ERIC Educational Resources Information Center
Yeung, Brendan; Ng, Tuck Wah; Tan, Han Yen; Liew, Oi Wah
2012-01-01
The use of different types of stains in the quantification of proteins separated on gels using electrophoresis offers the capability of deriving good outcomes in terms of linear dynamic range, sensitivity, and compatibility with specific proteins. An inexpensive, simple, and versatile lighting system based on liquid crystal display backlighting is…
Linear perspective limitations on virtual reality and realistic displays
NASA Astrophysics Data System (ADS)
Temme, Leonard A.
2007-04-01
The visual images of the natural world, with their immediate intuitive appeal, seem like the logical gold standard for evaluating displays. After all, since photorealistic displays look so increasingly like the real world, what could be better? Part of the shortcoming of this intuitive appeal for displays is its naivete. Realism itself is full of potential illusions that we do not notice because, most of the time, realism is good enough for our everyday tasks. But when confronted with tasks that go beyond those for which our visual system has evolved, we may be blindsided. If we survive, blind to our erroneous perceptions and oblivious to our good fortune at having survived, we will not be any wiser next time. Realist displays depend on linear perspective (LP), the mathematical mapping of three dimensions onto two. Despite the fact that LP is a seductively elegant system that predicts results with defined mathematical procedures, artists do not stick to the procedures, not because they are math-phobic but because LP procedures, if followed explicitly, produce ugly, limited, and distorted images. If artists bother with formal LP procedures at all, they invariably temper the renderings by eye. The present paper discusses LP assumptions, limitations, and distortions. It provides examples of kluges to cover some of these LP shortcomings. It is important to consider the limitations of LP so that we do not let either naive assumptions or the seductive power of LP guide our thinking or expectations unrealistically as we consider its possible uses in advanced visual displays.
Black phosphorus nanosheets for rapid microRNA detection.
Zhou, Jie; Li, Zhongjun; Ying, Ming; Liu, Maixian; Wang, Xiaomei; Wang, Xianyou; Cao, Liwei; Zhang, Han; Xu, Gaixia
2018-03-15
Herein, for the first time, a sensitive sensing platform for rapid detection of microRNA was developed by employing black phosphorus nanosheets as the fluorescence quenching material. The biosensor displayed a good linear response to microRNA ranging from 10 nM to 1000 nM. Moreover, the biosensor could distinguish triple nucleotide polymorphism.
Plastic scintillation detectors for dose monitoring in digital breast tomosynthesis
NASA Astrophysics Data System (ADS)
Antunes, J.; Machado, J.; Peralta, L.; Matela, N.
2018-01-01
Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat tomograph for two different peak kilovoltages: 26 kV and 35 kV. Both PSD displayed good linearity for each energy considered and almost no energy dependence.
NASA Astrophysics Data System (ADS)
Han, Lei; Liu, Pei; Petrenko, Valery A.; Liu, Aihua
2016-02-01
One of the major challenges in the design of biosensors for cancer diagnosis is to introduce a low-cost and selective probe that can recognize cancer cells. In this paper, we combined the phage display technology and electrochemical impedance spectroscopy (EIS) to develop a label-free cytosensor for the detection of cancer cells, without complicated purification of recognition elements. Fabrication steps of the cytosensing interface were monitored by EIS. Due to the high specificity of the displayed octapeptides and avidity effect of their multicopy display on the phage scaffold, good biocompatibility of recombinant phage, the fibrous nanostructure of phage, and the inherent merits of EIS technology, the proposed cytosensor demonstrated a wide linear range (2.0 × 102 - 2.0 × 108 cells mL-1), a low limit of detection (79 cells mL-1, S/N = 3), high specificity, good inter-and intra-assay reproducibility and satisfactory storage stability. This novel cytosensor designing strategy will open a new prospect for rapid and label-free electrochemical platform for tumor diagnosis.
Visual effects in great bowerbird sexual displays and their implications for signal design.
Endler, John A; Gaburro, Julie; Kelley, Laura A
2014-05-22
It is often assumed that the primary purpose of a male's sexual display is to provide information about quality, or to strongly stimulate prospective mates, but other functions of courtship displays have been relatively neglected. Male great bowerbirds (Ptilonorhynchus nuchalis) construct bowers that exploit the female's predictable field of view (FOV) during courtship displays by creating forced perspective illusions, and the quality of illusion is a good predictor of mating success. Here, we present and discuss two additional components of male courtship displays that use the female's predetermined viewpoint: (i) the rapid and diverse flashing of coloured objects within her FOV and (ii) chromatic adaptation of the female's eyes that alters her perception of the colour of the displayed objects. Neither is directly related to mating success, but both are likely to increase signal efficacy, and may also be associated with attracting and holding the female's attention. Signal efficacy is constrained by trade-offs between the signal components; there are both positive and negative interactions within multicomponent signals. Important signal components may have a threshold effect on fitness rather than the often assumed linear relationship.
High-resolution laser-projection display system using a grating electromechanical system (GEMS)
NASA Astrophysics Data System (ADS)
Brazas, John C.; Kowarz, Marek W.
2004-01-01
Eastman Kodak Company has developed a diffractive-MEMS spatial-light modulator for use in printing and display applications, the grating electromechanical system (GEMS). This modulator contains a linear array of pixels capable of high-speed digital operation, high optical contrast, and good efficiency. The device operation is based on deflection of electromechanical ribbons suspended above a silicon substrate by a series of intermediate supports. When electrostatically actuated, the ribbons conform to the supporting substructure to produce a surface-relief phase grating over a wide active region. The device is designed to be binary, switching between a reflective mirror state having suspended ribbons and a diffractive grating state having ribbons in contact with substrate features. Switching times of less than 50 nanoseconds with sub-nanosecond jitter are made possible by reliable contact-mode operation. The GEMS device can be used as a high-speed digital-optical modulator for a laser-projection display system by collecting the diffracted orders and taking advantage of the low jitter. A color channel is created using a linear array of individually addressable GEMS pixels. A two-dimensional image is produced by sweeping the line image of the array, created by the projection optics, across the display screen. Gray levels in the image are formed using pulse-width modulation (PWM). A high-resolution projection display was developed using three 1080-pixel devices illuminated by red, green, and blue laser-color primaries. The result is an HDTV-format display capable of producing stunning still and motion images with very wide color gamut.
Linearly polarized vector modes: enabling MIMO-free mode-division multiplexing.
Wang, Lixian; Nejad, Reza Mirzaei; Corsi, Alessandro; Lin, Jiachuan; Messaddeq, Younès; Rusch, Leslie; LaRochelle, Sophie
2017-05-15
We experimentally investigate mode-division multiplexing in an elliptical ring core fiber (ERCF) that supports linearly polarized vector modes (LPV). Characterization show that the ERCF exhibits good polarization maintaining properties over eight LPV modes with effective index difference larger than 1 × 10 -4 . The ERCF further displays stable mode power and polarization extinction ratio when subjected to external perturbations. Crosstalk between the LPV modes, after propagating through 0.9 km ERCF, is below -14 dB. By using six LPV modes as independent data channels, we achieved the transmission of 32 Gbaud QPSK over 0.9 km ERCF without any multiple-input-multiple-output (MIMO) or polarization-division multiplexing (PDM) signal processing.
Visual effects in great bowerbird sexual displays and their implications for signal design
Endler, John A.; Gaburro, Julie; Kelley, Laura A.
2014-01-01
It is often assumed that the primary purpose of a male's sexual display is to provide information about quality, or to strongly stimulate prospective mates, but other functions of courtship displays have been relatively neglected. Male great bowerbirds (Ptilonorhynchus nuchalis) construct bowers that exploit the female's predictable field of view (FOV) during courtship displays by creating forced perspective illusions, and the quality of illusion is a good predictor of mating success. Here, we present and discuss two additional components of male courtship displays that use the female's predetermined viewpoint: (i) the rapid and diverse flashing of coloured objects within her FOV and (ii) chromatic adaptation of the female's eyes that alters her perception of the colour of the displayed objects. Neither is directly related to mating success, but both are likely to increase signal efficacy, and may also be associated with attracting and holding the female's attention. Signal efficacy is constrained by trade-offs between the signal components; there are both positive and negative interactions within multicomponent signals. Important signal components may have a threshold effect on fitness rather than the often assumed linear relationship. PMID:24695430
Chao, Jianbin; Wang, Huijuan; Zhang, Yongbin; Yin, Caixia; Huo, Fangjun; Song, Kailun; Li, Zhiqing; Zhang, Ting; Zhao, Yaqin
2017-11-01
A novel pH fluorescent probe 1-(pyren-1-yl)-3-(6-methoxypridin-3-yl)-acrylketone, (PMPA), which had a pyrene structure attached to methoxypyridine, was synthesized for monitoring extremely acidic and alkaline pH. The pH titrations indicated that PMPA displayed a remarkable emission enhancement with a pK a of 2.70 and responded linearly to minor pH fluctuations within the extremely acidic range of 1.26-3.97. Interestingly, PMPA also exhibited strong pH-dependent characteristics with pK a 9.32 and linear response to extreme-alkalinity range of 8.54-10.36. In addition, PMPA displayed a good selectivity, excellent photostability and large Stokes shift (167nm). Furthermore, the probe PMPA had excellent cell membrane permeability and was applied successfully to rapidly detect pH in living cells. pH value in these organs was closely related to many diseases, so these findings suggested that the probe had potential application in pH detecting for disease diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Hongwei; Lang, Qiaolin; Li, Liang; Liang, Bo; Tang, Xiangjiang; Kong, Lingrang; Mascini, Marco; Liu, Aihua
2013-06-18
The display of glucose oxidase (GOx) on yeast cell surface using a-agglutinin as an anchor motif was successfully developed. Both the immunochemical analysis and enzymatic assay showed that active GOx was efficiently expressed and translocated on the cell surface. Compared with conventional GOx, the yeast cell surface that displayed GOx (GOx-yeast) demonstrated excellent enzyme properties, such as good stability within a wide pH range (pH 3.5-11.5), good thermostability (retaining over 94.8% enzyme activity at 52 °C and 84.2% enzyme activity at 56 °C), and high d-glucose specificity. In addition, direct electrochemistry was achieved at a GOx-yeast/multiwalled-carbon-nanotube modified electrode, suggesting that the host cell of yeast did not have any adverse effect on the electrocatalytic property of the recombinant GOx. Thus, a novel electrochemical glucose biosensor based on this GOx-yeast was developed. The as-prepared biosensor was linear with the concentration of d-glucose within the range of 0.1-14 mM and a low detection limit of 0.05 mM (signal-to-noise ratio of S/N = 3). Moreover, the as-prepared biosensor is stable, specific, reproducible, simple, and cost-effective, which can be applicable for real sample detection. The proposed strategy to construct robust GOx-yeast may be applied to explore other oxidase-displaying-system-based whole-cell biocatalysts, which can find broad potential application in biosensors, bioenergy, and industrial catalysis.
Computer user's manual for a generalized curve fit and plotting program
NASA Technical Reports Server (NTRS)
Schlagheck, R. A.; Beadle, B. D., II; Dolerhie, B. D., Jr.; Owen, J. W.
1973-01-01
A FORTRAN coded program has been developed for generating plotted output graphs on 8-1/2 by 11-inch paper. The program is designed to be used by engineers, scientists, and non-programming personnel on any IBM 1130 system that includes a 1627 plotter. The program has been written to provide a fast and efficient method of displaying plotted data without having to generate any additions. Various output options are available to the program user for displaying data in four different types of formatted plots. These options include discrete linear, continuous, and histogram graphical outputs. The manual contains information about the use and operation of this program. A mathematical description of the least squares goodness of fit test is presented. A program listing is also included.
New Vectorial Propulsion System and Trajectory Control Designs for Improved AUV Mission Autonomy.
Masmitja, Ivan; Gonzalez, Julian; Galarza, Cesar; Gomariz, Spartacus; Aguzzi, Jacopo; Del Rio, Joaquin
2018-04-17
Autonomous Underwater Vehicles (AUV) are proving to be a promising platform design for multidisciplinary autonomous operability with a wide range of applications in marine ecology and geoscience. Here, two novel contributions towards increasing the autonomous navigation capability of a new AUV prototype (the Guanay II) as a mix between a propelled vehicle and a glider are presented. Firstly, a vectorial propulsion system has been designed to provide full vehicle maneuverability in both horizontal and vertical planes. Furthermore, two controllers have been designed, based on fuzzy controls, to provide the vehicle with autonomous navigation capabilities. Due to the decoupled system propriety, the controllers in the horizontal plane have been designed separately from the vertical plane. This class of non-linear controllers has been used to interpret linguistic laws into different zones of functionality. This method provided good performance, used as interpolation between different rules or linear controls. Both improvements have been validated through simulations and field tests, displaying good performance results. Finally, the conclusion of this work is that the Guanay II AUV has a solid controller to perform autonomous navigation and carry out vertical immersions.
Dominance in Domestic Dogs: A Quantitative Analysis of Its Behavioural Measures
van der Borg, Joanne A. M.; Schilder, Matthijs B. H.; Vinke, Claudia M.; de Vries, Han
2015-01-01
A dominance hierarchy is an important feature of the social organisation of group living animals. Although formal and/or agonistic dominance has been found in captive wolves and free-ranging dogs, applicability of the dominance concept in domestic dogs is highly debated, and quantitative data are scarce. Therefore, we investigated 7 body postures and 24 behaviours in a group of domestic dogs for their suitability as formal status indicators. The results showed that high posture, displayed in most dyadic relationships, and muzzle bite, displayed exclusively by the highest ranking dogs, qualified best as formal dominance indicators. The best formal submission indicator was body tail wag, covering most relationships, and two low postures, covering two-thirds of the relationships. In addition, both mouth lick, as included in Schenkel’s active submission, and pass under head qualified as formal submission indicators but were shown almost exclusively towards the highest ranking dogs. Furthermore, a status assessment based on changes in posture displays, i.e., lowering of posture (LoP) into half-low, low, low-on-back or on-back, was the best status indicator for most relationships as it showed good coverage (91% of the dyads), a nearly linear hierarchy (h’ = 0.94, p<0.003) and strong unidirectionality (DCI = 0.97). The associated steepness of 0.79 (p<0.0001) indicated a tolerant dominance style for this dog group. No significant correlations of rank with age or weight were found. Strong co-variation between LoP, high posture, and body tail wag justified the use of dominance as an intervening variable. Our results are in line with previous findings for captive wolves and free-ranging dogs, for formal dominance with strong linearity based on submission but not aggression. They indicate that the ethogram for dogs is best redefined by distinguishing body postures from behavioural activities. A good insight into dominance hierarchies and its indicators will be helpful in properly interpreting dog-dog relationships and diagnosing problem behaviour in dogs. PMID:26309101
Dominance in Domestic Dogs: A Quantitative Analysis of Its Behavioural Measures.
van der Borg, Joanne A M; Schilder, Matthijs B H; Vinke, Claudia M; de Vries, Han
2015-01-01
A dominance hierarchy is an important feature of the social organisation of group living animals. Although formal and/or agonistic dominance has been found in captive wolves and free-ranging dogs, applicability of the dominance concept in domestic dogs is highly debated, and quantitative data are scarce. Therefore, we investigated 7 body postures and 24 behaviours in a group of domestic dogs for their suitability as formal status indicators. The results showed that high posture, displayed in most dyadic relationships, and muzzle bite, displayed exclusively by the highest ranking dogs, qualified best as formal dominance indicators. The best formal submission indicator was body tail wag, covering most relationships, and two low postures, covering two-thirds of the relationships. In addition, both mouth lick, as included in Schenkel's active submission, and pass under head qualified as formal submission indicators but were shown almost exclusively towards the highest ranking dogs. Furthermore, a status assessment based on changes in posture displays, i.e., lowering of posture (LoP) into half-low, low, low-on-back or on-back, was the best status indicator for most relationships as it showed good coverage (91% of the dyads), a nearly linear hierarchy (h' = 0.94, p<0.003) and strong unidirectionality (DCI = 0.97). The associated steepness of 0.79 (p<0.0001) indicated a tolerant dominance style for this dog group. No significant correlations of rank with age or weight were found. Strong co-variation between LoP, high posture, and body tail wag justified the use of dominance as an intervening variable. Our results are in line with previous findings for captive wolves and free-ranging dogs, for formal dominance with strong linearity based on submission but not aggression. They indicate that the ethogram for dogs is best redefined by distinguishing body postures from behavioural activities. A good insight into dominance hierarchies and its indicators will be helpful in properly interpreting dog-dog relationships and diagnosing problem behaviour in dogs.
DOT National Transportation Integrated Search
2009-04-28
A study was conducted to explore the utility and recognition of lines and linear patterns on electronic displays depicting aeronautical charting information, such as electronic charts and moving map displays. The goal of this research is to support t...
Burns, Ryan D; Hannon, James C; Brusseau, Timothy A; Eisenman, Patricia A; Shultz, Barry B; Saint-Maurice, Pedro F; Welk, Gregory J; Mahar, Matthew T
2016-01-01
A popular algorithm to predict VO2Peak from the one-mile run/walk test (1MRW) includes body mass index (BMI), which manifests practical issues in school settings. The purpose of this study was to develop an aerobic capacity model from 1MRW in adolescents independent of BMI. Cardiorespiratory endurance data were collected on 90 adolescents aged 13-16 years. The 1MRW was administered on an outside track and a laboratory VO2Peak test was conducted using a maximal treadmill protocol. Multiple linear regression was employed to develop the prediction model. Results yielded the following algorithm: VO2Peak = 7.34 × (1MRW speed in m s(-1)) + 0.23 × (age × sex) + 17.75. The New Model displayed a multiple correlation and prediction error of R = 0.81, standard error of the estimate = 4.78 ml kg(-1) · min(-1), with measured VO2Peak and good criterion-referenced (CR) agreement into FITNESSGRAM's Healthy Fitness Zone (Kappa = 0.62; percentage agreement = 84.4%; Φ = 0.62). The New Model was validated using k-fold cross-validation and showed homoscedastic residuals across the range of predicted scores. The omission of BMI did not compromise accuracy of the model. In conclusion, the New Model displayed good predictive accuracy and good CR agreement with measured VO2Peak in adolescents aged 13-16 years.
Ahmed, Farid; Perveen, Samina; Shah, Kiramat; Shah, Muhammad Raza; Ahmed, Shakil
2018-01-01
In this study a new calix[4]arene triazole 5 was successfully synthesized using click reaction and characterized through UV-visible, FT-IR, 1 H NMR spectroscopes and Mass Spectrometry. The supramolecular interaction of compound 5 towards commonly used drugs has been carried out using UV-Visible spectroscopy. The supramolecule 5 showed characteristic enhancement in the absorbance intensity after mixing with Cefuroxime at pH (2-12). Compound 5 displayed considerably good interactions with cefuroxime in the presence of other drugs. Compound 5 exhibits linear relationship with cefuroxime concentration in the range of (10-80µM) with regression value of 0.9954. The standard deviation for 50µM Cefuroxime was found to be 0.01 and the limit of detection for cefuroxime was calculated to be 2µM. Job's plot experiments showed 1:1 (5: cefuroxime) binding stoichiometry between compound 5 and cefuroxime. Supramolecule 5 displayed fairly good spectrophotometric recognition of Cefuroxime in human blood plasma and tap water thus showing that the ingredients of tap water and plasma sample was inert in the recognition of cefuroxime. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott
2017-09-01
We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.
Runaway sexual selection leads to good genes.
Chandler, Christopher H; Ofria, Charles; Dworkin, Ian
2013-01-01
Mate choice and sexual displays are widespread in nature, but their evolutionary benefits remain controversial. Theory predicts these traits can be favored by runaway sexual selection, in which preference and display reinforce one another due to genetic correlation; or by good genes benefits, in which mate choice is advantageous because extreme displays indicate a well-adapted genotype. However, these hypotheses are not mutually exclusive, and the adaptive benefits underlying mate choice can themselves evolve. In particular, examining how and why sexual displays become indicators of good genes is challenging in natural systems. Here, we use experimental evolution in "digital organisms" to demonstrate the origins of condition-dependent indicator displays following their spread due to a runaway process. Surprisingly, handicap-like costs are not necessary for displays to become indicators of male viability. Instead, a pleiotropic genetic architecture underlies both displays and viability. Runaway sexual selection and good genes benefits should thus be viewed as interacting mechanisms that reinforce one another. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.
Dynamics and circuit of a chaotic system with a curve of equilibrium points
NASA Astrophysics Data System (ADS)
Pham, Viet-Thanh; Volos, Christos; Kapitaniak, Tomasz; Jafari, Sajad; Wang, Xiong
2018-03-01
Although chaotic systems have been intensively studied since the 1960s, new systems with mysterious features are still of interest. A novel chaotic system including hyperbolic functions is proposed in this work. Especially, the system has an infinite number of equilibrium points. Dynamics of the system are investigated by using non-linear tools such as phase portrait, bifurcation diagram, and Lyapunov exponent. It is interesting that the system can display coexisting chaotic attractors. An electronic circuit for realising the chaotic system has been implemented. Experimental results show a good agreement with theoretical ones.
Proteus-MOC: A 3D deterministic solver incorporating 2D method of characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marin-Lafleche, A.; Smith, M. A.; Lee, C.
2013-07-01
A new transport solution methodology was developed by combining the two-dimensional method of characteristics with the discontinuous Galerkin method for the treatment of the axial variable. The method, which can be applied to arbitrary extruded geometries, was implemented in PROTEUS-MOC and includes parallelization in group, angle, plane, and space using a top level GMRES linear algebra solver. Verification tests were performed to show accuracy and stability of the method with the increased number of angular directions and mesh elements. Good scalability with parallelism in angle and axial planes is displayed. (authors)
Kim, Dae-Hee; Choi, Jae-Hun; Lim, Myung-Eun; Park, Soo-Jun
2008-01-01
This paper suggests the method of correcting distance between an ambient intelligence display and a user based on linear regression and smoothing method, by which distance information of a user who approaches to the display can he accurately output even in an unanticipated condition using a passive infrared VIR) sensor and an ultrasonic device. The developed system consists of an ambient intelligence display and an ultrasonic transmitter, and a sensor gateway. Each module communicates with each other through RF (Radio frequency) communication. The ambient intelligence display includes an ultrasonic receiver and a PIR sensor for motion detection. In particular, this system selects and processes algorithms such as smoothing or linear regression for current input data processing dynamically through judgment process that is determined using the previous reliable data stored in a queue. In addition, we implemented GUI software with JAVA for real time location tracking and an ambient intelligence display.
Chen, Song; Hou, Peng; Wang, Jing; Fu, Shuang; Liu, Lei
2018-05-28
We have successfully developed a new green-emitting H 2 S fluorescence probe employing a 2,4-dinitrophenyl ether moiety as the sensing group based on 3'-formyl-4'-hydroxybiphenyl-4-carbonitrile. This probe displayed a rapid (2 min), sensitive (the detection limit was 0.18 μM) and selective with a large Stokes shift (183 nm) in response to H 2 S, which was beneficial for fluorescence sensing and cell imaging studies. Moreover, this probe can qualitatively and quantitatively detect H 2 S with a good linearity (R 2 = 0.9991). Importantly, this probe had been used for the detection of H 2 S in living MDA-MB-231 cells with good performance. Copyright © 2018 Elsevier B.V. All rights reserved.
A Palladium-Tin Modified Microband Electrode Array for Nitrate Determination
Fu, Yexiang; Bian, Chao; Kuang, Jian; Wang, Jinfen; Tong, Jianhua; Xia, Shanhong
2015-01-01
A microband electrode array modified with palladium-tin bimetallic composite has been developed for nitrate determination. The microband electrode array was fabricated by Micro Electro-Mechanical System (MEMS) technique. Palladium and tin were electrodeposited successively on the electrode, forming a double-layer structure. The effect of the Pd-Sn composite was investigated and its enhancement of catalytic activity and lifetime was revealed. The Pd-Sn modified electrode showed good linearity (R2 = 0.998) from 1 mg/L to 20 mg/L for nitrate determination with a sensitivity of 398 μA/(mg∙L−1∙cm2). The electrode exhibited a satisfying analytical performance after 60 days of storage, indicating a long lifetime. Good repeatability was also displayed by the Pd-Sn modified electrodes. The results provided an option for nitrate determination in water. PMID:26389904
Liu, Xiuhui; Bu, Caihong; Nan, Zhihan; Zheng, Lichun; Qiu, Yu; Lu, Xiaoquan
2013-02-15
We report on a new approach for the electrochemical detection of hydrogen peroxide (H2O2) based on Cytochrome C (Cyt c) immobilized ionic liquid (IL)-functionalized multi-walled carbon nanotubes (MWCNTs) modified glass carbon electrode (GCE). Functionalization of multi-walled carbon nanotube with amine-terminated ionic liquid materials was characterized using fourier transform infrared spectroscopy (FTIR), UV-vis spectra, and electrochemical impedance spectroscopy (EIS), and the results showed that the covalent modification of MWCNTs with ILs exhibited a high surface area for enzyme immobilization and provided a good microenvironment for Cyt c to retain its bioelectrocatalytic activity toward H2O2. Amperometry was used to evaluate the catalytic activity of the cyt c towards H2O2. The proposed biosensor exhibited a wide linear response range nearly 4 orders of magnitude of H2O2 (4.0 × 10(-8)M-1.0 × 10(-4)M) with a good linearity (0.9980) and a low detection limit of 1.3 × 10(-8)M (based on S/N=3). Furthermore, the biosensor also displays some other excellent characteristics such as high selectivity, good reproducibility and long-term stability. Thus, the biosensor constructed in this study has great potential for detecting H2O2 in the complex biosystems. Copyright © 2012 Elsevier B.V. All rights reserved.
New Vectorial Propulsion System and Trajectory Control Designs for Improved AUV Mission Autonomy
Gonzalez, Julian; Galarza, Cesar; Aguzzi, Jacopo; del Rio, Joaquin
2018-01-01
Autonomous Underwater Vehicles (AUV) are proving to be a promising platform design for multidisciplinary autonomous operability with a wide range of applications in marine ecology and geoscience. Here, two novel contributions towards increasing the autonomous navigation capability of a new AUV prototype (the Guanay II) as a mix between a propelled vehicle and a glider are presented. Firstly, a vectorial propulsion system has been designed to provide full vehicle maneuverability in both horizontal and vertical planes. Furthermore, two controllers have been designed, based on fuzzy controls, to provide the vehicle with autonomous navigation capabilities. Due to the decoupled system propriety, the controllers in the horizontal plane have been designed separately from the vertical plane. This class of non-linear controllers has been used to interpret linguistic laws into different zones of functionality. This method provided good performance, used as interpolation between different rules or linear controls. Both improvements have been validated through simulations and field tests, displaying good performance results. Finally, the conclusion of this work is that the Guanay II AUV has a solid controller to perform autonomous navigation and carry out vertical immersions. PMID:29673224
ERIC Educational Resources Information Center
Fields, Alan
1980-01-01
Looks at an alternative method to linear notes for organizing thoughts when preparing a talk or paper. This method displays the manner in which the relationships of a subject are organized and offers a format for displaying complex inter-dependencies in place of linear notes. (Author/MER)
DOT National Transportation Integrated Search
2008-09-01
This industry survey documents the symbols for navigation aids, airports, lines, and linear patterns currently in use by avionics manufactureres and chart providers for depicting aeronautical charting information. Nine avionics display manufacturers ...
Jin, Tingting; Cheng, Jing; Cai, Cuicui; Cheng, Min; Wu, Shiju; Zhou, Hongbin
2016-07-29
In this paper, graphene oxide was coated onto a stainless steel wire through sol-gel technique and it was used as a solid phase microextraction (SPME) fiber. The prepared fiber was characterized by scanning electron microscopy (SEM), which displayed that the fiber had crinkled surface and porous structure The application of the fiber was evaluated through the headspace SPME of nine organophosphate ester flame retardants (OPFRs) with different characteristics in water samples followed by gas chromatography and nitrogen-phosphorous detector (GC/NPD). The major factors influencing the extraction efficiency, including the extraction and desorption conditions, were studied and optimized. Under the optimum conditions, the proposed method was evaluated, and applied to the analysis of organophosphate ester flame retardants in real environmental water samples. The results demonstrated the HS-SPME method based on GO sol-gel fiber had good linearity (R>0.9928), and limits of detection (1.4-135.6ngL(-1)), high repeatability (RSD<9.8%) and good recovery (76.4-112.4%). The GO based sol-gel fiber displayed bigger extraction capability than the commercial PDMS fiber and the pure sol-gel fiber for both polar and apolar organophosphate esters, especially for the OPFRs containing benzene rings. Copyright © 2016 Elsevier B.V. All rights reserved.
Head-on collisions of unequal mass black holes in D=5 dimensions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Witek, Helvi; Cardoso, Vitor; Department of Physics and Astronomy, University of Mississippi, University, Mississippi 38677
We study head-on collisions of unequal mass black hole binaries in D=5 spacetime dimensions, with mass ratios between 1:1 and 1:4. Information about gravitational radiation is extracted by using the Kodama-Ishibashi gauge-invariant formalism and details of the apparent horizon of the final black hole. We present waveforms, total integrated energy and momentum for this process. Our results show surprisingly good agreement, within 5% or less, with those extrapolated from linearized, point-particle calculations. Our results also show that consistency with the area theorem bound requires that the same process in a large number of spacetime dimensions must display new features.
DOT National Transportation Integrated Search
2009-01-01
This report describes a study conducted to explore the utility and recognition of lines and linear patterns on electronic displays depicting aeronautical charting information. The study gathered data from a large number of pilots who conduct all type...
Research on pressure tactile sensing technology based on fiber Bragg grating array
NASA Astrophysics Data System (ADS)
Song, Jinxue; Jiang, Qi; Huang, Yuanyang; Li, Yibin; Jia, Yuxi; Rong, Xuewen; Song, Rui; Liu, Hongbin
2015-09-01
A pressure tactile sensor based on the fiber Bragg grating (FBG) array is introduced in this paper, and the numerical simulation of its elastic body was implemented by finite element software (ANSYS). On the basis of simulation, fiber Bragg grating strings were implanted in flexible silicone to realize the sensor fabrication process, and a testing system was built. A series of calibration tests were done via the high precision universal press machine. The tactile sensor array perceived external pressure, which is demodulated by the fiber grating demodulation instrument, and three-dimension pictures were programmed to display visually the position and size. At the same time, a dynamic contact experiment of the sensor was conducted for simulating robot encountering other objects in the unknown environment. The experimental results show that the sensor has good linearity, repeatability, and has the good effect of dynamic response, and its pressure sensitivity was 0.03 nm/N. In addition, the sensor also has advantages of anti-electromagnetic interference, good flexibility, simple structure, low cost and so on, which is expected to be used in the wearable artificial skin in the future.
NASA Astrophysics Data System (ADS)
Ha, Nguyen Hai; Thinh, Dao Duc; Huong, Nguyen Thanh; Phuong, Nguyen Huy; Thach, Phan Duy; Hong, Hoang Si
2018-03-01
Zinc oxide (ZnO) nanoparticles loaded onto 3D reduced graphene oxide (3D-RGO) for carbon monoxide (CO) sensing were synthesized using hydrothermal method. The highly porous ZnO/3D-RGO configuration was stable without collapsing and was deposited on the micro-heater of the CO gas sensor. The resulting CO gas sensor displayed high sensitivity, fast response/recovery, and good linearity. The sensor achieved a response value of 85.2% for 1000 ppm CO at a working temperature of 200 °C. The response and recovery times of the sensor were 7 and 9 s for 1000 ppm CO at 200 °C. Similarly, the response value, response time, and recovery time of the sensor at room temperature were 27.5%, 14 s, and 15 s, respectively. The sensor demonstrated a distinct response to various CO concentrations in the range of 1-1000 ppm and good selectivity toward CO gas. In addition, the sensor exhibited good repeatability in multi-cycle and long-term stability.
Helicobacter pylori displays spiral trajectories while swimming like a cork-screw in solutions
NASA Astrophysics Data System (ADS)
Constantino, Maira A.; Hardcastle, Joseph M.; Bansil, Rama; Jabbarzadeh, Mehdi; Fu, Henry C.
Helicobacter pylori is a helical shaped bacterium that causes gastritis, ulcers and gastric cancer in humans and other animals. In order to colonize the harsh acidic environment of the stomach H. pylori has evolved a unique biochemical mechanism to go across the viscoelastic gel-like gastric mucus layer. Many studies have been conducted on the swimming of H. pylori in viscous media. However a yet unanswered question is if the helical cell shape influences bacterial swimming dynamics or confers any advantage when swimming in viscous solution. We will present measurements of H. pylori trajectories displaying corkscrew motion while swimming in solution obtained by tracking single cells using 2-dimensional phase contrast imaging at high magnification and fast frame rates and simultaneously imaging their shape. We observe a linear relationship between swimming speed and rotation rate. The experimental trajectories show good agreement with trajectories calculated using a regularized Stokeslet method to model the low Reynolds number swimming behavior. Supported by NSF PHY 1410798 (PI: RB).
Wang, Yaoguang; Zhang, Yong; Wu, Dan; Ma, Hongmin; Pang, Xuehui; Fan, Dawei; Wei, Qin; Du, Bin
2017-01-01
In this work, a novel label-free electrochemical immunosensor was developed for the quantitative detection of alpha fetoprotein (AFP). Multifunctionalized graphene nanocomposites (TB-Au-Fe3O4-rGO) were applied to modify the electrode to achieve the amplification of electrochemical signal. TB-Au-Fe3O4-rGO includes the advantages of graphene, ferroferric oxide nanoparticles (Fe3O4 NPs), gold nanoparticles (Au NPs) and toluidine blue (TB). As a kind of redox probe, TB can produce the electrochemical signal. Graphene owns large specific surface area, high electrical conductivity and good adsorption property to load a large number of TB. Fe3O4 NPs have good electrocatalytic performance towards the redox of TB. Au NPs have good biocompatibility to capture the antibodies. Due to the good electrochemical performance of TB-Au-Fe3O4-rGO, the effective and sensitive detection of AFP was achieved by the designed electrochemical immunosensor. Under optimal conditions, the designed immunosensor exhibited a wide linear range from 1.0 × 10−5 ng/mL to 10.0 ng/mL with a low detection limit of 2.7 fg/mL for AFP. It also displayed good electrochemical performance including good reproducibility, selectivity and stability, which would provide potential applications in the clinical diagnosis of other tumor markers. PMID:28186128
NASA Astrophysics Data System (ADS)
Shariati, M.; Talon, L.; Martin, J.; Rakotomalala, N.; Salin, D.; Yortsos, Y. C.
2004-11-01
We consider miscible displacement between parallel plates in the absence of diffusion, with a concentration-dependent viscosity. By selecting a piecewise viscosity function, this can also be considered as ‘three-fluid’ flow in the same geometry. Assuming symmetry across the gap and based on the lubrication (‘equilibrium’) approximation, a description in terms of two quasi-linear hyperbolic equations is obtained. We find that the system is hyperbolic and can be solved analytically, when the mobility profile is monotonic, or when the mobility of the middle phase is smaller than its neighbours. When the mobility of the middle phase is larger, a change of type is displayed, an elliptic region developing in the composition space. Numerical solutions of Riemann problems of the hyperbolic system spanning the elliptic region, with small diffusion added, show good agreement with the analytical outside, but an unstable behaviour inside the elliptic region. In these problems, the elliptic region arises precisely at the displacement front. Crossing the elliptic region requires the solution of essentially an eigenvalue problem of the full higher-dimensional model, obtained here using lattice BGK simulations. The hyperbolic-to-elliptic change-of-type reflects the failing of the lubrication approximation, underlying the quasi-linear hyperbolic formalism, to describe the problem uniformly. The obtained solution is analogous to non-classical shocks recently suggested in problems with change of type.
Re-Mediating Classroom Activity with a Non-Linear, Multi-Display Presentation Tool
ERIC Educational Resources Information Center
Bligh, Brett; Coyle, Do
2013-01-01
This paper uses an Activity Theory framework to evaluate the use of a novel, multi-screen, non-linear presentation tool. The Thunder tool allows presenters to manipulate and annotate multiple digital slides and to concurrently display a selection of juxtaposed resources across a wall-sized projection area. Conventional, single screen presentation…
An Inventory Model for Special Display Goods with Seasonal Demand
NASA Astrophysics Data System (ADS)
Kawakatsu, Hidefumi
2010-10-01
The present study discusses the retailer's optimal replenishment policy for seasonal products. The demand rate of seasonal merchandise such as clothes, sporting goods, children's toys and electrical home appearances tends to decrease with time after reaching its maximum value. In this study, we focus on "Special Display Goods", which are heaped up in end displays or special areas at retail stores. They are sold at a fast velocity when their quantity displayed is large, but are sold at a low velocity if the quantity becomes small. We develop the model with a finite time horizon (selling period) to determine the optimal replenishment policy, which maximizes the retailer's total profit. Numerical examples are presented to illustrate the theoretical underpinnings of the proposed model.
Second-order processing of four-stroke apparent motion.
Mather, G; Murdoch, L
1999-05-01
In four-stroke apparent motion displays, pattern elements oscillate between two adjacent positions and synchronously reverse in contrast, but appear to move unidirectionally. For example, if rightward shifts preserve contrast but leftward shifts reverse contrast, consistent rightward motion is seen. In conventional first-order displays, elements reverse in luminance contrast (e.g. light elements become dark, and vice-versa). The resulting perception can be explained by responses in elementary motion detectors turned to spatio-temporal orientation. Second-order motion displays contain texture-defined elements, and there is some evidence that they excite second-order motion detectors that extract spatio-temporal orientation following the application of a non-linear 'texture-grabbing' transform by the visual system. We generated a variety of second-order four-stroke displays, containing texture-contrast reversals instead of luminance contrast reversals, and used their effectiveness as a diagnostic test for the presence of various forms of non-linear transform in the second-order motion system. Displays containing only forward or only reversed phi motion sequences were also tested. Displays defined by variation in luminance, contrast, orientation, and size were effective. Displays defined by variation in motion, dynamism, and stereo were partially or wholly ineffective. Results obtained with contrast-reversing and four-stroke displays indicate that only relatively simple non-linear transforms (involving spatial filtering and rectification) are available during second-order energy-based motion analysis.
Effects of X-shaped reduction-sensitive amphiphilic block copolymer on drug delivery.
Xiao, Haijun; Wang, Lu
2015-01-01
To study the effects of X-shaped amphiphilic block copolymers on delivery of docetaxel (DTX) and the reduction-sensitive property on drug release, a novel reduction-sensitive amphiphilic copolymer, (PLGA)2-SS-4-arm-PEG2000 with a Gemini-like X-shape, was successfully synthesized. The formation of nanomicelles was proved with respect to the blue shift of the emission fluorescence as well as the fluorescent intensity increase of coumarin 6-loaded particles. The X-shaped polymers exhibited a smaller critical micelle concentration value and possessed higher micellar stability in comparison with those of linear ones. The size of X-shaped (PLGA)2-SS-4-arm-PEG2000 polymer nanomicelles (XNMs) was much smaller than that of nanomicelles prepared with linear polymers. The reduction sensitivity of polymers was confirmed by the increase of micellar sizes as well as the in vitro drug release profile of DTX-loaded XNMs (DTX/XNMs). Cytotoxicity assays in vitro revealed that the blank XNMs were nontoxic against A2780 cells up to a concentration of 50 µg/mL, displaying good biocompatibility. DTX/XNMs were more toxic against A2780 cells than other formulations in both dose- and time-dependent manners. Cellular uptake assay displayed a higher intracellular drug delivery efficiency of XNMs than that of nanomicelles prepared with linear polymers. Besides, the promotion of tubulin polymerization induced by DTX was visualized by immunofluorescence analysis, and the acceleration of apoptotic process against A2780 cells was also imaged using a fluorescent staining method. Therefore, this X-shaped reduction-sensitive (PLGA)2-SS-4-arm-PEG2000 copolymer could effectively improve the micellar stability and significantly enhance the therapeutic efficacy of DTX by increasing the cellular uptake and selectively accelerating the drug release inside cancer cells.
NASA Astrophysics Data System (ADS)
Kengne, J.; Jafari, S.; Njitacke, Z. T.; Yousefi Azar Khanian, M.; Cheukem, A.
2017-11-01
Mathematical models (ODEs) describing the dynamics of almost all continuous time chaotic nonlinear systems (e.g. Lorenz, Rossler, Chua, or Chen system) involve at least a nonlinear term in addition to linear terms. In this contribution, a novel (and singular) 3D autonomous chaotic system without linear terms is introduced. This system has an especial feature of having two twin strange attractors: one ordinary and one symmetric strange attractor when the time is reversed. The complex behavior of the model is investigated in terms of equilibria and stability, bifurcation diagrams, Lyapunov exponent plots, time series and Poincaré sections. Some interesting phenomena are found including for instance, period-doubling bifurcation, antimonotonicity (i.e. the concurrent creation and annihilation of periodic orbits) and chaos while monitoring the system parameters. Compared to the (unique) case previously reported by Xu and Wang (2014) [31], the system considered in this work displays a more 'elegant' mathematical expression and experiences richer dynamical behaviors. A suitable electronic circuit (i.e. the analog simulator) is designed and used for the investigations. Pspice based simulation results show a very good agreement with the theoretical analysis.
NASA Technical Reports Server (NTRS)
Dey, D.
1972-01-01
The effect of a prediction display on the human transfer characteristics is explained with the aid of a quasi-linear model. The prediction display causes an increase of the gain factor and the lead factor, a diminishing of the lag factor and a decrease of the remnant. Altogether, these factors yield a smaller mean square value of the control deviation and a simultaneous decrease of the mean square value of the stick signal.
What is 3D good for? A review of human performance on stereoscopic 3D displays
NASA Astrophysics Data System (ADS)
McIntire, John P.; Havig, Paul R.; Geiselman, Eric E.
2012-06-01
This work reviews the human factors-related literature on the task performance implications of stereoscopic 3D displays, in order to point out the specific performance benefits (or lack thereof) one might reasonably expect to observe when utilizing these displays. What exactly is 3D good for? Relative to traditional 2D displays, stereoscopic displays have been shown to enhance performance on a variety of depth-related tasks. These tasks include judging absolute and relative distances, finding and identifying objects (by breaking camouflage and eliciting perceptual "pop-out"), performing spatial manipulations of objects (object positioning, orienting, and tracking), and navigating. More cognitively, stereoscopic displays can improve the spatial understanding of 3D scenes or objects, improve memory/recall of scenes or objects, and improve learning of spatial relationships and environments. However, for tasks that are relatively simple, that do not strictly require depth information for good performance, where other strong cues to depth can be utilized, or for depth tasks that lie outside the effective viewing volume of the display, the purported performance benefits of 3D may be small or altogether absent. Stereoscopic 3D displays come with a host of unique human factors problems including the simulator-sickness-type symptoms of eyestrain, headache, fatigue, disorientation, nausea, and malaise, which appear to effect large numbers of viewers (perhaps as many as 25% to 50% of the general population). Thus, 3D technology should be wielded delicately and applied carefully; and perhaps used only as is necessary to ensure good performance.
Singh, Gagandeep; Sharma, Anuradha; Kaur, Harpreet; Ishar, Mohan Paul S
2016-02-01
Regio- and stereoselective 1,3-dipolar cycloadditions of C-(chrom-4-one-3-yl)-N-phenylnitrones (N) with different mono-substituted, disubstituted, and cyclic dipolarophiles were carried out to obtain substituted N-phenyl-3'-(chrom-4-one-3-yl)-isoxazolidines (1-40). All the synthesized compounds were assayed for their in vitro antibacterial activity and display significant inhibitory potential; in particular, compound 32 exhibited good inhibitory activity against Salmonella typhymurium-1 & Salmonella typhymurium-2 with minimum inhibitory concentration value of 1.56 μg/mL and also showed good potential against methicillin-resistant Staphylococcus aureus with minimum inhibitory concentration 3.12 μg/mL. Quantitative structure activity relationship investigations with stepwise multiple linear regression analysis and docking simulation studies have been performed for validation of the observed antibacterial potential of the investigated compounds for determination of the most important parameters regulating antibacterial activities. © 2015 John Wiley & Sons A/S.
DPSSL for direct dicing and drilling of dielectrics
NASA Astrophysics Data System (ADS)
Ashkenasi, David; Schwagmeier, M.
2007-02-01
New strategies in laser micro processing of glasses and other optically transparent materials are being developed with increasing interest and intensity using diode pumped solid state laser (DPSSL) systems generating short or ultra-short pulses in the optical spectra at good beam quality. Utilizing non-linear absorption channels, it can be demonstrated that ns green (532 nm) laser light can scribe, dice, full body cut and drill (flat) borofloat and borosilicate glasses at good quality. Outside of the correct choice in laser parameters, an intelligent laser beam management plays an important role in successful micro processing of glass. This application characterizes a very interesting alternative where standard methods demonstrate severe limitations such as diamond dicing, CO2 laser treatment or water jet cutting, especially for certain type of optical materials and/or geometric conditions. Application near processing examples using different DPSSL systems generating ns pulsed light at 532 nm in TEM 00 at average powers up to 10 W are presented and discussed in respect to potential applications in display technology, micro electronics and optics.
Contrast Transmission In Medical Image Display
NASA Astrophysics Data System (ADS)
Pizer, Stephen M.; Zimmerman, John B.; Johnston, R. Eugene
1982-11-01
The display of medical images involves transforming recorded intensities such at CT numbers into perceivable intensities such as combinations of color and luminance. For the viewer to extract the most information about patterns of decreasing and increasing recorded intensity, the display designer must pay attention to three issues: 1) choice of display scale, including its discretization; 2) correction for variations in contrast sensitivity across the display scale due to the observer and the display device (producing an honest display); and 3) contrast enhancement based on the information in the recorded image and its importance, determined by viewing objectives. This paper will present concepts and approaches in all three of these areas. In choosing display scales three properties are important: sensitivity, associability, and naturalness of order. The unit of just noticeable difference (jnd) will be carefully defined. An observer experiment to measure the jnd values across a display scale will be specified. The overall sensitivity provided by a scale as measured in jnd's gives a measure of sensitivity called the perceived dynamic range (PDR). Methods for determining the PDR fran the aforementioned PDR values, and PDR's for various grey and pseudocolor scales will be presented. Methods of achieving sensitivity while retaining associability and naturalness of order with pseudocolor scales will be suggested. For any display device and scale it is useful to compensate for the device and observer by preceding the device with an intensity mapping (lookup table) chosen so that perceived intensity is linear with display-driving intensity. This mapping can be determined from the aforementioned jnd values. With a linearized display it is possible to standardize display devices so that the same image displayed on different devices or scales (e.g. video and hard copy) will be in sane sense perceptually equivalent. Furthermore, with a linearized display, it is possible to design contrast enhancement mappings that optimize the transmission of information from the recorded image to the display-driving signal with the assurance that this information will not then be lost by a -further nonlinear relation between display-driving and perceived intensity. It is suggested that optimal contrast enhancement mappings are adaptive to the local distribution of recorded intensities.
Liu, Aihua; Lang, Qiaolin; Liang, Bo; Shi, Jianguo
2017-01-15
Glucoamylase-displayed bacteria (GA-bacteria) and glucose dehydrogenase-displayed bacteria (GDH-bacteria) were co-immobilized on multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (GCE) to construct GA-bacteria/GDH-bacteria/MWNTs/GCE biosensor. The biosensor was developed by optimizing the loading amount and the ratio of GA-bacteria to GDH-bacteria. The as-prepared biosensor exhibited a wide dynamic range of 0.2-10mM and a low detection limit of 0.1mM maltose (S/N=3). The biosensor also had a linear response to glucose in the range of 0.1-2.0mM and a low detection limit of 0.04mM glucose (S/N=3). Interestingly, at the same concentration, glucose was 3.75-fold sensitive than that of maltose at the proposed biosensor. No interferences were observed for other possible mono- and disaccharides. The biosensor also demonstrated good long-term storage stability and repeatability. Further, using both GDH-bacteria/MWNTs/GCE biosensor and GA-bacteria/GDH-bacteria/MWNTs/GCE biosensor, glucose and maltose in real samples can be detected. Therefore, the proposed biosensor is capable of monitoring the food manufacturing and fermentation process. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhao, Henan; Bryant, Garnett W.; Griffin, Wesley; Terrill, Judith E.; Chen, Jian
2017-01-01
We designed and evaluated SplitVectors, a new vector field display approach to help scientists perform new discrimination tasks on large-magnitude-range scientific data shown in three-dimensional (3D) visualization environments. SplitVectors uses scientific notation to display vector magnitude, thus improving legibility. We present an empirical study comparing the SplitVectors approach with three other approaches - direct linear representation, logarithmic, and text display commonly used in scientific visualizations. Twenty participants performed three domain analysis tasks: reading numerical values (a discrimination task), finding the ratio between values (a discrimination task), and finding the larger of two vectors (a pattern detection task). Participants used both mono and stereo conditions. Our results suggest the following: (1) SplitVectors improve accuracy by about 10 times compared to linear mapping and by four times to logarithmic in discrimination tasks; (2) SplitVectors have no significant differences from the textual display approach, but reduce cluttering in the scene; (3) SplitVectors and textual display are less sensitive to data scale than linear and logarithmic approaches; (4) using logarithmic can be problematic as participants' confidence was as high as directly reading from the textual display, but their accuracy was poor; and (5) Stereoscopy improved performance, especially in more challenging discrimination tasks. PMID:28113469
Henan Zhao; Bryant, Garnett W; Griffin, Wesley; Terrill, Judith E; Jian Chen
2017-06-01
We designed and evaluated SplitVectors, a new vector field display approach to help scientists perform new discrimination tasks on large-magnitude-range scientific data shown in three-dimensional (3D) visualization environments. SplitVectors uses scientific notation to display vector magnitude, thus improving legibility. We present an empirical study comparing the SplitVectors approach with three other approaches - direct linear representation, logarithmic, and text display commonly used in scientific visualizations. Twenty participants performed three domain analysis tasks: reading numerical values (a discrimination task), finding the ratio between values (a discrimination task), and finding the larger of two vectors (a pattern detection task). Participants used both mono and stereo conditions. Our results suggest the following: (1) SplitVectors improve accuracy by about 10 times compared to linear mapping and by four times to logarithmic in discrimination tasks; (2) SplitVectors have no significant differences from the textual display approach, but reduce cluttering in the scene; (3) SplitVectors and textual display are less sensitive to data scale than linear and logarithmic approaches; (4) using logarithmic can be problematic as participants' confidence was as high as directly reading from the textual display, but their accuracy was poor; and (5) Stereoscopy improved performance, especially in more challenging discrimination tasks.
Liu, Zhiguang; Guo, Yujing; Dong, Chuan
2015-05-01
In this report, a new nanocomposite was successfully synthesized by chemical deposition of nickel nanoparticles (NiNPs) on polyvinylpyrrolidone (PVP) stabilized graphene nanosheets (GNs) with chitosan (CS) as the protective coating. The as obtained nanocomposite (PVP-GNs-NiNPs-CS) was characterized by X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). Benefiting from the synergistic effect of GNs (large surface area and high conductivity), NiNPs (high electrocatalytic activity towards the glucose oxidation) and CS (good film-forming and antifouling ability), a nonenzymatic electrochemical glucose sensor was established. The nanocomposite displays greatly enhanced electrocatalytic activity towards the glucose oxidation in NaOH solution. The PVP-GNs-NiNPs-CS based electrochemical glucose sensor demonstrates good sensitivity, wide linear range (0.1 μM-0.5 mM), outstanding detection limit (30 nM), attractive selectivity, good reproducibility, high stability as well as prominent feasibility for the real sample analysis. The proposed experiment might open up a new possibility for widespread use of non-enzymatic sensors for monitoring blood glucose owing to its advantages of low cost, simple preparation and excellent properties for glucose detection. Copyright © 2015 Elsevier B.V. All rights reserved.
Measurement of urinary calcium using AT89C51RD2 microcontroller.
Neelamegam, P; Jamaludeen, A; Rajendran, A; Raghunathan, R
2009-04-01
A simple and inexpensive absorption technique for determination of calcium ion in urine samples is developed, comprising a light emitting diode (650 nm) as the light source and photodiode as the detector with AT89C51RD2 microcontroller. The design of the system and details of interface, calibration, and procedure of operation are explained in this paper. Software is developed to monitor sample processing and to display the results in liquid crystal display screen. With 15 microl sample volume, a linear output is obtained in the range of 2.5-7.5 mM calcium with a detection limit of 0.06 mM. Interferences from other cations such as monovalent ion and divalent ion are investigated in the expected range, which are normally present in clinical samples, and absorption changes over the pH range of 3-12 are also determined. This system has been demonstrated successfully for the successive assay of calcium in urine samples, with the results comparing well to those achieved and in good agreement with values obtained with the current clinical spectrophotometric method at 95% of confidence level.
Gageostatins A-C, antimicrobial linear lipopeptides from a marine Bacillus subtilis.
Tareq, Fakir Shahidullah; Lee, Min Ah; Lee, Hyi-Seung; Lee, Jong-Seok; Lee, Yeon-Ju; Shin, Hee Jae
2014-01-31
Concerning the requirements of effective drug candidates to combat against high rising multidrug resistant pathogens, we isolated three new linear lipopeptides, gageostatins A-C (1-3), consisting of hepta-peptides and new 3-β-hydroxy fatty acids from the fermentation broth of a marine-derived bacterium Bacillus subtilis. Their structures were elucidated by analyzing a combination of extensive 1D, 2D NMR spectroscopic data and high resolution ESIMS data. Fatty acids, namely 3-β-hydroxy-11-methyltridecanoic and 3-β-hydroxy-9,11-dimethyltridecanoic acids were characterized in lipopeptides 1 and 2, respectively, whereas an unsaturated fatty acid (E)-7,9-dimethylundec-2-enoic acid was assigned in 3. The 3R configuration of the stereocenter of 3-β-hydroxy fatty acids in 1 and 2 was established by Mosher's MTPA method. The absolute stereochemistry of amino acid residues in 1-3 was ascertained by acid hydrolysis followed by Marfey's derivatization studies. Gageostatins 1-3 exhibited good antifungal activities with MICs values of 4-32 µg/mL when tested against pathogenic fungi (R. solani, B. cinerea and C. acutatum) and moderate antibacterial activity against bacteria (B. subtilis, S. aeureus, S. typhi and P. aeruginosa) with MICs values of 8-64 µg/mL. Futhermore, gageostatins 1-3 displayed cytotoxicity against six human cancer cell lines with GI₅₀ values of 4.6-19.6 µg/mL. It is also noteworthy that mixed compounds 1+2 displayed better antifungal and cytotoxic activities than individuals.
Tri-linear interpolation-based cerebral white matter fiber imaging
Jiang, Shan; Zhang, Pengfei; Han, Tong; Liu, Weihua; Liu, Meixia
2013-01-01
Diffusion tensor imaging is a unique method to visualize white matter fibers three-dimensionally, non-invasively and in vivo, and therefore it is an important tool for observing and researching neural regeneration. Different diffusion tensor imaging-based fiber tracking methods have been already investigated, but making the computing faster, fiber tracking longer and smoother and the details shown clearer are needed to be improved for clinical applications. This study proposed a new fiber tracking strategy based on tri-linear interpolation. We selected a patient with acute infarction of the right basal ganglia and designed experiments based on either the tri-linear interpolation algorithm or tensorline algorithm. Fiber tracking in the same regions of interest (genu of the corpus callosum) was performed separately. The validity of the tri-linear interpolation algorithm was verified by quantitative analysis, and its feasibility in clinical diagnosis was confirmed by the contrast between tracking results and the disease condition of the patient as well as the actual brain anatomy. Statistical results showed that the maximum length and average length of the white matter fibers tracked by the tri-linear interpolation algorithm were significantly longer. The tracking images of the fibers indicated that this method can obtain smoother tracked fibers, more obvious orientation and clearer details. Tracking fiber abnormalities are in good agreement with the actual condition of patients, and tracking displayed fibers that passed though the corpus callosum, which was consistent with the anatomical structures of the brain. Therefore, the tri-linear interpolation algorithm can achieve a clear, anatomically correct and reliable tracking result. PMID:25206524
Unsymmetrical squaraines for nonlinear optical materials
NASA Technical Reports Server (NTRS)
Marder, Seth R. (Inventor); Chen, Chin-Ti (Inventor); Cheng, Lap-Tak (Inventor)
1996-01-01
Compositions for use in non-linear optical devices. The compositions have first molecular electronic hyperpolarizability (.beta.) either positive or negative in sign and therefore display second order non-linear optical properties when incorporated into non-linear optical devices.
Cheng, Ta-Chun; Tung, Yi-Ching; Chu, Pei-Yu; Chuang, Chih-Hung; Hsieh, Yuan-Chin; Huang, Chien-Chiao; Wang, Yeng-Tseng; Kao, Chien-Han; Roffler, Steve R.; Cheng, Tian-Lu
2016-01-01
Molecular weight markers that can tolerate denaturing conditions and be auto-detected by secondary antibodies offer great efficacy and convenience for Western Blotting. Here, we describe M&R LE protein markers which contain linear epitopes derived from the heavy chain constant regions of mouse and rabbit immunoglobulin G (IgG Fc LE). These markers can be directly recognized and stained by a wide range of anti-mouse and anti-rabbit secondary antibodies. We selected three mouse (M1, M2 and M3) linear IgG1 and three rabbit (R1, R2 and R3) linear IgG heavy chain epitope candidates based on their respective crystal structures. Western blot analysis indicated that M2 and R2 linear epitopes are effectively recognized by anti-mouse and anti-rabbit secondary antibodies, respectively. We fused the M2 and R2 epitopes (M&R LE) and incorporated the polypeptide in a range of 15–120 kDa auto-detecting markers (M&R LE protein marker). The M&R LE protein marker can be auto-detected by anti-mouse and anti-rabbit IgG secondary antibodies in standard immunoblots. Linear regression analysis of the M&R LE protein marker plotted as gel mobility versus the log of the marker molecular weights revealed good linearity with a correlation coefficient R2 value of 0.9965, indicating that the M&R LE protein marker displays high accuracy for determining protein molecular weights. This accurate, regular and auto-detected M&R LE protein marker may provide a simple, efficient and economical tool for protein analysis. PMID:27494183
Lin, Wen-Wei; Chen, I-Ju; Cheng, Ta-Chun; Tung, Yi-Ching; Chu, Pei-Yu; Chuang, Chih-Hung; Hsieh, Yuan-Chin; Huang, Chien-Chiao; Wang, Yeng-Tseng; Kao, Chien-Han; Roffler, Steve R; Cheng, Tian-Lu
2016-01-01
Molecular weight markers that can tolerate denaturing conditions and be auto-detected by secondary antibodies offer great efficacy and convenience for Western Blotting. Here, we describe M&R LE protein markers which contain linear epitopes derived from the heavy chain constant regions of mouse and rabbit immunoglobulin G (IgG Fc LE). These markers can be directly recognized and stained by a wide range of anti-mouse and anti-rabbit secondary antibodies. We selected three mouse (M1, M2 and M3) linear IgG1 and three rabbit (R1, R2 and R3) linear IgG heavy chain epitope candidates based on their respective crystal structures. Western blot analysis indicated that M2 and R2 linear epitopes are effectively recognized by anti-mouse and anti-rabbit secondary antibodies, respectively. We fused the M2 and R2 epitopes (M&R LE) and incorporated the polypeptide in a range of 15-120 kDa auto-detecting markers (M&R LE protein marker). The M&R LE protein marker can be auto-detected by anti-mouse and anti-rabbit IgG secondary antibodies in standard immunoblots. Linear regression analysis of the M&R LE protein marker plotted as gel mobility versus the log of the marker molecular weights revealed good linearity with a correlation coefficient R2 value of 0.9965, indicating that the M&R LE protein marker displays high accuracy for determining protein molecular weights. This accurate, regular and auto-detected M&R LE protein marker may provide a simple, efficient and economical tool for protein analysis.
NASA Astrophysics Data System (ADS)
Al-Kuhali, K.; Hussain M., I.; Zain Z., M.; Mullenix, P.
2015-05-01
Aim: This paper contribute to the flat panel display industry it terms of aggregate production planning. Methodology: For the minimization cost of total production of LCD manufacturing, a linear programming was applied. The decision variables are general production costs, additional cost incurred for overtime production, additional cost incurred for subcontracting, inventory carrying cost, backorder costs and adjustments for changes incurred within labour levels. Model has been developed considering a manufacturer having several product types, which the maximum types are N, along a total time period of T. Results: Industrial case study based on Malaysia is presented to test and to validate the developed linear programming model for aggregate production planning. Conclusion: The model development is fit under stable environment conditions. Overall it can be recommended to adapt the proven linear programming model to production planning of Malaysian flat panel display industry.
Schmidtmann, Gunnar; Jennings, Ben J; Bell, Jason; Kingdom, Frederick A A
2015-01-01
Previous studies investigating signal integration in circular Glass patterns have concluded that the information in these patterns is linearly summed across the entire display for detection. Here we test whether an alternative form of summation, probability summation (PS), modeled under the assumptions of Signal Detection Theory (SDT), can be rejected as a model of Glass pattern detection. PS under SDT alone predicts that the exponent β of the Quick- (or Weibull-) fitted psychometric function should decrease with increasing signal area. We measured spatial integration in circular, radial, spiral, and parallel Glass patterns, as well as comparable patterns composed of Gabors instead of dot pairs. We measured the signal-to-noise ratio required for detection as a function of the size of the area containing signal, with the remaining area containing dot-pair or Gabor-orientation noise. Contrary to some previous studies, we found that the strength of summation never reached values close to linear summation for any stimuli. More importantly, the exponent β systematically decreased with signal area, as predicted by PS under SDT. We applied a model for PS under SDT and found that it gave a good account of the data. We conclude that probability summation is the most likely basis for the detection of circular, radial, spiral, and parallel orientation-defined textures.
A single pH fluorescent probe for biosensing and imaging of extreme acidity and extreme alkalinity.
Chao, Jian-Bin; Wang, Hui-Juan; Zhang, Yong-Bin; Li, Zhi-Qing; Liu, Yu-Hong; Huo, Fang-Jun; Yin, Cai-Xia; Shi, Ya-Wei; Wang, Juan-Juan
2017-07-04
A simple tailor-made pH fluorescent probe 2-benzothiazole (N-ethylcarbazole-3-yl) hydrazone (Probe) is facilely synthesized by the condensation reaction of 2-hydrazinobenzothiazole with N-ethylcarbazole-3-formaldehyde, which is a useful fluorescent probe for monitoring extremely acidic and alkaline pH, quantitatively. The pH titrations indicate that Probe displays a remarkable emission enhancement with a pK a of 2.73 and responds linearly to minor pH fluctuations within the extremely acidic range of 2.21-3.30. Interestingly, Probe also exhibits strong pH-dependent characteristics with pK a 11.28 and linear response to extreme-alkalinity range of 10.41-12.43. In addition, Probe shows a large Stokes shift of 84 nm under extremely acidic and alkaline conditions, high selectivity, excellent sensitivity, good water-solubility and fine stability, all of which are favorable for intracellular pH imaging. The probe is further successfully applied to image extremely acidic and alkaline pH values fluctuations in E. coli cells. Copyright © 2017 Elsevier B.V. All rights reserved.
