fundamental U.S. documents, the U.S. flag, patriotic institutions, and of San Francisco (California), March 14-16, 1986 of U.S. residents. Unit 2 describes and interprets the code of displaying the U.S. flag and provides a suggested flag education unit of study. Units 3 and 4 offer…
Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment.
Mantilla, Carlos B; Seven, Yasin B; Sieck, Gary C
2014-01-01
Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation but are also active in other nonventilatory behaviors, including coughing, sneezing, vomiting, defecation, and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly, properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors, whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing, or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. © 2014 Elsevier B.V. All rights reserved.
Yang, Chia-Chi; Su, Fong-Chin; Yang, Po-Ching; Lin, Hwai-Ting; Guo, Lan-Yuen
2016-01-01
Mechanical neck disorder is a widespread and non-neurological musculoskeletal condition resulting from modern lifestyles. Presently, the fundamental electrophysiological properties of the motor units of the sternocleidomastoid muscles and the characteristics of the short-term synchronization of the motor unit in patients with neck pain are ambiguous. This study therefore aims to clarify the fundamental electrophysiological properties of the motor units of the sternocleidomastoid muscles in patients with mechanical neck disorder and in asymptomatic individuals. We further investigated whether alterations in the degree of motor unit short-term synchronization occur. The surface electrophysiological signals of the bilateral sternal heads of the sternocleidomastoid muscles of twelve patients with mechanical neck disorder and asymptomatic individuals were detected at 25% of the maximum voluntary contraction during cervical isometric flexion and then decomposed into individual motor unit action potential trains. We found that the patients with mechanical neck disorder showed significantly higher initial and mean firing rates of the sternocleidomastoid muscles and displayed substantially lower motor unit short-term synchronization values compared with the asymptomatic subjects. Consequently, these convincing findings support the assertion that patients with mechanical neck disorder display altered neuromuscular control strategies, such as the reinforcement of motor unit recruitment firing rates in the sternocleidomastoid muscles. The motor units of these patients also revealed neural recruitment strategies with relatively poor efficiency when executing the required motor tasks.
Yang, Chia-Chi; Su, Fong-Chin; Yang, Po-Ching; Lin, Hwai-Ting
2016-01-01
Mechanical neck disorder is a widespread and non-neurological musculoskeletal condition resulting from modern lifestyles. Presently, the fundamental electrophysiological properties of the motor units of the sternocleidomastoid muscles and the characteristics of the short-term synchronization of the motor unit in patients with neck pain are ambiguous. This study therefore aims to clarify the fundamental electrophysiological properties of the motor units of the sternocleidomastoid muscles in patients with mechanical neck disorder and in asymptomatic individuals. We further investigated whether alterations in the degree of motor unit short-term synchronization occur. The surface electrophysiological signals of the bilateral sternal heads of the sternocleidomastoid muscles of twelve patients with mechanical neck disorder and asymptomatic individuals were detected at 25% of the maximum voluntary contraction during cervical isometric flexion and then decomposed into individual motor unit action potential trains. We found that the patients with mechanical neck disorder showed significantly higher initial and mean firing rates of the sternocleidomastoid muscles and displayed substantially lower motor unit short-term synchronization values compared with the asymptomatic subjects. Consequently, these convincing findings support the assertion that patients with mechanical neck disorder display altered neuromuscular control strategies, such as the reinforcement of motor unit recruitment firing rates in the sternocleidomastoid muscles. The motor units of these patients also revealed neural recruitment strategies with relatively poor efficiency when executing the required motor tasks. PMID:27941995
Identification, display, and use of symmetry elements in atomic and electronic structure models.
Khosrovani, N; Kung, P W; Freeman, C M; Gorman, A M; Kölmel, C M; Levine, S M; Newsam, J M
1999-01-01
Crystallographic symmetry plays an important role in structure determination from diffraction or scattering data, in spectroscopy and in simulations. It is convenient and insightful to integrate the display and use of such symmetry data with data analysis and modeling methods. We outline the integration of a suite of crystallographic algorithms, closely coupled with interactive graphical displays. These include techniques for identifying the unit cell of a solid, for automatically determining space and point group symmetries, for generalized displays of symmetry elements overlaid on structural models, and for construction, editing, and transformation of models subject to symmetry constraints. In addition, electron densities derived from periodic density functional calculations can be symmetrized and displayed with the corresponding symmetry elements. Applications of these various capabilities in crystallographic research are illustrated by topical examples.
Monitoring dynamic loads on wind tunnel force balances
NASA Technical Reports Server (NTRS)
Ferris, Alice T.; White, William C.
1989-01-01
Two devices have been developed at NASA Langley to monitor the dynamic loads incurred during wind-tunnel testing. The Balance Dynamic Display Unit (BDDU), displays and monitors the combined static and dynamic forces and moments in the orthogonal axes. The Balance Critical Point Analyzer scales and sums each normalized signal from the BDDU to obtain combined dynamic and static signals that represent the dynamic loads at predefined high-stress points. The display of each instrument is a multiplex of six analog signals in a way that each channel is displayed sequentially as one-sixth of the horizontal axis on a single oscilloscope trace. Thus this display format permits the operator to quickly and easily monitor the combined static and dynamic level of up to six channels at the same time.
3D display considerations for rugged airborne environments
NASA Astrophysics Data System (ADS)
Barnidge, Tracy J.; Tchon, Joseph L.
2015-05-01
The KC-46 is the next generation, multi-role, aerial refueling tanker aircraft being developed by Boeing for the United States Air Force. Rockwell Collins has developed the Remote Vision System (RVS) that supports aerial refueling operations under a variety of conditions. The system utilizes large-area, high-resolution 3D displays linked with remote sensors to enhance the operator's visual acuity for precise aerial refueling control. This paper reviews the design considerations, trade-offs, and other factors related to the selection and ruggedization of the 3D display technology for this military application.
49 CFR 1554.101 - Security Measures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... certificated repair stations located— (1) On airport. On an air operations area or security identification display area of an airport covered by an airport security program under 49 CFR part 1542 in the United States, or on the security restricted area of any commensurate airport outside the United States...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-30
... Ancient Mexico,'' imported from abroad for temporary exhibition within the United States, are of cultural... also determine that the exhibition or display of the exhibit objects at the Los Angeles County Museum... exhibition or display of the exhibit at the Dallas Museum of Art, Dallas, TX from on or about July 29, 2012...
Space Shuttle Placement Announcement
2011-04-12
Endeavour Vehicle Manager for United Space Alliance Mike Parrish speaks at an event where NASA Administrator Charles Bolden announced where four space shuttle orbiters will be permanently displayed at the conclusion of the Space Shuttle Program, Tuesday, April 12, 2011, at Kennedy Space Center in Cape Canaveral, Fla. The four orbiters, Enterprise, which currently is on display at the Smithsonian's Steven F. Udvar-Hazy Center near Washington Dulles International Airport, will move to the Intrepid Sea, Air & Space Museum in New York, Discovery will move to Udvar-Hazy, Endeavour will be displayed at the California Science Center in Los Angeles and Atlantis, in background, will be displayed at the Kennedy Space Center Visitor’s Complex. Photo Credit: (NASA/Bill Ingalls)
Display integration for ground combat vehicles
NASA Astrophysics Data System (ADS)
Busse, David J.
1998-09-01
The United States Army's requirement to employ high resolution target acquisition sensors and information warfare to increase its dominance over enemy forces has led to the need to integrate advanced display devices into ground combat vehicle crew stations. The Army's force structure require the integration of advanced displays on both existing and emerging ground combat vehicle systems. The fielding of second generation target acquisition sensors, color digital terrain maps and high volume digital command and control information networks on these platforms define display performance requirements. The greatest challenge facing the system integrator is the development and integration of advanced displays that meet operational, vehicle and human computer interface performance requirements for the ground combat vehicle fleet. The subject of this paper is to address those challenges: operational and vehicle performance, non-soldier centric crew station configurations, display performance limitations related to human computer interfaces and vehicle physical environments, display technology limitations and the Department of Defense (DOD) acquisition reform initiatives. How the ground combat vehicle Program Manager and system integrator are addressing these challenges are discussed through the integration of displays on fielded, current and future close combat vehicle applications.
Addressing Cultural Diversity: Effects of a Problem-Based Intercultural Learning Unit
ERIC Educational Resources Information Center
Busse, Vera; Krause, Ulrike-Marie
2015-01-01
This article explores to what extent a problem-based learning unit in combination with cooperative learning and affectively oriented teaching methods facilitates intercultural learning. As part of the study, students reflected on critical incidents, which display misunderstandings or conflicts that arise as a result of cultural differences. In…
Implementing the Big6: Context, Context, Context.
ERIC Educational Resources Information Center
Eisenberg, Mike
1998-01-01
Emphasizes the importance of context within the curriculum when implementing the Big6 information and technology skills. Curriculum mapping is described as a means of gathering and displaying information about curriculum units which can then be analyzed to select units and assignments best suited to integrated information and technology skills…
Military display market: third comprehensive edition
NASA Astrophysics Data System (ADS)
Desjardins, Daniel D.; Hopper, Darrel G.
2002-08-01
Defense displays comprise a niche market whose continually high performance requirements drive technology. The military displays market is being characterized to ascertain opportunities for synergy across platforms, and needs for new technology. All weapons systems are included. Some 382,585 displays are either now in use or planned in DoD weapon systems over the next 15 years, comprising displays designed into direct-view, projection-view, and virtual- image-view applications. This defense niche market is further fractured into 1163 micro-niche markets by the some 403 program offices who make decisions independently of one another. By comparison, a consumer electronics product has volumes of tens-of-millions of units for a single fixed design. Some 81% of defense displays are ruggedized versions of consumer-market driven designs. Some 19% of defense displays, especially in avionics cockpits and combat crewstations, are custom designs to gain the additional performance available in the technology base but not available in consumer-market-driven designs. Defense display sizes range from 13.6 to 4543 mm. More than half of defense displays are now based on some form of flat panel display technology, especially thin-film-transistor active matrix liquid crystal display (TFT AMLCD); the cathode ray tube (CRT) is still widely used but continuing to drop rapidly in defense market share.
Gómez-Urquiza, Jose L; Hueso-Montoro, César; Urquiza-Olmo, Josefa; Ibarrondo-Crespo, Rocío; González-Jiménez, Emilio; Schmidt-Riovalle, Jacqueline
2016-07-01
To determine the effectiveness of photographic display at reducing pre-operative anxiety in an ear, nose and throat surgery unit; alone and in combination with music. The waiting time prior to the surgery is often unpleasant and a time of anxiety for patients. Anxiety can affect physical recovery and psychological well-being; lengthening convalescence and hospital stay after the surgery. Improving pre-operative anxiety is a challenge with potential impacts on improving patients' satisfaction and well-being and decreasing the cost of care. A clinical trial was conducted with two intervention groups and one control group. The sample consisted of 180 subjects from the otolaryngology major ambulatory surgery unit in a tertiary hospital in the province of Granada, with 60 subjects per group. The outcome variables measured were state anxiety, heart and respiratory rate and blood pressure. The data were collected from May-December 2013. After the intervention, in the comparison between control group and photographic display group, all variables had lower means in the intervention group, although a significant P value was only obtained for respiratory rate using one-way anova test. When comparing control group and photographic display combined with music group, using one-way anova test, all mean values were lower in the intervention group and a significant P value were observed for all variables except diastolic blood pressure. Photographic display in combination with music is more effective at reducing pre-operative anxiety than the standard intervention and photographic display alone. © 2016 John Wiley & Sons Ltd.
Complex behavior in chains of nonlinear oscillators.
Alonso, Leandro M
2017-06-01
This article outlines sufficient conditions under which a one-dimensional chain of identical nonlinear oscillators can display complex spatio-temporal behavior. The units are described by phase equations and consist of excitable oscillators. The interactions are local and the network is poised to a critical state by balancing excitation and inhibition locally. The results presented here suggest that in networks composed of many oscillatory units with local interactions, excitability together with balanced interactions is sufficient to give rise to complex emergent features. For values of the parameters where complex behavior occurs, the system also displays a high-dimensional bifurcation where an exponentially large number of equilibria are borne in pairs out of multiple saddle-node bifurcations.
NASA Technical Reports Server (NTRS)
1990-01-01
SPATE 900 Dynamic Stress Analyzer is an acronym for Stress Pattern Analysis by Thermal Emission. It detects stress-induced temperature changes in a structure and indicates the degree of stress. Ometron, Inc.'s SPATE 9000 consists of a scan unit and a data display. The scan unit contains an infrared channel focused on the test structure to collect thermal radiation, and a visual channel used to set up the scan area and interrogate the stress display. Stress data is produced by detecting minute temperature changes, down to one-thousandth of a degree Centigrade, resulting from the application to the structure of dynamic loading. The electronic data processing system correlates the temperature changes with a reference signal to determine stress level.
Apparatus and method for imaging metallic objects using an array of giant magnetoresistive sensors
Chaiken, Alison
2000-01-01
A portable, low-power, metallic object detector and method for providing an image of a detected metallic object. In one embodiment, the present portable low-power metallic object detector an array of giant magnetoresistive (GMR) sensors. The array of GMR sensors is adapted for detecting the presence of and compiling image data of a metallic object. In the embodiment, the array of GMR sensors is arranged in a checkerboard configuration such that axes of sensitivity of alternate GMR sensors are orthogonally oriented. An electronics portion is coupled to the array of GMR sensors. The electronics portion is adapted to receive and process the image data of the metallic object compiled by the array of GMR sensors. The embodiment also includes a display unit which is coupled to the electronics portion. The display unit is adapted to display a graphical representation of the metallic object detected by the array of GMR sensors. In so doing, a graphical representation of the detected metallic object is provided.
NASA Technical Reports Server (NTRS)
Glover, R. D.
1983-01-01
The NASA Dryden Flight Research Facility has developed a microprocessor-based, user-programmable, general-purpose aircraft interrogation and display system (AIDS). The hardware and software of this ground-support equipment have been designed to permit diverse applications in support of aircraft digital flight-control systems and simulation facilities. AIDS is often employed to provide engineering-units display of internal digital system parameters during development and qualification testing. Such visibility into the system under test has proved to be a key element in the final qualification testing of aircraft digital flight-control systems. Three first-generation 8-bit units are now in service in support of several research aircraft projects, and user acceptance has been high. A second-generation design, extended AIDS (XAIDS), incorporating multiple 16-bit processors, is now being developed to support the forward swept wing aircraft project (X-29A). This paper outlines the AIDS concept, summarizes AIDS operational experience, and describes the planned XAIDS design and mechanization.
Bowers, Janice E.
2006-01-01
The capacity of individual branches to store water and fix carbon can have profound effects on inflorescence size and architecture, thus on floral display, pollination, and fecundity. Mixed regression was used to investigate the relation between branch length, a proxy for plant resources, and floral display of Fouquieria splendens (ocotillo), a woody, candelabraform shrub of wide distribution in arid North America. Long branches produced three times as many flowers as short branches, regardless of overall plant size. Long branches also had more complex panicles with more cymes and cyme types than short branches; thus, branch length also influenced inflorescence architecture. Within panicles, increasing the number of cymes by one unit added about two flowers, whereas increasing the number of cyme types by one unit added about 21 flowers. Because flower production is mediated by branch length, and because most plants have branches of various lengths, the floral display of individual plants necessarily encompasses a wide range of inflorescence size and structure. ?? Springer 2006.
Maij, David L R; van Harreveld, Frenk; Gervais, Will; Schrag, Yann; Mohr, Christine; van Elk, Michiel
2017-01-01
The ability to mentalize has been marked as an important cognitive mechanism enabling belief in supernatural agents. In five studies we cross-culturally investigated the relationship between mentalizing and belief in supernatural agents with large sample sizes (over 67,000 participants in total) and different operationalizations of mentalizing. The relative importance of mentalizing for endorsing supernatural beliefs was directly compared with credibility enhancing displays-the extent to which people observed credible religious acts during their upbringing. We also compared autistic with neurotypical adolescents. The empathy quotient and the autism-spectrum quotient were not predictive of belief in supernatural agents in all countries (i.e., The Netherlands, Switzerland and the United States), although we did observe a curvilinear effect in the United States. We further observed a strong influence of credibility enhancing displays on belief in supernatural agents. These findings highlight the importance of cultural learning for acquiring supernatural beliefs and ask for reconsiderations of the importance of mentalizing.
Optimal front light design for reflective displays under different ambient illumination
NASA Astrophysics Data System (ADS)
Wang, Sheng-Po; Chang, Ting-Ting; Li, Chien-Ju; Bai, Yi-Ho; Hu, Kuo-Jui
2011-01-01
The goal of this study is to find out the optimal luminance and color temperature of front light for reflective displays in different ambient illumination by conducting series of psychophysical experiments. A color and brightness tunable front light device with ten LED units was built and been calibrated to present 256 luminance levels and 13 different color temperature at fixed luminance of 200 cd/m2. The experiment results revealed the best luminance and color temperature settings for human observers under different ambient illuminant, which could also assist the e-paper manufacturers to design front light device, and present the best image quality on reflective displays. Furthermore, a similar experiment procedure was conducted by utilizing new flexible e-signage display developed by ITRI and an optimal front light device for the new display panel has been designed and utilized.
One-man, self-contained CO2 concentrating system
NASA Technical Reports Server (NTRS)
Wynveen, R. A.; Schubert, F. H.; Powell, J. D.
1972-01-01
A program to design, fabricate, and test a 1-man, self-contained, electrochemical CO2 concentrating system is described. The system was designed with electronic controls and instrumentation to regulate performance, to analyze and display performance trends, and to detect and isolate faults. Ground support accessories were included to provide power, fluids, and a Parametric Data Display allowing real time indication of operating status in engineering units.
NASA Astrophysics Data System (ADS)
Li-bo, Dang; Jia-chun, Wu; Yue-xing, Liu; Yuan, Chang; Bin, Peng
2017-04-01
Underground coal fire (UCF) is serious in Xinjiang region of China. In order to deal with this problem efficiently, a UCF monitoring System, which is based on the use of wireless communication technology and remote sensing images, was designed and implemented by Xinjiang Coal Fire Fighting Bureau. This system consists of three parts, i.e., the data collecting unit, the data processing unit and the data output unit. For the data collecting unit, temperature sensors and gas sensors were put together on the sites with depth of 1.5 meter from the surface of coal fire zone. Information on these sites' temperature and gas was transferred immediately to the data processing unit. The processing unit was developed by coding based on GIS software. Generally, the processed datum were saved in the computer by table format, which can be displayed on the screen as the curve. Remote sensing image for each coal fire was saved in this system as the background for each monitoring site. From the monitoring data, the changes of the coal fires were displayed directly. And it provides a solid basis for analyzing the status of coal combustion of coal fire, the gas emission and possible dominant direction of coal fire propagation, which is helpful for making-decision of coal fire extinction.
Microchannel plate for high-efficiency field emission display
NASA Astrophysics Data System (ADS)
Yi, Whikun; Jin, Sunghwan; Jeong, Taewon; Lee, Jeonghee; Yu, SeGi; Choi, Yongsoo; Kim, J. M.
2000-09-01
The efficiency of a field emission display was improved significantly with a newly developed microchannel plate. The key features of this unit and its fabrication are summarized as follows: (a) bulk alumina is used as a substrate material, (b) channel location is defined by a programed-hole puncher, and (c) thin film deposition is conducted by electroless plating followed by a sol-gel process. With the microchannel plate between the cathode and the anode of a field emission display, the brightness of luminescent light increases three- to fourfold by electron multiplication through an array of pores in the device. In addition, the fabricated microchannel plate prevents spreading of electrons emitted from the cathode tips, thus improving both display resolution and picture quality.
Stereoscopic display technologies for FHD 3D LCD TV
NASA Astrophysics Data System (ADS)
Kim, Dae-Sik; Ko, Young-Ji; Park, Sang-Moo; Jung, Jong-Hoon; Shestak, Sergey
2010-04-01
Stereoscopic display technologies have been developed as one of advanced displays, and many TV industrials have been trying commercialization of 3D TV. We have been developing 3D TV based on LCD with LED BLU (backlight unit) since Samsung launched the world's first 3D TV based on PDP. However, the data scanning of panel and LC's response characteristics of LCD TV cause interference among frames (that is crosstalk), and this makes 3D video quality worse. We propose the method to reduce crosstalk by LCD driving and backlight control of FHD 3D LCD TV.
Multimission helicopter information display technology
NASA Astrophysics Data System (ADS)
Terry, William S.
1995-06-01
A new Operator display subsystem is being incorporated as part of the next generation United States Navy (USN) helicopter avionics system to be integrated into the Multi-Mission Helicopter (MMH) which will replace both the SH-60B and the SH- 60F in 2001. This subsystem exploits state-of-the-art technology for the display hardware, the display driver hardware, information presentation methodologies, and software architecture. The technologies to be base technologies have evolved during the development period and the solution has been modified to include current elements including high resolution AMLCD color displays that are sunlight readable, highly reliable, and significantly lighter that CRT technology, as well as Reduced Instruction Set Computer (RISC) based high-performance display generators that have only recently become feasible to implement in a military aircraft. This paper describes the overall subsystem architecture, some detail on the individual elements along with supporting rationale, the manner in which the display subsystem provides the necessary tools to significantly enhance the performance of the weapon system through the vital Operator-System Interface. Also addressed is a summary of the evolution of design leading to the current approach to MMH Operator displays and display processing as well as the growth path that the MMH display subsystem will most likely follow as additional technology evolution occurs.
16 CFR 1616.31 - Labeling, recordkeeping, retail display and guaranties.
Code of Federal Regulations, 2010 CFR
2010-01-01
... process of manufacture of each production unit of articles of children's sleepwear, or fabrics or related... production unit or by style. A style is a garment design or grouping, preselected by the manufacturer. A... garment design or on the garment packages. A style is a garment design or grouping, preselected by the...