Healing in Unconsolidated Granular Earth Materials: a Mechanistic Theory
NASA Astrophysics Data System (ADS)
Lieou, C.; Daub, E. G.; Ecke, R. E.; Johnson, P. A.
2017-12-01
Abstract: Rock materials often display long-time relaxation, commonly termed aging or ``slow dynamics'', after the cessation of acoustic perturbations. In this presentation, we focus on unconsolidated rock materials and propose to explain such nonlinear relaxation through the Shear-Transformation-Zone (STZ) theory of granular media, adapted for small stresses and strains. The theory attributes the observed relaxation to the slow change of positions of constituent grains, and posits that the aging process can be described in three stages: fast recovery before some characteristic time associated with the fast nonlinear plasticity carriers, log-linear recovery of the elastic modulus at intermediate times, and gradual turnover to equilibrium steady-state behavior at long times. We demonstrate good agreement with experiments on aging in granular materials such as simulated fault gouge after an external disturbance.
NASA Astrophysics Data System (ADS)
Wang, Mingjun; Fang, Guojia; Yuan, Longyan; Huang, Huihui; Sun, Zhenhua; Liu, Nishuang; Xia, Shanhong; Zhao, Xingzhong
2009-05-01
The electrochromic (EC) property of WO3 nanoparticles grown on vertically self-aligned ZnO nanorods (ZNRs) is reported. An electrochromic character display based on WO3 nanoparticle-modified ZnO nanorod arrays on a flexible substrate has been fabricated and demonstrated. The ZNRs were first synthesized on ZnO-seed-coated In2O3:Sn (ITO) glass (1 cm2 cell) and polyethylene terephthalate (PET) (4 cm2 cell) substrates by a low temperature hydrothermal method, and then amorphous WO3 nanoparticles were grown directly on the surface of the ZNRs by the pulsed laser deposition (PLD) method. The ZNR-based EC device shows high transparence, good electrochromic stability and fast switching speed (4.2 and 4 s for coloration and bleaching, respectively, for a 1 cm2 cell). The good performance of the ZNR electrode-based EC display can be attributed to the large surface area, high crystallinity and good electron transport properties of the ZNR arrays. Its high contrast, fast switching, good memory and flexible characteristics indicate it is a promising candidate for flexible electrochromic displays or electronic paper.
Non-enzymatic detection of glucose using poly(azure A)-nickel modified glassy carbon electrode.
Liu, Tong; Luo, Yiqun; Zhu, Jiaming; Kong, Liyan; Wang, Wen; Tan, Liang
2016-08-15
A simple, sensitive and selective non-enzymatic glucose sensor was constructed in this paper. The poly(azure A)-nickel modified glassy carbon electrode was successfully fabricated by the electropolymerization of azure A and the adsorption of Ni(2+). The Ni modified electrode, which was characterized by scanning electron microscope, cyclic voltammetry, electrochemical impedance spectra and X-ray photoelectron spectroscopy measurements, respectively, displayed well-defined current responses of the Ni(III)/Ni(II) couple and showed a good activity for electrocatalytic oxidation of glucose in alkaline medium. Under the optimized conditions, the developed sensor exhibited a broad linear calibration range of 5 μM-12mM for quantification of glucose and a low detection limit of 0.64μM (3σ). The excellent analytical performance including simple structure, fast response time, good anti-interference ability, satisfying stability and reliable reproducibility were also found from the proposed amperometric sensor. The results were satisfactory for the determination of glucose in human serum samples as comparison to those from a local hospital. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Yaxi; Gao, Zongjun; Wu, Ri; Wang, Zhenhua; Chen, Xiangfeng; Chan, T-W Dominic
2017-01-06
In this work, magnetic porous carbon material derived from a bimetallic metal-organic framework was explored as an adsorbent for magnetic solid-phase extraction of organochlorine pesticides (OCPs). The synthesized porous carbon possessed a high specific surface area and magnetization saturation. The OCPs in the samples were quantified using gas chromatography coupled with a triple quadrupole mass spectrometer. The experimental parameters, including the desorption solvent and conditions, amount of adsorbent, extraction time, extraction temperature, and ionic strength of the solution, were optimized. Under optimal conditions, the developed method displayed good linearity (r>0.99) within the concentration range of 2-500ngL -1 . Low limits of detection (0.39-0.70ngL -1 , signal-to-noise ratio=3:1) and limits of quantification (1.45-2.0ngL -1 , signal-to-noise ratio=10:1) as well as good precision (relative standard deviation<10%) were also obtained. The developed method was applied in the analysis of OCPs in drinking and environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Moura, R. C.; Mengaldo, G.; Peiró, J.; Sherwin, S. J.
2017-02-01
We present estimates of spectral resolution power for under-resolved turbulent Euler flows obtained with high-order discontinuous Galerkin (DG) methods. The '1% rule' based on linear dispersion-diffusion analysis introduced by Moura et al. (2015) [10] is here adapted for 3D energy spectra and validated through the inviscid Taylor-Green vortex problem. The 1% rule estimates the wavenumber beyond which numerical diffusion induces an artificial dissipation range on measured energy spectra. As the original rule relies on standard upwinding, different Riemann solvers are tested. Very good agreement is found for solvers which treat the different physical waves in a consistent manner. Relatively good agreement is still found for simpler solvers. The latter however displayed spurious features attributed to the inconsistent treatment of different physical waves. It is argued that, in the limit of vanishing viscosity, such features might have a significant impact on robustness and solution quality. The estimates proposed are regarded as useful guidelines for no-model DG-based simulations of free turbulence at very high Reynolds numbers.
Extracting the Data From the LCM vk4 Formatted Output File
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelberger, James G.
These are slides about extracting the data from the LCM vk4 formatted output file. The following is covered: vk4 file produced by Keyence VK Software, custom analysis, no off the shelf way to read the file, reading the binary data in a vk4 file, various offsets in decimal lines, finding the height image data, directly in MATLAB, binary output beginning of height image data, color image information, color image binary data, color image decimal and binary data, MATLAB code to read vk4 file (choose a file, read the file, compute offsets, read optical image, laser optical image, read and computemore » laser intensity image, read height image, timing, display height image, display laser intensity image, display RGB laser optical images, display RGB optical images, display beginning data and save images to workspace, gamma correction subroutine), reading intensity form the vk4 file, linear in the low range, linear in the high range, gamma correction for vk4 files, computing the gamma intensity correction, observations.« less
Gageostatins A–C, Antimicrobial Linear Lipopeptides from a Marine Bacillus subtilis
Tareq, Fakir Shahidullah; Lee, Min Ah; Lee, Hyi-Seung; Lee, Jong-Seok; Lee, Yeon-Ju; Shin, Hee Jae
2014-01-01
Concerning the requirements of effective drug candidates to combat against high rising multidrug resistant pathogens, we isolated three new linear lipopeptides, gageostatins A–C (1–3), consisting of hepta-peptides and new 3-β-hydroxy fatty acids from the fermentation broth of a marine-derived bacterium Bacillus subtilis. Their structures were elucidated by analyzing a combination of extensive 1D, 2D NMR spectroscopic data and high resolution ESIMS data. Fatty acids, namely 3-β-hydroxy-11-methyltridecanoic and 3-β-hydroxy-9,11-dimethyltridecanoic acids were characterized in lipopeptides 1 and 2, respectively, whereas an unsaturated fatty acid (E)-7,9-dimethylundec-2-enoic acid was assigned in 3. The 3R configuration of the stereocenter of 3-β-hydroxy fatty acids in 1 and 2 was established by Mosher’s MTPA method. The absolute stereochemistry of amino acid residues in 1–3 was ascertained by acid hydrolysis followed by Marfey’s derivatization studies. Gageostatins 1–3 exhibited good antifungal activities with MICs values of 4–32 µg/mL when tested against pathogenic fungi (R. solani, B. cinerea and C. acutatum) and moderate antibacterial activity against bacteria (B. subtilis, S. aeureus, S. typhi and P. aeruginosa) with MICs values of 8–64 µg/mL. Futhermore, gageostatins 1–3 displayed cytotoxicity against six human cancer cell lines with GI50 values of 4.6–19.6 µg/mL. It is also noteworthy that mixed compounds 1+2 displayed better antifungal and cytotoxic activities than individuals. PMID:24492520
Almeida, S A A; Heitor, A M; Montenegro, M C B S M; Sales, M G F
2011-09-15
Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade(-1) and detection limits of 3.91×10(-5) mol L(-1). The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7-62.0 mV decade(-1) and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2-7. The sensors displayed fast response, always <15s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs. Copyright © 2011 Elsevier B.V. All rights reserved.
Articular Cartilage Repair Through Muscle Cell-Based Tissue Engineering
2011-03-01
defects display good cell survival and can differentiate into chondrocytes that improve the healing of articular cartilage. We also have observed that... self -renewal to their regenerative capacity after transplantation into the cartilage defects (Technical Objective #1). Next, we will determine the...osteochondral defects display good cell survival and can differentiate into chondrocytes that improve the healing of articular cartilage. We also have
Sagasti, Ariane; Bouropoulos, Nikolaos; Kouzoudis, Dimitris; Panagiotopoulos, Apostolos; Topoglidis, Emmanuel; Gutiérrez, Jon
2017-07-25
In the present work, a nanostructured ZnO layer was synthesized onto a Metglas magnetoelastic ribbon to immobilize hemoglobin (Hb) on it and study the Hb's electrochemical behavior towards hydrogen peroxide. Hb oxidation by H₂O₂ was monitored simultaneously by two different techniques: Cyclic Voltammetry (CV) and Magnetoelastic Resonance (MR). The Metglas/ZnO/Hb system was simultaneously used as a working electrode for the CV scans and as a magnetoelastic sensor excited by external coils, which drive it to resonance and interrogate it. The ZnO nanoparticles for the ZnO layer were grown hydrothermally and fully characterized by X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) and photoluminescence (PL). Additionally, the ZnO layer's elastic modulus was measured using a new method, which makes use of the Metglas substrate. For the detection experiments, the electrochemical cell was performed with a glass vial, where the three electrodes (working, counter and reference) were immersed into PBS (Phosphate Buffer Solution) solution and small H₂O₂ drops were added, one at a time. CV scans were taken every 30 s and 5 min after the addition of each drop and meanwhile a magnetoelastic measurement was taken by the external coils. The CV plots reveal direct electrochemical behavior of Hb and display good electrocatalytic response to the reduction of H₂O₂. The measured catalysis currents increase linearly with the H₂O₂ concentration in a wide range of 25-350 μM with a correlation coefficient 0.99. The detection limit is 25-50 μM. Moreover, the Metglas/ZnO/Hb electrode displays rapid response (30 s) to H₂O₂, and exhibits good stability and reproducibility of the measurements. On the other hand, the magnetoelastic measurements show a small linear mass increase versus the H₂O₂ concentration with a slope of 152 ng/μM, which is probably due to H₂O₂ adsorption in ZnO during the electrochemical reaction. No such effects were detected during the control experiment when only PBS solution was present for a long time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kimpe, T; Marchessoux, C; Rostang, J
Purpose: Use of color images in medical imaging has increased significantly the last few years. As of today there is no agreed standard on how color information needs to be visualized on medical color displays, resulting into large variability of color appearance and it making consistency and quality assurance a challenge. This paper presents a proposal for an extension of DICOM GSDF towards color. Methods: Visualization needs for several color modalities (multimodality imaging, nuclear medicine, digital pathology, quantitative imaging applications…) have been studied. On this basis a proposal was made for desired color behavior of color medical display systems andmore » its behavior and effect on color medical images was analyzed. Results: Several medical color modalities could benefit from perceptually linear color visualization for similar reasons as why GSDF was put in place for greyscale medical images. An extension of the GSDF (Greyscale Standard Display Function) to color is proposed: CSDF (color standard display function). CSDF is based on deltaE2000 and offers a perceptually linear color behavior. CSDF uses GSDF as its neutral grey behavior. A comparison between sRGB/GSDF and CSDF confirms that CSDF significantly improves perceptual color linearity. Furthermore, results also indicate that because of the improved perceptual linearity, CSDF has the potential to increase perceived contrast of clinically relevant color features. Conclusion: There is a need for an extension of GSDF towards color visualization in order to guarantee consistency and quality. A first proposal (CSDF) for such extension has been made. Behavior of a CSDF calibrated display has been characterized and compared with sRGB/GSDF behavior. First results indicate that CSDF could have a positive influence on perceived contrast of clinically relevant color features and could offer benefits for quantitative imaging applications. Authors are employees of Barco Healthcare.« less
Animated Displays IV: Linear Polarization.
ERIC Educational Resources Information Center
Chagnon, Paul
1993-01-01
Describes several demonstrations that can be easily reproduced to help students understand optical polarization. Displays and supplement text include polarization by reflection; polarization by scattering; liquid crystals; optical activity; calcite; birefringent plastics; retardation plates; photoelasticity; and the "Optical Barber…
Using Optimization to Improve Test Planning
2017-09-01
friendly and to display the output differently, the test and evaluation test schedule optimization model would be a good tool for the test and... evaluation schedulers. 14. SUBJECT TERMS schedule optimization, test planning 15. NUMBER OF PAGES 223 16. PRICE CODE 17. SECURITY CLASSIFICATION OF...make the input more user-friendly and to display the output differently, the test and evaluation test schedule optimization model would be a good tool
Development of a multipurpose scaffold for the display of peptide loops
Rossmann, Maxim; J. Greive, Sandra; Moschetti, Tommaso; Dinan, Michael
2017-01-01
Abstract Protein–protein interactions (PPIs) determine a wide range of biological processes and analysis of these dynamic networks is increasingly becoming a mandatory tool for studying protein function. Using the globular ATPase domain of recombinase RadA as a scaffold, we have developed a peptide display system (RAD display), which allows for the presentation of target peptides, protein domains or full-length proteins and their rapid recombinant production in bacteria. The design of the RAD display system includes differently tagged versions of the scaffold, which allows for flexibility in the protein purification method, and chemical coupling for small molecule labeling or surface immobilization. When combined with the significant thermal stability of the RadA protein, these features create a versatile multipurpose scaffold system. Using various orthogonal biophysical techniques, we show that peptides displayed on the scaffold bind to their natural targets in a fashion similar to linear parent peptides. We use the examples of CK2β/CK2α kinase and TPX2/Aurora A kinase protein complexes to demonstrate that the peptide displayed by the RAD scaffold can be used in PPI studies with the same binding efficacy but at lower costs compared with their linear synthetic counterparts. PMID:28444399
Inoue, Masaharu; Kihara, Kazunori; Yoshida, Soichiro; Ito, Masaya; Takeshita, Hideki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa
2015-01-01
Patients' use of a head-mounted display during their sonographic examinations could provide them with information about their diseases in real time and might help improve "patient-centered care." We conducted this prospective study to evaluate the feasibility of a modern head-mounted display for patient self-monitoring of sonographic examinations. In November and December 2013, 58 patients were enrolled. Patients wore a head-mounted display (HMZ-T2; Sony Corporation, Tokyo, Japan) during their sonographic examinations and watched their own images in real time. After the sonographic examinations, the patients completed a questionnaire, in which they evaluated the utility of the head-mounted display, their understanding of their diseases, their satisfaction with using the head-mounted display, and any adverse events. Until November 26, 2013, patients' names were requested on the questionnaire; after that date, the questionnaire was changed to be anonymous. Of the 58 patients, 56 (97%) elected to participate in this study. The head-mounted display was reported to have good image quality by 42 patients (75%) and good wearability by 39 (70%). Thirty-six patients (64%) reported they had deepened their understanding of their diseases. There were no major complications, and only 2 patients (4%) had mild eye fatigue. There was no significant association between questionnaire results and patient characteristics. None of the questionnaire results changed significantly after the questionnaire was made anonymous. The use of a modern head-mounted display by patients during sonographic examinations provided good image quality with acceptable wearability. It could deepen their understanding of their diseases and help develop patient-centered care. © 2015 by the American Institute of Ultrasound in Medicine.
Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays
NASA Astrophysics Data System (ADS)
Wahl, A.; Dawson, K.; Sassiat, N.; Quinn, A. J.; O'Riordan, A.
2011-08-01
This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.
Neuromuscular Control of Rapid Linear Accelerations in Fish
2016-06-22
2014 30-Apr-2015 Approved for Public Release; Distribution Unlimited Final Report: Neuromuscular Control of Rapid Linear Accelerations in Fish The...it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. Tufts University Research... Control of Rapid Linear Accelerations in Fish Report Title In this project, we measured muscle activity, body movements, and flow patterns during linear
NASA Astrophysics Data System (ADS)
Ganeshkumar, Rajasekaran; Sopiha, Kostiantyn V.; Wu, Ping; Cheah, Chin Wei; Zhao, Rong
2016-09-01
By virtue of its non-toxicity, high T c, and non-linear optical and ferroelectric properties, one-dimensional (1D) potassium niobate (KNbO3) may enable the development of numerous nanoscale devices. Despite the progress in 1D perovskite materials, preparing high aspect ratio KNbO3 nanostructures is still a concern. This report presents the successful synthesis of ultra-long KNbO3 nanofibers using a simple sol-gel assisted far-field electrospinning process. At optimized conditions, centimeters long, orthorhombic KNbO3 nanofibers with an average diameter of 100 nm have been obtained. The nanofibers are composed of uniform grains densely stacked along the direction of the nanofiber axis. Due to large surface-volume ratio, a high sensitive humidity nanosensor based on KNbO3 nanofibers displaying a logarithmic-linear dependence behavior of the conductance with the relative humidity (RH) was demonstrated. The conductance increases dramatically from 10-10 ℧ to 10-6 ℧ while RH varies from 15% to 95% at room temperature. In addition, the nanosensor exhibits excellent sensing performance, including ultrafast response (≤2 s) and recovery times (≤10 s), good linearity and reproducibility. Furthermore, the change in ferroelectric coercivity with respect to the RH and its effect in the sensing behavior were unveiled. This work could enable broad applications in the fields of environmental sensing and nano-electrical-mechanical systems.
Interactive Classroom Graphics--Simulating Non-Linear Arrhenius Plots.
ERIC Educational Resources Information Center
Ben-Zion, M.; Hoz, S.
1980-01-01
Describes two simulation programs using an interactive graphic display terminal that were developed for a course in physical organic chemistry. Demonstrates the energetic conditions that give rise to deviations from linearity in the Arrhenius equation. (CS)
Lin, Yi-Chieh; Chen, Bing-Mae; Lu, Wei-Cheng; Su, Chien-I; Prijovich, Zeljko M.; Chung, Wen-Chuan; Wu, Pei-Yu; Chen, Kai-Chuan; Lee, I-Chiao; Juan, Ting-Yi; Roffler, Steve R.
2013-01-01
Membrane-tethered proteins (mammalian surface display) are increasingly being used for novel therapeutic and biotechnology applications. Maximizing surface expression of chimeric proteins on mammalian cells is important for these applications. We show that the cytoplasmic domain from the B7-1 antigen, a commonly used element for mammalian surface display, can enhance the intracellular transport and surface display of chimeric proteins in a Sar1 and Rab1 dependent fashion. However, mutational, alanine scanning and deletion analysis demonstrate the absence of linear ER export motifs in the B7 cytoplasmic domain. Rather, efficient intracellular transport correlated with the presence of predicted secondary structure in the cytoplasmic tail. Examination of the cytoplasmic domains of 984 human and 782 mouse type I transmembrane proteins revealed that many previously identified ER export motifs are rarely found in the cytoplasmic tail of type I transmembrane proteins. Our results suggest that efficient intracellular transport of B7 chimeric proteins is associated with the structure rather than to the presence of a linear ER export motif in the cytoplasmic tail, and indicate that short (less than ~ 10-20 amino acids) and unstructured cytoplasmic tails should be avoided to express high levels of chimeric proteins on mammalian cells. PMID:24073236
Bringing Text Display Digital Radio to Consumers with Hearing Loss
ERIC Educational Resources Information Center
Sheffield, Ellyn G.; Starling, Michael; Schwab, Daniel
2011-01-01
Radio is migrating to digital transmission, expanding its offerings to include captioning for individuals with hearing loss. Text display radio requires a large amount of word throughput with minimal screen display area, making good user interface design crucial to its success. In two experiments, we presented hearing, hard-of-hearing, and deaf…
Three dimensional tracking with misalignment between display and control axes
NASA Technical Reports Server (NTRS)
Ellis, Stephen R.; Tyler, Mitchell; Kim, Won S.; Stark, Lawrence
1992-01-01
Human operators confronted with misaligned display and control frames of reference performed three dimensional, pursuit tracking in virtual environment and virtual space simulations. Analysis of the components of the tracking errors in the perspective displays presenting virtual space showed that components of the error due to visual motor misalignment may be linearly separated from those associated with the mismatch between display and control coordinate systems. Tracking performance improved with several hours practice despite previous reports that such improvement did not take place.
Hierarchical tone mapping for high dynamic range image visualization
NASA Astrophysics Data System (ADS)
Qiu, Guoping; Duan, Jiang
2005-07-01
In this paper, we present a computationally efficient, practically easy to use tone mapping techniques for the visualization of high dynamic range (HDR) images in low dynamic range (LDR) reproduction devices. The new method, termed hierarchical nonlinear linear (HNL) tone-mapping operator maps the pixels in two hierarchical steps. The first step allocates appropriate numbers of LDR display levels to different HDR intensity intervals according to the pixel densities of the intervals. The second step linearly maps the HDR intensity intervals to theirs allocated LDR display levels. In the developed HNL scheme, the assignment of LDR display levels to HDR intensity intervals is controlled by a very simple and flexible formula with a single adjustable parameter. We also show that our new operators can be used for the effective enhancement of ordinary images.
Does linear separability really matter? Complex visual search is explained by simple search
Vighneshvel, T.; Arun, S. P.
2013-01-01
Visual search in real life involves complex displays with a target among multiple types of distracters, but in the laboratory, it is often tested using simple displays with identical distracters. Can complex search be understood in terms of simple searches? This link may not be straightforward if complex search has emergent properties. One such property is linear separability, whereby search is hard when a target cannot be separated from its distracters using a single linear boundary. However, evidence in favor of linear separability is based on testing stimulus configurations in an external parametric space that need not be related to their true perceptual representation. We therefore set out to assess whether linear separability influences complex search at all. Our null hypothesis was that complex search performance depends only on classical factors such as target-distracter similarity and distracter homogeneity, which we measured using simple searches. Across three experiments involving a variety of artificial and natural objects, differences between linearly separable and nonseparable searches were explained using target-distracter similarity and distracter heterogeneity. Further, simple searches accurately predicted complex search regardless of linear separability (r = 0.91). Our results show that complex search is explained by simple search, refuting the widely held belief that linear separability influences visual search. PMID:24029822
Generation of optical vortices with controllable topological charges and polarization patterns
NASA Astrophysics Data System (ADS)
Yang, Ching-Han; Fuh, Andy Ying-Guey
2017-02-01
We present a simple and flexible method of generating various vectorial vortex beams (VVBs) based on the scheme of double modulations from a single liquid crystal spatial light modulator (SLM). In this configuration, a half-wave plate (HWP) placed in front of the SLM is first used to control the weights of linear polarization components of incident light. Then, we respectively encode two orbital angular momentum (OAM) eigenstates displayed on each half of the SLM onto each of the linear components of light. This yields the generation of VVB fields spanned by a pair of linearly polarized OAM eigenstates. In order to convert polarization bases from the linear pair into another orthogonal pair, a quarter-wave plate (QWP) placed behind the SLM is used. This enables us to generate VVBs spanned by any pair of orthogonally polarized OAM eigenstates. Generally, the light states of polarization (SOP) can be presented as a geodesic path located on the plane perpendicular to the axis connecting the pair of bases used on the Poincaré sphere. The light property is adjustable depending on both slow axes of HWP and QWP, as well as via computer generated holograms. To validate generated beams, two measurement procedures are subsequently applied. First, Stokes polarimetry is used to measure the light SOP over the transverse plane. Next, a Shack-Hartmann wavefront sensor is used to measure the OAM charge. Both the simulated and experimental results are shown to be in a good qualitative agreement. In addition, both polarization patterns and OAM charges can be controlled independently using the proposed method.
Liu, Linlin; Ma, Qiang; Li, Yang; Liu, ZiPing; Su, Xingguang
2015-01-15
In this work, a novel facile signal-off electrochemiluminescence (ECL) biosensor has been developed for the determination of glucose based on the integration of chitosan (CHIT), CdTe quantum dots (CdTe QDs) and Au nanoparticles (Au NPs) on the glassy carbon electrode (GCE). Chitosan displays high water permeability, hydrophilic property, strong hydrogel ability and good adhesion to load the double nanoparticles to the glassy carbon electrode surfaces. Au NPs are efficient glucose oxidase (GOx)-mimickess to catalytically oxidize glucose, similar to the natural process. Upon the addition of glucose, the Au NPs catalyzed glucose to produce gluconic acid and hydrogen peroxide (H2O2) based on the consumption of dissolved oxygen (O2), which resulted in a quenching effect on the ECL emission. Therefore, the determination of glucose could be achieved by monitoring the signal-off ECL biosensor. Under the optimum conditions, the ECL intensity of CdTe QDs and the concentration of glucose have a good linear relationship in the range of 0.01-10 mmol L(-1). The limit of detection for glucose was 5.28 μmol L(-1) (S/N=3). The biosensor showed good sensitivity, selectivity, reproducibility and stability. The proposed biosensor has been employed for the detection of glucose in human serum samples with satisfactory results. Copyright © 2014 Elsevier B.V. All rights reserved.
Parks, David R; Roederer, Mario; Moore, Wayne A
2006-06-01
In immunofluorescence measurements and most other flow cytometry applications, fluorescence signals of interest can range down to essentially zero. After fluorescence compensation, some cell populations will have low means and include events with negative data values. Logarithmic presentation has been very useful in providing informative displays of wide-ranging flow cytometry data, but it fails to adequately display cell populations with low means and high variances and, in particular, offers no way to include negative data values. This has led to a great deal of difficulty in interpreting and understanding flow cytometry data, has often resulted in incorrect delineation of cell populations, and has led many people to question the correctness of compensation computations that were, in fact, correct. We identified a set of criteria for creating data visualization methods that accommodate the scaling difficulties presented by flow cytometry data. On the basis of these, we developed a new data visualization method that provides important advantages over linear or logarithmic scaling for display of flow cytometry data, a scaling we refer to as "Logicle" scaling. Logicle functions represent a particular generalization of the hyperbolic sine function with one more adjustable parameter than linear or logarithmic functions. Finally, we developed methods for objectively and automatically selecting an appropriate value for this parameter. The Logicle display method provides more complete, appropriate, and readily interpretable representations of data that includes populations with low-to-zero means, including distributions resulting from fluorescence compensation procedures, than can be produced using either logarithmic or linear displays. The method includes a specific algorithm for evaluating actual data distributions and deriving parameters of the Logicle scaling function appropriate for optimal display of that data. It is critical to note that Logicle visualization does not change the data values or the descriptive statistics computed from them. Copyright 2006 International Society for Analytical Cytology.
Xue, Mingyue; Zhang, Liangliang; Zhan, Zhihua; Zou, Mengbing; Huang, Yong; Zhao, Shulin
2016-04-01
A novel sulfur and nitrogen binary doped carbon dots (S,N-CDs) was synthesized by one-step manner through the hydrothermal treatment of citric acid (CA) and ammonium thiocyanate, and the procedures for biomedical applications, including probing doxycycline in living cells and multicolor cell imaging were developed. The obtained S,N-CDs are stable in aqueous solution, possess a very high quantum yield (QY, 74.15%) and good photostability. The fluorescence of S,N-CDs can be specifically quenched by doxycycline, providing a convenient turn-off assay of doxycycline. This assay shows a wide linear detection range from 0.08 to 60 μM with a low detection limit of 20 nM. The present method also displays a good selectivity. More importantly, the S,N-CDs have an excellent biocompatibility and low cytotoxicity, allowing the multicolor cell imaging and doxycycline detection in living cells. Consequently, the developed doxycycline methods is facile, low-cost, biocompatible, sensitive and selective, which may hold the potential applications in the fields of food safety and environmental monitoring, as well as cancer therapy and related mechanism research. Copyright © 2015 Elsevier B.V. All rights reserved.
Ponnaiah, Sathish Kumar; Prakash, Periakaruppan; Vellaichamy, Balakumar
2018-06-01
The novel N-CeO 2 nanoparticles decorated on reduced graphene oxide (N-CeO 2 @rGO) composite has been synthesized by sonochemical method. The characterization of as prepared nanocomposite was intensely performed by UV-Vis, FT-IR, EDX, FE-SEM, HR-TEM, XRD, and TGA analysis. The synthesized nanomaterial was further investigated for its selective and sensitive sensing of paracetamol (PM) based on a N-CeO 2 @rGO modified glassy carbon electrode. A distinct and improved reversible redox peak of PM is obtained at N-CeO 2 @rGO nanocomposite compared to the electrodes modified with N-CeO 2 and rGO. It displays a very good performance with a wide linear range of 0.05-0.600 μM, a very low detection limit of 0.0098 μM (S/N = 3), a high sensitivity of 268 μA µM -1 cm -2 and short response time (<3 s). Also, the fabricated sensor shows a good sensibleness for the detection of PM in various tablet samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhu, Wencai; Chen, Ting; Ma, Xuemei; Ma, Houyi; Chen, Shenhao
2013-11-01
Highly dispersed hollow gold-graphene (HAu-G) nanocomposites were synthesized by a two-step method. The immobilization of hollow gold nanoparticles (HAu NPs) onto the surface of graphene sheets was achieved by mixing an aqueous solution of HAu NPs with a poly(N-vinylpyrrolidone)-functionalized graphene dispersion at room temperature. A glassy carbon electrode (GCE) was modified with the nanocomposites, and the as-prepared modified electrode displayed high electrocatalytic activity and extraordinary electronic transport properties. Amperometric detection of dopamine (DA) performed with the HAu-G modified electrode exhibits a good linearity between 0.08 and 600 μM with a low detection limit of 0.05 μM (S/N=3) and also possesses good reproducibility and operational stability. The interference of ascorbic acid (AA) and uric acid (UA) can be excluded when using differential pulse voltammetric technique. In addition, this type of modified electrode can also be applied to the determination of DA content in dopamine hydrochloride injection. It is obvious that the HAu-G modified electrode provides a new way to detect dopamine sensitively and selectively. Copyright © 2013 Elsevier B.V. All rights reserved.
Li, Haixia; Dong, Hao; Yu, Mingming; Liu, Chunxia; Li, Zhanxian; Wei, Liuhe; Sun, Ling-Dong; Zhang, Hongyan
2017-09-05
It is crucial for cell physiology to keep the homeostasis of pH, and it is highly demanded yet challenging to develop luminescence resonance energy transfer (LRET)-based near-infrared (NIR) ratiometric luminescent sensor for the detection of pH fluctuation with NIR excitation. As promising energy donors for LRET, upconversion nanoparticles (UCNPs) have been widely used to fabricate nanosensors, but the relatively low LRET efficiency limits their application in bioassay. To improve the LRET efficiency, core/shell/shell structured β-NaGdF 4 @NaYF 4 :Yb,Tm@NaYF 4 UCNPs were prepared and decorated with hemicyanine dyes as an LRET-based NIR ratiometric luminescent pH fluctuation-nanosensor for the first time. The as-developed nanosensor not only exhibits good antidisturbance ability, but it also can reversibly sense pH and linearly sense pH in a range of 6.0-9.0 and 6.8-9.0 from absorption and upconversion emission spectra, respectively. In addition, the nanosensor displays low dark toxicity under physiological temperature, indicating good biocompatibility. Furthermore, live cell imaging results revealed that the sensor can selectively monitor pH fluctuation via ratiometric upconversion luminescence behavior.
NASA Astrophysics Data System (ADS)
Reddy, Y. Ashok Kumar; Shin, Young Bong; Kang, In-Ku; Lee, Hee Chul
2018-03-01
The present study directly addresses the improved bolometric properties by means of different Nb doping concentrations into TiO2- x films. The x-ray diffraction patterns do not display any obvious diffraction peaks, suggesting that all the films deposited at room temperature had an amorphous structure. A small binding energy shift was observed in x-ray photo electron spectroscopy due to the change of chemical composition with Nb doping concentration. All the device samples exhibit linear I- V characteristics, which attests to the formation of good ohmic contact with low contact resistance between the Nb:TiO2- x (TNO) film and the electrode (Ti) material. The performance of the bolometric material can be evaluated through the temperature coefficient of resistance (TCR), and the absolute value of TCR was found to be increased from 2.54% to 2.78% with increasing the Nb doping concentration. The voltage spectral density of 1/ f noise was measured in the frequency range of 1-60 Hz and found to be decreased with increase of Nb doping concentration. As a result, for 1 at.% Nb-doped TNO sample exhibits improved bolometric properties towards the good infrared image sensor device.
Zaidi, Shabi Abbas
2017-08-15
This work demonstrates the facile and efficient preparation protocol of β-Cyclodextrin-reduced graphene oxide modified glassy carbon electrode (β-CD/RGO/GCE) sensor for an impressive chiral selectivity analysis for phenylalanine enantiomers. In this work, the immobilization of β-CD over graphene sheets allows the excellent enantiomer recognition due to the large surface area and high conductivity of graphene sheets and extraordinary supramolecular (host-guest interaction) property of β-CD. The proposed sensor was well characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and electrochemical impedance spectroscopy (EIS) techniques. The analytical studies demonstrated that the β-CD/RGO/GCE exhibit superior chiral recognition toward L-phenylalanine as compared to D-phenylalanine. Under optimum conditions, the developed sensor displayed a good linear range from 0.4 to 40µM with the limit of detection (LOD) values of 0.10µM and 0.15µM for l- and D-phenylalanine, respectively. Furthermore, the proposed sensor exhibits good stability and regeneration capacity. Thus, the as-synthesized material can be exploited for electrochemical enantiomer recognition successfully. Copyright © 2017 Elsevier B.V. All rights reserved.
Categorization and identification of simultaneous targets.
Theeuwes, J
1991-02-01
Early and late selection theories of visual attention disagree about whether identification occurs before or after selection. Studies showing the category effect, i.e., the time to detect a letter is hardly affected by the number of digits present in the display, are taken as evidence for late selection theories since these studies suggest parallel identification of all items in the display. As an extension of previous studies, in the present study two categorically different targets were presented simultaneously among a variable number of nontargets. Subjects were shown brief displays of two target letters among either 2, 4 or 6 nontarget digits. Subjects responded 'same' when the two letters were identical and 'different' otherwise. Since the 'same-different' response reflects the combined outcome of the simultaneous targets, late-selection theory predicts that the time to match the target letters is independent of the number of nontarget digits. Alternatively, early-selection theory predicts a linear increase of reaction time with display size since the presence of more than one target disrupts parallel preattentive processing, leading to a serial search through all items in the display. The results provide evidence for the early-selection view since reaction time increased linearly with the number of categorically different nontargets. A control experiment revealed that none of the alternative explanations could account for the display size effect.
A manual control theory analysis of vertical situation displays for STOL aircraft
NASA Technical Reports Server (NTRS)
Baron, S.; Levison, W. H.
1973-01-01
Pilot-vehicle-display systems theory is applied to the analysis of proposed vertical situation displays for manual control in approach-to-landing of a STOL aircraft. The effects of display variables on pilot workload and on total closed-loop system performance was calculated using an optimal-control model for the human operator. The steep approach of an augmentor wing jet STOL aircraft was analyzed. Both random turbulence and mean-wind shears were considered. Linearized perturbation equations were used to describe longitudinal and lateral dynamics of the aircraft. The basic display configuration was one that abstracted the essential status information (including glide-slope and localizer errors) of an EADI display. Proposed flight director displays for both longitudinal and lateral control were also investigated.
Holographic and light-field imaging for augmented reality
NASA Astrophysics Data System (ADS)
Lee, Byoungho; Hong, Jong-Young; Jang, Changwon; Jeong, Jinsoo; Lee, Chang-Kun
2017-02-01
We discuss on the recent state of the augmented reality (AR) display technology. In order to realize AR, various seethrough three-dimensional (3D) display techniques have been reported. We describe the AR display with 3D functionality such as light-field display and holography. See-through light-field display can be categorized by the optical elements which are used for see-through property: optical elements controlling path of the light-fields and those generating see-through light-field. Holographic display can be also a good candidate for AR display because it can reconstruct wavefront information and provide realistic virtual information. We introduce the see-through holographic display using various optical techniques.
ELM: the status of the 2010 eukaryotic linear motif resource
Gould, Cathryn M.; Diella, Francesca; Via, Allegra; Puntervoll, Pål; Gemünd, Christine; Chabanis-Davidson, Sophie; Michael, Sushama; Sayadi, Ahmed; Bryne, Jan Christian; Chica, Claudia; Seiler, Markus; Davey, Norman E.; Haslam, Niall; Weatheritt, Robert J.; Budd, Aidan; Hughes, Tim; Paś, Jakub; Rychlewski, Leszek; Travé, Gilles; Aasland, Rein; Helmer-Citterich, Manuela; Linding, Rune; Gibson, Toby J.
2010-01-01
Linear motifs are short segments of multidomain proteins that provide regulatory functions independently of protein tertiary structure. Much of intracellular signalling passes through protein modifications at linear motifs. Many thousands of linear motif instances, most notably phosphorylation sites, have now been reported. Although clearly very abundant, linear motifs are difficult to predict de novo in protein sequences due to the difficulty of obtaining robust statistical assessments. The ELM resource at http://elm.eu.org/ provides an expanding knowledge base, currently covering 146 known motifs, with annotation that includes >1300 experimentally reported instances. ELM is also an exploratory tool for suggesting new candidates of known linear motifs in proteins of interest. Information about protein domains, protein structure and native disorder, cellular and taxonomic contexts is used to reduce or deprecate false positive matches. Results are graphically displayed in a ‘Bar Code’ format, which also displays known instances from homologous proteins through a novel ‘Instance Mapper’ protocol based on PHI-BLAST. ELM server output provides links to the ELM annotation as well as to a number of remote resources. Using the links, researchers can explore the motifs, proteins, complex structures and associated literature to evaluate whether candidate motifs might be worth experimental investigation. PMID:19920119
Wu, Lina; McIntosh, Mike; Zhang, Xueji; Ju, Huangxian
2007-12-15
Thionine had strong interaction with carbon nanofiber (CNF) and was used in the non-covalent functionalization of carbon nanofiber for the preparation of stable thionine-CNF nanocomposite with good dispersion. With a simple one-step electrochemical polymerization of thionine-CNF nanocomposite and alcohol oxidase (AOD), a stable poly(thionine)-CNF/AOD biocomposite film was formed on electrode surface. Based on the excellent catalytic activity of the biocomposite film toward reduction of dissolved oxygen, a sensitive ethanol biosensor was proposed. The ethanol biosensor could monitor ethanol ranging from 2.0 to 252 microM with a detection limit of 1.7 microM. It displayed a rapid response, an expanded linear response range as well as excellent reproducibility and stability. The combination of catalytic activity of CNF and the promising feature of the biocomposite with one-step non-manual technique favored the sensitive determination of ethanol with improved analytical capabilities.
Progressive transmission of road network
NASA Astrophysics Data System (ADS)
Ai, Bo; Ai, Tinghua; Tang, Xinming; Li, Zhen
2009-10-01
The progressive transmission of vector map data requires efficient multi-scale data model to process the data into hierarchical structure. This paper presents such a data structure of road network without redundancy of geometry for progressive transmission. For a given scale, the road network display has to settle two questions. One is which road objects to be represented and the other is what geometric details to be visualized for the selected roads. This paper combines the Töpfer law and the BLG-tree structure into a multi-scale representation matrix to answer simultaneously the above two questions. In the matrix, rows from top to bottom represent the roads in the sequence of descending classification of traffic and length, which can support the Töpfer law to retrieve the more important roads. In a row, columns record one road by a linear BLG-tree to provide good line graphics.
Huang, Chenxi; Huang, Hongxin; Toyoda, Haruyoshi; Inoue, Takashi; Liu, Huafeng
2012-11-19
We propose a new method for realizing high-spatial-resolution detection of singularity points in optical vortex beams. The method uses a Shack-Hartmann wavefront sensor (SHWS) to record a Hartmanngram. A map of evaluation values related to phase slope is then calculated from the Hartmanngram. The position of an optical vortex is determined by comparing the map with reference maps that are calculated from numerically created spiral phases having various positions. Optical experiments were carried out to verify the method. We displayed various spiral phase distribution patterns on a phase-only spatial light modulator and measured the resulting singularity point using the proposed method. The results showed good linearity in detecting the position of singularity points. The RMS error of the measured position of the singularity point was approximately 0.056, in units normalized to the lens size of the lenslet array used in the SHWS.
A Study on a Centralized Under-Voltage Load Shedding Scheme Considering the Load Characteristics
NASA Astrophysics Data System (ADS)
Deng, Jiyu; Liu, Junyong
Under-voltage load shedding is an important measure for maintaining voltage stability.Aiming at the optimal load shedding problem considering the load characteristics,firstly,the traditional under-voltage load shedding scheme based on a static load model may cause the analysis inaccurate is pointed out on the equivalent Thevenin circuit.Then,the dynamic voltage stability margin indicator is derived through local measurement.The derived indicator can reflect the voltage change of the key area in a myopia linear way.Dimensions of the optimal problem will be greatly simplified using this indicator.In the end,mathematical model of the centralized load shedding scheme is built with the indicator considering load characteristics.HSPPSO is introduced to slove the optimal problem.Simulation results on IEEE-39 system show that the proposed scheme display a good adaptability in solving the under-voltage load shedding considering dynamic load characteristics.
DSP Implementation of the Retinex Image Enhancement Algorithm
NASA Technical Reports Server (NTRS)
Hines, Glenn; Rahman, Zia-Ur; Jobson, Daniel; Woodell, Glenn
2004-01-01
The Retinex is a general-purpose image enhancement algorithm that is used to produce good visual representations of scenes. It performs a non-linear spatial/spectral transform that synthesizes strong local contrast enhancement and color constancy. A real-time, video frame rate implementation of the Retinex is required to meet the needs of various potential users. Retinex processing contains a relatively large number of complex computations, thus to achieve real-time performance using current technologies requires specialized hardware and software. In this paper we discuss the design and development of a digital signal processor (DSP) implementation of the Retinex. The target processor is a Texas Instruments TMS320C6711 floating point DSP. NTSC video is captured using a dedicated frame-grabber card, Retinex processed, and displayed on a standard monitor. We discuss the optimizations used to achieve real-time performance of the Retinex and also describe our future plans on using alternative architectures.
Optical and transport properties of dense liquid silica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, Tingting; Millot, Marius; Kraus, Richard G.
2015-06-15
Using density-functional-theory based molecular dynamics and the Kubo-Greenwood linear response theory, we evaluated the high-pressure equation of state and the optical and transport properties of quartz and fused silica shock-compressed to 2000 GPa. The computed Hugoniots and corresponding optical reflectivity values are in very good agreement with published data for quartz, and new data that we obtained on fused silica using magnetically launched flyer plate experiments. The rise of optical reflectivity upon shock compression appears to be primarily a temperature-driven mechanism, which is relatively insensitive to small density variation. We observed that the electrical conductivity does not display Drude-like frequencymore » dependence, especially at lower temperatures. In addition, the Wiedemann-Franz relation between electrical and thermal conductivities was found to be invalid. It suggests that even at three-fold compression, warm dense liquid silica on the Hugoniot curve is still far away from the degenerate limit.« less
Bridgman growth of large-aperture yttrium calcium oxyborate crystal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Anhua, E-mail: wuanhua@mail.sic.ac.cn; Jiang, Linwen; Qian, Guoxing
2012-09-15
Highlights: ► YCOB is a novel non-linear optical crystal possessing good thermal, mechanical and nonlinear optical properties. ► Large size crystal growth is key technology question for YCOB crystal. ► YCOB crystals 3 in. in diameter were grown with modified vertical Bridgman method. ► It is a more effective growth method to obtain large size and high quality YCOB crystal. -- Abstract: Large-aperture yttrium calcium oxyborate YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) crystals with 3 in. in diameter were grown with modified vertical Bridgman method, and the large crystal plate (63 mm × 68 mm × 20 mm) was harvested formore » high-average power frequency conversion system. The crack, facet growth and spiral growth can be effectively controlled in the as-grown crystal, and Bridgman method displays more effective in obtain large size and high quality YCOB crystal plate than Czochralski technique.« less
A Demo opto-electronic power source based on single-walled carbon nanotube sheets.
Hu, Chunhua; Liu, Changhong; Chen, Luzhuo; Meng, Chuizhou; Fan, Shoushan
2010-08-24
It is known that single-walled carbon nanotubes (SWNTs) strongly absorb light, especially in the near-infrared (NIR) region, and convert it into heat. In fact, SWNTs also have considerable ability to convert heat into electricity. In this work, we show that SWNT sheets made from as-grown SWNT arrays display a large positive thermoelectric coefficient (p-type). We designed a simple SWNT device to convert illuminating NIR light directly into a notable voltage output, which was verified by experimental tests. Furthermore, by a simple functionalization step, the p- to n-type transition was conveniently achieved for the SWNT sheets. By integrating p- and n-type elements in series, we constructed a novel NIR opto-electronic power source, which outputs a large voltage that sums over the output of every single element. Additionally, the output of the demo device has shown a good linear relationship with NIR light power density, favorable for IR sensors.
Sun, Yonghua; Zhang, Zhujun; Xi, Zhijun; Shi, Zuolong; Tian, Wei
2009-08-26
In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)(3)(2+) can be compensated by adding a small amount of Ru(bpy)(3)(2+) into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 x 10(-8) g mL(-1) to 1.0 x 10(-6) g mL(-1) and the detection limit was 3 x 10(-9) g mL(-1) (S/N=3). The as-prepared ECL detector displayed good sensitivity and stability.
Chen, Long; He, Linwei; Ma, Fuyin; Liu, Wei; Wang, Yaxing; Silver, Mark A; Chen, Lanhua; Zhu, Lin; Gui, Daxiang; Diwu, Juan; Chai, Zhifang; Wang, Shuao
2018-05-09
Real-time and accurate detection of pH in aqueous solution is of great significance in chemical, environmental, and engineering-related fields. We report here the use of 8-hydroxyquinoline-functionalized covalent organic framework (COF-HQ) for dual-mode pH sensing. In the fluorescent mode, the emission intensity of COF-HQ weakened as the pH decreased, and also displayed a good linear relationship against pH in the range from 1 to 5. In addition, COF-HQ showed discernible color changes from yellow to black as the acidity increased and can be therefore used as a colorimetric pH sensor. All these changes are reversible and COF-HQ can be recycled for multiple detection runs owing to its high hydrolytical stability. It can be further assembled into a mixed matrix membrane for practical applications.
Zhang, Lihua; Xu, Zhiai; Sun, Xuping; Dong, Shaojun
2007-01-15
Based on electrogenerated chemiluminescence (ECL), a novel method for fabrication of alcohol dehydrogenase (ADH) biosensor by self-assembling ADH to Ru(bpy)(3)(2+)-AuNPs aggregates (Ru-AuNPs) on indium tin oxide (ITO) electrode surface has been developed. Positively charged Ru(bpy)(3)(2+) could be immobilized stably on the electrode surface with negatively charged AuNPs in the form of aggregate via electrostatic interaction. On the other hand, AuNPs are favourable candidates for the immobilization of enzymes because amine groups and cysteine residues in the enzymes are known to bind strongly with AuNPs. Moreover, AuNPs can act as tiny conduction centers to facilitate the transfer of electrons. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate, and it displayed wide linear range, high sensitivity and good stability.
Wang, Wen-Cheng; Yan, Li-Jun; Shi, Fan; Niu, Xue-Liang; Huang, Guo-Lei; Zheng, Cai-Juan; Sun, Wei
2015-01-01
By using the hydrothermal method, carbon microspheres (CMS) were fabricated and used for electrode modification. The characteristics of CMS were investigated using various techniques. The biocompatible sensing platform was built by immobilizing hemoglobin (Hb) on the micrometer-sized CMS-modified electrode with a layer of chitosan membrane. On the cyclic voltammogram, a couple of quasi-reversible cathodic and anodic peaks appeared, showing that direct electrochemistry of Hb with the working electrode was achieved. The catalytic reduction peak currents of the bioelectrode to trichloroacetic acid was established in the linear range of 2.0~70.0 mmol·L−1 accompanied by a detection limit of 0.30 mmol·L−1 (3σ). The modified electrode displayed favorable sensitivity, good reproducibility and stability, which suggests that CMS is promising for fabricating third-generation bioelectrochemical sensors. PMID:26703621
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatum, J.L.; Burke, T.S.; Sugerman, H.T.
1982-04-01
Eleven patients with suspected adult respiratory distress syndrome (ARDS) and five control patients were studied using a computerized gamma imaging and analysis technique and /sup 99m/Tc-labeled human serum albumin. The heart and right lung were imaged, lung:heart ratio was plotted vs. time, and a linear regression was fitted to the data points displayed. The slope of this fit was termed the ''slope index.'' An index value of 2 standard deviations greater than the control mean was considered positive. Radiographs from the six positive studies revealed typical diffuse air-space disease. Radiographs from two of the five negative studies demonstrated air-space consolidation.more » Both of these patients had elevated pulmonary capillary wedge pressure, cardiomegaly, and clinical course consistent with cardiogenic pulmonary edema. These preliminary data demonstrated a good correlation between positive slope index and clinical ARDS.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatum, J.L.; Burke, T.S.; Sugerman, H.J.
1982-04-01
Eleven patients with suspected adult respiratory distress syndrome (ARDS) and five control patients were studied using a computerized gamma imaging and analysis technique and 99mTc-labeled human serum albumin. The heart and right lung were imaged, lung:heart ratio was plotted vs. time, and a linear regression was fitted to the data points displayed. The slope of this fit was termed the ''slope index.'' An index value of 2 standard deviations greater than the control mean was considered positive. Radiographs from the six positive studies revealed typical diffuse air-space disease. Radiographs from two of the five negative studies demonstrated air-space consolidation. Bothmore » of these patients had elevated pulmonary capillary wedge pressure, cardiomegaly, and clinical course consistent with cardiogenic pulmonary edema. These preliminary data demonstrated a good correlation between positive slope index and clinical ARDS.« less
Forecasting stochastic neural network based on financial empirical mode decomposition.
Wang, Jie; Wang, Jun
2017-06-01
In an attempt to improve the forecasting accuracy of stock price fluctuations, a new one-step-ahead model is developed in this paper which combines empirical mode decomposition (EMD) with stochastic time strength neural network (STNN). The EMD is a processing technique introduced to extract all the oscillatory modes embedded in a series, and the STNN model is established for considering the weight of occurrence time of the historical data. The linear regression performs the predictive availability of the proposed model, and the effectiveness of EMD-STNN is revealed clearly through comparing the predicted results with the traditional models. Moreover, a new evaluated method (q-order multiscale complexity invariant distance) is applied to measure the predicted results of real stock index series, and the empirical results show that the proposed model indeed displays a good performance in forecasting stock market fluctuations. Copyright © 2017 Elsevier Ltd. All rights reserved.
;Turn-on; fluorescent probe detection of Ca2 + ions and applications to bioimaging
NASA Astrophysics Data System (ADS)
Zhang, Huifang; Yin, Caixia; Liu, Tao; Zhang, Yongbin; Huo, Fangjun
2017-06-01
Ca2 + is intracellular divalent cation with the largest concentration variations and involved in many biological phenomena and often acted as a second messenger in signaling pathway. Therefore, the development of probes for specific Ca2 + detection is of great importance. Herein, a novel turn-on fluorescent probe for the detection of Ca2 + in MeCN-aqueous medium was designed and synthesized. The probe displayed responses to Ca2 + with a fluorescence enhancement at 525 nm, accompanying with a distinct fluorescence change from nearly colorless to bright yellow-green. Besides, the probe exhibited a rapid signal response time (within 25 s), a good linearity range and a lower detection limit (2.70 × 10- 7 M). In addition, the ability of the probe to detect Ca2 + in living cells (HeLa cells) via an enhancement of the fluorescence has also been demonstrated.
Li, Liang; Liang, Bo; Li, Feng; Shi, Jianguo; Mascini, Marco; Lang, Qiaolin; Liu, Aihua
2013-04-15
In this paper, we first report the construction of Nafion/glucose oxidase (GOD)/xylose dehydrogenase displayed bacteria (XDH-bacteria)/multiwalled carbon nanotubes (MWNTs) modified electrode for simultaneous voltammetric determination of D-glucose and D-xylose. The optimal conditions for the immobilized enzymes were established. Both enzymes retained their good stability and activities. In the mixture solution of D-glucose and D-xylose containing coenzyme NAD⁺ (the oxidized form of nicotinamide adenine dinucleotide), the Nafion/GOD/XDH-bacteria/MWNTs modified electrode exhibited quasi-reversible oxidation-reduction peak at -0.5 V (vs. saturated calomel electrode, SCE) originating from the catalytic oxidation of D-glucose, and oxidation peak at +0.55 V(vs. SCE) responding to the oxidation of NADH (the reduced form of nicotinamide adenine dinucleotide) by the carbon nanotubes, where NADH is the resultant product of coenzyme NAD⁺ involved in the catalysis of D-xylose by XDH-displayed bacteria. For the proposed biosensor, cathodic peak current at -0.5 V was linear with the concentration of D-glucose within the range of 0.25-6 mM with a low detection limit of 0.1 mM D-glucose (S/N=3), and the anodic peak current at +0.55 V was linear with the concentration of d-xylose in the range of 0.25∼4 mM with a low detection limit of 0.1 mM D-xylose (S/N=3). Further, D-xylose and D-glucose did not interfere with each other. 300-fold excess saccharides including D-maltose, D-galactose, D-mannose, D-sucrose, D-fructose, D-cellobiose, and 60-fold excess L-arabinose, and common interfering substances (100-fold excess ascorbic acid, dopamine, uric acid) as well as 300-fold excess D-xylitol did not affect the detection of D-glucose and D-xylose (both 1 mM). Therefore, the proposed biosensor is stable, specific, reproducible, simple, rapid and cost-effective, which holds great potential in real applications. Copyright © 2012 Elsevier B.V. All rights reserved.
Wagner, Barry T; Jackson, Heather M
2006-02-01
This study examined the cognitive demands of 2 selection techniques in augmentative and alternative communication (AAC), direct selection, and visual linear scanning, by determining the memory retrieval abilities of typically developing children when presented with fixed communication displays. One hundred twenty typical children from kindergarten, 1st, and 3rd grades were randomly assigned to either a direct selection or visual linear scanning group. Memory retrieval was assessed through word span using Picture Communication Symbols (PCSs). Participants were presented various numbers and arrays of PCSs and asked to retrieve them by placing identical graphic symbols on fixed communication displays with grid layouts. The results revealed that participants were able to retrieve more PCSs during direct selection than scanning. Additionally, 3rd-grade children retrieved more PCSs than kindergarten and 1st-grade children. An analysis on the type of errors during retrieval indicated that children were more successful at retrieving the correct PCSs than the designated location of those symbols on fixed communication displays. AAC practitioners should consider using direct selection over scanning whenever possible and account for anticipatory monitoring and pulses when scanning is used in the service delivery of children with little or no functional speech. Also, researchers should continue to investigate AAC selection techniques in relationship to working memory resources.
NASA Astrophysics Data System (ADS)
Zhang, Hui; Zhang, Ge; Xu, Jingkun; Wen, Yangping; Ming, Shouli; Zhang, Jie; Ding, Wanchuan
2018-02-01
Trivalent chromium (Cr3 +) can cause severely environment pollution, declining quality of edible agro-products in plants and animals, and human diseases. Poly(N-(9-fluorenylmethoxycarbonyl)-L-histidine) (PFLH) synthesized by the direct electro-polymerization of its corresponding commercially available monomer in both boron trifluoride diethyl etherate and dichloromethane mixed system. The ;turn-on; type fluorescent sensor based on PFLH displayed high sensitivity and selectivity for Cr3 + detecting. The structure of PFLH was rationally proved by 1H NMR spectra, FT-IR spectra, quantum chemical calculations, and its optical properties were characterized. The electro-synthesized PFLH exhibited a ;turn-on; fluorescent response towards Cr3 +, which was employed as a sensing platform for the ;turn-on; fluorescent analysis of Cr3 + in a wide linear range from 5.1 nM to 25 μM with a low limit of detection as low as 1.7 nM. The possible mechanism of fluorescent ;turn-on; sensor based on PFLH for Cr3 + was proposed. The sensor displayed high sensitivity, good selectivity, satisfactory practicability, suggesting that PFLH has potential fluorescent application for ;turn-on; sensing Cr3 + in agricultural environments and edible agro-products of plants and animals.
Lessons from Jurassic Park: patients as complex adaptive systems.
Katerndahl, David A
2009-08-01
With realization that non-linearity is generally the rule rather than the exception in nature, viewing patients and families as complex adaptive systems may lead to a better understanding of health and illness. Doctors who successfully practise the 'art' of medicine may recognize non-linear principles at work without having the jargon needed to label them. Complex adaptive systems are systems composed of multiple components that display complexity and adaptation to input. These systems consist of self-organized components, which display complex dynamics, ranging from simple periodicity to chaotic and random patterns showing trends over time. Understanding the non-linear dynamics of phenomena both internal and external to our patients can (1) improve our definition of 'health'; (2) improve our understanding of patients, disease and the systems in which they converge; (3) be applied to future monitoring systems; and (4) be used to possibly engineer change. Such a non-linear view of the world is quite congruent with the generalist perspective.
Frequency of Behavior Witnessed and Conformity in an Everyday Social Context
Claidière, Nicolas; Bowler, Mark; Brookes, Sarah; Brown, Rebecca; Whiten, Andrew
2014-01-01
Conformity is thought to be an important force in human evolution because it has the potential to stabilize cultural homogeneity within groups and cultural diversity between groups. However, the effects of such conformity on cultural and biological evolution will depend much on the particular way in which individuals are influenced by the frequency of alternative behavioral options they witness. In a previous study we found that in a natural situation people displayed a tendency to be ‘linear-conformist’. When visitors to a Zoo exhibit were invited to write or draw answers to questions on cards to win a small prize and we manipulated the proportion of text versus drawings on display, we found a strong and significant effect of the proportion of text displayed on the proportion of text in the answers, a conformist effect that was largely linear with a small non-linear component. However, although this overall effect is important to understand cultural evolution, it might mask a greater diversity of behavioral responses shaped by variables such as age, sex, social environment and attention of the participants. Accordingly we performed a further study explicitly to analyze the effects of these variables, together with the quality of the information participants' responses made available to further visitors. Results again showed a largely linear conformity effect that varied little with the variables analyzed. PMID:24950212
Display aids for remote control of untethered undersea vehicles
NASA Technical Reports Server (NTRS)
Verplank, W. L.
1978-01-01
A predictor display superimposed on slow-scan video or sonar data is proposed as a method to allow better remote manual control of an untethered submersible. Simulation experiments show good control under circumstances which otherwise make control practically impossible.
Cao, Xuan; Lau, Christian; Liu, Yihang; Wu, Fanqi; Gui, Hui; Liu, Qingzhou; Ma, Yuqiang; Wan, Haochuan; Amer, Moh R; Zhou, Chongwu
2016-11-22
Semiconducting single-wall carbon nanotubes are ideal semiconductors for printed electronics due to their advantageous electrical and mechanical properties, intrinsic printability in solution, and desirable stability in air. However, fully printed, large-area, high-performance, and flexible carbon nanotube active-matrix backplanes are still difficult to realize for future displays and sensing applications. Here, we report fully screen-printed active-matrix electrochromic displays employing carbon nanotube thin-film transistors. Our fully printed backplane shows high electrical performance with mobility of 3.92 ± 1.08 cm 2 V -1 s -1 , on-off current ratio I on /I off ∼ 10 4 , and good uniformity. The printed backplane was then monolithically integrated with an array of printed electrochromic pixels, resulting in an entirely screen-printed active-matrix electrochromic display (AMECD) with good switching characteristics, facile manufacturing, and long-term stability. Overall, our fully screen-printed AMECD is promising for the mass production of large-area and low-cost flexible displays for applications such as disposable tags, medical electronics, and smart home appliances.
NASA Technical Reports Server (NTRS)
Liao, Min-Ju; Johnson, Walter W.
2004-01-01
The present study investigated the effects of droplines on target acquisition performance on a 3-D perspective display in which participants were required to move a cursor into a target cube as quickly as possible. Participants' performance and coordination strategies were characterized using both Fitts' law and acquisition patterns of the 3 viewer-centered target display dimensions (azimuth, elevation, and range). Participants' movement trajectories were recorded and used to determine movement times for acquisitions of the entire target and of each of its display dimensions. The goodness of fit of the data to a modified Fitts function varied widely among participants, and the presence of droplines did not have observable impacts on the goodness of fit. However, droplines helped participants navigate via straighter paths and particularly benefited range dimension acquisition. A general preference for visually overlapping the target with the cursor prior to capturing the target was found. Potential applications of this research include the design of interactive 3-D perspective displays in which fast and accurate selection and manipulation of content residing at multiple ranges may be a challenge.
Lang, Qiaolin; Wang, Fei; Yin, Long; Liu, Mingjun; Petrenko, Valery A; Liu, Aihua
2014-03-04
Probes against targets can be selected from the landscape phage library f8/8, displaying random octapeptides on the pVIII coat protein of the phage fd-tet and demonstrating many excellent features including multivalency, stability, and high structural homogeneity. Prostate-specific antigen (PSA) is usually determined by immunoassay, by which antibodies are frequently used as the specific probes. Herein we found that more advanced probes against free prostate-specific antigen (f-PSA) can be screened from the landscape phage library. Four phage monoclones were selected and identified by the specificity array. One phage clone displaying the fusion peptide ERNSVSPS showed good specificity and affinity to f-PSA and was used as a PSA capture probe in a sandwich enzyme-linked immunosorbent assay (ELISA) array. An anti-human PSA monoclonal antibody (anti-PSA mAb) was used to recognize the captured antigen, followed by horseradish peroxidase-conjugated antibody (HRP-IgG) and o-phenylenediamine, which were successively added to develop plate color. The ELISA conditions such as effect of blocking agent, coating buffer pH, phage concentration, antigen incubation time, and anti-PSA mAb dilution for phage ELISA were optimized. On the basis of the optimal phage ELISA conditions, the absorbance taken at 492 nm on a microplate reader was linear with f-PSA concentration within 0.825-165 ng/mL with a low limit of detection of 0.16 ng/mL. Thus, the landscape phage is an attractive biomolecular probe in bioanalysis.