16 CFR 1615.31 - Labeling, recordkeeping, advertising, retail display and guaranties.
Code of Federal Regulations, 2010 CFR
2010-01-01
... records required must establish a line of continuity through the process of manufacture of each production... manufacturing specifications relating the same to prototype and production testing and to the production units... such sale or delivery shall be identified by production unit or by style. A style is a garment design...
ERIC Educational Resources Information Center
Blandford, A. E.; Smith, P. R.
1986-01-01
Describes the style of design of computer simulations developed by Computer Assisted Teaching Unit at Queen Mary College with reference to user interface, input and initialization, input data vetting, effective display screen use, graphical results presentation, and need for hard copy. Procedures and problems relating to academic involvement are…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-25
... infringing inventory. FOR FURTHER INFORMATION CONTACT: James R. Holbein, Secretary to the Commission, U.S... if the Commission finds a violation it shall exclude the articles concerned from the United States... conditions in the United States economy, the production of like or directly competitive articles in the...
ERIC Educational Resources Information Center
Wastell, Sarah; Skirrow, Paul; Hare, Dougal Julian
2016-01-01
Objectives: The use of pharmacological interventions to manage challenging behaviour displayed by adults with intellectual disabilities remains controversial, with current clinical guidelines in the United Kingdom advocating the use of less invasive psychological interventions. This exploratory study aimed to discover what views and beliefs are…
Deflection or Azimuth: Which Direction Should the United States Field Artillery Follow?
1992-06-05
FUNDING NUMBERS reflection or Azimuth; Which Direction Should The United States Field Artillery FolIlo W? 6. AUTHOR(S) VIAJ James M. McDonald, USA 7...system that displays distinct advantages in the safety arena is certainly worthy of evaluation and consideration as a possible system to use
Database of Sources of Environmental Releases of Dioxin-Like Compounds in the United States
Thomas S. Frieswyk; Anne M. Malley
1985-01-01
This is a statistical report on the fourth forest survey of New Hampshire conducted in 1982-83 by the Forest Inventory and Analysis Unit, Northeastern Forest Experiment Station. Statistics for forest area, numbers of trees, timber volume, tree biomass, and timber products output are displayed at the state, unit, and county levels. The current inventory indicates that...
Messier, Erik
2016-08-01
A Multichannel Systems (MCS) microelectrode array data acquisition (DAQ) unit is used to collect multichannel electrograms (EGM) from a Langendorff perfused rabbit heart system to study sudden cardiac death (SCD). MCS provides software through which data being processed by the DAQ unit can be displayed and saved, but this software's combined utility with MATLAB is not very effective. MCSs software stores recorded EGM data in a MathCad (MCD) format, which is then converted to a text file format. These text files are very large, and it is therefore very time consuming to import the EGM data into MATLAB for real-time analysis. Therefore, customized MATLAB software was developed to control the acquisition of data from the MCS DAQ unit, and provide specific laboratory accommodations for this study of SCD. The developed DAQ unit control software will be able to accurately: provide real time display of EGM signals; record and save EGM signals in MATLAB in a desired format; and produce real time analysis of the EGM signals; all through an intuitive GUI.
NASA Technical Reports Server (NTRS)
Groce, J. L.; Boucek, G. P.
1988-01-01
This study is a continuation of an FAA effort to alleviate the growing problems of assimilating and managing the flow of data and flight related information in the air transport flight deck. The nature and extent of known pilot interface problems arising from new NAS data management programs were determined by a comparative timeline analysis of crew tasking requirements. A baseline of crew tasking requirements was established for conventional and advanced flight decks operating in the current NAS environment and then compared to the requirements for operation in a future NAS environment emphasizing Mode-S data link and TCAS. Results showed that a CDU-based pilot interface for Mode-S data link substantially increased crew visual activity as compared to the baseline. It was concluded that alternative means of crew interface should be available during high visual workload phases of flight. Results for TCAS implementation showed substantial visual and motor tasking increases, and that there was little available time between crew tasks during a TCAS encounter. It was concluded that additional research should be undertaken to address issues of ATC coordination and the relative benefit of high workload TCAS features.
Measurement of luminance and color uniformity of displays using the large-format scanner
NASA Astrophysics Data System (ADS)
Mazikowski, Adam
2017-08-01
Uniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce satisfactory results, so a different solution is proposed in the paper. The developed system consists of the large-format X-Y-Z ISEL scanner (isel Germany AG), Konica Minolta high sensitivity spot photometer-colorimeter (e.g. CS-200, Konica Minolta, Inc.) and PC computer. Dedicated software in LabView environment for control of the scanner, transfer the measured data to the computer, and visualization of measurement results was also prepared. Based on the developed setup measurements of plasma display and LCD-LED display were performed. A heavily wornout plasma TV unit, with several artifacts visible was selected. These tests show the advantages and drawbacks of described scanning method with comparison with 9-point simplified uniformity determining method.
Interactive display of molecular models using a microcomputer system
NASA Technical Reports Server (NTRS)
Egan, J. T.; Macelroy, R. D.
1980-01-01
A simple, microcomputer-based, interactive graphics display system has been developed for the presentation of perspective views of wire frame molecular models. The display system is based on a TERAK 8510a graphics computer system with a display unit consisting of microprocessor, television display and keyboard subsystems. The operating system includes a screen editor, file manager, PASCAL and BASIC compilers and command options for linking and executing programs. The graphics program, written in USCD PASCAL, involves the centering of the coordinate system, the transformation of centered model coordinates into homogeneous coordinates, the construction of a viewing transformation matrix to operate on the coordinates, clipping invisible points, perspective transformation and scaling to screen coordinates; commands available include ZOOM, ROTATE, RESET, and CHANGEVIEW. Data file structure was chosen to minimize the amount of disk storage space. Despite the inherent slowness of the system, its low cost and flexibility suggests general applicability.
The application of autostereoscopic display in smart home system based on mobile devices
NASA Astrophysics Data System (ADS)
Zhang, Yongjun; Ling, Zhi
2015-03-01
Smart home is a system to control home devices which are more and more popular in our daily life. Mobile intelligent terminals based on smart homes have been developed, make remote controlling and monitoring possible with smartphones or tablets. On the other hand, 3D stereo display technology developed rapidly in recent years. Therefore, a iPad-based smart home system adopts autostereoscopic display as the control interface is proposed to improve the userfriendliness of using experiences. In consideration of iPad's limited hardware capabilities, we introduced a 3D image synthesizing method based on parallel processing with Graphic Processing Unit (GPU) implemented it with OpenGL ES Application Programming Interface (API) library on IOS platforms for real-time autostereoscopic displaying. Compared to the traditional smart home system, the proposed system applied autostereoscopic display into smart home system's control interface enhanced the reality, user-friendliness and visual comfort of interface.
1988-06-17
Two difinitions have been devised to quantify contrast. Contrast ratio is given by - L2CR= = L (1) in which L2 and Li are luminance measurements and L2...units, which are quantitative , well understood, and predictable, before the display hardware is built. The last advantage is economically important in...then estimate quantitatively the effect of the resultant MTF change on user performance. 10 The reader interested in probing MTF in further depth is
Time and number of displays impact critical signal detection in fetal heart rate tracings.
Anderson, Brittany L; Scerbo, Mark W; Belfore, Lee A; Abuhamad, Alfred Z
2011-06-01
Interest in centralized monitoring in labor and delivery units is growing because it affords the opportunity to monitor multiple patients simultaneously. However, a long history of research on sustained attention reveals these types of monitoring tasks can be problematic. The goal of the present experiment was to examine the ability of individuals to detect critical signals in fetal heart rate (FHR) tracings in one or more displays over an extended period of time. Seventy-two participants monitored one, two, or four computer-simulated FHR tracings on a computer display for the appearance of late decelerations over a 48-minute vigil. Measures of subjective stress and workload were also obtained before and after the vigil. The results showed that detection accuracy decreased over time and also declined as the number of displays increased. The subjective reports indicated that participants found the task to be stressful and mentally demanding, effortful, and frustrating. The results suggest that centralized monitoring that allows many patients to be monitored simultaneously may impose a detrimental attentional burden on the observer. Furthermore, this seemingly benign task may impose an additional source of stress and mental workload above what is commonly found in labor and delivery units. © Thieme Medical Publishers.
Xu, Jing; Wong, Kevin; Jian, Yifan; Sarunic, Marinko V
2014-02-01
In this report, we describe a graphics processing unit (GPU)-accelerated processing platform for real-time acquisition and display of flow contrast images with Fourier domain optical coherence tomography (FDOCT) in mouse and human eyes in vivo. Motion contrast from blood flow is processed using the speckle variance OCT (svOCT) technique, which relies on the acquisition of multiple B-scan frames at the same location and tracking the change of the speckle pattern. Real-time mouse and human retinal imaging using two different custom-built OCT systems with processing and display performed on GPU are presented with an in-depth analysis of performance metrics. The display output included structural OCT data, en face projections of the intensity data, and the svOCT en face projections of retinal microvasculature; these results compare projections with and without speckle variance in the different retinal layers to reveal significant contrast improvements. As a demonstration, videos of real-time svOCT for in vivo human and mouse retinal imaging are included in our results. The capability of performing real-time svOCT imaging of the retinal vasculature may be a useful tool in a clinical environment for monitoring disease-related pathological changes in the microcirculation such as diabetic retinopathy.
Colour gamut enhancement with remote light conversion mechanism
NASA Astrophysics Data System (ADS)
Koseoglu, D.; Sezer, Y. S.; Karsli, K.
2018-01-01
The backlight unit spectrum of liquid crystal displays (LCD) directly affects the colour gamut. With the invention of GaN based blue light emitting diodes (LED), phosphors and quantum dots (QD) have gained considerable scientific interest due to their broad range of applications especially in lighting and display technologies. These phosphors and QDs are used to convert the blue light of the LEDs into white in general lighting. On the other hand, in display systems, they are used to generate red and green bands. There are different application methods such as on-chip and remote configurations. In this study, we concentrate on remote phosphor and QD backlight configurations where the light conversion is done away from the chips. In our display designs, we used GaN based blue LED lateral chips as an excitation source, on the other hand, light conversion layers were placed in backlight units as a thin film for the emission of green and red bands. The mixing ratios of these composite layers were arranged to match the emission spectrum of the blue LEDs and the light conversion layer to the colour filters of the LCD, so that the green, blue, and red bands efficiently widens the colour space. The results were also compared with the on-chip phosphor arrangements.
Modelling and Display of the Ultraviolet Sky
NASA Astrophysics Data System (ADS)
Daniels, J.; Henry, R.; Murthy, J.; Allen, M.; McGlynn, T. A.; Scollick, K.
1994-12-01
A computer program is currently under development to model in 3D - one dimension of which is wavelength - all the known and major speculated sources of ultraviolet (900 A - 3100 A ) radiation over the celestial sphere. The software is being written in Fortran 77 and IDL and currently operates under IRIX (the operating system of the Silicon Graphics Iris Machine); all output models are in FITS format. Models along with display software will become available to the astronomical community. The Ultraviolet Sky Model currently includes the Zodiacal Light, Point Sources of Emission, and the Diffuse Galactic Light. The Ultraviolet Sky Model is currently displayed using SkyView: a package under development at NASA/ GSFC, which allows users to retrieve and display publically available all-sky astronomical survey data (covering many wavebands) over the Internet. We present a demonstration of the SkyView display of the Ultraviolet Model. The modelling is a five year development project: the work illustrated here represents product output at the end of year one. Future work includes enhancements to the current models and incorporation of the following models: Galactic Molecular Hydrogen Fluorescence; Galactic Highly Ionized Atomic Line Emission; Integrated Extragalactic Light; and speculated sources in the intergalactic medium such as Ionized Plasma and radiation from Non-Baryonic Particle Decay. We also present a poster which summarizes the components of the Ultraviolet Sky Model and outlines a further package that will be used to display the Ultraviolet Model. This work is supported by United States Air Force Contract F19628-93-K-0004. Dr J. Daniels is supported with a post-doctoral Fellowship from the Leverhulme Foundation, London, United Kingdom. We are also grateful for the encouragement of Dr Stephen Price (Phillips Laboratory, Hanscomb Air Force Base, MA)
Designing low cost LED display for the billboard
NASA Astrophysics Data System (ADS)
Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng
2011-10-01
With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.
ERIC Educational Resources Information Center
Lee, Christopher S.; Todd, Neil P. McAngus
2004-01-01
The world's languages display important differences in their rhythmic organization; most particularly, different languages seem to privilege different phonological units (mora, syllable, or stress foot) as their basic rhythmic unit. There is now considerable evidence that such differences have important consequences for crucial aspects of language…
Animated Simulation: Determining Cost Effective Nurse Staffing for an Acute Care Unit
1997-06-19
Rate - Unscheduled Physician Visits Post- - Decubitus Ulcer Rate Discharge - Nosocomial Infection Rate (total) - Patient Knowledge of Disease...Condition - Nosocomial Urinary Tract Infection Rate and Care Requirements - Nosocomial Pneumonia Rate - Nosocomial Surgical Wound Infection Rate PROCESS...Nagaprasanna, 1988). A maternity unit at Bristol Hospital displayed dissatisfaction with their patient classification system. They found the patient
Ren, Guo-Jian; Chang, Ze; Xu, Jian; Hu, Zhenpeng; Liu, Yan-Qing; Xu, Yue-Ling; Bu, Xian-He
2016-02-04
A novel decorated metal-organic polyhedron (MOP) based metal-organic framework with a unique 4,9-connected network is successfully constructed, which displays a relatively strong interaction toward H2 and CO2 probably due to the existence of open metal sites in the secondary building units.
Forest statistics for Vermont: 1973 and 1983
Thomas S. Frieswyk; Anne M. Malley
1985-01-01
A statistical report on the fourth forest survey of Vermont conducted in 1982-1983 by the Forest Inventory and Analysis Unit, Northeastern Forest Experiment Station. Statistics for forest area, numbers of trees, timber volume, tree biomass, and timber products output are displayed at the state, unit, and county levels. The current inventory indicates that the state has...
Simulation and display of macromolecular complexes
NASA Technical Reports Server (NTRS)
Nir, S.; Garduno, R.; Rein, R.; Macelroy, R. D.
1977-01-01
In association with an investigation of the interaction of proteins with DNA and RNA, an interactive computer program for building, manipulating, and displaying macromolecular complexes has been designed. The system provides perspective, planar, and stereoscopic views on the computer terminal display, as well as views for standard and nonstandard observer locations. The molecule or its parts may be rotated and/or translated in any direction; bond connections may be added or removed by the viewer. Molecular fragments may be juxtaposed in such a way that given bonds are aligned, and given planes and points coincide. Another subroutine provides for the duplication of a given unit such as a DNA or amino-acid base.
The contribution of self-deceptive enhancement to display rules in the United States and Japan.
Chung, Joanne M
2012-03-01
Socially desirable responding was tested as a mediator of American and Japanese college student differences in display rules. Americans endorsed the expression of anger, contempt, disgust, fear, happiness, and surprise more than the Japanese. Americans also exhibited more self-deceptive enhancement than the Japanese, and self-deceptive enhancement partially mediated country differences on the endorsement of anger, disgust, happiness, and surprise, but not contempt and fear. These findings highlight the role of self-deceptive enhancement in contributing to expressive display rules and support the point of view that socially desirable responding is a reflection of one's personality and culture rather than a statistical nuisance.
Martínez-Silva, María de Lourdes; Imhoff-Manuel, Rebecca D; Sharma, Aarti; Heckman, CJ; Shneider, Neil A; Roselli, Francesco; Zytnicki, Daniel
2018-01-01
Hyperexcitability has been suggested to contribute to motoneuron degeneration in amyotrophic lateral sclerosis (ALS). If this is so, and given that the physiological type of a motor unit determines the relative susceptibility of its motoneuron in ALS, then one would expect the most vulnerable motoneurons to display the strongest hyperexcitability prior to their degeneration, whereas the less vulnerable should display a moderate hyperexcitability, if any. We tested this hypothesis in vivo in two unrelated ALS mouse models by correlating the electrical properties of motoneurons with their physiological types, identified based on their motor unit contractile properties. We found that, far from being hyperexcitable, the most vulnerable motoneurons become unable to fire repetitively despite the fact that their neuromuscular junctions were still functional. Disease markers confirm that this loss of function is an early sign of degeneration. Our results indicate that intrinsic hyperexcitability is unlikely to be the cause of motoneuron degeneration. PMID:29580378
An evaluation of the ELT-8 hematology analyzer.
Raik, E; McPherson, J; Barton, L; Hewitt, B S; Powell, E G; Gordon, S
1982-04-01
The TMELT-8 Hematology Analyzer is a fully automated cell counter which utilizes laser light scattering and hydrodynamic focusing to provide an 8 parameter whole blood count. The instrument consists of a sample handler with ticket printer, and a data handler with visual display unit, It accepts 100 microliter samples of venous or capillary blood and prints the values for WCC, RCC, Hb, Hct, MCV, MCH, MCHC and platelet count on to a standard result card. All operational and quality control functions, including graphic display of relative cell size distribution, can be obtained from the visual display unit and can also be printed as a permanent record if required. In a limited evaluation of the ELT-8, precision, linearity, accuracy, lack of sample carry-over and user acceptance were excellent. Reproducible values were obtained for all parameters after overnight storage of samples. Reagent usage and running costs were lower than for the Coulter S and the Coulter S Plus. The ease of processing capillary samples was considered to be a major advantage. The histograms served to alert the operator to a number of abnormalities, some of which were clinically significant.
Geology and geomorphology of the Carolina Sandhills, Chesterfield County, South Carolina
Swezey, Christopher; Fitzwater, Bradley A.; Whittecar, G. Richard
2016-01-01
This two-day field trip focuses on the geology and geomorphology of the Carolina Sandhills in Chesterfield County, South Carolina. This area is located in the updip portion of the U.S. Atlantic Coastal Plain province, supports an ecosystem of longleaf pine (Pinus palustris) and wiregrass (Aristida stricta), and contains three major geologic map units: (1) An ~60–120-m-thick unit of weakly consolidated sand, sandstone, mud, and gravel is mapped as the Upper Cretaceous Middendorf Formation and is interpreted as a fluvial deposit. This unit is capped by an unconformity, and displays reticulate mottling, plinthite, and other paleosol features at the unconformity. The Middendorf Formation is the largest aquifer in South Carolina. (2) A 0.3–10-m-thick unit of unconsolidated sand is mapped as the Quaternary Pinehurst Formation and is interpreted as deposits of eolian sand sheets and dunes derived via remobilization of sand from the underlying Cretaceous strata. This unit displays argillic horizons and abundant evidence of bioturbation by vegetation. (3) A <3-m-thick unit of sand, pebbly sand, sandy mud, and mud is mapped as Quaternary terrace deposits adjacent to modern drainages. In addition to the geologic units listed above, a prominent geomorphologic feature in the study area is a north-trending escarpment (incised by headwater streams) that forms a markedly asymmetric drainage divide. This drainage divide, as well as the Quaternary terraces deposits, are interpreted as evidence of landscape disequilibrium (possibly geomorphic responses to Quaternary climate changes).
NASA Technical Reports Server (NTRS)
Bleacher, Jacob E.; Crumpler, L. S.; Garry, W. B.; Zimbelman, J. R.; Self, S.; Aubele, J. C.
2012-01-01
Basaltic lavas typically form channels or tubes, which are recognized on the Earth and Mars. Although largely unrecognized in the planetary community, terrestrial inflated sheet flows also display morphologies that share many commonalities with lava plains on Mars. The McCartys lava flow field is among the youngest (approx.3000 yrs) basaltic flows in the continental United States. The southwest sections of the flow displays smooth, flat-topped plateaus with irregularly shaped pits and hummocky inter-plateau units that form a polygonal surface. Plateaus are typically elongate in map view, up to 20 m high and display lineations within the glassy crust. Lineated surfaces occasionally display small < 1m diameter lava coils. Lineations are generally straight and parallel each other, sometimes for over 100 meters. The boundaries between plateaus and depressions are also lineated and tilted to angles sometimes approaching vertical. Plateau-parallel cracks, sometimes containing squeeze-ups, mark the boundary between tilted crust and plateau. Some plateau depressions display level floors with hummocky surfaces, while some are bowl shaped with floors covered in broken lava slabs. The lower walls of pits sometimes display lateral, sagged lava wedges. Infrequently, pit floors display the upper portion of a tumulus from an older flow. In some places the surface crust has been disrupted forming a slabby texture. Slabs are typically on the scale of a meter or less across and no less than 7-10 cm thick. The slabs preserve the lineated textures of the undisturbed plateau crust. It appears that this style of terrain represents the emplacement of an extensive sheet that experiences inflation episodes within preferred regions where lateral spreading of the sheet is inhibited, thereby forming plateaus. Rough surfaces represent inflation-related disruption of pahoehoe lava and not a a lava. Depressions are often the result of non-inflation and can be clearly identified by lateral squeeze-outs along the pit walls that form when the rising crust exposes the still liquid core of the sheet. The plains of Tharsis and Elysium, Mars, display many analogous features
Dexter, Franklin; Willemsen-Dunlap, Ann; Lee, John D
2007-08-01
There are three basic types of decision aids to facilitate operating room (OR) management decision-making on the day of surgery. Decision makers can rely on passive status displays (e.g., big screens or whiteboards), active status displays (e.g., text pager notification), and/or command displays (e.g., text recommendations about what to do). Anesthesiologists, OR nurses, and housekeepers were given nine simulated scenarios (vignettes) involving multiple ORs to study their decision-making. Participants were randomized to one of four groups, all with an updated paper OR schedule: with/without command display and with/without passive status display. Participants making decisions without command displays performed no better than random chance in terms of increasing the predictability of work hours, reducing over-utilized OR time, and increasing OR efficiency. Status displays had no effect on these end-points, whereas command displays improved the quality of decisions. In the scenarios for which the command displays provided recommendations that adversely affected safety, participants appropriately ignored advice. Anesthesia providers and nursing staff made decisions that increased clinical work per unit time in each OR, even when doing so resulted in an increase in over-utilized OR time, higher staffing costs, unpredictable work hours, and/or mandatory overtime. Organizational culture and socialization during clinical training may be a cause. Command displays showed promise in mitigating this tendency. Additional investigations are in our companion paper.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... Required warning means the combination of one of the textual warning statements and its accompanying color... operates a facility where vending machines or self-service displays of cigarettes are permitted. United...
Does the availability of snack foods in supermarkets vary internationally?
Thornton, Lukar E; Cameron, Adrian J; McNaughton, Sarah A; Waterlander, Wilma E; Sodergren, Marita; Svastisalee, Chalida; Blanchard, Laurence; Liese, Angela D; Battersby, Sarah; Carter, Mary-Ann; Sheeshka, Judy; Kirkpatrick, Sharon I; Sherman, Sandy; Cowburn, Gill; Foster, Charlie; Crawford, David A
2013-05-14
Cross-country differences in dietary behaviours and obesity rates have been previously reported. Consumption of energy-dense snack foods and soft drinks are implicated as contributing to weight gain, however little is known about how the availability of these items within supermarkets varies internationally. This study assessed variations in the display of snack foods and soft drinks within a sample of supermarkets across eight countries. Within-store audits were used to evaluate and compare the availability of potato chips (crisps), chocolate, confectionery and soft drinks. Displays measured included shelf length and the proportion of checkouts and end-of-aisle displays containing these products. Audits were conducted in a convenience sample of 170 supermarkets across eight developed nations (Australia, Canada, Denmark, Netherlands, New Zealand, Sweden, United Kingdom (UK), and United States of America (US)). The mean total aisle length of snack foods (adjusted for store size) was greatest in supermarkets from the UK (56.4 m) and lowest in New Zealand (21.7 m). When assessed by individual item, the greatest aisle length devoted to chips, chocolate and confectionery was found in UK supermarkets while the greatest aisle length dedicated to soft drinks was in Australian supermarkets. Only stores from the Netherlands (41%) had less than 70% of checkouts featuring displays of snack foods or soft drinks. Whilst between-country variations were observed, overall results indicate high levels of snack food and soft drinks displays within supermarkets across the eight countries. Exposure to snack foods is largely unavoidable within supermarkets, increasing the likelihood of purchases and particularly those made impulsively.
Does the availability of snack foods in supermarkets vary internationally?
2013-01-01
Background Cross-country differences in dietary behaviours and obesity rates have been previously reported. Consumption of energy-dense snack foods and soft drinks are implicated as contributing to weight gain, however little is known about how the availability of these items within supermarkets varies internationally. This study assessed variations in the display of snack foods and soft drinks within a sample of supermarkets across eight countries. Methods Within-store audits were used to evaluate and compare the availability of potato chips (crisps), chocolate, confectionery and soft drinks. Displays measured included shelf length and the proportion of checkouts and end-of-aisle displays containing these products. Audits were conducted in a convenience sample of 170 supermarkets across eight developed nations (Australia, Canada, Denmark, Netherlands, New Zealand, Sweden, United Kingdom (UK), and United States of America (US)). Results The mean total aisle length of snack foods (adjusted for store size) was greatest in supermarkets from the UK (56.4 m) and lowest in New Zealand (21.7 m). When assessed by individual item, the greatest aisle length devoted to chips, chocolate and confectionery was found in UK supermarkets while the greatest aisle length dedicated to soft drinks was in Australian supermarkets. Only stores from the Netherlands (41%) had less than 70% of checkouts featuring displays of snack foods or soft drinks. Conclusion Whilst between-country variations were observed, overall results indicate high levels of snack food and soft drinks displays within supermarkets across the eight countries. Exposure to snack foods is largely unavoidable within supermarkets, increasing the likelihood of purchases and particularly those made impulsively. PMID:23672409
Displays of emotion and citizen support for Merkel and Gysi.
Gabriel, Oscar W; Masch, Lena
2017-01-01
Emotional appeals have always been an important instrument in the mobilization of political support in modern societies. As found in several experimental studies from the United States, the emotions displayed by leading politicians in their televised public appearances have an impact on the political attitudes and behaviors of the public. Positive emotions such as joy or happiness, pride, and amusement elicit a more positive assessment of politicians, whereas showing negative emotions such as anger or outrage often diminishes the public's support. This transfer of emotions from sender to recipient has been described as "emotional contagion." However, under specific circumstances, emotions expressed by politicians can result in counter-empathic reactions among recipients. To examine the role of emotions between political leaders and the public in an institutional and cultural setting outside the United States, this article presents experimental findings on the impact of emotions expressed by two leading German politicians on the German public. The study used emotional displays by Chancellor Angela Merkel and former parliamentary leader of the Left Party, Gregor Gysi, observing how their assessments by the German public changed in response to these displays. Consistent with existing research, we discovered positive effects on the evaluation of both politicians when they displayed positive emotions. However, the impact of negative emotions is different for Merkel and Gysi and can be described as contagion in the former and counter-contagion in the latter case. Furthermore, we found that individual recognition of the expressed emotions modified the effect they had on the evaluation of some leadership characteristics.
Robert E. Vihnanek; Cameron S. Balog; Clinton S. Wright; Roger D. Ottmar; Jeffrey W. Kelly
2009-01-01
Two series of single and stereo photographs display a range of natural conditions and fuel loadings in post-hurricane forests in the southeastern United States. Each group of photos includes inventory information summarizing vegetation composition, structure and loading, woody material loading and density by size class, forest floor loading, and various site...
Mark Nelson; Greg Liknes; Charles H. Perry
2009-01-01
Analysis and display of forest composition, structure, and pattern provides information for a variety of assessments and management decision support. The objective of this study was to produce geospatial datasets and maps of conterminous United States forest land ownership, forest site productivity, timberland, and reserved forest land. Satellite image-based maps of...
ERIC Educational Resources Information Center
Carr, Linda
This learning unit on using graphs is one in the Choice Series, a self-learning development program for supervisors. Purpose stated for the approximately eight-hour-long unit is to enable the supervisor to look at the usefulness of graphs in displaying figures, use graphs to compare sets of figures, identify trends and seasonal variations in…
An Assessment of the Red Maple Resource in the Northeastern United States
Delton R., Jr. Alderman; Matthew S. Bumgardner; John E. Baumgras; John E. Baumgras
2005-01-01
The red maple resource in the northeastern United States has exhibited dramatic gains in the past 3 decades in terms of stem numbers and net volume. Growing stock and sawtimber volumes have displayed extraordinary growth compared to other species, and red maple is replacing important market species that have historically been used in the Northeast. The increase in red...
ERIC Educational Resources Information Center
Samson, Frank L.
2013-01-01
This study identifies a theoretical mechanism that could potentially affect public university admissions standards in a context of demographic change. I explore how demographic changes at a prestigious public university in the United States affect individuals' evaluations of college applications. Responding to a line graph that randomly displays a…
Features and limitations of mobile tablet devices for viewing radiological images.
Grunert, J H
2015-03-01
Mobile radiological image display systems are becoming increasingly common, necessitating a comparison of the features of these systems, specifically the operating system employed, connection to stationary PACS, data security and rang of image display and image analysis functions. In the fall of 2013, a total of 17 PACS suppliers were surveyed regarding the technical features of 18 mobile radiological image display systems using a standardized questionnaire. The study also examined to what extent the technical specifications of the mobile image display systems satisfy the provisions of the Germany Medical Devices Act as well as the provisions of the German X-ray ordinance (RöV). There are clear differences in terms of how the mobile systems connected to the stationary PACS. Web-based solutions allow the mobile image display systems to function independently of their operating systems. The examined systems differed very little in terms of image display and image analysis functions. Mobile image display systems complement stationary PACS and can be used to view images. The impacts of the new quality assurance guidelines (QS-RL) as well as the upcoming new standard DIN 6868 - 157 on the acceptance testing of mobile image display units for the purpose of image evaluation are discussed. © Georg Thieme Verlag KG Stuttgart · New York.
Dual-Use Applications of Infrared Sensitive Materials: Appendices
1993-06-01
CLUs. The Command Launch Unit and missile round each use a second generation forward looking IR detector. The CLU uses a LWIR , MCT-based, 240xI scanning...read out digitally to other display units or video equipment through a port on the unit’s side. The IR detector in the CLU operates in the LWIR for two...greater than about a kilometer needs to operate generally in the LWIR to achieve the sensitivity necessary to image objects at those distances.’ Second
Head-Up Display (HUD) Technology Demonstration.
1983-07-01
changrd, if you wish to be removed from our mailing list, or if the addressee is no longer employed by your organization please notify AFWAL/AA T, W-PAFB...S. E. Shields ’ 9. PERFORMING ORGANIZATION NAME ANO ADORESS 10. PROGRAM LEMENT. PROJECT TASK Display Technology Staff AREA P O ORK UNIT N.UME.RS...stains, it did indicate that the stains contained organic structures that could not be explained by exposure to atmosphere. The results of the surface
Performance and Preference with Various VDT (Video Display Terminal) Phosphors
1987-04-24
Unit M\\100.001-1302. was submitted for review on 13 March 1987, approved for publication on 24 April 1987, and has been designated as Naval Submarine... designed to investigate reading fatigue, Nordqvist et al. (1986) had their subjects read texts for 15 minutes, followed by 5 minutes of performance tests...Doc, Ophthalmol. 3: 138-163. Tu-lis, T.S. (1981). An evaluation of alphanumeric, graphic , and color information displays. -_pman Factors 23: 541-550
NASA Astrophysics Data System (ADS)
Fiorentini, M. L.; Rosengren, N.; Beresford, S. W.; Grguric, B.; Barley, M. E.
2007-11-01
The Mount Keith (MKD5) nickel sulfide deposit is one of the largest komatiite-hosted nickel sulfide deposits in the world; it is hosted by a distinctive spinifex-free, cumulate-rich, ultramafic horizon/unit termed the Mount Keith Ultramafic (MKU). The Mount Keith Ultramafic shows significant variation along its lateral extent. The internal architecture is made up of adcumulate-textured pods and lenses, which are flanked by thinner meso- and orthocumulate-textured units, overlain by pyroxenitic and gabbroic horizons. The lateral and vertical changes in the geometry and internal architecture reflect variations in the lithological association and emplacement conditions along the strike extent of the belt. The chilled margins of the Mount Keith Ultramafic unit contain ˜1,200 ppm Ni. Olivine cumulates average ˜2,500 3,500 ppm Ni, with few exceptions (Ni > 4,500 ppm) reflecting occurrence of minor nickel sulfides, whereas pyroxenites and gabbros generally contain, respectively, ˜1,500 2,000 and ˜100 1,000 ppm Ni. Olivine cumulates generally contain low Cr concentrations (<2,500 ppm Cr), with the rare presence of chromite-rich intervals containing anomalously high values (>5,000 ppm Cr). The internal stratigraphy of the Mount Keith Ultramafic unit may be subdivided into two groups based on rare earth element distribution. The chilled margins and the internal units of the Main Adcumulate domain display LREE-enriched patterns [(La/Sm) n > 1 3] and negative Eu, Hf, Zr, Nb, and Ti anomalies. The internal units in the Western Mineralized Zone generally display flat chondrite-normalized REE patterns and only minor negative Nb anomalies. The pattern of platinum-group element (PGE) distribution varies greatly along the strike extent of the Mount Keith Ultramafic unit. The chilled margins display relatively low absolute concentrations [PGE (excl. Os) ˜16 ppb] and relatively fractionated patterns, with subchondritic Pt/Pd ratios (˜1.5), and superchondritic Pd/Ir ratios (˜3). The PGE trends in the thick adcumulate-textured pods containing widespread nickel sulfide mineralization display positive correlation with sulfide abundance, whereas fractionated pyroxenites and gabbros in the thinner domains display highly depleted PGE concentrations and generally show compatible PGE trends. The nickel sulfide ore typology and style vary greatly along the strike extension of the Mount Keith Ultramafic unit. Basal massive nickel sulfide mineralization (e.g., Sarah’s Find) occurs in the thinner meso- and orthocumulate-textured units, whereas stratabound disseminated nickel sulfide mineralization (e.g., MKD5 Ni Deposit) is hosted in the adcumulate-textured pods. We hypothesize that the very low PGE content of the initial liquid of the Mount Keith Ultramafic unit indicates that the initial magma pulse that penetrated through the dacite host-rock had already equilibrated with sulfides at depth and/or carried entrained immiscible sulfide blebs. We argue that upon emplacement, the intruding magma experienced a significant thermal shock at the contact with water-saturated volcaniclastic breccias. The sudden chilling would have increased the viscosity of the magma, possibly to the point where it was no longer able to sustain the suspension of the immiscible sulfide liquid. As a result, the sulfide blebs coalesced and formed the basal massive sulfide nickel sulfide mineralization at the base of the sill (i.e., Sarah’s Find). Prolonged focused high volume magma flow within the sill resulted in the emplacement of a thick, lens-shaped accumulation of olivine adcumulate. Local variations in intensive parameters other than crustal assimilation (e.g., T, fO2, fS2) may be principally responsible for sulfide supersaturation and controlled the local distribution of stratabound disseminated nickel sulfide mineralization (e.g., MKD5 Ni Deposit), generally localized within the core of the thicker dunite lenses.
Yeast cell surface display for lipase whole cell catalyst and its applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yun; Zhang, Rui; Lian, Zhongshuai
The cell surface display technique allows for the expression of target proteins or peptides on the microbial cell surface by fusing an appropriate protein as an anchoring motif. Yeast display systems, such as Pichia pastoris, Yarowia lipolytica and Saccharomyces cerevisiae, are ideal, alternative and extensive display systems with the advantage of simple genetic manipulation and post-translational modification of expressed heterologous proteins. Engineered yeasts show high performance characteristics and variant utilizations. Herein, we comprehensively summarize the variant factors affecting lipase whole cell catalyst activity and display efficiency, including the structure and size of target proteins, screening anchor proteins, type and chainmore » length of linkers, and the appropriate matching rules among the above-mentioned display units. Furthermore, we also address novel approaches to enhance stability and activity of recombinant lipases, such as VHb gene co-expression, multi-enzyme co-display technique, and the micro-environmental interference and self-assembly techniques. Finally, we represent the variety of applications of whole cell surface displayed lipases on yeast cells in non-aqueous phases, including synthesis of esters, PUFA enrichment, resolution of chiral drugs, organic synthesis and biofuels. We demonstrate that the lipase surface display technique is a powerful tool for functionalizing yeasts to serve as whole cell catalysts, and increasing interest is providing an impetus for broad application of this technique.« less
Study of a direct visualization display tool for space applications
NASA Astrophysics Data System (ADS)
Pereira do Carmo, J.; Gordo, P. R.; Martins, M.; Rodrigues, F.; Teodoro, P.
2017-11-01
The study of a Direct Visualization Display Tool (DVDT) for space applications is reported. The review of novel technologies for a compact display tool is described. Several applications for this tool have been identified with the support of ESA astronauts and are presented. A baseline design is proposed. It consists mainly of OLEDs as image source; a specially designed optical prism as relay optics; a Personal Digital Assistant (PDA), with data acquisition card, as control unit; and voice control and simplified keyboard as interfaces. Optical analysis and the final estimated performance are reported. The system is able to display information (text, pictures or/and video) with SVGA resolution directly to the astronaut using a Field of View (FOV) of 20x14.5 degrees. The image delivery system is a monocular Head Mounted Display (HMD) that weights less than 100g. The HMD optical system has an eye pupil of 7mm and an eye relief distance of 30mm.
NASA Technical Reports Server (NTRS)
Easley, W. C.; Tanguy, J. S.
1986-01-01
An upgrade of the transport systems research vehicle (TSRV) experimental flight system retained the original monochrome display system. The original host computer was replaced with a Norden 11/70, a new digital autonomous terminal access communication (DATAC) data bus was installed for data transfer between display system and host, while a new data interface method was required. The new display data interface uses four split phase bipolar (SPBP) serial busses. The DATAC bus uses a shared interface ram (SIR) for intermediate storage of its data transfer. A display interface unit (DIU) was designed and configured to read from and write to the SIR to properly convert the data from parallel to SPBP serial and vice versa. It is found that separation of data for use by each SPBP bus and synchronization of data tranfer throughout the entire experimental flight system are major problems which require solution in DIU design. The techniques used to accomplish these new data interface requirements are described.
Eadie, Douglas; Stead, Martine; MacKintosh, Anne Marie; Murray, Susan; Best, Catherine; Pearce, Jamie; Tisch, Catherine; van der Sluijs, Winfried; Amos, Amanda; MacGregor, Andy; Haw, Sally
2016-01-01
Background From April 6th 2015, all small shops in the UK were required to cover up tobacco products at point of sale (POS) to protect children from exposure. As part of a larger 5-year study to measure the impact of the legislation in Scotland, an audit was conducted to assess level and nature of compliance with the ban immediately following its introduction. Materials and Methods A discreet observational audit was conducted 7–14 days post implementation which took measures of physical changes made to cover products, server/assistant practices, tobacco signage and advertising, and communication of price information. The audit was conducted in all small retail outlets (n = 83) selling tobacco in four communities in Scotland selected to represent different levels of urbanisation and social deprivation. Data were analysed descriptively. Results Compliance with the legislation was high, with 98% of shops removing tobacco from permanent display and non-compliance was restricted almost entirely to minor contraventions. The refurbishment of shops with new or adapted tobacco storage units resulted in the removal of nearly all commercial brand messages and images from POS, dropping from 51% to 4%. The majority of shops stored their tobacco in public-facing storage units (81%). Most shops also displayed at least one generic tobacco message (88%). Conclusions Compliance with Scottish prohibitions on display of tobacco products in small retail outlets was high immediately after the legislation implementation date. However, although tobacco branding is no longer visible in retail outlets, tobacco storage units with generic tobacco messages are still prominent. This points towards a need to monitor how the space vacated by tobacco products is utilised and to better understand how the continuing presence of tobacco storage units influences people’s awareness and understanding of tobacco and smoking. Countries with existing POS bans and who are considering such bans should pay particular attention to regulations regarding the use of generic signage and where within the retail setting tobacco stocks can be stored. PMID:27019418
Eadie, Douglas; Stead, Martine; MacKintosh, Anne Marie; Murray, Susan; Best, Catherine; Pearce, Jamie; Tisch, Catherine; van der Sluijs, Winfried; Amos, Amanda; MacGregor, Andy; Haw, Sally
2016-01-01
From April 6th 2015, all small shops in the UK were required to cover up tobacco products at point of sale (POS) to protect children from exposure. As part of a larger 5-year study to measure the impact of the legislation in Scotland, an audit was conducted to assess level and nature of compliance with the ban immediately following its introduction. A discreet observational audit was conducted 7-14 days post implementation which took measures of physical changes made to cover products, server/assistant practices, tobacco signage and advertising, and communication of price information. The audit was conducted in all small retail outlets (n = 83) selling tobacco in four communities in Scotland selected to represent different levels of urbanisation and social deprivation. Data were analysed descriptively. Compliance with the legislation was high, with 98% of shops removing tobacco from permanent display and non-compliance was restricted almost entirely to minor contraventions. The refurbishment of shops with new or adapted tobacco storage units resulted in the removal of nearly all commercial brand messages and images from POS, dropping from 51% to 4%. The majority of shops stored their tobacco in public-facing storage units (81%). Most shops also displayed at least one generic tobacco message (88%). Compliance with Scottish prohibitions on display of tobacco products in small retail outlets was high immediately after the legislation implementation date. However, although tobacco branding is no longer visible in retail outlets, tobacco storage units with generic tobacco messages are still prominent. This points towards a need to monitor how the space vacated by tobacco products is utilised and to better understand how the continuing presence of tobacco storage units influences people's awareness and understanding of tobacco and smoking. Countries with existing POS bans and who are considering such bans should pay particular attention to regulations regarding the use of generic signage and where within the retail setting tobacco stocks can be stored.
NASA Astrophysics Data System (ADS)
Chun, Won-Suk; Napoli, Joshua; Cossairt, Oliver S.; Dorval, Rick K.; Hall, Deirdre M.; Purtell, Thomas J., II; Schooler, James F.; Banker, Yigal; Favalora, Gregg E.
2005-03-01
We present a software and hardware foundation to enable the rapid adoption of 3-D displays. Different 3-D displays - such as multiplanar, multiview, and electroholographic displays - naturally require different rendering methods. The adoption of these displays in the marketplace will be accelerated by a common software framework. The authors designed the SpatialGL API, a new rendering framework that unifies these display methods under one interface. SpatialGL enables complementary visualization assets to coexist through a uniform infrastructure. Also, SpatialGL supports legacy interfaces such as the OpenGL API. The authors" first implementation of SpatialGL uses multiview and multislice rendering algorithms to exploit the performance of modern graphics processing units (GPUs) to enable real-time visualization of 3-D graphics from medical imaging, oil & gas exploration, and homeland security. At the time of writing, SpatialGL runs on COTS workstations (both Windows and Linux) and on Actuality"s high-performance embedded computational engine that couples an NVIDIA GeForce 6800 Ultra GPU, an AMD Athlon 64 processor, and a proprietary, high-speed, programmable volumetric frame buffer that interfaces to a 1024 x 768 x 3 digital projector. Progress is illustrated using an off-the-shelf multiview display, Actuality"s multiplanar Perspecta Spatial 3D System, and an experimental multiview display. The experimental display is a quasi-holographic view-sequential system that generates aerial imagery measuring 30 mm x 25 mm x 25 mm, providing 198 horizontal views.