Sagasti, Ariane; Bouropoulos, Nikolaos; Kouzoudis, Dimitris; Panagiotopoulos, Apostolos; Topoglidis, Emmanuel; Gutiérrez, Jon
2017-01-01
In the present work, a nanostructured ZnO layer was synthesized onto a Metglas magnetoelastic ribbon to immobilize hemoglobin (Hb) on it and study the Hb’s electrochemical behavior towards hydrogen peroxide. Hb oxidation by H2O2 was monitored simultaneously by two different techniques: Cyclic Voltammetry (CV) and Magnetoelastic Resonance (MR). The Metglas/ZnO/Hb system was simultaneously used as a working electrode for the CV scans and as a magnetoelastic sensor excited by external coils, which drive it to resonance and interrogate it. The ZnO nanoparticles for the ZnO layer were grown hydrothermally and fully characterized by X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) and photoluminescence (PL). Additionally, the ZnO layer’s elastic modulus was measured using a new method, which makes use of the Metglas substrate. For the detection experiments, the electrochemical cell was performed with a glass vial, where the three electrodes (working, counter and reference) were immersed into PBS (Phosphate Buffer Solution) solution and small H2O2 drops were added, one at a time. CV scans were taken every 30 s and 5 min after the addition of each drop and meanwhile a magnetoelastic measurement was taken by the external coils. The CV plots reveal direct electrochemical behavior of Hb and display good electrocatalytic response to the reduction of H2O2. The measured catalysis currents increase linearly with the H2O2 concentration in a wide range of 25–350 μM with a correlation coefficient 0.99. The detection limit is 25–50 μM. Moreover, the Metglas/ZnO/Hb electrode displays rapid response (30 s) to H2O2, and exhibits good stability and reproducibility of the measurements. On the other hand, the magnetoelastic measurements show a small linear mass increase versus the H2O2 concentration with a slope of 152 ng/μM, which is probably due to H2O2 adsorption in ZnO during the electrochemical reaction. No such effects were detected during the control experiment when only PBS solution was present for a long time. PMID:28773209
Use of Linear Perspective Scene Cues in a Simulated Height Regulation Task
NASA Technical Reports Server (NTRS)
Levison, W. H.; Warren, R.
1984-01-01
As part of a long-term effort to quantify the effects of visual scene cuing and non-visual motion cuing in flight simulators, an experimental study of the pilot's use of linear perspective cues in a simulated height-regulation task was conducted. Six test subjects performed a fixed-base tracking task with a visual display consisting of a simulated horizon and a perspective view of a straight, infinitely-long roadway of constant width. Experimental parameters were (1) the central angle formed by the roadway perspective and (2) the display gain. The subject controlled only the pitch/height axis; airspeed, bank angle, and lateral track were fixed in the simulation. The average RMS height error score for the least effective display configuration was about 25% greater than the score for the most effective configuration. Overall, larger and more highly significant effects were observed for the pitch and control scores. Model analysis was performed with the optimal control pilot model to characterize the pilot's use of visual scene cues, with the goal of obtaining a consistent set of independent model parameters to account for display effects.
Clinical evaluation of a 2K x 2K workstation for primary diagnosis in pediatric radiology
NASA Astrophysics Data System (ADS)
Razavi, Mahmood; Sayre, James W.; Simons, Margaret A.; Hamedaninia, Azar; Boechat, Maria I.; Hall, Theodore R.; Kangarloo, Hooshang; Taira, Ricky K.; Chuang, Keh-Shih; Kashifian, Payam
1991-07-01
Preliminary results of a large-scale ROC study evaluating the diagnostic performance of digital hardcopy film and 2K X 2K softcopy display for pediatric chest radiographs are presented. The pediatric disease categories studied were pneumothorax, linear atelectasis, air bronchograms, and interstitial disease. Digital images were obtained directly from a computed radiography system. Results from the readings of 239 chest radiographs by 4 radiologists show no significant difference between viewing images on film and softcopy display for the disease categories pneumothorax and air bronchograms. A slight performance edge for softcopy was seen for the disease categories of interstitial disease and linear atelectasis.
Human factors optimization of virtual environment attributes for a space telerobotic control station
NASA Astrophysics Data System (ADS)
Lane, Jason Corde
2000-10-01
Remote control of underwater vehicles and other robotic systems has, up until now, proved to be a challenging task for the human operator. With technology advancements in computers and displays, computer interfaces can be used to alleviate the workload on the operator. This research introduces the concept of a commanded display, which is a graphical simulation that shows the commands sent to the actual system in real-time. The primary goal of this research was to show a commanded display as an alternative to the traditional predictive display for reducing the effects of time delay. Several experiments were used to investigate how subjects compensated for time delay under a variety of conditions while controlling a 7-degree of freedom robotic manipulator. Results indicate that time delay increased completion time linearly; this linear relationship occurred even at different manipulator speeds, varying levels of error, and when using a commanded display. The commanded display alleviated the majority of time delay effects, up to 91% reduction. The commanded display also facilitated more accurate control, reducing the number of inadvertent impacts to the task worksite, even when compared to no time delay. Even with a moderate error between the commanded and actual displays, the commanded display was still a useful tool for mitigating time delay. The way subjects controlled the manipulator with the input device was tracked and their control strategies were extracted. A correlation between the subjects' use of the input device and their task completion time was determined. The importance of stereo vision and head tracking was examined and shown to improve a subject's depth perception within a virtual environment. Reports of simulator sickness induced by display equipment, including a head mounted display and LCD shutter glasses, were compared. The results of the above testing were used to develop an effective virtual environment control station to control a multi-arm robot.
General radiographic attributes of optically stimulated luminescence dosimeters: A basic insight
NASA Astrophysics Data System (ADS)
Musa, Y.; Hashim, S.; Ghoshal, S. K.; Bradley, D. A.; Ahmad, N. E.; Karim, M. K. A.; Hashim, A.; Kadir, A. B. A.
2018-06-01
We report the ubiquitous radiographic characteristics of optically stimulated luminescence dosimeters (OSLD) so called nanoDot OSLDs (Landauer Inc., Glendwood, IL). The X-ray irradiations were performed in free air ambiance to inspect the repeatability, the reproducibility, the signal depletion, the element correction factors (ECFs), the dose response and the energy dependence. Repeatability of multiple readouts after single irradiation to 10 mGy revealed a coefficient of variation below 3%, while the reproducibility in repeated irradiation-readout-annealing cycles was above 2%. The OSL signal depletion for three nanoDots with simultaneous irradiation to 20 mGy and sequential readouts of 25 times displayed a consistent signal reduction ≈0.5% per readout with R2 values over 0.98. ECFs for individual OSLDs were varied from 0.97 to 1.03. In the entire dose range under 80 kV, a good linearity with an R2 exceeding 0.99 was achieved. Besides, the percentage difference between OSLD and ion-chamber dose was less than 5%, which was superior to TLD. The X-ray photon irradiated energy response factors (between 0.76 and 1.12) in the range of 40-150 kV (26.1-61.2 keV) exhibited significant energy dependence. Indeed, the nanoDot OSLDs disclosed good repeatability, reproducibility and linearity. The OSLDs measured doses were closer to ion-chamber doses than that of TLD. It can be further improved up to ≈3% by applying the individual dosimeter ECF. On top, the energy dependent uncertainties can be minimized using the energy correction factors. It is established that the studied nanoDot OSLDs are prospective for measuring entrance dose in general radiographic practices.
Li, Jianlin; Han, Tao; Wei, Nannan; Du, Jiangyan; Zhao, Xiangwei
2009-12-15
Gold nanoparticles have been introduced into the wall framework of titanium dioxide photonic crystals by the colloidal crystal template technique. The three-dimensionally ordered macroporous gold-nanoparticle-doped titanium dioxide (3DOM GTD) film was modified on the indium-tin oxide (ITO) electrode surface and used for the hydrogen peroxide biosensor. The direct electron transfer and electrocatalysis of horseradish peroxidase (HRP) immobilized on this film have been investigated. The 3DOM GTD film could provide a good microenvironment for retaining the biological bioactivity, large internal area, and superior conductivity. The HRP/3DOM GTD/ITO electrode exhibited two couples of redox peaks corresponding to the HRP intercalated in the mesopores and adsorbed on the external surface of the film with the formal potential of -0.19 and -0.52V in 0.1M PBS (pH 7.4), respectively. The HRP intercalated in the mesopores showed a surface-controlled process with a single proton transfer. The direct electron transfer between the adsorbed HRP and the electrode is achieved without the aid of an electron mediator. The H(2)O(2) biosensor displayed a rapid eletrocatalytic response (less than 3s), a wide linear range from 0.5 microM to 1.4mM with a detection limit of 0.2 microM, high sensitivity (179.9 microAmM(-1)), good stability and reproducibility. Compared with the free-Au doped titanium dioxide photonic crystals modified electrode, the GTD modified electrode could greatly enhance the response current signal, linear detection range and higher sensitivity. The 3DOM GTD provided a new matrix for protein immobilization and direct transfer study and opened a way for low conductivity electrode biosensor.
Review: Game theory of public goods in one-shot social dilemmas without assortment.
Archetti, Marco; Scheuring, István
2012-04-21
We review the theory of public goods in biology. In the N-person prisoner's dilemma, where the public good is a linear function of the individual contributions, cooperation requires some form of assortment, for example due to kin discrimination, population viscosity or repeated interactions. In most social species ranging from bacteria to humans, however, public goods are usually a non-linear function of the contributions, which makes cooperation possible without assortment. More specifically, a polymorphic state can be stable in which cooperators and non-cooperators coexist. The existence of mixed equilibria in public goods games is a fundamental result in the study of cooperation that has been overlooked so far, because of the disproportionate attention given to the two- and N-person prisoner's dilemma. Methods and results from games with pairwise interactions or linear benefits cannot, in general, be extended to the analysis of public goods. Game theory helps explain the production of public goods in one-shot, N-person interactions without assortment, it leads to predictions that can be easily tested and allows a prescriptive approach to cooperation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zhou, Tuantuan; Gao, Wanlin; Wang, Qiang; Umar, Ahmad
2018-05-01
Herein, we report the facile synthesis of high-aspect ratio perforated Co3O4 nanowires derived from cobalt-carbonate-hydroxide (Co(CO3)0.5(OH) 0.11H2O) nanowires. The Co(CO3)0.5(OH) 0.11H2O nanowires were synthesized by simple hydrothermal process at 120 °C while annealing of such nanowires at 400 °C leads the formation of perforated Co3O4 nanowires. The prepared nanowires were characterized by several techniques which confirmed the high aspect ratio and well-crystallinity for the synthesized nanowires. For application point of view, the prepared perforated Co3O4 nanowires were used as efficient electrode material to fabricate highly sensitive and selective hydrazine chemical sensor. The electrochemical impedance spectroscopy (EIS) technique was employed to confirm the successful modification of the electrode. The key parameters of chemical sensor, such as detection limit, sensitivity, and linear range, have been systematically explored. The fabricated hydrazine sensor displayed a rather low detection limit of 4.52 μM (S/N = 3), a good sensitivity of 25.70 μA · mM-1, and a wide linear range of 16.97-358.34 μM.
Performance optimization in electric field gradient focusing.
Sun, Xuefei; Farnsworth, Paul B; Tolley, H Dennis; Warnick, Karl F; Woolley, Adam T; Lee, Milton L
2009-01-02
Electric field gradient focusing (EFGF) is a technique used to simultaneously separate and concentrate biomacromolecules, such as proteins, based on the opposing forces of an electric field gradient and a hydrodynamic flow. Recently, we reported EFGF devices fabricated completely from copolymers functionalized with poly(ethylene glycol), which display excellent resistance to protein adsorption. However, the previous devices did not provide the predicted linear electric field gradient and stable current. To improve performance, Tris-HCl buffer that was previously doped in the hydrogel was replaced with a phosphate buffer containing a salt (i.e., potassium chloride, KCl) with high mobility ions. The new devices exhibited stable current, good reproducibility, and a linear electric field distribution in agreement with the shaped gradient region design due to improved ion transport in the hydrogel. The field gradient was calculated based on theory to be approximately 5.76 V/cm(2) for R-phycoerythrin when the applied voltage was 500 V. The effect of EFGF separation channel dimensions was also investigated; a narrower focused band was achieved in a smaller diameter channel. The relationship between the bandwidth and channel diameter is consistent with theory. Three model proteins were resolved in an EFGF channel of this design. The improved device demonstrated 14,000-fold concentration of a protein sample (from 2 ng/mL to 27 microg/mL).
Dasgupta, Queeny; Movva, Sahitya; Chatterjee, Kaushik; Madras, Giridhar
2017-08-07
This work reports the synthesis of a novel, aspirin-loaded, linear poly (anhydride ester) and provides mechanistic insights into the release of aspirin from this polymer for anti-inflammatory activity. As compared to conventional drug delivery systems that rely on diffusion based release, incorporation of bioactives in the polymer backbone is challenging and high loading is difficult to achieve. In the present study, we exploit the pentafunctional sugar alcohol (xylitol) to provide sites for drug (aspirin) attachment at its non-terminal OH groups. The terminal OH groups are polymerized with a diacid anhydride. The hydrolysis of the anhydride and ester bonds under physiological conditions release aspirin from the matrix. The resulting poly(anhydride ester) has high drug loading (53%) and displays controlled release kinetics of aspirin. The polymer releases 8.5 % and 20%, of the loaded drug in one and four weeks, respectively and has a release rate constant of 0.0035h -0.61 . The release rate is suitable for its use as an anti-inflammatory agent without being cytotoxic. The polymer exhibits good cytocompatibility and anti-inflammatory properties and may find applications as injectable or as an implantable bioactive material. The physical insights into the release mechanism can provide development of other drug loaded polymers. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimum display luminance depends on white luminance under various ambient illuminance conditions
NASA Astrophysics Data System (ADS)
Kim, Minkoo; Jeon, Dong-Hwan; Kim, Jeong-Sik; Yu, Byung-Chang; Park, YungKyung; Lee, Seung-Woo
2018-02-01
This paper reports display luminance levels for good visibility under nine ambient illuminance conditions (50, 100, 200, 500, 1000, 2000, 5000, 10,000, and 20,000 lx) for a given white luminance level, chosen from five candidates (100, 200, 500, 1000, and 2000 cd / m2), through a psychophysical experiment. This work reveals that the luminance levels for good visibility increase as the maximum white luminance of the display increases. The white luminance dependency of display luminance is caused by the fact that the human visual system adapts to the maximum white luminance and evaluates the brightness of the display based on it. Based on the experimental results, an appropriate luminance zone under various illuminance conditions is proposed. The appropriate luminance zone varies with the maximum white luminance of the displays. This may be understood to mean that there is no absolute luminance level under a given lighting condition. To solve this issue, a new method is proposed to determine optimum luminance levels by considering both visibility and power consumption. By the proposed method, it is reported that the optimum maximum luminance lies between 200 and 500 cd / m2 for indoor use (below 500 lx). These results were verified by young adults with normal vision.
Wang, ShuLing; Xu, Hui
2016-12-01
An inorganic-organic hybrid nanocomposite (zinc oxide/polypyrrole) that represents a novel kind of coating for in-tube solid-phase microextraction is reported. The composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless-steel tube. Based on the coated tube, a novel online in-tube solid-phase microextraction with liquid chromatography and mass spectrometry method was developed and applied for the extraction of three monohydroxy polycyclic aromatic hydrocarbons in human urine. The coating displayed good extraction ability toward monohydroxy polycyclic aromatic hydrocarbons. In addition, long lifespan, excellent stability, and good compression resistance were also obtained for the coating. The experimental conditions affecting the extraction were optimized systematically. Under the optimal conditions, the limits of detection and quantification were in the range of 0.039-0.050 and 0.130-0.167 ng/mL, respectively. Good linearity (0.2-100 ng/mL) was obtained with correlation coefficients larger than 0.9967. The repeatability, expressed as relative standard deviation, ranged between 2.5% and 9.4%. The method offered the advantage of process simplicity, rapidity, automation, and sensitivity in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities of Hubei province. An acceptable recovery of monohydroxy polycyclic aromatic hydrocarbons (64-122%) represented the additional attractive features of the method in real urine analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Joiner, Wilsaan M; Ajayi, Obafunso; Sing, Gary C; Smith, Maurice A
2011-01-01
The ability to generalize learned motor actions to new contexts is a key feature of the motor system. For example, the ability to ride a bicycle or swing a racket is often first developed at lower speeds and later applied to faster velocities. A number of previous studies have examined the generalization of motor adaptation across movement directions and found that the learned adaptation decays in a pattern consistent with the existence of motor primitives that display narrow Gaussian tuning. However, few studies have examined the generalization of motor adaptation across movement speeds. Following adaptation to linear velocity-dependent dynamics during point-to-point reaching arm movements at one speed, we tested the ability of subjects to transfer this adaptation to short-duration higher-speed movements aimed at the same target. We found near-perfect linear extrapolation of the trained adaptation with respect to both the magnitude and the time course of the velocity profiles associated with the high-speed movements: a 69% increase in movement speed corresponded to a 74% extrapolation of the trained adaptation. The close match between the increase in movement speed and the corresponding increase in adaptation beyond what was trained indicates linear hypergeneralization. Computational modeling shows that this pattern of linear hypergeneralization across movement speeds is not compatible with previous models of adaptation in which motor primitives display isotropic Gaussian tuning of motor output around their preferred velocities. Instead, we show that this generalization pattern indicates that the primitives involved in the adaptation to viscous dynamics display anisotropic tuning in velocity space and encode the gain between motor output and motion state rather than motor output itself.
Reflective and transflective liquid crystal displays
NASA Astrophysics Data System (ADS)
Zhou, Fushan
Recently transflective liquid crystal displays (LCD) received a lot of attention. A transflective display has a transmissive mode and a reflective mode. It combines the high contrast, high brightness of the transmissive mode with energy-saving of reflective mode and has good performance in various illumination conditions. However, state-of-the-art transflective displays have problems such as different electro-optical properties, difficulty in compatibility and optimization of both modes, low efficiency of light utilization, and complexity in structure. This dissertation focuses on finding new designs of transflective displays that address those problems. One way to do this is to study film compensation of LCD. We first studied film compensation of bistable twisted nematic (BTN) LCD. Starting form the reduced (3x3) Mueller matrices, we derived and simplified the conditions that film compensated BTN can be optimized. Based on these relations, electro-optical properties of some particular configurations, and designs of transflective BTN with high brightness and contrast were given. To confirm and get a better understanding of the results, we use the Poincare sphere to analyze film compensated BTN. The key to this approach is the existence of "fixed points". Compared with the matrix approach, this approach is more simple, elegant, and efficient. We then generalized the Poincare sphere approach to a universal approach of LCD. We applied the universal approach to film compensation of ECB and IPS, and the design of achromatic birefringent filters. We also give two more new designs of transflective displays. In the first design, a dichroic mirror is used to split the visible spectrum into two parts used in transmissive and reflective modes, respectively. Both modes can be optimized. It has a simple structure and good light utilization. A design for a full-color transflective display with good performance is also given. In the second design, each pixel is divided into two sub-pixels, a transmissive one and a reflective one. By using polymer stabilization, the birefringence of the transmissive sub-pixels is twice that of the reflective ones. The display has single cell gap, low driving voltage, fast response, high contrast and brightness, and the transmissive and reflective modes are synchronized.
Mishra, Rupesh K; Martín, Aida; Nakagawa, Tatsuo; Barfidokht, Abbas; Lu, Xialong; Sempionatto, Juliane R; Lyu, Kay Mengjia; Karajic, Aleksandar; Musameh, Mustafa M; Kyratzis, Ilias L; Wang, Joseph
2018-03-15
Flexible epidermal tattoo and textile-based electrochemical biosensors have been developed for vapor-phase detection of organophosphorus (OP) nerve agents. These new wearable sensors, based on stretchable organophosphorus hydrolase (OPH) enzyme electrodes, are coupled with a fully integrated conformal flexible electronic interface that offers rapid and selective square-wave voltammetric detection of OP vapor threats and wireless data transmission to a mobile device. The epidermal tattoo and textile sensors display a good reproducibility (with RSD of 2.5% and 4.2%, respectively), along with good discrimination against potential interferences and linearity over the 90-300mg/L range, with a sensitivity of 10.7µA∙cm 3 ∙mg -1 (R 2 = 0.983) and detection limit of 12mg/L in terms of OP air density. Stress-enduring inks, used for printing the electrode transducers, ensure resilience against mechanical deformations associated with textile and skin-based on-body sensing operations. Theoretical simulations are used to estimate the OP air density over the sensor surface. These fully integrated wearable wireless tattoo and textile-based nerve-agent vapor biosensor systems offer considerable promise for rapid warning regarding personal exposure to OP nerve-agent vapors in variety of decentralized security applications. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Panda, Bishnu P.; Mohanty, Smita; Nayak, Sanjay K.
2014-09-01
This research aims to study the effect of accelerated weathering conditions on the photodegradation characteristics for fibrillar silicate clay-filled Polypropylene (PP) nanocomposites in the presence of metallocene linear low density polyethylene (m-LLDPE). Silane-treated attapulgite (ATP) clay along with ethylene octene elastomer-grafted maleic anhydride (POE-g-MAH) was used to compatibilize both blend and nanocomposite system. The result showed that developed PP/m-LLDPE nanocomposites displayed good UV resistance with little change in retained stress-at-break and elongation-at-break values. Balanced loss of toughness values noted maintaining higher fracture toughness values for nanocomposites containing 5 phr ATP clay. Infrared analysis was used to detect progress of degradation followed by change in carbonyl index revealed predominated chain scission in late irradiation, while crosslinking was dominant for initial irradiation period. An increase in crystallinity during UV exposure (chemi-crystallization) was detected with exposure time for all compositions and virtually independent of initial structure of the polymer. The highest value of crystallization observed for PP and the lowest one for nanocomposites containing 5 phr of ATP clay revealed good oxidation stability. Surface morphology revealed induced degradation throughout cross-section of PP, while severity of the surface degradation was significantly reduced for developed nanocomposites.
Electrically Tilted Liquid Crystal Display Mode for High Speed Operation
NASA Astrophysics Data System (ADS)
Gwag, Jin Seog; Kim, Jae Chang; Yoon, Tae-Hoon
2006-09-01
To develop liquid crystal displays suitable for moving picture, a liquid crystal display mode having an electrically tilted phase is proposed. This is realized by initially having a tilted liquid crystal with low bias voltage. We found that its measured response time is in good agreement with numerical calculation obtained using the Erickson-Leslie equation. The falling times were smaller than 10 ms with conventional driving and 6 ms with overdriving.
DOT National Transportation Integrated Search
1996-10-01
Certain air traffic control(ATC) centers experienced a series of major outages, : some of which were caused by the Display Channel Complex or DCC-a mainframe : computer system that processes radar and other data into displayable images on : controlle...
NASA Technical Reports Server (NTRS)
Correia, Manning J.; Luke, Brian L.; McGrath, Braden J.; Clark, John B.; Rupert, Angus H.
1996-01-01
While considerable attention has been given to visual-vestibular interaction (VVI) during angular motion of the head as might occur during an aircraft spin, much less attention has been given to VVI during linear motion of the head. Such interaction might occur, for example, while viewing a stationary or moving display during vertical take-off and landing operations Research into linear VVI, particularly during prolonged periods of linear acceleration, has been hampered by the unavailability of a programmable translator capable of large excursions We collaborated with Otis Elevator Co. and used their research tower and elevator, whose motion could be digitally programmed, to vertically translate human subjects over a distance of 92.3 meters with a peak linear acceleration of 2 meters/sec(exp 2) During pulsatile or sinusoidal translation, the subjects viewed moving stripes (optokinetic stimulus) or a fixed point source (light emitting diode, led, display), respectively and it was generally found that. The direction of linear acceleration relative to the cardinal head axes and the direction of the slow component of optokinetic nystagmus (OKN) determined the extent of VVI during concomitant stripe motion and linear acceleration. Acceleration along the z head axis (A(sub z)) produced the largest VVI, particularly when the slow component of OKN was in the same direction as eye movements produced by the linear acceleration and Eye movements produced by linear acceleration are suppressed by viewing a fixed target at frequencies below 10 Hz But, above this frequency the suppression produced by VVI is removed. Finally, as demonstrated in non-human primates, vergence of the eyes appears to modulate the vertical eye movement response to linear acceleration in humans.
Display nonlinearity in digital image processing for visual communications
NASA Astrophysics Data System (ADS)
Peli, Eli
1992-11-01
The luminance emitted from a cathode ray tube (CRT) display is a nonlinear function (the gamma function) of the input video signal voltage. In most analog video systems, compensation for this nonlinear transfer function is implemented in the camera amplifiers. When CRT displays are used to present psychophysical stimuli in vision research, the specific display nonlinearity usually is measured and accounted for to ensure that the luminance of each pixel in the synthetic image property represents the intended value. However, when using digital image processing, the linear analog-to-digital converters store a digital image that is nonlinearly related to the displayed or recorded image. The effect of this nonlinear transformation on a variety of image-processing applications used in visual communications is described.
Display nonlinearity in digital image processing for visual communications
NASA Astrophysics Data System (ADS)
Peli, Eli
1991-11-01
The luminance emitted from a cathode ray tube, (CRT) display is a nonlinear function (the gamma function) of the input video signal voltage. In most analog video systems, compensation for this nonlinear transfer function is implemented in the camera amplifiers. When CRT displays are used to present psychophysical stimuli in vision research, the specific display nonlinearity usually is measured and accounted for to ensure that the luminance of each pixel in the synthetic image properly represents the intended value. However, when using digital image processing, the linear analog-to-digital converters store a digital image that is nonlinearly related to the displayed or recorded image. This paper describes the effect of this nonlinear transformation on a variety of image-processing applications used in visual communications.
TIME CALIBRATED OSCILLOSCOPE SWEEP
Owren, H.M.; Johnson, B.M.; Smith, V.L.
1958-04-22
The time calibrator of an electric signal displayed on an oscilloscope is described. In contrast to the conventional technique of using time-calibrated divisions on the face of the oscilloscope, this invention provides means for directly superimposing equal time spaced markers upon a signal displayed upon an oscilloscope. More explicitly, the present invention includes generally a generator for developing a linear saw-tooth voltage and a circuit for combining a high-frequency sinusoidal voltage of a suitable amplitude and frequency with the saw-tooth voltage to produce a resultant sweep deflection voltage having a wave shape which is substantially linear with respect to time between equal time spaced incremental plateau regions occurring once each cycle of the sinusoidal voltage. The foregoing sweep voltage when applied to the horizontal deflection plates in combination with a signal to be observed applied to the vertical deflection plates of a cathode ray oscilloscope produces an image on the viewing screen which is essentially a display of the signal to be observed with respect to time. Intensified spots, or certain other conspicuous indications corresponding to the equal time spaced plateau regions of said sweep voltage, appear superimposed upon said displayed signal, which indications are therefore suitable for direct time calibration purposes.
Visual to Parametric Interaction (V2PI)
Maiti, Dipayan; Endert, Alex; North, Chris
2013-01-01
Typical data visualizations result from linear pipelines that start by characterizing data using a model or algorithm to reduce the dimension and summarize structure, and end by displaying the data in a reduced dimensional form. Sensemaking may take place at the end of the pipeline when users have an opportunity to observe, digest, and internalize any information displayed. However, some visualizations mask meaningful data structures when model or algorithm constraints (e.g., parameter specifications) contradict information in the data. Yet, due to the linearity of the pipeline, users do not have a natural means to adjust the displays. In this paper, we present a framework for creating dynamic data displays that rely on both mechanistic data summaries and expert judgement. The key is that we develop both the theory and methods of a new human-data interaction to which we refer as “ Visual to Parametric Interaction” (V2PI). With V2PI, the pipeline becomes bi-directional in that users are embedded in the pipeline; users learn from visualizations and the visualizations adjust to expert judgement. We demonstrate the utility of V2PI and a bi-directional pipeline with two examples. PMID:23555552
Performance characterization of a single bi-axial scanning MEMS mirror-based head-worn display
NASA Astrophysics Data System (ADS)
Liang, Minhua
2002-06-01
The NomadTM Personal Display System is a head-worn display (HWD) with a see-through, high-resolution, high-luminance display capability. It is based on a single bi-axial scanning MEMS mirror. In the Nomad HWD system, a red laser diode emits a beam of light that is scanned bi-axially by a single MEMS mirror. A diffractive beam diffuser and an ocular expand the beam to form a 12mm exit pupil for comfortable viewing. The Nomad display has an SVGA (800x600) resolution, 60Hz frame rate, 23-degree horizontal field of view (FOV) and 3:4 vertical to horizontal aspect ratio, a luminance of 800~900 foot-Lamberts, see-through capability, 30mm eye-relief distance, and 1-foot to infinity focusing adjustment. We have characterized the performance parameters, such as field of view, distortion, contrast ratio (4x4 black and white checker board), modulation depth, exit pupil size, eye relief distance, maximum luminance, dynamic range ratio (full-on-to-full-off ratio), dimming ratio, and luminance uniformity at image plane. The Class-1 eye-safety requirements per IEC 60825-1 Amendment 2 (CDRH Laser Notice No. 50) are analyzed and verified by experiments. The paper describes all of the testing methods and set-ups as well as the representative test results. The test results demonstrate that the Nomad display is an eye-safe display product with good image quality and good user ergonomics.
75 FR 38714 - Safety Zone; Macy's Fourth of July Fireworks Display, Hudson River, New York, NY
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-06
... prior notice and opportunity to comment when the agency for good cause finds that those procedures are... finds that good cause exists for not publishing a notice of proposed rulemaking (NPRM) with respect to... Guard finds that good cause exists for making this rule effective less than 30 days after publication in...
NASA Astrophysics Data System (ADS)
Cvetkovic, Sascha D.; Schirris, Johan; de With, Peter H. N.
2009-01-01
For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are unacceptable. Compression of the dynamic range is therefore a compulsory part of any high-end video processing chain because standard monitors are inherently Low- Dynamic Range (LDR) devices with maximally two orders of display dynamic range. In real-time camera processing, many complex scenes are improved with local contrast enhancements, bringing details to the best possible visibility. In this paper, we show how a multi-scale high-frequency enhancement scheme, in which gain is a non-linear function of the detail energy, can be used for the dynamic range compression of HDR real-time video camera signals. We also show the connection of our enhancement scheme to the processing way of the Human Visual System (HVS). Our algorithm simultaneously controls perceived sharpness, ringing ("halo") artifacts (contrast) and noise, resulting in a good balance between visibility of details and non-disturbance of artifacts. The overall quality enhancement, suitable for both HDR and LDR scenes, is based on a careful selection of the filter types for the multi-band decomposition and a detailed analysis of the signal per frequency band.
A Linearized Model for Flicker and Contrast Thresholds at Various Retinal Illuminances
NASA Technical Reports Server (NTRS)
Ahumada, Albert; Watson, Andrew
2015-01-01
We previously proposed a flicker visibility metric for bright displays, based on psychophysical data collected at a high mean luminance. Here we extend the metric to other mean luminances. This extension relies on a linear relation between log sensitivity and critical fusion frequency, and a linear relation between critical fusion frequency and log retina lilluminance. Consistent with our previous metric, the extended flicker visibility metric is measured in just-noticeable differences (JNDs).
Illuminant-adaptive color reproduction for mobile display
NASA Astrophysics Data System (ADS)
Kim, Jong-Man; Park, Kee-Hyon; Kwon, Oh-Seol; Cho, Yang-Ho; Ha, Yeong-Ho
2006-01-01
This paper proposes an illuminant-adaptive reproduction method using light adaptation and flare conditions for a mobile display. Mobile displays, such as PDAs and cellular phones, are viewed under various lighting conditions. In particular, images displayed in daylight are perceived as quite dark due to the light adaptation of the human visual system, as the luminance of a mobile display is considerably lower than that of an outdoor environment. In addition, flare phenomena decrease the color gamut of a mobile display by increasing the luminance of dark areas and de-saturating the chroma. Therefore, this paper presents an enhancement method composed of lightness enhancement and chroma compensation. First, the ambient light intensity is measured using a lux-sensor, then the flare is calculated based on the reflection ratio of the display device and the ambient light intensity. The relative cone response is nonlinear to the input luminance. This is also changed by the ambient light intensity. Thus, to improve the perceived image, the displayed luminance is enhanced by lightness linearization. In this paper, the image's luminance is transformed by linearization of the response to the input luminance according to the ambient light intensity. Next, the displayed image is compensated according to the physically reduced chroma, resulting from flare phenomena. The reduced chroma value is calculated according to the flare for each intensity. The chroma compensation method to maintain the original image's chroma is applied differently for each hue plane, as the flare affects each hue plane differently. At this time, the enhanced chroma also considers the gamut boundary. Based on experimental observations, the outer luminance-intensity generally ranges from 1,000 lux to 30,000 lux. Thus, in the case of an outdoor environment, i.e. greater than 1,000 lux, this study presents a color reproduction method based on an inverse cone response curve and flare condition. Consequently, the proposed algorithm improves the quality of the perceived image adaptive to an outdoor environment.
Reduced-thickness backlighter for autostereoscopic display and display using the backlighter
NASA Technical Reports Server (NTRS)
Eichenlaub, Jesse B (Inventor); Gruhlke, Russell W (Inventor)
1999-01-01
A reduced-thickness backlighter for an autostereoscopic display is disclosed having a lightguide and at least one light source parallel to an edge of the lightguide so as to be substantially coplanar with the lightguide. The lightguide is provided with a first surface which has a plurality of reflective linear regions, such as elongated grooves or glossy lines, parallel to the illuminated edge of the lightguide. Preferably the lightguide further has a second surface which has a plurality of lenticular lenses for reimaging the reflected light from the linear regions into a series of thin vertical lines outside the guide. Because of the reduced thickness of the backlighter system, autostereoscopic viewing is enabled in applications requiring thin backlighter systems. In addition to taking up less space, the reduced-thickness backlighter uses less lamps and less power. For accommodating 2-D applications, a 2-D diffuser plate or a 2-D lightguide parallel to the 3-D backlighter is disclosed for switching back and forth between 3-D viewing and 2-D viewing.
Peden, Robert G; Mercer, Rachel; Tatham, Andrew J
2016-10-01
To investigate whether 'surgeon's eye view' videos provided via head-mounted displays can improve skill acquisition and satisfaction in basic surgical training compared with conventional wet-lab teaching. A prospective randomised study of 14 medical students with no prior suturing experience, randomised to 3 groups: 1) conventional teaching; 2) head-mounted display-assisted teaching and 3) head-mounted display self-learning. All were instructed in interrupted suturing followed by 15 minutes' practice. Head-mounted displays provided a 'surgeon's eye view' video demonstrating the technique, available during practice. Subsequently students undertook a practical assessment, where suturing was videoed and graded by masked assessors using a 10-point surgical skill score (1 = very poor technique, 10 = very good technique). Students completed a questionnaire assessing confidence and satisfaction. Suturing ability after teaching was similar between groups (P = 0.229, Kruskal-Wallis test). Median surgical skill scores were 7.5 (range 6-10), 6 (range 3-8) and 7 (range 1-7) following head-mounted display-assisted teaching, conventional teaching, and head-mounted display self-learning respectively. There was good agreement between graders regarding surgical skill scores (rho.c = 0.599, r = 0.603), and no difference in number of sutures placed between groups (P = 0.120). The head-mounted display-assisted teaching group reported greater enjoyment than those attending conventional teaching (P = 0.033). Head-mounted display self-learning was regarded as least useful (7.4 vs 9.0 for conventional teaching, P = 0.021), but more enjoyable than conventional teaching (9.6 vs 8.0, P = 0.050). Teaching augmented with head-mounted displays was significantly more enjoyable than conventional teaching. Students undertaking self-directed learning using head-mounted displays with pre-recorded videos had comparable skill acquisition to those attending traditional wet-lab tutorials. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Avhad, Kiran C.; Patil, Dinesh S.; Chitrambalam, S.; Sreenath, M. C.; Joe, I. Hubert; Sekar, Nagaiyan
2018-05-01
Four new coumarin hybrid styryl dyes are synthesized by condensing 4-(7-(diethylamino)-2-oxo-2H-chromen-3-yl)-2-morpholinothiazole-5-carbaldehyde with dicyanovinylene containing active methylene intermediates and their linear and non-linear optical properties are studied. The dye having dicyanovinylene-isophorone acceptor displayed a large Stokes shift of 3702-4795 cm-1 in non-polar to polar solvent respectively. The dyes exhibit a good charge transfer characteristics and positive emission solvatochromism (∼50 nm-72 nm) in non-polar to a polar solvent which is well supported by multi-linear regression analysis. Viscosity induced enhancement study in ethanol/polyethylene glycol-400 system shows 2.71-6.78 fold increase in emission intensity. The intra and twisted-intramolecular charge transfer (ICT-TICT) characteristics were established using emission solvatochromism, polarity plots, generalised Mullikan-Hush (GMH) analysis and optimized geometry. A dye having the highest charge transfer dipole moment relatively possess the maximum two-photon absorption cross-section area (KK-1 = 165-207 GM) which was established using theoretical two-level model. The NLO properties have been investigated employing solvatochromic and computational methods and were found to be directly proportional to the polarity of the solvent. Z-scan results reveal that the dyes KK-1 and KK-2 possesses reverse saturable kind of behaviour whereas KK-3 and KK-4 show saturable kind of behaviour. From the experimental and theoretical data, these coumarin thiazole hybrid dyes can be considered as promising candidates for FMR and NLOphores.
Differential polarization laser scanning microscopy: biological applications
NASA Astrophysics Data System (ADS)
Steinbach, G.; Besson, F.; Pomozi, I.; Garab, G.
2005-09-01
With the aid of a differential polarization (DP) apparatus, developed in our laboratory and attached to our laser scanning confocal microscope, we can measure the magnitude and spatial distribution of 8 different DP quantities: linear and circular dichroism (LD&CD), linear and circular anisotropy of the emission (R and CPL, confocal), fluorescence detected dichroisms (FDLD&FDCD, confocal), linear birefringence (LB), and the degree of polarization of fluorescence emission (P, confocal). The attachment uses high frequency modulation and subsequent demodulation, via lock-in amplifier, of the detected intensity values, and records and displays pixel-by-pixel the measured DP quantity. These microscopic DP data carry important physical information on the molecular architecture of anisotropically organized samples. Microscopic DP measurements are thought to be of particular importance in biology. In most biological samples anisotropy is difficult to determine with conventional, macroscopic DP measurements and microscopic variations are of special significance. In this paper, we describe the method of LB imaging. Using magnetically oriented isolated chloroplasts trapped in polyacrylamide gel, we demonstrate that LB can be determined with high sensitivity and good spatial resolution. Granal thylakoid membranes in edge-aligned orientation exhibited strong LB, with large variations in its sign and magnitude. In face-aligned position LB was considerably weaker, and tended to vanish when averaged for the whole image. The strong local variations are attributed to the inherent heterogeneity of the membranes, i.e. to their internal differentiation into multilamellar, stacked membranes (grana), and single thylakoids (stroma membranes). Further details and applications of our DP-LSM will be published elsewhere.
Dhole, Sumit; Stern, Caitlin A; Servedio, Maria R
2018-04-01
The evolution of mating displays as indicators of male quality has been the subject of extensive theoretical and empirical research for over four decades. Research has also addressed the evolution of female mate choice favoring such indicators. Yet, much debate still exists about whether displays can evolve through the indirect benefits of female mate choice. Here, we use a population genetic model to investigate how the extent to which females can directly detect male quality influences the evolution of female choosiness and male displays. We use a continuum framework that incorporates indicator mechanisms that are traditionally modeled separately. Counter to intuition, we find that intermediate levels of direct detection of male quality can facilitate, rather than impede, the evolution of female choosiness and male displays in broad regions of this continuum. We examine how this evolution is driven by selective forces on genetic quality and on the display, and find that direct detection of male quality results in stronger indirect selection favoring female choosiness. Our results imply that displays maybe more likely to evolve when female choosiness has already evolved to discriminate perceptible forms of male quality. They also highlight the importance of considering general female choosiness, as well as preference, in studies of "good genes." © 2018 The Author(s). Evolution © 2018 The Society for the Study of Evolution.
Use of Linear and Circular Polarization: The Secret LCD Screen and 3D Cinema
ERIC Educational Resources Information Center
Richtberg, Stefan; Girwidz, Raimund
2017-01-01
References to everyday life are important for teaching physics. Discussing polarization phenomena, liquid crystal displays (LCDs) and 3D cinemas provide such references. In this paper we describe experiments to support students' understanding of linearly polarized light as well as the phenomenon of inverted colors using a secret LCD screen.…
16 CFR 303.13 - Sale of remnants and products made of remnants.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ACTS OF CONGRESS RULES AND REGULATIONS UNDER THE TEXTILE FIBER PRODUCTS IDENTIFICATION ACT § 303.13... information as “remnants of undetermined fiber content.” (2) Where such remnants of fabrics are displayed for... conjunction with such display, stating with respect to required fiber content disclosure that the goods are...
Liu, Qin; Zhu, Xu; Huo, Zhaohui; He, Xulun; Liang, Yong; Xu, Maotian
2012-08-15
Graphene (GR) was synthesized through electrochemical reduction of graphene oxide and characterized by spectroscopic and electrochemical techniques. Polyvinylpyrrolidone (PVP)/graphene modified glassy carbon electrode (PVP/GR/GCE) was prepared and applied for the fabrication of dopamine (DA) sensors without the interference of ascorbic acid (AA). Compared to bare GCE, an increase of current signal was observed, demonstrating that PVP/GR/GCE exhibited favorable electron transfer kinetics and electrocatalytic activity towards the oxidation of dopamine. Furthermore, PVP/GR/GCE exhibited good ability to suppress the background current from large excess ascorbic acid. Amperometric response results show that the PVP based sensor displayed a wide linear range of 5×10(-10) to 1.13×10(-3) mol/L DA with a correlation coefficient of 0.9990 and a detection limit of 0.2 nM (S/N=3). The determination of dopamine in urine and human serum samples were studied. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kaur, Manjot; Mehta, Surinder K.; Kansal, Sushil Kumar
2017-06-01
This paper reports the carbonization assisted green approach for the fabrication of nitrogen doped graphene quantum dots (N-GQDs). The obtained N-GQDs displayed good water dispersibility and stability in the wide pH range. The as synthesized N-GQDs were used as a fluorescent probe for the sensing of explosive 2,4,6-trinitrophenol (TNP) in aqueous medium based on fluorescence resonance energy transfer (FRET), molecular interactions and charge transfer mechanism. The quenching efficiency was found to be linear in proportion to the TNP concentration within the range of 0-16 μM with detection limit (LOD) of 0.92 μM. The presented method was successfully applied to the sensing of TNP in tap and lake water samples with satisfactory results. Thus, N-GQDs were used as a selective, sensitive and turn off fluorescent sensor for the detection of perilous water contaminant i.e. TNP.
Kaur, Manjot; Mehta, Surinder K; Kansal, Sushil Kumar
2017-06-05
This paper reports the carbonization assisted green approach for the fabrication of nitrogen doped graphene quantum dots (N-GQDs). The obtained N-GQDs displayed good water dispersibility and stability in the wide pH range. The as synthesized N-GQDs were used as a fluorescent probe for the sensing of explosive 2,4,6-trinitrophenol (TNP) in aqueous medium based on fluorescence resonance energy transfer (FRET), molecular interactions and charge transfer mechanism. The quenching efficiency was found to be linear in proportion to the TNP concentration within the range of 0-16μM with detection limit (LOD) of 0.92μM. The presented method was successfully applied to the sensing of TNP in tap and lake water samples with satisfactory results. Thus, N-GQDs were used as a selective, sensitive and turn off fluorescent sensor for the detection of perilous water contaminant i.e. TNP. Copyright © 2017 Elsevier B.V. All rights reserved.
Financial Time Series Prediction Using Elman Recurrent Random Neural Networks
Wang, Jie; Wang, Jun; Fang, Wen; Niu, Hongli
2016-01-01
In recent years, financial market dynamics forecasting has been a focus of economic research. To predict the price indices of stock markets, we developed an architecture which combined Elman recurrent neural networks with stochastic time effective function. By analyzing the proposed model with the linear regression, complexity invariant distance (CID), and multiscale CID (MCID) analysis methods and taking the model compared with different models such as the backpropagation neural network (BPNN), the stochastic time effective neural network (STNN), and the Elman recurrent neural network (ERNN), the empirical results show that the proposed neural network displays the best performance among these neural networks in financial time series forecasting. Further, the empirical research is performed in testing the predictive effects of SSE, TWSE, KOSPI, and Nikkei225 with the established model, and the corresponding statistical comparisons of the above market indices are also exhibited. The experimental results show that this approach gives good performance in predicting the values from the stock market indices. PMID:27293423
NASA Technical Reports Server (NTRS)
Lee, Timothy J.; Langhoff, Stephen R. (Technical Monitor)
1995-01-01
The quality of fundamental vibrational frequencies determined using the CCSD(T) method (singles and doubles coupled-cluster theory plus a perturbational estimate of the effects of connected triple excitations) is shown to be very good, usually predicting band centers to within plus or minus 8 per centimeter. This approach is applied to several molecules of interest in atmospheric chemistry, such as HNO, cis-FONO, cis-ClONO, and ClOOH. The HNO molecule displays a large and unusual anharmonicity in the H-N stretch. For the calculation of ultraviolet (UV) spectra, the linear response CCSD (LRCCSD) approach (which is equivalent to EOM-CCSD) has been shown to yield vertical excitation energies that are accurate to approximately equal to 0.1 eV for singly excited electronic states. This method together with more approximate methods is used to examine the UV spectra of several molecules important in stratospheric chemistry, including HOCl, Cl2O, ClONO2, HONO2, ClOOCl, ClOOH, and HOOH.
NASA Technical Reports Server (NTRS)
Stevens, M. E.; Roskam, J.
1985-01-01
The problem of determining the vertical axis control requirements for landing a VTOL aircraft on a moving ship deck in various sea states is examined. Both a fixed-base piloted simulation and a nonpiloted simulation were used to determine the landing performance as influenced by thrust-to-weight ratio, vertical damping, and engine lags. The piloted simulation was run using a fixed-based simulator at Ames Research center. Simplified versions of an existing AV-8A Harrier model and an existing head-up display format were used. The ship model used was that of a DD963 class destroyer. Simplified linear models of the pilot, aircraft, ship motion, and ship air-wake turbulence were developed for the nonpiloted simulation. A unique aspect of the nonpiloted simulation was the development of a model of the piloting strategy used for shipboard landing. This model was refined during the piloted simulation until it provided a reasonably good representation of observed pilot behavior.
Peng, Mingzeng; Li, Zhou; Liu, Caihong; Zheng, Qiang; Shi, Xieqing; Song, Ming; Zhang, Yang; Du, Shiyu; Zhai, Junyi; Wang, Zhong Lin
2015-03-24
A high-resolution dynamic tactile/pressure display is indispensable to the comprehensive perception of force/mechanical stimulations such as electronic skin, biomechanical imaging/analysis, or personalized signatures. Here, we present a dynamic pressure sensor array based on pressure/strain tuned photoluminescence imaging without the need for electricity. Each sensor is a nanopillar that consists of InGaN/GaN multiple quantum wells. Its photoluminescence intensity can be modulated dramatically and linearly by small strain (0-0.15%) owing to the piezo-phototronic effect. The sensor array has a high pixel density of 6350 dpi and exceptional small standard deviation of photoluminescence. High-quality tactile/pressure sensing distribution can be real-time recorded by parallel photoluminescence imaging without any cross-talk. The sensor array can be inexpensively fabricated over large areas by semiconductor product lines. The proposed dynamic all-optical pressure imaging with excellent resolution, high sensitivity, good uniformity, and ultrafast response time offers a suitable way for smart sensing, micro/nano-opto-electromechanical systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lieou, Charles Ka Cheong; Daub, Eric G.; Ecke, Robert E.
Rock materials often display long-time relaxation, commonly termed aging or “slow dynamics”, after the cessation of acoustic perturbations. In this paper, we focus on unconsolidated rock materials and propose to explain such nonlinear relaxation through the Shear-Transformation-Zone (STZ) theory of granular media, adapted for small stresses and strains. The theory attributes the observed relaxation to the slow, irreversible change of positions of constituent grains, and posits that the aging process can be described in three stages: fast recovery before some characteristic time associated with the subset of local plastic events or grain rearrangements with a short time scale, log-linear recoverymore » of the elastic modulus at intermediate times, and gradual turnover to equilibrium steady-state behavior at long times. Here we demonstrate good agreement with experiments on aging in granular materials such as simulated fault gouge after an external disturbance. These results may provide insights into observed modulus recovery after strong shaking in the near surface region of earthquake zones.« less
Slow dynamics and strength recovery in unconsolidated granular earth materials: a mechanistic theory
Lieou, Charles Ka Cheong; Daub, Eric G.; Ecke, Robert E.; ...
2017-09-08
Rock materials often display long-time relaxation, commonly termed aging or “slow dynamics”, after the cessation of acoustic perturbations. In this paper, we focus on unconsolidated rock materials and propose to explain such nonlinear relaxation through the Shear-Transformation-Zone (STZ) theory of granular media, adapted for small stresses and strains. The theory attributes the observed relaxation to the slow, irreversible change of positions of constituent grains, and posits that the aging process can be described in three stages: fast recovery before some characteristic time associated with the subset of local plastic events or grain rearrangements with a short time scale, log-linear recoverymore » of the elastic modulus at intermediate times, and gradual turnover to equilibrium steady-state behavior at long times. Here we demonstrate good agreement with experiments on aging in granular materials such as simulated fault gouge after an external disturbance. These results may provide insights into observed modulus recovery after strong shaking in the near surface region of earthquake zones.« less
Financial Time Series Prediction Using Elman Recurrent Random Neural Networks.
Wang, Jie; Wang, Jun; Fang, Wen; Niu, Hongli
2016-01-01
In recent years, financial market dynamics forecasting has been a focus of economic research. To predict the price indices of stock markets, we developed an architecture which combined Elman recurrent neural networks with stochastic time effective function. By analyzing the proposed model with the linear regression, complexity invariant distance (CID), and multiscale CID (MCID) analysis methods and taking the model compared with different models such as the backpropagation neural network (BPNN), the stochastic time effective neural network (STNN), and the Elman recurrent neural network (ERNN), the empirical results show that the proposed neural network displays the best performance among these neural networks in financial time series forecasting. Further, the empirical research is performed in testing the predictive effects of SSE, TWSE, KOSPI, and Nikkei225 with the established model, and the corresponding statistical comparisons of the above market indices are also exhibited. The experimental results show that this approach gives good performance in predicting the values from the stock market indices.
Slow Dynamics and Strength Recovery in Unconsolidated Granular Earth Materials: A Mechanistic Theory
NASA Astrophysics Data System (ADS)
Lieou, Charles K. C.; Daub, Eric G.; Ecke, Robert E.; Johnson, Paul A.
2017-10-01
Rock materials often display long-time relaxation, commonly termed aging or "slow dynamics," after the cessation of acoustic perturbations. In this paper, we focus on unconsolidated rock materials and propose to explain such nonlinear relaxation through the shear-transformation-zone theory of granular media, adapted for small stresses and strains. The theory attributes the observed relaxation to the slow, irreversible change of positions of constituent grains and posits that the aging process can be described in three stages: fast recovery before some characteristic time associated with the subset of local plastic events or grain rearrangements with a short time scale, log linear recovery of the elastic modulus at intermediate times, and gradual turnover to equilibrium steady state behavior at long times. We demonstrate good agreement with experiments on aging in granular materials such as simulated fault gouge after an external disturbance. These results may provide insights into observed modulus recovery after strong shaking in the near surface region of earthquake zones.
NASA Astrophysics Data System (ADS)
Qiang, Liangliang
A miniature wireless implantable electrochemical glucose system for continuous glucose monitoring with good selectivity, sensitivity, linearity and long term stability was developed. First, highly sensitive, long-term stable and reusable planar H2O2 microelectrodes have been fabricated by microlithography. These electrodes composed of a 300 nm Pt black layer situated on a 5 um thick Au layer, provide effective protection to the underlying chromium adhesion layer. Using repeated cyclic voltammetric sweeps in flowing buffer solution, highly sensitive Pt black working electrodes were realized with five-decade linear dynamic range and low detection limit (10 nM) for H2O2 at low oxidation potentials. Second, a highly sensitive, low cost and flexible microwire biosensor was described using 25-mum thick gold wire as working electrode together with 125-mum thick Pt/Ir and Ag wires as counter and reference electrode, embedded within a PDMS-filled polyethylene tube. Surface area and activity of sensor was enhanced by converting gold electrode to nanoporous configuration followed by electrodeposition of platinum black. Glucose oxidase based biosensors by electrodeposition of poly(o-phenylenediamine) and glucose oxidase on the working electrode, displayed a higher glucose sensitivity (1.2 mA mM-1 cm-2) than highest literature reported. In addition it exhibits wide detection range (up to 20 mM) and selectivity (>95%). Third, novel miniaturized and flexible microelectrode arrays with 8 of 25 mum electrodes displayed the much needed 3D diffusion profiles similar to a single 25 mum microelectrode, but with one order increase in current levels. These microelectrode arrays displayed a H2O2 sensitivity of 13 mA mM-1 cm-2, a wide dynamic range of 100 nM to 10 mM, limit of detection of 10 nM. These microwire based edge plane microsensors incorporated flexibility, miniaturization and low operation potential are an promising approach for continuous in vivo metabolic monitoring. Fourth, homemade miniature wireless potentisotat was fabricated based on low power consumption integrated circuits and surface mount parts. The miniature wireless potentisotat with up to two week life-time for continuous glucose sensing has a size less than 9x22x10 mm and weight ˜3.4 grams. Primary in vivo experiment showed homemade system has the exactly same respond and trend as commercial glucose meter.
Sexual selection and sex linkage.
Kirkpatrick, Mark; Hall, David W
2004-04-01
Some animal groups, such as birds, seem prone to extreme forms of sexual selection. One contributing factor may be sex linkage of genes affecting male displays and female preferences. Here we show that sex linkage can have substantial effects on the genetic correlation between these traits and consequently for Fisher's runaway and the good-genes mechanisms of sexual selection. Under some kinds of sex linkage (e.g. Z-linked preferences), a runaway is more likely than under autosomal inheritance, while under others (e.g., X-linked preferences and autosomal displays), the good-genes mechanism is particularly powerful. These theoretical results suggest empirical tests based on the comparative method.
NASA Astrophysics Data System (ADS)
Dupré, Ludovic; Marra, Marjorie; Verney, Valentin; Aventurier, Bernard; Henry, Franck; Olivier, François; Tirano, Sauveur; Daami, Anis; Templier, François
2017-02-01
We report the fabrication process and characterization of high resolution 873 x 500 pixels emissive arrays based on blue or green GaN/InGaN light emitting diodes (LEDs) at a reduced pixel pitch of 10 μm. A self-aligned process along with a combination of damascene metallization steps is presented as the key to create a common cathode which is expected to provide good thermal dissipation and prevent voltage drops between center and side of the micro LED matrix. We will discuss the challenges of a self-aligned technology related to the choice of a good P contact metal and will present our solutions for the realization of the metallic interconnections between the GaN contacts and the higher levels of metallization at such a small pixel pitch. Enhanced control of each technological step allows scalability of the process up to 4 inch LED wafers and production of high quality LED arrays. The very high brightness (up to 107 cd.m-2) and good external quantum efficiency (EQE) of the resulting device make these kind of micro displays suitable for augmented reality or head up display applications.
Non-linear optics of ultrastrongly coupled cavity polaritons
NASA Astrophysics Data System (ADS)
Crescimanno, Michael; Liu, Bin; McMaster, Michael; Singer, Kenneth
2016-05-01
Experiments at CWRU have developed organic cavity polaritons that display world-record vacuum Rabi splittings of more than an eV. This ultrastrongly coupled polaritonic matter is a new regime for exploring non-linear optical effects. We apply quantum optics theory to quantitatively determine various non-linear optical effects including types of low harmonic generation (SHG and THG) in single and double cavity polariton systems. Ultrastrongly coupled photon-matter systems such as these may be the foundation for technologies including low-power optical switching and computing.
Effects of Motion and Figural Goodness on Haptic Object Perception in Infancy.
ERIC Educational Resources Information Center
Streri, Arlette; Spelke, Elizabeth S.
1989-01-01
After haptic habituation to a ring display, infants perceived the rings in two experiments as parts of one connected object. In both haptic and visual modes, infants appeared to perceive object unity by analyzing motion but not by analyzing figural goodness. (RH)
Electro-optical switching and memory display device
Skotheim, T.A.; O'Grady, W.E.; Linkous, C.A.
1983-12-29
An electro-optical display device having a housing with wall means including one transparent wall and at least one other wall. Counter electrodes are positioned on the transparent wall and display electrodes are positioned on the other wall with both electrodes in electrically conductive relationship with an electrolyte. Circuits means are connected to the display and counter electrodes to apply different predetermined control potentials between them. The display electrodes are covered with a thin electrically conductive polymer film that is characterized according to the invention by having embedded in it pigment molecules as counter ions. The display device is operable to be switched to a plurality of different visual color states at an exceptionally rapid switching rate while each of the color states is characterized by possessing good color intensity and definition.
Electro-optical switching and memory display device
Skotheim, Terje A.; O'Grady, William E.; Linkous, Clovis A.
1986-01-01
An electro-optical display device having a housing with wall means including one transparent wall and at least one other wall. Counter electrodes are positioned on the transparent wall and display electrodes are positioned on the other wall with both electrodes in electrically conductive relationship with an electrolyte. Circuit means are connected to the display and counter electrodes to apply different predetermined control potentials between them. The display electrodes are covered with a thin electrically conductive polymer film that is characterized according to the invention by having embedded in it pigment molecules as counter ions. The display device is operable to be switched to a plurality of different visual color states at an exceptionally rapid switching rate while each of the color states is characterized by possessing good color intensity and definition.
Du, Weiqi; Zhang, Gaofei; Ye, Liangchen
2016-01-01
Micromirror-based scanning displays have been the focus of a variety of applications. Lissajous scanning displays have advantages in terms of power consumption; however, the image quality is not good enough. The main reason for this is the varying size and the contrast ratio of pixels at different positions of the image. In this paper, the Lissajous scanning trajectory is analyzed and a new method based on the diamond pixel is introduced to Lissajous displays. The optical performance of micromirrors is discussed. A display system demonstrator is built, and tests of resolution and contrast ratio are conducted. The test results show that the new Lissajous scanning method can be used in displays by using diamond pixels and image quality remains stable at different positions. PMID:27187390
Du, Weiqi; Zhang, Gaofei; Ye, Liangchen
2016-05-11
Micromirror-based scanning displays have been the focus of a variety of applications. Lissajous scanning displays have advantages in terms of power consumption; however, the image quality is not good enough. The main reason for this is the varying size and the contrast ratio of pixels at different positions of the image. In this paper, the Lissajous scanning trajectory is analyzed and a new method based on the diamond pixel is introduced to Lissajous displays. The optical performance of micromirrors is discussed. A display system demonstrator is built, and tests of resolution and contrast ratio are conducted. The test results show that the new Lissajous scanning method can be used in displays by using diamond pixels and image quality remains stable at different positions.
The processing of linear perspective and binocular information for action and perception.
Bruggeman, Hugo; Yonas, Albert; Konczak, Jürgen
2007-04-08
To investigate the processing of linear perspective and binocular information for action and for the perceptual judgment of depth, we presented viewers with an actual Ames trapezoidal window. The display, when presented perpendicular to the line of sight, provided perspective information for a rectangular window slanted in depth, while binocular information specified a planar surface in the fronto-parallel plane. We compared pointing towards the display-edges with perceptual judgment of their positions in depth as the display orientation was varied under monocular and binocular view. On monocular trials, pointing and depth judgment were based on the perspective information and failed to respond accurately to changes in display orientation because pictorial information did not vary sufficiently to specify the small differences in orientation. For binocular trials, pointing was based on binocular information and precisely matched the changes in display orientation whereas depth judgment was short of such adjustment and based upon both binocular and perspective-specified slant information. The finding, that on binocular trials pointing was considerably less responsive to the illusion than perceptual judgment, supports an account of two separate processing streams in the human visual system, a ventral pathway involved in object recognition and a dorsal pathway that produces visual information for the control of actions. Previously, similar differences between perception and action were explained by an alternate explanation, that is, viewers selectively attend to different parts of a display in the two tasks. The finding that under monocular view participants responded to perspective information in both the action and the perception task rules out the attention-based argument.
Low energy switching driver for printed electrochromic displays
NASA Astrophysics Data System (ADS)
Ionescu, Ciprian; Dobre, Robert Alexandru
2016-12-01
This paper continues our investigations in relatively new developed printed electrochromic displays (ECDs). There are some advantages of ECDs that recommend them for specific low end and short time disposable display applications, for instance the ECD devices present low power consumption (they are non-emissive, reflective, i.e. passive) and have a good viewing angle, looking like ink on paper. It is to note that these displays are still in research, and partly present on the market. There are a lot of papers regarding the chemistry and electro-chemistry of the device, but very few about concrete schematics for driving these displays. Due to their low penetration in applications, and due to lack of standardization, there are not yet realized custom drivers in form of integrated circuits. The driving of these circuits is not at all so simple. These are very sensitive devices in what it concerns exceeding the drive pulse duration and voltage level. In order to take full advantage of the low power consumption of this device, a good driver circuitry needs to be realized also in the "low power" class. We propose in this paper an original driving circuit, that has very low consumption and that can be even supplied by a supercapacitor or by a printed battery. The whole structure can be further integrated as a system on foil.
Wind tunnel wall effects in a linear oscillating cascade
NASA Technical Reports Server (NTRS)
Buffum, Daniel H.; Fleeter, Sanford
1991-01-01
Experiments in a linear oscillating cascade reveal that the wind tunnel walls enclosing the airfoils have, in some cases, a detrimental effect on the oscillating cascade aerodynamics. In a subsonic flow field, biconvex airfoils are driven simultaneously in harmonic, torsion-mode oscillations for a range of interblade phase angle values. It is found that the cascade dynamic periodicity - the airfoil to airfoil variation in unsteady surface pressure - is good for some values of interblade phase angle but poor for others. Correlation of the unsteady pressure data with oscillating flat plate cascade predictions is generally good for conditions where the periodicity is good and poor where the periodicity is poor. Calculations based upon linearized unsteady aerodynamic theory indicate that pressure waves reflected from the wind tunnel walls are responsible for the cases where there is poor periodicity and poor correlation with the predictions.
Linear dispersion relation for the mirror instability in context of the gyrokinetic theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Porazik, Peter; Johnson, Jay R.