Large Terrain Continuous Level of Detail 3D Visualization Tool
NASA Technical Reports Server (NTRS)
Myint, Steven; Jain, Abhinandan
2012-01-01
This software solved the problem of displaying terrains that are usually too large to be displayed on standard workstations in real time. The software can visualize terrain data sets composed of billions of vertices, and can display these data sets at greater than 30 frames per second. The Large Terrain Continuous Level of Detail 3D Visualization Tool allows large terrains, which can be composed of billions of vertices, to be visualized in real time. It utilizes a continuous level of detail technique called clipmapping to support this. It offloads much of the work involved in breaking up the terrain into levels of details onto the GPU (graphics processing unit) for faster processing.
Study of cryogenic propellant systems for loading the space shuttle
NASA Technical Reports Server (NTRS)
Voth, R. O.; Steward, W. G.; Hall, W. J.
1974-01-01
Computer programs were written to model the liquid oxygen loading system for the space shuttle. The programs allow selection of input data through graphic displays which schematically depict the part of the system being modeled. The computed output is also displayed in the form of graphs and printed messages. Any one of six computation options may be selected. The first four of these pertain to thermal stresses, pressure surges, cooldown times, flow rates and pressures during cooldown. Options five and six deal with possible water hammer effects due to closing of valves, steady flow and transient response to changes in operating conditions after cooldown. Procedures are given for operation of the graphic display unit and minicomputer.
The contribution of self-deceptive enhancement to display rules in the United States and Japan
Chung, Joanne M.
2012-01-01
Socially desirable responding was tested as a mediator of American and Japanese college student differences in display rules. Americans endorsed the expression of anger, contempt, disgust, fear, happiness, and surprise more than the Japanese. Americans also exhibited more self-deceptive enhancement than the Japanese, and self-deceptive enhancement partially mediated country differences on the endorsement of anger, disgust, happiness, and surprise, but not contempt and fear. These findings highlight the role of self-deceptive enhancement in contributing to expressive display rules and support the point of view that socially desirable responding is a reflection of one’s personality and culture rather than a statistical nuisance. PMID:25400501
Brian Sullivan; Nadir Erbilgin
2014-01-01
Roptrocerus xylophagorum (Ratzeburg) (Hymenoptera: Pteromalidae) is a common Holarctic parasitoid of the larvae and pupae of bark beetles (Coleoptera: Curculionidae: Scotytinae). In no-choice laboratory bioassays, we found that male wasps derived either from northern California or southwestern Mississippi, United States of America more frequently displayed sexual...
The United States’ Role in Combating Militant Islam in France
2011-03-16
United States Army DISTRIBUTION STATEMENT A : Approved for Public Release. Distribution is Unlimited. This SRP is submitted in partial...provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently...SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION / AVAILABILITY STATEMENT Distribution A : Unlimited 13. SUPPLEMENTARY NOTES
ERIC Educational Resources Information Center
Pumper, Megan A.; Yaeger, Jeffery P.; Moreno, Megan A.
2013-01-01
Social networking sites are globally popular. In the United States, these types of sites are perceived positively by users and used at high rates, which has likely yielded personal health behavior displays such as substance abuse and depression. Due to possible cultural influence present on these sites, it remains unknown if SNS could be utilized…
Profiles of gamma-ray and magnetic data from aerial surveys over the conterminous United States
Duval, Joseph S.; Riggle, Frederic E.
1999-01-01
This publication contains images for the conterminous U.S. generated from geophysical data, software for displaying and analyzing the images, and software for displaying and examining the profile data from the aerial surveys flown as part of the National Uranium Resource Evaluation (NURE) Program of the U.S. Department of Energy. The images included are of gamma-ray data (uranium, thorium, and potassium channels), Bouguer gravity data, isostatic residual gravity data, aeromagnetic anomalies, topography, and topography with bathymetry.
1987-02-01
Factors Laboratory, Department of Industria AREA 6 WORK UNIT NUAE1 Engineering and Operations Research, Virginia Pol - technic Institute & State Univ...Symbolic Research 105 Experiment 14: Multichromatic Optimum Character Symbolic 105 Summary 105 Quality Metrics Analysis 105 REFERENCES 107 ANNOTATED...17.52 12.26 9.43 7.66 6.45 5.57 An analysis of variance was performed on accuracy and response time data. For accuracy data there was a significant
3D Visualization of an Invariant Display Strategy for Hyperspectral Imagery
2002-12-01
to Remote Sensing, New York, New York: Guillford Press, March 2002. Deitel , H. M., Deitel , P. J., Nieto, T. R. and Lin, T. M., XML How to Program ...Principal Component Analysis (PCA) to rotate the data into a coordinate space, which can be used to display the data. This thesis demonstrates how to ...radiation band is the natural unit of data organization, the BSQ format is also easy to implement. Figure 2.5 shows how a scene originally sensed
LMDS Lightweight Modular Display System.
1982-02-16
based on standard functions. This means that the cost to produce a particular display function can be met in the most economical fashion and at the same...not mean that the NTDS interface would be eliminated. What is anticipated is the use of ETHERNET at a low level of system interface, ie internal to...GENERATOR dSYMBOL GEN eCOMMUNICATION 3-2 The architecture of the unit’s (fig 3-4) input circuitry is based on a video table look-up ROM. The function
Mapping protein-protein interactions with phage-displayed combinatorial peptide libraries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kay, B. K.; Castagnoli, L.; Biosciences Division
This unit describes the process and analysis of affinity selecting bacteriophage M13 from libraries displaying combinatorial peptides fused to either a minor or major capsid protein. Direct affinity selection uses target protein bound to a microtiter plate followed by purification of selected phage by ELISA. Alternatively, there is a bead-based affinity selection method. These methods allow one to readily isolate peptide ligands that bind to a protein target of interest and use the consensus sequence to search proteomic databases for putative interacting proteins.
Computer-Aided Design and Manufacturing for Closed-Die Forging of Track Shoes and Links
1976-07-01
file. VII-39 CALL RESTRI(TAG) Restores a blanked item. CALL SCROLG( NLINES ,IYTOP) To adjust scroller parameters. Graphics Monitor must be in use... NLINES : Number of lines to be displayed. IYTOP: Y-coordinate of the top line. Each line is 25 units vertical. CALL TRACK To enable the tracking...5. NLINES - The number of lines reserved for the text scroller area when text is displayed along with graphic images. 6. AL - The vertical
Atmospheric Science Data Center
2013-04-17
... Terrain Elevation Model from the United States Geological Survey. It is displayed in an equidistant conic projection. The image area ... MD. The MISR data were obtained from the NASA Langley Research Center Atmospheric Science Data Center in Hampton, VA. Image ...
User Friendly Real Time Display
NASA Astrophysics Data System (ADS)
McCarthy, Denise M.; McCracken, Bill
1989-02-01
Real-time viewing of high resolution infrared line scan reconnaissance imagery is greatly facilitated using Honeywell's Real Time Display in conjunction with a D-500 Infrared Reconnaissance System. The Real-Time Display (RTD) provides the capability of on-board review of high resolution infrared imagery using the wide infrared dynamic range of the D-500 infrared receiver to maximum advantage. The scan converter accepts, processes, and displays imagery from four channels of the IR Receiver after formatting by a multiplexer. The scan converter interfaces with a standard RS-170 video monitor. Detailed review and on-board analysis of infrared reconnaissance imagery stored on a videotape is easily accomplished using the many user-friendly features of the RTD. Using a convenient joystick controller, on-screen mode menus, and a moveable cursor, the operator can examine scenes of interest at four different display magnifications using a four step bidirectional zoom. Imagery areas of interest are first noted using the scrolling wide field display mode at 8x reduced display resolution. On noting an area of interest, the imagery can be marked on the tape record for future recovery and a freeze frame mode can be initiated. The operator can then move the cursor to the area of interest and zoom to higher display magnification for 4x, 2x, and lx display resolutions so that the full 4096 x 4096 pixel infrared frame can be matched to the 512 x 512 pixel display frame. At 8x wide field display magnification the full line scanner field of view is displayed at 8x reduced resolution. There are two selectable modes of obtaining this reduced resolution. The operator can use the default method, which averages the signal from an 8 x 8 pixel group, or it is also possible to select the peak signal of the 8 x 8 pixel block to represent the entire block on the display. In this alternate peak-signal display the wide field can be effectively scanned for hot objects which are more likely to be candidate targets. The intermediate 4x and 2x zoom steps are very useful in maintaining operator orientation in examining target clusters and industrial complexes. The four operating modes of the RTD are described and their use to the operator on a typical mission is outlined. Some installation details are given. The RTD as part of a complete D-500 Infrared Linescan Reconnaissance System is now being installed on a Beech 1900 Environmental Control Aircraft to monitor pollution in very sensitive and commercially important marine ecologies. Its application on military reconnaissance missions will allow the normal review of recorded videotape imagery at a ground station immediately after return of the aircraft to base. The areas of highest interest will have been previously marked during the airborne real-time review by the operator. The RTD packages into only two Line Replaceable Units (LRUs), a Scan Converter, and a Control Unit which includes a joystick hand controller. The CRT display is assumed to be part of the aircraft.
Scream-embrace displays in wild black-horned capuchin monkeys.
Lynch Alfaro, Jessica
2008-06-01
Reintroduction of capuchin monkeys (Cebus apella) into their social group in captivity can elicit sirena screams and embraces. Captive scream-embrace displays are male biased, and females never perform sirena screams. One hypothesis is that scream-embrace displays serve a tension-reduction or reconciliatory function between males with conflicting interests. Alternatively, these displays may function to maintain strong affiliative bonds between friendly male dyads. Scream and/or embrace displays in wild Brazilian black-horned capuchins were analyzed for social and ecological contexts, behavioral components, and individuals involved. Seventy-two displays were observed during the 199-day study period. Among the 66 displays for which both members could be identified by sex, there were 42 occurrences of male-male dyads, 17 of male-female dyads, and seven of female-female dyads. Scream-embrace dyads were male-male pairs significantly more often than expected from group membership, and the alpha male was the only male to engage in scream-embrace displays with females. Female-female pairs did embrace, but never emitted sirena screams. Displays most commonly occurred in "reunion" contexts, primarily the reuniting of subgroups after hours or days out of contact, but also after intergroup encounters, and across groups in "intergroup" displays. Displays were rare, but socially contagious, and subgroup reunions could elicit multiple displays in rapid succession. Although the occurrence of screams and embraces was positively correlated, both behaviors also occurred independently, and their functions may be different. Male sirena screams may be honest advertisements of united alliances, directed toward a third party, whereas the embrace may be a risky affiliative signal, directed primarily within the dyad. Copyright 2008 Wiley-Liss, Inc.
Method and Apparatus for Improved Spatial Light Modulation
NASA Technical Reports Server (NTRS)
Soutar, Colin (Inventor); Juday, Richard D. (Inventor)
2000-01-01
A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain the optical processing objective.
Method and Apparatus for Improved Spatial Light Modulation
NASA Technical Reports Server (NTRS)
Colin, Soutar (Inventor); Juday, Richard D. (Inventor)
1999-01-01
A method and apparatus for modulating a light beam in an optical processing system is described. Preferably, an electrically-controlled polarizer unit and/or an analyzer unit are utilized in combination with a spatial light modulator and a controller. Preferably, the spatial light modulator comprises a pixelated birefringent medium such as a liquid crystal video display. The combination of the electrically controlled polarizer unit and analyzer unit make it simple and fast to reconfigure the modulation described by the Jones matrix of the spatial light modulator. A particular optical processing objective is provided to the controller. The controller performs calculations and supplies control signals to the polarizer unit, the analyzer unit, and the spatial light modulator in order to obtain die optical processing objective.
Virtual Reality Used to Serve the Glenn Engineering Community
NASA Technical Reports Server (NTRS)
Carney, Dorothy V.
2001-01-01
There are a variety of innovative new visualization tools available to scientists and engineers for the display and analysis of their models. At the NASA Glenn Research Center, we have an ImmersaDesk, a large, single-panel, semi-immersive display device. This versatile unit can interactively display three-dimensional images in visual stereo. Our challenge is to make this virtual reality platform accessible and useful to researchers. An example of a successful application of this computer technology is the display of blade out simulations. NASA Glenn structural dynamicists, Dr. Kelly Carney and Dr. Charles Lawrence, funded by the Ultra Safe Propulsion Project under Base R&T, are researching blade outs, when turbine engines lose a fan blade during operation. Key objectives of this research include minimizing danger to the aircraft via effective blade containment, predicting destructive loads due to the imbalance following a blade loss, and identifying safe, cost-effective designs and materials for future engines.
Situational Lightning Climatologies for Central Florida: Phase III
NASA Technical Reports Server (NTRS)
Barrett, Joe H., III
2008-01-01
This report describes work done by the Applied Meteorology Unit (AMU) to add composite soundings to the Advanced Weather Interactive Processing System (AWIPS). This allows National Weather Service (NWS) forecasters to compare the current atmospheric state with climatology. In a previous phase, the AMU created composite soundings for four rawinsonde observation stations in Florida, for each of eight flow regimes. The composite soundings were delivered to the NWS Melbourne (MLB) office for display using the NSHARP software program. NWS MLB requested that the AMU make the composite soundings available for display in AWIPS. The AMU first created a procedure to customize AWIPS so composite soundings could be displayed. A unique four-character identifier was created for each of the 32 composite soundings. The AMU wrote a Tool Command Language/Tool Kit (TcVTk) software program to convert the composite soundings from NSHARP to Network Common Data Form (NetCDF) format. The NetCDF files were then displayable by AWIPS.
Specific ligands for classical swine fever virus screened from landscape phage display library.
Yin, Long; Luo, Yuzi; Liang, Bo; Wang, Fei; Du, Min; Petrenko, Valery A; Qiu, Hua-Ji; Liu, Aihua
2014-09-01
Classical swine fever (CSF) is a devastating infectious disease caused by classical swine fever virus (CSFV). The screening of CSFV-specific ligands is of great significance for diagnosis and treatment of CSF. Affinity selection from random peptide libraries is an efficient approach to discover ligands with high stability and specificity. Here, we screened phage ligands for the CSFV E2 protein from f8/8 landscape phage display library by biopanning and obtained four phage clones specific for the E2 protein of CSFV. Viral blocking assays indicated that the phage clone displaying the octapeptide sequence DRATSSNA remarkably inhibited the CSFV replication in PK-15 cells at a titer of 10(10) transduction units, as evidenced by significantly decreased viral RNA copies and viral titers. The phage-displayed E2-binding peptides have the potential to be developed as antivirals for CSF. Copyright © 2014 Elsevier B.V. All rights reserved.
Human factors of intelligent computer aided display design
NASA Technical Reports Server (NTRS)
Hunt, R. M.
1985-01-01
Design concepts for a decision support system being studied at NASA Langley as an aid to visual display unit (VDU) designers are described. Ideally, human factors should be taken into account by VDU designers. In reality, although the human factors database on VDUs is small, such systems must be constantly developed. Human factors are therefore a secondary consideration. An expert system will thus serve mainly in an advisory capacity. Functions can include facilitating the design process by shortening the time to generate and alter drawings, enhancing the capability of breaking design requirements down into simpler functions, and providing visual displays equivalent to the final product. The VDU system could also discriminate, and display the difference, between designer decisions and machine inferences. The system could also aid in analyzing the effects of designer choices on future options and in ennunciating when there are data available on a design selections.
Rogers, Jennifer D; Ajami, Nadim J; Fryszczyn, Bartlomiej G; Estes, Mary K; Atmar, Robert L; Palzkill, Timothy
2013-06-01
Norovirus (NoV) is the most common agent of nonbacterial epidemic gastroenteritis and is estimated to cause 21 million cases of the disease in the United States annually. The antigen enzyme-linked immunosorbent assays (ELISAs) currently available for NoV diagnosis detect only certain strains and are approved for use in the United States only in epidemics where NoV is suspected. There is a clear need for simpler, more rapid, and more reliable diagnostic tools for the detection of NoV. In this study, phage display technology was used to screen a library of phage displaying random 12-mer peptides for those that bind to Norwalk virus virus-like particles (NV VLPs). Three phage clones displaying unique peptides were identified, and both the peptide-displaying phages and the peptides were confirmed to bind specifically to NV VLPs. The peptide displayed on phage clone NV-N-R5-1 was determined to bind to the protruding domain of the VP1 capsid protein. This phage also bound to NV VLPs seeded into NoV-negative stool with a limit of detection of 1.56 ng NV VLP. This value was comparable to monoclonal antibody (MAb) 3912, which is currently used in commercially available assays. Furthermore, the NV-N-R5-1 phage exhibited high specificity by detecting NV only in previously characterized NV-positive stool samples in contrast to no detection in NV-negative stool samples. These data demonstrate that the further development of NV-N-R5-1 phage as a diagnostic reagent is possible and might offer several distinct advantages over antibodies, such as decreases in the time and cost of production and ease of isolating phage against other epidemic strains currently circulating as well as those that are emerging.
NASA Astrophysics Data System (ADS)
Horii, Steven C.; Kundel, Harold L.; Shile, Peter E.; Carey, Bruce; Seshadri, Sridhar B.; Feingold, Eric R.
1994-05-01
As part of a study of the use of a PACS workstation compared to film in a Medical Intensive Care Unit, logs of workstation activity were maintained. The software for the workstation kept track of the type of user (i.e., intern, resident, fellow, or attending physician) and also of the workstation image manipulation functions used. The functions logged were: no operation, brightness/contrast adjustment, invert video, zoom, and high resolution display (this last function resulted in the display of the full 2 K X 2 K image rather than the usual subsampled 1 K X 1 K image. Associated data collection allows us to obtain the diagnostic category of the examination being viewed (e.g., location of tubes and lines, rule out: pneumonia, congestive heart failure, pneumothorax, and pleural effusion). The diagnostic categories and user type were then correlated with the use of workstation functions during viewing of images. In general, there was an inverse relationship between the level of training and the number of workstation uses. About two-thirds of the time, there was no image manipulation operation performed. Adjustment of brightness/contrast had the highest percentage of use overall, followed by zoom, video invert, and high resolution display.
Distributing Data from Desktop to Hand-Held Computers
NASA Technical Reports Server (NTRS)
Elmore, Jason L.
2005-01-01
A system of server and client software formats and redistributes data from commercially available desktop to commercially available hand-held computers via both wired and wireless networks. This software is an inexpensive means of enabling engineers and technicians to gain access to current sensor data while working in locations in which such data would otherwise be inaccessible. The sensor data are first gathered by a data-acquisition server computer, then transmitted via a wired network to a data-distribution computer that executes the server portion of the present software. Data in all sensor channels -- both raw sensor outputs in millivolt units and results of conversion to engineering units -- are made available for distribution. Selected subsets of the data are transmitted to each hand-held computer via the wired and then a wireless network. The selection of the subsets and the choice of the sequences and formats for displaying the data is made by means of a user interface generated by the client portion of the software. The data displayed on the screens of hand-held units can be updated at rates from 1 to
NASA Astrophysics Data System (ADS)
Senkbeil, J. C.; Brommer, D. M.; Comstock, I. J.; Loyd, T.
2012-07-01
Extratropical cyclones (ETCs) in the southern United States are often overlooked when compared with tropical cyclones in the region and ETCs in the northern United States. Although southern ETCs are significant weather events, there is currently not an operational scheme used for identifying and discussing these nameless storms. In this research, we classified 84 ETCs (1970-2009). We manually identified five distinct formation regions and seven unique ETC types using statistical classification. Statistical classification employed the use of principal components analysis and two methods of cluster analysis. Both manual and statistical storm types generally showed positive (negative) relationships with El Niño (La Niña). Manual storm types displayed precipitation swaths consistent with discrete storm tracks which further legitimizes the existence of multiple modes of southern ETCs. Statistical storm types also displayed unique precipitation intensity swaths, but these swaths were less indicative of track location. It is hoped that by classifying southern ETCs into types, that forecasters, hydrologists, and broadcast meteorologists might be able to better anticipate projected amounts of precipitation at their locations.
Yamasaki, Toshiki; Moritake, Kouzo; Nagai, Hidemasa; Kimura, Yoriyoshi
2002-06-01
A technique to integrate ultrasonography and endoscopy is described for transsphenoidal surgery to prevent intraoperative internal carotid artery (ICA)-related, life-threatening complications such as aneurysmal formation and carotid-cavernous fistula. The ultrasound unit helps avoid direct injury to the ICA. The technical advantage of this system is the miniature 1-mm diameter microvascular probe, which does not disturb the operative field. An arterial or venous flow source of even an invisible vessel can be detected easily, noninvasively, and reproducibly. Real-time information with a 100% detection rate for the ICA is helpful for predicting localization even in the intracavernous portion, where the ICA is invisible. The endoscope unit can visualize the dead angle areas of the operating microscope by varying the endoscopic gateways and display on a "picture-in-picture" system. The advantage of both devices is the integration with a video processor, so that the real-time information from each unit can be switched intraoperatively onto the display as required. This method is of particular help for removing lesions with intracavernous invasion or encasement of the ICA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atkin, Kate E.; Reiss, Renate; Turner, Nicholas J.
2008-03-01
Crystals of A. niger monoamine oxidase variants display P2{sub 1} or P4{sub 1}2{sub 1}2/P4{sub 3}2{sub 1}2 symmetry, with eight or two molecules in the asymmetric unit, respectively. Monoamine oxidase from Aspergillus niger (MAO-N) is an FAD-dependent enzyme that catalyses the conversion of terminal amines to their corresponding aldehydes. Variants of MAO-N produced by directed evolution have been shown to possess altered substrate specificity. Crystals of two of these variants (MAO-N-3 and MAO-N-5) have been obtained; the former displays P2{sub 1} symmetry with eight molecules per asymmetric unit and the latter has P4{sub 1}2{sub 1}2 or P4{sub 3}2{sub 1}2 symmetry andmore » two molecules per asymmetric unit. Solution of these structures will help shed light on the molecular determinants of improved activity and high enantioselectivity towards a broad range of substrates.« less
Dennis, Martin; Sandercock, Peter; Graham, Catriona; Forbes, John; Smith, J
2015-09-01
Venous thromboembolism (VTE) is a common cause of death and morbidity in stroke patients. There are few data concerning the effectiveness of intermittent pneumatic compression (IPC) in treating patients with stroke. To establish whether or not the application of IPC to the legs of immobile stroke patients reduced their risk of deep vein thrombosis (DVT). Clots in Legs Or sTockings after Stroke (CLOTS) 3 was a multicentre, parallel-group, randomised controlled trial which allocated patients via a central randomisation system to IPC or no IPC. A technician blinded to treatment allocation performed compression duplex ultrasound (CDU) of both legs at 7-10 days and 25-30 days after enrolment. We followed up patients for 6 months to determine survival and later symptomatic VTE. Patients were analysed according to their treatment allocation. We enrolled 2876 patients in 94 UK hospitals between 8 December 2008 and 6 September 2012. patients admitted to hospital within 3 days of acute stroke and who were immobile on the day of admission (day 0) to day 3. age < 16 years; subarachnoid haemorrhage; and contra-indications to IPC including dermatitis, leg ulcers, severe oedema, severe peripheral vascular disease and congestive cardiac failure. Participants were allocated to routine care or routine care plus IPC for 30 days, or until earlier discharge or walking independently. The primary outcome was DVT in popliteal or femoral veins, detected on a screening CDU, or any symptomatic DVT in the proximal veins, confirmed by imaging, within 30 days of randomisation. The secondary outcomes included death, any DVTs, symptomatic DVTs, pulmonary emboli, skin breaks on the legs, falls with injury or fractures and duration of IPC use occurring within 30 days of randomisation and survival, symptomatic VTE, disability (as measured by the Oxford Handicap Scale), quality of life (as measured by the European Quality of Life-5 Dimensions 3 Level questionnaire) and length of initial hospital stay measured 6 months after randomisation. We allocated 1438 patients to IPC and 1438 to no IPC. The primary outcome occurred in 122 (8.5%) of 1438 patients allocated to IPC and 174 (12.1%) of 1438 patients allocated to no IPC, giving an absolute reduction in risk of 3.6% [95% confidence interval (CI) 1.4% to 5.8%] and a relative risk reduction of 0.69 (95% CI 0.55 to 0.86). After excluding 323 patients who died prior to any primary outcome and 41 who had no screening CDU, the primary outcome occurred in 122 of 1267 IPC participants compared with 174 of 1245 no-IPC participants, giving an adjusted odds ratio of 0.65 (95% CI 0.51 to 0.84; p = 0.001). Secondary outcomes in IPC compared with no-IPC participants were death in the treatment period in 156 (10.8%) versus 189 (13.1%) (p = 0.058); skin breaks in 44 (3.1%) versus 20 (1.4%) (p = 0.002); and falls with injury in 33 (2.3%) versus 24 (1.7%) (p = 0.221). Among patients treated with IPC, there was a statistically significant improvement in survival to 6 months (hazard ratio 0.86, 95% CI 0.73 to 0.99; p = 0.042), but no improvement in disability. The direct cost of preventing a DVT was £1282 per event (95% CI £785 to £3077). IPC is an effective and inexpensive method of reducing the risk of DVT and improving survival in immobile stroke patients. Further research should test whether or not IPC improves survival in other groups of high-risk hospitalised medical patients. In addition, research into methods to improve adherence to IPC might increase the benefits of IPC in stroke patients. Current Controlled Trials ISRCTN93529999. The start-up phase of the trial (December 2008-March 2010) was funded by the Chief Scientist Office of the Scottish Government (reference number CZH/4/417). The main phase of the trial was funded by the National Institute for Health Research Health Technology Assessment programme (reference number 08/14/03). Covidien Ltd (Mansfield, MA, USA) lent its Kendall SCD™ Express sequential compression system controllers to the 105 centres involved in the trial and donated supplies of its sleeves. It also provided logistical help in keeping our centres supplied with sleeves and training materials relevant to the use of their devices. Recruitment and follow-up were supported by the National Institute for Health Research-funded UK Stroke Research Network and by the Scottish Stroke Research Network, which was supported by NHS Research Scotland.
Rail inspection system based on iGPS
NASA Astrophysics Data System (ADS)
Fu, Xiaoyan; Wang, Mulan; Wen, Xiuping
2018-05-01
Track parameters include gauge, super elevation, cross level and so on, which could be calculated through the three-dimensional coordinates of the track. The rail inspection system based on iGPS (indoor/infrared GPS) was composed of base station, receiver, rail inspection frame, wireless communication unit, display and control unit and data processing unit. With the continuous movement of the inspection frame, the system could accurately inspect the coordinates of rail; realize the intelligent detection and precision measurement. According to principle of angle intersection measurement, the inspection model was structured, and detection process was given.
NASA work unit system users manual
NASA Technical Reports Server (NTRS)
1972-01-01
The NASA Work Unit System is a management information system for research tasks (i.e., work units) performed under NASA grants and contracts. It supplies profiles to indicate how much effort is being expended to what types of research, where the effort is being expended, and how funds are being distributed. The user obtains information by entering requests on the keyboard of a time-sharing terminal. Responses are received as video displays or typed messages at the terminal, or as lists printed in the computer room for subsequent delivery by messenger.
OPO-based compact laser projection display
NASA Astrophysics Data System (ADS)
Lee, Dicky; Moulton, Peter F.; Bergstedt, Robert; Flint, Graham W.
2001-09-01
In this paper we discuss our red, green, and blue (RGB) optical parametric oscillator (OPO) based laser projection display. The complete project display consists of two subsystems, the RGB-OPO laser head and the light modulation unit. The RGB lights from rack-mounted laser head are fibers coupled to the projection unit for independent placement. The light source consists of a diode-pumped pump laser and a LBO-based OPO. Based on our Nd:YLF gain module design, the pump laser is frequency doubled to serve as the pump source for the OPO. The unconverted pump power is recycled as the green light for projection. The singly resonant, non- critically phase-matched (NCPM) OPO has, to date, generated 13 W of 898-nm signal power and an estimated 9.3 W of intra- cavity idler power at 1256 nm. With approximately 76% of pump depletion, the power of the residual green light for projection is about 5.8 W. We have extra-cavity doubled the signal to produce approximately 3.5 W of 449-nm blue light and intra-cavity doubled the idler to produce approximately 6 W of 628-nm red light. The OPO-based RGB source generates about 4000 lumens of D65-balanced white light. The overall electrical power on a commercially available JVC's three- panel D-ILA (reflective LCD) projector with the arc-lamp removed and extensive modifications. The projector has a native resolution of 1365 x 1024 and the expected on screen lumens from our laser display is about 1200 lumens.
Study of cryogenic propellant systems for loading the space shuttle. Part 2: Hydrogen systems
NASA Technical Reports Server (NTRS)
Steward, W. G.
1975-01-01
Computer simulation studies of liquid hydrogen fill and vent systems for the space shuttle are studied. The computer programs calculate maximum and minimum permissible flow rates during cooldown as limited by thermal stress considerations, fill line cooldown time, pressure drop, flow rates, vapor content, vent line pressure drop and vent line discharge temperature. The input data for these programs are selected through graphic displays which schematically depict the part of the system being analyzed. The computed output is also displayed in the form of printed messages and graphs. Digital readouts of graph coordinates may also be obtained. Procedures are given for operation of the graphic display unit and the associated minicomputer and timesharing computer.
Evolving mobile robots able to display collective behaviors.
Baldassarre, Gianluca; Nolfi, Stefano; Parisi, Domenico
2003-01-01
We present a set of experiments in which simulated robots are evolved for the ability to aggregate and move together toward a light target. By developing and using quantitative indexes that capture the structural properties of the emerged formations, we show that evolved individuals display interesting behavioral patterns in which groups of robots act as a single unit. Moreover, evolved groups of robots with identical controllers display primitive forms of situated specialization and play different behavioral functions within the group according to the circumstances. Overall, the results presented in the article demonstrate that evolutionary techniques, by exploiting the self-organizing behavioral properties that emerge from the interactions between the robots and between the robots and the environment, are a powerful method for synthesizing collective behavior.
ERIC Educational Resources Information Center
Desler, Gail
In this grade 6 interdisciplinary language arts and social studies unit, students are required to assume the role of a team and describe their country's participation in trade along the Silk Road. Countries represented in the unit include Egypt, Italy, Iraq, India, Israel, and China. The team is asked to create a display showing artifacts, journal…
Characterization of feed coal and coal combustion products from power plants in Indiana and Kentucky
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brownfield, M.E.; Affolter, R.H.; Cathcart, J.D.
1999-07-01
The US Geological Survey, Kentucky Geological Survey, and the University of Kentucky Center for Applied Energy Research are collaborating with Indiana and Kentucky utilities to determine the physical and chemical properties of feed coal and coal combustion products (CCP) from three coal-fired power plants. These three plants are designated as Units K1, K2, and I1 and burn high-, moderate-, and low-sulfur coals, respectively. Over 200 samples of feed coal and CCP were analyzed by various chemical and mineralogical methods to determine mode of occurrence and distribution of trace elements in the CCP. Generally, feed coals from all 3 Units containmore » mostly well-crystallized kaolinite and quartz. Comparatively, Unit K1 feed coals have higher amounts of carbonates, pyrite and sphalerite. Unit K2 feed coals contain higher kaolinite and illite/muscovite when compared to Unit K1 coals. Unit I1 feed coals contain beta-form quartz and alumino-phosphates with minor amounts of calcite, micas, anatase, and zircon when compared to K1 and K2 feed coals. Mineralogy of feed coals indicate that the coal sources for Units K1 and K2 are highly variable, with Unit K1 displaying the greatest mineralogic variability; Unit I1 feed coal however, displayed little mineralogic variation supporting a single source. Similarly, element contents of Units K1 and K2 feed coals show more variability than those of Unit I1. Fly ash samples from Units K1 and K2 consist mostly of glass, mullite, quartz, and spines group minerals. Minor amounts of illite/muscovite, sulfates, hematite, and corundum are also present. Spinel group minerals identified include magnetite, franklinite, magnesioferrite, trevorite, jacobisite, and zincochromite. Scanning Electron Microscope analysis reveals that most of the spinel minerals are dendritic intergrowths within aluminum silicate glass. Unit I1 fly ash samples contain glass, quartz, perovskite, lime, gehlenite, and apatite with minor amounts of periclase, anhydrite, carbonates, pyroxenes, and spinels. The abundant Ca mineral phases in the Unit I1 fly ashes are attributed to the presence of carbonate, clay and phosphate minerals in the coal.« less
Multiple-Flat-Panel System Displays Multidimensional Data
NASA Technical Reports Server (NTRS)
Gundo, Daniel; Levit, Creon; Henze, Christopher; Sandstrom, Timothy; Ellsworth, David; Green, Bryan; Joly, Arthur
2006-01-01
The NASA Ames hyperwall is a display system designed to facilitate the visualization of sets of multivariate and multidimensional data like those generated in complex engineering and scientific computations. The hyperwall includes a 77 matrix of computer-driven flat-panel video display units, each presenting an image of 1,280 1,024 pixels. The term hyperwall reflects the fact that this system is a more capable successor to prior computer-driven multiple-flat-panel display systems known by names that include the generic term powerwall and the trade names PowerWall and Powerwall. Each of the 49 flat-panel displays is driven by a rack-mounted, dual-central-processing- unit, workstation-class personal computer equipped with a hig-hperformance graphical-display circuit card and with a hard-disk drive having a storage capacity of 100 GB. Each such computer is a slave node in a master/ slave computing/data-communication system (see Figure 1). The computer that acts as the master node is similar to the slave-node computers, except that it runs the master portion of the system software and is equipped with a keyboard and mouse for control by a human operator. The system utilizes commercially available master/slave software along with custom software that enables the human controller to interact simultaneously with any number of selected slave nodes. In a powerwall, a single rendering task is spread across multiple processors and then the multiple outputs are tiled into one seamless super-display. It must be noted that the hyperwall concept subsumes the powerwall concept in that a single scene could be rendered as a mosaic image on the hyperwall. However, the hyperwall offers a wider set of capabilities to serve a different purpose: The hyperwall concept is one of (1) simultaneously displaying multiple different but related images, and (2) providing means for composing and controlling such sets of images. In place of elaborate software or hardware crossbar switches, the hyperwall concept substitutes reliance on the human visual system for integration, synthesis, and discrimination of patterns in complex and high-dimensional data spaces represented by the multiple displayed images. The variety of multidimensional data sets that can be displayed on the hyperwall is practically unlimited. For example, Figure 2 shows a hyperwall display of surface pressures and streamlines from a computational simulation of airflow about an aerospacecraft at various Mach numbers and angles of attack. In this display, Mach numbers increase from left to right and angles of attack increase from bottom to top. That is, all images in the same column represent simulations at the same Mach number, while all images in the same row represent simulations at the same angle of attack. The same viewing transformations and the same mapping from surface pressure to colors were used in generating all the images.
Contrast Transmission In Medical Image Display
NASA Astrophysics Data System (ADS)
Pizer, Stephen M.; Zimmerman, John B.; Johnston, R. Eugene
1982-11-01
The display of medical images involves transforming recorded intensities such at CT numbers into perceivable intensities such as combinations of color and luminance. For the viewer to extract the most information about patterns of decreasing and increasing recorded intensity, the display designer must pay attention to three issues: 1) choice of display scale, including its discretization; 2) correction for variations in contrast sensitivity across the display scale due to the observer and the display device (producing an honest display); and 3) contrast enhancement based on the information in the recorded image and its importance, determined by viewing objectives. This paper will present concepts and approaches in all three of these areas. In choosing display scales three properties are important: sensitivity, associability, and naturalness of order. The unit of just noticeable difference (jnd) will be carefully defined. An observer experiment to measure the jnd values across a display scale will be specified. The overall sensitivity provided by a scale as measured in jnd's gives a measure of sensitivity called the perceived dynamic range (PDR). Methods for determining the PDR fran the aforementioned PDR values, and PDR's for various grey and pseudocolor scales will be presented. Methods of achieving sensitivity while retaining associability and naturalness of order with pseudocolor scales will be suggested. For any display device and scale it is useful to compensate for the device and observer by preceding the device with an intensity mapping (lookup table) chosen so that perceived intensity is linear with display-driving intensity. This mapping can be determined from the aforementioned jnd values. With a linearized display it is possible to standardize display devices so that the same image displayed on different devices or scales (e.g. video and hard copy) will be in sane sense perceptually equivalent. Furthermore, with a linearized display, it is possible to design contrast enhancement mappings that optimize the transmission of information from the recorded image to the display-driving signal with the assurance that this information will not then be lost by a -further nonlinear relation between display-driving and perceived intensity. It is suggested that optimal contrast enhancement mappings are adaptive to the local distribution of recorded intensities.
Official portrait of astronaut Ronald J. Grabe
NASA Technical Reports Server (NTRS)
1989-01-01
Official portrait of Ronald J. Grabe, United States Air Force (USAF) Colonel, member of Astronaut Class 9 (1980), and space shuttle pilot. Grabe wears launch and entry suit (LES) with helmet displayed on table at his left.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
... Motion-Sensitive Sound Effects Devices and Image Display Devices and Components and Products Containing... sale within the United States after importation of certain motion- sensitive sound devices and image...
Simulation procedure for modeling transient water table and artesian stress and response
Reed, J.E.; Bedinger, M.S.; Terry, J.E.
1976-01-01
The series of computer programs described in this report were designed specifically to model the ground-water regime in sufficient detail to determine the effects of the imposition of various types of stress upon the system, and to display the results in a convenient manner during calibration and when presenting projected data. SUPERMOCK simulates the ground-water system and DATE and HYDROG aid in the display of computed data. During calibration, DATE is especially useful because it has the optional feature of comparing computed data with observed data. Although the programs can be run independently, experience dictates that for best results the three should be run as steps in the same job. English units of inches, feet, and days are used in each of the programs. The units for any parameters not given in the text are clearly specified in the instructions for input to the individual programs. (Woodard-USGS)
Designing User Interfaces for Smart-Applications for Operating Rooms and Intensive Care Units
NASA Astrophysics Data System (ADS)
Kindsmüller, Martin Christof; Haar, Maral; Schulz, Hannes; Herczeg, Michael
Today’s physicians and nurses working in operating rooms and intensive care units have to deal with an ever increasing amount of data. More and more medical devices are delivering information, which has to be perceived and interpreted in regard to patient status and the necessity to adjust therapy. The combination of high information load and insufficient usability creates a severe challenge for the health personnel with respect to proper monitoring of these devices respective to acknowledging alarms and timely reaction to critical incidents. Smart Applications are a new kind of decision support systems that incorporate medical expertise in order to help health personnel in regard to diagnosis and therapy. By means of a User Centered Design process of two Smart Applications (anaesthesia monitor display, diagnosis display), we illustrate which approach should be followed and which processes and methods have been successfully applied in fostering the design of usable medical devices.
Help for the Visually Impaired
NASA Technical Reports Server (NTRS)
1995-01-01
The Low Vision Enhancement System (LVES) is a video headset that offers people with low vision a view of their surroundings equivalent to the image on a five-foot television screen four feet from the viewer. It will not make the blind see but for many people with low vision, it eases everyday activities such as reading, watching TV and shopping. LVES was developed over almost a decade of cooperation between Stennis Space Center, the Wilmer Eye Institute of the Johns Hopkins Medical Institutions, the Department of Veteran Affairs, and Visionics Corporation. With the aid of Stennis scientists, Wilmer researchers used NASA technology for computer processing of satellite images and head-mounted vision enhancement systems originally intended for the space station. The unit consists of a head-mounted video display, three video cameras, and a control unit for the cameras. The cameras feed images to the video display in the headset.
Laser-assisted fabrication of single-layer flexible touch sensor
Son, Seokwoo; Park, Jong Eun; Lee, Joohyung; Yang, Minyang; Kang, Bongchul
2016-01-01
Single-layer flexible touch sensor that is designed for the indium-tin-oxide (ITO)-free, bendable, durable, multi-sensible, and single layer transparent touch sensor was developed via a low-cost and one-step laser-induced fabrication technology. To this end, an entirely novel approach involving material, device structure, and even fabrication method was adopted. Conventional metal oxides based multilayer touch structure was substituted by the single layer structure composed of integrated silver wire networks of sensors and bezel interconnections. This structure is concurrently fabricated on a glass substitutive plastic film via the laser-induced fabrication method using the low-cost organometallic/nanoparticle hybrid complex. In addition, this study addresses practical solutions to heterochromia and interference problem with a color display unit. As a result, a practical touch sensor is successfully demonstrated through resolving the heterochromia and interference problems with color display unit. This study could provide the breakthrough for early realization of wearable device. PMID:27703204
NASA Technical Reports Server (NTRS)
1974-01-01
A methodology for the display and analysis of postulated energy futures for the United States is presented. A systems approach methodology including the methodology of technology assessment is used to examine three energy scenarios--the Westinghouse Nuclear Electric Economy, the Ford Technical Fix Base Case and a MEGASTAR generated Alternate to the Ford Technical Fix Base Case. The three scenarios represent different paths of energy consumption from the present to the year 2000. Associated with these paths are various mixes of fuels, conversion, distribution, conservation and end-use technologies. MEGASTAR presents the estimated times and unit requirements to supply the fuels, conversion and distribution systems for the postulated end uses for the three scenarios and then estimates the aggregate manpower, materials, and capital requirements needed to develop the energy system described by the particular scenario.
Portable Dynamic Pressure Calibrator
NASA Technical Reports Server (NTRS)
Wright, Morgan S.; Maynard, Everett (Technical Monitor)
1996-01-01
A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.
Martin, Edward J [Virginia Beach, VA
2008-01-15
A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.
NASA Technical Reports Server (NTRS)
Head, J. W., III (Principal Investigator)
1982-01-01
The nature of the HCMM data set and the general geologic application of thermal inertia imaging using HCMM data were studied. The CCT's of five sites of interest were obtained and displayed. The upgrading of the image display system was investigated. Fragment/block size distributions in various terrain types wre characterized with emphasis on volcanic terrain. The SEASAT L-band radar images of volcanic landforms at Newberry Volcano, Oregon, were analyzed and compared to imagery from LANDSAT band 7.
Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C
2012-01-01
Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.
Wolcott, Stephen W.
2005-01-01
Aquifers (water bearing geologic units) are the primary source of drinking water in most of Putnam County, N.Y. The principal sources of data used to define the geometry and hydraulic characteristics of aquifers are the logs of wells and test holes within the county. This report explains how to use a graphical viewer, available on the World Wide Web (http://ny.water.usgs.gov/pubs/of/of051198), to locate selected wells and test holes in Putnam County and display their logs.
IVTS-CEV (Interactive Video Tape System-Combat Engineer Vehicle) Gunnery Trainer.
1981-07-01
video game technology developed for and marketed in consumer video games. The IVTS/CEV is a conceptual/breadboard-level classroom interactive training system designed to train Combat Engineer Vehicle (CEV) gunners in target acquisition and engagement with the main gun. The concept demonstration consists of two units: a gunner station and a display module. The gunner station has optics and gun controls replicating those of the CEV gunner station. The display module contains a standard large-screen color video monitor and a video tape player. The gunner’s sight
In sight, in mind: retailer compliance with legislation on limiting retail tobacco displays.