2013-10-15
The linear dispersion relation for the mirror instability is discussed in context of the gyrokinetic theory. The objective is to provide a coherent view of different kinetic approaches used to derive the dispersion relation. The method based on gyrocenter phase space transformations is adopted in order to display the origin and ordering of various terms.
Maillot, Matthieu; Ferguson, Elaine L; Drewnowski, Adam; Darmon, Nicole
2008-06-01
Nutrient profiling ranks foods based on their nutrient content. They may help identify foods with a good nutritional quality for their price. This hypothesis was tested using diet modeling with linear programming. Analyses were undertaken using food intake data from the nationally representative French INCA (enquête Individuelle et Nationale sur les Consommations Alimentaires) survey and its associated food composition and price database. For each food, a nutrient profile score was defined as the ratio between the previously published nutrient density score (NDS) and the limited nutrient score (LIM); a nutritional quality for price indicator was developed and calculated from the relationship between its NDS:LIM and energy cost (in euro/100 kcal). We developed linear programming models to design diets that fulfilled increasing levels of nutritional constraints at a minimal cost. The median NDS:LIM values of foods selected in modeled diets increased as the levels of nutritional constraints increased (P = 0.005). In addition, the proportion of foods with a good nutritional quality for price indicator was higher (P < 0.0001) among foods selected (81%) than among foods not selected (39%) in modeled diets. This agreement between the linear programming and the nutrient profiling approaches indicates that nutrient profiling can help identify foods of good nutritional quality for their price. Linear programming is a useful tool for testing nutrient profiling systems and validating the concept of nutrient profiling.
The cognitive science of visual-spatial displays: implications for design.
Hegarty, Mary
2011-07-01
This paper reviews cognitive science perspectives on the design of visual-spatial displays and introduces the other papers in this topic. It begins by classifying different types of visual-spatial displays, followed by a discussion of ways in which visual-spatial displays augment cognition and an overview of the perceptual and cognitive processes involved in using displays. The paper then argues for the importance of cognitive science methods to the design of visual displays and reviews some of the main principles of display design that have emerged from these approaches to date. Cognitive scientists have had good success in characterizing the performance of well-defined tasks with relatively simple visual displays, but many challenges remain in understanding the use of complex displays for ill-defined tasks. Current research exemplified by the papers in this topic extends empirical approaches to new displays and domains, informs the development of general principles of graphic design, and addresses current challenges in display design raised by the recent explosion in availability of complex data sets and new technologies for visualizing and interacting with these data. Copyright © 2011 Cognitive Science Society, Inc.
An efficient polymeric micromotor doped with Pt nanoparticle@carbon nanotubes for complex bio-media.
Li, Yana; Wu, Jie; Xie, Yuzhe; Ju, Huangxian
2015-04-14
A highly efficient polymeric tubular micromotor doped with Pt nanoparticle@carbon nanotubes is fabricated by template-assisted electrochemical growth. The micromotors preserve good navigation in multi-media and surface modification, along with simple synthesis, easy functionalization and good biocompatibility, displaying great promise in biological applications.
Chen, Hsiao-Chien; Tu, Yi-Ming; Hou, Chung-Che; Lin, Yu-Chen; Chen, Ching-Hsiang; Yang, Kuang-Hsuan
2015-03-31
A water-dispersible multi-walled carbon nanotubes (MWCNTs) derivative, MWCNTs-1-one-dihydroxypyridine (MWCNTs-Py) was synthesis via Friedel-Crafts chemical acylation. Raman spectra demonstrated the conjugated level of MWCNTs-Py was retained after this chemical modification. MWCNTs-Py showed dual hydrogen peroxide (H2O2) and glucose detections without mutual interference by adjusting pH value. It was sensitive to H2O2 in acidic solution and displayed the high performances of sensitivity, linear range, response time and stability; meanwhile it did not respond to H2O2 in neutral solution. In addition, this positively charged MWCNTs-Py could adsorb glucose oxidase (GOD) by electrostatic attraction. MWCNTs-Py-GOD/GC electrode showed the direct electron transfer (DET) of GOD with a pair of well-defined redox peaks, attesting the bioactivity of GOD was retained due to the non-destroyed immobilization. The high surface coverage of active GOD (3.5×10(-9) mol cm(-2)) resulted in exhibiting a good electrocatalytic activity toward glucose. This glucose sensor showed high sensitivity (68.1 μA mM(-1) cm(-2)) in a linear range from 3 μM to 7 mM in neutral buffer solution. The proposed sensor could distinguish H2O2 and glucose, thus owning high selectivity and reliability. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Queiros-Conde, D.; Foucher, F.; Mounaïm-Rousselle, C.; Kassem, H.; Feidt, M.
2008-12-01
Multi-scale features of turbulent flames near a wall display two kinds of scale-dependent fractal features. In scale-space, an unique fractal dimension cannot be defined and the fractal dimension of the front is scale-dependent. Moreover, when the front approaches the wall, this dependency changes: fractal dimension also depends on the wall-distance. Our aim here is to propose a general geometrical framework that provides the possibility to integrate these two cases, in order to describe the multi-scale structure of turbulent flames interacting with a wall. Based on the scale-entropy quantity, which is simply linked to the roughness of the front, we thus introduce a general scale-entropy diffusion equation. We define the notion of “scale-evolutivity” which characterises the deviation of a multi-scale system from the pure fractal behaviour. The specific case of a constant “scale-evolutivity” over the scale-range is studied. In this case, called “parabolic scaling”, the fractal dimension is a linear function of the logarithm of scale. The case of a constant scale-evolutivity in the wall-distance space implies that the fractal dimension depends linearly on the logarithm of the wall-distance. We then verified experimentally, that parabolic scaling represents a good approximation of the real multi-scale features of turbulent flames near a wall.
Dezawa, Akira; Sairyo, Koichi
2014-05-01
Organic electroluminescence displays (OELD) use organic materials that self-emit light with the passage of an electric current. OELD provide high contrast, excellent color reproducibility at low brightness, excellent video images, and less restricted viewing angles. OELD are thus promising for medical use. This study compared the utility of an OELD with conventional liquid crystal displays (LCD) for imaging in orthopedic endoscopic surgery. One OELD and two conventional LCD that were indistinguishable in external appearance were used in this study. Images from 18 patients were displayed simultaneously on three monitors and evaluated by six orthopedic surgeons with extensive surgical experience. Images were shown for 2 min, repeated twice, and viewed from the front and side (diagonally). Surgeon rated both clinical utility (12 parameters) and image quality (11 parameters) for each image on a 5-point scale: 1, very good; 2, good; 3, average; 4, poor; and 5, very poor. For clinical utility in 16 percutaneous endoscopic discectomy cases, mean scores for all 12 parameters were significantly better on the OELD than on the LCD, including organ distinguishability (2.1 vs 3.2, respectively), lesion identification (2.2 vs 3.1), and overall viewing impression (2.1 vs 3.1). For image quality, all 11 parameters were better on the OELD than on LCD. Significant differences were identified in six parameters, including contrast (1.8 vs 2.9), color reproducibility in dark areas (1.8 vs 2.9), and viewing angle (2.2 vs 2.9). The high contrast and excellent color reproducibility of the OELD reduced the constraints of imaging under endoscopy, in which securing a field of view may be difficult. Distinguishability of organs was good, including ligaments, dura mater, nerves, and adipose tissue, contributing to good stereoscopic images of the surgical field. These findings suggest the utility of OELD for excellent display of surgical images and for enabling safe and highly accurate endoscopic surgery. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Performance of NCAP projection displays
NASA Astrophysics Data System (ADS)
Jones, Philip J.; Tomita, Akira; Wartenberg, Mark
1991-08-01
Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.
Color quality management in advanced flat panel display engines
NASA Astrophysics Data System (ADS)
Lebowsky, Fritz; Neugebauer, Charles F.; Marnatti, David M.
2003-01-01
During recent years color reproduction systems for consumer needs have experienced various difficulties. In particular, flat panels and printers could not reach a satisfactory color match. The RGB image stored on an Internet server of a retailer did not show the desired colors on a consumer display device or printer device. STMicroelectronics addresses this important color reproduction issue inside their advanced display engines using novel algorithms targeted for low cost consumer flat panels. Using a new and genuine RGB color space transformation, which combines a gamma correction Look-Up-Table, tetrahedrization, and linear interpolation, we satisfy market demands.
Cost Estimating Relationships for U.S. Navy Ships
1983-09-01
ORGANIZATION NAME AND ADDRESS Institute for Defense Analyses iBOl North Beauregard Street Alexandria, Virginia 22311 10. PROGRAM ELEMENT, PROJECT ...linear CER also is displayed. In addi- tion. Table S-1 displays the total observed cost, the total estimated cost, and the percent difference...report provided by program year a total end cost for each ship by hull number including outfitting and post delivery costs. This end cost does not
Direction of Auditory Pitch-Change Influences Visual Search for Slope From Graphs.
Parrott, Stacey; Guzman-Martinez, Emmanuel; Orte, Laura; Grabowecky, Marcia; Huntington, Mark D; Suzuki, Satoru
2015-01-01
Linear trend (slope) is important information conveyed by graphs. We investigated how sounds influenced slope detection in a visual search paradigm. Four bar graphs or scatter plots were presented on each trial. Participants looked for a positive-slope or a negative-slope target (in blocked trials), and responded to targets in a go or no-go fashion. For example, in a positive-slope-target block, the target graph displayed a positive slope while other graphs displayed negative slopes (a go trial), or all graphs displayed negative slopes (a no-go trial). When an ascending or descending sound was presented concurrently, ascending sounds slowed detection of negative-slope targets whereas descending sounds slowed detection of positive-slope targets. The sounds had no effect when they immediately preceded the visual search displays, suggesting that the results were due to crossmodal interaction rather than priming. The sounds also had no effect when targets were words describing slopes, such as "positive," "negative," "increasing," or "decreasing," suggesting that the results were unlikely due to semantic-level interactions. Manipulations of spatiotemporal similarity between sounds and graphs had little effect. These results suggest that ascending and descending sounds influence visual search for slope based on a general association between the direction of auditory pitch-change and visual linear trend.
Cámara, María S; Ferroni, Félix M; De Zan, Mercedes; Goicoechea, Héctor C
2003-07-01
An improvement is presented on the simultaneous determination of two active ingredients present in unequal concentrations in injections. The analysis was carried out with spectrophotometric data and non-linear multivariate calibration methods, in particular artificial neural networks (ANNs). The presence of non-linearities caused by the major analyte concentrations which deviate from Beer's law was confirmed by plotting actual vs. predicted concentrations, and observing curvatures in the residuals for the estimated concentrations with linear methods. Mixtures of dextropropoxyphene and dipyrone have been analysed by using linear and non-linear partial least-squares (PLS and NPLSs) and ANNs. Notwithstanding the high degree of spectral overlap and the occurrence of non-linearities, rapid and simultaneous analysis has been achieved, with reasonably good accuracy and precision. A commercial sample was analysed by using the present methodology, and the obtained results show reasonably good agreement with those obtained by using high-performance liquid chromatography (HPLC) and a UV-spectrophotometric comparative methods.
A versatile stereoscopic visual display system for vestibular and oculomotor research.
Kramer, P D; Roberts, D C; Shelhamer, M; Zee, D S
1998-01-01
Testing of the vestibular system requires a vestibular stimulus (motion) and/or a visual stimulus. We have developed a versatile, low cost, stereoscopic visual display system, using "virtual reality" (VR) technology. The display system can produce images for each eye that correspond to targets at any virtual distance relative to the subject, and so require the appropriate ocular vergence. We elicited smooth pursuit, "stare" optokinetic nystagmus (OKN) and after-nystagmus (OKAN), vergence for targets at various distances, and short-term adaptation of the vestibulo-ocular reflex (VOR), using both conventional methods and the stereoscopic display. Pursuit, OKN, and OKAN were comparable with both methods. When used with a vestibular stimulus, VR induced appropriate adaptive changes of the phase and gain of the angular VOR. In addition, using the VR display system and a human linear acceleration sled, we adapted the phase of the linear VOR. The VR-based stimulus system not only offers an alternative to more cumbersome means of stimulating the visual system in vestibular experiments, it also can produce visual stimuli that would otherwise be impractical or impossible. Our techniques provide images without the latencies encountered in most VR systems. Its inherent versatility allows it to be useful in several different types of experiments, and because it is software driven it can be quickly adapted to provide a new stimulus. These two factors allow VR to provide considerable savings in time and money, as well as flexibility in developing experimental paradigms.
Human factors studies of control configurations for advanced transport aircraft
NASA Technical Reports Server (NTRS)
Snyder, Harry L.; Monty, Robert W.; Old, Joe
1985-01-01
This research investigated the threshold levels of display luminance contrast which were required to interpret static, achromatic, integrated displays of primary flight information. A four-factor within-subjects design was used to investigate the influences of type of flight variable information, the level of ambient illumination, the type of control input, and the size of the display symbology on the setting of these interpretability thresholds. A three-alternative forced choice paradigm was used in conjunction with the method of adjustments to obtain a measure of the upper limen of display luminance contrast needed to interpret a complex display of primary flight information. The pattern of results and the absolute magnitudes of the luminance contrast settings were found to be in good agreement with previously reported data from psychophysical investigations of display luminance contrast requirements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quam, W.; Del Duca, T.; Plake, W.
This paper describes a pocket-calculator-sized, neutron-sensitive, REM-responding personnel dosimeter that uses three tissue-equivalent cylindrical proportional counters as neutron-sensitive detectors. These are conventionally called Linear Energy Transfer (LET) counters. Miniaturized hybrid circuits are used for the linear pulse handling electronics, followed by a 256-channel ADC. A CMOS microprocessor is used to calculate REM exposure from the basic rads-tissue data supplied by the LET counters and also to provide timing and display functions. The instrument is used to continuously accumulate time in hours since reset, total counts accumulated, rads-tissue, and REM. The user can display any one of these items or amore » channel number (an aid in calibration) at any time. Such data are provided with a precision of +- 3% for a total exposure of 1 mREM over eight hours.« less
Use of Linear and Circular Polarization: The Secret LCD Screen and 3D Cinema
NASA Astrophysics Data System (ADS)
Richtberg, Stefan; Girwidz, Raimund
2017-10-01
References to everyday life are important for teaching physics. Discussing polarization phenomena, liquid crystal displays (LCDs) and 3D cinemas provide such references. In this paper we describe experiments to support students' understanding of linearly polarized light as well as the phenomenon of inverted colors using a secret LCD screen. Moreover we explain how 3D glasses work (when using polarizers) and introduce some experiments to point out why 3D cinemas use circularly polarized light instead of linearly polarized light. When using linearly polarized light, viewers must keep their head level all the time. Using circularly polarized light, this is not necessary.
Guler, Muhammet; Turkoglu, Vedat; Kivrak, Arif
2015-08-01
In the study, the electrochemical behavior of glucose oxidase (GOx) immobilized on poly([2,2';5',2″]-terthiophene-3'-carbaldehyde) (poly(TTP)) modified glassy carbon electrode (GCE) was investigated. The biosensor (poly(TTP)/GOx/GCE) showed a pair of redox peaks in 0.1 M phosphate buffer (pH 7.4) solution in the absence of oxygen the co-substrate of GOx. In here, Poly(TTP)/GOx/GCE biosensor acts as the co-substrate instead of oxygen. Upon the addition of glucose, the reduction and oxidation peak currents increased until the active site of GOx was fully saturated with glucose. The apparent m was estimated 26.13 mM from Lineweaver-Burk graph. The biosensor displayed a good stability and bioactivity. The biosensor showed a high sensitivity (56.1 nA/mM), a linear range (from 0.5 to 20.15 mM), and a good reproducibility with 3.6% of relative standard deviation. In addition, the interference currents of glycin, ascorbic acid, histidine, uric acid, dopamine, arginine, and fructose on GOx biosensor were investigated. All that substances exhibited an interference current under 10%. It was not shown a marked difference between GOx biosensor and spectrophotometric measurement of glucose in serum examples. UV-visible spectroscopy and scanning electron microscopy (SEM) experiments of the biosensor were also performed. Copyright © 2015 Elsevier B.V. All rights reserved.
Potentiometric Zinc Ion Sensor Based on Honeycomb-Like NiO Nanostructures
Abbasi, Mazhar Ali; Ibupoto, Zafar Hussain; Hussain, Mushtaque; Khan, Yaqoob; Khan, Azam; Nur, Omer; Willander, Magnus
2012-01-01
In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple hydrothermal growth method. The NiO nanostructures were characterized by field emission electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) techniques. The characterized NiO nanostructures were uniform, dense and polycrystalline in the crystal phase. In addition to this, the NiO nanostructures were used in the development of a zinc ion sensor electrode by functionalization with the highly selective zinc ion ionophore 12-crown-4. The developed zinc ion sensor electrode has shown a good linear potentiometric response for a wide range of zinc ion concentrations, ranging from 0.001 mM to 100 mM, with sensitivity of 36 mV/decade. The detection limit of the present zinc ion sensor was found to be 0.0005 mM and it also displays a fast response time of less than 10 s. The proposed zinc ion sensor electrode has also shown good reproducibility, repeatability, storage stability and selectivity. The zinc ion sensor based on the functionalized NiO nanostructures was also used as indicator electrode in potentiometric titrations and it has demonstrated an acceptable stoichiometric relationship for the determination of zinc ion in unknown samples. The NiO nanostructures-based zinc ion sensor has potential for analysing zinc ion in various industrial, clinical and other real samples. PMID:23202217
Cerium phosphate nanotubes: synthesis, characterization and biosensing
NASA Astrophysics Data System (ADS)
Meng, Ling; Yang, Lige; Zhou, Bo; Cai, Chenxin
2009-01-01
Cerium phosphate (CeP) nanotubes have been synthesized and confirmed by x-ray diffraction (XRD) and transmission electron microscopy (TEM). The 1D nanomaterial has a monoclinic crystal structure with a mean width of 15-20 nm and a length up to several micrometers. The nanotubes have been employed as electrode substrates for immobilization and direct electrochemistry of heme proteins/enzymes with myoglobin (Mb) as a model. The electrochemical characteristics of the Mb-CeP/GC electrode were studied by voltammetry. After being immobilized on the nanotubes, Mb can keep its natural structure and undergo effective direct electron transfer reaction with a pair of well-defined redox peaks at -(367 ± 3) mV (pH 7.5). The apparent electron transfer rate constant is (9.1 ± 1.4) s-1. The electrode displays good features in the electrocatalytic reduction of H2O2, and thus can be used as a biosensor for detecting the substrate with a low detection limit (0.5 ± 0.05 µM), a wide linear range (0.01-2 mM), high sensitivity (14.4 ± 1.2 µA mM-1), as well as good stability and reproducibility. CeP nanotubes can become a simple and effective biosensing platform for the integration of heme proteins/enzymes and electrodes, which can provide analytical access to a large group of enzymes for a wide range of bioelectrochemical applications.
Liu, Chao; Dong, Jing; Waterhouse, Geoffrey I N; Cheng, Ziqiang; Ai, Shiyun
2018-03-15
A sensitive sandwich-type electrochemical immunosensor was developed for the detection of avian leukosis virus subgroup J (ALV-J), which benefitted from multiple signal amplification involving graphene-perylene-3,4,9,10-tetracarboxylic acid nanocomposites (GR-PTCA), nanocellulose-Au NP composites (NC-Au) and the alkaline phosphatase (ALP) catalytic reaction. GR-PTCA nanocomposites on glassy carbon electrodes served as the immunosensor platform. Due to their excellent electrical conductivity and abundant polycarboxylic sites, the GR-PTCA nanocomposites allowed fast electron transfer and good immobilization of primary antibodies, thereby affording a strong immunosensor signal in the presence of ALV-J. The detected signal could be further amplified by the introduction of NC-Au composites as a carrier of secondary antibodies (Ab 2 ) and by harnessing the catalytic properties of Au and ALP. Under optimized testing conditions, the electrochemical immunosensor displayed excellent analytical performance for the detection of ALV-J, showing a linear current response from 10 2.08 to 10 4.0 TCID 50 /mL (TCID 50 : 50% tissue culture infective dose) with a low detection limit of 10 1.98 TCID 50 /mL (S/N = 3). In addition to high sensitivity, the immunosensor showed very good selectivity, reproducibility and operational stability, demonstrating potential application for the quantitative detection of ALV-J in clinical diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Paulk, C B; Tokach, M D; Nelssen, J L; Burnett, D D; Vaughn, M A; Phelps, K J; Dritz, S S; Derouchey, J M; Goodband, R D; Woodworth, J C; Houser, T A; Haydon, K D; Gonzalez, J M
2014-05-01
A total of 320 finishing pigs (PIC 327 × 1050; initially 98 kg) were used to determine the effects of adding Zn to diets containing ractopamine HCl (RAC) on muscle fiber type distribution, fresh chop color, and cooked meat characteristics. Dietary treatments were fed for approximately 35 d and consisted of a corn-soybean meal-based negative control (CON), a positive control diet with 10 mg/kg of RAC (RAC+), and the RAC+ diet plus 75, 150, or 225 mg/kg added Zn from either ZnO or Availa-Zn. Loins randomly selected from each treatment (n = 20) were evaluated using contrasts: CON vs. RAC+, interaction of Zn level × source, Zn level linear and quadratic polynomials, and Zn source. There were no Zn source effects or Zn source × level interactions throughout the study (P > 0.10). Pigs fed RAC+ had increased (P < 0.02) percentage type IIX and a tendency for increased (P = 0.10) percent type IIB muscle fibers. Increasing added Zn decreased (linear, P = 0.01) percentage type IIA and tended to increase (P = 0.09) IIX muscle fibers. On d 1, 2, 3, 4, and 5 of display, pork chops from pigs fed the RAC+ treatment had greater (P < 0.03) L* values compared to the CON. On d 0 and 3 of display, increasing added Zn tended to decrease (quadratic, P = 0.10) L* values and decreased (quadratic, P < 0.03) L* values on d 1, 2, 4, and 5. Pigs fed RAC+ had decreased (P < 0.05) a* values on d 1 and 4 of display and tended to have decreased (P < 0.10) a* values on d 0 and 2 compared to CON pork chops. Pork chops from the RAC+ treatment had a tendency for increased (P < 0.08) oxymyoglobin percentage compared to CON pork chops on d 1, 2, 4, and 5. On d 0, as dietary Zn increased in RAC+ diets, there was a decrease (linear, P < 0.01) in the formation of pork chop surface oxymyoglobin percentage. Metmyoglobin reducing ability (MRA) of pork chops on d 5 was decreased in the RAC+ group. Chops from pigs fed added Zn had increased (quadratic, P < 0.03) MRA on d 3 and 5 of the display period. There was a trend for increased (linear, P = 0.07) cooking loss with increasing Zn in RAC diets and treatments did not affect tenderness as measured by Warner-Bratzler shear force (P > 0.07). In conclusion, RAC+ diets produced chops that were lighter and less red but maintained a greater percentage of surface oxymyoglobin throughout a 5-d simulated retail display. Ractopamine reduced MRA at the end of the display period, but supplementing Zn to RAC diets restored MRA to near CON treatment levels at the end of the display period.
Statistical approach to the analysis of olive long-term pollen season trends in southern Spain.
García-Mozo, H; Yaezel, L; Oteros, J; Galán, C
2014-03-01
Analysis of long-term airborne pollen counts makes it possible not only to chart pollen-season trends but also to track changing patterns in flowering phenology. Changes in higher plant response over a long interval are considered among the most valuable bioindicators of climate change impact. Phenological-trend models can also provide information regarding crop production and pollen-allergen emission. The interest of this information makes essential the election of the statistical analysis for time series study. We analysed trends and variations in the olive flowering season over a 30-year period (1982-2011) in southern Europe (Córdoba, Spain), focussing on: annual Pollen Index (PI); Pollen Season Start (PSS), Peak Date (PD), Pollen Season End (PSE) and Pollen Season Duration (PSD). Apart from the traditional Linear Regression analysis, a Seasonal-Trend Decomposition procedure based on Loess (STL) and an ARIMA model were performed. Linear regression results indicated a trend toward delayed PSE and earlier PSS and PD, probably influenced by the rise in temperature. These changes are provoking longer flowering periods in the study area. The use of the STL technique provided a clearer picture of phenological behaviour. Data decomposition on pollination dynamics enabled the trend toward an alternate bearing cycle to be distinguished from the influence of other stochastic fluctuations. Results pointed to show a rising trend in pollen production. With a view toward forecasting future phenological trends, ARIMA models were constructed to predict PSD, PSS and PI until 2016. Projections displayed a better goodness of fit than those derived from linear regression. Findings suggest that olive reproductive cycle is changing considerably over the last 30years due to climate change. Further conclusions are that STL improves the effectiveness of traditional linear regression in trend analysis, and ARIMA models can provide reliable trend projections for future years taking into account the internal fluctuations in time series. Copyright © 2013 Elsevier B.V. All rights reserved.
Glassman, Patrick M; Chen, Yang; Balthasar, Joseph P
2015-10-01
Preclinical assessment of monoclonal antibody (mAb) disposition during drug development often includes investigations in non-human primate models. In many cases, mAb exhibit non-linear disposition that relates to mAb-target binding [i.e., target-mediated disposition (TMD)]. The goal of this work was to develop a physiologically-based pharmacokinetic (PBPK) model to predict non-linear mAb disposition in plasma and in tissues in monkeys. Physiological parameters for monkeys were collected from several sources, and plasma data for several mAbs associated with linear pharmacokinetics were digitized from prior literature reports. The digitized data displayed great variability; therefore, parameters describing inter-antibody variability in the rates of pinocytosis and convection were estimated. For prediction of the disposition of individual antibodies, we incorporated tissue concentrations of target proteins, where concentrations were estimated based on categorical immunohistochemistry scores, and with assumed localization of target within the interstitial space of each organ. Kinetics of target-mAb binding and target turnover, in the presence or absence of mAb, were implemented. The model was then employed to predict concentration versus time data, via Monte Carlo simulation, for two mAb that have been shown to exhibit TMD (2F8 and tocilizumab). Model predictions, performed a priori with no parameter fitting, were found to provide good prediction of dose-dependencies in plasma clearance, the areas under plasma concentration versu time curves, and the time-course of plasma concentration data. This PBPK model may find utility in predicting plasma and tissue concentration versus time data and, potentially, the time-course of receptor occupancy (i.e., mAb-target binding) to support the design and interpretation of preclinical pharmacokinetic-pharmacodynamic investigations in non-human primates.
NASA Technical Reports Server (NTRS)
Fletcher, Jay W.; Chen, Robert T. N.; Strasilla, Eric; Aiken, Edwin W. (Technical Monitor)
1995-01-01
Modern rotorcraft flight control system designs which promise to yield high vehicle response bandwidth and good gust rejection can benefit from the use of rotor-state feedbacks. The measurement of main rotor blade motions is also desirable to validate and improve rotorcraft simulation models, to identify high-order linear flight dynamics models, to provide rotor system health monitoring; during flight test, and to provide for correlation with acoustic measurements from wind tunnel and flight tests. However, few attempts have been made to instrument a flight vehicle in this manner, and no previous system has had the robustness and accuracy required for these diverse applications. A rotor blade motion measurement and estimation system has been developed by NASA and the U.S. Army for use on the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) helicopter. RASCAL is a UH-60 Blackhawk which is being modified at Ames Research Center in a phased development program for use in flight dynamics and controls, navigation, airspace management, and rotorcraft human factors research. The aircraft will feature a full-authority, digital, fly-by-wire research flight control system; a coupled ring laser gyro, differential GPS based navigation system; a stereoscopic color wide field of view helmet, mounted display; programmable panel mounted displays; and advanced navigation sensors. The rotor blade motion system is currently installed for data acquisition only, but will be integrated with the research flight control system when it is installed later this year.
The two-state dimer receptor model: a general model for receptor dimers.
Franco, Rafael; Casadó, Vicent; Mallol, Josefa; Ferrada, Carla; Ferré, Sergi; Fuxe, Kjell; Cortés, Antoni; Ciruela, Francisco; Lluis, Carmen; Canela, Enric I
2006-06-01
Nonlinear Scatchard plots are often found for agonist binding to G-protein-coupled receptors. Because there is clear evidence of receptor dimerization, these nonlinear Scatchard plots can reflect cooperativity on agonist binding to the two binding sites in the dimer. According to this, the "two-state dimer receptor model" has been recently derived. In this article, the performance of the model has been analyzed in fitting data of agonist binding to A(1) adenosine receptors, which are an example of receptor displaying concave downward Scatchard plots. Analysis of agonist/antagonist competition data for dopamine D(1) receptors using the two-state dimer receptor model has also been performed. Although fitting to the two-state dimer receptor model was similar to the fitting to the "two-independent-site receptor model", the former is simpler, and a discrimination test selects the two-state dimer receptor model as the best. This model was also very robust in fitting data of estrogen binding to the estrogen receptor, for which Scatchard plots are concave upward. On the one hand, the model would predict the already demonstrated existence of estrogen receptor dimers. On the other hand, the model would predict that concave upward Scatchard plots reflect positive cooperativity, which can be neither predicted nor explained by assuming the existence of two different affinity states. In summary, the two-state dimer receptor model is good for fitting data of binding to dimeric receptors displaying either linear, concave upward, or concave downward Scatchard plots.
Preparation of Proton Exchange Membranes and Lithium Batteries from Melamine-containing Ormosils
NASA Technical Reports Server (NTRS)
Tigelaar, Dean M.; Kinder, James D.; Meador, Mary Ann; Waldecker, James; Bennett, William R.
2004-01-01
Our laboratory has recently reported a series of rodcoil polymers for lithium batteries that display dimensionally stable films with good ionic conductivity. The rod segments consist of rigid linear and branched polyimides and the coil segments are polyethylene oxides (PEO). It has been proposed that good mechanical and transport properties are due to phase separation between the rod and coil segments. It was also observed that increased branching and molecular weight lead to increased conductivity. The following study was undertaken to assess the effects of phase separation in polyalkylene oxides connected by melamine linkages. Melamine was chosen as the linking unit because it provides a branching site, cation binding sites to help ionic transport between polymer chains, and the opportunity for self assembly through hydrogen bonding. Polymers were made by the reaction of cyanuric chloride with a series of amine-terminated alkylene oxides. A linear polymer was first made, followed by reaction of the third site on cyanuric chloride with varying ratios of monofunctional Jeffamine and (3-aminopropyl)triethoxysilane. The lithium trifluoromethane sulfonamide-doped polymers are then crosslinked through a sol-gel process to form free-standing films. Initial results have shown mechanically strong films with lithium conductivities on the order of 2 x 10(exp -5) S/cm at ambient temperature. In a separate study, organically modified silanes (Ormosils) that contain sulfonic acid derivatized melamines have been incorporated into proton exchange membranes. The membranes are made by reaction of the primary amine groups of various ratios of melamine derivative and difunctional Jeffamine (MW = 2000) with the epoxide group of (3-Glycidyloxypropyl)trimethoxysilane. The films were then cross-linked through a sol-gel process. Resulting sulfuric acid doped films are strong, flexible, and have proton conductivities on the order of 2 x l0(exp -2) S/cm (120 C, 25% relative humidity). Our best results have been observed when films contain 60% PEO and 40% sulfonated melamine.
Pilot scanning patterns while viewing cockpit displays of traffic information
NASA Technical Reports Server (NTRS)
Ellis, S. R.; Stark, L.
1981-01-01
Scanning eye movements of airline pilots were recorded while they judged air traffic situations displayed on cockpit displays of traffic information (CDTI). The observed 1st order transition patterns between points of interest on the display showed reliable deviation from those patterns predicted by the assumption of statistical independence. However, both patterns of transitions correlated quite well with each other. Accordingly, the assumption of independence provided a surprisingly good model of the results. Nevertheless, the deviation between the observed patterns of transition and that based on the assumption of independence was for all subjects in the direction of increased determinism. Thus, the results provide objective evidence consistent with the existence of "scanpaths" in the data.
NASA Astrophysics Data System (ADS)
Holter, Borre; Kamfjord, Thor G.; Fossum, Richard; Fagerberg, Ragnar
2000-08-01
The Norwegian based company PolyDisplayR ASA, in collaboration with the Norwegian Army Material Command and SINTEF, has refined, developed and shown with color and black/white technology demonstrators an electrically addressed Smectic A reflective LCD technology featuring: (1) Good contrast, all-round viewing angle and readability under all light conditions (no wash-out in direct sunlight). (2) Infinite memory -- image remains without power -- very low power consumption, no or very low radiation ('silent display') and narrow band updating. (3) Clear, sharp and flicker-free images. (4) Large number of gray tones and colors possible. (5) Simple construction and production -- reduced cost, higher yield, more robust and environmentally friendly. (6) Possibility for lighter, more robust and flexible displays based on plastic substrates. The results and future implementation possibilities for cockpit and soldier-system displays are discussed.
[A novel quantitative approach to study dynamic anaerobic process at micro scale].
Zhang, Zhong-Liang; Wu, Jing; Jiang, Jian-Kai; Jiang, Jie; Li, Huai-Zhi
2012-11-01
Anaerobic digestion is attracting more and more interests because of its advantages such as low cost and recovery of clean energy etc. In order to overcome the drawbacks of the existed methods to study the dynamic anaerobic process, a novel microscopical quantitative approach at the granule level was developed combining both the microdevice and the quantitative image analysis techniques. This experiment displayed the process and characteristics of the gas production at static state for the first time and the results indicated that the method was of satisfactory repeatability. The gas production process at static state could be divided into three stages including rapid linear increasing stage, decelerated increasing stage and slow linear increasing stage. The rapid linear increasing stage was long and the biogas rate was high under high initial organic loading rate. The results showed that it was feasible to make the anaerobic process to be carried out in the microdevice; furthermore this novel method was reliable and could clearly display the dynamic process of the anaerobic reaction at the micro scale. The results are helpful to understand the anaerobic process.
Near-Simultaneous Spectroscopic and Broadband Polarimetric Observations of Be Stars
NASA Technical Reports Server (NTRS)
Ghosh, K.; Iyengar, K. V. K.; Ramsey, B. D.; Austin, R. A.
1999-01-01
Near simultaneous optical spectroscopic (on four nights) and broadband linear continuum (B, V, R, and I bands) polarimetric (on seven nights) observations of 29 Be stars were carried out during 1993 November-December. The program Be stars displayed wavelength dependence of intrinsic polarizations with no frequency dependence of polarimetric position angles. Some of the Be stars displayed long-term polarization variability. The Be and Be-shell stars could not be distinguished from one another solely on the basis of their polarization values. Full widths at half-maximum of the H.alpha profiles and the intrinsic linear continuum polarizations are closely correlated with the projected rotational velocities of the program stars. Photospheric-absorption-corrected equivalent widths of H.alpha profiles [W(alpha)] and the radii of H.alpha-emitting or -absorbing envelopes (R(sub e) or R(sub a)) are nonlinearly correlated with the intrinsic continuum polarizations of these stars. However, W(alpha) and R(sub e) are linearly correlated. With large uncertainties, there is a trend of spectral dependence of polarization. Detailed discussion of these results is presented in this paper.
Bio-Inspired Sensing and Display of Polarization Imagery
2005-07-17
and weighting coefficients in this example. Panel 4D clearly shows a better visibility, feature extraction , and lesser effect from the background...of linear polarization. Panel E represents the segmentation of the degree of linear polarization, and then Panel F shows the extracted segment with...polarization, and Panel F shows the segment extraction with the finger print selected. Panel G illustrates the application of Canny edge detection to
Reid, B L
1995-06-01
The argument is developed that a structure and function already exists in selected inanimate systems for an intangible energy dissipating these systems and that, in so doing, this energy exhibits certain properties, readily recognised in the functioning biosystem. The central thesis is that, during dissipation, the structure of the biosystem affords opportunity for an enhanced display of these properties, so that this structure can be rationally recognised as obligatory in the transition, inanimate to animate matter. The systems chosen are those of reactance in linear circuit theory of electronics, and some recent developments in non-linear optics, both of which rely on imaginary or quantal force to display observable effects. Discussion occurs on the fashion which the development of a statistical formalism as a basis for the study of squeezed states of light in these non-linear systems, has, at the same time, overcome a long standing veto on the practical use of quantal energy associated with the Uncertainty Principle of Heisenberg. These ideas are used to vindicate the suggestion that a theoretical basis is presently available for an engineering type approach, toward an intangible force as it exists in the biosystem. The origins and properties of such a force continue to be considered by many as immersed in mysticism.
Simulating multiprimary LCDs on standard tri-stimulus LC displays
NASA Astrophysics Data System (ADS)
Lebowsky, Fritz; Vonneilich, Katrin; Bonse, Thomas
2008-01-01
Large-scale, direct view TV screens, in particular those based on liquid crystal technology, are beginning to use subpixel structures with more than three subpixels to implement a multi-primary display with up to six primaries. Since their input color space is likely to remain tri-stimulus RGB we first focus on some fundamental constraints. Among them, we elaborate simplified gamut mapping architectures as well as color filter geometry, transparency, and chromaticity coordinates in color space. Based on a 'display centric' RGB color space tetrahedrization combined with linear interpolation we describe a simulation framework which enables optimization for up to 7 primaries. We evaluated the performance through mapping the multi-primary design back onto a RGB LC display gamut without building a prototype multi-primary display. As long as we kept the RGB equivalent output signal within the display gamut we could analyze all desirable multi-primary configurations with regard to colorimetric variance and visually perceived quality. Not only does our simulation tool enable us to verify a novel concept it also demonstrates how carefully one needs to design a multiprimary display for LCD TV applications.
A real-time LPC-based vocal tract area display for voice development.
Rossiter, D; Howard, D M; Downes, M
1994-12-01
This article reports the design and implementation of a graphical display that presents an approximation to vocal tract area in real time for voiced vowel articulation. The acoustic signal is digitally sampled by the system. From these data a set of reflection coefficients is derived using linear predictive coding. A matrix of area coefficients is then determined that approximates the vocal tract area of the user. From this information a graphical display is then generated. The complete cycle of analysis and display is repeated at approximately 20 times/s. Synchronised audio and visual sequences can be recorded and used as dynamic targets for articulatory development. Use of the system is illustrated by diagrams of system output for spoken cardinal vowels and for vowels sung in a trained and untrained style.
A rate-controlled teleoperator task with simulated transport delays
NASA Technical Reports Server (NTRS)
Pennington, J. E.
1983-01-01
A teleoperator-system simulation was used to examine the effects of two control modes (joint-by-joint and resolved-rate), a proximity-display method, and time delays (up to 2 sec) on the control of a five-degree-of-freedom manipulator performing a probe-in-hole alignment task. Four subjects used proportional rotational control and discrete (on-off) translation control with computer-generated visual displays. The proximity display enabled subjects to separate rotational errors from displacement (translation) errors; thus, when the proximity display was used with resolved-rate control, the simulated task was trivial. The time required to perform the simulated task increased linearly with time delay, but time delays had no effect on alignment accuracy. Based on the results of this simulation, several future studies are recommended.
Eta Sigma Gamma: Preparing Leaders Today for Tomorrow's Challenges
ERIC Educational Resources Information Center
Brown, Kelli McCormack
2007-01-01
There is no one definition for a leader or for leadership, but most people can identify a leader and can provide qualities of a good leader or good leadership. The founders of Eta Gamma Gamma--William Bock, Warren Schaller, and Robert Synovitz--all displayed a critical characteristic of leadership by having and acting on a vision. Leadership has…
Circuit topology of proteins and nucleic acids.
Mashaghi, Alireza; van Wijk, Roeland J; Tans, Sander J
2014-09-02
Folded biomolecules display a bewildering structural complexity and diversity. They have therefore been analyzed in terms of generic topological features. For instance, folded proteins may be knotted, have beta-strands arranged into a Greek-key motif, or display high contact order. In this perspective, we present a method to formally describe the topology of all folded linear chains and hence provide a general classification and analysis framework for a range of biomolecules. Moreover, by identifying the fundamental rules that intrachain contacts must obey, the method establishes the topological constraints of folded linear chains. We also briefly illustrate how this circuit topology notion can be applied to study the equivalence of folded chains, the engineering of artificial RNA structures and DNA origami, the topological structure of genomes, and the role of topology in protein folding. Copyright © 2014 Elsevier Ltd. All rights reserved.
Construction of helper plasmid-mediated dual-display phage for autoantibody screening in serum.
Rajaram, Kaushik; Vermeeren, Veronique; Somers, Klaartje; Somers, Veerle; Michiels, Luc
2014-01-01
M13 filamentous bacteriophage has been used in displaying disease-specific antibodies, biomarkers, and peptides. One of the major drawbacks of using phage in diagnostic assays is the aspecific adsorption of proteins leading to a high background signal and decreasing sensitivity. To deal with this, we developed a genetically pure, exchangeable dual-display phage system in which biomarkers and streptavidin-binding protein (SBP) are displayed at opposite ends of the phage. This approach allows for sample purification, using streptavidin-coated magnetic beads resulting in a higher sensitivity of signal detection assays. Our dual-display cassette system approach also allows for easy exchange of both the anchor protein (SBP) and the displayed biomarker. The presented principle is applied for the detection of antibody reactivity against UH-RA.21 which is a good candidate biomarker for rheumatoid arthritis (RA). The applicability of dual-display phage preparation using a helper plasmid system is demonstrated, and its increased sensitivity in phage ELISA assays using patient serum samples is shown.
Thermoluminescent properties of some phosphor glasses based on aluminum oxide.
El Mesady, I; Khaled, N; Hussein, A; El Samman, H; Alawsh, S
2016-12-01
The transparent thermoluminescent aluminum oxide-based glass of 15Al 2 O 3 -35P 2 O 5 -25CaO-25Na 2 CO 3 , abbreviated as APCN (all in mol%) doped with different concentrations of SiO 2 from 0.0-500 ppm was prepared using a conventional melt-quenching technique. The TL sensitivities of the prepared glasses were investigated at 3 Gy γ-dose using a 60 Co source and measured at a heating rate 10 C/sec. The highest TL intensity of the material doped with SiO 2 was found at a concentration of 500 ppm (APCNSi 5 ). Deconvolution of the glow curve from APCNSi 5 resulted in four peaks at about 161, 194, 237 and 293 C with a Figure Of Merit (FOM) of 1.28%. The APCNSi 5 specimen had the best dosimetric properties when compared with the other samples. Reproducibility, repeatability, dose-response curve and fading effect were checked for peak 3, which appeared at about 237 C. The results displayed that the APCNSi 5 glass system was a low-Z material (Z eff ≈ 10), and had good reproducibility and good repeatability. Peak 3 showed good linearity over a dose range up to 20 Gy (R 2 = 0.999) and sublinearity behaviour was found. The signal from APCNSi 5 faded by about 11% after 2 days post irradiation, therefore it showed almost no significant loss. Such properties make the newly prepared glasses suitable for and highly recommended for use in γ-dosimeters. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Stereo 3D vision adapter using commercial DIY goods
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Ohara, Takashi
2009-10-01
The conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. Meanwhile the mirror supplies us with the same image but this mirror image is usually upside down. Assume that the images on an original screen and a virtual screen in the mirror are completely different and both images can be displayed independently. It would be possible to enlarge a screen area twice. This extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. Although the displaying region is doubled, this virtual display could not produce 3D images. In this paper, we present an extension method using a unidirectional diffusing image screen and an improvement for displaying a 3D image using orthogonal polarized image projection.
Clinical application of a modern high-definition head-mounted display in sonography.
Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa
2014-08-01
Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.
Lim, Lam Ghai; Pao, William K. S.; Hamid, Nor Hisham; Tang, Tong Boon
2016-01-01
A 360° twisted helical capacitance sensor was developed for holdup measurement in horizontal two-phase stratified flow. Instead of suppressing nonlinear response, the sensor was optimized in such a way that a ‘sine-like’ function was displayed on top of the linear function. This concept of design had been implemented and verified in both software and hardware. A good agreement was achieved between the finite element model of proposed design and the approximation model (pure sinusoidal function), with a maximum difference of ±1.2%. In addition, the design parameters of the sensor were analysed and investigated. It was found that the error in symmetry of the sinusoidal function could be minimized by adjusting the pitch of helix. The experiments of air-water and oil-water stratified flows were carried out and validated the sinusoidal relationship with a maximum difference of ±1.2% and ±1.3% for the range of water holdup from 0.15 to 0.85. The proposed design concept therefore may pose a promising alternative for the optimization of capacitance sensor design. PMID:27384567
NASA Astrophysics Data System (ADS)
Zargoosh, Kiomars; Babadi, Fatemeh Farhadian
2015-02-01
A highly sensitive and selective optical membrane for determination of Hg2+ and Pb2+ was prepared by covalent immobilization of dithizone on agarose membrane. In addition to its high stability, reproducibility and relatively long lifetime, the proposed optical sensor revealed good selectivity for target ions over a large number of alkali, alkaline earth, transition, and heavy metal ions. The proposed optical membrane displays linear responses from 1.1 × 10-8 to 2.0 × 10-6 mol L-1 and 1.2 × 10-8 to 2.4 × 10-6 mol L-1 for Hg2+ and Pb2+, respectively. The limits of detection (LOD) were 2.0 × 10-9 mol L-1 and 4.0 × 10-9 mol L-1 for Hg2+ and Pb2, respectively. The prepared optical membrane was successfully applied to the determination of Hg2+ and Pb2+ in industrial wastes, spiked tap water and natural waters without any preconcentration step.
NASA Astrophysics Data System (ADS)
Wang, Yang; Ma, Zhong-Ying; Zhang, De-Long; Deng, Jia-Li; Chen, Xiong; Xie, Cheng-Zhi; Qiao, Xin; Li, Qing-Zhong; Xu, Jing-Yuan
2018-04-01
A new aluminum ion fluorescent probe (4-(diethylamino)-2-hydroxybenzylidene)isoquinoline-1-carbohydrazide (HL1) has been conveniently synthesized and characterized. HL1 exhibited a highly selective and pronounced enhancement for Al3+ in the fluorescence emission over other common cations by forming a 2:1 complex, with a recognition mechanism based on excited-state intramolecular proton transfer (ESIPT) and intramolecular charge transfer (ICT). The strong fluorescent emission can be observed even at ppm level concentration of the probe in the presence of Al3+ with 41 fold intensity enhancement at 545 nm. HL1 displays good linear relationship with Al3+ in the low concentration and the limit of detection is 8.08 × 10-8 mol/L. Similar molecules with different substituents on salicylaldehyde phenyl ring were synthesized for studying the structure-activity relationship. Density-functional theory (DFT) calculations are in agreement with the proposed mechanism. It is confirmed that HL1 could be used to detect Al3+ ions in real sample by fluorescence spectrometry and Al3+ ions in cells by bioimaging.
Fabrication and Evaluation of a Graphene Oxide-Based Capacitive Humidity Sensor.
Feng, Jinfeng; Kang, Xiaoxu; Zuo, Qingyun; Yuan, Chao; Wang, Weijun; Zhao, Yuhang; Zhu, Limin; Lu, Hanwei; Chen, Juying
2016-03-01
In this study, a CMOS compatible capacitive humidity sensor structure was designed and fabricated on a 200 mm CMOS BEOL Line. A top Al interconnect layer was used as an electrode with a comb/serpent structure, and graphene oxide (GO) was used as sensing material. XRD analysis was done which shows that GO sensing material has a strong and sharp (002) peak at about 10.278°, whereas graphite has (002) peak at about 26°. Device level CV and IV curves were measured in mini-environments at different relative humidity (RH) level, and saturated salt solutions were used to build these mini-environments. To evaluate the potential value of GO material in humidity sensor applications, a prototype humidity sensor was designed and fabricated by integrating the sensor with a dedicated readout ASIC and display/calibration module. Measurements in different mini-environments show that the GO-based humidity sensor has higher sensitivity, faster recovery time and good linearity performance. Compared with a standard humidity sensor, the measured RH data of our prototype humidity sensor can match well that of the standard product.
Cheemalapati, Srikanth; Palanisamy, Selvakumar; Mani, Veerappan; Chen, Shen-Ming
2013-12-15
In the present study, multiwalled carbon nanotubes (MWCNT)/graphene oxide (GO) nanocomposite was prepared by homogenous dispersion of MWCNT and GO and used for the simultaneous voltammetric determination of dopamine (DA) and paracetamol (PA). The TEM results confirmed that MWCNT walls were wrapped well with GO sheets. The MWCNT/GO nanocomposite showed superior electrocatalytic activity towards the oxidation of DA and PA, when compared with either pristine MWCNT or GO. The major reason for the efficient simultaneous detection of DA and PA at nanocomposite was the synergistic effect between MWCNT and GO. The electrochemical oxidation of DA and PA was investigated by cyclic voltammetry, differential pulse voltammetry and amperometry. The nanocomposite modified electrode showed electrocatalytic oxidation of DA and PA in the linear response range from 0.2 to 400 µmol L(-1) and 0.5 to 400 µmol L(-1) with the detection limit of 22 nmol L(-1) and 47 nmol L(-1) respectively. The proposed sensor displayed good selectivity, sensitivity, stability with appreciable consistency and precision. © 2013 Elsevier B.V. All rights reserved.
Vollebregt, Sten; Ishihara, Ryoichi
2015-01-01
We demonstrate a method for the low temperature growth (350 °C) of vertically-aligned carbon nanotubes (CNT) bundles on electrically conductive thin-films. Due to the low growth temperature, the process allows integration with modern low-κ dielectrics and some flexible substrates. The process is compatible with standard semiconductor fabrication, and a method for the fabrication of electrical 4-point probe test structures for vertical interconnect test structures is presented. Using scanning electron microscopy the morphology of the CNT bundles is investigated, which demonstrates vertical alignment of the CNT and can be used to tune the CNT growth time. With Raman spectroscopy the crystallinity of the CNT is investigated. It was found that the CNT have many defects, due to the low growth temperature. The electrical current-voltage measurements of the test vertical interconnects displays a linear response, indicating good ohmic contact was achieved between the CNT bundle and the top and bottom metal electrodes. The obtained resistivities of the CNT bundle are among the average values in the literature, while a record-low CNT growth temperature was used. PMID:26709530
Yang, Xiupei; Yuan, Hongyan; Wang, Chunling; Su, Xiaodong; Hu, Li; Xiao, Dan
2007-10-18
In this paper, a capillary electrophoresis (CE) system with in-column fiber optics light-emitting diode (LED) induced fluorescence detection was developed for the determination of penicillamine (PA). The influence of buffer concentration, buffer pH, applied voltage and injection time was systematically investigated. Optimum separation conditions were obtained with 10 mM borate buffer at pH 9.1, applied voltage 20 kV and 8 s hydrodynamic injection at 30 mbar. The detection system displayed linear dynamic range from 3.2 x 10(-7) to 4.8 x 10(-5) mol L(-1) with a correlation coefficient of 0.9991 and good repeatability (R.S.D.=2.46%). The method was applied to the determination of PA in commercial tablets and human plasma, which the recoveries of standard PA added to tablets and human plasma sample were found to be in the range of 96.26-102.68 and 91.10-99.35%, respectively. The proposed method is cheap, rapid, easy, and accurate, and can be successfully applied to the formulation analysis and bioanalysis.
Design and performance of a custom ASIC digitizer for wire chamber readout in 65 nm CMOS technology
NASA Astrophysics Data System (ADS)
Lee, M. J.; Brown, D. N.; Chang, J. K.; Ding, D.; Gnani, D.; Grace, C. R.; Jones, J. A.; Kolomensky, Y. G.; von der Lippe, H.; Mcvittie, P. J.; Stettler, M. W.; Walder, J.-P.
2015-06-01
We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital Converters (TDCs), one 8-bit Analog-to-Digital Converter (ADC), a front-end preamplifier and shaper, plus digital and analog buffers that support a variety of digitization chains. The prototype has a multiplexed digital backend that executes a state machine, distributes control and timing signals, and buffers data for serial output. Laboratory bench tests measure the absolute TDC resolution between 74 ps and 480 ps, growing with the absolute delay, and a relative time resolution of 19 ps. Resolution outliers due to cross-talk between clock signals and supply or reference voltages are seen. After calibration, the ADC displays good linearity and noise performance, with an effective number of bits of 6.9. Under normal operating conditions the circuit consumes 32 mW per channel. Potential design improvements to address the resolution drift and tails are discussed.
Spin dynamics and exchange interactions in CuO measured by neutron scattering
NASA Astrophysics Data System (ADS)
Jacobsen, H.; Gaw, S. M.; Princep, A. J.; Hamilton, E.; Tóth, S.; Ewings, R. A.; Enderle, M.; Wheeler, E. M. Hétroy; Prabhakaran, D.; Boothroyd, A. T.
2018-04-01
The magnetic properties of CuO encompass several contemporary themes in condensed-matter physics, including quantum magnetism, magnetic frustration, magnetically-induced ferroelectricity, and orbital currents. Here we report polarized and unpolarized neutron inelastic scattering measurements which provide a comprehensive map of the cooperative spin dynamics in the low-temperature antiferromagnetic (AFM) phase of CuO throughout much of the Brillouin zone. At high energies (E ≳100 meV ), the spectrum displays continuum features consistent with the des Cloizeax-Pearson dispersion for an ideal S =1/2 Heisenberg AFM chain. At lower energies, the spectrum becomes more three dimensional, and we find that a linear spin-wave model for a Heisenberg AFM provides a very good description of the data, allowing for an accurate determination of the relevant exchange constants in an effective spin Hamiltonian for CuO. In the high-temperature helicoidal phase, there are features in the measured low-energy spectrum that we could not reproduce with a spin-only model. We discuss how these might be associated with the magnetically-induced multiferroic behavior observed in this phase.
NASA Astrophysics Data System (ADS)
Deng, Yanan; Chang, Quanying; Yin, Kai; Liu, Chengbin; Wang, Ying
2017-10-01
A highly stable and effective electrochemiluminescence (ECL) sensing system of cadmium sulfide nanowires/reduced graphene oxide (CdS NWS/rGO) hybrid is presented for supersensitive detection of pentachlorophenol (PCP). CdS nanowire is for the first time exploited in ECL sensing. The rGO served as both ECL signal amplifier and immobilization platform, can perfectly enhance the ECL intensity and stability of the sensing system. With S2O82- as coreactant, the ECL signal can be significantly quenched by the addition of PCP. The established ECL sensing system presents a wider linear range from 1.0 × 10-14 to 1.0 × 10-8 M and a much low detection limit of 2 × 10-15 M under the optimum test conditions (e.g., pH 7.0 and 100 mM S2O82-). Furthermore, the ECL sensing system displays a good selectivity for PCP detection. The practicability of the ECL sensing system in real water sample shows that this system could be promisingly applied in the analytical detection of PCP in real water environments.
NASA Astrophysics Data System (ADS)
Yang, Xiao-Yong; Lu, Yong; Zheng, Fa-Wei; Zhang, Ping
2015-11-01
Mechanical, electronic, and thermodynamic properties of zirconium carbide have been systematically studied using the ab initio calculations. The calculated equilibrium lattice parameter, bulk modulus, and elastic constants are all well consistent with the experimental data. The electronic band structure indicates that the mixture of C 2p and Zr 4d and 4p orbitals around the Fermi level makes a large covalent contribution to the chemical bonds between the C and Zr atoms. The Bader charge analysis suggests that there are about 1.71 electrons transferred from each Zr atom to its nearest C atom. Therefore, the Zr-C bond displays a mixed ionic/covalent character. The calculated phonon dispersions of ZrC are stable, coinciding with the experimental measurement. A drastic expansion in the volume of ZrC is seen with increasing temperature, while the bulk modulus decreases linearly. Based on the calculated phonon dispersion curves and within the quasi-harmonic approximation, the temperature dependence of the heat capacities is obtained, which gives a good description compared with the available experimental data. Project supported by the National Natural Science Foundation of China (Grant No. 51071032).
High selectivity of colorimetric detection of p-nitrophenol based on Ag nanoclusters
NASA Astrophysics Data System (ADS)
Qu, Fei; Chen, Ping; Zhu, Shuyun; You, Jinmao
2017-01-01
Ag nanoclusters (Ag NCs) templated by hyperbranched polyethyleneimine (PEI) with different terminal groups and molecular weights had been developed as a special optical sensor for detecting p-nitrophenol (p-NP). When adding p-NP into Ag NCs, an obvious color change from pale yellow to deep yellow could be observed by naked eyes, accompanying with an apparent red-shift of absorption peak, and the reason was attributed to the formation of oxygen anion of p-NP based on the transfer of H+ from p-NP to amine groups of PEI. The molecular weights of template would greatly affect the sensitivity of p-NP. Ag NCs capped by PEI terminated ethylenediamine (EDA) possessed better sensitivity than other Ag NCs, showing good linear range from 5 to 140 μM with the limit of detection as low as 1.28 μM. Most importantly, this present system displayed high selectivity toward p-NP even in the presence of other nitrophenols and nitrotoluenes. This reliable method had been successfully applied for the detection of p-NP in real water and soil samples.
Dilgin, Didem Giray; Karakaya, Serkan
2016-06-01
In this study, a new selective and sensitive voltammetric procedure for determination of acyclovir (ACV) was proposed using a disposable electrode, pencil graphite electrode (PGE). Cyclic and differential pulse voltammograms of ACV were recorded in Britton-Robinson buffer solution containing 0.10 M KCl with pH of 4.0 at PGE. The PGE displayed a very good electrochemical behavior with significant enhancement of the peak current compared to a glassy carbon electrode (GCE). Under experimental conditions, the PGE had a linear response range from 1.0 μM to 100.0 μM ACV with a detection limit of 0.3 μM (based on 3 Sb). Relative standard deviations of 4.8 and 3.6% were obtained for five successive determinations of 10.0 and 50.0 μM ACV, respectively, which indicate acceptable repeatability. This voltammetric method was successfully applied to the direct determination of ACV in real pharmaceutical samples. The effect of various interfering compounds on the ACV peak current was studied. Copyright © 2016 Elsevier B.V. All rights reserved.
Plasmonic detection of mercury via amalgam formation on surface-immobilized single Au nanorods
NASA Astrophysics Data System (ADS)
Schopf, Carola; Martín, Alfonso; Iacopino, Daniela
2017-12-01
Au nanorods were used as plasmonic transducers for investigation of mercury detection through a mechanism of amalgam formation at the nanorod surfaces. Marked scattering color transitions and associated blue shifts of the surface plasmon resonance peak wavelengths (λmax) were measured in individual nanorods by darkfield microscopy upon chemical reduction of Hg(II). Such changes were related to compositional changes occurring as a result of Hg-Au amalgam formation as well as morphological changes in the nanorods' aspect ratios. The plot of λmax shifts vs. Hg(II) concentration showed a linear response in the 10-100 nM concentration range. The sensitivity of the system was ascribed to the narrow width of single nanorod scattering spectra, which allowed accurate determination of peak shifts. The system displayed good selectivity as the optical response obtained for mercury was one order of magnitude higher than the response obtained with competitor ions. Analysis of mercury content in river and tap water were also performed and highlighted both the potential and limitation of the developed method for real sensing applications.
NASA Technical Reports Server (NTRS)
Axholt, Magnus; Skoglund, Martin; Peterson, Stephen D.; Cooper, Matthew D.; Schoen, Thomas B.; Gustafsson, Fredrik; Ynnerman, Anders; Ellis, Stephen R.
2010-01-01
Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.
Niyazi, Maximilian; Adeberg, Sebastian; Kaul, David; Boulesteix, Anne-Laure; Bougatf, Nina; Fleischmann, Daniel F; Grün, Arne; Krämer, Anna; Rödel, Claus; Eckert, Franziska; Paulsen, Frank; Kessel, Kerstin A; Combs, Stephanie E; Oehlke, Oliver; Grosu, Anca-Ligia; Seidlitz, Annekatrin; Lattermann, Annika; Krause, Mechthild; Baumann, Michael; Guberina, Maja; Stuschke, Martin; Budach, Volker; Belka, Claus; Debus, Jürgen
2018-04-01
Reirradiation (reRT) is a valid option with considerable efficacy in patients with recurrent high-grade glioma, but it is still not known which patients might be optimal candidates for a second course of irradiation. This study validated a newly developed prognostic score independently in an external patient cohort. The reRT risk score (RRRS) is based on a linear combination of initial histology, clinical performance status, and age derived from a multivariable model of 353 patients. This score can predict post-recurrence survival (PRS) after reRT. The validation dataset consisted of 212 patients. The RRRS differentiates three prognostic groups. Discrimination and calibration were maintained in the validation group. Median PRS times in the development cohort for the good/intermediate/poor risk categories were 14.2, 9.1, and 5.3 months, respectively. The respective groups within the validation cohort displayed median PRS times of 13.8, 8.8, and 3.8 months, respectively. Uno's C for development data was 0.64 (CI: 0.60-0.69) and for validation data 0.63 (CI: 0.58-0.68). The RRRS has been successfully validated in an independent patient cohort. This linear combination of three easily determined clinicopathological factors allows for a reliable classification of patients and may be used as stratification factor for future trials. Copyright © 2018 Elsevier B.V. All rights reserved.
Luminescent molecular rods - transition-metal alkynyl complexes.
Yam, Vivian Wing-Wah; Wong, Keith Man-Chung
2005-01-01
A number of transition-metal complexes have been reported to exhibit rich luminescence, usually originating from phosphorescence. Such luminescence properties of the triplet excited state with a large Stoke's shift, long lifetime, high luminescence quantum yield as well as lower excitation energy, are envisaged to serve as an ideal candidate in the area of potential applications for chemosensors, dye-sensitized solar cells, flat panel displays, optics, new materials and biological sciences. Organic alkynes (poly-ynes), with extended or conjugatedπ-systems and rigid structure with linear geometry, have become a significant research area due to their novel electronic and physical properties and their potential applications in nanotechnology. Owing to the presence of unsaturated sp-hybridized carbon atoms, the alkynyl unit can serve as a versatile building block in the construction of alkynyl transition-metal complexes, not only throughσ-bonding but also viaπ-bonding interactions. By incorporation of linear alkynyl groups into luminescent transition-metal complexes, the alkynyl moiety with goodσ-donor,π-donor andπ-acceptor abilities is envisaged to tune or perturb the emission behaviors, including emission energy (color), intensity and lifetime by its role as an auxiliary ligand as well as to govern the emission origin from its direct involvement. This review summarizes recent efforts on the synthesis of luminescent rod-like alkynyl complexes with different classes of transition metals and details the effects of the introduction of alkynyl groups on the luminescence properties of the complexes.
Surface wave tomography of Europe from ambient seismic noise
NASA Astrophysics Data System (ADS)
Lu, Yang; Stehly, Laurent; Paul, Anne
2017-04-01
We present a European scale high-resolution 3-D shear wave velocity model derived from ambient seismic noise tomography. In this study, we collect 4 years of continuous seismic recordings from 1293 stations across much of the European region (10˚W-35˚E, 30˚N-75˚N), which yields more than 0.8 million virtual station pairs. This data set compiles records from 67 seismic networks, both permanent and temporary from the EIDA (European Integrated Data Archive). Rayleigh wave group velocity are measured at each station pair using the multiple-filter analysis technique. Group velocity maps are estimated through a linearized tomographic inversion algorithm at period from 5s to 100s. Adaptive parameterization is used to accommodate heterogeneity in data coverage. We then apply a two-step data-driven inversion method to obtain the shear wave velocity model. The two steps refer to a Monte Carlo inversion to build the starting model, followed by a linearized inversion for further improvement. Finally, Moho depth (and its uncertainty) are determined over most of our study region by identifying and analysing sharp velocity discontinuities (and sharpness). The resulting velocity model shows good agreement with main geological features and previous geophyical studies. Moho depth coincides well with that obtained from active seismic experiments. A focus on the Greater Alpine region (covered by the AlpArray seismic network) displays a clear crustal thinning that follows the arcuate shape of the Alps from the southern French Massif Central to southern Germany.
Wei, Yanfen; Wang, Hao; Sun, Shuangjiao; Tang, Lifu; Cao, Yupin; Deng, Biyang
2016-12-15
A new electrochemiluminescence (ECL) sensor based on reduced graphene oxide-copper sulfide (rGO-CuS) composite coupled with capillary electrophoresis (CE) was constructed for the ultrasensitive detection of amlodipine besylate (AML) for the first time. In this work, rGO-CuS composite was synthesized by one-pot hydrothermal method and used for electrode modification. The electrochemical and ECL behaviors of the sensor were investigated. More than 5-fold enhance in ECL intensity was observed after modified with rGO-CuS composite. The results can be ascribed to the presence of rGO-CuS composite on the electrode surface that facilitates the electron transfer rate between the electroactive center of Ru(bpy)3(2+) and the electrode. The ECL sensor was coupled with CE to improve the selectivity and the CE-ECL parameters that affect separation and detection were optimized. Under the optimum conditions, the linear ranges for AML was 0.008-5.0μg/mL with a detection limit of 2.8ng/mL (S/N=3). The method displayed the advantages of high sensitivity, good selectivity, wide linear range, low detection limit and fine reproducibility, and was used to analyze AML in mice plasma with a satisfactory result, which holds a great potential in the field of pharmaceutical analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Luminescent screen composition and apparatus
NASA Technical Reports Server (NTRS)
Hilborn, E. H.
1970-01-01
Ultraviolet light projects photographically produced images on a screen composed of a mixture of linear and nonlinear phosphors whose spectral emissions are different. This allows the display of polychromatic luminescent images, which gives better discrimination of the objects being viewed.
Sreenilayam, Sithara P.; Panarin, Yuri P.; Vij, Jagdish K.; Panov, Vitaly P.; Lehmann, Anne; Poppe, Marco; Prehm, Marko; Tschierske, Carsten
2016-01-01
Liquid crystals (LCs) represent one of the foundations of modern communication and photonic technologies. Present display technologies are based mainly on nematic LCs, which suffer from limited response time for use in active colour sequential displays and limited image grey scale. Herein we report the first observation of a spontaneously formed helix in a polar tilted smectic LC phase (SmC phase) of achiral bent-core (BC) molecules with the axis of helix lying parallel to the layer normal and a pitch much shorter than the optical wavelength. This new phase shows fast (∼30 μs) grey-scale switching due to the deformation of the helix by the electric field. Even more importantly, defect-free alignment is easily achieved for the first time for a BC mesogen, thus providing potential use in large-scale devices with fast linear and thresholdless electro-optical response. PMID:27156514
The role of nonlinear viscoelasticity on the functionality of laminating shortenings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macias-Rodriguez, Braulio A.; Peyronel, Fernanda; Marangoni, Alejandro G.
The rheology of fats is essential for the development of homogeneous and continuous layered structures of doughs. Here, we define laminating shortenings in terms of rheological behavior displayed during linear-to-nonlinear shear deformations, investigated by large amplitude oscillatory shear rheology. Likewise, we associate the rheological behavior of the shortenings with structural length scales elucidated by ultra-small angle x-ray scattering and cryo-electron microscopy. Shortenings exhibited solid-like viscoelastic and viscoelastoplastic behaviors in the linear and nonlinear regimes respectively. In the nonlinear region, laminating shortenings dissipated more viscous energy (larger normalized dynamic viscosities) than a cake bakery shortening. The fat solid-like network of laminatingmore » shortening displayed a three-hierarchy structure and layered crystal aggregates, in comparison to two-hierarchy structure and spherical-like crystal aggregates of a cake shortening. We argue that the observed rheology, correlated to the structural network, is crucial for optimal laminating performance of shortenings.« less
NASA Astrophysics Data System (ADS)
Sreenilayam, Sithara P.; Panarin, Yuri P.; Vij, Jagdish K.; Panov, Vitaly P.; Lehmann, Anne; Poppe, Marco; Prehm, Marko; Tschierske, Carsten
2016-05-01
Liquid crystals (LCs) represent one of the foundations of modern communication and photonic technologies. Present display technologies are based mainly on nematic LCs, which suffer from limited response time for use in active colour sequential displays and limited image grey scale. Herein we report the first observation of a spontaneously formed helix in a polar tilted smectic LC phase (SmC phase) of achiral bent-core (BC) molecules with the axis of helix lying parallel to the layer normal and a pitch much shorter than the optical wavelength. This new phase shows fast (~30 μs) grey-scale switching due to the deformation of the helix by the electric field. Even more importantly, defect-free alignment is easily achieved for the first time for a BC mesogen, thus providing potential use in large-scale devices with fast linear and thresholdless electro-optical response.
Photonic band gap structure simulator
Chen, Chiping; Shapiro, Michael A.; Smirnova, Evgenya I.; Temkin, Richard J.; Sirigiri, Jagadishwar R.
2006-10-03
A system and method for designing photonic band gap structures. The system and method provide a user with the capability to produce a model of a two-dimensional array of conductors corresponding to a unit cell. The model involves a linear equation. Boundary conditions representative of conditions at the boundary of the unit cell are applied to a solution of the Helmholtz equation defined for the unit cell. The linear equation can be approximated by a Hermitian matrix. An eigenvalue of the Helmholtz equation is calculated. One computation approach involves calculating finite differences. The model can include a symmetry element, such as a center of inversion, a rotation axis, and a mirror plane. A graphical user interface is provided for the user's convenience. A display is provided to display to a user the calculated eigenvalue, corresponding to a photonic energy level in the Brilloin zone of the unit cell.
Design and synthesis of N-(4-aminopyridin-2-yl)amides as B-Raf(V600E) inhibitors.
Li, Xiaokai; Shen, Jiayi; Tan, Li; Zhang, Zhang; Gao, Donglin; Luo, Jinfeng; Cheng, Huimin; Zhou, Xiaoping; Ma, Jie; Ding, Ke; Lu, Xiaoyun
2016-06-15
B-Raf(V600E) was an effective target for the treatment of human cancers. Based on a pan-Raf inhibitor TAK-632, a series of N-(4-aminopyridin-2-yl)amide derivatives were designed as novel B-Raf(V600E) inhibitors. Detailed structure-activity studies of the compounds revealed that most of the compounds displayed potent enzymatic activity against B-Raf(V600E), and good selectivity over B-Raf(WT). One of the most promising compound 4l exhibited potent inhibitory activity with an IC50 value of 38nM for B-raf(V600E), and displayed antiproliferative activities against colo205 and HT29 cells with IC50 values of 0.136 and 0.094μM, respectively. It also displayed good selectivity on both enzymatic and cellular assays over B-Raf(WT). These inhibitors may serve as lead compounds for further developing novel B-Raf(V600E) inhibitors as anticancer drugs. Copyright © 2016 Elsevier Ltd. All rights reserved.
A rapid method for determining salinomycin and monensin sensitivity in Eimeria tenella.
Jenkins, M C; O'Brien, C N; Fuller, L; Mathis, G F; Fetterer, R
2014-12-15
Standard methods of determining the ionophore sensitivity of Eimeria rely on infecting chickens with an isolate or a mixture of Eimeria spp. oocysts in the presence of different anti-coccidial drugs. The purpose of this study was to develop a rapid in vitro method for assessing salinomycin and monensin sensitivity in Eimeria tenella. Cultures of MDBK cells were grown to 85% confluency, and then inoculated with excysted E. tenella laboratory strain (APU-1) sporozoites in the presence of different concentrations of salinomycin or monensin. At various timepoints, the monolayers were fixed for counting intraceullar sporozoites, or were subjected to DNA extraction, followed by molecular analysis using quantitative (qPCR) or semi-quantitative PCR (sqPCR). Preliminary experiments showed that 24h was the optimum time for harvesting the E. tenella-infected cell cultures. The average number of E. tenella sporozoites relative to untreated controls displayed a linear decrease between 0.3 and 33.0 μg/ml salinomycin and between 0.3 and 3.3 μg/ml monensin. A similar pattern was observed in the relative amount of E. tenella DNA as measured by sqPCR. A linear decrease in the relative amount of E. tenella DNA was observed over the entire range of salinomycin and monensin concentrations as measured by qPCR possibly reflecting the greater sensitivity of this assay. Comparison of sporozoite counting, sqPCR, and qPCR signals using a criterion of 50% inhibition in sporozoite numbers or level of PCR amplification product showed good agreement between the three assays. E. tenella field isolates (FS-1 and FS-2) displaying resistance to salinomycin and monensin were evaluated in the in vitro assay using qPCR and sqPCR. Compared to E. tenella APU-1, the E. tenella FS-1 and FS-2 isolates showed higher levels of E. tenella DNA at 24h by both qPCR and sqPCR. This in vitro assay represents a significant advance in developing rapid, cost-effective methods for assessing ionophore sensitivity in E. tenella. Published by Elsevier B.V.
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1998-01-01
A method for generating a validated measurement of a process parameter at a point in time by using a plurality of individual sensor inputs from a scan of said sensors at said point in time. The sensor inputs from said scan are stored and a first validation pass is initiated by computing an initial average of all stored sensor inputs. Each sensor input is deviation checked by comparing each input including a preset tolerance against the initial average input. If the first deviation check is unsatisfactory, the sensor which produced the unsatisfactory input is flagged as suspect. It is then determined whether at least two of the inputs have not been flagged as suspect and are therefore considered good inputs. If two or more inputs are good, a second validation pass is initiated by computing a second average of all the good sensor inputs, and deviation checking the good inputs by comparing each good input including a present tolerance against the second average. If the second deviation check is satisfactory, the second average is displayed as the validated measurement and the suspect sensor as flagged as bad. A validation fault occurs if at least two inputs are not considered good, or if the second deviation check is not satisfactory. In the latter situation the inputs from each of all the sensors are compared against the last validated measurement and the value from the sensor input that deviates the least from the last valid measurement is displayed.
Psychophysical contrast calibration
To, Long; Woods, Russell L; Goldstein, Robert B; Peli, Eli
2013-01-01
Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical responses of a person with normal vision to calibrate the luminance contrast of displays for experimental and clinical applications. Our method combines psychophysical techniques (1) for detection (and thus elimination or reduction) of display saturating nonlinearities; (2) for luminance (gamma function) estimation and linearization without use of a photometer; and (3) to measure without a photometer the luminance ratios of the display’s three color channels that are used in a bit-stealing procedure to expand the luminance resolution of the display. Using a photometer we verified that the calibration achieved with this procedure is accurate for both LCD and CRT displays enabling testing of letter contrast sensitivity to 0.5%. Our visual calibration procedure enables clinical, internet and home implementation and calibration verification of electronic contrast testing. PMID:23643843
Bringing text display digital radio to consumers with hearing loss.
Sheffield, Ellyn G; Starling, Michael; Schwab, Daniel
2011-01-01
Radio is migrating to digital transmission, expanding its offerings to include captioning for individuals with hearing loss. Text display radio requires a large amount of word throughput with minimal screen display area, making good user interface design crucial to its success. In two experiments, we presented hearing, hard-of-hearing, and deaf consumers with National Public Radio stories converted to text and examined their preferences for and reactions to midsized and small radio text displays. We focused on physical display attributes such as text color, font style, line length, and scrolling type as well as emergency alert messages and emergency prompts for drivers, announcer identification schemes, and synchronization of audio and text. Results suggest that midsized, Global Positioning System (GPS)-style displays were well liked, synchronization of audio and text was important to comprehension and retrieval of story details, identification of announcers was served best with a combination of name change in parenthesis and color change, and a mixture of color and flashing symbols was preferred for emergency alerting.
Linear Quantum Systems: Non-Classical States and Robust Stability
2016-06-29
has a history going back some 50 years, to the birth of modern control theory with Kalman’s foundational work on filtering and LQG optimal control ...information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD...analysis and control of quantum linear systems and their interactions with non-classical quantum fields by developing control theoretic concepts exploiting
On Asymptotically Good Ramp Secret Sharing Schemes
NASA Astrophysics Data System (ADS)
Geil, Olav; Martin, Stefano; Martínez-Peñas, Umberto; Matsumoto, Ryutaroh; Ruano, Diego
Asymptotically good sequences of linear ramp secret sharing schemes have been intensively studied by Cramer et al. in terms of sequences of pairs of nested algebraic geometric codes. In those works the focus is on full privacy and full reconstruction. In this paper we analyze additional parameters describing the asymptotic behavior of partial information leakage and possibly also partial reconstruction giving a more complete picture of the access structure for sequences of linear ramp secret sharing schemes. Our study involves a detailed treatment of the (relative) generalized Hamming weights of the considered codes.
The Statistics of Visual Representation
NASA Technical Reports Server (NTRS)
Jobson, Daniel J.; Rahman, Zia-Ur; Woodell, Glenn A.
2002-01-01
The experience of retinex image processing has prompted us to reconsider fundamental aspects of imaging and image processing. Foremost is the idea that a good visual representation requires a non-linear transformation of the recorded (approximately linear) image data. Further, this transformation appears to converge on a specific distribution. Here we investigate the connection between numerical and visual phenomena. Specifically the questions explored are: (1) Is there a well-defined consistent statistical character associated with good visual representations? (2) Does there exist an ideal visual image? And (3) what are its statistical properties?
Mayr, Susanne; Buchner, Axel
2010-07-01
Participants performed a word-non-word discrimination task within a car control display emulated on a thin film transistor liquid-crystal display (TFT-LCD). The task simulated an information read-out from a TFT-LCD-based instrument panel. Subsequently, participants performed a low-contrast object detection task that simulated the detection of objects during night-time driving. In experiment 1, words/non-words were presented black-on-white (positive polarity) or white-on-black (negative polarity). In experiments 2 and 3, display colour was additionally manipulated. A positive polarity advantage in the discrimination task was consistently observed. In contrast, positive displays interfered more than negative displays with subsequent detection. The detrimental after-effect of positive polarity displays was strong with white and blue, reduced with amber and absent with red displays. Subjective measures showed a preference for blue over red, but a slight advantage for amber over blue. Implications for TFT-LCD design are derived from the results. STATEMENT OF RELEVANCE: When using TFT-LCDs as car instrument panels, positive polarity red TFT-LCDs are very likely to lead to good instrument readability while at the same time minimising - relative to other colours - the negative effects of an illuminated display on low-contrast object detection during night-time driving.
Tang, Wenwei; Li, Lei; Wu, Lujun; Gong, Jiemin; Zeng, Xinping
2014-01-01
A novel glucose biosensor was fabricated. The first layer of the biosensor was polythionine, which was formed by the electrochemical polymerisation of the thionine monomer on a glassy carbon electrode. The remaining layers were coated with chitosan-MWCNTs, GOx, and the chitosan-PTFE film in sequence. The MWCNTs embedded in FAD were like “conductive wires” connecting FAD with electrode, reduced the distance between them and were propitious to fast direct electron transfer. Combining with good electrical conductivity of PTH and MWCNTs, the current response was enlarged. The sensor was a parallel multi-component reaction system (PMRS) and excellent electrocatalytic performance for glucose could be obtained without a mediator. The glucose sensor had a working voltage of −0.42 V, an optimum working temperature of 25°C, an optimum working pH of 7.0, and the best percentage of polytetrafluoroethylene emulsion (PTFE) in the outer composite film was 2%. Under the optimised conditions, the biosensor displayed a high sensitivity of 2.80 µA mM−1 cm−2 and a low detection limit of 5 µM (S/N = 3), with a response time of less than 15 s and a linear range of 0.04 mM to 2.5 mM. Furthermore, the fabricated biosensor had a good selectivity, reproducibility, and long-term stability, indicating that the novel CTS+PTFE/GOx/MWCNTs/PTH composite is a promising material for immobilization of biomolecules and fabrication of third generation biosensors. PMID:24816121
Tang, Wenwei; Li, Lei; Wu, Lujun; Gong, Jiemin; Zeng, Xinping
2014-01-01
A novel glucose biosensor was fabricated. The first layer of the biosensor was polythionine, which was formed by the electrochemical polymerisation of the thionine monomer on a glassy carbon electrode. The remaining layers were coated with chitosan-MWCNTs, GOx, and the chitosan-PTFE film in sequence. The MWCNTs embedded in FAD were like "conductive wires" connecting FAD with electrode, reduced the distance between them and were propitious to fast direct electron transfer. Combining with good electrical conductivity of PTH and MWCNTs, the current response was enlarged. The sensor was a parallel multi-component reaction system (PMRS) and excellent electrocatalytic performance for glucose could be obtained without a mediator. The glucose sensor had a working voltage of -0.42 V, an optimum working temperature of 25°C, an optimum working pH of 7.0, and the best percentage of polytetrafluoroethylene emulsion (PTFE) in the outer composite film was 2%. Under the optimised conditions, the biosensor displayed a high sensitivity of 2.80 µA mM(-1) cm(-2) and a low detection limit of 5 µM (S/N = 3), with a response time of less than 15 s and a linear range of 0.04 mM to 2.5 mM. Furthermore, the fabricated biosensor had a good selectivity, reproducibility, and long-term stability, indicating that the novel CTS+PTFE/GOx/MWCNTs/PTH composite is a promising material for immobilization of biomolecules and fabrication of third generation biosensors.
Adediran, S A; Ratkowsky, D A; Donaghy, D J; Malau-Aduli, A E O
2012-09-01
Fourteen lactation models were fitted to average and individual cow lactation data from pasture-based dairy systems in the Australian states of Victoria and Tasmania. The models included a new "log-quadratic" model, and a major objective was to evaluate and compare the performance of this model with the other models. Nine empirical and 5 mechanistic models were first fitted to average test-day milk yield of Holstein-Friesian dairy cows using the nonlinear procedure in SAS. Two additional semiparametric models were fitted using a linear model in ASReml. To investigate the influence of days to first test-day and the number of test-days, 5 of the best-fitting models were then fitted to individual cow lactation data. Model goodness of fit was evaluated using criteria such as the residual mean square, the distribution of residuals, the correlation between actual and predicted values, and the Wald-Wolfowitz runs test. Goodness of fit was similar in all but one of the models in terms of fitting average lactation but they differed in their ability to predict individual lactations. In particular, the widely used incomplete gamma model most displayed this failing. The new log-quadratic model was robust in fitting average and individual lactations, and was less affected by sampled data and more parsimonious in having only 3 parameters, each of which lends itself to biological interpretation. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Shi, Chunli; Guo, Xing; Qu, Qianqian; Tang, Zhaomin; Wang, Yi; Zhou, Shaobing
2014-10-01
In cancer therapy nanocargos based on star-shaped polymer exhibit unique features such as better stability, smaller size distribution and higher drug capacity in comparison to linear polymeric micelles. In this study, we developed a multifunctional star-shaped micellar system by combination of active targeting ability and redox-responsive behavior. The star-shaped micelles with good stability were self-assembled from four-arm poly(ε-caprolactone)-poly(ethylene glycol) copolymer. The redox-responsive behaviors of these micelles triggered by glutathione were evaluated from the changes of micellar size, morphology and molecular weight. In vitro drug release profiles exhibited that in a stimulated normal physiological environment, the redox-responsive star-shaped micelles could maintain good stability, whereas in a reducing and acid environment similar with that of tumor cells, the encapsulated agent was promptly released. In vitro cellular uptake and subcellular localization of these micelles were further studied with confocal laser scanning microscopy and flow cytometry against the human cervical cancer cell line HeLa. In vivo and ex vivo DOX fluorescence imaging displayed that these FA-functionalized star-shaped micelles possessed much better specificity to target solid tumor. Both the qualitative and quantitative results of the antitumor effect in 4T1 tumor-bearing BALB/c mice demonstrated that these redox-responsive star-shaped micelles have a high therapeutic efficiency to artificial solid tumor. Therefore, the multifunctional star-shaped micelles are a potential platform for targeted anticancer drug delivery. Copyright © 2014 Elsevier Ltd. All rights reserved.
Measurement of luminance and color uniformity of displays using the large-format scanner
NASA Astrophysics Data System (ADS)
Mazikowski, Adam
2017-08-01
Uniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce satisfactory results, so a different solution is proposed in the paper. The developed system consists of the large-format X-Y-Z ISEL scanner (isel Germany AG), Konica Minolta high sensitivity spot photometer-colorimeter (e.g. CS-200, Konica Minolta, Inc.) and PC computer. Dedicated software in LabView environment for control of the scanner, transfer the measured data to the computer, and visualization of measurement results was also prepared. Based on the developed setup measurements of plasma display and LCD-LED display were performed. A heavily wornout plasma TV unit, with several artifacts visible was selected. These tests show the advantages and drawbacks of described scanning method with comparison with 9-point simplified uniformity determining method.
Chan, Alan H S; Hoffmann, Errol R
2015-01-01
Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.
Li, Tao; Wang, Gaoling; Shi, Bingtian; Liu, Peixin; Si, Wei; Wang, Bin; Jiang, Li; Zhou, Lunjiang; Xiu, Jinsheng; Liu, Henggui
2015-01-01
Circulation of genotype VII Newcastle disease virus (NDV) has posed a great threat for the poultry industry worldwide. Antibodies against Hemagglutinin-neuraminidase (HN), a membrane protein of NDV with critical roles in NDV infection, have been reported to provide chickens protection from NDV infection. In this study, we comprehensively analyzed the in vivo antibody responses against the linear antigenic domains of the HN protein from genotype VII NDV using a yeast surface display system. The results revealed four distinct regions of HN, P1 (1-52aa), P2 (53-192aa), P3 (193-302aa) and P4 (303-571aa), respectively, according to their antigenic potency. Analysis by FACS and ELISA assay indicated P2 to be the dominant linear antigenic domain, with the immunogenic potency to protect the majority of chickens from NDV challenge. In contrast, the P1, P3 and P4 domains showed weak antigenicity in vivo and could not protect chickens from NDV challenge. These results provide important insight into the characteristic of humoral immune responses elicited by HN of NDV in vivo. PMID:26121247
Chow, Daniel S; Ha, Richard; Filippi, Christopher G
2015-01-01
OBJECTIVE; There is evidence in academic medicine that the number of authors per paper has increased over time. The goal of this study was to quantitatively analyze authorship trends in the field of radiology over 20 years. A search of the National Library of Medicine MEDLINE database was conducted to identify articles published by radiology departments between 1991 and 2012. Country of origin, article study design, and journal impact factor were recorded. The increase in number of authors per paper was assessed by linear and nonlinear regression. Pearson correlation was used to assess the relation between journal impact factor and number of authors. A total of 142,576 articles and 699,257 authors were identified during the study period. The mean number of authors per paper displayed linear growth from 3.9 to 5.7 (p < 0.0001). The proportion of single authors declined from 11% in 1991 to 4.4% in 2012. The number of clinical trials increased in a linear pattern, review articles in an exponential pattern, and case reports in a logistic pattern (p < 0.0001 for each). Countries with the highest number of authors per paper were Japan, Italy, and Germany. The number of articles funded by the U.S. National Institutes of Health (NIH) displayed exponential growth and of non-NIH-funded articles displayed linear growth (p < 0.0001 for each). A negligible relation was observed between journal impact factor and number of authors (Pearson r = 0.1066). Radiology has had a steady increase in mean number of authors per paper since the early 1990s that has varied by study design. The increase is probably multi-factorial and includes components of author inflation and increasing complexity of research. Findings support the need for reemphasis of authorship criteria to preserve authorship value and accountability.
Inspired by a True Story: Good Night, and Good Luck and Why We Need It
ERIC Educational Resources Information Center
Beck, Bernard
2006-01-01
Why do people refurbish some historical tales from time to time, adding new versions to be displayed publicly? Powerful cultural elements can be invoked for many purposes, and the morals derived from the fables can be quite different. When individuals are blessed with a rich cultural heritage, they may delve into it to find wisdom for themselves…
Optimization of reading conditions for flat panel displays.
Thomas, J A; Chakrabarti, K; Kaczmarek, R V; Maslennikov, A; Mitchell, C A; Romanyukha, A
2006-06-01
Task Group 18 (TG 18) of the American Association of Physicists in Medicine has developed guidelines for Assessment of Display Performance for Medical Imaging Systems. In this document, a method for determination of the maximum room lighting for displays is suggested. It is based on luminance measurements of a black target displayed on each display device at different room illuminance levels. Linear extrapolation of the above luminance measurements vs. room illuminance allows one to determine diffuse and specular reflection coefficients. TG 18 guidelines have established recommended maximum room lighting. It is based on the characterization of the display by its minimum and maximum luminance and the description of room by diffuse and specular coefficients. We carried out these luminance measurements for three selected displays to determine their optimum viewing conditions: one cathode ray tube and two flat panels. We found some problems with the application of the TG 18 guidelines to optimize viewing conditions for IBM T221 flat panels. Introduction of the requirement for minimum room illuminance allows a more accurate determination of the optimal viewing conditions (maximum and minimum room illuminance) for IBM flat panels. It also addresses the possible loss of contrast in medical images on flat panel displays because of the effect of nonlinearity in the dependence of luminance on room illuminance at low room lighting.
Creative display of museum objects within their cultural context
NASA Astrophysics Data System (ADS)
Wang, Shuo; Osanlou, Ardieshir; Excell, Peter
2014-02-01
Most existing holographic display methods concentrate on real object reconstruction, but there is a lack of research on object stories (revealing and presenting histories). To address this challenge, we propose a method, called 4 `ER' (leader, manager, implementer, presenter) to experience and respond objects in a special immersive environment. The key innovation of the 4'ER' method is to introduce the stories (political, historical, etc.) into hard copy holography, so as to synergy art and science for museum objects display. The hologram of an imitation of a blue and white porcelain jar from The Palace Museum, Beijing, China has been made, showing good performance and reflecting different pathway to knowledge.
Gao, Hongfang; Wang, Xiaofei; Li, Man; Qi, Honglan; Gao, Qiang; Zhang, Chengxiao
2017-12-15
A proximity hybridization-regulated electrogenerated chemiluminescence (PLA-ECL) bioassay was developed for the detection of α-fetoprotein (AFP) on basis of the sensitization of gold nanoparticles (AuNPs) and target-induced quenching mechanism. Ru(bpy) 3 2+ was used as ECL signal while ferrocene (Fc) was used as ECL quencher. Ru(bpy) 3 2+ was electrostatically adsorbed into the AuNPs/Nafion film prepared by casting the mixture of Nafion and AuNPs onto the surface of glassy carbon electrode (GCE) to form an ECL platform (Ru(bpy) 3 2+ /AuNPs/Nafion/GCE), which displayed strong ECL emissions. A recognition platform was fabricated by self-assembling a capture DNA via thiol-gold bond on the surface of Ru(bpy) 3 2+ /AuNPs/Nafion/GCE. After sandwich immunoassay and proximity hybridization assay among capture DNA, AFP, a pair of antibody-oligonucleotide conjugates and a signal probe (DNA-Fc), Fc in DNA-Fc was brought close to the surface of electrode in conjunction with target induced ECL quenching. The ECL intensity decreased with the increasing concentration of the AFP and AFP was monitored with a linear range of 0.05-50ng/mL along with a detection limit of 0.04ng/mL. The ECL bioassay is successfully applied to the detection of AFP in serum samples with one-step recognition, short operating time and good accuracy. This method displays great potential for point-of-care testing and commercial application. Copyright © 2017 Elsevier B.V. All rights reserved.
The Use of Orthogonal Polarizations in Microwave Imagery of Isolated Canine Kidney
NASA Astrophysics Data System (ADS)
Larsen, L. E.; Jacobi, J. H.
1980-06-01
A method of imaging biological targets using microwave radiation at a frequency of 4 GHz is presented. Linearly polarized radiation is transmitted through an isolated canine kidney and received with co-polarized and cross-polarized antennas. Images are displayed as the spatial variation of the magnitude of the transmission scattering parameter S21 for each mode of polarization. The relationship between the spatial variation of the magnitude of S21 and canine renal anatomy is discussed. It is shown that within the kidney the cross-polarized image tends to emphasize linear or piecewise linear structures, whereas the co-polarized image balances renal cortical lobulations.
Hegarty, Mary; Canham, Matt S; Fabrikant, Sara I
2010-01-01
Three experiments examined how bottom-up and top-down processes interact when people view and make inferences from complex visual displays (weather maps). Bottom-up effects of display design were investigated by manipulating the relative visual salience of task-relevant and task-irrelevant information across different maps. Top-down effects of domain knowledge were investigated by examining performance and eye fixations before and after participants learned relevant meteorological principles. Map design and knowledge interacted such that salience had no effect on performance before participants learned the meteorological principles; however, after learning, participants were more accurate if they viewed maps that made task-relevant information more visually salient. Effects of display design on task performance were somewhat dissociated from effects of display design on eye fixations. The results support a model in which eye fixations are directed primarily by top-down factors (task and domain knowledge). They suggest that good display design facilitates performance not just by guiding where viewers look in a complex display but also by facilitating processing of the visual features that represent task-relevant information at a given display location. (PsycINFO Database Record (c) 2009 APA, all rights reserved).
Campbell, John P; Cobbold, Mark; Wang, Yanyun; Goodall, Margaret; Bonney, Sarah L; Chamba, Anita; Birtwistle, Jane; Plant, Timothy; Afzal, Zaheer; Jefferis, Roy; Drayson, Mark T
2013-05-31
Monoclonal κ and λ immunoglobulin free light chain (FLC) paraproteins in serum and urine are important markers in the diagnosis and monitoring of B cell dyscrasias. Current nephelometric and turbidimetric methods that use sheep polyclonal antisera to quantify serum FLC have a number of well-observed limitations. In this report, we describe an improved method using specific mouse anti-human FLC monoclonal antibodies (mAbs). Anti-κ and anti-λ FLC mAbs were, separately, covalently coupled to polystyrene Xmap® beads and assayed, simultaneously, in a multi-plex format by Luminex® (mAb assay). The mAbs displayed no cross-reactivity to bound LC, the alternate LC type, or other human proteins and had improved sensitivity and specificity over immunofixation electrophoresis (IFE) and Freelite™. The assay gives good linearity and sensitivity (<1 mg/L), and the competitive inhibition format gave a broad calibration curve up to 437.5 mg/L and prevented anomalous results for samples in antigen excess i.e. high FLC levels. The mAbs displayed good concordance with Freelite™ for the quantitation of normal polyclonal FLC in plasma from healthy donors (n=249). The mAb assay identified all monoclonal FLC in serum from consecutive patient samples (n=1000; 50.1% with monoclonal paraprotein by serum IFE), and all FLC in a large cohort of urine samples tested for Bence Jones proteins (n=13090; 22.8% with monoclonal κ, 9.0% with monoclonal λ, and 0.8% with poly LC detected by urine IFE). Importantly this shows that the mAbs are at least close to the ideal of detecting FLC from all patients and neoplastic plasma cell clones. Given the overall effectiveness of the anti-FLC mAbs, further clinical validation is now warranted on serial samples from a range of patients with B cell disorders. Use of these mAbs on other assay platforms should also be investigated. Copyright © 2013 Elsevier B.V. All rights reserved.
OxfordGrid: a web interface for pairwise comparative map views.
Yang, Hongyu; Gingle, Alan R
2005-12-01
OxfordGrid is a web application and database schema for storing and interactively displaying genetic map data in a comparative, dot-plot, fashion. Its display is composed of a matrix of cells, each representing a pairwise comparison of mapped probe data for two linkage groups or chromosomes. These are arranged along the axes with one forming grid columns and the other grid rows with the degree and pattern of synteny/colinearity between the two linkage groups manifested in the cell's dot density and structure. A mouse click over the selected grid cell launches an image map-based display for the selected cell. Both individual and linear groups of mapped probes can be selected and displayed. Also, configurable links can be used to access other web resources for mapped probe information. OxfordGrid is implemented in C#/ASP.NET and the package, including MySQL schema creation scripts, is available at ftp://cggc.agtec.uga.edu/OxfordGrid/.
Beam steering for virtual/augmented reality displays with a cycloidal diffractive waveplate.
Chen, Haiwei; Weng, Yishi; Xu, Daming; Tabiryan, Nelson V; Wu, Shin-Tson
2016-04-04
We proposed a switchable beam steering device with cycloidal diffractive waveplate (CDW) for eye tracking in a virtual reality (VR) or augmented reality (AR) display system. Such a CDW diffracts the incident circularly polarized light to the first order with over 95% efficiency. To convert the input linearly polarized light to right-handed or left-handed circular polarization, we developed a broadband polarization switch consisting of a twisted nematic liquid crystal cell and an achromatic quarter-wave retardation film. By cascading 2-3 CDWs together, multiple diffraction angles can be achieved. To suppress the color dispersion, we proposed two approaches to obtain the same diffraction angle for red, green, and blue LEDs-based full color displays. Our device exhibits several advantages, such as high diffraction efficiency, fast response time, low power consumption, and low cost. It holds promise for the emerging VR/AR displays.
Lanthanide Diphthalocyanines. Electrochemistry and Display Applications.
1982-01-01
transients, cyclic voltametry (Nicholson and Galiardi, 1977, 1978; Noskalev and Shapkin, 1978). and a novel solid-state moving-boundary technique...was confirmed for the reverse process by linear potential- sweep voltammetry. Although the hydrazine hydrate my not have been simply an inert solvent
Translations on North Korea, Number 607
1978-08-04
in producing many more consumer goods of much better quality. Youth in scientific, educational, literary and artistic circles as well must achieve a...SINMUN in Korean 1 May 78 p 3] MASS GYMNASTIC DISPLAY FOR BOKASSA—The following were seated with Kim Il-song on the viewing platform at the mass... gymnastic display "Song of Korea," which was performed on 1 May at Moranbong Stadium in honor of the visiting Emperor Bokassa I of the Central African
ERIC Educational Resources Information Center
Mitchell, Eugene E., Ed.
The study of the dynamics of physical systems is of importance to all engineering students. LSSP, a Linear System Simulation Program, is used to study the behavior of physical phenomena and systems which may be represented to a good degree of approximation by linear models. Emphasis is placed upon the unity resulting from the mathematical…
2017-12-01
peptide in tumors that was linearly correlated with HER3 levels. Biodistribution analysis revealed low off-target accumulation and rapid clearance...Internal Lab 15-22 Dr. Larimer 5 Stock) Subtask 2: Correlate changes in peptide uptake with protein expression and cell signaling changes ex vivo...signal for each individual tumor was plotted against its corresponding HER3 protein level, the TBR correlated linearly with the amount of protein
Venus orogenic belt environments - Architecture and origin
NASA Astrophysics Data System (ADS)
Head, James W.; Vorder Bruegge, Richard W.; Crumpler, L. S.
1990-08-01
Orogenic belt environments (Danu, Akna, Freyja, and Maxwell Montes) in Western Ishtar Terra, Venus, display a range of architectural elements, including (from the center of Western Ishtar outward) an inboard plateau (Lakshmi Planum), the linear orogenic belts themselves, outboard plateaus, steep scarps bounding Ishtar, adjacent linear foredeeps and outboard rises, and outboard low-lying volcanic plains. The main elements of the architecture are interpreted to be due to the convergence, underthrusting, and possible subduction of lowland plains at the margins of a preexisting tessera plateau of thicker crust.
Display system employing acousto-optic tunable filter
NASA Technical Reports Server (NTRS)
Lambert, James L. (Inventor)
1995-01-01
An acousto-optic tunable filter (AOTF) is employed to generate a display by driving the AOTF with a RF electrical signal comprising modulated red, green, and blue video scan line signals and scanning the AOTF with a linearly polarized, pulsed light beam, resulting in encoding of color video columns (scan lines) of an input video image into vertical columns of the AOTF output beam. The AOTF is illuminated periodically as each acoustically-encoded scan line fills the cell aperture of the AOTF. A polarizing beam splitter removes the unused first order beam component of the AOTF output and, if desired, overlays a real world scene on the output plane. Resolutions as high as 30,000 lines are possible, providing holographic display capability.
Display system employing acousto-optic tunable filter
NASA Technical Reports Server (NTRS)
Lambert, James L. (Inventor)
1993-01-01
An acousto-optic tunable filter (AOTF) is employed to generate a display by driving the AOTF with a RF electrical signal comprising modulated red, green, and blue video scan line signals and scanning the AOTF with a linearly polarized, pulsed light beam, resulting in encoding of color video columns (scan lines) of an input video image into vertical columns of the AOTF output beam. The AOTF is illuminated periodically as each acoustically-encoded scan line fills the cell aperture of the AOTF. A polarizing beam splitter removes the unused first order beam component of the AOTF output and, if desired, overlays a real world scene on the output plane. Resolutions as high as 30,000 lines are possible, providing holographic display capability.
Digital 3D holographic display using scattering layers for enhanced viewing angle and image size
NASA Astrophysics Data System (ADS)
Yu, Hyeonseung; Lee, KyeoReh; Park, Jongchan; Park, YongKeun
2017-05-01
In digital 3D holographic displays, the generation of realistic 3D images has been hindered by limited viewing angle and image size. Here we demonstrate a digital 3D holographic display using volume speckle fields produced by scattering layers in which both the viewing angle and the image size are greatly enhanced. Although volume speckle fields exhibit random distributions, the transmitted speckle fields have a linear and deterministic relationship with the input field. By modulating the incident wavefront with a digital micro-mirror device, volume speckle patterns are controlled to generate 3D images of micrometer-size optical foci with 35° viewing angle in a volume of 2 cm × 2 cm × 2 cm.
Image Fluctuations in LED Electromechanical 3D-Display
NASA Astrophysics Data System (ADS)
Klyuev, Alexey V.; Yakimov, Arkady V.
Fluctuations in parameters of light-emitting diode (LED) electromechanical 3D-display are investigated. It is shown, that there are two types of fluctuations in the rotating 3D-display. The first one is caused by a small increment in the rotation angle, which has a tendency to the increase. That occurs in the form of the “drift” without periodic changes of the angle. The second one is the change in small linear increments of the angle, which occurs as undamped harmonic oscillations with constant amplitude. This shows the stability of the investigated steady state because there is no tendency to increase the amplitude of the considered parameter regime. In conclusion we give some recommendations how to improve synchronization of the system.
Visual search in a forced-choice paradigm
NASA Technical Reports Server (NTRS)
Holmgren, J. E.
1974-01-01
The processing of visual information was investigated in the context of two visual search tasks. The first was a forced-choice task in which one of two alternative letters appeared in a visual display of from one to five letters. The second task included trials on which neither of the two alternatives was present in the display. Search rates were estimated from the slopes of best linear fits to response latencies plotted as a function of the number of items in the visual display. These rates were found to be much slower than those estimated in yes-no search tasks. This result was interpreted as indicating that the processes underlying visual search in yes-no and forced-choice tasks are not the same.
Next generation smart window display using transparent organic display and light blocking screen.
Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk
2018-04-02
Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.
7 CFR 253.10 - Commodity control, storage and distribution.
Code of Federal Regulations, 2010 CFR
2010-01-01
... recorded. (15) Posters are conspicuously displayed advising program participants to accept only those... commodities with the same or similar kind of commodities which are sound and in good condition. The State...
Kelly, Glenn; Simpson, Grahame K; Brown, Suzanne; Kremer, Peter; Gillett, Lauren
2017-05-23
The objectives were to test the properties, via a psychometric study, of the Overt Behaviour Scale-Self-Report (OBS-SR), a version of the OBS-Adult Scale developed to provide a client perspective on challenging behaviours after acquired brain injury. Study sample 1 consisted of 37 patients with primary brain tumour (PBT) and a family-member informant. Sample 2 consisted of 34 clients with other acquired brain injury (mixed brain injury, MBI) and a service-provider informant. Participants completed the OBS-SR (at two time points), and the Awareness Questionnaire (AQ) and Mayo Portland Adaptability Inventory-III (MPAI-III) once; informants completed the OBS-Adult and AQ once only. PBT-informant dyads displayed "good" levels of agreement (ICC 2,k = .74; OBS-SR global index). Although MBI-informant dyads displayed no agreement (ICC 2,k = .22; OBS-SR global index), the sub-group (17/29) rated by clinicians as having moderate to good levels of awareness displayed "fair" agreement (ICC 2,k = .58; OBS-SR global index). Convergent/divergent validity was demonstrated by significant correlations between OBS-SR subscales and MPAI-III subscales with behavioural content (coefficients in the range .36 -.61). Scores had good reliability across one week (ICC 2,k = .69). The OBS-SR took approximately 15 minutes to complete. It was concluded that the OBS-SR demonstrated acceptable reliability and validity, providing a useful resource in understanding clients' perspectives about their behaviour.
Wright, Alison J; Whitwell, Sophia C L; Takeichi, Chika; Hankins, Matthew; Marteau, Theresa M
2009-02-01
Numeracy, the ability to process basic mathematical concepts, may affect responses to graphical displays of health risk information. Displays of probabilistic risk information using grouped dots are easier to understand than displays using dispersed dots. However, dispersed dots may better convey the randomness with which health threats occur, so increasing perceived susceptibility. We hypothesized that low numeracy participants would better understand risks presented using grouped dot displays, while high numeracy participants would have good understanding, regardless of display type. Moreover, we predicted that dispersed dot displays, in contrast to grouped dot displays, would increase risk perceptions and worry only for highly numerate individuals. One hundred and forty smokers read vignettes asking them to imagine being at risk of Crohn's disease, in a 2(display type: dispersed/grouped dots) x 3(risk magnitude: 3%/6%/50%) x 2(numeracy: high/low) design. They completed measures of risk comprehension, perceived susceptibility and worry. More numerate participants had better objective risk comprehension, but this effect was not moderated by display type. There was marginally significant support for the predicted numeracy x display type interaction for worry about Crohn's disease, but not for perceived susceptibility to the condition. Dispersed dot displays somewhat increase worry in highly numerate individuals, but only numeracy influenced objective risk comprehension. The most effective display type for communicating risk information will depend on the numeracy of the population and the goal(s) of the communication.
Room temperature giant and linear magnetoresistance in topological insulator Bi2Te3 nanosheets.
Wang, Xiaolin; Du, Yi; Dou, Shixue; Zhang, Chao
2012-06-29
Topological insulators, a new class of condensed matter having bulk insulating states and gapless metallic surface states, have demonstrated fascinating quantum effects. However, the potential practical applications of the topological insulators are still under exploration worldwide. We demonstrate that nanosheets of a Bi(2)Te(3) topological insulator several quintuple layers thick display giant and linear magnetoresistance. The giant and linear magnetoresistance achieved is as high as over 600% at room temperature, with a trend towards further increase at higher temperatures, as well as being weakly temperature-dependent and linear with the field, without any sign of saturation at measured fields up to 13 T. Furthermore, we observed a magnetic field induced gap below 10 K. The observation of giant and linear magnetoresistance paves the way for 3D topological insulators to be useful for practical applications in magnetoelectronic sensors such as disk reading heads, mechatronics, and other multifunctional electromagnetic applications.
Origin of nonsaturating linear magnetoresistivity
NASA Astrophysics Data System (ADS)
Kisslinger, Ferdinand; Ott, Christian; Weber, Heiko B.
2017-01-01
The observation of nonsaturating classical linear magnetoresistivity has been an enigmatic phenomenon in solid-state physics. We present a study of a two-dimensional ohmic conductor, including local Hall effect and a self-consistent consideration of the environment. An equivalent-circuit scheme delivers a simple and convincing argument why the magnetoresistivity is linear in strong magnetic field, provided that current and biasing electric field are misaligned by a nonlocal mechanism. A finite-element model of a two-dimensional conductor is suited to display the situations that create such deviating currents. Besides edge effects next to electrodes, charge carrier density fluctuations are efficiently generating this effect. However, mobility fluctuations that have frequently been related to linear magnetoresistivity are barely relevant. Despite its rare observation, linear magnetoresitivity is rather the rule than the exception in a regime of low charge carrier densities, misaligned current pathways and strong magnetic field.
Vector Adaptive/Predictive Encoding Of Speech
NASA Technical Reports Server (NTRS)
Chen, Juin-Hwey; Gersho, Allen
1989-01-01
Vector adaptive/predictive technique for digital encoding of speech signals yields decoded speech of very good quality after transmission at coding rate of 9.6 kb/s and of reasonably good quality at 4.8 kb/s. Requires 3 to 4 million multiplications and additions per second. Combines advantages of adaptive/predictive coding, and code-excited linear prediction, yielding speech of high quality but requires 600 million multiplications and additions per second at encoding rate of 4.8 kb/s. Vector adaptive/predictive coding technique bridges gaps in performance and complexity between adaptive/predictive coding and code-excited linear prediction.
A study of temperature-related non-linearity at the metal-silicon interface
NASA Astrophysics Data System (ADS)
Gammon, P. M.; Donchev, E.; Pérez-Tomás, A.; Shah, V. A.; Pang, J. S.; Petrov, P. K.; Jennings, M. R.; Fisher, C. A.; Mawby, P. A.; Leadley, D. R.; McN. Alford, N.
2012-12-01
In this paper, we investigate the temperature dependencies of metal-semiconductor interfaces in an effort to better reproduce the current-voltage-temperature (IVT) characteristics of any Schottky diode, regardless of homogeneity. Four silicon Schottky diodes were fabricated for this work, each displaying different degrees of inhomogeneity; a relatively homogeneous NiV/Si diode, a Ti/Si and Cr/Si diode with double bumps at only the lowest temperatures, and a Nb/Si diode displaying extensive non-linearity. The 77-300 K IVT responses are modelled using a semi-automated implementation of Tung's electron transport model, and each of the diodes are well reproduced. However, in achieving this, it is revealed that each of the three key fitting parameters within the model display a significant temperature dependency. In analysing these dependencies, we reveal how a rise in thermal energy "activates" exponentially more interfacial patches, the activation rate being dependent on the carrier concentration at the patch saddle point (the patch's maximum barrier height), which in turn is linked to the relative homogeneity of each diode. Finally, in a review of Tung's model, problems in the divergence of the current paths at low temperature are explained to be inherent due to the simplification of an interface that will contain competing defects and inhomogeneities.
Spreco, A; Eriksson, O; Dahlström, Ö; Timpka, T
2017-07-01
Methods for the detection of influenza epidemics and prediction of their progress have seldom been comparatively evaluated using prospective designs. This study aimed to perform a prospective comparative trial of algorithms for the detection and prediction of increased local influenza activity. Data on clinical influenza diagnoses recorded by physicians and syndromic data from a telenursing service were used. Five detection and three prediction algorithms previously evaluated in public health settings were calibrated and then evaluated over 3 years. When applied on diagnostic data, only detection using the Serfling regression method and prediction using the non-adaptive log-linear regression method showed acceptable performances during winter influenza seasons. For the syndromic data, none of the detection algorithms displayed a satisfactory performance, while non-adaptive log-linear regression was the best performing prediction method. We conclude that evidence was found for that available algorithms for influenza detection and prediction display satisfactory performance when applied on local diagnostic data during winter influenza seasons. When applied on local syndromic data, the evaluated algorithms did not display consistent performance. Further evaluations and research on combination of methods of these types in public health information infrastructures for 'nowcasting' (integrated detection and prediction) of influenza activity are warranted.
Evaluation of force-torque displays for use with space station telerobotic activities
NASA Technical Reports Server (NTRS)
Hendrich, Robert C.; Bierschwale, John M.; Manahan, Meera K.; Stuart, Mark A.; Legendre, A. Jay
1992-01-01
Recent experiments which addressed Space Station remote manipulation tasks found that tactile force feedback (reflecting forces and torques encountered at the end-effector through the manipulator hand controller) does not improve performance significantly. Subjective response from astronaut and non-astronaut test subjects indicated that force information, provided visually, could be useful. No research exists which specifically investigates methods of presenting force-torque information visually. This experiment was designed to evaluate seven different visual force-torque displays which were found in an informal telephone survey. The displays were prototyped in the HyperCard programming environment. In a within-subjects experiment, 14 subjects nullified forces and torques presented statically, using response buttons located at the bottom of the screen. Dependent measures included questionnaire data, errors, and response time. Subjective data generally demonstrate that subjects rated variations of pseudo-perspective displays consistently better than bar graph and digital displays. Subjects commented that the bar graph and digital displays could be used, but were not compatible with using hand controllers. Quantitative data show similar trends to the subjective data, except that the bar graph and digital displays both provided good performance, perhaps do to the mapping of response buttons to display elements. Results indicate that for this set of displays, the pseudo-perspective displays generally represent a more intuitive format for presenting force-torque information.
Optimal read/write memory system components
NASA Technical Reports Server (NTRS)
Kozma, A.; Vander Lugt, A.; Klinger, D.
1972-01-01
Two holographic data storage and display systems, voltage gradient ionization system, and linear strain manipulation system are discussed in terms of creating fast, high bit density, storage device. Components described include: novel mounting fixture for photoplastic arrays; corona discharge device; and block data composer.
How colorful! A feature it is, isn't it?
NASA Astrophysics Data System (ADS)
Lebowsky, Fritz
2015-01-01
A display's color subpixel geometry provides an intriguing opportunity for improving readability of text. True type fonts can be positioned at the precision of subpixel resolution. With such a constraint in mind, how does one need to design font characteristics? On the other hand, display manufactures try hard in addressing the color display's dilemma: smaller pixel pitch and larger display diagonals strongly increase the total number of pixels. Consequently, cost of column and row drivers as well as power consumption increase. Perceptual color subpixel rendering using color component subsampling may save about 1/3 of color subpixels (and reduce power dissipation). This talk will try to elaborate the following questions, based on simulation of several different layouts of subpixel matrices: Up to what level are display device constraints compatible with software specific ideas of rendering text? How much of color contrast will remain? How to best consider preferred viewing distance for readability of text? How much does visual acuity vary at 20/20 vision? Can simplified models of human visual color perception be easily applied to text rendering on displays? How linear is human visual contrast perception around band limit of a display's spatial resolution? How colorful does the rendered text appear on the screen? How much does viewing angle influence the performance of subpixel layouts and color subpixel rendering?
An Evaluation and Comparison of Several Measures of Image Quality for Television Displays
1979-01-01
vehicles, buildings, or faces , or they may be artificial much as trn-bar patterns, rectangles, or sine waves. The typical objective image quality assessment...Snyder (1974b) wac able to obtain very good correlations with reaction time and correct responses for a face recognition task. Display quality was varied...recognition versus log JUDA for the target recognition study of Chapter 4, 5) graph of angle oubtended by target at recognitio , versus log JNDA for the
Attenuated phase-shift mask (PSM) blanks for flat panel display
NASA Astrophysics Data System (ADS)
Kageyama, Kagehiro; Mochizuki, Satoru; Yamakawa, Hiroyuki; Uchida, Shigeru
2015-10-01
The fine pattern exposure techniques are required for Flat Panel display applications as smart phone, tablet PC recently. The attenuated phase shift masks (PSM) are being used for ArF and KrF photomask lithography technique for high end pattern Semiconductor applications. We developed CrOx based large size PSM blanks that has good uniformity on optical characteristics for FPD applications. We report the basic optical characteristics and uniformity, stability data of large sized CrOx PSM blanks.
A higher order panel method for linearized supersonic flow
NASA Technical Reports Server (NTRS)
Ehlers, F. E.; Epton, M. A.; Johnson, F. T.; Magnus, A. E.; Rubbert, P. E.
1979-01-01
The basic integral equations of linearized supersonic theory for an advanced supersonic panel method are derived. Methods using only linear varying source strength over each panel or only quadratic doublet strength over each panel gave good agreement with analytic solutions over cones and zero thickness cambered wings. For three dimensional bodies and wings of general shape, combined source and doublet panels with interior boundary conditions to eliminate the internal perturbations lead to a stable method providing good agreement experiment. A panel system with all edges contiguous resulted from dividing the basic four point non-planar panel into eight triangular subpanels, and the doublet strength was made continuous at all edges by a quadratic distribution over each subpanel. Superinclined panels were developed and tested on s simple nacelle and on an airplane model having engine inlets, with excellent results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mandal, P.; Anantha Ramakrishna, S.; Patil, Raj
2013-12-14
An array of H-shaped subwavelength slits in a plasmonic film has a polarization dependent extra-ordinary transmission due to shape anisotropy. Non-overlapping extra-ordinary transmission bands for the orthogonal linear polarization states of the input light are used to demonstrate a polarization dependent color switch. The fabricated array of submicron sized H-slits on a gold film displayed two transmission bands for the linear x- and y-polarized light at visible (650–850 nm) and near-infra-red (1150–1450 nm) bands, respectively. The relative transmitted light in these two bands can be controlled by changing the linear polarization state of the input radiation from 0° to 90°.
Validation of a new digital breast tomosynthesis medical display
NASA Astrophysics Data System (ADS)
Marchessoux, Cédric; Vivien, Nicolas; Kumcu, Asli; Kimpe, Tom
2011-03-01
The main objective of this study is to evaluate and validate the new Barco medical display MDMG-5221 which has been optimized for the Digital Breast Tomosynthesis (DBT) imaging modality system, and to prove the benefit of the new DBT display in terms of image quality and clinical performance. The clinical performance is evaluated by the detection of micro-calcifications inserted in reconstructed Digital Breast Tomosynthesis slices. The slices are shown in dynamic cine loops, at two frames rates. The statistical analysis chosen for this study is the Receiver Operating Characteristic Multiple-Reader, Multiple-Case methodology, in order to measure the clinical performance of the two displays. Four experienced radiologists are involved in this study. For this clinical study, 50 normal and 50 abnormal independent datasets were used. The result is that the new display outperforms the mammography display for a signal detection task using real DBT images viewed at 25 and 50 slices per second. In the case of 50 slices per second, the p-value = 0.0664. For a cut-off where alpha=0.05, the conclusion is that the null hypothesis cannot be rejected, however the trend is that the new display performs 6% better than the old display in terms of AUC. At 25 slices per second, the difference between the two displays is very apparent. The new display outperforms the mammography display by 10% in terms of AUC, with a good statistical significance of p=0.0415.
A volumetric three-dimensional digital light photoactivatable dye display
NASA Astrophysics Data System (ADS)
Patel, Shreya K.; Cao, Jian; Lippert, Alexander R.
2017-07-01
Volumetric three-dimensional displays offer spatially accurate representations of images with a 360° view, but have been difficult to implement due to complex fabrication requirements. Herein, a chemically enabled volumetric 3D digital light photoactivatable dye display (3D Light PAD) is reported. The operating principle relies on photoactivatable dyes that become reversibly fluorescent upon illumination with ultraviolet light. Proper tuning of kinetics and emission wavelengths enables the generation of a spatial pattern of fluorescent emission at the intersection of two structured light beams. A first-generation 3D Light PAD was fabricated using the photoactivatable dye N-phenyl spirolactam rhodamine B, a commercial picoprojector, an ultraviolet projector and a custom quartz imaging chamber. The system displays a minimum voxel size of 0.68 mm3, 200 μm resolution and good stability over repeated `on-off' cycles. A range of high-resolution 3D images and animations can be projected, setting the foundation for widely accessible volumetric 3D displays.
Image degradation by glare in radiologic display devices
NASA Astrophysics Data System (ADS)
Badano, Aldo; Flynn, Michael J.
1997-05-01
No electronic devices are currently available that can display digital radiographs without loss of visual information compared to traditional transilluminated film. Light scattering within the glass faceplate of cathode-ray tube (CRT) devices causes excessive glare that reduces image contrast. This glare, along with ambient light reflection, has been recognized as a significant limitation for radiologic applications. Efforts to control the effect of glare and ambient light reflection in CRTs include the use of absorptive glass and thin film coatings. In the near future, flat panel displays (FPD) with thin emissive structures should provide very low glare, high performance devices. We have used an optical Monte Carlo simulation to evaluate the effect of glare on image quality for typical CRT and flat panel display devices. The trade-off between display brightness and image contrast is described. For CRT systems, achieving good glare ratio requires a reduction of brightness to 30-40 percent of the maximum potential brightness. For FPD systems, similar glare performance can be achieved while maintaining 80 percent of the maximum potential brightness.
Apparent minification in an imaging display under reduced viewing conditions.
Meehan, J W
1993-01-01
When extended outdoor scenes are imaged with magnification of 1 in optical, electronic, or computer-generated displays, scene features appear smaller and farther than in direct view. This has been shown to occur in various periscopic and camera-viewfinder displays outdoors in daylight. In four experiments it was found that apparent minification of the size of a planar object at a distance of 3-9 m indoors occurs in the viewfinder display of an SLR camera both in good light and in darkness with only the luminous object visible. The effect is robust and survives changes in the relationship between object luminance in the display and in direct view and occurs in the dark when subjects have no prior knowledge of room dimensions, object size or object distance. The results of a fifth experiment suggest that the effect is an instance of reduced visual size constancy consequent on elimination of cues for size, which include those for distance.
A volumetric three-dimensional digital light photoactivatable dye display
Patel, Shreya K.; Cao, Jian; Lippert, Alexander R.
2017-01-01
Volumetric three-dimensional displays offer spatially accurate representations of images with a 360° view, but have been difficult to implement due to complex fabrication requirements. Herein, a chemically enabled volumetric 3D digital light photoactivatable dye display (3D Light PAD) is reported. The operating principle relies on photoactivatable dyes that become reversibly fluorescent upon illumination with ultraviolet light. Proper tuning of kinetics and emission wavelengths enables the generation of a spatial pattern of fluorescent emission at the intersection of two structured light beams. A first-generation 3D Light PAD was fabricated using the photoactivatable dye N-phenyl spirolactam rhodamine B, a commercial picoprojector, an ultraviolet projector and a custom quartz imaging chamber. The system displays a minimum voxel size of 0.68 mm3, 200 μm resolution and good stability over repeated ‘on-off’ cycles. A range of high-resolution 3D images and animations can be projected, setting the foundation for widely accessible volumetric 3D displays. PMID:28695887
Nguyen, Giang Kien Truc; Lian, Yilong; Pang, Edmund Weng Hou; Nguyen, Phuong Quoc Thuc; Tran, Tuan Dinh; Tam, James P.
2013-01-01
Cyclotides are disulfide-rich macrocyclic peptides that display a wide range of bioactivities and represent an important group of plant defense peptide biologics. A few linear variants of cyclotides have recently been identified. They share a high sequence homology with cyclotides but are biosynthetically unable to cyclize from their precursors. All hitherto reported cyclotides and their acyclic variants were isolated from dicot plants of the Rubiaceae, Violaceae, Cucurbitaceae, and recently the Fabaceae and Solanaceae families. Although several cyclotide-like genes in the Poaceae family were known from the data mining of the National Center for Biotechnology Information (NCBI) nucleotide database, their expression at the protein level has yet to be proven. Here, we report the discovery and characterization of nine novel linear cyclotides, designated as panitides L1–9, from the Panicum laxum of the Poaceae family and provide the first evidence of linear cyclotides at the protein level in a monocot plant. Disulfide mapping of panitide L3 showed that it possesses a cystine knot arrangement similar to cyclotides. Several panitides were shown to be active against Escherichia coli and cytotoxic to HeLa cells. They also displayed a high stability against heat and proteolytic degradation. Oxidative folding of the disulfide-reduced panitide L1 showed that it can fold efficiently into its native form. The presence of linear cyclotides in both dicots and monocots suggests their ancient origin and existence before the divergence of these two groups of flowering plants. Moreover, the Poaceae family contains many important food crops, and our discovery may open up new avenues of research using cyclotides and their acyclic variants in crop protection. PMID:23195955
Yoon, Yeomin; Noh, Suwoo; Jeong, Jiseong; Park, Kyihwan
2018-05-01
The topology image is constructed from the 2D matrix (XY directions) of heights Z captured from the force-feedback loop controller. For small height variations, nonlinear effects such as hysteresis or creep of the PZT-driven Z nano scanner can be neglected and its calibration is quite straightforward. For large height variations, the linear approximation of the PZT-driven Z nano scanner fail and nonlinear behaviors must be considered because this would cause inaccuracies in the measurement image. In order to avoid such inaccuracies, an additional strain gauge sensor is used to directly measure displacement of the PZT-driven Z nano scanner. However, this approach also has a disadvantage in its relatively low precision. In order to obtain high precision data with good linearity, we propose a method of overcoming the low precision problem of the strain gauge while its feature of good linearity is maintained. We expect that the topology image obtained from the strain gauge sensor showing significant noise at high frequencies. On the other hand, the topology image obtained from the controller output showing low noise at high frequencies. If the low and high frequency signals are separable from both topology images, the image can be constructed so that it is represented with high accuracy and low noise. In order to separate the low frequencies from high frequencies, a 2D Haar wavelet transform is used. Our proposed method use the 2D wavelet transform for obtaining good linearity from strain gauge sensor and good precision from controller output. The advantages of the proposed method are experimentally validated by using topology images. Copyright © 2018 Elsevier B.V. All rights reserved.
How to use a phase-only spatial light modulator as a color display.
Harm, Walter; Jesacher, Alexander; Thalhammer, Gregor; Bernet, Stefan; Ritsch-Marte, Monika
2015-02-15
We demonstrate that a parallel aligned liquid crystal on silicon (PA-LCOS) spatial light modulator (SLM) without any attached color mask can be used as a full color display with white light illumination. The method is based on the wavelength dependence of the (voltage controlled) birefringence of the liquid crystal pixels. Modern SLMs offer a wide range over which the birefringence can be modulated, leading (in combination with a linear polarizer) to several intensity modulation periods of a reflected light wave as a function of the applied voltage. Because of dispersion, the oscillation period strongly depends on the wavelength. Thus each voltage applied to an SLM pixel corresponds to another reflected color spectrum. For SLMs with a sufficiently broad tuning range, one obtains a color palette (i.e., a "color lookup-table"), which allows one to display color images. An advantage over standard liquid crystal displays (LCDs), which use color masks in front of the individual pixels, is that the light efficiency and the display resolution are increased by a factor of three.