Quedley, Megan; Ng, Brendan; Sapre, Nikhil; Blakiston, Matthew; Crawford, Alexandra; Devadas, Rosanne; McLaren, Hamish; Anand, Shruti; Tipu, Mahu; Dayal, Viswas; Chandrasiri, Singithi; Thomson, George; Edwards, Richard
2008-08-01
We investigated retailer compliance with point-of-sale display legislation, using a New Zealand region as a case study. An observational survey was conducted of nonspecialist tobacco retailers in the lower North Island of New Zealand during 2006. Compliance was assessed in relation to store type (dairies, convenience stores, supermarkets, and service stations) and by characteristics of the population of the census area unit in which the store was situated. These characteristics include the level of socioeconomic deprivation and proportions of Maori (indigenous New Zealanders), Pacific Islanders, and children aged less than 19 years. Out of the 288 stores surveyed, 185 (64%) had at least one breach of the point-of-sale regulations. The most common breaches were a failure to display a "Smoking Kills" sign, visibility of tobacco from outside the premises, and displaying tobacco less than 1 m from children's products. Compliance was significantly worse in dairies (small local general stores) and convenience stores. Stores situated in areas in the top quartile for the proportion of children were much more likely to have high levels of noncompliance (> or =3 breaches) and to display tobacco products close to children's products. This study is one of very few to systematically investigate retailer compliance with point-of-sale display regulations for tobacco products. The results suggest that the implementation of legislation to partly limit retail displays of tobacco products can be difficult. A ban on retail displays of tobacco products is likely to be a more effective and enforceable policy.
Official portrait of astronaut Brewster H. Shaw, Jr
NASA Technical Reports Server (NTRS)
1989-01-01
Official portrait of Brewster H. Shaw, Jr, United States Air Force (USAF) Colonel, member of Astronaut Class 8 (1978), and space shuttle commander. Shaw wears blue pressure suit with space shuttle model displayed on table on his left.
Faster, Better, Cheaper: A Decade of PC Progress.
ERIC Educational Resources Information Center
Crawford, Walt
1997-01-01
Reviews the development of personal computers and how computer components have changed in price and value. Highlights include disk drives; keyboards; displays; memory; color graphics; modems; CPU (central processing unit); storage; direct mail vendors; and future possibilities. (LRW)
2000-10-26
This plaque, displayed on the grounds of Marshall Space Flight Center in Huntsville, Alabama, commemorates the Redstone Test Stand as a National Historic Landmark. The site was designated as such in 1985 by the National Park Service of the United States Department of the Interior.
Official portrait of astronaut David C. Hilmers
NASA Technical Reports Server (NTRS)
1990-01-01
Official portrait of David C. Hilmers, United States Marine Corps (USMC) Colonel, member of Astronaut Class 9 (1980), and space shuttle mission specialist. Hilmers wears launch and entry suit (LES) with his helmet displayed on table in front of him.
Investigations of Volcanic and Volatile-Driven Processes Northeast of Hellas Basin, Mars
NASA Astrophysics Data System (ADS)
Mest, S. C.; Crown, D. A.; Michalski, J.; Chuang, F. C.; Price Blount, K.; Bleamaster, L. F.
2018-06-01
We are mapping the geologic units and features in three MTM quadrangles northeast of Hellas basin at 1:1M scale. The area displays evidence for volcanism and widespread volatile-related modification of the surface.
NASA Technical Reports Server (NTRS)
Glover, Richard D.
1987-01-01
A pipelined, multiprocessor, general-purpose ground support equipment for digital flight systems has been developed and placed in service at the NASA Ames Research Center's Dryden Flight Research Facility. The design is an outgrowth of the earlier aircraft interrogation and display system (AIDS) used in support of several research projects to provide engineering-units display of internal control system parameters during development and qualification testing activities. The new system, incorporating multiple 16-bit processors, is called extended AIDS (XAIDS) and is now supporting the X-29A forward-swept-wing aircraft project. This report describes the design and mechanization of XAIDS and shows the steps whereby a typical user may take advantage of its high throughput and flexible features.
The Pluto system: Initial results from its exploration by New Horizons
NASA Astrophysics Data System (ADS)
Stern, S. A.; Bagenal, F.; Ennico, K.; Gladstone, G. R.; Grundy, W. M.; McKinnon, W. B.; Moore, J. M.; Olkin, C. B.; Spencer, J. R.; Weaver, H. A.; Young, L. A.; Andert, T.; Andrews, J.; Banks, M.; Bauer, B.; Bauman, J.; Barnouin, O. S.; Bedini, P.; Beisser, K.; Beyer, R. A.; Bhaskaran, S.; Binzel, R. P.; Birath, E.; Bird, M.; Bogan, D. J.; Bowman, A.; Bray, V. J.; Brozovic, M.; Bryan, C.; Buckley, M. R.; Buie, M. W.; Buratti, B. J.; Bushman, S. S.; Calloway, A.; Carcich, B.; Cheng, A. F.; Conard, S.; Conrad, C. A.; Cook, J. C.; Cruikshank, D. P.; Custodio, O. S.; Dalle Ore, C. M.; Deboy, C.; Dischner, Z. J. B.; Dumont, P.; Earle, A. M.; Elliott, H. A.; Ercol, J.; Ernst, C. M.; Finley, T.; Flanigan, S. H.; Fountain, G.; Freeze, M. J.; Greathouse, T.; Green, J. L.; Guo, Y.; Hahn, M.; Hamilton, D. P.; Hamilton, S. A.; Hanley, J.; Harch, A.; Hart, H. M.; Hersman, C. B.; Hill, A.; Hill, M. E.; Hinson, D. P.; Holdridge, M. E.; Horanyi, M.; Howard, A. D.; Howett, C. J. A.; Jackman, C.; Jacobson, R. A.; Jennings, D. E.; Kammer, J. A.; Kang, H. K.; Kaufmann, D. E.; Kollmann, P.; Krimigis, S. M.; Kusnierkiewicz, D.; Lauer, T. R.; Lee, J. E.; Lindstrom, K. L.; Linscott, I. R.; Lisse, C. M.; Lunsford, A. W.; Mallder, V. A.; Martin, N.; McComas, D. J.; McNutt, R. L.; Mehoke, D.; Mehoke, T.; Melin, E. D.; Mutchler, M.; Nelson, D.; Nimmo, F.; Nunez, J. I.; Ocampo, A.; Owen, W. M.; Paetzold, M.; Page, B.; Parker, A. H.; Parker, J. W.; Pelletier, F.; Peterson, J.; Pinkine, N.; Piquette, M.; Porter, S. B.; Protopapa, S.; Redfern, J.; Reitsema, H. J.; Reuter, D. C.; Roberts, J. H.; Robbins, S. J.; Rogers, G.; Rose, D.; Runyon, K.; Retherford, K. D.; Ryschkewitsch, M. G.; Schenk, P.; Schindhelm, E.; Sepan, B.; Showalter, M. R.; Singer, K. N.; Soluri, M.; Stanbridge, D.; Steffl, A. J.; Strobel, D. F.; Stryk, T.; Summers, M. E.; Szalay, J. R.; Tapley, M.; Taylor, A.; Taylor, H.; Throop, H. B.; Tsang, C. C. C.; Tyler, G. L.; Umurhan, O. M.; Verbiscer, A. J.; Versteeg, M. H.; Vincent, M.; Webbert, R.; Weidner, S.; Weigle, G. E.; White, O. L.; Whittenburg, K.; Williams, B. G.; Williams, K.; Williams, S.; Woods, W. W.; Zangari, A. M.; Zirnstein, E.
2015-10-01
The Pluto system was recently explored by NASA’s New Horizons spacecraft, making closest approach on 14 July 2015. Pluto’s surface displays diverse landforms, terrain ages, albedos, colors, and composition gradients. Evidence is found for a water-ice crust, geologically young surface units, surface ice convection, wind streaks, volatile transport, and glacial flow. Pluto’s atmosphere is highly extended, with trace hydrocarbons, a global haze layer, and a surface pressure near 10 microbars. Pluto’s diverse surface geology and long-term activity raise fundamental questions about how small planets remain active many billions of years after formation. Pluto’s large moon Charon displays tectonics and evidence for a heterogeneous crustal composition; its north pole displays puzzling dark terrain. Small satellites Hydra and Nix have higher albedos than expected.
Automated Analysis, Classification, and Display of Waveforms
NASA Technical Reports Server (NTRS)
Kwan, Chiman; Xu, Roger; Mayhew, David; Zhang, Frank; Zide, Alan; Bonggren, Jeff
2004-01-01
A computer program partly automates the analysis, classification, and display of waveforms represented by digital samples. In the original application for which the program was developed, the raw waveform data to be analyzed by the program are acquired from space-shuttle auxiliary power units (APUs) at a sampling rate of 100 Hz. The program could also be modified for application to other waveforms -- for example, electrocardiograms. The program begins by performing principal-component analysis (PCA) of 50 normal-mode APU waveforms. Each waveform is segmented. A covariance matrix is formed by use of the segmented waveforms. Three eigenvectors corresponding to three principal components are calculated. To generate features, each waveform is then projected onto the eigenvectors. These features are displayed on a three-dimensional diagram, facilitating the visualization of the trend of APU operations.
Spacesuit Data Display and Management System
NASA Technical Reports Server (NTRS)
Hall, David G.; Sells, Aaron; Shah, Hemal
2009-01-01
A prototype embedded avionics system has been designed for the next generation of NASA extra-vehicular-activity (EVA) spacesuits. The system performs biomedical and other sensor monitoring, image capture, data display, and data transmission. An existing NASA Phase I and II award winning design for an embedded computing system (ZIN vMetrics - BioWATCH) has been modified. The unit has a reliable, compact form factor with flexible packaging options. These innovations are significant, because current state-of-the-art EVA spacesuits do not provide capability for data displays or embedded data acquisition and management. The Phase 1 effort achieved Technology Readiness Level 4 (high fidelity breadboard demonstration). The breadboard uses a commercial-grade field-programmable gate array (FPGA) with embedded processor core that can be upgraded to a space-rated device for future revisions.
Geomorphological Mapping of Sputnik Planum and Surrounding Terrain on Pluto
NASA Astrophysics Data System (ADS)
White, O. L.; Stern, S. A.; Weaver, H. A., Jr.; Olkin, C.; Ennico Smith, K.; Young, L. A.; Moore, J. M.; Cheng, A. F.
2015-12-01
The New Horizons flyby of Pluto in July 2015 has provided the first few close-up images of the Kuiper belt object, which reveal it to have a highly diverse range of terrains, implying a complex geological history. The highest resolution images that have yet been returned are seven lossy 400 m/pixel frames that cover the majority of the prominent Plutonian feature informally named Sputnik Planum (all feature names are currently informal), and its surroundings. This resolution is sufficient to allow detailed geomorphological mapping of this area to commence. Lossless versions of all 15 frames that make up the mosaic will be returned in September 2015, and the map presented at AGU will incorporate the total area covered by these frames. Sputnik Planum, with an area of ~650,000 km2, is notable for its smooth appearance and apparent total lack of impact craters at 400 m/pixel resolution. The Planum actually displays a wide variety of textures across its expanse, which includes smooth and pitted plains to the south, polygonal terrain at its center (the polygons can reach tens of kilometers in size and are bounded by troughs that sometimes feature central ridges), and, to the north, darker polygonal terrain displaying patterns indicative of glacial flow. Within these plains there exist several well-defined outcrops of a mottled, light/dark unit that reach from several to tens of kilometers across. Separating Sputnik Planum from the dark, cratered equatorial terrain of Cthulhu Regio on its south-western margin is a unit of chaotically arranged mountains; similar mountainous units exist on the south and western margins. The northern margin is bounded by rugged, hilly, cratered terrain into which ice of Sputnik Planum appears to be intruding in places. Terrain of similar relief exists to the east, but is much brighter than that to the north. The southernmost extent of the mosaic features a unit of rough, undulating terrain that displays very few impact craters at 400 m/pixel resolution.
Self-organization in P_xGe_xSe_1-2x glasses^*
NASA Astrophysics Data System (ADS)
Chakravarty, Swapnajit; Georgiev, Daniel; Boolchand, Punit; Micoulaut, Matthieu
2003-03-01
Bulk glasses in the titled ternary, in the 0 < x < 0.26 composition range, are examined in MDSC and Raman scattering measurements. Both fresh and aged samples were studied. Bimodal endotherms are observed but only the high^T endotherm displays a reversing heat flow signal that represents a glass transition. The pre^_Tg endotherm is observed in quenched samples only, and represents an activation energy [1] associated with P4 units (Se^_P(Se_1/2)_3) converting to P3 (P(Se_1/2)_3) ones. T_g(x) accessed from the reversing heat flow are found to increase with x as a power^_law, displaying a cusp near x = 0.04. The non^_reversing enthalpy is found to display a global minimum in the 0.08 < x < 0.145 range identified with the self^_organized phase. Raman scattering reveals the isostatically rigid units ( P3 , P_4, CS and ES Ge(Se_1/2)_4) comprising building blocks of the self^_organized phase. These results are parallel to those encountered in the As^_Ge^_Se ternary [2,3]. ^*Supported by NSF grant DMR ^_01^_01808 1. D.G. Georgiev et al Phys. Rev. B 64,134204(2001) 2.Y. Wang et al Europhys. Lett. 52, 633 (2000) 3. T.Qu et al. companion abstract
An integrated port camera and display system for laparoscopy.
Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E
2010-05-01
In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.
Unlocking the condoms: The effect on sales and theft.
Ashwood, Daniel; Farris, Karen B; Campo, Shelly; Aquilino, Mary L; Losch, Mary
2011-01-01
Community pharmacies may place condoms in locked displays or behind glass, thereby reducing access and consequent use. Quantify sales and theft of condoms when condoms were unlocked and removed from behind glass in grocery pharmacies. Design. In this pilot study, condom displays were unlocked in selected pharmacies for three months. Participants. Eight grocery pharmacies in central Iowa agreed to participate. Intervention. Stores provided inventory at baseline, sales/theft thereafter in three monthly reports and sales for the same period one-year earlier. Outcome measures. Descriptive statistics quantified condom theft and sales. Number of pharmacies leaving condoms unlocked after the intervention was determined. Theft varied by pharmacy and ranged from an average of 1.33 boxes (units) per month to 27.33 per month. All stores experienced some increase in sales during the intervention. Two locations decided to re-lock their displays, only one indicated theft as the reason. After removing condoms from locked displays, more condoms were purchased and stolen from the study pharmacies. Sales outweighed theft in all pharmacies.
Lighting Control System for Premises with Display Screen Equipment
NASA Astrophysics Data System (ADS)
Kudryashov, A. V.
2017-11-01
The use of Display Screen Equipment (DSE) at enterprises allows one to increase the productivity and safety of production, minimize the number of personnel and leads to the simplification of the work of specialists, but on the other side, changes usual working conditions. If the personnel works with displays, visual fatigue develops more quickly which contributes to the emergence of nervous tension, stress and possible erroneous actions. Low interest of the lighting control system developers towards the rooms with displays is dictated by special requirements for coverage by sanitary and hygienic standards (limiting excess workplace illumination). We decided to create a combined lighting system which works considering daylight illumination and artificial light sources. The brightness adjustment of the LED lamps is carried out according to the DALI protocol, adjustment of the natural illumination by means of smart glasses. The technical requirements for a lighting control system, the structural-functional scheme and the algorithm for controlling the operation of the system have been developed. The elements of control units, sensors and actuators have been selected.
NASA Technical Reports Server (NTRS)
Sawyer, Kevin; Jacobsen, Robert; Aiken, Edwin W. (Technical Monitor)
1995-01-01
NASA Ames Research Center and the US Army are developing the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) using a Sikorsky UH-60 helicopter for the purpose of flight systems research. A primary use of the RASCAL is in-flight simulation for which the visual scene will use computer generated imagery and synthetic vision. This research is made possible in part to a full color wide field of view Helmet Mounted Display (HMD) system that provides high performance color imagery suitable for daytime operations in a flight-rated package. This paper describes the design and performance characteristics of the HMD system. Emphasis is placed on the design specifications, testing, and integration into the aircraft of Kaiser Electronics' RASCAL HMD system that was designed and built under contract for NASA. The optical performance and design of the Helmet mounted display unit will be discussed as well as the unique capabilities provided by the system's Programmable Display Generator (PDG).
Payload specialist station study: Volume 2, part 3: Program analysis and planning for phase C/D
NASA Technical Reports Server (NTRS)
1976-01-01
The controls and displays (C&D) required at the Orbiter aft-flight deck (AFD) and the core C&D required at the Payload Specialist Station (PSS) are identified in this document. The AFD C&D Concept consists of a multifunction display system (MFDS) and elements of multiuse mission support equipment (MMSE). The MFDS consists of two CRTs, a display electronics unit (DEU), and a keyboard. The MMSE consists of a manual pointing controller (MPC), five digit numeric displays, 10 character alphanumeric legends, event timers, analog meters, rotary and toggle switches. The MMSE may be hardwired to the experiment, or interface with a data bus at the PSS for signal processing. The MFDS has video capability, with alphanumeric and graphic overlay features, on one CRT and alphanumeric and graphic (tricolor) capability on a second CRT. The DEU will have the capability to communicate, via redundant data buses, with both the spacelab experiment and subsystem computers.
Space Shuttle Placement Announcement
2011-04-12
From left, Pilot of the first space shuttle mission, STS-1, Bob Crippen, NASA Administrator Charles Bolden, NASA Johnson Space Center Director of Flight Crew Operations, and Astronaut, Janet Kavandi, NASA Kennedy Space Center Director and former astronaut Bob Cabana, and Endeavour Vehicle Manager for United Space Alliance Mike Parrish pose for a photograph outside of the an Orbiter Processing Facility with the space shuttle Atlantis shortly after Bolden announced where four space shuttle orbiters will be permanently displayed at the conclusion of the Space Shuttle Program, Tuesday, April 12, 2011, at Kennedy Space Center in Cape Canaveral, Fla. The four orbiters, Enterprise, which currently is on display at the Smithsonian's Steven F. Udvar-Hazy Center near Washington Dulles International Airport, will move to the Intrepid Sea, Air & Space Museum in New York, Discovery will move to Udvar-Hazy, Endeavour will be displayed at the California Science Center in Los Angeles and Atlantis, in background, will be displayed at the Kennedy Space Center Visitor’s Complex. Photo Credit: (NASA/Bill Ingalls)
The use of phage display in neurobiology.
Bradbury, Andrew R M
2010-04-01
Phage display has been extensively used to study protein-protein interactions, receptor- and antibody-binding sites, and immune responses, to modify protein properties, and to select antibodies against a wide range of different antigens. In the format most often used, a polypeptide is displayed on the surface of a filamentous phage by genetic fusion to one of the coat proteins, creating a chimeric coat protein, and coupling phenotype (the protein) to genotype (the gene within). As the gene encoding the chimeric coat protein is packaged within the phage, selection of the phage on the basis of the binding properties of the polypeptide displayed on the surface simultaneously results in the isolation of the gene encoding the polypeptide. This unit describes the background to the technique, and illustrates how it has been applied to a number of different problems, each of which has its neurobiological counterparts. Although this overview concentrates on the use of filamentous phage, which is the most popular platform, other systems are also described. (c) 2010 by John Wiley & Sons, Inc.
NASA Astrophysics Data System (ADS)
Deckard, Michael; Ratib, Osman M.; Rubino, Gregory
2002-05-01
Our project was to design and implement a ceiling-mounted multi monitor display unit for use in a high-field MRI surgical suite. The system is designed to simultaneously display images/data from four different digital and/or analog sources with: minimal interference from the adjacent high magnetic field, minimal signal-to-noise/artifact contribution to the MRI images and compliance with codes and regulations for the sterile neuro-surgical environment. Provisions were also made to accommodate the importing and exporting of video information via PACS and remote processing/display for clinical and education uses. Commercial fiber optic receivers/transmitters were implemented along with supporting video processing and distribution equipment to solve the video communication problem. A new generation of high-resolution color flat panel displays was selected for the project. A custom-made monitor mount and in-suite electronics enclosure was designed and constructed at UCLA. Difficulties with implementing an isolated AC power system are discussed and a work-around solution presented.
Combined Utility/Transportation Tunnel Systems - Economic, Technical and Institutional Feasibility
DOT National Transportation Integrated Search
1976-07-01
Although utility tunnels are common in Europe and Asia, United States use is largely confined to institutions where all utilities are under single ownership. Cut-and-cover transportation projects appear to display nearly ideal conditions for the use ...
Evolution of Space Station EMU PLSS technology recommendations
NASA Technical Reports Server (NTRS)
Wilde, Richard C.
1990-01-01
Viewgraphs on extravehicular mobility unit (EMU) portable life support system (PLSS) technology recommendations are presented. Topics covered include: oxygen supply storage; oxygen supply regulators; carbon dioxide control; prime movers; crew comfort; heat rejection; power sources; controls; display devices; and sensor technology.
Diazobenzene-containing conjugated polymers as dark quenchers.
Wu, Jiatao; Tan, Ying; Xie, Yonghua; Wu, Yi; Zhao, Rui; Jiang, Yuyang; Tan, Chunyan
2013-12-18
The synthesis and photophysical characterization of new conjugated polymers (CPs) with alternating phenylethynylene and diazobenzene (azo-PPE) units were reported, which showed broadened absorption and no measurable fluorescence. Quenching studies showed that azo-PPEs displayed high efficiency over a wide wavelength range.