Kafi, A K M; Naqshabandi, M; Yusoff, Mashitah M; Crossley, Maxwell J
2018-06-01
A new 3-dimensional (3D) network of crosslinked Horseradish Peroxidase/Carbon Nanotube (HRP/CNT) on a thiol-modified Au surface has been described in order to build up the effective electrical wiring of the enzyme units with the electrode. The synthesized 3D HRP/CNT network has been characterized with cyclic voltammetry and amperometry which results the establishment of direct electron transfer between the redox active unit of HRP and the Au surface. Electrochemical measurements reveal that the high biological activity and stability is exhibited by the immobilized HRP and a quasi-reversible redox peak of the redox centre of HRP was observed at about -0.355 and -0.275V vs. Ag/AgCl. The electron transfer rate constant, K S and electron transfer co-efficient α were found as 0.57s -1 and 0.42, respectively. Excellent electrocatalytic activity for the reduction of H 2 O 2 was exhibited by the developed biosensor. The proposed biosensor modified with HRP/CNT 3D network displays a broader linear range and a lower detection limit for H 2 O 2 determination. The linear range is from 1.0×10 -7 to 1.2×10 -4 M with a detection limit of 2.2.0×10 -8 M at 3σ. The Michaelies-Menten constant Kapp M value is estimated to be 0.19mM. Moreover, this biosensor exhibits very high sensitivity, good reproducibility and long-time stability. Copyright © 2017 Elsevier Inc. All rights reserved.
Graphite paper-based bipolar electrode electrochemiluminescence sensing platform.
Zhang, Xin; Ding, Shou-Nian
2017-08-15
In this work, aiming at the construction of a disposable, wireless, low-cost and sensitive system for bioassay, we report a closed bipolar electrode electrochemiluminescence (BPE-ECL) sensing platform based on graphite paper as BPE for the first time. Graphite paper is qualified as BPE due to its unique properties such as excellent electrical conductivity, uniform composition and ease of use. This simple BPE-ECL device was applied to the quantitative analysis of oxidant (H 2 O 2 ) and biomarker (CEA) respectively, according to the principle of BPE sensing-charge balance. For the H 2 O 2 analysis, Pt NPs were electrodeposited onto the cathode through a bipolar electrodeposition approach to promote the sensing performance. As a result, this BPE-ECL device exhibited a wide linear range of 0.001-15mM with a low detection limit of 0.5µM (S/N=3) for H 2 O 2 determination. For the determination of CEA, chitosan-multi-walled carbon nanotubes (CS-MWCNTs) were employed to supply a hydrophilic interface for immobilizing primary antibody (Ab 1 ); and Au@Pt nanostructures were conjugated with secondary antibody (Ab 2 ) as catalysts for H 2 O 2 reduction. Under the optimal conditions, the BPE-ECL immunodevice showed a wide linear range of 0.01-60ngmL -1 with a detection limit of 5.0pgmL -1 for CEA. Furthermore, it also displayed satisfactory selectivity, excellent stability and good reproducibility. The developed method opened a new avenue to clinical bioassay. Copyright © 2017 Elsevier B.V. All rights reserved.
Simulating energy cascade of shock wave formation process in a resonator by gas kinetic scheme
NASA Astrophysics Data System (ADS)
Qu, Chengwu; Zhang, Xiaoqing; Feng, Heying
2017-12-01
The temporal-spatial evolution of gas oscillation was simulated by gas kinetic scheme (GKS) in a cylindrical resonator, driven by a piston at one end and rigidly closed at the other end. Periodic shock waves propagating back and forth were observed in the resonator under finite amplitude of gas oscillation. The studied results demonstrated that the acoustic pressure is a saw-tooth waveform and the oscillatory velocity is a square waveform at the central position of the resonant tube. Moreover, it was found by harmonic analysis that there was no presence of obvious feature for pressure node in such a typical standing wave resonator, and the distribution of acoustic fields displayed a one-dimensional feature for the acoustic pressure while a quasi-one-dimensional form for oscillatory velocity, which demonstrated the nonlinear effects. The simulation results for axial distribution of acoustic intensity showed a good consistency with the published experimental data in the open literature domain, which provides a verification for the effectiveness of the GKS model proposed. The influence of displacement amplitude of the driving piston on the formation of shock wave was numerically investigated, and the simulated results revealed the cascade process of harmonic wave energy from the fundamental wave to higher harmonics. In addition, this study found that the acoustic intensity at the driving end of the resonant tube would increase linearly with the displacement amplitude of the piston due to nonlinear effects, rather than the exponential variation by linear theory. This research demonstrates that the GKS model is strongly capable of simulating nonlinear acoustic problems.
ERIC Educational Resources Information Center
Mandys, Frantisek; Dolan, Conor V.; Molenaar, Peter C. M.
1994-01-01
Studied the conditions under which the quasi-Markov simplex model fits a linear growth curve covariance structure and determined when the model is rejected. Presents a quasi-Markov simplex model with structured means and gives an example. (SLD)
ERIC Educational Resources Information Center
de Villiers, Michael
2011-01-01
Symmetry is found in the visual arts, architecture and design of artefacts since the earliest time. Many natural objects, both organic and inorganic, display symmetry: from microscopic crystals and sub-atomic particles to macro-cosmic galaxies. Today it features strongly in higher mathematics such as Linear and Abstract Algebra, Projective and…
A laser spectrometer and wavemeter for pulsed lasers
NASA Technical Reports Server (NTRS)
Mckay, J. A.; Laufer, P. M.; Cotnoir, L. J.
1989-01-01
The design, construction, calibration, and evaluation of a pulsed laser wavemeter and spectral analyzer are described. This instrument, called the Laserscope for its oscilloscope-like display of laser spectral structure, was delivered to NASA Langley Research Center as a prototype of a laboratory instrument. The key component is a multibeam Fizeau wedge interferometer, providing high (0.2 pm) spectral resolution and a linear dispersion of spectral information, ideally suited to linear array photodiode detectors. Even operating alone, with the classic order-number ambiguity of interferometers unresolved, this optical element will provide a fast, real-time display of the spectral structure of a laser output. If precise wavelength information is also desired then additional stages must be provided to obtain a wavelength measurement within the order-number uncertainty, i.e., within the free spectral range of the Fizeau wedge interferometer. A Snyder (single-beam Fizeau) wedge is included to provide this initial wavelength measurement. Difficulties in achieving the required wide-spectrum calibration limit the usefulness of this function.
A dual-loop model of the human controller in single-axis tracking tasks
NASA Technical Reports Server (NTRS)
Hess, R. A.
1977-01-01
A dual loop model of the human controller in single axis compensatory tracking tasks is introduced. This model possesses an inner-loop closure which involves feeding back that portion of the controlled element output rate which is due to control activity. The sensory inputs to the human controller are assumed to be system error and control force. The former is assumed to be sensed via visual, aural, or tactile displays while the latter is assumed to be sensed in kinesthetic fashion. A nonlinear form of the model is briefly discussed. This model is then linearized and parameterized. A set of general adaptive characteristics for the parameterized model is hypothesized. These characteristics describe the manner in which the parameters in the linearized model will vary with such things as display quality. It is demonstrated that the parameterized model can produce controller describing functions which closely approximate those measured in laboratory tracking tasks for a wide variety of controlled elements.
Brown, Jeremy D; Shelley, Mackenzie K; Gardner, Duane; Gansallo, Emmanuel A; Gillespie, R Brent
2016-01-01
An important goal of haptic display is to make available the action/reaction relationships that define interactions between the body and the physical world. While in physical world interactions reaction cues invariably impinge on the same part of the body involved in action (reaction and action are colocated), a haptic interface is quite capable of rendering feedback to a separate body part than that used for producing exploratory actions (non-colocated action and reaction). This most commonly occurs with the use of vibrotactile display, in which a cutaneous cue has been substituted for a kinesthetic cue (a kind of sensory substitution). In this paper, we investigate whether non-colocated force and displacement cues degrade the perception of compliance. Using a custom non-colocated kinesthetic display in which one hand controls displacement and the other senses force, we ask participants to discriminate between two virtual springs with matched terminal force and adjustable non-linearity. An additional condition includes one hand controlling displacement while the other senses force encoded in a vibrotactile cue. Results show that when the terminal force cue is unavailable, and even when sensory substitution is not involved, non-colocated kinesthetic displays degrade compliance discrimination relative to colocated kinesthetic displays. Compliance discrimination is also degraded with vibrotactile display of force. These findings suggest that non-colocated kinesthetic displays and, likewise, cutaneous sensory substitution displays should be avoided when discrimination of compliance is necessary for task success.
Analysis of ERTS-1 linear features in New York State
NASA Technical Reports Server (NTRS)
Isachsen, Y. W. (Principal Investigator); Fakundiny, R. H.; Forster, S. W.
1974-01-01
The author has identified the following significant results. All ERTS-1 linears confirmed to date have topographic expression although they may appear as featureless tonal linears on the imagery. A bias is unavoidably introduced against any linears which may parallel raster lines, lithological trends, or the azimuth of solar illumination. Ground study of ERTS-1 topographic lineaments in the Adirondacks indicates: outcrops along linears are even more rare than expected, fault breccias are found along some NNE lineaments, chloritization and slickensiding without brecciation characterize one EW lineament whereas closely-spaced jointing plus a zone of plastic shear define another. Field work in the Catskills suggests that the prominent new NNE lineaments may be surface manifestations of normal faulting in the basement, and that it may become possible to map major joint sets over extensive plateau regions directly on the imagery. Fall and winter images each display some unique linears, and long linears on the fall image commonly appear as aligned segments on the winter scene. A computer-processed color composite image permitted the extraction or additional information on the shaded side of mountains.
Radiological properties of MAGIC normoxic polymer gel dosimetry
NASA Astrophysics Data System (ADS)
Aljamal, M.; Zakaria, A.; Shamsuddin, S.
2013-04-01
For a polymer gel dosimeter to be of use in radiation dosimetry, it should display water-equivalent radiological properties. In this study, the radiological properties of the MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) normoxic polymer gels were investigated. The mass density (ρ) was determined based on Archimedes' principle. The weight fraction of elemental composition and the effective atomic number (Zeff) were calculated. The electron density was also measured with 90° scattering angle at room temperature. The linear attenuation coefficient (μ) of unirradiated gel, irradiated gel, and water were determined using Am-241 based on narrow beam geometry. Monte Carlo simulation was used to calculate the depth doses response of MAGIC gel and water for 6MV photon beam. The weight fractions of elements composition of MAGIC gel were close to that for water. The mass density was found to be 1027 ± 2 kg m-3, which is also very close to mass density of muscle tissue (1030 kg m-3) and 2.7% higher than that of water. The electron density (ρe) and atomic number (Zeff) were found to be 3.43 × 1029 e m-3 and 7.105, respectively. The electron density measured was 2.6% greater than that for water. The atomic number was very close to that for water. The prepared MAGIC gel was found to be water equivalent based on the study of element composition, mass density, electron density and atomic number. The linear attenuation coefficient of unirradiated gel was very close to that of water. The μ of irradiated gel was found to be linear with dose 2-40 Gy. The depth dose response for MAGIC gel from a 6 MV photon beam had a percentage dose difference to water of less than 1%. Therefore it satisfies the criteria to be a good polymer gel dosimeter for radiotherapy.
Atomized scan strategy for high definition for VR application
NASA Astrophysics Data System (ADS)
Huang, Shuping; Ran, Feng; Ji, Yuan; Chen, Wendong
2017-10-01
Silicon-based OLED (Organic Light Emitting Display) microdisplay technology begins to attract people's attention in the emerging VR and AR devices. The high display frame refresh rate is an important solution to alleviate the dizziness in VR applications. Traditional display circuit drivers use the analog method or the digital PWM method that follow the serial scan order from the first pixel to the last pixel by using the shift registers. This paper proposes a novel atomized scan strategy based on the digital fractal scan strategy using the pseudo-random scan order. It can be used to realize the high frame refresh rate with the moderate pixel clock frequency in the high definition OLED microdisplay. The linearity of the gray level is also improved compared with the Z fractal scan strategy.
75 FR 8033 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... that posters informing workers of their rights are displayed at the site (FAR 22.406-7(b)). Contracting..., who use various methods to award contracts for good or services. One method, prescribed by Part 15 of...
Toxicity of a furanocoumarin to armyworms: a case of biosynthetic escape from insect herbivores.
Berenbaum, M
1978-08-11
When the linear furanocoumarin xanthotoxin, found in many plants of the families Rutaceae and Umbelliferae, was administered to larvae of Spodoptera eridania, a generalist insect herbivore, it displayed toxic properties lacking in its biosynthetic precursor umbelliferone. Reduced toxicity observed in the absence of ultraviolet light is consistent with the known mechanism of photoinactivation of DNA by furanocoumarins through ultraviolet-catalyzed cross-linkage of strands. Thus, the ability of a plant to convert umbelliferone to linear furanocoumarins appears to confer broader protection against insect herbivores.
Negative birefringent polyimide films
NASA Technical Reports Server (NTRS)
Harris, Frank W. (Inventor); Cheng, Stephen Z. D. (Inventor)
1994-01-01
A negative birefringent film, useful in liquid crystal displays, and a method for controlling the negative birefringence of a polyimide film is disclosed which allows the matching of an application to a targeted amount of birefringence by controlling the degree of in-plane orientation of the polyimide by the selection of functional groups within both the diamine and dianhydride segments of the polyimide which affect the polyimide backbone chain rigidity, linearity, and symmetry. The higher the rigidity, linearity and symmetry of the polyimide backbone, the larger the value of the negative birefringence of the polyimide film.
Acoustic emission linear pulse holography
Collins, H. Dale; Busse, Lawrence J.; Lemon, Douglas K.
1985-01-01
Defects in a structure are imaged as they propagate, using their emitted acoustic energy as a monitored source. Short bursts of acoustic energy propagate through the structure to a discrete element receiver array. A reference timing transducer located between the array and the inspection zone initiates a series of time-of-flight measurements. A resulting series of time-of-flight measurements are then treated as aperture data and are transferred to a computer for reconstruction of a synthetic linear holographic image. The images can be displayed and stored as a record of defect growth.
NASA Technical Reports Server (NTRS)
Fertis, D. G.; Simon, A. L.
1981-01-01
The requisite methodology to solve linear and nonlinear problems associated with the static and dynamic analysis of rotating machinery, their static and dynamic behavior, and the interaction between the rotating and nonrotating parts of an engine is developed. Linear and nonlinear structural engine problems are investigated by developing solution strategies and interactive computational methods whereby the man and computer can communicate directly in making analysis decisions. Representative examples include modifying structural models, changing material, parameters, selecting analysis options and coupling with interactive graphical display for pre- and postprocessing capability.
Reflexion on linear regression trip production modelling method for ensuring good model quality
NASA Astrophysics Data System (ADS)
Suprayitno, Hitapriya; Ratnasari, Vita
2017-11-01
Transport Modelling is important. For certain cases, the conventional model still has to be used, in which having a good trip production model is capital. A good model can only be obtained from a good sample. Two of the basic principles of a good sampling is having a sample capable to represent the population characteristics and capable to produce an acceptable error at a certain confidence level. It seems that this principle is not yet quite understood and used in trip production modeling. Therefore, investigating the Trip Production Modelling practice in Indonesia and try to formulate a better modeling method for ensuring the Model Quality is necessary. This research result is presented as follows. Statistics knows a method to calculate span of prediction value at a certain confidence level for linear regression, which is called Confidence Interval of Predicted Value. The common modeling practice uses R2 as the principal quality measure, the sampling practice varies and not always conform to the sampling principles. An experiment indicates that small sample is already capable to give excellent R2 value and sample composition can significantly change the model. Hence, good R2 value, in fact, does not always mean good model quality. These lead to three basic ideas for ensuring good model quality, i.e. reformulating quality measure, calculation procedure, and sampling method. A quality measure is defined as having a good R2 value and a good Confidence Interval of Predicted Value. Calculation procedure must incorporate statistical calculation method and appropriate statistical tests needed. A good sampling method must incorporate random well distributed stratified sampling with a certain minimum number of samples. These three ideas need to be more developed and tested.
Rabin, Alon; Portnoy, Sigal; Kozol, Zvi
2016-11-01
Rabin, A, Portnoy, S, and Kozol, Z. The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test. J Strength Cond Res 30(11): 3204-3211, 2016-Altered movement patterns including contralateral pelvic drop, increased hip adduction, knee abduction, and external rotation have been previously implicated in several lower extremity pathologies. Although various methods exist for assessing movement patterns, real-time visual observation is the most readily available method. The purpose of this study was to determine whether differing visual ratings of trunk, pelvis, and knee alignment, as well as overall quality of movement, are associated with differences in 3-dimensional trunk, pelvis, hip, or knee kinematics during a lateral step down test. Trunk, pelvis, and knee alignment of 30 healthy participants performing the lateral step down were visually rated as "good" or "faulty" based on previously established criteria. An additional categorization of overall quality of movement as either good or moderate was performed based on the aggregate score of each individual rating criterion. Three-dimensional motion analysis of trunk, pelvis, hip, and knee kinematics was simultaneously performed. A faulty pelvis alignment displayed a greater peak contralateral pelvic drop (effect size [ES], 1.65; p < 0.01) and a greater peak hip adduction (ES: 1.04, p = 0.01) compared with participants with a good pelvis alignment. Participants with a faulty knee alignment displayed greater peak knee external rotation compared with participants with a good knee alignment (ES, 0.78; p = 0.02). Participants with an overall moderate quality of movement displayed increased peak contralateral pelvic drop (ES, 1.07; p = 0.01) and peak knee external rotation (ES, 0.72; p = 0.04) compared with those with an overall good quality of movement. Visual rating of quality of movement during a lateral step down test, as performed by an experienced physical therapist, is associated with differences in several kinematics previously implicated in various pathologies.
A Low-Cost Real Color Picker Based on Arduino
Agudo, Juan Enrique; Pardo, Pedro J.; Sánchez, Héctor; Pérez, Ángel Luis; Suero, María Isabel
2014-01-01
Color measurements have traditionally been linked to expensive and difficult to handle equipment. The set of mathematical transformations that are needed to transfer a color that we observe in any object that doesn't emit its own light (which is usually called a color-object) so that it can be displayed on a computer screen or printed on paper is not at all trivial. This usually requires a thorough knowledge of color spaces, colorimetric transformations and color management systems. The TCS3414CS color sensor (I2C Sensor Color Grove), a system for capturing, processing and color management that allows the colors of any non-self-luminous object using a low-cost hardware based on Arduino, is presented in this paper. Specific software has been developed in Matlab and a study of the linearity of chromatic channels and accuracy of color measurements for this device has been undertaken. All used scripts (Arduino and Matlab) are attached as supplementary material. The results show acceptable accuracy values that, although obviously do not reach the levels obtained with the other scientific instruments, for the price difference they present a good low cost option. PMID:25004152
Xu, Jian; Sun, Shaobo; Li, Qian; Yue, Ying; Li, Yingdong; Shao, Shijun
2014-11-07
A novel probe incorporating quaternized 4-pyridinium group into a BODIPY molecule was synthesized and studied for the selective detection of fluoride ions (F(-)) in aqueous solution. The design was based on a fluoride-specific desilylation reaction and the "Turn-On" fluorescent response of probe 1 to F(-) was ascribed to the inhibition of photoinduced electron transfer (PET) process. The probe displayed many desired properties such as high specificity, appreciable solubility, desirable response time and low toxicity to mammalian cells. There was a good linearity between the fluorescence intensity and the concentrations of F(-) in the range of 0.1-1mM with a detection limit of 0.02 mM. The sensing mechanism was confirmed by the NMR, electrospray ionization mass spectrum, optical spectroscopy and the mechanism of "Turn-On" fluorescent response was also determinated by a density functional theory (DFT) calculation using Gaussian 03 program. Moreover, the probe was successfully applied for the fluorescence imaging of F(-) in human epithelial lung cancer (A549) cells and alveolar type II (ATII) cells under physiological conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Yang; Ma, Zhong-Ying; Zhang, De-Long; Deng, Jia-Li; Chen, Xiong; Xie, Cheng-Zhi; Qiao, Xin; Li, Qing-Zhong; Xu, Jing-Yuan
2018-04-15
A new aluminum ion fluorescent probe (4-(diethylamino)-2-hydroxybenzylidene)isoquinoline-1-carbohydrazide (HL 1 ) has been conveniently synthesized and characterized. HL 1 exhibited a highly selective and pronounced enhancement for Al 3+ in the fluorescence emission over other common cations by forming a 2:1 complex, with a recognition mechanism based on excited-state intramolecular proton transfer (ESIPT) and intramolecular charge transfer (ICT). The strong fluorescent emission can be observed even at ppm level concentration of the probe in the presence of Al 3+ with 41 fold intensity enhancement at 545 nm. HL 1 displays good linear relationship with Al 3+ in the low concentration and the limit of detection is 8.08 × 10 -8 mol/L. Similar molecules with different substituents on salicylaldehyde phenyl ring were synthesized for studying the structure-activity relationship. Density-functional theory (DFT) calculations are in agreement with the proposed mechanism. It is confirmed that HL 1 could be used to detect Al 3+ ions in real sample by fluorescence spectrometry and Al 3+ ions in cells by bioimaging. Copyright © 2018 Elsevier B.V. All rights reserved.
Evaluation of various molecular parameters as predictors of bioconcentration in fish
DOE Office of Scientific and Technical Information (OSTI.GOV)
Connell, D.W.; Schueuermann G3
1988-06-01
A reliable set of data on the bioconcentration factors (KB) of a diverse range of compounds in fish was selected from the literature. Using the structures of these compounds, the following molecular parameters were calculated: molecular weight (MW), solvent accessible molecular surface area (SASA), solvent accessible molecular volume (SAV), molar refraction (MR), largest principal moment of inertia (LPMI) and several molecular connectivity indices of the Randic type (1 chi, 2 chi, 3 chi, 1 chi vr, 3 chi c). The relationships between these parameters and log KB were evaluated for all compounds and the following subgroups: chlorinated hydrocarbons (CHC), polyaromaticmore » hydrocarbons (PAH), and CHC and PAH combined. These relationships indicated that SASA, SAV, and MR were good predictors of log KB for the CHC and PAH combined or alone and the other parameters were less satisfactory with these groups. In addition with the CHC, the log of these parameters displayed an improved correlation with log KB due to apparent nonlinearity in the log to linear relationship. Thus, with these groups of compounds, calculated values of SASA, SAV, and MR provide a satisfactory means of estimating log KB without measured data.« less
Two low-cost digital camera-based platforms for quantitative creatinine analysis in urine.
Debus, Bruno; Kirsanov, Dmitry; Yaroshenko, Irina; Sidorova, Alla; Piven, Alena; Legin, Andrey
2015-10-01
In clinical analysis creatinine is a routine biomarker for the assessment of renal and muscular dysfunctions. Although several techniques have been proposed for a fast and accurate quantification of creatinine in human serum or urine, most of them require expensive or complex apparatus, advanced sample preparation or skilled operators. To circumvent these issues, we propose two home-made platforms based on a CD Spectroscope (CDS) and Computer Screen Photo-assisted Technique (CSPT) for the rapid assessment of creatinine level in human urine. Both systems display a linear range (r(2) = 0.9967 and 0.9972, respectively) from 160 μmol L(-1) to 1.6 mmol L(-1) for standard creatinine solutions (n = 15) with respective detection limits of 89 μmol L(-1) and 111 μmol L(-1). Good repeatability was observed for intra-day (1.7-2.9%) and inter-day (3.6-6.5%) measurements evaluated on three consecutive days. The performance of CDS and CSPT was also validated in real human urine samples (n = 26) using capillary electrophoresis data as reference. Corresponding Partial Least-Squares (PLS) regression models provided for mean relative errors below 10% in creatinine quantification. Copyright © 2015 Elsevier B.V. All rights reserved.
A simple preparation of graphite/gelatin composite for electrochemical detection of dopamine.
Rajkumar, Chellakannu; Thirumalraj, Balamurugan; Chen, Shen-Ming; Chen, His-An
2017-02-01
In this study, we demonstrate a simple preparation of graphite (GR) sheets assisted with gelatin (GLN) polypeptide composite was developed for sensitive detection of dopamine (DA) sensor. The GR/GLN composite was prepared by GR powder in GLN solution (5mg/mL) via sonication process. The prepared GR/GLN composite displays well dispersion ability in biopolymer matrix and characterized via scanning electron microscope (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS) studies. The GR/GLN modified electrode showed an excellent electrocatalytic activity toward the oxidation of DA, suggesting that the successful formation of GR sheets crosslinked with the functional groups of GLN polypeptide. In addition, the GR/GLN modified electrode achieved a wide linear response ranging from 0.05 to 79.5μM with a detection limit of 0.0045μM. The calculated analytical sensitivity of the sensor was 1.36±0.02μAμM -1 cm -2 . Conversely, the modified electrode demonstrates a good storage stability, reproducibility and repeatability. In addition, the sensor manifests the determination of DA in human serum and urine samples for practical applications. Copyright © 2016 Elsevier Inc. All rights reserved.
A facile route to glycated albumin detection.
Bohli, Nadra; Meilhac, Olivier; Rondeau, Philippe; Gueffrache, Syrine; Mora, Laurence; Abdelghani, Adnane
2018-07-01
In this paper we propose an easy way to detect the glycated form of human serum albumin which is biomarker for several diseases such as diabetes and Alzheimer. The detection platform is a label free impedimetric immunosensor, in which we used a monoclonal human serum albumin antibody as a bioreceptor and electrochemical impedance as a transducing method. The antibody was deposited onto a gold surface by simple physisorption technique. Bovine serum albumin was used as a blocking agent for non-specific binding interactions. Cyclic voltammetry and electrochemical impedance spectroscopy were used for the characterization of each layer. Human serum albumin was glycated at different levels with several concentrations of glucose ranging from 0 mM to 500 mM representing physiological, pathological (diabetic albumin) and suprapathological concentration of glucose. Through the calibration curves, we could clearly distinguish between two different areas related to physiological and pathological albumin glycation levels. The immunosensor displayed a linear range from 7.49% to 15.79% of glycated albumin to total albumin with a good sensitivity. Surface plasmon resonance imaging was also used to characterize the developed immunosensor. Copyright © 2018 Elsevier B.V. All rights reserved.
Chen, Pei-Yen; Luo, Chin-Hsiang; Chen, Mei-Chin; Tsai, Feng-Jie; Chang, Nai-Fang; Shih, Ying
2011-01-01
Cobalt phthalocyanine (CoPc) films were deposited on the surface of a screen-printed carbon electrode using a simple drop coating method. The cyclic voltammogram of the resulting CoPc modified screen-printed electrode (CoPc/SPE) prepared under optimum conditions shows a well-behaved redox couple due to the (CoI/CoII) system. The CoPc/SPE surface demonstrates excellent electrochemical activity towards the oxidation of sulfur in a 0.01 mol·L−1 NaOH. A linear calibration curve with the detection limit (DL, S/N = 3) of 0.325 mg·L−1 was achieved by CoPc/SPE coupled with flow injection analysis of the sulfur concentration ranging from 4 to 1120 mg·L−1. The precision of the system response was evaluated (3.60% and 3.52% RSD for 12 repeated injections), in the range of 64 and 480 mg·L−1 sulfur. The applicability of the method was successfully demonstrated in a real sample analysis of sulfur in anti-acne creams, and good recovery was obtained. The CoPc/SPE displayed several advantages in sulfur determination including easy fabrication, high stability, and low cost. PMID:21747708
Boronic acid based imprinted electrochemical sensor for rutin recognition and detection.
Wang, Chunlei; Wang, Qi; Zhong, Min; Kan, Xianwen
2016-10-21
Multi-walled carbon nanotubes (MWNTs) and boronic acid based molecular imprinting polymer (MIP) were successively modified on a glassy carbon electrode surface to fabricate a novel electrochemical sensor for rutin recognition and detection. 3-Aminophenylboronic acid (APBA) was chosen as a monomer for the electropolymerization of MIP film in the presence of rutin. In addition to the imprinted cavities in MIP film to complement the template molecule in shape and functional groups, the high affinity between the boronic acid group of APBA and vicinal diols of rutin also enhanced the selectivity of the sensor, which made the sensor display a good selectivity to rutin. Moreover, the modified MWNTs improved the sensitivity of the sensor for rutin detection. The mole ratios of rutin and APBA, electropolymerized scan cycles and rates, and pH value of the detection solution were optimized. Under optimal conditions, the sensor was used to detect rutin in a linear range from 4.0 × 10 -7 to 1.0 × 10 -5 mol L -1 with a detection limit of 1.1 × 10 -7 mol L -1 . The sensor has also been applied to assay rutin in tablets with satisfactory results.
Intermolecular cope-type hydroamination of alkenes and alkynes using hydroxylamines.
Moran, Joseph; Gorelsky, Serge I; Dimitrijevic, Elena; Lebrun, Marie-Eve; Bédard, Anne-Catherine; Séguin, Catherine; Beauchemin, André M
2008-12-31
The development of the Cope-type hydroamination as a method for the metal- and acid-free intermolecular hydroamination of hydroxylamines with alkenes and alkynes is described. Aqueous hydroxylamine reacts efficiently with alkynes in a Markovnikov fashion to give oximes and with strained alkenes to give N-alkylhydroxylamines, while unstrained alkenes are more challenging. N-Alkylhydroxylamines also display similar reactivity with strained alkenes and give modest to good yields with vinylarenes. Electron-rich vinylarenes lead to branched products while electron-deficient vinylarenes give linear products. A beneficial additive effect is observed with sodium cyanoborohydride, the extent of which is dependent on the structure of the hydroxylamine. The reaction conditions are found to be compatible with common protecting groups, free OH and NH bonds, as well as bromoarenes. Both experimental and theoretical results suggest the proton transfer step of the N-oxide intermediate is of vital importance in the intermolecular reactions of alkenes. Details are disclosed concerning optimization, reaction scope, limitations, and theoretical analysis by DFT, which includes a detailed molecular orbital description for the concerted hydroamination process and an exhaustive set of calculated potential energy surfaces for the reactions of various alkenes, alkynes, and hydroxylamines.
Koppenhaver, Shane L.; Fritz, Julie M.; Hebert, Jeffrey J.; Kawchuk, Greg N.; Parent, Eric C.; Gill, Norman W.; Childs, John D.; Teyhen, Deydre S.
2012-01-01
Understanding the clinical characteristics of patients with low back pain (LBP) who display improved lumbar multifidus (LM) muscle function after spinal manipulative therapy (SMT) may provide insight into a potentially synergistic interaction between SMT and exercise. Therefore, the purpose of this study was to identify the baseline historical and physical examination factors associated with increased contracted LM muscle thickness one week after SMT. Eighty-one participants with LBP underwent a baseline physical examination and ultrasound imaging assessment of the LM muscle during submaximal contraction before and one week after SMT. The relationship between baseline examination variables and 1-week change in contracted LM thickness was assessed using correlation analysis and hierarchical multiple linear regression. Four variables best predicted the magnitude of increases in contracted LM muscle thickness after SMT. When combined, these variables suggest that patients with LBP, (1) that are fairly acute, (2) have at least a moderately good prognosis without focal and irritable symptoms, and (3) exhibit signs of spinal instability, may be the best candidates for a combined SMT and LSE treatment approach. PMID:22516351
Koppenhaver, Shane L; Fritz, Julie M; Hebert, Jeffrey J; Kawchuk, Greg N; Parent, Eric C; Gill, Norman W; Childs, John D; Teyhen, Deydre S
2012-10-01
Understanding the clinical characteristics of patients with low back pain (LBP) who display improved lumbar multifidus (LM) muscle function after spinal manipulative therapy (SMT) may provide insight into a potentially synergistic interaction between SMT and exercise. Therefore, the purpose of this study was to identify the baseline historical and physical examination factors associated with increased contracted LM muscle thickness one week after SMT. Eighty-one participants with LBP underwent a baseline physical examination and ultrasound imaging assessment of the LM muscle during submaximal contraction before and one week after SMT. The relationship between baseline examination variables and 1-week change in contracted LM thickness was assessed using correlation analysis and hierarchical multiple linear regression. Four variables best predicted the magnitude of increases in contracted LM muscle thickness after SMT. When combined, these variables suggest that patients with LBP, (1) that are fairly acute, (2) have at least a moderately good prognosis without focal and irritable symptoms, and (3) exhibit signs of spinal instability, may be the best candidates for a combined SMT and lumbar stabilization exercise (LSE) treatment approach. Published by Elsevier Ltd.
A low-cost real color picker based on Arduino.
Agudo, Juan Enrique; Pardo, Pedro J; Sánchez, Héctor; Pérez, Ángel Luis; Suero, María Isabel
2014-07-07
Color measurements have traditionally been linked to expensive and difficult to handle equipment. The set of mathematical transformations that are needed to transfer a color that we observe in any object that doesn't emit its own light (which is usually called a color-object) so that it can be displayed on a computer screen or printed on paper is not at all trivial. This usually requires a thorough knowledge of color spaces, colorimetric transformations and color management systems. The TCS3414CS color sensor (I2C Sensor Color Grove), a system for capturing, processing and color management that allows the colors of any non-self-luminous object using a low-cost hardware based on Arduino, is presented in this paper. Specific software has been developed in Matlab and a study of the linearity of chromatic channels and accuracy of color measurements for this device has been undertaken. All used scripts (Arduino and Matlab) are attached as supplementary material. The results show acceptable accuracy values that, although obviously do not reach the levels obtained with the other scientific instruments, for the price difference they present a good low cost option.
Vilian, A T Ezhil; Chen, Shen-Ming; Chen, Ying-Hui; Ali, M Ajmal; Al-Hemaid, Fahad M A
2014-06-01
The present work describes the characterization of a chemically reduced graphene oxide (CRGO) modified glassy carbon electrode (GCE) for electrochemical investigation of caffeic acid (CA). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), amperometry, and electrochemical impedance spectroscopy (EIS) techniques were used to characterize the properties of the electrode. There was an obvious enhancement of the current response and a decreased over potential for the oxidation of CA. The interfacial electron transfer rate of CA was studied by EIS. Under optimal conditions, the CRGO displayed a linear response range of 1×10(-8) to 8×10(-4) M and the detection limit was 2×10(-9) M (S/N=3), with a sensitivity of 192.21 μA mM(-1) cm(-2) at an applied potential of +0.2V (vs. Ag/AgCl reference), which suggests that the CRGO is a promising sensing materials for the electrochemical investigation of CA. The results showed the good sensitivity, selectivity and high reproducibility of the CRGO modified electrode. Moreover, this modified electrode was further applied to investigate the CA in real samples of wine with satisfactory results. Copyright © 2014 Elsevier Inc. All rights reserved.
Lin, Donghai; Tang, Thompson; Jed Harrison, D; Lee, William E; Jemere, Abebaw B
2015-06-15
We report on the development of a regenerable sensitive immunosensor based on electrochemical impedance spectroscopy for the detection of type 5 adenovirus. The multi-layered immunosensor fabrication involved successive modification steps on gold electrodes: (i) modification with self-assembled layer of 1,6-hexanedithiol to which gold nanoparticles were attached via the distal thiol groups, (ii) formation of self-assembled monolayer of 11-mercaptoundecanoic acid onto the gold nanoparticles, (iii) covalent immobilization of monoclonal anti-adenovirus 5 antibody, with EDC/NHS coupling reaction on the nanoparticles, completing the immunosensor. The immunosensor displayed a very good detection limit of 30 virus particles/ml and a wide linear dynamic range of 10(5). An electrochemical reductive desorption technique was employed to completely desorb the components of the immunosensor surface, then re-assemble the sensing layer and reuse the sensor. On a single electrode, the multi-layered immunosensor could be assembled and disassembled at least 30 times with 87% of the original signal intact. The changes of electrode behavior after each assembly and desorption processes were investigated by cyclic voltammetry, electrochemical impedance spectroscopy and X-ray photoelectron spectroscopy techniques. Copyright © 2014 Elsevier B.V. All rights reserved.
Luo, X; Huang, M; He, D; Wang, M; Zhang, Y; Jiang, P
2018-05-29
High electrical conductivity and the exposure to more active sites are crucial to boost the performance of a glucose sensor. A porous binary metal oxide nanoarray integrated on a binder-free 3D electrode is expected to offer a highly sensitive sensing platform. As a model, porous NiCo2O4 nanowire arrays supported on carbon cloth (NiCo2O4 NWA/CC) have been prepared and used for enzyme-free glucose sensing. NiCo2O4 NWA/CC shows larger effective surface area, superior electronic conductivity, and higher catalytic activity towards enzyme-free glucose sensing, with a linear range from 1 μM to 0.63 mM, a sensitivity of 4.12 mA mM-1 cm-2, and low detection limit of 0.5 μM. Moreover, NiCo2O4 NWA/CC also displays good selectivity and stability and thus, it can be reliable for glucose detection in human serum samples. These findings inspire the fabrication of a high-performance electrochemical sensing platform by preparing porous binary metal oxide nanoarrays supported on a 3D conductive substrate.
The hubris hypothesis: The downside of comparative optimism displays.
Hoorens, Vera; Van Damme, Carolien; Helweg-Larsen, Marie; Sedikides, Constantine
2017-04-01
According to the hubris hypothesis, observers respond more unfavorably to individuals who express their positive self-views comparatively than to those who express their positive self-views non-comparatively, because observers infer that the former hold a more disparaging view of others and particularly of observers. Two experiments extended the hubris hypothesis in the domain of optimism. Observers attributed less warmth (but not less competence) to, and showed less interest in affiliating with, an individual displaying comparative optimism (the belief that one's future will be better than others' future) than with an individual displaying absolute optimism (the belief that one's future will be good). Observers responded differently to individuals displaying comparative versus absolute optimism, because they inferred that the former held a gloomier view of the observers' future. Consistent with previous research, observers still attributed more positive traits to a comparative or absolute optimist than to a comparative or absolute pessimist. Copyright © 2016. Published by Elsevier Inc.
Exploring Growth Trajectories of Problem Behavior in Young Children
ERIC Educational Resources Information Center
McCaffrey, Bethany L.
2012-01-01
Given the negative outcomes associated with problem behavior and the heightened risk for children with disabilities to display problematic behavior, the current study implemented hierarchical linear modeling to explore the growth trajectories of problem behavior in a nationally representative sample of preschool children with disabilities. Results…
The patient satisfaction questionnaire of EUprimecare project: measurement properties.
Cimas, Marta; Ayala, Alba; García-Pérez, Sonia; Sarria-Santamera, Antonio; Forjaz, Maria João
2016-06-01
The measurement of patient satisfaction is considered an essential outcome indicator to evaluate health care quality. Patient satisfaction is considered a multi-dimensional construct, which would include a variety of domains. Although a large number of studies have proposed scales to measure patient satisfaction, there is a lack of psychometric information on them. This study aims to describe the psychometric properties of the Primary Care Satisfaction Scale (PCSS) of the EUprimecare project. A cross-sectional survey of patient satisfaction with primary care was carried out by telephone interview. Primary care services of Estonia, Finland, Germany, Hungary, Lithuania, Italy and Spain. A total of 3020 adult patients aged 18-65 years old attending primary care services. Classic psychometric properties were analysed and Rasch analysis was used to assess the following measurement properties: fit to the Rasch model; uni-dimensionality; reliability; differential item functioning (DIF) by gender, age, civil status, area of residency and country; local independency; adequacy of response scale; and scale targeting. To achieve good fit to the Rasch model, the original response scales of three items (1, 2 and 6) were rescored and Item 3 (waiting time in the room) was removed. The scale was uni-dimensional and Person Separation Index was 0.79, indicating a good reliability. All items were free from bias. PCSS linear measure displayed satisfactory convergent validity with overall satisfaction with primary care. PCSS, as a reliable and valid scale, could be used to measure patient satisfaction in primary care in Europe. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.
Moreno, Megan A; Kacvinsky, Lauren; Pumper, Megan; Wachowski, Leah; Whitehill, Jennifer M.
2013-01-01
Background Mifflin Street Block Party is a yearly Wisconsin event known for high levels of alcohol consumption and previous negative outcomes. This study investigated displayed Mifflin references on Facebook and their association with alcohol consumption at Mifflin. Methods Participants included first-year college students who were enrolled in a longitudinal study involving Facebook profile assessments and interviews. We identified a subset of participants who were interviewed within 28 days following Mifflin. Participants were categorized as “Mifflin Displayers” or “Non-Displayers” based on Facebook profile content. Interviews included the TimeLine FollowBack to assess alcohol use in the past 28 days. Analysis included logistic and linear regression. Results Among the 66 participants included in this study, 45 (68.2%) were female and 38 (50%) were Mifflin Displayers on Facebook. Among the Mifflin Displayer participants, 18 (27.2%) displayed prior to Mifflin, 11 displayed the day of Mifflin (16.7%) and 19 (28.8%) displayed after. Some participants displayed in more than one time frame. A total of 40 (60.6%) reported alcohol use on the day of the Mifflin Street Block party. The mean number of drinks reported on the day of Mifflin was 8.8 (SD=6.1), with a range of 1 to 35. Displayed references to Mifflin on Facebook were positively associated with reporting alcohol use at Mifflin (OR=20.9, 95% CI 5.6–78.8). Discussion Displaying Facebook references to Mifflin was associated with alcohol consumption on the day of the event. Future prevention efforts could consider creating Facebook advertisements with safety messages triggered by Mifflin displays. PMID:24511865
Cooperation among cancer cells as public goods games on Voronoi networks.
Archetti, Marco
2016-05-07
Cancer cells produce growth factors that diffuse and sustain tumour proliferation, a form of cooperation that can be studied using mathematical models of public goods in the framework of evolutionary game theory. Cell populations, however, form heterogeneous networks that cannot be described by regular lattices or scale-free networks, the types of graphs generally used in the study of cooperation. To describe the dynamics of growth factor production in populations of cancer cells, I study public goods games on Voronoi networks, using a range of non-linear benefits that account for the known properties of growth factors, and different types of diffusion gradients. The results are surprisingly similar to those obtained on regular graphs and different from results on scale-free networks, revealing that network heterogeneity per se does not promote cooperation when public goods diffuse beyond one-step neighbours. The exact shape of the diffusion gradient is not crucial, however, whereas the type of non-linear benefit is an essential determinant of the dynamics. Public goods games on Voronoi networks can shed light on intra-tumour heterogeneity, the evolution of resistance to therapies that target growth factors, and new types of cell therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Singapore Language Enhancer: Identity Included
ERIC Educational Resources Information Center
Wee, Desmond
2009-01-01
This article explores the rhetoric of the four official languages (English, Mandarin, Malay and Tamil) in Singapore and the domestic aversion towards Chinese "dialects" and colloquial "Singlish". The "Speak Mandarin Campaign" alongside the "Speak Good English Movement" represent a display of intercultural…
An approach for designing flight symbology
DOT National Transportation Integrated Search
2004-09-29
The goals of this effort are to identify features of navigation symbology that are problematic when presented on electronic displays and to develop a method to design and evaluate good symbology that takes into account the different platforms on whic...
Urban, Johannes H; Moosmeier, Markus A; Aumüller, Tobias; Thein, Marcus; Bosma, Tjibbe; Rink, Rick; Groth, Katharina; Zulley, Moritz; Siegers, Katja; Tissot, Kathrin; Moll, Gert N; Prassler, Josef
2017-11-15
Ribosomally synthesized and post-translationally modified peptides (RiPPs) are an emerging class of natural products with drug-like properties. To fully exploit the potential of RiPPs as peptide drug candidates, tools for their systematic engineering are required. Here we report the engineering of lanthipeptides, a subclass of RiPPs characterized by multiple thioether cycles that are enzymatically introduced in a regio- and stereospecific manner, by phage display. This was achieved by heterologous co-expression of linear lanthipeptide precursors fused to the widely neglected C-terminus of the bacteriophage M13 minor coat protein pIII, rather than the conventionally used N-terminus, along with the modifying enzymes from distantly related bacteria. We observe that C-terminal precursor peptide fusions to pIII are enzymatically modified in the cytoplasm of the producing cell and subsequently displayed as mature cyclic peptides on the phage surface. Biopanning of large C-terminal display libraries readily identifies artificial lanthipeptide ligands specific to urokinase plasminogen activator (uPA) and streptavidin.
Aligning the unalignable: bacteriophage whole genome alignments.
Bérard, Sèverine; Chateau, Annie; Pompidor, Nicolas; Guertin, Paul; Bergeron, Anne; Swenson, Krister M
2016-01-13
In recent years, many studies focused on the description and comparison of large sets of related bacteriophage genomes. Due to the peculiar mosaic structure of these genomes, few informative approaches for comparing whole genomes exist: dot plots diagrams give a mostly qualitative assessment of the similarity/dissimilarity between two or more genomes, and clustering techniques are used to classify genomes. Multiple alignments are conspicuously absent from this scene. Indeed, whole genome aligners interpret lack of similarity between sequences as an indication of rearrangements, insertions, or losses. This behavior makes them ill-prepared to align bacteriophage genomes, where even closely related strains can accomplish the same biological function with highly dissimilar sequences. In this paper, we propose a multiple alignment strategy that exploits functional collinearity shared by related strains of bacteriophages, and uses partial orders to capture mosaicism of sets of genomes. As classical alignments do, the computed alignments can be used to predict that genes have the same biological function, even in the absence of detectable similarity. The Alpha aligner implements these ideas in visual interactive displays, and is used to compute several examples of alignments of Staphylococcus aureus and Mycobacterium bacteriophages, involving up to 29 genomes. Using these datasets, we prove that Alpha alignments are at least as good as those computed by standard aligners. Comparison with the progressive Mauve aligner - which implements a partial order strategy, but whose alignments are linearized - shows a greatly improved interactive graphic display, while avoiding misalignments. Multiple alignments of whole bacteriophage genomes work, and will become an important conceptual and visual tool in comparative genomics of sets of related strains. A python implementation of Alpha, along with installation instructions for Ubuntu and OSX, is available on bitbucket (https://bitbucket.org/thekswenson/alpha).
NASA Astrophysics Data System (ADS)
Satvekar, R. K.; Rohiwal, S. S.; Tiwari, A. P.; Raut, A. V.; Tiwale, B. M.; Pawar, S. H.
2015-01-01
A novel strategy to fabricate hydrogen peroxide third generation biosensor has been developed from sol-gel of silica/chitosan (SC) organic-inorganic hybrid material assimilated with iron oxide magnetic nanoparticles (Fe3O4). The large surface area of Fe3O4 and porous morphology of the SC composite facilitates a high loading of horseradish peroxidase (HRP). Moreover, the entrapped enzyme preserves its conformation and biofunctionality. The fabrication of hydrogen peroxide biosensor has been carried out by drop casting of the SC/F/HRP nanocomposite on glassy carbon electrode (GCE) for study of direct electrochemistry. The x-ray diffraction (XRD) pattern and transmission electron microscopy (TEM) confirms the phase purity and particle size of as-synthesized Fe3O4 nanoparticles, respectively. The nanocomposite was characterized by UV-vis spectroscopy, fluorescence spectroscopy and Fourier transform infrared (FTIR) for the characteristic structure and conformation of enzyme. The surface topographies of the nanocomposite thin films were investigated by scanning electron microscopy (SEM). Dynamic light scattering (DLS) was used to determine the particle size distribution. The electrostatic interactions of the SC composite with Fe3O4 nanoparticles were studied by the zeta potential measurement. Electrochemical impedance spectroscopy (EIS) of the SC/F/HRP/GCE electrode displays Fe3O4 nanoparticles as an excellent candidate for electron transfer. The SC/F/HRP/GCE exhibited a pair of well-defined quasi reversible cyclic voltammetry peaks due to the redox couple of HRP-heme Fe (III)/Fe (II) in pH 7.0 potassium phosphate buffer. The biosensor was employed to detect H2O2 with linear range of 5 μM to 40 μM and detection limit of 5 μM. The sensor displays excellent selectivity, sensitivity, good reproducibility and long term stability.
The Bear Went Over the Mountain: Soviet Combat Tactics in Afghanistan,
1996-08-01
spin out of control and out of Moscow’s orbit. The Soviet Politburo moved to stabilize the situation. On 27 December 1979, Moscow struck with a Coup de ...like a good idea , however, this was the dread stroevoy smotr [ceremonial inspection] which was an unwelcome part of peace-time, garrison sol- diering...and displays would be aligned with pieces of string. The process could take three days. Although inspections are good ideas , these massive formal
Competition Experiments as a Means of Evaluating Linear Free Energy Relationships
ERIC Educational Resources Information Center
Mullins, Richard J.; Vedernikov, Andrei; Viswanathan, Rajesh
2004-01-01
The use of competition experiments as a means of evaluating linear free energy relationship in the undergraduate teaching laboratory is reported. The use of competition experiments proved to be a reliable method for the construction of Hammett plots with good correlation providing great flexibility with regard to the compounds and reactions that…
NASA Astrophysics Data System (ADS)
Chesterman, Frédérique; Manssens, Hannah; Morel, Céline; Serrell, Guillaume; Piepers, Bastian; Kimpe, Tom
2017-03-01
Medical displays for primary diagnosis are calibrated to the DICOM GSDF1 but there is no accepted standard today that describes how display systems for medical modalities involving color should be calibrated. Recently the Color Standard Display Function3,4 (CSDF), a calibration using the CIEDE2000 color difference metric to make a display as perceptually linear as possible has been proposed. In this work we present the results of a first observer study set up to investigate the interpretation accuracy of a rainbow color scale when a medical display is calibrated to CSDF versus DICOM GSDF and a second observer study set up to investigate the detectability of color differences when a medical display is calibrated to CSDF, DICOM GSDF and sRGB. The results of the first study indicate that the error when interpreting a rainbow color scale is lower for CSDF than for DICOM GSDF with statistically significant difference (Mann-Whitney U test) for eight out of twelve observers. The results correspond to what is expected based on CIEDE2000 color differences between consecutive colors along the rainbow color scale for both calibrations. The results of the second study indicate a statistical significant improvement in detecting color differences when a display is calibrated to CSDF compared to DICOM GSDF and a (non-significant) trend indicating improved detection for CSDF compared to sRGB. To our knowledge this is the first work that shows the added value of a perceptual color calibration method (CSDF) in interpreting medical color images using the rainbow color scale. Improved interpretation of the rainbow color scale may be beneficial in the area of quantitative medical imaging (e.g. PET SUV, quantitative MRI and CT and doppler US), where a medical specialist needs to interpret quantitative medical data based on a color scale and/or detect subtle color differences and where improved interpretation accuracy and improved detection of color differences may contribute to a better diagnosis. Our results indicate that for diagnostic applications involving both grayscale and color images, CSDF should be chosen over DICOM GSDF and sRGB as it assures excellent detection for color images and at the same time maintains DICOM GSDF for grayscale images.
Bahreyni Toossi, Mohammad Taghi; Momennezhad, Mehdi; Hashemi, Seyed Mohammad
2012-01-01
Aim Exact knowledge of dosimetric parameters is an essential pre-requisite of an effective treatment in radiotherapy. In order to fulfill this consideration, different techniques have been used, one of which is Monte Carlo simulation. Materials and methods This study used the MCNP-4Cb to simulate electron beams from Neptun 10 PC medical linear accelerator. Output factors for 6, 8 and 10 MeV electrons applied to eleven different conventional fields were both measured and calculated. Results The measurements were carried out by a Wellhofler-Scanditronix dose scanning system. Our findings revealed that output factors acquired by MCNP-4C simulation and the corresponding values obtained by direct measurements are in a very good agreement. Conclusion In general, very good consistency of simulated and measured results is a good proof that the goal of this work has been accomplished. PMID:24377010
Fast secant methods for the iterative solution of large nonsymmetric linear systems
NASA Technical Reports Server (NTRS)
Deuflhard, Peter; Freund, Roland; Walter, Artur
1990-01-01
A family of secant methods based on general rank-1 updates was revisited in view of the construction of iterative solvers for large non-Hermitian linear systems. As it turns out, both Broyden's good and bad update techniques play a special role, but should be associated with two different line search principles. For Broyden's bad update technique, a minimum residual principle is natural, thus making it theoretically comparable with a series of well known algorithms like GMRES. Broyden's good update technique, however, is shown to be naturally linked with a minimum next correction principle, which asymptotically mimics a minimum error principle. The two minimization principles differ significantly for sufficiently large system dimension. Numerical experiments on discretized partial differential equations of convection diffusion type in 2-D with integral layers give a first impression of the possible power of the derived good Broyden variant.
Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence
NASA Astrophysics Data System (ADS)
Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas
2007-02-01
Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.
Nonlinear dynamics and cavity cooling of levitated nanoparticles
NASA Astrophysics Data System (ADS)
Fonseca, P. Z. G.; Aranas, E. B.; Millen, J.; Monteiro, T. S.; Barker, P. F.
2016-09-01
We investigate a dynamic nonlinear optomechanical system, comprising a nanosphere levitated in a hybrid electro-optical trap. An optical cavity offers readout of both linear-in-position and quadratic-in-position (nonlinear) light-matter coupling, whilst simultaneously cooling the nanosphere, for indefinite periods of time and in high vacuum. Through the rich sideband structure displayed by the cavity output we can observe cooling of the linear and non-linear particle's motion. Here we present an experimental setup which allows full control over the cavity resonant frequencies, and shows cooling of the particle's motion as a function of the detuning. This work paves the way to strong-coupled quantum dynamics between a cavity and a mesoscopic object largely decoupled from its environment.
Charge tuning of nonresonant magnetoexciton phonon interactions in graphene.
Rémi, Sebastian; Goldberg, Bennett B; Swan, Anna K
2014-02-07
Far from resonance, the coupling of the G-band phonon to magnetoexcitons in single layer graphene displays kinks and splittings versus filling factor that are well described by Pauli blocking and unblocking of inter- and intra-Landau level transitions. We explore the nonresonant electron-phonon coupling by high-magnetic field Raman scattering while electrostatic tuning of the carrier density controls the filling factor. We show qualitative and quantitative agreement between spectra and a linearized model of electron-phonon interactions in magnetic fields. The splitting is caused by dichroism of left- and right-handed circular polarized light due to lifting of the G-band phonon degeneracy, and the piecewise linear slopes are caused by the linear occupancy of sequential Landau levels versus ν.
NASA Astrophysics Data System (ADS)
Kumar, Devendra; Singh, Jagdev; Baleanu, Dumitru
2018-02-01
The mathematical model of breaking of non-linear dispersive water waves with memory effect is very important in mathematical physics. In the present article, we examine a novel fractional extension of the non-linear Fornberg-Whitham equation occurring in wave breaking. We consider the most recent theory of differentiation involving the non-singular kernel based on the extended Mittag-Leffler-type function to modify the Fornberg-Whitham equation. We examine the existence of the solution of the non-linear Fornberg-Whitham equation of fractional order. Further, we show the uniqueness of the solution. We obtain the numerical solution of the new arbitrary order model of the non-linear Fornberg-Whitham equation with the aid of the Laplace decomposition technique. The numerical outcomes are displayed in the form of graphs and tables. The results indicate that the Laplace decomposition algorithm is a very user-friendly and reliable scheme for handling such type of non-linear problems of fractional order.
Hard copies for digital medical images: an overview
NASA Astrophysics Data System (ADS)
Blume, Hartwig R.; Muka, Edward
1995-04-01
This paper is a condensed version of an invited overview on the technology of film hard-copies used in radiology. Because the overview was given to an essentially nonmedical audience, the reliance on film hard-copies in radiology is outlined in greater detail. The overview is concerned with laser image recorders generating monochrome prints on silver-halide films. The basic components of laser image recorders are sketched. The paper concentrates on the physical parameters - characteristic function, dynamic range, digitization resolution, modulation transfer function, and noise power spectrum - which define image quality and information transfer capability of the printed image. A preliminary approach is presented to compare the printed image quality with noise in the acquired image as well as with the noise of state-of- the-art cathode-ray-tube display systems. High-performance laser-image- recorder/silver-halide-film/light-box systems are well capable of reproducing acquired radiologic information. Most recently development was begun toward a display function standard for soft-copy display systems to facilitate similarity of image presentation between different soft-copy displays as well as between soft- and hard-copy displays. The standard display function is based on perceptional linearization. The standard is briefly reviewed to encourage the printer industry to adopt it, too.
Titus, James K; Kay, Matthew K; Glaser, CDR Jacob J
2017-01-01
Snakebite envenomation is an important global health concern. The current standard treatment approach for snakebite envenomation relies on antibody-based antisera, which are expensive, not universally available, and can lead to adverse physiological effects. Phage display techniques offer a powerful tool for the selection of phage-expressed peptides, which can bind with high specificity and affinity towards venom components. In this research, the amino acid sequences of Phospholipase A2 (PLA2) from multiple cottonmouth species were analyzed, and a consensus peptide synthesized. Three phage display libraries were panned against this consensus peptide, crosslinked to capillary tubes, followed by a modified surface panning procedure. This high throughput selection method identified four phage clones with anti-PLA2 activity against Western cottonmouth venom, and the amino acid sequences of the displayed peptides were identified. This is the first report identifying short peptide sequences capable of inhibiting PLA2 activity of Western cottonmouth venom in vitro, using a phage display technique. Additionally, this report utilizes synthetic panning targets, designed using venom proteomic data, to mimic epitope regions. M13 phages displaying circular 7-mer or linear 12-mer peptides with antivenom activity may offer a novel alternative to traditional antibody-based therapy. PMID:29285351
Titus, James K; Kay, Matthew K; Glaser, Cdr Jacob J
2017-01-01
Snakebite envenomation is an important global health concern. The current standard treatment approach for snakebite envenomation relies on antibody-based antisera, which are expensive, not universally available, and can lead to adverse physiological effects. Phage display techniques offer a powerful tool for the selection of phage-expressed peptides, which can bind with high specificity and affinity towards venom components. In this research, the amino acid sequences of Phospholipase A 2 (PLA 2 ) from multiple cottonmouth species were analyzed, and a consensus peptide synthesized. Three phage display libraries were panned against this consensus peptide, crosslinked to capillary tubes, followed by a modified surface panning procedure. This high throughput selection method identified four phage clones with anti-PLA 2 activity against Western cottonmouth venom, and the amino acid sequences of the displayed peptides were identified. This is the first report identifying short peptide sequences capable of inhibiting PLA 2 activity of Western cottonmouth venom in vitro , using a phage display technique. Additionally, this report utilizes synthetic panning targets, designed using venom proteomic data, to mimic epitope regions. M13 phages displaying circular 7-mer or linear 12-mer peptides with antivenom activity may offer a novel alternative to traditional antibody-based therapy.
Bacteriophage T4 capsid packaging and unpackaging of DNA and proteins.
Mullaney, Julienne M; Black, Lindsay W
2014-01-01
Bacteriophage T4 has proven itself readily amenable to phage-based DNA and protein packaging, expression, and display systems due to its physical resiliency and genomic flexibility. As a large dsDNA phage with dispensable internal proteins and dispensable outer capsid proteins it can be adapted to package both DNA and proteins of interest within the capsid and to display peptides and proteins externally on the capsid. A single 170 kb linear DNA, or single or multiple copies of shorter linear DNAs, of any sequence can be packaged by the large terminase subunit in vitro into protein-containing proheads and give full or partially full capsids. The prohead receptacles for DNA packaging can also display peptides or full-length proteins from capsid display proteins HOC and SOC. Our laboratory has also developed a protein expression, packaging, and processing (PEPP) system which we have found to have advantages over mammalian and bacterial cell systems, including high yield, increased stability, and simplified downstream processing. Proteins that we have produced by the phage PEPP platform include human HIV-1 protease, micrococcal endonuclease from Staphylococcus aureus, restriction endonuclease EcoRI, luciferase, human granulocyte colony stimulating factor (GCSF), green fluorescent protein (GFP), and the 99 amino acid C-terminus of amyloid precursor protein (APP). Difficult to produce proteins that are toxic in mammalian protein expression systems are easily produced, packaged, and processed with the PEPP platform. APP is one example of such a highly refractory protein that has been produced successfully. The methods below describe the procedures for in vitro packaging of proheads with DNA and for producing recombinant T4 phage that carry a gene of interest in the phage genome and produce and internally package the corresponding protein of interest.
NASA Astrophysics Data System (ADS)
Podzharenko, Volodymyr A.; Kulakov, Pavlo I.
2001-06-01
The photo-electric angle transmitter of rotation is offered, at which the output voltage is linear function of entering magnitude. In a transmitter the linear phototransducer is used on the basis of pair photo diode -- operating amplifier, which output voltage is linear function of the area of an illuminated photosensitive stratum, and modulator of a light stream of the special shape, which ensures a linear dependence of this area from an angle of rotation. The transmitter has good frequent properties and can be used for dynamic measurements of an angular velocity and angle of rotation, in systems of exact drives and systems of autocontrol.
NASA Astrophysics Data System (ADS)
Gou, Jun; Niu, Qingchen; Liang, Kai; Wang, Jun; Jiang, Yadong
2018-03-01
Antenna-coupled micro-bridge structure is proven to be a good solution to extend infrared micro-bolometer technology for THz application. Spiral-type antennas are proposed in 25 μm × 25 μm micro-bridge structure with a single separate linear antenna, two separate linear antennas, or two connected linear antennas on the bridge legs, in addition to traditional spiral-type antenna on the support layer. The effects of structural parameters of each antenna on THz absorption of micro-bridge structure are discussed for optimized absorption of 2.52 THz wave radiated by far infrared CO2 lasers. The design of spiral-type antenna with two separate linear antennas for wide absorption peak and spiral-type antenna with two connected linear antennas for relatively stable absorption are good candidates for high absorption at low absorption frequency with a rotation angle of 360* n ( n = 1.6). Spiral-type antenna with extended legs also provides a highly integrated micro-bridge structure with fast response and a highly compatible, process-simplified way to realize the structure. This research demonstrates the design of several spiral-type antenna-coupled micro-bridge structures and provides preferred schemes for potential device applications in room temperature sensing and real-time imaging.
Gou, Jun; Niu, Qingchen; Liang, Kai; Wang, Jun; Jiang, Yadong
2018-03-05
Antenna-coupled micro-bridge structure is proven to be a good solution to extend infrared micro-bolometer technology for THz application. Spiral-type antennas are proposed in 25 μm × 25 μm micro-bridge structure with a single separate linear antenna, two separate linear antennas, or two connected linear antennas on the bridge legs, in addition to traditional spiral-type antenna on the support layer. The effects of structural parameters of each antenna on THz absorption of micro-bridge structure are discussed for optimized absorption of 2.52 THz wave radiated by far infrared CO 2 lasers. The design of spiral-type antenna with two separate linear antennas for wide absorption peak and spiral-type antenna with two connected linear antennas for relatively stable absorption are good candidates for high absorption at low absorption frequency with a rotation angle of 360*n (n = 1.6). Spiral-type antenna with extended legs also provides a highly integrated micro-bridge structure with fast response and a highly compatible, process-simplified way to realize the structure. This research demonstrates the design of several spiral-type antenna-coupled micro-bridge structures and provides preferred schemes for potential device applications in room temperature sensing and real-time imaging.
Interactive Multiple-Representation Editing of Physically-based 3D Animation
1994-05-29
view similar to that of FrameMaker [46], but with a stronger model of structured editing, and a language window, which displays a formal description of...used. This is partly a result of the power of a good direct manipulation editor { most users of good editors like FrameMaker don’t seem to miss having a...re nement. In SIG- GRAPH, pages 205{212, August 1988. [46] Frame Technology Inc. Using FrameMaker , 1990. [47] Bjorn N. Freeman-Benson and John Maloney
Simulator study of a pictorial display for general aviation instrument flight
NASA Technical Reports Server (NTRS)
Adams, J. J.
1982-01-01
A simulation study of a computer drawn pictorial display involved a flight task that included an en route segment, terminal area maneuvering, a final approach, a missed approach, and a hold. The pictorial display consists of the drawing of boxes which either move along the desired path or are fixed at designated way points. Two boxes may be shown at all times, one related to the active way point and the other related to the standby way point. Ground tracks and vertical profiles of the flights, time histories of the final approach, and comments were obtained from time pilots. The results demonstrate the accuracy and consistency with which the segments of the flight are executed. The pilots found that the display is easy to learn and to use; that it provides good situation awareness, and that it could improve the safety of flight. The small size of the display, the lack of numerical information on pitch, roll, and heading angles, and the lack of definition of the boundaries of the conventional glide slope and localizer areas were criticized.
Tobacco advertising in retail stores.
Cummings, K M; Sciandra, R; Lawrence, J
1991-01-01
Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were surveyed to determine their store's policy regarding tobacco advertising, receipt of monetary incentives from distributors for displaying tobacco ads, and willingness to display antitobacco ads. Six types of stores were involved in the study: 10 supermarkets, 10 privately owned grocery stores, 9 chain convenience food stores that do not sell gasoline, 11 chain convenience food stores that sell gasoline, 11 chain pharmacies, and 10 private pharmacies. Two-thirds of the stores displayed tobacco posters, and 87 percent had promotional items advertising tobacco products, primarily cigarettes. Larger stores, and those that were privately owned, tended to display more posters and promotional items. Eighty percent of tobacco product displays were for cigarettes, 16 percent for smokeless tobacco products, and 4 percent for cigars and pipe tobacco. Convenience stores selling gasoline had the most separate tobacco product displays. Of tobacco product displays, 24 percent were located adjacent to candy and snack displays. Twenty-nine of the 61 store owners or managers indicated that their store had a policy regulating the display of tobacco ads and tobacco product displays.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1910192
Direct reading inductance meter
NASA Technical Reports Server (NTRS)
Kolby, R. B. (Inventor)
1977-01-01
A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.
Scaling effects in a non-linear electromagnetic energy harvester for wearable sensors
NASA Astrophysics Data System (ADS)
Geisler, M.; Boisseau, S.; Perez, M.; Ait-Ali, I.; Perraud, S.
2016-11-01
In the field of inertial energy harvesters targeting human mechanical energy, the ergonomics of the solutions impose to find the best compromise between dimensions reduction and electrical performance. In this paper, we study the properties of a non-linear electromagnetic generator at different scales, by performing simulations based on an experimentally validated model and real human acceleration recordings. The results display that the output power of the structure is roughly proportional to its scaling factor raised to the power of five, which indicates that this system is more relevant at lengths over a few centimetres.
Principal components colour display of ERTS imagery
NASA Technical Reports Server (NTRS)
Taylor, M. M.
1974-01-01
In the technique presented, colours are not derived from single bands, but rather from independent linear combinations of the bands. Using a simple model of the processing done by the visual system, three informationally independent linear combinations of the four ERTS bands are mapped onto the three visual colour dimensions of brightness, redness-greenness and blueness-yellowness. The technique permits user-specific transformations which enhance particular features, but this is not usually needed, since a single transformation provides a picture which conveys much of the information implicit in the ERTS data. Examples of experimental vector images with matched individual band images are shown.
Matsumoto, Yuji; Takaki, Yasuhiro
2014-06-15
Horizontally scanning holography can enlarge both screen size and viewing zone angle. A microelectromechanical-system spatial light modulator, which can generate only binary images, is used to generate hologram patterns. Thus, techniques to improve gray-scale representation in reconstructed images should be developed. In this study, the error diffusion technique was used for the binarization of holograms. When the Floyd-Steinberg error diffusion coefficients were used, gray-scale representation was improved. However, the linearity in the gray-scale representation was not satisfactory. We proposed the use of a correction table and showed that the linearity was greatly improved.
Symmetric linear systems - An application of algebraic systems theory
NASA Technical Reports Server (NTRS)
Hazewinkel, M.; Martin, C.
1983-01-01
Dynamical systems which contain several identical subsystems occur in a variety of applications ranging from command and control systems and discretization of partial differential equations, to the stability augmentation of pairs of helicopters lifting a large mass. Linear models for such systems display certain obvious symmetries. In this paper, we discuss how these symmetries can be incorporated into a mathematical model that utilizes the modern theory of algebraic systems. Such systems are inherently related to the representation theory of algebras over fields. We will show that any control scheme which respects the dynamical structure either implicitly or explicitly uses the underlying algebra.
Bender, Aaron M; Clark, Mary J; Agius, Michael P; Traynor, John R; Mosberg, Henry I
2014-01-15
In this letter, we describe a series of 4-substituted piperidine and piperazine compounds based on tetrahydroquinoline 1, a compound that shows balanced, low nanomolar binding affinity for the mu opioid receptor (MOR) and the delta opioid receptor (DOR). We have shown that by changing the length and flexibility profile of the side chain in this position, binding affinity is improved at both receptors by a significant degree. Furthermore, several of the compounds described herein display good efficacy at MOR, while simultaneously displaying DOR antagonism. The MOR agonist/DOR antagonist has shown promise in the reduction of negative side effects displayed by selective MOR agonists, namely the development of dependence and tolerance. Copyright © 2013 Elsevier Ltd. All rights reserved.
Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A
2015-05-01
Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
A parallel algorithm for the eigenvalues and eigenvectors for a general complex matrix
NASA Technical Reports Server (NTRS)
Shroff, Gautam
1989-01-01
A new parallel Jacobi-like algorithm is developed for computing the eigenvalues of a general complex matrix. Most parallel methods for this parallel typically display only linear convergence. Sequential norm-reducing algorithms also exit and they display quadratic convergence in most cases. The new algorithm is a parallel form of the norm-reducing algorithm due to Eberlein. It is proven that the asymptotic convergence rate of this algorithm is quadratic. Numerical experiments are presented which demonstrate the quadratic convergence of the algorithm and certain situations where the convergence is slow are also identified. The algorithm promises to be very competitive on a variety of parallel architectures.
Generation of helical Ince-Gaussian beams: beam-shaping with a liquid crystal display
NASA Astrophysics Data System (ADS)
Davis, Jeffrey A.; Bentley, Joel B.; Bandres, Miguel A.; Gutiérrez-Vega, Julio C.
2006-08-01
We review the three types of laser beams - Hermite-Gaussian (HG), Laguerre-Gaussian (LG) and the newly discovered Ince-Gaussian (IG) beams. We discuss the helical forms of the LG and IG beams that consist of linear combinations of the even and odd solutions and form a number of vortices that are useful for optical trapping applications. We discuss how to generate these beams by encoding the desired amplitude and phase onto a single parallel-aligned liquid crystal display (LCD). We introduce a novel interference technique where we generate both the object and reference beams using a single LCD and show the vortex interference patterns.
Graphic Display of Linguistic Information in English as a Foreign Language Reading
ERIC Educational Resources Information Center
Suzuki, Akio; Sato, Takeshi; Awazu, Shunji
2008-01-01
Two studies investigated the advantage and instructional effectiveness of the spatial graphic representation of an English sentence with coordinators over a linear sentential representation in English as a foreign language (EFL) reading settings. Experiment 1, Study 1, examined whether readers studying EFL could better comprehend the sentence--in…
Identifying Predictors of Physics Item Difficulty: A Linear Regression Approach
ERIC Educational Resources Information Center
Mesic, Vanes; Muratovic, Hasnija
2011-01-01
Large-scale assessments of student achievement in physics are often approached with an intention to discriminate students based on the attained level of their physics competencies. Therefore, for purposes of test design, it is important that items display an acceptable discriminatory behavior. To that end, it is recommended to avoid extraordinary…
First report of xanthomonas vasicola causing bacterial leaf streak on corn in the United States
USDA-ARS?s Scientific Manuscript database
In 2014 and 2015, Zea mays samples (field, seed, and popcorn) were submitted to the Plant and Pest Diagnostic Clinic at the University of Nebraska – Lincoln displaying long, dark, yellow to brown, water-soaked, linear lesions confined to the interveinal spaces of the leaves. Initial symptoms appeare...
ERIC Educational Resources Information Center
Ng, Kwong Bor; Rieh, Soo Young; Kantor, Paul
2000-01-01
Discussion of natural language processing focuses on experiments using linear discriminant analysis to distinguish "Wall Street Journal" texts from "Federal Register" tests using information about the frequency of occurrence of word boundaries, sentence boundaries, and punctuation marks. Displays and interprets results in terms…
A Psychophysical Test of the Visual Pathway of Children with Autism
ERIC Educational Resources Information Center
Sanchez-Marin, Francisco J.; Padilla-Medina, Jose A.
2008-01-01
Signal detection psychophysical experiments were conducted to investigate the visual path of children with autism. Computer generated images with Gaussian noise were used. Simple signals, still and in motion were embedded in the background noise. The computer monitor was linearized to properly display the contrast changes. To our knowledge, this…
Basilar skull fracture; Depressed skull fracture; Linear skull fracture ... Skull fractures may occur with head injuries . The skull provides good protection for the brain. However, a severe impact ...
Zhang, Yawen; Li, Yunqiu; Wu, Wenjian; Jiang, Yuren; Hu, Biru
2014-10-15
A glucose biosensor was developed via direct immobilization of glucose oxidase (GOD) by self-assembled cysteamine monolayer on Au electrode surface followed by coating chitosan on the surface of electrode. In this work, chitosan film was coated on the surface of GOD as a protection film to ensure the stability and biocompatibility of the constructed glucose biosensor. The different application ranges of sensors were fabricated by immobilizing varied layers of GOD. The modified surface film was characterized by a scanning electron microscope (SEM) and the fabrication process of the biosensor was confirmed through electrochemical impedance spectroscopy (EIS) of ferrocyanide. The performance of cyclic voltammetry (CV) in the absence and presence of 25 mM glucose and ferrocenemethanol showed a diffusion-controlled electrode process and reflected the different maximum currents between the different GOD layers. With the developed glucose biosensor, the detection limits of the two linear responses are 49.96 μM and 316.8 μM with the sensitivities of 8.91 μA mM(-1)cm(-2) and 2.93 μA mM(-1)cm(-2), respectively. In addition, good stability (up to 30 days) of the developed biosensor was observed. The advantages of this new method for sensors construction was convenient and different width ranges of detection can be obtained by modified varied layers of GOD. The sensor with two layers of enzyme displayed two current linear responses of glucose. The present work provided a simplicity and novelty method for producing biosensors, which may help design enzyme reactors and biosensors in the future. Copyright © 2014 Elsevier B.V. All rights reserved.
Kunkel, Maria E; Herkommer, Andrea; Reinehr, Michael; Böckers, Tobias M; Wilke, Hans-Joachim
2011-01-01
The main aim of this study was to provide anatomical data on the heights of the human intervertebral discs for all levels of the thoracic spine by direct and radiographic measurements. Additionally, the heights of the neighboring vertebral bodies were measured, and the prediction of the disc heights based only on the size of the vertebral bodies was investigated. The anterior (ADH), middle (MDH) and posterior heights (PDH) of the discs were measured directly and on radiographs of 72 spine segments from 30 donors (age 57.43 ± 11.27 years). The radiographic measurement error and the reliability of the measurements were calculated. Linear and non-linear regression analyses were employed for investigation of statistical correlations between the heights of the thoracic disc and vertebrae. Radiographic measurements displayed lower repeatability and were shorter than the anatomical ones (approximately 9% for ADH and 37% for PDH). The thickness of the discs varied from 4.5 to 7.2 mm, with the MDH approximately 22.7% greater. The disc heights showed good correlations with the vertebral body heights (R2, 0.659–0.835, P-values < 0.005; anova), allowing the generation of 10 prediction equations. New data on thoracic disc morphometry were provided in this study. The generated set of regression equations could be used to predict thoracic disc heights from radiographic measurement of the vertebral body height posterior. For the creation of parameterized models of the human thoracic discs, the use of the prediction equations could eliminate the need for direct measurement on intervertebral discs. Moreover, the error produced by radiographic measurements could be reduced at least for the PDH. PMID:21615399
Sun, Junyong; Mei, Han; Gao, Feng
2017-05-15
The rational surface functionalization of semiconducting polymer dots (Pdots) has attracted much attention to extend their applications in fabricating chemo/biosensing platform. In this study, a novel ratiometric fluorescent sensing platform using functionalized Pdots as probes for fluorescence signal transmission has been designed for sensing Cu(Ⅱ) and activity of alkaline phosphatase (ALP) with high selectivity and enhanced sensitivity. The highly fluorescent Pdots were firstly prepared with Poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(1,4-benzo-{2,1',3}-thiadiazole)] (PFBT) via nanoprecipitation method, and then assembled with non-fluorescent rhodamine B hydrazide (RB-hy), which shows special binding activity to Cu(Ⅱ), through adsorption process to obtain functionalized nanohybrids, Pdots@RB-hy. As thus, a FRET donors/acceptors pair, in which PFBT Pdots act as energy donors while RB-hy-Cu(II) complexes act as energy acceptors were constructed. On the basis of the varies in fluorescence intensities of donors/acceptors in the presence of different amounts of Cu(II), a ratiometric method for sensing Cu(II) has been proposed. The proposed ratiometric Cu(II) sensor shows a good linear detection range from 0.05 to 5μM with a detection limit of 15nM. Furthermore, using the Pdots@RB-hy-Cu(II) system as signal transducer, a ratiometric sensing for alkaline phosphatase (ALP) activity has also been established with pyrophosphate (PPi) as substrates. The constructed ratiometric sensor of ALP activity displays a linear detection range from 0.005 to 15UL -1 with a detection limit of 0.0018UL -1 . The sensor was further successfully used for ALP activity detection in human serum with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Liu; Zhang, Jie; Zhao, Faqiong; Zeng, Baizhao
2016-11-04
In this work, a novel poly(3,4-ethylenedioxythiophene)@Au nanoparticles (PEDOT@AuNPs) hybrid coating was prepared and characterized. Firstly, the monomer 3,4-ethylenedioxythiophene was self-assembled on AuNPs, and then electropolymerization was performed on a stainless steel wire by cyclic voltammetry. The obtained PEDOT@AuNPs coating was rough and showed cauliflower-like micro-structure with thickness of ∼40μm. It displayed high thermal stability (up to 330°C) and mechanical stability and could be used for at least 160 times of solid phase microextraction (SPME) without decrease of extraction performance. The coating exhibited high extraction capacity for some environmental pollutants (e.g. naphthalene, 2-methylnaphthalene, acenaphthene, fluorene and phenathrene) due to the hydrophobic interaction between the analytes and PEDOT and the additional physicochemical affinity between polycyclic aromatic hydrocarbons and AuNPs. Through coupling with GC detection, good linearity (correlation coefficients higher than 0.9894), wide linear range (0.01-100μgL -1 ), low limits of detection (2.5-25ngL -1 ) were achieved for these analytes. The reproducibility (defined as RSD) was 1.1-4.0% and 5.8-9.9% for single fiber (n=5) and fiber-to-fiber (n=5), respectively. The SPME-GC method was successfully applied for the determination of three real samples, and the recoveries for standards added were 89.9-106% for lake water, 95.7-112% for rain water and 93.2-109% for soil saturated water, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Hou, Tingjun; Xu, Xiaojie
2002-12-01
In this study, the relationships between the brain-blood concentration ratio of 96 structurally diverse compounds with a large number of structurally derived descriptors were investigated. The linear models were based on molecular descriptors that can be calculated for any compound simply from a knowledge of its molecular structure. The linear correlation coefficients of the models were optimized by genetic algorithms (GAs), and the descriptors used in the linear models were automatically selected from 27 structurally derived descriptors. The GA optimizations resulted in a group of linear models with three or four molecular descriptors with good statistical significance. The change of descriptor use as the evolution proceeds demonstrates that the octane/water partition coefficient and the partial negative solvent-accessible surface area multiplied by the negative charge are crucial to brain-blood barrier permeability. Moreover, we found that the predictions using multiple QSPR models from GA optimization gave quite good results in spite of the diversity of structures, which was better than the predictions using the best single model. The predictions for the two external sets with 37 diverse compounds using multiple QSPR models indicate that the best linear models with four descriptors are sufficiently effective for predictive use. Considering the ease of computation of the descriptors, the linear models may be used as general utilities to screen the blood-brain barrier partitioning of drugs in a high-throughput fashion.
NASA Technical Reports Server (NTRS)
Grody, N. C.
1973-01-01
Linear and nonlinear responses of a magnetoplasma resulting from inhomogeneity in the background plasma density are studied. The plasma response to an impulse electric field was measured and the results are compared with the theory of an inhomogeneous cold plasma. Impulse responses were recorded for the different plasma densities, static magnetic fields, and neutral pressures and generally appeared as modulated, damped oscillations. The frequency spectra of the waveforms consisted of two separated resonance peaks. For weak excitation, the results correlate with the linear theory of a cold, inhomogeneous, cylindrical magnetoplasma. The damping mechanism is identified with that of phase mixing due to inhomogeneity in plasma density. With increasing excitation voltage, the nonlinear impulse responses display stronger damping and a small increase in the frequency of oscillation.
Circularized Chromosome with a Large Palindromic Structure in Streptomyces griseus Mutants
Uchida, Tetsuya; Ishihara, Naoto; Zenitani, Hiroyuki; Hiratsu, Keiichiro; Kinashi, Haruyasu
2004-01-01
Streptomyces linear chromosomes display various types of rearrangements after telomere deletion, including circularization, arm replacement, and amplification. We analyzed the new chromosomal deletion mutants Streptomyces griseus 301-22-L and 301-22-M. In these mutants, chromosomal arm replacement resulted in long terminal inverted repeats (TIRs) at both ends; different sizes were deleted again and recombined inside the TIRs, resulting in a circular chromosome with an extremely large palindrome. Short palindromic sequences were found in parent strain 2247, and these sequences might have played a role in the formation of this unique structure. Dynamic structural changes of Streptomyces linear chromosomes shown by this and previous studies revealed extraordinary strategies of members of this genus to keep a functional chromosome, even if it is linear or circular. PMID:15150216
NASA Technical Reports Server (NTRS)
Cole, M. M. (Principal Investigator); Owen-Jones, S.
1976-01-01
The author has identified the following significant results. Distinctive spectral signatures were found associated with areas of near surface bedrock with covered ground east of Dugald River and along the Thorntonia River valley west of Lady Annie. Linears identified in the Dugald River area on LANDSAT 2 imagery taken in March and July 1975 over the Cloncurry-Dobbyn area, displayed preferred orientation. A linear group with NE-SW orientation was identified in the Lady Annie area. In this area, the copper mineralization in the Mt. Kelly area occurs along a well marked linear with NNW/SSE direction apparent on images for March, September, and November 1975. Geobotanical anomalies provided surface expression of the copper deposits in Mt. Kelley.
Video-laryngoscopy introduction in a Sub-Saharan national teaching hospital: luxury or necessity?
Alain, Traoré Ibrahim; Drissa, Barro Sié; Flavien, Kaboré; Serge, Ilboudo; Idriss, Traoré
2015-01-01
Tracheal intubation using Macintosh blade is the technique of choice for the liberation of airways. It can turn out to be difficult, causing severe complications which can entail the prognosis for survival or the adjournment of the surgical operation. The video-laryngoscope allows a better display of the larynx and a good exposure of the glottis and then making tracheal intubation simpler compared with a conventional laryngoscope. It is little spread in sub-Saharan Africa and more particularly in Burkina Faso because of its high cost. We report our first experiences of use of the video-laryngoscope through two cases of difficult tracheal intubation which had required the adjournment of the interventions. It results that the video-laryngoscope makes tracheal intubation easier even in it's the first use because of the good glottal display which it gives and because its allows apprenticeship easy. Therefore, it is not a luxury to have it in our therapeutic arsenal. PMID:27047621
Preparation and characterization of monoclonal antibody against digoxin.
Kashanian, S; Rasaee, M J; Paknejad, M; Omidfar, K; Pour-Amir, M; Rajabi, Bazl M
2002-10-01
Mouse-mouse hybridoma cell lines producing stable, highly specific and with good affinity monoclonal antibody (MAb) against the cardiac glycoside digoxin were established. Balb/c mice were immunized via injection of digoxin-3'-bovine serum albumin (BSA). The spleens of which were fused with myeloma cells of SP2/0 origin. Three clones designated as BBA, MBE, and BMG producing good antibodies displayed different patterns of fine specificity for digoxin and low cross-reaction with several digoxin analogues as elucidated by inhibition enzyme-linked immunosorbant assay (ELISA). All three MAbs were of the same class and subclass (IgG(1)). Affinity purification was performed for the selected clone BBA displaying the highest affinity and nearly no cross-reactivity with any of the structurally related molecules. Ultrafiltered concentrated hybrid cell supernatant was also purified by polyethylene glycol (PEG) 6000 precipitation for large-scale preparation and coated onto the wells of microtiter plates. The standard curve was constructed with a sensitivity of 10 pg/well covering up to 10 ng/well.
Drinkel, Emma E; Campedelli, Roberta R; Manfredi, Alex M; Fiedler, Haidi D; Nome, Faruk
2014-03-21
Palladium nanoparticles (NPs) stabilized by a zwitterionic surfactant are revealed here to be good catalysts for the reductive amination of benzaldehydes using formate salts as hydrogen donors in aqueous isopropanol. In terms of environmental impact and economy, metallic NPs offer several advantages over homogeneous and traditional heterogeneous catalysts. NPs usually display greater activity due to the increased metal surface area and sometimes exhibit enhanced selectivity. Thus, it is possible to use very low loadings of expensive metal. The methodology eliminates the use of a hydrogen gas atmosphere or toxic or expensive reagents. A range of aromatic aldehydes were converted to benzylamines when reacted with primary and secondary amines in the presence of the Pd NPs, which also displayed good activity when supported on alumina. In every case, the Pd NPs could be easily recovered and reused up to three more times, and at the end of the process, the product was metal-free.
Manzanilla, Linda R.
2015-01-01
In this paper, I address the case of a corporate society in Central Mexico. After volcanic eruptions triggered population displacements in the southern Basin of Mexico during the first and fourth centuries A.D., Teotihuacan became a multiethnic settlement. Groups from different backgrounds settled primarily on the periphery of the metropolis; nevertheless, around the core, intermediate elites actively fostered the movement of sumptuary goods and the arrival of workers from diverse homelands for a range of specialized tasks. Some of these skilled craftsmen acquired status and perhaps economic power as a result of the dynamic competition among neighborhoods to display the most lavish sumptuary goods, as well as to manufacture specific symbols of identity that distinguished one neighborhood from another, such as elaborate garments and headdresses. Cotton attire worn by the Teotihuacan elite may have been one of the goods that granted economic importance to neighborhood centers such as Teopancazco, a compound that displayed strong ties to the Gulf Coast where cotton cloth was made. The ruling elite controlled raw materials that came from afar whereas the intermediate elite may have been more active in providing other sumptuary goods: pigments, cosmetics, slate, greenstone, travertine, and foreign pottery. The contrast between the corporate organization at the base and top of Teotihuacan society and the exclusionary organization of the neighborhoods headed by the highly competitive intermediate elite introduced tensions that set the stage for Teotihuacan’s collapse. PMID:25775567
Manzanilla, Linda R
2015-07-28
In this paper, I address the case of a corporate society in Central Mexico. After volcanic eruptions triggered population displacements in the southern Basin of Mexico during the first and fourth centuries A.D., Teotihuacan became a multiethnic settlement. Groups from different backgrounds settled primarily on the periphery of the metropolis; nevertheless, around the core, intermediate elites actively fostered the movement of sumptuary goods and the arrival of workers from diverse homelands for a range of specialized tasks. Some of these skilled craftsmen acquired status and perhaps economic power as a result of the dynamic competition among neighborhoods to display the most lavish sumptuary goods, as well as to manufacture specific symbols of identity that distinguished one neighborhood from another, such as elaborate garments and headdresses. Cotton attire worn by the Teotihuacan elite may have been one of the goods that granted economic importance to neighborhood centers such as Teopancazco, a compound that displayed strong ties to the Gulf Coast where cotton cloth was made. The ruling elite controlled raw materials that came from afar whereas the intermediate elite may have been more active in providing other sumptuary goods: pigments, cosmetics, slate, greenstone, travertine, and foreign pottery. The contrast between the corporate organization at the base and top of Teotihuacan society and the exclusionary organization of the neighborhoods headed by the highly competitive intermediate elite introduced tensions that set the stage for Teotihuacan's collapse.
21-nm-range wavelength-tunable L-band Er-doped fiber linear-cavity laser
NASA Astrophysics Data System (ADS)
Yang, Shiquan; Zhao, Chunliu; Li, Zhaohui; Ding, Lei; Yuan, Shuzhong; Dong, Xiaoyi
2001-10-01
A novel method, which utilizes amplified spontaneous emission (ASE) as a secondary pump source, is presented for implanting a linear cavity erbium-doped fiber laser operating in L-Band. The output wavelength tuned from 1566 nm to 1587 nm, about 21 nm tuning range, was obtained in the experiment and the stability of the laser is very good.
Differences in Expressivity Based on Attractiveness: Target or Perceiver Effects?
Rennels, Jennifer L; Kayl, Andrea J
2015-09-01
A significant association exists between adults' expressivity and facial attractiveness, but it is unclear whether the association is linear or significant only at the extremes of attractiveness. It is also unclear whether attractive persons actually display more positive expressivity than unattractive persons (target effects) or whether high and low attractiveness influences expressivity valence judgments (perceiver effects). Experiment 1 demonstrated adult ratings of attractiveness were predictive of expressivity valence only for high and low attractive females and medium attractive males. Experiment 2 showed that low attractive females actually display more negative expressivity than medium and high attractive females, but there were no target effects for males. Also, attractiveness influenced expressivity valence judgments (perceiver effects) for both females and males. Our findings demonstrate that low attractive females are at a particular disadvantage during social interactions due to their low attractiveness, actual displays of negative expressivity, and perceptions of their negative expressivity.
NASA Astrophysics Data System (ADS)
Chen, Chun-Jen; Wu, Wen-Hong; Huang, Kuo-Cheng
2009-08-01
A multi-function lens test instrument is report in this paper. This system can evaluate the image resolution, image quality, depth of field, image distortion and light intensity distribution of the tested lens by changing the tested patterns. This system consists of a tested lens, a CCD camera, a linear motorized stage, a system fixture, an observer LCD monitor, and a notebook for pattern providing. The LCD monitor displays a serious of specified tested patterns sent by the notebook. Then each displayed pattern goes through the tested lens and images in the CCD camera sensor. Consequently, the system can evaluate the performance of the tested lens by analyzing the image of CCD camera with special designed software. The major advantage of this system is that it can complete whole test quickly without interruption due to part replacement, because the tested patterns are statically displayed on monitor and controlled by the notebook.
Differences in Expressivity Based on Attractiveness: Target or Perceiver Effects?
Rennels, Jennifer L.; Kayl, Andrea J.
2015-01-01
A significant association exists between adults’ expressivity and facial attractiveness, but it is unclear whether the association is linear or significant only at the extremes of attractiveness. It is also unclear whether attractive persons actually display more positive expressivity than unattractive persons (target effects) or whether high and low attractiveness influences expressivity valence judgments (perceiver effects). Experiment 1 demonstrated adult ratings of attractiveness were predictive of expressivity valence only for high and low attractive females and medium attractive males. Experiment 2 showed that low attractive females actually display more negative expressivity than medium and high attractive females, but there were no target effects for males. Also, attractiveness influenced expressivity valence judgments (perceiver effects) for both females and males. Our findings demonstrate that low attractive females are at a particular disadvantage during social interactions due to their low attractiveness, actual displays of negative expressivity, and perceptions of their negative expressivity. PMID:26366010
Protograph based LDPC codes with minimum distance linearly growing with block size
NASA Technical Reports Server (NTRS)
Divsalar, Dariush; Jones, Christopher; Dolinar, Sam; Thorpe, Jeremy
2005-01-01
We propose several LDPC code constructions that simultaneously achieve good threshold and error floor performance. Minimum distance is shown to grow linearly with block size (similar to regular codes of variable degree at least 3) by considering ensemble average weight enumerators. Our constructions are based on projected graph, or protograph, structures that support high-speed decoder implementations. As with irregular ensembles, our constructions are sensitive to the proportion of degree-2 variable nodes. A code with too few such nodes tends to have an iterative decoding threshold that is far from the capacity threshold. A code with too many such nodes tends to not exhibit a minimum distance that grows linearly in block length. In this paper we also show that precoding can be used to lower the threshold of regular LDPC codes. The decoding thresholds of the proposed codes, which have linearly increasing minimum distance in block size, outperform that of regular LDPC codes. Furthermore, a family of low to high rate codes, with thresholds that adhere closely to their respective channel capacity thresholds, is presented. Simulation results for a few example codes show that the proposed codes have low error floors as well as good threshold SNFt performance.
Boundary-Layer Linear Stability Theory
1984-06-01
give aa aapllfieatloa rate that Is 151 too high. This ia an iaproveaeat over the 2D results, but »till net as good as the result obtsleed whoa only th...useful to say about the origin of turbulence, whi ch is inherently nonlinear. A good idea of the low repute of the theory can be gained by reading the...engineering studies of laminar flow control [see, e.g., Hefner and Bushnell ( 1979) ]. A good introduction to the complexities of transition and the
Nonlinear mapping of the luminance in dual-layer high dynamic range displays
NASA Astrophysics Data System (ADS)
Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi
2009-02-01
It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.
Optimal non-linear health insurance.
Blomqvist, A
1997-06-01
Most theoretical and empirical work on efficient health insurance has been based on models with linear insurance schedules (a constant co-insurance parameter). In this paper, dynamic optimization techniques are used to analyse the properties of optimal non-linear insurance schedules in a model similar to one originally considered by Spence and Zeckhauser (American Economic Review, 1971, 61, 380-387) and reminiscent of those that have been used in the literature on optimal income taxation. The results of a preliminary numerical example suggest that the welfare losses from the implicit subsidy to employer-financed health insurance under US tax law may be a good deal smaller than previously estimated using linear models.
NASA Astrophysics Data System (ADS)
Claussen, U.
1984-01-01
The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.
Van Rooyen, Lauren Anne; Allen, Paul; Gallagher, Eimear I; O'Connor, David I
2018-05-24
The effect of CO pretreatments applied to beef striploin steaks (Longissimus thoracis et lumborum, LTL) prior to vacuum packaging and display temperature on colour stability, shelf life and tenderness was determined. Steaks were exposed to 5% CO, 60% CO 2 and 35% N 2 for 3 (CO3), 5 (CO5) or 7 (CO7) h, followed by 28 days display at 2 °C (good industry practice) or 6 °C (mild abuse). CO5 was the optimum exposure time as it induced the desirable colour while not retaining the bright colour, irrespective of display temperature. K/S ratios confirmed that CO pretreatment did not mask spoilage and could be more sensitive than colour parameters at monitoring discoloration as colour was not retained. Exposure to CO did not have any negative effect on meat quality attributes, while mild temperature abuse (6 °C) increased purge loss and decreased pH. Copyright © 2018 Elsevier Ltd. All rights reserved.
Electrical Properties of Reactive Liquid Crystal Semiconductors
NASA Astrophysics Data System (ADS)
McCulloch, Iain; Coelle, Michael; Genevicius, Kristijonas; Hamilton, Rick; Heckmeier, Michael; Heeney, Martin; Kreouzis, Theo; Shkunov, Maxim; Zhang, Weimin
2008-01-01
Fabrication of display products by low cost printing technologies such as ink jet, gravure offset lithography and flexography requires solution processable semiconductors for the backplane electronics. The products will typically be of lower performance than polysilicon transistors, but comparable to amorphous silicon. A range of prototypes are under development, including rollable electrophoretic displays, active matrix liquid crystal displays (AMLCD's), and flexible organic light-emitting diode (OLED) displays. Organic semiconductors that offer both electrical performance and stability with respect to storage and operation under ambient conditions are required. This work describes the initial evaluation of reactive mesogen semiconductors, which can polymerise within mesophase temperatures, “freezing in” the order in crosslinked domains. These crosslinked domains offer mechanical stability and are inert to solvent exposure in further processing steps. Reactive mesogens containing conjugated aromatic cores, designed to facilitate charge transport and provide good oxidative stability, were prepared and their liquid crystalline properties evaluated. Both time-of-flight and field effect transistor devices were prepared and their electrical characterisation reported.
Apparatus for monitoring crystal growth
Sachs, Emanual M.
1981-01-01
A system and method are disclosed for monitoring the growth of a crystalline body from a liquid meniscus in a furnace. The system provides an improved human/machine interface so as to reduce operator stress, strain and fatigue while improving the conditions for observation and control of the growing process. The system comprises suitable optics for forming an image of the meniscus and body wherein the image is anamorphic so that the entire meniscus can be viewed with good resolution in both the width and height dimensions. The system also comprises a video display for displaying the anamorphic image. The video display includes means for enhancing the contrast between any two contrasting points in the image. The video display also comprises a signal averager for averaging the intensity of at least one preselected portions of the image. The value of the average intensity, can in turn be utilized to control the growth of the body. The system and method are also capable of observing and monitoring multiple processes.
Method of monitoring crystal growth
Sachs, Emanual M.
1982-01-01
A system and method are disclosed for monitoring the growth of a crystalline body from a liquid meniscus in a furnace. The system provides an improved human/machine interface so as to reduce operator stress, strain and fatigue while improving the conditions for observation and control of the growing process. The system comprises suitable optics for forming an image of the meniscus and body wherein the image is anamorphic so that the entire meniscus can be viewed with good resolution in both the width and height dimensions. The system also comprises a video display for displaying the anamorphic image. The video display includes means for enhancing the contrast between any two contrasting points in the image. The video display also comprises a signal averager for averaging the intensity of at least one preselected portions of the image. The value of the average intensity, can in turn be utilized to control the growth of the body. The system and method are also capable of observing and monitoring multiple processes.
Pressure wave propagation studies for oscillating cascades
NASA Technical Reports Server (NTRS)
Huff, Dennis L.
1992-01-01
The unsteady flow field around an oscillating cascade of flat plates is studied using a time marching Euler code. Exact solutions based on linear theory serve as model problems to study pressure wave propagation in the numerical solution. The importance of using proper unsteady boundary conditions, grid resolution, and time step is demonstrated. Results show that an approximate non-reflecting boundary condition based on linear theory does a good job of minimizing reflections from the inflow and outflow boundaries and allows the placement of the boundaries to be closer than cases using reflective boundary conditions. Stretching the boundary to dampen the unsteady waves is another way to minimize reflections. Grid clustering near the plates does a better job of capturing the unsteady flow field than cases using uniform grids as long as the CFL number is less than one for a sufficient portion of the grid. Results for various stagger angles and oscillation frequencies show good agreement with linear theory as long as the grid is properly resolved.
Sedimentation of knotted polymers
NASA Astrophysics Data System (ADS)
Piili, J.; Marenduzzo, D.; Kaski, K.; Linna, R. P.
2013-01-01
We investigate the sedimentation of knotted polymers by means of stochastic rotation dynamics, a molecular dynamics algorithm that takes hydrodynamics fully into account. We show that the sedimentation coefficient s, related to the terminal velocity of the knotted polymers, increases linearly with the average crossing number nc of the corresponding ideal knot. This provides direct computational confirmation of this relation, postulated on the basis of sedimentation experiments by Rybenkov [J. Mol. Biol.10.1006/jmbi.1996.0876 267, 299 (1997)]. Such a relation was previously shown to hold with simulations for knot electrophoresis. We also show that there is an accurate linear dependence of s on the inverse of the radius of gyration Rg-1, more specifically with the inverse of the Rg component that is perpendicular to the direction along which the polymer sediments. When the polymer sediments in a slab, the walls affect the results appreciably. However, Rg-1 remains to a good precision linearly dependent on nc. Therefore, Rg-1 is a good measure of a knot's complexity.
NASA Astrophysics Data System (ADS)
Marques, Carlos A. F.; Peng, Gang-Ding; Webb, David J.
2015-05-01
Liquid-level sensing technologies have attracted great prominence, because such measurements are essential to industrial applications, such as fuel storage, flood warning and in the biochemical industry. Traditional liquid level sensors are based on electromechanical techniques; however they suffer from intrinsic safety concerns in explosive environments. In recent years, given that optical fiber sensors have lots of well-established advantages such as high accuracy, costeffectiveness, compact size, and ease of multiplexing, several optical fiber liquid level sensors have been investigated which are based on different operating principles such as side-polishing the cladding and a portion of core, using a spiral side-emitting optical fiber or using silica fiber gratings. The present work proposes a novel and highly sensitive liquid level sensor making use of polymer optical fiber Bragg gratings (POFBGs). The key elements of the system are a set of POFBGs embedded in silicone rubber diaphragms. This is a new development building on the idea of determining liquid level by measuring the pressure at the bottom of a liquid container, however it has a number of critical advantages. The system features several FBG-based pressure sensors as described above placed at different depths. Any sensor above the surface of the liquid will read the same ambient pressure. Sensors below the surface of the liquid will read pressures that increase linearly with depth. The position of the liquid surface can therefore be approximately identified as lying between the first sensor to read an above-ambient pressure and the next higher sensor. This level of precision would not in general be sufficient for most liquid level monitoring applications; however a much more precise determination of liquid level can be made by linear regression to the pressure readings from the sub-surface sensors. There are numerous advantages to this multi-sensor approach. First, the use of linear regression using multiple sensors is inherently more accurate than using a single pressure reading to estimate depth. Second, common mode temperature induced wavelength shifts in the individual sensors are automatically compensated. Thirdly, temperature induced changes in the sensor pressure sensitivity are also compensated. Fourthly, the approach provides the possibility to detect and compensate for malfunctioning sensors. Finally, the system is immune to changes in the density of the monitored fluid and even to changes in the effective force of gravity, as might be obtained in an aerospace application. The performance of an individual sensor was characterized and displays a sensitivity (54 pm/cm), enhanced by more than a factor of 2 when compared to a sensor head configuration based on a silica FBG published in the literature, resulting from the much lower elastic modulus of POF. Furthermore, the temperature/humidity behavior and measurement resolution were also studied in detail. The proposed configuration also displays a highly linear response, high resolution and good repeatability. The results suggest the new configuration can be a useful tool in many different applications, such as aircraft fuel monitoring, and biochemical and environmental sensing, where accuracy and stability are fundamental.
Zhang, Xuqing; Cai, Chaozhong; Sui, Zhihua; Macielag, Mark; Wang, Yuanping; Yan, Wen; Suckow, Arthur; Hua, Hong; Bell, Austin; Haug, Peter; Clapper, Wilma; Jenkinson, Celia; Gunnet, Joseph; Leonard, James; Murray, William V
2017-09-14
We have discovered a novel series of isothiazole-based phenylpropanoic acids as GPR120 agonists. Extensive structure-activity relationship studies led to the discovery of a potent GPR120 agonist 4x , which displayed good EC 50 values in both calcium and β-arrestin assays. It also presented good pharmaceutical properties and a favorable PK profile. Moreover, it demonstrated in vivo antidiabetic activity in C57BL/6 DIO mice. Studies in WT and knockout DIO mice showed that it improved glucose handling during an OGTT via GPR120. Overall, 4x possessed promising antidiabetic effect and good safety profile to be a development candidate.
AgNW/Chinese Xuan paper film heaters for electro-thermochromic paper display
NASA Astrophysics Data System (ADS)
Wang, Guoliang; Xu, Wei; Xu, Feng; Shen, Wenfeng; Song, Weijie
2017-11-01
Electro-thermochromic paper display is the convenient and low-cost device for information presentation. As an integral part of this device, film heaters (FHs) with conductive layer have attracted much attention. In this paper, the AgNW based film heaters on Chinese Xuan paper (CXP) substrates were fabricated by a drop-coating method. The fabricated AgNW/CXP film heaters exhibited high heating temperature (78.1 °C) at low input voltage (3 V) and short response time less than 15 s. We theoretically analyzed the principles of heating and put forward the non-linear relationship between the input power and steady-state temperature, which is agreeing with our experimental data. The film heaters showed excellent mechanical properties with the change of the resistance as low as 2.7% after 2000 times outer bending tests. Finally, the electro-thermochromic paper display was fabricated using the AgNW/CXP film heaters, with the thermochromic inks on the other side of the paper substrate. Such results showed a useful approach for manufacturing of colorful display and color-changing painting.
An information capacity limitation of visual short-term memory.
Sewell, David K; Lilburn, Simon D; Smith, Philip L
2014-12-01
Research suggests that visual short-term memory (VSTM) has both an item capacity, of around 4 items, and an information capacity. We characterize the information capacity limits of VSTM using a task in which observers discriminated the orientation of a single probed item in displays consisting of 1, 2, 3, or 4 orthogonally oriented Gabor patch stimuli that were presented in noise for 50 ms, 100 ms, 150 ms, or 200 ms. The observed capacity limitations are well described by a sample-size model, which predicts invariance of ∑(i)(d'(i))² for displays of different sizes and linearity of (d'(i))² for displays of different durations. Performance was the same for simultaneous and sequentially presented displays, which implicates VSTM as the locus of the observed invariance and rules out explanations that ascribe it to divided attention or stimulus encoding. The invariance of ∑(i)(d'(i))² is predicted by the competitive interaction theory of Smith and Sewell (2013), which attributes it to the normalization of VSTM traces strengths arising from competition among stimuli entering VSTM. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Viewing zone duplication of multi-projection 3D display system using uniaxial crystal.
Lee, Chang-Kun; Park, Soon-Gi; Moon, Seokil; Lee, Byoungho
2016-04-18
We propose a novel multiplexing technique for increasing the viewing zone of a multi-view based multi-projection 3D display system by employing double refraction in uniaxial crystal. When linearly polarized images from projector pass through the uniaxial crystal, two possible optical paths exist according to the polarization states of image. Therefore, the optical paths of the image could be changed, and the viewing zone is shifted in a lateral direction. The polarization modulation of the image from a single projection unit enables us to generate two viewing zones at different positions. For realizing full-color images at each viewing zone, a polarization-based temporal multiplexing technique is adopted with a conventional polarization switching device of liquid crystal (LC) display. Through experiments, a prototype of a ten-view multi-projection 3D display system presenting full-colored view images is implemented by combining five laser scanning projectors, an optically clear calcite (CaCO3) crystal, and an LC polarization rotator. For each time sequence of temporal multiplexing, the luminance distribution of the proposed system is measured and analyzed.
Hemispheric differences in visual search of simple line arrays.
Polich, J; DeFrancesco, D P; Garon, J F; Cohen, W
1990-01-01
The effects of perceptual organization on hemispheric visual-information processing were assessed with stimulus arrays composed of short lines arranged in columns. A visual-search task was employed in which subjects judged whether all the lines were vertical (same) or whether a single horizontal line was present (different). Stimulus-display organization was manipulated in two experiments by variation of line density, linear organization, and array size. In general, left-visual-field/right-hemisphere presentations demonstrated more rapid and accurate responses when the display was perceived as a whole. Right-visual-field/left-hemisphere superiorities were observed when the display organization coerced assessment of individual array elements because the physical qualities of the stimulus did not effect a gestalt whole. Response times increased somewhat with increases in array size, although these effects interacted with other stimulus variables. Error rates tended to follow the reaction-time patterns. The results suggest that laterality differences in visual search are governed by stimulus properties which contribute to, or inhibit, the perception of a display as a gestalt. The implications of these findings for theoretical interpretations of hemispheric specialization are discussed.
NASA Astrophysics Data System (ADS)
Guex, Guillaume
2016-05-01
In recent articles about graphs, different models proposed a formalism to find a type of path between two nodes, the source and the target, at crossroads between the shortest-path and the random-walk path. These models include a freely adjustable parameter, allowing to tune the behavior of the path toward randomized movements or direct routes. This article presents a natural generalization of these models, namely a model with multiple sources and targets. In this context, source nodes can be viewed as locations with a supply of a certain good (e.g. people, money, information) and target nodes as locations with a demand of the same good. An algorithm is constructed to display the flow of goods in the network between sources and targets. With again a freely adjustable parameter, this flow can be tuned to follow routes of minimum cost, thus displaying the flow in the context of the optimal transportation problem or, by contrast, a random flow, known to be similar to the electrical current flow if the random-walk is reversible. Moreover, a source-targetcoupling can be retrieved from this flow, offering an optimal assignment to the transportation problem. This algorithm is described in the first part of this article and then illustrated with case studies.
Regression Models for Identifying Noise Sources in Magnetic Resonance Images
Zhu, Hongtu; Li, Yimei; Ibrahim, Joseph G.; Shi, Xiaoyan; An, Hongyu; Chen, Yashen; Gao, Wei; Lin, Weili; Rowe, Daniel B.; Peterson, Bradley S.
2009-01-01
Stochastic noise, susceptibility artifacts, magnetic field and radiofrequency inhomogeneities, and other noise components in magnetic resonance images (MRIs) can introduce serious bias into any measurements made with those images. We formally introduce three regression models including a Rician regression model and two associated normal models to characterize stochastic noise in various magnetic resonance imaging modalities, including diffusion-weighted imaging (DWI) and functional MRI (fMRI). Estimation algorithms are introduced to maximize the likelihood function of the three regression models. We also develop a diagnostic procedure for systematically exploring MR images to identify noise components other than simple stochastic noise, and to detect discrepancies between the fitted regression models and MRI data. The diagnostic procedure includes goodness-of-fit statistics, measures of influence, and tools for graphical display. The goodness-of-fit statistics can assess the key assumptions of the three regression models, whereas measures of influence can isolate outliers caused by certain noise components, including motion artifacts. The tools for graphical display permit graphical visualization of the values for the goodness-of-fit statistic and influence measures. Finally, we conduct simulation studies to evaluate performance of these methods, and we analyze a real dataset to illustrate how our diagnostic procedure localizes subtle image artifacts by detecting intravoxel variability that is not captured by the regression models. PMID:19890478
Automated Cryocooler Monitor and Control System
NASA Technical Reports Server (NTRS)
Britcliffe, Michael J.; Hanscon, Theodore R.; Fowler, Larry E.
2011-01-01
A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.
Pupils' over-reliance on linearity: a scholastic effect?
Van Dooren, Wim; De Bock, Dirk; Janssens, Dirk; Verschaffel, Lieven
2007-06-01
From upper elementary education on, children develop a tendency to over-use linearity. Particularly, it is found that many pupils assume that if a figure enlarges k times, the area enlarges k times too. However, most research was conducted with traditional, school-like word problems. This study examines whether pupils also over-use linearity if non-linear problems are embedded in meaningful, authentic performance tasks instead of traditional, school-like word problems, and whether this experience influences later behaviour. Ninety-three sixth graders from two primary schools in Flanders, Belgium. Pupils received a pre-test with traditional word problems. Those who made a linear error on the non-linear area problem were subjected to individual interviews. They received one new non-linear problem, in the S-condition (again a traditional, scholastic word problem), D-condition (the same word problem with a drawing) or P-condition (a meaningful performance-based task). Shortly afterwards, pupils received a post-test, containing again a non-linear word problem. Most pupils from the S-condition displayed linear reasoning during the interview. Offering drawings (D-condition) had a positive effect, but presenting the problem as a performance task (P-condition) was more beneficial. Linear reasoning was nearly absent in the P-condition. Remarkably, at the post-test, most pupils from all three groups again applied linear strategies. Pupils' over-reliance on linearity seems partly elicited by the school-like word problem format of test items. Pupils perform much better if non-linear problems are offered as performance tasks. However, a single experience does not change performances on a comparable word problem test afterwards.
Ozone and UV-B variations at Ispra from 1993 to 1997
NASA Astrophysics Data System (ADS)
Cappellani, F.; Kochler, C.
An analysis of the variability of the total ozone column at Ispra (Italy) has been performed to ascertain if, even in a short-time interval of 5 years (1993-1997), a decline of the monthly mean ozone values could be demonstrated. A linear fit of the data displays a decrease of 0.21% per year with a mean value equal to 319±2 D.U. and an amplitude of the annual cycle of about 10% of the mean. A linear regression of the surface monthly mean ozone values has also been performed showing a decreasing trend (-1% per year) that could contribute, even if for a very small amount, to the decline of the total ozone values. Ispra monthly mean total ozone data have been compared with those of three stations located within 2° latitude and 3° longitude from Ispra (Haute Provence, Hohenpeissenberg and Arosa). A linear fit of the data shows some discrepancies in the ozone changes, which can be attributed to the limited length of the observational period. An analysis has been performed to verify if the variation of ozone at Ispra is in agreement with that of the solar UV measured at a wavelength (305 nm) where the ozone absorption is still remarkable. The results, taken at a fixed solar zenith angle of 68°, show a clear anticorrelation between the monthly mean values of UV and the corresponding values of the total ozone column; the linear fit of the UV data displays an increase of 2.0% per year, much higher than expected from the ozone decrease, and a mean value of 1.4±0.1 mW m -2 nm -1.
Seeing a Blush on the Visible and Invisible Spectrum: A Functional Thermal Infrared Imaging Study
Ioannou, Stephanos; Morris, Paul H.; Baker, Marc; Reddy, Vasudevi; Gallese, Vittorio
2017-01-01
So far blushing has been examined in the context of a negative rather than a positive reinforcement where visual displays of a blush were based on subjective measures. The current study used infrared imaging to measure thermal patterns of the face while with the use of a video camera quantified on the visible spectrum alterations in skin color related to a compliment. To elicit a blush a three-phase dialog was adopted ending or starting with a compliment on a female sample (N = 22). When the dialog ended with a compliment results showed a linear increase in temperature for the cheek, and forehead whereas for the peri-orbital region a linear decrease was observed. The compliment phase marked the highest temperature on the chin independent of whether or not the experiment started with a compliment contrary to other facial regions, which did not show a significant change when the experiment started with a compliment. Analyses on the visible spectrum showed that skin pigmentation was getting deep red in the compliment condition compared to the serious and social dialog conditions for both the forehead and the cheeks. No significant association was observed between temperature values and erythrocyte displays on the forehead and cheek. Heat is the physiological product of an arousing social scenario, however, preconceived notions about blushing propensity seem to drive erythrocyte displays and not necessarily conscious awareness of somatic sensations. PMID:29163105
Recent advances in a linear micromirror array for high-resolution projection
NASA Astrophysics Data System (ADS)
Picard, Francis; Doucet, Michel; Niall, Keith K.; Larouche, Carl; Savard, Maxime; Crisan, Silviu; Thibault, Simon; Jerominek, Hubert
2004-05-01
The visual displays of contemporary military flight simulators lack adequate definition to represent scenes in basic fast-jet fighter tasks. For example, air-to-air and air-to-ground targets are not projected with sufficient contrast and resolution for a pilot to perceive aspect, aspect rate and object detail at real world slant ranges. Simulator display geometries require the development of ultra-high resolution projectors with greater than 20 megapixel resolution at 60 Hz frame rate. A new micromirror device has been developed to address this requirement; it is able to modulate light intensity in an analog fashion with switching times shorter than 5 μs. When combined with a scanner, a laser and Schlieren optics, a linear array of these flexible micromirrors can display images composed of thousands of lines at a frame rate of 60 Hz. Recent results related to evaluation of this technology for high resolution projection are presented. Alternate operation modes for light modulation with flexible micromirrors are proposed. The related importance of controlling the residual micromirror curvature is discussed and results of experiments investigating the use of the deposition pressure to achieve such control are reported. Moreover, activities aiming at minimizing the micromirror response time and, so doing, maximizing the number of image columns per image frame are discussed. Finally, contrast measurement and estimate of the contrast limit achievable with the flexible micromirror technology are presented. All reported activities support the development of a fully addressable 2000-element micromirror array.
Control Surface Interaction Effects of the Active Aeroelastic Wing Wind Tunnel Model
NASA Technical Reports Server (NTRS)
Heeg, Jennifer
2006-01-01
This paper presents results from testing the Active Aeroelastic Wing wind tunnel model in NASA Langley s Transonic Dynamics Tunnel. The wind tunnel test provided an opportunity to study aeroelastic system behavior under combined control surface deflections, testing for control surface interaction effects. Control surface interactions were observed in both static control surface actuation testing and dynamic control surface oscillation testing. The primary method of evaluating interactions was examination of the goodness of the linear superposition assumptions. Responses produced by independently actuating single control surfaces were combined and compared with those produced by simultaneously actuating and oscillating multiple control surfaces. Adjustments to the data were required to isolate the control surface influences. Using dynamic data, the task increases, as both the amplitude and phase have to be considered in the data corrections. The goodness of static linear superposition was examined and analysis of variance was used to evaluate significant factors influencing that goodness. The dynamic data showed interaction effects in both the aerodynamic measurements and the structural measurements.
Li, Zhenzhen; Xin, Yanmei; Zhang, Zhonghai; Wu, Hongjun; Wang, Peng
2015-01-01
One-dimensional nanocomposites of metal-oxide and noble metal were expected to present superior performance for nonenzymatic glucose detection due to its good conductivity and high catalytic activity inherited from noble metal and metal oxide respectively. As a proof of concept, we synthesized gold and copper oxide (Au/CuO) composite with unique one-dimensional nanocauliflowers structure. Due to the nature of the synthesis method, no any foreign binder was needed in keeping either Au or CuO in place. To the best of our knowledge, this is the first attempt in combining metal oxide and noble metal in a binder-free style for fabricating nonenzymatic glucose sensor. The Au/CuO nanocauliflowers with large electrochemical active surface and high electrolyte contact area would promise a wide linear range and high sensitive detection of glucose with good stability and reproducibility due to its good electrical conductivity of Au and high electrocatalytic activity of CuO. PMID:26068705
Diffusive Public Goods and Coexistence of Cooperators and Cheaters on a 1D Lattice
Scheuring, István
2014-01-01
Many populations of cells cooperate through the production of extracellular materials. These materials (enzymes, siderophores) spread by diffusion and can be applied by both the cooperator and cheater (non-producer) cells. In this paper the problem of coexistence of cooperator and cheater cells is studied on a 1D lattice where cooperator cells produce a diffusive material which is beneficial to the individuals according to the local concentration of this public good. The reproduction success of a cell increases linearly with the benefit in the first model version and increases non-linearly (saturates) in the second version. Two types of update rules are considered; either the cooperative cell stops producing material before death (death-production-birth, DpB) or it produces the common material before it is selected to die (production-death-birth, pDB). The empty space is occupied by its neighbors according to their replication rates. By using analytical and numerical methods I have shown that coexistence of the cooperator and cheater cells is possible although atypical in the linear version of this 1D model if either DpB or pDB update rule is assumed. While coexistence is impossible in the non-linear model with pDB update rule, it is one of the typical behaviors in case of the non-linear model with DpB update rule. PMID:25025985
Linear and nonlinear methods in modeling the aqueous solubility of organic compounds.
Catana, Cornel; Gao, Hua; Orrenius, Christian; Stouten, Pieter F W
2005-01-01
Solubility data for 930 diverse compounds have been analyzed using linear Partial Least Square (PLS) and nonlinear PLS methods, Continuum Regression (CR), and Neural Networks (NN). 1D and 2D descriptors from MOE package in combination with E-state or ISIS keys have been used. The best model was obtained using linear PLS for a combination between 22 MOE descriptors and 65 ISIS keys. It has a correlation coefficient (r2) of 0.935 and a root-mean-square error (RMSE) of 0.468 log molar solubility (log S(w)). The model validated on a test set of 177 compounds not included in the training set has r2 0.911 and RMSE 0.475 log S(w). The descriptors were ranked according to their importance, and at the top of the list have been found the 22 MOE descriptors. The CR model produced results as good as PLS, and because of the way in which cross-validation has been done it is expected to be a valuable tool in prediction besides PLS model. The statistics obtained using nonlinear methods did not surpass those got with linear ones. The good statistic obtained for linear PLS and CR recommends these models to be used in prediction when it is difficult or impossible to make experimental measurements, for virtual screening, combinatorial library design, and efficient leads optimization.
NASA Astrophysics Data System (ADS)
Bressan, José Divo; Liewald, Mathias; Drotleff, Klaus
2017-10-01
Forming limit strain curves of conventional aluminium alloy AA6014 sheets after loading with non-linear strain paths are presented and compared with D-Bressan macroscopic model of sheet metal rupture by critical shear stress criterion. AA6014 exhibits good formability at room temperature and, thus, is mainly employed in car body external parts by manufacturing at room temperature. According to Weber et al., experimental bi-linear strain paths were carried out in specimens with 1mm thickness by pre-stretching in uniaxial and biaxial directions up to 5%, 10% and 20% strain levels before performing Nakajima testing experiments to obtain the forming limit strain curves, FLCs. In addition, FLCs of AA6014 were predicted by employing D-Bressan critical shear stress criterion for bi-linear strain path and comparisons with the experimental FLCs were analyzed and discussed. In order to obtain the material coefficients of plastic anisotropy, strain and strain rate hardening behavior and calibrate the D-Bressan model, tensile tests, two different strain rate on specimens cut at 0°, 45° and 90° to the rolling direction and also bulge test were carried out at room temperature. The correlation of experimental bi-linear strain path FLCs is reasonably good with the predicted limit strains from D-Bressan model, assuming equivalent pre-strain calculated by Hill 1979 yield criterion.
Ouyang, Ruizhuo; Zhang, Wangyao; Zhou, Shilin; Xue, Zi-Ling; Xu, Lina; Gu, Yingying; Miao, Yuqing
2013-12-15
We report here the successful fabrication of an improved Bi film wrapped single walled carbon nanotubes modified glassy carbon electrode (Bi/SWNTs/GCE) as a highly sensitive platform for ultratrace Cr(VI) detection through catalytic adsorptive cathodic stripping voltammetry (AdCSV). The introduction of negatively charged SWNTs extraordinarily decreased the size of Bi particles to nanoscale due to electrostatic interaction which made Bi(III) cations easily attracted onto the surface of SWNTs in good order, leading to higher quality of Bi film deposition. The obtained Bi/SWNTs composite was well characterized with electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), the static water contact angle and the voltammetric measurements. The results demonstrates the improvements in the quality of Bi film deposited on the surface of SWNTs such as faster speed of electron transfer, more uniform and smoother morphology, better hydrophilicity and higher stripping signal. Using diethylene triaminepentaacetic acid (DTPA) as complexing ligand, the fabricated electrode displays a well-defined and highly sensitive peak for the reduction of Cr(III)-DTPA complex at -1.06 V ( vs . Ag/AgCl) with a linear concentration range of 0-25 nM and a fairly low detection limit of 0.036 nM. No interference was found in the presence of coexisting ions, and good recoveries were achieved for the analysis of a river sample. In comparison to previous approaches using Bi film modified GCE, the newly designed electrode exhibits better reproducibility and repeatability towards aqueous detection of trace Cr(VI) and appears to be very promising as the basis of a highly sensitive and selective voltammetric procedure for Cr(VI) detection at trace level in real samples.
Sun, Zhoumin; Fu, Haiying; Deng, Liu; Wang, Jianxiu
2013-01-25
In this paper, we fabricate a sensitive and stable amperometric UA amperometric biosensor using nanobiocomposite derived from thionine modified graphene oxide in this study. A simple wet-chemical strategy for synthesis of thionine-graphene oxide hybrid nanosheets (T-GOs) through π-π stacking has been demonstrated. Various techniques, such as UV-vis absorption spectroscopy, X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), atomic force microscopy (AFM) and electrochemistry have been utilized to characterize the formation of the T-GOs. Due to the synergistic effect between thionine and graphene oxide, the nanosheets exhibited excellent performance toward H(2)O(2) reduction. The incorporation of thionine onto graphene oxide surface resulted in more than a twice increase in the amperometric response to H(2)O(2) of the thionine modified electrode. The as-formed T-GOs also served as a biocompatible matrix for enzyme assembly and a mediator to facilitate the electron transfer between the enzyme and the electrode. Using UOx as a model system, we have developed a simple and effective sensing platform for assay of uric acid at physiological levels. UA has been successfully detected at -0.1 V without any interference due to other electroactive compounds at physiological levels of glucose (5 mM), ascorbic acid (0.1 mM), noradrenalin (0.1 mM), and dopamine (0.1 mM). The response displays a good linear range from 0.02 to 4.5 mM with detection limit 7 μM. The application of this modified electrode in blood and urine UA exhibited a good performance. The robust and advanced hybrid materials might hold great promise in biosensing, energy conversion, and biomedical and electronic systems. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liang, Beibei; Wang, Baiyan; Ma, Qiujuan; Xie, Caixia; Li, Xian; Wang, Suiping
2018-03-01
Biological thiols, like cysteine (Cys), homocysteine (Hcy) and glutathione (GSH), play crucial roles in biological systems and in lysosomal processes. Highly selective probes for detecting biological thiols in lysomes of living cells are rare. In this work, a lysosome-targetable turn-on fluorescent probe for the detection of thiols in living cells was designed and synthesized based on a 1,8-naphthalimide derivative. The probe has a 4-(2-aminoethyl)morpholine unit as a lysosome-targetable group and an acrylate group as the thiol recognition unit as well as a fluorescence quencher. In the absence of biothiols, the probe displayed weak fluorescence due to the photoinduced electron transfer (PET) process. Upon the addition of biothiols, the probe exhibited an enhanced fluorescence emission centered at 550 nm due to cleavage of the acrylate moiety. The probe had high selectivity toward biothiols. Moreover, the probe features fast response time, excitation in the visible region and ability of working in a wide pH range. The linear response range covers a concentration range of Cys from 1.5 × 10- 7 to 1.0 × 10- 5 mol·L- 1 and the detection limit is 6.9 × 10- 8 mol·L- 1 for Cys. The probe has been successfully applied to the confocal imaging of biothiols in lysosomes of A549 cells with low cell toxicity. Furthermore, the method was successfully applied to the determination of thiols in a complex multicomponent mixture such as human serum, which suggests our proposed method has great potential for diagnostic purposes. All of such good properties prove it can be used to monitor biothiols in lysosomes of living cells and to be a good fluorescent probe for the selective detection of thiols.