2000-10-26
This plaque, displayed on the grounds of Marshall Space Flight Center in Huntsville, Alabama, commemorates the Saturn V Dynamic Test Stand as a National Historic Landmark. The site was designated as such in 1985 by the National Park Service of the United States Department of the Interior.
2000-10-26
This plaque, displayed on the grounds of Marshall Space Flight Center in Huntsville, Alabama, commemorates the Saturn V Launch Vehicle as a National Historic Landmark. The site was designated as such in 1984 by the National Park Service of the United States Department of the Interior.
2000-10-26
This plaque, displayed on the grounds of Marshall Space Flight Center in Huntsville, Alabama commemorates the Neutral Buoyancy Space Simulator as a National Historic Landmark. The site was designated as such in 1986 by the National Park Service of the United States Department of the Interior.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-10
...,'' imported from abroad for temporary exhibition within the United States, are of cultural significance. The... that the exhibition or display of the exhibit objects at the Institute for the Study of the Ancient...
Forest Statistics for Maine, 1995
Douglas M. Griffith; Carol L. Alerich; Carol L. Alerich
1996-01-01
A statistical report on the fourth forest inventory of Maine conducted in 1994-96. Findings are displayed in 117 tables containing estimates of forest area numbers of trees, timber volume, and growth. Data are presented at three levels: state, geographic unit, and county.
Evaluation of the ADAPTIR System for Work Zone Traffic Control
DOT National Transportation Integrated Search
1999-11-01
The ADAPTIR system (Automated Data Acquisition and Processing of Traffic Information in Real Time) uses variable message signs (VMS) equipped with radar units, along with a software program to interpret the data, to display appropriate warning and ad...
NASA Technical Reports Server (NTRS)
Steffen, Dale A. (Inventor); Sturm, Ronald E. (Inventor); Rinard, George A. (Inventor)
1981-01-01
A system is disclosed for monitoring vital physiological signs. Each of the system components utilizes a single hybrid circuit with each component having high accuracy without the necessity of repeated calibration. The system also has low power requirements, provides a digital display, and is of sufficiently small size to be incorporated into a hand-carried case for portable use. Components of the system may also provide independent outputs making the component useful, of itself, for monitoring one or more vital signs. The overall system preferably includes an ECG amplifier and cardiotachometer signal conditioner unit, an impedance pneumograph and respiration rate signal conditioner unit, a heart/breath rate processor unit, a temperature monitoring unit, a selector switch, a clock unit, and an LCD driver unit and associated LCDs, with the system being capable of being expanded as needed or desired, such as, for example, by addition of a systolic/diastolic blood pressure unit.
Preparation and Presentation of Digital Maps in Raster Format
Edwards, K.; Batson, R.M.
1980-01-01
A set of algorithms has been developed at USGS Flagstaff for displaying digital map data in raster format. The set includes: FILLIN, which assigns a specified attribute code to units of a map which have been outlined on a digitizer and converted to raster format; FILBND, which removes the outlines; ZIP, which adds patterns to the map units; and COLOR, which provides a simplified process for creating color separation plates for either photographic or lithographic reproduction. - Authors
Hierarchical Formation of Fibrillar and Lamellar Self-Assemblies from Guanosine-Based Motifs
Neviani, Paolo; Sarazin, Dominique; Schmutz, Marc; Blanck, Christian; Giuseppone, Nicolas; Spada, Gian Piero
2010-01-01
Here we investigate the supramolecular polymerizations of two lipophilic guanosine derivatives in chloroform by light scattering technique and TEM experiments. The obtained data reveal the presence of several levels of organization due to the hierarchical self-assembly of the guanosine units in ribbons that in turn aggregate in fibrillar or lamellar soft structures. The elucidation of these structures furnishes an explanation to the physical behaviour of guanosine units which display organogelator properties. PMID:20798860
A portable device for detecting fruit quality by diffuse reflectance Vis/NIR spectroscopy
NASA Astrophysics Data System (ADS)
Sun, Hongwei; Peng, Yankun; Li, Peng; Wang, Wenxiu
2017-05-01
Soluble solid content (SSC) is a major quality parameter to fruit, which has influence on its flavor or texture. Some researches on the on-line non-invasion detection of fruit quality were published. However, consumers desire portable devices currently. This study aimed to develop a portable device for accurate, real-time and nondestructive determination of quality factors of fruit based on diffuse reflectance Vis/NIR spectroscopy (520-950 nm). The hardware of the device consisted of four units: light source unit, spectral acquisition unit, central processing unit, display unit. Halogen lamp was chosen as light source. When working, its hand-held probe was in contact with the surface of fruit samples thus forming dark environment to shield the interferential light outside. Diffuse reflectance light was collected and measured by spectrometer (USB4000). ARM (Advanced RISC Machines), as central processing unit, controlled all parts in device and analyzed spectral data. Liquid Crystal Display (LCD) touch screen was used to interface with users. To validate its reliability and stability, 63 apples were tested in experiment, 47 of which were chosen as calibration set, while others as prediction set. Their SSC reference values were measured by refractometer. At the same time, samples' spectral data acquired by portable device were processed by standard normalized variables (SNV) and Savitzky-Golay filter (S-G) to eliminate the spectra noise. Then partial least squares regression (PLSR) was applied to build prediction models, and the best predictions results was achieved with correlation coefficient (r) of 0.855 and standard error of 0.6033° Brix. The results demonstrated that this device was feasible to quantitatively analyze soluble solid content of apple.
Emotional Labor in the Dual Role of Teaching and Coaching.
Lee, Ye Hoon; Chelladurai, Packianathan; Kang, Chanho
2017-01-01
This study investigated the emotional labor involved in two forms of sport services-teaching and coaching-as perceived by high school teacher-coaches regarding required emotional displays and the use of emotional labor strategies. A total of 403 high school teacher-coaches from 47 states in the United States completed the online questionnaires measuring their perceptions of required emotional displays and their uses of emotional labor strategies in the two occupational roles. Results showed that there was no significant difference in the perception of positive emotional displays as required among participants. However, participants perceived that the expressions of friendliness and cheerfulness were more required in teaching than in coaching. On the other side, negative emotional displays were perceived to be more required in coaching than in teaching. That is, expressing upset, disappointment, anger, unhappiness, and frustration were perceived differently among participants. Also, participants utilized more surface acting when teaching and employed more genuine expression when coaching. The findings of this study highlight that differences do exist in the perception of required emotional displays and the utilization of emotional labor strategies in the two roles of teaching and coaching. These results were discussed in light of the task and group differences between teaching and coaching.
27 CFR 555.125 - Records maintained by permittees.
Code of Federal Regulations, 2011 CFR
2011-04-01
...; (iii) Manufacturer's marks of identification; (iv) Quantity (applicable quantity units, such as pounds... (dyn), blasting agents (ba), detonators (det), display fireworks (df), etc., and size (length and... nonlicensees or nonpermittees as prescribed in § 555.126. (5) The regional director (compliance) may authorize...
27 CFR 555.125 - Records maintained by permittees.
Code of Federal Regulations, 2010 CFR
2010-04-01
...; (iii) Manufacturer's marks of identification; (iv) Quantity (applicable quantity units, such as pounds... (dyn), blasting agents (ba), detonators (det), display fireworks (df), etc., and size (length and... nonlicensees or nonpermittees as prescribed in § 555.126. (5) The regional director (compliance) may authorize...
Code of Federal Regulations, 2014 CFR
2014-04-01
... ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United States-Peru Trade Promotion Agreement... natural resources not included in paragraphs (g)(1) through (g)(4) of this section that are extracted or...; banners; marketing displays; free samples; sales, marketing, and after-sales service literature (product...
Code of Federal Regulations, 2014 CFR
2014-04-01
... ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United States-Colombia Trade Promotion... natural resources not included in paragraphs (g)(1) through (g)(4) of this section that are extracted or... conferences, trade shows and conventions; banners; marketing displays; free samples; sales, marketing, and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Definitions. 23.701... DRUG-FREE WORKPLACE Contracting for Environmentally Preferable Products and Services 23.701 Definitions. As used in this subpart— Computer monitor means a video display unit used with a computer. Desktop...
Tools for a Document Image Utility.
ERIC Educational Resources Information Center
Krishnamoorthy, M.; And Others
1993-01-01
Describes a project conducted at Rensselaer Polytechnic Institute (New York) that developed methods for automatically subdividing pages from technical journals into smaller semantic units for transmission, display, and further processing in an electronic environment. Topics discussed include optical scanning and image compression, digital image…
NASA Technical Reports Server (NTRS)
Cash, B.
1985-01-01
Simple technique developed for monitoring direct currents up to several hundred amperes and digitally displaying values directly in current units. Used to monitor current magnitudes beyond range of standard laboratory ammeters, which typically measure 10 to 20 amperes maximum. Technique applicable to any current-monitoring situation.
2000-10-16
This plaque, displayed on the grounds of Marshall Space Flight Center in Huntsville, Alabama, commemorates the designation of the Propulsion and Structural Test Facility as a National Historic Landmark by the National Park Service of the United States Interior. The site was designated as a landmark in 1985.
Official portrait of astronaut Bryan D. O'Connor
NASA Technical Reports Server (NTRS)
1990-01-01
Official portrait of Bryan D. O'Connor, United States Marine Corps (USMC) Colonel, member of Astronaut Class 9 (1980), and space shuttle commander. O'Connor wears a launch and entry suit (LES) with his helmet displayed on table in front of him.
The Analog Computer as a Teaching Tool in Physics
ERIC Educational Resources Information Center
Wylen, H. E.; Schwarz, W. M.
1973-01-01
Discusses use of two EAI semi-expanded TR-20 units to display solutions to differential equations for harmonic oscillators, quantum-mechanical particles, trajectories, radioactive decay series, and hysteresis curves. Suggests practical applications for both undergraduate physics laboratories and classroom demonstrations. (CC)
... history of nurses and nursing in relation to domestic violence and related research. Activists and reformers in the United States have long recognized the harm of domestic violence and sought to improve the lives of women ...
Data processing for water monitoring system
NASA Technical Reports Server (NTRS)
Monford, L.; Linton, A. T.
1978-01-01
Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.
Forest Statistics for Kentucky - 1975 and 1988
Carol L. Alerich
1990-01-01
A statistical report on the fourth forest survey of Kentucky (1988). Findings are displayed in 204 tables containing estimates of forest area, number of trees, timber volume, tree biomass, and timber products output. Data are presented at three levels: state, geographic unit, and county.
Forest statistics for Maryland--1976 and 1986
Thomas S. Frieswyk; Dawn M. DiGiovanni; Dawn M. DiGiovanni
1988-01-01
A statistical report on the fourth forest survey of Maryland (1986). Findings are displayed in 115 tables containing estimates of forest area, numbers of trees, timber volume, tree biomass, and timber products output. Data are presented at three levels: state, geographic unit, and county.
Remote Software Application and Display Development
NASA Technical Reports Server (NTRS)
Sanders, Brandon T.
2014-01-01
The era of the shuttle program has come to an end, but only to give rise to newer and more exciting projects. Now is the time of the Orion spacecraft, a work of art designed to exceed all previous endeavors of man. NASA is exiting the time of exploration and is entering a new period, a period of pioneering. With this new mission, many of NASAs organizations must undergo a great deal of change and development to support the Orion missions. The Spaceport Command and Control System (SCCS) is the new system that will provide NASA the ability to launch rockets into orbit and thus control Orion and other spacecraft as the goal of populating Mars becomes ever increasingly tangible. Since the previous control system, Launch Processing System (LPS), was primarily designed to launch the shuttles, SCCS was needed as Kennedy Space Center (KSC) reorganized to a multiuser spaceport for commercial flights, providing a more versatile control over rockets. Within SCCS, is the Launch Control System (LCS), which is the remote software behind the command and monitoring of flight and ground system hardware. This internship at KSC has involved two main components in LCS, including Remote Software Application and Display development. The display environment provides a graphical user interface for an operator to view and see if any cautions are raised, while the remote applications are the backbone that communicate with hardware, and then relay the data back to the displays. These elements go hand in hand as they provide monitoring and control over hardware and software alike from the safety of the Launch Control Center. The remote software applications are written in Application Control Language (ACL), which must undergo unit testing to ensure data integrity. This paper describes both the implementation and writing of unit tests in ACL code for remote software applications, as well as the building of remote displays to be used in the Launch Control Center (LCC).
Synthesis of tumor necrosis factor α for use as a mirror-image phage display target.
Petersen, Mark E; Jacobsen, Michael T; Kay, Michael S
2016-06-21
Tumor Necrosis Factor alpha (TNFα) is an inflammatory cytokine that plays a central role in the pathogenesis of chronic inflammatory disease. Here we describe the chemical synthesis of l-TNFα along with the mirror-image d-protein for use as a phage display target. The synthetic strategy utilized native chemical ligation and desulfurization to unite three peptide segments, followed by oxidative folding to assemble the 52 kDa homotrimeric protein. This synthesis represents the foundational step for discovering an inhibitory d-peptide with the potential to improve current anti-TNFα therapeutic strategies.
Building stones of our Nation's Capital
Withington, Charles F.
1975-01-01
The buildings of our Nation's Capital serve as an unusual geologic display, for the city has been constructed with rocks from quarries throughout the United States and many distant lands. Each building is a unique museum that not only displays the important features of various stones and the geologic environment in which they were formed, but also serves as an historic witness to the city's growth and to the development of its architecture. This booklet describes the source and appearance of the stones used in Washington, D.C.; it includes a map and a walking guide to assist the visitor in examining them.
Use of videotape for off-line viewing of computer-assisted radionuclide cardiology studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thrall, J.H.; Pitt, B.; Marx, R.S.
1978-02-01
Videotape offers an inexpensive method for off-line viewing of dynamic radionuclide cardiac studies. Two approaches to videotaping have been explored and demonstrated to be feasible. In the first, a video camera in conjunction with a cassette-type recorder is used to record from the computer display scope. Alternatively, for computer systems already linked to video display units, the video signal can be routed directly to the recorder. Acceptance and use of tracer cardiology studies will be enhanced by increased availability of the studies for clinical review. Videotape offers an inexpensive flexible means of achieving this.
1981-07-01
Figure Page I OORAN’ Transmitting Antenna Located at FS 517 on Fuselage Under- 4 surface of Gulfstream I Airplane 2 CORAN ’" Receiving Antenna Pair...Located at FS 376.5 on Fuselage 5 Undersurface of Gulfstream 1 Airplane 3 CORAN ’ Rack Installed in Gulfstream I Airplane 7 4 CORAN " Power and Display...Unit 8 5 CORAN ’" Velocity Concept 9 6 Correlation Geometry in a Drift 11 7 Pitch and Roll Insensitivity 11 iv INTRODUCTION A groundspeed display, to be
The UCSC genome browser: what every molecular biologist should know.
Mangan, Mary E; Williams, Jennifer M; Kuhn, Robert M; Lathe, Warren C
2009-10-01
Electronic data resources can enable molecular biologists to query and display many useful features that make benchwork more efficient and drive new discoveries. The UCSC Genome Browser provides a wealth of data and tools that advance one's understanding of genomic context for many species, enable detailed understanding of data, and provide the ability to interrogate regions of interest. Researchers can also supplement the standard display with their own data to query and share with others. Effective use of these resources has become crucial to biological research today, and this unit describes some practical applications of the UCSC Genome Browser.
The Pluto system: Initial results from its exploration by New Horizons.
Stern, S A; Bagenal, F; Ennico, K; Gladstone, G R; Grundy, W M; McKinnon, W B; Moore, J M; Olkin, C B; Spencer, J R; Weaver, H A; Young, L A; Andert, T; Andrews, J; Banks, M; Bauer, B; Bauman, J; Barnouin, O S; Bedini, P; Beisser, K; Beyer, R A; Bhaskaran, S; Binzel, R P; Birath, E; Bird, M; Bogan, D J; Bowman, A; Bray, V J; Brozovic, M; Bryan, C; Buckley, M R; Buie, M W; Buratti, B J; Bushman, S S; Calloway, A; Carcich, B; Cheng, A F; Conard, S; Conrad, C A; Cook, J C; Cruikshank, D P; Custodio, O S; Dalle Ore, C M; Deboy, C; Dischner, Z J B; Dumont, P; Earle, A M; Elliott, H A; Ercol, J; Ernst, C M; Finley, T; Flanigan, S H; Fountain, G; Freeze, M J; Greathouse, T; Green, J L; Guo, Y; Hahn, M; Hamilton, D P; Hamilton, S A; Hanley, J; Harch, A; Hart, H M; Hersman, C B; Hill, A; Hill, M E; Hinson, D P; Holdridge, M E; Horanyi, M; Howard, A D; Howett, C J A; Jackman, C; Jacobson, R A; Jennings, D E; Kammer, J A; Kang, H K; Kaufmann, D E; Kollmann, P; Krimigis, S M; Kusnierkiewicz, D; Lauer, T R; Lee, J E; Lindstrom, K L; Linscott, I R; Lisse, C M; Lunsford, A W; Mallder, V A; Martin, N; McComas, D J; McNutt, R L; Mehoke, D; Mehoke, T; Melin, E D; Mutchler, M; Nelson, D; Nimmo, F; Nunez, J I; Ocampo, A; Owen, W M; Paetzold, M; Page, B; Parker, A H; Parker, J W; Pelletier, F; Peterson, J; Pinkine, N; Piquette, M; Porter, S B; Protopapa, S; Redfern, J; Reitsema, H J; Reuter, D C; Roberts, J H; Robbins, S J; Rogers, G; Rose, D; Runyon, K; Retherford, K D; Ryschkewitsch, M G; Schenk, P; Schindhelm, E; Sepan, B; Showalter, M R; Singer, K N; Soluri, M; Stanbridge, D; Steffl, A J; Strobel, D F; Stryk, T; Summers, M E; Szalay, J R; Tapley, M; Taylor, A; Taylor, H; Throop, H B; Tsang, C C C; Tyler, G L; Umurhan, O M; Verbiscer, A J; Versteeg, M H; Vincent, M; Webbert, R; Weidner, S; Weigle, G E; White, O L; Whittenburg, K; Williams, B G; Williams, K; Williams, S; Woods, W W; Zangari, A M; Zirnstein, E
2015-10-16
The Pluto system was recently explored by NASA's New Horizons spacecraft, making closest approach on 14 July 2015. Pluto's surface displays diverse landforms, terrain ages, albedos, colors, and composition gradients. Evidence is found for a water-ice crust, geologically young surface units, surface ice convection, wind streaks, volatile transport, and glacial flow. Pluto's atmosphere is highly extended, with trace hydrocarbons, a global haze layer, and a surface pressure near 10 microbars. Pluto's diverse surface geology and long-term activity raise fundamental questions about how small planets remain active many billions of years after formation. Pluto's large moon Charon displays tectonics and evidence for a heterogeneous crustal composition; its north pole displays puzzling dark terrain. Small satellites Hydra and Nix have higher albedos than expected. Copyright © 2015, American Association for the Advancement of Science.
NASA Astrophysics Data System (ADS)
Milanovic, Veljko; Kasturi, Abhishek; Hachtel, Volker
2015-02-01
A high brightness Head-Up Display (HUD) module was demonstrated with a fast, dual-axis MEMS mirror that displays vector images and text, utilizing its ~8kHz bandwidth on both axes. Two methodologies were evaluated: in one, the mirror steers a laser at wide angles of <48° on transparent multi-color fluorescent emissive film and displays content directly on the windshield, and in the other the mirror displays content on reflective multi-color emissive phosphor plates reflected off the windshield to create a virtual image for the driver. The display module is compact, consisting of a single laser diode, off-the-shelf lenses and a MEMS mirror in combination with a MEMS controller to enable precise movement of the mirror's X- and Y-axis. The MEMS controller offers both USB and wireless streaming capability and we utilize a library of functions on a host computer for creating content and controlling the mirror. Integration with smart phone applications is demonstrated, utilizing the mobile device both for content generation based on various messages or data, and for content streaming to the MEMS controller via Bluetooth interface. The display unit is highly resistant to vibrations and shock, and requires only ~1.5W to operate, even with content readable in sunlit outdoor conditions. The low power requirement is in part due to a vector graphics approach, allowing the efficient use of laser power, and also due to the use of a single, relatively high efficiency laser and simple optics.
Environmental qualification of the MH-53J color multifunction display
NASA Astrophysics Data System (ADS)
Malia, Timothy E.
1996-05-01
In early 1994, Loral Federal Systems Owego (LFS-O) was awarded the MH-53J Interactive Defensive Avionics System/Multi-Mission Advanced Tactical Terminal (IDAS/MATT) upgrade program as prime contractor. The MH-53J is a USAF special operations helicopter providing infiltration and exfiltration mission capability in a low-slow manner. One element the upgrade was a new digital map system (DMS), which consists of a 2 GB digital memory unit (DMU), a digital map computer (DMC) and a 6' by 8' color multi-function display (CMFD). Although the original specification was written for a CRT, Loral determined that an active matrix liquid crystal display (AMLCD) based solution would better achieve the mission goals. The display upgrade was not intended to be a development program, but LFS-O found that there were very few solutions available near term, and chose to develop the display in Owego, making it their first military AMLCD production program. The CMFD is based on a commercial liquid crystal display manufactured by Display Technologies Incorporated (DTI), a joint venture of IBM and Toshiba. In March of 1995, just nine months after the design started, LFS-O delivered the first CMFD for systems integration. In December 1995, LFS-O successfully completed the environmental qualification of the CMFD. The extensive testing unearthed several initial deficiencies in the thermal, vibration, humidity salt fog and EMI design. This paper discusses these challenges and how they were overcome to achieve compliance with the USAF requirements.