Boissin, Constance; Blom, Lisa; Wallis, Lee; Laflamme, Lucie
2017-02-01
Mobile health has promising potential in improving healthcare delivery by facilitating access to expert advice. Enabling experts to review images on their smartphone or tablet may save valuable time. This study aims at assessing whether images viewed by medical specialists on handheld devices such as smartphones and tablets are perceived to be of comparable quality as when viewed on a computer screen. This was a prospective study comparing the perceived quality of 18 images on three different display devices (smartphone, tablet and computer) by 27 participants (4 burn surgeons and 23 emergency medicine specialists). The images, presented in random order, covered clinical (dermatological conditions, burns, ECGs and X-rays) and non-clinical subjects and their perceived quality was assessed using a 7-point Likert scale. Differences in devices' quality ratings were analysed using linear regression models for clustered data adjusting for image type and participants' characteristics (age, gender and medical specialty). Overall, the images were rated good or very good in most instances and more so for the smartphone (83.1%, mean score 5.7) and tablet (78.2%, mean 5.5) than for a standard computer (70.6%, mean 5.2). Both handheld devices had significantly higher ratings than the computer screen, even after controlling for image type and participants' characteristics. Nearly all experts expressed that they would be comfortable using smartphones (n=25) or tablets (n=26) for image-based teleconsultation. This study suggests that handheld devices could be a substitute for computer screens for teleconsultation by physicians working in emergency settings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Steiger, S; Capodeanu-Nägler, A; Gershman, S N; Weddle, C B; Rapkin, J; Sakaluk, S K; Hunt, J
2015-12-01
Indirect genetic benefits derived from female mate choice comprise additive (good genes) and nonadditive genetic benefits (genetic compatibility). Although good genes can be revealed by condition-dependent display traits, the mechanism by which compatibility alleles are detected is unclear because evaluation of the genetic similarity of a prospective mate requires the female to assess the genotype of the male and compare it to her own. Cuticular hydrocarbons (CHCs), lipids coating the exoskeleton of most insects, influence female mate choice in a number of species and offer a way for females to assess genetic similarity of prospective mates. Here, we determine whether female mate choice in decorated crickets is based on male CHCs and whether it is influenced by females' own CHC profiles. We used multivariate selection analysis to estimate the strength and form of selection acting on male CHCs through female mate choice, and employed different measures of multivariate dissimilarity to determine whether a female's preference for male CHCs is based on similarity to her own CHC profile. Female mating preferences were significantly influenced by CHC profiles of males. Male CHC attractiveness was not, however, contingent on the CHC profile of the choosing female, as certain male CHC phenotypes were equally attractive to most females, evidenced by significant linear and stabilizing selection gradients. These results suggest that additive genetic benefits, rather than nonadditive genetic benefits, accrue to female mate choice, in support of earlier work showing that CHC expression of males, but not females, is condition dependent. © 2015 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2015 European Society For Evolutionary Biology.
Zhou, Shilin; Xue, Zi-Ling; Xu, Lina; Gu, Yingying; Miao, Yuqing
2014-01-01
We report here the successful fabrication of an improved Bi film wrapped single walled carbon nanotubes modified glassy carbon electrode (Bi/SWNTs/GCE) as a highly sensitive platform for ultratrace Cr(VI) detection through catalytic adsorptive cathodic stripping voltammetry (AdCSV). The introduction of negatively charged SWNTs extraordinarily decreased the size of Bi particles to nanoscale due to electrostatic interaction which made Bi(III) cations easily attracted onto the surface of SWNTs in good order, leading to higher quality of Bi film deposition. The obtained Bi/SWNTs composite was well characterized with electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), the static water contact angle and the voltammetric measurements. The results demonstrates the improvements in the quality of Bi film deposited on the surface of SWNTs such as faster speed of electron transfer, more uniform and smoother morphology, better hydrophilicity and higher stripping signal. Using diethylene triaminepentaacetic acid (DTPA) as complexing ligand, the fabricated electrode displays a well-defined and highly sensitive peak for the reduction of Cr(III)-DTPA complex at −1.06 V (vs. Ag/AgCl) with a linear concentration range of 0–25 nM and a fairly low detection limit of 0.036 nM. No interference was found in the presence of coexisting ions, and good recoveries were achieved for the analysis of a river sample. In comparison to previous approaches using Bi film modified GCE, the newly designed electrode exhibits better reproducibility and repeatability towards aqueous detection of trace Cr(VI) and appears to be very promising as the basis of a highly sensitive and selective voltammetric procedure for Cr(VI) detection at trace level in real samples. PMID:24771881
Meng, Annette; Siren, Anu
2012-11-01
Ageing in general is associated with functional decline that may have an adverse effect on driving. Nevertheless, older drivers have been found to show good judgement and to self-regulate their driving, which may enable them to continue driving safely despite functional decline. The process of the self-monitoring of driving ability and the awareness of functional decline, and its association with the self-regulation of driving is, however, not fully understood. The aim of the present study was to examine the perceived changes in driving skills, the discomfort experienced in driving, and the self-regulation of driving as measured by the avoidance of certain driving situations by older drivers with different levels of self-rated cognitive problems. Eight hundred and forty Danish drivers aged 75-95 completed a structured telephone interview. The results showed that the recognition of cognitive problems was associated with an experience of improvement in higher level driving skills but also of a decline in lower level driving skills. Moreover, cognitive problems recognised by drivers were associated with discomfort in, and avoidance of, driving situations. Finally, a linear relationship between discomfort in driving and avoidance was found and this tended to be stronger for drivers recognising cognitive problems. The results indicate that older drivers who recognise problems with cognitive functions display good self-assessment of changes in their driving skills. In addition, the results suggest that driving-related discomfort is an important factor affecting the self-regulation of driving. Finally, the findings indicate that driving-related discomfort functions as an indirect self-monitoring of driving ability and may contribute to the safe driving performance of Danish older drivers. Copyright © 2012 Elsevier Ltd. All rights reserved.
HOW TO MANAGE DATA BADLY (PART 1 & 2)
In a landmark article in The American Statistician, Howard Wainer (1994) presented ideas for (a) "How to Display Data Badly," wherein good data are ruined by bad graphics. Wainer presumed too much. In this essay, I extend his concept by presenting ideas and examples of how scient...
ERIC Educational Resources Information Center
Bernstein, Alan; Alan, Michael
2009-01-01
A good high school cultural arts program puts students' creative talents on display, allows them to demonstrate innovative thinking, and gives them direct and indirect exposure to careers in the cultural arts. A truly outstanding program goes even further to emulate real-world authentic artistic experiences and to create multidisciplinary artistic…
Stochastic Swift-Hohenberg Equation with Degenerate Linear Multiplicative Noise
NASA Astrophysics Data System (ADS)
Hernández, Marco; Ong, Kiah Wah
2018-03-01
We study the dynamic transition of the Swift-Hohenberg equation (SHE) when linear multiplicative noise acting on a finite set of modes of the dominant linear flow is introduced. Existence of a stochastic flow and a local stochastic invariant manifold for this stochastic form of SHE are both addressed in this work. We show that the approximate reduced system corresponding to the invariant manifold undergoes a stochastic pitchfork bifurcation, and obtain numerical evidence suggesting that this picture is a good approximation for the full system as well.
Evolution of optimal Hill coefficients in nonlinear public goods games.
Archetti, Marco; Scheuring, István
2016-10-07
In evolutionary game theory, the effect of public goods like diffusible molecules has been modelled using linear, concave, sigmoid and step functions. The observation that biological systems are often sigmoid input-output functions, as described by the Hill equation, suggests that a sigmoid function is more realistic. The Michaelis-Menten model of enzyme kinetics, however, predicts a concave function, and while mechanistic explanations of sigmoid kinetics exist, we lack an adaptive explanation: what is the evolutionary advantage of a sigmoid benefit function? We analyse public goods games in which the shape of the benefit function can evolve, in order to determine the optimal and evolutionarily stable Hill coefficients. We find that, while the dynamics depends on whether output is controlled at the level of the individual or the population, intermediate or high Hill coefficients often evolve, leading to sigmoid input-output functions that for some parameters are so steep to resemble a step function (an on-off switch). Our results suggest that, even when the shape of the benefit function is unknown, biological public goods should be modelled using a sigmoid or step function rather than a linear or concave function. Copyright © 2016 Elsevier Ltd. All rights reserved.
Advances in diagnostic ultrasonography.
Reef, V B
1991-08-01
A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.
2011-11-30
does not display a currently valid OMB control number. 1. REPORT DATE 30 NOV 2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4...Appropriate site variables (for purposes of accurate modeling); • Potential queues caused by the access control facility to the south parking...to LoS D LoS Control Delay/Vehicle (sec) Qualitative Description A ≤10 Good progression, few stops, and short cycle lengths B >10 - 20 Good
STS-132 crew during their MSS/SIMP EVA3 OPS 4 training
2010-01-28
JSC2010-E-014957 (28 Jan. 2010) --- NASA astronaut Michael Good, STS-132 mission specialist, uses virtual reality hardware in the Space Vehicle Mock-up Facility at NASA's Johnson Space Center to rehearse some of his duties on the upcoming mission to the International Space Station. This type of virtual reality training allows the astronauts to wear a helmet and special gloves while looking at computer displays simulating actual movements around the various locations on the station hardware with which they will be working. David Homan assisted Good.
Porous Ceramic Cures at Moderate Temperatures, Is Good Heat Insulator
NASA Technical Reports Server (NTRS)
Eubanks, Alfred G.; Hunkeler, Ronald E.
1965-01-01
The problem: To develop a foamed-in-place refractory material that would provide good thermal insulation, mechanical support, and vibration shielding for enclosed objects at temperatures up to 30000 F. The preparation of conventional foamed refractory materials required long curing times (as much as 48 hours) and high temperatures (at least 700 F), rendering such materials unusable for in-place potting of heat-sensitive components. The solution: A foamed ceramic material that has the requisite thermal insulation and strength, and also displays other properties that suggest a wide range of applications.
Application of the weibull distribution function to the molecular weight distribution of cellulose
A. Broido; Hsiukang Yow
1977-01-01
The molecular weight distribution of a linear homologous polymer is usually obtained empirically for any particular sample. Sample-to-sample comparisons are made in terms of the weight- or number-average molecular weights and graphic displays of the distribution curves. Such treatment generally precludes data interpretations in which a distribution can be described in...
ERIC Educational Resources Information Center
Korallo, Liliya; Foreman, Nigel; Boyd-Davis, Stephen; Moar, Magnus; Coulson, Mark
2012-01-01
Single linear virtual timelines have been used effectively with undergraduates and primary school children to convey the chronological ordering of historical items, improving on PowerPoint and paper/textual displays. In the present study, a virtual environment (VE) consisting of three parallel related timelines (world history and the histories of…
Developing Integrated Arts Curriculum in Hong Kong: Chaos Theory at Work?
ERIC Educational Resources Information Center
Wong, Marina
2013-01-01
This article reports the development of integrated arts curriculum in two Hong Kong secondary schools over a 9-year period. Initial findings display a range of individual responses to educational change that are both non-predictable and non-linear. Chaos theory is used to explain these varied responses in terms of bifurcations. The findings of…
Cholesteric Liquid Crystal Based Reflex Color Reflective Displays
NASA Astrophysics Data System (ADS)
Khan, Asad
2012-02-01
Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer products and related markets. This is a development that spans a wide space of highly technical development and fundamental science to products and commercialization to enable the entry of the technology into consumer markets.
Yagil, Dana; Shnapper-Cohen, Moran
2016-10-01
The emotions expressed by physicians in medical encounters have significant impact on health outcomes and patient satisfaction. This study explored how physicians' regulation of displayed emotions affects patients' satisfaction, under low and high levels of patient distress and length of physician-patient acquaintance. Questionnaires were administered to 46 physicians and 230 of their patients (before and after the medical encounter) in outpatient clinics of two hospitals. Data were analyzed with hierarchical linear modeling which takes the nested data structure into account. We found a significant interaction effect of physician regulation of displayed emotions and patient distress on satisfaction: When distress was high, physician regulation of emotions was negatively related to patient satisfaction. The results also show a significant interaction effect of physician regulation of displayed emotions and length of physician-patient acquaintance: With a longer acquaintance, physician regulation of emotions was negatively related to patient satisfaction. The effect of the physicians' emotional display on patient satisfaction depends on contextual factors, such as patient distress and length of physician-patient acquaintance, which affect patients' emotional needs and expectations. When patients have high emotional involvement in the encounter it is suggested that physicians consider presenting genuine emotions to patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
New pyrazolopyridine analogs: Synthesis, antimicrobial, antiquorum-sensing and antitumor screening.
El-Gohary, N S; Shaaban, M I
2018-05-25
New pyrazolopyridine analogs were prepared and tested for antimicrobial efficacy toward Staphylococcus aureus, Bacillus cereus, Escherichia coli, Pseudomonas aeruginosa, Candida albicans, Aspergillus fumigatus and Aspergillus flavus. Results revealed that compound 6 has prominent and broad spectrum antimicrobial activity. Compound 8 showed good antibacterial efficacy over the four tested bacterial strains. In addition, compounds 2-4 displayed interesting efficacy over S. aureus, B. cereus and P. aeruginosa as well as moderate efficacy toward E. coli, C. albicans, A. fumigatus and A. flavus. Furthermore, compounds 9 and 10 exhibited interesting efficacy over P. aeruginosa. Antiquorum-sensing efficacy of the same analogs toward Chromobacterium violaceum was also examined, whereas compounds 3, 4 and 6 displayed acceptable activity. In vitro antitumor assay of the new pyrazolopyridines toward liver (HepG2), breast (MCF-7) and cervix (Hela) cancer cells illustrated that compounds 2 and 5 have the highest antitumor activity over the three cell lines. Moreover, compound 4 exhibited interesting efficacy on all tested cell lines, whereas compound 7 showed good activity on MCF-7 cells. The most active in vitro antitumor analogs, 2, 4, 5 and 7 were assessed for in vivo antitumor efficacy on Ehrlich ascites carcinoma (EAC) cells, whereas compound 5 displayed the highest efficacy. In addition, cytotoxicity testing toward W138 and WISH normal cells revealed that all tested analogs are less cytotoxic than doxorubicin. The new analogs were evaluated for DNA-binding affinity, whereas compounds 2, 4 and 5 displayed the highest affinity. In silico studies concluded that all the new pyrazolopyridines are foreseen to have excellent oral absorption. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Ni-NiO core-shell inverse opal electrodes for supercapacitors.
Kim, Jae-Hun; Kang, Soon Hyung; Zhu, Kai; Kim, Jin Young; Neale, Nathan R; Frank, Arthur J
2011-05-14
A general template-assisted electrochemical approach was used to synthesize three-dimensional ordered Ni core-NiO shell inverse opals (IOs) as electrodes for supercapacitors. The Ni-NiO IO electrodes displayed pseudo-capacitor behavior, good rate capability and cycling performance. © The Royal Society of Chemistry 2011
An Experimental Health Education Program: Effects on Urban Primary Students.
ERIC Educational Resources Information Center
Andrews, Richard L.; Hearne, Jill T.
1986-01-01
Presents findings of an evaluation of a health education program for primary school students of low SES. Related findings to two dependent measures--attitudes toward smoking and knowledge about smoking and health. Reports that program participants displayed more positive attitudes toward good health practices than did non-participating control…
NASA Astrophysics Data System (ADS)
Tan, Yuan; Jing, Lijing; Ding, Yonghong; Wei, Tianxin
2015-07-01
This work aimed to prepare a novel double-layer structure molecularly imprinted polymer film (MIF) on the surface plasmon resonance (SPR) sensor chips for detection of testosterone in aqueous media. The film was synthesized by in-situ UV photo polymerization. Firstly, the modification of gold surface of SPR chip was performed by 1-dodecanethiol. Then double-layer MIF was generated on the 1-dodecanethiol modified gold surface. The non-modified and imprinted surfaces were characterized by atomic force microscopy (AFM), fourier transform infrared (FTIR) spectroscopy and contact angle measurements. Analysis of SPR spectroscopy showed that the imprinted sensing film displayed good selectivity for testosterone compared to other analogues and the non-imprinted polymer film (NIF). Within the concentrations range of 1 × 10-12-1 × 10-8 mol/L, the coupling angle changes of SPR were linear with the negative logarithm of testosterone concentrations (R2 = 0.993). Based on a signal/noise ratio of three, the detection limit was estimated to be 10-12 mol/L. Finally, the developed MIF was successfully applied to the seawater detection of testosterone. The results in the experiments suggested that a combination of SPR sensing with MIF was a promising alternative method for detection of testosterone in aqueous media.
Townley, Greg; Miller, Henry; Kloos, Bret
2013-09-01
Although an extensive body of literature highlights the important role of social support for individuals with psychiatric disabilities, definitions of support tend to be restricted-focusing on intimate relationships such as friend and family networks and ignoring the role of casual relationships existing naturally in the community. This mixed-methods study of 300 consumers of mental health services in the Southeastern US aims to better understand the impact of community supports, termed distal supports, on community integration and recovery from mental illness. Qualitative content analysis, tests of group mean differences, and hierarchical linear regression analyses revealed the following: (1) participants primarily reported receiving tangible support (e.g., free medication/discounted goods) from distal supports rather than emotional support (e.g., displays of warmth/affection) or informational support (e.g., provision of advice); (2) women and older participants reported more distal supports than men or younger participants; and (3) distal supports played a unique role in predicting community integration and recovery even after accounting for the influence of traditional support networks. Results highlight the importance of considering diverse types of social support in naturally occurring settings when designing treatment plans and interventions aimed at encouraging community participation and adaptive functioning for individuals with psychiatric disabilities.
Balasubramanian, Paramasivam; Settu, Ramki; Chen, Shen-Ming; Chen, Tse-Wei; Sharmila, Ganapathi
2018-08-15
Herein, we report a novel, disposable electrochemical sensor for the detection of nitrite ions in food samples based on the sonochemical synthesized orthorhombic CaFe 2 O 4 (CFO) clusters modified screen printed electrode. As synthesized CFO clusters were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transformer infrared spectroscopy (FT-IR), Thermogravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and amperometry (i-t). Under optimal condition, the CFO modified electrode displayed a rapid current response to nitrite, a linear response range from 0.016 to 1921 µM associated with a low detection limit 6.6 nM. The suggested sensor also showed the excellent sensitivity of 3.712 μA μM -1 cm -2 . Furthermore, a good reproducibility, long-term stability and excellent selectivity were also attained on the proposed sensor. In addition, the practical applicability of the sensor was investigated via meat samples, tap water and drinking water, and showed desirable recovery rate, representing its possibilities for practical application. Copyright © 2018 Elsevier Inc. All rights reserved.
Xie, Jian-De; Gu, Siyong; Zhang, Houan
2017-09-21
This work outlines a synthetic strategy inducing the microwave-assisted synthesis of palladium (Pd) nanocrystals on a graphite sphere (GS) and reduced graphene oxide (rGO) supports, forming the Pd catalysts for non-enzymatic glucose oxidation reaction (GOR). The pulse microwave approach takes a short period (i.e., 10 min) to fast synthesize Pd nanocrystals onto a carbon support at 150 °C. The selection of carbon support plays a crucial role in affecting Pd particle size and dispersion uniformity. The robust design of Pd-rGO catalyst electrode displays an enhanced electrocatalytic activity and sensitivity toward GOR. The enhanced performance is mainly attributed to the synergetic effect that combines small crystalline size and two-dimensional conductive support, imparting high accessibility to non-enzymatic GOR. The rGO sheets serve as a conductive scaffold, capable of fast conducting electron. The linear plot of current response versus glucose concentration exhibits good correlations within the range of 1-12 mM. The sensitivity of the Pd-rGO catalyst is significantly enhanced by 3.7 times, as compared to the Pd-GS catalyst. Accordingly, the Pd-rGO catalyst electrode can be considered as a potential candidate for non-enzymatic glucose biosensor.
Microstructure and Corrosion Behavior of Laser Synthesized Cobalt Based Powder on Ti-6Al-4V
NASA Astrophysics Data System (ADS)
Adesina, O. S.; Popoola, A. P. I.; Pityana, S. L.; Oloruntoba, D. T.
2018-05-01
The corrosion behavior of titanium alloys when used for various dynamic offshore components has been a major concern of titanium drilling risers in deepwater energy extraction. A way of achieving specified requirement is the development of coatings suitable to protect the base material against corrosion. In this work, laser cladding technique which is known as a leading edge due to its distinctive properties and outcomes was used in synthesizing Co-based powder on titanium alloy. The processing parameters used were laser power of 900W; scan speed of 0.6 to 1.2 m/min; powderfeedrate1.0g/min;beamspotsize3mm;gasflowrate1.2L/min.The effects of cobalt addition and laser parameters on corrosion behavior of laser clad Ti6AL4V coating in 0.5M sulfuric medium were investigated using linear potentiodynamic polarization. The changes in microstructure and corrosion behavior were analyzed using scanning electron microscopy (SEM) while the X –ray diffraction (XRD) indicates the intermetallics in the coatings. Results showed that the coatings displayed good metallurgical bonding with dendritic formations between the coatings and the substrate. The anodic current density increased with lower scan speed. However, the corrosion current densities of laser-clad samples were lower than Ti6Al4V alloy.
Sharma, Jitendra Kumar; Srivastava, Pratibha; Ameen, Sadia; Akhtar, M Shaheer; Singh, Gurdip; Yadava, Sudha
2016-06-15
The leaf extract of Azadirachta indica (Neem) plant was utilized as reducing agent for the green synthesis of Mn3O4 nanoparticles (NPs). The crystalline analysis demonstrated the typical tetragonal hausmannite crystal structure of Mn3O4, which confirmed the formation of Mn3O4 NPs without the existence of other oxides. Green synthesized Mn3O4 NPs were applied for the catalytic thermal decomposition of ammonium perchlorate (AP) and as working electrode for fabricating the chemical sensor. The excellent catalytic effect for the thermal decomposition of AP was observed by decreasing the decomposition temperature by 175 °C with single decomposing step. The fabricated chemical sensor based on green synthesized Mn3O4 NPs displayed high, reliable and reproducible sensitivity of ∼569.2 μA mM(-1) cm(-2) with reasonable limit of detection (LOD) of ∼22.1 μM and the response time of ∼10 s toward the detection of 2-butanone chemical. A relatively good linearity in the ranging from ∼20 to 160 μM was detected for Mn3O4 NPs electrode based 2-butanone chemical sensor. Copyright © 2016 Elsevier Inc. All rights reserved.
Lee, Chia-Jung; Hsueh, Thomas Y; Lin, Lie-Chwen; Tsai, Tung-Hu
2014-06-01
The stem with hook of Uncaria rhynchophylla (Chinese herbal name Gou-Teng) is a traditional Chinese medicine that has been ethnopharmacologically used to extinguish wind and clean interior heat. Rhynchophylline (RHY), a tetracyclic oxindole alkaloid isolated from U. rhynchophylla, displays significant antineuroinflammatory effects. However, there is no evidence to indicate that rhynchophylline can cross the blood-brain barrier and be detected in the brain. In this study, an in vivo microdialysis sampling method coupled with UPLC/MS/MS was employed for the continuous simultaneous monitoring of unbound RHY in rat blood and brain. The precursor ion → product ion transition at m/z 385.2 → 160.0 for rhynchophylline was monitored. A calibration curve gave good linearity (r>0.996) over the concentration range from 0.5 to 1000 ng/mL. The results demonstrated that rhynchophylline could be detected in the brain and plasma from 15 min to 6 h after its administration (1 or 10 mg/kg, i.v.). All the pharmacokinetic parameters of rhynchophylline in the brain and plasma were obtained. These results show that rhynchophylline can cross the blood-brain barrier and they provide useful clinical information. Copyright © 2014 John Wiley & Sons, Ltd.
Fluorescence turn-on sensing of trace cadmium ions based on EDTA-etched CdTe@CdS quantum dot.
Wang, Si-Nan; Zhu, Jian; Li, Xin; Li, Jian-Jun; Zhao, Jun-Wu
2018-05-01
Cadmium-caused environmental pollution and diseases have always been worldwide problems. Thus it is extremely urgent to establish a cheap, rapid, simple and selective detection method for trace cadmium in drinking water. In this study, a fluorescence "turn-on" method based on ethylene diamine tetraacetic acid (EDTA)-etched CdTe@CdS quantum dots (QDs) was designed to detect Cd 2+ . High resolution transmission electron microscopy (HRTEM) and X-ray photoelectron spectroscopy (XPS) were utilized for chemical and structural characterization of the as-prepared QDs. Based on chemical etching of EDTA on the surface of CdTe@CdS QDs, specific Cd 2+ recognition sites were produced, and then results in fluorescence quenching. The introduction of Cd 2+ could identify these sites and restore the fluorescence of the EDTA-QDs system. Under the optimum conditions, the nanoprobe shows a linear response range from 0.05 to 9 μM with a very low detection limit of 0.032 μM. In addition, the reported fluorescence probe in this work displays a good selectivity for trace Cd 2+ over other metal ions and an admirable practicability in real water samples. Copyright © 2018 Elsevier B.V. All rights reserved.
A wearable sensor based on CLYC scintillators
NASA Astrophysics Data System (ADS)
McDonald, Benjamin S.; Myjak, Mitchell J.; Zalavadia, Mital A.; Smart, John E.; Willett, Jesse A.; Landgren, Peter C.; Greulich, Christopher R.
2016-06-01
We have developed a wearable radiation sensor using Cs2LiYCl6:Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ∅ 2.5 × 2.5cm3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of gamma rays and neutrons. The total counts, anomaly detection metrics, and identified isotopes are displayed on a small screen. Users may leave the device in unattended mode to collect long-dwell energy spectra. The system stores up to 18 h of one-second data, including energy spectra, and may transfer the data to a remote computer via a wired or wireless connection. The prototype is 18 × 13 × 7.5cm3, weighs 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 h with the wireless link active, or 41 h with the wireless link disabled. In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.
Dhara, Keerthy; Ramachandran, T; Nair, Bipin G; Babu, T G Satheesh
2018-06-01
A highly sensitive nonenzymatic hydrogen peroxide (H2O2) sensor was fabricated using platinum nanoparticles decorated reduced graphene oxide (Pt/rGO) nanocomposite. The Pt/rGO nanocomposite was prepared by single-step chemical reduction method. Nanocomposite was characterized by various analytical techniques including Raman spectroscopy, X-ray diffraction, field emission scanning electron microscope and high-resolution transmission electron microscopy. Screen printed electrodes (SPEs) were fabricated and the nanocomposite was cast on the working area of the SPE. Cyclic voltammetry and amperometry demonstrated that the Pt/rGO/SPE displayed much higher electrocatalytic activity towards the reduction of H2O2 than the other modified electrodes. The sensor exhibited wide linear detection range (from 10 μM to 8 mM), very high sensitivity of 1848 μA mM-1 cm-2 and a lower limit of detection of 0.06 μM. The excellent performance of Pt/rGO/SPE sensor were attributed to the reduced graphene oxide being used as an effective matrix to load a number of Pt nanoparticles and the synergistic amplification effect of the two kinds of nanomaterials. Moreover, the sensor showed remarkable features such as good reproducibility, repeatability, long-term stability, and selectivity.
One-step synthesis of fluorescent carbon dots for sensitive and selective detection of hyperin.
Liu, Lizhen; Mi, Zhi; Hu, Qin; Li, Caiqing; Li, Xiaohua; Feng, Feng
2018-08-15
In this article, we presented a new rapid, sensitive and selective method for the determination of hyperin (Hyp) based on the fluorescence quenching of fluorescent carbon dots (CDs). The CDs were prepared by simply mixing an aqueous solution of citric acid with diphosphorus pentoxide. This one-step synthetic route is fast and simple with neither high temperature nor complicated synthesis steps is involved. When Hyp was added to CDs solution, the fluorescence intensity of the CDs significantly decreased. The CDs display high selectivity for Hyp over many potentially interfering substances. Under the optimized conditions, a good linear relationship between the fluorescence intensity ratio F o /F and the concentration of Hyp is obtained in a range of 0.22-55 µM with a detection limit (S/N = 3) of 78.3 nM. The method was successfully applied for the determination of Hyp in fufangmuji granules and human serum samples with recoveries in a range of 93.3-107.0%. This paper highlights the usefulness of CDs as an effective fluorescence probe for the Hyp detection due to its easy preparation, low-cost, excellent photostability, favorable biocompatibility and low cytotoxicity. Copyright © 2018 Elsevier B.V. All rights reserved.
Xie, Jian-De; Zhang, Houan
2017-01-01
This work outlines a synthetic strategy inducing the microwave-assisted synthesis of palladium (Pd) nanocrystals on a graphite sphere (GS) and reduced graphene oxide (rGO) supports, forming the Pd catalysts for non-enzymatic glucose oxidation reaction (GOR). The pulse microwave approach takes a short period (i.e., 10 min) to fast synthesize Pd nanocrystals onto a carbon support at 150 °C. The selection of carbon support plays a crucial role in affecting Pd particle size and dispersion uniformity. The robust design of Pd-rGO catalyst electrode displays an enhanced electrocatalytic activity and sensitivity toward GOR. The enhanced performance is mainly attributed to the synergetic effect that combines small crystalline size and two-dimensional conductive support, imparting high accessibility to non-enzymatic GOR. The rGO sheets serve as a conductive scaffold, capable of fast conducting electron. The linear plot of current response versus glucose concentration exhibits good correlations within the range of 1–12 mM. The sensitivity of the Pd-rGO catalyst is significantly enhanced by 3.7 times, as compared to the Pd-GS catalyst. Accordingly, the Pd-rGO catalyst electrode can be considered as a potential candidate for non-enzymatic glucose biosensor. PMID:28934104
Chu, Lanling; Deng, Siwei; Zhao, Renshan; Deng, Jianjun; Kang, Xuejun
2016-01-01
The objective of this study was to compare the adsorption/desorption of target compounds on homemade electrospun nanofibers, polystyrene (PS) nanofibers, acrylic resin (AR) nanofibers and PS-AR composite nanofibers with Tenax TA. Ten volatile organic compounds (VOCs) were analyzed by preconcentration onto different sorbents followed by desorption (thermal and solvent orderly) and analysis by capillary gas chromatography. In comparison to Tenax TA, the electrospun nanofibers displayed a significant advantage in desorption efficiency and adsorption selectivity. Stability studies were conducted as a comparative experiment between PS-AR nanofibers and Tenax TA using toluene as the model compound. No stability problems were observed upon storage of toluene on both PS-AR nanofibers and Tenax TA over 60 hours period when maintained in an ultra-freezer (−80°C). The nanofibers provided slightly better stability for the adsorbed analytes than Tenax TA under other storage conditions. In addition, the nanofibers also provided slightly better precision than Tenax TA. The quantitative adsorption of PS-AR nanofibers exhibited a good linearity, as evidenced by the 0.988–0.999 range of regression coefficients (R). These results suggest that for VOCs sampling the electrospun nanofibers can be a potential ideal adsorbent. PMID:27776140
Lipase-nanoporous gold biocomposite modified electrode for reliable detection of triglycerides.
Wu, Chao; Liu, Xueying; Li, Yufei; Du, Xiaoyu; Wang, Xia; Xu, Ping
2014-03-15
For triglycerides biosensor design, protein immobilization is necessary to create the interface between the enzyme and the electrode. In this study, a glassy carbon electrode (GCE) was modified with lipase-nanoporous gold (NPG) biocomposite (denoted as lipase/NPG/GCE). Due to highly conductive, porous, and biocompatible three-dimensional structure, NPG is suitable for enzyme immobilization. In cyclic voltammetry experiments, the lipase/NPG/GCE bioelectrode displayed surface-confined reaction in a phosphate buffer solution. Linear responses were obtained for tributyrin concentrations ranging from 50 to 250 mg dl(-1) and olive oil concentrations ranging from 10 to 200 mg dl(-1). The value of apparent Michaelis-Menten constant for tributyrin was 10.67 mg dl(-1) and the detection limit was 2.68 mg dl(-1). Further, the lipase/NPG/GCE bioelectrode had strong anti-interference ability against urea, glucose, cholesterol, and uric acid as well as a long shelf-life. For the detection of triglycerides in human serum, the values given by the lipase/NPG/GCE bioelectrode were in good agreement with those of an automatic biochemical analyzer. These properties along with a long self-life make the lipase/NPG/GCE bioelectrode an excellent choice for the construction of triglycerides biosensor. © 2013 Elsevier B.V. All rights reserved.
Wu, Chi-Ming; Chen, Yen-Hao; Dayananda, Kasala; Shiue, Tsun-Wei; Hung, Chen-Hsiung; Liaw, Wen-Feng; Chen, Po-Yu; Wang, Yun-Ming
2011-12-05
A colorless and non-fluorescent rhodamine derivative, rhodamine B hydrazide (RH), is applied to detect nitric oxide and form fluorescent rhodamine B (RB). The reaction mechanism of RH with NO is proposed in this study. The probe shows good stability over a broad pH range (pH>4). Furthermore, fluorescence intensity of RH displays an excellent linearity to the NO concentration and the detection limit is as low as 20 nM. A 1000-fold fluorescence turn-on from a dark background was observed. Moreover, the selectivity study indicated that the fluorescence intensity increasing in the presence of NO was significantly higher than those of other reactive oxygen/nitrogen species. In exogenously generated NO detection study, clear intracellular red fluorescence was observed in the presence of S-nitroso-N-acetyl-D,L-penicillamine (SNAP, a kind of NO releasing agent). In endogenously generated NO detection study, increasing incubation time of RH with lipopolysaccharied (LPS) pre-treated cells could obtain a highly fluorescent cell image. These cell imaging results demonstrated that RH can efficiently penetrate into Raw 264.7 cells and be used for detection of exogenously and endogenously generated nitric oxide. Copyright © 2011 Elsevier B.V. All rights reserved.
A 3D Chemically Modified Graphene Hydrogel for Fast, Highly Sensitive, and Selective Gas Sensor.
Wu, Jin; Tao, Kai; Guo, Yuanyuan; Li, Zhong; Wang, Xiaotian; Luo, Zhongzhen; Feng, Shuanglong; Du, Chunlei; Chen, Di; Miao, Jianmin; Norford, Leslie K
2017-03-01
Reduced graphene oxide (RGO) has proved to be a promising candidate in high-performance gas sensing in ambient conditions. However, trace detection of different kinds of gases with simultaneously high sensitivity and selectivity is challenging. Here, a chemiresistor-type sensor based on 3D sulfonated RGO hydrogel (S-RGOH) is reported, which can detect a variety of important gases with high sensitivity, boosted selectivity, fast response, and good reversibility. The NaHSO 3 functionalized RGOH displays remarkable 118.6 and 58.9 times higher responses to NO 2 and NH 3 , respectively, compared with its unmodified RGOH counterpart. In addition, the S-RGOH sensor is highly responsive to volatile organic compounds. More importantly, the characteristic patterns on the linearly fitted response-temperature curves are employed to distinguish various gases for the first time. The temperature of the sensor is elevated rapidly by an imbedded microheater with little power consumption. The 3D S-RGOH is characterized and the sensing mechanisms are proposed. This work gains new insights into boosting the sensitivity of detecting various gases by combining chemical modification and 3D structural engineering of RGO, and improving the selectivity of gas sensing by employing temperature dependent response characteristics of RGO for different gases.
Flexible ex vivo phantoms for validation of diffusion tensor tractography on a clinical scanner.
Watanabe, Makoto; Aoki, Shigeki; Masutani, Yoshitaka; Abe, Osamu; Hayashi, Naoto; Masumoto, Tomohiko; Mori, Harushi; Kabasawa, Hiroyuki; Ohtomo, Kuni
2006-11-01
The aim of this study was to develop ex vivo diffusion tensor (DT) flexible phantoms. Materials were bundles of textile threads of cotton, monofilament nylon, rayon, and polyester bunched with spiral wrapping bands and immersed in water. DT images were acquired on a 1.5-Tesla clinical magnetic resonance scanner using echo planar imaging sequences with 15 motion probing gradient directions. DT tractography with seeding and a line-tracking method was carried out by software originally developed on a PC-based workstation. We observed relatively high fractional anisotropy on the polyester phantom and were able to reconstruct tractography. Straight tracts along the bundle were displayed when it was arranged linearly. It was easy to bend arcuately or bifurcate at one end; and tracts followed the course of the bundle, whether it was curved or branched and had good agreement with direct visual observation. Tractography with the other fibers was unsuccessful. The polyester phantom revealed a diffusion anisotropic structure according to its shape and would be utilizable repeatedly under the same conditions, differently from living central neuronal system. It would be useful to validate DT sequences and to optimize an algorithm or parameters of DT tractography software. Additionally, the flexibility of the phantom would enable us to model human axonal projections.
Adiabatic corrections to density functional theory energies and wave functions.
Mohallem, José R; Coura, Thiago de O; Diniz, Leonardo G; de Castro, Gustavo; Assafrão, Denise; Heine, Thomas
2008-09-25
The adiabatic finite-nuclear-mass-correction (FNMC) to the electronic energies and wave functions of atoms and molecules is formulated for density-functional theory and implemented in the deMon code. The approach is tested for a series of local and gradient corrected density functionals, using MP2 results and diagonal-Born-Oppenheimer corrections from the literature for comparison. In the evaluation of absolute energy corrections of nonorganic molecules the LDA PZ81 functional works surprisingly better than the others. For organic molecules the GGA BLYP functional has the best performance. FNMC with GGA functionals, mainly BLYP, show a good performance in the evaluation of relative corrections, except for nonorganic molecules containing H atoms. The PW86 functional stands out with the best evaluation of the barrier of linearity of H2O and the isotopic dipole moment of HDO. In general, DFT functionals display an accuracy superior than the common belief and because the corrections are based on a change of the electronic kinetic energy they are here ranked in a new appropriate way. The approach is applied to obtain the adiabatic correction for full atomization of alcanes C(n)H(2n+2), n = 4-10. The barrier of 1 mHartree is approached for adiabatic corrections, justifying its insertion into DFT.
A wearable sensor based on CLYC scintillators
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, Benjamin S.; Myjak, Mitchell J.; Zalavadia, Mital A.
We developed a wearable radiation sensor using Cs 2LiYCl 6:Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collectmore » long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.« less
Linear flow dynamics near a T/NT interface
NASA Astrophysics Data System (ADS)
Teixeira, Miguel; Silva, Carlos
2011-11-01
The characteristics of a suddenly-inserted T/NT interface separating a homogeneous and isotropic shear-free turbulence region from a non-turbulent flow region are investigated using rapid distortion theory (RDT), taking full account of viscous effects. Profiles of the velocity variances, TKE, viscous dissipation rate, turbulence length scales, and pressure statistics are derived, showing very good agreement with DNS. The normalized inviscid flow statistics at the T/NT interface do not depend on the form of the assumed TKE spectrum. In the non-turbulent region, where the flow is irrotational (except within a thin viscous boundary layer), the dissipation rate decays as z-6, where z is distance from the T/NT interface. The mean pressure exhibits a decrease towards the turbulence due to the associated velocity fluctuations, consistent with the generation of a mean entrainment velocity. The vorticity variance and dissipation rate display large maxima at the T/NT interface due to the existing inviscid discontinuities of the tangential velocity, and these maxima are quantitatively related to the thickness of the viscous boundary layer (VBL). At equilibrium, RDT suggests that the thickness of the T/NT interface scales on the Kolmogorov microscale. We acknowledge the financial support of FCT under Project PTDC/EME-MFE/099636/2008.
How much crosstalk can be allowed in a stereoscopic system at various grey levels?
NASA Astrophysics Data System (ADS)
Shestak, Sergey; Kim, Daesik; Kim, Yongie
2012-03-01
We have calculated a perceptual threshold of stereoscopic crosstalk on the basis of mathematical model of human vision sensitivity. Instead of linear model of just noticeable difference (JND) known as Weber's law we applied nonlinear Barten's model. The predicted crosstalk threshold varies with the background luminance. The calculated values of threshold are in a reasonable agreement with known experimental data. We calculated perceptual threshold of crosstalk for various combinations of the applied grey level. This result can be applied for the assessment of grey-to-grey crosstalk compensation. Further computational analysis of the applied model predicts the increase of the displayable image contrast with reduction of the maximum displayable luminance.
NASA Technical Reports Server (NTRS)
Bekey, G. A.
1971-01-01
Studies are summarized on the application of advanced analytical and computational methods to the development of mathematical models of human controllers in multiaxis manual control systems. Specific accomplishments include the following: (1) The development of analytical and computer methods for the measurement of random parameters in linear models of human operators. (2) Discrete models of human operator behavior in a multiple display situation were developed. (3) Sensitivity techniques were developed which make possible the identification of unknown sampling intervals in linear systems. (4) The adaptive behavior of human operators following particular classes of vehicle failures was studied and a model structure proposed.
NASA Astrophysics Data System (ADS)
Rychnovsky, Steve; Gilbreath, G. C.; Zavriyev, A.
1996-10-01
Simultaneous measurements of the photorefractive and the absorptive grating gain components in GaAs:EL2 are made and are shown to display qualitative behavior consistent with linearized solutions of a two-carrier rate equation model. These two components, together with the linear absorption coefficient, permit determination of four independent material parameters, e.g., the ionized and the nonionized EL2 densities, the hole photoionization cross section ( sigma h), and the electro-optic coefficient (r41). Data obtained at optical wavelengths of 0.96 and 1.06 mu m indicate that sigma h and r41 are larger than published values. .
Nanoprobe diffusion in entangled polymer solutions: Linear vs. unconcatenated ring chains
NASA Astrophysics Data System (ADS)
Nahali, Negar; Rosa, Angelo
2018-05-01
We employ large-scale molecular dynamics computer simulations to study the problem of nanoprobe diffusion in entangled solutions of linear polymers and unknotted and unconcatenated circular (ring) polymers. By tuning both the diameter of the nanoprobe and the density of the solution, we show that nanoprobes of diameter smaller than the entanglement distance (tube diameter) of the solution display the same (Rouse-like) behavior in solutions of both polymer architectures. Instead, nanoprobes with larger diameters appear to diffuse markedly faster in solutions of rings than in solutions of linear chains. Finally, by analysing the distribution functions of spatial displacements, we find that nanoprobe motion in rings' solutions shows both Gaussian and ergodic behaviors, in all regimes considered, while, in solutions of linear chains, nanoprobes exceeding the size of the tube diameter show a transition to non-Gaussian and non-ergodic motion. Our results emphasize the role of chain architecture in the motion of nanoprobes dispersed in polymer solutions.
Approximate formulas for elasticity of the Tornquist functions and some their advantages
NASA Astrophysics Data System (ADS)
Issin, Meyram
2017-09-01
In this article functions of demand for prime necessity, second necessity and luxury goods depending on the income are considered. These functions are called Tornquist functions. By means of the return model the demand for prime necessity goods and second necessity goods are approximately described. Then on the basis of a method of the smallest squares approximate formulas for elasticity of these Tornquist functions are received. To receive an approximate formula for elasticity of function of demand for luxury goods, the linear asymptotic formula is constructed for this function. Some benefits of approximate formulas for elasticity of Tornquist functions are specified.
Synthesis, characterization and calculated non-linear optical properties of two new chalcones
NASA Astrophysics Data System (ADS)
Singh, Ashok Kumar; Saxena, Gunjan; Prasad, Rajendra; Kumar, Abhinav
2012-06-01
Two new chalcones viz 3-(4-(benzyloxy)phenyl)-1-(2-hydroxyphenyl)prop-2-en-1-one (1) and 3-(4-chlorophenyl)-1-(2-hydroxyphenyl)prop-2-en-1-one (2) have been prepared and characterized by micro analyses, 1H NMR, IR, UV-Vis spectroscopy and single crystal X-ray. The first static hyperpolarizability (β) for both the compounds has been investigated by density functional theory (DFT). Also, the solvent-induced effects on the non-linear optical properties (NLO) were studied by using self-consistent reaction field (SCRF) method. As the solvent polarity increases, the β value increases monotonically. The electronic absorption bands of both 1 and 2 have been assigned by time dependent density functional theory (TD-DFT). Both the compounds displayed better non-linear optical (NLO) responses than the standard p-nitroaniline (pNA).
NASA Astrophysics Data System (ADS)
Cano-Lara, Miroslava; Severiano-Carrillo, Israel; Trejo-Durán, Mónica; Alvarado-Méndez, Edgar
2017-09-01
In this work, we present a study of non-linear optical response in thin films elaborated with Gelite Bloom and extract of Hibiscus Sabdariffa. Non-linear refraction and absorption effects were studied experimentally (Z-scan technique) and numerically, by considering the transmittance as non-linear absorption and refraction contribution. We observe large phase shifts to far field, and diffraction due to self-phase modulation of the sample. Diffraction and self-diffraction effects were observed as time function. The aim of studying non-linear optical properties in thin films is to eliminate thermal vortex effects that occur in liquids. This is desirable in applications such as non-linear phase contrast, optical limiting, optics switches, etc. Finally, we find good agreement between experimental and theoretical results.
Dry etching of chrome for photomasks for 100-nm technology using chemically amplified resist
NASA Astrophysics Data System (ADS)
Mueller, Mark; Komarov, Serguie; Baik, Ki-Ho
2002-07-01
Photo mask etching for the 100nm technology node places new requirements on dry etching processes. As the minimum-size features on the mask, such as assist bars and optical proximity correction (OPC) patterns, shrink down to 100nm, it is necessary to produce etch CD biases of below 20nm in order to reproduce minimum resist features into chrome with good pattern fidelity. In addition, vertical profiles are necessary. In previous generations of photomask technology, footing and sidewall profile slope were tolerated, since this dry etch profile was an improvement from wet etching. However, as feature sizes shrink, it is extremely important to select etch processes which do not generate a foot, because this will affect etch linearity and also limit the smallest etched feature size. Chemically amplified resist (CAR) from TOK is patterned with a 50keV MEBES eXara e-beam writer, allowing for patterning of small features with vertical resist profiles. This resist is developed for raster scan 50 kV e-beam systems. It has high contrast, good coating characteristics, good dry etch selectivity, and high environmental stability. Chrome etch process development has been performed using Design of Experiments to optimize parameters such as sidewall profile, etch CD bias, etch CD linearity for varying sizes of line/space patterns, etch CD linearity for varying sizes of isolated lines and spaces, loading effects, and application to contact etching.
NASA Technical Reports Server (NTRS)
Breckinridge, J. B.; Page, N. A.; Rodgers, J. M.
1985-01-01
Efficient linear dispersive element for spectrometer instruments achieved using several different glasses in multiple-element prism. Good results obtained in both two-and three-element prisms using variety of different glass materials.
Entropy-based goodness-of-fit test: Application to the Pareto distribution
NASA Astrophysics Data System (ADS)
Lequesne, Justine
2013-08-01
Goodness-of-fit tests based on entropy have been introduced in [13] for testing normality. The maximum entropy distribution in a class of probability distributions defined by linear constraints induces a Pythagorean equality between the Kullback-Leibler information and an entropy difference. This allows one to propose a goodness-of-fit test for maximum entropy parametric distributions which is based on the Kullback-Leibler information. We will focus on the application of the method to the Pareto distribution. The power of the proposed test is computed through Monte Carlo simulation.
Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M
2012-01-01
In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.
Simple estimation of linear 1+1 D tsunami run-up
NASA Astrophysics Data System (ADS)
Fuentes, M.; Campos, J. A.; Riquelme, S.
2016-12-01
An analytical expression is derived concerning the linear run-up for any given initial wave generated over a sloping bathymetry. Due to the simplicity of the linear formulation, complex transformations are unnecessay, because the shoreline motion is directly obtained in terms of the initial wave. This analytical result not only supports maximum run-up invariance between linear and non-linear theories, but also the time evolution of shoreline motion and velocity. The results exhibit good agreement with the non-linear theory. The present formulation also allows computing the shoreline motion numerically from a customised initial waveform, including non-smooth functions. This is useful for numerical tests, laboratory experiments or realistic cases in which the initial disturbance might be retrieved from seismic data rather than using a theoretical model. It is also shown that the real case studied is consistent with the field observations.
Ion radial diffusion in an electrostatic impulse model for stormtime ring current formation
NASA Technical Reports Server (NTRS)
Chen, Margaret W.; Schulz, Michael; Lyons, Larry R.; Gorney, David J.
1992-01-01
Two refinements to the quasi-linear theory of ion radial diffusion are proposed and examined analytically with simulations of particle trajectories. The resonance-broadening correction by Dungey (1965) is applied to the quasi-linear diffusion theory by Faelthammar (1965) for an individual model storm. Quasi-linear theory is then applied to the mean diffusion coefficients resulting from simulations of particle trajectories in 20 model storms. The correction for drift-resonance broadening results in quasi-linear diffusion coefficients with discrepancies from the corresponding simulated values that are reduced by a factor of about 3. Further reductions in the discrepancies are noted following the averaging of the quasi-linear diffusion coefficients, the simulated coefficients, and the resonance-broadened coefficients for the 20 storms. Quasi-linear theory provides good descriptions of particle transport for a single storm but performs even better in conjunction with the present ensemble-averaging.
The determination of third order linear models from a seventh order nonlinear jet engine model
NASA Technical Reports Server (NTRS)
Lalonde, Rick J.; Hartley, Tom T.; De Abreu-Garcia, J. Alex
1989-01-01
Results are presented that demonstrate how good reduced-order models can be obtained directly by recursive parameter identification using input/output (I/O) data of high-order nonlinear systems. Three different methods of obtaining a third-order linear model from a seventh-order nonlinear turbojet engine model are compared. The first method is to obtain a linear model from the original model and then reduce the linear model by standard reduction techniques such as residualization and balancing. The second method is to identify directly a third-order linear model by recursive least-squares parameter estimation using I/O data of the original model. The third method is to obtain a reduced-order model from the original model and then linearize the reduced model. Frequency responses are used as the performance measure to evaluate the reduced models. The reduced-order models along with their Bode plots are presented for comparison purposes.
Investigating multiphoton phenomena using nonlinear dynamics
NASA Astrophysics Data System (ADS)
Huang, Shu
Many seemingly simple systems can display extraordinarily complex dynamics which has been studied and uncovered through nonlinear dynamical theory. The leitmotif of this thesis is changing phase-space structures and their (linear or non-linear) stabilities by adding control functions (which act on the system as external perturbations) to the relevant Hamiltonians. These phase-space structures may be periodic orbits, invariant tori or their stable and unstable manifolds. One-electron systems and diatomic molecules are fundamental and important staging ground for new discoveries in nonlinear dynamics. In past years, increasing emphasis and effort has been put on the control or manipulation of these systems. Recent developments of nonlinear dynamical tools can provide efficient ways of doing so. In the first subtopic of the thesis, we are adding a control function to restore tori at prescribed locations in phase space. In the remainder of the thesis, a control function with parameters is used to change the linear stability of the periodic orbits which govern the processes in question. In this thesis, we report our theoretical analyses on multiphoton ionization of Rydberg atoms exposed to strong microwave fields and the dissociation of diatomic molecules exposed to bichromatic lasers using nonlinear dynamical tools. This thesis is composed of three subtopics. In the first subtopic, we employ local control theory to reduce the stochastic ionization of hydrogen atom in a strong microwave field by adding a relatively small control term to the original Hamiltonian. In the second subtopic, we perform periodic orbit analysis to investigate multiphoton ionization driven by a bichromatic microwave field. Our results show quantitative and qualitative agreement with previous studies, and hence identify the mechanism through which short periodic orbits organize the dynamics in multiphoton ionization. In addition, we achieve substantial time savings with this approach. In the third subtopic we extend our periodic orbit analysis to the dissociation of diatomic molecules driven by a bichromatic laser. In this problem, our results based on periodic orbit analysis again show good agreement with previous work, and hence promise more potential applications of this approach in molecular physics.
NASA Astrophysics Data System (ADS)
Widyastuti, E.; Puspitasari Schonherr, M. F.; Masruroh, A.; Anggraeni, R. A.; Nisak, Y. K.; Mursidah, S.
2018-03-01
Salmonella is pathogenic bacteria that caused foodborne diseases which being called Salmonellosis. Prevalence of Salmonellosis that being caused by Salmonella thypimurium in Indonesia is quite high. However, detection of Salmonella bacteria in food still limited, complicated, and required a lot time. Sensitive optical assay for Salmonella thypimurium paper based detection has been developed by integrating sandwich assay between antibody-antigen complex and alkaline phosphatase enzyme that produce visible bluish-purple colour with presence of NBT-BCIP substrate. The results showed that Limit of Quantitation of detection is 105 CFU mL-1 with detection time 15 minutes. Linearity test between Colour intensity that produced from Salmonella concentration presence on samples showed that detection has good linearity. Selectivity test exhibited excellent sensitivity with good discrimination against Escherichia coli.
An ANSERLIN array for mobile satellite applications
NASA Technical Reports Server (NTRS)
Colomb, F. Y.; Kunkee, D. B.; Mayes, P. E.; Smith, D. W.; Jamnejad, V.
1990-01-01
Design, analysis, construction, and test of linear arrays of ANSERLIN (annular sector, radiating line) elements are reported and discussed. Due to feeding simplicity and easy construction as well as good CP performance, a planar array composed of a number of such linear arrays each producing a shaped beam tilted in elevation, is a good candidate as a vehicle-mounted mechanically steered antenna for mobile satellite applications. A single level construction technique was developed that makes this type of array very cost competitive with other low-profile arrays. An asymmetric 19.5 inch long four-element array was fabricated and tested with reasonable performance. A smaller five-element symmetric array (16 inch long) was also designed and tested capable of operating in either sense of circular polarization. Efforts were made to successfully reduce this effect.
On the Use of Linearized Euler Equations in the Prediction of Jet Noise
NASA Technical Reports Server (NTRS)
Mankbadi, Reda R.; Hixon, R.; Shih, S.-H.; Povinelli, L. A.
1995-01-01
Linearized Euler equations are used to simulate supersonic jet noise generation and propagation. Special attention is given to boundary treatment. The resulting solution is stable and nearly free from boundary reflections without the need for artificial dissipation, filtering, or a sponge layer. The computed solution is in good agreement with theory and observation and is much less CPU-intensive as compared to large-eddy simulations.
Antibacterial activity of head-to-head bis-benzimidazoles.
Moreira, Joao B; Mann, John; Neidle, Stephen; McHugh, Timothy D; Taylor, Peter W
2013-10-01
Symmetric bis-benzimidazole (BBZ) conjugates were profiled for activity against a range of Gram-positive and Gram-negative bacteria. para-Substituted ethoxy, amino and methoxy derivatives displayed potent bacteriostatic activity against meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, streptococci and Listeria monocytogenes. Moderate to good activity was also found against mycobacteria; two compounds were strongly active against logarithmic phase and hypoxia-induced latent Mycobacterium tuberculosis. No compound displayed significant activity towards Gram-negative bacteria. Only high concentrations of antibacterial BBZs showed cytotoxic effects towards fibroblasts, and the most active compound was well tolerated by zebrafish embryos. Copyright © 2013 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Attenni, Barbara; Ontoria, Jesus M; Cruz, Jonathan C; Rowley, Michael; Schultz-Fademrecht, Carsten; Steinkühler, Christian; Jones, Philip
2009-06-01
Histone deacetylase (HDAC) inhibition causes hyperacetylation of histones leading to differentiation, growth arrest and apoptosis of malignant cells, representing a new strategy in cancer therapy. Many of the known HDAC inhibitors (HDACi) that are in clinical trials possess a hydroxamic acid, that is a strong Zn(2+) binding group, thereby inhibiting some of the class I and class II isoforms. Herein we describe the identification of a selective class I HDAC inhibitor bearing a primary carboxamide moiety as zinc binding group. This HDACi displays good antiproliferative activity against multiple cancer cell lines, and demonstrates efficacy in a xenograft model comparable to vorinostat.
Computer-aided design studies of the homopolar linear synchronous motor
NASA Astrophysics Data System (ADS)
Dawson, G. E.; Eastham, A. R.; Ong, R.
1984-09-01
The linear induction motor (LIM), as an urban transit drive, can provide good grade-climbing capabilities and propulsion/braking performance that is independent of steel wheel-rail adhesion. In view of its 10-12 mm airgap, the LIM is characterized by a low power factor-efficiency product of order 0.4. A synchronous machine offers high efficiency and controllable power factor. An assessment of the linear homopolar configuration of this machine is presented as an alternative to the LIM. Computer-aided design studies using the finite element technique have been conducted to identify a suitable machine design for urban transit propulsion.
NASA Astrophysics Data System (ADS)
Pradanti, Paskalia; Hartono
2018-03-01
Determination of insulin injection dose in diabetes mellitus treatment can be considered as an optimal control problem. This article is aimed to simulate optimal blood glucose control for patient with diabetes mellitus. The blood glucose regulation of diabetic patient is represented by Ackerman’s Linear Model. This problem is then solved using dynamic programming method. The desired blood glucose level is obtained by minimizing the performance index in Lagrange form. The results show that dynamic programming based on Ackerman’s Linear Model is quite good to solve the problem.
1988-01-01
for hydrauine, MMH and UDMH are 4.78 x 10-6, 10.2 x 10Ś, and 3.19 x 10-6 aecŕ, respectively. Plots of the log(area) versus time were linear and...followed first-order kinetics except for hydrauine, for which a non- linear portion was observed in the first 6 to 8 hours. This portion of the decay...As a result, the prototype flow reactor can be represented to good approximation by a linear combination of point source solutions (Reference 19). The
Mu, Xihui; Tong, Zhaoyang; Huang, Qibin; Liu, Bing; Liu, Zhiwei; Hao, Lanqun; Dong, Hua; Zhang, Jinping; Gao, Chuan
2016-01-01
Using the multiple advantages of the ultra-highly sensitive electrochemiluminescence (ECL) technique, Staphylococcus protein A (SPA) functionalized gold-magnetic nanoparticles and phage displayed antibodies, and using gold-magnetic nanoparticles coated with SPA and coupled with a polyclonal antibody (pcAb) as magnetic capturing probes, and Ru(bpy)32+-labeled phage displayed antibody as a specific luminescence probe, this study reports a new way to detect ricin with a highly sensitive and specific ECL immunosensor and amplify specific detection signals. The linear detection range of the sensor was 0.0001~200 µg/L, and the limit of detection (LOD) was 0.0001 µg/L, which is 2500-fold lower than that of the conventional ELISA technique. The gold-magnetic nanoparticles, SPA and Ru(bpy)32+-labeled phage displayed antibody displayed different amplifying effects in the ECL immunosensor and can decrease LOD 3-fold, 3-fold and 20-fold, respectively, compared with the ECL immunosensors without one of the three effects. The integrated amplifying effect can decrease the LOD 180-fold. The immunosensor integrates the unique advantages of SPA-coated gold-magnetic nanoparticles that improve the activity of the functionalized capturing probe, and the amplifying effect of the Ru(bpy)32+-labeled phage displayed antibodies, so it increases specificity, interference-resistance and decreases LOD. It is proven to be well suited for the analysis of trace amounts of ricin in various environmental samples with high recovery ratios and reproducibility. PMID:26927130
Thermoreversibly Cross-Linked EPM Rubber Nanocomposites with Carbon Nanotubes
Criscitiello, Francesco; van Essen, Machiel; Araya-Hermosilla, Rodrigo; Migliore, Nicola; Lenti, Mattia; Raffa, Patrizio
2018-01-01
Conductive rubber nanocomposites were prepared by dispersing conductive nanotubes (CNT) in thermoreversibly cross-linked ethylene propylene rubbers grafted with furan groups (EPM-g-furan) rubbers. Their features were studied with a strong focus on conductive and mechanical properties relevant for strain-sensor applications. The Diels-Alder chemistry used for thermoreversible cross-linking allows for the preparation of fully recyclable, homogeneous, and conductive nanocomposites. CNT modified with compatible furan groups provided nanocomposites with a relatively large tensile strength and small elongation at break. High and low sensitivity deformation experiments of nanocomposites with 5 wt % CNT (at the percolation threshold) displayed an initially linear sensitivity to deformation. Notably, only fresh samples displayed a linear response of their electrical resistivity to deformations as the resistance variation collapsed already after one cycle of elongation. Notwithstanding this mediocre performance as a strain sensor, the advantages of using thermoreversible chemistry in a conductive rubber nanocomposite were highlighted by demonstrating crack-healing by welding due to the joule effect on the surface and the bulk of the material. This will open up new technological opportunities for the design of novel strain-sensors based on recyclable rubbers. PMID:29360772
Individual predictions of eye-movements with dynamic scenes
NASA Astrophysics Data System (ADS)
Barth, Erhardt; Drewes, Jan; Martinetz, Thomas
2003-06-01
We present a model that predicts saccadic eye-movements and can be tuned to a particular human observer who is viewing a dynamic sequence of images. Our work is motivated by applications that involve gaze-contingent interactive displays on which information is displayed as a function of gaze direction. The approach therefore differs from standard approaches in two ways: (1) we deal with dynamic scenes, and (2) we provide means of adapting the model to a particular observer. As an indicator for the degree of saliency we evaluate the intrinsic dimension of the image sequence within a geometric approach implemented by using the structure tensor. Out of these candidate saliency-based locations, the currently attended location is selected according to a strategy found by supervised learning. The data are obtained with an eye-tracker and subjects who view video sequences. The selection algorithm receives candidate locations of current and past frames and a limited history of locations attended in the past. We use a linear mapping that is obtained by minimizing the quadratic difference between the predicted and the actually attended location by gradient descent. Being linear, the learned mapping can be quickly adapted to the individual observer.
Synthesis and luminescence behavior of SrGd1.76Eu0.24O4 host for display and dosimetric applications
NASA Astrophysics Data System (ADS)
Singh, Jyoti; Manam, J.; Singh, Fouran
2018-05-01
Novel SrGd1.76Eu0.24O4 materials were synthesized by conventional high-temperature solid-state reaction method in air ambiance. The structural and luminescence properties of as-prepared phosphors were explored by XRD, FESEM, TEM, PL and TL techniques. The confirmation of orthorhombic phase formation was obtained by XRD studies. The agglomerated ginger-like morphology of as-synthesized SrGd1.76Eu0.24O4 samples was unfolded by FESEM and TEM studies. Upon 276 and 395 nm UV excitation, SrGd1.76Eu0.24O4 phosphors showed intense red emission. The TL glow curve of SrGd1.76Eu0.24O4 irradiated with γ-rays exhibits two well-resolved peaks at 393 K and 598 K having a shoulder at 537 K. Linearity in a wide dose range 500 Gy-3 kGy are observed in the as-formed SrGd1.76Eu0.24O4 samples. Intense red emission, linear dose response and high reproducibility of SrGd1.76Eu0.24O4 samples broadly indicated its suitability for display and TL dosimetry applications.
High rates of PTSD treatment dropout: A possible red herring?
Szafranski, Derek D; Smith, Brian N; Gros, Daniel F; Resick, Patricia A
2017-04-01
Few studies have examined symptom change among dropouts from posttraumatic stress disorder (PTSD) treatment. However, dropout is widely considered a negative event needing to be addressed. The present study investigated PTSD and depression symptom change in patients with PTSD who discontinued psychotherapy. Female civilians (n=321) diagnosed with PTSD participated in two randomized clinical trials examining PTSD treatment outcomes. Of those, 53 were identified as dropouts and included in this study. Symptom change was assessed by clinically significant change (CSC) criteria and symptom end-state criteria. Results demonstrated that considerable proportions of participants (35.85-55.56%) displayed significant improvement and/or met good end-state criteria for PTSD and depression. Results also revealed that participants who displayed symptom improvement were younger, attended more treatment sessions, were married or partnered, and had higher annual household income. Although preliminary, these findings contradict belief that treatment dropouts do not display symptom improvement. Published by Elsevier Ltd.