Topographic and hydraulic controls over alluviation on a bedrock template
NASA Astrophysics Data System (ADS)
Milan, David; Heritage, George; Entwistle, Neil; Tooth, Stephen
2017-04-01
Bedrock-alluvial anastomosed channels found in dryland rivers are characterised by an over-wide channel cut into the host rock containing a network of interconnecting bedrock sub-channels separated by bedrock influenced interfluve areas. Whilst the channels remain largely free of sediment the interfluves display varying levels of alluviation ranging from bare rock, sand sheets and silt drapes through to consolidated bedrock core bars, islands and lateral deposits. Examination of the sedimentary units associated with the bedrock anastomosed reaches of the Sabie river in the Kruger National Park, South Africa reveal a repeating sequence of coarse sand / fine gravel grading through to silt representing successive flood related depositional units. Unit development in relation to the bedrock template was investigated using pre-flood aerial imagery of bedrock core bar locations and post flood LiDAR data of bedrock anastomosed sites stripped during the 2000 and 2012 extreme flood events. This revealed a propensity for bar development associated with bedrock hollows disconnected from the principal high-energy sub-channels. 2-D morpho-dynamic modelling was used to further investigate spatial patterns of deposition over the bedrock template. Although topographic lows displayed mid-range velocities during peak flow events, these are likely to be preferential routing areas, with sediments stalling in low energy areas on the falling limb of floods. It is also likely that vegetation development plays a fundamental role in the development of alluviated zones, through increasing strength of alluvial units and capturing new sediments. With these results in mind we present a conceptual model for the development of bedrock-core bars, the fundamental unit in bedrock-alluvial anastomosed channels.
Specifications Physiological Monitoring System
NASA Technical Reports Server (NTRS)
1985-01-01
The operation of a physiological monitoring system (PMS) is described. Specifications were established for performance, design, interface, and test requirements. The PMS is a compact, microprocessor-based system, which can be worn in a pack on the body or may be mounted on a Spacelab rack or other appropriate structure. It consists of two modules, the Data Control Unit (DCU) and the Remote Control/Display Unit (RCDU). Its purpose is to collect and distribute data from physiological experiments in the Spacelab and in the Orbiter.
2006-10-03
Ames and Moffett Field (MFA) historical sites and memorials Unitary Plan Wind Tunned plaza; display and historical site plaques with the NASA logo on the Wind Tunnel valve as a backdrop. Plaque depicts that Ames Unitary Plan Wind Tunnel has been designated a National Historic Landmark by the National Park Service, United States Department of the Interior 1985 The plaque reads; This site possesses national significance in commemorating the history of the United States of America. That ceremony took place on September 12, 1990
Manned maneuvering unit technology survey
NASA Technical Reports Server (NTRS)
Cook, G. V. O. (Editor)
1975-01-01
The preliminary design of the manned maneuvering unit (MMU) for the shuttle is investigated, and the current state of the art in certain technology areas that may find application on the operational EVA shuttle MMU is examined. Three broad areas of technology, namely: (1) mechanical energy storage - i.e., the practicality of utilizing the energy storage capability of either a reaction wheel or a control moment gyro, (2) numerical and alphanumerical displays, and (3) recent electronics developments such as microprocessors and integrated injection logic, were covered.
NASA Technical Reports Server (NTRS)
Carl, J. G.; Furukawa, S.
1975-01-01
A manual is presented that provides basic technical documentation to support the operation and utilization of the Portable Ambulance Module (PAM) in the field. The PAM is designed to be used for emergency resuscitation and victim monitoring. The functions of all the controls, displays, and stowed equipment of the unit are defined. Supportive medical and physiological data in those areas directly related to the uses of the PAM unit are presented.
Computer-aided boundary delineation of agricultural lands
NASA Technical Reports Server (NTRS)
Cheng, Thomas D.; Angelici, Gary L.; Slye, Robert E.; Ma, Matt
1989-01-01
The National Agricultural Statistics Service of the United States Department of Agriculture (USDA) presently uses labor-intensive aerial photographic interpretation techniques to divide large geographical areas into manageable-sized units for estimating domestic crop and livestock production. Prototype software, the computer-aided stratification (CAS) system, was developed to automate the procedure, and currently runs on a Sun-based image processing system. With a background display of LANDSAT Thematic Mapper and United States Geological Survey Digital Line Graph data, the operator uses a cursor to delineate agricultural areas, called sampling units, which are assigned to strata of land-use and land-cover types. The resultant stratified sampling units are used as input into subsequent USDA sampling procedures. As a test, three counties in Missouri were chosen for application of the CAS procedures. Subsequent analysis indicates that CAS was five times faster in creating sampling units than the manual techniques were.
27 CFR 555.124 - Records maintained by licensed dealers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... following the date of purchase or other acquisition of explosive materials (except as provided in paragraph... identification. (4) Quantity (applicable quantity units, such as pounds of explosives, number of detonators, number of display fireworks, etc.). (5) Description (dynamite (dyn), blasting agents (ba), detonators...
27 CFR 555.124 - Records maintained by licensed dealers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... following the date of purchase or other acquisition of explosive materials (except as provided in paragraph... identification. (4) Quantity (applicable quantity units, such as pounds of explosives, number of detonators, number of display fireworks, etc.). (5) Description (dynamite (dyn), blasting agents (ba), detonators...
The Committee on Foreign Investment in the United States (CFIUS)
2006-04-24
2 The “Exon- Florio ” Provision... Florio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Impact of the Exon- Florio Process on CFIUS...amend the CFIUS process; and those that would amend the Exon- Florio process (explained below). Six bills focus primarily on CFIUS and display a range of
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
21 CFR 880.2910 - Clinical electronic thermometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Clinical electronic thermometer. 880.2910 Section... Monitoring Devices § 880.2910 Clinical electronic thermometer. (a) Identification. A clinical electronic... with an electronic signal amplification, conditioning, and display unit. The transducer may be in a...
Factors Affecting Successful Reintegration
ERIC Educational Resources Information Center
Thomas, David Vittle
2015-01-01
This study explores the perspectives of education practitioners towards the process of reintegrating pupils (many of whom display social, emotional and behavioural difficulties), from a pupil referral unit (PRU) to mainstream educational provision in a rural bilingual Welsh authority, and examines the barriers and facilitators they identified as…
Forest statistics for Maryland: 1986 and 1999
Thomas S. Frieswyk
2001-01-01
A statistical report on the fifth forest inventory of Maryland (1998-1999). Findings are displayed in 109 tables containing estimates of forest area, numbers of trees, wildlife habitat, timber volume, growth, change, and biomass. Data are presented at three levels: state, geographic unit and county.
Forest statistics for Ohio, 1991
Douglas M. Griffith; Dawn M. DiGiovanni; Teresa L. Witzel; Eric H. Wharton
1993-01-01
A statistical report on the fourth forest inventory of Ohio conducted in 1988-90. Findings are displayed in tables containing estimates of forest area, number of trees, sawtimber volume, growing-stock volume, biomass, growth, and removals. Data are presented at three levels: state, geographic unit, and county.
Searching LOGIN, the Local Government Information Network.
ERIC Educational Resources Information Center
Jack, Robert F.
1984-01-01
Describes a computer-based information retrieval and electronic messaging system produced by Control Data Corporation now being used by government agencies and other organizations. Background of Local Government Information Network (LOGIN), database structure, types of LOGIN units, searching LOGIN (intersect, display, and list commands), and how…
47 CFR 79.103 - Closed caption decoder requirements for apparatus.
Code of Federal Regulations, 2014 CFR
2014-10-01
... RADIO SERVICES ACCESSIBILITY OF VIDEO PROGRAMMING Apparatus § 79.103 Closed caption decoder requirements... video programming transmitted simultaneously with sound, if such apparatus is manufactured in the United... with built-in closed caption decoder circuitry or capability designed to display closed-captioned video...
Climate change impacts on extreme events in the United States: an uncertainty analysis
Extreme weather and climate events, such as heat waves, droughts and severe precipitation events, have substantial impacts on ecosystems and the economy. However, future climate simulations display large uncertainty in mean changes. As a result, the uncertainty in future changes ...
Patterned Video Sensors For Low Vision
NASA Technical Reports Server (NTRS)
Juday, Richard D.
1996-01-01
Miniature video cameras containing photoreceptors arranged in prescribed non-Cartesian patterns to compensate partly for some visual defects proposed. Cameras, accompanied by (and possibly integrated with) miniature head-mounted video display units restore some visual function in humans whose visual fields reduced by defects like retinitis pigmentosa.
Forest statistics for West Virginia--1975 and 1989
Dawn M. Di Giovanni; Dawn M. Di Giovanni
1990-01-01
A statistical report on the fourth forest survey of West Virginia (1989). Findings are displayed in 119 tables containing estimates of forest area, number of trees, timber volume, tree biomass, and timber products output. Data are presented at three levels: state, geographic unit, and county.
A voice-actuated wind tunnel model leak checking system
NASA Technical Reports Server (NTRS)
Larson, William E.
1989-01-01
A computer program has been developed that improves the efficiency of wind tunnel model leak checking. The program uses a voice recognition unit to relay a technician's commands to the computer. The computer, after receiving a command, can respond to the technician via a voice response unit. Information about the model pressure orifice being checked is displayed on a gas-plasma terminal. On command, the program records up to 30 seconds of pressure data. After the recording is complete, the raw data and a straight line fit of the data are plotted on the terminal. This allows the technician to make a decision on the integrity of the orifice being checked. All results of the leak check program are stored in a database file that can be listed on the line printer for record keeping purposes or displayed on the terminal to help the technician find unchecked orifices. This program allows one technician to check a model for leaks instead of the two or three previously required.
NASA Astrophysics Data System (ADS)
Wang, Chongchen; Guo, Guangliang; Wang, Peng
2013-01-01
Two lanthanide based metal-organic frameworks, [NaLn(oba)(ox)(H2O)] (Lndbnd6 Eu(1) and Sm(2)) were obtained from 4,4'-oxybisbenzoic acid, sodium oxalate and corresponding lanthanide salts by hydrothermal synthesis. They were characterized by single-crystal X-ray diffraction, IR spectra, and photoluminescent spectra. The crystallographic data reveals that complexes 1 and 2 are isomorphous and isostructural, composed of three-dimensional framework built up of distorted tricapped trigonal EuO9 units, distorted octahedron NaO6 units, 4,4'-oxybis(benzoate) and oxalate. The carboxylate oxygen atoms of the 4,4'-oxybis(benzoate) and oxalate ligand are coordinated to lanthanide ions and sodium ions, resulting into two-dimensional inorganic sheets, which are further linked into three-dimensional network by organic ligands. Thermogravimetric analyses of 1-2 display a considerable thermal stability. Photoluminescent measurements indicated that europium complex 1 displayed strong red emission.
van Harreveld, Frenk; Gervais, Will; Schrag, Yann; Mohr, Christine; van Elk, Michiel
2017-01-01
The ability to mentalize has been marked as an important cognitive mechanism enabling belief in supernatural agents. In five studies we cross-culturally investigated the relationship between mentalizing and belief in supernatural agents with large sample sizes (over 67,000 participants in total) and different operationalizations of mentalizing. The relative importance of mentalizing for endorsing supernatural beliefs was directly compared with credibility enhancing displays–the extent to which people observed credible religious acts during their upbringing. We also compared autistic with neurotypical adolescents. The empathy quotient and the autism-spectrum quotient were not predictive of belief in supernatural agents in all countries (i.e., The Netherlands, Switzerland and the United States), although we did observe a curvilinear effect in the United States. We further observed a strong influence of credibility enhancing displays on belief in supernatural agents. These findings highlight the importance of cultural learning for acquiring supernatural beliefs and ask for reconsiderations of the importance of mentalizing. PMID:28832606
High Efficiency Stacked Organic Light-Emitting Diodes Employing Li2O as a Connecting Layer
NASA Astrophysics Data System (ADS)
Kanno, Hiroshi; Hamada, Yuji; Nishimura, Kazuki; Okumoto, Kenji; Saito, Nobuo; Ishida, Hiroki; Takahashi, Hisakazu; Shibata, Kenichi; Mameno, Kazunobu
2006-12-01
We demonstrate the high-efficiency stacked organic light-emitting diodes (OLEDs) introducing new connecting layers. In the green stacked OLEDs, the external efficiencies increase proportionally to the number of the stacked units without suffering the decrease in power efficiency. The current, power and external efficiencies at 0.5 mA/cm2 of the stacked OLED with six stacked units (6-stacked OLED) have reached 235 cd/A, 46.6 lm/W, and 65.8%, respectively. Furthermore, we have applied the connecting layers to a white stacked OLED and fabricated an active-matrix full-color display with a low temperature polysilicon thin film transistor backplane. In the device, the current efficiency of the white 2-stacked OLED is enhanced by a factor of 2.2. The initial luminance drop is significantly suppressed for the white 2-stacked OLED compared to 1-stacked OLED. The proposed white stacked OLED technology can be applied to a full-color display for a practical use.
The Effects of Immigration and Media Influence on Body Image Among Pakistani Men
Saghir, Sheeba; Hyland, Lynda
2017-01-01
This study examined the role of media influence and immigration on body image among Pakistani men. Attitudes toward the body were compared between those living in Pakistan (n = 56) and those who had immigrated to the United Arab Emirates (n = 58). Results of a factorial analysis of variance demonstrated a significant main effect of immigrant status. Pakistani men living in the United Arab Emirates displayed poorer body image than those in the Pakistan sample. Results also indicated a second main effect of media influence.Those highly influenced by the media displayed poorer body image. No interaction effect was observed between immigrant status and media influence on body image. These findings suggest that media influence and immigration are among important risk factors for the development of negative body image among non-Western men. Interventions designed to address the negative effects of the media and immigration may be effective at reducing body image disorders and other related health problems in this population. PMID:28625116
The Effects of Immigration and Media Influence on Body Image Among Pakistani Men.
Saghir, Sheeba; Hyland, Lynda
2017-07-01
This study examined the role of media influence and immigration on body image among Pakistani men. Attitudes toward the body were compared between those living in Pakistan ( n = 56) and those who had immigrated to the United Arab Emirates ( n = 58). Results of a factorial analysis of variance demonstrated a significant main effect of immigrant status. Pakistani men living in the United Arab Emirates displayed poorer body image than those in the Pakistan sample. Results also indicated a second main effect of media influence.Those highly influenced by the media displayed poorer body image. No interaction effect was observed between immigrant status and media influence on body image. These findings suggest that media influence and immigration are among important risk factors for the development of negative body image among non-Western men. Interventions designed to address the negative effects of the media and immigration may be effective at reducing body image disorders and other related health problems in this population.
An Explanation Facility for the ROSIE (Tradename) Knowledge Engineering Language
1986-09-01
Caster supported by ’the Office of the Secretary of Defense. Centra« No- MDA «äSU^C-0080; «ad by TK» RAND CÄposaüß« «a part of its program of public...dsatmatioa: (1] If the «nit is « vend, deny that «aft is docked at that unit’s location sod assert tact unit is docked et the destination J2J If the unit... tMt ’ :aniwcra ’■ the, question, "What an you, doing now?" a graphical display window that answers the question, "Where are you in the cal
Endovascular Treatment in Emergency Setting of Acute Arterial Injuries After Orthopedic Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carrafiello, Gianpaolo, E-mail: gcarraf@tin.it; Fontana, Federico, E-mail: fede.fontana@libero.it; Mangini, Monica, E-mail: monica.mangini@tin.it
Purpose: To assess the feasibility and effectiveness of emergency endovascular treatment of acute arterial injuries after orthopedic surgery. Materials and Methods: Fifteen patients (mean age 68.3 years) with acute arterial injuries after orthopedic surgery were observed, in particular, 5 patients with pseudoaneurysm, 9 patients with active bleeding, and 1 patient with arterial dissection. Transarterial embolization (TAE) and positioning of covered and noncovered stents were the treatments performed. Follow-up after stent implantation (mean 36 months) was performed with color Doppler US (CDU) at 1, 3, 6, and 12 months and yearly thereafter. Plain X-ray was performed to evidence dislodgment or fracturemore » of the graft. A minimum of 12 months' follow-up is available after TAE. Results: Immediate technical success was obtained in all cases. No major complications occurred. Overall clinical success rate was 100%. During mean follow-up, stent-graft occlusions did not occurred. No recurrence and/or consequence of TAE was registered during a minimum follow-up of 12 months. Conclusions: Percutaneous treatment is a feasible and safe tool for treating arterial injuries because it can provide fast and definitive resolution of the damage. This low-invasiveness approach can be proposed as first-line treatment in patients with acute injuries after orthopedic surgery.« less
NASA Astrophysics Data System (ADS)
Cava, Daniela; Katul, Gabriel G.
2008-03-01
Using synchronous multi-level high frequency velocity measurements, the turbulence spectra within the trunk space of an alpine hardwood forest were analysed. The spectral short-circuiting of the energy cascade for each velocity component was well reproduced by a simplified spectral model that retained return-to-isotropy and component-wise work done by turbulence against the drag and wake production. However, the use of an anisotropic drag coefficient was necessary to reproduce these measured component-wise spectra. The degree of anisotropy in the vertical drag was shown to vary with the element Reynolds number. The wake production frequency in the measured spectra was shown to be consistent with the vortex shedding frequency at constant Strouhal number given by f vs = 0.21 ū/d, where d can be related to the stem diameter at breast height ( dbh) and ū is the local mean velocity. The energetic scales, determined from the inflection point instability at the canopy atmosphere interface, appear to persist into the trunk space when {C_{du} a_{cr} h_c /β ≫ 1}, where C du is the longitudinal drag coefficient, a cr is the crown-layer leaf area density, h c is the canopy height, and β is the dimensionless momentum absorption at the canopy top.
Pattern uniformity control in integrated structures
NASA Astrophysics Data System (ADS)
Kobayashi, Shinji; Okada, Soichiro; Shimura, Satoru; Nafus, Kathleen; Fonseca, Carlos; Biesemans, Serge; Enomoto, Masashi
2017-03-01
In our previous paper dealing with multi-patterning, we proposed a new indicator to quantify the quality of final wafer pattern transfer, called interactive pattern fidelity error (IPFE). It detects patterning failures resulting from any source of variation in creating integrated patterns. IPFE is a function of overlay and edge placement error (EPE) of all layers comprising the final pattern (i.e. lower and upper layers). In this paper, we extend the use cases with Via in additional to the bridge case (Block on Spacer). We propose an IPFE budget and CD budget using simple geometric and statistical models with analysis of a variance (ANOVA). In addition, we validate the model with experimental data. From the experimental results, improvements in overlay, local-CDU (LCDU) of contact hole (CH) or pillar patterns (especially, stochastic pattern noise (SPN)) and pitch walking are all critical to meet budget requirements. We also provide a special note about the importance of the line length used in analyzing LWR. We find that IPFE and CD budget requirements are consistent to the table of the ITRS's technical requirement. Therefore the IPFE concept can be adopted for a variety of integrated structures comprising digital logic circuits. Finally, we suggest how to use IPFE for yield management and optimization requirements for each process.
Augmented reality 3D display based on integral imaging
NASA Astrophysics Data System (ADS)
Deng, Huan; Zhang, Han-Le; He, Min-Yang; Wang, Qiong-Hua
2017-02-01
Integral imaging (II) is a good candidate for augmented reality (AR) display, since it provides various physiological depth cues so that viewers can freely change the accommodation and convergence between the virtual three-dimensional (3D) images and the real-world scene without feeling any visual discomfort. We propose two AR 3D display systems based on the theory of II. In the first AR system, a micro II display unit reconstructs a micro 3D image, and the mciro-3D image is magnified by a convex lens. The lateral and depth distortions of the magnified 3D image are analyzed and resolved by the pitch scaling and depth scaling. The magnified 3D image and real 3D scene are overlapped by using a half-mirror to realize AR 3D display. The second AR system uses a micro-lens array holographic optical element (HOE) as an image combiner. The HOE is a volume holographic grating which functions as a micro-lens array for the Bragg-matched light, and as a transparent glass for Bragg mismatched light. A reference beam can reproduce a virtual 3D image from one side and a reference beam with conjugated phase can reproduce the second 3D image from other side of the micro-lens array HOE, which presents double-sided 3D display feature.
Vasan, S N Swetadri; Ionita, Ciprian N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S
2012-02-23
We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.
An ethogram for Benthic Octopods (Cephalopoda: Octopodidae).
Mather, Jennifer A; Alupay, Jean S
2016-05-01
The present paper constructs a general ethogram for the actions of the flexible body as well as the skin displays of octopuses in the family Octopodidae. The actions of 6 sets of structures (mantle-funnel, arms, sucker-stalk, skin-web, head, and mouth) combine to produce behavioral units that involve positioning of parts leading to postures such as the flamboyant, movements of parts of the animal with relation to itself including head bob and grooming, and movements of the whole animal by both jetting in the water and crawling along the substrate. Muscular actions result in 4 key changes in skin display: (a) chromatophore expansion, (b) chromatophore contraction resulting in appearance of reflective colors such as iridophores and leucophores, (c) erection of papillae on the skin, and (d) overall postures of arms and mantle controlled by actions of the octopus muscular hydrostat. They produce appearances, including excellent camouflage, moving passing cloud and iridescent blue rings, with only a few known species-specific male visual sexual displays. Commonalities across the family suggest that, despite having flexible muscular hydrostat movement systems producing several behavioral units, simplicity of production may underlie the complexity of movement and appearance. This systematic framework allows researchers to take the next step in modeling how such diversity can be a combination of just a few variables. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-13
... the same by reason of infringement of various claims of United States Patent Nos. 6,281,955; 7,697,093... Mobility LLC of Atlanta, Georgia; Best Buy Stores, L.P. of Richfield, Minnesota; BestBuy.com , LLC of Eden...